91pdp00_e 91PDP_E 91PDP E
User Manual: 91PDP_E
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
PCS 91.PDP english Reg 5075/0597ss One does not refer in the manual explicitly to the devices of the PCS plus/win series, the description applies to all devices. With differentiations between the equipment series the following allocations apply: PCS topline = micro/mini: PCS 009, PCS 090, PCS 095, PCS 095.1, PCS 095.2 midi: PCS 900, PCS 950, PCS 950c, PCS 950q, PCS 950qc, maxi: PCS 9000/9100 PCS plus = micro/mini: PCS 009 plus, PCS 090 plus, PCS 095 plus midi: PCS 950 plus, PCS 950c plus, PCS 950q plus, PCS 950qc plus PCS win = micro/mini: PCS 009 win, PCS 090 win, PCS 095 win midi: PCS 950 win, PCS 950c win, PCS 950q win, PCS 950qc win CiS-Nr.: 360.110.0390 Version 2/02.03 © Systeme Lauer GmbH & Co KG Systeme Lauer GmbH & CoKG Postfach 1465 D-72604 Nürtingen Operator reference manual: PCS 91.PDP Version: 31. Januar 2003 Person responsible: Zoch Operating manuals, reference manuals, and software are protected by copyright. All rights remain reserved. The copying, duplication, translation, conversion in the whole or into parts are not permitted. An exception applies to making a copy of the own use. • We reserve the right make changes to the reference manual without prior notice. • We can not guarantee the accuracy of the programs and data stored on the diskette and the fault-free state of this information. • Since diskette represent manipulatable data media, we can only guarantee the physical completeness. The responsibility is limited to a replacement. • At any time, we welcome suggestions for improvements and remarks on errors. • The agreement also applies to the special appendices to this reference manual. Microsoft, MS, MS DOS, Windows, Windows 95, Windows NT and the Windows logo are either registered trademark or trademarks of the Microsoft Corporation in the USA and/or other countries. SIMATIC and STEP are registered trademarks of the Siemens AG. The remaining designations in this document can be brand names who`s use by parties for their purposes can violate the rights of the owners. 0-2 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 Notes for the user Please read the manual before beginning and keep the manual for later use. Target group The manual has been conceived and written for users who are experienced in the use of PCs and automation technology. Typographical conventions [KEY] Keys that are to be pressed by the user are given in square brackets, e.g [CTRL] or [DEL] Courier On-screen messages are given in the Courier font, e.g. C:\> Courier bold Keyboard input to be made by the user are given in Courier bold, e.g. C:\>DIR Italics Names of buttons to be pressed, menus or other on-screen elements and product names are given in italics. Pictograms The manual uses the following pictograms to highlight certain text passages: Danger! Possibly dangerous situation. Injury to persons can be the result. Attention! Possibly dangerous situation. Property damages can be the result. Tips and supplementary notes © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 0-3 Table of contents Notes for the user 0-3 Table of contents 0-4 Quality and support 0-5 Safety regulations 0-6 Norms 0-7 About what does this manual report? 0-8 Which parts do I need? .......................................................... 0-8 0-4 A General remarks A-1 A.1 Basic data interchange .................................................... A-1 A.1.1 Settings of the Multibox slave ......................................... A-3 A.1.2 Parameterizing of the PCS .............................................. A-4 A.1.3 Transfer of the record into the PCS ................................. A-5 A.1.4 Set-up and first powering-up ............................................ A-5 A.1.5 PCS 807 Specifications .................................................. A-6 B Siemens PLC B-1 B.1 Determining the configuration .......................................... B-3 B.1.1 Configuration of the master board (S5) ............................ B-4 B.1.2 Configuration of the L2-DP network (S7) .......................... B-7 B.1.3 Defining a master system ............................................... B-8 B.1.4 Programming of the programmable controller ................ B-11 B.1.5 Settings of the slave Multibox ....................................... B-12 B.1.6 S5 demo project ............................................................ B-13 B.1.7 Trouble-shooting ............................................................ B-14 B.1.8 Term of the communication ........................................... B-15 B.1.9 Optimal configuration .................................................... B-17 C Bosch PLC C-1 C.1 Determining the configuration .......................................... C-3 C.1.1 Configuration of the master board (DESI-DP) .................. C-3 C.1.2 Trouble-shooting .............................................................. C-6 C.2 Print out handling software .............................................. C-9 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 Quality and support In our company, quality comes first. From the electronics component up to the finished device, the quality assurance test competently and comprehensively. National an internation test standards (ISO, TÜV, Germanischer Lloyd) are the basis. Within 48 hours, every device passes a 100% check and continuous test under worst case conditions at changing temperatures (0...50°C) and test voltages. A guarantee for maximum quality. Our products not only feature a maximum economic efficiency and reliability but also a comprehensive complete service. You not only receive demo devices but we rather make specialists available who support you in person with your first application. Qualified user consultation by competent sales engineers is obvious for us. Our support is for you for the side with advice and deed every day. We set up training programs and technical training for you in our modern training center or alternatively also in your house. Request the curent training catalog. From the consultation up to the user support, from the hotline up to the service, from the reference manual up to the training an all covering and individual service for the entire product line is waiting for you. Whenever you need us, we are there for you: dynamically, creatively and enormously efficiently. With the entire experience of a world-wide successful enterprise. Telephone eMail Web site 07022/9660-132, -231, -230 support@systeme-lauer .de www.lauer-systeme.net Systeme Lauer Active Area (Download of Software, driver, manuals, Forum...) © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 0-5 Safety regulations This reference manual contains the most important remarks in order to safely operate the device. 0-6 • This operator‚s guide, particulary the safety remarks are to be noted byall persons working with the device. • Furtherrmore, the rules and regulations for the accident prevention applying to the application location are to be observed. • Use as directed. The device is deigned for the application in the industrial area. • The device is manufactured to the state of the art and the official safeguarding regulations. Nevertheless, due to the application, dangers or impairments can result to the machine or to material assets. • The device meets the requirement of the EMC guidelines and harmonized European standards. Any hardware-related modification of the system can influence the EMC behavior. • The device may not be used without special protective measures in the hazardous area and in plants requiring a special monitoring. • Do not heat up the buffer batteries. Danger of explosion. Serious burning can be the result. • The installation and operation may only be performed by trained personnel. • The operating voltage of the device may only be in the specified ranges. • You find information on this on the type plate and in the specifications of this reference manual. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 Norms The device is constructed using up-to-date technologies and fulfils the requirements of the following guidelines and norms: • Compliant with the EMC Directive 89/336/EEC and the German law on electro-magnetic compatibility • Interference compliant with the generic requirements norm EN 500812 and product norm EN 55022: • Measurement of the conducted interference voltage as per EN 55022 • Measurement of the radiated radio interference field power as per EN 55022 class A • Interference immunity in compliance with generic requirements norm EN 50082-2 and product norm EN 61000-6-2: - Electro-static discharge (ESD) as per with EN 61000-4-2 - High-frequency electromagnetic fields as per EN 61000-4-3 and ENV 50204 - Fast transient interference (burst) as per EN 61000-4-4 - Surge voltages as per EN 61000-4-5 - High-frequency conducted fields as per EN 61000-4-6 - Voltage dips and short-term interruptions as per EN 61000-4-11 The assembly and connection instructions contained in this documentation must be followed. Conformity of this equipment is confirmed by the CE logo. The EC declaration of conformity can be requested from: Systeme Lauer GmbH & Co KG P-O-Box 1465 D-72604 Nürtingen © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 0-7 About what does this manual report? This manual informs you exclusively about the application of the PCS 807 Profibus DP Multibox together with the PCS micro, mini/VPC 090 Multi Interface, the SIEL2DME.DRV midi and maxi driver and the programmable controller handling software PROFIBUS.S5D or PCSS7L2.AWL (S7). The PCS 590/595p operating consoles do not require the PCS 807 Multibox since this is integrated into the PCS 590p/595p. The settings of the master board and the use of the handling software is absolutely identical. Therefore, this principle is used for the here described procedure. The network structure set-up was tested with a S5-115U (CPU 942, 943, 944, 945), an S5-135U (CPU 928) in connection with an IM308B (version 6) S5 DP master board, an IM308C (version 2), and a CP5431 (version 3). The setup was also tested with an S7 fitted with a CPU 315-2 DP. The following describes the startup of this set-up. The PCS 807 firmware is based on the Siemens SPC-3 chip set with Siemens object code. Systeme Lauer can take over no responsibility for errors and limitations due to the Siemens software. Programming of the Siemens programmable controllers, of the Profibus master board, and the basic Profibus DP functions are assumed as known. Which parts do I need? The following products are required from Systeme Lauer for a Profibus DP network set-up: • PCS807 Profibus DP Multibox, version PX807 0001 (SPC2), or PX807 1000 (SPC3), or higher. • A PCS micro, mini, midi, or maxi operating console or the VPC 090 Multi Interface. • The PCSPRO, PCSPROWIN/PCSPROPLUS or PCS 9092 configuration software and a PCS 733 programming cable for the PCS operating console. • This manual including the PCS91.PDP floppy disk. ....as well as power supplies for all components. 0-8 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A General remarks A.1 Basic data interchange The communication connection between the PCS and the programmable controller data area is made via the following communication devices: PCS operating console À (PCS807 Multibox) Profibus DP À Profibus master À Programmable controller À Profibus master À (PCS807 Multibox) Profibus DP À PCS operating console Operating console PCS busline SPS Operating console PCS ProfibusMaster ○ ○ ○ ○ ProfibusDP network cable ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ to further participants ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ COMInterface ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A-1 A General remarks PCS operating console The PCS operating console determines the tasks to be executed (according to the network configuration, the enables, the display content, and the keys) and sends these in one package to the PCS 807 Multibox Profibus DP slave. The PCS 807 Multibox Profibus DP slave passes the package on to the Profibus master. À The master stores the package in the I-area of the programmable controller. À Programmable controller The communication data block is located in the programmable controller and occupies 256 words (e.g. DB50). The tasks input buffer is located in an I-area of the programmable controller. The tasks response buffer is located in an O-area of the programmable controller. A cyclically selected handling block (FB203) executes the tasks present in the I-buffer on the data block and stores the result in the O-buffer. À The master picks up the response package from the O-area of the programmable controller and submits it to the slave. À The PCS 807 Multibox Profibus DP slave submits the response to the PCS. À PCS operating console The PCS operating console evaluates the response and shows the data on the display. The inquiry/response package is supplied with a task number so that the response always matches the inquiry. With the PCS 590p/595p and the PCS plus/win, the intermediate steps referring to the PCS 807 Multibox are skipped. The master communicates directly with the PCS. A-2 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A General remarks A.1.1 Settings of the Multibox slave The PCS 807 Multibox Profibus DP slave automatically adapts to the given configuration. For this, only the slave number of the PCS 807 Multibox Profibus DP needs to be set. Using the DIL-switches 1 to 7, you can set the slave number of the PCS 807 Multibox Profibus DP between 3 and 127. The settings must be performed either with the power being removed or in the reset state (the settings are taken over at the start). The slave address is calculated as follows (OFF = 0 and ON = 1): DIL1 x 64 + DIL2 x 32 + DIL3 x 16 + DIL4 x 8 + DIL5 x 4 + DIL6 x 2 + DIL7 x 1 Slave-Nr DIL 1 DIL 2 DIL 3 DIL 4 DIL 5 DIL 6 DIL 7 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 5 OFF OFF OFF OFF ON OFF ON 6 OFF OFF OFF OFF ON ON OFF 7 OFF OFF OFF OFF ON ON ON 125 ON ON ON ON ON OFF ON 126 ON ON ON ON ON ON OFF ... The slave number of the PCS 590p/595p and PCS plus/win is set in the driver using the PCSPRO configuration software. Select the Project menu item and then Driver parameters. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A-3 A General remarks A.1.2 Parameterizing of the PCS Both, the application program with data and a selected driver is transferred when configuring the PCS. The presettings of the variable can be changed for optimizing the driver. Variable AJ - number of tasks per package Using this variable, the number of tasks per task package can be influenced. Thus, this variable is influenced by the size of the I/O buffer. Furthermore, the refresh of the variable and the refresh of the keys/LEDs is offset by this value. The relation is explained best using an example: AJ = 1 --> Keys and LEDs will be quickly transferred, variables are refreshed slowly - suited for jog operation. The I/O buffer can be small. AJ = 10 --> Default values. Represent a balance between the key and the variable refresh. AJ = 20 --> Keys and LEDs will be transferred simultaneously with variables suited for the display of many variables. The I/O buffer should be as large as possible. AA variable - Time-out time The time-out time to be set is related to the maximum time that is required by the programmable controller for the cyclical call of the communication program plus the communication time. The time is adjustable in the range of 2 and 9.9 seconds - default is 4 second. Time monitoring is activated only if the task read by the PCS is not yet the current one. In addition, the PCS 590p/595p and PCS plus/win features the following variables: AH variable - PCS station number Here, the slave station number of the Profibus DP slave is set. The value range is 3 (default value) to 127. BC variable - Direct key values You can reserve 0 2 words of the programmable controller I/O area for the direct transfer of keys. These keywords are then constantly assigned to the key bits and are directly to be evaluated. The key transfer time is significantly faster compared to the PCS transfer since no interpretation of the data is required. You can use these key words for jog operations. Assumed, you have reserved 16 bytes from I20 to I35 for slave 3 that is a PCS 590p/595p.The key words are assigned to I20 to I23 if you have set 2 key words. These words are now lost for the PCS Expander communication: set the start of the Expander (e. g. RXFA) to 24 and the length (e. g. RXLE) to 12. Please note that you can only reserve one word for direct keys of an input area having a size of eight bytes. BD BG variables - Contents of the key bytes Using five instances, you can assign the key words of each byte a certain information (key bits). Please refer to the PCS 591/PCS 096 manual for further information on key bytes. A-4 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A General remarks A.1.3 A.1.4 Transfer of the record into the PCS 1. Set DIL-switch 8 on the rearside of the PCS to „OFF“ and DILswitches 9 to „ON“. (Not with the PCSmaxi) 2. Apply operating voltage (19 ... 33V) to the PCS. The ERR-LED is now ON. 3. Connect the programming interface of the PC with the PCS operating console using the PCS 733 programming cable. 4. Run the PCSPRO/PCSPROWIN/PCSPROPLUS configuration software. 5. Select the Profibus DP driver for your PCS. 6. Create or load your data file. 7. Set the driver parameters using the menu items „Options“ and „Drivers“. You can take over the default settings in the normal case. 8. Transfer the compiled record into the PCS. Set-up and first powering-up Disconnect the supply voltage to the set-up when you have configured all parts. Thereby, the following points are to be considered: Profibus DP network • Use only suited cable for the wiring. • The last participant in the Profibus DP network must have a terminator. Use the Siemens SINEC L bus connector for this. Special bus connectors are required for baud rates between 3 and 12 MHz (Siemens part number: 6ES7 972-0BA10-0XA0). Instead of the Siemens connectors you can also use the supplied Lauer terminals between PCS 807 Multibox Profibus DP slaves (only recommended up to 500Kbaud). When using the Lauer terminals, the red wire is connected to „A“ and the green wire to „B“. The cable screening is connected to the cable clip (not with the PCS 590p/595p and PCS plus/win). Proceed as follows for powering-up: • Supply power to the programmable controller and to the PCS 807 Multibox Profibus DP. • The „SEND“ LED of the master board is activated after a maximum time of 5 seconds. Then, the green „COM“ LED of the PCS 807 Multibox or of the PCS 590p/595p lights statically. • Now, connect the PCS (COM interface) to the PCS 807 Multibox Profibus DP (not the PCS 590p/595p). • Set the restart input of the programmable controller to „ON“ or switch the programmable controller from STOP to RUN. • The „COM“ LED of the PCS is deactivated after a maximum time of 2 seconds. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 A-5 A General remarks View Pin Signal name Designation 1 2 - - 3 RxD/TxD-P data line - B 4 RTS request to send 5 M5V2 data reference potential (from the station) 6 8 P5V2 power supply plus (from the station) RxD/TxD-N data line - A Mechanical mounting of the PCS 807 Multibox Profibus DP The PCS 807 Multibox Profibus DP can be mounted on a top hat rail (DIN rail). The PCS operating console and the PCS 807 Multibox Profibus DP must be earthed! A.1.5 PCS 807 Specifications Description PCS 807 Multibox Profibus DP slave System requirements Standard Profibus DP network according to DIN 19245 System assignments • • Mounting dimensions height: width: length: Supply voltage Current consumption 24 volts ± 10 % 200 mA max. Power consumption 5 VA max. Operating temp. range 0 ... +50° C Storage temp. range - 20 ... +80° C Interfaces RS-232 interface with 25-pin sub D female connector to the PCS operating console RS-485 interface with 9-pin sub D male connector RS-485 interface with 8-pin terminal strip and 24 volts supply voltage • 1 yellow LED for supply voltage • 1 yellow LED for LOAD/RUN state • 1 green LED for communication state Indicators DIL-switches A-6 min. 8 bytes in the input area of the program-mable controller min. 8 bytes in the output area of the program-mable controller max. 32 bytes in the input area of the programmable controller max. 32 bytes in the output area of the program-mable controller • • • 50 mm 80 mm 120 mm (without cable) DIL 1 .. 7 for setting the slave address DIL 10 as reset switch DIL 11 for switching from LOAD to RUN © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC PCS 807 Profibus-DP Multibox or PCS 590p/595p connected to Siemens PLC with I/O communication © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-1 B B-2 Siemens PLC © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC B.1 Determining the configuration For a Profibus-DP network setup are required by Siemens following products: • a S5-SPS or S7-300 (400) with Profibus-DP master • a Profibus-DP master plug-in module (only for S5), version IM308b (version 6), IM308c (version 2) or CP5431 • Programming software for the programmable controller and the master board • Profibus-DP network cable and bus connector ... as well as the power supply for all components. The settings of the components must match to enable all parts to correctly work together! IM308 master board Search for the right slot for your board. Otherwise, it may be damaged. The possible outlets are hatched gray. Slots in the S5-115U system Slots in the S5-135U and S5-155U system © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-3 B Siemens PLC Master board (S7 Profibus master) You determine the Profibus-DP network by configuring the master board (S7 Profibus master). The following limits are valid for a slave: B.1.1 • maximum number of bytes • minimal number of bytes • optimal number of bytes = 32 for I/O buffer = 8 for I/O buffer = buffer size of 12 inputs and 24 outputs for PCS micro/mini = buffer size of 24 inputs and 32 outputs for PCS midi and maxi Configuration of the master board (S5) You define the settings of the Profibus-DP network in the COM ET200 software. Also, each slave must be defined with its data length. IM308b (version 6) To be able to define the PCS 807 Multibox Profibus DP slave, you have to copy the „PCS002TD.200“ file from the PCS91.PDP diskette (please note the README.TXT file) into the COM ET200 directory. Pay attention, that under DOS the last drive statement is set to „LASTDRIVE=Z“ before executing the software. IM308c (version 2 or higher) Copy the „LAUERDPX.200“ type data into the „‘Typdat5x“ sub-directory. CP5431 In the DP editor, set the slave interval time manually. Call up now the COM ET200 software for an IM308b (version 6)... ET200 parameters • the baud rate should be between 187.5 and 1500 Kbaud. • the bus profile must be selected as „Standard Profibus-DP“. • the CPU type must be correctly selected. • a diagnosis is not required. Config parameters • here, you determine the slave parameters. • select the parameter file: „LauerDP slave 50“ for IM308b, • set the consistency to „0“. • define 8 ... 32 input bytes and 8 ... 32 output bytes per slave. Call up the COMWIN10 software for an IM308c... Bus parameters Select Profibus-DP B-4 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC Host parameters Select the used CPU Master parameters • station type: IM308c • addressing type: select the linear range for the P or Q page frame. P or Q tiles are possible in the page frame. Then, select the number of the IM308c (0/16/32/48). Each IM308c manages up to 16 tiles. • error message mode: Can be set to QVZ (acknowledgment delay on error). • set the response monitoring to: ON Slave parameters: • select the „LAUER_PCS_LCA“ type file. • you can SELECT P000-P255 and Q000-Q255 in the linear range. • OP192-15P255 is possible in the P page frame. • 0Q0-15Q254 is possible in the Q page frame. • specify the input bytes between 8 and 32and the output bytes between 8 and 32. • sync or Freeze are not necessary. • activate Module Consistency. Transfer Now, program the EPROM cassette or the Flash module and plug this into your IM308 board. Note the slave settings for the programmable controller programming. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-5 B Siemens PLC Call SINEC.NCM for a CP5431 (version 4.6). In contrast to the IM308 board, the CP5431 sends no configuration telegram. Thus, the setting on the boards and in the PCS 807 must agree. I/O byte DIL 5 DIL 6 8/8 16/16 OFF OFF 24/24 ON OFF 32/32 OFF ON ON ON The settings of DIL-switches 8 and 9 are taken over after a power up or reset. For a PCS 590p/595p, DIL-switches 5 and 6 are used for the configuration selection: I/O byte DIL 5 DIL 6 8/8 16/16 OFF OFF 24/24 ON OFF 32/32 OFF ON ON ON The CP5431 works only together with the SPC3 chip. Therefore use the PX807 1000. The Profibus-DP function may only be combined with asynchronous FMS services! Use only the I/O area of bytes 0...127 in the 115U CPU 941943 programmable controllers. Otherwise, inconsistencies can appear. Please note, that not all RAM modules are permissible for the CP5431 board! Please note following settings: CP INIT: Network file: NETZ2NCM.NET Network parameters: Default SAP: 61 Peripheral/ I/Oarea: DP Update: Cycle synchronous Input and output areas: enter ZI/DP start (even) and ZI/DP end (odd). Peripheral/ DP slave parameterizing: Maker ident: 0008 Sync mode: OFF Freeze mode: OFF B-6 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC Peripheral / DP editor: Global data: Largest min. slave interval: 2 x 1ms Min. poll cycle time: 1 x 10ms response monitoring time: 20 x 10ms Discontinue the user interface accordingly. Perform a network balance using the „NETZ2NCM.NET“ file and transfer database file into the CP5431. B.1.2 Configuration of the L2-DP network (S7) Sinec L2-DP network A Sinec L2-DP network is composed of a DP master and DP slave which are connected by a bus cable. They communicate with each other using the DP (decentralized peripheral) protocol. DP master As DP master you can use: • a CPU with firmly integrated or pluggable DP master interface (firmly integrated into e.g. CPU 315-2 DP) • a interface module that is assign to a CPU/FM (e. g. IF 964-DP in CPU 488-4) • a CP together with a CPU (e. g. CP 342-5: this is parameterized using a special software in called up STEP 7). DP slaves As DP slaves you can use: • modules with integrated digital/analog I/O channels (compact DP slaves, e. g. ET 200B, PCSS 807 or LCA 3xx.3) • interface modules with associated S5 or S7 modules (modular DP slaves, e. g. ET 200M). © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-7 B Siemens PLC Procedure Basically, you configure a SINEC L2-DP network using the Step7 software (hardware configuration) just with a local setup. Go ahead as follows: Conversion into a configuration table Allocate the DP master locally to a module rack. Allocate the DP slaves to an own configuration table. The change to this configuration table is only made after you have configured the DP master. B.1.3 Defining a master system • Requirement You have called up the configuration table. • Master system All DP slaves associated to a DP master and the DP master form a master system. A master system is part of a SINEC L2-DP network. • Master system definition After you have allocated the DP master in the configuration table, you define the pertinent master system. A master system means that you associate the DP master a SINEC L2-DP network and assign an L2 address to the DP master. • Select and allocate a DP master You select a DP master from the module catalogue and position it in the configuration table. Result: if the DP master is an integrated interface of a CPU then a „+“ is indicated to the left of the CPU. A second line appears with the DP master if you click onto the + sign. B-8 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC Further procedure: If you have allocated the DP master in the configuration table then you can either: • continue to allocate the „local“ modules in the configuration table or • configure the SINEC L2-DP network further by associating the DP master a SINEC L2-DP network and assign it an L2 address. • L2 address For the unambiguous identification, you must assign an L2 address to each DP master and DP slave of a master system in the SINEC L2-DP network. • Network and L2 address assignment Go ahead as follows to assign the network and L2 address: 1 mark the line in which the DP master is found. select the Edit -> Master system -> Open menu command. The dialog field for the network and L2 address assignment is displayed. 2 assign the DP master a SINEC L2-DP network (a default network is offered). 3 assign an L2 address to the DP master (the lowest free L2 address is offered as default value). Result: the „Master system configuration table“ is displayed after the assignment of the SINEC L2-DP network and L2 address. Master system configuration table In the master system configuration table, you allocate and parameterize all DP slaves of a master system. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-9 B Siemens PLC Select and allocate a DP slave Go ahead as follows to allocate a DP slave in the configuration table: 1 You must create the type file: From the PCSS 91.PDP diskette copy the LAUSPC3X.200 file into your STEP7\S7DATA\TYPE FILE directory. Open your configuration table. Select the Extras Update type files menu command on. Now, close your application and restart the STEP 7 software. The type file has now been entered in your hardware catalog. 2 Select the PCS_LCA with SPC3 DP slave from the hardware catalog (to be found under ProfibusDP\Normslave\Siemens). 3 Allocate the DP slave in the configuration table. STEP 7 offers you automatically the free L2 addresses in a list box. The next free L2 address is offered as default value. 4 Assign the L2 address. Allocate modular DP slave modules Go ahead just as if you allocate modules in a local setup to allocate modules to a modular DP slave. Please note that the DP slave must be opened before you can associate modules (click onto „+“). Now, insert 2 standard modules. Assign a designation to a modular DP slave Designations are assigned to modular DP slaves. the characteristics of the modules, e. g. addressing range and consistency of the data are encoded in the DP designation. The DP designation is automatically displayed if you insert the module in the configuration table. You can edit the DP designation by double-clicking onto the line of the DP designation. B-10 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC Assigning of I/O addresses Each input/output of a DP slave is assigned to exactly one address that is used for addressing. Therefore, you must assigned a starting address to each module/DP designation of a DP slave. STEP 7 automatically presents default addresses when you insert the module/the DP slave in the configuration table. The default addresses and their lengths are entered in „I addr.“ and „O addr.“ and „length columns. Enter the number of the input and output bytes for each slave. You can select between 8 and 32 bytes. Note the I/O address for the programmable controller programming! B.1.4 Programming of the programmable controller In the following, „FC“ is valid instead of „FB“ for an S7 application. You find the „README.TXT“ in the root directory of the PCS91.PDP floppy disk. The relevant handling block for each project is described in this file. Load the handling block for the Profibus-DP project into the programmable controller for a first test of the connection. With a Siemens S7, load the ‘’PCSS7L2.AWL“ file as S0 object (source) and compile it. (In case you are using a S7 300 then OB 101 should be deleted after compilation since it can only be used with the S7 400). Edit FB 201 and FB 202 (S7: FC 101 and FC 102). Adjust the assignment to the one of the PCS. Remove the stop commands! The PCS data block must be present in the start OB. Please note that the MB 236 ... 255 are used as temporary flags. For each PCS 807 Multibox Profibus DP slave, include a call of the handling block FB 203 („PROFIB-PS5D“ for the P page frame, „PROFIBQ.S5D“ for the Q page frame or PCSS7l2.AWL for the I/O area of an S7) in your programmable controller program. In case you are using the Ppage frame or the Q-page frame, you must set these before calling the FB 203. In the calling parameters, you define: UBDB the name of the data block, e.g. DB50 RXFA the location of the I-buffer (same as master board), e.g. KF +40 (S7: input location) RXLE the length of the I-buffer (same as master board), e.g. KF + 16 TXFA the location of the O-buffer (same as master board), e.g. KF +50 (S7: output location) TXFE the length of the O-buffer (same as master board), e.g. KF + 16 RSET the restart input, e.g. E0.0 TIMES the designation of the time-out timer, e.g. T5 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-11 B Siemens PLC TIMZ the time-out time, e.g. KT 20.1 = 2 seconds RFLM the first start flag, e.g. M10.0 EROR the error flag, e.g. A0.0 COFF the error block, e.g. FB 202 (S7: FC 102) INIT the first initializing block, e.g. FB 201 (S7: FC 101) Thus, the example is set to the following values: • The I-buffer is located from PW40 to PW54 and/or QW40 to QW54. • The O-buffer is located from PW50 to PW64 and/or QW50 to QW64. • Timer is the time-out timer T5 with a value of 2 seconds. • E0.0 is the restart input • A0.0 is the error output • FB 201 is selected in the first cycle. • FB 202 is called only once at a communication loss. B.1.5 Settings of the slave Multibox The PCS 807 Multibox Profibus DP slave automatically adapts to the alleged configuration. Only the slave number of the PCS 807 Multibox Profibus DP must be set. You set the slave number of the PCS 807 Multibox Profibus DP using the DIL-switches 1 to 7 to a number between 3 and 126. The setting must be made with the power being removed or in a reset condition (the setting is taken over at the start). The slave address is calculated as follows (OFF=0 and ON= 1): Slave-Nr DIL 1 DIL 2 DIL 3 DIL 4 DIL 5 DIL 6 DIL 7 DIL1 x 64 + DIL2 x 32 + DIL3 x 16 + DIL4 x 8 + DIL5 x 4 + DIL6 x 2 + DIL7 x 1 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 5 OFF OFF OFF OFF ON OFF ON 6 OFF OFF OFF OFF ON ON OFF 7 OFF OFF OFF OFF ON ON ON 125 ON ON ON ON ON OFF ON 126 ON ON ON ON ON ON OFF ... B-12 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC For the PCS 590p/595p operating console, the slave number is set in the driver using the PCSPRO configuration software. Start-up the components in two steps Step 1: Network • Set up the Profibus-DP network. • Supply power to the programmable controller and to the PCS 807 Multibox Profibus DP. • The IM 308 „RN“ LED is activated and the „BF“ LED of the flashes. • After about 5 seconds, the „BF“ LED of the master board is deactivated and the green „COM“ LED of the PCS 807 Multibox Profibus DP or the PCS 590p/595p is statically ON. • With the S7, the „SF-DP“ and the „BUSF“ LEDs are deactivated. Step 2: Logical communication B.1.6 • Now, you can connect the PCS (COM interface) to the PCS 807 Multibox Profibus DP (not the PCS 590p/595p). • Set the restart input of the programmable controller to „ON“ or switch the programmable controller from STOP to RUN. • The „COM“ LED of the PCS is deactivated after a maximum time of 2 seconds. S5 demo project A demo project for an IM308c is included on the Siemens floppy disk to enable a simple introduction into the Profibus-DP configuration. There, a Profibus-DP network with a PCS operating console in the linear P page frame area occupying bytes 0...15 is available. The procedure for commissioning is documented in detail in the enclosed README.DOC © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-13 B Siemens PLC file. B.1.7 Trouble-shooting Programmable controller enters STOP mode • The Stop commands in the handling software were not yet eliminated. Please eliminate these. • Programmable controller STOP on Profibus-DP error set in master configuration. Get network up and running. • Configuration of the master board is not compatible to the programmable controller. Please correct. IM308 does not enter the RUN mode or flashes (S7: master) • Wrong slot for IM308. Please correct. • Configuration data are wrong, not programmed or EPROM or Flash module is missing. Examine your data and the cassette. Programmable controller in RUN mode, IM308 „BF“ LED (S7: „BUSF“ LED) flashes longer than 10 seconds • error in the network configuration. Please eliminate. • PCS 807 Multibox Profibus DP not ready, because: • incorrectly connected. Please correct. • in the Load condition (DIL-switch 11 = OFF). first DIL 10 = ON, next DIL1 1 = ON, then DIL10 = OFF. • in reset condition (DIL-switch 10 = ON). Set DIL10 to OFF. • not powered up. Supply PCS 807 Multibox Profibus DP with 24V + 10% voltage. • wrong slave number. Set slave number correctly and trigger reset via DIL 10 (initiate reset with DIL 10 = ON, then DIL 10 = OFF) Programmable controller in RUN mode, IM308 „BF“ LED (S7: „BUSF“ LED) OFF, PCS „COM“ LED ON • PROFlBUS block is not called in the programmable controller. Please link. FB203 configuration does not match the master board. Time-out timer expired, set restart input to 0. (UEROR: =RSET) B-14 • PCS 807 Multibox Profibus DP DIL-switch 10 set to ON. Set PCS 807 Multibox Profibus DP DIL-switch to OFF. • A wrong driver was loaded into the PCS operating console. Load the right driver together with the data record once more into the PCS operating console. • IM308B start problems: the IM308B does not consider the slave © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC interval time during the start process. Thus, it can cause problems with the PX807 001. Switch master board from STOP to RUN. Programmable controller in RUN mode, IM308 „BF“ LED (S7: „BUSF“ LED) OFF, PCS „COM“ LED OFF, later ON again At first, communication is active (PCS „COM“ LED is deactivated) but after a certain time, the „COM“ LED starts to flash. This signals that the communication is basically functioning but a monitoring condition such as the time-out time was not observed. Possibly, the restart input is not set or the handling block is called irregularly. PCS 807 Multibox Profibus DP power LED (yellow) does not light B.1.8 • Power supply voltage 24 V + 10% must be observed. • Supply voltage reversed applied. Please correct. • Fuse in the unit is burned out. Send the unit in for repair. Term of the communication PCS 807 Multibox Profibus DP The PCS 807 Multibox Profibus DP software is based on the object codes of the Siemens company. In addition, serial communication and logical evaluation was added. Furthermore, the firmware is completely loadable. Loading state The PCS 807 Multibox Profibus DP is in the loading state if DIL 11 = OFF (yellow Run LED OFF), i. e. the EPROM is active and the EEPROM is externally addressable. Using a PC loader program, firmware can be now loaded into the unit using the serial interface. This is not necessary in the normal case since the unit is supplied with the firmware being loaded. Run state The PCS 807 Multibox Profibus DP is in the Run state if DIL 11 = OFF (yellow Run LED OFF) and the EEPROM program is active (the EPROM is switched off). To guarantee a defined initial start of the software, a reset must be triggered before the switching over DIL 10 to ON. This reset is then removed by switching DIL 10 to OFF again. During the start, the firmware reads the DIP switches 1-7 and takes over these values as slave address. The firmware now can be run as independent slave on the Profibus-DP network. The logical communication between PCS 807 Multibox Profibus DP and the programmable controller is started after plugging the serial interface into PCS 807 Multibox Profibus DP. Structure of the logical communication The Profibus-DP communication uses in Siemens the I/O area. Depending on the programmable controller, its size is between 128 bytes and several kilobytes (paging). A Profibus-DP master must be available in the programmable controller for communication. For this, Siemens supplies the IM308 board. The largest I/O unit that can be transferred is 32 bytes in size (thus, the largest configuration size of the PCS 807 Multibox Profibus DP is 32 bytes). The configuration of the PCS 807 Multibox Profibus DP slave is determined © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-15 B Siemens PLC with the IM308 master board (S7: Profibus master). The slave with the correct slave address automatically conforms to the configuration. This configuration will be submitted to the PCS operating consoles driver to setup the correct job/response packages. According to the configuration, the driver in the PCS operating console splits the occurring jobs into part jobs. One-by-one, every part job is submitted to the PCS 807 Multibox Profibus DP for the transfer. A job number is attached to each transmission. The job is stored in the input area of the programmable controller. A programmable controller expander program reads the job and executes it on a DB. The result is stored in the output area with the job number being inverted. From there, it is submitted to the PCS 807 Multibox Profibus DP. Then, it is serially transferred to the driver. The currently realized transfer times of PCS 807 Multibox Profibus DP to the programmable controller and vice versa are essentially limited by the SPC3 chip and the Siemens software to 50 msec min. Thus, a transfer „PCS 807 Multibox Profibus DP – programmable controller processing – PCS 807 Multibox Profibus DP“ lasts approx. 150ms. Including the serial transfer, the processing of a part job thus lasts approx. 180 msec. At an average of 6 jobs for a PCS 090, a communication cycle lasts approx. 500msec. Thus, the key LED time is 2 x communication cycle = 1 second. Visual monitoring yellow „Power On“ LED. It represents the functioning of the switching power supply. yellow „RUN“ LED. This LED is OFF in the loading state. It is ON in the Run state. green „Communication“ LED. This LED is OFF with communications being inactive. The LED flashes if a baud rate is recognized. The LED lights if a data exchange occurs. B-16 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B Siemens PLC With a PCS 590p/595p, a green „Communication“ LED is available on the rearside of the unit. A data exchange occurs if it is activated. In addition, the „COM“ LED on the PCS 590p/595p frontpanel is only deactivated if the handling software is correctly executed in the programmable controller. B.1.9 Optimal configuration The communication speed depends essentially on the following elements: Occurring tasks in the PCS The display content and the enabled transfers in the command words determine the tasks of the PCS operating console. Slave configuration An increased I/O buffer size in the programmable controller will also increase the processing speed of the jobs in the PCS. The output buffer should have twice the size of the input buffer. AJ driver variable This variable changes the refresh behavior of the variables and the keys. AJ = 1 --> Keys and LEDs will be quickly transferred, variables are refreshed slowly - suited for jog operation. The I/O buffer can be small. AJ = 10 --> Default values. Represent a balance between the key and the variable refresh. AJ = 20 --> Keys and LEDs will be transferred simultaneously with variables. This setting is suited for the display of many variables. The I/O buffer should be as large as possible. PCS 807 module version: In the PX807 0001 version, a SPC2 chip is integrated that requires a min. slave interval time of 50 msec. In the PX807 1000 version, a SPC3 chip is integrated that requires a min. slave interval time of 3 msec. The version with the SPC3 chip is effectively approx. 3 times faster than the SPC2 version. Configuration examples: ² PCS 900 • Slave configuration: 16 bytes I-buffer and 32 bytes O-buffer • AJ = 10 • The command words in the programmable controller are used as follows: W36 = KH0F60 W37 = KH0001 The transfer of the time and the date is disabled and a message © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 B-17 B Siemens PLC block is enabled for the transfer. Now, you will have an optimal communication for the key LED area of less than one second if you take provisions to display only a few variables. ² PCS 095 • Slave configuration: 12 bytes I-buffer and 24 bytes O-buffer • AJ = 10 • The command word in the programmable controller is used as follows: W13 = KH0FC 1 Thus, the messages M0 ... 15 are enabled for the transfer. Now, you will have an optimal communication for the key LED area of less than 0.8 seconds if you take provisions to display only a few variables. ² PCS 095 • Slave configuration: 8 bytes I-buffer and 16 bytes O-buffer • AJ = 1 • The command word in the programmable controller is used as follows: W13 = KH0FC 1 Thus, the messages M0 ... 15 are enabled for the transfer. Keys will be transferred quickly but the refreshing of the variable takes a longer time. The key LED time totals approx. 0.5 seconds. However, if you press a key only for a short time then the LEDs are read only when the key is released again. Thus, the LED will not light. ² PCS 9000 • Slave configuration: 24 input bytes and 32 output bytes • AJ = 10 • The command word in the programmable controller is used as follows: W13 = KH 000C (CLK_D bit on pos. 2) (CLK_C bit on pos. 3) W16 = KH 0 W17 = KH FF00 The transfer of the time and the date is disabled. Display no external variables in the status window as far as possible. ² PCSS 590p/595p • Slave configuration: 16 bytes I-buffer and 32 bytes O-buffer • AJ = 7 • The command word in the programmable controller is used as follows: W13=KH 0FC4 W27 = 0 Thus the messages M0 ... M63 are enabled for the transfer. Now, you will have a communication time of less approx. 0.8 seconds for the key LED area if you take provisions to display only a few variables. B-18 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC PCS 807 Profibus-DP Multibox or the PCS 590p/595p for Bosch PLC with I/O-communication © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-1 C C-2 Bosch PLC © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC C.1 Determining the configuration The following Bosch products are required for a Profibus-DP network setup: 1 Cl400 programmable controller 2 DESI-DP or DESI-DP12 Profibus master board 3 programming software for the programmable controller and the master board 4 Profibus-DP network cable and bus connector ... as well as power supplies for all components C.1.1 Configuration of the master board (DESI-DP) The corresponding settings must match to secure a correct interaction of all parts! Type file Copy the „LAUERDP.GSD“ file into your BOSCH.BIB directory. This file is required for the master file to be created and contains all configuration possibilities of the PCS 807 slaves. Call up now the Profi software of the master board. Select the DP software using F3. Create a new project or use the included PCS DP project. Use F2 to enter the editor. Select the PCS 807 in the BTN overview. Under the Modules group select the configuration fitting your application best (size of the transfer buffer in bytes). Specify the slave address for the PCS 807 module or the PCS 590p/595p. Now, switch to the BTN detail window using F5. Enter here the input and output bytes desired for the communication. You can use also the expanded inputs and outputs. Make sure that you specify an asending order since otherwise the handling block interprets the communication commands wrong. The Desi-DP master board requires coupling field with a size of 6 byte for the data exchange. Set the starting address of the coupling field in the „Bus master settings“ menu. Load the master file into the master board. Consider the set baud rate of the software and the set baud rate of the master board. Remark! Note the set sizes for inputs and outputs, their start addresses and all other settings. They are required for the handling block or for the DILswitch settings of the master board. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-3 C Bosch PLC Hardware settings using the DESI-DP board as an example (refer also to the Bosch DESI-DP Bus Master manual) Set the coupling address using DIL-switch S4: switch 1 of S4 is used to select the addressing range. ON I/O field OFF EZ/AZ field The other switches of S4 are used for the start address settings (refer to the following figure). Valence: I/O 21 22 23 24 25 26 27 Example: Coupling address: EZ/AZ· Used: 0.0 - 5.7 Example: Coupling address: I/O 4 Used: 4.0 - 9.7 Baud rate [Kbaud] 9.6 19.2 93.75 187.5 500 1500 1 OFF ON OFF ON OF F OFF switches 2 OFF OFF ON ON OFF ON 3 OFF OFF OFF OFF ON ON 4 OF F OFF OFF OFF OFF OFF Set the desired transfer rate using DIL-switch S5. Thereby, the PCS 807 slave module is adjusted automatically. All DIL-switches of S3 were set to OFF in the test setup. Remark! With other boards used, possibly other settings are required for the master station address (refer to DESI-DP12 ). Please inform yourself using the corresponding manuals of the master board. C-4 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC For the evaluation of the received data, the „PCS_KOMM“ block is required that takes over the data traffic with the PCS DBs. Furthermore, an initialization (INIT)and an error block (COFF)is made available. You can use these blocks to define data word pre-assignments or emergency assignments. In addition, an example OB 1 is provided in which the block call is implemented. You find the files on the PCS 91.PDP floppy disk in the Profibus directory. Remark! In OB1, the first input word of the master coupling field must be copied to the first output word of the coupling field. This is required for the synchronization of CPU-DP master. Parameters of the PCS_KOMM block: The block requires 14 parameters. This makes it possible to freely select the addresses. An example is provided in OB 1 (refer to the printout of the handling block). The meaning of the parameters is as follows: P0: PCS user DB. (PCS data 256 words ) P1: Start address of your selected Profibus input bytes P2: Length of the selected Profibus input field minus 1 byte P3: Start address of your selected Profibus output bytes P4: Length of the selected Profibus output field minus 1 byte P5: Restart input or flag. This is required to restart the communication after a communications fault. (Set the input to permanently high for an automatic reset) P6: Timer for time-out monitoring P7: timer time as constant P8: Communication error output (the output is set to high level after a communications fault) P9: PB of the „INIT“ block P10: PB of the „COFF“ block P11: Required flag (freely selectable, may not be used by other program parts) P12: Required flag (freely selectable, may not be used by other program parts) P13: Required flag (freely selectable, may not be used by other program parts) © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-5 C Bosch PLC C.1.2 Trouble-shooting Programmable controller enters STOP mode • The Stop commands in the handling software were not yet eliminated. Please eliminate these. • Configuration of the master board is not compatible to the programmable controller. Please correct. Programmable controller in RUN mode, „Send“ LED“ is OFF • Errors in the network configuration • Multibox not ready due to: Wrong slave address. Check whether the master file matches the address. In reset condition (DIL-switch 10 is set to ON). Set DIL 10 to OFF. No supply voltage. Apply voltage to the Multibox. Programmable controller in RUN mode, „Send“ LED is ON, status message 01 • Programmable controller in Stop mode. Switch the programmable controller to RUN • Network fault. Check whether all participants are configured correctly. Check the cabling. • Coupling fault (CPU is not synchronized with master board ). Check whether the start input word of the selected coupling field is cyclically copied to the start output word. Programmable controller in RUN mode, „Send“ LED is ON, no status message, PCS „Com“ LED is ON • Lauer handling block is not called in the programmable controller program. Please link in with correct parameters. • A wrong driver was loaded into the PCS. Transfer the data record together with the correct driver again into the PCS operating console. Programmable controller in RUN mode, „Send“ LED is ON, no status message, PCS „Com“ LED is OFF but later ON again C-6 • The network configuration was not synchronized with all participants. Power down all involved units. Restart all units. • The network setup is located in noisy environment. Provide for corresponding interference suppression. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC Configuration examples: ² PCS 900 • Slave configuration: 16 bytes I-buffer and 32 bytes O-buffer • AJ = 10 • The command words in the programmable controller are used as follows: W36 = KH0F60 W37 = KH0001 The transfer of the time and the date is disabled and a message block is enabled for the transfer. Now, you will have an optimal communication for the key LED area of less than one second if you take provisions to display only a few variables. ² PCS 095 • Slave configuration: 12 bytes I-buffer and 24 bytes O-buffer • AJ = 10 • The command word in the programmable controller is used as follows: W13 = KH0FC 1 Thus, the messages M0 ... 31 are enabled for the transfer. Now, you will have an optimal communication for the key LED area of less than 0.8 seconds if you take provisions to display only a few variables. ² PCS 095 • Slave configuration: 8 bytes I-buffer and 16 bytes O-buffer • AJ = 1 • The command word in the programmable controller is used as follows: W13 = KH0FC 1 Thus, the messages M0 ... 31 are enabled for the transfer. Keys will be transferred quickly but the refreshing of the variable takes a longer time. The key LED time totals approx. 0.5 seconds. However, if you press a key only for a short time then the LEDs are read only when the key is released again. Thus, the LED will not light. ² PCS 9000 • Slave configuration: 24 input bytes and 32 output bytes • AJ = 10 • The command word in the programmable controller is used as follows: W13 = KH 000C (CLK_D bit on pos. 2) (CLK_C bit on pos. 3) W16 = KH 0 W17 = KH FF00 The transfer of the time and the date is disabled. Display no external variables in the status window as far as possible. © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-7 C Bosch PLC ² PCSS 590p/595p • Slave configuration: 16 bytes I-buffer and 32 bytes O-buffer • AJ = 7 • The command word in the programmable controller is used as follows: W13=KH 0FC4 W27 = 0 Thus the messages M0 ... M63 are enabled for the transfer. Now, you will have a communication time of less approx. 0.8 seconds for the key LED area if you take provisions to display only a few variables. C-8 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC C.2 Print out handling software OB1 PB0 PB2 PB3 OB1 PCS_KOMM INIT COFF Master Baustein Expanderprogramm für PCS Initialisierungsbaustein Fehlerbaustein ; OB1 ; Filename: ; function: 1 2 OB1 Organisationsbaustein ; p r o g r a m ;*********************************************************************** L W EZ64,A ; copy the first word of your I/O-Area of the T W A,AZ64 ; CPU - DESI-DP communication from input to ; output ; call the Lauer communication subroutine PB (PCS_KOMM) 3 4 BA P0 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 W W W W W B W W B W W B B B -PCS_KOMM,14 -DB1 &EZ10 K31D &AZ10 K31D -RESTART -TIMER K4.2 M100.0 -INIT -COFF M100.2 M100.3 M100.4 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; call expander program DB PCS-datafield of 256 words W startaddress of the Profibus-Input K lenght of input-bytes - 1 W startaddress of the Profibus-Output K lenght of output-bytes - 1 B restart input T watch dog PCS-communication K timevalue for watch dog B output-bit communication error PB INIT (communication init PCS) PB COFF (communication error PCS) B for internal use B for internal use B for internal use ;U ;= B B M100.0 A3.7 ; communication error to output PE ;program end ; PCSKOMM ; expander-program for communication via Profibus with PCS-Topline PCS_KOMM ; function: expander for the CL400 ; D e c l a r a t i o n ; subroutine parameter: ;~~~~~~~~~~~~~~~~~~~~~~~~~~ ;BA -PCS_KOMM,14 ; call expander program ;P0 W -DB1 ; DB PCS-datafield of 256 words ;P1 W &EZ10 ; W startaddress of the Profibus-Input ;P2 W K31D ; K lenght of input-bytes - 1 ;P3 W &AZ10 ; W startaddress of the Profibus-Output ;P4 W K31D ; K lenght of output-bytes - 1 ;P5 B -RESTART ; B restart input ;P6 W -TIMER ; T watch dog PCS-communication ;P7 W K4.2 ; K timevalue for watch dog ;P8 B M100.0 ; B output-bit communication error ;P9 W -INIT ; PB INIT (communication init PCS) ;P10 W -COFF ; PB COFF (communication error PCS) ;P11 B M100.2 ; B for internal use ;P12 B M100.3 ; B for internal use ;P13 B M100.4 ; B for internal use ; ; Filename: p r o g r a m ;************************************************************************** ; © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-9 C Bosch PLC ; processor reset ⇒ reset BT9_KOM ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ PZ: 1 1 U B -P_RI 2 O B -NEU_RI 3 SPB -START_KO ; → 4 BX -P0 PZ: 2 5 U B -P12 ;second cycle to catch whole data (inputs) 6 SPB -WAITDAT1 PZ: 3 7 U B -P13 8 SPB -WAITDAT2 ;second cycle to catch whole data (outputs) ; no process if timeout and restart input = 0 ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ PZ: 4 9 UN B -P5 ; timeout ? 10 U B -P8 ; restart ? 11 BEB ; instruction-number = 0 => wait for instruction-number = 0 ; ; if instruction-number = n => process received data ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 12 XO W B,B ; A Register = 0 13 L W -P1,A ; instruction-number = 0 ? Input 14 L BY [A],A 15 VGL BY A,B 16 SPZ -NO_AUFTR ; → 17 BX -P0 ; open PCS-DB ; instructions-number > 0 ⇒ process the instructions ; ; Have the whole instruction received ? 18 19 20 21 22 23 24 25 26 27 28 L L L VGL SPZ L L ADD L VGL SPN BY W BY BY DX3,B -P1,A [A],A A,B -NO_AUFTR W -P1,A BY [A],B W -P2,A BY [A],A BY A,B -NO_AUFTR 29 30 31 PZ: UN = BE 5 B B 32 33 34 35 36 37 38 39 PZ: U = L ADD L ADD L T -P11 -P12 -WAITDAT1 6 B -P11 B -P12 W -P1,A W K1H,A W -P3,B W K1H,B W K2H,D BY D,DX2 ; old instruction-number in byte 3 ; load instruction-number (input) ; ; ; ; ; ; ; ; ; compare old with new if even → no new instructions load address of receive inputs load instruction-number 1. byte load instruction-number last byte compare first with last if not even → instructions are not complete ;set wait-flag and wait one cycle ;reset the wait-flag ; indir.address of datainputs ; at byte 2 load first instruction ; indir.address of dataoutputs ; reset receive counter ; DX2 = receive-counter ; analyse of the instructions C-10 -read_new ; ← BY [A],C W A,A -AUFT_END 40 41 L L ;SP 42 PUSH W ; read actual instruction C © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC 43 44 45 46 47 48 49 50 51 52 53 54 55 56 ADD L T U VGL SPZ VGL SPZ VGL SPZ VGL SPZ POP SP 57 58 ;========================================================================== ; read instruction: copy data from PCS-datafield to send outputs ;========================================================================= -READ ; ← POP W C PUSH W A ; pointer receive inputs to stack 59 60 61 62 63 64 L U SLL O L U BY W W W BY BY 65 66 67 68 69 70 71 72 73 74 75 76 77 VGL SPZ INC L T DEC INC L T INC INC DEC SP -return_r ; ← BY K0H,C -r_end W A,1 BY [A],D BY D,[B] W A,1 W B,1 BY [A],D BY D,[B] W B,1 W A,2 BY C,1 -return_r ; → 78 79 80 81 82 83 84 85 86 87 88 89 W BY BY BY BY K1,A [A],C C,D KF0H,C K10H,C -READ BY K20H,C -WRITE BY K40H,C -WRITE_U BY K80H,C -WRITE_O W C -AUFT_END ; read instruction ; → ; write instruction ; → ; write and „AND“ instruction ; → ; write and „OR“ instruction ; → C,A K00FFH,A A,1 K1800H,A D,C K0FH,C ; load dataword address ; * 2 ; at to indirect address PCS-Datafield ; load instruction ; mask count of datawords copy until count of datawords = 0 ; read instruction end ; load high byte from PCS-datafield ; write to send outputs ; ; ; ; ; ; increment send pointer load low byte from PCS-datafield write to send-outputs increment send pointer increment datafield-address decrement dataword counter ; is there another instruction ? ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -r_end POP W A ; load from stack receive pointer L BY DX2,D ; U W K00FFH,D ADD W K2H,D ; increment receive pointer VGL W -P2,D ; check if receive end SPP -AUFT_END T BY D,DX2 INC W A,1 ; next instruction address L BY [A],D ; VGL BY K0H,D ; check if instruction = 0 SPZ -AUFT_END SP -read_new ; → ; there is another instruction ; → process the next instruction ; end read instruction ;========================================================================== ; write instruction: copy datawords from receive inputs to PCS-datafield ;========================================================================== -WRITE ; ← © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-11 C Bosch PLC 90 91 POP W PUSH W C B 92 93 94 95 96 97 98 99 L U SLL O L U PUSH INC W W W W BY BY W W C,B K00FFH,B B,1 K1800H,B D,C K0FH,C C A,1 100 101 102 103 104 105 106 107 108 109 110 111 112 VGL SPZ INC L T DEC INC L T INC INC DEC SP -return_w ; ← BY K0H,C -w_end W B,1 BY [A],D BY D,[B] W B,1 W A,1 BY [A],D BY D,[B] W A,1 W B,2 BY C,1 -return_w ; ← 113 114 115 116 117 118 119 120 121 122 123 124 125 126 ; send pointer to the stack ; load PCS-dataword-address ; * 2 ; ; ; ; ; add to indirect address PCS-datafield load instruction mask count of datawords dataword counter to the stack increment receive pointer ; copy until dataword counter = 0 ; ; ; ; ; ; ; ; ; ; ; write instruction end receive address of high byte load byte from receive inputs and store it as high byte receive address of low byte increment datafield address load byte from receive inputs and store it as low byte increment datafield address increment receive pointer decrement dataword counter ; is there another instruction ? ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -w_end POP W C ; load from stack dataword counter POP W B ; load from stack send pointer INC W C,1 ; count +1 instruction word SLL W C,1 ; count of byte L BY DX2,D U W K00FFH,D INC W D,[C] ; increment receive pointer VGL W -P2,D ; check if receive end SPP -AUFT_END T BY D,DX2 L BY [A],D ; load next instruction VGL BY K0H,D ; check if instruction = 0 SPZ -AUFT_END ; → SP -read_new ; → ; there is another instruction ; → process the next instruction ; end write instruction ; write and „AND“ instruction: that is an „AND“ function between received ; data and the data in the datafield, stored ; later in the datafield ;========================================================================== 127 128 -WRITE_U POP W C PUSH W B 129 130 131 132 133 134 135 136 L U SLL O L U PUSH INC W W W W BY BY W W C,B K00FFH,B B,1 K1800H,B D,C K0FH,C C A,1 -return_u C-12 ; send pointer to the stack ; load PCS-dataword-address ; ; ; ; ; ; ; ← * 2 add to indirect address PCS-datafield load instruction mask count of datawords dataword counter to the stack increment receive pointer ; copy until dataword = 0 © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 Bosch PLC VGL SPZ INC L U T DEC INC L U T INC INC DEC SP BY K0H,C -u_end W B,1 BY [A],D BY [B],D BY D,[B] W B,1 W A,1 BY [A],D BY [B],D BY D,[B] W A,1 W B,2 BY C,1 -return_u ; → ; ; ; ; ; ; ; ; ; ; ; ; ; write „AND“ instruction end receive address of high byte load high byte from receive inputs „AND“ byte from PCS-datafield store it as high byte receive address of low byte increment datafield address load low byte from receive inputs „AND“ byte from PCS-datafield store it as low byte increment datafield address increment receive pointer decrement dataword counter ; is there another instruction ? ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -u_end POP W C ; load from stack dataword counter POP W B ; load from stack send pointer INC W C,1 ; count +1 instruction word SLL W C,1 ; count of byte L BY DX2,D U W K00FFH,D INC W D,[C] ; increment receive pointer VGL W -P2,D ; check if receive end SPP -AUFT_END T BY D,DX2 L BY [A],D ; load next instruction VGL BY K0H,D ; check if instruction = 0 SPZ -AUFT_END ; → SP -read_new ; → ; there is another instruction ; → process the next instruction ; end write „AND“ instruction ; write and „OR“ instruction: that is an „OR“ function between received ; data and the data in the datafield, stored ; later in the datafield 166 167 -WRITE_O POP W C PUSH W B 168 169 170 171 172 173 174 175 L U SLL O L U PUSH INC W W W W BY BY W W 176 177 178 179 180 181 182 183 184 185 186 VGL SPZ INC L O T DEC INC L O T -return_o BY K0H,C -o_end W B,1 BY [A],D BY [B],D BY D,[B] W B,1 W A,1 BY [A],D BY [B],D BY D,[B] ; ← ; send pointer to the stack C,B K00FFH,B B,1 K1800H,B D,C K0FH,C C A,1 ; load PCS-dataword-address ; ; ; ; ; ; ; ← * 2 add to indirect address PCS-datafield load instruction mask count of datawords dataword counter to the stack increment receive pointer ; copy until dataword counter = 0 ; ; ; ; ; ; ; ; ; ; write „OR“ instruction end receive address of high byte load byte from receive inputs „OR“ byte from PCS-datafield and store it as high byte receive address of low byte increment datafield-address load byte from receive inputs „OR“ byte from PCS-datafield and store it as low byte © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-13 C 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 Bosch PLC INC INC DEC SP W A,1 W B,2 BY C,1 -return_o ; → ; increment datafield-address ; increment receive pointer ; decrement dataword counter ; is there another instruction ? ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -o_end POP W C ; load from stack dataword counter POP W B ; load from stack send pointer INC W C,1 ; count +1 instruction word SLL W C,1 ; count of byte L BY DX2,D U W K00FFH,D INC W D,[C] ; increment receive pointer VGL W -P2,D ; check if receive end SPP -AUFT_END T BY D,DX2 L BY [A],D ; load next instruction VGL BY K0H,D ; check if instruction = 0 SPZ -AUFT_END ; → ; SP -read_new ; → ; there is another instruction ; process the next instruction ; end write „OR“ instruction ; AUFT_END: all instructions are done ; ← 205 206 207 BE 208 209 ; Invert instruction-number and write it to the first and last byte ; of the communication outputs ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -WAITDAT2 PZ: 8 U B -P11 ; reset wait-flag = B -P13 210 211 212 213 214 215 216 217 L L T XO L T ADD T W BY BY BY W BY W BY ; wait one cycle to be sure that ; all outputs are refreshed -P1,A [A],D D,DX3 KFFH,D -P3,A D,[A] -P4,A D,[A] ; load instruction-number ; store it in byte 3 ; invert the instruction-number ; store it in the first and last ; output bytes 219 220 ; watch dog ;~~~~~~~~~~~ ; trigger time ;———————————————————— U W -P7,D PZ: 9 U B -LOG0 SE D,-P6 221 222 PZ: U R 223 BE 218 C-14 -AUFT_END 7 B -P11 B -P13 PZ: UN = 10 B -LOG1 B -P8 ; timevalue ; ; Watchdogmerker reset ; → © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C Bosch PLC ; end instructions ; no new instructions -NO_AUFTR 224 225 226 L PZ: U SE W -P7,D 11 B -LOG1 D,-P6 227 228 PZ: U BEI 12 B -P6 ; ← ; timevalue ; timeout ? ; set fault watch dog has responsed ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ -KOMM_FEL 229 230 231 232 233 S XO B W -P8 D,D ; watch dog ; init after communication error ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ BA -P0 ; open PCS-DB BA -P10 ; COFF BE ; → ; end watch dog ; start of communication 235 236 -START_KO ; start timer ;~~~~~~~~~~~~~~~~~~~~ L W -P7,D PZ: 13 U B -LOG0 SE D,-P6 237 238 ; reset fault ;~~~~~~~~~~~~~~~ PZ: 14 U B -LOG1 R B -P8 239 XO 240 241 ; init output at the first cycle ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ L W -P3,A T W D,[A] 234 W ; watch dog D,D ; init PCS-DB at first cycle ;~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ;BA P0 ;BA P9 242 ; timervalue ; open PCS-DB ; INIT BE ; → ; end start communication ;program end ;** INIT: Subroutine INIT inits the PCS-datafield at the first cycle ;** The user can program his own specifications ;HLT ;!!!!! Here you have to specify your init values ;********************************** !!! at least set your © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103 C-15 C Bosch PLC ;********************************** key-bytes to zero !!!!! ;***** Example PCS 009/090/095***** ;L W K0D,A ;T W A,D8 ;T W A,D10 ;T W A,D46 ;L W K0FC8H,A ;T W A,D26 ;CONTROLWORD A ;L W K0080H,A ;T W A,D28 ;CONTROLWORD B ;***** EXAMPLE PCS 900/920/950 ***** ;L W K0D,A ;T W A,D8 ;T W A,D10 ;T W A,D12 ;T W A,D18 ;T W A,D78 ;CONTROLWORD ;L W K0080H,A ;T W A,D76 ;CONTROLWORD ;L W K00FFH,A ;T W A,D74 ;CONTROLWORD ;L W K1F00H,A ;T W A,D72 ;CONTROLWORD 1 D C B A BE ;** COFF: subroutine COFF inits the PCS-datafield after communication error ;** ( emergancy case ) The user can program his own specifications ;HLT ;!!!!! Here you have to specify your emergancy values ;********************************** ;********************************** ;********************************** !!!!! CAUTION !!!!! ;********************************** at least set the Key-bytes to zero ;********************************** ;***** Example PCS 009/090/095 ***** ;L W K0D,A ;T W A,D8 ; keys ;T W A,D10 ; keys ;T W A,D46 ; keys ;***** Example PCS 900/920/950 ***** ;L W K0D,A ;T W A,D8 ;keys ;T W A,D10 ; ;T W A,D12 1 C-16 BE © Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2003:02:07 11:50:18+01:00 Modify Date : 2003:02:07 11:50:18+01:00 Subject : 91pdp00_e Page Count : 48 Creation Date : 2003:02:07 10:50:18Z Mod Date : 2003:02:07 10:50:18Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : ZOCH Keywords : Metadata Date : 2003:02:07 10:50:18Z Creator : ZOCH Title : 91pdp00_e Description : 91pdp00_e Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools