4016_201_RevEA 2 4016_201 4016 201
User Manual: 4016_201
Open the PDF directly: View PDF .
Page Count: 64
Download | |
Open PDF In Browser | View PDF |
Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Model 1199 Diaphragm Seal Systems (European Offering) FOR MODELS 3051C, 3051T, 1151, AND 2088 TRANSMITTERS EXPANDED TRANSMITTER USE • Extreme hot and cold temperatures • Corrosive applications • Clogging • Sanitary requirements APPLICATIONS • Level, Flow, Pressure, Interface, Density Contents “Specifications” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-282 “General Purpose Seals Selection Overview” . . . . . . . . . . . . . . . . . . . . page Pressure-286 “Ordering Information” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-290 “Diaphragm Seal Connections” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-291 “General Purpose Seal Assemblies” . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-294 “Sanitary Diaphragm Seal Systems” . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-328 “General Information” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-339 www.rosemount.com Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Specifications FILL FLUID SPECIFICATIONS TABLE 1. Fill Fluid Specifications Temperature Limits(1) Fill Fluid Pabs < 1 bara Pabs > 1 bara Specific Gravity Coeff. of Therm. Viscosity at 25 °C Recommended Exp. (cc/cc/°C) centistokes Capillary I. D. General Purpose Silicone Oil Inert Low Temperature Silicone Oil Sanitary Oil(2) High Temperature Silicone Oil(3) Vegetable, Sanitary Oil –45 to 100 °C –45 to 80 °C NA –15 to 120 °C 0 to 200 °C –45 to 205 °C –45 to 175 °C –75 to 150 °C –15 to 205 °C 0 to 315 °C 0,93 1,85 0,85 0,90 1,07 0,00108 0,000864 0,001199 0,001008 0,00095 9,5 6,5 1,6 9,8 44,0 All All All All 2 mm –10 to 120 °C –10 to 250 °C 0,91 0,0008 63,0 2 mm (1) Temperature unit of system based on lowest temperature option. (2) Select sanitary fill fluid for sanitary applications requiring faster response times. (3) Upper temperature limit is for capillary seal systems mounted away from the transmitter. Contact your Rosemount® representative for temperature limits above 315 °C. MINIMUM SPAN RECOMMENDATIONS These recommendations are based on the following: • Stainless steel diaphragm; standard thickness. Table 2 lists minimum span recommendations in mbar for Rosemount pressure transmitters as a function of the diameter of the diaphragm seal. Contact your Rosemount representative for minimum calibrated span recommendation for all in-line seal designs or seals with diameter less than 25mm. • Single-sided capillary length up to 5 m. • The diameter of the pressure sensor smaller than the diameter of the diaphragm seal. • Differential pressure systems are balanced. Consult Instrument ToolKit™ software or contact your Rosemount representative for a more detailed performance evaluation of diaphragm seal systems. TABLE 2. Minimum Span Recommendations (mbar) F.A. = Factory Approval required Differential Pressure Gauge Pressure Absolute Pressure dm (mm) 2 mm Cap ID 1 mm Cap ID 2 mm Cap ID 1 mm Cap ID 2 mm Cap ID 1 mm Cap ID 25 32 40 57 76 89 F.A. F.A. 750 100 25 4 F.A. F.A. 500 75 20 3 10000 2500 1500 500 150 20 10000 2000 1000 300 100 20 F.A. F.A. F.A. 1000 500 20 F.A. F.A. F.A. 750 350 20 Pressure-282 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 INDUSTRY STANDARDS Tables 3 and 4 list industry standards and their descriptions for General Purpose and Sanitary Seals. TABLE 3. Available Industry Standards for General Purpose Diaphragm Seals Standard Description DIN 2512 Form F DIN 2512 Form N DIN 2513 Form R-13 DIN 2513 Form V-13 DIN 2514 Form V-14 DIN 2514 Form R-14 DIN 2526 Form C, D or E DIN 2696 Form L ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 ANSI /ASME B16.5 Tongue Groove Large female face Large male face Male face Female face Raised face 'Linsen” gasket face Raised face Ring type joint Large male tongue Large female groove Large or small tongue face Large or small groove face Large or small male face Large or small female face TABLE 4. Available for Sanitary Diaphragm Seals Industry Standards(1) Standard Description SMS: Swedish Milk Standard IDF: International Dairy Federation RJT: Ring Joint Type DIN 11851 Female or male thread Female or male thread Female or male thread Female or male thread Sanitary Sanitary Sanitary Tri-Clamp® Tuchenhagen Varivent® Homogenizer Clamping Flange (1) Other standards are available upon request. GASKET SPECIFICATIONS Table 5 refers to the gaskets supplied with the diaphragm seal. TABLE 5. Gasket Specifications Gasket Temperature Limit (°C) PTFE(1) –160 to 230 °C –200 to 500 °C –20 to 200 °C –55 to 150 °C 98% Graphite(1) Viton®(2) Ethylene Propylene (1) Temperature limits are in standard circumstances. (2) Temperature limit in oxidizing atmosphere. Pressure-283 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TRANSMITTER SPECIFICATIONS Functional Specifications For complete functional, performance, and physical specifications for the Model 3051C, Model 3051T, Model 1151, and Model 2088 transmitters, refer to the respective product data sheets listed in this section. The transmitter pressure ranges and ordering codes for use with diaphragm seals are located in Section 4 of this document. TABLE 6. Transmitter Temperature Limits Summary. Models 3051C, 3051T Ambient –40 to 85 °C Storage –45 to 110 °C Process Silicone Sensor –40 to 120 °C Model 1151 S Electronics –40 to 85 °C E,G Electronics –30 to 95 °C S Electronics –50 to 85 °C E,G Electronics –50 to 120 °C –40 to 105 °C Model 2088 –40 to 85 °C Materials of Construction Transmitters Isolating Diaphragm Model 3051C: 316L SST Model 3051T: 316L SST Model 1151: 316L SST Model 2088: 316L SST Process Flange or Connector Model 3051C: 316 SST Model 3051T: 316L SST Model 1151: CF-8M (Cast Version of 316 SST, material per ASTM-A743) Model 2088: 316L SST –45 to 85 °C –40 to 120 °C Hazardous Locations Certifications Adding seals to the transmitter does not change the approval ratings of the individual transmitters. For complete approval listings, see the respective product data sheet for the pressure transmitter. Maximum Working Pressure of Transmitter–Seal System The maximum working pressure (MWP) of the transmitter–seal system is a function of the MWP of the transmitter and the remote seal. To determine the MWP of the transmitter–seal system, simply select the lesser value of the two. For safe operation, the MWP of the transmitter–seal system must not be exceeded. NACE Standard NACE (National Association of Corrosion Engineers) standard MR–01–75 defines metallic material requirements for resistance to sulfide stress cracking when exposed to sour environments. Contact your Rosemount representative to aid in selecting the proper materials in order for Rosemount diaphragm seals to meet the NACE standard. Zero Elevation and Suppression Output Codes S, E, and G Zero elevation and suppression must be such that the lower range value is greater than or equal to the (–URL) and the upper range value is less than or equal to the (+URL). The calibrated span must be greater than or equal to the minimum span. Pressure-284 PHYSICAL SPECIFICATIONS O-ring Model 3051C: Glass-filled TFE Model 3051T: None Model 1151: Viton or Buna N Model 2088: None Sensor Module Fill Fluid Silicone Oil Bolts (Models 3051C and 1151 only) Plated Carbon Steel or 316 SST Electronics Housing Low-copper aluminum or CF-8M (cast version of 316 SST, material per ASTM-A743), NEMA 4X, IP66 Paint Polyurethane Cover O-rings Buna-N Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Electrical Connection Model 3051C, 3051T, and Model 2088 1/2–14 NPT, PG 13.5, G1/2 Female (PF1/2 Female, or M20 ⫻ 1.5 Female (CM20) conduit entry) Model 1151 1 /2–14 NPT conduit with screw terminals and integral test jacks compatible with miniature banana plugs (Pomona 2944, 3690, or equivalent) Model 3051C, 3051T, and Model 1151 Smart HART®-based The terminal block. communicator connections are fixed to the Transmitter Weight The transmitter/seal system weight depends on the type of capillary and seal: Model 3051C 2,5 kg without options Model 3051T 1,4 kg without options Model 1151 5,5 kg without options Model 1199 Calibration Transmitters are factory calibrated to customer’s specified range. If calibration is not specified, then the transmitters are calibrated at maximum range. Calibration is performed at ambient temperature and pressure. Four and 20 mA points must be the same unit of measure. Available units of measure: inH2O inHg ftH2O mmH2O bar kg/cm2 torr mmHg mbar Pa atm psi g/cm2 kPa Custom Configurations Model 3051C (Option Code C1) If code C1 is ordered, the customer may specify the following data in addition to the standard configuration parameters. Refer to Configuration Data Sheet 00806-0100-4001. Model 1151 (Option Code C9) If Options Code C9 is ordered, the customer may specify the following data in addition to the standard configuration parameters. Refer to Configuration Data Sheet 00806-0100-4593. Descriptor: 16 alphanumeric characters Message: 32 alphanumeric characters Date: Day, month, year Damping: Sec. Model 2088 1,0 kg without options Standard Accessories All models are shipped with flange adapters, drain/vent valves, and one instruction manual per shipment. Tagging The pressure transmitter will be tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is wired to the transmitter. Tag is 0,051 cm thick with 0,318 cm high letters. A permanently attached tag is available upon request. Pressure-285 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 General Purpose Seals Selection Overview Diaphragm Seal Selection Guides Diaphragm Seal Selection Guide Seal Type Flush Flanged Type (FFS, FUS) (see page Pressure-294) General Applications Usual Application and Type of Service Gasket Surface Type DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Serrated Finish ANSI/ASME B16.5 Smooth Finish DIN 2512 Form F DIN 2512 Form N DIN 2513 Form V-13 DIN 2513 Form R-13 DIN 2514 Form V-14 DIN 2514 Form R-14 Process DN 25 1 in. Connection Size DN 40 11/2 in. DN 50 2 in. DN 80 3 in. DN 100 4 in. DN 125 5 in. Flange PN 16 Class 150 Pressure Rating PN 40 Class 300 PN 64 Class 400 PN 100 Class 600 PN 160 Class 900 PN 250 Class 1500 PN 400 Class 2500 Diaphragm and 316LSST Wetted Parts Monel® 400® Material/ Upper 316Ti SST (WNr 1.4571) Housing Material Titanium Gr2 Hastelloy® C-276®,B-2®,C-22 Zirconium Inconel 600® Tantalum Nickel 201 Flushing Ring 316L SST Material 316Ti SST (WNr 1.4571) Hastelloy C-276 Duplex 1.4462 Options Direct Mount Connection Material Traceability Gold-coated 5 m Teflon®-coated Diaphragm Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Pressure-286 RTJ Flush Flanged Type (FCS) (see page Pressure-301) High Pressure Applications RTJ 1in. 11/2 in. 2 in. 3 in. 4 in. 5 in. Class 150 Class 300 Class 400 Class 600 Class 900 Class 1500 Class 2500 316LSST 316Ti SST (WNr 1.4571) Hastelloy C-276 Duplex 1.4462 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Duplex 1.4462 Direct Mount Connection Material Traceability Teflon-coated Diaphragm Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Extended Flanged Type (EES, EFS) (see page Pressure-303) Insulated Processes DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Serrated Finish ANSI/ASME B16.5 Smooth Finish DN 50 2 in. DN 80 3 in DN 100 4 in. DN 125 5 in. PN 16 Class 150 PN 40 Class 300 PN 64 Class 400 PN 100 Class 600 PN 160 Class 900 PN 250 Class 1500 PN 400 Class 2500 316LSST Nickel 201 316Ti SST (WNr 1.4571) Monel 400 Hastelloy C-22, C-276, B-2 Inconel 600 Tantalum Titanium Gr2 Flush Pancake (Cell) Type (PFS) (see page Pressure-308) General Applications DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Serrated Finish ANSI/ASME B16.5 Smooth Finish DN 25 1 in. DN 40 11/2 in. DN 50 2 in. DN 80 3 in. DN 100 4 in. DN 125 5 in. PN 16-400 Class 150–2500 316LSST Nickel 201 316Ti SST (WNr 1.4571) Titanium Gr2 Hastelloy C-276, B-2, C-22 Monel 400 Zirconium Tantalum Inconel 600 Not Applicable 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Duplex 1.4462 Direct Mount Connection Material Traceability Material Traceability Cold Temperature Fill Custom Extension Lengths Gold-coated 5 m Cold Temperature Fill Teflon-coated Diaphragm 50 m Diaphragm Thickness 50 m Diaphragm Thickness 150m Diaphragm Thickness 150m Diaphragm Thickness Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Diaphragm Seal Selection Guide Seal Type Usual Application and Type of Service Gasket Surface Type Process Connection Size Extended Pancake (Cell) Type (DES, DFS) (see page Pressure-311) Insulated Processes Internal Flanged Type (RFS) (see page Pressure-316) Small Process Connections DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Serrated Finish ANSI/ASME B16.5 Smooth Finish DIN 2512 Form N DIN 2512 Form F DIN 2513 Form V-13 DI 2513 Form R-13 DIN 2514 Form V-14 DIN 2514 Form R-14 DN 50 2 in. DN 80 3 in. DN 100 4 in. DN 125 5 in. DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Serrated Finish ANSI/ASME B16.5 Smooth Finish Flange Pressure Rating PN 16–400 Class 150–2000 Diaphragm and Wetted Parts Material 316LSST Nickel 201 316Ti SST (WNr 1.4571) Monel 400 Inconel 600 Tantalum Titanium Gr2 Hastelloy C-276, C-22, B-2 Not Applicable Lower Housing (Flushing) Material Options Material Traceability Teflon-coated Diaphragm Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Custom Extension Lengths DN 15 1 in. 1 DN 20 /2 in. 3/4 in. DN 25 DN 32 11/4 in. DN 40 11/2 in. PN 40 Class 150 PN 64 Class 300 PN 100 Class 600 PN 160 316LSST Nickel 201 316Ti SST (WNr 1.4571) Monel 400 Inconel 600 Tantalum Hastelloy C-276, C-22, B-2 Titanium Gr 2 Hastelloy C-276 316L SST 316Ti SST (WNr 1.4571) Direct Mount Connection Material Traceability Gold-coated 5 m Teflon-coated Diaphragm Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Teflon-lined Lower Housing Internal Threaded Type (RTS) (see page Pressure-319) Small Process Connections High Pressures Not Applicable Parallel Thread: G1/2A DIN 16288 Tapered Thread: R1/2A per ISO 7/1 1/2–14 NPT 1–11.5 NPT PN 40 PN 100 PN 250 316LSST Monel 400 316Ti SST (WNr 1.4571) Tantalum Inconel 600 Nickel 201 Hastelloy C-276, C-22, B-2 Titanium Gr 2 Hastelloy C-276 316L SST 316Ti SST (WNr 1.4571) Direct Mount Connection Material Traceability Teflon-coated Diaphragm Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Pressure-287 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Diaphragm Seal Selection Guide Seal Type Usual Application and Type of Service Gasket Surface Type Threaded Flush Type (HTS) (see page Pressure-322) High Process Pressures Chemical, Food, Paint, Pulp and Paper Industries Dependent on Thread Type Process Connection Size G1 G11/2 G2 Pressure Rating 600 Bar Diaphragm and Wetted Parts Material/ Upper Housing Material Options 316L SST 316Ti SST (WNr 1.4571) Pressure-288 1-11.5 NPT 11/2-11.5 NPT 2-11.5 NPT Material Traceability Cold Temperature Fill 50 m Diaphragm Thickness 150 m Diaphragm Thickness Direct Mount In-Line Cell Type (TFS) (see page Pressure-324) Eliminate Process Dead Ends High Viscosity Fluids Extruder Flanged Type (JES) (see page Pressure-326) Plastic Extrusion High Temperature DIN 2526 Form D DIN 2526 Form E ANSI/ASME B16.5 Smooth Finish DN 25 1 in. DN 40 11/2 in. DN 50 2 in. DN 80 3 in. DN 100 4 in. PN 16-400 Class 150-2500 316L SST 316Ti SST (WNr 1.4571) Extrusion Clamping Flange Material Traceability Integral Flange Construction Direct Mount to Model 3051T or Model 2088 Material Traceability 150 m Diaphragm Thickness Custom Extension Lengths Jock Screws Direct Mount Special for Extruders 400 bar 316L SST 316Ti SST (WNr 1.4571) Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Sanitary Seal Selection Overview Sanitary Seal Selection Guide Seal Type Usual Application and Type of Service Connection Type In-Line Sanitary Type (VLS, VMS) (see page Pressure-328) Food and Pharmaceutical Industries High Viscosity Fluids Eliminate Process Dead Ends DIN 11851 Male SMS Male Process Connection Size DN 25 1 in. DN 40 11/2 in. DN 50 2 in. DN 80 3 in. DN 100 4 in. Pressure Rating 40 bar Diaphragm Material 316L SST 316Ti SST (WNr 1.4571) Options Electro-polished Diaphragm Material Traceability Dairy Type (SLS, SMS, SFS, SRS) (see page Pressure-330) Sanitary and Food Industry Dairy Type (MLS,MMS, MFS, MRS) (see page Pressure-332) Sanitary and Food Industry DIN 11851 Female SMS Female IDF Female RJT Female DN 25 DN 65 DN 32 DN 80 DN 40 DN 100 DN 50 DIN 11851 Male SMS Male IDF Male RJT Male DN 25 DN 65 DN 32 DN 80 DN 40 DN 100 DN 50 40 Bar 316L SST 316Ti SST (WNr 1.4571) Electro-polished Diaphragm Material Traceability 40 Bar 316L SST 316Ti SST (WNr 1.4571) Electro-polished Diaphragm Material Traceability In-Line Sanitary Tri-Clamp (VCS) (see page Pressure-334) Food and Pharmaceutical Industries High Viscosity Fluids Eliminate Process Dead Ends Tri-Clamp DN 25 1 in. DN 40 11/2 in. DN 50 2 in. DN 80 3 in. DN 100 4 in. 40 Bar 316L SST 316Ti SST (WNr 1.4571) Material Traceability Electro-polished Diaphragm Sanitary Seal Selection Guide Seal Type Sanitary Tri-Clamp Type (SCS) (see page Pressure-335) Usual Application Sanitary and Food Industry and Type of Service Process Tri-Clamp Connection Size Pressure Rating 40 bar Diaphragm Material 316L SST 316Ti SST (WNr 1.4571) Options Electro-polished Diaphragm Material Traceability Counterpiece, Gasket and Clamp Sanitary Tank Spud Type (EES) (see page Pressure-336) Sanitary and Food Industry Spud-Ring with EthylenePropylene O-ring Standard 40 bar 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Electro-polished Diaphragm Material Traceability Counterpiece and Gasket Tuchenhagen Varivent Compatible Connection (see page Pressure-337) Sanitary and Food Industry Tuchenhagen Varivent Homogenizer Clamping Flange (CHS) (see page Pressure-338) Homogenizers Special for Homogenizers 40 bar 316L SST 316Ti SST (WNr 1.4571) 600 bar 316L SST Electro-polished Diaphragm Material Traceability Counterpiece and Gasket Material Traceability 150 m Diaphragm Thickness Pressure-289 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Ordering Information HOW TO ORDER A ROSEMOUNT SEAL/TRANSMITTER SYSTEM The following steps outline the transmitter/seal system ordering process. Please review the entire procedure before specifying a transmitter/seal system model number. Step 1. Select a Pressure Transmitter Model Number Refer to the Pressure Transmitters product data sheets below to select a transmitter model number. For additional transmitter information, see the following product data sheets: Model 3051S Series: PDS 00813-0100-4801 Model 3051C and 3051T: PDS 00813-0100-4001 3. Combine the two sets of model numbers to create one model number string. This completes a valid seal assembly model number. Example: Combine the model strings in steps A and B above for a complete seal assembly model number string: “1199MD256 DFFSJGLA00 AZ.” NOTE FOR SPECIAL CONFIGURATIONS It is possible to order two different seal assemblies for one transmitter. Use the seal location code to specify the attachment location for both the high and low side seals. For example, suppose a direct mount seal is required on the high pressure side of the Model 3051 All-Welded System and a seal with a 3 m capillary is required for the low pressure side. In this example, the order may look like the following: Model 2088: PDS 00813-0100-4690 Model 1151: PDS 00813-0100-4360 Step 2. Select a Seal Assembly Model Number 1. Use Table 1 on page 282 or Table 8 on page 293 to specify a Capillary or Direct Mount Fill Fluid code (nine characters). Example: Using: “1199MD256...” is typical of the first half of a seal assembly model number. • Include a code from each section of the table. 2. Use the Seal tables beginning on page Pressure-291 to specify the Diaphragm Seal Configuration. Example: Using Table 9 on page 295(FFS Flanged Type Seals): “...DFFSJGLA00” is typical of the second half of a seal assembly model number. • Include a code from each section of the table. • Include as many options as desired from the Options (Multiple Selections) section. Example: The customer wants to add a vacuum resistant gasket and material traceability per DIN EN10204 3.1.B to his order. The model string becomes DFFSJGLA00 AZ. Pressure-290 Quantity Model Number 1 1 1 3051CD4A22A1AS9 (From Step 1) 1199WDAD6 DFFSJGLA00 (From Step 2) 1199MD356 DFFSJGLA00 (From Step 2) CAUTION While it is possible to combine different types of seals, fill fluid and capillary lengths, be aware that performance may be more affected by some combinations than others. Consult with your local Rosemount representative for assistance in seal selection. Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Diaphragm Seal Connections (NOTE: Use Table 7 to order Capillary type connections. Use Table 8 to order Direct Mount type connections.) Capillary/Fill Fluid TABLE 7. Capillary/Fill Fluid Ordering Information(1) Model 1199 Type Diaphragm Seal Code Seal Location Capillary Connections P R Seal on High Pressure Side of Transmitter Seal on High Pressure Side of Transmitter All welded system All welded system S Seal on Low Pressure Side of Transmitter (use with Model 1199T) Seal on High Pressure Side of Transmitter (requires Model 1199S on low side) Same Seal on Both High and Low Pressure Sides of Transmitter Seal on High Pressure Side of Transmitter Seal on Low Pressure Side of Transmitter All welded system T D W M All welded system Welded Welded Welded Transmitter Type Models 3051S2T, 3051T, 2088 Model 3051S2C (option code B11) Model 3051S2C (option code B12) Model 3051S2C (option code B12) Differential Transmitters All Transmitters Differential Transmitters Temperature Limits Code D C(2) A H N 4 Code 2 3 5 6 Code 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Fill Fluid Pabs < 1 bara Pabs > 1 bara Specific Gravity General Purpose Silicone Oil D.C. 704 Low Temperature Silicone Oil Inert Sanitary Oil Vegetable, Sanitary Oil –45 to 100 °C 0 to 200 °C N/A –45 to 80 °C –15 to 120 °C –10 to 120 °C –45 to 205 °C 0 to 315 °C –75 to 150 °C –45 to 175 °C –15 to 205 °C –10 to 250 °C 0,93 1,07 0,85 1,85 0,90 0,91 Capillary Inside Diameter (mm) Material 1 mm 2 mm 1 mm 2 mm SST Armored Sleeving and Support Tubes SST Armored Sleeving and Support Tubes SST Armored Polyethylene Sleeving and Support Tubes SST Armored Polyethylene Sleeving and Support Tubes Capillary Connection Length 0,5 m 1,0 m 1,5 m 2,0 m 2,5 m 3,0 m 3,5 m 4,0 m 5,0 m 6,0 m 7,0 m 8,0 m 9,0 m 10,0 m 11,0 m 12,0 m 13,0 m 14,0 m 15,0 m Table continued on next page Pressure-291 Product Data Sheet Model 1199 00813-0201-4016, Rev EA Catalog 2002 – 2003 TABLE 7. Capillary/Fill Fluid Ordering Information(1) Code Capillary Connection Length 70(3) 71(3) 72(3) 73(3) 74(3) 75(3) 76(3) 77(3) 78(3) 79(3) 80(3) 81(3) 82(3) 83(3) 84(3) 16 m 17 m 18 m 19 m 20 m 21 m 22 m 23 m 24 m 25 m 26 m 27 m 28 m 29 m 30 m (1) Shaded Areas indicate special orders. Consult your Rosemount representative for configuration availability, performance effect, and lead time. (2) Not available with seal connection code M. (3) Consult your Rosemount representative to perform performance effect calculation. Pressure-292 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Direct Mount Connection Type/Fill Fluid TABLE 8. Direct Mount/Fill Fluid Ordering Information(1) Model 1199 Code W P R T Type Diaphragm Seal Seal Location Connection Type Transmitter Type Seal on High Pressure Side of Transmitter Seal on High Pressure Side of Transmitter Seal on High Pressure Side of Transmitter Seal on High Pressure Side of Transmitter Welded All welded system All welded system All welded system All Transmitters Models 3051T, 2088, and 3051S2T Model 3051S2C (option code B11) Model 3051S2C (option code B12) Temperature Limits(2) Code Fill Fluid Pabs < 1 bara Pabs > 1 bara Specific Gravity D General Purpose Silicone Oil –45 to 100 °C –45 to 205 °C 0,93 C High Temperature Silicone Oil 0 to 200 °C 0 to 260 °C 1,07 A Low Temperature Silicone Oil N/A –75 to 150 °C 0,85 H Inert –45 to 80 °C –45 to 175 °C 1,85 N Sanitary Oil –15 to 120 °C –15 to 205 °C 0,90 4 Vegetable, Sanitary Oil –10 to 120 °C –10 to 250 °C 0,91 Code A Code Connection Type Direct Mount Connection Direct Mount Connection Type WELDED CONNECTION TYPE: Models 3051C and 3051S Transmitters (use with seal code W) Attachment of One Diaphragm Seal, Model 3051C Transmitter Option Code S1 or Model 3051S2C with B11 process connection code. B3 One Diaphragm Seal System, 50 mm Connection D3 One Diaphragm Seal System, 100 mm Connection ALL WELDED CONNECTION TYPE: Models 3051C and 3051S all welded system (use with seal codes R or T) Attachment of One Diaphragm Seal, Model 3051C Transmitter Option Code S0 or Model 3051S2C with B11 process connection code B7 One Diaphragm Seal System, 50 mm Connection D7 One Diaphragm Seal System, 100 mm Connection Attachment of Two Diaphragm Seals, Model 3051C (use with seal code W) Transmitter Option Code S2 or Model 3051S2C with B12 process connection code B4 Two Diaphragm Seal System, 50 mm Direct Mount Connection and Capillary Connection D4 Two Diaphragm Seal System, 100 mm Direct Mount Connection and Capillary Connection Attachment of Two Diaphragm Seals, Model 3051C Transmitter Option Code S9 or Model 3051S2C with B12 process connection code B6 Two Diaphragm Seal System, 50 mm Direct Mount Connection and Capillary Connection D6 Two Diaphragm Seal System, 100 mm Direct Mount Connection and Capillary Connection WELDED OR ALL WELDED CONNECTION TYPE: Model 3051T Transmitter 95 One Diaphragm Seal System, 25 mm Connection, all welded (use with code P) or welded (use with code W) A5 One Diaphragm Seal System, 50 mm Connection WELDED CONNECTION TYPE: Model 1151 Transmitter (use with seal code W) 92 One or Two Diaphragm Seal System. One Direct Mount, One Direct Mount and One Capillary Mount, or Two Capillary Mount Configuration Available WELDED OR ALL WELDED CONNECTION TYPE: Model 2088 Transmitter 95 One Diaphragm Seal System, 25 mm Connection, all welded (use with code P) or welded (use with code W) A5 One Diaphragm Seal System, 50 mm Connection (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Fill fluid maximum operating temperature is limited by heat transfer to transmitter electronics. Teckperature limit for Model 3051C 100 mm Direct Mount system is 260 °C and 205 °C for all other direct mount connection types at 21 °C ambient temperature. The temperature limit for the Model 1151 and 2088 Direct Mount systems is 205 °C. Pressure-293 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 General Purpose Seal Assemblies FFS Flanged Type: Flush Diaphragm Seals 1199-0FDFA01A 1199-HSAB01A Dimensional Drawing for FFS Flanged Type: Flush Diaphragm Seals d2 f 1199-067AB b dm d4 k D Dimensional Drawing for FFS Flushing Connection Ring Flushing Ring Dimensions (mm) b G b/2 d40 DN d40 d4 b G 50 80 2 in. 3 in. 59 91 59 91 102 138 92 127 20 20 20 20 ¼-18 NPT ¼-18 NPT ¼-18 NPT ¼-18 NPT d4 FFS Process Connection Dimensions DIN 2501 ANSI/ASME B16.5 RF Dimensions (mm) DN 25 40 50 80 100 125 (1) PN 40 100 160 40 100 160 40 64 100 40 64 100 16 40 64 16 40 64 Dimensions (mm) dm D b d2 k f d4 (2) 25 25 25 40 40 40 57 57 57 89 89 89 89 89 89 124 124 124 108 124 124 127 155 155 152 165 165 190 210 210 229 254 254 254 279 279 14 18 18 17 21 22 19 22 25 24 28 32 24 32 35 24 35 38 4x16 4x19 4x19 4x16 4x22 4x22 4x19 8x19 8x19 4x19 8x22 8x22 8x19 8x22 8x25 8x22 8x22 8x25 79 89 89 98 114 114 121 127 127 152 168 168 190 200 200 216 235 235 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 51 51 51 73 73 73 92 92 92 127 127 127 157 157 157 186 186 186 dm D b d2 k f d4 DN CL 25 25 25 40 40 40 57 57 57 89 89 89 89 89 89 124 124 124 115 140 140 150 170 170 165 180 195 200 215 230 220 235 250 250 270 295 18 24 24 18 28 28 20 26 28 24 28 32 20 24 30 22 26 34 4x14 4x18 4x18 4x18 4x22 4x22 4x18 4x22 4x26 8x18 8x22 8x26 8x18 8x22 8x26 8x18 8x26 8x30 85 100 100 110 125 125 125 135 145 160 170 180 180 190 200 210 220 240 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 68 68 68 88 88 88 102 102 102 138 138 138 158 162 162 188 188 188 1 in. 150 300 600(3) 150 300 600(3) 150 300 600(3) 150 300 600(3) 150 300 400 150 300 400 (1) Dimensions for other flange ratings are available upon request. (2) d4 dimensions only valid for full 316 SST execution. (3) Class 600 flanges add 0.63 mm to flange thickness dimension for raised face. Pressure-294 (1) 1.5 in. 2 in. 3 in. 4 in. 5 in. Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 9. FFS Flanged Type: Flush Diaphragm Seal – DIN Ordering Information(1) Code D Code F Code FS Code G J D F K M Code G E H J K Code LA LB LC WW WB LM LJ LP L4 LV LZ LE Industry Standard DIN 2501 (Deutsches Institut für Normung) Process Connection Style Flanged Type: Flush Diaphragm Seal Gasket Surface Type(2) DIN 2526 Form D Process Connection Size DN 50 DN 80 DN 25 DN 40 DN 100 DN 125 Flange Pressure Rating PN 40 PN 16 PN 64 PN 100 PN 160 Diaphragm and Wetted Parts Material(3) Upper Housing Material (includes flange) 316L SST Hastelloy C-276 Tantalum 316Ti SST (WNr 1.4571) Hastelloy C-276 Titanium GR.2 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Zirconium Inconel 600 316 SST 316 SST 316 SST 316Ti SST (WNr 1.4571) 316 SST (WNr 1.4571) 316 SST (Only available with a smooth gasket surface) 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST Table continued on next page Pressure-295 Product Data Sheet Model 1199 00813-0201-4016, Rev EA Catalog 2002 – 2003 TABLE 9. FFS Flanged Type: Flush Diaphragm Seal – DIN Ordering Information(1) Code 0 L W B Code 0 1 3 7 9 Code 0 V G H Z 2 5 8 U B D 1 T Flushing Ring Material No Flushing Ring required 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options No Flushing Ring required One 1/4–18 NPT Flushing Connection Two 1/4–18 NPT Flushing Connection One 1/2-–14 NPT Flushing Connection Two 1/2–14 NPT Flushing Connection Options (Multiple Selections) None Teflon Coated Diaphragm for nonstick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) SST Plug(s) for Flushing Connections(s) SST Vent/Drain for Flushing Connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) Radial Capillary Connection 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Materials (Hastelloy C-276 is only available with a smooth gasket surface) Gold Coated 5 micron Extra Fill for Cold Temperature Applications Hastelloy Plug(s) for Flushing Connection(s) Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless otherwise noted. Consult your Rosemount representative for use with spiral wound gaskets. Pressure-296 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 10. FFS Flanged Type: Diaphragm Seal — ANSI/ASME Ordering Information(1) Code A Code F Code FS Code Industry Standard ANSI/ASME B 16.5 (American Standards Institute/American Society of Mechanical Engineers) Process Connection Style Flanged Type: Flush Diaphragm Seal Gasket Surface Type (2) Serrated Finish Process Connection Size G 2 in. 7 3 in. 2 1 in. 4 11/2 in. 9 4 in. B 5 in. Code Flange Pressure Rating 1 Class 150 2 Class 300 3 Class 400 4 Class 600 5 Class 900 6 Class 1500 7 Class 2500 Diaphragm and Wetted Parts Material (3) Upper Housing Material (include flange) LA 316L SST 316 SST Code LB Hastelloy C-276 316 SST LC Tantalum 316 SST WB Hastelloy C-276 316 SST (WNr 1.4571) LM Titanium GR.2 316 SST (Only available with a smooth gasket surface) LJ Hastelloy B-2 316 SST LP Nickel 201 316 SST L4 Hastelloy C-22 316 SST LV Monel 400 316 SST LZ Zirconium 316 SST LE Inconel 600 316 SST Table continued on next page Pressure-297 Product Data Sheet Model 1199 00813-0201-4016, Rev EA Catalog 2002 – 2003 TABLE 10. FFS Flanged Type: Diaphragm Seal — ANSI/ASME Ordering Information(1) Code Flushing Ring Material 0 No Flushing Ring required L 316L SST W 316Ti SST (WNr 1.4571) B Hastelloy C-276 Code Flushing Options 0 No Flushing Ring required 1 One 1/4–18 NPT Flushing Connection 3 Two 1/4–18 NPT Flushing Connection 7 One 1/2-–14 NPT Flushing Connection 9 Two 1/2–14 NPT Flushing Connection Code Options (Multiple Selections) 0 None V Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) G SST Plug(s) for Flushing Connections(s) H SST Vent/Drain for Flushing Connection(s) Z Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 2 Radial Capillary Connection 5 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 8 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material U Gold Coated 5 micron (Hastelloy C-276 is only available with a smooth gasket surface) B Extra Fill for Cold Temperature Applications D Hastelloy Plug(s) for Flushing Connection(s) 1 Zone 0 Execution PTB Nr. III B/S 2415 T NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless otherwise noted. Consult your Rosemount representative for use with spiral wound gaskets. Pressure-298 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 FUS Flanged Type: Flush Diaphragm Seal—DIN 2512 Form N Gasket Surface 1199-FDFB01A Dimensional Drawing for FUS Flanged Type: Flush Diaphragm Seals— DIN 2512 Form N Gasket Surface d2 b 1199-068AB dm d41 d44 d4 k D f2 f FUS Process Connection Dimensions DIN 2512 Form N(1) Dimensions (mm) DN PN dm D b d2 k f f2 d4(2) d41 d44 25 40 100 160 40 100 160 40 64 160 40 64 100 16 40 64 16 40 64 25 25 25 40 40 40 57 57 57 89 89 89 89 89 89 124 124 124 115 140 140 150 170 170 165 180 195 200 215 230 220 235 250 250 270 295 18 24 24 18 26 28 20 26 28 24 28 32 20 24 30 22 26 34 4x14 4x14 4x14 4x18 4x22 4x26 4x18 4x22 4x26 4x18 4x22 4x26 4x18 4x22 4x26 8x18 8x26 8x30 85 100 100 110 125 125 125 135 145 160 170 180 180 190 200 210 220 240 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 0 3, 5 3, 5 3, 5 3, 5 3, 5 3, 5 68 68 68 88 88 88 102 102 102 138 138 138 158 162 162 188 188 188 42 42 42 60 60 60 72 72 72 105 105 105 128 128 128 154 154 154 58 58 58 76 76 76 88 88 88 121 121 121 150 150 150 176 176 176 40 50 80 100 125 (1) Dimensions for other flange ratings are available upon request. (2) d4 dimensions only valid for full stainless steel 316 execution. Dimensional Drawing for FUS Flushing Connection Ring Flushing Ring Dimensions (mm) d43 d42 f1 g b b/2 d40 d41 d44 d4 DN PN d40 d4 d42 d43 f1 d41 d44 f2 b 50 10-100 59 102 73 87 4 72 88 2.5 20 80 10-100 91 138 106 120 4 105 121 2.5 20 g 1 /4-18 NPT 1 /4-18 NPT f2 Pressure-299 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 11. FUS Flanged Type: Flush Diaphragm Seal – DIN Ordering Information(1) Code D Code F Code US VS GS HS JS KS Code G J D F K M Code G E H J K Industry Standard DIN 2501 (Deutsches Institut für Normung) Process Connection Style Flanged Type: Flush Diaphragm Seal Gasket Surface Type DIN 2512 Form N Contact Surface–up to PN 160 DIN 2512 Form F Contact Surface–up to PN 160 DIN 2513 Form V-13 Contact Surface–up to PN 100 DIN 2513 Form R-13 Contact Surface–up to PN 100 DIN 2514 Form V-14 Contact Surface–up to PN 40 DIN 2514 Form R-14 Contact Surface–up to PN 40 Process Connection Size Diaphragm Diameter DN 50 DN 80 DN 25 DN 40 DN 100 DN 125 57 mm 89 mm 32 mm 40 mm 89 mm 124 mm Flange Pressure Rating PN 40 PN 16 PN 64 PN 100 PN 160 Code Diaphragm and Wetted Parts Material(2) Upper Housing Material (includes flange) LA LB(3) LC(3) LV(3) 316L SST Hastelloy-C 276 Tantalum Monel 400 316 SST 316 SST 316 SST 316 SST Code 0 L W Code 0 1 3 7 9 Code 0 V G H Z 2 5 8 U B D 1(4) T Flushing Ring Material No Flushing Ring required 316L SST 316Ti SST (WNr 1.4571) Flushing Options No Flushing Ring required One 1/4–18 NPT Flushing Connection Two 1/4–18 NPT Flushing Connection One 1/2–14 NPT Flushing Connection Two 1/2–14 NPT Flushing Connection Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) SST Plug(s) in Flushing Connection(s) SST Vent/Drain in Flushing Connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) Radial Capillary Connection 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Gold Coated 5 Micron Extra Fill for Cold Temperature Applications Hastelloy Plug(s) for Flushing Connection(s) Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (3) Requires selecting DIN 2512 Form N contact surface type (Option Code US). (4) Only available for DFUS. Pressure-300 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 FCS Flanged Type: Flush Diaphragm Seal—RTJ Gasket Surface 1199-0000C04A Dimensional Drawing for FCS Flanged Type: Flush Diaphragm Seal—RTJ Gasket Surface d2 dm P d4 k D E 1199–069AB b F FCS Process Connection Dimensions ASME B16.5 RTJ(1) Dimensions (mm) DN CL dM D b d2 k d4 E F P 1-in. 600 1500 2500 600 1500 2500 600 1500 2500 600 900 1500 2500 32 32 32 40 40 40 57 57 57 89 89 89 89 124 149 159 155 178 205 165 216 235 210 241 267 305 18 28 35 22 32 44 25 38 51 32 38 48 67 4x19 4x25 4x25 4x22 4x28 4x32 8x19 8x25 8x28 8x22 8x25 8x32 