BitStorm 4800 Express 4821 A1 Installation Guide A2 GN21 00
4821-A2-GN21-00 4821-A2-GN21-00
User Manual: 4821-A2-GN21-00
Open the PDF directly: View PDF .
Page Count: 54
Download | |
Open PDF In Browser | View PDF |
BitStorm™ 4800 Express Installation Guide Document No. 4821-A2-GN21-00 October 2003 Copyright © 2003 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773. Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes. Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual. Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative. — Within the U.S.A., call 1-800-870-2221 — Outside the U.S.A., call 1-727-530-2340 Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification. Trademarks ACCULINK, COMSPHERE, FrameSaver, Hotwire, MVL, NextEDGE, OpenLane, Performance Wizard are registered trademarks of Paradyne Corporation. BitStorm, EtherLoop, GrandVIEW, ReachDSL, StormPort, StormSystem, StormTracker, and TruePut are trademarks of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners. A October 2003 4821-A2-GN21-00 ! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug — a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter. Prior to installation, use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem. If a 3-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment. 3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 5. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel. 6. General purpose cables are described for use with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer. To reduce the risk of fire, use a UL Listed or CSA Certified, minimum 26 AWG (0.129 mm2) telecommunication cable. 7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. 8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products. 9. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: — — Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. — Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. — — Use caution when installing or modifying telephone lines. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. Do not use the telephone to report a gas leak in the vicinity of the leak. — 10. Input power to the ALARM interface (located on the front panel of the enclosure) must not exceed 30V rms or 60V dc. 11. The equipment is intended for installation in a max. 50° C ambient temperature, in an environment that is free of dust and dirt. 12. The power supply cord for countries other than North America is to be a minimum H05 V V-F type, min. 0.75 mm2, 2-conductor and earth ground terminated in an IEC 320 connector on one end, and a plug which is certified for use in the country of installation at the other end. 13. Do not physically stack the Model 4821 units more than eight (8) units high. Physical stability has not been evaluated for a stack higher than eight units, and a configuration higher than eight units might be unstable and prone to tipping over. Ensure that the four (4) rubber feet provided with the product have been installed on the bottom of each unit before stacking one atop another. 4821-A2-GN21-00 October 2003 B EMI Notices ! UNITED STATES – EMI NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation. ! CANADA – EMI NOTICE: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe A respecte toutes les exigences du réglement sur le matérial brouilleur du Canada. Notices to Users of the Canadian Telephone Network NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment. NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is labeled on the equipment and includes the effect of the POTS splitter. The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five. Notice to Users of the United States Telephone Network This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal Attachment (ACTA). On the bottom side of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. This equipment is intended to connect to the Public Switched Telephone Network through the Model 6051 POTS splitter using a Universal Service Order Code (USOC) type RJ21X jack. Refer to the Installation Instructions for details. The Ringer Equivalence Number (or REN) is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. The REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point. For example, 03 represents a REN of 0.3. C October 2003 4821-A2-GN21-00 If the BitStorm 4800 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with the BitStorm 4800, refer to the repair and warranty information on Page A. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. The user may make no repairs to the equipment. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. If the site has specially wired alarm equipment connected to the telephone line, ensure the installation of the BitStorm 4800 does not disable the alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. Supplier’s Declaration of Conformity Place of Issue: Paradyne Corporation 8545 126th Avenue North Largo, FL 33773-1502 USA Date of Issue: 3/28/2002 Paradyne Corporation, located at the above address, hereby certifies that the BitStorm 4800, Model Number 4821-AX-XXX, bearing labeling identification number US:AW2HN04B4821 complies with: the Federal Communications Commission’s (“FCC”) Rules and Regulations 47 CFR Part 68 and the Administrative Council on Terminal Attachments (“ACTA”)-adopted technical criteria TIA/EIA/IS-968, “Telecommunications – Telephone Terminal Equipment – Technical Requirements for Connection of Terminal Equipment To the Telephone Network, July 2001.” Patrick Murphy Senior Vice President, Chief Financial Officer CE Marking When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library → Technical Manuals → CE Declarations of Conformity. 4821-A2-GN21-00 October 2003 D Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. E October 2003 4821-A2-GN21-00 Contents About This Guide 1 2 Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Related Product Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Related Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Cables Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Unpacking the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Mounting Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Rack or Wall Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Shelf or Desktop Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Installing the Mounting Brackets for Rack Mounting . . . . . . . . . . . . . . 1-7 Installing the BitStorm 4800 Express Into a Rack . . . . . . . . . . . . . . . . 1-8 Installing the Mounting Brackets for Wall Mounting . . . . . . . . . . . . . . . 1-10 Installing the BitStorm 4800 Express on a Shelf or Desktop . . . . . . . . 1-12 Cabling Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 DSL Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Uplink Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Management Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Modem Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Alarm Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Grounding Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 Installation Cabling 4821-A2-GN21-00 4821-A2-GN21-00 i Contents 3 4 LEDs LED Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Front Panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 System LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Logging In to the BitStorm 4800 Express. . . . . . . . . . . . . . . . . . . . . . . 4-3 Setting the IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Configuration A Connectors, Cables, and Pin Assignments Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Management Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Uplink Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 DSL Network Interface Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4 Alarm Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5 Modem Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6 Console Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6 B Equipment List C Technical Specifications Index ii July 2002 4821-A2-GN20-10 About This Guide Document Purpose and Intended Audience This document is written for technicians who install the BitStorm 4800 Express IP DSLAM, Model 4821-A1-447. Document Summary Section Description Chapter 1, Installation Describes the physical installation of the BitStorm 4800 Express into a rack. Chapter 2, Cabling Describes how to install all cables for the BitStorm 4800 Express and Management Module. Chapter 3, LEDs Explains the meaning and usage of the front panel LEDs. Chapter 4, Configuration Describes the minimal configuration steps required to prepare the BitStorm 4800 Express for remote access. Appendix A, Connectors, Cables, and Pin Assignments Provides pinouts for all connectors on the BitStorm 4800 Express. Appendix B, Equipment List Provides part numbers for the BitStorm 4800 Express and related products. Appendix C, Technical Specifications Lists the technical characteristics of the BitStorm 4800 Express. Index Lists key terms, acronyms, concepts, and sections in alphabetical order. A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.paradyne.com. Select Library → Technical Manuals → Technical Glossary. 4821-A2-GN21-00 October 2003 iii About This Guide Related Product Documents Documentation for the BitStorm 4800 Express IP DSLAM is available on the World Wide Web at www.paradyne.com. Select Library → Technical Manuals→ BitStorm DSL Systems. Document Number Document Title 4800-A2-GB20 BitStorm 4800 User’s Guide Describes how to use the web interface, the command line interface (CLI), and Simple Network Management Protocol (SNMP) to configure BitStorm 4800 series DSLAMs. Lists and explains all CLI commands. 6051-A2-GZ40 BitStorm 6051 POTS Splitter Installation Instructions Describes how to install the POTS splitter card and chassis used with the BitStorm 4800 series DSLAMs in North America. To order a paper copy of a Paradyne document: Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396) Outside the U.S.A., call 1-727-530-8623 Related Specifications iv Document Number Document Title ANSI T1.413-1998 Network to Customer Installation Interfaces – Asymmetric Digital Subscriber Line (ADSL) Metallic Interface ANSI/EIA-310-D-1992 Cabinets, Racks, Panels, and Associated Equipment G.992.1 Asymmetrical digital subscriber line (ADSL) transceivers G.992.2 Splitterless asymmetric digital subscriber line (ADSL) transceivers IEEE 802.1D Media Access Control (MAC) Bridges IEEE 802.1Q Virtual Bridged Local Area Networks October 2003 4821-A2-GN21-00 Installation 1 Preparation Consider the following before installing the BitStorm™ 4800 Express IP DSLAM: Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. Installation Options The BitStorm 4800 Express may be: — Mounted with the included mounting brackets in a standard 19-inch (483 mm) or 23-inch (584 mm) rack, or, with separately purchased mounting brackets, in a 21-inch (535 mm) ETSI or 24-inch (610 mm) EIA rack. ETSI brackets are available from Paradyne. See Appendix B, Equipment List. As many BitStorm 4800 Express units may be mounted in a standard rack as there are 1.75-inch (44.45 mm) spaces in the rack, so long as adequate cooling is provided. — Mounted vertically against a wall. The standard mounting brackets provided can be fastened to the base of the unit for wall mounting. — Set on a shelf or desktop. Up to eight BitStorm 4800 Express units may be stacked on a shelf or desktop. Power The BitStorm 4800 operates from a standard AC power supply (90 to 264 VAC at 47 to 63 Hz). Other Cabling With the exception of the power cord, no cables are provided with the BitStorm 4800 Express. See Cables Required on page 1-2 to determine what cables you need to procure before installation. 4821-A2-GN21-00 October 2003 1-1 1. Installation Cables Required Table 1-1 shows all the cables that may be required for your installation. Table 1-1. Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 1–48 50-pin RJ21X Telco-type straight connector and 50-wire cable. Two cables required. Up to 24 DSL ports to Main Distribution Frame, punchdown block, or splitters. UPLINK 8-position modular plug and 8-wire Category 5 or better twisted pair cable. TheBitStorm 4800 Express to the Wide Area Network (WAN) via an Ethernet switch. MGMT 8-position modular plug and 8-wire Category 5 or better unshielded twisted pair (UTP) cable. The BitStorm 4800 Express to a Network Management System over a Local Area Network (LAN) employing 10BaseT or 100BaseT. CONSOLE DB9 plug connector and shielded cable. The other connector depends on the serial port on your terminal or PC, but normally is a DB9 socket. The Management Module to a terminal or a PC with a terminal emulation program. MODEM DB9 socket connector and shielded cable. The other connector depends on your modem, but normally is a DB25 plug. The Management Module to an external modem. The connector can also be used to connect a terminal or PC. ALARM 8-position modular plug and 8-wire cable. The Management Module to an alarm system. Unpacking the Hardware HANDLING PRECAUTIONS FOR ! STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative. The BitStorm 4800 Express is shipped in a cardboard shipping container. Carefully remove the unit from its shipping container and check for physical damage. If the unit shows signs of shipping damage, notify your sales representative. 1-2 October 2003 4821-A2-GN21-00 1. Installation Package Contents In addition to this installation guide, the BitStorm 4800 Express shipping carton should contain: BitStorm 4800 Express Mounting brackets (one left and one right) Power cord Hardware kit (see Table 1-2, Contents of Hardware Kit Shipped with the BitStorm 4800 Express) If anything is missing, notify your sales representative. Before installing the BitStorm 4800 Express, read the Important Safety Instructions in the beginning of this document. Be sure to register your warranty at www.paradyne.com/warranty. 4821-A2-GN21-00 October 2003 1-3 1. Installation Table 1-2. Contents of Hardware Kit Shipped with the BitStorm 4800 Express Appearance 1-4 Description Quantity Self-retaining nut for racks without threaded holes 5 Dress screw (12-24 x 1/2 inch) for use with self-retaining nuts 5 Machine screw with captive starwasher (10-32 x 1/2 inch) for use with racks with threaded holes 5 Flat-head screw (8-32 x 1/4 inch) for attaching mounting brackets to unit 7 Jackscrew for attaching Telco connectors with short mounting screws 2 Rubber foot for desk-mount and stacking of units 4 Cable tie (8-inch) for strain relief and cable management 3 October 2003 4821-A2-GN21-00 1. Installation Mounting Configurations Three basic installation configurations are available: Rack mount Wall mount Shelf or desktop Rack or Wall Mount Installation The BitStorm 4800 Express is shipped with mounting brackets suitable for a 19-inch (483 mm) or 23-inch (584 mm) rack. The same brackets may be used to attach the unit to a wall. Brackets suitable for a 21-inch (535 mm) ETSI rack are available from Paradyne (see Appendix B, Equipment List), and brackets suitable for a 24-inch (610 mm) rack can be obtained from other sources. NOTE: In this guide, the term rack refers to any rack, cabinet, frame, or bay suitable for mounting telecommunications equipment. Shelf or Desktop Installation The BitStorm 4800 Express may also be placed on a shelf or desktop. If you will not mount the BitStorm 4800 Express in a rack or on a wall, proceed to Installing the BitStorm 4800 Express on a Shelf or Desktop on page 1-12. 4821-A2-GN21-00 October 2003 1-5 1. Installation Mounting Brackets The right-angle mounting brackets have a long side and a short side. For 19-inch (483 mm) racks, the long side of a supplied bracket is fastened to the side of the unit. For 23-inch (584 mm) racks, the short side of a supplied bracket is fastened to the side of the unit. For wall mounting, the long side of a supplied bracket is fastened to the bottom of the unit. The optional ETSI brackets are always installed with the short side fastened to the BitStorm 4800 Express. Both the supplied brackets and the optional ETSI brackets are marked LEFT SIDE and RIGHT SIDE, with reference to the left and right sides of the BitStorm 4800 Express when viewed from the front. For wall mounting, proceed to Installing the Mounting Brackets for Wall Mounting on page 1-10. For rack mounting, proceed to Installing the BitStorm 4800 Express Into a Rack on page 1-8. 1-6 October 2003 4821-A2-GN21-00 1. Installation Installing the Mounting Brackets for Rack Mounting Procedure To install the mounting brackets for rack mounting: 1. Identify the flat-head screws provided in the hardware kit. Six screws are required for the 19-inch (483 mm) configuration, and four screws for the other configurations. 2. Attach the brackets appropriate to your rack size. Tighten all screws firmly. 19-inch (483 mm) Rack Mount with Supplied Brackets 21.1-inch (535 mm) Rack Mount with Optional ETSI Brackets 4821-A2-GN21-00 October 2003 23-inch (584 mm) Rack Mount with Supplied Brackets 02-17067 1-7 1. Installation Installing the BitStorm 4800 Express Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes Procedure To install the BitStorm 4800 Express into a rack: 1. Determine where in the rack you will mount the BitStorm 4800 Express. If your rack does not have threaded screw holes, slip self-retaining nuts onto the rails where the BitStorm 4800 Express will be fastened. 02-17070 1-8 October 2003 4821-A2-GN21-00 1. Installation 2. Place the BitStorm 4800 Express so that the brackets rest against the front of the rails. Insert screws in the bottom screw positions and hand-tighten them. 3. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. ALARM OK ALARM TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MODE M 23 24 25 26 27 28 CONSOL E 29 30 MGMT 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 UPLIN K 10/100 47 48 ALARM MODEM 4804 OK ALARM TEST CONSOLE 1 2 15 16 17 18 MGMT 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 UPLINK GigE 4821 4 5 6 7 8 03-17468 4. Do not plug in the unit. Proceed to Chapter 2, Cabling. 4821-A2-GN21-00 October 2003 1-9 1. Installation Installing the Mounting Brackets for Wall Mounting Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 0.25-inch (6 mm) diameter screws in 0.75-inch (19 mm) plywood. Procedure To install the mounting brackets for wall mounting: 1. Identify the flat-head screws provided in the hardware kit. Two screws are required for each bracket. 2. Orient the unit so that the bottom is facing you and the faceplate is at the top. 3. Locate the supplied Right Side mounting bracket and fasten it to the right side of the unit. 03-17469 4. Locate the supplied Left Side mounting bracket and fasten it to the left side of the unit. 5. Tighten all screws firmly. 1-10 October 2003 4821-A2-GN21-00 1. Installation 6. Install two wood screws (not provided) at the same height at least 30 inches (760 mm) above the floor and 17.85 inches (453 mm) apart. Do not completely tighten the screws. Leave them so their heads are about 0.25 inch (6 mm) from the wall. 17.85 in (453 mm) 03-17470 7. Hang the unit from the wood screws to verify that the screws are properly placed. The screws should freely slide into the top of the key slots in the brackets. 8. Do not fasten the unit to the wall until it is completely cabled and tested. Proceed to Chapter 2, Cabling. 4821-A2-GN21-00 October 2003 1-11 1. Installation Installing the BitStorm 4800 Express on a Shelf or Desktop If the BitStorm 4800 Express will be placed on a shelf or desktop, install the provided rubber feet before putting the BitStorm 4800 Express in position. Procedure To install the BitStorm 4800 Express on a shelf or desktop, as a standalone unit or in a stack: 1. Locate the rubber feet in the hardware kit provided with the BitStorm 4800 Express. 2. Turn the BitStorm 4800 Express upside down on a work surface. Squares stamped into the bottom of the BitStorm 4800 Express show the proper positions for the feet. 3. Remove the protective sheet from the bottom of each foot, then press the foot onto a corner of the bottom of the BitStorm 4800 Express. -48 RTS 25 DSL PO 4 RTS 1-2 DSL PO 02-17072 4. Turn the BitStorm 4800 Express right side up and place it in position on a shelf or desktop. If the installation includes more than one unit, one can be stacked atop another. Up to eight units can be stacked together. 5. Do not plug in the unit. Proceed to Chapter 2, Cabling. 1-12 October 2003 4821-A2-GN21-00 Cabling 2 Cabling Overview The BitStorm 4800 Express has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required: 4821-A2-GN21-00 DSL Ports on page 2-2 Uplink Port on page 2-4 Management Port on page 2-5 Console Port on page 2-6 Modem Port on page 2-7 Alarm Port on page 2-8 Grounding Lug on page 2-9 Power Cord on page 2-10 October 2003 2-1 2. Cabling DSL Ports The BitStorm 4800 Express has two DSL connectors. Each connector supports the tip and ring connections of up to 24 DSL ports over a 50-position cable. These must be connected to a POTS (plain old telephone service) splitter. In North America, the BitStorm 6051 POTS Splitter must be used. (See the BitStorm 6051 POTS Splitter Installation Instructions for information.) Elsewhere the splitter must conform to all regional regulatory requirements. Procedure To cable the DSL Ports: 1. Insert a cable tie (provided) through the top of the anchor mount next to the DSL PORTS 1–24 connector. 2. If the connector for your cable has a long captive screw, attach it to the DSL PORTS 1–24 connector and fasten it with the captive screw. Anchor Mount Long Screw 50-Pin Connector 02-17082 3. If the connector for your cable has a short captive screw, install the provided jack screw in the threaded hole next to the DSL PORTS 1–24 connector. Attach the cable to the DSL PORTS 1–24 connector and fasten it to the jack screw with its short captive screw. #4-40 Jack Screw Anchor Mount Short Screw 50-Pin Connector 2-2 October 2003 02-17083 4821-A2-GN21-00 2. Cabling 4. Tighten the cable tie around the connector and trim the excess. 02-17084 5. If ports 25–48 are used, repeat Step 1 through Step 4, substituting DSL PORTS 25–48 for DSL PORTS 1–24. 6. Connect the tip and ring connections to a POTS splitter. See the documentation that came with your POTS splitter for more information. 7. Secure the cables as required for strain relief. TS 25-4 DSL POR POTS Splitter Card in 1-Slot Chassis 8 TS 1-24 DSL POR BitStorm 4800 Rear UPLINK 10/100 Front 03-17471 4821-A2-GN21-00 October 2003 2-3 2. Cabling Uplink Port The Uplink port is used to connect the BitStorm 4800 Express to a WAN through your Ethernet switch. Either a straight-through or a crossover cable can be used. The wiring is automatically detected and, if necessary, compensated for. Procedure To use the Uplink port: 1. Connect a modular 8-pin cable to the UPLINK 10/100 port. 2. If the BitStorm 4800 Express is in a rack, fasten the cable to a rail with a cable tie. 3. Connect the other end of the cable to your Ethernet switch. MGMT UPLIN K 10/100 8-Position Modular Plug 2-4 October 2003 03-17472 4821-A2-GN21-00 2. Cabling Management Port The MGMT (management) port can be used to connect the BitStorm 4800 Express to a network management system using a 10BaseT or 100BaseT LAN. The MGMT port is isolated and no user data is accessible over it. Either a straight-through or a crossover cable can be used. The wiring is automatically detected and, if necessary, compensated for. Procedure To use the MGMT port: 1. Connect a modular 8-pin cable to the MGMT port. 2. If the BitStorm 4800 Express is in a rack, fasten the cable to a rail with a cable tie. 3. Connect the other end of the cable to your Ethernet hub or to a network interface card in a PC. Hub Device ALARM OK ALARM TEST 1 2 3 4 5 6 MODEM CONSOL E 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MGMT 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 03-17473 4821-A2-GN21-00 October 2003 2-5 2. Cabling Console Port The CONSOLE port on the Management Module normally serves as the primary user interface with the BitStorm 4800 Express during installation. Procedure To connect a terminal or PC to the CONSOLE port: 1. Configure the terminal or terminal emulation program to use the following parameters: — Maximum speed: 9600 bps — Data bits: 8 — Parity: None — Stop bits: 1 — Flow Control: None 2. Determine and procure the proper Data Terminal Equipment (DTE) cable type. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial port on your terminal or PC. 3. Connect the DB9 plug connector to the CONSOLE port socket. The CONSOLE port is ordinarily used only during installation, so do not fasten the connector. 4. Connect the other end of the cable to the serial port of your terminal or PC. Serial Port ALARM OK ALARM TEST 1 2 3 4 5 6 MODEM CONSOL E 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MGMT 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 03-17474 2-6 October 2003 4821-A2-GN21-00 2. Cabling Modem Port The MODEM port on the Management Module can be used to attach a modem for remote dial-in management of the BitStorm 4800 Express. The MODEM port can also be used to attach a terminal or PC to the Management Module using a Data Communications Equipment (DCE) cable. Procedure To connect a modem to the MODEM port: 1. Determine and procure the proper DCE cable type. The MODEM port requires a DB9 socket connector. The other connector depends on the serial port on your modem, but normally a DB25 plug is required. 2. Connect the DB9 socket connector to the MODEM port socket. 3. If the modem will be permanently connected, fasten the connector to the Management Module with its captive screws. If the BitStorm 4800 Express is in a rack, dress the cable to the left and attach it to the rail with a cable tie. 4. Connect the other end of the cable to the serial port of your modem. Serial Port Modem PWR ALM TST LINE ETHER NET ALARM OK ALARM TEST 1 2 3 4 5 6 MODEM CONSOL E 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MGMT 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 03-17475 4821-A2-GN21-00 October 2003 2-7 2. Cabling Alarm Port The ALARM port provides a normally-on circuit and a normally-off circuit that reverse their states in response to an alarm. This interface can be used to set off a physical alarm. Procedure To use the ALARM port: 1. Connect a modular 8-pin cable to the ALARM port. 2. If the BitStorm 4800 Express is in a rack, dress the cable to the left and secure it to the rail with a cable tie. 3. Connect the other end of the cable to your alarm monitoring system. CO Alarm Monitoring System ALARM OK ALARM TEST 1 2 3 4 5 6 MODEM CONSOL E 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MGMT 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 03-17476 2-8 October 2003 4821-A2-GN21-00 2. Cabling Grounding Lug Procedure To connect the unit to a ground: 1. Strip back the insulation approximately 5/16 in (8 mm) on 14 AWG (2.08 mm2) copper ground wire. 2. Loosen the screw on the grounding lug located on the back panel next to the power switch. 3. Insert the stripped end of the wire through the bottom of the grounding lug and tighten the screw. Ensure that the screw makes contact with the stripped portion of the wire. 4. Attach the ground wire to an earth ground. -48 RTS 25 DSL PO 4 RTS 1-2 DSL PO To Ground 02-17081 4821-A2-GN21-00 October 2003 2-9 2. Cabling Power Cord The BitStorm 4800 Express can be powered by any AC source providing 90 to 264 VAC at 47 to 63 Hz. Procedure To connect the BitStorm 4800 Express to a power source: 1. Verify that the switch on the rear panel is in the Off (0) position. 2. Insert the power cord into the socket under the switch. 3. If the BitStorm 4800 Express is in a rack, dress the power cord to the left and fasten it to the rail with a cable tie. 4. Connect the other end of the power cord to a grounded AC power source. 5. Press the On (1) position of the switch to turn on the BitStorm 4800 Express. 4 RTS 1-2 DSL PO 02-17080 When power is applied to the BitStorm 4800 Express, the front panel Light-Emitting Diodes (LEDs) convey the state of the unit and its interfaces. See Chapter 3, LEDs. 2-10 October 2003 4821-A2-GN21-00 LEDs 3 LED Locations The small black-on-white rectangles in the following illustration denote the locations of the front panel LEDs. ALARM 4804 OK ALARM TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MODEM 23 24 25 26 27 28 29 30 CONSOL 31 32 35 36 37 38 ALARM OK ALARM TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 E MGMT 33 34 39 40 41 42 43 44 45 46 UPLINK 10/100 47 48 MODEM 23 24 25 26 27 28 CONSOLE 29 30 31 32 33 34 35 36 37 38 MGMT 39 40 41 42 43 44 45 46 UPLINK 10/100 47 48 03-17466 Figure 3-1. 4821-A2-GN21-00 Front Panel LEDs October 2003 3-1 3. LEDs Front Panel LEDs When power is first applied to the BitStorm 4800 Express it performs a self-test. When this test is successfully completed, the OK LED lights. The meaning of all the LEDs is as shown in Table 3-1, Front Panel LEDs. Table 3-1. LED Color State Meaning ALARM Amber Off No Alarms. On Unit failed self-test, the Uplink port is down, the unit has exceeded a safe temperature, or a fan has failed. Off The port is disabled or no signal is detected on the line. On Port has successfully trained with the remote and is active. Blinking Port is attempting to train. Off The port is disabled, or no physical connection exists. On A physical connection is detected. Off No power, or the unit has not completed initialization. On Unit has power and has completed initialization. Off Normal operating mode. On At least one port is in test mode. Off The port is disabled, or no physical connection exists. On A physical connection is detected. DSL Port (1–48) MGMT OK TEST UPLINK 3-2 Front Panel LEDs Green Green Green Amber Green October 2003 4821-A2-GN21-00 3. LEDs System LEDs The three system LEDs, OK, TEST, and ALARM, have meaning at all times, as shown in Table 3-2, System LEDs. Table 3-2. 4821-A2-GN21-00 System LEDs OK ALARM TEST Description Off Off Off Unit is powered Off. Off Off ON Unit Failed – LEDs should never be in this state. Notify your service representative. Off ON Off Unit Failed – The unit has power, but never completed its initialization process. Notify your service representative. Off ON ON Self-Test – The LEDs should be in this state only during self-test, immediately after the unit is turned on. ON Off Off Normal Operation – Unit has successfully passed self-test, there are no alarms in the system, and none of the ports is in test mode. ON Off ON Test Mode – At least one port is in test mode. ON ON Off Alarm – Unit has failed self-test, the Uplink port is down, or a major alarm condition exists. Verify that the Uplink port is properly connected. If necessary, notify your service representative. ON ON ON Alarm – At least one port is in test mode, and a major alarm condition exists. Notify your service representative. October 2003 3-3 3. LEDs 3-4 October 2003 4821-A2-GN21-00 Configuration 4 Overview The BitStorm 4800 Express is designed to require minimal configuration before it can be accessed by a Network Operations Center (NOC). You may need to configure: The IP address for the Management Module if the default address (10.10.10.10) is not usable The default gateway address Initial configuration can be performed using the Command Line Interface (CLI). The CLI is available from a terminal or PC connected to the CONSOLE port of the Management Module. See the BitStorm 4800 User’s Guide for detailed information about the CLI. Conventions Used In this book, the Enter key means whatever key you use to submit data to your terminal or PC. It may be called the Return key on older devices. Characters displayed on your screen, including those you type, are shown in the Courier font in this book. 4821-A2-GN21-00 October 2003 4-1 4. Configuration Using the CLI You need to type only enough of a command to make it unique. For example, if you enter: sh man i the CLI interprets it as: show management ip You can prompt expansion of a command or parameter by pressing the Tab key. For example, if you enter: sh man then press the Tab key, the CLI responds: sh management You may then proceed with typing the rest of the command. You can obtain help with CLI commands by typing a ? (question mark). A question mark alone lists all commands. A command followed by a question mark lists all usages of the command. For example, if you enter: sh ? the CLI lists all the possible show commands. 4-2 October 2003 4821-A2-GN21-00 4. Configuration Logging In to the BitStorm 4800 Express When the BitStorm 4800 Express is turned on, the following prompt is displayed on the terminal: Login> Procedure To log in to the BitStorm 4800 Express: 1. Type admin at the login prompt and press Enter. The following prompt is displayed: Password> 2. The default user password is null, so simply press Enter. The following prompt is displayed: IAC> IAC stands for IP Access Concentrator. 3. Type privilege and press Enter to enter administrator mode. The following prompt is displayed: Password> 4. The default administrator password is null, so simply press Enter. The following prompt is displayed: IAC# This shows that you are in administrator mode. 4821-A2-GN21-00 October 2003 4-3 4. Configuration Setting the IP Address The IP address of the Management Module must be set before the BitStorm 4800 Express can be remotely managed. Procedure To set the IP address of the Management Module: 1. At the IAC# prompt, type: configure management address address mask gateway Where: — address is the IP address to be assigned to the Management Module — mask is the IP subnet mask for the specified address — gateway is the default gateway IP address For example: conf man addr 135.26.10.37 255.255.255.0 135.26.10.254 2. Press Enter. The prompt changes to IAC#! to show that the configuration change has yet to be saved. 3. Type save and press Enter. 4. To verify that the address has been set, type: show management ip The CLI displays the IP address, subnet mask, and default gateway address. 4-4 October 2003 4821-A2-GN21-00 Connectors, Cables, and Pin Assignments A Overview The following sections provide pin assignments for: Management Port Connector on page A-2 Uplink Connector on page A-3 DSL Network Interface Cable on page A-4 Alarm Port on page A-5 Modem Port Connector on page A-6 Console Port Connector on page A-6 ALARM 4804 OK ALARM TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MODE 23 24 25 26 27 28 M 29 30 CONSOL E MGMT 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 UPLIN K 10/100 47 48 03-17467 Figure A-1. BitStorm 4800 Express Front Panel DSL PORTS 1-24 DSL PORTS 25-48 02-17066-01 Figure A-2. 4821-A2-GN21-00 BitStorm 4800 Express Rear Panel October 2003 A-1 A. Connectors, Cables, and Pin Assignments Management Port Connector The Management (MGMT) connector is an 8-pin unkeyed modular jack for a 10/100BaseT management interface. Either a straight-through or a crossover cable can be used. The wiring is automatically detected and, if necessary, compensated for. Table A-1. A-2 Management Port Pinouts Signal Pin Transmitted Data + 1 Transmitted Data – 2 Received Data + 3 Unused 4 Unused 5 Received Data – 6 Unused 7 Unused 8 October 2003 Pin 1 Pin 8 97-15449 4821-A2-GN21-00 A. Connectors, Cables, and Pin Assignments Uplink Connector The UPLINK wire connector is an 8-pin unkeyed modular jack for 10/100BaseT. Either a straight-through or a crossover cable can be used. The wiring is automatically detected and, if necessary, compensated for. Table A-2. 4821-A2-GN21-00 Uplink Port Pinouts Signal Pin Transmitted Data + 1 Transmitted Data – 2 Received Data + 3 Unused 4 Unused 5 Received Data – 6 Unused 7 Unused 8 October 2003 Pin 1 Pin 8 97-15449 A-3 A. Connectors, Cables, and Pin Assignments DSL Network Interface Cable The BitStorm 4800 Express has two 50-pin RJ21X (designated CA21A in Canada) Telco connectors on its rear panel. The connectors provide the 2-wire loop interface from each DSL port to the demarcation point. Table A-3, DSL Connector Pinouts, lists the pin assignments for each of these interfaces. Note that Pins 25 and 50 are not used. Table A-3. DSL Connector Pinouts 1 A-4 DSL Port Connector Pins (Ring, Tip) 1 1, 26 2 2, 27 3 3, 28 4 4, 29 5 5, 30 6 6, 31 7 7, 32 8 8, 33 9 9, 34 10 10, 35 11 11, 36 12 12, 37 13 13, 38 14 14, 39 15 15, 40 16 16, 41 17 17, 42 18 18, 43 19 19, 44 20 20, 45 21 21, 46 22 22, 47 23 23, 48 24 24, 49 October 2003 25 50 26 02-17151 4821-A2-GN21-00 A. Connectors, Cables, and Pin Assignments Alarm Port The alarm relay reports major alarms through the ALARM port on the faceplate of the Management Module. The ALARM port is an 8-pin modular connector; only Pins 2, 3, and 4 may be used. Maximum ratings for the ALARM connector are: 30 VAC 60 VDC 0.5 A Table A-4. Alarm Connector Pinouts Signal Pin None 1 Closed on Alarm (Normally Open) 2 Common 3 Open on Alarm (Normally Closed) 4 4821-A2-GN21-00 None 5 Future Use 6 Future Use 7 None 8 October 2003 A-5 A. Connectors, Cables, and Pin Assignments Modem Port Connector The MODEM port connector is a DB9 female connector on the faceplate of the Management Module. It supports an EIA-232 circuit as shown in Table A-5, Modem Port Connector. Table A-5. Modem Port Connector Signal Direction Pin — — 1 Receive Data In 2 Transmit Data Out 3 DCE Data Terminal Ready Out 4 Ground — 5 Data Set Ready In 6 — — 7 — — 8 — — 9 Console Port Connector The CONSOLE port connector is a DB9 male connector on the faceplate of the Management Module. It supports an EIA-232 circuit as shown in Table A-6, Console Port Connector. Table A-6. A-6 Console Port Connector Signal Direction Pin — — 1 Transmit Data Out 2 ReceiveData In 3 — — 4 Ground — 5 — — 6 — — 7 — — 8 — — 9 October 2003 4821-A2-GN21-00 Equipment List B Table B-1. Equipment List Description Model Number Allied Data ADSL Modem – 10BaseT Ethernet and USB port CJ810 BitStorm 4800 Express 4821-A1-447 Includes BitStorm 4800 Express, mounting brackets and hardware, and Installation Guide. 4821-A2-GN21-00 BitStorm 4800 User’s Guide (paper copy) 4800-A2-GB20 BitStorm 6051 POTS Splitter 6051-B1-001 Filter 66-Block 05-00021-01 Hospitality VBN Server 01-00159-01 In-Line Phone Filter for ADSL 05-00015-01 Mounting Brackets for ETSI 21-inch (535 mm) Rack 4800-F1-011 October 2003 B-1 B. Equipment List B-2 October 2003 4821-A2-GN21-00 Technical Specifications C Technical specifications are subject to change without notice. Table C-1. Technical Specifications (1 of 2) Specifications Criteria Cooling and Air Handling Each BitStorm 4800 Express is independently cooled with integral fans and does not rely on vertical air flow. Electrical Safety All interfaces are Safety Extra-Low Voltage (SELV) circuits except: DSL ports Power supply These are designed in accordance with IEC 60950. Electromagnetic Meets the following standards: Compatibility CISPR 22, Class A (EMC) EN 50082-1 Network Approvals DSL Compatibility Installation Options FCC Part 15, Class A VCCI Class A FCC Part 68 Industry Canada CS-03 The BitStorm 4800 Express supports: G.dmt (G.992.1) G.lite (G.992.2) ANSI T1.413-1998 The Bitstorm 4800 Express can be: 4821-A2-GN21-00 EN 55022 Installed on a desktop and stacked up to eight units high Mounted with the included mounting brackets in a standard 19-inch (483 mm) or 23-inch (584 mm) rack, or, with separately purchased mounting brackets, in a 21-inch (535 mm) or 24-inch (610 mm) rack Attached vertically to a wall October 2003 C-1 C. Technical Specifications Table C-1. Technical Specifications (2 of 2) Specifications Criteria Interfaces DSL PORTS (one for 24-port models, two for 48-port models): 50-pin RJ21X Telco-type connector UPLINK: 8-pin modular jack (10/100BaseT) MGMT: 8-pin modular jack (10/100BaseT) CONSOLE: DB9 socket, EIA-232 MODEM: DB9 plug, EIA-232 ALARM: 8-pin modular jack Operating Environment Ambient Temperature: 0° to 50° C (32° to 122° F) Relative Humidity: 5% to 95% noncondensing Storage Temperature: –40° to 70° C (–40° to 158° F) Shock and vibration tolerance sufficient to withstand normal shipping Physical Dimensions Height: Width: Depth: Weight: Power 90 to 264 VAC at 47 to 63 Hz Power Consumption 100 VAC, 1.0A: 95W maximum 1.72 in (44.0 mm, or 1U as defined in EIA-310-C) without feet 17.32 in (440.0 mm) without mounting brackets 16.13 in (409.7 mm) 8.5 lb (3.85 kg) 120 VAC, 0.8A: 95W maximum 240 VAC, 0.5A: 95W maximum C-2 October 2003 4821-A2-GN21-00 Index Numerics D 10/100BaseT MGMT port pin assignments, A-2 Uplink pin assignments, A-3 50-pin connectors, A-4 default gateway, 4-4 password, 4-3 desktop installation, 1-12 dimensions, C-2 document purpose, iii documents, related, iii DSL PORTS cabling, 2-2 description, 1-2 pin assignments, A-4 A administrator login, 4-3 mode, 4-3 ALARM port cabling, 2-8 description, 1-2 pin assignments, A-5 audience for this document, iii B brackets, installation for rack mount, 1-7 C cables, A-1 DSL PORTS, A-4 MGMT port, A-2 required, 1-2 Uplink, A-3 cabling DSL ports, 2-2 POTS splitter, 2-2 Uplink, 2-4 CO alarm system, 2-8 CO ground lug, 2-9 Command Line Interface (CLI) help command, 4-2 using, 4-2 configuration, 4-1 mounting brackets, 1-5 connectors, A-1 front panel, A-1 rear panel, A-4 CONSOLE port cabling and settings, 2-6 description, 1-2 pin assignments, A-6 cooling and air handling, C-1 4821-A2-GN21-00 E earth ground, 2-9 electrical safety, C-1 Electromagnetic Compatibility (EMC), C-1 Enter key, 4-1 environment, C-2 equipment list package contents, 1-3 part numbers, B-1 F fasteners provided, 1-4 feature numbers, B-1 feet, 1-12 front panel (illustration), A-1 front panel LEDs, 3-2 G gateway, 4-4 glossary URL, iii grounding lug, 2-9 H hardware kit contents, 1-4 I IAC, 4-3 installation options, 1-1 October 2003 IN-1 Index installing feet for shelf installation, 1-12 in rack, 1-8 mounting brackets for rack mount, 1-7 mounting brackets for wall mount, 1-10 on shelf or desktop, 1-12 screws for wall mount, 1-11 self-retaining nuts, 1-8 unit into rack, 1-8 unit on wall, 1-10 interfaces, C-2 IP address, Management Module, 4-4 L LEDs, 3-1 descriptions, 3-2 system, 3-1 login, 4-3 lug for grounding, 2-9 M Management Module IP address, 4-4 MGMT port cabling, 2-5 description, 1-2 pin assignments, A-2 MODEM port cabling, 2-7 description, 1-2 pin assignments, A-6 mounting brackets description, 1-6 positioning, 1-6 mounting configurations, 1-5 power, C-2 connecting cord, 2-10 consumption, C-2 requirements, C-2 switch, 2-10 preinstallation, 1-1 preparation, 1-1 product-related documents, iv purpose of this document, iii R rack installation, 1-8 bracket installation, 1-7 example, 1-9 procedure, 1-8 rear panel (illustration), A-1 related documents, iv related specifications, iii requirements, 1-1 Return key, 4-1 S save command, 4-4 screws provided, 1-4 shelf installation, 1-12 shipping carton, 1-3 show management ip, 4-4 site preparation, 1-1 requirements, 1-1, C-2 specifications, iii subnet mask, 4-4 synopsis of chapters, iii system LEDs, 3-1 O T operating environment, C-2 optional mounting brackets, 1-5 order numbers, B-1 overview configuration, 4-1 of book, iii technical specifications, C-1 Telco connectors fastening, 2-2 pin assignments, A-4 terminal cabling and settings, 2-6 troubleshooting using LEDs, 3-1–3-2 typographic conventions, 4-1 P package contents, 1-3 part numbers, B-1 password, 4-3 PC cabling and settings, 2-6 physical dimensions, C-2 pin assignments, A-1 ALARM port, A-5 POTS splitter, 2-2 IN-2 U unpacking, 1-2 Uplink port cabling, 2-4 description, 1-2 pin assignments, A-3 October 2003 4821-A2-GN21-00 Index V VT100 cabling and settings, 2-6 W wall mount bracket installation, 1-10 screw positions, 1-11 WAN, cabling uplink, 2-4 weight, C-2 4821-A2-GN21-00 October 2003 IN-3 Index IN-4 October 2003 4821-A2-GN21-00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:07:30 14:23:18-04:00 Keywords : BitStorm, 4821-A1, 4800 Express, 1U, stackable, IP, ADSL, DSL Create Date : 2003:10:10 16:11:19Z Page Count : 54 Creation Date : 2003:10:10 16:11:19Z Mod Date : 2004:07:30 14:23:18-04:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Paradyne Corporation Metadata Date : 2004:07:30 14:23:18-04:00 Creator : Paradyne Corporation Title : BitStorm 4800 Express Model 4821-A1 Installation Guide Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools