4120EC PROGRAMMING FORM Prog

User Manual: 4120EC-prog

Open the PDF directly: View PDF PDF.
Page Count: 2

Download4120EC PROGRAMMING FORM 4120EC-prog
Open PDF In BrowserView PDF
4120EC PROGRAMMING FORM
DEFAULT VALUES, WHERE APPUCABLE, ARE SHOWN IN BRACKETS [ ]
●OO INSTALLER

●32

CODE

SUBSCRIBER

#
00-09; B-F

mmmm
●u1

❑

MASTER CODE

Y33

n(lrl

*O2

[ENTER&9,

RESPONSE

d

d

b
[011]

[019]

●34

ckl

’35

C&lb 6 dl ‘ones
*O5

[o171

[016]

[015]

’36

[Opq

●&#(or

3 & # (or C)

[010]

*4I

❑

’44

RESPONSE TYPES
05=
00. unusedZone

Trouble
C6 = 24-hour
07= 24-hour
08= 24-hour
09. Fire

●O8 N.O. or N.C. SENSOR
bflflbflflbfl
[1] [1] [1] [1]
O = N.O. Sensor Loop;
●O9
~

[1]

by dayl Alarm by night
Silant
Audible
Auxiliary

[1]

X15secsp3C-15)

~

’13

ALARM

SOUNDER

’14

ZONE 8 RESPONSE

❑

O = Slow, 1 = Fast

•1
●25
•1

EXIT DELAY
X15 S’CSW-15)

●27

TEST REPORT INTERVAL

•1

O = No report; 1 = 12 hrs.; 2 = 24 hrs.; 3 = 168 hrs.

’31

PABX CODE
-——

supervision

‘

[0]

DETECT COUNT

RING

[010]

FORMAT

ADEMCO LO SPEED; 1 = RADIONICS;

2 = ADEMCO EXPRESS

TRANSMISSION

FORMAT

ADEMCO LO SPEED; 1 = RADIONICS;

2 = ADEMCO EXPRESS

CHECKSUM

❑

VERIFY
[0]

4+2 ZONE FORMAT SELECTION
1 = 4+2

[0]

Format, O = 3+1/4+1

ALARM

●56

REPORT

0 = Standard, 1.

❑

Expanded

RESTORE REPORT
O. Standard,l

=Expanded

TROUBLE

REPORT

[1]

BYPASS REPORT

●58

O. Standard,

m

1 = Expanded

o= Standard, 1 = Expandad

[0]

●59

OPEN/CLOSE

•1

O. Standard,

REPORT

1 = Expanded

[1]

TOUCH-TONE

DIAL

Yes, O. Rotary

*6O

LOW BAT, AC LOSS&

•1

O = Standard,

●65

ALARM

[70]

—

l_!._l L_!_l””’S-F

TEST REPORT

t . Expended

REPORTING

CODES ASSIGNED

mmmmmmmm
;I)]
[$]

[0]

L!-ll_!_J

O=EOLR

l= Yes, O=No

[2]

[1]

=NoEOLR;

*49

•1
[0]

DISABLE DURESS IN ADEMCO EXPRESS FORMAT
l= Yes, O=No
[0]

l.

I

•1

•1
[0]

u

DISABLE USAGE OF EOLR SUPERV. ON ZONE 1

0.

’57

l= Yes, O=No

[Op]

SECONDARY

•1

NO FIRE TIME-OUT
[0]
l= Yes, O=No

•1

64

’48

●54

[0]

’30

1Is]

[0]

TIME

QUICK ARM

[1 [5]

[0]

TIME DURATION

●29

115]

TAMPER CODE

‘?5

*55

●21

[1 15]

PRIMARY TRANSMISSION

[013]

[0[2]

~9:

0.

LMp.

●1 O

ENTRY DELAY

115]

00= no ring detect 01-14 for ring counts of 1-1 4; 15 when telephone
answering machine is cwwted
to the same phone line.

[1]

1 = N.C. Sensor

[115]

PROGRAM

l--!-l

LOOP (ZONES 14)

[1]

00-09; A-F

[1 15]

m
multiple

alarms/per zone/per armed period.
2nd & 3rd locations: enter response types for keypad panics.

04 = Interior Follower

PHONE #

B)

1st location: 00 = one alarmfper zonelper armed period; 01.

01 = SE #1
02= Not US’d
03- Perimetar

CS lD#

[115]

[016]

[ol~

CS DOWNLOAD

mlmlmmnlmlnlnl
●4O

Alarms

PHONE #

Elclmlnclnclnnclcl”’

MULTIPLE ALARMS & RESPONSE TYPES
FOR KEYPAD PANICS

mmm
Multiple

SECONDARY

❑ lnclclnclclclclclclcl”

‘ones

[014]

[013]

PHONE #

❑ nclclnclclmclclclcw

[134]

( O&lo)

TYPE

PRIMARY

[;0]

Enter 01-1 5; 00 = no code

I

(NOTE:

[fo]

[0;:]

[~0]

Ho]

repordng

When reporting 4+2 format, 2nd digit is always zone number)

WWW.DIYALARMFORUM.COM

4120EC-PR

V3 9/93

●66

ALARM REPORTING

CODES ASSIGNED (CONT’D)
(01-15); 00=no

mmm
Duress

3&?# Panic
(or C)

*& #Panic
(or B)

[010]

[010]

[010]

channel reporting

See Note in ●65

NON-ALARM
(01-15)
(00 for no

●67

CODES
AC

LOSS

AC Loss 2nd Digit

code
reporting)

Trbl
Trbl Restr
Bypass
Bypass Restr
flstr code for Alrrn,

“68

I.--u

m

J

Close ml

r-i-1

Lo Bat

ml

L. Bat 2- fJigit

m
~
Ill
[

I

open~

~
m

m
Cance’
m
‘est

I

AC Loss, Lo Bat

Defaults for above are all 010

HEXADECIMAL
O = 10 (REPORT
O =00

TO NUMERIC ENTRY CONVERSION

CODES)

(SUBS ID, PABX OR CS ID)

1=01 , 2=02, 3 =03 , 4=04, 5=05, 6=06 , 7=07, 8=08, 9=09, 6=11, C=12, D=13, E=14 , F=l 5

●

To Enter Program Mode:

1
I ● To Set Standard

I

●

Defaults:

To Exit Program Mode:

a) Press [*] and [#] at the same time within 30 seconds after power is applied to the
control, or
b) Enter installer code+ [8]+ [0] + [0]. Enter first field address to begin programming
(e.g., ●O1).

*
3
I

Press ●96
Press *99 or ●98: *99 allows re-entry to the programming mode by installer code.
*98 prevents re-entry to programming mode by installer code.

I

2NDEMC0
A DIVISION OF PllllVAY

CORPORATION

WWW.DIYALARMFORUM.COM

4120EC-PR

V3 9/93



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 2
Page Mode                       : UseThumbs
Page Layout                     : SinglePage
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:be58b220-62ed-4591-b73f-f3b81a79f22a
Creation Date--Text             : Thursday, May 21, 1998 3:47:04 PM
Keywords                        : 
Producer                        : Acrobat PDFWriter 3.0 for Windows
Modify Date                     : 2007:12:21 18:13:33-05:00
Creator Tool                    : aqif010.tmp
Metadata Date                   : 2007:12:21 18:13:33-05:00
Document ID                     : uuid:8fbf900a-d7af-4b2a-9f6a-106a630f2f42
Format                          : application/pdf
Title                           :   4120EC PROGRAMMING FORM
Creator                         : ADEMCO
Description                     : 
Create Date                     : Thursday, May 21, 1998 3:47:04 PM
Author                          : ADEMCO
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu