DTV735 Digital Television Processor (Fox Version) User's Manual 800021 01B

User Manual: 800021-01B

Open the PDF directly: View PDF PDF.
Page Count: 40

DownloadDTV735 Digital Television Processor (Fox Version) User's Manual 800021-01B
Open PDF In BrowserView PDF
DTV735
Digital Television Processor
Fox Version

User's Manual

DTV 735 User’s Manual

Data, drawings, and other material contained herein are proprietary to Wegener
Communications, Inc., and may not be reproduced or duplicated in any form
without the prior written permission of Wegener Communications, Inc.
The information contained herein is subject to change without notice. Revisions may be issued to advise of such changes and/or additions.
Correspondence regarding this publication (800021-01B) should be forwarded
to:
Wegener Communications, Inc.
Technology Park/Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Phone: 770-814-4000
Fax:

770-497-0411

DTV735 and COMPEL are trademarks of WEGENER Communications, Inc.
All Rights Reserved.
All other trademarks are the property of their respective owners.

The Wegener DTV735 is approved under FCC Part 15B Class A, UL1950, and
CSA.

800021-01 Rev. B

2

wegener.com

DTV 735 User’s Manual

Table of Contents
Chapter 1 General Information
1.1 Manual Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 DTV735 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 DTV735 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Safety Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 Glossary of Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . 9

Chapter 2 Installation
2.1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Location and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 DTV735 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Terminal I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Chapter 3 Operation
3.1 Operation Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2 Ethernet/Web Browser Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Directly connected PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LAN Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Using the Web Browser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Control and Status Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Configuration Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Stream Information Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Q&A/Help Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.3 DTV735 Controls and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Liquid-crystal Display(LCD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Push buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Front-panel LED Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Rear-panel indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.4 Front-panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Home screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Alarms/Warnings screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Clear Errored Seconds screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Program Setup screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Program Status screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Output Rate Selection screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Pass PID 0x0ffe Selection screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
IP Setup screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Reset Unit screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
wegener.com

3

800021-01 Rev. B

DTV 735 User’s Manual

3.5

3.6

3.7
3.8

Unit Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Software Code Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Initialization Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Initialization Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Transport Stream Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Input to Output Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PSIP Structure and Program Selection . . . . . . . . . . . . . . . . . . . . . . . 33
IRT Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Alarm System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Alarm Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Software Downloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Chapter 4 Maintenance and Troubleshooting
4.1 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.2 General Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
No functions at all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Normal Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
ALARM: ASI Input Unlocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
ALARM: Unit Over-subscribed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
ALARM: PAT or PMT Missing. . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.4 Trouble with Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Chapter 5 Customer Service
5.1 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.2 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

800021-01 Rev. B

4

wegener.com

Chapter 1 General Information
1.1 Manual Overview
This manual provides instructions and reference information for the proper
installation and operation of the Wegener Model DTV735 Digital Television
Processor, referred to throughout the manual as the DTV735.
NOTE: User interface details in this manual are based on application software
version 102.
The manual is divided into the following chapters:
1 General Information - a description of your DTV735, its functions and
specifications, and a glossary of terms
2 Installation - procedures and information for the correct and safe installation of your DTV735.
3 Operation - instructions on starting and operating your DTV735
4 Maintenance and Troubleshooting - information on maintaining your
DTV735 and resolving possible operating difficulties
5 Customer Service - Our warranty and information on obtaining help
Please E-mail any suggestions or comments concerning this manual to
manuals@wegener.com. If you prefer to post them through the mail, please
send your comments to the address below. If you have substantial or complex
changes to recommend, our preference is that you copy the page(s) in question,
mark your changes on that copy, and fax or mail us the copy. We always
appreciate constructive criticism.
Our Address:
Attn: Manuals
Wegener Communications, Inc.
Technology Park / Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Our Fax Number:(770) 497-0411

wegener.com

5

800021-01 Rev. B

DTV 735 User’s Manual

1.2 DTV735 Overview
The DTV735 Digital Television Processor (see Figure 1.1) receives an input
ASI MPEG Transport Stream and provides an output DHEI stream for connection to cable system transmission equipment. Programs may be remapped or
selected for removal from the output stream. The Transport Stream that is output on the DHEI connector is also available on the two ASI output BNC connectors.
Physical
Description

The DTV735 is housed in a standard, rack-mountable chassis. Its front panel
provides a user interface through an LCD, eight LEDs, and six push buttons
(see section 3.3 DTV735 Controls and Indicators on page 23). The rear panel
holds the ports that allow connection to power, incoming signal, and peripheral
devices.

Figure 1.1 DTV735 Digital Television Processor
Features

Your DTV735 has the following features:
• Two ASI MPEG Transport Stream inputs – ASI-1 is active, ASI-2 may
be used for future expansion (BNC connectors)
• Two duplicate ASI MPEG Transport Stream outputs (BNC connectors),
• DHEI Output Module,
• Time re-stamping of PCR, PTS, and DTS information,
• User selection of input programs to be included in the output stream,
• User selection of output program numbers and audio mode,
• One Ethernet TCP/IP control interface (RJ-45 connector), and
• One asynchronous data input/output (DB-9 connector).

800021-01 Rev. B

6

wegener.com

DTV 735 User’s Manual

1.3 DTV735 Specifications
Table 1: Technical Specifications
Characteristic

Specification

ENVIROMENTAL
Use

Indoor

Altitude

Up to 2000 meters

Temperature Range

+10° C to +40° C Operating
-20° C to +70° C Storage

Cooling

Internal fan

Relative Humidity (max.)

80% for temperatures up to 31° C decreasing linearly to
50% relative humidity at 40° C.

INPUT AC POWER
Voltage

90 to 132 Vac and 175 to 264 Vac

Frequency

50/60 Hz ± 2%

Power Consumption

43 Watt

MECHANICAL
Height

1 std. RU (1.75 inches nominal) (44.5 mm)

Width

EIA std. 19-inch mounting (482.6 mm)

Depth

13.5 inches (342.9 mm)

Weight

10.5 lb (4.81 kg)

Expansion Module Slots

3 - each 2.5"W x 1.375"H x 7"D on rear panel

SERIAL PORTS
Standard

RS-232

Handshaking

None

Service

Software download

Baud Rates

115.2 kbps

Formatting

8 data-bits, 1 start, 1 stop-bit, no parity

wegener.com

7

800021-01 Rev. B

DTV 735 User’s Manual

Table 1: Technical Specifications
Characteristic

Specification

ETHERNET PORT
Physical Layer

10BaseT/100BaseT (twisted pair) on RJ-45 jack

Media Access and Link Layer

Per IEEE 802.3 (Ethernet)

ALARM RELAYS
Alarm Function

Contact closure for main power off, loss of input signal

Type

Form C, Normally Open and Normally Closed

Rating

30Vdc open circuit, 500 mA max current closed

EXPANSION MODULE SLOT

Allowable expansion modules:
· DHEI transport stream output
· 8VSB tuner module

1.4 Safety Summary
The DTV735 is designed for safe use with few special precautions required of
the user. The following items are basic precautions to use when installing and
working with your DTV735:
Do not open the DTV735’s chassis cover.

800021-01 Rev. B

8

wegener.com

DTV 735 User’s Manual

1.5 Glossary of Terms and Abbreviations
Table 2: Glossary of Terms
Term

Definition

AC

Alternating current

Alarm

A condition or notification of a condition that prevents your DTV735 from performing
properly

Application Software

The main host software which sets up the unit hardware, runs the process of acquiring
Transport Stream sources, sets up and monitors the multiplexing processes, monitors
unit operations, and provides interfaces with the network and local users.

ASI (or DVB-ASI)

An “asynchronous” bit-serial physical interface for Transport Streams. Transmitting
and receiving functions are designed such that the time relationships between all packets and their timing references are unchanged.

ATSC

Advanced Television Systems Committee - sets standards for standard definition and
high definition television in the U.S. Sometimes used to mean the HDTV standards.

Boot loader

Software residing in non-writable zone of flash which executes at unit reset.

Carrier

An RF signal containing coded audio, video, and/or other data

DVB-ASI

see ASI

EIA

Electronic Industries Association

Ethernet

The widely-used LAN technology specified by IEEE standard 802.3

Flash memory

A memory dedicated to storing the unit’s software and an image of some hardware programming code.

IEEE

Institute of Electrical and Electronics Engineers

LAN

Local area network. Your DTV735 may be connected to an Ethernet LAN.

LCD

Liquid crystal display. The front-panel text screen on your DTV735 is a liquid crystal
display.

LED

Light-emitting diode. The front-panel indicator lights on your DTV735 are LEDs.

Mbps, kbps

Megabits per second or kilobits per second - units of data transport rate.

MPEG

Moving Picture Experts Group - refers to the method of video compression established
by this group.

NVRAM

Non-volatile memory. A memory dedicated to storing the unit’s setup parameters. This
memory retains its contents through power outages.

PAT

Program Allocation Table. Master table which identifies all the Programs in the Transport Stream. It associates Program numbers to the PIDs bearing the associated Program’s PMT.

wegener.com

9

800021-01 Rev. B

DTV 735 User’s Manual

Table 2: Glossary of Terms
Term

Definition

PCR

Program Clock Reference. Time-base signal used to synchronize transport stream data.

PID

Packet Identifier. The unique Transport Stream packet identifier assigned to each constituent data stream within the Transport Stream. Also, in this document, “PID” is used
to designate the stream itself.

PMT

Program Map Table. Table for a given Program identifying all the PIDs for its PCR,
video, audio, and user data streams.

Program

In the MPEG hierarchy, a grouping of related audio, video, or generic data PIDs sharing
a common PCR time base and (usually) sharing a common schedule. See PMT.

PSI Tables

Program-Specific Information Tables. A group of information-bearing tables, each
borne by well-known PIDs, regularly transmitted in the Transport Stream. See also
“PAT” and “PMT”. Also, ISO 13818-1 gives a thorough description of these and other
Tables.

PSIP

Program and System Information Protocol - a method for transporting digital television
system information and electronic program guide data.

RAM

Random access memory. A general term for all memory volatile memory types out of
which application software executes and into which its variables, state information, and
messages are stored. RAM is also used to designate the volatile storage used by the
Transport Demux and decompression devices.

RF

Radio frequency

TMRA

Maximum Recommended Ambient Temperature, the highest operating temperature for
which the unit is rated

Transport Stream
(or MPEG Transport Stream)

A multiplex of several data streams, each of which is borne in Transport packets, 188byte blocks containing a sync word, header information (including a PID), and payload
data. This multiplex includes PSI data tables, Programs, and padding in the form of null
packets.

800021-01 Rev. B

10

wegener.com

Chapter 2 Installation
This chapter provides instructions on unpacking, mounting, and connecting
your DTV735 as well as connector information including detailed pinouts.

2.1 Unpacking and Inspection
Carefully unpack the unit and its ac power cord and inspect for obvious signs
of physical damage that might have occurred during shipment. Any damage
claims must be reported to the carrier immediately. Be sure to check the package contents carefully for important documents and materials.
NOTE: Please save the packing materials and original shipping containers in
case you must later return the unit for repair. Packing these units in other
containers in such a way that they are damaged will void your warranty.

2.2 Location and Mounting
The DTV735 should be located indoors and may be mounted in a standard,
19-inch equipment rack within one standard RU.
WARNING
This is a Class A product. In a domestic environment this product may cause
radio interference for which the user may need to take mitigating action.

wegener.com

11

800021-01 Rev. B

DTV 735 User’s Manual

DANGER
To avoid damage to this and other equipment, or personal injury, the following
items should be strictly observed.
Elevated Operating Ambient
When equipment is installed in a closed or multi-unit rack assembly, the
operating ambient of the rack environment may be greater than the room
ambient. Therefore, consideration should be given to the ambient air
temperature within the rack, and not just inside the room, when deciding if the
maximum recommended ambient operating temperature (TMRA) is being met
or exceeded.
Reduced Air Flow
Equipment should be installed such that airflow required for safe operation of
the equipment is not compromised.
Mechanical Loading
Mounting of the equipment in a rack should be such that a hazardous
condition is not produced by uneven loading. This unit is not very heavy, but
total rack loading must be considered. Also, do not rest any unsupported
equipment on your DTV735.
Circuit Overloading
Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of circuits could have on
overcurrent protection and supply wiring. Ensure that the total rack or breaker
power consumption does not exceed the limits of the ac branch circuit.
Appropriate consideration of equipment ratings should be used when
addressing this concern.
Reliable Earthing
Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections
to the branch circuit (use of power strips, chassis ground lugs, etc.).

800021-01 Rev. B

12

wegener.com

DTV 735 User’s Manual

Rack
Mounting

Your DTV735 is sized to fit in an EIA-standard, 19-inch-wide equipment rack.
a) First install angle brackets or cross-supports capable of supporting both
the unit and its connecting cables. Screw or bolt the supports securely
to the equipment rack.
b) Place the DTV735 on its supports and use four anchor screws or bolts
and nuts to secure the unit’s front brackets to the rack.
c) Connect the chassis grounding screw to an earth ground before
connecting the power cord to the unit.
WARNING
The front brackets must be secured to the rack. If front brackets are left
unsecured, the unit may shift forward and fall from the rack during installation
or operation. Failure to secure the front brackets may result in personal injury
and/or damage to the equipment.

WARNING
Locate the DTV735 and its cables to avoid impacts, spills, and pulling cables
and to ensure sufficient air flow. Failure to locate the DTV735 in a proper
environment may result in damage to the equipment.

wegener.com

13

800021-01 Rev. B

DTV 735 User’s Manual

2.3 DTV735 Connections
Figure 2.1 DTV735 System Setup below shows placement of the DTV735 in a
typical cable headend. Figure 2.2 DTV735 Rear Panel illustrates details of the
DTV735’s rear panel.

Figure 2.1 DTV735 System Setup

Figure 2.2 DTV735 Rear Panel
Before applying power, make the following connections to your DTV735
(refer to Table 3 for connector details):
a) Connect the chassis grounding screw to an earth ground before
connecting the power cord to the unit.
b) Connect the ASI Output signal from your Unity 4600 receiver to the
DTV735’s ASI IN 1 port.
c) Connect the DHEI output connector to the cable headend DHEI
equipment using a 15-pin to 26-pin DHEI cable. Be sure to use the
correct cable depending upon whether you are connecting to the DHEI
Expansion Input or the DHEI Expansion Output connector.

800021-01 Rev. B

14

wegener.com

DTV 735 User’s Manual

d) Connect other transmission or monitoring equipment to the ASI OUT 1
and ASI OUT 2 ports as desired.
e) Connect your LAN line to the DTV735’s Ethernet port.
f) If desired, connect the Relays port to your equipment to provide contact
closures during alarms.
g) Finally, connect the supplied ac power cord to the DTV735’s IEC
receptacle and to a 90-to-132 Vac source.
Table 3: DTV735 Connector Details
Designation

Connector Type

Pin
Number

Signal Name

115/230 Vac Power

Male IEC receptacle

AC LINE IN

ASI In 1

female BNC

ASI IN 1

ASI In 2

female BNC

ASI IN 2

ASI Out 1

female BNC

ASI OUT 1

ASI Out 2

female BNC

ASI OUT 2

DHEI Out

D subminiature 15-pin

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RESERVED
RESERVED
RESERVED
RESERVED
SIGND
SENSEOL
PSYNCO+
PDATAO+
PCLKO+
REFCLKO+
SENSEOR
PSYNCOPDATAOPCLKOREFCLKO-

Ethernet LAN

female RJ-45

1
2
3
4
5
6
7
8

EN OUT +
EN OUT EN IN +
NC
NC
EN IN NC
NC

wegener.com

15

800021-01 Rev. B

DTV 735 User’s Manual

Table 3: DTV735 Connector Details
Designation

Connector Type

Pin
Number

Signal Name

Serial Async I/O

DB-9

1
2
3
4
5
6
7
8
9

DCD (+5V, 4.7 kΩ)
RxD (output)
TxD (input)
NC
GND
DSR (+5V, 4.7 kΩ)
NC
CTS (+5V, 4.7 kΩ)
RI (+5V, 33 Ω)

Alarm Relay

male DB-9

1
2
3
4
5
6
7
8
9

Not used
Not used
Not used
ALARM COM
GND
Not used
Open on ALARM
Not used
Close on ALARM

Ethernet

An Ethernet 10BaseT/100BaseT port is included and is the primary user interface using an HTML browser-based interface. The unit has an URL which is
assigned via the front panel. The “home” page is then accessed by users via the
Ethernet port. From this page, the desired channel selections may be performed
and status monitored.

Terminal I/O

The Terminal serial port is configured to 115.2k, N, 8, 1. The Terminal device
is used for command and control of the DTV735. This I/O is a basic, VT100like emulation. User input text strings terminated in carriage-returns prompt all
I/O. The terminal should be set to local echo ON because the DTV735 only
echoes a carriage-return/linefeed and then a ‘>’ prompt after entry of a command-line terminated in carriage-return.

800021-01 Rev. B

16

wegener.com

Chapter 3 Operation
3.1 Operation Overview
This chapter contains detailed operating instructions for your DTV735. The
following sections address:
• Ethernet/Web Browser Control
• DTV735 Controls and Indicators
• Front-panel Operation
• Initialization
• Transport Stream Processing
• Alarm System
• Software Downloads
Local user control is from a LAN via RJ-45 Ethernet or the front-panel LCD/
keypad. All settings may be presumed to be retained through power cycling
unless otherwise specified. This means that they are still in effect through
resets, whether by power outage, commanded reset, or failure-recovery resets.

3.2 Ethernet/Web Browser Control
The DTV735’s primary user interface is from a web browser using the rearpanel Ethernet LAN connection. An HTML script interface allows a user to
control and monitor the unit using a standard web browser. Each unit contains
a user-defined quad URL address, subnet mask, and gateway address (See
Table 4: DTV735 IP Setup).
There are two basic methods of using the Ethernet connection – with a directly
connected PC or with a PC connected through a LAN.
Directly
connected PC

For control from a local PC, attach the DTV735’s Ethernet port to the Ethernet
network connector on the PC using a crossover RJ-45 cable (8 pins).
Before using this Ethernet connection, the appropriate IP address, netmask,
and gateway must be selected via the front-panel interface.

wegener.com

17

800021-01 Rev. B

DTV 735 User’s Manual

Perform the DTV735 IP Setup as shown in Table 4 and the PC IP Setup as
shown in Table 5:
Table 4: DTV735 IP Setup
Parameter

Setting

IP Address

172.016.100.020

Netmask

255.255.000.000

Gateway

000.000.000.000

Table 5: PC IP Setup

LAN
Connection

Parameter

Setting

IP Address

172.016.100.001

Subnet Mask

255.255.000.000

For LAN connection, attach the DTV735’s Ethernet port to the LAN using a
normal, straight-through, RJ-45 cable (8 pins). Set the DTV735 IP Address,
Netmask, and Gateway as directed by your network administrator. Use any PC
on the LAN to connect to the DTV735 using the web browser instructions
below.
NOTE: Each unit on the network must have a unique address.

Using the
Web Browser

To begin monitor and control functions from a PC or LAN connection:
a) Open the current internet browser of your choice from the local PC or
computer on the LAN attached to your DTV735.
b) Set the browser's address field to http://nnn.nnn.nnn.nnn where
nnn.nnn.nnn.nnn is the IP address of the unit to be controlled (set from
the DTV735’s front-panel, IP Address screen).
NOTE: For IP addresses which include subfields with leading zeros, you must
omit those zeros when entering the address in your browser. For example, IP
address 128.092.050.004 must be entered as 128.92.50.4.
The DTV735 Control and Status screen will appear. You may select either the
Stream Information, Configuration, or Q&A/Help pages at any time by clicking on their respective tabs at the top of the screen.
Normally you will first select the Control & Status screen to select the output
data rate and then select the Configuration screen. Use the Configuration

800021-01 Rev. B

18

wegener.com

DTV 735 User’s Manual

screen to select the included programs for output, assign new program numbers
if desired, and select the audio to be included in each program’s output. Finally,
select the Stream Info screen to verify the input and output data processed.
Control and
Status Page

The Control side of this screen gives the serial number of the DTV735 unit and
the version number of the application software installed in the unit. The ASI
Output box allows the user to set the output data rate to either 26.97 Mbps or
38.81 Mbps. The IRT Mode box allows the user to enable or disable functions
needed for use in systems with the Motorola IRT product. This is normally set
to OFF. (Refer to IRT Mode on page 34 for more details.)

The Status side provides the unit input and output signal status. The ASI Input
part of Status indicates the presence or lack of an ASI input signal on ASI
Input 1. The Errored Secs indicates the number of seconds in which errors
occurred since the last time the error counter was cleared. ASI/DHEI Output
lists the output stream’s data transport rate as well as the output lock status.
(The QAM modulator associated with the data rate is shown after the data rate,
64 QAM for 26.97 Mbps or 256 QAM for 38.81 Mbps.) Utilization indicates
the percentage of the output Transport Stream’s data rate that is occupied with
actual data (not null packets). This indicator may be used to determine whether
additional programs may be enabled for output.

wegener.com

19

800021-01 Rev. B

DTV 735 User’s Manual

Configuration
Page

The Configuration screen shown below allows the selection of programs to be
included in the output. In the example shown, programs 1 through 7 have been
selected by placing a check in the boxes next to the input program number.
Program reassignments have been selected by placing the new output numbers
in the corresponding Prog. Output boxes. For example, Input Program 1 is
mapped to Output Program 7, Input Program 2 to Output Program 17, etc. The
Audio selection boxes allow MPEG audio, AC-3 audio, or both to be selected
for output on each program. You should ensure that the selected audio format is
available on the input program. If you select MPEG only and the input has AC3 only, you will receive video but no audio for that program. If in doubt, select
both.

800021-01 Rev. B

20

wegener.com

DTV 735 User’s Manual

Stream
Information
Page

The Stream Info screen shown below allows additional control and monitoring
of the input and output streams. The ASI 1 Input side shows all the programs
present in the ASI input. The number in parentheses after the program number
is the PID number (in hexadecimal form) of that program’s PMT. All streams
included in the program are listed below the program number with their PID
locations indicated in parentheses (in hexadecimal form). For example, in the
screen below, Program 3 has its PMT located in PID 0x3a and its video is
located in PID 0x0130 with audio located in PIDs 0x0131 and 0x0132. Check
boxes allow you to select the program streams that you wish to include in the
output. Click the box to the left of a program to check that program and add it
to the output and then click the Update Selected Programs bar at the bottom of
the screen. Click the Uncheck All hyperlink if you wish to remove checks from
all input check boxes.
Program numbers may be changed by entering the desired values in the program number boxes before clicking on the Update Selected Programs box. Program numbers must be unique. If you attempt to assign the same program number to more than one program, an error message will appear and no change will
be made.
NOTE: Program numbers are unique. Do not attempt to assign two input
programs to the same output program number.

wegener.com

21

800021-01 Rev. B

DTV 735 User’s Manual

Q&A/Help
Page

A list of questions and answers about operating your DTV735 is available on
the Q&A/Help page. Click the Q&A/Help tab to display this page.

800021-01 Rev. B

22

wegener.com

DTV 735 User’s Manual

3.3 DTV735 Controls and Indicators
There are three major parts of your DTV735’s front-panel controls and indicators: the liquid-crystal display (LCD), the six push buttons, and the eight LED
indicators. Essentially all control available through the terminal is also available via the front panel (shown below in Figure 3.1).

Figure 3.1 DTV735 Front Panel
Liquidcrystal
Display(LCD)

The DTV735’s 2-line by 20-character LCD indicates unit status and prompts
for and reflects user input. Here, you will see your DTV735’s "home screen"
which shows the Transport Stream ID (TSID) and the output data rate. Information in the bottom row alternates between showing the number of errored
seconds since signal acquisition (or since error reset) and the occupied bandwidth of the output data stream. No matter which front panel screen is currently shown, holding in the ESC button returns the display to the home
screen. From this home screen, press the ENT button to display the unit’s serial
number and the version number of the application software. Using the adjacent
push buttons, you can navigate the DTV735’s various screens and edit input
fields (see section 3.4 Front-panel Operation on page 26).

TSID:XXXX RATE:YY.YY
Errored Sec:ZZZZ

TSID:XXXX RATE:YY.YY
Occupied BW: NN%

The default front panel screen is this "home screen". No matter where a user
may be in the screen hierarchy, if no front-panel key press is made for more
than five minutes, then the screen reverts to the “home screen”.

wegener.com

23

800021-01 Rev. B

DTV 735 User’s Manual

Push buttons

These six push buttons (shown below in Figure 3.2) are your means of commanding the DTV735 from the front panel. The four arrow buttons allow navigation through the menu screens and character selection when editing userinput fields. The Enter (ENT) button serves to select menu options (downward
navigation), to open user-input fields, or to commit user input to the DTV735.
The Escape (ESC) button allows exit from user-input fields without saving the
entry or selection. ESC also provides upward navigation through the menu
structure to the home screen. The arrow buttons also provide navigation
through user-input screens and switching between user-selectable options.

Figure 3.2 DTV735 Push Buttons
Front-panel
LED
Indicators

Figure 3.3 below shows the eight light-emitting diodes (LEDs) that provide
status information about your DTV735 and its processes. Table 6: LED Indicator Descriptions on page 25 provides the meaning of the color and state of
each LED.

Figure 3.3 DTV735 LED Indicators

800021-01 Rev. B

24

wegener.com

DTV 735 User’s Manual

Table 6: LED Indicator Descriptions
Indicator
Label and Color
OPTION MOD 1
GREEN
OPTION MOD 2
GREEN
ASI 1 LOCK
GREEN

ASI 2 LOCK
GREEN

WARNING

YELLOW
ASI OUT LOCK
GREEN
ALARM
RED
LAN ACTIVITY
GREEN

Indicator State

Indicator Meaning

Constant Option module 1 installed and operating
Off Option module 1 not installed or not operating
Constant Option module 2 installed and operating
Off Option module 2 not installed or not operating
Constant ASI 1 input has Transport Stream synchronization
present
Off ASI 1 input does not have Transport Stream
synchronization present
Constant ASI 2 input has Transport Stream synchronization
present
Off ASI 2 input does not have Transport Stream
synchronization present
Constant Warning condition(s) exists
(The Fox version of the DTV735 does not have any
Warning conditions.)
Off

No Warning condition exists

Constant ASI Output is active
Off ASI Output is inactive
Constant Alarm condition(s) exists
Off No Alarm condition exists
Flash

LAN activity present. Only lights when data is
transferred to the DTV735. This is not a continuous monitor of LAN communications.

Off No transfer of LAN data to the unit

wegener.com

25

800021-01 Rev. B

DTV 735 User’s Manual

Rear-panel
indicators

Three LED indicators on the rear panel give Ethernet and ASI Input status:
ACT – LED: Ethernet activity blinks OFF and ON for activity detected
LAN – LED: Ethernet rate indicator, OFF for 10baseT and ON for 100baseT
ASI Input – Red/Green LED: OFF for not selected, RED for no input signal,
GREEN for input signal detected

3.4 Front-panel Operation
The DTV735 may be set up and controlled from the front panel as follows:
NOTE: From any screen, pressing the ESC key twice will return you to the
Home Screen.
Home screen

The Home screen alternates between the following two modes every four seconds:
(A)
TSID:XXXX RATE:YY.YY
Errored Sec:ZZZZ
Where XXXX is the hexadecimal transport stream identifier, YY.YY is the
current output rate in Mbps, and ZZZZ is the number of errored seconds
since the last reset of the counter.
(B)
TSID:XXXX RATE:YY.YY
Occupied BW: NN%
Where NN is the percentage of the unit's output bandwidth currently occupied by selected programs.
Press the ENT key to view the second-level Serial Number and Application
Software Version Number screen.
Press the
key to go to Alarms/Warnings.

800021-01 Rev. B

26

wegener.com

DTV 735 User’s Manual

Second-level Screen
Serial Number and Application Software Version Number Screen
S/N: XXXXXX
VER: YYY
Where XXXXXX is the unit's six-digit serial number and YYY is the version
number of the unit's currently installed application software.
Press the ESC key to return to the Home Screen.
Alarms/
Warnings
screen

View Alarms/Warnings
Press the ENT key to view any active alarms or warnings on the secondlevel Alarms/Warnings Message screen.
Press the
key to go to Clear Errored Seconds (if counter is non-zero) or
Program Setup.
Press the ESC key to go to the Home Screen.
Second-level Screen
Alarms/Warnings Message Screen
No Alarms
Any active alarms or warnings are described here.
Press the
key to view the next alarm or warning (if more than one).
Press the ESC key to return to the Alarms/Warnings screen.

Clear
Errored
Seconds
screen

Clear Errored Secs
Press
This screen only appears if the errored seconds counter is non-zero. Otherwise the next screen, Program Setup is displayed.
Press the ENT to clear the errored seconds counter.
Press the
key to go to the Program Setup screen.
Press the
key to go to Alarms/Warnings.
Press the ESC key to go to the Home Screen.

wegener.com

27

800021-01 Rev. B

DTV 735 User’s Manual

Program
Setup screen
Program Setup...
Select? Press
Press the ENT key to bring up the second-level Program Input screen.
Press the
key to go to Program Status.
Press the
key to go to Clear Errored Seconds (if counter is non-zero).
Press the ESC key to go to the Home Screen.
Second-level screens
Program Input Screen
ProgIn XXXXX
ABCDEF
Where XXXXX is the program number and ABCDEF is the service descriptor
for that program.
Press the
key to go to the next program on the input stream.
Press ENT and use the or keys to select  or , adding or
removing this program to or from the output stream. Press ENT again to
confirm.
Press the
key to go to the Output Remap screen.
Press the ESC key to return to the Program Input screen.
Press the ESC key again to return to the main-level Program Setup screen.
Output Remap Screen
Output Remap:
XXXXX
Where XXXXX is the output program number.
Press the ENT key to edit the output program number.
Press the
key to go to the Audio Stream Selection screen.
Press the
key to go to the Program Input screen.
Press the ESC key to return to the Program Input screen.
Press the ESC key again to return to the main-level Program Setup screen.

800021-01 Rev. B

28

wegener.com

DTV 735 User’s Manual

Audio Stream Selection Screen
Audio Stream:
XXXX
Where XXXX is the currently selected audio stream.
Press ENT and use the or keys to select , , or . Press ENT again to confirm.
Press the
key to go to the Output Remap screen.
Press the ESC key to return to the Program Input screen.
Press the ESC key again to return to the main-level Program Setup screen.
Program
Status screen
Program Status...
Select? Press
Press the ENT key to view the second-level program status screens.
Press the
key to go to Output Rate Selection.
Press the
key to go to Program Setup.
Press the ESC key to go to the Home Screen.
Second-level screens
2nd-level Program Status Screen
ProgIn XXXXX AAAAAAA
ProgOutYYYY BBBBBBB
where XXXXX is the program number at input, AAAAAAA is the service
descriptor for the program, YYYY is the decimal program number at output,
and BBBBBBB is the available audio on the input for the program (AC-3,
MPEG, or MPG/AC3).
Press the
key to view the status of the next program (all programs present
may be viewed but only programs 1 through 16 may be selected for output).
Press the ESC key to return to the Program Status screen.

wegener.com

29

800021-01 Rev. B

DTV 735 User’s Manual

Output Rate
Selection
screen

Output Rate...
38.81 Mbps
Press the ENT key and then the or key to select 26.97 Mbps (64QAM)
or 38.81 Mbps (256QAM). Press the ENT key to confirm the selection.
Press the
key to go to IRT Mode Selection.
Press the
key to go to Program Status.
Press the ESC key to go to the Home Screen.

IRT Mode
Selection
screen

Select ON to enable the DTV 735’s IRT mode. See IRT Mode on page 34 for
more details.
IRT Mode
OFF
Press the ENT key and then the or key to select OFF or ON. Press the
ENT key to confirm the selection.
Press the
key to go to IP Setup.
Press the
key to go to Output Rate Selection.
Press the ESC key to go to the Home Screen.

IP Setup
screen
IP Setup...
Press the ENT key to go to IP Address Selection.
Press the
key to go to Reset Unit Screen.
Press the
key to go to IRT Mode Selection.
Press the ESC key to go to the Home Screen.

800021-01 Rev. B

30

wegener.com

DTV 735 User’s Manual

Second-level screens
IP Address Selection Screen
IP Address:
000.000.000.000
Press the ENT key and then press the arrow keys to change the IP address.
Press the ENT key to confirm the selection.
Press the
key to go to the Netmask Selection.
Press the ESC key to go to IP Setup.

Netmask Selection Screen
Netmask:
255.255.0.0
Press the ENT key and then press the arrow keys to change the Netmask.
Press the ENT key to confirm the selection.
Press the
key to go to Gateway Selection.
Press the
key to go to IP Address Select.
Press the ESC key to go to IP Setup.

Gateway Selection Screen
Gateway:
0.0.0.0
Press the ENT key and then press the arrow keys to change the Gateway.
Press the ENT key to confirm the selection.
Press the
key to go to Netmask Selection.
Press the ESC key to go to IP Setup.

wegener.com

31

800021-01 Rev. B

DTV 735 User’s Manual

Reset Unit
screen
Reset Unit...
Press the ENT key to go to the second level Reset Unit Entry screen.
Press the
key to go to the Home Screen.
Press the
key to go to IP Setup.
Press the ESC key to go to the Home Screen.
Second-level screens
Reset Unit Entry Screen
Reset Unit...
Press 
Press the ENT key to reset the unit and start the boot loader.
Press the ESC key to go to the Reset Unit Screen.
Unit
Shutdown

Simply remove power to the unit to shut down your DTV735. No special procedure is required.

3.5 Initialization
Software
Code
Structure

The DTV735 Processor contains the following unit software: A boot loader
and one version of operating application software. Before power-up, these
components are stored in non-volatile memory. The boot loader resides in a
portion of the memory that may only be written at the factory while the application is stored in a portion of memory that can be over-written with downloads of new software. The boot code has the responsibility of deciding if the
resident application software image should be allowed to execute.

800021-01 Rev. B

32

wegener.com

DTV 735 User’s Manual

Initialization
Sequence

At power up, the boot loader software executes first. It performs a test of RAM
and then relocates itself for further execution from there. During boot-up, the
following screens appear in sequence on the LCD:
FPCon

v001

All front-panel LEDs light are
OFF during boot process.

Hit key to stop boot
Booting in 2
Booting System
Bootloader Ver 101
Done Booting
Bootloader Ver 101
Following normal boot-up, the "home" screen will appear as described in section 3.4 Front-panel Operation on page 26 and the LEDs reflect the actual
state of the unit.
Initialization
Failure

When in Initialization Failure mode, the unit is essentially dead. There is no
ASI output, the alarm relay is de-energized (alarm state), the alarm LED is ON,
and the unit does not attempt acquisition of input streams. Call Wegener Customer Service.

3.6 Transport Stream Processing
Refer to ISO 13818-1 for supporting details on the structure of MPEG Transport Streams.
Input to
Output
Processing

The basic DTV735 has an ASI input and two duplicate ASI outputs. The unit
processes the input, selects programs based on user input, and provides an output signal on the DHEI and ASI outputs. The processing includes program
number changes as selected. Based on user selection, certain programs may be
selected and then passed to the ASI output with time stamping updated.

PSIP
Structure and
Program
Selection

Within the transport stream there are PIDs carrying tabular information on that
stream. The PAT describes all the programs available. The program number
identifies each program in the transport stream. When a source of data is
acquired, the stream is passed to the internal transport demultiplexer. This circuit then extracts the PAT and PMT information and provides this information
to the user via the Stream Info and Configuration pages of the web interface.
The user may then select programs to be included in the ASI output as
described in section 3.2 Ethernet/Web Browser Control.

wegener.com

33

800021-01 Rev. B

DTV 735 User’s Manual

IRT Mode

With systems using the Motorola IRT product, certain additional elements
must be included in the output transport stream. In such systems, be sure to
enable the DTV 735’s IRT Mode by selecting IRT Mode ON from the web
browser interface or front panel (see Control and Status Page on page 19).
When the IRT Mode is on, the DTV735 performs the actions listed here.
•A CAT (Conditional Access Table) PID (0x0001) is included and a CA
system descriptor is added in this packet pointing to a reserved location
(PID 0x0ff9) for the EMM (Encryption Management Message).
•For each program in the stream, a CA descriptor pointing to itself is added
in the PMT. This is a null ECM (Encryption Control Message).
•To the PAT, Program 0 (NIT) is added, pointing to PID 0x0ffe which
carries the STT (System Time Table) clock information.
•The NIT (Network Information Table) must also be present in the
transport stream. This PID (0x0ffe) is created at the uplink and is passed
through.

3.7 Alarm System
The alarm and warning system is intended to provide indications to local user
of a critical failure or imminent failure. See Table 6: LED Indicator Descriptions on page 25 for actual indications.
Alarm
Conditions

Generally, if the unit is unable (or presumed to be unable) to present output
from a selected transport stream, then that is an alarm state. The following list
defines all alarms during normal operation (also see Initialization Failure on
page 33).
1. ASI Input Unlocked – A valid ASI stream is not present on ASI Input 1.
2. Unit oversubscribed – The combined data rate of the input programs
selected exceeds the output data rate selected.
3. PAT missing – The Transport Steam on the input does not have a PAT
present (should be located in PID 0x01.
4. PMT missing – The Transport Steam on the input does not have a PMT
present (should be located in PIDs as shown in the PAT).

3.8 Software Downloads
The DTV735 may be field upgraded with new application software. Contact
Wegener Customer Service for more information.

800021-01 Rev. B

34

wegener.com

Chapter 4 Maintenance and Troubleshooting
4.1 Maintenance
Maintenance of the DTV735 is limited to keeping the chassis clean and ensuring that cables remain firmly connected. Occasionally wipe the exterior with a
soft, damp cloth to remove any accumulated dust and dirt and check that cables
are securely attached.

The DTV735 incorporates security labels over some of the screws. There are
no user-serviceable components within the DTV735. Tampering with the security labels or opening the unit will void your warranty. If you have any questions, contact Wegener’s Customer Service Department at the address or
numbers listed under Customer Service.

4.2 General Troubleshooting
This section is not an intended as an exhaustive list of all possible situations.
Please contact us as directed in Chapter 5 Customer Service on page 39, with
any problems you cannot resolve independently.
If you are experiencing any difficulties, first check the LCD and LED indicators on the DTV735 to determine if any warnings or alarms are active. See
Table 6: LED Indicator Descriptions on page 25 for descriptions of LED
states. If operating over the Ethernet interface, check the Control and Status tab
on your browser for Warning messages.
No functions
at all

If the unit is not functioning at all and neither the LCD nor any LEDs are
active, there may be a loss of ac power. Do the following:
a) Check that ac power cord is firmly connected at both ends.
b) Check that your ac power source is supplying ac power.

wegener.com

35

800021-01 Rev. B

DTV 735 User’s Manual

4.3 Alarms
In the following sections, LEDs are illustrated as black (off) or white (on) to
represent actual LED appearance.

Normal
Operation

ASI Input and ASI Output Locked - The LEDs are shown here reflecting
the DTV735 in normal operation with no Alarms:

ALARM: ASI
Input
Unlocked

Video is lost when the incoming signal is lost. When the ASI IN LOCK LED is
inactive or unlit (shown below), the ASI transport stream sync has been lost.
The WARNING LED will light if both ASI input (1 or 2) and RF input are
selected and RF CARRIER LOCK remains. Check ASI source and input connection.

800021-01 Rev. B

36

wegener.com

DTV 735 User’s Manual

ALARM:
Unit Oversubscribed

An oversubscription alarm means that the total rate of the selected ASI inputs
is greater than the selected output rate. A corrupt signal is output from the
DTV735. Oversubscription results in errors in the video output. On the front
panel, this is indicated by a lit ALARM LED and an unlit ASI OUT LOCK
LED (shown below). Solve the problem by reducing the number of input programs to fit the combined input data rate within the selected output data rate.

ALARM:
PAT or PMT
Missing

Video is lost when the incoming signal is missing either the PAT or PMT.
When the ALARM LED is lit and both the ASI 1 LOCK and the ASI OUT
LOCK LEDs are lit then the transport stream does not have sufficient PSI
information included. Check with the service provider to insure that the source
is correct.

4.4 Trouble with Browser Interface
If the unit appears to be functioning normally with no alarm or warning conditions, but you cannot use the web browser interface, first check the LED on the
rear panel next to the Ethernet connector. It will illuminate and blink as LAN
data are detected. If this LED is off check the cabling to the LAN. If the LED
remains off after verifying the LAN connection, contact Customer Service. If
the Ethernet LED is illuminated, check that you are using the correct IP
address. (See “Ethernet/Web Browser Control” on page 17.)
If the address is correct, but the interface still does not function, check your
computer’s IP settings and consult your network administrator for additional
help.

wegener.com

37

800021-01 Rev. B

DTV 735 User’s Manual

This page intentionally blank

800021-01 Rev. B

38

wegener.com

Chapter 5 Customer Service
5.1 Warranty
The following warranty applies to all Wegener Communications products
including the DTV735 Digital Television Processor:
All Wegener Communications products are warranted against defective materials and
workmanship for a period of one year after shipment to customer. Wegener
Communications' obligation under this warranty is limited to repairing or, at Wegener
Communications' option, replacing parts, subassemblies, or entire assemblies. Wegener
Communications shall not be liable for any special, indirect, or consequential damages.
This warranty does not cover parts or equipment which have been subject to misuse,
negligence, or accident by the customer during use. All shipping costs for warranty repairs
will be prepaid by the customer. There are no other warranties, express or implied, except
as stated herein.

5.2 Technical Support
In the event that the unit should fail to perform as described, or if you need
help resolving problems with your DTV735, contact Wegener Communications Customer Service at (770) 814-4057, FAX (678) 624-0294, or E-mail service@wegener.com.
To return a product for service:
a) Obtain a Return Material Authorization (RMA) number by completing
and faxing a copy of the RMA Request Form to (678) 624-0294. You
may E-mail the same information instead to: service@wegener.com
b) To help us identify and control returned units, plainly write the RMA
number on the outside of the product-shipping container. This will help
us return your unit to you as quickly as possible.
c) Return the product, freight prepaid, to the address below:
Service Department RMA# ________
Wegener Communications, Inc.
359 Curie Drive
Alpharetta, GA 30005

NOTE:All returned material must be shipped freight prepaid. C.O.D.
Shipments will not be accepted.
Please contact Customer Service at the number above if you have any questions about obtaining service for your DTV735.

wegener.com

39

800021-01 Rev. B

DTV 735 User’s Manual

This page intentionally blank

800021-01 Rev. B

40

wegener.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2003:12:05 20:26:31Z
Modify Date                     : 2004:02:03 11:42:58-05:00
Subject                         : DTV735 Digital Television Processor
Keywords                        : DTV735, DTV, 735
Page Count                      : 40
Creation Date                   : 2003:12:05 20:26:31Z
Mod Date                        : 2004:02:03 11:42:58-05:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Wegener Communications, Inc.
Metadata Date                   : 2004:02:03 11:42:58-05:00
Creator                         : Wegener Communications, Inc.
Title                           : DTV735 Digital Television Processor (Fox Version) User's Manual
Description                     : DTV735 Digital Television Processor
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
EXIF Metadata provided by EXIF.tools

Navigation menu