8x35 89 102 108 114 124 146 127 165 171 168 190 203 229 70 70 83 90 92 114 108 124 133 146 155 168 168 6,3 6,3 6,3 6,3 6,3 6,3 7,9 7,9 7,9 7,9 7,9 7,9 9,5 8,7 8,7 8,7 8,7 8,7 12 12 12 12 12 12 12 13,5 51 51 60 68 68 83 83 95 102 124 124 136 127 1½-in. 2-in. 3-in. (1) Dimensions for other flange ratings are available upon request Dimensional Drawing for FCS Flushing Connection Ring b 2 d40 P Kmin R 1199-0000A09A b G 1) Dimensions will be provided upon request. Pressure-301 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 12. FCS Flanged Type: Flush Diaphragm Seal - ANSI/ASME Ordering Information(1) • = Available - = Not Available Code Industry Standard A Code ANSI/ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Style F Code Flanged Type: Flush Diaphragm Seal Gasket Surface Type CS Code ASME B16.5 RTJ: Ring Type Joint Facing Process Connection Size G 7 2 4 9 B Code 2 in. 3 in. 1 in. 11/2 in. 4 in. 5 in. Flange Pressure Rating 4 5 6 7 1 2 3 Code(2) Class 600 Class 900 Class 1500 Class 2500 Class 150 Class 300 Class 400 Diaphragm 1 in. LA LB BB VI VB Code 316L SST Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 Flushing Ring Material 0 L W B 2 Code No Flushing Ring required 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Duplex 1.4462 Flushing Options 0 1 3 7 9 Code No Flushing Ring required One 1/4-18 NPT Flushing Connection Two 1/4-18 NPT Flushing Connection One 1/2--4 NPT Flushing Connection Two 1/2--4 NPT Flushing Connection Options (Multiple Selections) 0 2 V G H Z 5 8 B D T 11/2 in. • • • • • • • • • • Wetted Parts Material 316L SST 316L SST Hastelloy C-276 Duplex 1.4462 Hastelloy C-276 2 in. • • • • • - 3 in. 4 in. • • • • • • • • • Upper Housing Material 316 SST 316 SST 316 SST Duplex 1.4462 Duplex 1. None Radial Capillary Connection - Available with 316L SST or 316Ti SST (WNr 1.4571) diaphragms only Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C-276 diaphragm only) SST Plug(s) in Flushing Connection(s) SST Vent/Drain in Flushing Connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 mm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 mm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Extra Fill for Cold Temperature Applications Hastelloy Plug(s) for Flushing Connection(s) NACE MR-01-75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Pressure-302 5 in. • • • Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 EFS Flanged type: Extended Diaphragm Seals Dimensional Drawing for EFS Flanged Type: Extended Diaphragm Seal 1199-0000A02A d2 b f 1199-070AB x d d5 d4 k D EFS Process Connection Dimensions DIN 2501 ANSI/ASME B16.5 Dimensions (mm) Dimensions (mm) DN PN(1) dm D b d2 k f d4 d5 50 40 64 100 40 64 100 16 40 64 16 40 64 40 40 40 72 72 72 89 89 89 124 124 124 165 180 195 200 215 230 220 235 250 250 270 295 20 26 28 24 28 32 20 24 30 22 26 34 4x18 4x22 4x26 8x18 8x22 8x26 8x18 8x22 8x26 8x18 8x26 8x30 2 125 135 145 160 170 180 180 190 200 210 220 240 3 3 3 3 3 3 3 3 3 3 3 3 102 102 102 138 138 138 158 162 162 188 188 188 48 48 48 76 76 76 94 94 94 125 125 125 80 100 125 DN CL(2) dm D b d2 k f d4 d5 2 in. 150 300 600(3) 150 300 600(3) 150 300 400 150 300 400 40 40 40 72 72 72 89 89 89 124 124 124 152 165 165 190 210 210 229 254 254 254 279 279 19 22 25 24 28 32 24 32 35 24 35 38 4x19 8x19 8x19 4x19 8x22 8x22 8x19 8x22 8x25 8x22 8x22 8x25 121 127 127 152 168 168 190 200 200 216 235 235 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 92 92 92 127 127 127 157 157 157 186 186 186 48 48 48 76 76 76 94 94 94 125 125 125 3 in. 4 in. 5 in. Standard Extension Lengths x (2) DIN Standard Extension Lengths x(1) ANSI/ASME Standard Extension Lengths x (1) 50 mm 50 mm 2 in 100 mm 150 mm 200 mm 100 mm 150 mm 200 mm 4 in. 6 in. 8 in. (1) Other extension lengths are available upon request. (1) Dimensions for other flange ratings are available upon request. (2) Other extension lengths and diameter are available upon request. (3) Class 600 flanges add 0.63 mm to flange thickness dimension for raised face. Pressure-303 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 13. EES and EFS Flanged Type: Extended Diaphragm Seal – DIN Ordering Information(1) Code D Code E Code FS Code G J K M Code E G H J K Code LA LB LM LC LD LR LJ LP L4 LV LE Code 2 4 6 8 0 1 3 5 7 9 Code 0 8 1 2 3 4 5 6 7 9 Industry Standard DIN 2501 (Deutsches Institut für Normung) Process Connection Style Flanged Type: Extended Diaphragm Seal Gasket Surface Type DIN 2526 Form D Process Connection Size DN 50 DN 80 DN 100 DN 125 Flange Pressure Rating PN 16 PN 40 PN 64 PN 100 PN 160 Diaphragm Material(2) Extension/Gasket Surface Material Flange/ Upper Housing Material 316L SST Hastelloy C-276 Hastelloy C-276 Tantalum (Only available with smooth gasket surface) Tantalum Titanium GR.2 (Only available with smooth gasket surface) Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Inconel 600 316L SST Hastelloy C-276 316L SST Tantalum 316 SST 316 SST 316 SST 316 SST 316L SST Titanium GR.2 316 SST 316 SST Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Inconel 600 316 SST 316 SST 316 SST 316 SST 316 SST Extension Length (3) 50 mm 100 mm 150 mm 200 mm 0 mm 25 mm 75 mm 125 mm 175 mm 225 mm Extension Length (Amount to Add) (3) Add 0 mm Add 20 mm Add 2,5 mm Add 5 mm Add 7,5 mm Add 10 mm Add 12,5 mm Add 15 mm Add 17,5 mm Add 22,5 mm Continued on next page Pressure-304 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 13. EES and EFS Flanged Type: Extended Diaphragm Seal – DIN Ordering Information(1) Code 0 6 7 V Z 2 5 8 B 1(4) T Options (Multiple Selections) None Add 250 mm Extension Length Add 500 mm Extension Length Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Material Traceability per EN10204 DIN 3.1.B (Requires Selection of Transmitter Code Q8) Radial Capillary Connection - Available with 316L SST or 316Ti SST (WNr 1.4571) Diaphragm Material only 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Extra Fill for Cold Temperature Applications Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time (2) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Consult your Rosemount representative for use with spiral wound gaskets. (3) DIN extension lengths are specified in millimeters as offered. Additional lengths are available as special orders. Consult factory. (4) Only available for DEFS Pressure-305 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 14. EES and EFS Flanged Type: Extended Diaphragm Seal –ANSI Ordering Information(1) Code A Code E Code FS ES Code G 7 9 B Code 1 2 3 4 5 6 7 Code LA LB LM LC LD LR LJ LP L4 LV LE Code 2 4 6 8 0 1 3 5 7 9 Code 0 1 2 3 4 5 6 7 Industry Standard ANSI/ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Style Flanged Type: Extended Diaphragm Seal Gasket Surface Type Serrated Finish Smooth Finish (2) Process Connection Size 2 in. 3 in. 4 in. 5 in. Flange Pressure Rating Class 150 Class 300 Class 400 Class 600 Class 900 Class 1500 Class 2500 Diaphragm Material(3) Extension/Gasket Surface Material Flange/Upper Housing Material 316L SST Hastelloy C-276 Hastelloy C-276 Tantalum (Only available with smooth gasket surface) Tantalum Titanium GR.2 (Only available with smooth gasket surface) Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Inconel 600 316L SST Hastelloy C-276 316L SST Tantalum 316 SST 316 SST 316 SST 316 SST 316L SST Titanium GR.2 316 SST 316 SST Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Inconel 600 316 SST 316 SST 316 SST 316 SST 316 SST Extension Length(4) 2 in. 4 in. 6 in. 8 in. 0 in. 1 in. 3 in. 5 in. 7 in. 9 in. Extension Length (Amount to Add) Add 0 in. Add 1/8 in. Add 1/4 in. Add 3/8 in. Add 1/2 in. Add 5/8 in. Add 3/4 in. Add 7/8 in. Continued on next page Pressure-306 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 14. EES and EFS Flanged Type: Extended Diaphragm Seal –ANSI Ordering Information(1) Code 0 V Z 2 5 6 7 8 B 1(5) T Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Material Traceability per EN10204 DIN 3.1.B (Requires Selection of Transmitter Code Q8) Radial Capillary Connection - Available with 316L SST or 316Ti SST (WNr 1.4571) Diaphragms only 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) Add 10-in. Extension Length Add 20-in. Extension Length 150 µm Diaphragm Thickness - 316L or Hastelloy C-276 Diaphragm Material only Extra Fill for Cold Temperature Applications Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Select for Tantalum wetted parts only. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Consult your Rosemount representative for use with spiral wound gaskets. (4) ANSI extension lengths are in inches as offered. Additional lengths are available as special orders. Consult factory. (5) Only available for AEFS. Pressure-307 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 PFS Pancake (Cell) Type: Flush Diaphragm Seals Dimensional Drawing for PFS Pancake (Cell) Type: Flush Diaphragm Seal 1199-FDFD01A, 0004ab b dm d4 PFS Process Connection Dimensions DIN 2501 ANSI/ASME B16.5 Dimensions (mm) Dimensions (mm) DN PN dm b d4 DN PN dm b d4 25 50 80 100 125 16–400 16-400 16-400 16-400 16-400 25 57 89 89 124 20 20 20 20 20 68 102 138 158 188 1 in. 11/2 in. 2 in. 3 in. 4 in. 5 in. 150-2500 150-2500 150-2500 150-2500 150-2500 150-2500 25 40 57 89 89 124 20 20 20 20 20 20 51 73 92 127 157 186 Dimensional Drawing for PFS Flushing Connection Ring Flushing Ring Dimensions (mm) b b/2 d40 d4 Pressure-308 HSAB01A G DN d40 d4 b G 50 80 2 in. 3 in. 59 91 59 91 102 138 92 127 20 20 20 20 ¼–18 NPT ¼–18 NPT ¼–18 NPT ¼–18 NPT Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 15. PFS Pancake (Cell) Type: Flush Diaphragm Seal – DIN Ordering Information(1) Code D Code Industry Standard DIN 2501 (Deutsches Institut für Normung) Process Connection Style P Code Pancake (Cell) Type: Flush Diaphragm Seal Gasket Surface Type(2) FS Code DIN 2526 Form D Process Connection Size G J D F K M Code DN 50 DN 80 DN 25 DN 40 DN 100 DN 125 Pressure Rating Diaphragm Diameter 57 mm 89 mm 25 mm 40 mm 89 mm 124 mm 0 Code Flanged not supplied. Seal rated to PN 16-400 or flange ratings or as indicated Diaphragm and Wetted Parts Material(3) Upper Housing Material LA LB LC LE LM LJ LP L4 LV LZ Code 316L SST Hastelloy C-276 Tantalum Inconel 600 Titanium GR.2 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Zirconium Flushing Ring Material 0 L W B Code No Flushing Ring 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options 0 1 3 7 9 Code No Flushing Ring One 1/4–18 NPT Flushing Connection Two 1/4–18 NPT Flushing Connection One 1/2–14 NPT Flushing Connection Two 1/2–14 NPT Flushing Connection Options (Multiple Selections) 0 V G H Z 5 8 B D 1 T 316 SST 316 SST 316 SST 316 SST 316 SST (Only available with a smooth gasket surface) 316 SST 316 SST 316 SST 316 SST 316 SST None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) SST Plug(s) in Flushing Connection(s) SST Vent/Drain in Flushing Connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L or Hastelloy C-276 Diaphragm Material only (Hastelloy C-276 is only available with a smooth gasket surface) Extra Fill for Cold Temperature Applications Hastelloy Plug(s) for Flushing Connection(s) Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Consult your Rosemount representative for use with spiral wound gaskets. Pressure-309 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 16. PFS Pancake (Cell) Type: Flush Diaphragm Seal – ANSI/ASME Ordering Information(1) Code Industry Standard A Code ANSI/ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Style P Code Pancake (Cell) Type: Flush Diaphragm Seal Gasket Surface Type(2) FS Code Serrated Finish Process Connection Size G 7 9 B 2 4 Code 2 in. 3 in. 4 in. 5 in. 1 in. 11/2 in. Flange Pressure Rating 0 Code Flange not supplied; seal rated to Class 150–2500 or flange rating Diaphragm and Wetted Parts Material(3) LA LB LC LE LM LJ LP L4 LV LZ Code 316L SST Hastelloy C-276 Tantalum Inconel 600 Titanium GR.2 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Zirconium Flushing Ring Material 0 L W B Code No Flushing Ring 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options 0 1 3 7 9 Code No Flushing Ring One 1/4-18 NPT Flushing Connection Two 1/4-18 NPT Flushing Connection One 1/2-14 NPT Flushing Connection Two 1/2-14 NPT Flushing Connection Options (Multiple Selections) 0 V G H Z 5 8 B D 1 T Diaphragm Diameter 57 mm 89 mm 89 mm 124 mm 25 mm 40 mm Upper Housing Material 316 SST 316 SST 316 SST 316 SST 316 SST (Only available with a smooth gasket surface) 316 SST 316 SST 316 SST 316 SST 316 SST None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) SST Plug(s) in Flushing Connection(s) SST Vent/Drain in Flushing Connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only (Hastelloy C-276 is only available with a smooth gasket surface) Extra Fill for Cold Temperature Applications Hastelloy Plug(s) for Flushing Connection(s) Zone 0 Execution PTB Nr. III B/S 2415 NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless otherwise noted. Consult your Rosemount representative for use with spiral wound gaskets. Pressure-310 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 DES and DFS Pancake (Cell) Type: Extended Diaphragm Seals 1199-0006AB Dimensional Drawing for DES and DFS Pancake Type: Extended Diaphragm Seals DIN Standard Extension Lengths x(1) ANSI/ASME Standard Extension Lengths x (1) 50 mm 2 in 100 mm 4 in. 150 mm 6 in. 200 mm 8 in. (1) Other extension lengths are available upon request. x dm d5 d4 1199-EDB01A b DES and DFS Pancake (Cell) Process Connection Dimensions DIN 2501 ANSI/ASME B16.5 Dimensions (mm) Dimensions (mm) DN PN dm b d4 d5 DN CL dm b d4 d5 50 80 100 125 16-400 16-400 16-400 16-400 40 72 89 124 20 20 20 20 102 138 162 188 48 76 94 125 2 in. 3 in. 4 in. 5 in. 150-2500 150-2500 150-2500 150-2500 40 72 89 124 20 20 20 20 92 127 157 186 48 76 94 125 Pressure-311 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 17. DES and DFS Pancake (Cell) Type: Extended Diaphragm Seal – DIN Ordering Information(1) Code Industry Standard D Code DIN 2501 (Deutsches Institut für Normung) Process Connection Style D Code Pancake (Cell) Type: Extended Diaphragm Seal Gasket Surface Type FS ES Code DIN 2526 Form D DIN 2526 Form E (2) Process Connection Size G J K M DN 50 DN 80 DN 100 DN 125 Code Pressure Rating 0 Code Flange not supplied; seal rated to PN 16-400 or flange rating Diaphragm Material(3) Extension/Gasket Surface Material LA LB LC LJ LP L4 LV LD LM Code 316L SST Hastelloy C-276 Tantalum (Only available with smooth gasket surface) Inconel 600 Titanium GR.2 (Only available with smooth gasket surface) Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Tantalum Hastelloy C-276 Extension Length(4) 2 4 6 8 0 1 3 5 7 9 Code 50 mm 100 mm 150 mm 200 mm 0 mm 25 mm 75 mm 125 mm 175 mm 225 mm Extension Length (Amount to Add)(3) LE LR 0 1 2 3 4 5 6 7 8 9 316 SST 316 SST 316 SST Inconel 600 Titanium GR.2 316 SST 316 SST Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 316L SST 316L SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST Add 0 mm Add 2,5 mm Add 5 mm Add 7,5 mm Add 10 mm Add 12,5 mm Add 15 mm Add 17,5 mm Add 20 mm Add 22,5 mm Continued on next page Pressure-312 Upper Housing Material 316L SST Hastelloy C-276 Tantalum Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 17. DES and DFS Pancake (Cell) Type: Extended Diaphragm Seal – DIN Ordering Information(1) Code 0 V Z 5 8 6 7 B T Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Add 250 mm Extension Length Add 500 mm Extension Length Extra Fill for Cold Temperature Applications NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Select for Tantalum wetted parts only. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Consult your Rosemount representative for use with spiral wound gaskets. (4) DIN extension lengths are specified in millimeters, as offered. Other extension lengths are available as special offers on request. Pressure-313 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 18. DES and DFS Pancake (Cell) Type: Extended Diaphragm Seal – ANSI/ASME Ordering Information(1) Code A Code D Code FS ES Code G 7 9 B Code 0 Code LA LB LC LE LR LJ LP L4 LV LD LM Code 2 4 6 8 0 1 3 5 7 9 Code 0 1 2 3 4 5 6 7 Industry Standard ANSI/ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Style Pancake (Cell) Type: Extended Diaphragm Seal Gasket Surface Type Serrated Finish Smooth Finish (2) Process Connection Size 2 in. 3 in. 4 in. 5 in. Pressure Rating Flange not supplied; seal rated to Class 150–2500 or flange rating Diaphragm Material (3) Extension/Gasket Surface Material Upper Housing Material 316L SST Hastelloy C-276 Tantalum (Only available with smooth gasket surface) Inconel 600 Titanium GR.2 (Only available with smooth gasket surface) Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Tantalum Hastelloy C-276 316L SST Hastelloy C-276 Tantalum 316 SST 316 SST 316 SST Inconel 600 Titanium GR.2 316 SST 316 SST Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 316L SST 316L SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST Extension Length(4) 2 in. 4 in. 6 in. 8 in. 0 in. 1 in. 3 in. 5 in. 7 in. 9 in. Extension Length (Amount to Add) Add 0 in Add 1/8 in Add 1/4 in. Add 3/8 in. Add 1/2 in. Add 5/8 in. Add 3/4 in. Add 7/8 in. Continued on next page Pressure-314 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 18. DES and DFS Pancake (Cell) Type: Extended Diaphragm Seal – ANSI/ASME Ordering Information(1) Code 0 V Z 5 8 6 7 B T Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L or Hastelloy C-276 Diaphragm Material Only Add 10-in. Extension Length Add 20-in. Extension Length Extra Fill for Cold Temperature Applications NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Select for Tantalum wetted parts only. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. Consult your Rosemount representative for use with spiral wound gaskets. (4) ANSI extension lengths are specified in inches as offered. Other extension lengths are available as special offers on request. Pressure-315 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 RFS Flanged Type: Internal Diaphragm Seals Dimensional Drawing for RFS Flanged Type: Internal Diaphragm Seal B dm n 1199-071AB h H f d4 k D 1199–IDFB01A d2 b RFS Dimensions for Process Flange to Lower Housing Connection DIN 2501 ANSI/ASME B16.5 Dimensions (mm) Dimensions (mm) DN PN(1) D b f d2 k d4 H ca. DN CL(1) D b f d2 k d4 H ca. 15 40 100 160 95 105 105 16 20 20 2 2 2 4x14 4x14 4x14 65 75 75 45 45 45 94 101 101 1/2-in. 150 300 600 150 300 600 150 300 600 150 300 600 150 300 600 89 95 95 98 117 117 108 124 124 117 133 133 127 155 155 11 14 14 13 16 16 14 18 18 16 19 21 18 21 22 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 1,5 1,5 6,3 4x16 4x16 4x16 4x16 4x19 4x19 4x16 4x19 4x19 4x16 4x19 4x19 4x16 4x22 4x22 60 66 66 70 83 83 79 89 89 89 99 99 99 114 114 35 35 35 43 43 43 51 51 51 64 64 64 73 73 73 104 108 108 108 113 113 112 118 118 113 121 123 118 124 126 3/4-in. 20 25 40 105 18 2 4x14 75 58 96 40 100 160 115 140 140 18 24 24 2 2 2 4x14 4x18 4x18 85 100 100 68 68 68 96 114 114 40 140 18 2 4x18 100 78 98 40 100 160 150 170 170 18 26 28 3 3 3 4x18 4x22 4x22 110 125 125 88 88 88 101 118 120 32 40 1-in. 11/4-in . 11/2-in . (1) Dimensions for other flange ratings are available upon request. RFS Dimensions for Upper Housing to Lower Housing Connection PN B dm n h 40 100(1) 100 160 138 95 124 95 89 57 72 57 8xM10 4xM10 8xM10 8xM10 42 42 42 42 (1) Factory standard upper housing dimensions. Other upper housing dimensions optional. Contact your local Rosemount representative for additional information. Pressure-316 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 19. RFS Flanged Type: Internal Diaphragm Seal — DIN Ordering Information(1) Code Industry Standard D Code DIN 2501 (Deutsches Institut für Normung) R Code Flanged Type: Internal Diaphragm Seal FS Code DIN 2526 Form D B C D E F Code DN 15 DN 20 DN 25 DN 32 DN 40 Process Connection Type Gasket Surface Type(2) Process Connection Size Flange Pressure Rating G J K Code(3) PN 40 PN 100 (n/a with DN 20 or DN 32) PN 160 Diaphragm Material LA LB LC LE LJ LP L4 LV LZ WC WB Code(4) 316L SST Hastelloy C-276 Tantalum Inconel 600 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Zirconium Tantalum Hastelloy C-276 Lower Housing Material (Supplied with Viton Gasket)(5) L W B Code 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options 1 3 5 Code One 1/4-18 NPT Flushing Connection Two 1/4-18 NPT Flushing Connection No Flushing Connection Options (Multiple Selections) 0 2 V D G H Z J 5 8 U B 6 7 T Diaphragm Size 57 mm 57 mm 57 mm 57 mm 57 mm Upper and Lower Housing Material 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST (WNr 1.4571) 316 SST (WNr 1.4571) None 98% Graphite Gasket Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Hastelloy Plug(s) for flushing connection(s) SST Plug(s) for flushing connection(s) SST Vent/Drain for flushing connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) Teflon Gasket 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L or Hastelloy C-276 Diaphragm Material only Gold Coated Diaphragm (5 microns) Extra Fill for Cold Temperature Applications 72 mm Diaphragm Diameter (up to PN 100) 89 mm Diaphragm Diameter (PN 40 only) NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (4) Other gasket materials are available upon request. (5) Limited to a process temperature of 200 °C. Pressure-317 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 20. RFS Internal Flanged Diaphragm Seal — ANSI/ASME Ordering Information(1) Code Industry Standard A Code ANSI /ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Type R Code Flanged Type: Internal Diaphragm Seal Gasket Surface Type(2) FS Code Serrated Finish Process Connection Size 1 A 2 3 4 Code 1/2 in. 3/4 in. 1 in. 1 ¼in. 1 ½ in. Flange Pressure Rating 1 2 3 Code(3) Class 150 Class 300 Class 600 Diaphragm Material LA LB LC LE LJ LP L4 LV WC WB Code(4) 316L SST Hastelloy C-276 Tantalum Inconel 600 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Tantalum Hastelloy C-276 Lower Housing Material (Supplied with Viton Gasket)(5) L W B Code 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options 1 3 5 Code One 1/4-18 NPT Flushing Connection Two 1/4-18 NPT Flushing Connection No Flushing Connection Options (Multiple Selections) 0 2 V D G H Z 5 8 U B 6 7 T Diaphragm Size 52 mm 52 mm 52 mm 52 mm 52 mm Upper and Lower Housing Material 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST (WNr 1.4571) 316 SST (WNr 1.4571) None 98% Graphite Gasket for chloride applications Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Hastelloy Plug(s) for flushing connection(s) SST Plug(s) for flushing connection(s) SST Vent/Drain for flushing connection(s) Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L or Hastelloy C-276 Diaphragm Material only Gold Coated Diaphragm (5 microns) Extra Fill for Cold Temperature Applications 72 mm Diaphragm Diameter (up to Class 600) 89 mm Diaphragm Diameter (up to Class 300) NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Other gasket surfaces are possible; consult factory for coding and availability. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (4) Other gasket materials are available upon request. (5) Limited to a process temperature of 200 °C. Pressure-318 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 RTS Threaded Type: Internal Diaphragm Seal Dimensional Drawing for RTS Threaded Type: Internal Diaphragm Seal B dm 1199-0000A11A 1199-060AB h n G1 RTS Threaded Process Connection Dimensions Parallel Thread Tapered Thread Dimensions (mm) PN G1(1) 100 250 100 40 1/2 in. 1/2 in. 1 /2 in. /2 in. 1 dm 57 57 72 89 B 95 95 124 138 n 4xM10 8xM10 8xM10 8xM10 Dimensions (mm) h 42 42 42 42 PN G1(1) dm B n h 100 250 100 40 1/2 in. 57 57 72 89 95 95 124 138 4xM10 8xM10 8xM10 8xM10 42 42 42 42 1/2 in. 1 /2 in. /2 in. 1 (1) Others available upon request (1/2-14NPT male shown). Pressure-319 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 21. RTS Threaded Type: Internal Diaphragm Seal — Ordering Information(1) Code Process Connection Style DRTS Threaded (Standard thread is male; for female, see options below) Code(2) Parallel thread: G1/2A DIN 16288 Tapered thread: R1/2 per ISO 7/1 C N Code 1 2 4 Code Pressure Rating (3) Code L W B Code 1 3 5 Code Diaphragm Size 57 mm PN 100 PN 250 PN 40 LA LB LC LE LJ LP L4 LV WC WB EM 0 V J 2 Z 5 8 9 H G B D 6 T Process Connection Size 57 mm 89 mm Diaphragm Material Upper Housing Material 316L SST Hastelloy C-276 Tantalum Inconel 60 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Tantalum Hastelloy C-276 Titanium Gr.2 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST (WNr 1.4571) 316 SST (WNr 1.4571) Titanium Gr.2 Lower Housing Material (Supplied with Viton Gasket)(4) 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 Flushing Options One ¼–18NPT Flushing Connection Two ¼–18 NPT Flushing Connection No Flushing Connection Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Teflon Gasket 98% Graphite Gasket for chloride applications Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Female Threads (Internal parallel thread G1/2A–DIN 16288, internal tapered thread R1/2–ISO 7/1) SST Drain/Vent for flushing connection(s) SST Plug(s) for flushing connection(s) Extra Fill for Cold Temperature Applications Hastelloy Plugs for Flushing Connections 72 mm Diaphragm Diameter NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) For special process connection sizes, contact your Rosemount representative. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (4) Limited to a process temperature of 200 °C. Pressure-320 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 22. RTS Threaded Type: Internal Diaphragm Seal — Ordering Information(1) Code Process Connection Style ARTS Tapered Threaded (Standard thread is female, for male, see options below) Code(2) 3 5 Code 1 2 4 Code(3) LA LB LC LE LJ LP L4 LV WC WB EM Code L W B P(5) Code 1 3 5 Code 0 V J 2 Z 5 8 1 H G B D 6 T Process Connection Size 1/2–14 NPT 1–14 NPT Pressure Rating Diaphragm Size PN 100 PN 250 PN 40 57 mm 57 mm 89 mm Diaphragm Material Upper Housing Material 316L SST Hastelloy C-276 Tantalum Inconel 60 Hastelloy B-2 Nickel 201 Hastelloy C-22 Monel 400 Tantalum Hastelloy C-276 Titanium Gr.2 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST 316 SST (WNr 1.4571) 316 SST (WNr 1.4571) Titanium Gr.2 Lower Housing Material (Supplied with Viton Gasket)(4) 316L SST 316Ti SST (WNr 1.4571) Hastelloy C-276 PVDF Flushing Options One ¼–18NPT Flushing Connection Two ¼–18 NPT Flushing Connection No Flushing Connection Options (Multiple Selections) None Teflon Coated Diaphragm for non-stick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Teflon Gasket 98% Graphite Gasket for chloride applications Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only NPT Male Threads SST Drain/Vent for flushing connection(s) SST Plug(s) for flushing connection(s) Extra Fill for Cold Temperature Applications Hastelloy Plugs for Flushing Connections 72 mm Diaphragm Diameter NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) For special process connection sizes, contact your local Rosemount representative. (3) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (4) Limited to a process temperature of 200 °C. (5) Pressure rating reduced. Contact your Rosemount representative for details. Pressure-321 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 HTS Threaded Type: Flush Diaphragm Seal Dimensional Drawing for HTS Threaded Type: Flush Diaphragm Seal b 1199-073AB L 1199-0000A05A dm G1 d HTS Process Connection Dimensions ISO 228/1 Parallel Thread NPT: Tapered Thread Dimensions (mm) Pressure-322 Dimensions (mm) G1 PN dm L b d G1 PN dm L b d 1 in. 1½ in. 2 in. 600 600 600 25 32 40 21 30 35 30 30 30 47 60 70 1 in. 1½ in. 2 in. 600 600 600 25 32 40 23 32 37 30 30 30 47 60 70 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 23. HTS Threaded Type: Flush Diaphragm Seal — DIN Ordering Information(1) Code DHTS(2) Code E G J Code 6 Process Connection Style Parallel Thread Process Connection Size Diaphragm Diameter G1 G11/2 G2 25 mm 32 mm 40 mm Pressure Rating 600 bar Code Diaphragm and Wetted Parts Material Housing Material LA00 316L SST 316 SST Code 0 Z 5 8 B T Options (Multiple Selections) None Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy C-276) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Extra Fill for Cold Temperature Applications NACE MR–01–75 (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) Gasket available upon request; contact your Rosemount representative. TABLE 24. HTS Threaded Type: Flush Diaphragm Seal —NPT Ordering Information (1) Code Process Connection Style AHTS Tapered Thread Code 5 7 9 Code 6 Process Connection Size Diaphragm Diameter 1-11,5 NPT 1½-11,5 NPT 2-11,5 NPT 25 mm 32 mm 40 mm Pressure Rating 600 bar Code Diaphragm and Wetted Parts Material Housing Material LA00 316L SST 316L SST Code 0 Z 5 8 B T Options (Multiple Selections) None Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) 50 µm Diaphragm Thickness (available in 316L SST or Hastelloy C-276) 150 µm Diaphragm Thickness - 316L SST or Hastelloy C-276 Diaphragm Material only Extra Fill for Cold Temperature Applications NACE MR–01–75 (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. Pressure-323 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TFS Cell Type: In-Line Diaphragm Seal 1199-000A012A, RWIB01A 1199-0074AB Dimensional Drawings for TFS Cell Type: In-Line Diaphragm Seal DN D L TFS Process Connection Dimensions DIN 2501 ANSI/ASME B16.5 Process Connection Size PN DN D 25 40 50 80 100 16-400 16-400 16-400 16-400 16-400 27 41,0 50 78,0 107 68 88 102 138 162 Pressure-324 Dimensions (mm) L Process Connection Size Dimensions (mm) CL DN D L 90 90 90 90 90 1 in. 1½ in. 2 in. 3 in. 4 in. 150-2500 150-2500 150-2500 150-2500 150-2500 27 41,0 50 78,0 101 51 73 92 127 157 90 90 90 90 90 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 25. TFS Cell Type: In-Line Diaphragm Seal —DIN Ordering Information(1) Code D Code T Code FS Code D F G J K Code 0 Code LA00 LB00 Code(3) 0 Z T Industry Standard DIN 2501 (Deutsches Institut für Normung) Process Connection Style Flanged Type: In-Line Diaphragm Seal Gasket Surface DIN 2526 Form D Process Connection Size DN 25 DN 40 DN 50 DN 80 DN 100 Pressure Rating Flange not supplied; seal rated to PN 16-400 or flange rating Diaphragm and Wetted Parts Material(2) 316L SST Hastelloy C-276 Options (Multiple Selections) None Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) NACE MR–01–75 Housing Material 316 SST 316 SST (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (3) Other lengths and integral flange construction available. Consult the factory. TABLE 26. TFS Cell Type: In-Line Diaphragm Seal —ANSI/ASME Ordering Information(1) Code Industry Standard A Code ANSI/ASME B16.5 (American National Standards Institute/American Society of Mechanical Engineers) Process Connection Style T Code Flanged Type: In-Line Diaphragm Seal Gasket Surface FS Code Serrated Finish Process Connection Size 2 4 G 7 9 Code 1 in. 1½ in. 2 in. 3 in. 4 in. Pressure Rating 0 Code Flange not supplied; seal rated to Class 2500 or flange rating Diaphragm and Wetted Parts Material(2) LA00 LB00 Code(3) 0 Z T 316L SST Hastelloy C-276 Options (Multiple Selections) Housing Material 316L SST 316L SST None Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) NACE MR–01–75 (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) When ordering special diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (3) Other lengths and integral flange construction available. Consult factory. Pressure-325 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 JES Extruder Flanged Type Dimensional Drawings for JES Extruder Flanged Type D K 5 dM RL 13.4 35 JES Process Connection Dimensions (mm) Pressure-326 PN dM D K d2 RL Flange Thickness 400 bar 23 85 54 4x14 See Table 27 25 mm 1199-1199004B, 1199-NCESA01C d2 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 27. JES Extruder Flanged Type — Ordering Information(1) Code Process Connection Style NJES Code Plastics Extrusion Clamping Flange Process Connection Size B Code 23 mm (minimum span 60 bar) Pressure Rating P(2) Code 400 bar Diaphragm and Wetted Parts Material LA Code 316L SST Extension Length 0 1 2 3 4 5 6 7 8 9 Code Add 0 mm Add 10 mm Add 20 mm Add 30 mm Add 40 mm Add 50 mm Add 60 mm Add 70 mm Add 80 mm Add 90 mm Extension Length (Amount to Add) 0 1 2 3 4 5 6 7 8 9 Code Add 0 mm Add 1 mm Add 2 mm Add 3 mm Add 4 mm Add 5 mm Add 6 mm Add 7 mm Add 8 mm Add 9 mm Options (Multiple Selections) 0 5 8 6 7 Z T Upper Housing Material 316 SST None 50 mm Diaphragm Thickness (available in 316L SST or Hastelloy) 150 mm Diaphragm Thickness (316L SST or Hastelloy C-276 Diaphragm Material Only) Add 100 mm extension length Add 200 mm extension length Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter Code Q8) NACE MR–01–75 (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) Minimum range is 100 bar. Pressure-327 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Sanitary Diaphragm Seal Systems VLS and VMS Sanitary In-Line Diaphragm Seals— DIN 11851 or SMS Process Connections DN 1199-RWIC01A, 1199-075AB Dimensional Drawing for VLS and VMS Sanitary In-Line Diaphragm Seals G1 L VLS and VMS Process Connection Dimensions(1) DIN 11851(1) SMS Process Connection Size Dimensions (mm) PN DN G1 L 25 40 50 80 100 40 40 40 40 40 25,0 38,1 50 81,0 100,0 Rd52x1/6 Rd65x1/6 Rd78x1/6 Rd110x1/4 Rd130x1/4 90 90 90 90 90 (1) RJT and IDF dimensions available upon request. Pressure-328 Process Connection Size Dimensions (mm) PN DN G1 L 25 38 51 76 40 40 40 40 25,0 38,1 50 76,0 Rd40x1/6 Rd60x1/6 Rd70x1/6 Rd98x1/6 90 90 90 90 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 28. VLS Sanitary In-Line Diaphragm Seal—DIN Ordering Information(1) Code S Code VLS Code D0 F0 G0 J0 K0 Code LA00 Code 0 6 Z Industry Standard Sanitary Process Connection Style(2) Sanitary In Line Seal per DIN 11851 (maximum working pressure: 40 bar) Process Connection Size DN 25 DN 40 DN 50 DN 80 DN 100 Diaphragm Material(3) 316L SST Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) Other industry standards such as IDF and RJT available upon request. (3) When ordering optional diaphragm materials, the standard housing material is 316L SST, unless noted otherwise. TABLE 29. VMS Sanitary In-Line Diaphragm Seal—SMS Ordering Information(1) Code S Code VMS Code 20 30 50 70 Code LA00 Code 0 6 Z Industry Standard Sanitary Process Connection Style(2) Sanitary In Line Seal per SMS (maximum working pressure: 40 bar) Process Connection Size DN 25 DN 38 DN 51 DN 76 Diaphragm Material(3) 316L SST Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) (1) Consult your Rosemount representative for use with low calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) Other industry standards such as IDF and RJT available upon request. (3) When ordering optional diaphragm materials, the standard housing material is 316L SST, unless noted otherwise. Pressure-329 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 SLS, SMS, SFS and SRS Sanitary Seals: Dairy Process Connections—Female Thread Dimension Drawing for SLS, SMS, SFS and SRS: Dairy Process Connections—Female Thread b 1199-0000B07A, A dm G1 D SLS, SMS, SFS and SRS Process Connection Dimensions Female Thread DIMENSIONS (mm) STANDARD DN PN A b dm G1 D DIN 11851 25 32 40 50 65 80 25 32 38 51 63,5 76 40 40 40 40 40 40 40 40 40 40 40 40 21 21 21 22 25 30 20 22 25 26 30 32 45 40 45 46 47 47 38 40 40 40 40 40 25 32 40 57 57 72 25 32 32 57 57 72 Rd52⫻1/6 Rd58⫻1/6 Rd65⫻1/6 Rd78⫻1/6 Rd95⫻1/6 Rd110⫻1/4 Rd40⫻1/6 Rd48⫻1/6 Rd60⫻1/6 Rd70⫻1/6 Rd85⫻1/6 Rd98⫻1/6 63 70 78 92 112 127 51 60 74 84 100 114 SMS IDF(1) RJT(1) (1) Contact factory for dimensions. Pressure-330 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 30. SLS Sanitary Seals: Dairy Process Connection—Female Thread Ordering Information(1) Code S Code SLS Code D0 F0 G0 J0 E0 H0 Industry Standard Sanitary Process Connection Style Female Thread per DIN 11851 Process Connection Size Pressure Rating(2) DN 25 DN 40 DN 50 DN 80 DN 32 DN 65 40 bar 40 bar 40 bar 40 bar 40 bar 40 bar Code Diaphragm Material LA00 316L SST Code 0 6 Z 2 Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Counterpiece (tank/pipe spud) and Gasket (ethylene propylene standard gasket material) (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lea d time. (2) Maximum working pressure is dependent on the pressure rating of the connection. TABLE 31. SMS, SFS and SRS Sanitary Seals: Dairy Process Connection—Female Thread Ordering Information(1) Code S Industry Standard Sanitary Code Process Connection Style SMS SFS SRS Female Thread per SMS Standard Female Thread per IDF Standard Female Thread per RJT