Digital Monitoring PC0136 DIGITAL TRANSMISSION SYSTEM User Manual

Digital Monitoring Products Inc DIGITAL TRANSMISSION SYSTEM Users Manual

Users Manual

Download: Digital Monitoring PC0136 DIGITAL TRANSMISSION SYSTEM User Manual
Mirror Download [FCC.gov]Digital Monitoring PC0136 DIGITAL TRANSMISSION SYSTEM User Manual
Document ID1638392
Application ID2S1dlL0g0+6RhPSu0CFGjQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize70.98kB (887212 bits)
Date Submitted2012-02-09 00:00:00
Date Available2012-02-09 00:00:00
Creation Date2012-02-14 08:55:45
Producing SoftwareAdobe PDF Library 9.9
Document Lastmod2012-02-14 08:55:52
Document TitleUsers Manual
Document CreatorAdobe InDesign CS5.5 (7.5.2)

INSTALLATION GUIDE
734W Wiegand Interface Module
Description
The 734W Wiegand Interface Module allows you to add WiFi network access control capability to XR100/XR500 panels using
proximity or mag-stripe card readers. The 734W provides a fast, safe and secure connection to your local WiFi network
for AES encrypted TCP communication with the control panel and allows fast verification of user codes presented at the
reader for door access. The 734W operates at 12/24 Vdc from the power supply supporting the magnetic lock or doorstrike at the door and provides a 10 Amp Form C relay contact for lock control. Four input zones are provided to allow
connection of nearby burglary devices. For local annunciation, a programmable speaker and a variety of switched ground
annunciators are provided to connect to
sounders. In addition, the 734W provides LEDs
to indicate door strike, Wiegand inputs, and
power to the module.
The 734W provides a keypad programming
connection to use a standard DMP LCD keypad
for initial WiFi network setup. Programming
can be completed using the keypad or from the
XR100/XR500 panel.
Mounting the 734W
The 734W ships installed in a decorative, highimpact plastic housing that mounts directly
to walls, backboards, or other flat surfaces.
For easy installation, the 734W housing back
and ends have wire entrances. The bottom
contains multiple screw holes for mounting on
single-gang switch boxes. It is recommended
to mount the 734W near the protected door.
Magnetic Lock and Door Strike Wiring
Figure 1: 734W Wiegand Interface Module
You can control door strikes and magnetic locks by using the Form C relay on the 734W module. Use an additional power
supply to power door strikes and magnetic locks. Refer to Figures 2 and 3 for wiring information.
Figure 2: 734W Magnetic Lock Wiring
Figure 3: 734W Door Strike Wiring
12/24 VDC Power
Power to the 734W module can be provided by a Listed 12 or 24 VDC power source connected to the J27 terminal block.
NO/C/NC (Dry Contact Relay)
The 734W provides a Form C (SPDT) relay for controlling door strikes or magnetic locks. The three relay terminals marked
NO C NC allow you to connect the device wiring to the relay for module control. See Figures 2 and 3 for proper door strike
and magnetic lock wiring.
The Form C relay draws up to 35mA of current and its contacts are rated for 10 Amps (resistive) at 12/24 VDC.
When connecting multiple locks to the Form C relay, the total current for all locks cannot exceed 10 Amps. If the total
current for all locks exceeds 10 Amps, problems may arise and an isolation relay may be needed.
See the Isolation Relay section for information.
Install the 333 Suppressor
One Model 333 Suppressor is included with
the 734W module. Install the suppressor
across the 734W Common (C) and Normally
Open (NO) or Normally Closed (NC)
terminals.
If the device being controlled by the relay is
connected to the NO and C terminals, install
the suppressor on the NO and C terminals.
Conversely, if the device is connected to
the NC and C terminals, install the 333
Suppressor on NC and C terminals.
The suppressor wire is non-polarized. Install
the suppressor as shown in Figure 4.
Isolation Relay
Figure 4: Model 333 Installation on the 734W Module
The Form C Relay can control a device that draws less than 10 Amps of current. If a device draws more than 10 Amp of
current, or the sum of all devices controlled by the Form C Relay exceeds 10 Amps, an isolation relay must be used. Refer to
Figures 5 and 6 for isolation relay wiring.
Figure 5: Isolation Relay with Magnetic Lock
Figure 6: Isolation Relay with Door Strike
Connection to Reader
The 734W provides direct 12/24 VDC, 200mA output to
the reader on the J9 Red terminal connection.
Figure 7 shows a reader with wire colors Red, White,
Green, and Black. The wire colors may be different for
the reader being installed. Connect the reader wires to
J9 terminals 1, 2, 3, and 4. As shown in Figure 7, the
Green wire carries D0, or Data Zero, and the White wire
carries D1, or Data One. The Red wire carries 12/24
VDC, 200mA power limited output and the Black wire is
ground.
Status LEDs
Figure 7: Card Reader Wiring
The 734W provides two status LEDs. See Figure 1 for locations of the LEDs.
• The Red LED turns on for the duration of the door strike.
• The Yellow LED turns on for one second to indicate a Wiegand read.
• The Green LED is constant to indicate power.
Digital Monitoring Products
734W Installation Guide
Zone Terminals
Terminals 5-11 on J9 connect grounded zones 1 through 3. These zones
have a grounded side and cannot be used for fire-initiating devices. Zones
2 and 3 can also be used for access control with Zone 2 providing a bypass
option and Zone 3 providing Request to Exit functionality. Zone 4 terminals
provide a non-powered Class B, Style A zone. Use the supplied, DMP
Model 311 1K Ohm End-of-Line resistors on each zone. Refer to the panel
programming guide for programming instructions.
Zone #
Recommended Device
Any burglary device
Door Contact
REX (PIR or Button)
Any device
Residential Fire Devices?
No
No
No
Yes
Figure 8: 734W Zone Terminals
Annunciator Header
The 4-pin J26 header located on the far right of the circuit board is used to wire the Armed Status, Remote Annunciation,
and the Remote LED Control. The open collectors will supply a ground for a
maximum current of 50mA @ 30 VDC. Connect a Model 300 4-wire harness to
Remote LED Control
the 4-pin header for connection of the following indicators:
Remote Audible Annunciator
Armed Status Output
--AS (Armed Status)
Armed Status provides an unsupervised switched ground for a visual or audible
Output 2
armed status indicator that turns on when the burglary areas are armed, such
as SYSTEM ON or ALL SYSTEM ON. Connect the wire from the 4-wire harness to
Output 1
an Armed Status output.
--RA (Remote Annunciation)
Remote Annunciation provides an unsupervised switched ground for a remote
annunciator that turns on when the Model 734W on-board piezo turns on.
Figure 9: 734W Annunicator Outputs
Connect the wire from the 4-wire harness to a remote annunciator. The
remote annunciator silences when the RA restores. The remote annunciator (RA) switched ground will operate even if the
speaker is programmed not to operate.
--LC (Remote LED Control)
Remote LED Control provides an unsupervised switched ground for a visual indicator that turns on when the Model 734W
relay activates. Connect the wire from the 4-wire harness to an LED. The LED turns on for the duration the door strike
relay is on. HID readers optionally provide a connection for LED reader control.
Auxiliary Outputs 1 & 2
The 734W controls Auxiliary Outputs 1 and 2 when the Activate Zone 2 Bypass programming option is enabled and the Zone
2 Bypass Time is set. When the door contact (Zone 2) is opened while the door strike is
Form C Relays (J2)
Output Color Code–Model 431 Harness
activated, the Zone 2 Bypass Time starts. If the door has not closed at the end of the timer,
Output 2 N/O Orange/White
Aux Output 1 is turned on and the timer starts again. If the door is still open at the end of the Output 2 Com White/Gray
Output 2 N/C Violet/White
second timer, Aux Output 2 is turned on. Aux Outputs 1 and 2 turn off when the door contact
1 N/O Orange
is closed. Use the Model 431 Relay Harness for connection of Output 1 and Output 2 as shown Output
Output 1 Com Gray
in Table 1.
Output 1 N/C Violet
Reset Header
Table 1: Harness Wiring
The reset header is located just above and to the right of the WiFi network connector (see Figure 1) and is used to reset
the 734W module. To reset the module when first installing the system, install the reset jumper before applying power to
the module. After connecting the power, remove the reset jumper.
To reset the module while the system is operational, for example, prior to reprogramming, install the reset jumper
without powering down the system. Remove the reset jumper after one or two seconds.
PROG (Programming)
The 734W module is programmable from a 32-character keypad set to address one. For 12 Volt applications, connect the
keypad to the module using a Model 330 4-wire harness.
For 24 Volt applications, connect the keypad to the module using the included WR-0235 4-wire programming harness with
in-line resistor.
Do not connect a keypad using a Model 330 harness if using a 24 volt power supply! Damage to the keypad
could occur.
While programming the 734W module with a keypad, advance to the next programming option by pressing the CMD key.
Return to the previous programming option or erase an incorrect entry by pressing the Back Arrow key. Make a selection
by pressing the Select key below the option you wish to select. While in programming mode no 734W communication with
the panel can occur.
734W Installation Guide
Digital Monitoring Products
734W
VER vvv mm/dd/yy
734W
ZONE: 1 -OKAY
734W DOOR
ZONE: 2 -OPEN
Version Display
When you connect the keypad to the 734W module, the version number and release 		
date display.
• Press keys 1, 2, 3, or 4 then the CMD key to show zone status of that zone.
• Press CMD key to enter the Diagnostic Menu.
• Press 6653 (PROG) then CMD to enter the Programming Menu.
Zone Status Display
The status of the entered zone number displays. To display another zone, enter the 		
zone number followed by the CMD key.
734W REX
ZONE: 3 -SHORT
MENU?
NO YES
Diagnostic Menu
Select YES to display the Panel Communication Connect Status display. Select NO to 		
return to Version Display.
CONNECT STATUS
Connect Status
CONNECT STATUS
NOT CONNECTED
Not Connected: The 734W cannot connect to the panel on the WiFi network.
To display the connection status of the 734W to the panel, select any top row key.
CONNECT STATUS
BAD PASSPHRASE
Bad Passphrase: The passphrase programmed in the 734W device does not match the 		
passphrase programmed in the panel.
CONNECT STATUS
DEVICE NOT PROG
Device Not Programmed: The device number programmed in the 734W is not programmed as a
Device Number in the panel.
CONNECT STATUS
DUPLICATE DEVICE
Duplicate Device: There is another device on the WiFi network with the same device number.
CONNECT STATUS
XMIT TIME xxx mS
Transmit Time XXX: The speed in milliseconds in which the last message was sent and received
between the 734W and the panel.
734W
PROGRAMMER
734W
INITIALIZATION
INITIALIZATION
COMMS? NO YES
Programming Menu
Press the CMD key to enter programming and display initialization options.
Initialization Options
These options can set the 734W module programming memory back to factory defaults 		
in preparation for programming. Press any select key to enter the initialization menu.
Initialization Communications
Select YES to initialize the communication options back to factory defaults. Select NO to
leave communication options unchanged.
INITIALIZATION
SURE?
YES NO
Initialize Confirm Option
INITIALIZATION
ACCESS?
NO YES
Initialization Access
INITIALIZATION
SURE?
YES NO
Initialize Confirm Option
734W
COMMUNICATION
734W Installation Guide
After selecting YES to clear the Communication settings, the 734W displays SURE? YES NO
for confirmation to clear the memory. This is a safeguard against accidentally erasing the
programming. No memory is cleared from the programming until you answer YES to the
SURE? option. Selecting NO leaves communication options unchanged.
Select YES to initialize the Access Options back to factory defaults. Select NO to return to
the INITIALIZATION menu.
After selecting YES to clear the Access Options, the 734W displays SURE? YES NO for 		
confirmation to clear the memory. This is a safeguard against accidentally erasing the 		
programming. No memory is cleared from the programming until you answer YES to the SURE?
option. Selecting NO leaves communication options unchanged.
Communication Menu
Press any select key to enter the Communication menu. Press the CMD key to advance to
the Access Options menu. Press the back arrow to display the 734W Initialization menu.
Digital Monitoring Products
734W DEVICE NO:
734W Device Number
734W
DHCP?
734W DHCP
NO
YES
Enter a device number from 2-16 for the 734W. The device number must also be 		
programmed as a device in the panel. Default is 7.
Select YES (fourth select key) to use dynamic IP address information for the 734W IP 		
Address, Subnet Mask, and Gateway Address. Select NO (third select key) to enter static
IP information.
734W IP ADDRESS:
192.168.0.201
734W IP Address
SUBNET MASK:
255.255.255.0
Subnet Mask
GATEWAY ADDRESS:
192.168.0.1
PANEL IP ADDR:
0.0.0.0
Enter the IP address of the 734W. Default is 192.168.0.201.
Enter the local subnet mask assigned to the 734W. Default is 255.255.255.0
Gateway Address
Enter the local gateway address of the 734W. Default is 192.168.0.1
Panel IP Address
Enter the IP address of the panel. Default is 0.0.0.0.
Note: This IP address must match the address programmed in the panel at the Local IP 		
Address prompt in Network Options. The DHCP programming in the panel must be set to NO.
PANEL IP PORT:
2002		
Panel IP Port
734W PASSPHRASE
734W Passphrase
734W
ACCESS OPTIONS
ACTIVATE ZONE 2
BYPASS? NO YES
ZONE 2 BYPASS
TIME:		 40
Enter the port number that the 734W uses to send communication to the panel. This must
be the same port that is programmed in 734W Listen Port in Network Options 			
programming of the panel.
Enter an 8 to 16-character alphanumeric Passphrase to encrypt communication with the
panel. The 734W Passphrase must match the 734W Passphrase entered in Network Options
programming of the panel. The Passphrase is blank by default.
Note: A passphrase is required for communication to occur with the panel.
Access Options
Press any select key to enter the Access Options menu. Press the CMD key to advance to the
Stop prompt. Press the back arrow to display the Communication menu.
Activate Zone 2 Bypass
Select YES to activate the Zone 2 Bypass operation. Selecting NO allows standard zone
operation on Zone. Default setting is NO. If the door being released by the 734W module is
protected (contact installed), you can provide a programmable bypass entry/exit timer by
connecting its contact wiring to the 734W module Zone 2. When the on-board Form C relay
activates and the user opens the door connected to Zone 2, the zone is delayed for the 		
number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter/exit during
an armed period.
If Zone 2 does not restore (door closed) within the programmed time, the piezo sounds every
other second during the last ten seconds. If Zone 2 restores prior to the end of the 		
programmed time, the piezo silences. If the zone does not restore before the programmed
time, the 734W ends the bypass and indicates the open or short zone condition to the panel.
Zone 2 Bypass Time
Enter the number of seconds to elapse before the Bypass Timer expires. Range is from 20
to 250 seconds. Press any top row select key to enter the number of seconds. If the door
remains open when the timer expires a zone open/short is sent to the panel for Zone 2.
The default is 40 seconds. Figure 10 shows how the Bypass option works.
5 Second
Strike
10 seconds before
the bypass time expires,
40
the device beeps if
Seconds the door is still open.
40-Second Zone 2 Bypass
entry/exit timer.
End of
timer.
A zone open/short is
indicated if the door
remains open.
Figure 10: Zone 2 Bypass Timeline using default time
734W Installation Guide
Digital Monitoring Products
RELOCK ON ZONE 2
CHANGE? NO YES
Relock on Zone 2 Change?
ACTIVATE ZONE 3
REX? NO
YES
Activate Zone 3 Request to Exit
ZN 3 REX STRIKE
TIME: 5
Zone 3 REX Strike Time
ACTIVATE ONBOARD
SPEAKER? NO YES
Activate Onboard Speaker
CARD OPTIONS:
DMP
CARD OPTIONS:
DMP CUSTOM ANY
Selecting YES turns the relay off when Zone 2 returns to normal during the bypass. Selecting
NO leaves the relay on when Zone 2 faults to an open or short condition during bypass.
Turning off the relay at Door Closed allows a long strike time to be automatically ended and
relocks the door. The default is NO.
Selecting YES activates the Zone 3 Request to Exit (REX) option.
Selecting NO allows standard zone operation on Zone 3. Default setting is NO.
You can connect a PIR (or other motion sensing device) or a mechanical switch to Zone 3
to provide REX capability to the system.
When Zone 3 shorts, the on-board Form C relay activates for the programmed number of
seconds (see Zone 3 REX Strike Time). During this time, the user can open the protected
door to start the programmed Zone 2 Bypass entry/exit timer. After the programmed 		
number of seconds, the relay restores the door to its locked state.
The 734W module provides a bypass-only option for REX on Zone 3. When Zone 3 OPENS
from a NORMAL state, only a bypass occurs: the on-board relay does not activate. This
bypass-only option uses two methods of REX. The first REX device provides the programmed
bypass entry/exit timer. The second REX, or manual device such as a door knob, unlocks
the door.
An example of the shunt-only configuration is a door to an office that is locked 24 hours
a day. Users pass a REX motion detector positioned by the door to begin the programmed
exit timer. Within the programmed number of seconds the user must then manually 		
activate a second device, such as a REX device or manual door knob, to unlock the door. If
the door is opened after the programmed number of seconds, an open condition is indicated
to the panel.
Enter the number of REX seconds to elapse. Range is from 5 to 250 seconds. Press any
select key to enter the number of seconds. The default is 5 seconds.
Select YES to enable the onboard speaker for local annunciation, such as alarm and trouble
annunciations. Select NO to turn the speaker off for all operations. This does not affect
remote annunciator open collector (RA) operation. The default is NO.
Card Options
Typically, an access card contains data bits for a site code, a user code, and start/stop/		
parity bits. The starting position location and code length must be determined and
programmed into the 734W Module. Select DMP to indicate the reader sends a 26-45 bit data
string. To select the DMP option, press the first Select key under DMP. Default is DMP.
Select CUSTOM if using a non-DMP card or user code length of 6 to 10 digits.
Select ANY to allow all card reads to activate the door strike relay. The door strike relay is
activated for the length of time programmed in ZN 3 REX TIME. No user code information is
sent to the panel.
Note: When set to DMP, the 734W converts 17 bits of the 26 to 45-bit data string into a
5-digit number.
01110101101101010001100111
First Bit
Received
Position = 0
Site Code
User Code
Last Bit
Position = 2
Position = 10
Received
Length = 8
Length = 16
Position = 25
In this example the Wiegand Code Length = 26 bits.
Figure 11: HID 26-bit Weigand Data Stream Bit Location
WIEGAND CODE
LENGTH: 26
SITE CODE
POSITION:
Custom Card Definitions
When using a custom product, enter the total number of bits to be received in Wiegand
code including parity bits.
Press any top row Select key to enter a number between 0-255 to equal the number of bits.
Default is 26 bits.
Site Code Position
734W Installation Guide
Enter the site code start position in the data string. Press any Select Key to enter a number
between 0-255. Default is 1. Press the COMMAND key to save the entry.
Digital Monitoring Products
SITE CODE
LENGTH: 8
Site Code Length
Enter the number of Site Code bits used. Press any Select Key to enter a number between
1-16. Default is 8. Press the COMMAND key to save the entry.
USER CODE
POSITION: 9
User Code Position
USER CODE
LENGTH: 16
User Code Length
REQUIRE SITE
CODE: NO
YES
Require Site Code
SITE CODE 1:
(1 - 65,535) 127
SITE CODE 2:
(1 - 65,535) SITE CODE 8:
(1 - 65,535) NO. OF USER CODE
DIGITS: 5
Site Code Display
Define the User Code start bit position. Press any Select Key to enter a number between
0-255. Default is 9. Press the COMMAND key to save the entry.
Define the total number of User Code bits used. Press any Select Key to enter a number
between 1-255. The default is 16.
Press the top row Select key under YES to use a site code and press the COMMAND key to
view the site code entry display. In addition to User Code verification, door access is only
granted when any one site code programmed at the SITE CODE ENTRY option matches the
site code received in the Wiegand string.
You can program up to eight five-digit site codes. Site code range is 1-65535.
SITE CODE 1 displays first. Any previously programmed site code displays. Default is 127.
To change the site code, press a select key, then enter the new code. Press the COMMAND
key to save and to display the next site code.
Site Codes 2-8 default to blank.
Number of User Code Digits
The 734W module recognizes user codes from one to ten digits in length. Press any top row
Select key to enter a user code digit length between 1-10 digits. This number must match the
user code number length being programmed in the panel. Default is 5.
All bits are read and converted into a decimal number string. The number string is left
padded with '0' if needed for long user code lengths. When selecting '4' the right digit is
dropped and the next four sent.
Example: # decoded			
1234567
			10 digits			0001234567
5 digits				34567
4 digits				3456
NO COMM WITH PNL
OFF SITE ANY ON
NO COMM WITH PNL
LAST
734W
STOP
No Communication with Panel
This option defines the relay action when communication with the panel has not occurred
for five seconds. Default is OFF. Press any top row Select key to change the default relay
action.
Choose the action required when the 734W cannot establish communication with the panel:
Press the first Select key to choose OFF (Relay Always Off) — The relay does not turn on
when any Wiegand string is received. OFF does not affect any REX operation. If 		
communication is lost during a door strike, relay remains on for the door strike duration,
but turns off at the end of the door strike timer.
Press the second Select key to choose SITE (Accept Site Code) — Door access is granted
when the Wiegand site code string received matches any site code programmed at SITE
CODE 1-8. For details refer back to the REQUIRE SITE CODE option.
Press the third Select key to choose ANY (Any Wiegand Read) — Door access is granted when
any Wiegand string is received.
Press the fourth Select key to choose ON (Relay Always On) — The relay is always on.
Press the COMMAND key to display the next action.
Press the first Select key to choose LAST (Keep Last State) — The relay remains in the same
state and does not change when communication is lost. If communication is lost during a
door strike, the relay remains on for the door strike duration, but then returns to it's last
state prior to doing the door strike.
Stop
Press any select key to start the stop routine. When programming in complete, the Version
displays and the keypad can now be removed.
FCC Information
Electronic Emission
This device complies with CFR47 Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
734W Installation Guide
Digital Monitoring Products
FCC Frequency Interference
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to CFR47 Part 15.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
residential environment, not withstanding use in commercial, business and industrial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC Radiation Exposure
To comply with FCC Radio Frequency exposure requirements in section 1.1307, a minimum separation distance of 20 cm. is
required between the antenna and all occupational persons, and a minimum separation distance of 20 cm. is required between
the antenna and all public persons.
Antenna Installation
WARNING: It is installer’s responsibility to ensure that when using the authorized antennas in the United States (or where FCC
rules apply); only those antennas certified with the product are used. The use of any antenna other than those certified with the
product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. The installer should configure the output power
level of antennas, according to country regulations and per antenna type. Professional installation is required of equipment with
connectors to ensure compliance with health and safety issues.
Industry Canada Information
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry
Canada to operate with the antenna provided with the maximum permissible gain and required antenna impedance. Antenna
types not included, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this
device.
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil
doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Alarm
Form C Relay
Zones
Dimensions
8.5 VDC to 28.5 VDC
100mA
+ 1.6mA per active zone
100mA
+ 10mA with Annunciator ON
+ 2mA per faulted zone
35mA at 12/24 VDC
5 VDC, 2mA max
4.5” W x 2.75” H x 1.75” D
Compatibility
XR100/XR500 Series panels
Accessories
Proximity Readers
PP-6005B
MP-5365
PR-5455
MX-5375
TL-5395
ProxPoint® Plus Proximity Reader
MiniProx™ Proximity Reader
ProxPro® II Proximity Reader
MaxiProx® Proximity Reader
ThinLine II® Proximity Reader
Proximity Credentials
1306P
1306PW
1326
1346
1351
1386
DMP Prox Patch
Prox Patch™
ProxCard II® Card
ProxKey II® Access Device
ProxPass®
ISOProx II® Card
Listings and Approvals
FCC Part 15 ID: CCKPC0110
Industry Canada ID: 5251A-PC0110
800 - 641 - 4282
INTRUSION
•
FIRE
•
ACCESS
•
NETWORKS
www.dmp.com
2500 North Partnership Boulevard
Made in the USA
S p r i n g fi e l d , M i s s o u r i 6 5 8 0 3 - 8 8 7 7
12055
Primary Power
Current Draw
Standby
LT-1213 © 2012 Digital Monitoring Products, Inc.
Specifications

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51
Create Date                     : 2012:02:14 08:55:45-06:00
Modify Date                     : 2012:02:14 08:55:52-06:00
Metadata Date                   : 2012:02:14 08:55:52-06:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5.2)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 11368 bytes, use -b option to extract), (Binary data 10467 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:f46d113d-71df-43bd-8f96-a2163233b474
Document ID                     : xmp.did:3866ABAECC51E1118297DAEC32D76623
Original Document ID            : adobe:docid:indd:59457fd3-a508-11dd-a532-958250ea8e87
Rendition Class                 : proof:pdf
Contributor Resources Document ID: uuid:0b0b70e2-4e68-4fac-8999-354d5573df31
Derived From Instance ID        : xmp.iid:A707442CCC51E1118297DAEC32D76623
Derived From Document ID        : xmp.did:85A0D6906943E111A4A2D98B67AFB0A5
Derived From Original Document ID: adobe:docid:indd:59457fd3-a508-11dd-a532-958250ea8e87
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:A6443E29FC41E11199A7FCF373CF6D5C, xmp.iid:A7443E29FC41E11199A7FCF373CF6D5C, xmp.iid:05A3EEC60942E11199A7FCF373CF6D5C, xmp.iid:F17A217A1042E111B0EBA8B3313218F8, xmp.iid:F27A217A1042E111B0EBA8B3313218F8, xmp.iid:005995241242E111B0EBA8B3313218F8, xmp.iid:308D4CB32A42E11199A7FCF373CF6D5C, xmp.iid:3E3686882F42E111B0EBA8B3313218F8, xmp.iid:4B60E0703342E111B0EBA8B3313218F8, xmp.iid:ABFC59413842E111B0EBA8B3313218F8, xmp.iid:6894DC5F3842E111B0EBA8B3313218F8, xmp.iid:F4C0BA763A42E111B0EBA8B3313218F8, xmp.iid:2FD85D9FB842E1119755B243F161E802, xmp.iid:B2379E9FB842E1119755B243F161E802, xmp.iid:9CEFE185C042E1119755B243F161E802, xmp.iid:8D0822F5C242E1119755B243F161E802, xmp.iid:1924D31FC342E1119755B243F161E802, xmp.iid:1A24D31FC342E1119755B243F161E802, xmp.iid:BCC12A82C542E1119755B243F161E802, xmp.iid:47C153B5E342E1119377B1C86A82E1D2, xmp.iid:25D90AB4E842E1119377B1C86A82E1D2, xmp.iid:8218AE906943E111A4A2D98B67AFB0A5, xmp.iid:85A0D6906943E111A4A2D98B67AFB0A5, xmp.iid:7934A8A97243E111A4A2D98B67AFB0A5, xmp.iid:03D82A177643E111BDF98482B3E801C7, xmp.iid:78FC25998743E111A4A2D98B67AFB0A5, xmp.iid:A26F2D958A43E111A4A2D98B67AFB0A5, xmp.iid:81B3DC3C8B43E111A4A2D98B67AFB0A5, xmp.iid:22CE73728C43E111A4A2D98B67AFB0A5, xmp.iid:6AFB673D8D43E111A4A2D98B67AFB0A5, xmp.iid:51FD1FB18E43E111A4A2D98B67AFB0A5, xmp.iid:B0496E8EB343E111A247BCF7296C5429, xmp.iid:DB583A5FB643E111A247BCF7296C5429, xmp.iid:08D61B57B743E111A247BCF7296C5429, xmp.iid:B279E94EC043E111A247BCF7296C5429, xmp.iid:9FE6C9EFC043E111A247BCF7296C5429, xmp.iid:1B3113AFC243E111A247BCF7296C5429, xmp.iid:01EBBC6CE845E111A78A802E69224B12, xmp.iid:6B29EC55E945E111A78A802E69224B12, xmp.iid:F933BA8DE945E111A78A802E69224B12, xmp.iid:4D2B11F8F845E111A78A802E69224B12, xmp.iid:57535C14F945E111A78A802E69224B12, xmp.iid:DEE39528FC45E111A78A802E69224B12, xmp.iid:57E8D42D0746E111A78A802E69224B12, xmp.iid:BC0C745E7547E111965B967E428F11CA, xmp.iid:83A2167D7747E111965B967E428F11CA, xmp.iid:9597FEDC7B47E111965B967E428F11CA, xmp.iid:385FE7A28C47E111965B967E428F11CA, xmp.iid:263239108E47E11196CEB6B3253F69CC, xmp.iid:5D31074B8E47E111965B967E428F11CA, xmp.iid:6AF1777D8E47E111965B967E428F11CA, xmp.iid:6BF1777D8E47E111965B967E428F11CA, xmp.iid:8888272E824BE111AB0595AB1687CD57, xmp.iid:5150F1F48F4BE111AB0595AB1687CD57, xmp.iid:DBA94AF01F4CE1118FE9FD06B89B3D0B, xmp.iid:A607442CCC51E1118297DAEC32D76623, xmp.iid:A707442CCC51E1118297DAEC32D76623, xmp.iid:3866ABAECC51E1118297DAEC32D76623, xmp.iid:77418780CF51E1118297DAEC32D76623, xmp.iid:F63D676ED351E1118297DAEC32D76623, xmp.iid:D11691076D52E111961CC7F59A765D93, xmp.iid:6499C2841A57E111AB10AED4C3B9979F, xmp.iid:D6962EED1B57E111AB10AED4C3B9979F
History When                    : 2012:01:18 11:45:07-06:00, 2012:01:18 11:45:07-06:00, 2012:01:18 13:22:35-06:00, 2012:01:18 14:10:33-06:00, 2012:01:18 14:10:33-06:00, 2012:01:18 14:22:28-06:00, 2012:01:18 17:18:16-06:00, 2012:01:18 17:52:51-06:00, 2012:01:18 18:20:50-06:00, 2012:01:18 18:55:18-06:00, 2012:01:18 18:56:09-06:00, 2012:01:18 19:11:06-06:00, 2012:01:19 10:14:11-06:00, 2012:01:19 10:14:11-06:00, 2012:01:19 11:10:44-06:00, 2012:01:19 11:28:10-06:00, 2012:01:19 11:29:21-06:00, 2012:01:19 11:42:13-06:00, 2012:01:19 11:46:25-06:00, 2012:01:19 15:22:36-06:00, 2012:01:19 15:58:21-06:00, 2012:01:20 07:20:47-06:00, 2012:01:20 07:20:48-06:00, 2012:01:20 08:25:55-06:00, 2012:01:20 08:50:27-06:00, 2012:01:20 10:55:46-06:00, 2012:01:20 11:17:08-06:00, 2012:01:20 11:21:49-06:00, 2012:01:20 11:30:29-06:00, 2012:01:20 11:36:09-06:00, 2012:01:20 11:46:33-06:00, 2012:01:20 16:10:26-06:00, 2012:01:20 16:30:35-06:00, 2012:01:20 16:37:31-06:00, 2012:01:20 17:41:43-06:00, 2012:01:20 17:46:13-06:00, 2012:01:20 17:58:43-06:00, 2012:01:23 11:33:55-06:00, 2012:01:23 11:40:26-06:00, 2012:01:23 11:42-06:00, 2012:01:23 13:32:21-06:00, 2012:01:23 13:33:08-06:00, 2012:01:23 13:55:11-06:00, 2012:01:23 15:14:04-06:00, 2012:01:25 10:55:21-06:00, 2012:01:25 11:10:32-06:00, 2012:01:25 11:41:51-06:00, 2012:01:25 13:41:55-06:00, 2012:01:25 13:52:09-06:00, 2012:01:25 13:53:46-06:00, 2012:01:25 13:55:11-06:00, 2012:01:25 13:57:42-06:00, 2012:01:30 14:37:09-06:00, 2012:01:30 16:15:46-06:00, 2012:01:31 09:26:25-06:00, 2012:02:07 14:41:55-06:00, 2012:02:07 14:45:34-06:00, 2012:02:07 14:45:34-06:00, 2012:02:07 15:05:45-06:00, 2012:02:07 15:33:53-06:00, 2012:02:08 09:53:23-06:00, 2012:02:14 08:45:20-06:00, 2012:02:14 08:55:25-06:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Doc Change Count                : 9866
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS5.5 (7.5.2)
EXIF Metadata provided by EXIF.tools