5990 7580_pxi Dm_2 17 12_d3a A_M9183A A M9183A
User Manual: A_M9183A
Open the PDF directly: View PDF .
Page Count: 14
Download | |
Open PDF In Browser | View PDF |
Agilent PXI Digital Multimeters Data Sheet 6½ Digit, High Performance M9182A M9183A • 6½ digit resolution • High throughput: up to 15,000 rdgs/sec, 66 µs single reading interval • DCV basic one year accuracy: 40 ppm • Ten standard measurements: DCV, ACV, DCI, ACI, 2- and 4-wire resistance, frequency, period, capacitance, and temperature • Floating isolation (CAT II) up to 300 V TM Discover the Alternatives... ... Agilent Modular Products O VERV IE W Agilent’s M9182A and M9183A 6½ digit high performance PXI digital multimeters (DMMs) offer fast throughput, flexible measurements, and trustworthy results. The M9182A provides ten built-in measurement types with all the accuracy and stability you would expect from an Agilent 6½ digit DMM. The M9183A provides the same capabilities as the M9182A, with market-leading measurement speed of up to 15,000 readings per second, additional ranges, and a DC source. F eatures I n du s tr ies a n d A p p l i c a t i o n s • DCV, ACV, DCI, ACI, 2- and 4-wire resistance, frequency, period, capacitance, and temperature • 6½ digit resolution • Up to 15,000 readings per second, 66 µs single reading interval time (M9183A) • Up to 4,500 readings per second, 222 µs single reading interval time (M9182A) • Basic 1 year DCV accuracy of 40 ppm • Aerospace and defense • Automotive electronics test • Pulse width, duty cycle, and totalizer/event counter (M9183A) • Industrial electronics test • DC voltage and current source (M9183A) • Medical device test • External trigger in and DMM out, to synchronize with external multiplexers and instruments • Semiconductor and component test • Analog threshold trigger with pre- and post- levels for measuring the correct signal • Floating isolation (CAT II) to 300 V • Software drivers to support most common programming environments • Chassis connector compatibility: PXI-1 (J-1 only), PXIe hybrid slot Customer Values • Measurements you can trust • Higher test throughput due to the lowest latency • Application development in the environment of your choice reduces development time • Customer supportable calibration procedures as well as calibration services available from Agilent PXI-DMM M918xA Feature Summary All three products are 6½ digit PXI DMMs that take DCV, ACV, DCI, ACI, 2- and 4-wire resistance measurements. DMM Description DCV basic Maximum 1 year reading rate at accuracy 4½ digits Other measurements Triggering DC source M9181A* Basic features PXI DMM High performance PXI DMM Enhanced performance PXI DMM 90 ppm 150 rdgs/sec None Immediate n/a 40 ppm 4,500 rdgs/sec M9182A M9183A 40 ppm Temperature, capacitance, frequency, period 15,000 rdgs/sec Temperature, capacitance, frequency, period, offset compensated Ω, pulse width, duty cycle, totalizer/ event counter Immediate, analog n/a threshold, PXI trigger bus, external Immediate, analog ± 10 V threshold, PXI trigger ± (1.2 µA to 12 mA) bus, external *This table and more information about the M9181A can be found in the M9181A data sheet, literature number 5990-9035EN. 2 E ASY SET UP … T ES T … A N D M A I N T E N A N C E H a r d w a r e P l a t f o rm Compliance Easy software integration The M9182A and M9183A 6½ digit DMMs are PXI compliant, using either a cPCI (J1), PXI-1 (J1) or PXIe Hybrid slot. Designed to benefit from fast data interfaces, an M9182A or M9183A DMM can be integrated with other test and automation modules in a PXI, CompactPCI, or Hybrid chassis. The PXI format offers high performance in a small, rugged package. It is an ideal deployment platform for many automated test systems. A wide array of complementary PXI products are currently available. Products from Agilent include switches, multiplexers, digitizers, waveform generators, and local oscillators. Application code examples are included for LabVIEW, Visual Basic, C/C++, C#, and MATLAB – demonstrating DMM set up and basic functionality. These application code examples can be used to help you integrate the DMM module into your measurement system. Soft front panel The soft front panel provides easy to use instrument control. The M9182A and M9183A graphical user interface guides developers through module setup so users can quickly configure the DMM. S oftw a r e P l a t f o r m IO Libraries Suite Agilent IO Libraries Suite offers fast and easy instrument connections. IO Libraries Suite 16.1 supports PXI, helping you display all of the modules in your system, view information about installed software and allows you to more easily find the right driver and start module soft front panels directly with Agilent Connection Expert. National Instruments IO libraries are also supported, and may be used along with Agilent IO libraries. Figure 1. M9183A soft front panel Drivers One notable feature of the soft front panel is the Driver Call Log which allows the user to see the driver calls for each button pushed. The user can then incorporate the driver calls into the their application program – enabling fast and easy program development. Agilent’s digital multimeters come complete with software drivers for Windows® XP, Windows Vista, and Windows 7 (32 and 64 bit). These software drivers work in the most popular test and measurement development environments including: LabVIEW, Visual Studio® (C, C++, C#, Visual Basic), MATLAB, and VEE. Calibration Each M9182A and M9183A DMM is factory calibrated and shipped with an ISO-9002, NIST-traceable calibration certificate. Calibration is required once per year. A documented calibration process allows you to do in-rack calibration using standard calibration sources. Alternatively, Agilent and 3rd party calibration labs offer calibration services for the M9182A and M9183A DMMs. 3 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S M9182A and M9183A: Accuracy specifications ±(% of reading + % of range) 1,2 Function Range 3 DC voltage True RMS, AC voltage 4,5 (Fast RMS off) True RMS, AC voltage4,5 (Fast RMS on) Frequency 24 hour 23 °C ± 1 °C 90 day 23 °C ± 5 °C 1 year 23 °C ± 5 °C 200.0000 mV 2.000000 V 20.00000 V 200.0000 V 300.0000 V 0.0030 + 0.0005 0.0020 + 0.0002 0.0040 + 0.0006 0.0030 + 0.0002 0.0130 + 0.0002 0.0040 + 0.0008 0.0030 + 0.0002 0.0050 + 0.0007 0.0040 + 0.0001 0.0230 + 0.0003 0.0050 + 0.0010 0.0040 + 0.0003 0.0070 + 0.0008 0.0050 + 0.0003 0.0250 + 0.0003 200.0000 mV6 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 3.00 + 0.18 0.37 + 0.08 0.13 + 0.05 0.25 + 0.08 1.90 + 0.18 3.10 + 0.19 0.38 + 0.09 0.14 + 0.06 0.26 + 0.10 1.95 + 0.19 3.20 + 0.22 0.40 + 0.10 0.15 + 0.06 0.27 + 0.12 2.00 + 0.20 2.000000 V 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 3.00 + 0.10 0.37 + 0.07 0.05 + 0.05 0.32 + 0.06 1.90 + 0.08 3.10 + 0.11 0.38 + 0.08 0.06 + 0.06 0.33 + 0.07 2.00 + 0.09 3.20 + 0.13 0.40 + 0.09 0.07 + 0.06 0.35 + 0.08 2.10 + 0.10 20.00000 V 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 3.00 + 0.07 0.37 + 0.06 0.06 + 0.05 0.18 + 0.09 1.30 + 0.15 3.10 + 0.08 0.38 + 0.07 0.07 + 0.06 0.20 + 0.11 1.40 + 0.18 3.30 + 0.10 0.40 + 0.08 0.07 + 0.07 0.22 + 0.13 1.50 + 0.20 200.0000 V & 300.0000 V 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 3.00 + 0.07 0.43 + 0.06 0.07 + 0.05 0.28 + 0.07 1.30 + 0.09 3.10 + 0.08 0.44 + 0.07 0.08 + 0.07 0.30 + 0.08 1.60 + 0.12 3.30 + 0.08 0.45 + 0.08 0.09 + 0.08 0.32 + 0.10 2.40 + 0.13 200.0000 mV6 350 Hz - 800 Hz 800 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 0.60 + 0.08 0.13 + 0.05 0.55 + 0.08 5.30 + 0.18 0.65 + 0.09 0.14 + 0.06 0.60 + 0.10 5.40 + 0.19 0.70 + 0.10 0.15 + 0.06 0.63 + 0.12 5.60 + 0.20 2.000000 V 350 Hz - 800 Hz 800 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 0.93 + 0.07 0.07 + 0.05 0.62 + 0.06 5.10 + 0.08 0.96 + 0.08 0.08 + 0.06 0.65 + 0.07 5.20 + 0.09 1.00 + 0.09 0.08 + 0.06 0.70 + 0.08 5.30 + 0.10 20.00000 V 350 Hz - 800 Hz 800 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 0.93 + 0.06 0.07 + 0.05 0.31 + 0.09 2.00 + 0.15 0.96 + 0.07 0.07 + 0.06 0.33 + 0.11 2.20 + 0.18 1.00 + 0.08 0.07 + 0.07 0.35 + 0.13 2.40 + 0.20 200.0000 V & 300.0000 V 350 Hz - 800 Hz 800 Hz - 10 kHz 10 kHz - 50 kHz 50 kHz - 100 kHz 1.00 + 0.06 0.07 + 0.05 0.34 + 0.07 2.50 + 0.09 1.10 + 0.07 0.07 + 0.07 0.45 + 0.08 2.80 + 0.12 1.10 + 0.08 0.08 + 0.08 0.50 + 0.10 3.20 + 0.13 4 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S M9182A and M9183A: Accuracy specifications ±(% of reading + % of range) 1,2 Function Range 3 Frequency, test current or burden voltage 24 hour 23 °C ± 1 °C 90 day 23 °C ± 5 °C 1 year 23 °C ± 5 °C Resistance 7 20.00000 Ω (M9183A only) 200.0000 Ω 2.000000 kΩ 20.00000 kΩ 200.0000 kΩ 2.000000 MΩ 20.00000 MΩ 200.0000 MΩ (M9183A , 2-wire only) 10 mA 0.004 + 0.004 0.009 + 0.004 0.014 + 0.005 1 mA 1 mA 100 µA 10 µA 1 µA 100 nA 4 nA 0.004 + 0.002 0.003 + 0.002 0.003 + 0.002 0.006 + 0.002 0.018 + 0.002 0.120 + 0.002 0.800 + 0.013 0.010 + 0.002 0.008 + 0.002 0.008 + 0.002 0.010 + 0.002 0.030 + 0.003 0.130 + 0.003 1.000 + 0.015 0.013 + 0.003 0.012 + 0.002 0.012 + 0.002 0.016 + 0.003 0.040 + 0.004 0.200 + 0.003 1.300 + 0.025 200.0000 nA (M9183A only) 2.000000 µA (M9183A only) 20.00000 µA (M9183A only) 200.0000 µA (M9183A only) 2.000000 mA 20.00000 mA 200.0000 mA 2.000000 A < 100 µV 0.130 + 0.020 0.160 + 0.023 0.170 + 0.030 < 100 µV 0.050 + 0.004 0.080 + 0.003 0.210 + 0.008 < 100 µV 0.050 + 0.002 0.080 + 0.003 0.130 + 0.004 < 2.5 mV 0.052 + 0.100 0.070 + 0.150 0.100 + 0.200 < 25 mV < 250 mV < 55 mV < 520 mV 0.020 + 0.015 0.020 + 0.002 0.020 + 0.025 0.100 + 0.003 0.030 + 0.020 0.035 + 0.003 0.030 + 0.030 0.150 + 0.004 0.040 + 0.028 0.045 + 0.003 0.040 + 0.040 0.200 + 0.005 2.000000 mA 9 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 1 kHz 1 kHz - 10 kHz 2.70 + 0.20 0.90 + 0.20 0.04 + 0.08 0.12 + 0.20 2.90 + 0.20 0.90 + 0.20 0.08 + 0.15 0.14 + 0.20 2.90 + 0.20 1.00 + 0.20 0.12 + 0.20 0.22 + 0.20 20.00000 mA 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 1 kHz 1 kHz - 10 kHz 1.80 + 0.15 0.60 + 0.15 0.07 + 0.05 0.21 + 0.15 2.60 + 0.15 0.90 + 0.15 0.15 + 0.10 0.30 + 0.20 2.80 + 0.15 1.00 + 0.15 0.16 + 0.15 0.40 + 0.20 200.0000 mA 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 1 kHz 1 kHz - 10 kHz 1.80 + 0.20 0.60 + 0.20 0.15 + 0.08 0.30 + 0.15 2.70 + 0.20 0.90 + 0.20 0.17 + 0.09 0.35 + 0.18 2.80 + 0.20 1.00 + 0.20 0.20 + 0.11 0.40 + 0.20 2.000000 A 10 Hz - 20 Hz 20 Hz - 47 Hz 47 Hz - 1 kHz 1 kHz - 10 kHz 1.80 + 0.20 0.66 + 0.30 0.30 + 0.19 0.40 + 0.20 2.50 + 0.23 0.80 + 0.30 0.33 + 0.19 0.45 + 0.23 2.70 + 0.25 0.90 + 0.30 0.35 + 0.20 0.50 + 0.25 200 mV to 300 V 1Hz - 20 Hz 20 Hz - 130 Hz 130 Hz - 640 Hz 640 Hz - 2.5 kHz 2.5 kHz - 40 kHz 40 kHz - 200 kHz 200 kHz - 300 kHz 0.08 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.05 + 0.01 0.07 + 0.01 0.08 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.05 + 0.01 0.07 + 0.01 0.08 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.03 + 0.01 0.05 + 0.01 0.07 + 0.01 DC current True RMS, AC current 8 Frequency or period 10, 14 5 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S M9182A and M9183A: Accuracy specifications ±(% of reading + % of range) 1,2 Function Range Full scale reading 24 hour or resolution 23 °C ± 1 °C 90 day 23 °C ± 5 °C 1 year 23 °C ± 5 °C Single shot duty cycle 11 [M9183A only] 2 - 100 Hz 100 Hz - 1 kHz 1 - 10 kHz 0.02 % 0.20 % 2.00 % 0.03 ± 0.03 0.03 ± 0.30 0.03 ± 3.00 0.03 ± 0.03 0.03 ± 0.30 0.03 ± 3.00 0.03 ± 0.03 0.03 ± 0.30 0.03 ± 3.00 Single shot pulse width 12, 14 [M9183A only] 14 μs - 62.5 ms 1 µs .01 ± 4 µs 01 ± 4 µs 01 ± 4 µs Capacitance 13 1000.0 pF 10.000 nF 100.00 nF 1.0000 µF 10.000 µF 100.00 µF 1.0000 mF 10.000 mF 1199.9 pF 11.999 nF 119.99 nF 1.1999 µF 11.999 µF 119.99 µF 1.1999 mF 11.999 mF 1.00 + 0.10 1.20 + 0.05 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.20 + 0.10 2.00 + 0.10 1.00 + 0.10 1.20 + 0.05 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.20 + 0.10 2.00 + 0.10 1.00 + 0.10 1.20 + 0.05 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.00 + 0.10 1.20 + 0.10 2.00 + 0.10 [M9183A and M9182A] 1. Specifications are for 1 hour warm up, within 1 hour self-cal, aperture ≥ 0.5 sec. Slow AC filter for AC measurements only. 2. For temperatures outside the range of 23 °C ± 5 °C, but within 0 °C to 50 °C, add 0.1 × accuracy specification per °C. 3. 20% over range on all ranges except 300 V range, 10% over range for 300 V range. 4. Minimum input specified: 5 mV or 1% of range, whichever is larger. 5. Signal is limited to 8x106 Volt Hz product. For example, at 32 kHz, the highest input is 250 V. 6. For inputs from 5 mV to 15 mV, add 100 µV to the specification. 7. Specifications are for 4-wire resistance measurements, for 2-wire, add 1 mΩ additional error to the specification; for offset compensated ohms (M9183A only), add 0.02% of range. 8. Minimum input specified: 60 µA or 1.5% of range, whichever is larger; for inputs < 5% of full scale, add 0.02% of range. 9. For inputs from 60 to 120 µA, add 10 µA to the specification; for inputs < 5% of full scale, add 0.1% of range. 10. Minimum amplitude greater of: 100 mV, or 5 % of range for 1 Hz to 2.5 kHz, or 25 % of range for 2.5 kHz to 200 kHz , or 40% of range for 200 kHz to 300 kHz.. 11. Specifications are % of reading (0.03) ± adder. 12. Specifications are % of reading + time. 13. Specifications apply to input signals ≥ 5% of range. 14. Maximum wait time for duty cycle and period is 5 seconds. Defin itions f o r s p e c i f i c a t i o ns Specification (spec): Represents warranted performance of a calibrated instrument that has been stored for a minimum of two hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a one hour warm-up period. The specifications include measurement uncertainty. Data represented in this document are specifications unless otherwise noted. Typical (typ): Represents characteristic performance, which 80% of the instruments manufactured will meet. This data is not warranted, does not include measurement uncertainty, and is valid only at room temperature (approximately 25 °C). Nominal (nom): The expected mean or average performance, or an attribute whose performance is by design, such as the 50 Ω connector. This data is not warranted and is measured at room temperature (approximately 25 °C). Measured (meas): An attribute measured during the design phase for purposes of communicating expected performance, such as amplitude drift vs. time. This data is not warranted and is measured at room temperature (approximately 25 °C). Note: All graphs contain measured data from several units at room temperature unless otherwise noted. 6 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S M9182A and M9183A Sensitivity (nom) Function Lowest Range Sensitivity DCV 200.0000 mV 0.1 µV ACV 200.0000 mV 0.1 µV Resistance (M9183A) 20.00000 Ω 10 µΩ Resistance (M9182A) 200.0000 Ω 100 µΩ DCI (M9183A) 200.0000 nA 0.1 pA DCI (M9182A) 2.000000 mA 10 nA ACI 2.000000 mA 1 nA Capacitance 1000.0 pF 0.1 pF M9182A and M9183A temperature accuracy (spec) 1 Temperature function Type R0 (Ω) Sensitivity Range/max temperature 1 year 23 °C ± 5 °C RTD temperature measurement 2,3 pt385 100 Ω, 200 Ω 0.01 °C -150 to 650 °C ± 0.06 °C 500 Ω, 1 kΩ 0.01 °C -150 to 650 °C ± 0.03 °C Less than 12 Ω 0.01 °C -100 to 200 °C ± 0.18 °C at ≤ 20 °C ± 0.05 °C otherwise Higher than 90 Ω 0.01 °C -100 to 200 °C ± 0.10 °C at ≤ 20 °C ± 0.05 °C otherwise B NA 0.01 °C 2200 °C ± 0.38 °C E NA 0.01 °C 1200 °C ± 0.035 °C J NA 0.01 °C 2000 °C ± 0.06 °C K NA 0.01 °C 3000 °C ± 0.07 °C N NA 0.01 °C 3000 °C ± 0.10 °C R NA 0.01 °C 2700 °C ± 0.25 °C S NA 0.01 °C 3500 °C ± 0.35 °C T NA 0.01 °C 550 °C ± 0.06 °C 2.25 kΩ NA 0.01 °C -80 to 150 °C ± 0.1 °C 5 kΩ NA 0.01 °C -80 to 150 °C ± 0.1 °C 10 kΩ NA 0.01 °C -80 to 150 °C ± 0.1 °C Cu (Copper) Thermocouple temperature measurement 4,5 Thermistor 3 1. Specifications are for one hour warm up, within one hour self-cal, aperture ≥ 0.5 sec. 2. 4-wire RTD measurement, R0 variable 1 Ω to 7 k Ω. 3. For total measurement accuracy, add temperature probe error. 4. For total measurement accuracy, add thermocouple error and cold junction compensation. 5. DMM linearization temperature range may be greater than that of the thermocouple device. 7 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S Source-Measure [(spec) unless otherwise stated)] M9183A source DC voltage, measure DC voltage Parameter Closed Loop Open Loop DC voltage source (output) range +10 to -10 V +10 to -10 V DC source sink current at 5 V output 5 mA 5 mA DAC resolution (nom) 18 bits /12 bits 12 bits DC voltage source accuracy 1 Year, 23°± 5° C 0.01% ± 0.001% 0.5% ± 0.2% Settling time (typ) 100 ms/1 ms 1 ms Source resistance (nom) 200 ohms 200 ohms M9183A source DC voltage, measure DC current DC voltage source (output) range -10.000 to +10.000 V DC current measurement range 0 to ± 20 mA Voltage resolution (nom) 5 mV Voltage source accuracy 1 Year, (23 °C ± 5 °C) 1,2,3,4 2.0% ± 0.4% Settling time (typ) 100 ms DC current measurement accuracy 0.1% + 0.005% M9183A source DC current, measure DC voltage DC voltage measurement range 0 to ± 2.0 V Current output Compliance voltage Minimum Level Source Accuracy 1 year, (23 °C ± 5 °C) 1,2,3 < 1.25 µA 4.2 V 10 nA 1% + 1% < 12.5 µA 4.2 V 50 nA 1% + 1% < 125 µA 4.2 V 100 nA 1% + 0.5% < 1.25 mA 4.2 V 1 µA 1% + 0.5% < 12.5 mA 1.2 V 10 µA 1% + 0.5% 1. Specifications are for one hour warm up, within one hour self-cal, slow AC filter. 2. For temperatures outside the range of 23 °C ± 5 °C, but within 0 °C to 50 °C, add 0.1 × accuracy specification per °C. 3. Repetitive reading at an aperture of 133 ms or higher. 4. If DCV source > 6 V, then add current * 4 ohms; if DCV source > 8 V, then add current * 30 ohms. 8 T E CH NIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S Triggering Characteristics The M9182A and M9183A have advanced triggering capabilities that exceed those found on other digital multimeters. Advanced triggering enables you to obtain the signal you need and accurately measure it, in a variety of applications. External hardware trigger Trigger input voltage level range (at DIN 7 connector) +3 to +15 V activates the trigger Minimum trigger pulse width Aperture + 50 µs Trigger input impedance 3 kΩ Edge Selectable positive or negative edge PXI bus trigger inputs Trigger input voltage level range (via PXI backplane) CMOS level (see PXI standard) Minimum trigger pulse width Aperture + 50 µs Edge Selectable positive or negative edge Trigger features Trigger sources Trigger delay [Auto delay (default delay) ensures 1st reading accuracy in most configurations) Immediate, PXI trigger , external DIN connector, analog threshold trigger source Measurement delay 50 µs to 15 s Resolution 1 µs to 65 ms and 16 µs above 65 ms Reading storage Multi Sample Mode Circular buffer - 80 readings Aperture range (DCV and DCI functions only) 2.5 µs to 160 ms (M9183A) 130 µs to 160 ms (M9182A) Maximum read interval range 1sec for aperatures ≥ 625 µs, else 65 ms Reading per trigger Up to 80 readings (maximum of 78 pre-triggers or a maximum of 80 post triggers) Trigger sources PXI trigger, external DIN connector, and analog threshold (accuracy within 5% of range) 9 M EAS U R EM E N T CH A RA CT E R I S TICS Resolution vs. Aperture and Reading Rate for DCV, DCI, Ω Measurement aperture Maximum readings per second Resolution 10 ms 98 6½ digits (22 bits) 625 µs 1,200 5½ digits (18 bits) 14,000 130 µs 4,500 4½ digits (14 bits) 10,000 2.5 µs 15,000 4½ digits (14 bits) (M9183A only) 1 8,000 Aperture reading rate (< 1 NPLC) 16,000 12,000 6,000 4,000 2,000 1. 15,000 readings/second represent a typical maximum with a measurement aperture of 2.5 µs. Results will vary, depending on what PC hardware, PXI hardware, and driver are used. 10 mS 625 µS 130 µS M9182A 2.5 µS M9183A Transaction Speed Transactional I/O speed is a single reading measurement. This is important when you are taking many single measurements with the DMM. The M9183A delivers the highest transactional measurement speed in its class. These fast readings, up to 15,000 readings per second with a read interval rate of 66 µs, provides the lowest latency, translating into higher test-system throughput and lower cost of test per unit tested. Variable delay can be programmed to allow fully settled readings in most configurations. Time frame of a single measurement Minimum read interval = 66 µs (M9183A) Minimum read interval = 222 μs (M9182A) System Reading and Throughput Rates Switching ranges within a function Aperture (A) Range change time (ms) Switch between functions Aperture (A) Function change time (ms) DCV A ≤ 20 ms (A × 0.2) + 15 DCV A < 16 ms 15.6 A > 20 ms A + 15.6 A ≥ 16 ms A + 25 Resistance (2wire or 4-wire) A < 33 ms (A × 0.05) + 15.5 A < 16.66 ms 7.8 A ≥ 33 ms A + 13 DCI (200 mA or 2 A to any other range) A ≤ 40 ms 4.2 40 ms < A < 66.66 ms 7.8 A > 40 ms 15.7 A ≥ 66.66 ms (A × 0.51) + 45 DCI (all other ranges) All apertures DCV to capacitance A < 33.33 ms 23.4 A ≥ 33.33 ms (A × 0.65) + 50 Capacitance All apertures Resistance to capacitance A ≤ 33.33 ms 23.4 Resistance to DCI 1 12 10 16.66 ms ≤ A < 40 ms A × 0.65 33.33 ms < A < 80 ms (A × 2) + 35 80 ms ≤ A < 160 ms 23.4 A ≥ 160 ms 160 M EAS U R EM E N T CH A RA CT E R I S TICS DC voltage Measurement method Delta-sigma A/D conversion Input resistance 200 mV, 2.0 V ranges: >10 GΩ with typical leakage of < 50 pA; 20 V, 200 V, 300 V ranges: 10.0 MΩ Input isolation 330 VDC, 250 VAC from Earth ground Input overvoltage protection 330 VDC all ranges DCV noise rejection Normal mode rejection at 50, 60, or 400 Hz ± 0.5%; > 95 dB (apertures ≥ 0.160 s); CMRR (1 kΩ lead imbalance) ≥ 120 dB True RMS AC voltage Measurement method AC coupled (10 Hz to 100 kHz) true RMS — measures the AC component of an input waveform that consists of AC and DC components. Crest factor Maximum crest factor of 4 at full scale, 7 at 10% of range Input impedance 1 MΩ, in parallel with < 300 pF Settling time < 0.5 sec to within 0.1% of final value Fast RMS: < 0.05 sec to within 0.1% of final value Peak input 8 x 106 volt Hz product (example: 250 V @ 32 kHz) Input overvoltage protection 330 VAC all ranges ACV noise rejection Common mode rejection at 50 Hz or 60 Hz; 1 kΩ imbalance in either lead > 60 dB Resistance Measurement method Selectable 2-wire or 4-wire. Current source referenced to LO output Offset compensation (M9183A only) All ranges, use with apertures > 5 ms Voffset + (I*R) < 2.2 V for ranges ≥ 2 kΩ Voffset + (I*R) < 0.22 V for ranges < 2 kΩ Maximum test voltage 240 mV for 20 Ω and 200 Ω ranges; 2.4 V for 20 kΩ to 20 MΩ ranges; 1.0 V for 200 MΩ range (M9183A only) Maximum lead resistance (4-wire) 50 kΩ for 200 kΩ, 2.0 MΩ, and 20 MΩ ranges; 5 kΩ for 20 kΩ range 500 Ω for 200 Ω and 2 kΩ ranges; 50 Ω for 20 Ω range Input protection 330 V on all ranges DC current Shunt resistance 10 Ω for 2 mA and 20 mA, 0.1 Ω for 200 mΩ and 2 A; Virtual zero shunt for 200 μA, 20 μA, 2 μA, and 200 nA range (M9183A only) Input protection Protected with 2.5 A, 250 V fast blow fuse True RMS AC current Measurement method AC coupled true RMS measurement (measures the AC component only.) analog RMS DC converter. Shunt resistance 10 Ω for 2 mA and 20 mA, 0.1 Ω for 200 mA and 2 A Input protection Protected with 2.5 A, 250 V fast blow fuse 11 M EAS U R EM E N T CH A RA CT E R I S TICS Frequency and period Measurement method Direct (conventional) counting Input impedance 1 MΩ with < 300 pF Sensitivity (130 Hz) .001 Hz Totalizer (M9183A only) Active edge polarity Positive or negative transition Maximum count 10,000,000,000 Allowed rate 1 to 30,000 events per second Threshold Set threshold DAC Accuracy ±2 counts Capacitance Measurement method Differential charge balance: variable currents used to stimulate dV/dt response. Connection type 2-wire Environmental and physical characteristics Temperature range Operating -10° to 55 °C Non-operating -40 ° to +85 °C Relative humidity Operating to 80% at 40 °C Storage to 95% at 40 °C Connectors V HI*, 2-wire Ω IN, DCV OUT V LO*, 2-wire Ω IN, DCV OUT I HI*, 4-wire Ω IN I LO*, 4-wire Ω IN Sync OUT External Trigger IN Trigger and Sync common Safety Complies with IEC 61010-1, CAT II 300 V, pollution degree 2 EMC Complies with EN61326-1 Industrial Environment Warm-up time 1 hour Sheathed banana jack Sheathed banana jack Sheathed banana jack Sheathed banana jack DIN 7, pin 2 DIN 7, pin 7 DIN 7, pin 4 * Do not connect the V HI and V LO or I HI and I LO connectors to anything when the measurement function does not utilize those connectors. Physical characteristics Power dissipation: Dimensions 3U/1-slot PXI/CompactPCI standard +5 V Total power Weight 0.5 kg (1 lb.) 300 mA 1.5 W max 12 C O N FI G U RA T I O N Hardware Calibration and Warranty Model Description Advantage services: calibration and warranty M9182A PXI 6½ digit multimeter, high performance M9183A PXI 6½ digit multimeter, enhanced performance Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. DMM units include: Getting started guide, software drivers, user and service documentation (on CD ROM), Agilent I/O libraries Calibration Software Model Description Supported Operating Systems Microsoft Windows XP (32-bit), Microsoft Windows Vista (32/64-bit) Microsoft Windows 7 (32/64-bit) Standard Compliant Drivers IVI-C, IVI-COM, LabVIEW Yearly calibration, for 3 years R-50C-011-5 Yearly calibration, for 5 years R-50C-021-3 Yearly ANSI Z540-1-1994 calibration, for 3 years R-50C-021-5 Yearly ANSI Z540-1-1994 calibration, for 5 years Warranty Standard warranty is 1 year R-51B-001-3C 1 year return-to-Agilent warranty extended to 3 years Supported VisualStudio (VB.NET, C#, C/C++)®, Application LabVIEW, MATLAB, VEE Development Environments (ADE) Agilent IO Libraries R-50C-011-3 R-51B-001-5C 1 year return-to-Agilent warranty extended to 5 years Accessories Includes: VISA Libraries, Agilent Connection Expert, IO Monitor Model Description 34138A Test lead set Related products 13 Model Description M9018A 18-slot PXIe chassis M9021A PCIe cable interface to an external system controller M9036A Embedded controller M9101A PXI high-density multiplexer, 64 channels, reed relays M9103A PXI high-density multiplexer, 99 channels, armature relays M9120A PXI high-density matrix switch, 4x32, armature relays M9121A PXI high-density matrix switch, 4x64, reed relays M9181A PXI digital multimeter, 6½ digit, basic features T h e Mo d u l ar Tang r am The four-sided geometric symbol that appears throughout this document is called a tangram. This seven-piece puzzle originated in China a few centuries ago. The goal is to create shapes—from simple to complex—that form an identifiable silhouette. As with a tangram, the possibilities may seem infinite as you begin to create a new test system. With a set of clearly defined elements— architecture, hardware, software—Agilent can help you create the system you need, from simple to complex. Discover the Alternatives … ... Agilent Modular Products Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/find/advantageservices www.agilent.com/quality PXI is a registered US trademark of PXI Systems Alliance. Visual Studio, Visual C, C++, and C#, and Visual Basic are registered trademarks of Microsoft Corporation. Windows and MS Windows are U.S. registered trademarks of Microsoft Corporation. MATLAB is a U.S. registered trademark of The Math Works, Inc. Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2012 Printed in USA, February 17, 2012 5990-7580EN w w w .ag i l ent.co m www.agilent.com/find/modular www.agilent.com/find/pxi-switch For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden Switzerland United Kingdom 43 (0) 1 360 277 1571 32 (0) 2 404 93 40 45 45 80 12 15 358 (0) 10 855 2100 0825 010 700* *0.125 €/minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 0800 80 53 53 44 (0) 118 927 6201 For other unlisted Countries: www.agilent.com/find/contactus Revised: January 6, 2012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2012:02:17 12:31:30-08:00 Creator Tool : Adobe InDesign CS5 (7.0) Modify Date : 2012:02:17 12:31:30-08:00 Format : application/pdf Title : 5990-7580_pxi-dm_2-17-12_d3a.indd Creator : jfox Document ID : uuid:cfb230ea-608f-4058-8818-be8518510ddd Instance ID : uuid:49481157-121a-4245-9e33-21a1a33600e0 Page Count : 14 Author : jfoxEXIF Metadata provided by EXIF.tools