Manual For The 69669 1.8 Horsepower, 26 Gallon, 150 PSI Oilless Air Compressor
User Manual: Manual for the 69669 1.8 Horsepower, 26 Gallon, 150 PSI PSI Oilless Air Compressor 26 gal. 1.8 HP 150 PSI Oilless Air Compressor
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
Owner’s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. 17 GAL oilless air compressor 26 GAL oilless air compressor Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible. Copyright© 2012 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included. Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. 17f Table of contents Safety ......................................................... 2 Maintenance .............................................. 11 Setup .......................................................... 6 Parts List and Diagram .............................. 14 Specifications ............................................. 6 Warranty .................................................... 16 SAFETy Operation ................................................... 10 SETUp WARNING SyMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. OpERATION Addresses practices not related to personal injury. MAINTENANcE Page 2 For technical questions, please call 1-888-866-5797. Item 69666 69669 IMpORTANT SAFETy INFORMATION WARNING Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. 4. compressor use and care c. Keep children and bystanders away from an operating compressor. 2. Electrical safety a. compressor plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with grounded compressors. Standard plugs and matching outlets will reduce risk of electric shock. b. Do not expose compressor to rain or wet conditions. Water entering a compressor will increase the risk of electric shock. c. Do not abuse the cord. Never use the cord for unplugging the compressor. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. 3. personal safety a. Stay alert, watch what you are doing and use common sense when operating this compressor. Do not use this compressor while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating a compressor may result in serious personal injury. b. Use personal protective equipment. Always wear ANSI-approved eye protection during setup and use. c. prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source or moving the compressor. Item 69666 69669 b. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the compressor. Such preventive safety measures reduce the risk of starting the compressor accidentally. c. Store an idle compressor out of the reach of children and do not allow persons unfamiliar with the compressor or these instructions to operate it. A compressor is dangerous in the hands of untrained users. d. Maintain the compressor. Keep the compressor clean for better and safer performance. Follow instructions for lubricating and changing accessories. Keep dry, clean and free from oil and grease. check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the compressor’s operation. If damaged, have the compressor repaired before use. Many accidents are caused by a poorly maintained compressor. e. Use the compressor in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the compressor for operations different from those intended could result in a hazardous situation. SETUp b. Do not operate the compressor in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Compressor motors produce sparks which may ignite the dust or fumes. a. Do not use the compressor if the switch does not turn it on and off. Any compressor that cannot be controlled with the switch is dangerous and must be repaired. OpERATION a. Keep work area clean and well lit. Cluttered or dark areas invite accidents. 5. Service a. Have your compressor serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the compressor is maintained. For technical questions, please call 1-888-866-5797. Page 3 MAINTENANcE 1. Work area safety SAFETy General Safety Warnings Air compressor Safety Warnings SAFETy 1. Risk of fire or explosion - do not spray flammable liquid in a confined area or towards a hot surface. Spray area must be well-ventilated. Do not smoke while spraying or spray where spark or flame is present. Arcing parts - keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun. 2. Risk of bursting - do not adjust regulator higher than marked maximum pressure of attachment. 3. Risk of injury - do not direct air stream at people or animals. 14. USE OF AN EXTENSION CORD IS NOT RECOMMENDED. If you choose to use an extension cord, use the following guidelines: TABLE A: REcOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION cORDS (120 VOLT) NAMEpLATE AMpERES (at full load) EXTENSION cORD LENGTH 25′ 50′ 100′ 150′ 0–6 18 16 16 14 4. Do not use to supply breathing air. 6.1 – 10 18 16 Do not use. 10.1 – 12 16 16 Do not use. 5. Do not leave compressor unattended for an extended period while plugged in. Unplug compressor after working. 12.1 – 16 14 12 Do not use. SETUp 6. Keep compressor well-ventilated. Do not cover compressor during use. 7. Drain Tank daily and after use. Internal rust causes tank failure and explosion. 8. Do not remove the valve cover or adjust internal components. 9. Compressor head gets hot during operation. Do not touch it or allow children nearby during or immediately following operation. 10. Do not use the air hose to move the compressor. OpERATION 11. Release the pressure in the storage tank before moving. 12. The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons. 13. All air line components, including hoses, pipe, connectors, filters, etc., must be rated for a minimum working pressure of 150 PSI, or 150% of the maximum system pressure, whichever is greater. a. Make sure your extension cord is in good condition. b. Be sure to use an extension cord which is heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table A shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. 15. Industrial applications must follow OSHA guidelines. 16. Maintain labels and nameplates on the compressor. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement. 17. This product is not a toy. Keep it out of reach of children. 18. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure. SAVE THESE INSTRUcTIONS. MAINTENANcE Page 4 For technical questions, please call 1-888-866-5797. Item 69666 69669 TO pREVENT ELEcTRIc SHOcK AND DEATH FROM INcORREcT GROUNDING WIRE cONNEcTION: check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the compressor. Never remove the grounding prong from the plug. Do not use the compressor if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician. SAFETy Grounding 110-120 VAc Grounded compressors: compressors with Three prong plugs 2. Do not modify the plug provided – if it will not fit the outlet, have the proper outlet installed by a qualified electrician. 3. Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipmentgrounding conductor to a live terminal. 4. Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded. 5. Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the compressor’s plug. SETUp 6. Repair or replace damaged or worn cord immediately. Grounding pin 125 VAc 3-prong plug and Outlet (for up to 125 VAc and up to 15 A) 7. This compressor is intended for use on a circuit that has an outlet that looks like the one illustrated above in 125 VAc 3-prong plug and Outlet. The compressor has a grounding plug that looks like the plug illustrated above in 125 VAc 3-prong plug and Outlet. 8. The outlet must be properly installed and grounded in accordance with all codes and ordinances. OpERATION 1. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This compressor is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. 9. Do not use an adapter to connect this compressor to a different outlet. pSI Pounds per square inch of pressure Double Insulated cFM Cubic Feet per Minute flow Canadian Standards Association ScFM Cubic Feet per Minute flow at standard conditions Underwriters Laboratories, Inc. NpT National pipe thread, tapered NpS National pipe thread, straight Item 69666 69669 VAc A MAINTENANcE Symbology Volts Alternating Current Amperes For technical questions, please call 1-888-866-5797. Page 5 Specifications Model Electrical Rating 69666 120VAC / 60Hz / 13.5A 1/ ″ 4 SAFETy Air Outlet Size Air Pressure 69669 Shut-off Restart Air Tank Capacity Air Flow Capacity Sound Level -18 NPT 150 PSI 125 PSI 26 Gallons 17 Gallons 226892 4 SCFM @ 90 PSI 5 SCFM @ 40 PSI 91 dB @ 3′ Instructions for putting into use Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. SETUp TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION: Turn the power Switch “OFF” and unplug the Air compressor from its electrical outlet before assembling or making any adjustments to the compressor. Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual. Functions Handle power Switch OpERATION Output Air pressure Gauge Tank Air pressure Gauge Tank Safety Valve Regulator Knob Air Output MAINTENANcE Wheel Page 6 For technical questions, please call 1-888-866-5797. Item 69666 69669 1. Break in the new Air Compressor as follows: a. Turn the Power Switch off and unplug the unit. Insert a male coupler (sold separately) into the female Quick Coupler and fully open all regulators and valves. b. Plug in the Power Cord. c. Turn the Power Switch ON. d. Let the unit run for 30 minutes. Air will expel freely through the Coupler. e. Turn the Power Switch OFF. Note: An in-line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured. The shutoff valve should be a ball valve because it can be closed quickly. 3. Depending on the tool which you will be using with this compressor, you may need to incorporate additional components, such as an in-line oiler, a filter, or a dryer (all sold separately), as shown on Figure B on page 8 and Figure C on page 9. Consult your air tool’s manual for needed accessories. MAINTENANcE OpERATION SETUp f. Unplug the Power Cord and remove the male coupler. 2. Connect a regulator valve, an inline shut off valve and a 1/4″ NPT air hose to the Quick Coupler (all sold separately). The air hose must be long enough to reach the work area with enough extra length to allow free movement while working. SAFETy Setup Item 69666 69669 For technical questions, please call 1-888-866-5797. Page 7 For technical questions, please call 1-888-866-5797. Description Non-lubricated Tools A Air Hose Filter Regulator Lubricator (optional) Coupler and Plug Leader Hose (optional) Air Cleaner / Dryer (optional) Air Adjusting Valve (optional) MAINTENANcE A B C D E F G H OpERATION Lubricated Tools B B C C A A E E F H Connects air to tool Prevents dirt and condensation from damaging tool or workpiece Adjusts air pressure to tool For air tool lubrication Provides quick connection and release Increases coupler life Prevents water vapor from damaging workpiece For fine tuning airflow at tool G D Function SETUp Figure B: portable Air Supply Setup SAFETy Page 8 Item 69666 69669 Item 69666 69669 For technical questions, please call 1-888-866-5797. Page 9 A B C D E F G H I J K L M N O F Description F E I I J OpERATION N K J H Function H L L M O SETUp SAFETy For noise and vibration reduction Secures air compressor in place Isolates sections of system for maintenance For vibration reduction Distributes air to branch lines To drain moisture from system Brings air to point of use Connects air to tool Prevents dirt and condensation from damaging tool or workpiece Adjusts air pressure to tool For air tool lubrication Provides quick connection and release Increases coupler life Prevents water vapor from damaging workpiece For fine tuning airflow at tool Non-lubricated Tools C C Vibration Pads Anchor Bolts Ball Valve Isolation Hose Main Air Line - 3/4″ minimum recommended Ball Valve Branch Air Line -1/2″ minimum recommended Air Hose Filter Regulator Lubricator (optional) Coupler and Plug Leader Hose (optional) Air Cleaner / Dryer (optional) Air Adjusting Valve (optional) B A MAINTENANcE B A C D G Lubricated Tools Slope Figure c: Stationary Air Supply Setup F Operating Instructions Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. SAFETy compressor Area Set Up 1. Designate a work area that is clean and well-lit. The work area must not allow access by children or pets to prevent injury. 2. Locate the Compressor on a flat level surface to ensure proper pump lubrication and to prevent damage to the unit. Keep at least 12″ of space around the unit to allow air circulation. 3. Route the power cord from the compressor to the grounded wall outlet, along a safe path without creating a tripping hazard or exposing the power cord to possible damage. General Operation SETUp 1. Close the Drain Valve. 2. Close the in-line Shutoff Valve between the compressor and the air hose. 3. Plug the Air Compressor Power Cord into a grounded 120 VAC electrical outlet. 4. Turn the Power Switch ON. 5. Allow the Air Compressor to build up pressure until it cycles off. OpERATION Note: At the beginning of the day’s first use of the Air Compressor, check for air leaks by applying soapy water to connections while the Air Compressor is pumping and after pressure cutout. Look for air bubbles. If air bubbles are present at connections, tighten connections. Do not use the Air Compressor unless all connections are air tight, the extra air leaking out will cause the compressor to operate too often, increasing wear on the compressor. MAINTENANcE Note: As long as the Power Switch is ON, the operation of the Air Compressor is automatic, controlled by an internal pressure switch. The Compressor will turn on automatically when the air pressure drops to 125 PSI, and will turn off automatically when the air pressure reaches 150 PSI. WARNING! TO pREVENT SERIOUS INJURy AND DEATH FROM EXpLOSION: Do not adjust the internal pressure switch. Any change to the automatic pressure levels may cause excess pressure to accumulate, causing a hazardous situation. 6. Adjust the Regulator Knob so that the air output is enough to properly power the tool, but the output will not exceed the tool’s maximum air pressure at any time. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease pressure. Adjust the pressure gradually, while checking the air output gauge to set the pressure. 7. Make sure the air tool’s throttle or switch is in the off position. Connect the air tool to the air hose. 8. Open the in-line Shutoff Valve. 9. Use the air tool as needed. 10. After the job is complete, turn the Power Switch OFF. 11. Unplug the Air Compressor. 12. Close the in-line Shutoff Valve. 13. Bleed air from the tool then disconnect the tool. 14. Open the Drain Valve lever, at the bottom of the Tank to release any built-up moisture and the internal tank pressure. Close the valve after moisture has drained out. Do not remove the Drain Valve. 15. Clean, then store the Air Compressor indoors. Emergency Depressurization If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF. Then, pull on the ring on the Safety Valve to quickly release stored air pressure. Page 10 For technical questions, please call 1-888-866-5797. Item 69666 69669 Automatic Shut off System 2. Possible causes of repeated automatic shut off of the compressor are: a. Shut off all tools. a. Using an extension cord that is too long or narrow; b. Wait until the Compressor cools down (about 10 minutes); c. If the unit does not start up again on its own, move the Power Switch to OFF position, then back to ON; b. An air leak or open hose causing the compressor to cycle too often and build up heat. 3. Correct any issues before further use to avoid damage to the compressor. SAFETy 1. If the Compressor automatically shuts off before reaching its normal cutoff pressure: d. Resume operation. Maintenance and Servicing SETUp procedures not specifically explained in this manual must be performed only by a qualified technician. TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION: Turn the power Switch “OFF” and unplug the compressor from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. TO pREVENT SERIOUS INJURy FROM cOMpRESSOR FAILURE: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use. 1. BEFORE EAcH USE, inspect the general condition of the air compressor. Check for: • loose hardware, • misalignment or binding of moving parts, • cracked or broken parts, • damaged electrical wiring, and • any other condition that may affect its safe operation. 2. AFTER USE, wipe external surfaces of the compressor with a damp cloth. Check for air leaks by applying soapy water to joints while the Air Compressor is pressurized and looking for air bubbles. 3. WARNING! If the supply cord of this compressor is damaged, it must be replaced only by a qualified service technician. OpERATION cleaning, Maintenance, and Lubrication Maintenance Schedule Following are general guidelines for maintenance checks of the Air Compressor. Daily: MAINTENANcE Note: The environment in which the compressor is used, and the frequency of use can affect how often you will need to check the Air Compressor components and perform maintenance procedures. Weekly: a. Make sure all nuts and bolts are tight. b. Drain moisture from air tank. c. Check for abnormal noise or vibration. d. Check for air leaks. Inspect Air Filter. Monthly: Inspect Safety Valve. e. Wipe off any oil or dirt from the compressor. Item 69666 69669 For technical questions, please call 1-888-866-5797. Page 11 Draining Moisture from the Tank The Drain Valve is located under the Tank. It must be used daily to release all trapped air and moisture from the Tank. This will eliminate condensation which can cause tank corrosion. 1. Turn the Power switch of the compressor off. SAFETy 2. Place a collection pan under the Drain Valve. 3. Turn Drain Valve lever downward to release air inside. 4. When all the pressure and moisture is released, close the Drain Valve. Air Filter Maintenance Check the Air Filter weekly to see if it needs replacement. If working in dirty environments, you may need to replace the filter more often. 1. Remove the Cover. 3. Replace with a new Air Filter. 2. Remove the Air Filter. 4. Replace the Cover. Troubleshooting SETUp problem Compressor does not start or restart possible causes Likely Solutions 1. Tank(s) already pressurized. 1. No problem. Compressor will start when needed. 2. Power cord not plugged in properly. 2. Check that cord is plugged in securely. 3. Incorrect power supply. 3. Check that circuit matches compressor requirements. 4. No power at outlet. 4. Reset circuit breaker, or have outlet serviced by a qualified technician. 5. Thermal overload switch tripped. 5. Turn off Compressor and wait for it to cool down. Resume operation. 6. Building power supply circuit tripped or blown fuse. 6. Reset circuit or replace fuse. Check for low voltage conditions. It may be necessary to disconnect other electrical appliances from the circuit or move the compressor to its own circuit. OpERATION 7. Cord wire size is too small or cord is too 7. Use larger diameter or shorter extension cord or long to properly power compressor. eliminate extension cord. See Recommended Wire Gauge for Extension Cords in Safety section. Compressor builds pressure too slowly Compressor not building enough air pressure MAINTENANcE 8. Compressor needs service. 8. Have unit inspected by a qualified technician. 1. Incorrect power supply. 1. Check that circuit matches compressor requirements. 2. Working environment too cold. 2. Move compressor to a warmer location. 3. Safety valve leaking. 3. Listen for air leaking from valve. If leaking, replace with identical valve with same rating. DO NOT SEAL OR TAMpER WITH SAFETy VALVE. 4. Loose fittings. 4. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. 1. Air filters need cleaning/replacing. 1. Check inlet and outlet filters. Clean and/or replace as needed. 2. Check Valve needs service. 2. Have technician clean or replace, as needed. 3. Compressor not large enough for job. 3. Check if accessory CFM is met by Compressor. If Compressor cannot supply enough air flow (CFM), you need a larger Compressor. 4. Loose fittings. 4. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. 5. Hose or hose connections too narrow. 5. Replace with wider hose and/or hose connections. 6. High altitude reducing air output. 6. Higher altitudes require compressors with greater output. Follow all safety precautions whenever diagnosing or servicing the compressor. Disconnect power supply before service. Page 12 For technical questions, please call 1-888-866-5797. Item 69666 69669 Troubleshooting (cont.) Likely Solutions 1. Air filters need cleaning/replacing. 1. Check inlet and outlet filters. Clean and/or replace as needed. 2. Unusually dusty environment. 2. Clean and/or replace filters more often or move unit to cleaner environment. 3. Extension cord used. 3. Eliminate extension cord. 4. Unit not on level surface. 4. Reposition unit on a level surface. 1. Loose fittings. 1. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. 2. Compressor not large enough for job. 2. Check if accessory CFM is met by Compressor. If Compressor doesn’t reach accessory CFM, you need a larger Compressor. 1. Loose or damaged belt guard. 1. Replace belt guard. 2. Loose fittings. 2. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. 3. Unit not on level surface. 3. Reposition unit on a level surface. Moisture in discharge air Too much moisture in air. Install inline air filter/dryer, and/or relocate to less humid environment. Safety Valve “pops” Safety valve needs service. Pull on test ring of safety valve. If it still pops, replace. Air leaks from pump or fittings Loose fittings. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten. Air leaks from tank Defective or rusted tank. Have tank replaced by a qualified technician. Drain moisture from tank daily to prevent future corrosion. Compressor starts and stops excessively Excessive noise SAFETy Overheating possible causes SETUp problem pLEASE READ THE FOLLOWING cAREFULLy MAINTENANcE THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. OpERATION Follow all safety precautions whenever diagnosing or servicing the compressor. Disconnect power supply before service. Item 69666 69669 For technical questions, please call 1-888-866-5797. Page 13 parts List and Diagram parts List SAFETy part SETUp OpERATION MAINTENANcE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Description Bolt M6x35 Spring Washer M6 Cylinder Head Exhaust Elbow Valve Plate Inlet Valve Reed Outlet Valve Reed Limiter Inlet Valve Reed Cover Bolt M4x8 Spring Washer M4 Valve Plate Upper O-Ring Valve Plate Lower O-Ring Cylinder Bolt M6x16 Connecting Rod Cover Piston Ring Connecting Rod Nut M5 Spring Washer M5 Screw M5x25 Bearing 6203 Crank Bolt M6x40 Fan Bolt M6x16 Washer M6 Inner Teeth Washer M8 Nut M8 Bolt M5x195 Washer M5 Spring Washer M5 Nut M5 Run Capacitor Bolt M3x6 Spring Washer M3 Washer M3 Start Capacitor Crankcase Motor Cover Rotor Stator Washer 203 Rear Seat Centrifugal Switch Capacitor Bracket Bolt M5x12 Bolt M4x6 Qty part 4 5 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 2 2 4 8 8 4 1 4 4 4 1 1 1 1 1 1 1 1 1 4 1 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 Description Qty Washer Ø4 Bolt M5x6 Ground Symbol Overload Protector Strain Relief Grommet Bolt M8x25 Washer M8 Spring Washer M8 Nut M8 Front Shroud Rear Shroud Shroud Cover Bolt M5x15 Screw ST4.0x25 Screw ST4.2x30 Screw ST3.8x12 Pressure Switch Strain Relief Connector 1/4″ NPT x 30 Pressure Gauge (270 PSI 1/4″ NPT) Pressure Gauge (270 PSI 1/8″ NPT) Regulator Quick Coupler Safety Valve Connector 1/4″ NPT x 48 Check Valve Brass Washer Pressure Tube Compression Nut Ø3/8″ Relief Tube Relief Nut Power Cord Cable Connector U Cable Connector O Axle Wheel 8" Rubber Foot Bolt M8x20 Drain Valve (Not shown) Tank Handle Bolt M6x20 Rivet Nut M6 Washer M6 Air Filter Handle Grip 1 1 1 1 1 2 4 12 6 8 1 1 1 4 1 2 4 1 2 1 1 1 1 1 1 1 1 2 1 2 1 1 1 2 1 2 2 2 2 1 1 1 4 4 4 1 1 Record product’s Serial Number Here: Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Parts may not be interchangeable. Specify number when ordering. Page 14 For technical questions, please call 1-888-866-5797. Item 69666 69669 Assembly Diagram 1 94 2 SAFETy 3 12 35 36 37 7 9 10 13 15 6 42 23 22 5149 52 54 50 70 69 66 61 60 63 48 53 41 55 56 57 58 2 24 20 21 26 44 40 22 27 45 43 39 32 30 32 33 25 19 31 47 22 31 17 18 47 32 38 14 16 34 28 29 46 SETUp 5 4 59 65 75 74 67 73 68 71 72 90 64 OpERATION 10 11 8 95 62 93 76 78 92 91 MAINTENANcE 77 89 79 80 83 81 82 58 56 57 58 84 Item 69666 69669 85 86 56 87 For technical questions, please call 1-888-866-5797. Page 15 Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 3491 Mission Oaks Blvd. • pO Box 6009 • camarillo, cA 93011 • 1-888-866-5797
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 48 Producer : Mac OS X 10.11.6 Quartz PDFContext Create Date : 2017:06:13 23:04:48Z Modify Date : 2017:06:13 23:04:48ZEXIF Metadata provided by EXIF.tools