Manual For The 69669 1.8 Horsepower, 26 Gallon, 150 PSI Oilless Air Compressor

User Manual: Manual for the 69669 1.8 Horsepower, 26 Gallon, 150 PSI PSI Oilless Air Compressor 26 gal. 1.8 HP 150 PSI Oilless Air Compressor

Open the PDF directly: View PDF PDF.
Page Count: 48

DownloadManual For The 69669 1.8 Horsepower, 26 Gallon, 150 PSI Oilless Air Compressor
Open PDF In BrowserView PDF
Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,

operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.

17 GAL oilless
air compressor

26 GAL oilless
air compressor

Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright© 2012 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.

Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

17f

Table of contents
Safety ......................................................... 2

Maintenance .............................................. 11

Setup .......................................................... 6

Parts List and Diagram .............................. 14

Specifications ............................................. 6

Warranty .................................................... 16

SAFETy

Operation ................................................... 10

SETUp

WARNING SyMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

OpERATION

Addresses practices not related to personal injury.

MAINTENANcE
Page 2

For technical questions, please call 1-888-866-5797.

Item 69666 69669

IMpORTANT SAFETy INFORMATION
WARNING Read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be understood by the operator that common sense
and caution are factors which cannot be built into this product, but must be supplied by the operator.
4. compressor use and care

c. Keep children and bystanders away
from an operating compressor.
2. Electrical safety
a. compressor plugs must match the outlet.
Never modify the plug in any way.
Do not use any adapter plugs with grounded
compressors. Standard plugs and matching
outlets will reduce risk of electric shock.
b. Do not expose compressor to rain or wet
conditions. Water entering a compressor
will increase the risk of electric shock.
c. Do not abuse the cord. Never use the
cord for unplugging the compressor.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled
cords increase the risk of electric shock.
3. personal safety
a. Stay alert, watch what you are doing and
use common sense when operating this
compressor. Do not use this compressor
while you are tired or under the influence
of drugs, alcohol or medication. A moment
of inattention while operating a compressor
may result in serious personal injury.
b. Use personal protective equipment.
Always wear ANSI-approved eye
protection during setup and use.
c. prevent unintentional starting. Ensure the
switch is in the off-position before connecting
to power source or moving the compressor.

Item 69666 69669

b. Disconnect the plug from the power source
before making any adjustments, changing
accessories, or storing the compressor.
Such preventive safety measures reduce the
risk of starting the compressor accidentally.
c. Store an idle compressor out of the reach
of children and do not allow persons
unfamiliar with the compressor or these
instructions to operate it. A compressor is
dangerous in the hands of untrained users.
d. Maintain the compressor. Keep the
compressor clean for better and safer
performance. Follow instructions for
lubricating and changing accessories.
Keep dry, clean and free from oil and grease.
check for misalignment or binding of moving
parts, breakage of parts and any other
condition that may affect the compressor’s
operation. If damaged, have the compressor
repaired before use. Many accidents are
caused by a poorly maintained compressor.
e. Use the compressor in accordance with
these instructions, taking into account
the working conditions and the work to
be performed. Use of the compressor for
operations different from those intended
could result in a hazardous situation.

SETUp

b. Do not operate the compressor in explosive
atmospheres, such as in the presence
of flammable liquids, gases or dust.
Compressor motors produce sparks
which may ignite the dust or fumes.

a. Do not use the compressor if the switch
does not turn it on and off. Any compressor
that cannot be controlled with the switch
is dangerous and must be repaired.

OpERATION

a. Keep work area clean and well lit.
Cluttered or dark areas invite accidents.

5. Service
a. Have your compressor serviced by a
qualified repair person using only identical
replacement parts. This will ensure that the
safety of the compressor is maintained.

For technical questions, please call 1-888-866-5797.

Page 3

MAINTENANcE

1. Work area safety

SAFETy

General Safety Warnings

Air compressor Safety Warnings

SAFETy

1. Risk of fire or explosion - do not spray
flammable liquid in a confined area or towards a
hot surface. Spray area must be well-ventilated.
Do not smoke while spraying or spray where
spark or flame is present. Arcing parts - keep
compressor at least 20 feet away from explosive
vapors, such as when spraying with a spray gun.
2. Risk of bursting - do not adjust regulator higher
than marked maximum pressure of attachment.
3. Risk of injury - do not direct air
stream at people or animals.

14. USE OF AN EXTENSION CORD IS NOT
RECOMMENDED. If you choose to use an
extension cord, use the following guidelines:
TABLE A: REcOMMENDED MINIMUM WIRE
GAUGE FOR EXTENSION cORDS
(120 VOLT)

NAMEpLATE
AMpERES
(at full load)

EXTENSION cORD
LENGTH
25′
50′
100′ 150′

0–6

18

16

16

14

4. Do not use to supply breathing air.

6.1 – 10

18

16

Do not use.

10.1 – 12

16

16

Do not use.

5. Do not leave compressor unattended
for an extended period while plugged in.
Unplug compressor after working.

12.1 – 16

14

12

Do not use.

SETUp

6. Keep compressor well-ventilated.
Do not cover compressor during use.
7. Drain Tank daily and after use. Internal rust causes
tank failure and explosion.
8. Do not remove the valve cover or
adjust internal components.
9. Compressor head gets hot during operation.
Do not touch it or allow children nearby
during or immediately following operation.
10. Do not use the air hose to move the compressor.

OpERATION

11. Release the pressure in the
storage tank before moving.
12. The use of accessories or attachments not
recommended by the manufacturer may
result in a risk of injury to persons.
13. All air line components, including hoses, pipe,
connectors, filters, etc., must be rated for a minimum
working pressure of 150 PSI, or 150% of the
maximum system pressure, whichever is greater.

a. Make sure your extension cord
is in good condition.
b. Be sure to use an extension cord which
is heavy enough to carry the current your
product will draw. An undersized cord will
cause a drop in line voltage resulting in loss
of power and overheating. Table A shows the
correct size to use depending on cord length
and nameplate ampere rating. If in doubt,
use the next heavier gauge. The smaller
the gauge number, the heavier the cord.
15. Industrial applications must follow OSHA guidelines.
16. Maintain labels and nameplates on the
compressor. These carry important safety
information. If unreadable or missing, contact
Harbor Freight Tools for a replacement.
17. This product is not a toy.
Keep it out of reach of children.
18. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.

SAVE THESE INSTRUcTIONS.
MAINTENANcE
Page 4

For technical questions, please call 1-888-866-5797.

Item 69666 69669

TO pREVENT ELEcTRIc SHOcK AND DEATH
FROM INcORREcT GROUNDING WIRE cONNEcTION:
check with a qualified electrician if you are in doubt as to whether the outlet is properly
grounded. Do not modify the power cord plug provided with the compressor.
Never remove the grounding prong from the plug. Do not use the compressor if the power cord or plug is
damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have
a proper outlet installed by a qualified electrician.

SAFETy

Grounding

110-120 VAc Grounded compressors:
compressors with Three prong plugs

2. Do not modify the plug provided –
if it will not fit the outlet, have the proper
outlet installed by a qualified electrician.
3. Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
The conductor with insulation having an outer
surface that is green with or without yellow
stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or
plug is necessary, do not connect the equipmentgrounding conductor to a live terminal.
4. Check with a qualified electrician or service
personnel if the grounding instructions are
not completely understood, or if in doubt as to
whether the compressor is properly grounded.
5. Use only 3-wire extension cords that have
3-prong grounding plugs and 3-pole receptacles
that accept the compressor’s plug.

SETUp

6. Repair or replace damaged or
worn cord immediately.

Grounding
pin

125 VAc 3-prong plug and Outlet
(for up to 125 VAc and up to 15 A)
7. This compressor is intended for use on a
circuit that has an outlet that looks like the one
illustrated above in 125 VAc 3-prong plug
and Outlet. The compressor has a grounding
plug that looks like the plug illustrated above
in 125 VAc 3-prong plug and Outlet.
8. The outlet must be properly installed and grounded
in accordance with all codes and ordinances.

OpERATION

1. In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric shock.
This compressor is equipped with an electric
cord having an equipment-grounding conductor
and a grounding plug. The plug must be
plugged into a matching outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.

9. Do not use an adapter to connect this
compressor to a different outlet.

pSI

Pounds per square inch of pressure

Double Insulated

cFM

Cubic Feet per Minute flow

Canadian Standards Association

ScFM

Cubic Feet per Minute flow
at standard conditions

Underwriters Laboratories, Inc.

NpT

National pipe thread, tapered

NpS

National pipe thread, straight

Item 69666 69669

VAc
A

MAINTENANcE

Symbology

Volts Alternating Current
Amperes

For technical questions, please call 1-888-866-5797.

Page 5

Specifications
Model
Electrical Rating

69666

120VAC / 60Hz / 13.5A
1/ ″
4

SAFETy

Air Outlet Size
Air Pressure

69669

Shut-off
Restart

Air Tank Capacity
Air Flow Capacity
Sound Level

-18 NPT

150 PSI
125 PSI
26 Gallons

17 Gallons

226892

4 SCFM @ 90 PSI
5 SCFM @ 40 PSI
91 dB @ 3′

Instructions for putting into use
Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.

SETUp

TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION:
Turn the power Switch “OFF” and unplug the Air compressor from its electrical
outlet before assembling or making any adjustments to the compressor.
Note: For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.

Functions
Handle

power Switch

OpERATION

Output Air
pressure
Gauge

Tank Air
pressure
Gauge

Tank
Safety Valve

Regulator
Knob

Air
Output

MAINTENANcE

Wheel

Page 6

For technical questions, please call 1-888-866-5797.

Item 69666 69669

1. Break in the new Air Compressor as follows:
a. Turn the Power Switch off and unplug the unit.
Insert a male coupler (sold separately)
into the female Quick Coupler and
fully open all regulators and valves.
b. Plug in the Power Cord.
c. Turn the Power Switch ON.
d. Let the unit run for 30 minutes.
Air will expel freely through the Coupler.
e. Turn the Power Switch OFF.

Note: An in-line shutoff ball valve is an important
safety device because it controls the air supply even
if the air hose is ruptured. The shutoff valve should
be a ball valve because it can be closed quickly.
3. Depending on the tool which you will be
using with this compressor, you may need to
incorporate additional components, such as an
in-line oiler, a filter, or a dryer (all sold separately),
as shown on Figure B on page 8 and
Figure C on page 9. Consult your air
tool’s manual for needed accessories.

MAINTENANcE

OpERATION

SETUp

f. Unplug the Power Cord and
remove the male coupler.

2. Connect a regulator valve, an inline shut off valve
and a 1/4″ NPT air hose to the Quick Coupler
(all sold separately). The air hose must be long
enough to reach the work area with enough extra
length to allow free movement while working.

SAFETy

Setup

Item 69666 69669

For technical questions, please call 1-888-866-5797.

Page 7

For technical questions, please call 1-888-866-5797.

Description

Non-lubricated
Tools

A

Air Hose
Filter
Regulator
Lubricator (optional)
Coupler and Plug
Leader Hose (optional)
Air Cleaner / Dryer (optional)
Air Adjusting Valve (optional)

MAINTENANcE

A
B
C
D
E
F
G
H

OpERATION
Lubricated
Tools

B

B

C

C

A

A

E

E

F

H

Connects air to tool
Prevents dirt and condensation from damaging tool or workpiece
Adjusts air pressure to tool
For air tool lubrication
Provides quick connection and release
Increases coupler life
Prevents water vapor from damaging workpiece
For fine tuning airflow at tool

G

D

Function

SETUp

Figure B: portable Air Supply Setup

SAFETy

Page 8

Item 69666 69669

Item 69666 69669

For technical questions, please call 1-888-866-5797.

Page 9

A
B
C
D
E
F
G
H
I
J
K
L
M
N
O

F
Description

F

E

I

I

J

OpERATION

N

K

J

H

Function

H

L

L

M

O

SETUp

SAFETy

For noise and vibration reduction
Secures air compressor in place
Isolates sections of system for maintenance
For vibration reduction
Distributes air to branch lines
To drain moisture from system
Brings air to point of use
Connects air to tool
Prevents dirt and condensation from damaging tool or workpiece
Adjusts air pressure to tool
For air tool lubrication
Provides quick connection and release
Increases coupler life
Prevents water vapor from damaging workpiece
For fine tuning airflow at tool

Non-lubricated
Tools

C

C

Vibration Pads
Anchor Bolts
Ball Valve
Isolation Hose
Main Air Line - 3/4″ minimum recommended
Ball Valve
Branch Air Line -1/2″ minimum recommended
Air Hose
Filter
Regulator
Lubricator (optional)
Coupler and Plug
Leader Hose (optional)
Air Cleaner / Dryer (optional)
Air Adjusting Valve (optional)

B
A

MAINTENANcE

B
A

C D

G

Lubricated
Tools

Slope

Figure c: Stationary Air Supply Setup

F

Operating Instructions
Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.

SAFETy

compressor Area Set Up
1. Designate a work area that is clean and well-lit.
The work area must not allow access by
children or pets to prevent injury.
2. Locate the Compressor on a flat level surface to
ensure proper pump lubrication and to prevent
damage to the unit. Keep at least 12″ of space
around the unit to allow air circulation.

3. Route the power cord from the compressor
to the grounded wall outlet, along a safe path
without creating a tripping hazard or exposing
the power cord to possible damage.

General Operation
SETUp

1. Close the Drain Valve.
2. Close the in-line Shutoff Valve between
the compressor and the air hose.
3. Plug the Air Compressor Power Cord into
a grounded 120 VAC electrical outlet.
4. Turn the Power Switch ON.
5. Allow the Air Compressor to build
up pressure until it cycles off.

OpERATION

Note: At the beginning of the day’s first use
of the Air Compressor, check for air leaks by
applying soapy water to connections while the
Air Compressor is pumping and after pressure cutout. Look for air bubbles. If air bubbles are present
at connections, tighten connections. Do not use the
Air Compressor unless all connections are air tight,
the extra air leaking out will cause the compressor to
operate too often, increasing wear on the compressor.

MAINTENANcE

Note: As long as the Power Switch is ON, the operation
of the Air Compressor is automatic, controlled by an
internal pressure switch. The Compressor will turn on
automatically when the air pressure drops to 125 PSI,
and will turn off automatically when the
air pressure reaches 150 PSI.
WARNING! TO pREVENT SERIOUS
INJURy AND DEATH FROM
EXpLOSION:
Do not adjust the internal
pressure switch. Any change to the automatic
pressure levels may cause excess pressure to
accumulate, causing a hazardous situation.

6. Adjust the Regulator Knob so that the air output is
enough to properly power the tool, but the output
will not exceed the tool’s maximum air pressure
at any time. Turn the knob clockwise to increase
the pressure and counter-clockwise to decrease
pressure. Adjust the pressure gradually, while
checking the air output gauge to set the pressure.
7. Make sure the air tool’s throttle or switch is in the
off position. Connect the air tool to the air hose.
8. Open the in-line Shutoff Valve.
9. Use the air tool as needed.
10. After the job is complete, turn the Power Switch OFF.
11. Unplug the Air Compressor.
12. Close the in-line Shutoff Valve.
13. Bleed air from the tool then disconnect the tool.
14. Open the Drain Valve lever, at the bottom of the Tank
to release any built-up moisture and the internal
tank pressure. Close the valve after moisture has
drained out. Do not remove the Drain Valve.
15. Clean, then store the Air Compressor indoors.

Emergency Depressurization
If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air pressure.

Page 10

For technical questions, please call 1-888-866-5797.

Item 69666 69669

Automatic Shut off System
2. Possible causes of repeated automatic
shut off of the compressor are:

a. Shut off all tools.

a. Using an extension cord that
is too long or narrow;

b. Wait until the Compressor cools down
(about 10 minutes);
c. If the unit does not start up again on its own,
move the Power Switch to OFF position,
then back to ON;

b. An air leak or open hose causing the compressor
to cycle too often and build up heat.
3. Correct any issues before further use to
avoid damage to the compressor.

SAFETy

1. If the Compressor automatically shuts off
before reaching its normal cutoff pressure:

d. Resume operation.

Maintenance and Servicing

SETUp

procedures not specifically explained in this manual must
be performed only by a qualified technician.

TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION:
Turn the power Switch “OFF” and unplug the compressor from its electrical outlet
before performing any inspection, maintenance, or cleaning procedures.
TO pREVENT SERIOUS INJURy FROM cOMpRESSOR FAILURE:
Do not use damaged equipment. If abnormal noise or vibration occurs,
have the problem corrected before further use.

1. BEFORE EAcH USE, inspect the general
condition of the air compressor. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may
affect its safe operation.

2. AFTER USE, wipe external surfaces
of the compressor with a damp cloth.
Check for air leaks by applying soapy
water to joints while the Air Compressor is
pressurized and looking for air bubbles.
3.

WARNING! If the supply cord of this
compressor is damaged, it must be replaced
only by a qualified service technician.

OpERATION

cleaning, Maintenance, and Lubrication

Maintenance Schedule
Following are general guidelines for maintenance checks of the Air Compressor.

Daily:

MAINTENANcE

Note: The environment in which the compressor is used, and the frequency of use can affect how often
you will need to check the Air Compressor components and perform maintenance procedures.
Weekly:

a. Make sure all nuts and bolts are tight.
b. Drain moisture from air tank.
c. Check for abnormal noise or vibration.
d. Check for air leaks.

Inspect Air Filter.
Monthly:
Inspect Safety Valve.

e. Wipe off any oil or dirt from the compressor.

Item 69666 69669

For technical questions, please call 1-888-866-5797.

Page 11

Draining Moisture from the Tank
The Drain Valve is located under the Tank. It must be used daily to release all trapped air and
moisture from the Tank. This will eliminate condensation which can cause tank corrosion.
1. Turn the Power switch of the compressor off.

SAFETy

2. Place a collection pan under the Drain Valve.

3. Turn Drain Valve lever downward
to release air inside.
4. When all the pressure and moisture is released,
close the Drain Valve.

Air Filter Maintenance
Check the Air Filter weekly to see if it needs replacement.
If working in dirty environments, you may need to replace the filter more often.
1. Remove the Cover.

3. Replace with a new Air Filter.

2. Remove the Air Filter.

4. Replace the Cover.

Troubleshooting
SETUp

problem
Compressor does
not start or restart

possible causes

Likely Solutions

1. Tank(s) already pressurized.

1. No problem. Compressor will start when needed.

2. Power cord not plugged in properly.

2. Check that cord is plugged in securely.

3. Incorrect power supply.

3. Check that circuit matches compressor requirements.

4. No power at outlet.

4. Reset circuit breaker, or have outlet
serviced by a qualified technician.

5. Thermal overload switch tripped.

5. Turn off Compressor and wait for it to cool down.
Resume operation.

6. Building power supply circuit tripped or
blown fuse.

6. Reset circuit or replace fuse. Check for low voltage
conditions. It may be necessary to disconnect
other electrical appliances from the circuit or
move the compressor to its own circuit.

OpERATION

7. Cord wire size is too small or cord is too 7. Use larger diameter or shorter extension cord or
long to properly power compressor.
eliminate extension cord. See Recommended Wire
Gauge for Extension Cords in Safety section.
Compressor builds
pressure too slowly

Compressor not
building enough
air pressure

MAINTENANcE

8. Compressor needs service.

8. Have unit inspected by a qualified technician.

1. Incorrect power supply.

1. Check that circuit matches compressor requirements.

2. Working environment too cold.

2. Move compressor to a warmer location.

3. Safety valve leaking.

3. Listen for air leaking from valve.
If leaking, replace with identical valve with same rating.
DO NOT SEAL OR TAMpER WITH SAFETy VALVE.

4. Loose fittings.

4. Reduce air pressure, then check all fittings with
a soap solution for air leaks and tighten as needed.
Do not overtighten.

1. Air filters need cleaning/replacing.

1. Check inlet and outlet filters.
Clean and/or replace as needed.

2. Check Valve needs service.

2. Have technician clean or replace, as needed.

3. Compressor not large enough for job.

3. Check if accessory CFM is met by Compressor.
If Compressor cannot supply enough air flow (CFM),
you need a larger Compressor.

4. Loose fittings.

4. Reduce air pressure, then check all fittings with
a soap solution for air leaks and tighten as needed.
Do not overtighten.

5. Hose or hose connections too narrow.

5. Replace with wider hose and/or hose connections.

6. High altitude reducing air output.

6. Higher altitudes require compressors
with greater output.

Follow all safety precautions whenever diagnosing or servicing the compressor.
Disconnect power supply before service.

Page 12

For technical questions, please call 1-888-866-5797.

Item 69666 69669

Troubleshooting (cont.)
Likely Solutions

1. Air filters need cleaning/replacing.

1. Check inlet and outlet filters.
Clean and/or replace as needed.

2. Unusually dusty environment.

2. Clean and/or replace filters more often or
move unit to cleaner environment.

3. Extension cord used.

3. Eliminate extension cord.

4. Unit not on level surface.

4. Reposition unit on a level surface.

1. Loose fittings.

1. Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.

2. Compressor not large enough for job.

2. Check if accessory CFM is met by Compressor.
If Compressor doesn’t reach accessory
CFM, you need a larger Compressor.

1. Loose or damaged belt guard.

1. Replace belt guard.

2. Loose fittings.

2. Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.

3. Unit not on level surface.

3. Reposition unit on a level surface.

Moisture in
discharge air

Too much moisture in air.

Install inline air filter/dryer, and/or relocate
to less humid environment.

Safety Valve “pops”

Safety valve needs service.

Pull on test ring of safety valve. If it still pops, replace.

Air leaks from
pump or fittings

Loose fittings.

Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.

Air leaks from tank

Defective or rusted tank.

Have tank replaced by a qualified technician.
Drain moisture from tank daily to prevent future corrosion.

Compressor
starts and stops
excessively

Excessive noise

SAFETy

Overheating

possible causes

SETUp

problem

pLEASE READ THE FOLLOWING cAREFULLy

MAINTENANcE

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

OpERATION

Follow all safety precautions whenever diagnosing or servicing the compressor.
Disconnect power supply before service.

Item 69666 69669

For technical questions, please call 1-888-866-5797.

Page 13

parts List and Diagram

parts List
SAFETy

part

SETUp
OpERATION
MAINTENANcE

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Description
Bolt M6x35
Spring Washer M6
Cylinder Head
Exhaust Elbow
Valve Plate
Inlet Valve Reed
Outlet Valve Reed
Limiter
Inlet Valve Reed Cover
Bolt M4x8
Spring Washer M4
Valve Plate Upper O-Ring
Valve Plate Lower O-Ring
Cylinder
Bolt M6x16
Connecting Rod Cover
Piston Ring
Connecting Rod
Nut M5
Spring Washer M5
Screw M5x25
Bearing 6203
Crank
Bolt M6x40
Fan
Bolt M6x16
Washer M6
Inner Teeth Washer M8
Nut M8
Bolt M5x195
Washer M5
Spring Washer M5
Nut M5
Run Capacitor
Bolt M3x6
Spring Washer M3
Washer M3
Start Capacitor
Crankcase
Motor Cover
Rotor
Stator
Washer 203
Rear Seat
Centrifugal Switch
Capacitor Bracket
Bolt M5x12
Bolt M4x6

Qty

part

4
5
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
2
2
4
8
8
4
1
4
4
4
1
1
1
1
1
1
1
1
1
4
1

49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95

Description

Qty

Washer Ø4
Bolt M5x6
Ground Symbol
Overload Protector
Strain Relief
Grommet
Bolt M8x25
Washer M8
Spring Washer M8
Nut M8
Front Shroud
Rear Shroud
Shroud Cover
Bolt M5x15
Screw ST4.0x25
Screw ST4.2x30
Screw ST3.8x12
Pressure Switch
Strain Relief
Connector 1/4″ NPT x 30
Pressure Gauge (270 PSI 1/4″ NPT)
Pressure Gauge (270 PSI 1/8″ NPT)
Regulator
Quick Coupler
Safety Valve
Connector 1/4″ NPT x 48
Check Valve
Brass Washer
Pressure Tube
Compression Nut Ø3/8″
Relief Tube
Relief Nut
Power Cord
Cable Connector U
Cable Connector O
Axle
Wheel 8"
Rubber Foot
Bolt M8x20
Drain Valve (Not shown)
Tank
Handle
Bolt M6x20
Rivet Nut M6
Washer M6
Air Filter
Handle Grip

1
1
1
1
1
2
4
12
6
8
1
1
1
4
1
2
4
1
2
1
1
1
1
1
1
1
1
2
1
2
1
1
1
2
1
2
2
2
2
1
1
1
4
4
4
1
1

Record product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and are not available individually
as replacement parts. Parts may not be interchangeable. Specify number when ordering.
Page 14

For technical questions, please call 1-888-866-5797.

Item 69666 69669

Assembly Diagram
1
94

2

SAFETy

3
12

35
36
37

7
9
10

13

15

6

42

23

22

5149
52

54
50

70
69

66

61

60
63

48

53

41
55
56
57
58

2
24

20
21

26

44

40

22

27

45

43

39
32

30

32

33

25 19

31

47

22

31

17
18

47
32

38

14

16

34 28 29 46

SETUp

5

4

59

65
75

74

67

73

68

71

72

90

64

OpERATION

10
11

8

95

62
93
76
78

92

91

MAINTENANcE

77

89
79
80
83
81

82

58
56
57 58

84
Item 69666 69669

85

86
56
87

For technical questions, please call 1-888-866-5797.

Page 15

Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards,
and warrants to the original purchaser that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries
to persons or property, or for incidental, contingent, special or consequential damages arising from the use of
our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges
prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may
elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will
return repaired products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

3491 Mission Oaks Blvd. • pO Box 6009 • camarillo, cA 93011 • 1-888-866-5797



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 48
Producer                        : Mac OS X 10.11.6 Quartz PDFContext
Create Date                     : 2017:06:13 23:04:48Z
Modify Date                     : 2017:06:13 23:04:48Z
EXIF Metadata provided by EXIF.tools

Navigation menu