CONNECTIONS TO TERMINALS OF POWER SUPPLY:
PRI: Supply 117V+10% -10%
60Hz 30VA protect by
PTC SIEMENS C840.
Power dissipated by power supply: 8,5 W
1: Handset receiver
2: Handset microphone
3: Handset receiver and microphone common
3 (-): Intecommunication system power supply
6 (+): 9V c.c.
6: Common receiver and microphone for speech unit
7: Speech unit microphone
8: Speech unit loudspeaker
C1: Output for call generator with modulated sound for
push-buttons commun wire, to be used with “Sound System”
series interphones.
C2: Output for call generator with continuous sound for
push-buttons commun wire, to be used with “Sound
System” series interphones.
CP: 15V~ output for commun wire push-buttons to be used
with A.C. call interphones.
0: Output 15V
1A (on intermittent operation)
3 sec. ON, 180 sec. OFF, 0,4A continuous
15: protect by PTC SIEMENS C945
0: 3 sec. ON, 180 sec. OFF, 0,4A continuo
Output 15V rectified 1A (on intermittent operation)
3 sec. ON, 180 sec. OFF, 0,4A continuous
AS: protect by PTC SIEMENS C945
}
}
}
}
CSA product is according to UL 6500
POWER SUPPLY FOR ELECTRIC DOOR-OPENER SYSTEM WITH
BUILT-IN TWO-TONE ELECTRONIC SOUNDER AND FOR NOTICE OF
CALL IN DOOR ENTRY PANEL
WIRING INSTRUCTIONS
}
The circuits inside the power supply are further protected by a
SIEMENS PTC, type C965.
N.B. When using continuous duty 0-15 and 0-AS outputs, do
not connect loads of over 0.25A.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Description of symbols shown in the power supply.
double square: it is a class II power supply
triangle with ligthning: hazard of electric shock, dangerous vol-
tage;
Triangle with exclamation mark: danger, pay attention.
}
2
IMPORTANT SAFETY INSTRUCTIONS
1- Read these instructions
2- Keep these instructions
3- Heed all warnings
4- Follow all instructions
5- Do not use this apparatus near water
6- Clean only with dry cloth
7- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that product heat.
9- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit
from the apparatus.
11- Only use attachments/accessories specified by the manufacturer.
12- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been expo-
sed to rain or moisture, does not operate normally, or has been dropped.
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids,
such as vases, not be placed on this apparatus
CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform
any servicing other than that contained in the operating instructions unless you are qualified to do so.
13- Apparatus shall not be exposed to dripping or splashing and no objects with liquids, such a vases, shall be placed on the apparatus.
14- The set disconnection device from the mains is the plug.
TECHNICAL CHARACTERISTICS OF POWER SUPPLY ART. 931A/C17
Power supply in grey ABS housing; preset for mounting on cases with DIN 8-module support.
This power supply features a dual electronic tone generator which replaces the traditional alternating current call on a buzzer or bell. The
sound signal has two different tones (on terminals C1-C2), enabling users to immediately identify which point is calling (main entrance, gate,
garage, etc.). This solution also makes it possible to use a single loudspeaker built into the phone itself to produce the sound. The use of C1
terminal for push-buttons commun wire for calls coming from the panel enables the activation of an acoustic signal in the same panel when
calls are made to the interphones.
Furthermore, this power supplier has been preset for operation with interphones with A.C. call; for such purpose terminal “CP” must be used
as push-buttons “commun” terminal for calls from the door entry panel, which also routes an acoustic sound to the panel.
OPERATING INSTRUCTIONS
This power supply can be used for two types of systems:
1) Simple communication between the inside phones and outdoor unit (Art. 930). Diagram c3693, c3694.
2) Communication between the speech unit (Art. 930) and inside phones with conversation privacy between users. In this case only the
phone called from the outdoor unit is enabled for conversation and release of the lock, if any, on the door. Diagram c3762, c3763.
SAFETY INSTRUCTIONS FOR INSTALLERS
- Carefully read the instructions on this leaflet: they give important information on the safety, use and maintenance of the installation.
- After removing the packing, check the integrity of the set. Packing components (plastic bags, expanded polystyrene etc.) are dangerous
for children. Installation must be carried out according to national safety regulations.
- It is convenient to fit close to the supply voltage source a proper bipolar type switch with 3 mm separation (minimum) between contacts.
- Before connecting the set, ensure that the data on the label correspond to those of the mains.
- Use this set only for the purposes designed, i.e.for electric door-opener systems. Any other use may be dangerous. The manufacturer is
not responsible for damage caused by improper, erroneous or irrational use.
- Before cleaning or maintenance, disconnect the set.
- In case of failure or faulty operation, disconnect the set and do not open it.
- For repairs apply only to the technical assistance centre authorized by the manufacturer.
- Safety may be compromised if these instructions are disregarded.
- Do not obstruct opening of ventilation or heat exit slots and do not expose the set to dripping or sprinkling of water.
- Installers must ensure that manuals with the above instructions are left on connected units after installation, for users' information.
- All items must only be used for the purposes designed.
- The ominipolar switch must be easily accessed.
-WARNING: to avoid the possibility of hurting yourself, this unit must be fixed to the wall according to the installation instructions.
- This leaflet must always be enclosed with the equipment.
Directive 2002/96/EC (WEEE)
The crossed-out wheelie bin symbol marked on the product indicates that at the end of its useful life, the product must be handled
separately from household refuse and must therefore be assigned to a differentiated collection centre for electrical and electronic
equipment or returned to the dealer upon purchase of a new, equivalent item of equipment.
The user is responsible for assigning the equipment, at the end of its life, to the appropriate collection facilities.
Suitable differentiated collection, for the purpose of subsequent recycling of decommissioned equipment and environmentally compatible
treatment and disposal, helps prevent potential negative effects on health and the environment and promotes the recycling of the materials
of which the product is made. For further details regarding the collection systems available, contact your local waste disposal service or the
shop from which the equipment was purchased.
Risks connected to substances considered as dangerous (WEEE).
According to the WEEE Directive, substances since long usually used on electric and electronic appliances are considered dangerous for
people and the environment. The adequate differentiated collection for the subsequent dispatch of the appliance for the recycling, treat-
ment and dismantling (compatible with the environment) help to avoid possible negative effects on the environment and health and pro-
mote the recycling of material with which the product is compound.
3
AU
6PA
6S
C
5
6
6E
2
3
1
7
ELVOX
A
PRI
27C23-1 C18
B
L1
321S
6 15 ASO
7
8
4/5
3
1
2
6
7
6
5
8
3
4
D
C
CP
CH
WIRING DIAGRAM OF ELECTRIC DOOR OPENER WITH "SOUND SYSTEM" CALL, CON-
VERSATION PRIVACY, DIRECT LOCK RELEASE NOTICE AND CALL IN DOOR ENTRY
PANEL
N° C3693
POWER SUPPLY
Art. 931A/C17
MAINS
PHONE
Art. 6200
PHONE
Art. 8875
Art. 8872
N.B.
IN CASE OF NOISE IN THE AUDIO MOVE, IN
THE POWER SUPPLY, THE WIRE CONNECT-
ED ON THE DOOR LOCK TERMINAL N. 15 TO
TERMINAL AS.
A- Entrance panel
series Patavium
8000, 8100, 1200, 3300
B- Additional push-button for lock
C- Electric lock 12V
D- Outdoor unit
Art.930, 930A
L1- Bulb for panel lighting
(3x24V 3W max.)
10x24V 3W with Art. 832/C17
16X24V 3W with Art. 832/3C7
4
AC
C
AS
BL
BI
RO
A+
A-
R
6E
AU
6E
A
C
22
6E
6P
6S
6
5
33
AU
1
7
E
1
3
7
8
6
1
2
CH
123S
4
3
8
5
6
7
B
D
C
A
CP1 3-2
PRI
6 8 C1C2 7 O AS15
L1
WIRING DIAGRAM OF ELECTRIC DOOR-OPENER SYSTEM WITH CALL SYSTEM "SOUND
SYSTEM", CONVERSATION PRIVACY, DIRECT LOCK RELEASE AND FOR NOTICE OF CALL
IN DOOR ENTRY PANEL.
N° C3762
MAINS
PHONE
Art. 8878
POWER SUPPLY
Art. 931A/C17
A- Entrance panel series Patavium
8000, 8100, 1200, 3300
B- Additional push-button for lock
C- Electric lock 12V
D- Outdoor unit
Art.930, 930A
E- Card for conversation privacy Art. 6155
L1- Bulb for panel lighting
(3x24V 3W max.)
10x24V 3W with Art. 832/C17
16X24V 3W with Art. 832/3C7
PHONE
Art. 6200 + Art. 6155
N.B.
On interphone Art. 8878 leave the
jumper on terminals “C-AS”.
5
R
AC
C
AS
BL
BI
RO
A+
A-
Art.8878
S3
21 CH
E
CN1
6E
8
6C
A
4
8
6S
6P
7
3
6E
5
1
2
AU
6
7
2
3
1
3
6E
1
2
AU
7
6
5
8
3
4
B
12345
D
A
PRI
3-1 2 C2 86 7 C1 CP 15O AS
C
L1
N° C3763
PHONE
Art. 8878
POWER SUPPLY
Art. 931A/C17
WIRING DIAGRAM OF ELECTRIC DOOR-OPENER SYSTEM WITH CALL SYSTEM "SOUND
SYSTEM", CONVERSATION PRIVACY, LOCK RELEASE AFTER THE CALL AND FOR
NOTICE OF CALL IN DOOR ENTRY PANEL.
RELAY
Art. 170/101
PHONE
Art. 6200 + 6155 + 6152
MAINS
A- Entrance panel series Patavium
8000, 8100, 1200, 3300
B- Additional push-button for lock
C- Electric lock 12V
D- Outdoor unit
Art.930, 930A
L1- Bulb for panel lighting
(3x24V 3W max.)
10x24V 3W with Art. 832/C17
16X24V 3W with Art. 832/3C7
N.B.
On interphone Art. 8878 displace
jumper on terminal “AC-C”.
6
ELVOX
L1
1 CHS23
B
1 3-2
PRI
6 8 C1C2 7
C
3
7
8
D
5
6
4
CP O AS15
A
5
8
7
6
1
3
4
2
B
7
3
5
6
4
1
2
B
WIRING DIAGRAM OF ELECTRIC DOOR ENTRY SYSTEM WITH “A.C.” CALL AND CALL
ON DOOR ENTRY PANEL.
N° C3694
PHONE
Art. 8870
N.B.
IN CASE OF NOISE IN THE AUDIO MOVE,
IN THE POWER SUPPLY, THE WIRE CON-
NECTED ON THE DOOR LOCK TERMINAL
N. 15 TO TERMINAL AS.
PHONE
Art. 620R
MAINS
A- Entrance panel series Patavium
8000, 8100, 1200, 3300
B- Additional push-button for lock
C- Electric lock 12V
D- Outdoor unit Art.930, 930A
L1- Bulb for panel lighting
(3x24V 3W max.)
10x24V 3W with Art. 832/C17
16X24V 3W with Art. 832/3C7
POWER SUPPLY
Art. 931A/C17
7
VARIAZIONI DEGLI SCHEMI BASE
VERSIONS FROM STANDARD WIRING DIAGRAMS
VERSION 1
Connection of outdoor call push-button.
When activating the outdoor push-button the phone sounds with
a tone different from the one obtained by the external entrance
panel call.
A- Outdoor push-button
POWER SUPPLY
Art. 931A/C17
PHONE
Art. 8875
Art. 8878
Art. 6200 (6P)
(6P)
(6S)(6P)
VERSION 2
Connection of the call repeater Art. 2/841.
The loudspeaker module Art. 2/841 repetes the phone
sound leaving the tone unaltered.
PHONE
Art. 8875
Art. 8878
Art. 6200 (6P)
Call repeater
Art. 2/841
VERSION 3
Connection of stair-lighting push-button
by using repeater relay Art. 170/001.
N.B. To switch on stair-light press push-button with bulb symbol . The maximum capacity of the phone button contacts is 24V 0.5A A.C./D.C.
RELAY
Art. 170/001
STAIR-LIGHT PUSH-BUTTON
Max. load
3A-230V
PHONE
Art. 8875
Art. 8878
Art. 6200 (6P)
Art. 8870
MAINS
MAINS
POWER SUPPLY
Art. 931A/C17
MAINS
POWER SUPPLY
Art. 931A/C17
(6S)
VERSION 4
Connection of additional bell.
12V
additional bells can be fitted using the relay Art. 170/101 connected
as shown in the diagram.
Bell supply
PHONE
Art. 8875
Art. 8878
Art. 6200 (6P)
RELAY
Art. 170/101
Max. load
3A-230V
Tipical section Terminals Ø up to 50 m. Ø up to 100 m. Ø up to 200 m.
a 0, 3, 12, 15, -, AS, S1
C1, C2, C3, P1, P2 0,5 mm20,75 mm21,5 mm2
lock, calls
b others 0,25 mm20,5 mm21 mm2
MINIMAL CONDUCTORS SECTION FOR DOOR ENTRY SYSTEMS (mm2)
Section mm20,12 0,25 0,35 0,50 0,75 1,00 1,50 2,50 4,00 6,00
Diameter mm. 0,40 0,58 0,68 0,80 1,00 1,15 1,40 1,80 2,30 2,80
AWG 262322201816141210
Decimal diameter 4/10 6/10 8/10 10/10 12/10 14/10 18/10
Resistance Ω100m. 14,00 6,60 4,80 3,50 2,20 1,70 1,14 0,69 0,39 0,28
Conversion table of sections-diameters and relative resistances for 100 m. standard conductors.
CERT n° 9110.ELVO
UNI EN ISO 9001:2008
ELVOX Austria GmbH
Grabenweg 67
A-6020 Innsbruck
Milano
Via Conti Biglia, 2
20162 Milano
Padova
Via A. Ferrero, 9
35133 Padova
Torino
Strada del Drosso, 33/8
10135 Torino
ELVOX Shanghai Electronics Co.
3. Floor No. 2 Bulding No. 1898 Lai Yin Road
Hi-Tech Park SongJiang, Jiu Ting District
Shanghai 201615
FILIALI ITALIA FILIALI ESTERE
ELVOX Costruzioni elettroniche S.p.A. - ITALY
Via Pontarola, 14/a - 35011 Campodarsego (Padova)
Tel 049 9202511 - Fax 049 9202603 - info@elvox.com
Telefax Export Dept. +39/049 9202601 - elvoxexp@elvox.com www.elvox.com

Navigation menu