Hyundai Solar Inverters
Internationally Recognized Clean Energy Solution

HYUNDAI HEAVY INDUSTRIES
HYUNDAI; Leading Green Company
Hyundai is designing and developing Solar Inverters. We focus on researching, designing, developing and
manufacturing Solar Inverters for world market.
We will continuously try to give customers full satisfaction with high level of service and product performance.

HYUNDAI Solar Inverter; Global Standard Application
Hyundai’s marketing and sales target are worldwide. We acquired variety of certificates for major European
and Asian countries.
Customers can experience global standard Solar Inverter performance by choosing Hyundai Solar Inverter.

Total Solar Solution; Full Line-Up
Hyundai is providing total solution for solar power plant including Solar Inverter, Solar Module
and Solar Monitoring System.
Customers can experience the utmost solar power plant performance through Hyundai's
optimized total solar solution.

Transformer-less Type >

HPC-004SL

HPC-100HL-E

HPC-125HL-E

HPC-250HL-E

HPC-500HL-E

www.hyundaisolar.com

< Low-Frequency Transformer Type

HPC-050HT-E

HPC-100HT-E

HPC-250HT-E

Solar Station 500 kW

Solar Station 1 MW

HYUNDAI Solar Inverters
Clean, Renewable,
Reliable Solar Energy
Power Conversion System (Inverter) converts DC power
produced by solar arrays into AC power.
Solar Inverters are consisted of three parts: DC/DC Converter,
Power Stack, and Controller.
Grid-Tied Solar Inverters have been developed using the most
advanced technology and design techniques.

▶ Features
• Compact design, lightweight, and easy to install
• Maximum efficiency with high performance MPPT control
• Increased flexibility due to a wide range of MPPT tracking
• Remote and local data monitoring
• LCD display of operating status
• Anti-islanding protection
• Issued CE and TÜV certificate, ENEL 2009 certificate,
MEA & PEA (Thailand) certificate, RD1663 certificate
(50 kW, 100 kW and 250 kW class)
• Support 5 year standard warranty + 20 year extended warranty

Technical Specifications & Product Overview
| Transformer-less Type |
Specifications
Model

System Overview

Phase
Output Operating
Method

HPC-004SL
(for Japan)

HPC-100HL-E

HPC-125HL-E

HPC-250HL-E

HPC-500HL-E

1-Phase

3-Phase

3-Phase

3-Phase

3-Phase

Grid-Tied
Inverter

Grid-Tied
Inverter

Grid-Tied
Inverter

Grid-Tied
Inverter

Grid-Tied
Inverter

Output Data

Input Data

Design Concept

Transformer-less

Max. Input Voltage

380 Vdc

880 Vdc

880 Vdc

900 Vdc

900 Vdc

Nominal Voltage

250 Vdc

635 Vdc

635 Vdc

650 Vdc

650 Vdc

100~380 Vdc

450~820 Vdc

450~820 Vdc

450~820 Vdc

450~820 Vdc

Max. Input Current

25 Adc

234 Adc

292 Adc

625 Adc

1,140 Adc

Nominal AC Power

4 kW

100 kW

125 kW

250 kW

500 kW

Nominal AC Voltage

202 V, ±12 V

Nominal AC Current

19.8 A

MPPT Voltage Range

System Specifications

199 A

Nominal AC Frequency

249 A

270 V, +10 %/-12 %
540 A

1,070 A

50 Hz/60 Hz
< 5 % Total (< 3 % Individual) at rated power

THD of AC Current

Dimensions

290 V, +10 %/-12 %

Max. Efficiency

95.6 %

98.5 %

98.5 %

98.5 %

98.6
98.5 %

European Efficiency

94.9 %

97.7 %

97.7 %

97.6 %

98.2 %

Power Factor

> 0.99

> 0.99

> 0.99

> 0.99

> 0.99

IP20

IP20

IP20

IP20

IP20

Operating Temperature

-10˚C~ 40˚C

-10˚C~ 40˚C

-10˚C~ 40˚C

-20˚C~ 45˚C

-20˚C~ 45˚C

Width/Depth/
Height [mm]

480/120/280

1,000/800/2,095

1,000/800/2,095

1,800/750/2,150

2,600/800/2,080

14 kg

620 kg

620 kg

1,120 kg

1,550 kg

Protection Degree

Weight

Protective Functions

DC Over-/Under-Voltage, AC Line Over-/Under-Voltage, AC Line Frequency Failure,
AC Line Failure, Anti-Islanding Protection, Overheating

※ Specifications subject to change without prior notice.

Technical Specifications & Product Overview
| Low-Frequency Transformer Type |
Specifications

Output Data

Input Data

System Overview

Model

HPC-050HT-E

HPC-100HT-E

HPC-250HT-E

Phase

3-Phase

3-Phase

Output Operating
Method

Grid-Tied
Inverter

Grid-Tied
Inverter

Design Concept

System Specifications

HPS-500MT-E

HPS-1000MT-E

3-Phase

3-Phase

3-Phase

Grid-Tied
Inverter

Grid-Tied
Inverter

Grid-Tied
Inverter

Low-Frequency Transformer

Medium Voltage Transformer

[△-Y]

[△-Y]

[Y-△]

Max. Input Voltage

650 Vdc

650 Vdc

880 Vdc

900 Vdc

900 Vdc

Nominal Voltage

450 Vdc

450 Vdc

635 Vdc

650 Vdc

650 Vdc

300~600 Vdc

300~600 Vdc

450~820 Vdc

450~820 Vdc

450~820 Vdc

Max. Input Current

175 Adc

350 Adc

580 Adc

2 x 625 Adc

2 x 1,140 Adc

Nominal AC Power

50 kW

100 kW

250 kW

500 kW

1,000 kW

MPPT Voltage Range

Nominal AC Voltage
Nominal AC Current

400 V, +10 % /-12 %
72 A

144 A

Nominal AC Frequency

20 kV, +10 %/-12 %
361 A

14.4 A

28.9 A

50 Hz / 60 Hz

THD of AC Current

< 5 % Total (< 3 % Individual) at rated power

Max. Efficiency

95.8 %

96.7 %

96.9 %

97.0 %

97.0 %

European Efficiency

95.0 %

96.3 %

96.2 %

96.5 %

96.5 %

Power Factor

> 0.99

> 0.99

> 0.99

> 0.99

> 0.99

IP20

IP20

IP20

IP54

IP54

-10˚C~40˚C

-10˚C~40˚C

-20˚C~40˚C

-20˚C~45˚C

-20˚C~45˚C

800/700/1,994

1,000/800/2,095

800 kg

1,250 kg

Protection Degree
Operating Temperature
Width/Depth/
Height [mm]

Dimensions

Solar Station

Weight

Protective Functions

2,200/850/2,215 5,300/3,000/3,100

2,350 kg

Approx. 28 t

5,600/3,000/3,100

Approx. 32 t

DC Over-/ Under-Voltage, AC Line Over-/ Under-Voltage, AC Line Frequency Failure,
AC Line Failure, Anti-Islanding Protection, Overheating

※ Specifications subject to change without prior notice.

Monitoring System
Clients can monitor the Hyundai solar system through proposed monitoring system (optional).
Environments, Solar inverter status, Solar module status, Power generating system status can be monitored.

Temperature
Sensor
- Ambient Temperature
- Module Temperature

Wind Sensor
- Wind Speed

Radiation
Sensor
- Radiation Intensity

SString
i C
Connection
i B
Box
- Solar array status monitoring
- Error Analysis

Solar Inverter
- Power Conversion
- Protective Functions

Web Application
- Identify faults
- Damage scope analysis
- Reporting:
system comparison
fault-overview
- Alerts: email or SMS
- Languages:
English, German, Spanish,
Italian, French, Czech,
Polish, Hebrew

Internet

Remote Monitoring

Local Monitoring

Communication Box
- Failure monitoring
- Reporting
- Messaging: email/SMS
- Data logging
- Large data volume
- Error analysis

www.hyundaisolar.com
HEAD OFFICE
1000, Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea
Tel : 82-52-202-8101~8 Fax : 82-52-202-8100

RIYADH
Office 230, 2nd Fl., The Plaza Center, Pobox 8072, Riyadh 11485, Saudi Arabia
Tel : 966-1-464-4696, 9366 Fax : 966-1-464-2352

SEOUL (SALES & MARKETING)
12th Fl., Hyundai Bldg.75, Yulgok-ro, Jongno-gu, Seoul 110-793, Korea
Tel : 82-2-746-8406, 7422, 8525 Fax : 82-2-746-7675 E-mail : hyundaisolar@hhi.co.kr

DUBAI
205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox 252458, Dubai, UAE
Tel : 971-4-425-7995 Fax : 971-4-425-7996

ATLANTA
6100 Atlantic Boulevard, Norcross, GA 30071, U.S.A.
Tel : 1-678-823-7839 Fax : 1-678-823-7553

MOSCOW
World Trade Center, Ent. 3, #1902, Krasnopresnenskaya Nab. 12, Moscow, 123610, Russia
Tel : 7-495-258-1381 Fax : 7-495-258-1382

LONDON
2nd Fl., The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UK
Tel : 44-20-8741-0501 Fax : 44-20-8741-5620

MADRID
Paseo de la Castellana 216, Planta 0, 28046 Madrid, Spain
Tel : 34-91-732-0454 Fax : 34-91-733-2389

TOKYO
8th Fl., Yurakucho Denki Bldg. 1-7-1, Yuraku-cho, Chiyoda-ku, Tokyo, 100-0006, Japan
Tel : 81-3-3211-0742~4 Fax : 81-3-3211-2093

Hyundai Ideal Electric Company
330 East First Street Mansfield OH 44902, U.S.A.
Tel : 1-419-522-3611 Fax : 1-419-522-9386

OSAKA
I-Room 5th Fl., Nagahori Plaza Bldg. 2-4-8, Minami Senba, Chuo-ku, Osaka, 542-0081, Japan
Tel : 81-6-6261-5766~7 Fax : 81-6-6261-5818

Hyundai Technologies Center Hungary Ltd.
1146, Budapest, Hermina Ut 22, Hungary
Tel : 36-1-273-3730, 3733 Fax : 36-1-220-6708

A/S Network
SINGAPORE
7 Temasek Boulevard, #41-02 Suntec Tower One 038987, Singapore
Tel : 65-6337-2366 Fax : 65-6337-8966

PARIS
Hyundai Corporation - 5TH Fl., 90 Avenue Champs - Elysee, 75008, Paris, France
Tel : 33-1-4225-2100 Fax : 33-1-4225-2101

MUMBAI
Hyundai Heavy Industries Co.,Ltd. - Mumbai Liaison Office
5th Fl., East Quadrant, The IL&FS Financial, Centre, Plot No. C-22, G-Block, Bandra-Kurla,
Complex, Bandra(E), Mumbai 400 051, India
Tel : 91-22-2653-3420~26 Fax : 91-22-2653-3429~30

NEW-DELHI
Hyundai Corporation, New Delhi Liaison Office - Plot No. D-2, Southern Park, Saket
District Centre, New Delhi
Tel : 91-11-4168-9111, 2, 3 Fax : 91-11-4168-9120

FRANKFURT
Hyundai Corporation Europe Gmbh - Mergenthaler Allee 77, D-65760 Eschborn/TS,
Germany
Tel : 49-6196-9008 Fax : 49-6196-9008~12, 17

SYDNEY
Hyundai Australia Pty., Ltd. - Suite 504, Level 5, 815 Pacific Highway, Chatswood, N.S.W.
2067, Australia
Tel : 61-2-9413-2314 Fax : 61-2-9413-1965

Printed Date : July 2012



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2012:07:16 15:59:24+09:00
Creator                         : Adobe InDesign CS3 (5.0.4)
Modify Date                     : 2013:02:13 18:23:52+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Instance ID                     : uuid:19f6a175-3a72-4019-b32e-93496dd696d9
Document ID                     : adobe:docid:indd:8c8d2bdb-b240-11e1-8299-c1a50217ff7a
Rendition Class                 : proof:pdf
Derived From Instance ID        : 6cac0c57-b218-11e1-8299-c1a50217ff7a
Derived From Document ID        : adobe:docid:indd:e0523741-a273-11e1-bfe9-fea1b1de57fb
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:9ABBA25EB7A411E1B143A29ECD393632, uuid:9ABBA25EB7A411E1B143A29ECD393632, uuid:494CD0B7BBC211E1B055A55D8D2CFE8C, uuid:494CD0B7BBC211E1B055A55D8D2CFE8C, uuid:22F83335D0F111E183FAC564BC04BF24, uuid:BA76D59F878C11E098369C387B782174, uuid:6D87BB7783B811E0A5B19725680B61A5, uuid:2B017A1983B811E0A5B19725680B61A5, uuid:CB066E74878C11E098369C387B782174, uuid:4E9BD03BBC5211E19EA0CC58667C1409
Manifest Reference Document ID  : uuid:9692AB78B7A411E1B143A29ECD393632, uuid:9692AB78B7A411E1B143A29ECD393632, uuid:494CD0B6BBC211E1B055A55D8D2CFE8C, uuid:494CD0B6BBC211E1B055A55D8D2CFE8C, uuid:22F83334D0F111E183FAC564BC04BF24, uuid:6D87BB7683B811E0A5B19725680B61A5, uuid:D59F61E786AA11DFADAEC35A691CD129, uuid:F7D99A8483B711E0A5B19725680B61A5, uuid:5A8402B3B65211E18E3AD4BF388AAA31
Metadata Date                   : 2013:02:13 18:23:52+09:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9316 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu