1s Psu

User Manual: 1s-psu

Open the PDF directly: View PDF PDF.
Page Count: 1

Download1s-psu
Open PDF In BrowserView PDF
audio kits
power supply

Data Sheet

1S-psu

Date

March 2009

2 entrance relay
power supply module (9307.1)
•
•
•
•

Simply add this relay and any panel to any SRS
vandal resistant audio system using the 9307.1
power supply.
You must also add another entrance panel to the
system

12v AC / DC, 500 milli Amp
tone call generator
internal intercom impedance output
5 DIN with DIN rail included

audio door entry

relay module (9307.2)
• Adjustable lock release timer
• Lock release (change-over) relay
• negative trigger works with most door entry
systems
• 2 DIN with DIN rail included

DESCRIPTION

AN9102

(WITHOUT ADDITIONAL EQUIPMENT)

AC

•

•
USE

4+(n-2)

DC

fail open

fail secure

•

•

•

CW1308 BT

AK5343

wiring layout - 2 entrance panels

SYSTEM LOCKING OPTIONS

12V

CODE

two entrance relay

5

4+(n-1)

AN9102

SPEC TWISTED PAIR CABLE

5
DESCRIPTION

4+n

CODE

power supply unit
lock timer relay

9307.1
9307.2

9307
AK5343

9307.2 x 2

2

7+n

7+n

AC or DC

2
AC or DC

9307.2 timer for the lock release is required for each entrance
unless a keypad is fitted in the panel

alternative power supply
lockable power supply

time clock

• lockable box
• 12V AC & DC (1A)
• accepts telephone connection boards
• timed lock release
relay
• expandable BUSS
• battery charger circuit
DESCRIPTION

CODE

boxed power supply

5141

• clips onto 5141 chassis
• 16 adjustable time patterns, 7 day
• 12V AC/DC operation
• Single pole relay
• 1 Amp contacts
DESCRIPTION

CODE

time clock module

5200M

telephone connection boards
with telephone connections

Individual telephone connections
This makes for more reliable installation. Faulty
wiring on a telephone will only effect that phone
and not the whole system
You have a choice of connection systems. Using
an isolated connection system means that tenants cannot listen in on conversations and that
faulty or damaged telephones (or the wiring to
them) will not effect the operation of the rest of
the system.

timed lock release output

each telephone connection is
unpluggable to ease maintenance. This also allows vandalised telephones to be
temporarily disconnected.

as 5141 with 8 way
telephone board (5108)
fitted. Alternative with
16 phone connections
is 514116.

DESCRIPTION

CODE

power supply - 8 phone connections
power supply - 16 phone connections

514108
514116

DESCRIPTION

CODE

connection board for 8 telephones
connection board for 16 telephones

5108
5116

You will rarely find a door entry system with
timed lock release, but the SRS system does.

12v dc & 12v ac supply
You will not need to add additional power supplies to control your locking. Also, if the mains
power fails the door entry system will continue to
function (even ac lock releases)

with isolated connections
as 5141 with 5115 isolated line telephone
board fitted. This
means that each telephone cable is ISOLATED from the system.

Unpluggable connections throughout
This makes wiring much faster and easier to
check. In addition it is less likely that wiring
errors will be made, since all connections can be
seen in the power supply.

Up to 8 telephones to be
individually connected with
full isolation. That means
that damaged or shorted
phone connection will not
effect the system operation.

DESCRIPTION

CODE

DESCRIPTION

CODE

power supply - 8 isolated connections

514115

8 way isolated connection board

5115

Door Entry Direct Ltd

t : 0208 621 6210

Unit 1, AMC Business park

f : 0208 621 6211

12 Cumberland Avenue

e : sales@doorentrydirect.com

Park Royal, London

w: www.doorentrydirect.com

NW10 7QL

isolated connection board



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2009:08:06 10:32:39
Producer                        : Acrobat Distiller 4.05 for Macintosh
Modify Date                     : 2009:08:06 10:32:43+01:00
Page Count                      : 1
EXIF Metadata provided by EXIF.tools

Navigation menu