ALLFRAME

™

Multi-Modular I/O System

F6 Power Supply
Requirements & Options

Aviom’s AllFrame Multi-Modular I/O System offers unique flexibility in installation. In addition to supporting multiple I/O
complements and physical form factors, AllFrame devices can
be powered in a number of ways. This paper details the electrical requirements that must be met by any power supplies
used with AllFrame devices and provides critical guidelines for
ensuring proper performance.

Power Connector options
The F6 Modular I/O Frame features three power inlets: a two-pin Euroblock and a four-pin XLR for use with external
DC power supplies, as well as an RJ-45 A-Net® jack which can accept power injected on the Cat-5e cable.

Power Supply options
The F6 does not ship with a power supply. Third-party power supplies purchased for use with the F6 may be benchtop models, DIN rail supplies, or in-line bricks, as long as the minimum electrical specifications are met. In order to
prevent the F6’s case from sitting above ground due to voltage drop on the cable, a separate power supply must be
used to power each F6 in a system. Power supplies must be installed in accordance with the manufacturer’s instructions and adhering to all local electrical codes. Aviom has tested and approved the TDK-Lambda DPP120-48-1 and
Mean Well DR-120-48 DIN rail power supplies.
All three power sources may be used simultaneously with the F6 to create a redundant power sub-system.

Power over A-Net
Because the power requirements of the F6 exceed standard PoE and PoE+, standard PoE/PoE+ power injectors are
not suitable for use in AllFrame systems. Users who wish to power AllFrame units through the RJ45 jack must purchase the Aviom POA80 Power Over A-Net power supply assembly. No other power supplies have been approved
for powering AllFrame units in this manner.
While the POA80 provides certain protections against power irregularities that are common when cables are connected or disconnected, Aviom recommends against plugging or unplugging a network cable utilizing Power Over
A-Net while the POA80 is on.
Note that only the A-Net B port can accept PoA and no other A-Net ports should be connected to the powered
port of the POA80. The B port on the F6 may be used to supply power but not network data if the installation
layout so requires.

continued...

1157 Phoenixville Pike, Suite 201 • West Chester, PA 19380
Voice: +1 610.738.9005 • Fax: +1 610.738.9950 • www.Aviom.com

ALLFRAME

™

Multi-Modular I/O System

power via xlr or euroblock
DC Power supplies used with the F6 and connected to the Euroblock terminal connector or the 4-pin XLR jack must
meet the following requirements:
Power Supply Rating

Requires a UL60950-1 Certified/Listed ITE power supply having a SELV (Safety Extra
Low Voltage) rated output voltage between 30 and 60V DC

Voltage
(measured at the input of the F6 Modular I/O Frame)

30-60VDC, inclusive of tolerance

Maximum Current
(varies with input voltage)
(voltage at the input of the F6 Modular I/O Frame)

1.08A @ 60VDC
1.16A @ 56VDC
1.35A @ 48VDC
1.41A @ 44VDC
2.70A @ 24VDC
2.95A @ 22VDC

In order to meet emissions standards, an inline filter such as the Cosel NAC-10-472, may be required for installations that use external switching power supplies. For proper filtering, the power supply and filter should be
separated by twelve inches or more.

Cable Length & Voltage Drop
Maximum usable lengths for DC power cables used with the F6 and connected to the 4-pin XLR or Euroblock
terminal block connectors will vary based on the gauge of the wire and the voltage and power rating of the supply.
The cable will dissipate some of the power as heat, resulting in a voltage drop on the cable that increases with
cable length.
The table below presents power cable length as a function of wire gauge and supply voltage/power rating.

Maximum Cable Distance For Various Power Supplies
Wire Gauge

24V, +/-5% @ 100 Watts

48V, +/-5% @ 100 Watts

48V, +/-5% @ 120 Watts

12

75 feet, 23 meters

900 feet, 274 meters

1800 feet, 548.5 meters

14

48 feet, 15 meters

550 feet, 168 meters

1150 feet, 350.5 meters

16

30 feet, 9 meters

450 feet, 137 meters

725 feet, 221 meters

18

18 feet, 5.5 meters

300 feet, 91.5 meters

450 feet, 137 meters

Power Dissipation Of Cable
2.4 Watts

8 Watts

20 Watts

Connector Specifications
Connector Type

Pinout

2-pin terminal block

Pin 1: 30-60VDC (+)
Pin 2: Ground (-)

4-pin XLR

Pin 1: Ground
Pin 2/3: No Connect
Pin 4: 30-60VDC

Terminal Blocks
Phoenix Contact part number
17 54 44 9
Size: 5mm; 2 contacts per unit

Refer to the F6 User Guide for complete requirements and safety warnings.
All Aviom products are designed and manufactured in the USA.

Aviom, A‑Net, the A‑Net icon, Pro16, Pro64, Virtual Data Cables, m-control, and AllFrame are trademarks of Aviom, Inc. All other trademarks are the property of their
respective owners. ©2012 Aviom, Inc. All rights reserved. Information subject to change without notice. 	  rev. 1.3 072012



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Tagged PDF                      : Yes
Page Mode                       : UseThumbs
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Instance ID                     : uuid:46c59b8d-1550-4099-bd51-737069730e6c
Document ID                     : adobe:docid:indd:f24e6745-d26b-11e1-9b51-8b9544a5cd69
Rendition Class                 : proof:pdf
Derived From Instance ID        : aa6be4d4-3d58-11e1-85fc-e4466217f432
Derived From Document ID        : adobe:docid:indd:aa6be4d0-3d58-11e1-85fc-e4466217f432
Manifest Link Form              : ReferenceStream, DirectStream
Manifest Placed X Resolution    : 300.00, 72.00
Manifest Placed Y Resolution    : 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:0A262BFA7340E111B5EAEBB64D99BE68, uuid:abe72a69-18f9-4b85-94f5-4f9e33d363cf
Manifest Reference Document ID  : uuid:09A4965F5440E111B5EAEBB64D99BE68, uuid:772387BF70EFDA11B95D92B81AD2F696
Create Date                     : 2012:07:20 10:45:24-04:00
Modify Date                     : 2012:07:20 10:59:13-04:00
Metadata Date                   : 2012:07:20 10:59:13-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9690 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : Aviom AllFrame F6 Power Requirements
Creator                         : Aviom, Inc.
Subject                         : digital snake, digital multicore, digital snakes, audio network, networked audio, audio networking, pro64, a-net, audio over cat-5, audio over fiber, virtual data cable, gpio, rs-232, rs-422, word clock, audio distribution, midi, db25, remote control, allframe, modular IO, multi-modular, m-control, mcontrol, allframe, multi-modular, network manager, power supply, euroblock
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Keywords                        : digital snake, digital multicore, digital snakes, audio network, networked audio, audio networking, pro64, a-net, audio over cat-5, audio over fiber, virtual data cable, gpio, rs-232, rs-422, word clock, audio distribution, midi, db25, remote control, allframe, modular IO, multi-modular, m-control, mcontrol, allframe, multi-modular, network manager, power supply, euroblock
Page Count                      : 2
Page Layout                     : SinglePage
Author                          : Aviom, Inc.
EXIF Metadata provided by EXIF.tools

Navigation menu