SC DX200 51724622A V08.12 Titr Sensor Bro E
User Manual: SC-DX200
Open the PDF directly: View PDF
.
Page Count: 28

Titration Sensors
Titration Sensors
pH
Argentometry & Redox
Photometry
Conductivity
Surfactants
Reference
Intelligent Sensors
for All Titration Applications

2
Experience & Innovation
Extensive Experience
with Innovative Titration Sensors
Potentiometry is the method of choice for analytical identication of one or more sub-
stances in mixed phases. Reliable and durable titration sensors from METTLER TOLEDO
with their variety of designs and perfectly matched reference systems, glass membranes
and diaphragms, are suitable for a diversity of applications.
Plug & Play means reliability
With the comprehensive range of Plug
& Play pH, platinum and silver titration sen-
sors, any application challenge can be overcome.
The Sensor Chip in the sensor head stores data such
as sensor type, serial number, calibration data and usable
life, which is automatically read out to the titrator setup when
connected. That ensures, without any action on the part of the opera-
tor, that only the correct sensor with the specic, valid data is used.

3
Precision and reliability
Alongside experienced craftsmanship, maximum utility
of automated production methods ensures the consis-
tently high quality expected of the sensors.
Enormous capabilities
METTLER TOLEDO has been a source of skills and
expertise for the production of a vast range of titration
sensors capable of meeting the specic analytical re-
quirements of every industry for over 40 years.
Smart design
A clean diaphragm is a fundamental requirement for
precise measurements. It is the interface between the
reference system and the sample. If it is clogged with
precipitation deposits, precise measurement cannot
be guaranteed. The METTLER TOLEDO ARGENTHAL™
Ag/AgCl reference system with silver-ion trap keeps the
reference electrolyte completely free of silver ions, pre-
venting precipitation with sulde, protein or TRIS buffer
containing solutions.
Guaranteed quality
No sensor leaves the production facility untested.
Only on successful completion of the nal check do
the sensors receive their individual quality certicates
ready for dispatch. Strict guidelines regarding the slope
or membrane glass resistance of the pH sensors guar-
antee ultimate performance.

4
Applications
Application Examples
from Practical Experience
The following small selection of examples shows how the right combination of
METTLER TOLEDO titration sensor and titrator provides the perfect solution for
specic segment applications.
Chemical
Precise sulfuric acid content
using the pH sensor DGi111-SC
The precise determination of sulfuric acid concentra-
tion is of major signicance not only for the chemical
industry but for others too, as small differences can
sometimes have serious consequences for product
characteristics. A titration system consisting of T70
Excellence titrator, Rondo 20 sample changer and
DGi111-SC pH sensor enables automated detection
of 9% sulfuric acid concentration with a deviation of
only 0.01% and an outstanding repeatability of only
0.05% in 6 sample series. Ultimate precision in rou-
tine analysis.
Pharmaceutical
Clotrimazole titration in acetic acid
using the pH sensor DGi113-SC
Important pharmaceuticals such as clotrimazole have
to be titrated directly in non-aqueous solvents due to
their low acidic strength. In accordance with the re-
quirements of the European approved drugs list and
USP, pure acetic acid is used as the solvent and per-
chloric acid as the titrant. The outstanding chemical
stability and ease of regeneration of the DGi113-SC´s
pH glass membrane guarantee the required durability
under such demanding conditions. The high electro-
lyte ow from the moving plastic sleeve is essential for
rapid response and stability of the sensor signal. The
DGi113-SC has all the attributes required for precise re-
sults in non-aqueous titration applications.

5
Water
Chloride titration in drinking water
using the silver ring sensor DMi141-SC
Chloride in water can occur naturally (e.g. mineral solutions such as brine)
but can also be the result of contamination by fertilizer or waste water.
Among other things, a high chloride content has a destructive effect on
concrete and ferrous metals. With the DMi141-SC, chloride in water can
be titrated with excellent repeatability (relative standard deviation < 0.5%)
over a range of concentrations from 15 ppm to 1% using the appropiate
concentration of silver nitrate titrant.
Beverages
Determining the pH and acidity
of wine using the pH sensor DGi115-SC
The pH and acidity of wine are essential parameters for assessing its
quality. Laboratories have to analyze large numbers of wine samples
for these two variables on a daily basis. A T70 and Rondo 20 sample
changer with the DGi115-SC provide the means for mastering the task as
precisely and efciently as possible.
Electroplating
Automated nickel and hypophosphite titration using
the DP5 Phototrode™ and platinum ring sensor DMi140-SC
Tribological coatings for the automotive industry consist of metal or metal
oxides electroplated or anodized from aqueous solutions. For quality assur-
ance, the baths have to be checked every day. Nickel and hypophosphite/
orthophosphite are titrated in electroless nickel baths using the DP5 and
the DMi140-SC, respectively. The two titrations are handled by two Rondo
20 sample changers that are controlled by a T90 Excellence titrator. At
least 70 samples a day can be analyzed very efciently and reliably.

6
Generalists and Specialists
for the Chemical Industry
In order to cope with the enormous breadth of analyses from raw materials to special-
ized chemicals, there is not only a need for versatile glass and metal sensors but also
for specialized sensors in order to reliably titrate in a vast diversity of sample matrices.
METTLER TOLEDO can supply the right solutions for these demands.
Chemical
D G i111- S C – the Multi-Talented Acid-Base Titration Sensor
Up to date anywhere, any time
The current data stored in the Sensor Chip such as slope and zero point, monitored sensor
life span, etc. is available to the titrator as soon as it is connected. This information provides
certainty that the DGi111-SC is always in the correct condition required for the application –
regardless of which titrator it is connected.
Mobility means exibility
The movable sleeve holder enables individual positioning of the sensor in the manual titration
vessel or on the Rondo or Rondolino sample changer. That means that smaller sample vol-
umes can be titrated in METTLER TOLEDO standard titration beakers or in Rondo 30 titration
beakers.
Simple yet stable reference
The KCl-ARGENTHAL™ system reliably delivers stable sensor signals within a temperature
range of 0 to 80 °C for the entire life of the sensor. The system is maintenance free and re-
quires only regular lling with 3 M KCl.
Reliable connection to the outside world
A small ceramic pin creates the necessary condi-
tions for slow, even outow of the electrolyte. If
samples with a high sulde or protein content are
avoided, no problems with clogging should be en-
countered.
Quick stable signals and results
The large HA-glass pH membrane has been opti-
mized for rapid response times and stable signals.
It delivers reliably repeatable results in aqueous
systems.
DGi111- SC
Order number: 51109500
pH application range: 0–14
Temperature range: 0–80 °C
Membrane glass type: HA-taped
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 3 mol/L KCl
Connection: S12 (DGi111-SC)
S7 (DG111-SC)
Detection: Plug & Play
Sensor Chip
Classic design: 89596
(DG111-SC)

7
Sb850-S7/120
DX202-SC
DGi101-SC
DGi102-Mini
DGi101-SC & DGi102-Mini – Micro Sensors for Macro Demands
DGi101-SC & DGi102-Mini
Order number: 51109507 (DGi101-SC)
51109508 (DGi102-Mini)
pH application range: 0–14
Temperature range: 0–100 °C
Membrane glass type: U-glass
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™ with silver ion trap
Reference electrolyte: 3 mol/L KCl
Connection: S12
Detection: Plug & Play Sensor Chip
Sb850-S7/120
Order number: 59904405
pH application range: 0–14
Temperature range: 0–80 °C
Sensor element: Antimony pin
Diaphragm: n/a
Shaft material: Polypropylene
Reference system: External reference required
Connection: S7
Detection: n/a
DX202-SC
Order number: 51109295
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Ext. diaphragm: Glass ber
Int. diaphragm: Glass ber
Shaft material: Polypropylene
Reference system: Ag/AgCl
Int. reference electrolyte: 3 mol/L KCl
Bridge electrolyte: 3 mol/L KCl or 1 mol/L KNO3
Connection: S7
Detection: n/a
The DGi101-SC and DGi102-Mini
are two powerful micro pH sen-
sors with 3 mm or 6 mm shafts
especially made for small sample
volumes of 5 to 20 mL and for
use on the Rondo 30 or Rondo 60
plus sample changers. With the
moveable sleeve holder, the height
can be adjusted. Samples contain-
ing suldes can be titrated with no
problem. The ARGENTHAL
™ refer-
ence system with silver ion trap
means there is no possibility of
diaphragm clogging.
This is a specic combination for
acid-base titration in media con-
taining hydrouoric acid. The an-
timony pin of the Sb850 half cell
is passivated by uoride ions and
is therefore resistant. Similarly, the
plastic shaft of the DX202-SC refer-
ence is unaffected by hydrouoric
acid. Oxides that are only soluble
in highly corrosive media can be
titrated without any trouble.
Sb850-S7/120 & DX202-SC – where Others Fear to Tread

8
No mistakes
Because of its Plug & Play Sensor Chip, the DGi116-Solvent is immediately detected as soon
as it is connected to the titrator. Mix-ups are not possible.
Perfectly shielded
The gold shielding on the inner reference provides perfect protection against electrostatic
effects. The signal noise is substantially diminished and the result quality signicantly im-
proved.
Reliable reference system
The LiCl-ARGENTHAL
™ system reliably delivers stable sensor signals within a temperature
range of 0 to 60 °C for the entire life of the sensor. The system is maintenance free and re-
quires only regular lling with 1 mol/L LiCl in ethanol.
Stable signals and easy cleaning
The movable ground glass junction ensures even ow of the electrolyte. The sensor signal
stabilizes faster and titrations can be completed in a shorter time. The smooth glass surface
prevents oil samples from sticking and considerably simplies cleaning.
Fast response times and durability
The large spherical surface area of the glass mem-
brane ensures low membrane resistance and ho-
mogeneous distribution of the potential. So, the
response time and signal noise are reduced. Due
to its chemical stability and easy regeneration, the
A41 membrane glass is ideal for non-aqueous titra-
tions in a pH range of 0 to 12.
Flexibility and Durability
for Difcult Petrochemical Samples
The METTLER TOLEDO sensors for non-aqueous titrations are optimized for rapid response
times and signal stabilization as well as for ruggedness and durability. As a result, they
easily meet the requirements of oil standards such as ASTM, IP and DIN for the titration of
petrochemical products.
Petrochemical
DGi116-Solvent – for the Most Exacting Demands
DGi116-Solvent
Order number: 51109505
pH application range: 0–12
Temperature range: 0–60 °C
Membrane glass
type:
A41 spherical
Diaphragm: Ground glass
(moveable)
Shaft material: Glass
Reference system: LiCl-ARGENTHAL™
Reference electrolyte: LiCl, 1 mol/L in ethanol
Connection: S12
Detection: Plug & Play
Sensor Chip

9
DG300-SC
DX200 DMi148-SC
DMi148-SC – Maximum Versatility, Minimum Maintenance
DMi148-SC
Order number: 51109532
pH application range: 0–14
Temperature range: 0–80 °C
Sensor element: Silver ring
Diaphragm: n/a
Shaft material: Glass
Reference system: pH glass membrane
Reference electrolyte: n/a
Connection: S12
Detection: Plug & Play Sensor Chip
DG300-SC
Order number: 51109286
pH application range: 0–14
Temperature range: 0–100 °C
Sensor element: pH glass membrane
Diaphragm: n/a
Shaft material: Glass
Reference system: External reference required
Connection: S7
Detection: n/a
The DMi148-SC is ideally suited to
detecting chloride and, by simply
suldizing the silver ring, for titrat-
ing mercaptans in petrochemical
products. Thanks to the pH glass
reference, there is no diaphragm
clogging and no electrolyte relling.
Automatically, other possible appli-
cations such as acid-base titration
using the silver ring as reference
are possible.
With this combination, you have
the option of working strictly ac-
cording to ASTM D664 specica-
tions for determining acid number
or, creating a sensor adapted spe-
cically to the sample and sample
matrix. The DG300-SC half-cell re-
acts quickly and consistently to pH
changes thanks to the large, spher-
ical membrane. The DX200 with its
replaceable bridge electrolyte and
constant electrolyte ow from the
ground glass junction is an indi-
vidually adjustable reference ideally
suited to non-aqueous media.
DG300-SC & DX200 – Individually Adaptable
DX200
Order number: 51089935
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Ext. diaphragm: Ground glass (moveable)
Int. diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Int. reference electrolyte: 3 mol/L KCl
Bridge electrolyte: 3 mol/L KCl
1 mol/L KNO3
1 mol/L LiCl in ethanol
Cable/connection: 1 m, 4 mm banana
Detection: n/a

10
Controlled Safety and Precision
for Pharmaceuticals
Titrations on the purity of pharmaceutical constituents and active ingredients are funda-
mental to ensuring their effectiveness. METTLER TOLEDO titration sensors make the re-
quired application exibility possible and offer reliability due to their intelligent design.
This ensures maximum sensor life and minimal maintenance.
Pharmaceutical/Biotechnology
DMi147-SC – Twice the Possibilities, Half the Work
Reliable detection:
All relevant sensor data for identication and status monitoring is immediately available to the
titrator thanks to the Plug & Play Sensor Chip.
Secure attachment
With the standard glass sleeve holder, the sensor can be easily and securely positioned
when tted in the titration stand.
Maintenance free reference system
The DMi147-SC has no diaphragm as the pH glass membrane provides a constant reference
potential for the platinum sensor in highly acidic and therefore adequately buffered conditions
required for redox titrations. No relling of electrolyte or cleaning of clogged diaphragms are
necessary, adding up to ease-of-use, minimum maintenance and a long service life.
Twice the capabilities
The DMi147-SC combines two sensors, making it
capable not only of redox titration using the plati-
num sensor but also of acid-base titration using the
pH sensor. In the rst case, the pH membrane is the
reference, in the second the platinum ring. In both
cases, the sample is not contaminated since there
is no outowing electrolyte. The question of the right
choice of reference electrolyte is therefore super-
uous.
DMi147-SC
Order number: 51109522
Detection range: 0–±2000 mV
pH application range: 0–14
Temperature range: 0–80 °C
Sensor element: Platinum ring
Diaphragm: n/a
Shaft material: Glass
Reference system: pH glass membrane
Reference electrolyte: n/a
Connection: S12
Detection: Plug & Play
Sensor Chip

11
InLab®717
InLab®718 DGi113-SC
DGi113-SC – Reliability for Non-Aqueous Titrations
InLab®717
Order number: 51302401
Detection range: 10 µS/cm–500 mS/cm
Temperature range: 0–100 °C
Shaft material: Epoxy
Cell constant: Dependent on beaker geometry
Cell type: 4-pole platinum
Temperature sensor: NTC
Connection/cable: Mini-Din, 1 m
Detection: Presence checking
InLab®718
Order number: 51340266
Detection range: 0.1–200 µS/cm
Temperature range: -5–100 °C
Shaft material: Epoxy
Cell constant: Dependent on beaker geometry
Cell type: 2-pole platinum
Temperature sensor: NTC
Connection/cable: Mini-Din, 1.2 m
Detection: Presence checking
The DGi113-SC is the sensor for the
best results in acid-base titration of
pharmaceuticals in non-aqueous
media using a variety of titrants
adapted to the sample matrix.
These two conductivity sensors,
which can be connected directly to
the conductivity card of an Excel-
lence titrator, are suitable for con-
ductometric acid-base or precipita-
tion titrations. They can be used in
low-ion aqueous or non-aqueous
media. They enable rapid titration
and feature zero-maintenance and
outstanding durability. For direct
measurement of conductivity, the
appropriate InLab®710/ 731 or In-
Lab®720/741 can be used accord-
ing to sample type.
More information is provided in
the Lab Sensors brochure (order
no. 51724332) or at
www.mt.com/electrode-guide
InLab®717 & InLab®718 – Tracking Down Fast-Moving Ions
D G i113 - S C
Order number: 51109502
pH range: 0–12
Temperature range: 0–60 °C
Membrane glass type: A41 cylindrical
Diaphragm: Moveable Tefzel®
Shaft material: Glass
Reference system: LiCl-ARGENTHAL™
Reference electrolyte: LiCl, 1 mol/L in ethanol
Connection: S12 (DGi113-SC)
S7 (DG113-SC)
Detection: Plug & Play Sensor Chip
Classic design: 89632 (DG113-SC)

12
Precise Detection
of Multiple Parameters in Water
The importance of water in every area of life and industry is undisputed. The enormous
variety of water types require analysis of different ions and parameters over a wide range
of concentrations under constantly maintained conditions in accordance with strict regula-
tions. That places exacting demands on the sensor systems but presents no problems for
METTLER TOLEDO titration sensors.
Water
DGi117-Water – all Your Water Titration Needs in One Sensor
No watering down of sensor data
The pH sensor calibration data stored in the Sensor Chip of the DGi117-Water are transferred
to the titrator as soon as it is connected. It can be automatically monitored if required, which
means the sensor is always in optimum condition for precise, temperature-adjusted pH mea-
surement and end point titrations.
Maintenance free reference
The double-junction design with a maintenance free internal reference system (KCl gel) en-
ables replacement of the outer reference electrolyte (1 mol/L KCl) and therefore adaptation to
the particular testing conditions.
No interference
The inner tube is electrically shielded by a gold coating, preventing interference from electro-
static charges which otherwise would cause high signal noise and drifting pH readings.
High precision in low-ion media
The electrolyte ow through the xed glass junction remains stable between 5 and 20 µL/h.
This guarantees accurate pH readings and only minimal contamination of the sample with
electrolyte.
All-inclusive
Temperature-adjusted pH readings and end point
titrations can be performed due to the integrated
Pt1000 temperature sensor.
Rapid results
The LoT glass features low membrane resistance
and ensures extremely fast response time. The thin-
walled spherical design reduces electrical resistance
even further.
DGi117-Water
Order number: 51109506
pH application range: 1–11
Temperature range: 0–100 °C
Membrane glass type: LoT spherical
Ext. diaphragm: Ground glass
Int. diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Int. reference electrolyte: KCl gel
Bridge electrolyte: 1 mol/L KCl
Connection: S12
Detection: Plug & Play
Sensor Chip

13
DMi102-SC
DMi141-SC DMi144-SC
DMi144-SC – the Long Sensor for Chemical Oxygen Demand
Chemical oxygen demand (COD)
titrations are best left to automated
systems due to the harsh chemical
conditions and high sample num-
bers. The DMi144-SC platinum ring
sensor is capable of fully automat-
ed redox titrations directly in stan-
dard decomposition vessels with
the Rondo 20 and COD kit.
The DMi102-SC and DMi141-SC
are silver ring sensors for similar
applications, e.g. titrating any ions
that form precipitations with silver.
This includes all halides (Cl-, Br-,
I-), pseudo-halides (CN-, SCN-, ...)
and, after prior suldizing of the
silver ring, suldes and mercaptans
over broad concentration ranges.
The DMi141- SC is the generalist,
the DMi102-SC is a rugged semi-
microsensor for small sample vol-
umes of 10 to 20 mL or for use on
the Rondo 30 sample changer.
DMi102-SC & DMi141-SC – Precise Titration from ppm to % Chloride and More
Precise ion-selective and conductivity measurements
Full details of sodium, ammonia, calcium and other ion-selective sensors
as well as the right choice of conductivity sensor for water analysis can
be found in the Lab Sensors brochure (order no. 51724332) or at
www.mt.com/electrode-guide.
DMi102-SC
Order number: 51109533
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Silver ring
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 1 mol/L KNO3
Connection: S12
Detection: Plug & Play Sensor Chip
DMi141-SC
Order number: 51109530
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Silver ring
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 1 mol/L KNO3
Connection: S12 (DMi141-SC)
S7 (DM141-SC)
Detection: Plug & Play Sensor Chip
Classic design: 89599 (DM141-SC)
DMi144-SC
Order number: 51109521
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Platinum ring
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 3 mol/L KCl
Connection: S12
Detection: Plug & Play Sensor Chip

14
Reliable Results
for Palatable Food
The pH level, acidity and other parameters such as salt and Vitamin C content in food
and beverages are essential in obtaining the right avor and for nutritional validation.
METTLER TOLEDO titration sensors guarantee food quality because the specic ingre-
dients can be quickly and accurately titrated according to regulations.
Food & Beverage
DGi115-SC – Optimized for Acid-Base Titration in Food and Beverages
Reliable titration
The sensor and calibration data stored in the Sensor Chip is always up to date and can be
monitored. This guarantees that the DGi115-SC is always in good condition for pH testing or
end point titrations.
Controlled conditions
Due to the ARGENTHAL
™ reference system with silver ion trap, the reference electrolyte
(3 mol/L KCl) is free of silver ions. There is no danger of food constituents such as suldes
or proteins clogging the diaphragm.
Repeatable precise results
The electrolyte ow through the xed glass junction is constant and guarantees accurate and
reproducible pH readings and end point titrations. Food ingredients sticking to the glass sur-
face can be cleaned off easily.
Fast results
The HA glass pH membrane features rapid
response time, low alkali error and out stan-
ding mechanical durability. It is the right
combination for consistently high perfor-
mance.
D Gi115 - SC
Order number: 51109504
pH application range: 0–14
Temperature range: 0–100 °C
Membrane glass type: HA cylindrical
Diaphragm: Ground glass
Shaft material: Glass
Reference system: ARGENTHAL™ with silver
ion trap
Reference electrolyte: 3 mol/L KCl
Connection: S12 (DGi115-SC)
S7 (DG115-SC)
Detection: Plug & Play Sensor Chip
Classic design: 89806 (DG115-SC)

15
DMi145-SC DM143-SC
DM143-SC – Vitamin C, SO2 and More
The DM143-SC is a simple, durable
and zero-maintenance sensor pri-
marily for redox titration of impor-
tant food ingredients such as Vita-
min C or free and total SO2 in wine.
Depending on the method or regu-
lations, titrations can be performed
with either voltametric or ampero-
metric indication.
The DMi145-SC is an ideal silver
ring sensor for chloride titrations
in foods. Contamination or clog-
ging with sticky foods such as
ketchup or samples with high fat
content are no problem thanks to
the easy-to-clean moveable plastic
diaphragm. The high electrolyte
ow from the diaphragm enables
chloride detection to ppm-accuracy
in alcoholic solutions.
DMi145-SC – Easy Detection of Chloride in Food
DMi145-SC
Order number: 51109531
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Silver ring
Diaphragm: Moveable Tefzel®
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 1 mol/L KNO3
Connection: S12
Detection: Plug & Play Sensor Chip
DM143-SC
Order number: 51107699
Detection range: 0–±2000 mV
0–200 µA
Temperature range: 0–100 °C
Sensor element: Double platinum pin
Diaphragm: n/a
Shaft material: Glass
Reference system: n/a
Reference electrolyte: n/a
Connection: S7
Detection: n/a

16
High Precision for Ultimate Functionality
in Electroplating and Electronics
Continuous monitoring of the metal ion, acid or anion content of electrochemical baths
is important for obtaining durable coatings in electroplating processes or producing
perfec tly functioning circuit boards in the electronics industry. Tough and well-designed
METTLER TOLEDO titration sensors are ideal for titrating in such demanding sample
matrices.
Electroplating & Electronics
DP5 Phototrode™
Order number: 51109300
inc. region-specic power adaptor (Europe/USA/UK) and cable
DP5 Phototrode™ – a Mini Rainbow for Metal Titrations and More
5 options for a full spectrum of titrations
With a choice of 5 wavelengths comprising 520 nm, 555 nm, 590 nm, 620 nm
and 660 nm, the DP5 can be individually adapted to the specic application. With
a suitable color indicator, a wide range of complexometric titrations is possible,
as well as acid/base, redox and turbidimetric titrations. This means that the cost
benets compared with more complex procedures such as AAS or ICP-AES can be
fully exploited.
Just like a normal sensor
Thanks to its movable sleeve holder, the DP5 can be used like any other sensor in
the titration vessel, either directly on the titrator or on a Rondo or Rondolino sam-
ple changer. It will even t in Rondo 30 titration beakers.
A long-term investment
The polypropylene design of the sensor shaft is resistant against most aqueous
and non-aqueous media. If ever there are incompatible solvent mixtures involved,
you can change to a stainless steel shaft at any time. In either case, you will have
a highly durable sensor which will provide you with reliable readings over the full
length of its extensive service life.
The right solution
The DP5 is used where potentiometric titrations are not possible, where matrix ef-
fects corrupt the output signal of the sensor or where photometry is a specied re-
quirement. It enables quick and easy titration because it requires neither condition-
ing stages nor time-consuming calibration or maintenance work. You just set the
maximum transmission or absorption, and off you go.

17
DMi140-SC
DMi101-Mini DGi112-Pro
DGi112-Pro – Specically Adaptable to the Sample
The DGi112-Pro is a double-
junction pH sensor that enables
replace ment of both the refer-
ence and the bridge electrolyte for
specic adaptation to the sample
matrix. The HA glass membrane is
distinguished by high durability and
rapid response characteristics and
the movable diaphragm prevents
clogging and is easy to clean. Ti-
tration of acid mixtures in demand-
ing electrochemical baths can be
mastered with accurate results.
The DMi140-SC and DMi101-Mini
are two platinum ring sensors for
all types of redox titrations en-
countered in the electroplating or
electronics industries, such as di-
rect titration with cerium(IV)sulfate
or back titrations with potassium
iodide or ferrous(II) ammonium
sulfate. The DMi140-SC is the gen-
eralist while the DMi101-Mini is a
rugged semi-microsensor for small
sample volumes of 10 to 20 mL or
for use on the Rondo 30 sample
changer.
DMi140-SC & DMi101-Mini – the Perfect Choice for Redox Titration
DGi112- Pro
Order number: 51109501
pH range: 0–14
Temperature range: 0–60 °C
Membrane glass type: HA cylindrical
Ext. diaphragm: Moveable Tefzel®
Int. diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Int. reference electrolyte: 3 mol/L KCl
Bridge electrolyte: 1 mol/L KCl
3 mol/L KNO3
Connection: S12
Detection: Plug & Play Sensor Chip
DMi140-SC
Order number: 51109520
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Platinum ring
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 3 mol/L KCl
Connection: S12 (DMi140-SC)
S7 (DM140-SC)
Detection: Plug & Play Sensor Chip
Classic design: 89598 (DM140-SC)
DMi101-Mini
Order number: 51109523
Detection range: 0–±2000 mV
Temperature range: 0–80 °C
Sensor element: Platinum ring
Diaphragm: Ceramic pin
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 3 mol/L KCl
Connection: S12
Detection: Plug & Play Sensor Chip

18
Durability
for Paper Production
The process of pulp digestion has to be carefully controlled in order to obtain quality
results without wasting time and money. Due to the vast production volumes, en-
ormous gains can be obtained from very minor changes to the pulping process. The
METTLER TOLEDO sensor DGi114-SC provides the ideal means for titrations in the
delignication process.
Paper & Cellulose / Cosmetics
DGi114-SC – the Tough pH Sensor for Harsh Environments
Unmistakable
Due to its Sensor Chip, the sensor is unmistakably identied. The up-to-date sensor and
calibration data stored are immediately available to the titrator, so mistakes are a thing of
the past.
Stable conditions
The ARGENTHAL
™ reference system with 3 mol/L KCL electrolyte withstands high temperatures
and frequent temperature changes – providing a long-lasting and stable reference system.
Simple maintenance
The movable diaphragm with its high electrolyte ow enables fast and reproducible potential
adjustment and adds to the ease of cleaning and maintenance – all in all an optimum design
for equivalence point titrations with difcult pulp
samples.
Durability for reliable results
The outstanding durability of the HA glass mem-
brane makes it perfect for the demanding condi-
tions of acid-base titrations of black, green or white
liquors.
D G i114 - S C
Order number: 51109503
pH application range: 0–14
Temperature range: 0–60 °C
Membrane glass type: HA cylindrical
Diaphragm: Moveable Tefzel®
Shaft material: Glass
Reference system: ARGENTHAL™
Reference electrolyte: 3 mol/L KCl
Connection: S12
Detection: Plug & Play
Sensor Chip

19
Surfactants
in a Diversity of Cosmetic Products
Due to constantly rising consumer demands, the composition of personal care products
such as creams, shampoos or shower gels has become increasingly complex. Titrations
of these samples have therefore become extremely exacting, demanding suitable
methods combined with high-performing and versatile sensors: the METTLER TOLEDO
DS800-TwoPhase and DS500 surfactant sensors.
DS800-TwoPhase
The Ultimate in Two-phase
Titration Performance
The DS800-TwoPhase is the sensor
of choice for the titration of anionic
and cationic surfactants in formula-
tions, raw products, liquid deter-
gents and shampoos using the
two-phase titration method accord-
ing to the EN 14480, 14668 and
14669 standards over a pH range
from 1 to 12. The performance ca-
pabilities of the membrane remain
entirely undiminished even after
hundreds of titrations, resulting in
reliable results over the full length
of its extensive service life.
DS800-TwoPhase
Order number: 51109540
pH applic. range: 1–12
Detection range: <10–5 mol/L
to critical micelle
concentration
Temperature range: 0–50 °C
Sensor element: Polymer membrane
Membrane
resistance:
<1 MΩ
Shaft material: POM
Reference system: External reference
required
Connection: S7
Detection: n/a
Resistant to: Ketones (MIBK),
hexane, toluene,
ethanol
With the sensor DS500, ionic
surfactants can be easily titrated
in aqueous matrices. Very often,
a method based on precipitation
titration between an anionic and
a cationic surfactant is sufcient.
Characteristic titration of that type
can be performed in samples such
as liquid detergent or household
cleaners as well as in colored so-
lutions and turbid suspensions in
a pH range of 2 to 10. Non-ionic
surfactants in raw products can
also be precisely analysed with the
DS500.
DS500
Order number: 51107670
pH applic. range: 2–10
Detection range: <10–5 mol/L
to critical micelle
concentration
Temperature range: 0–50 °C
Sensor element: Polymer membrane
Membrane
resistance:
<1 MΩ
Shaft material: PVC
Reference system: External reference
required
Connection: S7
Detection: n/a
Resistant to: Ethanol
DS500
Specically for Use
in Aqueous Systems

20
Excellent Hardware and Firmware
for Optimum Sensor Support
The sensor inputs of the METTLER TOLEDO Excellence T50, T70 and T90 titrators and the
Compact G20 titrator are optimized in terms of speed, signal-to-noise ratio and resolu-
tion. This ensures that in combination with the suitable sensor, stable pH level readings,
pH-stating with tight tolerances or demanding titrations in complex substance mixtures
can be performed to the highest quality standards.
Titration Excellence

21
Automatic chemical detection
In addition to the Plug & Play sensors the pH buffers used for sensor cali-
bration are also automatically detected by the titrator. It makes no differ-
ence in which order the buffers are measured, saving time and providing
certainty.
Expandable to conductivity
With the unique conductivity sensor card, new application possibilities
such as conductometric titrations or direct measurements can be eas-
ily and reliably done with the full functionality of a modern Excellence
titrator – there is no need for an extra meter. The conductivity card fea-
tures automatic detection of the conductivity sensor and an additional
Plug & Play pH/mV sensor input.
Fully equipped as standard
Every Excellence titrator comes with a versatile pH sensor card. There
are 2 Plug & Play compatible pH/mV sensor inputs, one of which also
features current or voltage polarization, a Pt1000 temperature sensor in-
put and a reference input. This means it has the facility for direct pH or
ISE(pX) measurement, pH end point or pH/mV/pX equivalence point titra-
tions as well as amperometric and voltametric titrations. If needed, more
sensor cards can be added in the available slots.
Ensuring performance capability
In order to ensure the performance capabilities of the sensor inputs, they
can be periodically adjusted with certied resistors and the test unit. The
process is traceable, unambiguously documented, and guarantees identi-
cal measurement conditions for all the sensor inputs of a sensor card. A
calibrated pH sensor can simply be switched from one input to the other
without the need for recalibration.
Efcient method development
The intelligent application modes of the titrators make method optimiza-
tion easy. Just select the titration method and titration speed and the opti-
mum control parameters are automatically set to suit the selected sensor
– simple and efcient method development.

22
Accessories
Properly Serviced and Connected
Electrolytes for reference systems Order no.
25 mL
Order no.
250 mL
Order no.
6x250 mL
KCl 3 mol/L solution for ARGENTHAL™ reference systems and as bridge
electrolyte (DGi101-SC, DGi102-Mini, DG(i)111-SC, DMi101-Mini,
DM(i)140-SC, DGi112-Pro, DGi114-SC, DG(i)115-SC, DX200,
DX202-SC)
51343180 51340049 51340050
1 mol/L KNO3 (DMi102-SC, DM(i)141-SC, DMi145-SC, DX200,
DX202-SC) 51343182 51340047 51340234
Solutions for reference systems: bridge electrolytes
1 mol/L KCl (DGi112-Pro, DGi117-Water, DX200, DX202-SC) 51343181
Solutions for surfactant sensors
Inner electrolyte for the DS500 51107899
Inner electrolyte for the DS800-TwoPhase 51109542
Emulsier for two-phase titration with the DS800-TwoPhase 51109543
Cleaning solutions
Pepsin hydrochloric acid for cleaning protein contamination from dia-
phragms. Acting time approx. 1 hour 51340068
Thiourea solution for cleaning silver sulde contamination from dia-
phragms. Acts to discoloration 51340070
Reactivation solution for regenerating pH glass sensors. Acting time 1 min 51340073
Conductivity standards Order no.
6x250 mL
Order no.
250 mL
Order no.
30 sachets of 20 mL
84 µS/cm 51302153
1413 µS/cm 51300259 51300138 51302049
12.88 mS/cm 51300260 51300139 51302050
Accessory Description Order number
DT1000 temperature sensor Pt1000 temperature sensor for temperature-compensation of pH-level readings 51109828
Wetting caps (minimum order
5 items)
For sensors with shaft diameter of 12 mm 51340020
For sensors with ground diaphragm (DGi112-SC, DG(i)113-SC, DGi114-SC,
DG(i)115-SC, DGi116-Solvent, DGi117-Water)
51340022
For sensors with shaft diameter of 8 mm
(DGi102-Mini, DMi101-Mini, DMi102-SC)
51340021
For sensors with shaft diameter of 6 mm (DGi101-SC) 51340019
Electrolyte and Cleaning Solutions
METTLER TOLEDO offers an extensive range of electrolytes and cleaning solutions, which are indispensable for
correct maintenance and care, and consequently for trouble-free and extended sensor life.
Useful Accessories
Whether a temperature sensor for temperature-compensated pH measurement or simply wetting caps for correct
storage of titration sensors are required, METTLER TOLEDO offers useful accessories.

23
Connection Cable length (cm) Designation Connector Order number
S7 grey
70
Lemo
51109183
100 51109184
160 51109185
Connection Cable length (cm) Designation Connector Order number
S12 grey
70
Lemo
89601
100 89602
160 51108034
MultiPin™
70
Lemo/Pt1000
51109544
100 51109545
Buffer solutions pH level at 25 °C Order no.
250 mL
Order no.
6x250 mL
Order no.
1000 mL
Order no. 30 sa-
chets of 30 mL
Standard pH
buffer solutions
2.00 51340055 51319010 51319011
4.01 51340057 51340058 51340228 51302069
7.00 51340059 51340060 51340229 51302047
9.21 51300193 51300194 51340230 51302070
10.00 51340056 51340231 51340232 51302079
11.00 51340063 51319018 51319019
Rainbow I (3x10 sachets of 20 mL 4.01/7.00/9.21) 51302068
Rainbow II (3x10 sachets of 20 mL 4.01/7.00/10.00) 51302080
pH buffer solutions
according to NIST and
DIN 19266
4.006 51340039
6.885 51340041
9.180 51340042
10.012 51340044
DKD certied buffer so-
lutions
4.01 52118093 51319059
7.00 52118094 51319060
9.21 52118095 51319061
10.00 52118096 51319062
Redox buffer solutions
E (Ag/AgCl) 25 °C
220 mV UH =
427 mV 51340065 51340081
Cables for Plug & Play and Classic Sensors
The METTLER TOLEDO Plug & Play sensors require a Plug & Play cable for connection to the titrators. This cable
can also be used for classical sensors with the exception of the DM143-SC.
Multiple shielding prevents electrostatic effects on the transmission of measurement and reference signals or the
Sensor Chip data.
DM143-SC double platinum pin sensor: for this model, classic sensor cables are used, which can also be
used with all classic sensors. As with the Plug & Play cables, the signal integrity is protected from interference
effects.
Buffer Solutions with Quality Test Certicate
Any pH measurement and end point titration can only be as accurate as the buffer solutions used for calibrat-
ing the pH sensor. The internationally valid pH scale is dened according to the standard reference materials
(SRMs) of the NIST (National Institute of Standards and Technology, USA). The buffer solutions supplied by
METTLER TOLEDO are provided with a quality test certicate that guarantees the stated specications and com-
pliance with the standards. They are ideally suited for use in quality systems.
You can download their test certicates from www.mt.com/buffer and the safety data sheets from
www.mt.com/msds.

24
pH Platinum Silver Sur-
factant
Color
Conduc-
tivity,
titration
Antimony
Refer-
ence ISE
Conduc-
tivity,
direct-
measure-
ment
Sensor name
DGi101-SC
DGi102-Mini
DGi111-SC
DGi112-Pro
DGi-114-SC
DGi115-SC
DGi117-Water
DG300-SC
DGi113-SC
DGi116-Solvent
DMi101-Mini
DMi140-SC
DM144-SC
DMi147-SC
DM143-SC
DMi102-SC
DMi141-SC
DMi145-SC
DMi148-SC
DM405-SC
DS800-TwoPhase
DS500
DP5 Phototrode™
InLab®717
InLab®718
Sb850
DX200
DX202-SC
DX2
18, 219, 223, 240
DX264
InLab®710, 731
InLab®720, 741
Industry Titration application Titration type 7 7 6 17 18 14 12 9 11 8 17 17 13 10 15 13 13 15 9 - 19 19 16 11 11 7 9 7 * * * *
Chemical
Acidic and basic solutions Acid-/base, aqueous, potentio- or conductometric ••••••• ••
Concentrated alkalis Acid-/base, aqueous ••••••
Nitrating acids Acid-/base, non-aqueous •
SiO2 and Na2O in water glass Acid-/base, aqueous • •
Acidity/alkalinity of polyols Acid-/base, non-aqueous •
Chlorine and chlorate in alkalis Redox, iodometric • •
Chloride in alcohol solutions Precipitation •••••
Identication of indigo and hydrosulphite Redox, iodometric •
Petrochemical
TAN according to ASTM D664, IP177, EN12634 Acid-/base, non-aqueous • • • •
TBN according to ASTM D4739, IP276, ISO 3771, ASTM D2896 Acid-/base, non-aqueous • • • •
Mercaptans in oils according to ASTM D3227, IP272, ISO 3012 Precipitation, non-aqueous •••••
Chloride in crude oil Precipitation, non-aqueous •
Bromine number according to ASTM D1159, IP130, ISO 3839 Redox, bromatometric •
Iodine value in biodiesel according to EN14111 Redox, iodometric • •
Titration of oils according to IP400 Conductometric •
Epoxy value of polymers (ASTM D1652, DIN 53188) Acid-/base, non-aqueous • • •
Peroxide number in oils Redox, iodometric • •
Acid numb. in B100 biodiesel (EN14104)
or E85 bioethanol (ASTM D1613) Acid-/base, non-aqueous, potentio- or photometric • • •
Pharmaceutical/
Biotechnology
Pharmaceutical constituents and active ingredients
(aspartame, clotrimazole, etc.) Acid-/base, non-aqueous potentiometric, conductometric • • • •
Pharmaceutical constituents and active ingredients
(phenol, glycerine, ampicillin, vitamin E, etc.) Redox, bromatometric, iodometric, cerimetric • • •
Sulfonamides Redox, diazotitration • •
Halides according to the European Pharmacopoeia and USP Precipitation • • •
Chloride in physiological solutions Precipitation, potentiometric • •
Non-ionic surfactants in pharmaceutical products Precipitation, photometric (turbidity) •
Free acids in glycerine according to Pharmacopoeia 5.0 Acid-/base, aqueous • •
Conductivity of puried water to USP26 Conductivity measurement •
The Right Sensor
by Industry and Application
Applications
Using the table below (and on the following page) you can easily see which METTLER
TOLEDO titration sensor is best for your particular industry and application. For more de-
tailed information on the individual sensors refer to the indicated pages of the brochure.

25
pH Platinum Silver Sur-
factant
Color
Conduc-
tivity,
titration
Antimony
Refer-
ence ISE
Conduc-
tivity,
direct-
measure-
ment
Sensor name
DGi101-SC
DGi102-Mini
DGi111-SC
DGi112-Pro
DGi-114-SC
DGi115-SC
DGi117-Water
DG300-SC
DGi113-SC
DGi116-Solvent
DMi101-Mini
DMi140-SC
DM144-SC
DMi147-SC
DM143-SC
DMi102-SC
DMi141-SC
DMi145-SC
DMi148-SC
DM405-SC
DS800-TwoPhase
DS500
DP5 Phototrode™
InLab®717
InLab®718
Sb850
DX200
DX202-SC
DX2
18, 219, 223, 240
DX264
InLab®710, 731
InLab®720, 741
Industry Titration application Titration type 7 7 6 17 18 14 12 9 11 8 17 17 13 10 15 13 13 15 9 - 19 19 16 11 11 7 9 7 * * * *
Chemical
Acidic and basic solutions Acid-/base, aqueous, potentio- or conductometric ••••••• ••
Concentrated alkalis Acid-/base, aqueous ••••••
Nitrating acids Acid-/base, non-aqueous •
SiO2 and Na2O in water glass Acid-/base, aqueous • •
Acidity/alkalinity of polyols Acid-/base, non-aqueous •
Chlorine and chlorate in alkalis Redox, iodometric • •
Chloride in alcohol solutions Precipitation •••••
Identication of indigo and hydrosulphite Redox, iodometric •
Petrochemical
TAN according to ASTM D664, IP177, EN12634 Acid-/base, non-aqueous • • • •
TBN according to ASTM D4739, IP276, ISO 3771, ASTM D2896 Acid-/base, non-aqueous • • • •
Mercaptans in oils according to ASTM D3227, IP272, ISO 3012 Precipitation, non-aqueous •••••
Chloride in crude oil Precipitation, non-aqueous •
Bromine number according to ASTM D1159, IP130, ISO 3839 Redox, bromatometric •
Iodine value in biodiesel according to EN14111 Redox, iodometric • •
Titration of oils according to IP400 Conductometric •
Epoxy value of polymers (ASTM D1652, DIN 53188) Acid-/base, non-aqueous • • •
Peroxide number in oils Redox, iodometric • •
Acid numb. in B100 biodiesel (EN14104)
or E85 bioethanol (ASTM D1613) Acid-/base, non-aqueous, potentio- or photometric • • •
Pharmaceutical/
Biotechnology
Pharmaceutical constituents and active ingredients
(aspartame, clotrimazole, etc.) Acid-/base, non-aqueous potentiometric, conductometric • • • •
Pharmaceutical constituents and active ingredients
(phenol, glycerine, ampicillin, vitamin E, etc.) Redox, bromatometric, iodometric, cerimetric • • •
Sulfonamides Redox, diazotitration • •
Halides according to the European Pharmacopoeia and USP Precipitation • • •
Chloride in physiological solutions Precipitation, potentiometric • •
Non-ionic surfactants in pharmaceutical products Precipitation, photometric (turbidity) •
Free acids in glycerine according to Pharmacopoeia 5.0 Acid-/base, aqueous • •
Conductivity of puried water to USP26 Conductivity measurement •
* See Lab Sensors brochure (order no. 51724332) or www.mt.com/electrode-guide
see brochure page

26
pH Platinum Silver Sur-
factant
Color
Conduc-
tivity,
titration
Antimony
Refer-
ence ISE
Conduc-
tivity,
direct-
measure-
ment
Sensor name
DGi101-SC
DGi102-Mini
DGi111-SC
DGi112-Pro
DGi-114-SC
DGi115-SC
DGi117-Water
DG300-SC
DGi113-SC
DGi116-Solvent
DMi101-Mini
DMi140-SC
DM144-SC
DMi147-SC
DM143-SC
DMi102-SC
DMi141-SC
DMi145-SC
DMi148-SC
DM405-SC
DS800-TwoPhase
DS500
DP5 Phototrode™
InLab®717
InLab®718
Sb850
DX200
DX202-SC
DX2
18, 219, 223, 240
DX264
InLab®710, 731
InLab®720, 741
Industry Titration application Titration type 7 7 6 17 18 14 12 9 11 8 17 17 13 10 15 13 13 15 9 - 19 19 16 11 11 7 9 7 * * * *
Water
Acidity/alkalinity of domestic, natural source and rainwater Acid-/base, aqueous •••••••
Total hardness of water Complexometry, photometric and potentiometric • • •
Chemical oxygen demand (COD) Redox, chromatometric •••
Perborate, percarbonate, persulfate in water Redox, iodometric • • •
Chlorine residues according to ASTM D1253 Redox, arsenometric, amperometric indication •
Chloride in water Precipitation • •
Ammonia, uoride, sodium and calcium in water Direct measurement •
Conductivity of domestic, natural source and rainwater Conductivity measurement • •
Food & beverages
Vitamin C in food and beverages Redox with amperometric or voltametric indication •
Acid content of fruit/vegetable juices, wine, milk, vinegar Acid-/base, aqueous ••••••
Chloride in foods (ketchup, vegetable juices, spices) Precipitation •••
Free and total sulfur dioxide in wine Redox, iodometric, voltametric indication •
Reducing sugar according to Rebelein Redox, iodometric • •
Saponication no. of fats in oil, margarine, butter (DIN 53401)
Acid-/base, aqueous •
Acid number of oils, margarine, fats Acid-/base, non-aqueous • •
Peroxide number of edible oils and fats Redox, iodometric • • •
Electronics/electro-
plating/engineering/
automotive
Anionic/cationic surfactants in coolant/lubricants
Two-phase precipitation (EN14468, 14469, 14480)
•
Nickel in electroless nickel baths Complexometry, photometric •
Hypophosphite/orthophosphite in electroless nickel baths Redox, iodometric • •
Free cyanide in zinc baths Precipitation • • •
Acid mixtures in electrolysis baths Acid-/base, aqueous • •
Cr(VI), Sn(II) in electrolysis baths Redox, iodometric • •
Cu(II) and Zn(II) in electrolysis baths Complexometry, potentiometric •
Hydrogen peroxide Redox, cerimetric • •
Cosmetics
Anionic surfactants in liquid detergents Precipitation, single-phase, aqueous •
Anionic/cationic surfactants in cosmetic products
Two-phase precipitation (EN14468, 14469, 14480)
•
Non-ionic surfactants in raw materials Precipitation, photometric (turbidity) •
Betaine content in shampoo Acid-/base, non-aqueous • •
Paper/cellulose, tex-
tiles
ABC titration of white and green liquor Acid-/base, aqueous • •
Suldes in green and black liquor Precipitation •••
Kappa number determination Redox, iodometric • •
Raw materials and
precious metals
Gold Redox, cerimetric • •
Silver in alloys Precipitation • •
Al(III), Fe(III), Ca(II), Mg(II) in cement components (EN196-2) Complexometry, photometric •
Flavours, fragrances,
food ingredients
Aldehydes in oil of lemons according to AOAC 955:32 Acid-/base, aqueous ••••
Peroxide number of etheric oils, essences Redox, iodometric •
Applications
The Right Sensor
by Industry and Application

27
pH Platinum Silver Sur-
factant
Color
Conduc-
tivity,
titration
Antimony
Refer-
ence ISE
Conduc-
tivity,
direct-
measure-
ment
Sensor name
DGi101-SC
DGi102-Mini
DGi111-SC
DGi112-Pro
DGi-114-SC
DGi115-SC
DGi117-Water
DG300-SC
DGi113-SC
DGi116-Solvent
DMi101-Mini
DMi140-SC
DM144-SC
DMi147-SC
DM143-SC
DMi102-SC
DMi141-SC
DMi145-SC
DMi148-SC
DM405-SC
DS800-TwoPhase
DS500
DP5 Phototrode™
InLab®717
InLab®718
Sb850
DX200
DX202-SC
DX2
18, 219, 223, 240
DX264
InLab®710, 731
InLab®720, 741
Industry Titration application Titration type 7 7 6 17 18 14 12 9 11 8 17 17 13 10 15 13 13 15 9 - 19 19 16 11 11 7 9 7 * * * *
Water
Acidity/alkalinity of domestic, natural source and rainwater Acid-/base, aqueous •••••••
Total hardness of water Complexometry, photometric and potentiometric • • •
Chemical oxygen demand (COD) Redox, chromatometric •••
Perborate, percarbonate, persulfate in water Redox, iodometric • • •
Chlorine residues according to ASTM D1253 Redox, arsenometric, amperometric indication •
Chloride in water Precipitation • •
Ammonia, uoride, sodium and calcium in water Direct measurement •
Conductivity of domestic, natural source and rainwater Conductivity measurement • •
Food & beverages
Vitamin C in food and beverages Redox with amperometric or voltametric indication •
Acid content of fruit/vegetable juices, wine, milk, vinegar Acid-/base, aqueous ••••••
Chloride in foods (ketchup, vegetable juices, spices) Precipitation •••
Free and total sulfur dioxide in wine Redox, iodometric, voltametric indication •
Reducing sugar according to Rebelein Redox, iodometric • •
Saponication no. of fats in oil, margarine, butter (DIN 53401)
Acid-/base, aqueous •
Acid number of oils, margarine, fats Acid-/base, non-aqueous • •
Peroxide number of edible oils and fats Redox, iodometric • • •
Electronics/electro-
plating/engineering/
automotive
Anionic/cationic surfactants in coolant/lubricants
Two-phase precipitation (EN14468, 14469, 14480)
•
Nickel in electroless nickel baths Complexometry, photometric •
Hypophosphite/orthophosphite in electroless nickel baths Redox, iodometric • •
Free cyanide in zinc baths Precipitation • • •
Acid mixtures in electrolysis baths Acid-/base, aqueous • •
Cr(VI), Sn(II) in electrolysis baths Redox, iodometric • •
Cu(II) and Zn(II) in electrolysis baths Complexometry, potentiometric •
Hydrogen peroxide Redox, cerimetric • •
Cosmetics
Anionic surfactants in liquid detergents Precipitation, single-phase, aqueous •
Anionic/cationic surfactants in cosmetic products
Two-phase precipitation (EN14468, 14469, 14480)
•
Non-ionic surfactants in raw materials Precipitation, photometric (turbidity) •
Betaine content in shampoo Acid-/base, non-aqueous • •
Paper/cellulose, tex-
tiles
ABC titration of white and green liquor Acid-/base, aqueous • •
Suldes in green and black liquor Precipitation •••
Kappa number determination Redox, iodometric • •
Raw materials and
precious metals
Gold Redox, cerimetric • •
Silver in alloys Precipitation • •
Al(III), Fe(III), Ca(II), Mg(II) in cement components (EN196-2) Complexometry, photometric •
Flavours, fragrances,
food ingredients
Aldehydes in oil of lemons according to AOAC 955:32 Acid-/base, aqueous ••••
Peroxide number of etheric oils, essences Redox, iodometric •
* See Lab Sensors brochure (order no. 51724332) or www.mt.com/electrode-guide
see brochure page

www.mt.com
Everything under control
METTLER TOLEDO LabX offers se-
cure data archiving, efcient data
management with control charts
and individual search lters, and
fast and clearly organized method
development for all application-
related challenges. All installation,
preparation and analysis tasks
can be performed on a PC and are
therefore fully recorded in the audit
trail. All resources such as titrant
calibration or titrant standards can
be edited on the PC and printed
out. Plug & Play sensors and bu-
rettes are automatically detected and all relevant data is monitored by
LabX for time in service and expiration of calibration.
For more information
Fully automated titration
The METTLER TOLEDO Rondo sample changer plat-
form used in conjunction with the Excellence titra-
tors forms exceptionally versatile and high-perfor-
mance titration systems. It is made
possible by the modular design,
the intuitive controls and the Plug &
Play hardware. This means you can
congure your day-to-day titrations
with ease, start them at the press of
a button and let them run automati-
cally without intervention.
LabX® titration software
Rondo sample changers
Quality certificate. Development, production
and testing according to ISO 9001.
Environmental management system
according to ISO 14001.
“European conformity”. The CE conformity
mark provides you with the assurance that
our products comply with the EU directives.
Mettler-Toledo AG, Analytical
CH-8603 Schwerzenbach, Switzerland
Tel. +41 44 806 77 11
Fax +41 44 806 72 40
Subject to technical changes
© 08/2012 Mettler-Toledo AG, 51724622A
Marketing Titration / MarCom Analytical