Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit

User Manual: Manual for the 69434 1/5 Horsepower, 58 PSI PSI Airbrush Compressor and Airbrush Kit 1/5 HP 58 PSI Oilless Airbrush Compressor Kit

Open the PDF directly: View PDF PDF.
Page Count: 12

Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Copyright© 2012 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual
near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and
the receipt in a safe and dry place for future reference.
Owners Manual & Safety Instructions
15e
Owners Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright© 2012 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
REV 15e
Page 2 For technical questions, please call 1-888-866-5797. Item 69434
Table of Contents
Safety ......................................................... 2
Setup .......................................................... 6
Specifications ............................................. 6
Operation .................................................... 7
Maintenance ............................................... 8
Parts List and Diagram .............................. 10
Warranty .................................................... 12
WARNING SYMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Addresses practices not related to personal injury.
SAFETY OPERATION MAINTENANCESETUP
Page 3For technical questions, please call 1-888-866-5797.Item 69434
IMPORTANT SAFETY INFORMATION
General Safety Warnings
WARNING Read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be understood by the operator that common sense
and caution are factors which cannot be built into this product, but must be supplied by the operator.
1. Work area safety
a. Keep work area clean and well lit.
Cluttered or dark areas invite accidents.
b. Do not operate the Compressor in explosive
atmospheres, such as in the presence
of flammable liquids, gases or dust.
Compressor motors produce sparks
which may ignite the dust or fumes.
c. Keep children and bystanders away
from an operating compressor.
2. Electrical safety
a. Compressor plugs must match the outlet.
Never modify the plug in any way.
Do not use any adapter plugs with grounded
compressors. Standard plugs and matching
outlets will reduce risk of electric shock.
b. Do not expose compressor to rain or wet
conditions. Water entering a compressor
will increase the risk of electric shock.
c. Do not abuse the cord. Never use the
cord for unplugging the compressor.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled
cords increase the risk of electric shock.
3. Personal safety
a. Stay alert, watch what you are doing and
use common sense when operating this
compressor. Do not use this compressor
while you are tired or under the influence
of drugs, alcohol or medication. A moment
of inattention while operating a compressor
may result in serious personal injury.
b. Use personal protective equipment.
Always wear ANSI-approved eye
protection during setup and use.
c. Prevent unintentional starting. Ensure the
switch is in the off-position before connecting
to power source or moving the compressor.
4. Compressor use and care
a. Do not use the compressor if the switch
does not turn it on and off. Any compressor
that cannot be controlled with the switch
is dangerous and must be repaired.
b. Disconnect the plug from the power source
before making any adjustments, changing
accessories, or storing the compressor.
Such preventive safety measures reduce the
risk of starting the compressor accidentally.
c. Store an idle compressor out of the reach
of children and do not allow persons
unfamiliar with the compressor or these
instructions to operate it. A compressor is
dangerous in the hands of untrained users.
d. Maintain the compressor. Keep the
compressor clean for better and safer
performance. Follow instructions for
lubricating and changing accessories.
Keep dry, clean and free from oil and grease.
Check for misalignment or binding of moving
parts, breakage of parts and any other
condition that may affect the compressors
operation. If damaged, have the compressor
repaired before use. Many accidents are
caused by a poorly maintained compressor.
e. Use the compressor in accordance with
these instructions, taking into account
the working conditions and the work to
be performed. Use of the compressor for
operations different from those intended
could result in a hazardous situation.
5. Service
a. Have your compressor serviced by a
qualified repair person using only identical
replacement parts. This will ensure that the
safety of the compressor is maintained.
SAFETYOPERATIONMAINTENANCE SETUP
Page 4 For technical questions, please call 1-888-866-5797. Item 69434
Air Compressor Safety Warnings
1. Risk of fire or explosion - do not spray flammable
liquid in a confined area or towards a hot surface.
Spray area must be well-ventilated. Do not
smoke while spraying or spray where spark or
flame is present. Arcing parts - keep compressor
at least 20 feet away from explosive vapors,
such as when spraying with a spray gun.
2. Risk of injury - do not direct air
stream at people or animals.
3. Do not use to supply breathing air.
4. Do not leave compressor unattended
for an extended period while plugged in.
Unplug compressor after working.
5. Keep compressor well-ventilated.
Do not cover compressor during use.
6. Drain Tank daily and after use.
7. Do not remove the valve cover or
adjust internal components.
8. Compressor head gets hot during operation.
Do not touch it or allow children nearby during
or immediately following operation.
9. Do not use the air hose to move the compressor.
10. The use of accessories or attachments not
recommended by the manufacturer may
result in a risk of injury to persons.
11. All air line components, including hoses, pipe,
connectors, filters, etc., must be rated for a minimum
working pressure of 150 PSI, or 150% of the
maximum system pressure, whichever is greater.
12. USE OF AN EXTENSION CORD IS NOT
RECOMMENDED. If you choose to use an
extension cord, use the following guidelines:
TABLE A: RECOMMENDED MINIMUM WIRE
GAUGE FOR EXTENSION CORDS
(120 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25′ 50′ 100′ 150′
0 – 6 18 16 16 14
6.1 – 10 18 16 Do not use.
10.1 – 12 16 16 Do not use.
12.1 – 16 14 12 Do not use.
a. Make sure your extension cord
is in good condition.
b. Be sure to use an extension cord which is heavy
enough to carry the current your product will draw.
An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating.
Table A shows the correct size to use depending
on cord length and nameplate ampere rating.
If in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.
13. Industrial applications must follow OSHA guidelines.
14. Maintain labels and nameplates on the
compressor. These carry important safety
information. If unreadable or missing, contact
Harbor Freight Tools for a replacement.
15. This product is not a toy.
Keep it out of reach of children.
16. Operate unit on level surface.
17. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
18. WARNING: The brass components of this product
contain lead, a chemical known to the State
of California to cause cancer and birth defects
or other reproductive harm. (California Health
& Safety Code § 25249.5, et seq.)
19. WARNING: The cord of this product contains
lead and/or di (2-ethylhexyl) phthalate (DEHP),
chemicals known to the State of California
to cause cancer, and birth defects or other
reproductive harm. Wash hands after handling.
(California Health & Safety Code § 25249.5, et seq.)
20. This Compressor will automatically shut
off on overload or under excessive heat.
Should this occur, turn the Power Switch to
its “OFF” position. Wait until the Compressor
cools. Then, turn the Power Switch to
its “ON” position to resume work.
21. Spray painting only. Never use this unit with
gasoline, kerosene, or any other flammable solvent.
22. Follow all precautions on materials being
propelled (paints, stains varnishes, etc.).
23. NIOSH-approved respirator and proper
ventilation are needed during use.
SAVE THESE INSTRUCTIONS.
SAFETY OPERATION MAINTENANCESETUP
Page 5For technical questions, please call 1-888-866-5797.Item 69434
Grounding
TO PREVENT ELECTRIC SHOCK AND DEATH
FROM INCORRECT GROUNDING WIRE CONNECTION:
Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.
Do not modify the power cord plug provided with the compressor.
Never remove the grounding prong from the plug. Do not use the compressor if the power cord or plug is
damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a
proper outlet installed by a qualified electrician.
110-120 VAC Grounded Compressors:
Compressors with Three Prong Plugs
1. In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current
to reduce the risk of electric shock.
This compressor is equipped with an electric cord
having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into a
matching outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
2. Do not modify the plug provided –
if it will not fit the outlet, have the proper
outlet installed by a qualified electrician.
3. Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
The conductor with insulation having an outer
surface that is green with or without yellow
stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or
plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.
4. Check with a qualified electrician or service
personnel if the grounding instructions are
not completely understood, or if in doubt as to
whether the compressor is properly grounded.
5. Use only 3-wire extension cords that have
3-prong grounding plugs and 3-pole receptacles
that accept the compressor’s plug.
6. Repair or replace damaged or worn cord immediately.
125 VAC 3-Prong Plug and Outlet
(for up to 125 VAC and up to 15 A)
Grounding
Pin
7. This compressor is intended for use on a
circuit that has an outlet that looks like the one
illustrated above in 125 VAC 3-Prong Plug
and Outlet. The compressor has a grounding
plug that looks like the plug illustrated above
in 125 VAC 3-Prong Plug and Outlet.
8. The outlet must be properly installed and grounded
in accordance with all codes and ordinances.
9. Do not use an adapter to connect this
compressor to a different outlet.
Symbology
PSI Pounds per square inch of pressure
CFM Cubic Feet per Minute flow
SCFM Cubic Feet per Minute flow
at standard conditions
NPT National pipe thread, tapered
NPS National pipe thread, straight
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
VAC Volts Alternating Current
AAmperes
SAFETYOPERATIONMAINTENANCE SETUP
Page 6 For technical questions, please call 1-888-866-5797. Item 69434
Specifications
Electrical Rating 120VAC / 60Hz / 1.1A
Motor Speed 1750 RPM
Power Cord 6′ Long
Thermal Protection Thermal automatic shut-off on overload with automatic reset
Maximum Air Pressure 58 PSI
Air Output .7 CFM @ 40 PSI
Air Outlet Size 1/8″-28 NPS
Included Accessories Airbrush, Airbrush Holder, 5cc Airbrush Cup, 22cc Glass Jar, 10 ft. Airbrush hose,
7mm wrench
Setup - Before use:
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
TO PREVENT SERIOUS INJURY
FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug
the Air Compressor from its electrical
outlet before assembling or making any
adjustments to the compressor.
Note: For additional information regarding the
parts listed in the following pages, refer to the
Assembly Diagram near the end of this manual.
Before operating, make sure the Air Compressor is set
up in a well-ventilated area, on a flat, level, solid surface
well away from any flammable objects, such as drapes.
Never paint in an area without proper ventilation,
or near possible ignition sources.
1. Connect one end of the Air Hose to the Air Outlet.
2. Connect the other end of the Air Hose to the Airbrush.
3. Connect the empty Glass Jar to the Airbrush.
4. Insert the Power Cord Plug into the nearest
120 volt, grounded, electrical outlet.
5. Turn on the power switch and inspect
the air connections for leaks.
6. Turn off and unplug the Air Compressor
then repair any leaks found.
Figure A: Functions
Power
Switch (on
end of unit)
Water Drain
Valve
Handle
Pressure
Gauge
Air Outlet
Air Hose
Airbrush
22cc Glass Jar
Connect Airbrush to Air Hose here
Moisture
Filter
SAFETY OPERATION MAINTENANCESETUP
Page 7For technical questions, please call 1-888-866-5797.Item 69434
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Compressor Area Set Up
1. Designate a work area that is clean and well-lit.
The work area must not allow access by
children or pets to prevent injury.
2. Locate the Compressor on a flat level surface to
ensure proper pump lubrication and to prevent
damage to the unit. Keep at least 12″ of space
around the unit to allow air circulation.
3. Route the power cord from the compressor
to the grounded wall outlet, along a safe path
without creating a tripping hazard or exposing
the power cord to possible damage.
General Operation
1.
Finger Lever
Nozzle & Needle
(Under the
Protective Cap)
Adjustment Screw
Airbrush Housing
Needle
Chucking Nut
Figure C
Insert the Compressor Power Cord Plug into the
nearest 120 volt, grounded, electrical outlet.
3. Fill the 22cc Glass Jar after thinning
and straining your paint properly.
NOTE: Use the proper solvent for thinning. Use
lacquer thinner for all lacquers, paint thinner for oil
based paints, and water for all latex based paints.
4. Hold the Airbrush Housing lightly in your hand and
push the tapered fitting on the lid of the 22cc Glass
Jar Assembly into the base of the Airbrush Housing.
It is held in place with friction and is not threaded.
5. Turn on the Power Switch.
6. Press the Finger Lever to begin air flow. Draw back
slowly/gently on the Finger Lever until you achieve
the air volume you need for your spray technique.
7. Continue to adjust the spray volume by using
the Finger Lever, moving it front to back. When
you have the correct spray volume, you may
fix the position using the Adjustment Screw.
8. The spray pattern size is based on the distance
between the work surface and the Airbrush Nozzle.
For extra-fine spray, remove the Protective Cap
and hold the Airbrush nearer the work surface.
9. When you are finished painting, gently release
pressure on Finger Lever (first loosening
the Adjustment Screw, if needed).
Note: If fluid blocks the Nozzle while working, move the
Needle Chucking Nut back and forth. If this does not
clear the Nozzle, try loosening the Adjustment Screw.
This will allow a longer movement for the Needle and
allow the blocked fluid to escape, clearing the Nozzle.
10. After flushing the Airbrush unit completely with
the proper solvent (Lacquer thinner if you used a
lacquer paint, water if you used a latex based paint
and paint thinner for all oil based enamels), spray
any remaining solvent through the Nozzle until clear
solvent sprays from the end of the Airbrush tip.
Note: ALL paints used with this Airbrush are
fast drying by design and can damage your
tool if they are NOT flushed immediately.
Note: The 5cc Metal Cup has two uses. It is
used for excess thinned paint, and also for
solvent when it is time to clean the Airbrush.
Note: The Metal Hook can be attached to a solid surface
and used to hang the Airbrush when it is not being used.
Note: Use this Compressor only with Airbrushes; do not
use this compressor with any other type of equipment.
11. When finished using and cleaning the Air
Compressor, turn its Power Switch off. Release
any remaining air in a safe fashion and disconnect
the Air Brush. Briefly depress the Water Drain
Valve to empty the unit of water after each use.
12. Store the Air Compressor in a clean, dry,
safe location out of reach of children
and other unauthorized people.
SAFETYOPERATIONMAINTENANCE SETUP
Page 8 For technical questions, please call 1-888-866-5797. Item 69434
Maintenance and Servicing
Procedures not specifically explained
in this manual must be performed
only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM
ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug
the Compressor from its electrical
outlet before performing any inspection,
maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM
COMPRESSOR FAILURE:
Do not use damaged equipment.
If abnormal noise or vibration occurs, have
the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
1. BEFORE EACH USE, inspect the general
condition of the Air Compressor.
Check for loose hardware, misalignment or binding
of moving parts, damaged belts, cracked or broken
parts, damaged electrical wiring, and any other
condition that may affect its safe operation.
2. AFTER USE, push the Water Drain Valve under
the Filter Cup to drain out the moisture.
Also, wipe external surfaces of the
compressor with a clean cloth.
3. Store the Air Compressor in a clean, dry,
safe location out of reach of children
and other unauthorized people.
4. AFTER EVERY 500 HOURS OF REGULAR
USE, replace Compression Ring and Inlet and
Outlet Valves. Please note: This work should
only be done by a qualified service technician.
5. WARNING! If the supply cord of this
compressor is damaged, it must be replaced
only by a qualified service technician.
SAFETY OPERATION MAINTENANCESETUP
Page 9For technical questions, please call 1-888-866-5797.Item 69434
Troubleshooting
Problem Possible Causes Likely Solutions
The motor does
not work.
1. No electrical power.
2. Damaged power cord.
3. Electrical wiring within
the unit is defective.
4. Power switch is defective.
1. Plug the power cord into a working,
120VAC, grounded, electrical outlet.
2. Have a qualified service technician
replace the power cord.
3. Have a qualified service technician
replace electric wiring.
4. Have a qualified service technician
replace power switch.
The motor runs,
but it makes
irregular noises or
a knocking noise.
1. Bearing is loose or damaged.
2. Screws in the connection
rod are loose.
1. Have a qualified service technician replace the bearing.
2. Tighten the screws, or replace them if necessary.
Not enough
pressure when
painting or spraying.
1. Loose air connection(s).
2. Air hose is damaged.
3. Screws on cylinder cover are loose.
1. Check all air connections, and tighten them if necessary
2. Replace air hose.
3. Tighten screws.
Poor spray pattern. 1. Loose air connections(s).
2. The paint is too thick.
3. The Airbrush nozzle is plugged or dirty.
1. Check all air connections, and
tighten them if necessary.
2. Add paint thinner and mix thoroughly.
3. Clean or change the nozzle.
Motor runs
properly, but no air
pressure or lack
of air delivery.
1. Valve plate is loose or out of place.
2. Retainer ring is damaged after
excessive use at high pressure.
1. Open the front cover and make sure the valve plate is
in the proper position. Tighten the screws if necessary.
2. Have a qualified service technician
replace the retainer ring.
Follow all safety precautions whenever diagnosing or servicing the compressor.
Disconnect power supply before service.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
SAFETYOPERATIONMAINTENANCE SETUP
Page 10 For technical questions, please call 1-888-866-5797. Item 69434
Parts List and Diagram
Compressor Parts List and Assembly Diagram
Part Description Qty
1 Power Switch 1
2 Front Cover 1
3 Power Cord 1
4 Capacitor 1
5 Rear Housing 1
6 Screw 4
7 Stator 1
8 Bearing 1
9 Rotor 11
10 Bearing 1
11 Foot 1
12 Front Housing 1
13 O-Ring 1
14 Cylinder Block 1
15 O-Ring 1
16 O-Ring 1
17 Pressure Switch 1
Part Description Qty
18 Handle 1
19 Screw 4
20 Cylinder Head 1
21 Connector 1
22 Moisture Filter and Pressure Gauge 1
23 Connector 1
24 Counterweight 1
25 Bearing 1
26 Connecting Rod 1
27 Snap Ring 1
28 Compression Ring 1
29 Piston 1
30 Valve Plate 1
31 Screw 1
32 Sleeve 1
33 Back Cover 1
SAFETY OPERATION MAINTENANCESETUP
Page 11For technical questions, please call 1-888-866-5797.Item 69434
Part Description
1A Protective Cap
2A Air Cap
3A Nozzle
4A Air Cap Body
5A O-Ring
6A Packing
7A Packing Nut
8A Housing
9A Adjustment Screw
10A Finger Lever
11A Rocker
12A Stopper
13A Needle Chucking Guide
14A Spring
15A Spring Case
16A Needle Chucking Nut
Part Description
17A Handle
18A Needle
19A O-Ring
20A Valve Rod
21A O-Ring
22A Spring
23A Valve Screw
24A Valve Body
25A Hose Connector Nut
26A O-Ring
27A Hose Connector
28A Cup 5cc
29A Wrench 7mm
30A Hanger
31A Glass Jar Assembly 22cc
32A Air Hose (not shown)
Airbrush Parts List and Assembly Diagram
17
18
4
36
2
1
19
9
10
8
11
21
20
22
23
31
28
29
30
5
24
25
26
27
16
7
14
12 13
15
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only,
and are not available individually as replacement parts.
Note: When ordering parts from this assembly diagram,
include the suffix ″A″ after the number.
SAFETYOPERATIONMAINTENANCE SETUP
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards,
and warrants to the original purchaser that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries
to persons or property, or for incidental, contingent, special or consequential damages arising from the use of
our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges
prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may
elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will
return repaired products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • 1-888-866-5797
Page 1 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 2 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 3 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 4 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 5 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 6 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 7 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 8 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 9 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 10 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 11 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit
Page 12 of 12 - Manual For The 69434 1/5 Horsepower, 58 PSI Airbrush Compressor And Kit

Navigation menu