38AD028 38ARZ ARD
User Manual: 38AD028
Open the PDF directly: View PDF .
Page Count: 52
Download | ![]() |
Open PDF In Browser | View PDF |
38ARZ/ARD Commercial Air-Cooled Split Sizes 007 - 028 With 40RM007-028 5-24 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier’s 40RM indoor-air handlers for a wide selection of dependable commercial cooling solutions. Carrier’s air-cooled split systems: • provide a logical solution for commercial needs • have a rugged, dependable construction Features/Benefits These dependable split systems match Carrier’s indoor-air handlers and directexpansion coils with outdoor condensing units for a wide selection of commercial cooling solutions. Up to 11.0 EER The high efficiency split commercial split system combining the ARZ/ARD outdoor condensing unit with 0RM air handling unit can save 0-% of energy consumption. Constructed for long life The ARZ (single circuit, scroll compressor) and ARD (dual circuit, scroll compressor) models are designed and built to last. The copper tube-aluminum fin outdoor coil construction provides years of trouble-free operation. Where conditions require, a range of Enviro-Shield™ coil protection options are available. Cabinets are constructed of prepainted galvanized steel, delivering unparalleled protection from the environment. Inside and outside surfaces are protected to ensure long life, good looks, and reliable operation. Safety controls are used for enhanced system protection and reliability. 38AR-03 PD 50Hz CKAC 2010 Efficient operation The pitched, non-corroding drain pan can be adjusted for a right-hand or left-hand connection to suit many applications and provide positive drainage and prevent standing condensate. Building owners will appreciate the high unit EERs (Energy Efficiency Ratios) offered by the AR units. These units provide greater efficiency than similar units in the marketplace, which translates into yearround operating savings. Economy — The 0RM Series packaged air handlers have low initial costs, and provide reduced installation expense and energy-efficient performance. Quick installation is ensured by the multipoise design. Units can be installed in either the horizontal or vertical configuration without modifications. Fan motors and contactors are prewired and thermostatic expansion valves (TXVs) are factory-installed on all 0RM models. High efficiency, precision-balanced fans minimize air turbulence, surging, and unbalanced operation, cutting operation expenses. Controls for performance dependability The AR condensing units offer the building owner operating controls and components designed for performance dependability. The highly efficient compressors are engineered for long life and durability. The compressors include overload protection and vibration isolation for quiet operation. The high pressure switch protects the entire refrigeration system from abnormally high operating pressures. A low pressure switch protects the system from loss of charge. The ARD0-08 units feature compressors and refrigerant circuits that provide continuous air conditioning and design flexibility. All units include a crankcase heater to eliminate liquid slugging at start-up. The latest safety standards for AR units are UL, compliant. Rugged dependability — The 0RM series units are made to last. The die-formed galvanized steel panels ensure structural integrity under all operating conditions. Galvanized steel fan housings are securely mounted to a galvanized steel fan deck. Rugged pillow-block bearings (0RM0-0) are securely fastened to the solid steel fan shaft with split collets and clamp locking devices. Smaller unit sizes have spider-type bearings. Innovative Carrier 40RM packaged air handlers are custom matched to 38AR condensing units Coil flexibility — Model 0RM directexpansion coils have galvanized steel casings; inlet and outlet connections are on the same end. The coils are designed for use with R- refrigerant and have /-in. diameter copper tubes mechanically bonded to aluminum sine-wave fins. The coils include matched, factoryinstalled thermostatic expansion valves (TXVs) with matching distributor nozzles. The 0RM Series has excellent fan performance, efficient direct-expansion (DX) coils, a unique combination of indoor-air quality options, and is easy to install. Its versatility and state-of-the art features help to ensure economical performance of the split system both now and in the future. Indoor-air quality (IAQ) features — The unique combination of IAQ features in the 0RM Series air handlers help to ensure that only clean, fresh, conditioned air is delivered to the occupied space. Direct-expansion (DX) cooling coils prevent the buildup of humidity in the room, even during part-load conditions. Unit sizes of 0 tons and larger feature dual-circuit coils for improved temperature control. Standard -in. aluminum washable filters remove dust and airborne particles from the occupied space for cleaner air. Easier installation and service — The multipoise design and component layout ensures quick unit installation and operation. Units can be converted from horizontal to vertical operation by simply repositioning the unit. Drain pan connections are duplicated on both sides of the unit. The filters, motor, drive, TXVs, and coil connections are all easily accessed by removing side panels. Model number nomenclature 38AR Z 007 -- - 9 Type 38AR–Commercial AirCooled Condenser 0 1 S S - High Ambient Packaging 1 - Standard Z-Single Circuit D- Dual Circuit Design Series 0 - Original Design Nominal Capacity in-Tons 007 - 5.0 Tons 008 - 7 0 . Tons 012 - 8.7 Tons 014 - 10.8 Tons 016 - 14 Tons 024 - 18.1 Tons 028 - 24 Tons Voltage 9 – 400–3–50 Fin Type -- - Standard Bare Fins C- Cu/Cu Coil P- Pre-Coated Blue Fins -- - Not Used Table of Contents Page. 38ARZ/ARD Features/Benefits………………………………………………………………………………………. ModelNumber Nomenclature………………………………………………………………………….. Physical Data……………………………………………………………………………………………. ARI Capacity ratings 50Hz ……………………………………………………………………………. Options and accessories ………………………………………………………………………………. Electrical Data…………………………………………………………………………………………… Base Unit Dimensions………………………………………………………………………………….. Performance data ……………………………………………………………………………………… Application Data………………………………………………………………………………………… Typical Wiring Schematic………………………………………………………………………………. 1 3 4 6 7 7 8-10 11-20 21 22-26 Model number nomenclature………………………………………………………………………….. Physical Data……………………………………………………………………………………………. Options and accessories ………………………………………………………………………………. Base Unit Dimensions………………………………………………………………………………….. Fan Performance Data ……………………………………………………………………………….. Electrical Data…………………………………………………………………………………………… Typical piping and wiring ……………………………………………………………………………… Application Data………………………………………………………………………………………… 27 28, 29 30-32 33-40 41-47 48-50 51-54 54-58 Guide Specifications —38ARZ007-012………………………………………..…………………… Guide specifications— 38ARD014-028 ……………………………………………………………. Guide specifications —40RM………………………………………………………………………… 59,60 61,62 63,64 40RM Guide Specifications Physical Data – English UNIT 38AR NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Aluminium Coils (Standard) Cooper Coils (Optional) COMPRESSOR Qty Oil Charge (oz) REFRIGERANT TYPE * Operating Charge, Typical (lb) ** Shipping Charge (lb) FINISH CONDENSER FAN Qty…RPM Diameter Nominal Air Flow (Total CFM) Motor HP-Shaft CONDENSER COIL (Qty) Face Area (sq ft Total)) Rows…Fins/in. Storage Capacity (lb)*** CONTROLS Pressurerestart Settings (psig) High Cutout Cut-in Low Cutout Cut-in DISCHARGE GAS THERMOSTAT (0F) Cutout Cut-in PRESSURE RELIEF Location Tempreature PIPING CONNECTION Qty…Suction Qty…Liquid Hot Gas Stub UNIT 38AR SHIPPING DIMENSIONS (in) (W X H X D) 007 5.0 ARZ 008 7. 0 012 9.3 014 10. 8 ARD 016 14 024 18 .1 028 24 300 352 383 484 430 531 676 822 740 886 764 904 1279 1532 88 90 110 60(ea) 85(ea) 110(ea) 111(ea) 12 20 2.0 22 2…700 22 in 5000 2x1/8 Scroll R22 Gray Propeller Type 2…920 5800 2x1/4 29.2 1…17 17.3 11.5/circuit 2 2…17 34.2 428 ± 10 320 ± 20 27 ± 3 44 ± 5 270 ± 9 190 ± 13 --- Suction Line 200 1…1 1/8 1… 3/8 007 1…1 1/8 1… 3/8 ARZ 008 012 (59.2X45.5X39) *Unit is factory-supplied with holding charge only. **Typical operating charge with 25 ft of interconnecting piping. ***Storage capacity of condenser coil with coil 80% full of liquid R-22 at 95 F. 1…1 3/8 1… 1/2 014 016 024 (72.6X44.25X41.7) 3.1 14/circuit 17.97/circuit 2…900 26 in 9210 2x1/2 2…900 30 in 13000 2x1 29.2 3…15 48 50.4 3…16 - 428 ± 10 320 ± 20 27 ± 4 44 ± 7 428 ± 10 320 ± 20 27 ± 4 44 ± 7 --- --- Liquid Line 200 Liquid Line 200 2…1 3/8 2… 1/2 3/8 2…1 3/8 2… 5/8 - ARD 028 (96.5X49.6 X54.3) Capacity ratings 50 Hz CONDENSINGUNIT AIRHANDLER/INDOOR COIL 40RM007 40RM008 40RM007 40RM008 40RM012 40RM008 40RM012 40RM014 40RM014 40RM016 40RM024 40RM028 38ARZ007 38ARZ008 38ARZ012 38ARD014 38ARD016 38ARD024 38ARD028 CONDENSINGUNIT ONLYGROSSCAPACITY kW** Btuh SYSTEMGROSSCAPACITY kW* 18.4 19.0 23.3 24.0 25.4 30.1 31.9 33.4 Btuh 62,200 64,300 78,700 81,400 86,100 102,000 108,000 113,000 40.4 18.0 60,300 25.0 83,900 33.2 112,000 138,000 41.6 142,000 56.3 192,000 57.8 197,200 63.0 215,000 64.6 218,000 81.1 276,600 84.0 286,700 LEGEND db — Dry Bulb wb — Wet Bulb SST — Saturated Suction Temperature *System gross capacities are rated according to indoor unit airflow, 35 C air temperature entering condenser, and 20 C wb air temperature entering evaporator. †System gross capacities are rated according to indoor unit airflow, 95 F air temperature entering condenser, and 67 F wb air temperature entering evaporator. **Condensing unit gross capacity based on 36 C air temperature entering condenser and 8 C SST. ††Condensing unit gross capacity based on 95 F air temperature entering condenser and 45 F SST. UNIT 38AR Z007 Z008 Z012 D014 D016 D024 D028 SOUND RATING dB(A) 80.0 84.0 85.0 86.9 87.5 88.0 94.8 SOUND LEVELS, dB — 38AR UNITS OCTAVEBANDS 63 125 250 500 1000 2000 4000 8000 71.5 84.1 88.7 76.8 84.5 85.4 90.9 90.9 90.9 91.4 75.3 80.4 81.7 86.1 86.1 86.1 88.1 74.0 78.6 80.9 83.1 83.4 83.8 85.8 73.9 77.2 82.1 84.0 84.5 84.5 86.4 74.1 76.9 76.2 73.5 76.6 79.2 81.5 73.5 78.8 73.6 71.7 73.2 74.3 75.2 64.0 72.5 67.1 66.7 63.5 65.5 67.4 NOTES: 1. 38ARZ unit is in accordance with ARI 270-95 Sound Rating of Unitary Equipment. 2. Estimated sound power levels, dB re 1 Picowatt. 38ARD014-024 and 38AKS data is based upon a limited amount of actual testing with the estimated sound power data being generated from this data in accordance with ARI Standard 370 for large outdoor refrigerating and air-conditioning equipment. Since this data is estimated, the sound power levels should not be guaranteed or certified as being the actual sound power levels. 3. The acoustic center of the unit is located at the geometric center of the unit. ESTIMATED SOUND POWER LEVELS (Lw) — 40RM007-028 UNIT CFM dB(A) 40RM007 40RM008 40RM012 40RM014 40RM016 40RM024 40RM028 2400 3000 4000 5000 6000 8000 10000 86.3 88.3 91.6 91.1 92.7 96.4 96.2 63 93.2 95.3 98.6 97.3 98.9 102.6 102.5 125 89.2 91.3 94.6 93.3 94.9 98.6 98.5 OCTAVEBANDCENTERFREQUENCY 250 500 1000 85.2 84.2 80.2 87.3 86.3 82.3 90.6 89.6 85.6 89.3 90.3 84.3 90.9 91.9 85.9 94.6 95.6 89.6 94.5 95.5 89.5 2000 78.2 80.3 83.6 82.3 83.9 87.6 87.5 4000 74.2 76.3 79.6 78.3 79.9 83.6 83.5 Options and accessories 38AR, options Enviro-Shield™ condenser options offer pre-coated coils that provide protection in mild coastal environments. Several options are available to match coil protection to site conditions for optimum durability. See table below. Consult your Carrier representative for further information. Non-fused disconnect switch to remove power locally at the condensing unit. This switch also includes a power lockout capability to protect the service person. This lockout switch saves the service person time and effort because there is no need to access a distant disconnect switch while servicing the unit. Carrier’s line of thermostats provide both programmable and non-programmable capability with the new Debonair® line of commercial programmable thermostats. The Commercial Electronic thermostats provide -day programmable capability for economical applications. PremierLink™ Controller is a field retrofit split system control compatible with the Carrier Comfort Network (CCN) and other building automation systems (BAS). This control is designed to allow users the access and ability to change factory-defined settings thus expanding the function of the standard unit. CONDENSER COIL OPTIONS COPPERͲTUBECOILS WITHENVIROͲSHIELDOPTION AlFins(StandardCoils) CuFins ENVIRONMENT MildCoastal Standard X ModerateCoastal X X AlFins,PreͲCoated LEGEND Al — Aluminum Cu — Copper Electrical data VOLTAGE RANGE* COMPRESSOR 1 COMPRESSOR 2 UNIT SIZE 38AR NOMINAL VOLTAGE V-Ph-Hz MIN MAX RLA LRA RLA LRA Z007 Z008 Z012 D014 D016 D024 D028 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 360 360 360 360 360 360 360 440 440 440 440 440 440 440 9.6 13.5 20.7 9.6 13.5 20.7 22.9 82 95 130 82 95 130 145 ---9.6 13.5 20.7 22.9 ---82 95 130 145 LEGEND FLA — Full Load Amps LRA — Locked Rotor Amps MCA — Minimum Circuit Amps per NEC, Section 430-24 MOCP — Maximum Overcurrent Protection (amps) RLA — Rated Load Amps (compressor) FAN MOTORS (Qty 2) FLA LRA (ea) (ea) 0.5 0.9 0.8 1.6 0.8 1.6 1.7 -1.7 -1.7 7.5 3.0 -- POWER SUPPLY MCA MOCP 12.4 17.9 26.9 27.8 38.0 56.0 63.3 20 30 45 30 45 70 80 *Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above the listed limits. NOTES: 1. The MCA and MOCP values are calculated in accordance with theNational Electrical Code (NEC), Article 440. 2. Motor RLA and LRA values are established in accordance with Underwriters’ Laboratories (UL), Standard 1995. Base Unit Dimensions – 38ARZ 007 – 012 38ARZ Size 007 008 012 Approximate Shipping Weight With Standard Al/Cu Coil With Optional Cu/Cu Coil KG LB KG LB 154 339 178 392 192 422 238 524 213 467 259 570 Approx. Shipping Dimensions (AxBxC) mm inch (1504X1157X992) (59.2X45.5X39) Base Unit Dimensions – 38ARD 014 – 024 38ARD Size 014 016 024 Approximate Shipping Weight With Standard Al/Cu Coil With Optional Cu/Cu Coil KG LB KG LB 357 785 423 931 386 849 452 994 397 873 461 1014 Approx. Shipping Dimensions (AxBxC) mm inch (1844X1124X1058) (72.6X44.25X41.7) Base Unit Dimensions – 38ARD 028 10 38ARZ007 SST (F) 25 30 35 40 45 50 TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT 38ARZ008 SST (F) 25 30 35 40 45 50 TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT 38ARZ012 SST (F) 25 30 35 40 45 50 TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT CONDENSING UNIT RATINGS — ENGLISH 44.80 3.50 99.8 49.40 3.56 101.0 54.30 3.63 102.0 59.50 3.71 104.0 65.00 3.81 106.0 70.70 3.91 108.0 28 30 35 40 45 50 2 SDT 43.60 3.72 105.0 48.20 3.78 106.0 52.90 3.85 107.0 58.00 3.93 109.0 63.40 4.02 110.0 69.10 4.12 112.0 41.20 4.15 115.0 45.60 4.20 116.0 50.30 4.28 117.0 55.10 4.36 118.0 60.30 4.45 120.0 65.80 4.56 122.0 40.00 4.39 120.0 44.30 4.45 121.0 48.90 4.52 122.0 53.70 4.60 123.0 58.70 4.70 125.0 64.10 4.80 127.0 38.80 4.63 124.0 43.00 4.69 125.0 47.50 4.77 127.0 52.20 4.85 128.0 57.10 4.94 130.0 62.40 5.05 131.0 36.30 5.12 134.0 40.40 5.18 135.0 44.70 5.25 136.0 49.20 5.34 138.0 54.00 5.44 139.0 59.00 5.54 141.0 61.30 4.79 98.5 68.30 4.81 98.8 75.50 4.88 99.9 83.00 4.97 101.0 90.90 5.06 103.0 99.20 5.17 105.0 59.40 5.07 103.0 66.40 5.09 104.0 73.50 5.15 105.0 80.80 5.24 106.0 88.60 5.34 108.0 96.80 5.45 110.0 55.50 5.65 113.0 62.30 5.68 114.0 69.30 5.74 114.0 76.40 5.84 116.0 83.90 5.94 117.0 91.80 6.06 119.0 53.40 5.96 118.0 60.20 5.99 119.0 67.10 6.06 119.0 74.10 6.16 121.0 81.50 6.27 122.0 89.20 6.39 124.0 51.40 6.27 123.0 58.00 6.31 123.0 64.90 6.38 124.0 71.80 6.48 125.0 79.10 6.59 127.0 86.70 6.72 128.0 47.10 6.93 133.0 53.60 6.99 133.0 60.30 7.06 134.0 67.00 7.17 135.0 74.10 7.29 136.0 81.40 7.43 138.0 80 238.98 17.97 105.80 251.31 18.12 106.70 263.65 18.27 107.60 289.54 18.61 109.40 318.31 19.01 111.20 344.71 19.44 111.20 82.70 6.94 106.0 90.90 7.09 107.0 99.50 7.29 108.0 108.00 7.52 109.0 118.00 7.78 111.0 128.00 8.06 113.0 77.90 7.57 116.0 85.80 7.69 116.0 94.00 7.87 117.0 103.00 8.11 119.0 112.00 8.37 120.0 121.00 8.66 122.0 75.50 7.90 121.0 83.20 8.01 121.0 91.20 8.18 122.0 99.70 8.41 123.0 109.00 8.67 125.0 118.00 8.96 127.0 73.10 8.25 126.0 80.50 8.35 126.0 88.40 8.50 127.0 96.70 8.72 128.0 105.00 8.98 130.0 115.00 9.27 131.0 Air Temperature Entering Condenser (F) 85 95 100 115 232.12 18.76 111.20 244.32 18.87 111.20 256.51 18.98 111.20 282.07 19.28 113.00 309.33 20.05 114.80 338.71 20.47 116.60 217.96 18.98 118.40 229.73 20.22 118.40 241.50 21.45 118.40 266.17 21.84 120.20 286.68 22.25 122.00 320.76 22.71 123.80 199.02 23.38 125.60 212.47 23.58 125.60 225.91 23.77 125.60 249.69 24.20 122.00 274.90 24.66 131.00 302.17 25.11 129.20 181.25 26.92 137.30 192.37 27.15 137.75 203.49 27.39 138.20 225.24 27.93 135.50 249.40 28.71 141.80 271.24 29.36 142.70 TC kW SDT 30 TC kW SDT 35 TC kW SDT 40 TC kW SDT 45 TC kW SDT 50 TC kW SDT 25 TC kW SDT 30 TC kW SDT 35 TC kW SDT 40 TC kW SDT 45 TC kW SDT 50 TC kW SDT 38ARD024 SST (F) Air Temperature Entering Condenser (F) 80 85 95 100 105 115 85.00 6.64 101.0 93.30 6.81 102.0 102.00 7.01 103.0 111.00 7.24 104.0 121.00 7.49 106.0 130.00 7.76 108.0 25 38ARD016 SST (F) Air Temperature Entering Condenser (F) 80 85 95 100 105 115 38ARD028 SST (F) TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW 38ARD014 SST (F) Air Temperature Entering Condenser (F) 80 85 95 100 105 115 67.90 8.98 136.0 75.10 9.06 136.0 82.60 9.18 136.0 90.40 9.37 138.0 98.70 9.61 139.0 107.00 9.90 140.0 25 30 35 40 45 50 125 175.41 27.99 141.80 186.35 28.26 141.80 197.28 28.52 141.80 217.62 29.14 143.60 243.45 29.63 147.20 262.86 30.10 149.00 10 TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT TC kW SDT 80 120.3 7.6 109 126.3 7.67 110 132.4 7.73 111 145.0 7.87 113 159.1 8.04 115 172.1 8.22 117 Air Temperature Entering Condenser (F) 85 95 100 105 115 117.1 110.3 102.0 96.7 321.1 7.93 8.02 9.88 10.93 11.38 115 122 129 138 142 123.1 116.3 108.6 102.3 99.6 7.98 8.55 9.97 11.02 11.48 116 123 130 138 142 358.5 107.9 122.3 115.2 129.0 11.58 10.05 11.1 8.02 9.07 143 131 138 124 117 119.2 115.8 134.4 126.9 141.6 11.80 10.23 11.29 9.22 8.15 145 131 140 124 117 155.0 142.1 139.2 130.4 127.7 8.48 9.41 10.43 11.74 12.135 118 126 135 142 147 169.4 161.1 152.6 142.4 138.5 8.66 9.6 10.61 12.1 12.415 120 127 133 142 148 80 165.1 10.21 109 173.3 10.30 110 181.6 10.38 111 199.0 10.57 113 218.2 10.8 113 236.0 11.04 115 Air Temperature Entering Condenser (F) 85 95 100 105 115 160.8 151.4 140.3 133.2 129.6 10.66 10.78 13.28 14.69 15.30 113 122 129 138 142 168.9 159.7 149.3 140.8 137.1 10.72 11.49 13.39 14.80 15.43 114 122 130 138 142 177.1 167.9 158.3 148.4 144.6 10.78 12.19 13.5 14.91 15.56 115 122 131 138 143 194.2 184.5 174.3 163.9 543.4 10.95 12.39 13.75 15.17 15.86 117 124 131 138 144 212.6 197.2 191.2 179.3 175.6 11.39 12.64 14.01 15.78 16.31 118 126 135 140 146 232.3 221.1 209.5 195.7 190.4 11.63 12.9 14.26 16.25 16.68 120 127 133 142 148 80 Air Temperature Entering Condenser (F) 85 95 100 115 125 177.00 12.70 95.9 193.00 13.20 97.7 210.00 13.70 99.8 227.00 14.20 102.0 246.00 14.80 104.0 265.00 15.40 107.0 165.00 14.00 110.0 180.00 14.80 112.0 195.00 15.30 114.0 212.00 15.90 116.0 230.00 16.50 118.0 248.00 17.10 121.0 156.00 15.60 120.0 170.00 16.00 121.0 185.00 16.50 123.0 201.00 17.00 125.0 218.00 17.60 127.0 235.00 18.30 130.0 kW — Compressor Power SDT — Saturated Discharge Temperature (F) SST — Saturated Suction Temperature (F) TC — Gross Cooling Capacity (1000 Btuh) 151.00 16.30 125.0 165.00 16.70 126.0 179.00 17.10 128.0 195.00 17.60 130.0 211.00 18.20 132.0 229.00 18.90 134.0 137.00 18.40 139.0 150.00 18.80 140.0 163.00 19.10 142.0 177.00 19.60 143.0 192.00 20.10 145.0 208.00 20.80 147.0 123.00 19.40 148.0 138.00 20.00 150.0 151.00 20.50 151.0 165.00 21.00 153.0 179.00 21.50 154.0 194.00 22.10 156.0 Performance data 50Hz – Cont. COMBINATION RATINGS — ENGLISH 38ARZ007/40RM007 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 38ARZ007/40RM008 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 38ARZ008/40RM007 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 1800 57 57.2 57.20 3.67 56.4 56.40 3.90 54.8 54.80 4.35 54.0 54.00 4.61 53.1 53.10 4.86 51.4 51.40 5.38 50.89 50.89 5.54 62 58.5 54.50 3.69 57.5 54.00 3.92 55.7 53.00 4.36 54.7 52.50 4.62 53.7 51.90 4.87 51.7 50.80 5.38 51.10 50.47 5.53 67 63.1 45.40 3.77 62.0 45.00 3.99 59.9 44.20 4.44 58.8 43.70 4.70 57.7 43.30 4.95 55.5 42.40 5.46 54.84 42.13 5.61 72 68.4 35.80 3.86 67.3 35.40 4.09 65.1 34.60 4.54 63.9 34.10 4.79 62.6 33.70 5.05 60.2 32.90 5.56 59.48 32.66 5.71 2250 57 61.3 61.30 3.74 60.4 60.40 3.96 58.7 58.70 4.42 57.7 57.70 4.67 56.7 56.70 4.93 54.8 54.80 5.44 54.23 54.23 5.57 62 61.5 60.90 3.74 60.6 60.10 3.97 58.7 58.70 4.42 57.7 57.70 4.68 56.8 56.80 4.93 54.8 54.80 5.44 54.20 54.20 5.57 67 65.5 51.10 3.81 64.4 50.60 4.03 62.1 49.80 4.48 61.0 49.30 4.74 59.8 48.80 4.99 57.4 47.90 5.50 56.68 47.63 5.63 72 70.9 39.3 3.90 69.7 38.9 4.13 67.3 38.1 4.58 66.0 37.7 4.84 64.7 37.2 5.09 62.1 36.4 5.61 61.32 36.16 5.74 1800 57 68.3 68.30 4.81 67.4 67.40 5.11 65.4 65.40 5.71 64.4 64.40 6.03 63.3 63.30 6.36 61.2 61.20 7.01 60.57 60.57 7.17 62 72.6 61.50 4.85 71.4 60.90 5.15 68.9 59.70 5.74 67.6 59.10 6.07 66.2 58.40 6.40 63.6 57.10 7.06 62.82 56.71 7.23 67 79.0 52.00 4.92 77.7 51.40 5.22 75.0 50.30 5.82 73.6 49.70 6.15 72.2 49.10 6.49 69.3 47.90 7.15 68.43 47.54 7.32 72 85.7 42.20 5.00 84.3 41.70 5.30 81.5 40.60 5.91 80.0 40.00 6.25 78.5 39.50 6.59 75.5 38.30 7.27 74.60 37.94 7.44 Evaporator Air — Cfm 2400 Evaporator Air — Ewb (F) 57 62 67 72 61.8 61.9 65.6 70.9 61.80 61.80 52.30 40.00 3.75 3.75 3.81 3.90 60.9 61.0 64.5 69.7 60.90 60.90 51.90 39.60 3.97 3.98 4.03 4.13 59.2 59.2 62.2 67.3 59.20 59.20 51.00 38.80 4.43 4.43 4.48 4.58 58.2 58.2 61.0 66.0 58.20 58.20 50.50 38.40 4.68 4.68 4.74 4.83 57.2 57.2 59.9 64.7 57.20 57.20 50.00 38.00 4.94 4.94 4.99 5.09 62.1 57.5 55.3 55.3 37.10 49.10 55.30 55.30 5.60 5.50 5.46 5.46 61.32 56.78 54.73 54.73 36.83 48.83 54.73 54.73 5.75 5.65 5.62 5.62 Evaporator Air — Cfm 3000 Evaporator Air — Ewb (F) 57 62 67 72 65.6 65.6 67.8 73.0 65.60 65.6 59.0 44.4 3.81 3.81 3.85 3.94 64.7 64.7 66.6 71.7 64.70 64.7 58.5 44.0 4.04 4.04 4.07 4.16 62.7 62.7 64.3 69.2 62.70 62.7 57.6 43.2 4.49 4.49 4.52 4.62 61.6 61.6 63.0 67.8 61.60 61.6 57.0 42.8 4.75 4.75 4.78 4.87 60.6 60.6 61.8 66.5 60.60 60.6 56.5 42.3 5.01 5.01 5.03 5.13 58.5 58.5 59.3 63.8 58.50 58.5 55.4 41.5 5.53 5.52 5.54 5.64 62.99 57.87 58.55 57.87 41.26 57.87 55.07 57.87 5.77 5.67 5.65 5.66 Evaporator Air — Cfm 2400 Evaporator Air — Ewb (F) 57 62 67 72 74.9 76.8 82.9 89.6 74.90 70.80 59.00 46.50 4.88 4.89 4.96 5.05 73.8 75.5 81.5 88.1 73.80 70.20 58.40 46.00 5.17 5.19 5.27 5.35 71.6 72.9 78.7 85.1 71.60 68.80 57.30 44.90 5.77 5.79 5.87 5.96 70.4 71.6 77.1 83.5 70.40 68.10 56.70 44.30 6.11 6.12 6.20 6.30 69.2 70.2 75.6 81.9 69.20 67.30 56.10 43.80 6.44 6.46 6.54 6.64 66.8 67.4 72.4 78.7 66.80 65.80 54.90 42.60 7.11 7.12 7.21 7.33 66.08 66.08 7.28 11 66.56 65.35 7 29 . 71.44 54.54 7.38 77.74 42.24 7.50 3000 57 65.1 65.10 3.80 64.1 64.10 4.03 62.1 62.10 4.48 61.1 61.10 4.74 60.1 60.10 5.00 58.0 58.00 5.52 57.37 57.37 5.68 62 65.1 65.10 3.80 64.1 64.10 4.03 62.2 62.20 4.48 61.1 61.10 4.74 60.1 60.10 5.00 58.0 58.00 5.51 57.37 57.37 5.66 67 67.3 58.50 3.84 66.1 58.00 4.06 63.8 57.00 4.51 62.6 56.50 4.77 61.4 55.90 5.02 58.9 54.90 5.53 58.15 54.60 5.68 72 72.5 44.00 3.93 71.2 43.60 4.16 68.7 42.80 4.61 67.4 42.40 4.86 66.1 42.00 5.12 63.4 41.10 5.63 62.59 40.83 5.78 3750 57 68.6 68.6 3.86 67.5 67.50 4.09 65.4 65.4 4.55 64.3 64.3 4.80 63.2 63.2 5.06 61.0 61.0 5.58 60.34 60.34 5.71 62 68.6 68.6 3.86 67.5 67.50 4.09 65.4 65.4 4.54 64.3 64.3 4.80 63.2 63.2 5.06 61.0 61.0 5.58 60.34 60.34 5.71 67 69.4 65.6 3.88 68.3 65.00 4.10 65.9 63.8 4.55 64.7 63.0 4.81 63.4 62.3 5.06 61.0 60.8 5.57 60.28 60.35 5.70 72 74.2 49.2 3.96 72.9 48.80 4.19 70.3 47.9 4.64 68.9 47.5 4.89 67.5 47.1 5.15 64.8 46.2 5.66 63.99 45.93 5.79 3000 57 79.4 79.40 4.93 78.2 78.20 5.23 75.9 75.90 5.83 74.6 74.60 6.17 73.3 73.30 6.50 70.7 70.70 7.17 69.92 69.92 7.34 62 80.0 78.30 4.93 78.7 77.40 5.23 76.1 75.60 5.83 74.7 74.50 6.17 73.3 73.30 6.50 70.6 70.60 7.17 69.79 69.79 7.34 67 85.5 65.50 5.00 84.0 64.90 5.30 81.0 63.80 5.90 79.4 63.10 6.24 77.8 62.50 6.57 74.5 61.30 7.25 73.51 60.94 7.42 72 92.1 50.40 5.08 90.5 49.80 5.38 87.4 48.80 5.99 85.7 48.20 6.34 84.1 47.70 6.68 80.7 46.50 7.36 79.68 46.14 7.53 7 38ARZ008/40RM008 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW TC 118.4 SHC kW 72 89.1 45.80 5.04 87.6 45.20 5.34 84.8 44.20 5.96 83.2 43.60 6.30 81.6 43.00 6.64 78.4 41.90 7.32 77.44 41.57 7.52 Evaporator Air — Cfm 3000 Evaporator Air — Ewb (F) 57 62 67 72 80.2 80.6 85.7 92.3 80.20 79.10 66.10 50.80 4.93 4.94 5.00 5.08 79.0 79.3 84.3 90.8 79.00 78.20 65.60 50.30 5.23 5.24 5.30 5.39 76.6 76.7 81.4 87.8 76.60 76.40 64.50 49.30 5.84 5.84 5.91 6.00 75.3 75.4 79.8 86.1 75.30 75.20 63.90 48.70 6.17 6.18 6.25 6.34 74.0 74.1 78.2 84.4 74.00 74.10 63.30 48.10 6.51 6.51 6.58 6.68 71.5 71.4 75.0 80.9 71.50 71.40 62.10 46.90 7.19 7.19 7.26 7.36 70.75 70.59 74.04 79.85 70.75 70.59 61.74 46.54 7.39 7.39 7.46 7.56 72 94.6 52.30 5.11 93.0 51.70 5.42 89.8 50.60 6.03 88.0 50.10 6.37 86.3 49.50 6.71 82.7 48.30 7.40 Evaporator Air — Cfm 4000 Evaporator Air — Ewb (F) 57 62 67 72 87.9 87.9 90.8 97.2 87.90 87.90 78.50 58.80 5.03 5.03 5.06 5.14 86.6 86.6 89.2 95.5 86.60 86.60 77.90 58.30 5.33 5.33 5.37 5.45 83.8 83.8 86.1 92.2 83.80 83.80 76.60 57.30 5.94 5.94 5.98 6.07 82.4 82.4 84.3 90.3 82.40 82.40 75.90 56.60 6.28 6.28 6.32 6.41 80.9 80.9 82.6 88.5 80.90 80.90 75.20 56.00 6.62 6.63 6.66 6.75 78.0 78.0 79.2 84.7 78.00 78.00 73.70 54.80 7.31 7.31 7.34 7.43 Evaporator Air — Cfm 3000 Evaporator Air — Ewb (F) 57 62 67 72 96.6 99.8 107.0 115.0 96.60 90.10 74.90 59.20 6.88 6.96 7.14 7.35 95.2 98.1 105.0 113.0 95.20 89.30 74.20 58.50 7.20 7.27 7.45 7.67 92.5 94.8 102.0 110.0 92.50 87.60 72.80 57.20 7.84 7.89 8.09 8.31 91.0 93.0 99.9 108.0 91.00 86.60 72.00 56.40 8.19 8.23 8.42 8.65 89.4 91.1 97.8 105.0 89.40 85.60 71.20 55.60 8.53 8.57 8.75 8.98 86.4 87.5 93.8 101.0 86.40 83.70 69.50 54.10 9.22 9.25 9.42 9.66 2250 57 74.1 74.10 4.87 73.0 73.00 5.17 70.9 70.90 5.76 69.7 69.70 6.10 68.6 68.60 6.43 66.3 66.30 7.09 65.61 65.61 7.29 62 76.4 69.40 4.89 75.1 68.70 5.19 72.6 67.40 5.78 71.2 66.70 6.11 69.8 66.00 6.45 67.1 64.60 7.11 66.29 64.18 7.31 67 82.5 57.90 4.96 81.1 57.30 5.26 78.3 56.20 5.86 76.8 55.60 6.20 75.3 55.00 6.53 72.3 53.80 7.21 71.40 53.44 7.41 38ARZ008/40RM012 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW 3000 57 82.4 82.40 4.96 81.1 81.10 5.26 78.7 8.70 5.87 77.3 77.30 6.21 75.9 75.90 6.54 73.2 73.20 7.22 62 82.7 81.60 4.96 81.4 80.60 5.26 78.7 78.60 5.87 77.3 77.30 6.21 76.0 76.00 6.55 73.2 73.20 7.22 67 87.9 8.20 5.03 86.3 67.60 5.33 83.3 66.40 5.93 81.6 65.08 6.27 79.9 65.10 6.61 76.6 63.80 7.28 38ARZ012/40RM008 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW TC 118.4 SHC kW 2250 57 88.7 88.40 6.71 87.4 87.20 7.04 84.8 84.80 7.68 83.5 83.50 8.03 82.2 82.20 8.38 79.5 79.50 9.07 62 94.4 78.50 6.83 92.9 77.80 7.15 89.8 76.30 7.78 88.1 75.40 8.12 86.4 74.50 8.46 83.0 72.80 9.14 67 102.0 66.30 7.01 101.0 65.60 7.33 97.3 64.20 7.96 95.4 63.40 8.29 93.6 62.60 8.63 89.8 61.00 9.31 72 110.0 54.00 7.22 109.0 53.30 7.54 105.0 51.90 8.17 103.0 51.20 8.51 101.0 50.40 8.84 97.1 48.80 9.51 78.69 81.98 88.66 95.93 85.50 86.42 92.60 78.69 72.29 60.52 48.32 85.50 83.13 68.99 9.24 9.31 48 9.68 9.39 9.42 9.59 8 12 3750 57 84.3 84.30 4.98 83.1 83.10 5.29 80.5 80.50 5.90 79.2 79.20 6.23 77.8 77.80 6.57 75.0 75.00 7.25 74.16 74.16 7.45 62 84.3 84.30 4.98 83.0 83.00 5.28 80.5 80.50 5.89 79.1 79.10 6.23 77.7 77.70 6.57 75.0 75.00 7.25 74.19 74.19 7.45 67 88.0 73.70 5.03 86.4 73.10 5.33 83.4 71.90 5.94 81.8 71.20 6.27 80.1 70.50 6.61 76.9 69.20 7.29 75.94 68.81 7.49 72 94.4 55.40 5.11 92.8 54.90 5.41 89.6 53.90 6.03 87.8 53.30 6.37 86.1 52.80 6.71 82.6 51.70 7.39 81.55 51.37 7.59 5000 57 91.7 91.70 5.07 90.3 90.30 5.38 87.4 87.40 5.99 85.8 85.80 6.34 84.3 84.30 6.68 81.2 81.20 7.37 62 91.7 91.70 5.07 90.2 90.20 5.38 87.3 87.30 5.99 85.8 85.80 6.34 84.2 84.20 6.68 81.1 81.10 7.37 67 92.9 87.10 5.09 91.3 86.40 5.39 88.1 84.80 6.01 86.4 83.80 6.35 84.7 82.80 6.69 81.3 80.80 7.37 72 98.8 64.90 5.16 97.1 64.30 5.47 93.7 63.30 6.09 91.7 62.70 6.43 89.8 62.10 6.77 86.0 60.90 7.46 3750 57 102.0 102.00 7.02 101.0 101.00 7.34 97.8 97.80 7.97 96.1 96.10 8.32 94.5 94.50 8.66 91.1 91.10 9.34 62 104.0 99.60 7.04 102.0 98.50 7.36 98.5 96.50 7.99 96.6 95.20 8.33 94.8 94.00 8.67 91.1 91.10 9.34 67 110.0 82.80 7.22 109.0 82.10 7.53 105.0 80.70 8.16 103.0 79.80 8.50 101.0 79.00 8.83 96.3 77.30 9.50 72 118.0 63.90 7.43 116.0 63.30 7.75 113.0 61.90 8.39 110.0 61.10 8.73 108.0 60.30 9.06 104.0 58.80 9.73 99.80 90.08 89.99 94.89 102.80 53.65 90.08 90.23 76.79 58.35 9.83 9.51 9.51 9.67 9.90 Performance data 50Hz – Cont. 38ARZ012/40RM012 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW TC 118.4 SHC kW 72 118.0 60.80 7.43 116.0 60.10 7.75 112.0 58.70 8.39 110.0 57.90 8.72 108.0 57.10 9.05 103.0 55.40 9.71 101.50 54.89 9.91 Evaporator Air — Cfm 4000 Evaporator Air — Ewb (F) 57 62 67 72 107.0 108.0 114.0 122.0 107.0 106.0 88.10 67.50 7.13 7.15 7.31 7.54 105.0 106.0 112.0 120.0 105.0 104.0 87.40 66.80 7.45 7.46 7.63 7.85 102.0 102.0 108.0 116.0 102.0 102.0 85.90 65.40 8.09 8.09 8.26 8.49 100.0 100.0 106.0 114.0 100.0 100.0 85.00 64.60 8.43 8.43 8.59 8.83 98.6 98.5 104.0 111.0 98.60 98.50 84.10 63.80 8.78 8.77 8.93 9.16 95.0 94.7 99.2 107.0 95.00 94.70 82.40 62.10 9.46 9.44 9.59 9.83 93.92 93.56 97.76 105.80 93.92 93.56 81.89 61.59 9.66 9.64 9.79 10.03 72 124.0 66.10 7.59 122.0 65.40 7.91 118.0 63.90 8.55 115.0 63.00 8.88 113.0 62.10 9.21 108.0 60.30 9.87 Evaporator Air — Cfm 5000 Evaporator Air — Ewb (F) 57 62 67 72 114.0 114.0 120.0 128.0 114.00 114.00 97.60 73.70 7.32 7.32 7.46 7.70 112.0 112.0 117.0 126.0 112.00 112.00 96.70 73.00 7.63 7.63 7.78 8.02 109.0 109.0 113.0 121.0 109.0 109.0 95.10 71.50 8.27 8.27 8.41 8.66 107.0 107.0 111.0 119.0 107.00 107.00 94.10 70.60 8.61 8.61 8.74 8.99 105.0 105.0 108.0 116.0 105.00 105.00 93.10 69.70 8.95 8.95 9.07 9.32 100.0 100.0 103.0 111.0 100.00 100.00 91.10 68.00 9.63 9.63 9.73 9.98 3000 57 99.3 99.30 6.94 97.9 97.90 7.26 95.0 95.00 7.90 93.4 93.40 8.25 91.8 91.80 8.59 88.5 88.50 9.28 87.51 87.51 9.49 62 102.0 92.70 7.01 101.0 91.90 7.33 97.1 90.10 7.95 95.2 89.10 8.29 93.3 88.10 8.63 89.5 86.10 9.30 88.36 85.50 9.50 67 110.0 77.20 7.21 108.0 76.40 7.52 104.0 74.90 8.15 102.0 74.00 8.48 100.0 73.20 8.81 95.8 71.40 9.47 94.54 70.86 9.67 38ARZ012/40RM014 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW 38ARD014/40RM014 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 122 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 3750 57 106.0 106.00 7.12 105.0 105.00 7.43 101.0 101.00 8.07 99.6 99.60 8.41 97.8 97.80 8.75 94.1 94.10 9.42 62 108.0 103.00 7.16 106.0 101.00 7.47 102.0 99.40 8.10 100.0 98.10 8.43 98.3 96.80 8.77 94.2 94.20 9.43 67 116.0 85.10 7.36 114.0 84.30 7.67 110.0 82.70 8.30 107.0 81.70 8.63 105.0 80.80 8.96 100.0 78.90 9.61 3750 62 126 112 7.68 124 111 8.16 120 109 9.18 116 106 9.73 114 105 10.3 110 103 11.5 107.9 101.5 12.1 105 99.6 12.8 67 136 93.1 7.73 134 92.2 8.21 130 90.5 9.23 127 89.1 9.73 124 88.2 10.3 119 86.2 11.6 116.4 85.3 12.2 113 84 12.9 72 149 73.8 7.81 147 73 8.29 141 71.4 9.28 138 70.2 9.82 136 69.3 10.4 130 67.5 11.6 127.0 66.5 12.2 123 65.2 12.9 Evaporator Air — Cfm 5000 Evaporator Air — Ewb (F) 62 67 72 133 142.5 155 127 106.6 82.4 7.71 7.762 7.84 131 140.4 153 126 105.6 81.7 8.19 8.229 8.31 127 138.0 148 122 100.0 79.9 9.22 9.3 9.31 124 131.8 143 119 99.98 78.7 9.73 9.824 9.82 122 128.7 140 117 99.01 77.8 10.3 10.31 10.4 117 123.6 135 113 97.09 75.9 11.6 11.57 11.7 114.9 120.9 131.6 110.9 95.0 74.9 12.2 12.2 12.3 112 117.2 127 108 92.24 73.6 12.9 12.94 13 5000 57 112.0 112.00 7.27 111.0 111.00 7.59 107.0 107.00 8.23 105.0 105.00 8.57 103.0 103.00 8.91 99.2 99.20 9.59 98.06 98.06 9.79 62 112.0 112.0 7.27 110.0 110.0 7.59 107.0 107.0 8.23 105.0 105.0 8.57 103.0 103.0 8.91 99.2 99.20 9.58 98.06 98.06 9.78 67 117.0 98.20 7.39 115.0 97.30 7.70 111.0 95.60 8.34 108.0 94.70 8.67 106.0 93.70 9.00 101.0 91.70 9.66 99.50 91.10 9.86 72 125.0 73.70 7.60 123.0 73.00 7.92 118.0 71.60 8.57 116.0 70.80 8.90 113.0 69.90 9.23 109.0 68.30 9.90 107.80 67.82 10.10 6250 57 119.0 119.00 7.45 117.0 117.00 7.77 113.0 113.00 8.42 111.0 111.00 8.75 109.0 109.00 9.09 105.0 105.00 9.77 62 119.0 119.00 7.45 117.0 117.00 7.77 113.0 113.0 8.41 111.0 111.00 8.75 109.0 109.00 9.09 105.0 105.00 9.77 67 122.0 108.00 7.53 120.0 108.00 7.85 116.0 106.0 8.48 113.0 104.00 8.81 111.0 103.00 9.14 106.0 101.00 9.80 72 130.0 80.70 7.76 128.0 80.00 8.08 124.0 78.50 8.72 121.0 77.60 9.06 118.0 76.80 9.39 113.0 75.10 10.10 6250 62 140 135 7.77 138 133 8.23 134 129 9.25 131 126 9.82 129 124 10.4 124 119 11.6 121.4 116.9 12.2 118 114 12.9 67 147 120 7.78 144 119 8.25 139 117 9.26 135 115 9.82 133 114 10.4 127 111 11.6 124.0 109.7 12.2 120 108 12.9 72 159 90.4 7.87 156 89.6 8.34 151 87.9 9.34 146 86.5 9.92 144 85.6 10.41 138.0 83.7 11.67 134.6 82.7 12.3 130 81.3 13.03 19 13 38ARD016/40RM016 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 122 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 38ARD024/40RM024 Temp (F) Air Entering Condenser (Edb) 80 85 95 100 105 115 118.4 122 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 72 207 99.9 11.3 204 98.7 11.7 197 96 12.7 191 94.1 13.2 186 92.7 13.8 177 89.5 14.8 172.3 88.0 15.3 166 85.9 15.9 Evaporator Air — Cfm 6000 Evaporator Air — Ewb (F) 62 67 72 187 199.4 215 172 135.9 111 10.8 11.06 11.3 184 196 212 170 134.9 109 11.3 11.54 11.8 177 192.0 204 165 131.0 107 12.2 12.50 12.9 172 182.9 197 162 130.2 105 12.8 12.98 13.4 169 178.5 193 159 128.2 104 13.3 13.56 13.9 161 169.6 183 153 125.2 100 14.3 14.62 15 156.7 165.1 177.9 149.6 123.6 98.6 14.8 15.1 15.5 151 159.1 171 145 121.5 96.7 15.5 15.67 16.1 72 237.0 115.1 14.9 233.0 114.2 15.5 224.0 110.4 16.7 219.0 109.4 17.4 214.0 107.6 17.9 204.0 103.8 19.2 199.7 102.6 19.8 194.0 101.0 20.6 Evaporator Air — Cfm 7000 Evaporator Air — Ewb (F) 62 67 72 209.5 223.5 241.0 187.8 156.6 121.7 14.1 14.5 15.1 205.5 220.0 237.0 185.4 155.2 120.8 14.6 15.1 15.6 198.0 211.0 227.5 180.7 151.9 117.0 15.8 16.3 16.9 194.5 206.5 222.5 178.3 150.0 116.0 16.5 16.9 17.5 190.5 201.5 217.5 175.5 148.1 114.2 17.1 17.5 18.1 182.5 187.6 207.0 169.4 140.5 110.4 18.5 20.0 19.4 179.1 184.4 202.5 166.7 138.9 109.2 19.1 20.5 20.0 174.5 180.2 196.5 163.2 136.8 107.6 19.9 21.1 20.8 72 314.7 168.9 20.2 309.5 167.6 21.0 297.1 162.3 22.0 290.6 161 23.4 284.0 158.4 24.2 275.7 153.1 26.0 270.8 152.2 26.8 264.3 151.1 27.8 Evaporator Air — Cfm 8,000 Evaporator Air — Ewb (F) 62 67 72 276.6 293.3 315.2 268.7 224.3 172.3 19.0 19.6 20.3 271.5 288.2 310.1 264.9 223.0 171.1 19.7 20.3 21.1 261.2 276.6 297.2 257.3 218.0 166.0 20.7 21.1 22.1 257.3 270.2 290.8 253.5 215.4 164.7 22.2 22.7 23.5 252.2 263.7 284.3 248.4 212.9 162.2 23.1 23.6 24.3 246.7 257.2 275.6 243 199.3 157.1 25.0 25.3 26.1 243.2 252.6 270.5 239.5 196.9 156.1 25.9 26.1 26.9 238.5 246.5 263.7 234.9 193.8 154.8 27.0 27.2 28.0 4500 62 177 149 10.6 175 148 11.1 168 145 12 163 142 12.5 159 141 13.1 152 137 14.1 148.1 134.9 14.6 143 132 15.2 67 191.5 125.1 10.87 188.2 124 11.35 181.4 120.8 12.31 175.2 119.1 12.88 171.8 117 13.37 163 113.9 14.42 159.0 112.3 14.9 153.6 110.1 15.48 6,000 62 204.0 175.5 13.9 200.0 173.6 14.5 193.0 169.8 15.7 189.0 167.9 16.3 185.0 166.1 17.0 177.0 161.3 18.3 173.6 159.3 18.9 169.0 156.6 19.7 67 219.0 146.2 14.4 216.0 144.4 14.9 207.0 141.5 16.2 203.0 139.6 16.8 198.0 137.7 17.4 189.0 134.9 18.8 185.1 133.3 19.4 180.0 131.1 20.2 38ARD028/40RM028 Temp (F) Air Entering Condenser (Edb) TC 80 SHC kW TC 85 SHC kW TC 95 SHC kW TC 100 SHC kW TC 105 SHC kW TC 115 SHC kW TC 118.4 SHC kW TC 122 SHC kW 20 7000 62 273.6 260.5 18.8 268.4 257.2 19.6 258.6 252.4 20.6 254 247.4 22.1 248.8 243.5 23.0 243.1 239.7 24.8 239.5 237.0 25.6 234.7 233.3 26.7 67 291.9 217.3 19.5 287.3 215.3 20.2 275.5 210.8 21.0 269.7 208.1 22.6 263.1 205.5 23.5 256.4 192.7 25.3 252.0 191.3 26.1 246.1 189.5 27.2 LEGEND Edb — Entering Dry Bulb Ewb — Entering Wet Bulb kW — Compressor Motor Power Input 7500 62 195 184 11 193 182 11.4 186 176 12.4 181 172 13 176 168 13.5 169 160 14.6 164.7 156.6 15.1 159 152 15.7 67 205 160 11.2 202 158 11.6 194 155 12.6 187 153 13.2 183 151 13.7 174 148 14.7 168.9 145.9 15.2 162 143 15.8 8000 62 215.0 200.0 14.2 211.0 197.2 14.8 203.0 191.5 16.0 200.0 188.7 16.6 196.0 184.9 17.3 188.0 177.4 18.7 184.6 174.1 19.3 180.0 169.8 20.2 67 228.0 167.0 14.7 224.0 166.1 15.2 215.0 162.3 16.4 210.0 160.4 17.0 205.0 158.5 17.7 196.0 154.7 19.0 191.7 153.1 19.6 186.0 151.0 20.4 72 245.0 128.3 15.2 241.0 127.4 15.8 231.0 123.6 17.0 226.0 122.7 17.6 221.0 120.8 18.2 210.0 117.0 19.5 205.3 115.8 20.1 199.0 114.2 20.9 9,000 62 282.4 276.3 19.2 277.9 272.5 20.0 267.6 263.6 21.0 263.1 259.2 22.5 258.0 254.1 23.3 252.0 248.2 25.1 248.2 244.5 26.0 243.2 239.5 27.1 SHC — Sensible Heat Capacity (kW) Gross TC — Total Capacity (kW) Gross 14 72 221 120.8 11.44 217 119.8 12.02 208 117.7 12.98 202 114.9 13.46 197 113.9 14.04 187 111 15.10 182.3 109.3 15.6 176 107.0 16.15 67 296.6 237.6 19.7 291.4 235.7 20.5 279.8 230.6 21.3 273.4 228.1 22.8 267.0 225.6 23.7 259.8 210.8 25.5 255.2 209.3 26.3 249.1 207.4 27.3 72 318.4 180.6 20.4 313.3 179.3 21.2 300.4 174.2 22.2 294 173.0 23.6 286.9 170.4 24.5 278.2 165.3 26.2 273.1 164.1 27.0 266.4 162.5 28.0 Application data Operating limits – SI (English) Maximum Outdoor Temperature Minimum Outdoor Ambient Minimum Return-Air Temperature Maximum Return-Air Temperature Normal Acceptable Saturation Suction Temperature Range Maximum Discharge Temperature Minimum Discharge Superheat 52 C (125 F) LIQUID LINE DATA — 38ARD014-028 UNITS See Minimum Outdoor-Air Operating Temperature table below. UNIT 38AR 13 C (55 F) 38ARZ007-012 38ARD014-028 35 C (95 F) 16 C (60 F) For refrigerant lines longer than lineal ft, a liquid line solenoid valve installed at the indoor unit and a suction accumulator are required. Refer to the Refrigerant Specialties Part Numbers table. For applications with liquid lift greater than m (0 ft), use /-in. liquid line where / in. is shown; use /-in. liquid line where / in. is shown. The maximum liquid lift is m (0 ft). REFRIGERANT PIPING SIZES MAXIMUM REFRIGERANT CHARGE Z007 Z008 Z012 D014 D016 D024 D028 UNIT 38AR kg 7.7 15.5 15.5 (2)7.7 (2) 15.5 (2) 15.5 (2) 12.5 MINIMUM OUTDOOR-AIR OPERATING TEMPERATURE UNIT 38AR 38ARZ007-012 38ARD014-024 38ARD028 UNIT 38ARZ007 38ARZ008 38ARZ012 38ARD014 38ARD016 38ARD024 38A RD028 Z007 Z008 Z012 D014 D016 D024 UNIT 38AR COND TEMP C (F) MINIMUM OUTDOOR TEMP C (F) 32 (90) 10 (50) 32 (90) 15 (59) Std LIQUID LINE SOLENOID VALVE (LLSV) 1/2 200RB5T4M Qty 2 5/8 1/2 5/8 5/8 D028 0–7.6(0-25) L 3/8 3/8 1/2 1/2 1/2 1/2 S 1 1/8 1 1/8 1 3/8 1 1/8 1 3/8 1 3/8 0–4 (0-13.1 ) L 5/8 S 1 3 /8 LINEAR LENGTH OF PIPING — M (FT) 7.6–15.2(25-50) 15.2–22.4(50-75) 22.4–30.5(75-100) Line Size (in. OD) L S L S L S 3/8 1 1/8 3/8 1 1/8 3/8 1 1/8 1/2 1 1/8 1/2 1 1/8 1/2 1 3/8 1/2 1 3/8 1/2 1 3/8 1/2 1 3/8 1/2 1 1/8 1/2 1 1/8 1/2 1 1/8 1/2 1 3/8 1/2 1 3/8 5/8 1 3/8 1/2 1 3/8 5/8 1 3/8 5/8 1 3/8 LINEAR LENGTH OF PIPING — M (FT) 4-10 (13.1-32.8 ) 10-22 (32.8-72.2) 22–30.5(72.2-100) Line Size (in. OD) L S L S L S 7/8 1 5/8 5/8 1 5/8 5/8 1 5/8 LEGEND L — Liquid Line S — Suction Line NOTES: 1. Pipe sizes are based on a 2qF loss for liquid and suction lines. 2. Pipe sizes are based on the maximum linear length, shown for each column, plus a 50% allowance for fittings. 3. Charge units with R-22 refrigerant in accordance with unit installation instructions. REFRIGERANT SPECIALTIES PART NUMBERS LIQUID LINE SIZE (in.) 3/8 3/8 1/2 1/2 1/2 1.1 (2) It is recommended that the refrigerant piping for all commercial split systems include a liquid line solenoid valve, a liquid line filter drier and a sight glass. Liquid line R-22 48.8 (7) IMPORTANT: Do not bury refrigerant piping underground. 135 C (275 F) lb 17.3 34.2 34.2 (2)17.3 (2)34.2 (2)34.2 (2)27.5 18.2 (60) LIQUID LINE Max Allow. Max Allow. Pressure Drop Temp Loss kPa (psi) C(°F) Refrigerant piping -4 to 13 C (25 to 55 F) NOTES: . Select air handler at no less than 0 L/s per kW (00 cfm/ton) (nominal condensing unit capacity). . Total combined draw of the field-supplied liquid line solenoid valve and air handler fan contactor must not exceed va. If the specified va must be exceeded, use a remote relay to control the load. UNIT 38AR MAX ALLOW. LIFT m(ft) LLSV COIL SIGHT GLASS FILTER DRIER SUCTION LINE ACCUMULATOR 200RB5T4M 200RB5T4M 200RB5T4M 200RB6T4M 200RB5T4M Qty 2 AMG-24/50-60 AMG-24/50-60 AMG-24/50-60 AMG-24/50-60 AMG-24/50-60 Qty 2 AMI1TT3 AMI1TT3 AMI1TT4 AMI1TT4 AMI1TT4 Qty 2 P502-8304S P502-8304S P502-8304S P502-8307S P502-8304S Qty 2 S-7063S S-7063S S-7063S S-7063 S-7063S Qty 2 200RB5T5M Qty 2 AMG-24/50-60 Qty 2 AMI1TT5 Qty 2 P502-8304S Qty 2 S-7063S Qty 2 200RB6T4M Qty 2 200RB6T5M Qty 2 200RB6T5M Qty 2 AMG-24/50-60 Qty 2 AMG-24/50-60 Qty 2 AMG-24/50-60 Qty 2 AMG-24/50-60 Qty 2 AMI1TT4 Qty 2 AMI1TT5 Qty 2 AMI1TT5 Qty 2 AMI1TT5 Qty 2 P502-8304S Qty 2 P502-8307S* Qty 2 P502-8307S* Qty 2 P502-8307S* Qty 2 S-7063S Qty 2 S-7063S Qty 2 S-7063S Qty 2 S-7063S Qty 2 1 15 Typical wiring schematic 38ARZ 400V 2 16 Typical wiring schematic 38ARD 400V 17 3 Typical wiring schematic 38ARD ( Cont. ) Component Arrangement Control Box 4 18 Typical wiring schematic 38ARD-028 400V 19 25 Typical wiring schematic 38ARD-028 400V ( Cont. ) Component Arrangement Control Box 6 20 40RM007-034 6-25 Nominal Tons 50 Hz Model number nomenclature - 40RM 4 0 R M - 0 1 6 S D 40RM B 5 1 E D Factory-Installed Options Commercial Packaged Air Handler Cooling Coil - 0 ED Painted, Standard Motor and Standard Drive FD Painted, Standard Motor and Medium-Static Drive (Not available for 016-028 50 Hz units) RD Painted, Alternate Motor and Medium-Static Drive (Available for 50 Hz sizes 016,024,028 only) WD Painted, Alternate Motor and High-Static Drive Direct Expansion Nominal Capacity 007 6 (21) 008 7-1/2 (26) 012 10 (35) 014 12-1/2 (43) Tons (kW) 016 15 (52) 024 20 (70) 028 25 (87) 034 30 (105) S: SAMCO D: Double Skin Expansion Device B Thermostatic Expansion Valves (40RM ) Voltage Designation (V-Ph-Hz) 8 9 230-3-50 400-3-50 Packaging 1 Standard Domestic 3 Export Revision Number 0 Original Model Quality Assurance 21 27 Physical data (Cont.) 40RM - ENGLISH UNIT 40RM NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit (Double skin) with TXV Plenum FANS Qty...Diam. (in.) Nominal Airflow (cfm) Airflow Range (cfm) Nominal Motor Hp (Standard Motor)* 230-3-50, 400-3-50 Motor Speed (rpm) 230-3-50, 400-3-50 007SD 6 008SD 71/2 012SD 10 014SD 121/2 016SD 15 024SD 20 028SD 25 034SD 30 448 97 452 97 472 97 804 140 819 140 824 140 1188 180 1198 180 1...15 1...15 1...15 2...15 2...15 2...15 2...18 2...18 2400 3000 4000 5000 6000 8000 10,000 12,000 1800-3000 2250-3750 3000-5000 3750-6250 4500-7500 6000-10,000 7500-12,500 9000-15,000 2.4 2.4 2.9 6.67 1 12 3...15 PIPING CONNECTIONS Quantity...Size (in.) DX Coil - Suction (ODF) DX Coil - Liquid Refrigerant (ODF) 1...11/8 1...11/8 1...5/8 5.0 7.5 10.0 3.5/3.5 4.5/4.5 5.0/5.0 Enhanced Copper Tubes, Aluminum Sine-Wave Fins 435 10.0 13.25 17.67 19.88 24.86 2 2 2 2 2 Face...50/50 9 9 12 13 15 3...17 3...15 3...15 3...17 3...15 29.83 2 R-22 3.0 3.0 8.33 1 15 3...15 1.5/1.5 2...11/8 Condensate (PVC) 2.0/2.0 2...11/8 2.5/2.5 2...11/8 2...11/8 2...5/8 2...13/8 18 3...15 2...13/8 1...11/4 ODM/1 IDF FILTERS DX TXV - 2.9 1425 REFRIGERANT Operating charge (lb) (approx per circuit)² DIRECT-EXPANSION COIL Max Working Pressure (psig) Face Area (sq ft) No. of Splits Split Type...Percentage No. of Circuits per Split Rows...Fins/in. Quantity...Size (in.) Access Location 2.9 Washable 4...16 x 24 x 1 - Factory Supplied 4...16 x 20 x 1 4...16 x 24 x 1 Front 4...20 x 24 x 1 4...20 x 25 x 1 LEGEND Direct Expansion Thermostatic Expansion Valve *Refer to alternate Fan Motor Data table, page 49, for alternate motor data. ²Units are shipped without refrigerant charge. 29 22 Options and accessories Factory-installed Return-air grille provides a protective barrier over the return-air opening and givesa finished appearanceto units installed in the occupied space. Accessory is availableun painted or painted. Subbase provides a stable, raised platform and room for condensatedrain trap connection for verticalfloor-mounted units. Accessoryis availableunpainted or painted. Over head suspension package includes necessary brack ets to support units in horizontal ceiling installations. CO 2 sensors can be used in conjunction with the econ omizer accessoryto help meet indoor air quality require ments. The sensor signals the economizer to open when the CO2 level in the spaceexceedsthe set point. A Carrier Comfort Systemprogrammable thermostat can be usedto override the sensorif the outsideair temperature is too high or too low. Carrier's line of ther mostats provide both program mable and non-programmable capability with the new Debonair line of commercial programmable thermostats, the TEMP System controls offer communication capabil ity with stagedheating and cooling, the Commercial Elec tronic thermostats provide 7-day programmable capability for economicalapplications,while the Non-Programmable thermostatsoffer a multitude of stagedheating and cooling subbaseoptions. Condensate drain trap includesan overflow shutoff switch that can be wired to turn off the unit if the trap becomes plugged. Kit also includesa wire harnessthat can be con nected to an alarm if desired. The transparent trap is de signed for easy serviceand maintenance. options Alternate fan motors and drives are available to pro vide the widest possiblerange of performance. Field-installed accessories Electric r esistance heat coils have an open-wire design and are mounted in a rigid frame. Safety cutouts for high temperature conditions are standard. Terminal block for single-point power connection is included. Economizer (enthalpy contr olled) provides ventilation air and ``free'' cooling if outside ambient temperature and humidity are suitable. Can also be used with CO2 sensors to help meet indoor air quality requirements. Discharge plenum directs the air discharge directly into the occupied space;integral horizontal and vertical louvers enable redirection of airflow. Accessory is available un painted or painted. Field assemblyrequired. Standard units available from the factory are in Double skin. 30 23 Options and accessories (cont) CARRIER THERMOSTATS DEBONAIR COMMERCIAL PROGRAMMABLE THERMOSTAT COMMERCIAL ELECTRONIC THERMOSTAT ® Pm AUTO COOL HEAT TEMP SYSTEM THERMOSTAT NON-PROGRAMMABLE THERMOSTAT H C 31 24 40RM WITH DISCHARGE PLENUM, RETURN-AIR GRILLE AND SUBBASE DISCHARGE PLENUM RETURN-AIR GRILLE SUBBASE FAN COIL UNIT 40RM WITH ECONOMIZER 40RM WITH CONDENSATE TRAP ECONOMIZER 32 25 Dimensions 40RM007SD-012SD UNIT 40RM007SD 40RM008SD 40RM012SD UNIT WEIGHT lb (kg) 448 (203) 452 (205) 472 (214) All the above mentioned weights are for double skin units. TXV - Thermostatic Expansion Valve NOTES: 1. Dimensions in [ millimeters. 2. ] are in Direction of air¯ow . 3. Recommended clearance: · Rear: 39(76.2 mm) (28-69[762 mm] with electric heat accessory) · Front: 28-69 (762 mm) · Right side: 28-69 (762 mm) · Left Side: 28-69 (762 mm) · Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. 26 33 Dimensions (cont) 40RM014SD-024SD TXV - Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. UNIT 3. Recommended clearance: · Rear: 39 (76.2 mm) (28-69 [762 mm] with electric heat accessory) · Front: 28-69 (762 mm) · Right side: 28-69 (762 mm) · Left Side: 28-69 (762 mm) · Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. UNIT 40RM014SD 40RM016SD 40RM024SD All the weights men tioned in the table are for double skin units. 4 27 UNITWEIGHT lb (kg) 804 (364) 819 (371) 824 (373) Dimensions (cont) 40RM028SD,034SD TXV - Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance: · Rear: 39 (76.2 mm) · Front: 28-69 (762 mm) · Right side: 28-69 (762 mm) · Left Side: 28-69 (762 mm) · Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. UNIT 40RM028SD 40RM034SD UNIT WEIGHT lb (kg) 1188 (538) 1198 (542) All the above mentioned weights are for double skin units. 5 28 OVERHEAD SUSPENSION ACCESSORY UNIT SIZES 007-012 UNIT SIZES 014-024 UNIT SIZES 028,034 NOTE: Dimensions in [ 6 29 ] are millimeters. Dimensions (cont) PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES UNIT SIZES 007-012 UNIT SIZES 014-024 NOTE: Dimensions in [ ] are millimeters. 7 30 PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES (cont) UNIT SIZES 028,034 NOTE: Dimensions in [ ] are millimeters. 8 31 Dimensions (cont) ECONOMIZER ACCESSORY UNIT SIZES 007-012 UNIT SIZES 014-024 UNIT SIZES 028,034 NOTES: 1. For horizontal unit applications, economizer can be attached to end of unit opposite duct connections. 2. Dimensions in [ ] are millimeters. 39 32 ELECTRIC HEAT ACCESSORY UNIT SIZES 007-012 UNIT SIZES 014-034 UNIT SIZE 014-024 028,034 A 1�-31⁄4� [387.4] 1�-33⁄8� [390.5] NOTE: Dimensions in [ B 4�-63⁄8� [1381.1] 5�-47⁄16� [1636.8] C 25⁄16� [58.7] 21⁄16� [26.9] D 2�-11⁄4� [641.4] 2�-63⁄16� [766.8] E 105⁄8� [269.9] 1�-1⁄4� [311.2] ] are millimeters. 40 33 F 1�-4� [406.4] 1�-7� [482.6] G 1�-45⁄16� [414.3] 1�-45⁄16� [414.0] H 1�-63⁄4� [476.3] 1�-10� [558.8] J 1�-7⁄8� [327.0] 1�-47⁄16� [417.1] FAN PERFORMANCE DATA — 0.0-1.2 in. wg ESP — 50 HZ, ENGLISH UNIT AIRFLOW (Cfm) 40RM 007 1,800 2,100 2,400 2,700 3,000 40RM 008 2,250 2,600 3,000 3,400 3,750 Rpm 320 373 427 480 533 359 415 478 542 598 0.0 0.2 Bhp EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp Rpm 1.0 Rpm 0.32 0.45 0.62 0.82 1.03 472 516 569 624 673 0.44 0.57 0.75 0.95 1.17 560 599 645 695 740 0.55 0.68 0.86 1.08 1.29 634 669 712 758 800 0.65 0.79 0.98 1.20 1.42 700 732 773 815 855 0.75 0.90 1.09 1.31 1.60 759 790 828 869 906 0.86 1.01 1.20 1.43 1.66 814 843 879 918 954 0.96 1.11 1.32 1.55 1.78 0.22 0.31 0.42 0.54 0.69 442 483 526 570 616 0.32 0.42 0.53 0.67 0.82 534 569 606 646 687 0.42 0.53 0.64 0.78 0.94 611 642 676 712 750 0.52 0.63 0.75 0.89 1.05 678 708 739 773 808 0.61 0.73 0.86 1.00 1.16 739 767 796 828 862 Bhp 0.70 0.82 0.96 1.11 1.28 Rpm 1.2 Bhp 795 821 849 880 912 Bhp 0.80 0.92 1.06 1.21 1.39 40RM 012 3,000 3,500 4,000 4,500 5,000 444 518 592 666 740 0.58 0.82 1.11 1.44 1.83 541 604 669 735 803 0.71 0.95 1.25 1.59 1.98 621 677 736 797 861 0.83 1.08 1.38 1.72 2.12 691 742 797 854 914 0.94 1.20 1.51 1.86 2.26 753 801 853 907 964 1.05 1.32 1.63 1.99 2.39 809 855 904 956 1010 1.17 1.44 1.75 2.12 2.53 862 906 953 1003 1055 1.28 1.56 1.88 2.24 2.66 40RM 014 3,750 4,300 5,000 5,700 6,250 0.37 0.53 0.81 1.17 1.51 475 517 573 631 678 0.58 0.78 1.08 1.47 1.83 566 601 650 702 744 581 629 675 730 779 0.80 1.02 1.35 1.76 2.15 1.00 1.35 1.73 2.26 2.81 645 676 719 766 805 1.02 1.26 1.62 2.06 2.47 715 743 782 826 862 1.24 1.50 1.89 2.36 2.79 779 805 841 881 915 1.47 1.74 2.16 2.66 3.11 839 862 896 934 966 1.69 1.99 2.44 2.96 3.43 40RM 016 4,500 5,300 6,000 6,800 7,500 363 416 484 552 605 40RM 024 6,000 7,000 8,000 9,000 10,000 503 586 670 754 838 1.07 1.64 2.37 3.28 4.39 587 660 735 812 891 1.37 1.98 2.74 3.69 4.83 661 726 795 867 941 1.67 2.31 3.12 4.09 5.27 727 787 851 918 988 1.97 2.65 3.49 4.50 5.70 789 844 904 967 1034 2.28 2.99 3.86 4.90 6.14 846 898 954 1014 1077 2.59 3.33 4.23 5.31 6.85 900 948 1001 1059 1120 2.90 3.67 4.61 5.72 7.02 471 550 628 707 785 1.78 2.72 3.93 5.44 7.27 539 608 679 752 826 2.17 3.15 4.40 5.94 7.81 604 665 730 797 867 2.63 3.64 4.92 6.49 8.39 667 720 779 841 907 3.17 4.18 5.48 7.08 9.01 728 774 827 885 947 3.78 4.79 6.09 7.71 9.66 788 827 874 928 986 4.46 5.45 6.76 8.38 10.35 845 878 921 970 1024 40RM 028 40RM 034 7,500 8,750 10,000 11,250 12,500 9,000 10,500 12,000 13,500 15,000 391 460 521 590 651 412 481 549 618 687 0.51 0.80 1.13 1.60 2.10 1.15 1.76 2.55 3.52 4.71 495 551 602 663 718 492 550 610 672 735 0.75 1.08 1.43 1.93 2.45 1.53 2.17 2.99 4.00 5.22 568 616 669 725 783 2.00 2.66 3.50 4.53 5.78 See Legend and Notes on page 47. 4 34 657 700 741 791 837 640 680 726 777 830 1.25 1.63 2.04 2.59 3.16 2.56 3.22 4.07 5.12 6.38 725 764 801 847 890 710 742 782 827 876 1.50 1.91 2.34 2.92 3.52 3.22 3.86 4.70 5.76 7.04 787 823 858 901 941 776 802 836 876 922 1.76 2.20 2.65 3.26 3.88 3.98 4.58 5.40 6.45 7.74 845 878 911 951 990 840 860 889 925 966 2.02 2.48 2.96 3.60 4.24 4.83 5.38 6.17 7.21 8.49 5.22 6.18 7.47 9.10 11.07 Performance data (cont) FAN PERFORMANCE DATA — 1.4-2.4 in. wg ESP — 50 Hz, ENGLISH UNIT AIRFLOW (Cfm) 40RM 007 1,800 2,100 2,400 2,700 3,000 Rpm 847 872 899 928 959 1.4 Bhp Rpm 0.89 1.02 1.16 1.32 1.49 896 920 946 974 1004 1.6 EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 2.2 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 0.98 1.11 1.26 1.42 1.60 942 965 990 1018 1046 1.07 1.21 1.36 1.52 1.71 986 1008 1033 1059 1087 1.16 1.30 1.46 1.63 1.81 1027 1050 1073 1099 1126 1.25 1.40 1.55 1.73 1.92 Rpm — — — — — 2.4 Bhp — — — — — 2,250 2,600 3,000 3,400 3,750 865 893 928 965 1000 40RM 012 3,000 3,500 4,000 4,500 5,000 911 953 999 1047 1097 1.39 1.67 2.00 2.37 2.79 958 998 1042 1089 1138 1.50 1.79 2.12 2.50 2.92 1002 1041 1084 1129 1177 1.61 1.90 2.24 2.62 3.05 1044 1082 1124 1168 — 1.72 2.02 2.36 2.74 — 1084 1122 1162 — — 1.83 2.13 2.48 — — 1123 1159 1199 — — 1.94 2.25 2.60 — — 40RM 014 3,750 4,300 5,000 5,700 6,250 899 930 961 999 1036 1.91 2.23 2.71 3.25 3.75 2.29 2.78 3.28 3.94 4.60 947 967 997 1031 1060 2.14 2.48 2.98 3.55 4.07 996 1016 1044 1076 1104 2.37 2.73 3.26 3.86 4.39 2.84 3.38 3.92 4.63 5.34 1044 1062 1089 1120 1147 1046 1072 1098 1132 1164 2.60 2.98 3.53 4.16 4.71 3.12 3.68 4.24 4.98 5.71 1089 1107 1133 1162 1188 1091 1116 1141 1173 — 2.83 3.24 3.81 4.46 5.03 3.41 3.99 4.57 5.33 — — — — — — 1133 1157 1181 — — — — — — — 40RM 016 4,500 5,300 6,000 6,800 7,500 894 916 948 984 1014 3.70 4.30 4.91 — — 40RM 024 6,000 7,000 8,000 9,000 10,000 950 996 1047 1102 1160 3.21 4.02 4.99 6.13 7.46 999 1042 1091 1143 1200 3.53 4.37 5.37 6.54 7.91 1045 1086 1133 1183 — 3.85 4.72 5.75 6.96 — 1089 1129 1173 — — 4.17 5.07 6.13 — — 1131 1169 — — — 4.50 5.43 — — — 1172 — — — — 4.83 — — — — 901 928 966 1011 1062 6.07 6.98 8.24 9.86 11.84 955 978 1011 1052 6.98 7.84 9.07 10.67 1008 1026 1055 1092 7.98 8.76 9.95 11.52 1060 1073 1098 — 9.05 9.74 10.88 — — — — — — — — — — — — — — — — — — — — — — — 40RM 008 40RM 028 40RM 034 7,500 8,750 10,000 11,250 12,500 9,000 10,500 12,000 13,500 15,000 903 917 941 972 1010 1.06 1.22 1.43 1.66 1.90 5.79 6.26 7.01 8.02 9.29 913 940 973 1010 1043 951 980 1009 1045 1080 963 972 991 1019 1053 1.16 1.33 1.54 1.78 2.02 2.56 3.08 3.60 4.28 4.97 6.83 7.22 7.91 8.89 10.15 958 984 1017 1052 1084 999 1027 1055 1089 1123 1021 1025 1040 1064 1095 1.27 1.43 1.65 1.89 2.13 7.98 8.26 8.89 9.83 11.05 1001 1027 1058 1092 1124 1078 1078 1089 — — 1.37 1.54 1.76 2.00 2.25 9.21 9.38 9.93 — — 1042 1067 1098 1131 1162 — — — — — — 1.47 1.65 1.87 2.12 2.37 — — — — — — — — — — — — — — — — — — — — — — — — — — — — See Legend and Notes on page 47. 5 35 Bhp ESP - FACTOR Y-SUPPLIED FILTER PRESSURE DROP - ENGLISH LEGEND Brake Horsepower Input to Fan External Static Pressure 40RM 007 AIRFLOW (Cfm) 1,800 2,400 3,000 PRESSURE DROP (in. wg) 0.05 0.08 0.11 40RM 008 2,250 3,000 3,750 0.07 0.11 0.15 40RM 012 3,000 4,000 5,000 0.11 0.17 0.23 40RM 014 3,750 5,000 6,250 0.06 0.10 0.13 40RM 016 4,500 6,000 7,500 0.08 0.12 0.17 6,000 8,000 10,000 7,500 10,000 12,500 9,000 12,000 15,000 0.12 0.19 0.26 0.15 0.22 0.30 0.19 0.29 0.40 UNIT Bold indicates field supplied drive is required. Plain type indicates standard motor and standard drive. Underline indicates a different motor and drive combination other than the standard motor and standard drive combination is required. Refer to fan motor and drive tables, pages 57-59, to complete selection. NOTES: 1. Maximum allowable fan speed is 1100 rpm for unit sizes 028 and 034; 1200 rpm for all other sizes. 2. Fan performance is based on deductions for wet coil, clean 1-in. filters, and unit casing. See table at right for factory-supplied filter pressure drop. 3. For 50 Hz units, the medium- static drive and standard motor combination is not available for 016-028 sizes. Use alternate motor if medium-static drive is required for these sizes. 40RM 024 40RM 028 40RM 034 ACCESSORY PLENUM AIR THROW DATA — ENGLISH (Ft) UNIT 40RM 007 NOTE: Throw distances shown are for 75 fpm terminal velocity. Use the following multipliers to determine throw values for other terminal velocities. TERMINAL VELOCITY (Fpm) 50 100 150 6 THROW FACTOR X X X 1.50 0.75 0.50 36 AIRFLOW (Cfm) VANE DEFLECTION Straight 211⁄2° 45° 2,400 39 33 24 40RM 008 3,000 45 38 28 40RM 012 4,000 55 46 33 40RM 014 5,000 45 38 28 40RM 016 6,000 50 43 31 40RM 024 8,000 60 51 37 40RM 028 10,000 76 65 47 40RM 034 12,000 85 72 52 ACCESSORY PRESSURE DROP — ENGLISH (in. wg) HEATING COILS Steam 0.10 0.16 0.23 AIRFLOW (Cfm) RETURN AIR GRILLE 40RM 007 1,800 2,400 3,000 DISCHARGE PLENUM 0.01 0.01 0.02 Hot Water 0.10 0.16 0.23 40RM 008 2,250 3,000 3,750 0.09 0.14 0.21 0.01 0.02 0.03 0.15 0.23 0.35 0.15 0.23 0.35 0.06 0.10 0.15 0.06 0.09 0.15 40RM 012 3,000 4,000 5,000 0.14 0.22 0.32 0.02 0.04 0.06 0.23 0.37 0.53 0.23 0.37 0.53 0.10 0.17 0.26 0.09 0.17 0.28 40RM 014 3,750 5,000 6,250 0.07 0.12 0.17 0.01 0.02 0.02 0.11 0.17 0.25 0.11 0.17 0.25 0.04 0.07 0.11 0.05 0.07 0.11 40RM 016 4,500 6,000 7,500 0.10 0.16 0.23 0.01 0.02 0.03 0.15 0.23 0.33 0.15 0.23 0.33 0.06 0.10 0.15 0.06 0.09 0.15 6,000 8,000 10,000 7,500 10,000 12,500 9,000 12,000 15,000 0.16 0.26 0.37 0.15 0.24 0.34 0.20 0.32 0.46 0.02 0.04 0.06 0.02 0.03 0.05 0.03 0.05 0.07 0.23 0.37 0.53 0.28 0.44 0.63 0.37 0.59 0.85 0.23 0.37 0.53 0.28 0.44 0.63 0.37 0.59 0.85 0.10 0.17 0.26 0.09 0.16 0.24 0.13 0.22 0.34 0.09 0.17 0.28 0.06 0.09 0.14 0.08 0.14 0.21 UNIT 40RM 024 40RM 028 40RM 034 0.06 0.10 0.14 Electric 0.04 0.06 0.10 ECONOMIZER 0.05 0.07 0.09 7 37 Electrical data STANDARD MOTORS UNIT V*-PH-Hz VOLTAGE LIMITS 40RM 007 40RM 008 230-3-50 400-3-50 230-3-50 400-3-50 40RM 012 40RM 014 40RM 016 FAN MOTOR Hp (kW) FLA 207-253 360-440 207-253 360-440 2.4 2.4 2.4 2.4 (1.79) (1.79) (1.79) (1.79) 5.2 2.6 5.2 2.6 230-3-50 400-3-50 207-253 360-440 2.9 (2.16) 2.9 (2.16) 230-3-50 400-3-50 207-253 360-440 2.9 (2.16) 2.9 (2.16) 230-3-50 400-3-50 207-253 360-440 40RM 024 230-3-50 400-3-50 40RM 028 230-3-50 400-3-50 207-253 360-440 40RM 034 230-3-50 400-3-50 207-253 360-440 2.9 (2.16) 2.9 (2.16) 207-253 360-440 POWER SUPPLY Minimum Circuit MOCP Amps 6.5 3.3 6.5 3.3 15 15 15 15 7.5 3.4 9.4 4.3 15 15 7.5 3.4 9.4 4.3 15 15 7.5 3.4 9.4 4.3 15 15 5.0 (3.73) 5.0 (3.73) 15.2 7.6 19.0 9.5 30 15 7.5 (5.59) 7.5 (5.59) 10.0 (7.46) 10.0 (7.46) 22.8 11.4 28.5 14.3 50 25 32.2 16.1 40.3 20.1 70 30 . ALTERNATE MOTORS FAN MOTOR UNIT V*-PH-Hz VOLTAGE LIMITS Hp (kW) FLA 40RM 007 230-3-50 400-3-50 207-253 360-440 2.4 (1.79) 2.4 (1.79) 5.2 2.6 230-3-50 400-3-50 207-253 360-440 5.0 (3.73) 5.0 (3.73) 5.0 (3.73) 5.0 (3.73) 40RM 008 40RM 012 40RM 014 40RM 016 40RM 024 40RM 028 230-3-50 400-3-50 230-3-50 400-3-50 230-3-50 400-3-50 230-3-50 400-3-50 230-3-50 400-3-50 207-253 360-440 207-253 360-440 207-253 360-440 207-253 360-440 207-253 360-440 2.9 (2.16) 2.9 (2.16) 5.0 (3.73) 5.0 (3.73) 7.5 (5.59) 7.5 (5.59) 10.0 (7.46) 10.0 (7.46) 6.5 3.3 15 15 15.2 7.6 19.0 9.5 30 15 15.2 7.6 19.0 9.5 7.5 3.4 9.4 4.3 15.2 7.6 19.0 9.5 22.8 11.4 28.5 14.3 32.2 16.1 40.3 20.1 15 15 30 15 30 15 50 25 60 30 Determine maximum deviation from average voltage. (AB) 397 − 393 = 4 v (BC) 403 − 397 = 6 v (AC) 397 − 396 = 1 v Maximum deviation is 6 v. LEGEND FLA — Full Load Amps MOCP — Maximum Overcurrent Protection *Motors are designed for satisfactory operation within 10% of nominal voltages shown. Voltages should not exceed the limits shown in the Voltage Limits column. NOTES: 1. Minimum circuit amps (MCA) and MOCP values are calculated in accordance with NEC (National Electrical Code) (U.S.A. standard), Article 440. 2. Motor FLA values are established in accordance with UL (Underwriters’ Labo ratories) Standard 1995 (U.S.A. standard). 3. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage Imbalance max voltage deviation from average voltage = 100 x average voltage EXAMPLE: Supply voltage is 400-3-50. AB = 393 v BC = 403 v AC = 396 v 393 + 403 + 396 Average Voltage = 3 1192 = 3 = 397 8 POWER SUPPLY Minimum Circuit MOCP Amps Determine percent voltage imbalance. 6 397 % Voltage Imbalance = 100 x = 1.5% This amount of phase imbalance is satisfactory because it is below the maxi mum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, con tact your local electric utility company immediately. 38 Electrical data (cont) ELECTRIC HEATER DATA HEATER PART NO. UNIT V-PH-Hz FAN MOTOR Hp kW FLA Nominal Capacity (kW) ELECTRIC HEATER(S) Actual Capacity (kW) Stage 1 Stage 2 Total FLA MCA* MOCP* CAELHEAT001A00 240-3-50 2.4 2.9 5.0 1.79 2.16 3.73 5.2 7.5 15.2 5 5 5 5.0 5.0 5.0 — — — 5.0 5.0 5.0 12.0 12.0 12.0 21.5 24.4 34.0 25 25 40 CAELHEAT002A00 400-3-50 2.4 2.9 5.0 1.79 2.16 3.73 2.6 3.4 7.6 5 5 5 3.5 3.5 3.5 — — — 3.5 3.5 3.5 5.00 5.00 5.00 9.5 10.5 15.8 15 15 20 240-3-50 2.4 2.9 5.0 1.79 2.16 3.73 5.2 7.5 15.2 10 10 10 10.0 10.0 10.0 — — — 10.0 10.0 10.0 24.1 24.1 24.1 36.6 39.4 49.1 40 40 50 CAELHEAT004A00 40RM007-012 CAELHEAT005A00 400-3-50 2.4 2.9 5.0 CAELHEAT007A00 240-3-50 2.4 2.9 5.0 1.79 2.16 3.73 5.2 7.5 15.2 15 15 15 15.0 15.0 15.0 — — — 15.0 15.0 15.0 36.1 36.1 36.1 51.6 54.5 64.1 60 60 70 CAELHEAT008A00 400-3-50 2.4 2.9 5.0 1.79 2.16 3.73 2.6 3.4 7.6 15 15 15 10.4 10.4 10.4 — — — 10.4 10.4 10.4 15.0 15.0 15.0 22.0 23.0 28.3 25 25 30 CAELHEAT010A00 240-3-50 CAELHEAT011A00 25.1 25.1 25.1 34.6 35.6 40.8 CAELHEAT013A00 40RM008,012 60.1 60.1 60.1 400-3-50 2.4 2.9 5.0 25.0 25.0 25.0 240-3-50 2.4 2.9 5.0 1.79 2.16 3.73 5.2 7.5 15.2 35 35 35 20.0 20.0 20.0 15.0 15.0 15.0 35.0 35.0 35.0 2.9 5.0 7.5 2.9 5.0 7.5 2.9 5.0 7.5 2.9 5.0 7.5 2.9 5.0 7.5 2.9 5.0 7.5 2.9 5.0 7.5 2.16 3.73 5.59 2.16 3.73 5.59 2.16 3.73 5.59 2.16 3.73 5.59 2.16 3.73 5.59 2.16 3.73 5.59 2.16 3.73 5.59 7.5 15.2 22.8 3.4 7.6 11.4 7.5 15.2 22.8 3.4 7.6 11.4 7.5 15.2 22.8 3.4 7.6 11.4 7.5 15.2 22.8 10 10 10 10 10 10 20 20 20 20 20 20 30 30 30 30 30 30 50 50 50 10.0 10.0 10.0 6.9 6.9 6.9 20.0 20.0 20.0 13.9 13.9 13.9 20.0 20.0 20.0 13.9 13.9 13.9 30.0 30.0 30.0 — — — — — — — — — — — — 10.0 10.0 10.0 6.9 7.9 7.9 20.0 20.0 20.0 7.5 10.0 7.5 10.0 7.5 10.0 7.5 10.0 7.5 10.0 7.5 10.0 7.5 10.0 7.5 10.0 5.59 7.46 5.59 7.46 5.59 7.46 5.59 7.46 5.59 7.46 5.59 7.46 5.59 7.46 5.59 7.46 22.8 32.2 11.4 16.1 22.8 32.2 11.4 16.1 22.8 32.2 11.4 16.1 22.8 32.2 11.4 16.1 20 20 20 20 40 40 40 40 50 50 50 50 70 70 70 70 20.0 20.0 13.9 13.9 20.0 20.0 13.9 13.9 30.0 30.0 20.8 20.8 40.0 40.0 27.8 27.8 — — — — 20.0 20.0 13.9 13.9 20.0 20.0 13.9 13.9 30.0 30.0 20.8 20.8 240-3-50 CAELHEAT020A00 400-3-50 CAELHEAT022A00 240-3-50 CAELHEAT023A00 400-3-50 240-3-50 CAELHEAT026A00 400-3-50 CAELHEAT028A00 240-3-50 CAELHEAT029A00 400-3-50 CAELHEAT031A00 240-3-50 CAELHEAT034A00 10.0 10.0 10.0 10.0 10.0 10.0 400-3-50 40RM028,034 6.9 6.9 6.9 15.0 15.0 15.0 CAELHEAT017A00 CAELHEAT032A00 — — — 25 25 25 240-3-50 40RM016,024 6.9 6.9 6.9 5.2 7.5 15.2 CAELHEAT016A00 CAELHEAT025A00 10 10 10 1.79 2.16 3.73 400-3-50 40RM014-024 2.6 3.4 7.6 2.4 2.9 5.0 CAELHEAT014A00 CAELHEAT019A00 1.79 2.16 3.73 400-3-50 240-3-50 CAELHEAT035A00 400-3-50 CAELHEAT037A00 240-3-50 CAELHEAT038A00 400-3-50 2.4 2.9 5.0 2.9 5.0 7.5 1.79 2.16 3.73 1.79 2.16 3.73 2.16 3.73 5.59 2.6 3.4 7.6 25 25 25 2.6 3.4 7.6 35 35 35 3.4 7.6 11.4 50 50 50 10.4 10.4 10.4 13.9 13.9 13.9 20.8 20.8 20.8 6.9 6.9 6.9 10.4 10.4 10.4 13.9 13.9 13.9 15.8 16.8 22.0 20 20 25 81.7 84.6 94.2 90 90 100 84.2 84.2 84.2 111.7 114.6 124.2 125 125 125 10.0 10.0 10.0 6.9 6.9 6.9 20.0 20.0 20.0 13.9 13.9 13.9 30.0 30.0 30.0 20.8 20.8 20.8 50.0 50.0 50.0 24.1 24.1 24.1 10.0 10.0 10.0 48.1 48.1 48.1 20.0 20.0 20.0 72.2 72.2 72.2 30.1 30.1 30.1 120.3 120.3 120.3 39.4 49.1 58.6 16.8 22.0 26.8 69.5 79.1 86.4 29.3 45.1 49.2 99.6 109.2 118.7 41.8 47.1 51.8 159.7 169.4 178.9 40 50 70 20 25 35 70 80 90 30 50 50 100 110 125 50 50 60 175 175 200 20.0 20.0 13.9 13.9 40.0 40.0 27.8 27.8 50.0 50.0 34.7 34.7 70.0 70.0 48.6 48.6 48.1 48.1 20.0 20.0 96.2 96.2 40.1 40.1 120.3 120.3 50.1 50.1 168.4 168.4 70.2 70.2 88.6 100.4 39.3 45.2 148.8 160.5 64.4 70.2 178.9 190.6 76.9 82.8 196.9 208.6 84.4 90.3 90 110 40 50 150 175 70 80 200 200 80 90 200 225 90 100 17.4 17.4 17.4 24.3 24.3 24.3 34.7 34.7 34.7 35.1 35.1 35.1 50.1 50.1 50.1 47.1 48.1 53.4 66.9 72.1 76.9 25 40 50 50 50 60 70 80 80 49 39 FLA Hp MCA MOCP — — — — 2. The following equation converts kW of heat energy to Btuh: kW x 3,412 = Btuh. 3. Heater contactor coils are 24 v and require 8 va holding current. 4. Electric heaters are tested and ETL approved at maximum total external static pressure of 1.9 in. wg. 5. MCA and MOCP values apply to both standard and alternate factory-supplied motors. LEGEND Full Load Amps Horsepower Minimum Circuit Amps Maximum Overcurrent Protection (Amps) *Values shown are for single-point connection of electric heat accessory and air handler. †Single-phase motors. All other motors are 3-phase. NOTES: 1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v ca pacity (kW) by the factor shown in the table below for the unit voltage. HEATER ACTUAL HEATER VOLTAGE RATING VOLTAGE 200 208 230 240 400 440 460 480 550 240 0.694 0.751 0.918 1 — — — — — 480 — — — — 0.694 0.84 0.918 1 — 575 — — — — — — — — 0.915 575 600 — — — — 1 1.089 50 40 Typical piping and wiring VERTICAL INST ALLA TION - 40RM (TYPICAL) NEC TXV - LEGEND National Electrical Code Thermostatic Expansion Valve Piping *Field supplied. ²Double riser may be required. Consult condensing unit product data catalog for details. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a specific installation. 4. Liquid line solenoid valve (solenoid drop control) is recommended to prevent refrigerant migration to the compressor. 5. Internal factory-supplied TXVs not shown. 51 41 HORIZONT AL INST ALLA TION - NEC TXV - LEGEND National Electrical Code Thermostatic Expansion Valve 40RM (TYPICAL) 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a spe cific installation. 4. Liquid line solenoid valve (solenoid drop control) is recommended to prevent refrigerant migration to the compressor. 5. Internal factory-supplied TXVs not shown. *Accessory item. ²Field supplied. NOTES: 1. All piping must follow standard refrigerant piping techniqes. Refer to Carrier System Design Manual for details. 52 42 Typical piping and wiring (cont) WIRE ROUTING, BASE UNIT - 40RM, WIRE ROUTING, UNIT WITH ELECTRIC HEAT - NEC - 40RM, National Electrical Code 3 43 CONTROL WIRING SCHEMA TIC - TYPICAL EQUIP GND HC HTR IFC IFM TB - LEGEND Equipment Ground Heater Contactor Heater Element Indoor Fan Contactor Indoor Fan Motor Terminal Block Factory Wiring Field Wiring Application data The air handler fan must always be operating when the condensingunit is operating. Ductwork should be sized according to unit size, not building load. For larger units with two fans, a split duct transition is recommendedat the fan outlets, but a plenum can be usedwith slight reduction in external static pressure capability. For variable air volume (VAV) systems with supply-to return air recycling, usethe equipment room as a return air plenum. Operating limits Maximum fan speed . . . . . . . . . . . . . . . . 1200 rpm (20 r/s) 40RM007-024 40RM028,034 . . . . . . . . . . . . . . . . 1100 rpm (18.3 r/s) General Select equipment to match or to be slightly lessthan peak load. This providesbetter humidity control, lessunit cycling, and lesspart-load operation. Equipment should be selected to perform at no lessthan 300 cfm/ton (40 L/s per kW). FACTOR Y-INST ALLED NOZZLE AND DISTRIBUTOR DATA UNIT 40RM007 40RM008 40RM012 40RM014 40RM016 40RM024 40RM028 40RM034 TXV Qty...Part No.* 1...XVE-5 1...SVE-8 2...XVE-4 2...XVE-5 2...XVE-8 2...XVE-10 2...SVE-15 2...SVE-15 DISTRIBUTOR Qty...Part No.* 1...1116 1...1126 2...1115 2...1115 2...1116 2...1116 2...1126 2...1126 *Sporlan Valve Co. part numbers shown. 4 44 FEEDER TUBES PER DISTRIBUTOR Qty...Size (in.) 12...1/4 15...1/4 9...1/4 9...1/4 12...1/4 13...1/4 15...1/4 18...1/4 NOZZLE Qty...Part No. 1...E5 1...C6 2...E4 2...E5 2...E6 2...E8 2...C10 2...C12 FAN MOTOR Application data (cont) DATA -ENGLISH STANDARD MOTOR (230-3-50 and 400-3-50) HIGH-ST ATIC DRIVE DATA, 5 0 Hz 40RM 007 UNIT 40RM 008 40RM 007 1425 2.4 56Y 86.4 5/8 111.8 40RM 012 40RM 008 1425 2.9 56Y 86.4 111.87/8 SI 40RM 40RM 40RM 024 016 014 40RM 40RM 40RM 40RM 012 1425 014 1425 016 1425024 2.9 2.9 5.0 101.656Y 86.4 56Y 101.6 184T 101.6 11/8127.0 127.0 7/8 111.8 7/8 127.0 40RM 028 40RM 028 1425 7.5 S213T 109.2 13/8 134.6 UNIT Speed (rpm) 1425 Hp 2.4 MOTOR DRIVE Frame (NEMA) 56Y Motor Pulley Pitch Diameter 5/8 Shaft Dia (in.) (mm) Pulley Factory Setting 2.5 2.5 3.0 2.5 3.0 3.0 3.0 Full Turns Open FAN DRIVE ALTERNATE MOTOR (230-3-50 and 400-3-50) Pulley Pitch Dia (mm) 152 140 140 152 178 163 203 Pulley Bore (mm) 25.4 40RM25.4 25.4 36.5 36.540RM 36.5 40RM49.2 40RM 40RM 40RM UNIT 014 024 2-B 007 008 1-A 012 Belt No. Section 1-A 1-A 2-A 2-A 016 2-A Belt Pitch (mm) 947 947 922 922 998 871 935 (rpm) 1425 1425 1425 1425 1425 1425 FANSpeed SPEEDS (r/s) Hp 2.4 5.0 5.0 7.5 14.3 Factory Setting 15.4 2.9 16.8 19.4 15.4 15.3 5.0 16.7 Frame (NEMA) 56Y S184T S184T S184T 14.9 S213T12.8 13.5 56Y 14.7 17.3 13.5 13.6 Range 7/8 7/8 7/8 17.4 19.0 20.0* 17.4 17.0 11/8 18.6 Shaft Dia (in.) 11/8 13/8 15.7 Max Allowable Speed (r/s) 20.0 20.0 20.0 20.0 20.0 20.0 18.3 NEMA - National Electrical Manufacturers Association (U.S.A.) Change per 1/2 Turn of Moveable Motor Pulley 0.395 0.432 0.360 0.395 0.283 0.308 0.247 Flange MAX FULL TURNS FROM 5 5 6 5 6 6 6 CLOSED POSITION SHAFTS CENTER DISTANCE 265-313 265-313 234-279 232-279 232-279 207-255 169-240 (mm) 40RM 034 40RM 034 1425 10.0 S215T 109.2 13/8 134.6 3.0 218 49.2 40RM 028 2-B 960 1425 10.0 13.3 S215T 11.9 3/8 114.6 18.3 0.230 6 169-240 *It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s. STANDARD DRIVE DATA, 5 0 Hz UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) ENGLISH 5 40RM 007 40RM 008 40RM 012 40RM 014 40RM 016 40RM 024 40RM 028 40RM 034 2.4-3.4 2.8-3.8 3.4-4.4 3.4-4.4 3.4-4.4 4.3-5.3 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 8.0 1 1-A 39.3 8.0 1 1-A 39.3 8.0 1 1-A 40.3 9.0 1 7/16 1-A 42.3 9.0 1 7/16 1-A 42.3 8.6 1 7/16 1-B 41.8 11.0 1 15/16 2-B 43.8 11.0 1 15/16 2-B 43.8 517 428-606 1200 588 499-677 1200 695 606-784 1200 618 538-697 1200 618 538-697 1200 795 713-878 1200 622 557-687 1100 622 557-687 1100 17.8 17.8 17.8 15.9 15.9 13.8 10.8 10.8 5 5 5 5 5 6 6 6 10.44 12.32 10.44 12.32 10.44 12.32 10.44 12.32 10.44 12.32 9.12 10.99 6.67 9.43 6.67 9.43 7 45 MEDIUM-ST ATIC DRIVE DATA, 5 0 Hz UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 008 40RM 012 40RM 014 40RM 016 40RM 024 40RM 028 40RM 034 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.7-4.7 4.0-5.0 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 3.0 2.5 3.0 3.0 8.0 1 1-A 40.3 7.0 1 1-A 41.3 6.0 1 1-A 37.3 7.5 1 7/16 1-A 39.3 7.9 1 7/16 1-B 39.8 7.0 1 7/16 2-A 36.8 9.4 1 15/16 2-B 39.8 9.4 1 15/16 2-B 39.8 695 606-784 1200 794 692-896 1200 926 808-1045 1200 741 646-836 1200 756 667-848 1200 916 814-1018 1200 728 652-803 1100 728 652-803 1100 17.8 20.4 23.7 19.0 15.1 20.4 12.6 12.6 5 5 5 5 6 5 6 6 10.44 12.32 10.44 12.32 10.44 12.32 10.44 12.32 9.16 10.99 9.16 10.99 6.67 9.43 6.67 9.43 HIGH-ST ATIC DRIVE DATA, 5 0 Hz UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) ENGLISH 40RM 007 40RM 008 40RM 012 40RM 014 40RM 016 40RM 024 40RM 028 40RM 034 3.4-4.4 3.4-4.4 4.0-5.0 3.4-4.4 4.0-5.0 4.0-5.0 4.3-5.3 4.3-5.3 2.5 2.5 3.0 2.5 3.0 3.0 3.0 3.0 6.0 1 1-A 37.3 5.5 1 1-A 37.3 5.5 1 1-A 36.3 6.0 1 7/16 2-A 36.3 7.0 1 7/16 2-A 39.3 6.4 1 7/16 2-A 34.3 8.0 1 15/16 2-B 36.8 8.6 1 15/16 2-B 37.8 926 808 1045 1200 1010 881 1140 1200 1166 1036 1200* 1200 926 808 1045 1200 916 814 1018 1200 1002 891 1113 1200 855 766 944 1100 795 713 878 1100 23.7 25.9 21.6 23.7 17.0 18.5 14.8 13.8 5 5 6 5 6 6 6 6 10.44 12.32 10.44 12.32 916 10.99 9.16 10.99 9.16 10.99 8.16 10.02 6.67 9.43 6.67 9.43 *It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 1200 rpm. 8 ENGLISH 46 Guide Specifications 38ARZ007-012 Commercial Air-Cooled Condensing Units HVAC Guide Specifications Size Range: 6 to 10 Tons, Nominal Carrier Model Numbers: 38ARZ, Sizes 007-012 Part 1 — General .0 SYSTEM DESCRIPTION Outdoor-mounted, air-cooled condensing unit suitable for on-the-ground or rooftop installation. Unit shall consist of a reciprocating or scroll airconditioning compressor assembly, an air-cooled coil, propeller- type condenser fans, and a control box. Unit shall discharge supply air upward as shown on contract drawings. Unit shall be used in a refrigeration circuit matched with a packaged airhandling unit. .0 QUALITY ASSURANCE A. Unit shall be rated in accordance with ARI Standard 0-000. B. Unit construction shall comply with ANSI/ASHRAE safety code latest revision and comply with NEC. C. Unit shall be constructed in accordance with UL standard. D. Unit cabinet shall be capable of withstanding 00-hour salt spray exposure per ASTM B (scribed specimen). E. Air-cooled condenser coils for (ARZ) shall be leak tested at 00 psig, and pressure tested at psig. F. Unit shall be manufactured in a facility registered to ISO 00:000 manufacturing quality standard. .0 DELIVERY, STORAGE, AND HANDLING Unit shall be shipped as single package only, and shall be stored and handled according to unit manufacturer’s recommendations. .0 WARRANTY (FOR INCLUSION SPECIFYING ENGINEER.) BY Part 2 — Products .0 EQUIPMENT A. General: Factory-assembled, single piece, air-cooled condensing unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, compressor, holding charge (R-), and special features required prior to field start-up. B. Unit Cabinet: . Unit cabinet shall be constructed of galvanized steel, bonderized and coated with a prepainted baked enamel finish. . A heavy-gage roll-formed perimeter base rail with forklift slots and lifting holes shall be provided to facilitate rigging. C. Fans: . Condenser fans shall be direct driven, propeller type, discharging air vertically upward. . Fan blades shall be balanced. . Condenser fan discharge openings shall be equipped with PVC-coated steel wire safety guards. . Condenser fan and motor shaft shall be corrosion resistant. D. Compressor: . Compressor shall be of the hermetic scroll type . Compressor shall be mounted on rubber grommets. . Compressors shall include overload protection. . Compressors shall be equipped with a crankcase heater. . Compressor shall be equipped with internal high discharge temperature protection (ARZ00 and 0 only). E. Condenser Coil: . Condenser coil shall be air-cooled and circuited for integral subcooler. . Coil shall be constructed of aluminum fins (copper fins optional) mechanically bonded to internally grooved seamless copper tubes which are then cleaned, dehydrated, and sealed. F. Refrigeration Components: Refrigeration circuit components shall include liquid line service valve, suction line service valve, a full charge of compressor oil, and a holding charge of refrigerant. G. Controls and Safeties: . Minimum control functions shall include: a. Control wire terminal blocks. b. Compressor lockout on auto-reset safety until reset from thermostat. . Minimum safety devices which are equipped with automatic reset (after resetting first at thermostat), shall include: a. High discharge pressure cutout. b. Low pressure cutout. c. High discharge temperature cutout (ARZ00 only). H. Operating Characteristics: . The capacity of the condensing unit shall meet or exceed _____ Btuh at a suction temperature of 59 47 _____ F. The power consumption at full load shall not exceed _____ kW. . The combination of the condensing unit and the evaporator or fan coil unit shall have a total net cooling capacity of _____ Btuh or greater at conditions of _____ cfm entering-air temperature at the evaporator at _____ F wet bulb and _____ F dry bulb, and air entering the condensing unit at _____F. . The system shall have an EER of _____ Btuh/ Watt or greater at standard ARI conditions. I. Electrical Requirements: . Nominal unit electrical characteristics shall be _____ v, -ph, 50 Hz. The unit shall be capable of satisfactory operation within voltage limits of ____ v to _____ v. . Unit electrical power shall be single-point connection. . Unit control circuit shall contain a -v transformer for unit control. J. Special Features: . Low-Ambient Temperature Control: A low-ambient temperature control shall be available as a field-installed accessory. This lowambient control shall regulate speed of the condenser-fan motors in response to the saturated condensing temperature of the unit. The control shall maintain correct condensing pressure at outdoor temperatures down to –0 F. . Gage Panel Package: Gage panel package shall include a suction and discharge pressure gage. . Optional Condenser Coil Materials: a. Pre-Coated Aluminum-Fin Coils: Coils shall have a durable epoxy-phenolic coating to provide protection in mildly corrosive coastal environments. Coating shall be applied to the aluminum fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals. b. Copper-Fin Coils: Coils shall be constructed of copper-fins mechanically bonded to copper-tubes and copper tube sheets. A polymer strip shall prevent coil assembly from contacting sheet metal coil pan to minimize potential for galvanic corrosion between the coil and pan. All copper construction shall provide protection in moderate coastal environments. . Thermostat Controls: a. Programmable multi-stage thermostat shall have -day clock, holiday scheduling, large backlit display, remote sensor capability, and Title compliance. b. Commercial Electronic Thermostat shall have day timeclock, auto-changeover, multi-stage capability, and large LCD (liquid crystal display) temperature display. c. Carrier PremierLink™ Controller: This control will function with CCN (Carrier Comfort Network®) and ComfortVIEW™ software. It shall also be compatible with ComfortLink™ controllers. It shall be ASHRAE - compliant and Internet ready. It shall accept a CO sensor in the conditioned space and be Demand Control Ventilation (DCV) ready. The communication rate must be .K or faster. It shall include an integrated economizer controller. 60 48 Guide specifications— 38ARD014-028 Commercial Air-Cooled Condensing Units HVAC Guide Specifications Size Range: 121/2 to 20 Tons, Nominal Carrier Model Number: 38ARD, Sizes 014-024 Part 1 — General .0 SYSTEM DESCRIPTION Outdoor-mounted, air-cooled condensing unit suitable for on-the-ground or rooftop installation. Unit shall have independent refrigeration circuits. Unit shall consist of dual scroll compressors, an aircooled coil, propeller-type condenser fans, and a control box. Unit shall discharge supply air upward as shown on contract drawings. Unit shall be used in a refrigeration circuit matched with a packaged airhandling unit. .0 QUALITY ASSURANCE A. Unit shall be rated in accordance with ARI Standard 0-000, and shall be certified and listed in the latest ARI directory. B. Unit construction shall comply with ANSI/ASHRAE safety code, latest revision, and comply with NEC. C. Unit shall be constructed in accordance with UL standard and shall carry the UL and UL, Canada label. D. Unit cabinet shall be capable of withstanding 00-hour salt spray exposure per ASTM B (scribed specimen). E. Air-cooled condenser coils shall be leak tested at 0 psig, and pressure tested at 0 psig. F. Unit shall be manufactured in a facility registered to ISO 00:000 manufacturing quality standard. .0 DELIVERY, STORAGE, AND HANDLING Unit shall be shipped as single package only, and shall be stored and handled according to unit manufacturer’s recommendations. .0 WARRANTY (FOR INCLUSION BY SPECIFYING ENGINEER.) Part 2 — Products .0 EQUIPMENT A. General: Factory-assembled, single piece, air-cooled condensing unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, compressor, holding charge (R-), and special features required prior to field start-up. B. Unit Cabinet: Unit cabinet shall be constructed of G-0 galvanized steel, bonderized and coated with a prepainted baked enamel finish. C. Fans: . Condenser fans shall be direct driven, propellertype, discharging air vertically upward. . Fan blades shall be balanced. . Condenser fan discharge openings shall be equipped with PVC-coated steel wire safety guards. . Condenser fan and motor shaft shall be corrosion resistant. D. Compressor: . Compressors shall be of the hermetic scroll type. . Compressors shall be mounted on rubber grommets. . Compressors shall include overload protection. . Compressors shall be equipped with a crankcase heater. . Compressors shall be equipped with internal high discharge temperature protection (ARD0 and 0 only). E. Condenser Coil: . Condenser coil shall be air-cooled and circuited for integral subcooler. . Coil shall be constructed of aluminum fins (copper fins optional) mechanically bonded to internally grooved seamless copper tubes which are then cleaned, dehydrated, and sealed. F. Refrigeration Components: Refrigeration circuit components shall include high side pressure relief device, liquid line service valve, suction line service valve, a full charge of compressor oil, and a holding charge of refrigerant. G. Controls and Safeties: . Minimum control functions shall include: a. Power and control wire terminal blocks. b. Compressor lockout on auto-reset safety until reset from thermostat. c. Recycle time delay of five minutes to prevent compressor short cycling. . Minimum safety devices shall include: Automatic reset (after resetting first at thermostat): a. High discharge pressure cutout. b. Loss-of-charge cutout. c. Condenser fan motors to be protected against overload condition by internal overloads. Manual reset at the unit: Electrical overload protection through the use of define-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers. Circuit breakers shall open all three phases in the event of an overload in any one of the phases or a single phase condition. H. Operating Characteristics: . The capacity of the condensing unit shall meet or exceed _____ Btuh at a suction temperature of _____ F. The power consumption at full load shall not exceed _____ kW. 61 49 . The combination of the condensing unit and the evaporator or fan coil unit shall have a total net cooling capacity of _____ Btuh or greater at conditions of _____ cfm entering-air temperature at the evaporator at _____ F wet bulb and _____ F dry bulb, and air entering the condensing unit at _____ F. . The system shall have an EER of _____ Btuh/ Watt or greater at standard ARI conditions. I. Electrical Requirements: . Nominal unit electrical characteristics shall be _____ v, -ph, 50 Hz. The unit shall be capable of satisfactory operation within voltage limits of _____ v to _____ v. . Unit electrical power shall be single-point connection. . Unit control circuit shall contain a -v transformer for unit control. J. Special Features: . Low-Ambient Temperature Control: A low-ambient temperature control shall be available as a factory-installed option or as a fieldinstalled accessory. This low-ambient control shall regulate speed of the condenser-fan motors in response to the saturated condensing temperature of the unit. The control shall maintain correct condensing pressure at outdoor temperatures down to –0 F. . Gage Panel Package: Gage panel package shall include a suction and discharge pressure gage. . Optional Condenser Coil Materials: a. Pre-Coated Aluminum-Fin Coils: Coils shall have a durable epoxy-phenolic coating to provide protection in mildly corrosive coastal environments. Coating shall be applied to the aluminum fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals. b. Copper-Fin Coils: Coils shall be constructed of copper-fins mechanically bonded to copper-tubes and copper tube sheets. A polymer strip shall prevent coil assembly from contacting sheet metal coil pan to minimize potential for galvanic corrosion between the coil and pan. All copper construction shall provide protection in moderate coastal environments. . Thermostat Controls: a. Programmable multi-stage thermostat with -day clock, holiday scheduling, large backlit display, remote sensor capability, and Title compliance. b. Commercial Electronic Thermostat with -day timeclock, auto-changeover, multistage capability, and large LCD (liquid crystal display) temperature display. c. Carrier PremierLink™ Controller: This control will function with Carrier Comfort Network® (CCN) and ComfortVIEW™ software. It shall also be compatible with ComfortLink™ controllers. It shall be ASHRAE - compliant and Internet ready. It shall accept a CO sensor in the conditioned space and be Demand Control Ventilation (DCV) ready. The communication rate must be .K or faster. It shall include an integrated economizer controller. 62 50 Guide specifications 40RM A. Base Unit (Painted): 1. Cabinetshall be constructed of zinc coated steel and polyester powder painted to protect them from corrosion in the harsh Middle Eastern climate and also to increase the colour life in high ultra violet (UV) radiation regions. 2. Cabinet panels shall be fully insulated with 1/2 in. (12.7-mm) fire-retardant material. Commercial Packaged Air-Handling Unit HVAC Guide Specifications SizeRange: 2,400 to 12,000 CFM (1150 to 5650 L/s), Nominal Airflow 6 t o 3 0 Tons (21 to 105 kW), Nominal Cooling Carrier Model Numbers: 40RM (Direct-Expansion Coil) 3. Unit shall contain PVC condensate drain pans for both vertical and horizontal applications. Drain pans shallhave connectionson right and left sides of unit to facilitate field connection. Drain pans shall have the ability to be sloped toward the right or left side of the unit to prevent standing water from accumulatingin pans. 4. Unit shall have factory-supplied 1-in. (25.4 mm) washable-type filters installed upstream from the cooling coil. Filter access shall be from the front of the unit. B. Coils: Coils shall consist of 3 rows (40RM), of coppertubes with sine-wave aluminum fins bonded to the tubes by mechanical expansion. Suction and liquid line connectionsor supply and discharge con nections shallbe made on the same side of the coil. Part 1 - GENERAL 1.01 SYSTEM DESCRIPTION A. Indoor, packaged air-handling unit for use in commer cial split systems.Unit shall have a multiposition de sign and shall be capable of horizontal or vertical installation on a floor or in a ceiling, with or without ductwork. (Only vertical units are to be applied with out ductwork.) B. Unit with direct-expansioncoil shall be used in a re frigerant circuit with a matching air-cooled con densing unit. 1.02 QUALITY ASSURANCE A. Coils shall be designed & tested in accordance with ASHRAE 15 Safety Code for Mechanical Refrigera tion (U.S.A.), latest edition. B. Unit shall be constructed in accordance with ETL (U.S.A.) and ETL, Canada, standardsand shall carry the ETL and ETL, Canada, labels. C. Unit insulation and adhesive shall comply with NFPA-90A (U.S.A.)requirements for flame spread and smoke generation. 1. Direct-expansioncoilsshallfeaturefactory-installed thermostatic expansion valves (TXVs) for refrig erant control. The TXVs shall be capable of ex ternal adjustment. Direct-expansion heat pump coils shall have a factory-installedbypassline and check valve assemblyaround the TXVs to allow liquid flow from the coil to the outdoor unit during the heating mode. Coil tubing shall be internally rifled to maximize heat transfer. D. Unit shall be manufactured in a facility registered to the ISO 9002 manufacturing quality standard. E. Direct-expansionand chilled water coils shallbe burst and leak tested at 435 psi (2999 kPa). 1.03 DELIVERY AND STORAGE Units shall be stored and handled per manufacturer's recommendations. Par t 2 - Products 2.01 EQUIPMENT Indoor mounted, draw-thru, packaged air-handling unit that can be used in a suspended horizontal configu ration or a vertical configuration. Unit shall consistof forward-curved belt-driven centrifugal fan(s), motor & drive assembly,prewired fan motor contactor, factory installedrefrigerant metering devices(direct-expansion coil units), cooling coil, 1-in. (25.4-mm) washable air filters, and condensate drain pans for vertical or hori zontal configurations. C. Operating Characteristics: Unit shall be capable of providing cfm (L/s) airflow at an external static pressureof in. wg (kPag). D. Motor: Fan motor of the size and electrical characteristics specified on the equipment scheduleshall be factory supplied and installed. Motors rated at 1.3 through 3.7 hp (0.97 through 2.76 kW) shall have internal thermal overload pro tection. Motors rated at 5, 7 1/2 , and 10 hp (3.73, 5.60, and 7.46 kW) shall be protected by a circuit breaker. 63 51 E. Factory-InstalledOptions: 1. Alternate Motor and Drive: An alternate motor and/or medium- or high-static drive shall be available to meet the airflow and external static pressure requirements specified on the equipment schedule. 6. Thermostat Controls: a. Debonair programmablemulti-stagethermo statwith 7-dayclock, holiday scheduling,large ThermoglowŸ display, remote sensorcapa bility, and Title 24 compliance. b. TEMP System programmable communicat ing multi-stage thermostat with fan switch, time clock, LCD display,ÉF/ÉC capability,and CCN compatiblity. c. CommercialElectronicThermostatwith 7-day time clock, auto-changeover, multi-stageca pability, and large LCD temperature display. d. Non-programmablethermostatwith fan switch subbase. 7. Overhead SuspensionPackage: Package shall include necessary brackets to support units in a horizontal ceiling installation. 8. CO2 Sensor: Sensorshallprovide the ability to signalthe econo mizer to open when the spaceCO2 levelexceeds the predetermined set point. Sensor shall have the capability of being connected to Comfort System relay pack or to economizer using field supplied and -installed Honeywell dc adapter no. Q769C1004. 9. CondensateDrain Trap: Trap shall have transparent, serviceabledesign for easycleaning. Kit shallinclude overflow shut off switch and wiring harnessfor connection to an alarm if desired. F. Field-InstalledAccessories (ordered from NAO): 1. Electric Heaters: Heaters for nominal 240, 480, or 575-volt, 3-phase, 60 Hz; and 240, 400-volt, 3 phase, 50 Hz power supply shallbe factory-suppliedfor field installationasshown on the equipmentdraw ings. Electricheat assemblyshallbe ETL (U.S.A.) and ETL, Canada, agency approved, and shall have single-point power wiring. Heater assem bly shallincludecontactorswith 24-V coils, power wiring, 24-v control wiring terminal blocks, and a hinged accesspanel. Electric heaters shall not be used with air discharge plenum. 2. Air Discharge Plenum: Plenum shall be factory supplied to provide free blow air distribution for vertical floor-mounted units. A grille with moveable vanes for hori zontal or vertical airflow adjustment shall be included. Plenum shall be field-assembledand field-installedon the unit's fan deck for blow-thru air distribution. Plenum shall not be used with electric heaters. 3. Return Air Grille: Grille shall be factory supplied for field installa tion on the unit's return air opening. 4. Unit Subbase: Subbaseassemblyshall be factory supplied for field installation. Subbase shall elevate floormounted vertical units to provide access for correct condensate drain connection. 5. Economizer: Economizerfor ventilation or ``free'' cooling shall be factory provided for field installation on either return air opening of air handler. For free cool ing applications, economizershallbe compatible with separate thermostat; economizer dampers shall open when outdoor air enthalpy is suitable for free cooling. Economizershall be compatible with separate CO2 sensor accessory; economizer dampersshall open when indoor CO2 level rises abovepredetermined setpoint. Economizershall include enthalpy control and damper actuator. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 2010 52 Form 38AR-01 PD 50Hz CKAC
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1.1-111 Instance ID : uuid:f5eaa073-6eec-11df-9068-000393720206 Document ID : adobe:docid:indd:8c985e50-6b0f-11df-b9b7-8469e2b7dc1f Rendition Class : proof:pdf Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1, uuid:eae85c2c-890b-44c9-99a5-c0c012d6d1e1 Manifest Reference Document ID : uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8, uuid:cdfd9e8c-580c-4629-b183-76bf9f5222b8 Create Date : 2010:06:03 11:44:14+03:00 Modify Date : 2010:06:03 11:49:46+03:00 Metadata Date : 2010:06:03 11:49:46+03:00 Creator Tool : Adobe InDesign CS2 (4.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 10960 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 52 Creator : Adobe InDesign CS2 (4.0)EXIF Metadata provided by EXIF.tools