Standard Code Process Connection Size 30 50 20 60 70 (11/2 in.) DN 38 DN 51 (2 in.) DN 25 DN 63.5 DN 76 Code Diaphragm Material LA00 316L SST Code 0 6 Z 2 Pressure Rating(2) 40 bar 40 bar 40 bar 40 bar 40 bar Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Counterpiece (tank/pipe spud) and Gasket (ethylene propylene standard gasket material) (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lea d time. (2) Maximum working pressure is dependent on the pressure rating of the connection. Pressure-331 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 MLS, MMS, MFS and MRS Sanitary Seal: Dairy Process Connections—Male Thread Dimensional Drawing for MLS, MMS, MFS and MRS: Dairy Process Connections—Male Thread 1199-0000A07A 1199-057AB b dm G1 MLS, MMS, MFS and MRS Process Connection Dimensions Male Thread DIMENSIONS (mm) STANDARD DN PN b dm G1 DIN 11851 25 32 40 50 65 80 25 32 38 51 63,5 76 40 40 40 40 40 40 40 40 40 40 40 40 46 47 46 46 46 47 47 47 47 47 47 47 25 32 32 40 57 72 25 32 32 40 57 72 Rd52⫻1/6 Rd58⫻1/6 Rd65⫻1/6 Rd78⫻1/6 Rd95⫻1/6 Rd110⫻1/4 Rd40⫻1/6 Rd48⫻1/6 Rd60⫻1/6 Rd70⫻1/6 Rd85⫻1/6 Rd98⫻1/6 SMS IDF(1) RJT(1) (1) Consult the factory for dimensions. Pressure-332 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 TABLE 32. MLS Sanitary Seal: Dairy Process Connections—Male Thread Ordering Information(1) Code S Industry Standard Sanitary Code Process Connection Style MLS Male Thread per DIN 11851 Code Process Connection Size Pressure Rating(2) DN 40 DN 50 DN 80 DN 25 DN 32 DN 65 40 bar 40 bar 40 bar 40 bar 40 bar 40 bar F0 G0 J0 D0 E0 H0 Code Diaphragm Material LA00 316L SST Code 0 6 Z 2 Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Counterpiece (tank/pipe spud) and gasket (standard gasket material ethylene propylene) (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lea d time. (2) Maximum working pressure is dependent on the pressure rating of the connection. TABLE 33. MMS, MFS, and MRS Sanitary Seals: Dairy Process Connections—Male Thread Ordering Information(1) Code S Industry Standard Sanitary Code Process Connection Style MMS MFS MRS Male Thread per SMS Standard Male Thread per IDF Standard Male Thread per RJT Standard Code Process Connection Size 30 50 20 60 70 (11/2 in.) DN 38 DN 51 (2 in.) DN 25 DN 63.5 DN 76 Code Diaphragm Material and Wetted Parts LA00 316L SST Code Options (Multiple Selections) 0 6 Z 2 Pressure Rating(2) 40 bar 40 bar 40 bar 40 bar 40 bar None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Counterpiece (tank/pipe spud) and gasket (standard gasket material ethylene propylene) (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lea d time. (2) Maximum working pressure is dependent upon the pressure rating of the connection. Pressure-333 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 VCS Sanitary In-Line Diaphragm Seal— Tri-Clamp Process Connection Dimensional Drawing for VCS Sanitary In-Line Diaphragm Seal 1.5 (38,1) Od 3.54 (90,0) C20240A OD VCS Process Connection Dimensions Max. Working Pressure DN 40 bar 40 bar 40 bar 40 bar 40 bar 40 bar 1 in. 1 1/2 in. 2 in. 2 1/2 in. 3 in. 4 in. Dimensions (mm) Od OD A 22,1 34,8 47,5 60,20 72,9 97,4 50,5 50,5 64,0 77,4 90,9 119,1 60,5 60,5 73,2 85,9 98,6 126,5 TABLE 34. VCS Sanitary In-Line Diaphragm Seal Ordering Information(1) Code Industry Standard S Code Sanitary Process Connection Style VCS(2) Code(3) In Line Tri-Clamp Seal (Maximum Working Pressure: 40 bar) Process Connection Size 20 30 50 70 90 Code 1 in. 1½ in. 2 in. 3 in. 4 in. Diaphragm Material(4) LA00 0 Z 316L SST Options (Multiple Selections) None Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) (1) Consult a Rosemount representative for minimum calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) Gasket and clamp are furnished by the user. The maximum working pressure is dependent upon the pressure rating of the connection. (3) DIN Tri-Clamp dimensions available on request. (4) When ordering optional diaphragm materials, the standard housing material is 316L SST, unless otherwise noted. Pressure-334 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 SCS Sanitary Tri-Clamp® Diaphragm Seal 1199-0000A06A, 1199-077AB Dimensional Drawing for SCS Sanitary Tri-Clamp Diaphragm Seal dm DN D SCS Process Connection Dimensions Dimensions (mm) DN PN dM D 1½ in. 2 in. 2½ in. 3 in. 40 40 40 40 32 40 57 72 50,5 64 77,5 91 TABLE 35. SCS Sanitary Tri-Clamp Diaphragm Seal Ordering Information(1) Code S Code SCS(2) Code(3) 30 50 60 70 Code LA00 Code 0 6 Z B 2 Industry Standard Sanitary Process Connection Style Tri-Clamp Seal (maximum working pressure: 40 bar) Process Connection Size 1½ in. 2 in. 2½ in. 3 in. Diaphragm Material(4) 316L SST Options (Multiple Selections) None Electrolytical polishing of diaphragm material Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Extra Fill for Cold Temperature Applications Counterpiece (tank/pipe spud) and gasket (standard gasket material ethylene propylene) (1) Consult a Rosemount representative for minimum calibrated spans. Shaded areas indicate special orders, consult your Rosemount representative for availability, performance effects, and lead time. (2) Gasket and clamp furnished by user. The maximum working pressure is dependent upon the pressure rating of the connection. (3) DIN Tri-Clamp sizes available on request. (4) When ordering optional diaphragm materials, the standard housing material is 316L SST unless noted otherwise.pper Pressure-335 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 EES Sanitary Tank Spud: Extended Diaphragm Seal 1199-0000A03A, 1199-056AB Dimensional Drawing for EES Sanitary Tank Spud Type: Extended Diaphragm Seal G A B C D E F Dimensions (mm) DN PN A B C D E F G 50 80 40 40 72 89 73 98 76 102 82.3 107.2 125 160 165 200 25 25 Flanged Type Tank Spud F D AB G Dimensions (mm) DN A B C D E F G 50 80 25 25 15 15 76 103 82.5 108 125 160 165 200 22 22 C TABLE 36. EES Sanitary Tank Spud Type: Extended Diaphragm Seal Ordering Information(1) Code Industry Standard S Code Sanitary Process Connection Style EES Code Flanged Tank Spud Seal Type: Extended Diaphragm Seal (Supplied with ethylene propylene gasket) Process Connection SizeFlange Pressure Rating JG GG Code DN 80 40 bar DN 50 40 bar Diaphragm and Wetted Parts Material(2) LA LB Code 316L SST Hastelloy C-276 Extension Length(3) 10 Code 25 mm Options (Multiple Selections) 0 1 2 Z 5 8 B 6 7 None Viton O-ring Tank spud counterpiece to be welded on tank: includes Ethylene-Propylene O-ring, stainless steel bolts, and washers Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) 50 m Diaphragm Thickness (available in 316L SST or Hastelloy) 150 m Diaphragm Thickness (316L SST or Hastelloy C-276 Diaphragm Material Only) Extra Fill for Cold Temperature Applications Electrolytical Polishing of Diaphragm Material Blind Plug for Tank Spud Counterpiece (1) Shaded areas indicate special orders. Consult your Rosemount representative for availability, performance effects, and lead time. (2) When ordering optional diaphragm materials, the standard housing material is 316L SST unless noted otherwise. (3) Other extension lengths are available upon request. Pressure-336 1199-0000B14B Flanged Type Tank Spud Dimensions E Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Varivent® Compatible Connection dm D’ D 1199-1199_02A, 1199-1199003B Dimensional Drawing for Varivent Compatible Connection Varivent Compatible Process Connection Dimensions dm PN 52 mm 40 Dimensions (mm) D D’ 84 68 TABLE 37. Varivent Compatible Sanitary Seal Ordering Information(1) Code S Industry Standard Sanitary Code Process Connection Style SVS Off-line Varivent compatible (maximum working pressure: 40 bar) Code Process Connection Size V0 Varivent compatible standard connection only Code Diaphragm Material LA00 316L SST Code Options (Multiple Selections) 0 6 B Z 2 None Electrolytical polishing of diaphragm material Extra Fill for Cold Temperature Applications Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) Counterpiece and (Varivent Type U) Gasket (standard gasket material ethylene propylene) (1) Varivent is a registered trademark of Tuchenhagen Nederland B.V. Pressure-337 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 CHS Homogenizer Clamping Flange Type Dimensional Drawings for CHS Homogenizer Clamping Flange Type 93 30 7 13.5 33.5 60.5 95 TABLE 38. CHS Homogenizer Clamping Flange Type–Ordering Information(1) Code Process Connection Style NCHS Homogenizer Clamping Flange Code Process Connection Size C Code(2) R 23,5 mm Pressure Rating 600 bar Code Diaphragm and Wetted Parts Material(3) LA00 316L SST Code 0 5 V B Z Options (Multiple Selections) None 50 m Diaphragm Thickness (available in 316L SST or Hastelloy) Teflon Coated Diaphragm for nonstick purposes only (available with 316L SST and Hastelloy C–276 diaphragm only) Extra Fill for Cold Temperature Applications Material Traceability per EN10204 DIN 3.1.B (Requires selection of transmitter code Q8) (1) Shaded areas indicate special orders. Please consult your Rosemount representative for availability, performance effects, and lead time. (2) Minimum range is 100 bar. (3) When ordering special diaphragm materials, the standard housing material is 316L SST, unless noted otherwise. Pressure-338 1199-NCHSA01A, 23.5 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 General Information WHAT IS A DIAPHRAGM SEAL SYSTEM? A diaphragm seal system consists of a pressure transmitter, a diaphragm seal, a fill fluid, and either a direct-mount or capillary-style connection. During operation, the flexible diaphragm and fill fluid separate the pressure sensitive element of the transmitter from the process medium. The capillary tubing or direct mount flange connects the diaphragm to the transmitter. When process pressure is applied, the diaphragm transfers the measured pressure through the filled system and capillary tubing to the transmitter element. This transferred pressure displaces the sensing diaphragm in the pressure-sensitive element of the transmitter. The displacement is proportional to the process pressure and is electronically converted to an appropriate current, voltage, or digital HART (Highway Addressable Diaphragm Transducer) output signal. WHY USE DIAPHRAGM SEALS? Seal systems provide a reliable process pressure measurement and prevent the process medium from contacting the transmitter diaphragm. Transmitter/diaphragm seal systems should be considered when: • • The process temperature is outside of the normal operating ranges of the transmitter and cannot be brought into those limits with impulse piping. The process is corrosive and would require frequent transmitter replacement or unusual materials of construction. • The process contains suspended solids or is viscous and may plug the impulse piping. • The application requires the use of sanitary connections. • There is a need for easier cleaning of the process from the connections to avoid contamination between batches. • There is a need to replace wet legs to reduce maintenance on applications where the wet leg is not stable or often needs to be refilled. • There is a need to make density or interface measurements. • The process medium may freeze or solidify in the transmitter or impulse piping. SPECIAL ORDERS Many other special-order transmitter/diaphragm seal materials, configurations, and fill fluids are available that are not covered in this document. Contact your Rosemount representative or consult the factory for special order information. ADDITIONAL INFORMATION This product data sheet provides information on Rosemount transmitter/diaphragm seal systems. Model 1199 diaphragm seals can be assembled to Model 3051, 1151, and 2088 differential, gage, and absolute pressure transmitters, and liquid level transmitters. For additional information, refer to the following product data sheets: Model 3051S Series of Instrumentation PDS 00813-0100-4801 Model 3051 Smart Pressure Transmitter Family PDS 00813-0100-4001 Model 1151 Pressure Transmitters PDS 00813-0100-4360 Model 2088 Gage and Absolute Pressure Transmitter PDS 00813-0100-4690 PERFORMANCE CONSIDERATIONS Temperature Effects Temperature effect errors occur when the fill fluid expands or contracts with fluctuations in the process or ambient temperature, thus causing a change in the internal pressure of the transmitter/seal system. Two primary factors affect the temperature performance of a diaphragm seal system: the diaphragm stiffness and the characteristics of the fill fluid. Pressure-339 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 All fill fluids expand and contract with changes in temperature. The coefficient of thermal expansion defines the amount of change and is represented in cubic centimeters of expansion per cubic centimeter of fluid per degree Celsius (cc/cc/°C). The amount of expansion varies between fill fluids, as shown in Figure 2. Selecting a fill fluid with a smaller coefficient of thermal expansion will help minimize temperature error. Table 1 on page 282 provides the coefficients of thermal expansion for all available fill fluids. Diaphragm Stiffness Diaphragm stiffness is a critical parameter affecting temperature performance. As the fill fluid expands and contracts, due to temperature changes, a flexible diaphragm will exert less back pressure than a stiff diaphragm (for equal changes in fill volume). Back pressure causes a measurement error as it acts upon the sensing diaphragm of the transmitter. Therefore, the more flexible diaphragm seal can accommodate changes in fill volume and minimize errors resulting from temperature changes. A larger volume of fill fluid increases the potential for volume expansion. By minimizing the capillary length and inside diameter, fill volumes can be kept as low as possible to reduce temperature error. Diaphragm stiffness is affected by the diaphragm surface diameter, material of construction, thickness, and convolution pattern. Of these factors, the most significant is the diaphragm seal diameter. Each diaphragm has its own characteristic stiffness curve. Generally, smaller diameter diaphragms are more stiff than larger diameter diaphragms, and thus have stiffness curves that are less vertical. A more vertical stiffness curve helps to minimize the amount of pressure error that can occur when the fill fluid expands or contracts with temperature changes. Time Response Use of diaphragm seals increases the overall response time of transmitter/diaphragm seal systems. Time response varies with temperature, pressure, capillary length, inside diameter (ID), fill fluid, viscosity, and transmitter type. Capillary ID: A smaller capillary inside diameter (ID) creates more restrictions and slows down the pressure transport. The larger capillary ID provides a faster response time. Figure 1 shows that large-diameter diaphragms, which are less stiff, have smaller errors caused by changes in the fill fluid volume. This is a result of a more vertical stiffness curve. The small-diameter diaphragms have a less vertical stiffness curve, resulting in larger errors with changes in temperature. Fill Fluid Viscosity: Viscosity of the fill fluid is a measure of its fluidity and is temperature dependent. Choosing a less viscous fill fluid enhances time response, especially when using longer capillaries in colder conditions. Fill Fluid The expansion characteristics and the volume of the fill fluid affect seal performance. FIGURE 1. Diaphragm Stiffness Curves KEY: Fill Fluids Pressure-340 Expansion of Oil Fluids in 1.0 Meters of 1 mm ID Capillary with Increasing Temperature 1199-0051A 20°C increase 15°C increase 10 °C increase A change in the fill fluid volume causes a smaller error for the larger diameter diaphragm than for the smaller diameter diaphragm. 1199-0048A Error associated with small diameter Error 5 °C increase Volume Small diameter seal stiffness curve Low Temp. Silicone Oil Gen. Purpose Silicone Oil Inert Initial Volume @ 25 °C Large diameter seal stiffness curve Centimeters3 Error associated with large diameter FIGURE 2. Effect of Fill Fluid Expansion on Fill Volume Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Refer to Figure 3 for a summary of temperature effect and time response properties of various seal systems. In-line seal designs, diaphragm seal designs with diameters less than 50 mm and various other design configurations can result in significant temperature effect errors. Consult Instrument ToolKit or contact a Rosemount representative for a detailed performance evaluation of a specific diaphragm seal system configuration. Capillary Length: A longer capillary provides a greater distance for the pressure signal to travel, thus increasing the response time. Applications with large tanks and slow changes in level, may not be hindered by a longer response time. Yet, a small, narrow tank may be subject to measurement difficulties if the response time is too slow. Applications that change rather quickly, such as flow, also require faster response times. DIRECT MOUNT SEAL CONNECTION TYPES Summary Adding seals to a transmitter can affect overall system performance. Selecting the most appropriate diaphragm seals, capillaries, and fill fluid can minimize these effects, maximize assembly performance, and still meet or exceed process demands. Model 3051, 1151, and 2088 transmitters with the Model 1199 direct mount style seals are flange mounted directly to the vessel. They provide precise level and specific gravity measurements and are available in a wide variety of configurations. Consider the following when selecting a diaphragm seal system: • Use larger diameter diaphragms to minimize temperature effects. • Keep capillary length as short as possible to reduce temperature effects and response time. • Select larger ID capillaries to improve time response or select smaller ID capillaries to improve temperature performance. • Select fill fluid that is the least viscous and has the smallest coefficient of thermal expansion while satisfying the most extreme process conditions. The direct-mount connection is welded at the seal and the “L” bracket on Model 3051C transmitters and at the seal and the transmitter flange for Model 1151 and 2088 transmitters. Figure 4, 5, and 6 illustrate the various direct mount seal assembly configurations and weld locations. FIGURE 3. Summary of Temperature Effect and Time Response with Various Seal, Capillary, and Fill Fluid Combinations Time Response Temperature Effect 30 15 °C 30 °C 30 °C 20 1199-0139 15 °C Seconds mbar 25 15 1199-0138 10 5 Diaphrag m Diameter Fill Fluid 50 mm 80 mm 50 mm 60 mm 50 mm 80 mm 50 mm 80 mm General Purpose General Purpose General Purpose General Purpose General Purpose General Purpose Inert Inert 5m 5m 5m 3m 3m 3m 3m 1 mm 1 mm Capillary 5m Length Inside 1 mm Diameter 1 mm 2 mm 2 mm 1 mm 1 mm Diaphrag m Diameter Fill Fluid 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm General Purpose General Purpose General Purpose General Purpose General Purpose General Purpose Inert Inert 5m 5m 5m 3m 3m 3m 3m 1 mm 1 mm Capillary 5m Length Inside 1 mm Diameter 1 mm 2 mm 2 mm 1 mm 1 mm Pressure-341 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 Direct Mount Option Code Index FIGURE 4. Model 3051 Direct Mount Connection Type Weld 40 mm Model 3051T (Option Code S1) Direct Mount Connection One Seal Connection = Option Code 95 (L = 25 mm) One Seal Connection = Option Code A5 (L = 50 mm) FIGURE 5. Model 3051T Direct Mount Connection Type Connection X = 50 mm X = 100 mm One Seal (S1) Two Seals (S2) One Seal All-Welded (S0) B3 B4 D3 D4 B7 D7 Model 2088 (Option Code S1) Direct Mount Connection One Seal Connection = Option Code 95 (L = 25 mm) One Seal Connection = Option Code A5 (L = 50 mm) FIGURE 7. Model 2088 Direct Mount Connection Type 104mm Weld 98 Weld L 1199-3051C06B 182 mm Model 1151 (Option Code S1 or S2) Direct Mount Connection One or Two Seal Connection = Option Code 92 FIGURE 6. Model 1151 Direct Mount Connection Type 40 mm Pressure-342 1199-0517B Weld 118mm L 138mm 1199-2088C07C X All-Welded System (Option Code S0 or S9) 1199-0517A Low Capillary Side Model 3051C Direct-Mount Connections Standard (Option Code S1 or S2) Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 VACUUM APPLICATIONS There are three parameters to consider when selecting a transmitter/seal system for vacuum applications: fill fluid compatibility, configuration, and installation. For full vacuum applications, the Model 3051C All Welded System is available. This transmitter/seal system welds the following four connection points, as shown in Figure 8: 4. Capillary-to-transmitter flange connection 5. Module-to-capillary connection Fill Fluid Compatibility The fill fluid must be able to withstand the highest temperature and lowest process pressure conditions under which the transmitter will be operating. Therefore, the fill fluid must have a vapor pressure that is compatible with the most extreme process conditions. (Be sure to consider temperature and pressure conditions during start-up and system cleaning operations). Temperature limits of fill fluids, as shown in Table 6 on page 284, are stated for positive and vacuum pressure conditions. Figure 8 provides the vapor pressure curves for general purpose, high temperature, and sanitary fill fluids. Configuration Transmitter Connections For moderate to high vacuum applications, the Model 1151 transmitter is available with a vacuum resistant gasket, to ensure extra reliability. 6. Transmitter fill screw 7. 316 SST bolts on the module-to-flange connection Installation For vacuum applications, to ensure positive pressure at the transmitter, mount the transmitter so that it is level with, or below the lowest tap. Under the following conditions, the transmitter fill fluid may start to vaporize, at which point, the transmitter will cease to make appropriate readings: • The transmitter is mounted above the lower tap (causing a negative head effect) • The process pressure is less than the head pressure exerted by the fill fluid. • This puts the transmitter fill fluid under a vacuum, thereby degrading the maximum operating temperature If the operating temperature and vacuum pressure exceed the vapor pressure point of the transmitter fill fluid, the fill fluid is likely to vaporize. FIGURE 8. Fill Fluid Vapor Pressure Curves and Model 3051C All-Welded System 2 Vapor Phase 4 3 1199-3051B28A 1 FILL_VP_CURVE_A Liquid Phase Detail of Welded Cap Assembly Pressure-343 Product Data Sheet 00813-0201-4016, Rev EA Catalog 2002 – 2003 Model 1199 The Model 3051C Pressure Transmitter may be protected by one or more of the following U.S. Pat. No.: 4,370,890: 4,612,812; 4,791,352; 4,798,089; 4,818,994; 4,833,922; 4,866,435; 4,926,340; 4,988,990; 5,028,746. MEXICO PATENTADO NO. 154,961. May Depend on Model. Other U.S. and Foreign Patents Issued and Pending. The Model 1151 Pressure Transmitter may be protected by one or more of the following U.S. Pat. Nos.: 3,854,039; 3,975,719; 4,339,750; and Re. 30.603. May Depend on Model. Other U.S. and Foreign Patents Issued and Pending, Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. Instrument Toolkit is a trademark of Rosemount Inc. Hastelloy, Hastelloy B-2, Hastelloy C, Hastelloy C–4, and Hastelloy C–276 are registered trademarks of the Cabot Corp. Viton and Teflon are registered trademarks of E.I. duPont de Nemours & Co. Tri-Clamp is a registered trademark of Tri-Clover, Inc. of the Alfa-Laval Group. Monel, Inconel, and Incoloy are registered trademarks of International Nickel Co. Varivent is a registered trademark of Tuchenhagen Nederland B.V. All other marks are the property of their respective owners. Cover Photo: 1199-063AB Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 www.rosemount.com Fisher-Rosemount GmbH & Co Shipping address: Argelsrieder Feld 3 82234 Wessling Germany Tel 49 (8153) 9390 Fax 49 (8153) 939172 ¢00813-0201-4016?¤ © 2002 Rosemount Inc. All rights reserved. Fisher-Rosemount Singapore Pte Ltd. 1 Pandan Crescent Singapore 128461 Tel (65) 777-8211 Fax (65) 777-0947 AP.RMT-Specialist@emersonprocess.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Modify Date : 2002:05:17 14:18:47-04:00 Create Date : 1999:02:04 16:49:40Z Page Count : 64 Creation Date : 1999:02:04 16:49:40Z Mod Date : 2002:05:17 14:18:47-04:00 Producer : Acrobat Distiller 5.0 (Windows) Author : rebemin Metadata Date : 2002:05:17 14:18:47-04:00 Creator : rebemin Title : 4016_201_RevEA-2.fm Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools