Manuale_Tecnico_posto_interno_MINI_Art.6701_Art.6700_3ED_EN_cod.2G40001629 6701W Technical Manual

6701W-tech-manual 6701W-tech-manual

6701W-tech-manual 6701W-tech-manual

User Manual: 6701W technical manual

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadManuale_Tecnico_posto_interno_MINI_Art.6701_Art.6700_3ED_EN_cod.2G40001629 6701W Technical Manual
Open PDF In BrowserView PDF
EN
TECHNICAL
MANUAL

Mini
art. 6701- art. 6700

Passion.Technology. Design.

Warning
Intended use
This Comelit product was designed for use in the creation of audio and video communication systems in residential,
commercial or industrial settings and in public buildings or buildings used by the public.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with
careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Cut off the power supply before carrying out any maintenance procedures.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system
manual.
We advise against running the system wires through the same duct as the power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets
• make sure the system created using Comelit products has not been tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance
with the indications provided in the Manuals / Instruction sheets.
Any repair work must be carried out
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A. does not assume any responsibility for
• any usage other than the intended use
• non-observance of the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this Manual / Instruction
sheet at any time and without prior notice.

Table of contents
Warning............................................................................................. 2
Monitor description.......................................................................... 3
Soft-touch keys description.....................................................................4

Riser addresses.............................................................................. 15
Operating distances with Art. 4888C............................................ 16
Wiring diagrams with Art. 4888C.................................................. 17

Indicator LED description........................................................................4

System with Art. 4888C: 1 Ikall series external unit.............................17

Installation......................................................................................... 5

System with Art. 4888C: 2 main monitors in cascade connection.....18

Removing / Fitting the terminal...............................................................6

System with Art. 4888C: 2 main monitors

Fitting upgrade KIT Art. 6733W................................................................6

and 1 secondary monitor in branch connection..................................18

Monitor configuration...................................................................... 7

and 1 secondary monitor in cascade connection................................18

Advanced monitor configuration.............................................................8

Operating distances with KIT 8461M-MB.................................... 19
Operating distances with Art. 1210............................................... 20
Wiring diagrams with KIT 8461M-MB and Art.1210.................... 21

Warning................................................................................................8
Programming for intercom call.............................................................8
Programming/deleting intercom address
(selective intercom only)...............................................................8
Programming buttons for intercom call........................................9
Direct programming of intercom call..........................................10
Programming keys for generic or coded actuator.............................11
Programming buttons for other functions..........................................12
Programming range...........................................................................13
Monitor ringtone selection.................................................................13
Programming reset............................................................................14

2

System with Art. 4888C: 2 main monitors

Standard configuration for soft-touch keys...........................................7

KIT 8461M-MB: standard single-family system...................................21
System with Art. 1210.............................................................................21
KIT 8461M-MB or system with Art. 1210:
secondary monitor in branch connection.............................................22
KIT 8461M-MB or system with Art. 1210:
2 additional secondary monitors in cascade connection...................22

Floor door call connection variant................................................ 22

Monitor description

1

7
8

2
3

4

9
10
11

5
6

1

2

L

L

C

F

P

1

C

F

P

2

12

1. Brightness control
ff To increase the value, turn clockwise
2. Colour intensity adjustment for Art. 6701
Contrast adjustment for B/W monitor Art. 6700
ff To increase the value, turn clockwise
3. 4.3’’ LCD screen (in colour for Art. 6701, B/W for Art. 6700)
4. Call volume adjustment (high - medium - low)
5. Soft-touch keys
6. Monitor handset (lift handset to start communication)
7. S1 User code programming microswitches (see table on page. 15)
8. S2 Button and function programming microswitches (marked with a red corner)
DIP 1-2-3-4 for button function programming
DIP 5-6 access to programming
DIP 7 for power supply voltage management (see diagrams and variants on page 17), default = OFF
For systems with 2-wire KIT or Art. 1210, set DIP 7 to ON.
DIP 8:
ON secondary monitor
OFF main monitor (default)
A maximum of 1 main monitor can be set in systems with 2-WIRE KIT or Art. 1210, and 2 main monitors in systems
with Art. 4888C.
9. Loudspeaker volume adjustment (for setting intercom audio only)
10. CV5 Video closing jumper
11. Pin for securing terminal block
12. Space for housing the operation accessory for keys
separately for white monitors Art. 6733W)

(standard on all black monitors, available to purchase

Terminal block for system connection
LL Bus line connection terminals
CFP1 CFP2 Floor door call input

3

Soft-touch keys description
ff Press the desired key once to activate the function associated with it
Wait for approximately 1 sec. before pressing the same key again. Pressing the same key several times in quick
succession will cancel the command.
Lock-release key
Key 1 Actuator function (programmable)
Key 2 Self-ignition function (programmable)
Privacy key
Keys (programmable) present as standard on all black monitors (for white monitors the KIT with additional buttons Art.
6733W is available to purchase separately)

Indicator LED description
Lock-release LED
slow flashing: door open;
1 flash after pressing: door opening confirmation;
continuous flashing: call in progress.
Privacy LED (red)
steady: privacy function enabled
3 flashes (every 5 sec.): doctor function enabled
continuous flashing: device in programming mode
4 flashes: system engaged
The monitor Art. 3701/6700 is designed for use in colour systems, in the SB2 section downstream of Art. 4888C, or
in systems without mixer, such as the system with 2-wire KIT or Art. 1210.

4

Installation
17,5 cm

16,0 cm

optional
fixing

1A

1B

1C

2

3

4

CLACK!

1

CLACK!

3

2

1
CLACK!

5

2

6

7
5

Removing / Fitting the terminal
2

1

1

2

3
L

L

2
FP
C

1
FP
C

3

Fitting upgrade KIT Art. 6733W

2

L

L

C

F

P

1

C

F

P

2

2

1

1

1

3

2

3

1
1
2
(to remove)

2

1

4

5

6
CLACK!
1

CLACK!
3

2

2

2

1

7
6

1

CLACK!

8

2

9

Monitor configuration
Standard configuration for soft-touch keys
Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art. 6733W /
Art. 6701B / 6701B/BM

DIP S2
DIP 1 DIP 2 DIP 3 DIP 4

P1

P2

P3

P4

P5

P6

0

0

0

0

ACT

AI

CCS

D

PAN

K

1

0

0

0

CCS

AI

INT

INTb

D

ACT

0

1

0

0

INT

AI

INTb

ACT

CCS

CCP

1

1

0

0

ACT

CCS

CCP

PAN

K

D

0

0

1

0

ACT

ACT

ACT

ACT

ACT

ACT

1

0

1

0

INT

ACT

CCS

CCP

INTb

PAN

0

1

1

0

AI

D

K

CCS

CCP

INTb

1

1

1

0

INTb

INT

AI

INT

PAN

D

0

0

0

1

CCS

PAN

D

AI

INT

INTb

1

0

0

1

K

CCS

PAN

CCP

AI

INT

0

1

0

1

CCP

K

PAN

ACT

INT

AI

1

1

0

1

PAN

CCP

CCS

K

ACT

D

0

0

1

1

INTb

AI

INT

ACT

D

CCS

1

0

1

1

INT

INT

INT

INT

INT

INT

0

1

1

1

NULL

NULL

NULL

NULL

NULL

NULL

1

1

1

1

ACT

NULL

PROG

Standard configuration for DIP switches 1-2-3-4
Legend
Lock- release
ACT
AI

Actuator
Self-ignition

CCP

Main switchboard call – not for use in systems with KIT

CCS

Secondary switchboard call – not for use in systems with KIT

K

Guardian doorentry phone call

D

Doctor

PAN

Panic – not for use in systems with KIT

INT

Programmable intercom, general or selective - standard singlefamily calling for KIT and Simplebus Top

INTb

Two-family intercom - for KIT only

NULL

No function

PROG

Programmed functions, see pages 8-12.
In this Dip switch setting, the buttons control the programmed functions; the NON-programmed buttons
control functions referred to on line 0000 (default).
7

Advanced monitor configuration
Warning
If the default settings (see table on page 7) do not reflect requirements, the keys can be programmed differently by carrying
out the steps below.
At the end, set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting in the configuration tables on pages
8-12). In this dip switch setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000 (see table on page 7). Restore the user code setting on S1, see table A on page 15.
Programming for intercom call
General intercom: function allowing calls to one or more internal units identified by the same call address as used
by the external unit.
Selective intercom: function allowing calls to one or more internal units identified by a dedicated call address (see
table B, page 8) which is different from the one used by the external unit.
General and selective intercoms CANNOT be used together on the same riser.
Programming/deleting intercom address (selective intercom only)
Take note of the S2, S1 setting and restore it when programming is complete

1)

2)

DIP OFF

Programming; set code,
TAB. B on page 8

S2 DIP

3)

S2

1 2 3 4 5 6
0 0 0 1 1 1

S1

Cancellation
S2 DIP

DIP ON

S2

1 2 3 4 5 6
1 1 1 1 1 1

S1

Selective intercom addresses
You must set the intercom address on all the riser’s internal units.
You can assign the same intercom address to a maximum of 3 internal units.
For group calls, select the desired intercom codes simultaneously (max. 3).
TAB. B

8

Code

Dip switch ON

1

S1

Code

Dip switch ON

1

5

5

2

2

6

6

3

3

7

7

4

4

8

8

S1

Programming buttons for intercom call
Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) +
Art. 6733W Art. 6701B / 6701B/BM

DIP S2
DIP 1 DIP 2 DIP 3 DIP 4

P1

0

0

0

0

1

0

0

0

0

1

0

0

1

1

0

0

0

0

1

0

1

0

1

0

0

1

1

0

1

1

1

0

0

0

0

1

1

0

0

1

0

1

0

1

1

1

0

1

0

0

1

1

INTb

1

0

1

1

INT

0

1

1

1

1

1

1

1

P2

INT

P3

P4

INT

INTb

P5

P6

INTb

INT

INTb
INTb

INTb

DIP S1

INT

ADDRESS

INT
INT

INTb
INT

INT

INT
INT

INT

INT

INT

INT

PROG

Example 1 - all systems (INCLUDING KITS!) - General intercom
on a monitor with user code 5, P3 programming = general internal call, P4 = general intercom with address 9
Example 2 - Selective intercom
on a monitor with user code 1 and intercom address 1, P3 programming = selective intercom with address 2, P4 = selective
intercom with address 3
1. Set S2 DIP switch 6 to the combination 01.
»» the privacy LED flashes.
S2 DIP
1 2 3 4 5 6 S2
0 0 0 0 0 1

2. Refer to the table on page 9 and select a combination in which the intercom function (either INT or INTb) is listed for the
keys you wish to program.
E.g. 1: for P3= general internal call, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set S1
with address 5 in accordance with table A on page 15, go to point 3.
E.g. 1: for P4= general intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with
address 9 in accordance with table A on page 15, go to point 3.
E.g. 2: for P3= single-family intercom, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set
S1 with address 2 in accordance with table B on page 8, go to point 3.
E.g. 2: for P4= selective intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with
address 3 in accordance with table B on page 8, go to point 3.
3. Press and release the key to be associated with the function
»» the lock-release LED lights up.
»» a confirmation tone will sound.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00
ff the privacy LED switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code
setting on S1, see table A on page 15.
9

Direct programming of intercom call
Allows direct programming of intercom call via the internal units.
√√ Requires 2 operators
Step 1: enter programming mode
Operator 1 and Operator 2 carry out the following procedures on 2 internal units:
1. Set S2 DIP switches 1-2 -3-4 to the combination 1111
2. Lift the handset
3. Press and hold the privacy and lock-release keys for 3 sec.
»» The internal unit emits 1 tone.
»» The privacy LED flashes.
»» The internal unit enters audio mode.
»» At this point the 2 operators will be communicating with each other.
Step 2: intercom call programming
Operator 1:
ff Press the key you want to program to call operator 2 (e.g. 2).
»» The internal unit manned by operator 1 emits a confirmation tone.
Operator 2:
ff Press the key you want to program to call operator 1 (e.g. 1).
»» The internal unit manned by operator 2 emits a confirmation tone.
Operator 1/ Operator 2:
ff Hang up the handset.
»» The internal unit emits 1 tone.
»» Programming of the 2 internal units is now complete.
To program another internal unit, move on to STEP 3.
Step 3: programming other internal units
Operator 1/ Operator 2:
1. Once the new station has been reached, carry out step 1 to begin communication
2. Repeat step 2
NOTE If a call is received during programming, it must be answered and the programming procedure resumed
afterwards.

10

Programming keys for generic or coded actuator
Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) +
Art. 6733W Art. 6701B / 6701B/BM

DIP S2
DIP 1 DIP 2 DIP 3 DIP 4

P1

0

0

0

0

1

0

0

0

0

1

0

0

1

1

0

0

ACT

0

0

1

0

ACT

1

0

1

0

0

1

1

0

1

1

1

0

0

0

0

1

1

0

0

1

0

1

0

1

1

1

0

1

0

0

1

1

1

0

1

1

0

1

1

1

1

1

1

1

P2

P3

P4

P5

DIP S1

P6

ACT
ACT
ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT
ADDRESS

ACT
ACT
ACT

PROG

Example:
on a monitor with user code 5, P1 programming = generic actuator, P2 = coded actuator (code 125)
Take note of the DIP-switch settings
1. Set S2 DIP switch 6 to the combination 01.
»» the privacy LED flashes.
S2 DIP
1 2 3 4 5 6 S2
0 0 0 0 0 1

2. Refer to the table on page 11 and select a combination in which the actuator function (ACT) is listed for the keys you
wish to program.
E.g.: for P1= generic actuator, set S2 DIP switches 1-2-3-4 to the combination 0000 or 1100 or 0010 (P1=ACT), set S1 DIP
switches to the combination 11111111, go to point 3.
E.g.: for P2= coded actuator (code 125), set S2 DIP switches 1-2-3-4 to the combination 0010 or 1010 (P2=ACT), set S1
with address 125 in accordance with table A on page 15, go to point 3.
3. Press and release the key to be associated with the function.
»» the lock-release LED lights up.
»» a confirmation tone will sound.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00.
»» the privacy LED switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code
setting on S1, see table A on page 15.

11

Programming buttons for other functions
Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) + Art. 6733W
Art. 6701B / 6701B/BM

DIP S2
DIP 1 DIP 2 DIP 3 DIP 4
0

0

0

0

1

0

0

0

0

1

0

1

1

0

P1
CCS

P2

P3

P4

P5

P6

AI

CCS

D

PAN

K

AI

D

0

AI

CCS

CCP

0

0

CCS

K

D

0

1

0

1

0

1

0

0

1

1

0

1

1

1

0

0

0

0

1

CCS

PAN

D

AI

1

0

0

1

K

CCS

PAN

CCP

0

1

0

1

CCP

K

PAN

1

1

0

1

PAN

CCP

CCS

0

0

1

1

1

0

1

1

0

1

1

1

1

1

1

1

AI

D

CCP

PAN

CCS

CCP

K

CCS

AI

NULL

NULL

CCP
PAN

D

AI
AI

K

AI
NULL

PAN

NULL

NULL

D
D

CCS

NULL

NULL

PROG

Legend
Lock- release
AI

Self-ignition

CCP

Main switchboard call – not for use in systems with KIT

CCS

Secondary switchboard call – not for use in systems with KIT

K

Guardian doorentry phone call

D

Doctor

PAN

Panic – not for use in systems with KIT

NULL

No function

PROG

Programmed functions

Example:
on a monitor with user code 5, P1 programming = self-ignition, P4 = Secondary switchboard call.
1. Set S2 DIP switch 6 to the combination 01.
»» the privacy LED flashes.
S2 DIP
1 2 3 4 5 6 S2
0 0 0 0 0 1

2. Refer to the table on page 12 and select a combination in which the desired/necessary functions are listed for the keys
you wish to program.
E.g. 1: for P1= self-ignition, P4= switchboard call, set S2 DIP switches 1-2-3-4 to the combination 0110 (P1=AI, P4=CCS).
3. Press and release the keys to which you wish to assign the functions
»» the lock-release LED lights up.
»» une tonalité de confirmation retentit.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00
»» the privacy LED switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111.
12

Programming range
Take note of the S2, S1 setting and restore it when programming is complete
Carry out steps 1 to 4
1)

2)

3)

4)

S2 DIP

Range minimum
address

1 2 3 4 5 6
0 0 0 0 1 0

S1
set code, TAB. A
on page 15

Range maximum
address

S2

Enable range

S2

DIP OFF
Disable range

S2 DIP
1 2 3 4 5 6
1 1 1 1 1 0

DIP ON

Deleting the range

S1

S2

2 sec

Monitor ringtone selection
1. Press and hold

for 6 sec.

»» a confirmation tone will sound
»» the privacy LED will flash to indicate “programming” mode.
√√ The procedure can only take place while the system is in standby; otherwise the privacy LED will flash 4 times to inform the
user that the system is engaged
2. Press and release
Once (1 confirmation tone is emitted) to change the ringtone for calls from the external unit.
Twice (2 confirmation tones are emitted) to change the ringtone for calls from the switchboard.
3 times (3 confirmation tones are emitted) to change the ringtone for intercom calls made from the internal unit.
4 times (4 confirmation tones are emitted) to change the floor door call ringtone.
Any further pressing of the
key repeats the sequence described above.
3. Press and release
4. Press

to scroll through the various available ringtones in sequence.

to confirm selection of the last ringtone heard and to exit (at any time) change monitor ringtone mode.

»» one confirmation tone is emitted
»» the privacy LED switches off
5. Repeat steps 1 to 4 to change the other ringtones.

13

Programming reset
Factory settings:
•

Button functions for the S2 DIP switch 1-2-3-4 combination;

•

Intercom address absent;

•

Range function and min./max. addresses absent;

•

Ringtone reset.

DIP OFF

Take note of the S2, S1 setting and restore it when programming is complete

1)

DIP ON
S1

2)

S2 DIP

3)

S2

1 2 3 4 5 6
1 1 1 1 1 1

5 sec

14

Riser addresses
TAB. A
Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

Code

Dip switch
ON

1

1

31

1,2,3,4,5

61

1,3,4,5,6

91

1,2,4,5,7

121

1,4,5,6,7

151

1,2,3,5,8

181

1,3,5,6,8

211

1,2,5,7,8

2

2

32

6

62

2,3,4,5,6

92

3,4,5,7

122

2,4,5,6,7

152

4,5,8

182

2,3,5,6,8

212

3,5,7,8

3

1,2

33

1,6

63

1,2,3,4,5,6

93

1,3,4,5,7

123

1,2,4,5,6,7

153

1,4,5,8

183

1,2,3,5,6,8

213

1,3,5,7,8

4

3

34

2,6

64

7

94

2,3,4,5,7

124

3,4,5,6,7

154

2,4,5,8

184

4,5,6,8

214

2,3,5,7,8

5

1,3

35

1,2,6

65

1,7

95

1,2,3,4,5,7

125

1,3,4,5,6,7

155

1,2,4,5,8

185

1,4,5,6,8

215

1,2,3,5,7,8

6

2,3

36

3,6

66

2,7

96

6,7

126

2,3,4,5,6,7

156

3,4,5,8

186

2,4,5,6,8

216

4,5,7,8

7

1,2,3

37

1,3,6

67

1,2,7

97

1,6,7

127

1,2,3,4,5,6,7

157

1,3,4,5,8

187

1,2,4,5,6,8

217

1,4,5,7,8

8

4

38

2,3,6

68

3,7

98

2,6,7

128

8

158

2,3,4,5,8

188

3,4,5,6,8

218

2,4,5,7,8

9

1,4

39

1,2,3,6

69

1,3,7

99

1,2,6,7

129

1,8

159

1,2,3,4,5,8

189

1,3,4,5,6,8

219

1,2,4,5,7,8

10

2,4

40

4,6

70

2,3,7

100

3,6,7

130

2,8

160

6,8

190

2,3,4,5,6,8

220

3,4,5,7,8

11

1,2,4

41

1,4,6

71

1,2,3,7

101

1,3,6,7

131

1,2,8

161

1,6,8

191

1,2,3,4,5,6,8

221

1,3,4,5,7,8

12

3,4

42

2,4,6

72

4,7

102

2,3,6,7

132

3,8

162

2,6,8

192

7,8

222

2,3,4,5,7,8

13

1,3,4

43

1,2,4,6

73

1,4,7

103

1,2,3,6,7

133

1,3,8

163

1,2,6,8

193

1,7,8

223

1,2,3,4,5,7,8

14

2,3,4

44

3,4,6

74

2,4,7

104

4,6,7

134

2,3,8

164

3,6,8

194

2,7,8

224

6,7,8

15

1,2,3,4

45

1,3,4,6

75

1,2,4,7

105

1,4,6,7

135

1,2,3,8

165

1,3,6,8

195

1,2,7,8

225

1,6,7,8

16

5

46

2,3,4,6

76

3,4,7

106

2,4,6,7

136

4,8

166

2,3,6,8

196

3,7,8

226

2,6,7,8

17

1,5

47

1,2,3,4,6

77

1,3,4,7

107

1,2,4,6,7

137

1,4,8

167

1,2,3,6,8

197

1,3,7,8

227

1,2,6,7,8

18

2,5

48

5,6

78

2,3,4,7

108

3,4,6,7

138

2,4,8

168

4,6,8

198

2,3,7,8

228

3,6,7,8

19

1,2,5

49

1,5,6

79

1,2,3,4,7

109

1,3,4,6,7

139

1,2,4,8

169

1,4,6,8

199

1,2,3,7,8

229

1,3,6,7,8

20

3,5

50

2,5,6

80

5,7

110

2,3,4,6,7

140

3,4,8

170

2,4,6,8

200

4,7,8

230

2,3,6,7,8

21

1,3,5

51

1,2,5,6

81

1,5,7

111

1,2,3,4,6,7

141

1,3,4,8

171

1,2,4,6,8

201

1,4,7,8

231

1,2,3,6,7,8

22

2,3,5

52

3,5,6

82

2,5,7

112

5,67

142

2,3,4,8

172

3,4,6,8

202

2,4,7,8

232

4,6,7,8

23

1,2,3,5

53

1,3,5,6

83

1,2,5,7

113

1,5,6,7

143

1,2,3,4,8

173

1,3,4,6,8

203

1,2,4,7,8

233

1,4,6,7,8

24

4,5

54

2,3,5,6

84

3,5,7

114

2,5,6,7

144

5,8

174

2,3,4,6,8

204

3,4,7,8

234

2,4,6,7,8

25

1,4,5

55

1,2,3,5,6

85

1,3,5,7

115

1,2,5,6,7

145

1,5,8

175

1,2,3,4,6,8

205

1,3,4,7,8

235

1,2,4,6,7,8

26

2,4,5

56

4,5,6

86

2,3,5,7

116

3,5,6,7

146

2,5,8

176

5,6,8

206

2,3,4,7,8

236

3,4,6,7,8

27

1,2,4,5

57

1,4,5,6

87

1,2,3,5,7

117

1,3,5,6,7

147

1,2,5,8

177

1,5,6,8

207

1,2,3,4,7,8

237

1,3,4,6,7,8

28

3,4,5

58

2,4,5,6

88

4,5,7

118

2,3,5,6,7

148

3,5,8

178

2,5,6,8

208

5,7,8

238

2,3,4,6,7,8

29

1,3,4,5

59

1,2,4,5,6

89

1,4,5,7

119

1,2,3,5,6,7

149

1,3,5,8

179

1,2,5,6,8

209

1,5,7,8

239

1,2,3,4,6,7,8

30

2,3,4,5

60

3,4,5,6

90

2,4,5,7

120

4,5,6,7

150

2,3,5,8

180

3,5,6,8

210

2,5,7,8

*240

5,6,7,8

* NOTE: code 240 is reserved for the porter switchboard

15

Operating distances with Art. 4888C
The total number of internal units with the same user code and call repetition devices (additional ringtone Art. 1229A)
connected to these internal units cannot exceed 4 (with a maximum of 2 main internal units).
Connect only one call repetition device for each internal unit.

1216

6700W
6701W
6701B

1214/2C

4888C

A MAX

B MAX

F MAX

H MAX

Comelit Art. 4577/4579 1 mm2 (Ø 1,2 mm AWG 17)

200 m
(655 feet)

200 m
(655 feet)

50 m
(165 feet)

100 m
(330 feet)

UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)

80 m
(260 feet)

150 m
(490 feet)

0,28 mm2 (Ø 0,6 mm AWG 23)

100 m
(330 feet)

150 m
(490 feet)

5m
(15 feet)

60 m
(195 feet)

0,5 mm2 (Ø 0,8 mm AWG 20)

120 m
(395 feet)

100 m
(330 feet)

25 m
(85 feet)

60 m
(195 feet)

1 mm2 (Ø 1,2 mm AWG 17)

120 m
(395 feet)

150 m
(490 feet)

50 m
(165 feet)

60 m
(195 feet)

1 mm2 (Ø 1,2 mm AWG 17)

120 m
(395 feet)

80 m
(260 feet)

50 m
(165 feet)

40 m
(130 feet)

1,5 mm2 (Ø 1,4 mm AWG 15)

150 m
(490 feet)

100 m
(330 feet)

75 m
(245 feet)

60 m
(195 feet)

2,5 mm2 (Ø 1,8 mm AWG 13)

16

60 m
(195 feet)

100 m
(330 feet)

Wiring diagrams with Art. 4888C
System with Art. 4888C: 1 Ikall series external unit
1
1216

6700W
6701W
6701B

L

L

L

L

L

C C
F 1 F 2
P
P

L

1 2 3 4 5 6

6700W/BM
6701W/BM
6701B/BM

ON

ON

12345678
S1

1234 5 67 8
S2

1214/2C

+ 6710

2628/2638

L

L

C
F
P

C
F
P

LM

OUT OUT

LM

L L
IN IN

P C S S
3 3 + -

ON

1214/2C

1234 5 67 8
S1

6700W
6701W
6701B

L

L

L

LM

OUT OUT

LM

L L
IN IN

LM

OUT OUT

LM

L L
IN IN

C C
F 1 F 2
P
P

L

1 2 3 4 5 6

6700W/BM
6701W/BM
6701B/BM

ON

ON

12345678
S1

1234 5 67 8
S2

1214/2C

+ 6710

L

L

2 3 4

4888C
L L
IN IN

L L L L L L L L
1 1 2 2 3 3 4 4

-

+

~230V~

~

1595

-

+

120-230 V

*
S
E

C
O
M

NC NO

G
N
D

P D
R O

R
T
E

V V
L
+

-

J1

L

4680KC
4680C

J2

J1
J2

33436

* Local door-opener button
Art. 4680KC manages calls originating from ONLY digital or button modules if they fall between address 1 and address 10.
SB2V/039MINIC
17

System with Art. 4888C: 2 main monitors in cascade connection
6700W
6701W
6701B

1216
L

L

CV5
L

6700W
6701W
6701B

C C
F 1 F 2
P
P

L

1 2 3 4 5 6

ON

ON

6700W/BM
6701W/BM
6701B/BM

1234 5 67 8
S1

12345678

L

C C
F 1 F 2
P
P

L

1 2 3 4 5 6

ON

6700W/BM
6701W/BM
6701B/BM

P

S2

+ 6710

ON

12345678

P

1234 5 67 8

S1

S2

+ 6710

1214/2C
L

L

OUT OUT

LM

L L LM
IN IN

SB2/A19MINIC

System with Art. 4888C: 2 main monitors and 1 secondary monitor in branch connection
6700W
6701W
6701B

1216
L

L

L

L

1 2 3 4 5 6

C C
F 1 F 2
P
P

ON

6700W/BM
6701W/BM
6701B/BM

ON

12345678

12345678

S1

S2

S

+ 6710

1214/2C
L

L

OUT OUT

LM

L L LM
IN IN

6700W
6701W
6701B

CV5
L
1 2 3 4 5 6

L

ON

6700W/BM
6701W/BM
6701B/BM

6700W
6701W
6701B

C C
F 1 F 2
P
P

12345678
S1

ON

L

1 2 3 4 5 6

P

+ 6710

C C
F 1 F 2
P
P

ON

6700W/BM
6701W/BM
6701B/BM

1234 5 67 8
S2

L

ON

1234 5 67 8

1234 5 6 78

S1

S2

P

+ 6710

1214/2C
L

L

OUT OUT

LM

L L LM
IN IN

SB2/A22MINIC

System with Art. 4888C: 2 main monitors and 1 secondary monitor in cascade connection
1216
L

L

6700W
6701W
6701B
6700W/BM
6701W/BM
6701B/BM
+ 6710

CV5
L
1 2 3 4 5 6

L

6700W
6701W
6701B

C C
F 1 F 2
P
P

ON

ON

12345678

1234 5 67 8

S1

S2

P

6700W/BM
6701W/BM
6701B/BM
+ 6710

CV5
L
1 2 3 4 5 6

L

6700W
6701W
6701B

C C
F 1 F 2
P
P

ON

ON

1234 5 67 8

12345678

S1

S2

P

6700W/BM
6701W/BM
6701B/BM

L
1 2 3 4 5 6

L

C C
F 1 F 2
P
P

ON
1234 5 67 8
S1

ON
1234 5 67 8
S2

S

+ 6710

1214/2C
L

L

OUT OUT

LM

L L LM
IN IN

SB2/A21MINIC
18

Operating distances with KIT 8461M-MB
The total number of internal units with the same user code and call repetition devices (additional ringtone Art. 1229A)
connected to these internal units cannot exceed 4 (with a maximum of 1 main internal unit and 3 secondary internal units).
Connect only one call repetition device for each internal unit.

B
1216

6700W
6701W

A

6700W
6701W

1214/2C

1209

6700W
6701W

1214/2C

A
1209
4893

4893

A MAX

B MAX

Comelit Art. 4577/4579 1 mm2 (Ø 1,2 mm AWG 17)

200 m
(655 feet)

100 m
(330 feet)

UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)

100 m
(330 feet)

60 m
(195 feet)

0,28 mm2 (Ø 0,6 mm AWG 23)

100 m
(330 feet)

60 m
(195 feet)

0,5 mm2 (Ø 0,8 mm AWG 20)

100 m
(330 feet)

60 m
(195 feet)

1 mm2 (Ø 1,2 mm AWG 17)

100 m
(330 feet)

60 m
(195 feet)

1 mm2 (Ø 1,2 mm AWG 17)

80 m
(260 feet)

40 m
(130 feet)

1,5 mm2 (Ø 1,4 mm AWG 15)

100 m
(330 feet)

60 m
(195 feet)

200 m
(660 feet)

70 m
(230 feet)

*UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)
MULTI PAIR CABLE
GREEN
GREEN / WHITE
ORANGE / WHITE
ORANGE
BLU
BLU / WHITE
BROWN / WHITE
BROWN

UTP cable with multi-cable connection: FOLLOW THE COLOURS SHOWN IN THE DIAGRAM!
19

Operating distances with Art. 1210
The total number of internal units with the same user code and call repetition devices (additional ringtone Art. 1229A)
connected to these internal units cannot exceed 4 (with a maximum of 1 main internal unit and 3 secondary internal units).
Connect only one call repetition device for each internal unit.
B

B

H

H

1216
1214/2C

1216
1214/2C

6700W
6701W
6701B

6700W
6701W
6701B

1214/2C

6700W
6701W
6701B

1214/2C

6700W
6701W
6701B

1214/2C

6700W
6701W
6701B

1214/2C

6700W
6701W
6701B

A

A

1210

C

1210

C
4681

4681

A MAX

B MAX

C MAX

H MAX

Comelit Art. 4577/4579 1 mm2 (Ø 1,2 mm AWG 17)

260
(850 feet)

130
(425 feet)

130
(425 feet)

50
(164 feet)

UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)

80
(260 feet)

40
(130 feet)

40
(130 feet)

30
(98 feet)

0,28 mm2 (Ø 0,6 mm AWG 23)

100
(328 feet)

50
(164 feet)

50
(164 feet)

30
(98 feet)

0,5 mm2 (Ø 0,8 mm AWG 20)

140
(460 feet)

70
(230 feet)

70
(230 feet)

30
(98 feet)

1 mm2 (Ø 1,2 mm AWG 17)

200
(656 feet)

100
(328 feet)

100
(328 feet)

40
(130 feet)

1,5 mm2 (Ø 1,4 mm AWG 15)

80
(260 feet)

40
(130 feet)

40
(130 feet)

30
(98 feet)

260
(850 feet)

130
(425 feet)

130
(425 feet)

50
(164 feet)

*UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)
MULTI PAIR CABLE
GREEN
GREEN / WHITE
ORANGE / WHITE
ORANGE
BLU
BLU / WHITE
BROWN / WHITE
BROWN

UTP cable with multi-cable connection: FOLLOW THE COLOURS SHOWN IN THE DIAGRAM!
20

Wiring diagrams with KIT 8461M-MB and Art.1210
KIT 8461M-MB: standard single-family system
6700W
6701W
6700W/BM
6701W/BM

L

C C
F 1 F 2
P
P

L

ON

ON

12345678
S1

1234 5 67 8
S2

L

110-240V

N
L2

30 Vdc

L2
L1

30 Vdc

L1

1209

*
SE SE NC NO C
-+

L

R
T
E

L

C
O
M

D
O

4893

MNK/039QC

* Local door-opener button

System with Art. 1210
1216

6700W
6701W
6701B

L

L

L

L

L

L

C
C
F 1 F 2
P
P

1 2 3 4 5 6

1214/2C

ON

ON

12345678
S1

1234 5 67 8
S2

LM

OUT OUT

LM

L L
IN IN

6700W
6701W
6701B

L

1214/2C
L

L

OUT OUT

L

C
C
F 1 F 2
P
P

1 2 3 4 5 6

ON

ON

12345678
S1

1234 5 67 8
S2

LM

L L LM
IN IN

110-240V

L
N
L2
L2
L1
L1

1210

*
SE SE
- +

C
O
M

NC NO

G
N
D

D
O

R
T
E

V V
L
+

-

J1

L

4681

* Local door-opener button

J2

J1
J2

33436

S2W/001MI
21

KIT 8461M-MB or system with Art. 1210: secondary monitor in branch connection
1216
L

6700W
6701W
6701B

L

1214/2C
L

L

OUT OUT

L

L

C
C
F 1 F 2
P
P

1 2 3 4 5 6

ON

6700W/BM
6701W/BM
6701B/BM

ON

1234 5 67 8
S1

1234 5 67 8
S2

S

+ 6710

LM

L L LM
IN IN

6700W
6701W
6701B

1214/2C
L

L

OUT OUT

L

L

C
C
F 1 F 2
P
P

1 2 3 4 5 6

ON

6700W/BM
6701W/BM
6701B/BM

ON

12345678
S1

1234 5 67 8
S2

P

+ 6710

LM

L L LM
IN IN

1209/1210

SB2/A24MINIC

KIT 8461M-MB or system with Art. 1210: 2 additional secondary monitors in cascade
connection

6700W
6701W
6701B
6700W/BM
6701W/BM
6701B/BM

CV5
L
1 2 3 4 5 6

+ 6710

L

C
C
F 1 F 2
P
P

ON

ON

12345678

1234 5 67 8

S1

P

S2

6700W
6701W
6701B
6700W/BM
6701W/BM
6701B/BM

CV5
L
1 2 3 4 5 6

+ 6710

L

C
C
F 1 F 2
P
P

ON

ON

1234 5 67 8

1234 5 67 8

S1

S2

S

6700W
6701W
6701B
6700W/BM
6701W/BM
6701B/BM

L
1 2 3 4 5 6

L

C
C
F 1 F 2
P
P

ON
1234 5 67 8

+ 6710

S1

ON
1234 5 67 8
S2

S

1209 / 1210

SB2/A23MINIC

Floor door call connection variant

22

CFP

CFP

L

* 20 m MAX - Use screened cable for the connection and do not run cables
near heavy inductive loads or power supply cables (230V / 400V).

L

If there are a number of door-entry phones or monitor brackets with the
same user code, connect the CFP button to one only; all the devices will ring
simultaneously.

23

3 ed. - 1rev. 04/2017
cod. 2G40001629

CERTIFIED MANAGEMENT SYSTEMS

w w w.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Language                        : it-IT
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Create Date                     : 2017:04:07 14:40:02+02:00
Metadata Date                   : 2017:04:12 16:50:11+02:00
Modify Date                     : 2017:04:12 16:50:11+02:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Instance ID                     : uuid:85824feb-7862-4343-b31e-b9f240057d20
Original Document ID            : xmp.did:F77F1174072068118083BCF93CF1794A
Document ID                     : xmp.id:1e0b0870-15b9-498d-ae69-8e23ebd0b1cc
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:98aa3605-8770-42c4-8dcf-212b2bdedcad
Derived From Document ID        : xmp.did:f3ad622f-d897-4e83-b989-e6504330af62
Derived From Original Document ID: xmp.did:F77F1174072068118083BCF93CF1794A
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2017:04:07 14:40:02+02:00
Format                          : application/pdf
Title                           : Manuale_Tecnico_posto_interno_MINI_Art.6701_Art.6700_3ED_EN_cod.2G40001629.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-3:2003
GTS PDFX Conformance            : PDF/X-3:2003
Page Count                      : 24
Creator                         : Adobe InDesign CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu