VENTED GAS FIREPLACE INSTALLATION AND OWNER’S OPERATION MANUAL 4" B-VENT DECORATIVE GAS FIREPLACES PFS ® US MODELS(V)CB36N(E) AND (V)CB36P(E) WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference. For more information, visit www.fmiproducts.com TABLE OF CONTENTS Safety................................................................... 2 Product Identification............................................ 4 Local Codes......................................................... 4 Product Features.................................................. 5 Pre-Installation Preparation.................................. 5 Installation Precautions........................................ 9 Venting Installation............................................... 9 Installing Optional Controls................................ 12 Fireplace Installation.......................................... 15 Operating Fireplace............................................ 20 Inspecting Burners............................................. 23 Cleaning and Maintenance................................. 24 Specifications..................................................... 25 Service Hints...................................................... 25 Technical Services.............................................. 25 Troubleshooting.................................................. 26 Replacement Parts............................................. 31 Accessories........................................................ 31 Parts................................................................... 32 Warranty...............................................Back Cover SAFETY WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer 2 State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! This fireplace complies with the National Safety Standards and is listed and tested by PFS Corporation to ANSI Z21.50 standard as vented gas fireplace. NOTICE: Decorative product not for use as a heating appliance. www.fmiproducts.com 117437-01F SAFETY Continued This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be installed by a qualified (certified or licensed) service person. If this unit is not properly installed by a qualified service person gas and/or carbon monoxide leakage (spillage) can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Any change to this fireplace or its controls can be dangerous. WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace. WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. 117437-01F Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on or around fireplace. Fireplace reaches high temperatures. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. Do not operate fireplace with glass door removed, cracked or broken. Carefully supervise young children when they are in the room with the fireplace. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. This product is intended only as a supplement to your central heating system and is not to be installed as a primary source of heat. You may use this product for emergency heating during a power outage. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors (propane/LP units only). www.fmiproducts.com 3 SAFETY Continued 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the fire department 4. Never install the fireplace • in a recreational vehicle • in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front • in high traffic areas 5. Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. 6. Turn fireplace off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. 7. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. PRODUCT IDENTIFICATION Top Louver Panel Glass Door Assembly 4" B-Vent Flue Collar Nailing Flange Log Set Junction Box (Electronic Ignition Only) Bottom Louver Panel 8. Have fireplace and venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 24. 9. Do not use this fireplace to cook food or burn paper or other objects. 10. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only gas type indicated on nameplate. 11. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electric Code, ANSI/NFPA 70. 12. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to arrange for replacement of the unit. 13. Do not operate fireplace if any log is broken or missing. 14. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. (45 kg) capacity (propane/LP units only). 15. Provide adequate clearances around air openings. LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 Control Valve Ember Tray Figure 1 - B-Vent Fireplace 4 www.fmiproducts.com 117437-01F PRODUCT FEATURES These are a few facts that can help you understand and enjoy your vented decorative fireplace: • The (V)CB36N(E) and (V)CB36P(E) series of vented decorative fireplaces may be recessed into an exterior chase, an interior flush wall enclosure or a framed-in corner installation. • Models (V)CB36N and (V)CB36P are equipped with a millivolt gas control system that does not require electricity to operate. A piezo ignitor is provided to light the pilot without using matches or lighters. • Models (V)CB36N(E) and (V)CB36P(E) are equipped with an electronic ignition system that requires 120 VAC to operate. An electrode ignitor automatically lights the pilot flame when the fireplace is turned on. • These fireplaces can accept any approved 4" B-Type venting system and must be terminated vertically through the roof using a listed type vent cap only. See venting instructions starting on page 8 for proper venting requirements. • These vented fireplaces require indoor air for combustion and must be installed in a room of sufficient size to provide adequate fresh air for safe and proper operation. The room intended for installation must be of sufficient size to meet the requirements for an unconfined space as defined in the National Fuel Gas Code, ANSI Z223.1/ NFPA 54. Air for Combustion and Ventilation. If sufficient air for combustion is not available a makeup air kit model AK4 may be required to provide outside air to this appliance. Check your local codes as to specific requirements for make up air. • This fireplace may be installed in any room of the house provided all local codes and these installation instructions are followed. PRE-INSTALLATION PREPARATION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient location for your FMI PRODUCTS, LLC B-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap. When deciding the location of your fireplace, follow these rules: • Do not connect this fireplace to a chimney flue servicing a separate solid fuel burning fireplace or appliance. • Do to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas, or near furniture or draperies. • Proper clearances must be maintained. • If your fireplace is to be installed directly on carpeting, vinyl, tile or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace (see Figure 3). • Only trim kits supplied by FMI PRODUCTS, LLC shall be used in the installation of this fireplace, see Accessories, page 31. • Do not install aftermarket vent dampers. Manual or automatic vent dampers are not approved for use with this appliance. Flush with a wall Through exterior wall enclosed in a chase Corner Installation Figure 2 - Common Fireplace Locations 25" (63.5 cm) 36" (91.4 cm) 36" (91.4 cm) Figure 3 - Fireplace Bottom Dimensions 117437-01F www.fmiproducts.com 5 PRE-INSTALLATION PREPARATION Continued • Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your fireplace, except when clearances are required from flue vent pipe, see Clearances. • If recessed into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member. • A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet standard requirements for hearth extensions. • If you plan on installing a television or entertainment center recessed above your fireplace, it is recommended that you maintain a minimum 18" (45.7 cm) above the top of louver opening. • When locating the termination cap, it is important to observe the minimum vent height and clearances required under code, see Venting Installation Instructions, page 9. • Do not recess termination cap into a wall or siding. • You may paint the termination cap with 450° F (232° C) heat resistant paint to coordinate with the exterior finish. PACKAGING AND REMOVAL The (V)CB36 vented decorative gas fireplaces are packaged with the following items: • one box containing a 4 piece log set located on the burner in the firebox. • one bag containing the owner’s manual with installation instructions, operator’s guide, and warranty information. • one bag of glowing ember material. • one bag of vermiculite hearth treatments. 1. Remove shrink wrap securing 2 carton trays to unit. 2. Lift top carton tray off and remove four corner posts. 3. Discard bottom tray once unit is moved into position. Note: To prevent damage to ceramic logs and glass panels you may want to remove them before positioning and framing the unit. To access firebox, see Louver Panels and Glass Door, page 17. 6 Carton Tray Corner Post Glass Panel Log Carton Figure 4 - Unpacking Fireplace CLEARANCES Minimum clearances to combustibles for fireplace: Back, Sides, Floor and Top 0" (0 mm) Perpendicular walls 10" (25.4 cm) Ceiling to Louver & Front 36" (91.4 cm) B-Vent Surfaces 1" (26 mm) (See venting instructions for specifics on vent clearances.) Mantel Clearances (See Mantel Clearances, page 8, for specific clearances to combustible mantels.) Combustible material with a maximum thickness of 5/8" (16 mm) may be flush with top and sides of front face of fireplace. FRAMING AND FINISHING Figure 5, page 7, shows typical framing of this fireplace. Figure 6, page 7, shows framing for corner installation. All minimum clearances must be met. For overall unit dimensions, framing allowances and vent collar locations, see Figure 7 on page 7. For available accessories for this fireplace, see Accessories, page 31. If you are using a separate combustible mantel piece, refer to Figures 8 and 9, page 8, for proper height and clearances. You can install a noncombustible mantel at any height above the fireplace opening. Note: Noncombustible mantels may discolor! www.fmiproducts.com 117437-01F PRE-INSTALLATION PREPARATION Continued 14 3/4" (37.5 cm) 21" (53.3 cm) To Center of Top Vent 28 5/8" (72.7 cm) ** 14 3/4" (37.5 cm) to Nailing Flanges 12 1/4" (31 cm) to Opening 56 3/4" (144 cm) 36" (91.4 cm) **These dimensions allow for 1" clearance at sides and back of fireplace. However, 0" clearance is also permitted at all sides when framed. 36 1/4" (92.1 cm) 14 3/4" (37.5 cm) Figure 6 - Framing Clearances for Corner Installation Figure 5 - Framing Clearances for Flush Wall Installation 14 3/4" (37.5 cm) to Nailing Flanges 8" (20.3 cm) Gas Supply Inlet 1 1/4" (3.2 cm) 5/8" (16 mm) 1 1/2" (3.8 cm) 36 1/4" (92.1 cm) Face Dimensions 37" (94 cm) to Nailing Flange 2 /2" (6.4 cm) 36" (91.4 cm) Face Dimensions 36 1/4" (92.1 cm) to Nailing Flange 2" (5.1 cm) 36 3/4" (93.4 cm) Wall Switch Wireway 4 1/2" (11.4 cm) Electrical Inlet 35 3/4" (90.8 cm) 38" (96.5 cm) Wall Switch Wireway 1 5 7/8" (15 cm) to Nailing Flange 6" (15.2 cm) 7 7/8" (20 cm) to Center of 4" B-Vent 11 1/8" (28.3 cm) Air Kit Location 15 3/8" (39 cm) Figure 7 - Unit Dimensions 117437-01F www.fmiproducts.com 7 PRE-INSTALLATION PREPARATION Continued MANTEL CLEARANCES Figure 8 shows projected mantel depths at various heights above top of louver opening. Figure 7, page 7, shows minimum allowable distances from various mantel components in relation to both sides of fireplace opening. 1 2 3 A 4 B C D WARNING: When finishing appliance do not overlap combustible materials onto the black front face. Brick, tile or other noncombustible materials may be applied to the face provided that any fireplace openings are not blocked and gaps in the material used and the face are sealed with a noncombustible caulking. Outer Surround Combustible Material May Be Used 1 1/2" (3.8 cm) 5 1/4" (13.3 cm) 3 1/2" (8.9 cm) Safe Zone 33° 6 E 7 F G 2 x 4 Header at 1" Min. Clearance 4" B-Vent Flue Pipe Top of Louver Opening Ref. 1 2 3 4 5 6 7 Mantel Depth Ref. 16" (40.6 cm) A 14" (35.6 cm) B 12" (30.5 cm) C 10" (25.4 cm) D 8" (20.3 cm) E 4" (10.2 cm) F 2" (5.1 cm) G Mantel from Top of Louver Opening 18" (45.7 cm) 16" (40.6 cm) 14" (35.6 cm) 12" (30.5 cm) 10" (25.4 cm) 8" (20.3 cm) 6" (15.2 cm) Figure 9 - Clearances for Combustible Mantels 1 3/4" (4.4 cm) To Fireplace Opening 5 Stud Wall 10" (25.4 cm) Perpendicular Side Wall Figure 8 - Side Clearances for Combustible Mantels 8 www.fmiproducts.com 117437-01F INSTALLATION PRECAUTIONS NOTICE: Failure to follow these instructions will void the warranty. • Wear gloves and safety glasses for protection • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on this product: • Installation of any damaged venting component • Unauthorized modification of the venting system (Do not cut or alter vent components) • Installation of any component part not manufactured or approved by FMI PRODUCTS, LLC • Installation other than as instructed by these instructions WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. WARNING: B-type vent pipe airspace clearance to combustibles is 1" on all sides. Where the vent pipe passes through a vertical wall a listed thimble approved for use with B-type vent must be used. VENTING INSTALLATION A 4" B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to install a standard B-type vent installation. Standing code requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building code authority for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code NFPA 54/ANSI Z223.1 for Category I systems using double wall B-1 vent pipe. This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid fuel burning appliance. This appliance may be vented through a manufactured chimney liner system if all are listed, inspected and approved by local codes and/or building authorities. The examples shown in Figure 10, page 10, are typical of most B-vent installations and code practices. 117437-01F WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Example 1: Shows the minimum allowable system height and lateral offset for a 60° or greater inclination. Code specifies that offsets at 60° or greater are considered horizontal and must follow the 75% rule for lateral to total vertical system height. Codes also allows only one offset in the total system when at 60° or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% rule applies. If the lateral length must exceed 75% then the system must be sized in accordance with the Category I venting tables. Example 2: Shows multiple offsets each at 45° of inclination. Multiple offsets are permitted if they do not exceed 45° of inclination. The total lengths of the two offsets are not required to meet the 75% rule. Example 3: Shows a single offset at 45° of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% allowable rule. www.fmiproducts.com 9 VENTING INSTALLATION Continued In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceiling joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained. Vent terminations must be located in accordance with height and proximity rules of NFPA No. 54. These rules apply to vents at 12" diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 foot distance from a vertical wall or obstruction (see Figure 11). If venting horizontally through a side wall becomes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall. Some codes areas allow the use of existing Btype vent systems if the system is at or above the recommended diameter of the flue. The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation. It is not recommended that this appliance be common vented with and existing gas burning appliance. However, if it becomes necessary to common vent the appliance. The venting system must be sized and configured in accordance with the common venting guides Appendix G of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1. Note: Before connecting this appliance to an existing vent system or a common venting system consult with your local architect planner, or building official. CHECKING FOR PROPER VENTING Listed Vent Cap Listed Vent Cap Maintain Listed Clearance Maintain Listed Clearance Support Each Lateral At Least Every 6 Feet 60 8' 12' Min. Listed Vent Cap Position Firestop 6' 45 Position Firestop Maintain Listed Clearance Maintain Listed Clearance Maintain Listed Clearance 12' Min. 45° Position Firestop 45 12' Min. Maintain Listed Clearance Maintain Listed Clearance EXAMPLE 1 EXAMPLE 2 Figure 10 - Typical B-Vent Configuration Roof Pitch Lowest Listed Discharge Vent Cap Opening 8 Ft. Min. Listed Gas Vent H (Min) Height From Roof x 12 Roof Pitch x/12 Listed Clearance 10' Flat to 6/12 6/12 to 7/12 Over 7/12 to 8/12 Over 8/12 to 9/12 Over 9/12 to 10/12 Over 10/12 to 11/12 Over 11/12 to 12/12 Over 12/12 to 14/12 Over 14/12 to 16/12 Over 16/12 to 18/12 Over 18/12 to 20/12 Over 20/12 to 21/12 EXAMPLE 3 H (Min.) 1.0 ft (0.3 m) 1.25 ft (0.38 m) 1.5 ft (0.46 m) 2.0 ft (0.61 m) 2.5 ft (0.76 m) 3.25 ft (0.99 m) 4.0 ft (1.22 m) 5.0 ft (1.52 m) 6.0 ft (1.83 m) 7.0 ft (2.13 m) 7.5 ft (2.27 m) 8.0 ft (2.44 m) Figure 11 - B-Vent Termination 10 www.fmiproducts.com 117437-01F VENTING INSTALLATION Continued After completing and checking electrical, gas and vent connections, follow lighting instructions and allow main burner to run for approximately 5 minutes. Hold a match or butane lighter flame, near opening between glass and fireplace face and play it along entire length of opening (Smoke may also be used). Proper venting will tend to draw flame or smoke into appliance. Improper venting, escaping or spillage of burned gas, is indicated when match flickers or goes out (see Figure 12). Smoke will also tend to disperse away from appliance. If appliance is not venting properly, shut it off and notify your installer or a qualified service agency to inspect venting system. ELECTRICAL SUPPLY CONNECTION Figure 12 - Checking for Spillage CAUTION: Disconnect the electrical power to the supply circuit before attempting to connect or service this appliance. Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only: 1. Remove 2 screws and outer cover with strain relief bushing on right side of cabinet (see Figure 13). 2. Remove inner retaining screw on junction box mounting tab. 3. Slide junction box up until screw mounting tab is lined up to notch in outer cabinet. 4. Swing junction box out and slip retaining flange out through slot in outer cabinet. 5. Remove 2 screws and outer cover on left side of outer cabinet. 6. Reinsert junction box retaining flange through slot now on left side and swing screw mounting tab back through notch as before. 7. Slide junction box down till mounting tab holes line up and replace inner retaining screw. 8. With junction box cover removed, pull end of 3-wire Romex supply line through universal strain relief bushing on cover. (see Figure 13). 9. Strip back outer Romex to about 4" and connect black, white and green wires accordingly using 3 wire nut connectors. 10. Tuck tailing wires into junction box and replace junction box cover using 2 remaining screws. 11. Tighten adjustment on universal strain bushing to secure Romex sheathing and complete supply connection. J-Box Cover with Strain Relilef J-Box Cover J-Box Cover with Strain Relief J-Box with A prewired junction box receptacle with strain Receptacle relief is provided on right side of cabinet for Romex hard wiring unit to a 15 Amp, 120 VAC, 60 Hz Cable grounded branch circuit. If installation demands Screw/Tab electrical supply be connected from the left, the Retainer entire receptacle box can be relocated to the left side by following these instructions: Figure 13 - Relocating Junction Box Receptacle and Electrical Supply Connection 117437-01F www.fmiproducts.com 11 VENTING INSTALLATION Continued WARNING: This appliance, when installed must be electrically grounded in accordance with local code or in the absence of local code, with the current National Electric Code, ANSI/ NFPA 70. HIGH ALTITUDE INSTALLATION When installing a non-high altitude fireplace at an elevation above 2,000 feet, you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1,000 feet above sea level. Check with your local gas company for proper orifice size identification. Consult your local gas company to help determine the proper orifice for your location. For assistance with any high altitude installation contact FMI PRODUCTS, LLC’s Customer Service Department at 1-866-328-4537. Your FMI PRODUCTS, LLC B-vent fireplace has been tested and approved in the USA for elevations from 0-2,000 feet. INSTALLING OPTIONAL CONTROLS INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2 1. Connect one terminal of 15 foot wire from wall switch to male connector on high limit harness. Connect remaining wire terminal to TH terminal on valve. Make sure that wire terminals are in positions on unit as pictured in Figure 14. If wires are not connected as shown switch will not work. 2. Route 15 foot wire through hole openings with bushings provided on either side of fireplace cabinet. 3. Connect one bare wire end to each of terminals of GWMS2 wall switch. 4. Install wall switch and cover in wall. IMPORTANT: Do not use any other wire than that provided with GWMS2 wall switch kit. Do not exceed 15 feet of distance from valve connection. Using wire of higher gauge or turns or exceeding minimum distance will increase resistance at control valve causing unreliable performance of fireplace controls. Wire Harness From Remote Receiver High Limit Switch or Wall Switch to Terminal Marked “TH” Male Connector to Remote Receiver or Wall Switch Figure 14 - Connecting Remote Receiver or Wall Switch to the Gas Control Valve 12 www.fmiproducts.com 117437-01F INSTALLING OPTIONAL CONTROLS Continued INSTALLING OPTIONAL WIRELESS REMOTE CONTROL - MODEL WRC (Electronic Ignition) Fireplace Receptacle Remote Control Receiver Installing and Activating the Remote Receiver 1. Open bottom louver and locate plug receptacle. Plug receptacle is located either on right or left side of cabinet. Ignition 2. The WRC model receiver does not require Module a battery. Receiver can be installed by Extension Cord Plug first plugging short extension cord into Figure 15 - Installing WRC Remote Receiver fireplace receptacle. Then plug receiver unit into extension cord. Finally plug igniBattery Cover tion module plug into receiver unit (see 12 Volt Battery Back of Handset Figure 15). 3. Activate remote handset battery by removing insulating tab on back of handset (see Figure 16). Battery is included pre installed 4. Once battery is activated unit is ready to Pull to use. Remove 5. Replace bottom louver panel. Insulation Tab Figure 16 - Installing Battery into Back of Handset 117437-01F www.fmiproducts.com 13 INSTALLING OPTIONAL CONTROLS Continued WIRING DIAGRAMS NOTICE: This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in case of a venting problem. Do not bypass the vent safety shutoff switch. If the appliance should shut down, have a qualified installer, service agency, or your gas supplier inspect the vent before operating. CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Millivolt Wiring Diagram Pilot Burner Thermocouple Replace factory wiring with 105° C equivalent or higher rating External wiring use only Class 2 thermostat wire 18 Ga. Red/White RED WHITE P I L OT FF Incoming Main Gas Supply NC TP TH/TP O Wall Switch/Remote Receiver Figure 17 - Millivolt Ignition Wiring Diagram ELECTRONIC IGNITION High Limit WIRING DIAGRAM Switch HIGH LIMIT SWITCH TH ON DO NOT CONNECT TO 120V Pilot Burner Ignitor NC Orange Gas Valve Red Red Black Black EV2 24 VAC Black Transformer Ignition Control Module MV PV TH P/MV GND TR EV1 White High Voltage Ground Blue Blue Green Ignition Module Figure 18 - Electronic Ignition Wiring Diagram 14 www.fmiproducts.com 120 VAC 117437-01F FIREPLACE INSTALLATION CHECK GAS TYPE Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install fireplace. See dealer where you purchased your fireplace for proper gas type fireplace or to purchase gas conversion kit (see Accessories, page 31). INSTALLING GAS PIPING TO FIREPLACE LOCATION WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply. Installation Items Needed Before installing fireplace, make sure you have the items listed below. • external regulator (supplied by installer) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * • sediment trap • tee joint • pipe wrench • approved flexible gas line with gas connector (if allowed by local codes) * An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the equipment shutoff valve from your retailer. For propane/LP connection only, installer must supply an external regulator. External regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with vent pointing down as shown in Figure 19. Pointing vent down protects it from freezing rain or sleet. 117437-01F CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur. Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 20). Propane/LP Supply Tank External Regulator with Vent Pointing Down Figure 19 - External Regulator with Vent Pointing Down (Propane/LP Only) Equipment Shutoff Valve with 1/8" NPT Tap* Approved Flexible Gas Line Natural - From Gas Meter (5.5" W.C. to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure) 3" Minimum Cap Pipe Tee Joint Nipple Sediment Trap/Drip Leg Figure 20 - Gas Connection * The equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer. www.fmiproducts.com 15 FIREPLACE INSTALLATION Continued IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off gas to appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 20, page 15. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly. CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • 3/4" and a 7/8" open end wrench or adjustable wrench • sealant (resistant to propane/LP gas, not provided) 1. Remove lower louver door panel by lifting up until disengaged. Swing forward and out of locating slots at bottom. 2. Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one access hole on each side of fireplace cabinet. 3. Attach flexible gas line from gas supply to the 1/2" flare fitting provided on control valve (see Figure 21). 4. Check all gas connections for leaks (see Checking Gas Connections). 16 To Gas Supply (Natural) Equipment Shutoff Valve To External Regulator (Propane/LP) Flexible Gas Line Do NOT Kink Control Valve Figure 21 - Connecting Flexible Gas Line to Millivolt Valve CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. www.fmiproducts.com 117437-01F FIREPLACE INSTALLATION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 22). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 23, for propane/LP or Figure 24, for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Equipment Shutoff Valve Open Closed Figure 22 - Equipment Shutoff Valve Propane/LP Supply Tank Equipment Shutoff Valve Gas Valve Figure 23 - Checking Gas Joints for Propane/LP Gas Fireplace Equipment Shutoff Valve Gas Meter Gas Valve PRESSURE TESTING FIREPLACE GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 22). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 23, for propane/LP or Figure 24, for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, page 20). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 20 or 21 depending on your model). LOUVER PANELS AND GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 31. CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers. Figure 24 - Checking Gas Joints for Natural Gas Fireplace 117437-01F www.fmiproducts.com 17 FIREPLACE INSTALLATION Continued Removing Louver Panels Remove top and bottom louver panels by simultaneously pulling both top end spring latches toward center of appliance until they are disengaged from locating holes (see Figure 25). Repeat for bottom spring latches and pull louvers outward. To install or replace items removed, simply reverse procedures above. Spring Clips 1. Lift Up Panel at Lower Rail Louver Panel Spring Latch Figure 25 - Removing Louver Panel Removing/Replacing Glass Door WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with glass door removed, cracked or broken. If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape remaining fragments onto frame. 1. Placing a screw driver or your finger tips into gap between lower glass panel rail and bottom face frame, lift glass door assembly until door pins clear locating holes in bottom face frame (see Figure 26). 2. Swing bottom glass panel assembly out until door pins on lower rail clear bottom face frame (see Figure 27). 3. Lower door down until upper door pins are free of locating holes in spring clips and place in a safe area. 4. Replace glass panel in reverse order by inserting top door pins into spring clips, lifting up at lower frame rail and locating bottom pins in holes on lower face frame. 18 Glass Panel Frame Rail Figure 26 - Removing/Replacing Glass Door Locating Hole 2. Swing Out Panel 3. Lower Panel Out Door Pin Glass Panel Frame Rail Figure 27 - Removing/Replacing Glass Door www.fmiproducts.com 117437-01F FIREPLACE INSTALLATION Continued INSTALLING LOGS AND GLOWING EMBERS A 4 piece ceramic log set comes packed inside the unit firebox. Removal of glass door is necessary to unpack and assemble logs and add hearth treatments. Follow steps under Removing/Replacing Glass Door, page 18 to access logs and burner. Assemble logs and add burner treatments as follows: 1. Position base log onto burner log mounts (see Figure 28). Top Left Log Top Right Log Rear Log 2. 3. 4. 5. Note: Cut out on bottom should fit over mounts and base log should be positioned against rear panel. Position holes on bottom of rear log over pins on base log (see Figure 28). Position top left log and top right log onto rear log and base log as shown in Figure 28. Break ember material into quarter sized pieces and place a single layer along the full length of ember tray to hide bottom edge of base log (see Figure 29). Replace glass door and louver panels (see Removing/Replacing Glass Door, page 18). WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. Burner Base Log Rear Log Stand Log Mounts Burner Pan Figure 28 - Installing Logs 117437-01F Ember Tray Ember Material Figure 29 - Applying Ember Material www.fmiproducts.com 19 OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Open lower louver panel. 3. Turn off all electric power to the fireplace. 4. Push in gas control knob slightly and turn clockwise to OFF (see Figure 30). 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near 20 LOT PI ON A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not light pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas go to the next step. 6. The pilot is located by the main burner and should not require accessing for lighting. 7. Turn gas control knob counterclockwise to PILOT. 8. Push in gas control knob all the way and hold. Immediately light the pilot by repeatedly pressing the piezo ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. • If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn gas control knob to OFF and call your service technician or gas supplier. 9. Turn on all electric power to fireplace. 10. Turn gas control knob counterclockwise to ON. 11. To leave pilot lit and shut off burners only: turn control knob clockwise to the PILOT position. Set wall switch or remote selector switch to OFF position to prevent draining battery. 12. Close lower louver panel. Regulator Cap OF F MANUAL IGNITION SYSTEM Gas Control Knob Piezo Ignitor Figure 30 - Control Valve Millivolt TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2. Set the wall switch to “OFF” position or the HRC selector switch (when equipped) to prevent draining the battery. 3. Turn off all electric power to the appliance if service is to be performed. 4. Push in gas control knob slightly and turn clockwise to OFF. 5. Close lower louver panel. 6. Close equipment shutoff valve (see Figure 22, page 17). www.fmiproducts.com 117437-01F OPERATING FIREPLACE Continued MANUAL LIGHTING PROCEDURE 1. Remove glass door (see Removing/Replacing Glass Door, page 18). 2. Follow steps 1 through 8 under Lighting Instructions, page 20). 3. Press gas control knob and light pilot with match. 4. Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 10 through 11 under Lighting Instructions, page 20). 5. Replace glass door (see Removing/Replacing Glass Door, page 18). ELECTRONIC IGNITION SYSTEM LIGHTING INSTRUCTIONS 1. STOP! Read the safety information, page 20. 2. Turn off all electrical power to the fireplace. 3. Turn wall switch to the OFF position. 4. Open lower louver panel. 5. Turn equipment shutoff valve clockwise to the OFF position (see Figure 31). Do not force. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 20. If you don’t smell gas go to the next step. 7. Turn equipment shutoff valve counterclockwise to the ON position. Do not force. 8. Close lower louver panel. 9. Turn on all electric power to fireplace. 10. Turn wall switch to the ON position. Figure 31 - Turning Equipment Shutoff Valve to the OFF Position 117437-01F 11. Visually locate pilot. Ignitor should begin to spark and main burner should ignite once flame appears at pilot. • If lighting appliance for the first time each season, it may take several attempts before supply gas can reach pilot and main burner. • If appliance will not stay lit after several attempts, follow instructions in To Turn Off Gas To Appliance, and call your service technician or gas supplier. NOTICE: During initial operation of a new fireplace, the burning of residues from the manufacturing process of the firebox and logs will produce a paper-burning smell and orange flames. Open a window for the first few hours of operation to adequately vent this smell. TO TURN OFF GAS TO APPLIANCE 1. Turn off wall switch. 2. Turn off all electric power to appliance if service is to be performed. 3. Open lower louver panel. 4. Turn equipment shutoff valve clockwise to OFF. Do not force. 5. Close lower louver panel. Ignitor Pilot Burner Sensor Rod Figure 32 - Pilot OPTIONAL WIRELESS REMOTE OPERATION Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 31). Follow installation instructions included with the remote control. 1. Turn equipment shutoff valve to ON position. You can now turn burner on and off with hand-held remote unit. www.fmiproducts.com 21 OPERATING FIREPLACE Continued IMPORTANT: Be sure to press the ON/ OFF buttons on hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press ON/OFF button to turn the burner on and off. OPTIONAL HAND-HELD REMOTE OPERATION Note: All remote control accessories must be purchased separately (see Accessories, page 31). Follow instructions included with the remote control. NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instructions, page 21. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 33). Note: Burner may light if hand-held remote was on when selector switch was last turned off. You can now turn burner on and off with hand-held remote control unit. IMPORTANT: Do not leave selector switch in the REMOTE or ON position when pilot is not lit. This will drain battery. Blower Control Knob (Optional Accessory) OT HI N O FF PIL ON OFF REMOTE Light fireplace as instructed in Lighting Instructions on page 21 . If using an optional remote with a wall switch, set remote selector switch to the ON position (see Figure 33). Wall switch may now be used to turn burner flame ON and OFF. To turn fireplace off, turn wall switch and/or remote selector switch to the OFF position and turn gas control knob back to PILOT. Pilot will remain lit. IMPORTANT: To turn pilot off, turn gas control knob on fireplace to the OFF position. ON LO Selector Switch in Remote Position WARNING: Do not connect the appliance gas controls to a 120 VAC power source. Damage or injury may occur. Variable Control Knob O OFF OPTIONAL GWMS2 ON/OFF WALL MOUNTED SWITCH Gas Control Knob in ON Position Figure 33 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation 22 www.fmiproducts.com 117437-01F INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary. The position and pattern of pilot flames in relation to sensing devices should be as shown in Figures 34 and 35 respectively. Pilot flame may need adjustment in order for thermocouple, thermopile and/or ignition system to sense pilot flame. If your pilot assembly does not meet these requirements: • turn fireplace off (see To Turn Off Gas to Appliance, page 20 or 21) • see sections under Troubleshooting, page 25 BURNER FLAME PATTERNS Burner flames will be steady, not lifting or floating. Flame patterns will differ from unit to unit and will vary depending on installation type and weather conditions. If vent configuration is installed incorrectly, flames will lift or “ghost”. This can be dangerous. Inspect flames after installation to ensure proper installation and performance. Figure 40 shows a typical flame pattern. If burner flame pattern differs from that described: • turn fireplace off (see To Turn Off Gas to Appliance, page 20 or 21) • see Troubleshooting, page 26 Thermopile 3/8" to 1/2" Pilot Burner 1/4" Figure 36 - Typical Flame Pattern AIR ADJUSTMENT SETTING Thermocouple Piezo Ignitor Figure 34 - Pilot Assembly (Millivolt Ignition System) Pilot Burner Sensor Rod Piezo Ignitor The main burner air shutter opening is factory set to the following: Natural Gas - 1/8", Propane/LP Gas - 3/4" Air shutter may require adjustment depending on altitude, venting condition, burner operation and general flame appearance. If flames are lifting or sooting shutter may require opening. If flames are too blue or improperly lighting shutter may require closing. See Figure 37 for proper air adjustment. IMPORTANT: Do not reduce air shutter opening any lower than designed minimum stop setting of 1/8". Burner Tube Air Shutter Figure 35 - Pilot Assembly Electronic Ignition System) Adjustment Screw 1/8" Minimum Air Opening Figure 37 - Adjusting Air Setting 117437-01F www.fmiproducts.com 23 CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passages of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate rial, pet hair, etc. GLASS DOOR WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken. WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot. Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non-abrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door, page 18, when removing glass door for cleaning. 24 WARNING: Only parts supplied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 31). This glass door panel is a complete unit. No substitute materials may be used. CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 18). Vacuum all glass pieces with a shop vac. CAUTION: Do not vacuum if pieces are hot. Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 31 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 18 for instructions for replacing glass door. WARNING: Do not block required air openings around glass or louver panels. Ventilated compartments should be inspected and vacuumed at least once a year to prevent blockage prior to operation. PILOT AND BURNERS • Remove ember material before cleaning burners and replace • Burner and controls should be cleaned with compressed air to remove dust, dirt or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint. www.fmiproducts.com 117437-01F CLEANING AND MAINTENANCE Continued LOGS • If you remove logs for cleaning, refer to Installing Logs and Glowing Embers, page 19, to properly replace logs. • Use a vacuum cleaner to remove any carbon buildup on logs. • Replace log(s) if broken. See Replacement Parts, page 31. • Replace ember material periodically as needed. See Replacement Parts, page 31. VENTING SYSTEM Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather corrosion (rust (V)CB36N spots or streaks and in extreme cases, holes). Have these items replaced immediately by a qualified service person. 2. Remove the vent cap and shine a flashlight into vent. Remove any foreign material. 3. Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather. 4. Inspect joints to verify that no pipe section or fitting has been distributed and loosened. Check mechanical supports such as wall straps for rigidity. SPECIFICATIONS • Maximum Input Rating: 18,000 Btu/hr • Gas Type: Natural • Orifice Size (Main Burner): #45 DMS (0.082") • Ignition: Millivolt • Manifold Pressure: 3.5" w.c. (0.87 kPa) • Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) (V)CB36P • Maximum Input Rating: 18,000 Btu/hr • Gas Type: Propane/LP • Orifice Size (Main Burner): #55 DMS (0.052") • Ignition: Millivolt • Manifold Pressure: 10" w.c. (2.5 kPa) • Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa) (V)CB36NE • Maximum Input Rating: 18,000 Btu/hr • Gas Type: Natural • Orifice Size (Main Burner): #45 DMS (0.082") • Ignition: Electronic • Manifold Pressure: 3.5" w.c. (0.87 kPa) • Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa) (V)CB36PE • Maximum Input Rating: 18,000 Btu/hr • Gas Type: Propane/LP • Orifice Size (Main Burner): #55 DMS (0.052") • Ignition: Electronic • Manifold Pressure: 10" w.c. (2.5 kPa) • Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa) ALL MODELS • Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm) • Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm) SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • for propane/LP units, propane/LP gas supply may be low You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier. 117437-01F TECHNICAL SERVICES You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your fireplace ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com. www.fmiproducts.com 25 TROUBLESHOOTING WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Manual Ignition System Only When ignitor button is pressed, there is no spark at ODS/pilot 1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet 1. Reconnect ignitor cable 3. Piezo ignitor nut is loose 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode positioned wrong 7. Ignitor electrode broken Manual Ignition System Only When ignitor button is pressed, there is spark at ODS/pilot but no ignition 1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed 5. Depleted gas supply (propane/LP only) 6. ODS/pilot is clogged 7. Gas regulator setting is not correct 26 www.fmiproducts.com 2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel. 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace pilot assembly 7. Replace pilot assembly 1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance, page 24) or replace ODS/pilot assembly 7. Replace gas regulator 117437-01F TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Manual Ignition System Only Pilot lights but flame goes out when control knob is released 1. Gas control knob not fully pressed in 2. Gas control knob not pressed in long enough 1. Press in gas control knob fully 2. After pilot lights, keep gas control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local natural or propane/LP gas company B) Clean pilot (see Cleaning and Maintenance, page 24) or replace pilot assembly 3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot to go out. This problem could be caused by one or more of the following: A) Low gas pressure B) Dirty or partially clogged pilot 5. Thermocouple connection loose at control valve. 6. Thermocouple damaged 7. Control valve damaged Burner does not light after pilot is lit or cycles during operation. 1. Burner orifice clogged 2. Inlet gas pressure is too low 3. Thermopile leads disconnected or improperly connected 4. Thermopile is defective 5. Improper venting or excessive blockage 5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace pilot assembly 7. Replace control valve 1. Clean burner (see Cleaning and Maintenance, page 24) or replace burner orifice 2. Contact local propane/LP or natural gas company 3. Reconnect leads 4. Replace thermopile 5. Have the vent system inspected, including the termination cap. Remove any restriction or obstruction Delayed ignition at burner 1. Manifold pressure too low 2. Burner porting or orifice clogged 1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance, page 24) or replace burner orifice Burner backfiring during combustion 1. Burner orifice is clogged or damaged 1. Clean burner (see Cleaning and Maintenance, page 24) or replace burner orifice 2. Replace damaged burner 3. Replace gas control 2. Damaged burner 3. Gas regulator defective Slight smoke or odor during initial operation 117437-01F 1. Residues from manufacturing processes and logs curing www.fmiproducts.com 1. Problem will stop after a few hours of operation 27 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heat produces a whistling noise when burner is lit 1. Turning gas control knob to HI position when burner is cold 2. Air in gas line 1. Turn gas control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by pro pane/LP or natural gas company 3. Clean burner (see Cleaning and Maintenance, page 24) or replace burner orifice 3. Dirty or partially clogged burner orifice Glass soots 1. Flame impingement on logs 2. Debris around burner air mixer 1. Adjust the log set so the flame does equipment shutoff valve 2. Inspect the opening at the base of the burner to see that it is not packed with any type of material Fireplace produces a clicking/ ticking noise just after burners are lit or shut off 1. Metal expanding while heating or contracting while cooling 1. This is normal. If noise is excessive, contact qualified service person Remote does not function 1. Battery is not installed or battery is power is low 1. Replace 9-volt batteries in receiver and remote control Fireplace shuts off in use. Burner backfiring during combustion 1. High or gusting winds 1. Fireplace has been tested for up to 40 mph winds. However, extreme conditions may occur. See Lighting Instructions, page 20 or 21 2. Check local propane/LP or natural gas company 3. Clean pilot (see Cleaning and Maintenance, page 24) 4. Locate and correct all vent conditions (see Checking for Proper Venting, page 10) 5. Clean burner tube and orifice, adjust air shutter (see Inspecting Burners, page 23) 6. Replace faulty components 7. Check for proper installation or remove debris or blockage 2. Low line pressure 3. Pilot is partially clogged 4. Improper or restricted venting 5. Clogged burner tube, blocked orifice or improper burner air adjustment 6. Bad thermopile or thermocouple 7. Vent cap improperly installed or blocked 28 www.fmiproducts.com 117437-01F TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Electronic Ignition Models Only Ignitor will not spark or pilot will not light 1. No gas supply, or shutoff valve is OFF 1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after repeated attempts appliance does not light, call for qualified service and repair 3. Remove debris and dirt, and inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pilot line 6. Replace control valve (Refer to Replacement Parts, page 31) 7. Check that main power is on and that wire connections are made correctly to the ignition model (see Wiring Diagrams, page 14). Check for 24 VAC at the secondary side of the transformer. If 24 VAC is present, and the module does not operate, have the module replaced otherwise have the transformer replaced 2. Air in gas line 3. Construction debris clogging pilot orifice 4. Low gas pressure 5. Kinked pilot line 6. Control valve is not opening 7. No power to unit or the ignition module Electronic Ignition Models Only Pilot will not stay lit 1. Loose wiring on ignitor wire to ignition module and/ or poor ground to ignition module 2. Pilot flame too low to sense Electronic Ignition Models Only Frequent outage of main burner and pilot after complete ignition sequence 117437-01F 1. Pilot flame may be too low to sense flame causing ignition module to shut down 2. Improper or restricted venting www.fmiproducts.com 1. Check wiring connection. Refer to wiring diagram (see Wiring Diagrams, page 14) and/or check ground wire to ignition module 2. Clean and adjust pilot burner and check gas supply and inlet pressure to unit. Note: Have a qualified technician replace pilot assembly if broken or corroded 1. Clean and adjust pilot flame for maximum flame across sensor rod 2. Locate and correct all vent conditions (see Checking for Proper Venting, page 10) 29 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. REMEDY OBSERVED PROBLEM POSSIBLE CAUSE Fireplace produces unwanted odors 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, page 16) Gas odor when control knob is in OFF position or during combustion 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, page 16) 2. Replace gas control valve Dark residue on logs or inside of fireplace 1. Improper log placement 2. Control valve defective 2. Air holes at burner inlet blocked 3. B u r n e r f l a m e h o l e s blocked 4. Improper venting or excessive blockage 5. Excessive amounts of embers and pan material 30 www.fmiproducts.com 1. Properly locate logs (see Installing Logs, Lava Rock and Glowing Embers, page 19) 2. Clean out air holes at burner inlets. Periodically repeat as needed 3. Remove blockage or replace burner 4. Have the vent system inspected, including the termination cap. Remove any restrictions or blockage 5. Clear excess embers from around rear main ports. Use a minimum one layer of smaller ember pieces to achieve best glowing effect over visible areas 117437-01F REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537. When calling FMI PRODUCTS, LLC have ready • your name and address • model and serial numbers of your fireplace • how fireplace was malfunctioning • type of gas (propane/LP or natural gas) • purchase date Usually, we will ask you to return the part to the factory. PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537 for referral information. A list of authorized dealers can be found by visiting www.fmiproducts.com. When calling FMI PRODUCTS, LLC, have ready • model number of your fireplace • the replacement ACCESSORIES NOTE: All accessories may not be available for all fireplace models. Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call FMI PRODUCTS, LLC at 1-866-328-4537, for information. You can also write to the address listed on the back of this manual PROPANE/NATURAL GAS CONVERSION KIT PCBM-36C - Propane/LP Gas Millivolt Models NCBM-36C - Natural Gas Millivolt Models PCBE-36C - Propane/LP Gas Electronic Models NCBE-36C - Natural Gas Electronic Models ON OFF RECEIVER AND HAND-HELD ON/ OFF REMOTE CONTROL MRC Allows the fireplace to be turned on and off conveniently with dual safety lock feature. REMOTE CONTROL KIT WRC SERIES Standard ON/OFF electronic remote control kit. ROLLED LOUVER TRIM KITS LTC36B - Brushed Brass LTC36P - Platinum 117437-01F WALL MOUNTED ON/OFF SWITCH GWMS2 Allows burner system to be turned on and off with a wall switch. www.fmiproducts.com 31 PARTS FIREPLACE ASSEMBLY FOR MODELS (V)CB36N, (V)CB36P, (V)CB36NE AND (V)CB36PE 5 6 13 26 10 7 27 11 18 9 16 15 19 26 8 4 23 26 22 3 2 24 21 17 12 20 25 14 1-4 1-3 1-1 1-2 32 www.fmiproducts.com 117437-01F PARTS 1 1-1 1-2 1-3 1-4 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 116108-01 116109-01 116110-01 111802-05 111802-04 117447-01 114889-01 106967-01 117461-01 117456-01 117455-01 114875-02 117450-01 117451-01 117452-01 117445-01 117458-01 117446-01 ** ** 110973-01 106543-01 26782 26290 24460 21171 20090 14418 14123 11408 11404 Log Set Burner Base Log Rear Log Right Top Log Left Top Log Burner Assembly Complete (See pages 30 and 32) Junction Box Duplex Plug Damper Assembly Vent Baffle Diverter Panel Heat Deflector Fireplace Surround Wire Harness Assembly Fireplace Top Fireplace Top Insulation Louver Assembly Hanger Bracket Glass Door Assembly Face Assembly Firebox Assembly (see pages 32 and 33 for details) Cover Junction Box High Limit Switch Screen Assembly Firebox Leg Gas Conduit Assembly Gas Knock-Out Cover Spring Clip Duplex Plug Receptacle Bushing Universal Strain Relief Bushing 0.5" Electric Cable Tie Down • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 25580 27253 117700-01 117701-01 Ember Bag Notice Label Wiring Diagram Label Wiring Diagram Label • • • • • • PARTS AVAILABLE - NOT SHOWN (V)C DESCRIPTION (V)C B36 N B36 P (V)C (V)C KEY NO. PART NO. B36 NE B36 PE This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • QTY. 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 2 1 2 2 2 2 2 1 1 3 1 1 1 1 1 ** Not a field replaceable part. 117437-01F www.fmiproducts.com 33 PARTS BURNER ASSEMBLY FOR MODELS (V)CB36N (V)CB36P, (V)CB36NE AND (V)CB36PE 3 7 4 8 9 5 Piezo Ignition Models Only 6 1 2 24 23 H HIG AG LT VO E 10 25 12 11 26 13 14 17 16 15 21 20 29 22 15 28 27 30 31 Electric Ignition Models Only 18 34 19 www.fmiproducts.com 117437-01F PARTS 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 117437-01F Remote Ignitor Bracket Ignitor Piezo Pilot Orifice #51 (Natural Gas) Pilot Orifice #30 (Propane/LP Gas) Pilot Orifice BL14LP (Propane/LP Gas) Pilot Orifice BL22N (Natural Gas) Burner Orifice #45 (Natural Gas) Burner Orifice #55 (Propane/LP Gas) Fitting Bulkhead w/ Nut Brass Washer, Flat 7/8" ID x 2" OD x 1/8" Thick Screw, #8 x 3/8" PPH F Zinc. Pilot Assembly (Natural Gas) Pilot Assembly (Propane/LP Gas) Pilot Assembly PSE (Natural Gas) Pilot Assembly PSE (Propane/LP Gas) Pilot Bracket Fitting Brass Elbow 3/8" MPT x 3/8" Comp. Tube Valve Bracket Tube 3/8" Dia. x 11" Aluminum Fitting Brass Straight 3/8" MPT x 3/8” Comp. Tube Gas Control Valve Millivolt (Natural Gas) Gas Control Valve Millivolt (Propane/LP Gas) Gas Control Valve Electric (Natural Gas) Gas Control Valve Electric (Propane/LP Gas) Screw, #10 x 1/2" HWH LGM Zinc Fitting 3/8" MPT x 1/2” Flare Screw, #10-32 x 1/4" PPH Zinc Screw, #8 x 1/4" PPH Air Shutter Ignition Module Bracket Nut, #8-32 Hex Zinc Cable, Tie 8.5” #10 Screw down Ignition Module Synetek Screw, #8-32 x 1” PPH Transformer, 24V Class 2 Screw, #8-32 x 1/2” PPH Ground Wire Harness Plug 24” Supply Connect Gas Valve Wire Harness (MV/PV) Gas Valve Wire Harness (MV) Gas Valve Wire Harness (PV) www.fmiproducts.com • • • • • • • • • • • • • • • • • • • (V)C DESCRIPTION (V)C (V)C B36 N B36 P 116317-01 102445-01 108085-01 108085-02 108867-01 108867-02 117702-01 26482 11214 11226 11102 117507-01 117507-02 108866-01 108866-02 24360 14399 26808 24389 14396 14512 14513 14569 14570 11105 14500 11107 11187 14299 116316-01 11201 11404 110286-01 11186 14129 11109 111059-03 108863-01 116719-01 116719-02 116719-03 (V)C KEY NO. 1 2 3 B36 NE B36 PE This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • QTY. 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 4 1 1 1 4 1 1 2 1 2 1 1 1 1 1 35 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag)______________________________ Serial No. (located on product or identification tag)___________________________ Date Purchased ___________________________ Keep receipt for warranty verification. FMI PRODUCTS, LLC LIMITED WARRANTIES New Products Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase. Factory Reconditioned Products Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions. Terms Common to All Warranties The following terms apply to all of the above warranties: Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented. This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product. This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner. All warranty will be voided if this product is used with a thermostat. Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s). This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product. FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact: 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www.fmiproducts.com 117437-01 Rev F 04/13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Create Date : 2013:04:11 07:24:17-07:00 Creator : Adobe InDesign CS5 (7.0.4) Modify Date : 2013:04:23 17:08:25-07:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2013:04:23 17:08:25-07:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 9331 bytes, use -b option to extract), (Binary data 10102 bytes, use -b option to extract) Instance ID : uuid:125f050a-5aac-40df-99db-4006219e3586 Document ID : adobe:docid:indd:dec8b248-32ec-11dc-9b45-bc4037bd5d42 Original Document ID : adobe:docid:indd:dec8b248-32ec-11dc-9b45-bc4037bd5d42 Rendition Class : proof:pdf Derived From Instance ID : 271901a1-2fca-11dc-b9af-f1f5d0a69a8b Derived From Document ID : adobe:docid:indd:271901a0-2fca-11dc-b9af-f1f5d0a69a8b History Action : saved, saved, saved History Instance ID : xmp.iid:68C3CD16B3A2E21189E5BBF92604AA74, xmp.iid:69C3CD16B3A2E21189E5BBF92604AA74, xmp.iid:42550076B3A2E21189E5BBF92604AA74 History When : 2013:04:11 07:21:24-07:00, 2013:04:11 07:21:24-07:00, 2013:04:11 07:24:03-07:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata Doc Change Count : 56 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 36EXIF Metadata provided by EXIF.tools