APT_Product_Catalog_revL.indb XRS Series APT Product Catalog

User Manual: XRS Series

Open the PDF directly: View PDF PDF.
Page Count: 56

DownloadAPT_Product_Catalog_revL.indb XRS Series APT Product Catalog
Open PDF In BrowserView PDF
“Protecting the electronic world from surges”

2016
SPD PRODUCT CATALOG
Surge Protective Devices

www.aptsurge.com

|

1.800.237.4567

|

info@aptsurge.com

Table of Contents
SPD Sizing Chart .........................................................................................................................................................................................................................................5

Type 1 and Type 2 SPDs
SPDEE Series ....................................................................................................................................................................................................................................................6
SPDEE DC Series ..........................................................................................................................................................................................................................................8
TEXCS Series ................................................................................................................................................................................................................................................10
TEXDS Series ................................................................................................................................................................................................................................................12
TEXAS Series ................................................................................................................................................................................................................................................14
TEXAL Series ...............................................................................................................................................................................................................................................16
TEXBS Series .................................................................................................................................................................................................................................................18
TEXBL Series .................................................................................................................................................................................................................................................20

Type 2 SPDs
TE/HP Series (Modular) ....................................................................................................................................................................................................................22
TE/HPS Series (Modular) ..................................................................................................................................................................................................................24
TE/XGA Series (Modular) ...............................................................................................................................................................................................................26
TE/XMS Series (Non-Modular) ...................................................................................................................................................................................................28

Component Assembly SPDs (Type 1 & Type 2)
TE/XRS Series ............................................................................................................................................................................................................................................30
TE/XRL Series ...........................................................................................................................................................................................................................................32
TE/XWS Series ........................................................................................................................................................................................................................................34
TE/XWL Series ........................................................................................................................................................................................................................................36
DIN-Rail: AC Power & DC PV ...................................................................................................................................................................................................38

Specialty SPDs
S-Kit Series ...................................................................................................................................................................................................................................................40
iArrest Series .............................................................................................................................................................................................................................................42

Low Voltage Communication & Data
BNCB5kA ......................................................................................................................................................................................................................................................44
BNCA10kA ..................................................................................................................................................................................................................................................45
BNC Guide ....................................................................................................................................................................................................................................................46
DIN-Rail: Popular Traffic / ITS .......................................................................................................................................................................................................47
DIN-Rail: Low Voltage .......................................................................................................................................................................................................................48

Medium Voltage SPDs
MVF Series ...................................................................................................................................................................................................................................................50
What Electrical System is It? .....................................................................................................................................................................................................52
Frequently Asked Questions ......................................................................................................................................................................................................53
Don’t Leave your Home Unprotected .............................................................................................................................................................................54

Past,
Past,Present
Present&&Future
Future
Past, WHY
Present
&
Future
APT?

AdvancedProtection
ProtectionTechnologies,
Technologies,
Inc.
Inc.
TopTop
Notch
Notch
Customer
Customer
Service
Service
“Protecting
“Protecting the
the Advanced
Advanced
AdvancedProtection
Protection
Technologies,
Technologies,
Inc.Inc.
(APT)
(APT)
hashas
been
been APTAPT
has has
earned
earned
the respect
the respect
from our
fromclients
our clients
by providing
by providing
electronic
electronic world
world designing,
designing, manufacturing
manufacturing and
and selling
sellingIndustrial,
Industrial,world
world
classclass
customer
customer
service.
service.
Frost Frost
& Sullivan
& Sullivan
has has
Commercial,
Commercial,Oil/Gas
Oil/Gasand
andResidential
Residential
Surge
Surge
Protective
Protective honored
honored
us for
us three
for three
yearsyears
with with
awards
awards
for superior
for superior
Advanced
Protection
Technologies,
Inc.
Top
Notch
Customer
Advanced
Protection
(APT)
has
anumber
worldwide
“Protecting
from
surges“
surges“ the
Devices
Devices
(SPDs)
(SPDs)
since
since
1985.
1985.
WeWe
areare
aTechnologies,
privately
a privately
heldheldInc.
service
service
and
has
and
ranked
hasbeen
ranked
APT
APT
number
oneService
inone
the in
SPD
thethree
SPD three
company
company
with
withnono
debt
debt
that
that
has
has
been
been
under
under
thethe
original
original
phase
market.
market.
Ourearned
Our
manufacturing
manufacturing
processes
processes
ISO
are
Advanced
Protection
Technologies,
Inc.
(APT)
has phase
been
APT
has
the respect
from
ourare
clients
by ISO
providing
leader
in the
surge
suppression
industry
since
1985.
Headquartered
electronic world
ownership
ownership
for
forthe
theentire
entireduration.
duration.
What
What
began
began
as as
aIndustrial,
a 9001:2008
9001:2008
certified.
certified.
We customer
have
We have
two in-house
two in-house
testing
labs
labs has
designing,
manufacturing
and
selling
world
class
service.
Frost testing
& Sullivan
in Central
Florida,
heart
oftolightning
activity,
APT’s
surge
protection
small
smallcompany
companyofoften
ten
employees,
employees,
selling
selling
to customers
customers
thatthat
are ISO
are
ISO
17025
17025
certified
certified
by ULby
toUL
do to
portions
do awards
portions
of UL for
of UL
Commercial,
Oil/Gas
and Residential
Surge
Protective
honored
us
for
three
years
with
superior
from surges“
products
have
long
set
theaa global
standard
for
protection
of ranked
commercial
inin Southeastern
Southeastern
USA,
USA,has
hasgrown
grown
to to
become
become
a global 1449
1449
testing.
testing.
Devices
(SPDs)
since
1985.
We
are
privately
held
service and has
APT number one in the SPD three

industry
industry
leader
leader
with
with
over
over
one
one
hundred
hundred
employees.
employees.
company
with
no
debt
that
has
been
under
the original
phase market. Our manufacturing processes are ISO
and industrial
facilities.
Each
Each member
memberofoffor
the
the
senior
senior
management
management
team
team
has
has Local
ownership
the
entire
duration. What
began
as Local
a Growth
9001:2008
We have
two
in-house testing labs
Growth
&certified.
Worldwide
& Worldwide
Presence
Presence
been
beenwith
withthe
the
company
company
for
more
more
than
than
15selling
15
years.
years.
APT
APT
small
company
of for
ten
employees,
to
customers
that are ISO 17025 certified by UL to do portions of UL
In 2007,
In 2007
APT’s
, APT’s
growth
growth
strategy
strategy
expanded
expanded
from its
from
base
itsinbase in
In
addition
to superior
products,
APT
has
received
numerous
awards
has
has eight
eight
degreed
degreed
Electrical
Electrical
Engineers
Engineers
on
staff,
staff,
an
in Southeastern
USA,
has
grown
to on
become
aanglobal
1449 testing.
the the
US US
Construction
Construction
Market
Market
and began
and began
to focus
to focus
on
on
exceptionally
exceptionally
trained
technical
sales
team
team
andthe
and
a coveted
a
industry
leader technical
with
oversales
one
hundred
employees.
for trained
customer
service
including
Frost
and
Sullivan
Market
Alternative
Alternative
Energy,
Energy,
Oil/Gas,
Oil/Gas,
OEM
OEM
and International
and International
manufacturing
manufacturing
team
teamtrained
trained
in
thethe
latest,
latest,
state
state
of the
ofteam
the has
Each member
of
thein senior
management
Local
&keyWorldwide
Presence
Markets.
Markets.
APT APT
hasGrowth
has
developed
developed
relationships
key relationships
and a and a
Engineering
Award.
art,
art,Lean
Lean
manufacturing
manufacturing
processes.
processes.
been
with the company
for more than 15 years. APT
number
number
ofInnew
of new
products
products
that will
that
drive
will growth
drive
growth
in these
in these
2007
, APT’s
growth
strategy
expanded
from
its base in
has eight degreed Electrical Engineers on staff, an
newnew
markets
markets
for
years
to come.
to come.
InMarket
2010,
In 2010,
APT
APT
growth
hitto focus
hit on
the for
USyears
Construction
andgrowth
began
trained technical sales team and a
Our commitment
to service and exceeding
expectations
comes
41%41%
overover
the previous
the
previous
year. year.
Following
Following
that OEM
trend,
that trend,
inand
2011in
2011
Alternative
Energy,
Oil/Gas,
International
Surge
Surgeexceptionally
Protective
Protective
Devices
Devices
manufacturing team trained in the latest, state of the
we we
celebrated
celebrated
a 10,000
a 10,000
square
foot manufacturing
foot
floor floorand a
Markets.
APT
has square
developed
key relationships
from
our
people
and
sophisticated
system
integration.
We
value
themanufacturing
APT
APThas
has
the
the
most
most
complete
complete
line
line
of
of
Low
Low
Voltage
Voltage
SPDs
SPDs
in in
art,
Lean
manufacturing
processes.
expansion.
expansion.
Several
Several
new
new
positions
positions
were
were
created
created
ranging
ranging
number
of
new
products
that
will
drive
growth
in these
the
the industry,
industry,
with
with
over
over70,000
70,000
SKUs,
SKUs,
used
used
in integrity, responsiveness and
client
relationship
and
support
itinwith
frontfront
officeoffice
administration
administration
to production
production
assemblers
assemblers
new
markets
for years
to to
come.
In
2010,
APT growth hit
applications
applicationssuch
suchasasIndustrial,
Industrial,
Commercial,
Commercial,
Residential,
Residential, fromfrom
to high
level
level
manufacturing
manufacturing
personnel.
personnel.
We have
We settled
have
settled
41%
over
the previous
year. Following
that trend,
in 2011
technical
excellence.
Surge
Protective
Devices
Data/Communications
Data/Communications
and
and
much
much
more.
more.
OurOur
lowlow
voltage
voltage to high
into
into
our
our
new
new
facility
facility
and
implemented
and
implemented
new
workflow
new
workflow
we
celebrated
a
10,000
square
foot
manufacturing
floor
products
products
protect
systems
ranging
ranging
5VDC
5VDC
to SPDs
to
APTprotect
has
the systems
most
complete
linefrom
offrom
Low
Voltage
in
processes.
processes.
Expansion
Expansion
continues
continues
as
a
as
number
a
number
of
new
of
new
expansion.
Several
new
positions
were
created
ranging
600VAC,
600VAC,
including
allallinternational
international
voltage
systems.
systems.
theincluding
industry,
with overvoltage
70,000
SKUs, used in
We
are, “Professionals
Serving
Professionals”
products
products
are
are
manufactured
manufactured
and and
new to
new
brand
brand
label assemblers
label
from
front
office administration
production
applications such as Industrial, Commercial, Residential,
agreements
agreements
are
finalized.
are
finalized.
to
high
level
manufacturing
personnel.
We
have
settled
Data/Communications
and
much
more.
Our
voltage
Our
Ourproducts
products
are
arethe
thenumber
number
one
one
specified
specified
SPD
SPD
by low
oil
by oil
into
our
new
facility
and
implemented
new
workflow
products
protect
systems
ranging
from 5VDC to
producers
producers
and
and oil
oilservices
services
companies
companies
worldwide.
worldwide.
processes.
Expansion
as supplier
aone
number
of new
We We
are committed
are
committed
to becoming
to becoming
thecontinues
number
the number
one
supplier
600VAC,
including
all international
voltage
systems.
APT’s
APT’snew
new(1000VAC
(1000VAC
- 4160VAC)
- 4160VAC)
Medium
Medium
Voltage
Voltage
SPD,
SPD,of three
products
are
manufactured
and
new
brand label
of three
phase
phase
SPDsSPDs
to the
to International
the International
marketplace.
marketplace.
the
thefirst
firstofofitsitskind
kindininthe
theSPD
SPD
industry,
industry,
is commonly
is commonly APT’s
agreements
areof
finalized.
APT’s
dedicated
dedicated
network
network
distributors
of distributors
and agents
and agents
are are
used
used Our
toto protect
protect medium
medium
voltage
voltage
motors
motors
at at
oil
oil currently
products
are
the number
one
specified
SPD
by oil
currently
promoting
promoting
our products
our products
throughout
throughout
Canada,
Canada,
production
production
wells,
wells,
refineries,
water/wastewater
producers
and refineries,
oil
serviceswater/wastewater
companies
worldwide.
Mexico,
Mexico,
Central
America,
South
South
America,
America,
Asia,
Africa
Asia, one
Africa
We Central
are America,
committed
to becoming
the
number
supplier
treatment
treatment
plants
and
andmining
mining
operations.
operations.
There
There
are are and
APT’splants
new (1000VAC
- 4160VAC)
Medium
Voltage
SPD,
and
the the
Middle
Middle
East.
East.
Our
Our
proven
track
track
recordrecord
andmarketplace.
and
of
three
phase
SPDs
toproven
the
International
currently
currently
noother
other
listed
listed
Medium
Medium
Voltage
Voltage
SPDs
the no
first
of itsULUL
kind
in the
SPD industry,
is SPDs
commonly
commitment
commitment
to dedicated
a to
long
a long
term
term
business
business
philosophy
philosophy
has
has are
APT’s
network
of distributors
and agents
available
available
ininthe
the
industry.
used
toindustry.
protect medium voltage motors atpushed
oil
pushed
uscurrently
tousthe
to forefront
the
forefront
of Surge
of products
Surge
Protective
Protective
DeviceDevice
promoting
our
throughout
Canada,
production
wells, refineries, water/wastewater
manufacturing
manufacturing
and distribution.
and distribution.
Mexico,
Central
America, South America, Asia, Africa
and mining operations. There are
and the Middle East. Our proven track record and
Live
Livetreatment
Training
Trainingplants
- -Earn
Earn
PDHs
PDHs
&&
CEUs
CEUs
currently no other UL listed Medium Voltage SPDs
commitment to a long term business philosophy has
For
Forover
over
twenty
twentyyears,
APT
has
hasoffered
offered
IEEE
IEEE
accredited
accredited Private
Private
Labeling
Labeling
& Marketing
& Marketing
available
inyears,
the APT
industry.
pushed us to the forefront of Surge Protective Device
Engineering
Engineering Seminars
Seminarswhere
wherePDHs
PDHs(qualified
(qualified
andand APTAPT
is the
ismanufacturing
industry’s
the industry’s
largest
largest
private
label manufacturer
label manufacturer
and private
distribution.
approved
approvedbybyIEEE)
IEEE)can
canbebeearned
earned
that
that
areare
recognized
recognized of SPDs.
of
SPDs.
Past
Past
and
present
and
present
brand
brand
label
partners
label
partners
includeinclude
Live Training
-states,
Earn
PDHs
&
CEUs
and
and accepted
accepted
bybymost
moststates,
including
including
thethe
rigorous
rigorous Siemens
Siemens
Industry,
Industry,
Schneider
Schneider
Electric
Electric
& Square
& Square
D and D and
For
over twenty
years,
APT
has
offered
IEEE
accredited
states,
states,
Florida
Florida
and
andNew
New
York.
York.
This
This
course
course
starts
starts
with
with American
Private
Labeling
&(APC).
Marketing
American
Power
Power
Conversion
Conversion
(APC).
We regularly
We regularly
sell sell
Seminars
where topics
PDHs
(qualified
and
basics
basicsEngineering
and
andproceeds
proceeds
through
through
advanced
advanced
topics
including
including APT
APT
labeled
labeled
products
to other
to other
industry
industry
leaders
leaders
such
such
as
APT
is products
the industry’s
largest
private
labelas
manufacturer
approved
byand
IEEE)
can
be earned that
are
recognized
UL,
UL, IEEE
IEEE
&&NEC
NEC
andis isstandards-based,
standards-based,
notnot
salessalesEaton,
Eaton,
GE,
ABB,
ABB,
Rockwell
aand
number
a number
of
smaller
of smaller
ofGE,
SPDs.
PastRockwell
andand
present
brand
label
partners
include
and This
accepted
most
states,
rigorous
oriented.
oriented.
This may
mayby
bebe
thethe
most
mostincluding
efficient
efficientthe
andand
niche
niche
market
market
leaders.
leaders.
Siemens
Industry, Schneider Electric & Square D and
states, Florida
New
York.
This
course
starts with
comprehensive
comprehensive
seven
sevenand
hours
hours
of of
SPD
SPD
training
training
available.
available.
American Power Conversion (APC). We regularly sell
basics
and proceeds
through of
advanced
topics
Engineers
Engineers
appreciate
appreciate
the
the
explanation
explanation
the
of the
science,
science,
art including
art
APT labeled products to other industry leaders such as
UL, IEEE
& NEC and
issurge
standards-based,
not salesand
andmarketing
marketing
surrounding
surrounding
thethe
surge
industry.
industry.
Advanced
Advanced Protection
Protection
Eaton, GE, ABB, Rockwell and a number of smaller
oriented. This may be the most efficient and
Technologies
Technologies
niche market leaders.
comprehensive seven hours of SPD training available.
14550
14550 58th
58th Street North
North
Engineers appreciate the explanation of the science, art
Clearwater,
Clearwater, FL 33760
33760
and marketing surrounding the surge industry.
Advanced Protection

WHAT MARKETS DO
WE SERVE?

Construction
Industrial/Commercial
OEM
International

Phone:
Phone: 727.535.6339
727.535.6339
Technologies
Fax:
Fax:
14550
727.539.8955
727.539.8955
58th Street North
Clearwater, FL 33760
www.aptsurge.com
www.aptsurge.com
Phone: 727.535.6339
Fax: 727.539.8955

ITS/DOT
Specialty Sales
Medium Voltage
Residential

SPD Sizing Chart

XAS

XDS

XCS

SPDEE

Service Entrance Greater than 2000A
Exposure Level

kA per phase
Model

High Exposure

Medium Exposure

Low Exposure

Lowest Exposure

300 kA

200 kA

150 kA

100 kA

XAS30

XAS20

XAS15

XDS10

Service Entrance 1200A - 2000A
Exposure Level

kA per phase
Model

High Exposure

Medium Exposure

Low Exposure

Lowest Exposure

250 kA

200 kA

150 kA

100 kA

XAS25

XAS20

XDS15

XCS10

Service Entrance 800A - 1200A
Exposure Level

kA per phase
Model

High Exposure

Medium Exposure

Low Exposure

Lowest Exposure

200 kA

150 kA

100 kA

50 kA

XDS20

XDS15

XCS10

SPDEE

Distribution/Branch Panel 800A - 1200A
Exposure Level
kA per phase

Model

High Exposure

Medium Exposure

Low Exposure

Lowest Exposure

200 kA

150 kA

100 kA

50 kA

XDS20

XDS15

XCS10

SPDEE

Distribution/Branch Panel Less than 800A
Exposure Level

kA per phase
Model

High Exposure

Medium Exposure

Low Exposure

Lowest Exposure

150 kA

100 kA

100 kA

50 kA

XDS15

XDS10

XCS10

SPDEE

PRICING & PRODUCT INFORMATION
Call 800.237.4567 or visit www.aptsurge.com

spee- dee
Type 1 / Type 2 Surge Protective Device/SPD
Features:
• UL 1449 Fourth Edition Listed
• 50kA 8 x 20 µs
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 200kA SCCR (most models)
• All UL-required OCP & Safety Coordination Included Inside
• Voltage Specific Design: Performs better than ‘one-size fits all’
• Tri-Mount Installation for more mounting flexibility:
– Same unit mounts on Pipe Nipple, Bracket or DIN-Rail
• Visual Diagnostics: Easy to See; Easy to Understand

Performance Specifications

Green=Go Visual Diagnostic Monitoring

•
•
•
•
•
•

50kA 8 x 20µs Per Mode
• Green LED = A-OK, Out = replace
UL 1449 tested Inominal: 20kA (highest available)
• LED Visible from Multiple Sides & Angles - Better Viewing
UL 1449 tested SCCR: 200kA (most models)
• Every MOV is Monitored as opposed to ‘power is present’
Large-Block, 34mm square, 50kA MOVs
Individually Fused & Thermally Protected MOVs
Tri-Mount Installation
UL 1449 Voltage Protection Ratings (VPRs):
– 600V for 120V, 120/240, 208Y/120
– 1000V for 277V, 480Y/277V
• Repetitive Impulse: 5000 - 3kA - 8 x 20µs; 1000 - 10kA - 8 x 20µs
• Data table on backpage
Std. 3/4”-14
Nipple

Physical Specifications
•
•
•
•
•
•
•
•
•

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47 - 63Hz
Peak Operating Temperature: +85oC (185oF)
Typical Operating Temperature: -40oC (-40oF) to +60oC (140oF)
Response Time: < 1nanosecond
Solid State Bi-directional Operation
NEMA 4X Polycarbonate Enclosure—UL746C(f1), UL 94-5VA
Pre-wired with 3’ (1m) of #10 AWG conductor
Typical Type 2 Connection: #10 AWG to 30A breaker

Dimensions

3.25
[82.55]

3/4” - 14

4.12
[104.66]

3.58
[90.97]

3.38
[85.95]

3.30
[83.74]

3.24
[82.20]
1.26
[32.05]

1.15
[29.21]

Weight:1.60 lbs (0.73 kg)
Sized for std 35mm Din-Rail

•
•
•
•

N-G protection
Dry Contact & Audible Alarm
Dry Contact connection leads exit through nipple via #18 AWG
Other configurations available for OEM - Call

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•
•
•

2 year warranty (longer optional)
UL 1449 4th Edition file: VZCA.E321351 at www.UL.com, cUL
Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Edition, CSA 22.2 No. 269.2
ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
NEMA LS-1
IEC 61643, CE
Burn-In tested prior to shipment
ISO 9001:2008 Certified Quality Management System
ISO 17025:2005 Certified Test Lab
RoHS-compliant

Special Thank You to NASA/SATOP for design assistance & validation

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Bracket Mount
for flat surfaces

Options

Advanced Protection Technologies
6

DIN-Rail Mount
(rail not incl.)

Application Guide

MODEL NUMBER CONFIGURATOR & OPTIONS

50

A
(Default)

Surge Current
Rating

Voltage

System

120V

50 = 50kA/Phase

127V

1P = One Pole,
Single Phase

N = N-G
Protection

2P = Two Pole,
Split Phase

D = Dry Contact
& Audible
Alarm

220V

EXAMPLES:

240V

S50A120V3Y

277V

50kA, 120V, 3 pole
(208Y/120V)

347V
480V

S50A277V3YN

50kA, 277V, 3 pole
(480Y/277V) with N-G

600V

3Y = Three Pole
Wye

2 = Type 2 SPD,
including
CSA 22.2,
No. 269.2

3D = Three Pole
Delta
3H = Three Pole
Hi-Leg Delta

No cost accessories:

8483 Supplementary label

SYSTEM
CONFIGURATION

Options

}

1 POLE / SINGLE

S

N-G*

MCOV

L-G*

S50A120V1P
S50A120V2P
S50A120V3Y
S50A127V1P
S50A127V2P
S50A127V3Y
S50A220V1P
S50A220V3Y

120V
600
600* 1000* 20kA
120V/240V 600 1000 600* 1000* 20kA
208Y/120V 600 1000 600* 1000* 20kA
127V
700
600* 1200* 20kA
127/254V
700 1200 600* 1200* 20kA
220Y/127V 700 1200 600* 1200* 20kA
220V-1 pole 1200
1000* 1800* 20kA
380Y/220V 1200 2000 1000* 1800* 20kA
- 600 1000
1000*
S50A240V3H 120/240V
Hi-Leg Delta /1200 /1500 600* /1500* 20kA
S50A240V1P 240V-1 pole 1200
1000 1800
20kA
Delta S50A240V3D 240V
1500
1200
20kA
3 pole
S50A277V1P 277V
1200
1000* 1800* 20kA
S50A277V2P 240/480V
1200 2000 1000* 1800* 20kA
S50A277V3Y 480Y/277V 1200 2000 1000* 1800* 20kA
S50A347V3Y 600Y/347V 1500 2500 1200* 2500* 20kA
S50A480V1P 480V-1 pole
1800
20kA
480V
Delta
S50A480V3D 3 pole
3000
1800
20kA
- 1200/
S50A480V3H 240/480V
20kA
Hi-Leg Delta 1800 2500
600V
Delta
S50A600V3D 3 pole
2500
2500
20kA
S100A120V2P 120/240V
600 1000
600
20kA
S100A277V2P 240/480V
1000 1800
1000
20kA
* with optional N-G protection

200kA
200kA
200kA
100kA
100kA
100kA
200kA
200kA

150
150
150
180
180
180
320
320

2 POLE / SPLIT

L-L

SCCR

}v
}v

Neutral (WHT)

320
320
320
420
550

BLK

WHT

WHT
Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

Model Number

BLK

Hot (BLK)
Neutral (WHT)

WHT
BLK

WHT
BLK
Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

Model Number

BLK

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

GRN

Model Number

BLK

B Phase B (BLK)
BLK

BLK

Neutral (WHT)

N

WHT
WHT

v
Hot (BLK)
Ground (GRN)

C

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

BLK

BLK

GRN

Voltage

Model Number

Model Number

200kA 320 / 550
Phase A (BLK)
Phase B (ORNG)

200kA 690
100kA 150
100kA 320

v

BLK

BLK

ORNG

Hot (BLK)
Neutral (WHT)
Ground (GRN)

ORNG
BLK

BLK
Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

WHT

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

WHT
GRN

Model Number

Voltage

Model Number

S50A240V3H

Form C Dry Contact:

N/A
Dry
Contact
Leads

Use Gray & Blue

• Normally Closed:
Use Gray & Red

Audible Alarm:
Alarm sounds when any protection
is lost (If diagnostic LED extinguishes
(i.e. problem), alarm will sound)

v
DELTA

Power
Leads

• Normally Open:

10.16.17.lh.RevH # 8179

Model Number

200kA 550

Optional Form C Dry Contact & Audible Alarm
Three (3) #18 wires
exit the pipe nipple
Gray is Common,
Blue is Normally
Open, Red is
Normally Closed

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

GRN

BLK

Phase A (BLK)

A

200kA 320
200kA
200kA
200kA
200kA
200kA

BLK

Voltage

200kA 150 / 320
200kA 320

Downstream of N-G
Bond - N-G protection
suggested

Hot (BLK)
Ground (GRN)

WYE

L-N

In

N-G Bonded - Does not
require N-G protection

Voltage

HI-LEG

UL 1449 Fourth Edition
Voltage Protection Rating
VPR 3000A

System
Voltage &
Config

INSTALLED >10’(3M)
FROM SERVICE
ENTRANCE OR
TRANSFORMER

Ground (GRN)

Performance Data
MODEL

Hot (BLK)

v

INSTALLED AT OR
NEAR SERVICE
ENTRANCE OR
TRANSFORMER

Phase A (BLK)

BLK

Phase B (BLK)
Phase C (BLK)
Ground (GRN)

BLK

Voltage

Corner Grounded
Delta?

BLK
GRN

Advanced Protection Technologies
14550 58th St. N.
Clearwater, FL 33760
800.237.4567 X www.aptspd.com

Model Number
S50A240V3D

Use same models
& connect one SPD
black & green to
ground (diagnostics
will function correctly)

Red
Blue

Gray

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

7

DC

SPDEE

Go Green with APT

DC Voltage Surge Protective Device

UL Listed to UL 1449 Photovoltaic Standard
(VZCA.E321351 & VZCA7.E321351)

• UL Listed as opposed to Recognized - avoids scrutiny over
Technical Considerations of Recognized products
• Avoids Certification Surprises
• No Unexpected Installation Requirements

Listed to UL 1449 as DC SPD for use in PV applications
Options & Configurations for OEMs (see back)
Does not require additional upstream fusing for SPD safety protection
• 100kA DC Short Circuit Current Rating (SCCR)
• Fail-Safe operation – arc breaking, slide-gate thermal disconnectors built-in
• Avoids safety challenges and fusing shortcomings of overseas-standard SPDs

Performance Specifications
•
•
•
•
•
•
•
•
•
•
•

50kA 8x20µs Per Mode
300VDC, 600VDC, 1000VDC, 1500VDC & OEM models
All modes of protection: DC+ – G, DC- – G, DC+ – DCUL 1449 tested In: 20kA (1500V: 10kA)
UL 1449 tested SCCR: 100kA DC
UL 1449 Listed as Type 1 SPD
UL 1449 Type 2 optional for cUL Mark
Large-Block arrestor-grade 34mm square MOVs
Individually Fused and Thermally Protected MOVs
Repetitive Impulse: 5000 - 3kA-8 x 20µs; 1000 - 10kA-8 x 20µs
Response Time: < 1nanosecond

Physical Specifications
• Relative Humidity Range: 0 - 95% non-condensing
• Operating Frequency: DC
• Operating Temperature: -40˚C (-40˚F) to +65˚C (149˚F)
(1500VDC: -40˚C (-40˚F) to +85˚C (185˚F))
• Solid State Bi-directional Operation
• NEMA 4X Polycarbonate Enclosure – UL746C(f1), UL 94-5VA
• Pre-wired with 3’ (1m) of #8 AWG & #6 AWG ground conductor
(1500VDC: #10 AWG)

Tri-Mount Installation - Mounting Kit Included

Monitoring Configurations
• Standard - Low consumption LED; monitors every MOV
– Illuminates when power is produced
• Options
– R - Removes LED and its circuitry
– M - MOV Microswitch access option (requires R above)

Dimensions

4.13”
Weight: 1.60 lbs
(0.73 kg)

3.26”

3.31”

3.26”

3.57”

3/4”-14

Std. 3/4”-14
Nipple

•
•
•
•
•
•
•

2 year warranty (longer optional)
ANSI/IEEE C62.41.1-2002, C62.41.2-2002 & C62.45-2002
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025: Certified Test Lab
IEC 61643, CE
UL 96A Lightning Protection Master Label Eligible @ 20kA In

Sized for std 35mm DIN-Rail

Advanced Protection Technologies
8

Bracket Mount
for flat surfaces

Quality, Standards & Validation

1.15”

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

DIN-Rail Mount
(rail not included)

DC

SPDEE

DC Voltage Surge Protective Device

Applications & Models
UL 1449 Model Number
DC Voltage
Maximum Continuous Operating Voltage (Vpvdc)
Voltage Protection Level (Up) @ 6kV/3kA

S50A300VDC

S50A600VDC

S50A1000VDC

S50A1500VDC

0-300VDC

0-600VDC

0-1000VDC

0-1500VDC

424VDC

905VDC

1188VDC

1500VDC

<1000Vp

<2000Vp

<2500Vp

<3000Vp

SPDEE DC Model Number Configurator & Options
UL 1449

S50A

Voltage

50kA default

300VDC
600VDC
1000VDC
1500VDC

Examples:
- S50A300VDCRM = 50kA, 300VDC, Remove LED,
Microswitch Monitoring
- S50A1000VDC2 = 50kA, 1000VDC, Type 2 marking for Canada

Options
2

= Type 2 SPD bearing cULus Mark (for Canada).

R

= Removes LED and its circuitry Visual Monitoring
via pop-up indicator tabs on each MOV.

M

= Microswitch option - requires R option above.
Allows remote access to logic connected MOV
diagnostics. Includes 20 AWG wires out of nipple.
Power must be limited to 50mA at 12VDC.

G

= For Grounding DC+ terminal of system (call).

Schematic: All Modes of Protection
DC+
red wire

DC —
black wire

Available Z Mounting
Bracket Accessory

AC Voltage SPDEE’s
Also Available

GROUND
green/yellow wire

OEM & Brand Label Opportunities
Please call 800.237.4567

9.16.15.lh.RevJ #8383

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

9

Type 1/Type 2 Surge Protective Device/SPD
Features

• UL 1449 Fourth Edition Listed
• 100kA per phase rating
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – highly configurable
• All MOV suppression elements monitored
• All Modes of Protection

Performance Specifications

Design Features

Surge Capacities

L-N

L-G

N-G

L-L

100kA Per Phase

50kA

50kA

50kA

100kA

•
•
•
•
•
•

UL 1449 Fourth Edition Listed
UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
Optional UL 1449-4 Type 2 SPD, CSA 22.2 No. 269.2
UL 1449-4 tested Inominal (In): 20kA
UL 1449-4 tested SCCR: 200kA & 100kA
UL 1449-4 Voltage Protection Ratings (VPRs)
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V (data table on back)
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits

Physical Specifications
•
•
•
•
•
•
•
•
•

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47 - 63Hz (also 400Hz on <480V)
Operating Temperature: -40°C (-40°F) to +85°C (185°F)
Weight: 3 lbs (1.4 kg)
NEMA 4X Polycarbonate enclosure – UL 746C(f1) & UL 94-5VA
Dimensions: 8.3” x 3.6” x 3.0” (211mm x 91mm x 77mm)
3/4” threaded hub - weather resistant 4X
Pre-wired with 3’ (1m) of #10 AWG conductor
Typical connection: #10 AWG and 30A breaker

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 & C-High
applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Solid State Bidirectional Operation

Diagnostic Monitoring
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
• Optional: Audible Alarm & Form C Dry Contact (Contact rated
240V, 5A; leads are pre-wired through nipple with #18 AWG)

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
10

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Edition, CSA No. 269.2
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXCS

MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

XCS

ll

l...

Voltage Code for Electrical System

Surge Current Rating

Options

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
08 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

10 = 100kA/Phase

A

= Audible Alarm & Dry Contacts
Form C, 240V, 5A (pre-wired)

E

= Remote Indicator LED on 6’ Cable
(pre-wired through nipple)

2

= Type 2 SPD

Standard Enclosure Rating

Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)

Figure 1
}V
}V

Figure 2
Phase A (BLK)

Hot (BLK)

B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)

N

Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

C

}

V

Figure 4

Phase A (BLK)
Phase B (ORNG)

}

}

V

V

Phase C (BLK)

Ground (GRN)

HI-LEG DELTA (B
High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

WYE
3 Hots, 1 Neu, 1 Grnd

Available Accessory (order separately)
XMFMKIT = Flush Mount Kit
RM = Remote Monitor

Figure 3

Neutral (WHT)

Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)

NEMA 4X Polycarbonate
(size 8.3” x 3.6” x 3.0”)

Ground (GRN)

DELTA & HRG WYE
3 Hots, 1 Grnd

}

Figure 6

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye
480V 3� Delta
600Y/347V 3� Wye

L-N

L-G

N-G

L-L

In

SCCR

MCOV

600
600
600/1200
1200
1500

700
700
700/1200
1200
1800
1500

500
500
500
1000
1500

1000
1000
1000
1800
1800
2500

20kA
20kA
20kA
20kA
20kA
20kA

100kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
552
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

10.16.17.lh.RevH #8389

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

11

Type 1/Type 2 Surge Protective Device/SPD
Features:

• UL 1449 Fourth Edition Listed
• 100kA – 200kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection

Performance Specifications
Surge Capacities

L-N

L-G

N-G

L-L

100kA Per Phase

50kA

50kA

50kA

100kA

150kA Per Phase

100kA

50kA

50kA

150kA

200kA Per Phase

100kA

100kA

100kA

200kA

• UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed,
CSA 22.2 No. 269.2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V (data table on back)
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to
-50dB from 10kHz to 100MHz (Type 2 option only, incl.
UL 1283 Listing)

Physical Specifications
•
•
•
•
•
•
•

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47 - 63Hz
Peak Operating Temperature: +85°C (185°F)
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 5 lbs (2.3 kg)
NEMA 4X Polycarbonate enclosure – UL 746C(f1) & UL 94-5VA
Dimensions: 6” x 6” x 4” (152mm x 152mm x 102mm)
(excluding removable mounting feet)
• Lug size: #8 - #10 AWG
• Typical connection: #8 AWG and 40A breaker

Advanced Protection Technologies
12

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 & C-High
applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Solid State Bidirectional Operation

Diagnostic Monitoring
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Phase Loss monitoring (toggles LED & dry contact)
Electrically isolated circuitry ensures surges do not damage
diagnostics
• Optional: Audible Alarm & Form C Dry Contact
(Contact rated 240V, 5A)

Quality, Standards & Validation
• Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
• Type 2 (Opt.): UL 1449 Fourth Edition, CSA No. 269.2,
UL 1283
• UL file: VZCA.E321351 at www.UL.com
• RoHS-compliant
• IEC 61643, CE
• 10 year warranty (longer optional)
• Burn-In tested prior to shipment
• ISO 9001:2008 Quality Management System
• ISO 17025:2005 Laboratory Qualification

TEXDS

MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XDS

l...

4X

Voltage Code for Electrical System

Surge Current Rating

Options

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
08 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

10 = 100kA/Phase
15 = 150kA/Phase
20 = 200kA/Phase

A = Audible Alarm & Dry Contacts,
Form C, 240V, 5A
2

Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
Enclosure Rating
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
4X = NEMA 4X
Non-Metallic
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(size 6” x 6”x 4”)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
(Available: 100kA)
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(Available: 100kA)
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)

Figure 1
}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)

N

Ground (GRN)

C

}

Figure 3

V

}

}

V

V

Neutral (WHT)

Phase C (BLK)

Ground (GRN)

Figure 5

}

Phase A (BLK)
Phase B (BLK)

}V

Hot (BLK)

Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

HI-LEG DELTA (B High) DELTA & HRG Wye
SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd 3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Figure 6

V

Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

Available Accessory (order separately)
KITFMXF = Flush Mount Kit
RM = Remote Monitor

Figure 4

Phase A (BLK)
Phase B (ORNG)

= Type 2 SPD, incl. UL 1283 EMI/RFI Filters

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye
480V 3Ø Delta
600Y/347V 3Ø Wye

L-N

L-G

N-G

L-L

700
700
700/1200
1200
1500

700
700
700/1200
1200
1800
1500

600
600
600
1200
1500

1000
1000
1000/2000
2000
2000
2500

In

20kA
20kA
20kA
20kA
20kA
20kA

SCCR

MCOV

100kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

10.16.17.lh revH #8390

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

13

Type 1/Type 2 Surge Protective Device/SPD
Features:

• UL 1449 Fourth Edition Listed
• 100kA – 500kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection
• Optional Rotary Disconnect Switch

Performance Specifications
Surge Capacities

L-N

L-G

N-G

L-L

100kA Per Phase

50kA

50kA

50kA

100kA

150kA Per Phase

100kA

50kA

50kA

150kA

200kA Per Phase

100kA

100kA

100kA

200kA

250kA Per Phase

150kA

100kA

100kA

250kA

300kA Per Phase

150kA

150kA

150kA

300kA

400kA Per Phase

200kA

200kA

200kA

400kA

500kA Per Phase

250kA

250kA

250kA

500kA

• UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed, CSA 22.2
No. 269.2
• UL 1449-4 tested Inominal: 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz (Type 2 option only, incl. UL 1283 Listing)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm & Dry
Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance Eprom memory

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002, C62.62-2010
and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High applications
• For External Mounting next to Switchgear, Motor Controls Centers or
Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
14

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 24 lbs (11 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 12” x 12” x 7” (305mm x 305mm x 177mm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Edition, CSA No. 269.2, UL 1283
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXAS

MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XAS

ll

l...

Voltage Code for Electrical System

Surge Current Rating

Options

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
(450kA replaces 400kA or 500kA)
08 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

10
15
20
25
30
40
45

X

=
=
=
=
=
=
=

100kA/Phase
150kA/Phase
200kA/Phase
250kA/Phase
300kA/Phase
400kA/Phase
450kA/Phase

E
F

(Voltage Codes 05, 51, 06 & 61)

= Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup
= Remote Locatable Display on 4 ft Cable
custom cable lengths available
= Noise Filtering - Extended Range &
Attenuation (available on 400kA & 500kA
models)
= Rotary Disconnect Switch, ABB, UL98

D
Other Available Systems - Confirmation encouraged: 50 = 500kA/Phase
T = Thru-Door Rotary Disconnect Switch,
15 = 254/127V Split Phase - 1� 3W+Grnd (Fig 1)
ABB, UL98, E1 enclosure only
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
(Consult factory for other disconnect
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
switch options)
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
Delete Options - Consult Factory for Order Code
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
Delete L-N Protection (reduces kA rating)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
Delete L-G Protection (reduces kA rating)
(450kA replaces 400kA or 500kA)
Delete N-G Protection (reduces kA rating)
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
Delete Noise Filtering
(450kA replaces 400kA or 500kA)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
Available Accessory (order separately)
(450kA replaces 400kA or 500kA)
RM = Remote Monitor
380Y/220V
Wye
3�
4W+Grnd
(Fig
2)
07 =
Enclosure Rating
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
(Available: 100kA, 150kA, 200kA, 250kA)
E1 = NEMA 1/12/3R/4 (size: 12” x 12” x 7”)
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
4X = NEMA 4X Non-Metallic (size: 14” x 12”x 6”)
(Available: 100kA, 150kA, 200kA, 250kA)
(polycarbonate, display inside clear front door)
11 = 120V Single Phase (Fig 5)
4S = NEMA 4X Stainless Steel (size: 12" x 12"x 6")
12 = 240V Single Phase (Fig 5) - Not split phase
(display inside door)
13 = 127V Single Phase (Fig 5)
FM
=
NEMA
1 Flush Mount (wall cavity size: 12” x 12”x 6” deep)
14 = 300V Single Phase (Fig 5)
P1 = NEMA 1 pullbox ‘indoor’ (size: 12” x 12” x 6”) includes ‘E’ option
16 = 277V Single Phase (Fig 5)
(Optional rotary disconnect increases enclosure sizes to 16” x 14” x 6” on models > 300kA)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)

Figure 1

}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)

N

Ground (GRN)

C

}

Figure 3

}

}

V

V

Neutral (WHT)
V

Figure 4

Phase A (BLK)
Phase B (ORNG)
Phase C (BLK)

Ground (GRN)

}

Figure 6

}V

Hot (BLK)

V

Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

Figure 5
Phase A (BLK)

Ground (GRN)

Neutral (WHT)

Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

SPLIT
WYE
HI-LEG DELTA (B High) DELTA & HRG WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd 3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Phase A (BLK)

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
01
02
02
03
04
04
05
07
08

=
=
=
=
=
=
=
=
=
=

240/120V Split Phase (<300kA)
240/120V Split Phase (=>300kA)
208Y/120V 3� Wye (<300kA)
208Y/120V 3� Wye (=>300kA)
240Y/120V B High Leg Delta
480Y/277V 3� Wye (<300kA)
480Y/277V 3� Wye (=>300kA)
480V 3� Delta (<300kA)
380Y/220V 3� Wye (<300kA)
600Y/347V 3� Wye (<300kA)

L-N

L-G

N-G

L-L

In

SCCR

MCOV

700
700
700
700
700/1200
1200
1200
1200
1500

700
600
700
600
700/1200
1200
1000
1800
1200
1500

700
600
700
600
700
1200
1000
1200
1500

1200
1000
1200
1000
1800
2000
1800
1800
2000
2500

20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA

100kA
100kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA

150
150
150
150
150 / 320
320
320
550
320
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect switch may increase VPRs.
10.16.17.lh revD #8386

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

15

Type 1/Type 2 Surge Protective Device/SPD
Features:

• Directly Connected, Discrete Protection Elements
Between All Possible Modes
• UL 1449 Fourth Edition Listed
• 150kA – 450kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant (@20kA In)
• All MOV suppression elements monitored
• All Modes of Protection

Performance Specifications

• Directly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode
Protection
Surge Capacities

L-N

L-G

N-G

L-L

150kA Per Phase

50kA

50kA

50kA

50kA

300kA Per Phase

100kA

100kA

100kA

100kA

450kA Per Phase

150kA

150kA

150kA

150kA

• UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed,
CSA 22.2 No. 269.2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits

• AC Sinewave True Tracking Filter with EMI/RFI Filtering
up to -50dB from 10kHz to 100MHz (Type 2 option only,
incl. UL 1283 Listing)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring
Electrically isolated diagnostic circuitry
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 & C-High
applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
16

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 24 lbs (11 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 12” x 12” x 7” (305mm x 305mm x 177mm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.2, UL 1283
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXAL

10-MODE MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XAL

Voltage Code for Electrical System

ll

Surge Current Rating

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)

15 = 150kA/Phase
30 = 300kA/Phase
45 = 450kA/Phase

03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd (Fig 1)

l...

Options
X

= Surge Counter, six-digit LCD counter
includes maintenance-free Eprom
memory backup

E

= Remote Locatable Display on 4 ft Cable
custom cable lengths available

F

= Noise Filtering - Extended Range &
Attenuation (available on 450kA & 500kA models)

D = Rotary Disconnect, ABB, UL98
T

18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)

= Thru-door Rotary Disconnect Switch,
Katko, UL 508, E1 enclosure only

(Consult factory for other disconnect switch options)

21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
2

42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)

= Type 2 SPD, incl. UL 1283 EMI/RFI Filters

43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)

Figure 1
}V
}V

Hot (BLK)

Available Accessory (order separately)
RM = Remote Monitor

Neutral (WHT)
Hot (BLK)
Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

Figure 3
Phase A (BLK)
Phase B (ORNG)

}

V

Enclosure Rating

Phase C (BLK)
Neutral (WHT)
Ground (GRN)

Figure 2

E1 = NEMA 1/12/3R/4 (size: 12” x 12” x 7”)
4X = NEMA 4X Non-Metallic (size: 14” x 12”x 6”)

Phase A (BLK)
B Phase B (BLK)

A
N

C

}

Neutral (WHT)
V

Phase C (BLK)

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

(polycarbonate, display inside clear front door)

4S = NEMA 4X Stainless Steel (size: 12" x 12"x 6")
(display inside door)

FM = NEMA 1 Flush Mount (wall cavity size: 12” x 12”x 6” deep)
P1 = NEMA 1 pullbox ‘indoor’ (size: 12” x 12” x 6”) - includes ‘E’ option

Ground (GRN)

(Optional rotary disconnect increases enclosure sizes to 16” x 14” x 6” on 450kA only)

WYE
3 Hots, 1 Neu, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04

=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye

L-N

L-G

N-G

L-L

In

SCCR

MCOV

700
700
800/1500
1200

700
700
700/1200
1200

700
700
700
1200

1000
1000
1800
1800

20kA
20kA
20kA
20kA

100kA
200kA
200kA
200kA

150
150
150 / 320
320

700
700
1200
1200
1200
1200

1000
1000
1800
1800
1800
1800

20kA
20kA
20kA
20kA
20kA
20kA

200kA
200kA
200kA
200kA
200kA
200kA

150
180
320
320
320
320

Other Available Systems - Confirmation encouraged:
15
21
42
43
44
07

=
=
=
=
=
=

254/127V Split Phase
220Y/127V 3Ø Wye
415Y/240V 3Ø Wye
400Y/230V 3Ø Wye
440Y/250V 3Ø Wye
380Y/220V 3Ø Wye

700
700
1200
1200
1200
1200

700
700
1200
1200
1200
1200

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect switch may increase VPRs.
9.29.15.lh.RevC #8385

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

17

Type 1/Type 2 Surge Protective Device/SPD
Features:

• UL 1449 Fourth Edition Listed
• 400kA – 1,000kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Rotary Disconnect Switch included as Standard Equipment
• Dual Redundant Replaceable Modules
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection

Performance Specifications

Design Features

Surge Capacities

L-N

L-G

N-G

L-L

400kA Per Phase

200kA

200kA

200kA

400kA

600kA Per Phase

300kA

300kA

300kA

600kA

800kA Per Phase

400kA

400kA

400kA

800kA

1000kA Per Phase

500kA

500kA

500kA

1000kA

• UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed,
CSA 22.2 No. 269.2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 700V
– 480Y/277V: as low as 1200V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz (Type 2 option only, incl. UL 1283 Listing)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance Eprom memory

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 & C-High applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Dual Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
18

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 52 lbs (23.6 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 20” x 20” x 7.5” (50.8cm x 50.8cm x 19cm)
Lug size: #6 - #1/0 AWG
Typical connection: #6 AWG and 60A breaker

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.2, UL 1283
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXBS

MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XBS

Voltage Code for Electrical System

ll

Surge Current Rating

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig4) & HRG Wye
(Available: 400kA, 600kA, 900kA)
08 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig2)

40

l...

Options

= 400kA/Phase

X

= Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup

(Voltage Codes 09 & 91 only)

E

60
80
90

= Remote Locatable Display on 4 ft Cable
custom cable lengths available

F

= Noise Filtering - Extended Range &
Attenuation (available on 400kA & 500kA
models)

(Voltage Codes 09 & 91 only)

50

= 500kA/Phase
= 600kA/Phase
= 800kA/Phase
= 900kA/Phase

(Voltage codes 05, 51, 06, 61 only)

T = Thru-Door Rotary Disconnect Switch, ABB,
Other Available Systems - Confirmation encouraged: 1K = 1000kA/Phase
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
UL98, E1 enclosure only
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
K = Rotary Disconnect Switch, Katko, UL508
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
S = Thru-Door Rotary Disconnect Switch,
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
Katko, UL 508, E1 enclosure only
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters
(Available: 600kA & 900kA)
Delete Options - Consult Factory for Order Code
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
Delete L-N Protection (reduces kA rating)
(Available: 600kA & 900kA)
Delete L-G Protection (reduces kA rating)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
Delete N-G Protection (reduces kA rating)
(Available: 600kA & 900kA)
Delete Noise Filtering
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
Available Accessory (order separately)
(Available: 400kA & 500kA)
RM = Remote Monitor
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
Enclosure Rating
(Available: 400kA & 500kA)
E1 = NEMA 1/12/3R/4 (size: 20”. x 20” x 7.5”)
4X = NEMA 4X Non-Metallic (size: 24” x 24”x 8”)
(fiberglass, display inside door)

4S = NEMA 4X Stainless Steel (size: 20" x 20"x 7")
(display inside door)

P1 = NEMA 1 pullbox ‘indoor’ (size: 20” x 20” x 6”) - includes ‘E’ option
FM = NEMA 1 Flush Mount (wall cavity size: 20” x 20”x 6” deep)
(Dimensions include standard rotary disconnect switch. Optional Thru-Door
handle does not increase enclosure sizes.)

Figure 1
Hot (BLK)

}V
}V

Figure 2

Neutral (WHT)

B Phase B (BLK)
N

Hot (BLK)
Ground (GRN)

C

}

}

}

V

V

Neutral (WHT)
V

Figure 4

Phase A (BLK)
Phase B (ORNG)

Phase A (BLK)
A

SPLIT
2 Hots, 1 Neu, 1 Grnd

Figure 3

Phase C (BLK)

Ground (GRN)

WYE
3 Hots, 1 Neu, 1 Grnd

Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

Figure 5

Ground (GRN)

HI-LEG DELTA (B High) DELTA & HRG Wye
3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

}

Figure 6

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data:
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240/120V B High Leg Delta
480Y/277V 3Ø Wye
480V 3Ø Delta
600Y/347V 3Ø Wye

L-N

L-G

N-G

L-L

700
700
700/1200
1200
1500

700
700
700/1200
1200
1800
1500

700
700
700/1000
1200
1500

1000
1000
1000/1800
1800
1800
2500

In

20kA
20kA
20kA
20kA
20kA
20kA

SCCR

MCOV

100kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

9.29.15.lh.RevC #8388

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

19

Type 1/Type 2 Surge Protective Device/SPD
Features:

• Directly Connected, Discrete Protection Elements Between
All Possible Modes
• UL 1449 Fourth Edition Listed
• 600 & 900kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Rotary Disconnect Switch included as Standard Equipment
• Dual Redundant Replaceable Module Construction
• All MOV suppression elements monitored
• All Modes of Protection

Performance Specifications

• Directly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode
Protection
Surge Capacities

L-N

600kA Per Phase

200kA

200kA

200kA

200kA

900kA Per Phase

300kA

300kA

300kA

300kA

L-G

N-G

L-L

• UL 1449 Fourth Edition Listed Type 1, CSA 22.2 No. 269.1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed,
CSA 22.2 No. 269.2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 700V
– 480Y/277V: as low as 1200V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits

• AC Sinewave True Tracking Filter with EMI/RFI
Filtering up to -50dB from 10kHz to 100MHz
(Type 2 option only, incl. UL 1283 Listing)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring
Electrically isolated diagnostic circuitry
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 & C-High applications
• For External Mounting next to Switchgear, Motor Controls Centers
or Panelboards
• Individually Fused & Thermally Protected MOVs
• Large-Block, 34mm square, 50kA MOVs
• Dual Redundant Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 52 lbs (23.6 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 20” x 20” x 7.5” (50.8cm x 50.8cm x 19cm)
Lug size: #6 - #1/0 AWG
Typical connection: #6 AWG and 60A breaker

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.2, UL 1283
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

Advanced Protection Technologies
20

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

TEXBL

10-MODE MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XBL

ll

l...

Voltage Code for Electrical System

Surge Current Rating

Options

Common North American Systems:

60 = 600kA/Phase
90 = 900kA/Phase

X

= Surge Counter, six-digit LCD counter
includes maintenance-free Eprom
memory backup

E

= Remote Locatable Display on 4 ft Cable
custom cable lengths available

F

= Noise Filtering - Extended Range &
Attenuation (available on 400kA & 500kA
models)

T

= Thru-Door Rotary Disconnect Switch,
ABB, UL98, E1 enclosure only

K

= Rotary Disconnect Switch, Katko, UL 508

S

= Thru-Door Rotary Disconnect Switch,
Katko, UL 508, E1 enclosure only

2

= Type 2 SPD, incl. UL 1283 EMI/RFI Filters

01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
Other Available Systems - Confirmation encouraged:
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)

Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

Figure 1
}V
}V

Hot (BLK)
Neutral (WHT)
Hot (BLK)
Ground (GRN)

Available Accessory (order separately)
RM = Remote Monitor

Figure 3
Enclosure Rating

Phase A (BLK)
Phase B (ORNG)

SPLIT
2 Hots, 1 Neu, 1 Grnd

}

V

E1 = NEMA 1/12/3R/4 (size: 20” x 20” x 7.5”)
4X = NEMA 4X Non-Metallic (size: 24” x 24”x 8”)

Phase C (BLK)
Neutral (WHT)
Ground (GRN)

Figure 2

(fiberglass, display inside door)

4S = NEMA 4X Stainless Steel (size: 20" x 20"x 7.5")

Phase A (BLK)
B Phase B (BLK)

A
N

C

}

Neutral (WHT)
V

Phase C (BLK)

(display inside door)

HI-LEG DELTA (B High)
P1 = NEMA 1 pullbox ‘indoor’ (size: 20” x 20” x 6”) - includes ‘E’ option
3 Hots, (B HIGH),
FM = NEMA 1 Flush Mount (wall cavity size: 20” x 20”x 6” deep)
1 Neu, 1 Grnd
Figure 3 (Dimensions include
Figure
4 rotary disconnect
Figure
standard
switch.5Optional Thru-DoorFigure 6
handle does not increase enclosure sizes.)

Ground (GRN)

WYE
3 Hots, 1 Neu, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04

=
=
=
=

42
43
44
07

=
=
=
=

240/120V Wye
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye

L-N

L-G

N-G

L-L

In

SCCR

MCOV

700
700
700/1200
1200

700
700
700/1200
1200

700
700
700
1200

1200
1200
1200/1800
1800

20kA
20kA
20kA
20kA

100kA
200kA
200kA
200kA

150
150
150 / 320
320

1200
1200
1200
1200

1200
1200
1200
1200

1200
1200
1200
1200

1800
1800
1800
1800

20kA
20kA
20kA
20kA

200kA
200kA
200kA
200kA

320
320
320
320

Less Common & Specialty
415V/240V 3� Wye
400V/230V 3� Wye
440V/250V 3� Wye
380V/220V 3� Wye

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
9.29.15.lh.RevB #8387

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

21

Features:

• UL 1449 Fourth Edition Listed & CSA 22.2 No. 269.2
• 120kA & 160kA per phase ratings
• Type 2 SPD –
– All UL required OCP & Safety Coordination included inside
– Can be installed load-side of main disconnect
• Replaceable module construction
• 200kA SCCRs
• Voltage Specific Design – Highly configurable
• MOV suppression elements monitored

Performance Specifications

Design Features

Surge Capacities

L-N

N-G

L-L

120kA Per Phase

120kA

120kA

120kA

Standard

160kA Per Phase

160kA

160kA

160kA

Optional

•
•
•
•

UL 1449 4th Edition Listed, UL 1283 Listed & CSA 22.2 No. 269.2
UL 1449-4 Type 2 SPD
UL 1449-4 tested SCCR: 200kA
UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz

Diagnostic Monitoring
•
•
•
•
•
•
•

Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm
Redundant monitoring LEDs on modules
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
• Optional Form C Dry Contacts, 240V, 5A (two sets)
• Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance SuperCap energy storage device

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High
applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused Suppression Modules
• Large-Block 34mm square MOVs
• Replaceable Phase Module Construction
• Thermal Cutout in Each Mode
• Busbar Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•

Advanced Protection Technologies
22

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 25 lbs (11.4 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 12” x 12” x 7.5” (30.5cm x 30.5cm x 19cm)
Lug size: #1/0 - #14 AWG
Typical connection: #6 AWG and 60A breaker

UL 1449 4th Edition, UL 1283 Listed & CSA 22.2 No. 269.2
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested Prior to Shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TE/HP MODEL NUMBER CONFIGURATOR & OPTIONS

ll
TE

ll

/

= Transient Eliminator,
Listed Type 2 SPD
in NEMA 1/3R/04/12
enclosure

HP

/

ll

/

ll

Model Family

kA Rating

HP = HP Family
120kA rating
standard

CL = 160kA Option
(Not Available on
TE/8, 9, 91)

Option Suffixes
(Seperated by slashes -/)
DC = Dry Contacts
Two sets Form C on
terminal strip
FM = Flush Mount enclosure,
NEMA 1 only
(wall cavity size:
12”x12”x6” deep)
SC = Surge Counter

Voltage Code for Electrical System
Common North American Systems:
1 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
2 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
3 = 240/120V High Leg Delta (B High) (Fig 3)
4 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
5 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
8 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

Available Accessory
(order separately):
RM = Remote Monitor

Enclosure Rating
04 = Standard: NEMA 1/3R/04/12

Other Available Systems - Confirmation encouraged:
11
12
51
6
61
7
9
91

=
=
=
=
=
=
=
=

(size: 12” x 12” x 7.5”)

FM = Flush Mount Enclosure, NEMA 1 only

120V Single Phase - 1Ø 2W + Grnd (Fig 5)
240V Single Phase - 1Ø 2W + Grnd (Fig 5)
480V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)
240V Delta - 3Ø 3W+Grnd (Fig 4)
240V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)
380Y/220V Wye - 3Ø 4W+Grnd (Fig 2)
600V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
600V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)

Figure 1
}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)
Ground (GRN)

N

C

}

Neutral (WHT)
V

Phase C (BLK)
Ground (GRN)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

l...

/

(wall cavity size: 12” x 12” x 6”)

4X = NEMA 4X Non-Metallic
(size: 14” x 12”x 6”)
(polycarbonate, display inside clear front door)

4S = NEMA 4X Stainless Steel
(size: 12" x 12"x 6")
(display inside door)

Figure 3

Figure 4

Phase A (BLK)
Phase B (ORNG)

}

}

V

V

Phase C (BLK)

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

}

}V

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

HI-LEG DELTA (B High) DELTA & HRG WYE
3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Figure 6

Hot (BLK)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
1
2
3
4
5
8

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye
480V 3Ø Delta
600Y/347V 3Ø Wye

L-N

N-G

L-L

Type

In

SCCR

MCOV

800
800
800/1200
1200
—
1500

600
600
600
1000
—
1200

1200
1200
1200
1800
1800
2500

Type 2
Type 2
Type 2
Type 2
Type 2
Type 2

5kA
5kA
5kA
5kA
5kA
5kA

200kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

2.1.17.RevE #8397

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

23

Features:
• UL 1449 Fourth Edition Listed & CSA 22.2 No. 269.2
• 80kA, 120kA & 160kA per phase ratings
• Type 2 SPD –
– All UL required OCP & Safety Coordination included inside
– Can be installed load-side of main disconnect

•
•
•
•

Replaceable module construction
200kA SCCRs
Voltage Specific Design – Highly configurable
MOV suppression elements monitored

Performance Specifications

Design Features

Surge Capacities

L-N

N-G

L-L

80kA Per Phase

80kA

80kA

80kA

120kA Per Phase

120kA

120kA

120kA

Optional

160kA Per Phase

160kA

160kA

160kA

Optional

Standard

•
•
•
•

UL 1449 4th Edition Listed, UL 1283 Listed & CSA 22.2 No. 269.2
UL 1449-4 Type 2 SPD
UL 1449-4 tested SCCR: 200kA
UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz

Diagnostic Monitoring
•
•
•
•

Green LED Status indicator per phase
Redundant monitoring LEDs on modules
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
• Optional Form C Dry Contacts, 240V, 5A (two sets)

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High
applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Individually Fused Suppression Modules
• Large-Block 34mm square MOVs
• Replaceable Phase Module Construction
• Thermal Cutout in Each Mode
• Busbar Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•
•

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 25 lbs (11.4 kg)
Standard NEMA 1/12/3R/4 enclosure
Standard size: 12” x 12” x 7.5” (30.5cm x 30.5cm x 19cm)
Lug size: #1/0 - #14 AWG
Typical connection: #6 AWG and 60A breaker

Quality, Standards & Validation
•
•
•
•
•
•
•
•

Advanced Protection Technologies
24

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

UL 1449 4th Edition, UL 1283 Listed & CSA 22.2 No. 269.2
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested Prior to Shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TE/HPS MODEL NUMBER CONFIGURATOR & OPTIONS

ll / ll
TE

= Transient Eliminator,
Listed Type 2 SPD
in NEMA 1/3R/04/12
enclosure

HPS

ll

/

ll

/

Model Family

kA Rating

HPS = HPS Family
80kA rating standard

CX = 120kA Option

Option Suffixes
(Seperated by slashes -/)
DC = Dry Contacts
Two sets Form C on
terminal strip
FM = Flush Mount enclosure,
NEMA 1 only
(wall cavity size:
12”x12”x6” deep)

CL = 160kA Option
(Not Available on
TE/8, 9, 91)

Voltage Code for Electrical System
Common North American Systems:
1 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
2 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
3 = 240/120V High Leg Delta (B High) (Fig 3)
4 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
5 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
8 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

l...

/

Available Accessory
(order separately):
RM = Remote Monitor

Enclosure Rating
04 = Standard: NEMA 1/3R/04/12
(size: 12” x 12” x 7.5”)

Other Available Systems - Confirmation encouraged:

FM = Flush Mount Enclosure, NEMA 1 only

11
12
51
6
61
7
9
91

4X = NEMA 4X Non-Metallic

=
=
=
=
=
=
=
=

(wall cavity size: 12” x 12” x 6”)

120V Single Phase - 1Ø 2W + Grnd (Fig 5)
240V Single Phase - 1Ø 2W + Grnd (Fig 5)
480V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)
240V Delta - 3Ø 3W+Grnd (Fig 4)
240V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)
380Y/220V Wye - 3Ø 4W+Grnd (Fig 2)
600V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
600V B Corner Grnd Delta, 3Ø 3W+Grnd (Fig 6)

Figure 1
}V
}V

Hot (BLK)

Figure 2

Hot (BLK)
Ground (GRN)

N

C

}

}

}

V

Phase C (BLK)

Ground (GRN)

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

Figure 4

V

Neutral (WHT)
V

(size: 12" x 12"x 6")
(display inside door)

Phase A (BLK)
Phase B (ORNG)

B Phase B (BLK)

A

4S = NEMA 4X Stainless Steel

Figure 3

Phase A (BLK)

Neutral (WHT)

(size: 14” x 12”x 6”)
(polycarbonate, display inside clear front door)

}

}V

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

HI-LEG DELTA (B High) DELTA & HRG WYE
3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Figure 6

Hot (BLK)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
1
2
3
4
5
8

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye
480V 3� Delta
600Y/347V 3� Wye

L-N

N-G

L-L

Type

In

SCCR

MCOV

800
800
800/1200
1200
—
1500

600
600
600
1000
—
1200

1200
1200
1200
1800
1800
2500

Type 2
Type 2
Type 2
Type 2
Type 2
Type 2

5kA
5kA
5kA
5kA
5kA
5kA

200kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

2.1.17.RevE #8396

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

25

Features:

• UL 1449 Fourth Edition Listed and CSA 22.2 No. 269.2
• 160kA & 240kA per phase ratings
• Type 2 SPD –
– All UL required OCP & Safety Coordination included inside
– Can be installed load-side of main disconnect
• Replaceable module construction
• 200kA SCCRs
• Voltage Specific – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection
• Optional Silicon Avalanche Diode (SAD) Hybrid System

Performance Specifications
Surge Capacities

L-N

L-G

Design Features
N-G

L-L

160kA Per Phase

80kA

80kA

120kA

160kA

Standard

240kA Per Phase

120kA

120kA

120kA

240kA

Optional

Silicon Avalanche Diode (SAD) Hybrid (120/240 & 208Y/120)
90kA Per Phase

50kA

40kA

120kA

90kA

Optional

130kA Per Phase

50kA

80kA

120kA

130kA

Optional

170kA Per Phase

90kA

80kA

120kA

170kA

Optional

•
•
•
•

•
•
•
•

UL 1449 4th Edition Listed, UL 1283 Listed & CSA 22.2 No. 269.2
UL 1449-4 Type 2 SPD
UL 1449-4 tested SCCR: 200kA
UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 500V
– 480Y/277V: as low as 900V
200kAIR rated fusing
Less than 1 nanosecond response time
Repetitive Impulse: 5,000 hits
AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz

Diagnostic Monitoring
•
•
•
•
•
•
•

Tri-color Green, Amber, Red LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm
Redundant monitoring LEDs on modules
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
• Optional Form C Dry Contacts, 24V, 1A (two sets)
• Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance SuperCap energy storage device

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High applications
• For External Mounting next to Switchgear, Motor Controls Centers
or Panelboards
• Individually Fused Suppression Modes
• Large-Block utility grade 34mm square MOVs
• Replaceable Phase Module Construction
• Thermal Sensitivity in Each Mode
• Busbar Construction
• Solid State Bidirectional Operation
• Busbar connection
• Enclosure-less version for OEM available (XTE Series)

Physical Specifications
•
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•

Advanced Protection Technologies
26

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 25 lbs (11.5 kg)
Standard NEMA 4 (Other Enclosures Optional)
Standard size: 12” x 12” x 7.5” (30.5cm x 30.5cm x 190.5 cm)
Lug size: #2 - #14 AWG
Typical connection: #6 AWG and 60A breaker

UL 1449 4th Edition, UL 1283 Listed & CSA 22.2 No. 269.2
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested Prior to Shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TE/XGA MODEL NUMBER CONFIGURATOR & OPTIONS

ll / ll XGA
TE

= Transient Eliminator, Listed Type 2 SPD
in NEMA 1 enclosure

XTE = Transient Eliminator, Recognized
Type 2 Component Assembly SPD on
backplane for installation within gear
(display on 6’ cable)

Voltage Code for Electrical System

ll

/

ll

/

ll

/

Model Family

Options

XGA = XGA Family
160kA rating standard

/DC = Dry Contacts
Two sets Form C (24V, 1A)
/SC = Surge Counter, six digit LCD

Surge Current Rating

Available Accessory (order separately):
RM = Remote Monitor

/24 = 240kA Option
/09 = 090kA SAD option
(120/240V & 208Y/120)

/13 = 130kA SAD option
Common North American Systems:
(120/240V & 208Y/120)
1 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
/17 = 170kA SAD option
2 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
(120/240V & 208Y/120)
3 = 240/120V High Leg Delta (B High) (Fig 3)
4 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
5 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
Enclosure Rating
8 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)
Other Available Systems - Confirmation encouraged:
11 = 120V Single Phase - 1� 2W + Grnd (Fig 5)
12 = 240V Single Phase - 1� 2W + Grnd (Fig 5)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
6 = 240V Delta - 3� 3W+Grnd (Fig 4)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
7 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
9 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)

Figure 1

}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)
Ground (GRN)

N

C

}

(wall cavity size: 12” x 12” x 6”)

4X = NEMA 4X Non-Metallic (size: 14” x 12”x 6”)
(polycarbonate, display inside clear front door)

4S = NEMA 4X Stainless Steel (size: 12" x 12" x 6")

(display inside door)
(Note: Enclosure-less version for OEM uses XTE prefix)

Figure 4

Phase A (BLK)
Phase B (ORNG)

}

}

V

V

Phase C (BLK)

Ground (GRN)

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

FM = Flush Mount Enclosure, NEMA 1 only

Figure 3

Neutral (WHT)
V

04 = Standard: NEMA 1/3R/04/12 (size: 12” x 12” x 7.5”)

}

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

HI-LEG DELTA (B High) DELTA & HRG WYE
3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Figure 6

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye
480V 3� Delta
600Y/347V 3� Wye

L-N

L-G

N-G

L-L

Type

In

SCCR

MCOV

600
600
600/900
900
—
1200

600
600
600/900
900
1500
1500

600
600
600
800
—
1200

900
900
900/1500
1500
1800
2500

Type 2
Type 2
Type 2
Type 2
Type 2
Type 2

5kA
5kA
5kA
5kA
5kA
5kA

200kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

500
500

600
600

600
600

800
800

Type 2
Type 2

5kA
5kA

200kA
200kA

138
138

SAD Models
01 = 240/120V Split Phase
02 = 208Y/120V 3� Wye

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

10.7.16lh.RevE #8391

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

27

Type 2 Surge Protective Device/SPD/TVSS
Features

• UL 1449 Fourth Edition Listed
• 180kA - 36kA Per Phase ratings (single & split phase)
• 20kA I-nominal (10kA In on 36kA models)
• 100kA SCCRs
• UL 96A Lightning Protection Master Label compliant (@20kA)
• Optional Sinewave Tracking EMI/RFI Noise Filtering
• Pre-attached 10 AWG Leads
• All Modes of Protection
• Data table on back

Performance Specifications

Design Features

Surge Capacities

L-N

L-G

N-G

L-L

180kA Per Phase

90kA

90kA

90kA

180kA

144kA Per Phase

72kA

72kA

72kA

144kA

108kA Per Phase

54kA

54kA

54kA

108kA

72kA Per Phase

36kA

36kA

36kA

72kA

36kA Per Phase*
*10kA In

18kA

18kA

18kA

36kA

•
•
•
•
•
•
•
•

UL 1449 Fourth Edition Listed and CSA 22.2 No. 269.2
UL 1449-4 tested I-nominal: 20kA
UL 1449-4 tested SCCR: 100kA
UL 1449-4 Voltage Protection Ratings (VPRs):
– as low as 700V, including circuit breaker
Less than 1 nanosecond response time
Optional AC Sinewave Tracking Filter with EMI/RFI Filtering
up to -50dB from 10kHz to 100MHz
Repetitive Impulse: 5,000 hits
Data table on back

Physical Specifications
•
•
•
•
•
•
•
•
•

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 40 - 500Hz
Operating Temperature: -40°C (-40°F) to +85°C (185°F)
Weight: 3lbs (1.5kg)
NEMA 4X Polycarbonate enclosure
– UL 746C(f1) & UL 94-5VA
Dimensions: 8.3” x 3.6” x 3.0”
3/4” female threaded hub
Pre-wired with 3’ (1m) of 10 AWG conductor
Typical connection: 10 AWG and 20 - 30A breaker

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643, CE
• High Energy Parallel Design for Category C3 &
C-High applications
• For External Mounting next to Switchgear, Motor Controls
Centers or Panelboards
• Robust 25mm Thermally Protected MOVs
• Solid State Bidirectional Operation

Diagnostic Monitoring
• LED indicator monitoring:
– Separate LEDs for L-N and L-G on each phase
• LEDs extinguish upon Phase Loss
• Optional on Split & Single Phase: Form C Dry Contact,
(Contact rated 240V, 5A; leads are pre-wired through
nipple with 18 AWG )

Quality, Standards & Validation
•
•
•
•
•
•
•
•

UL 1449 Fourth Edition Listed and CSA 22.2 No. 269.2
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

Advanced Protection Technologies
28

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Pending

TEXMS

Model Number Configurator & Options

TE

01

XMS

14

0

C

(Default)

Voltage Code for Electrical System

Build Configuration

Options

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
11 = 120V Single Phase (Fig 2)

XMS = Standard Model

C = Dry Contacts Form C, 240V, 5A (pre-wired)
L = Delete L-N Protection (reduces kA rating)
G = Delete L-G Protection (reduces kA rating)
N = Delete N-G Protection
F = Noise Filtering

Standard Enclosure:
4X = NEMA 4X Non-Metallic (size 8.3” x 3.6” x 3”)

Available Accessory (order separately)
XMFMKIT = Flush Mount Kit

Surge Current Rating
XMS
18
14
10
07
03

=
=
=
=
=

180kA/Phase
144kA/Phase
108kA/Phase
72kA/Phase
36kA/Phase (10kA In)

(Other UL 1449 Listed surge current ratings are available for
OEM or special order. Please contact factory)

Figure 2

Figure 1
}V
}V

}

Hot (BLK)

Hot (BLK)

Neutral (WHT)
Ground (GRN)

Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

Hot (BLK)

V

Neutral (WHT)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

Performance Data TBD
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 6kV, 3kA)

Common North American Systems
L-N

L-G

N-G

L-L

Type

In

SCCR

MCOV

01 =

240/120V Split Phase

700

700

700

1000

Type 2

20kA

100kA

150

11 =

120 Single Phase

700

700

700

–

Type 2

20kA

100kA

150

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.

9.29.15.lh.RevD #8814

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

29

Component Assembly SPDs
Type 1 and Type 2
Features:

• UL 1449 Fourth Edition Recognized
• 100kA – 300kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection
• Display on 28” cable

Performance Specifications
Surge Capacities

Design Features

L-N

L-G

N-G

L-L

100kA Per Phase

50kA

50kA

50kA

100kA

150kA Per Phase

100kA

50kA

50kA

150kA

200kA Per Phase

100kA

100kA

100kA

200kA

250kA Per Phase

150kA

100kA

100kA

250kA

300kA Per Phase

150kA

150kA

150kA

300kA

• UL 1449 4 Edition Recognized Type 1 CA, CSA 22.2 No. 269.4-1
• Optional UL 1449-4 Type 2 CA, UL 1283 Rec.,
CSA 22.2 No. 269.4-2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz (Type 2 option only, incl. UL 1283 Rec.)
th

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & Dry Contacts)
Electrically isolated circuitry ensures surges do not damage diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory
Installer-locatable display on 28” cable

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High applications
• For Mounting Internal to Switchgear, Motor Controls Centers,
Panelboards or Control Panels
• Individually Fused & Thermally Protected MOVs
• Large-Block 34mm square MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
30

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
wwwaptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 5 lbs (2.3 kg)
Standard size: 6.5” x 11” x 4.5” (16.5cm x 29.9cm x 11.4cm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.4-1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.4-2, UL 1283 Rec.
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643,
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXRS

MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XRS

Voltage Code for Electrical System

l...

Surge Current Rating

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
08 = 600Y/347V Wye - 3Ø 4W+Grnd (Fig 2)

10
15
20
25
30

=
=
=
=
=

Options
X = Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup

100kA/Phase
150kA/Phase
200kA/Phase
250kA/Phase
300kA/Phase

M = Mount Display on SPD instead of Cable
D = Rotary Disconnect Switch, ABB, UL98,
SPD & Disconnect mounted on alum.
backplane (10.75” x 10.88” x 4.5”)

Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd, (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
(Available: 100kA, 150kA)
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(Available: 100kA, 150kA)
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)

Figure 1

}V
}V

Hot (BLK)

Figure 2

Hot (BLK)
Ground (GRN)

C

}

}

Display on 28” Cable - other lengths available—
consult factory
Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering
Available Accessory (order separately)
RM = Remote Monitor

Figure 4

}

V

V

Neutral (WHT)
V

Extended Disc. Sw. handle hardware available—
consult factory

Phase A (BLK)
Phase B (ORNG)

B Phase B (BLK)
N

2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters

Figure 3

Phase A (BLK)
A

Neutral (WHT)

K = Rotary Disconnect Switch, Katko UL 508,
SPD & Disconnect mounted on alum
backplane (10.75” x 10.88” x 4.5”)

Phase C (BLK)

Ground (GRN)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

Figure 5

Ground (GRN)

}

Figure 6

Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

HI-LEG DELTA (B High) DELTA & HRG Wye
3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

}V

Hot (BLK)

V

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye
480V 3� Delta
600Y/347V 3� Wye

L-N

L-G

N-G

L-L

700
700
700/1200
1200
1500

700
700
700/1200
1200
1800
1500

700
700
700
1200
1500

1200
1200
1800
2000
1800
2500

In

20kA
20kA
20kA
20kA
20kA
20kA

SCCR

MCOV

100kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at CustomerCare@ASCO.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect switch may increase VPRs.
10.16.17.RevD

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

31

Component Assembly SPDs
Type 1 and Type 2
Features:

Performance Specifications

• Directly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode
Protection
Surge Capacities

L-N

L-G

N-G

L-L

150kA Per Phase

50kA

50kA

50kA

50kA

• Directly Connected, Discrete Protection Elements Between
All Possible Modes
• UL 1449 Fourth Edition Recognized
• 150kA - 300kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection
• Display on 28” cable

100kA 100kA 100kA 100kA
300kA Per Phase
• UL 1449 4th Edition Recognized. Type 1 CA, CSA 22.2 No. 269.4-1
• Optional UL 1449-4 Type 2 SPD, UL 1283 Listed, CSA 22.2
No. 269.4-2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits

• AC Sinewave Tracking Filter with EMI/RFI Filtering up
to -50dB from 10kHz to 100MHz (Type 2 option only,
incl. UL 1283 Listing)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & Dry Contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function,
reset & no-maintenance Eprom memory
Installer-locatable display on 28” cable

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002, C62.622010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High applications
• For Mounting Internal to Switchgear, Motor Controls Centers,
Panelboards or Control Panels
• Individually Fused & Thermally Protected MOVs
• Large-Block 34mm square MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
32

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 5 lbs (2.3 kg)
Standard size: 6.5” x 11” x 4.5” (16.5cm x 29.9cm x 11.4cm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker
Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.4-1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.4-2, UL 1283 Rec.
UL file: VZCA.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested prior to shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXRL

10-MODE MODEL NUMBER CONFIGURATOR & OPTIONS

ll

TE

ll

XRL

l...

Voltage Code for Electrical System

Surge Current Rating

Options

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd, (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd, (Fig 2)
03 = 240/120V High Leg Delta (B High), (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd, (Fig 2)

15 = 150kA/Phase
30 = 300kA/Phase

X = Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup
M = Mount Display on SPD instead of cable
D = Rotary Disconnect Switch, ABB, UL98, SPD
& Disconnect mounted on alum. backplane
(10.75” x 10.88” x 4.5”)
K = Rotary Disconnect Switch, Katko UL 508,
SPD & Disconnect mounted on alum.
backplane (10.75” x 10.88” x 4.5”)

Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd, (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)

2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters
Extended Disc. Sw. handle hardware available—
consult factory
Display on 28” Cable - other lengths available—
consult factory
Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

Figure 1
}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)

N

Hot (BLK)
Ground (GRN)

C

}

Phase A (BLK)
Phase B (ORNG)

}

V

Neutral (WHT)
V

Phase C (BLK)
Neutral (WHT)
Ground (GRN)

Phase C (BLK)
Ground (GRN)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

Available Accessory (order separately)
RM = Remote Monitor

Figure 3

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04

=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye

L-N

L-G

N-G

L-L

In

SCCR

MCOV

700
700
800/1500
1200

700
700
700/1200
1200

700
700
700
1200

1000
1000
1800
1800

20kA
20kA
20kA
20kA

100kA
200kA
200kA
200kA

150
150
150 / 320
320

700
700
1200
1200
1200
1200

1000
1000
1800
1800
1800
1800

20kA
20kA
20kA
20kA
20kA
20kA

100kA
100kA
200kA
200kA
200kA
200kA

180
180
320
320
320
320

Other Available Systems - Confirmation Encouraged:
15
21
42
43
44
07

=
=
=
=
=
=

254/127V Split
220Y/127V 3Ø
415Y/240V 3Ø
400Y/230V 3Ø
440Y/250V 3Ø
380Y/220V 3Ø

Phase
Wye
Wye
Wye
Wye
Wye

700
700
1200
1200
1200
1200

700
700
1200
1200
1200
1200

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect may increase VPRs.
10.16.17.lh.RevD #8392

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

33

Component Assembly SPDs
Type 1 and Type 2
Features:
• UL 1449 Fourth Edition Recognized
• 300kA – 500kA per phase ratings

• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
•
•
•
•
•
•
•

Performance Specifications

Design Features

Surge Capacities

L-N

L-G

N-G

L-L

300kA Per Phase

150kA

150kA

150kA

300kA

400kA Per Phase

200kA

200kA

200kA

400kA

500kA Per Phase

250kA

250kA

250kA

500kA

• UL 1449 4 Edition Recognized Type 1 CA, CSA 22.2 No. 269.4-1
• Optional UL 1449-4 Type 2 CA, UL 1283 Rec., CSA 22.2
No. 269.4-2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• AC Sinewave Tracking Filter with EMI/RFI Filtering up to -50dB
from 10kHz to 100MHz (Type 2 option only, incl. UL 1283 Rec.)
th

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•
•

20kA Inominal (In)
200kA SCCRs (most models)
UL 96A Lightning Protection Master Label compliant
Voltage Specific Design – Highly configurable
All MOV suppression elements monitored
All Modes of Protection
Display on 28” cable

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED Service indicator
Audible Alarm with Silence Switch
Test Function: toggles Red Service LED, Audible Alarm &
Dry Contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage
diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance Eprom memory
Installer-locatable display on 28” cable

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 &
• C-High applications
• For Mounting Internal to Switchgear, Motor Control Centers,
Panelboards or Control Panels
• Individually Fused & Thermally Protected MOVs
• Large-Block 34mm square MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Advanced Protection Technologies
34

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 7 lbs (3.2 kg)
Standard size: 9” x 11” x 5.3” (22.9cm x 28.0cm x 13.5cm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.4-1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.4-2, UL 1283 Rec.
UL file: VZCA2.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested Prior to Shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

TEXWS

MODEL NUMBER CONFIGURATOR & OPTIONS

TE

ll

XWS

Voltage Code for Electrical System

Other Available Systems - Confirmation encouraged:
15 = 254/127V Split Phase - 1� 3W+Grnd, (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
41 = 520Y/300V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(Available: 300kA, 450kA)
06 = 240V Delta - 3� 3W+Grnd (Fig 4)
(Available: 300kA, 450kA)
61 = 240V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(Available: 300kA, 450kA)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)
09 = 600V Delta - 3� 3W+Grnd (Fig 4) & HRG Wye
(Available: 200kA, 250kA)
91 = 600V B Corner Grnd Delta, 3� 3W+Grnd (Fig 6)
(Available: 200kA, 250kA)
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)

}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)

N

Ground (GRN)

C

}

25 = 250kA/Phase
(Voltage Codes 09 & 91 only)

M = Mount Display on SPD instead of Cable

(Voltage Codes 05, 51, 06, 61 only)

D = Rotary Disconnect Switch, ABB, UL98,
SPD & Disconnect mounted on alum.
backplane (14.75” x 12.88” x 5.25”)

50 = 500kA/Phase

K = Rotary Disconnect Switch, Katko UL 508, SPD
& Disconnect mounted on alum backplane
(14.75” x 12.88” x 5.25”)
2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters
Extended Disc. Sw. handle hardware available—
consult factory
Display on 28” Cable - other lengths available—
consult factory
Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

Available Accessory (order separately)
RM = Remote Monitor

Figure 4

}

V

Phase C (BLK)

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Ground (GRN)

F = Noise Filtering - Extended Range &
Attenuation

31 = 300kA/Phase
40 = 400kA/Phase
45 = 450kA/Phase

V

Phase C (BLK)

X = Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup

20 = 200kA/Phase

Phase A (BLK)
Phase B (ORNG)

}

Options

(Voltage Codes 09 & 91 only)

Figure 3

Neutral (WHT)
V

l...

Surge Current Rating

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)
05 = 480V Delta - 3Ø 3W+Grnd (Fig 4) & HRG Wye
(Available: 300kA, 450kA)
08 = 600Y/347 Wye - 3Ø 4W+Grnd (Fig 2)

Figure 1

ll

Ground (GRN)

}

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

SPLIT
WYE
HI-LEG DELTA (B High) DELTA & HRG Wye
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd 3 Hots, (B HIGH),
3 Hots, 1 Grnd
1 Neu, 1 Grnd

Figure 6

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3� Wye
240Y/120V B High Leg Delta
480Y/277V 3� Wye
480V 3� Delta
600Y/347V 3� Wye

L-N
700
700
700/1200
1200
1500

L-G
600
600
600/1000
1000
1800
1500

N-G
600
600
600
1200
1500

L-L
1000
1000
1500
1800
1800
2500

In
20kA
20kA
20kA
20kA
20kA
20kA

SCCR
100kA
200kA
200kA
200kA
200kA
200kA

MCOV
150
150
150 / 320
320
550
420

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect may increase VPRs.
9.29.15.lh.RevC #8395

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

35

Features:

• Directly Connected, Discrete Protection Elements Between All
Possible Modes
• UL 1449 Fourth Edition Recognized
• 300kA - 450kA per phase ratings
• All UL required OCP & Safety Coordination included inside
– Type 1 SPDs intended for Line or Load Side of Main Disconnect
– Type 2 SPDs intended for Load Side of Main Disconnect
• 20kA Inominal (In)
• 200kA SCCRs (most models)
• UL 96A Lightning Protection Master Label compliant
• Voltage Specific Design – Highly configurable
• All MOV suppression elements monitored
• All Modes of Protection
• Display on 28” cable

Performance Specifications

• Directly Connected, Discrete Protection Elements
Between All Possible Modes with True 10-Mode
Protection
Surge Capacities

L-N

L-G

300kA Per Phase

100kA

100kA

100kA

100kA

450kA Per Phase

150kA

150kA

150kA

150kA

N-G

L-L

• UL 1449 4th Edition Recognized Type 1 CA, CSA 22.2 No. 269.4-1
• Optional UL 1449-4 Type 2 CA, UL 1283 Rec., CSA 22.2
No. 269.4-2
• UL 1449-4 tested Inominal (In): 20kA
• UL 1449-4 tested SCCR: 200kA & 100kA
• UL 1449-4 Voltage Protection Ratings (VPRs):
– 208Y/120V: as low as 600V
– 480Y/277V: as low as 1000V
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits

• AC Sinewave Tracking Filter with EMI/RFI Filtering up
to -50dB from 10kHz to 100MHz (Type 2 option only,
incl. UL 1283 Rec.)

Diagnostic Monitoring
•
•
•
•
•
•
•
•
•
•
•

100% monitoring – Every MOV is monitored, incl. N-G
Green LED Status indicator per phase
Red LED service indicator
Audible Alarm with Silence Switch
Test Function: toggles red service LED, audible alarm & dry
contact (if equipped)
N-G overvoltage detection
Phase Loss monitoring (toggles LED & dry contacts)
Electrically isolated circuitry ensures surges do not damage diagnostics
Form C Dry Contacts, 240V, 5A (two sets)
Optional Surge Counter, six-digit LCD, with test function, reset &
no-maintenance Eprom memory
Installer-locatable display on 28” cable

Design Features
• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, C62.45-2002,
C62.62-2010 and C62.72-2007
– NEMA LS-1
– NEC® Article 285
– IEC 61643
• High Energy Parallel Design for Category C3 & C-High applications
• For Mounting Internal to Switchgear, Motor Controls Centers,
Panelboards and Control Panels
• Individually Fused & Thermally Protected MOVs
• Large-Block 34mm square MOVs
• Replaceable Module Construction
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•
•

Relative Humidity Range: 0 -95% non-condensing
Operating Frequency: 47-63Hz
Operating Temperature: -25°C (-15°F) to +60°C (140°F)
Weight: 7 lbs (3.2 kg)
Standard size: 9” x 11” x 5.3” (22.9cm x 28.0cm x 13.5cm)
Lug size: #2 - #14 AWG (w/opt. disconnect: #6 - #1/0)
Typical connection: #6 AWG and 60A breaker

Quality, Standards & Validation
•
•
•
•
•
•
•
•
•

Type 1: UL 1449 Fourth Edition, CSA 22.2 No. 269.4-1
Type 2 (Opt.): UL 1449 Fourth Ed., CSA No. 269.4-2, UL 1283 Rec.
UL file: VZCA2.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
10 year warranty (longer optional)
Burn-In tested Prior to Shipment
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification

Advanced Protection Technologies
36

Component Assembly SPDs
Type 1 and Type 2

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

TEXWL

10-MODE MODEL NUMBER CONFIGURATOR & OPTIONS

TE

ll

XWL

Voltage Code for Electrical System

ll

Surge Current Rating
31 = 300kA/Phase
45 = 450kA/Phase

Common North American Systems:
01 = 240/120V Split Phase - 1Ø 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Ø 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Ø 4W+Grnd (Fig 2)

l...
Options
X = Surge Counter, six-digit LCD counter
includes maintenance-free Eprom memory
backup
F = Noise Filtering - Extended Range &
Attenuation
M = Mount Display on SPD instead of cable
D = Rotary Disconnect Switch, ABB, UL98, SPD
& Disconnect mounted on alum. backplane
(14.75” x 12.88” x 5.25”)

Other Available Systems - Confirmation encouraged:
15 = 254Y/127V Split Phase - 1� 3W+Grnd, (Fig 1)
18 = 480/277V 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3� 4W+Grnd (Fig 2)
42 = 415Y/240V Wye - 3� 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3� 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3� 4W+Grnd (Fig 2)
07 = 380Y/220V Wye - 3� 4W+Grnd (Fig 2)

K = Rotary Disconnect Switch, Katko UL 508,
SPD & Disconnect mounted on alum.
backplane (14.75” x 12.88” x 5.25”)
2 = Type 2 SPD, incl. UL 1283 EMI/RFI Filters
Extended Disc. Sw. handle hardware available—
consult factory
Display on 28” Cable - other lengths available—
consult factory

Figure 1
}V
}V

Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)

N

Ground (GRN)

C

}

Figure 3
Phase A (BLK)
Phase B (ORNG)

}

Phase C (BLK)
Neutral (WHT)
Ground (GRN)

Phase C (BLK)
Ground (GRN)

SPLIT
WYE
2 Hots, 1 Neu, 1 Grnd 3 Hots, 1 Neu, 1 Grnd

Available Accessory (order separately)
RM = Remote Monitor

V

Neutral (WHT)
V

Delete Options - Consult Factory for Order Code
Delete L-N Protection (reduces kA rating)
Delete L-G Protection (reduces kA rating)
Delete N-G Protection (reduces kA rating)
Delete Noise Filtering

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

Performance Data
UL 1449 Fourth Edition Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04

=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye

L-N

L-G

N-G

L-L

In

SCCR

MCOV

700
700
700/1200
1200

700
700
700/1000
1000

600
600
600
1000

1000
1000
1500
1800

20kA
20kA
20kA
20kA

100kA
200kA
200kA
200kA

150
150
150 / 320
320

700
700
1000
1000
1000
1000

1000
1000
1800
1800
1800
1800

20kA
20kA
20kA
20kA
20kA
20kA

100kA
100kA
200kA
200kA
200kA
200kA

180
180
320
320
320
320

Other Available Systems - Confirmation Encouraged:
15
21
42
43
44
07

=
=
=
=
=
=

254/127V Split Phase
220Y/127V 3Ø Wye
415Y/240V 3Ø Wye
400Y/230V 3Ø Wye
440Y/250V 3Ø Wye
380Y/220V 3Ø Wye

700
700
1200
1200
1200
1200

700
700
1000
1000
1000
1000

Other Available Systems:

Please see supplementary data sheet, contact us at info@aptsurge.com
or confirm at www.UL.com using CCN of VZCA.
Optional disconnect may increase VPRs.
9.29.15.lh.RevC #8394

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

37

DIN-Rail SPDs
AC Power & DC PV

Type 1 Component Assembly

Intended for use in Type 1 or Type 2 Applications
Features
•
•
•
•
•
•
•
•
•

UL 1449 Fourth Edition Recognized
Parallel Electrical Connection – Easy to install
50kA per mode
All UL required OCP & Safety Coordination included inside
– Supplemental Fusing/OCP Not Required
UL 1449-4: 20kA Inominal
UL 1449-4: 200kA SCCRs
Large-Block 34mm sq. MOVs
– Individually Fused & Thermally Protected
Diagnostic Monitoring - Visual Indicator Tabs
Optional Form C Normally Open/Closed Dry Contact

Performance Specifications

Design Features

• Data Table on Back

• Designed, Manufactured & Tested consistent with:
– ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
– NEC® Article 285
– IEC 61643-11, CE
• High Energy Parallel Design for Category C3 &
C-High Applications
• For Internal mounting within control panels, medical,
telecom, drives, security systems, robotics, etc.
• Less than 1 nanosecond response time
• Repetitive Impulse: 5,000 hits
• Solid State Bidirectional Operation

Physical Specifications
•
•
•
•
•
•

Relative Humidity Range: 0 - 95% non-condensing
Operating Frequency: 47 - 63Hz
Operating Temperature: -40°C (-40°F) to +85°C (185°F)
Polymeric Enclosure: Flame rated UL94 V-0
Weight: 0.25 lbs (114 kg) per pole
Wire Lug Size: #6 - #14 AWG

Dimensions
• Uses standard 35mm DIN-Rail (4-pole shown)
Width

Optional Dry Contact

Length

Height

1-Pole: 0.70” (17.8mm)

4.09” (103.9mm)

2.70” (68.5mm)

2-Pole: 1.39” (35.5mm)

4.09” (103.9mm)

2.70” (68.5mm)

3-Pole: 2.10” (53.3mm)

4.09” (103.9mm)

2.70” (68.5mm)

4-Pole: 2.80” (71.0mm)

4.09” (103.9mm)

2.70” (68.5mm)

0.41”
10.5mm
TYP.

2.80”
71.0mm

•
•
•
•

‘M’ Suffix Option
Form C: Normally Open or Normally Closed
Contact Wire Size: #16 - #30 AWG
Torque: 2.0 lb-in
Contact Rating: 125Vac, 3A maximum
NO

0.70”
17.8mm
TYP.

COMMON

0.43”
11.0mm

NC

1
2
3

125Vac
3A max

Quality, Standards & Validation
4.09”
103.9mm

3.58”
1.77”
91.0mm 45.0mm

1.09”
27.7mm

WIRE MARKER
LOCATION

0.27”
6.9mm

0.20”
5.1mm
INDICATOR
IN TRIPPED
POSITION

2.70”
68.5mm

1.93”
49.0mm

•
•
•
•
•
•
•

Advanced Protection Technologies
38

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

UL 1449 Fourth Edition Recognized, cUL
UL file: VZCA2.E321351 at www.UL.com
RoHS-compliant
IEC 61643, CE
5 year warranty (longer optional)
ISO 9001:2008 Quality Management System
ISO 17025:2005 Laboratory Qualification
European Authorized Representative
Obelis s.a.
Boulevard Général Wahis 53
1030 Brussels, BELGIUM
Tel: +(32) 2. 732.59.54
Fax: +(32) 2. 732.60.03
E-Mail: mail@obelis.net

Application & Installation Guide

DIN Model Configurator & Option:

Parallel Electrical Connections for Easy Installation

D
DIN

(Default)

System

240V

M = Monitoring
Dry Contact

2P = Two Pole,
Split Phase

EXAMPLES:
D120V3P
120V, 3 pole
(208Y/120V)

3P = Three Pole
Wye

277V
347V

D277V3PNGM
50kA, 277V, 3 pole
(480Y/277V) with
PV = Photovoltaic DC
N-G with Monitoring
(DC+, DC-, Ground) (Dry Contact)

480V

3PD = Three Pole
Delta

Photovoltaic
DC Voltages

D1000VPV
1000V DC
(DC+, DC-, Ground)

600V (DC)
1000V (DC)

Performance Data
Model

System
Voltage &
Config

# of
Poles

UL 1449
VPR
(6kV - 3kA)

In

SCCR

MCOV

D120V1P

120V

1

600

20kA

200kA

150

D120V2P

120/240V

2

600

20kA

200kA

150

D120V3P

208Y/120V

3

600

20kA

200kA

150

D120V3PNG 208Y/120V w/N-G

4

600

20kA

200kA

150

D127V1P

1

600

20kA

200kA

180

127V

D127V2P

127/254V

2

600

20kA

200kA

180

D127V3P

220Y/127V

3

600

20kA

200kA

180

D127V3PNG 220Y/127V w/N-G

4

600

20kA

200kA

180

D230V1P

230V

1

800

20kA

200kA

270

D230V2P

230/460V

2

800

20kA

200kA

270

D240V3PD

240V Delta

3

800

20kA

200kA

270

D240V3PDG

240V Delta

3

800

20kA

200kA

270

D277V1P

277V

1

1200

20kA

200kA

320

D277V3P

480Y/277V

3

900

20kA

200kA

320

D277V3PNG 480Y/277V w/N-G

4

1200

20kA

200kA

320

D347V3P

3

1200

20kA

200kA

420

D347V3PNG 600Y/347V w/N-G

4

1500

20kA

200kA

420

D480V3PD

480V Delta

3

1500

20kA

200kA

550

D480V3PDG

480V Delta

3

1500

20kA

200kA

550

600Y/347V

1 Pole / Single Phase

230V

1P = One Pole,
Single Phase

# of
Poles

UL 1449
VPR
(6kV - 3kA)

In

SCCR

MCOV

750VDC

D600VPV

600VDC

2

2000

20kA

10kADC

D600VYPV

600VDC

3

2000

20kA

10kADC

720VDC

D1000VPV

1000VDC

3

3000

20kA

10kADC

1250VDC

D1000VYPV

1000VDC

3

3000

20kA

10kADC

1250VDC

(PV DC models are URus. Canadian PV SPD standards not yet established.)
10.19.15.lh.RevC #8776

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

N-G BONDED:
Does NOT require N-G protection

DOWNSTREAM OF N-G BOND:
N-G protection suggested

BLK

BLK

WHT

WHT

GRN

Neutral (WHT)
Ground (GRN)

VOLTAGE

MODEL #

MODEL #

120V
127V
230V
277V

D120V1P
D127V1P
D230V1P
D277V1P

D120V2P
D127V2P
2-D230V1P
2-D277V1P

BLK

BLK

BLK

WHT

BLK

Hot (BLK)
Neutral (WHT)
Hot (BLK)
Ground (GRN)

WHT

GRN

WHT

VOLTAGE

MODEL #

MODEL #

120V (120 / 240V)
127V (127 / 254V)
230V (230 / 460V)

D120V2P
D127V2P
D230V2P

D120V2P + D120V1P
D127V2P + D127V1P
D230V2P + D230V1P
BLK

BLK

BLK
BLK

BLK

GRN

Phase A (BLK)
A

B

Phase B (BLK)
Neutral (WHT)

N
Phase C (BLK)
C

Ground (GRN)
WHT

WHT

VOLTAGE
120V (208Y / 120V)
127V (200Y / 127V)
277V (480Y / 277V)
347V (600Y / 347V)

MODEL #
D120V3P
D127V3P
D277V3P
D347V3P

BLK

BLK

BLK

BLK

MODEL #
D120V3PNG
D127V3PNG
D277V3PNG
D347V3PNG

BLK

BLK

BLK

BLK

Phase A (BLK)
A
C

B

Phase B (BLK)
Phase C (BLK)
Ground (GRN)

VOLTAGE
240V
480V
600V

BLK

MODEL #
D240V3PD
D480V3PD
N/A

(*Do not connect anything to SPD Neutral
connection. Leave SPD’s Neutral floating)

BLK

RED

GRN

MODEL #
D240V3PDG
D480V3PDG
D347V3PNG*

Corner Grounded Delta?
Use same models and connect one SPD Black & Green to Ground.

DC Photovoltaic

System
Voltage &
Config

Installed > 10’ (3m)
From Service Entrance
or Transformer

BLK

Photovoltaic DC
Model

Installed at
Service Entrance
or Transformer

Hot (BLK)

2 Pole / Split Phase

127V

Wye

120V

Option

Delta

AC Voltage

System
Configuration

RED

GRN

BLK

DC+ (RED)

DC- (BLK)
Ground (GRN)

2 Pole
PV SPD

3 Pole
PV SPD

GRN

VOLTAGE
600VDC
1000VDC

MODEL #
D600VPV
N/A

MODEL #
D600VYPV
D1000VPV
D1000VYPV

Modularity allows for many additional configurations.
Call factory for assistance.

39

Arrestor SPD Robustness for In-Line, Series-Connected
DIN-Rail Applications
Features & Where This Makes Sense:

SPD connects via
feed-thru connection
on Std 35mm DIN Rail

Load
conductors

• 50kA Service Entrance rated SPD
– Suitable for UL 96A Lightning Protection System
• High Surge Environments: Outdoor, Pole-Mount, Traffic, ITS
• Robust Arrestor Grade Components
– No ‘dwarf’ suppression elements
• UL 1449 4th Edition Listed SPD – UL Mark
– Avoids regulatory or compliance issues
• Type 1 SPD - does not require separate overcurrent protection at
additional cost & space
• Includes On-Board LED diagnostics
• No More Costly Than Traditional In-Line SPD (Maybe Less When Extra
Fusing is Required)

Disadvantages of Traditional Series-Connected SPDs:
•
•
•
•

Power feeds through

Not robust (take one apart: small dwarf/electronic grade MOVs)
Usually need extra cost & extra space for overcurrent protection
Not UL Listed (Series SPDs are historically Recognized, not Listed)
Not UL Recognized (dangerous? - mfg knew it would not pass recent
UL 1449 changes?)
• UL Recognized with substantial shortcomings?(‘Surprises’ buried in File’s
Conditions of Acceptability?)
• Series SPDs can completely deenergize their loads if their fuse/breaker clears.
Unacceptable to critical loads such as traffic control cabinets, fire alarm panels, etc.

Installation Instructions & Photos on Back
• For Indoor Use Only - Up to 600V, 35A, UL Recognized Connectors
• APT Technical Support at (800) 237-4567

Ordering Information (SPDee is Ordered Separately):
• SKIT 1 – for 120V (true single phase): 1 Hot, 1 Neutral, 1 Ground Includes two Altech CMC1-2 term blocks, two Altech CGT6N term
blocks, one EPCMC-1-2 end plate, label
• SKIT 2 – for 120/240V (split phase): 2 Hots, 1 Neutral, 1 Ground Includes three Altech CMC1-2 term blocks, two Altech CGT6N term
blocks, one EPCMC-1-2 end plate, label
• SKIT 3 – for 208Y/120V (three phase, rare for series application): 3 Hots, 1 Neutral, 1 Ground
• ‘D’ suffix option – Adds 6” 35mm DIN-Rail and two mounting screws (example: SKIT1D)

Component Specifics (Or To Build Your Own):
• Energized and Neutral Feed-Through Terminal Blocks: Altech CMC1-2, Gray, tri-connect, 600V, 35A, 22-10 AWG,
Altech EPCMC1-2 end plate, cЯUus, file E220514
• Ground Feed-Through Terminal Blocks: Altech CGT6N, Green/Yellow, 600V, 35A, 22-10 AWG, cЯUus, file E220514
(two required – one connects feed-through ground leads to DIN rail ground, other connects SPD to DIN-Rail ground)
• Identification Label for affixing to SPDEE SPD.

Advanced Protection Technologies
40

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Installation:
• Qualified Personnel Only - Follow all applicable codes - Ensure all loads are de-energized - Do not install during lightning storm.
• Select appropriate SPDEE from SPDEE datasheet. SPDEE mounts to DIN-Rail as standard feature.
(Alternate mounting possible - SPD does not have to be mounted on DIN-Rail)
• Select appropriate S-KIT, or build your own from Feed-Through Terminal Blocks (Altech, Wago, etc.).
• Ensure DIN-Rail is solidly electrically grounded.
• Connect SPDEE and Feed-Through Terminal Blocks to DIN-Rail, covering exposed side(s) with end plate.
• Wire SPD hot and neutral leads to terminal blocks. Cut leads as short as possible. (May fit better in top terminals) Torque: 7 lb-in
• Wire load connections into and out-of terminal blocks. Torque: 7 lb-in
• Wire SPD ground to one of two grounding blocks. (One grounds SPD to DIN-Rail, other grounds feed-through ground leads).
• Ensure leads are tight. Energize. Ensure LED illuminates.

Load – Out (or In,
can go either way)

Standard SPDee
LED visible here
Supplemental label
affixes to SPDEE

Mounts and
Grounds thru std
35mm DIN-Rail
Make sure rail
is electrically
grounded

Two ground terminals:
• One provides
feed-thru connection
to existing ground
conductor and
simultaneously
grounds to DIN-Rail
• One connects SPD
ground to DIN-Rail
ground, bonding
grounds together

Three Position Feed-Thru
Terminal Blocks:
One for each Energized
Black conductor

Nut tightens
aluminum
L-bracket to
DIN-Rail

One for Neutral
• Strip & Install SPD lead to
upper lug (all three terminals
are connected together)
• Strip & Install feed-through
load conductors on bottom

Leads
from
Load

• Make leads short as possible – inches matter!
• Gentle radius – no sharp bends

Load – Out (or In,
can go either way)

KEY
SPD Hot
SPD Ground
SPD Connection to Terminal Block –
Upper & Lower Terminals inside Terminal
Block are connected to each other

3.10.15.lh # 8678

= Power
= Neutral (white)
= Ground

SPD Netural

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

41

Features:
•
•
•
•
•
•
•
•
•
•
•
•

Budget Surge Protection
Intended for outdoor loads, light poles, DOT, etc.
20kA and 40kA Per Mode Surge Current Ratings
Hi-Energy MOV based design
Low Clamping Voltages – better protection than air-gap,
spark-gap, GDT or silica oxide varistor technologies
Encapsulated in Ceramgard® elastomeric potting
compound for below grade application
Voltage Specific Design – Highly configurable
Pre-attached 12 AWG 24” Leads
Parallel Connection - Solid State Bidirectional Operation
Optional EMI/RFI Noise Filter (1 & 2 pole models)
Optional series type connection (aka two-port,
Kelvin-connected or feed-thru connection)
All Modes of Protection

Model Number Configurator on Back
Performance Specifications:

Mounting Configurations: (graphic on back)

• Available Surge Current Capacities:
20kA in each of all specified modes
40kA in each of all specified modes
• Nominal DIscharge Current Rating (In): 20kA
• Operating Frequency: DC-500Hz
• Operating Temperature: -40°C (-40°F) to +85°C (185°F)
• Weight: 1.65 lbs (0.75 kg)
• Polycarbonate enclosure – UL 746C(f1) & UL 94-5VA
• 3/4” male threaded hub
• 10A upstream overcurrent protection recommended
• Maximum Continuous Operating Voltage (MCOV):

• Intended for mounting via nipple hub (1.05” OD)
• B suffix option mounting bracket permits mounting on flat
surface or standard 35mm DIN-Rail

Nominal System Voltage:
120-127V
220-240V
277V
347V
480V
600V

SPD MCOV:
175V
320V
420V
550V
625V
1000V

Lead Configurations: (graphic on back)
• Standard configuration: 12 AWG leads exit the mouth of
the SPD enclosure, not the nipple. This ensures maximum
potting coverage around the leads for environmental &
moisture protection.
• N suffix option: Moves 12 AWG leads to exit thru the nipple
area (unit is still potted).
• S suffix option: Provides Series connection leads thru the
mouth (not available with N option). This is also known as
two-port, Kelvin or feed-thru connection. Some DOT light pole
configurations require this. Steady state current rating for S
option is 12A. Not intended for continuous loads above 12A.

Advanced Protection Technologies
42

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

3.75”
Weight: 1.65 lbs
(0.75 kg)

3.26”

3.31”

2.9”

3.57”

3/4”-14

1.15”

Sized for std 35mm DIN-rail

Quality, Standards & Validation:
• Designed, Manufactured & Tested consistent with:
ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002
• High Energy Parallel Design for Category C3 &
C-High applications
• UL Recognized MOVs & EMI/RFI Filter
• RoHS-compliant
• 2 year warranty (longer optional)
• Burn-In tested Prior to Shipment
• ISO 9001:2008 Quality Management System
• ISO 17025:2005 Laboratory Qualification

LA MODEL NUMBER CONFIGURATOR & OPTIONS

llll

LA
Voltage
(see Figures)

ll

l...

kA Rating Per Mode

Options

20 = 20kA
40 = 40kA

B

= Aluminum Mounting Bracket

F

= EMI/RFI Noise Filter

(B or C suggested when at
service entrance)

N

= Thru-nipple conductors

(suggested when close to
service entrance)

S

= Series connected, aka
Kelvin connection
An energized lead into the
SPD and another energized
lead out of the SPD. Power
to the load goes through
the SPD. Limited to 12A
maximum current.

A = L-G and N-G protection

(suggested for tall poles, or
when far from service entrance)

B = L-G protection only
C = L-N protection only

D = L-N and N-G protection

(for Delta systems)

G = L-L protection (for Delta
Systems)

1P

= One Pole, Single Phase

2P

= Two Pole, Split Phase

3Y
3C

= Three Pole Wye (Figure 2)
= B Phase Corner Grounded Delta

H = L-N, L-G & N-G protection

(powered L-N, see Figure 5)

(Available up to 20kA per mode
and 40kA N-G, Not available
with F or S options)

(powered L-L, see Figure 1)

(Figure 6)

= Three Pole Delta (Figure 4)
= Three Pole Hi-Leg Delta (Figure 3)

Figure 1
Hot (BLK)

Figure 2
Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)
Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

N

C

}

Neutral (WHT)
V

Phase C (BLK)
Ground (GRN)

WYE
3 Hots, 1 Neu, 1 Grnd

Examples:

(1 and 2 pole only)

Q

Please call APT at 800.237.4567 for
questions and application assistance

Figure 3
Phase A (BLK)
Phase B (ORNG)

}

V

Phase C (BLK)
Neutral (WHT)
Ground (GRN)

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

(1 and 2 pole only)

(not available with S option)

E = L-G and L-N protection
F = L-L and L-G protection

Power System
(see Figures)

}V
}V

ll

Modes of Protection Configuration

120V
127V
220V
240V
277V
347V
480V
600V

3D
3H

ll

Figure 4

}

V

= Call for Custom or Special
Builds

Figure 5
Phase A (BLK)
Phase B (BLK)
Phase C (BLK)
Ground (GRN)

DELTA & HRG WYE
3 Hots, 1 Grnd

}

Figure 6

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

LA480V1PA40S = L-G and N-G protection of 40kA for 480V true single phase (Meets FDOT Light Pole specs)
LA240V2PA40S = L-G and N-G protection of 40kA for 240/480V split phase (Meets FDOT Light Pole specs)
LA120V2PD20BFN = L-N and N-G protection of 20kA for 120/240V split phase with bracket, filter and thru-nipple wires
LA120V1PB40BFS = L-G protection of 40 kA for 120V true single phase with bracket, filter and series connection wires

Lead Configurations:

Mounting Configurations:

Standard configuration (blank) 12 AWG
leads exit the mouth of the SPD enclosure,
not the nipple. This ensures maximum
potting coverage around the leads for
environmental & moisture protection

Intended for mounting via nipple hub (1.05” OD,
needs appropriately sized hole)
B suffix option mounting bracket permits mounting on
flat surface or standard 35mm DIN-Rail

N suffix option moves 12 AWG leads to
exit thru the nipple area (unit is still potted)
S suffix option provides Series connection
leads thru the mouth (not available with N
option). This is also known as two-port,
Kelvin or feed-thru connection. Some
DOT light pole configurations require this.
Steady state current rating for S option is
12A. Not intended

12.30.14.lh #8691

Leads
into

Std. 3/4”-14
Nipple

DIN-Rail Mount
(rail not incl.)

Bracket Mount
for flat surfaces

Leads out of
SPD
Ground

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

43

Features
•
•
•
•
•

Primary Protector Kit for Coaxial Communication Lines
Includes SAVFFF UL 497C Listed Coaxial SPD
Includes two F to BNC connectors for BNC applications
Coaxial Gas Discharge Tube (GDT) Technology
Protects personnel and equipment from lightning and power
induced overvoltage surges

Performance Specifications
• Breakdown Voltage:
• Maximum Operating Voltage:
• Maximum Signal Current:
• Imax Surge Current Rating (8/20µs):
• Analog Frequency Range:
• SPD Insertion Loss:
• Response Time:
• Listing:

Intended Application
150V
100V
300mA
5kA
DC-1GHz
0.2 dB typical
<25ns
UL 497C

• Primary Protector at Service Entrance for life safety protection
from power line crosses and lightning.
• SAVFFF is UL 497C Listed (QVKC.E303380)
• Suitable for use in UL 96A Master Label Lightning Protection
System
• Per regulatory & industry convention, cascaded SPDs provide
maximum protection. An additional Secondary SPD is highly
recommended for critical electronics applications.

Physical Specifications

Design Features

•
•
•
•
•
•
•
•
•

• Designed, Manufactured & Tested consistent with:
– IEEE C62.43-2005
– IEEE C62.64-2009
– IEEE C62.41.1, C62.41.2 & C62.45
– IEC 61643-21
• Integral Fail-Short Mechanism

Intended for use within a weather-resistant enclosure
Relative Humidity Range: 0-95% non-condensing
Operating Temp: -40°C (-40°C) to +176°F (+80°C)
Weight: 0.2lbs (56g) (excluding BNC conn.)
Length: 3.0” (76mm long)
Metallic Case
Female F Connectors
Two (2) F-BNC connectors included
Pin-Grounded Shield Mode of Protection

Grounding
• Requires reliable ground
• SPD may be grounded via its legs with screw connections, or via
screw terminal that accepts up to 8 AWG (wire and attachment
screws not included)

Installation
• SPD is bidirectional; not direction-sensitive. Industry ‘Best
Practices’ recommend SPDs at both ends of cabling and/or
cascade protection.
• SPD must be connected to a reliable ground via screw-down
connection or ground wire (or both). Locate SPD such that
ground lead is as short and straight as possible. Inches matter!
Connect to a reliable ground, which should be the same ground
reference for power and Pan-Tilt-Zoom (if equipped).

Quality, Validation
•
•
•
•

• SPD redirects damaging energy to ground. If equipment/SPD
are atop tall pole, the long path to earth ground adds inductive
impedance and may affect performance
• This SPD intentionally short-circuit the line when failed. Remove
SPD, and test system. If system operates normally, replace
SPD.
• If signal quality decreases when SPD is installed, most
likely cause is a ground loop. Disconnect ground lead, and
test system. If system operates normally, contact APT for
BNCA10kA, which has ground isolation circuitry.

Advanced Protection Technologies
44

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

5 year warranty (longer optional)
UL 497C Listed (QVKC.E303380)
APT employs an ISO 9001:2008 Quality Management System
CE Mark: Yes

European Authorized Representative
Obelis s.a.
Boulevard Général Wahis 53
1030 Brussels, BELGIUM
Tel: +(32) 2. 732.59.54
Fax: +(32) 2. 732.60.03
3.10.15.lh #8619
E-Mail: mail@obelis.net

Features

The BNCA10kA is a premium SPD intended for Severe Service
at BNC coaxial connections for video equipment such as CCTV
cameras.

Top View

The BNCA10kA SPD features Three Stage Series Hybrid Surge
Protection
• Primary ‘Course’ Protection: Gas Discharge Tubes (GDTs)
• Series Current Limiting Component
• Secondary ‘Fine’ Protection: Silicon Avalanche Diodes (SADs)
Bottom View

Easy to Install, Din-Rail Mounting Bracket Included

Design Features

Performance Specifications
•
•
•
•
•

•
•
•
•
•
•

Nominal Operating Voltage: 5V
Maximum Operating Voltage: 8V
Maximum Signal Current: 300mA
Imax Surge Current Rating (8/20µs): 10kA
Clamping Voltage (Pin-Shield):
– 8/20µs, 5kA: 13.2V
– 10/700µs, 1kV: 14.7V
Digital Transmission Rate: ≤10Mbps
Analog Frequency Range: 0-10Mhz
Insertion Loss: ≤0.5dB@10MHz
Response Time: <1ns
Connection Type: BNC, 50 / 75 ohm
Discrete Modes of Protection: Pin-Shield, Shield-Ground

Quality & Validation
•
•
•
•
•

RoHS - compliant
5 year warranty (longer optional)
Individually Tested prior to shipment
APT employs an ISO 9001:2008 Quality Management System
CE Mark: Yes

• Designed, Manufactured & Tested consistent with:
– IEEE C62.43-2005
– IEEE C62.64-2009
– IEEE C62.41.1, C62.41.2 & C62.45
– IEEE Location Categories C, B and A
– NFPA 780 Lightning Protection
– IEC 61643-21

Shield - Ground Isolation
• The BNCA10kA includes separate protection modes for Pin
to Shield and Shield to Ground.
• This prevents SPD ground loops and possible signal
interference caused if a long run of cable references a
different ground than the head-end ground.

Physical Specifications
•
•
•
•
•
•

Intended for use within a weather-resistant enclosure
Relative Humidity Range: 0 - 95% non-condensing
Operating Temp: -40°C (-40°C) to +176°F (+80°C)
Weight: 0.25lbs (100g)
Dimensions: 3.35” (85mm long) x 1” square (25mm)
Pre-wired with 2’ (60cm) of #12 AWG ground conductor
(User to cut to shortest length possible)
• Anodized Extruded Aluminum Case; metallic bracket
• BNC gender changers are available

Installation:
• This is a directional, in-line series-connected SPD. PROTECTED end of SPD must be at equipment or camera end.
UNPROTECTED end must be at cable end. Industry ‘Best Practices’ recommend SPDs at both ends of cabling.
• Grounding: Locate SPD such that Ground lead is as short and straight as possible. Connect to a reliable ground, which should
be the same ground reference for power and Pan-Tilt-Zoom (if equipped). Trim Ground lead as appropriate. Inches matter! Do
not coil excess lead - cut off excess lead. Crimp-attach included wire terminal and connect to reliable ground. Din-Rail bracket
does not electrically ground this SPD. SPD attachment to Din-Rail is not mandatory.
• All applicable Code(s) and regulation(s) must be followed.
• If SPD problems are suspected, remove SPD and test system. If system operates normally, replace SPD.

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

European Authorized Representative
Obelis s.a.
Boulevard Général Wahis 53
1030 Brussels, BELGIUM
Tel: +(32) 2. 732.59.54
Fax: +(32) 2. 732.60.03
3.10.15.lh #8540
E-Mail: mail@obelis.net

45

Protecting Coax Cables from Surges
Most surges on coax cable originate on the shield, not the pin.
• In a coax application, the pin is protected by the shield. For
example, lightning induces onto the shield, as would accidental
contact with a power line. Consequently, excessive emphasis on
protecting the pin may be misguided.
• According to IEEE C62.43 research:
– Surge current injected equally onto the pin and shield will
propagate unequally. Due to inductance, the shield will carry
about four times more surge current than the pin.
• “Surge propagation speed is faster on the shield than the pin,
leading to voltage differentials between pin and shield on long
runs of coax cable.”
• Coax surge protection is different than AC power surge protection:
– Focus is on the grounded shield conductor as opposed to the
‘active’ conductor. (On AC systems, focus is usually on the
energized conductor.)
– MOV suppression components may degrade signal quality due to
higher capacitance.
Primary & Secondary SPDs are intended for use together in a
cascade arrangement.
• Irony: People routinely protect AC circuits with sizeable cascade
SPDs, but do not do it with coax, despite smaller SPDs and
sometimes a harsher environment. Cascade SPDs as appropriate.

Concept of Cascade Protection
Secondary SPD
(UL 497A) with better
clamping performance
to better protect

UL 497 Listing categories are often misunderstood.
• UL has two generalized categories for Communication SPDs:
Primary and Secondary Protectors.
– Primary Protectors: e.g., UL 497, UL 497C. “Primary protectors
are intended to suppress abnormal overvoltage conditions
that may exist on the circuit due to accidental contact with
electric light or power conductors operating at or over 300 V to
ground…”.
Translation: These are more intended for life safety protection
from power line crosses & lightning, and may not clamp low
enough to protect sensitive electronics.
– Secondary Protectors: e.g., UL 497A. “Secondary protectors are
intended to suppress abnormal voltage and/or current conditions
that bypass the primary protector.”
Translation: Secondary Protectors offer better clamping
protection for sensitive electronics.
• Hiccup?: There are single SPDs having the robust componentry
of Primary SPDs and the lower and better clamping
performance of Secondary SPDs. However, by quirk, the lower
clamping voltage and better performance prevents them from
passing UL’s testing as a Primary Protector. The resulting
confusion factor is one reason why various manufacturers do
not UL List coax SPDs. Note that UL 96A Lightning Protection
applications mandate a UL 497C unit. Good practice suggests
an additional Secondary Protector to protect sensitive
electronics.

Primary SPD
(UL 497C) for life safety
purposes to protect
against Power line cross
or direct stroke

SECONDARY SPD

SPD

PRIMARY SPD

SPD

BUILDING
SPD

SPD

COAX CABLE

Hiccup: Ground Loops and resulting signal loss
• Coax cable shields are grounded at their ‘head-end’. The shield is
not supposed to be grounded further downstream. Reason: If the
shield is grounded at multiple locations, and those grounds are at
different potentials, then current will ‘loop’ through the shield as the
ground potentials attempt to equalize themselves. This is called a
Ground Loop, and can/will cause signal decay.

• Away from the ‘head-end’, if the SPD’s shield protection is directly
connected to ground, it can/will cause a ground loop. Different SPD
technology with ground isolation is required to prevent this. The
APT SPD will not cause ground loops.

Avoiding Ground Loops

COMMUNICATION
EQUIPMENT

SPD

SPD

COAX CABLE

Head-End Coax
Shield is Referenced
to Ground

46

If these two grounds have a voltage difference, and
the coax Shield can complete the circuit, then current
will flow through the Shield creating a Ground Loop.

Advanced Protection Technologies, Inc.
14550 58th Street North, Clearwater, Florida 33760

If remote SPD shield is ‘hard-grounded’ and there
is a voltage between the two grounds, then a
Ground Loop is likely. An SPD with ground
isolating qualities is required (APT BNCA10kA).

(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com
3.10.15.lh

Low Voltage/
Communication SPDs

DIN-Rail, Series Connected

Premium SPDs intended for use on a wide range of low voltage applications
inside appropriate enclosures, including high speed communication circuits.
Terminals are finger-safe.
• SPDs include three stage high-energy surge suppression in a Pi (π) configuration:
– 1st Stage: Parallel-connected Gas Discharge Tubes
– 2nd Stage: Series-connected impedance
– 3rd Stage: Parallel-connected Transorbs
• Each SPD Protects Two (2) Pairs of Wire
• UL 497B Recognized UL File: QVGQ.E244864
• Circuit schematic printed on side of SPD
• Dual Grounding:
– Ground Wire Lug (recommended)
– Through DIN-Rail Connection
Two or Four Wire Data Lines such as
Camera PTZ or Vehicle Detectors

Application

RS-232

RS423

Model Number

RS-422

Low Voltage Power Protection

RS-485

12VDC

24VDC

24VAC

30VDC

48VDC

60VDC

RS232/D1

RS423/D1

RS422/D1

RS485/D1

12VDC/D1

24VDC/D1

24VAC/D1

30VDC/D1

48VDC/D1

60VDC/D1

Protocol Operating Voltage

+/- 25V

+/- 6V

-0.25V – +6V

-7V – +12V

12VDC

24VDC

24VAC

48VDC

48VDC

60VDC

SPD Max Cont Op Volt (MCOV)

28VDC

15VDC

15VDC

15VDC

15VDC

28VDC

36VAC

52VDC

52VDC

64VDC

<46V

<27V

<27V

<27V

<27V

<46V

<60VAC

<85V

<85V

<105V

Typical Breakdown Voltage (VDC)

33V

18V

18V

18V

18V

33V

32VAC

61V

61V

75V

Maximum Leakage Current (µA)

5µA

5µA

5µA

5µA

5µA

5µA

5µA

5µA

5µA

5µA

Clamping Voltage (VDC)

Other Applications

Easy to Install

Specifications & Features

Unprotected side
Install such that surge
hits this side

• Other Low Voltage: See D60401 Series data sheets
• BNC: See BNCA10KA or BNCB5KA data sheets
• 120V: See AC DIN-Rail data sheets

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Surge Current Rating: 15kA
Rated Operating Current IL (mA): 800mA
Number Wires Protected: up to 4 wires (2 pair)
Wire Size: 14 AWG - 26 AWG
Response Time (ns): <1 ns
Mounting Type: 35mm DIN-Rail
Temperature Rating: -40°F to 185°F (-40°C to 85°C)
Enclosure Material: Thermoplastic UL 94-V0
Enclosure: NEMA 1 (IP 20)
Dimensions: 3.9” x 2.6” x 0.47” (99mm x 65mm x 12mm)
Weight: 4.75oz (135g)
Thermal Protection: Yes
Color: Gray
IEEE C62.41-2002, Cat C, B & A: Yes
IEC 61643-21Compliant: Yes
IEC Max. Discharge Current Imax (8x20µs): 15kA
IEC Max. Discharge Current In (8x20µs): 10kA
IEC Max. Lightning Pulse Iimp (10x350µs): 2.5kA
CE Mark: Yes
Warranty: 2 Year

In-line series connected SPD. Normal signal goes through this unit.

Ground Lug internally connects to tab contacting DIN-Rail. We
recommend cable connection from Ground Lug to Verified Ground.
0.47 in.
(12 mm)

Dimensions

2.56 in.
(65 mm)

Weight:
4.75oz (135g)

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

Protected side
Camera, MVDS,
widget, etc.

.
3.9 inm
80 m

European Authorized Representative
Obelis s.a.
Boulevard Général Wahis 53
1030 Brussels, BELGIUM
Tel: +(32) 2. 732.59.54
Fax: +(32) 2. 732.60.03
E-Mail: mail@obelis.net
3.10.15 #8632

47

D60401, S-suffix

• These premium SPDs are intended for use on a wide range of low
voltage applications inside appropriate enclosures, including high
speed communication circuits. Terminals are finger-safe.
• D60401 SPDs include three stage surge suppression in a Pi (π)
configuration:
– 1st Stage: Parallel-connected Gas Discharge Tubes
– 2nd Stage: Series-connected resistor (includes inductor on ‘S’ models)

D60401, B-suffix

– 3rd Stage: Parallel - connected Transorbs
• Two D60401 SPD families are offered:
– S-suffix: ‘Standard’ - for Analog, DC voltage, or low-frequency data to
600kHz
– B-suffix: ‘Bandwidth’ - for Digital or High-Frequency Data up to 35MHz

Features

Model Number Configurator

• Surge Current Rating: 15kA
• UL 96A Lightning Protection Master Label: Yes
• Rated Operating Current IL (mA): 800mA (1000mA for
B-suffix models)
• Number Wires Protected: up to 4 wires (2 pair)
• Wire Size: 14 AWG - 26 AWG
• Response Time (ns): <1 ns
• Mounting Type: 35mm DIN-Rail
• Temperature Rating: -40°F to 185°F (-40°C to 85°C)
• Enclosure Material: Thermoplastic UL 94-V0
• Enslosure: NEMA 1 (IP 20)
• Dimensions: 3.9” x 2.6” x 0.47” (99mm x 65mm x 12mm)
• Weight: 4.75oz (135g)
• Thermal Protection: Yes
• Color: Gray
• UL 497B Listed: UL File QVGQ.E244864
• CE Mark: Yes
• IEEE C62.41-2002, Cat C, B & A: Yes
• IEC 61643-21 Compliant: Yes
• IEC Max. Discharge Current Imax (8x20µs): 15kA
• IEC Max. Discharge Current In (8x20µs): 10kA
• IEC Max. Lightning Pulse Iimp (10x350µs): 2.5kA
• Warranty: 2 Year

D60401Voltage Codes
005
012
024
048
060

=
=
=
=
=

5VDC (3.5VAC) S (Standard) = Analog, DC
12VDC (8.5VAC) B (Bandwidth) = Digital up to 35MHz
24VDC (17VAC)
48VDC (34VAC)
60VDC (42VAC)

Suggested Applications
Protocol

Nominal
Voltage

Suggested SPD

RS-232

+/- 25V

D60401-024S

RS-423

+/- 6V

D60401-012S

RS-422

-0.25V - +6V

D60401-012B

RS-485

-7V - + 12V

D60401-012B

Modbus (usually RS-485)

D60401-012B

Irrigation/Sprinkler Valves

24VAC
D60401-048S
Need to determine.
Default:
Could be 24VDC,
D60401-048S
12VDC, etc.
Default:
Can’t Find Out?
D60401-048S

4 - 20mA
Don’t know?

Voltage Codes

Nominal Operating Voltage (VDC / VAC)
MCOV (VDC)
Clamping Voltage (VDC)
Voltage Breakdown (Min/Max VDC)
IEC Voltage Protection Level
(Up @ 1kV/µs, VDC)
Maximum Leakage Current (µA)

"005"
5 / 3.5
7
<12
7/9

"012"
12 / 8.5
15
<27
16/20

"024"
24 / 17
28
<46
29.5/36.5

"048"
48 / 34
52
<85
55.5/68.5

"060"
60 / 42
64
<105
67.5/82.5

12

27

28

52

64

200

5

5

5

5

Advanced Protection Technologies
48

lll l

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

European Authorized Representative
Obelis s.a.
Boulevard Général Wahis 53
1030 Brussels, BELGIUM
Tel: +(32) 2. 732.59.54
Fax: +(32) 2. 732.60.03
E-Mail: mail@obelis.net

Dimensions
0.47 in.
(12 mm)

2.56 in.
(65 mm)

3.9 in.
80 mm

Information
Finger Safe Terminals

Unprotected Side

Protected Side

Install such that
surge hits this side

VALUABLE EQUIPMENT SIDE

Ground lug tab

Internally connected to DIN-Rail

– Series connected (Power/Data goes through SPD)
– Protects up to 4 wires (2 pairs of 2 wires)
DIN-Rail not included

Typical 4-Wire Installation

Protected Load Side

Only 2 wires?
– Use either top or bottom sets.
DIN-Rail not included

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com
3.10.15.lh #8384
49

MVF - Medium Voltage

Surge Protective Device + Three Phase Fuse Box
SPD
Advanced Protection Technologies
Clearwater, Florida USA
www.aptsurge.com
#8518

DANGER
DANGER

HIGH VOLTAGE
1500VAC

KEEP AWAY

DANGER

CONTAINS NO USER
SERVICEABLE PARTS

ALTO VOLTAJE

FAILURE TO KEEP AWAY WILL RESULT
IN DEATH OR SERIOUS INJUR Y

The MVF consists of a Medium Voltage parallel SPD and stand-alone,
three phase fuse box. The MVF is designed for Oil and Gas, Water/
Wastewater, Chemical, Large Industrial and Heavy Duty Applications
at Service Entrance, Distribution locations as well as Individual
Equipment. The Three Phase Fuse Box component of the MVF is
REQUIRED to be installed on the line side of, and in-line with, the
Medium Voltage SPD component as dedicated overcurrent protection
and to safely disconnect the SPD from the electrical system in the
event of an SPD failure.

MVF SPD Component Design Features

Advanced Protection Technologies
Clearwater, Florida USA
www.aptsurge.com
#8518

•
•
•
•
•
•
•
•
•

HIGH VOLTAGE

FUSE BOX

•
•
•

•
Represents a typical installation of an MVF

•
•

Low clamping voltage for maximum equipment protection
Parallel design MOV suppression allows installation flexibility
Bi-directional operation for positive and negative surges
Solid state, fully automatic action and reset
Large-Block, 40mm, MOVs
Solid State Bidirectional Operation
Intended for High Energy applications including all IEEE C62.41.2
Category A, B and C High Applications
All Mode (6 Modes) dedicated (A-B, B-C, A-C, A-G, B-G, C-G)
Pre-wired with 2’ (0.61 Meters) #6 stranded leads for connection
to Fuse Box
Includes internally threaded conduit hub 1 1/4”
External Mounting Flanges
Inorganic silica particle encapsulation
– Noncombustible at extreme temperature
– Superior gaseous expansion tolerance
Double insulated against ground fault or arcing with separate
polypropylene and polyethylene layers
Elastomeric Ceramgard®potting protects against environmental
contaminants
High Voltage warning labels standard

MVF SPD Component Specifications
•
•
•
•
•
•
•
•
•
•

Surge Current Rating: 120kA per phase
Proven ‘large block’ 40mm MOV Technology
Protection Modes: All Modes L-L and L-G (Normal mode & Common mode)
Directly connected MOV suppression elements
NEMA 4 (IP66) Heavy Gauge Steel Enclosure
Dimensions: 31cm x 31cm x 15.5cm (12” x 12” x 6”)
Weight: 29.5kg (65 Lbs)
Relative Humidity Range: 0 – 95% Non-Condensing
Operating Frequency: 50Hz, 60Hz
Operating Temperature: -40°C (-40°F) to +85°C (+185°F)

MVF SPD Quality
• Seven (7) Year Warranty on SPD
• Every unit Burn-in tested prior to shipment
• ANSI/IEEE C62.11

Advanced Protection Technologies
50

14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

MVF - Medium Voltage

Surge Protective Device + Three Phase Fuse Box
Optional Monitoring Package

• Allows for on-site or remote monitoring of suppression circuits
– Indicator lights for each phase
– Dry Contacts for each phase
– Available on 120kA models only

Fuse Box Component Design Features

SPD WITH OPTIONAL MONITORING

• Designed to be installed in front of and in-line with APT’s MV
Medium Voltage SPD as part of the MVF.
• NEMA 4X Polycarbonate enclosure with stainless steel lockable latches.
• All connecting wires included
– 2.4m (8 ft) of #6 AWG, 25kV wire each (3 Phase, 1 Ground).
– Additional 6kV sleeving on each wire for added safety.
• 2 – 1 ¼ ” threaded hubs included to enter and exit enclosure.
• Includes 3 Bussman model 5.5CAVE (5.5kV, 15A).
• Includes 6” of conduit for SPD to Fuse Box connection.

Fuse Box Component Specifications
•
•
•
•
•
•
•
•

Enclosure Dimensions: 457.2mm x 406.4mm x 254mm (18” x 16” x 10”)
Weight: 15.9 kg (35 lbs)
Maximum Voltage: 5500VAC
Maximum Current: 15 Amp
Torque: 80 Inch-Lbs
Relative Humidity Range: 0 – 95% Non-Condensing
Operating Frequency: 50Hz, 60Hz
Operating Temperature: -40°C (-40°F) to +85°C (+185°F)

FUSE BOX

MVF

41 12

04

D

VOLTAGE CODES
10

=

1000V

15

=

1500V

20

=

2000V

25

=

2500V

30

=

3000V

36

=

3600V

41

=

4160V

AVAILABLE OPTIONS

D

=

Monitoring Package:
Indicator lights per
phase & dry contacts
per phase

ENCLOSURE RATINGS

04

=

NEMA 4

SURGE CURRENT RATINGS
12

=

120kA per phase

24

=

240kA per phase

Note: Monitoring Package available only on
120kA per phase models

7.5.16.lh RevF

Advanced Protection Technologies
14550 58th Street North · Clearwater, Florida 33760
(800) 237-4567 · (727) 535-6339 · Fax (727) 539-8955
www.aptsurge.com · info@aptsurge.com

51

What Electrical System Is It?
•
•
•
•

Based on secondary side of upstream transformer, NOT by how load is connected.
Most SPD/TVSS order errors are misunderstandings related to grounding or neutrals.
What
Electrical
System
Is It?
Grounded system means that the system
is referenced
toElectrical
ground,
NOT
that
there
Based on secondary sideWhat
of upstream
transformer, NOTSystem
by how load is connected
Is
It? is a safety ground.
Most
SPD/TVSS
misorders
are
misunderstandings
related
to
grounding
or neutrals
What Electrical System
By convention, ground wires are notBased
‘counted’
of
the
wires
(3-wire,
4-wire,
What
Electrical
System
It? etc.).
on secondaryas
sideone
of upstream
transformer,
NOT
by
how load
isIs
connected
Grounded system means that the system is referenced to ground, NOT that there is a safety ground

Based
secondary
side of upstream transformer, NOT by how lo
on secondary
side
ofmisunderstandings
upstream
transformer,
NOT
howon
load
connected
MostBased
SPD/TVSS
misorders
areare
toby
grounding
orisneutrals
By
convention,
ground wires
not ‘counted’
as one related
of the
wires
(3-wire,
4-wire,
etc.)
Most
SPD/TVSS
misorders
are misunderstandings
related to grou
Most SPD/TVSS
misorders
are
misunderstandings
to grounding
neutrals
Grounded
system means
that the
system
is referenced related
to ground,
NOT that or
there
is a safety
ground
Grounded
system
means
that the system is referenced to ground,
Grounded
means
thatnot
the‘counted’
system isas
to
ground,
NOT4-wire,
that there
A are
Breferenced
B system
By convention,
ground
wires
one
of
the
wires
etc.)
A (3-wire,
Bis a safety ground
3-phase 4-wire Grounded Wye

A
3-phase 4-wire Grounded Wye
By wires
convention,
ground
wires
By convention, ground wires are not ‘counted’ as one of the
(3-wire,
4-wire,
etc.)are not ‘counted’ as one of the wires
Neutral bonded to ground. Neutral pulled into
NeutralA bondedWhat
to ground.Electrical
Neutral
NOT pulled
into
A
B
B
System
Is
A
N
AIt? B
B
A
B
N
A
B
A
B
N
B
facility. Common system configurations.
facility. Common
system configurations
MCC,
Based on secondary
side
of upstream
transformer, at
NOT
byAhow load is connected
What Electrical
System
Is It?
V = 120V (208Y/120V) APT ‘2’ Based on secondary side of upstream transformer,
Most SPD/TVSS
misorders
are
misunderstandings related to grounding or neutrals
andiswater
treatment.
NOTpumping
by how
load
connected
N
N
N
V
V
V
N
related
to 120V
grounding
or neutrals
N G to ground, NOT
Grounded
system
means
that
theNsystem
thatN there is a safety ground
G (208Y/120V)
G misunderstandings
V = 277V (48OY/277V) APT ‘4’ Most SPD/TVSS misorders are
V=
APT
‘2’is referenced
N
Grounded system means that the systemBy
is referenced
to ground,
NOT
thatare
there
is a‘counted’
safety ground
What Electrical S
convention,
ground
wires
not
as
one
of
the
wires
(3-wire,
4-wire,
etc.)
C
C
C
V = 347V (600Y/347V) APT ‘8’ By convention, ground wires are not ‘counted’
277V
(48OY/277V)
APT ‘4’
as one of V
the=wires
(3-wire,
4-wire, etc.)
Based
on secondary
side of upstream transformer, NO
3-phase 4-wire Grounded Wye
3-phase 4-wire
Ungrounded
Wye
3-phase 4-wire Grounded Wye
bonded to ground
Neutral(600Y/347V)
bonded to ground APT
Neutral
ground G V misorders are misunderstandings
V = 127V (220Y/127V) APT ‘21 ‘ (non-USA)
V NOT bonded
V
Mostto SPD/TVSS
rela
V
V = 347V
G Neutral
G
V B
V
A pulled into facilityVG V‘8’
B Neutral mayGor may
A
G not beA
Neutral
NOT
pulled into facility
B is referenced
G pulled into facility
ANeutral
B
A
Grounded
system means that the system
AG system configuration at MCC, B
Common system configuration
Rare system configuration; Error/miss-wire?
Common
V = 220V (38OY/220V)
APT ‘7’ (non-USA)B
V = 127V
(220Y/127V)
APT
‘21 ‘Electrical
(non-USA)
C
Cwires are not ‘counted’ as one o
C C Is It?
What
System
C
By
convention,
ground
V = 120V C(208Y/120V)
APT
‘2’
Note
NEC
285.3(2),
pumping
and
water
treatment
C
C
V = 277V (480Y/277V) APT ‘4’
V = 120V
(208Y/120V)
Rare
- Call
V on
= 120V
(208Y/120V)
APT
‘2’
3-phase
4-wire
Grounded
Wye
3
3-phase
4-wire
secondary
side
of
upstream
transformer,
NOT
by
how
load
is connected
V Based
= 220V
(38OY/220V)
APT
‘7’Wye
(non-USA)
3-phase
4-wire
Grounded
Wye
3-phase
4-wire
Grounded
Wye
3-phase
4-wire
Ungrounded
WyeGrounded Wye
3-phase
4-wire
Grounded
Wye
4-wire
Ungrounded
4-wire
Grounded
V = 347V
(600Y/347V)
APT ‘8’
(480Y/277V)
APTNeutral
‘5’
V =3-phase
277V (480Y/277V)
APT ‘4’bonded
Neutral
to ground V = 277V 3-phase
bonded toWye
ground
N

N

Neutral
bonded
to ground
Neutral
bonded
to
ground
Neutral
NOTto
bonded
A
A
B to
SPD/TVSS
misorders
are
misunderstandings
grounding
neutrals
V = 127V
(220Y/127V)
(600Y/347V)
APT
‘9’ground
V =Neutral
347V
(600Y/347V)
APTN
‘8’
Neutral
bonded
toNground APT ‘21’ (non-USA) Most
bonded
to ground
Neutral
NOT
bonded
to or
ground
Neutral
into facility V = 347Vrelated
Neutral
NOT
pulled into facility
Npulled
N
N
Neutral
pulled
into facility
Neutral
NOT
pulled
into Common
facility
Neutral
may
or may
not
be
into into
facility
V = 220V
(380Y/220V)
V = 127V
(220Y/127V)
(non-USA)
V =Neutral
127V
(220Y/127V)
APT
‘21’the
(non-USA)
Neutral
pulled
into facility APT ‘7’ (non-USA) Grounded
NOT
pulled
into
facility
Neutral
may
orCall
may
notpulled
be system
pulled
facility
system
means
that
system
is referenced
to ground,
NOT
that
there
is a
safetyatground
system
configuration
Common
configuration
MCC,

What Electrical System Is It?

B

N
R

V = 220V
V =Common
220Vsystem
(380Y/220V)
APT ‘7’at(non-USA)
(380Y/220V)
Call (non-USA)
Common
system
configuration
RareRare
system
configuration;
Error/miss-wire?
Common
configuration
Electrical
System
Common
system
configuration Is It? 3-phase
system
configuration;
Error/miss-wire?
system
configuration
at MCC,
Resistive or Impedance GroundedWhat
Wye
4-wire
Ungrounded
Wye
V = 120V
(208Y/120V)
‘2’
N
pumping
and
wateretc.)
treatment
By convention,
ground
wires
areMCC,
not
‘counted’
oneload
of the
(3-wire,
4-wire,
Based
on secondary
side
ofand
upstream
NOT APT
byashow
iswires
connected
V = 120V
(208Y/120V)
APT
‘2’
NoteNote
NECNEC
285.3(2),
water
treatment
V = 120V
(208Y/120V)
APT
pumping
and water
treatment
Vtransformer,
= 277V (480Y/277V)
APT
‘4’
V
V = 120V (208Y/120V) APT ‘2’N
B‘2’ is connected pumping
Based on secondary side of upstream
transformer,
NOT by
how
load
A 285.3(2),
N
V
=
277V
(480Y/277V)
APT
‘4’
V
=
120V
(208Y/120V)
Rare
Call
V
=
120V
(208Y/120V)
APT
‘2’
Neutral bonded to ground
via
grounding
resistor.
Neutral
NOT
bonded
to
ground.
Neutral
mayor
V
=
277V
(480Y/277V)
APT
‘4’
V
=
120V
(208Y/120V)
Rare
Call
V
=
120V
(208Y/120V)
APT
‘2’
V
=
347V
(600Y/347V)
APT
‘8’
V
V
=
277V
(480Y/277V)
APT
‘4’
A
Most
SPD/TVSS
misorders
are
misunderstandings
related
to
grounding
or
neutrals
V
V
Most SPD/TVSS V
misorders are misunderstandings
related to A
grounding
or neutrals
A
G
G
B = 277V
B = (non-USA)
V = 347V
(600Y/347V)
APT ‘8’
V
277V
(480Y/277V)
APTAPT
‘5’(600Y/347V)
V = 277V
(480Y/277V)
APT
‘4’ (220Y/127V)
B
VG
= 347V
(600Y/347V)
APT
‘8’
V = 277V
(480Y/277V)
‘5’
VA=
127V
APT ‘21’
V
V
(480Y/277V)
APT
‘4’ V
VA= 347V
APT
‘8’
V
V
G
Grounded
system
means
that
the
system
is
referenced
to
ground,
NOT
that
there
is
a
safety
ground
Grounded
system
means
that
the
system
is
referenced
to
ground,
NOT
that
there
is
a
safety
ground
V
G
GV = 127V
Neutral may, or may not, be pulled
into
facility.
may
not
be
pulled
into
facility.
Rare
system
V
=
220V
(380Y/220V)
APT
‘7’
(non-USA)
V
V
=
127V
(220Y/127V)
APT
‘21’
(non-USA)
(220Y/127V)
APT(non-USA)
‘21’ (non-USA)
V
=
347V
(600Y/347V)
APT
‘9’
V
= 347V
(600Y/347V)
APT
‘8’
V = 127V
(220Y/127V)
APT ‘21’
V
=
347V
(600Y/347V)
APT
‘9’
V
= 347V
(600Y/347V)
APT
‘8’
V
C
By convention,
ground wires are not
as (380Y/220V)
oneCof the
(3-wire,
4-wire,
etc.)
Bywires
convention,
ground
are (220Y/127V)
notC ‘counted’
of the wires
4-wire,
etc.)
V
V = 220V
(380Y/220V)
V = 220V
APT(non-USA)
‘7’ (non-USA)
V =(3-wire,
127V
(220Y/127V)
Call
(non-USA) APT ‘7’ (non-USA)
V = 127V
‘21’one
(non-USA)
V =‘counted’
220V
(380Y/220V)
APT
‘7’
V = 127V
(220Y/127V)
Call
(non-USA)
V = wires
127V
(220Y/127V)
APT APT
‘21’ as
(non-USA)
N
Becoming popular3-phase
system4-wire
on high-tech
applications.
configuration;
Error/miss-wire?.
Note
NEC
285.3(2).
C
V(380Y/220V)
V
N Ungrounded
CAPT APT
C Grounded Wye
Grounded Wye
3-phase
4-wire
3-phase 4-wire
V = 220V
V = 220V
(380Y/220V)
‘7’ Wye
(non-USA)
G
G
V = 220V
V = 220V
(380Y/220V)
‘7’ (non-USA)
(380Y/220V)
Call Call
(non-USA)
N(non-USA)
B
Neutral bonded to ground
Neutral bonded
to ground
Neutral
A
B
N
A
B NOT bonded to ground
R B Grounded
A
3-phase
4-wire
3-phase
4-wire Ungrounded
Grounded
Wye
V = 120V (208Y
/120V)
Rare
Call APT A
V =N120V
(208Y/120V)
- Call
BB
ANeutral
A 3-phase
B APT
C Wye
C
B Wye
A
B
Neutral
pulled
into -facility
NOT pulled
into facility
Neutral
may or 4-wire
mayAnotRare
be
pulled
into
facility
A A
V
G
Ato ground
Neutral
bonded
to ground
Neutral
bonded
Neutral NOT bonded
to ground
A
Common system configuration
Rare
system
configuration;
Error/miss-wire?
Common
system
configuration
at
MCC,
A
3-phase
4-wire
Grounded
Wye
3-phase
4-wire Grounded Wye
A
V = 277V (48OY/277V)
APT
‘5’
V
=
277V
(48OY/277V)
APT
‘5’
G
V
Neutral
pulled
intowater
facility
Neutral
NOT pulled into facility
Neutral may orVmay
not bonded
be pulled
into facility
V = 120V (208Y/120V) APT ‘2’
Note
NEC 285.3(2),
and
treatment
Neutral bonded to ground
Neutral
to ground
N pumping
G
C
N
V = 277V APT
(480Y/277V)
120V (208Y/120V)
Rare
-VCallNeutral
V = 120V
(208Y/120V)
B GAPT
V N V =Common
V into facility
VError/miss-wire?
pulled
Neutral NOT
pulled into facility
G V configuration;
Common
system
configuration
Rare system
system
configuration
at MCC,
GAPT ‘2’
V = 347V (600Y/347V)
‘9’ APT ‘4’
V = 347V
(600Y/347V)
V ‘9’
N
Single-Phase
N
V = 347V (600Y/347V) APT ‘8’
V
=
277V
(480Y/277V)
APT
‘5’
V
=
277V
(480Y/277V)
APT
‘4’
Common system configuration Note NEC 285.3(2),
Common system configuration at MCC,
V = 120V
(208Y/120V)
APT
‘2’
pumping
and water treatment
N
N
Resistive
or
Impedance
Grounded
Wye
Split-Phase
‘Single-Phase’
Verify
where
Neutral
and
Ground
are!
V = 127V (220Y/127V) APT ‘21’ (non-USA)
V = (220Y/127V)
347V (600Y/347V)
‘9’C (non-USA)
V = 347V (600Y/347V) APT ‘8’
NCall
C pumping and water treatment
V = 120V (208Y/120V) APT ‘2’ N N
C
V = 127V
APT
RAPT
N
V = 277V
(480Y/277V)
‘4’
V = of120V
V bonded
= 120V
(208Y/120V)
APT
‘2’ Often for one leg or one piece
Neutral
bonded to groundAPT
via grounding
resistor
Neutral
to ground
equip. (208Y/120V) Rare - Call
V = 277V (480Y/277V) APT ‘4’
V = 120V (208Y/120V) APT ‘2’
V = 220V (380Y/220V) APT ‘7’ (non-USA)
V = 127V (220Y/127V) Call (non-USA)
V = 127V (220Y/127V) APT ‘21’ (non-USA)
Neutral
not, APT
be pulled
into facility
Neutral
usually
pulled(480Y/277V)
into
facility 4-wire
Neutral
bonded to groundV =3-phase
4-wire
Grounded Wye
4-wireVUngrounded
Wye APT ‘4’
V
V may, or may 3-phase
3-phase
Grounded
Wye
R(600Y/347V)
V = 347V
‘8’
277V (480Y/277V)
‘5’
= 277V
APT
V (600Y/347V)
G
G
V
= ‘4’
347V
APT ‘8’
= 277V APT
(480Y/277V)
VV =V
220V
VBecoming
= 220V
(380Y/220V)
APT
‘7’ G(non-USA)
(380Y/220V)
CallAPT
(non-USA)
V
=
220V
(38OY/220V)
Call
(non-USA)
R
popular
system
on
high-tech
Very,
very
Common
Less common than perceived!Neutral NOT bonded to ground
Neutral
bonded
to
ground
Neutral
bonded
to
ground
V = 127V
(220Y/127V)
APT
‘21’
(non-USA)
V
=
347V
(600Y/347V)
‘9’
V
=
347V
(600Y/347V)
APT
V = ‘8’
127V
(220Y/127V)
APT G
‘21’
(non-USA)
V = 347V APT
(600Y/347V)
APT ‘8’
G
V
V
=
120V
(208Y/120V)
Rare
Call
V
=
120V
(120/240V)
APT
‘1’
V
=
120V
APT
‘11’
C
Neutral pulled into facility
Neutral
NOT pulledV into
facility
Neutral may or may
not
be pulled
into facility
C
C
B
V
G
=
220V
(380Y/220V)
APT
‘7’
(non-USA)
V
=
127V
(220Y/127V)
APT ‘21’ (nonSplit-Phase ‘Single-Phase’
G
A
V ‘5’
V CAPT
V B Error/miss-wire?
V = 220V
(380Y/220V)
APT
‘7’ (non-USA)
127V
(220Y/127V)
Call (non-USA)
V
127V
(220Y/127V)
‘21’V(non-USA)
(480Y/277V)
APT
V =G
240V
(240/480V)
Rare - Call
= 240V
APT ‘12’ G V =Rare
GV = 277V
G =Wye
Common
system configuration
system configuration;
Common
system
configuration
at MCC,
A APT ‘9’
3-phase 4-wire
3-phase
4-wire Ungrounded
3-phase 4-wire Grounded
V = 220V (380Y/220V) APT ‘7’ (non(600Y/347V)
V
= 127V
(127/254V)
APT ‘15’ (non-USA)
V(non-USA)
= 277V APT ‘16’
A Grounded Wye
G
GV = 347VWye
V
=
220V
V
=
220V
(380Y/220V)
APT
‘7’
(380Y/220V)
Call
(non-USA)
Sin
V = 120V Neutral
(208Y/120V)
APTto‘2’
Note NEC 285.3(2),
pumping and water treatment
Single-Phase
C
Neutral bonded
to ground Neutral usually pulled
Neutral bonded
NOT bonded
ground
Neutral bonded
to ground.
B
V =Grounded
480V APT ‘17’
Call – almost
always different
Gto ground C C
Impedance
Wye
‘Single-Phase’
Ver
V = 277V Neutral
(480Y/277V)
APT
=C120V (208Y/120V)
Rare - Call
V = 120V Vor
(208Y/120V)
APT
‘2’ Single-Phase
B V Split-Phase
Neutral pulled into facility
Neutral NOT pulled into facility
may or may
not‘4’
be pulled into facilityCBResistive
V = 127V
APT ‘13’ (non-USA)
V
Neutral
bonded
to
ground
via
grounding
resistor
Neutral
bonded
to
ground
Oft
B
A
V
=
347V
(600Y/347V)
APT
‘8’
V
=
277V
(480Y/277V)
APT
‘5’
V
=
277V
(480Y/277V)
APT
‘4’
Verify
where
neutral
and
ground
are!
Often
this
is
used
Common
system
configuration
Rare
system
configuration;
Error/miss-wire?
Common
system
configuration
at
MCC,
A Wye
Single-Phase
into facility.
Very, very Common.
V = 220V
APT3-phase
‘12’
(non-USA)
Resistive
or Impedance
Grounded
Wye
Split-Phase
‘Single-Phase’
A
Verify
where
Neutral
andUngrounded
Ground are!
3-phase
4-wire
Grounded
Wye
4-wire
3-phase
4-wire
Grounded
Neutral
may,
orWye
may not, be
pulled
facility
usually
pulled into
facility
Neu
V = 120V (208Y/120V) APT ‘2’
Note
NEC
285.3(2),
pumping and
water treatment
V Grounded
= 127V
(220Y/127V)
APTSplit-Phase
‘21’
(non-USA)
V Neutral
=one
347V
(600Y/347V)
APT
‘9’
V
= 347V
(600Y/347V)
APT
‘8’ into
A
Resistive
or
Impedance
Wye
‘Single-Phase’
Verify
where
Neutral
and
Ground
are!
Neutral
bonded
to
ground
via
grounding
resistor
Neutral
bonded
to
ground
Often
for
one
leg
or
piece
of
equip.
N
A
N 220V V (380Y/220V)
Neutral bonded
bonded
toBecoming
ground
Neutral
NOTVbonded
to ground
popular
systemNeutral
on
high-tech
Very,
very
Common
V = (120/240V)
277V (480Y/277V)APT
APT ‘1’
‘4’
= 120V (208Y/120V)
Rare
- or
Call
V = 120V (208Y/120V)
APT ‘2’to ground
Les
forAPTone
leg
one
piece
ofintoequipment.
is
bonded
‘7’Neutral
(non-USA)
=piece
127V
Call (non-USA)
V
= 127V
(220Y/127V)
APT
‘21’ (non-USA)
V = 120V
V
bonded
to‘4’
ground
via
grounding
resistor
Neutral
bonded
topulled
ground
Often
forNeutral
onebonded
leg may
or one
of (220Y/127V)
equip.
Neutral
may,
or may
not,
be pulled
into facility
Neutral
usually
pulled
facility
BV =
toor
ground
V = 347V (600Y/347V) APT ‘8’
V = 277V
(480Y/277V)
APT
‘5’
V = 277V Neutral
(480Y/277V)
APT
Neutral
pulled
into
facility
Neutral
NOT
facility
not
be
pulled into
facility
VV=into
(208Y/120V)
CallNeutral
= 120V
(120/240V)
APT
‘1’
V=
VV
=may
220V
=120V
220V
(380Y/220V) Rare
APT -‘7’
(non-USA)
(380Y/220V)
Call
(non-USA)
V
R
Becoming
popular
system
on into
high-tech
Very,
very pulled
Common
Less
common
than
perceived!
may,
or
may
not,
be
pulled
facility
Neutral
usually
into
facility
A
A
Neutral
bonded
to
ground
V = 127V (220Y/127V) APT ‘21’ (non-USA)
V
=
347V
(600Y/347V)
APT
‘9’
V = 347V Neutral
(600Y/347V)
APT
‘8’
AVless
V
= 277V (480Y/277V)
APT commonly
‘5’
V = 240V (240/480V)
Rare - CallN
V=
to
ground.
This
configuration
is
Common system configuration
Rare than
system configuration;
Error/miss-wire?
Common
system
configuration
atused
MCC,
V = 240V
(240/48OV)
Rare
Call
APT
V = 120V
Rare V
- Call
Vvery
= 120V
APT
‘1’
= 120V than
APTperceived!
‘11’V = 127V (127/254V)
popular
system
on high-tech
Very,
Common
V = 220V (380Y/220V) APT ‘7’ (non-USA)
=V127V (220Y/127V)
Call
(non-USA)
V = 127V Becoming
(220Y/127V)
APT (208Y/120V)
‘21’
(non-USA)
LessVcommon
B pumping
V
V =treatment
347V
(600Y/347V)
APT ‘9’
APT ‘15’ (non-USA)
V=
A
G(120/240V)
V
=
120V
(208Y/120V)
APT
‘2’
Note
NEC
285.3(2),
and
water
V
V
V
V = 220V (380Y/220V)
V = 220V V
(380Y/220V)
APT (480Y/277V)
‘7’ (non-USA)
V = 277V
V (non-USA)
=
240V
(240/480V)
V = 240V
= 120V
Rare
-APT
Call‘5’
V =Call
120V
(120/240V)
APT Rare
‘1’ - Call A R
V = 120V
APT APT
‘11’ ‘12’
perceived
(see
“split-phase”).
V=
N - Call
A APT
G(208Y/120V)
V = 127V (127/254V)
APT
‘15’
(non-USA)
V = V277V
(480Y/277V)
‘4’‘9’
V = 120V
(208Y/120V)
Rare
V=
120V
(208Y/120V)
APT
‘2’ (non-USA)
N
=
347V
(600Y/347V)
APT
V
=
127V
(127/254V)
APT
‘15’
V
=
277V
APT
‘16’
V = 277V (480Y/277V) APT ‘5’
V = 240V (240/480V) Rare - Call
V = 240V APT
‘12’
G
V=
V277V
V = 347V (600Y/347V) BAPT ‘8’
V
=
(480Y/277V)
APT
‘5’
V = 277V (480Y/277V) APT ‘4’
A
CB
V
V = 480V
V = 120V
‘11‘ APT ‘15’ (non-USA)
V = 347V
V = 127VAPT
(127/254V)
VV= 277V
APT APT
‘16’ ‘17’ Call – almost always different
V=
A (600Y/347V) APT ‘9’
R
A
V = 127V
(220Y/127V) APT ‘21’ (non-USA)
V = 347V
(600Y/347V)
APT G
‘9’
V = 347V (600Y/347V) APT ‘8’
Single-Phase
V
=
127V
APT
‘13’
(non-USA)
V = 480V APT ‘17’ Call – almost always different
Resistive or Impedance Grounded Wye V = 220V
Split-Phase
‘Single-Phase’
APT ‘7’ A (non-USA)V = 240V
V = 127V
VV
= 127V
APT are!
‘21’ G
(non-USA)
C V = 220V
Verify
where (220Y/127V)
Neutral
and Ground
C (380Y/220V)
APT (220Y/127V)
‘12’
(non-USA)Call
N (non-USA)
APT
‘12’
B
VC= 127V
APT
(non-USA)
V
G C Call
N V
BN
B ‘13’ (380Y/220V)
B
Bof equip.
Neutral bonded to ground via grounding resistor
Neutral bonded to ground
Often
for oneC
leg or one piece
V = 220V
V = 220V
(380Y/220V)
APT
‘7’ (non-USA)
(non-USA)
VImpedance
= 220V APT
‘12’ (non-USA)
A
G
R
Neutral may, or may not, be pulled into facility
Neutral
usually
pulled
into
facility
Resistive
or
Grounded
Wye
Split-Phase ‘Single-Phase’
Neutral
bonded
to
ground
N= 277V APT ‘16’
V
A
N
B
G Very, very
B
Neutral bonded toVground via grounding resistor
Becoming popular
system on high-tech
Less common than perceived!
A G A Neutral bondedVto ground
C Common
G
GV
Hi-Leg Grounded
Delta
V pulled into facility
AAPT
R V = 120V (208Y/120V)
B - almost
Neutral may,
be
Neutral usually pulled into facility
Aor may not,
A APT
BG
Rare - Call
V = 120V (120/240V)
APT ‘1’
V = 48OV
‘17’
always
different
V = 120V
APT
‘11’ Call
A
G
Single-Phase
Becoming popular system on Open
high-tech
Very, very Common
V NeutralAPT
= 277V
(480Y/277V)
‘5’ pulled into
VHi-Leg
= 240VGrounded
(240/480V)
Rare - Call
V
V
GV
Delta
Delta
A = 240V APT ‘12’
A
G
Neutral bondedVVto
ground.
often
V V = 120V
V
A (208Y/120V) Rare3-phase
Resistive
or Impedance
Grounded
Wye
Split-Phase
‘Single-Phase’
- Call 3 where
Vand
= 120V
(120/240V)
Verify
Ground
are! APT ‘1’
V 3-wire
= 127V
APTAPT
‘13’
3-phase
Delta
3-phase 3-wire
BCorner
= 347V (600Y/347V) APT ‘9’
VNeutral
= 127V
(127/254V)
‘15’C(non-USA)
bonded
to groundAPT
or 4-wireNeutralV
VUngrounded
= 277V
‘16’(non-USA)
G
V VDelta
G
V
= 277V
(480Y/277V) APTCould
‘5’
= 240V
Single-Phase
has no reference
to ground
Neutral oftenground
pulled into
facility
ungrounded,
Neutral bonded
via
grounding
resistor
Neutral
ground
Often
for one legcorner
or V
one
piece(240/480V)
of equip. Rare - Call
V = 480V
APTbonded
‘17’ Call to
–Grounded
almost
always
different
Csystem configuration.
VSystem
V
V be
facility. Common
BCommonto
Vreference
= 347V to(600Y/347V)
APTgrounded
‘9’ Verify
= 127V
(127/254V)
APT ‘15’ (non-U
Resistive
or into
Impedance
Grounded
WyeAPT
Split-Phase
‘Single-Phase’
L-L voltages
fixed
but
L-(non-USA)
system configuration
or Hi-leg
where NeutralVand
Ground
are!
V=
220V
APT
‘12’
Systeminto
has
ground
Vby=transformer,
127V
‘13’
(non-USA)
Single-Phase
Neutral may,
or
may
not,
be
pulled
facility
Neutral
usually
pulled
facility
Neutral
bonded
to
ground
C
A
N because
voltages
vary;
become
V = 120/240V APT
‘3’
Very rare,
tend
toone
be rural
Neutral
bonded
to G
ground
viacan
grounding
resistor
Neutral
bonded
to ground
Often
forN
leg or one piece of equip.
B phase
N is grounded
Resistive orAPT
Impedance
Split-Phase
‘Single-Phase’
Verify where
Neutral
and
Ground
are! toAPT
V =Known
220V
(non-USA)
V = 120/240V
‘3’ Grounded Wye
Cperceived!
B
B
Becoming
system
on may,
high-tech
Very,
very‘12’
Common
LessNeutral
common
unstable.
V popular
= 240/480V
Call’
Various
solutions,
Callthan
for
V =usually
240V APT
‘61’into facility
Neutral
orfor
may
not,
pulled
intooffacility
Neutral
pulled
bonded
toinfo
ground
Neutral bonded to ground via grounding resistor
Neutral bonded to ground
Often
one
leg be
or one
piece
equip.
R
C
A
V
=
240V
APT
‘6’
V = 120V
(208Y/120V)
-popular
Call bonded
= 120V (120/240V)
APT
‘1’
Vvery
= 480V
APT ‘51’
120V
APT than
‘11’ perceived!
Becoming
system
on
high-tech V 3-wire
Very,
Common
common
Neutral may, or
may APT
not, be pulled into facility
Neutral usually
pulled into
facility
to3-phase
ground
N Rare Neutral
V = 240/48OV
Call
Ungrounded
Delta C VV == Less
B APT
V = 480V
APT
‘5’
B
B - Call
B ‘91’
C
V = 600V
APT
(208Y/120V)
Rare
V = 120V
(120/240V)
APT ‘1’
Becoming popular system on high-tech
Very, veryVCommon
V240V
= 120V
APT‘12’
‘11’
Less
common
than
perceived!
= 277V (480Y/277V)V =APT
‘5’
V = 240V C(240/480V)
Rare
- Call
V120V
G
G G
V APT
= 600V
APT
C
A V(480Y/277V)
Note NEC
285.3(2) Rare - Call
AGAPT
V = 120V (208Y/120V) Rare - Call
V = 120V V(120/240V)
‘1’
‘11’
V =APT
277V
APT
‘5’‘9’ has
V = 240V
(240/480V)
V277V
= 240VAPT
APT‘16’
‘12’
Bfixed by
A285.3(2)
= 347V AAPT
(600Y/347V)
‘9’= 120V Note
V
=
127V
(127/254V)
‘15’
(non-USA)
V
=
System
NO
reference
to
ground.
L-L
voltages
N
NEC
Occasionally
seen
at
industrial
G
B
C
B‘12’
B
C
C
V = 277V (480Y/277V) APT ‘5’
V = 240V (240/480V) Rare - Call
= 240V APT
V = 347V V(600Y/347V)
APT ‘9’
V = 127V
(127/254V)
APT ‘15’ (non-USA)
V
=
277V
APT
‘16’
Hi-Leg
Grounded
Delta
A
V
G
system configuration at older
V = V480V
APT
‘17’ Call––almost
almost
always different
G
facilities, normally not used on new
V
V
V = 347V (600Y/347V) APT ‘9’
V = 127V
(127/254V)
APT C
‘15’G
(non-USA)
V =V277V Common
APT ‘16’G
= 480V
APT ‘17’ Call
always different
3-phaseV3-wire
Ungrounded
Delta
3-phase
3-wire Corner
transformer,
but
L-G
voltages
cantovary.
bonded
ground
facilities,
normally
not different
used
onNeutral
B construction
V = 480V industrial
APT ‘17’
Call – almost
always
V
= V127V
‘13’
(non-USA)
127V
APT
‘13’ (non-USA)
3/16/09
V APT
V
Single-Phase
SystemRev
hasDate:
no =
reference
to
ground
Neutral
Grounded Delta
Hi-Leg Grounded Delta V = 127V new
Open
Delta
APT
‘13’ (non-USA)
Goften pulled into facility
Gconstruction
V
=
220V
APT
‘12’
(non-USA)
V
=
220V
APT
‘12’
(non-USA)
Voltage
Diagrams
RevC
G
This
configuration
is
known
to
become
unstable.
L-L voltages
by
transformer,
butare!
LCommon
configuration
Resistive
orbonded
Impedance
Wye
Split-Phase
‘Single-Phase’
Verify
where fixed
Neutral
and Ground
System has reference to g
V = 220V 3-phase
APT ‘12’ (non-USA)
3-wire
Ungrounded
Delta system
3-phase
3-wire Corner
Neutral
to groundGrounded
3-phase
3 or 4-wire
3-phase 3-wire Corner Grounded Delta
G voltages
canleg
vary;
Known
to become
Vground
= 120/240V
APT ‘3’ Delta
because
B
phase
is groun
Neutral
bonded
to
ground
via
grounding
resistor
Neutral
bonded
to
Often
for
one
or
one
piece
of
equip.
System
has
no
reference
to
ground
Neutral
often
pulled
into
facility
Could
be
ungrounded,
corner
Grounded
Hi-Leg Grounded Delta
Open Delta
V = 240V
‘6’
B voltages
unstable.
V
= L240/480V
Call’ has reference toNeutral
V = 240V APT ‘61’
Neutral
may,
orsystem
may
not,
be pulled into
facility
Neutral
usually
pulled
into
facility
L-L
by APT
transformer,
but
Common
or Hi-leg
bonded
togrounded
ground
Bconfiguration
C B to ground because
A
System
3-phase
3-wire fixed
Ungrounded
Delta
3-phase
3-wire Corner ground
Neutral
bonded
to
ground
3 or 4-wire
System has reference
V = 240V
APT3-phase
‘6’ Very
A
AV = 480V APT ‘51’
N
A
A
G
voltages
can
vary;
Known
to
become
V
=
120/240V
APT
‘3’
rare,
tend
to
be
rural
B
Becoming
popular
system
on
high-tech
Very,
very
Common
A
C
Less
common
than
perceived!
B
because
B
phase
is
grounded
B
C
C
C
A
A
System hasVno=
reference
to
Neutral often pulled into facility
be ungrounded, corner VA= 600V APT ‘91’
Aground
48OV
APT
‘5’
Grounded Delta
= 480V APTCould
‘5’ Various
NVVA
unstable.
V = 240/480V
Call’ Rare - CallL-L voltages
Call for info
C
B
=has
240V
APT ‘61’
VVtransformer,
VCommon
= 120V
(208Y/120V)
= 120V
(120/240V)
APTV‘1’
= 120V APT
‘11’ B
V
B phase is grounded.
but Lsystem
grounded
or solutions,
Hi-leg
V
Vto ground
V
V fixed by
V
V configuration
System
reference
V = 600V APT
‘9’
Note NEC 285.3(2)
V = 240V
APT
‘6’= 240V
480VV APT ‘51’
VV== 277V
(480Y/277V)
APT ‘5’ V
V
(240/480V)
RareV -=Call
= 240V
APT
‘12’
V =vary;
600V
APT
‘9’
G voltages
can
Known
to become
120/240V
APT ‘3’
Very
rare, tendVto be rural
V480V
NEC 285.3(2)
because
B phase is groundedVNote
Occasionally seen at indus
G
G
V
=
APT
‘5’
V‘15’
= 600V
APT ‘91’
V = 240V APT ‘61‘
G
VV== 347V
(600Y/347V)
APT ‘9’
V = 127V (127/254V) VAPT
(non-USA)
VCommon
= 277V system
APT
‘16’
unstable.
240/480V
Call’
Various
solutions,
configuration
at Call
olderfor info facilities, normally
G
=
240V
APT
‘61’
G
not
used
V = 600V
APT
‘9’ 285.3(2)
G
Note NEC 285.3(2)
Note
NEC
Vindustrial
= 480V facilities,
APT ‘17’
Call – not
almost
different
normally
usedalways
on
V = 240V
construction
= 480V
APT ‘51’
OpenVDelta
Note APT
NEC ‘6’
285.3(2)
V = 48OV
APTHi-Leg
‘51’ Grounded Delta
Occasionally
seen at industrial
VDelta
= 127V
APT ‘13’ (non-USA)
new
construction
Hi-Leg
Grounded
V = 480V
APT
‘5’
3-phase 3-wire Ungrounded Delta
3-phase
3-wire
Corner
V
=
600V
APT
‘91’
Neutral bonded toAground
3-phase
3
or
4-wire
C
Common
system
configuration
at older
facilities,
normally
not
used
new APT3-phase
Common
systemCconfiguration
atNeutral
older
industrial
facilities.
C
A
3-wire Ungrounded Delta
3-phase 3bonded
to ground
V =on
220V
‘12’ (non-USA)
Bfacilities,
B
VC= 600V
APT
‘9’
System has C
no reference to ground
Could
be ungrounded,
corner
N Delta
NEC
285.3(2)
Grounded
V = 600V APTNeutral
‘91‘Noften pulled into facilityB
industrial
normallyBnot
used
on Note
B
CNeutral
construction
B into facility
C has no reference
C Grounded
System
often pulled
Rev Date: 3/16/09 to ground
Note has
NEC
285.3(2)
L-L voltages fixed by transformer, but LCommon system configuration
grounded
ornew
Hi-leg
Occasionally
seen
at industrial
System
to ground
newreference
construction
Normally,
this
is
not
used
on
construction.
C
A
L-L
voltages
fixed
by
transformer,
but
LCommon
system
configuration
System has
G voltages can vary; Known
become
V = 120/240V APT ‘3’
tend normally
to be ruralnot used on new
Common
system
configuration at older Very rare,
Note NEC 285.3(2)
Voltage Diagrams
RevC
because
B phase
is grounded
facilities,
G to B
N
G
to become
V = 120/240V
B Known
G = 240/480V Call’
C construction
because
Bp
B normally notGused onVarious
B info
CG voltages can vary;
C
G APT ‘3’
unstable.
V
solutions, Call for
facilities,
VG
=industrial
240V APT
‘61’
unstable.
V = 240/480VACall’
A
A
V = 240V A
Rev
Date:
3/16/09
Occasionally
seen atDelta
industrial facilities. V = 240V APT ‘6’
Hi-Leg Grounded
Open Delta
V =new
480V
APT
‘51’
construction
V = 240V APT ‘6’
Open
Delta
V = 480V A
Hi-Leg
Grounded
Open
Delta
3-phase 3-wire VUngrounded
3-phase 3-wire
Corner
Neutral bonded to ground
3-phase 3 or 4-wire
= 480V APTDelta
‘5’
V
Voltage
Diagrams
RevC
V = 600VVDelta
APT ‘91’
VV
= 480V APT ‘5’
V G
V = 600V A
System
has no reference
to ground
3-wire
3-phase 3-wire Corner
Neutral
oftenis
pulled
facilityon new
Could be ungrounded,
corner Ungrounded Delta
Normally,
this
notintoused
construction.
ground
3-phase 3 or 4-wire
Delta bonded
G
V = 600V
APT ‘9’
Note to
NEC
285.3(2)
GGroundedNeutral
V = 600V APT ‘9’
3-phase
33-phase
or 4-wire.
Note NEC 2
Common system configuration
V = 120/240V APT ‘3’
V = 240/480V Call’

L-L voltages fixed Note
by transformer,
but Lgrounded or
Hi-leg has no reference to ground
System has Neutral
reference
toOccasionally
ground
System
often
pulled into facility
Could be ungrounded, corner
Grounded Delta
NEC 285.3(2)
seen
at industrial
Note NEC 285.3(2)
Occasionally
G voltages can vary; Known to become
Very rare, tend
to be ruralfixed by transformer, but Lbecause
phase
is grounded
L-L
Common
system
configuration
groundedDelta
or Hi-leg
System has reference to ground
CommonHi-Leg
system configuration
atBolder
facilities,
normallyVarious
not used
onvoltages
new
Grounded
Open
Common system configuration
at older
unstable.
solutions,
Call for
V = 240V Delta
APT
‘61’
G
voltages
caninfo
vary; Known to become
V
=
120/240V
APT
‘3’
Very rare, tend to be rural facilities, nor
because B phase is grounded
facilities,bonded
normallyto
notground
used on
construction
industrial facilities,3-phase
normally not
used
on
construction
V = 240V APT ‘6’industrialNeutral
3-phase
3-wire
Ungrounded
Delta
3-phase
3-wire
Corner
3
or
4-wire
V = 480V
APT
‘51’
unstable.
V = 240/480V Call’
Various solutions, Call for info
Rev Date: 3/16/09
V = 240V APT ‘61’
new construction
V = 480V APT ‘5’new construction
V = 600Vinto
APT
‘91’
System has no reference
to ground
Neutral
facility
Could be ungrounded, corner
Grounded
Delta
V = 240V APT
‘6’Voltage Diagrams
C often pulled
A
APT ‘51’
RevCV = 480V
V = 600V APT ‘9’
Note NEC
N 285.3(2)
V =by
480V
APT
fixed
transformer,
Common system
configuration
grounded orCHi-leg
= 600V
APT
C ‘5’ but LB
B System Vhas
C ‘91’
reference
to ground B
Note NEC 285.3(2)
Occasionally
seen at industrial L-L voltages
V = 600V
APT to
‘9’ become
NEC 285.3(2)
Common system configuration
older
G voltages can vary;
Known
V =at120/240V
APT ‘3’
Very rare, tend to be rural
facilities,
normally not used on new
becauseNote
B phase
is grounded
Note NEC 285.3(2)
Occasionally seen at industrial
industrial facilities, normallyV
not=used
on
construction
unstable.Rev Date:Common
240/480V
Call’
Various solutions, Call for info
V = 240V
APT ‘61’
3/16/09 system configuration
new construction
facilities, normally not used on new
G at older
G

Could be ungrounded, corner grounded or Hi-leg.
Very rare, tend to be rural. Various solutions.
Call APT for information.

G

Hi-Leg Grounded Delta
Neutral bonded to ground
Neutral often pulled into facility
Common system configuration
V = 120/240V APT ‘3’
V = 240/480V Call’

“Protecting the electronic world from surges”
52

V = 240V
APTDiagrams
‘6’
Voltage
APT ‘51’
industrial RevC
facilities, normally not usedVon= 480V
th construction
Rev Date: 3/16/09
V = 480V APT ‘5’
new construction
V = 600V APT ‘91’
Open Delta
Voltage Diagrams RevC
V = 600V
APTUngrounded
‘9’
Note
NEC Corner
285.3(2)
3-phase
3-wire
Delta
3-phase
3-wire
3-phase 3 or 4-wire
Note has
NEC
Occasionally
System
no285.3(2)
reference to ground
Grounded
Delta seen at industrial Could be ungrounded, corner
system
configuration
L-LCommon
voltages fixed
by transformer,
butatL-older Systemfacilities,
normally
not used on new
grounded or Hi-leg
has reference
to ground
industrialcan
facilities,
normally
not used onbecause
G voltages
vary; Known
to become
Very rare, tend to be rural
construction
B phase is grounded
Rev Date:
3/16/09
unstable.
Various solutions,
Call for
info
new construction
V = 240V APT ‘61’

14550 58 Street North, Clearwater, Florida 33760
(727) 535-6339 • (800) 237-4567 • Fax (727) 539-8955
www.aptsurge.com • info@aptsurge.com

V = 240V APT ‘6’
V = 480V APT ‘5’
V = 600V APT ‘9’
Note NEC 285.3(2)

V = 480V APT ‘51’
V = 600V APT ‘91’
Note NEC 285.3(2)
Occasionally seen at industrial

Voltage Diagrams RevC

Frequently Asked Questions
WHAT IS AN SPD?

SPD is an abbreviation for “Surge Protective Device.”
An SPD is a device that attenuates (reduces in magnitude)
random, high energy, short duration electrical power
anomalies caused by utilities, atmospheric phenomena
or inductive loads.
Such anomalies occur in the form of voltage and current spikes
with a duration of less than half an AC cycle. These high energy
power spikes can damage sensitive electronic equipment, such
as computers, instrumentation and process controllers.

WHERE ARE SURGE SUPPRESSORS INSTALLED?

AC surge suppressors are typically installed in the following areas:
1. a utility service entrance for protection of an entire facility.
2. in distribution panelboards and switchboards for protection
of sensitive downstream loads.
3. connected to a wall outlet for individual protection of a
specific piece of equipment, such as a computer or solid-state
controller

WHAT FEATURES SHOULD BE CONSIDERED WHEN
SELECTING A SURGE SUPPRESSOR?

Two important areas to consider during the selection of a surge
suppressor are performance and safety. The performance of
a surge suppressor is measured in surge current capacity and
clamping voltage. Safety should also be a priority in this selection
process. The individual suppression circuit should be fused to
clear an inoperative MOV during an extreme transient event
and provide overcurrent protection for the surge suppressor
during a fault condition.

SPACE IS A CONCERN, DOES APT OFFER SOLUTIONS
FOR DIN-RAIL APPLICATIONS?

WHAT SURGE CURRENT CAPACITY IS REQUIRED?

Surge current capacity is dependent on the application and the
amount of required protection. The selection of the proper surge
suppressor is not an exact science and cannot be scientifically
calculated from a standard algorithm.
Questions to consider when specifying the proper surge current
capacity for surge a surge suppressor include:
• What is the geographic location of the facility and its
susceptibility to lightning? (For example, Florida is a highlightning area; California is a low-lightning area.)
• Is the facility in a rural or urban setting?
• Is the facility the tallest building around?
• Is the facility at the end of the utility grid?
• If it is an existing facility, what is its power quality history?

DOES APT OFFER SPD PRODUCTS FOR RENEWABLE
ENERGY APPLICATIONS?

Yes. APT offers a variety of solutions that can accommodate
both the needs of the wind and solar markets.

WHAT ARE YOUR STANDARD LEAD-TIMES?

Our normal ship date is no more than 10 days from the receipt
of the purchase order on custom builds and same day shipping
for the most common modular and non-modular inventory units
ordered before 2:00 pm EST.

WHY WOULD I BUY FROM APT?

As a leading manufacturer of quality U.S. made products, our
highly trained design engineers have designed SPD products
that are of high quality, low in cost and contain the highest
level of performance and safety features! You are working
directly with the manufacturer. Who knows our product better
than we do?

Yes. APT offers a wide range of DIN-Rail SPD solutions. Our
AC products range from 120V to 600V. In addition, we have
a series of DC and low voltage DIN-Rail surge suppressors. Our
SPDee product is also DIN-Rail mountable.

I AM A SYSTEMS INTEGRATOR AND BUILD CUSTOM
FABRICATIONS. WHAT DOES APT OFFER THAT
WOULD PROTECT MY SOLUTIONS?

We have a hard wired SPD solution for every type of panelboard,
switchgear, motorcontrol and PLC application. Within our line of
products we offer external, internal, modular and non-modular
configurations. We also custom design.

53

1

Panel

Surge Protectors

MAIN ZONE

The FIRST LINE of defense is the key
to protecting your home. Panel Surge
Protectors are installed at the main
power panel, cable TV/satellite service
and telephone service.

2

S50A

SA Series

Cable/Phone
Surge Protectors

The SECOND LINE of defense
designed to protect coaxial cable lines
and phone lines.

SAVFFF

SATH2

3

SATHW2

Interior

INTERIOR
ZONE

Surge Protectors
The THIRD LINE of defense is
for sensitive electronics inside
the home.

SAP1

SP-6TVN

4

PS-6DL

Exterior

EXTERIOR
ZONE

Surge Protectors
The FOURTH LINE of defense is for
equipment located outside the home
such as the HVAC, pool equipment
and generators.

S50A

SPDEE

SURGE PROTECTIVE DEVICES
surgeassure™ is the residential division of Advanced

Protection Technologies and ASCO Power Technologies. We
are the preferred vendor for Mr. Electric and have won the Mr.
Electric vendor of the year award in 2008, 2009 and 2011.

We have been in the surge protection industry since 1985. Our primary
goal is to save you time and money when dealing with SPDs. We have
an “equal” to any competitive product, and have on staff engineers that
can be reached during business hours when you are in the field and have
technical/installation questions.
In addition to our quality products that are UL-1449 listed we provide
Factory-direct pricing, unparalleled customer service, FREE product and
sales training, and FREE customized marketing support. We also offer
customized brand labeling agreements.
surgeassure™ is a strong, financially stable company who is a proven
industry leader! We are the manufacturer, which allows you factory direct
pricing and quick ship out dates surgeassure™ has an experienced and
trained customer service team who are ready and available to assist your
needs. You will ALWAYS get a live representative when you call.
We at surgeassure™, not only have the best product but we also show we
care about our customers. When it comes to a surgeassure™ product, our
mission is to keep your customers home and electronic equipment safe
from surges.

SPDEE DC

Surge protectors are designed to reduce potentially damaging short duration voltage spikes safely out of the system and divert
them to ground. Homeowners these days are becoming more educated about surge protection and are realizing how important it is
to install protection in and outside of their homes. This means residential is now a huge potential market. We at surgeassure™ can
give you all the tools needed to have a successful surge protection program!

surgeassure™ is the Preferred Vendor of: MR. ELECTRIC AND SERVICE ROUNDTABLE
surgeassure™ Brand Labels: MR. ELECTRIC, HITACHI AND SIEMENS
54

1.800.727.0669 | surgeassure@ascopower.com | www.surgeassure.com

FOR TECHNICAL OR APPLICATION
QUESTIONS, CONTACT:

800.237.4567

14550 58th Street North, Clearwater, FL 33760
info@aptsurge.com

www.aptsurge.com
10.27.17.RevL



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Has XFA                         : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Instance ID                     : uuid:75e12d8f-d394-4d1e-9bfa-e86b6eb461c9
Original Document ID            : adobe:docid:indd:36fb56da-8201-11de-97e4-fac8ef4948fb
Document ID                     : xmp.id:ad835f63-dccb-064e-a314-0101364186cc
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:bed7b58a-ab97-f441-89fc-e383ed4caab8
Derived From Document ID        : xmp.did:34251c89-3fe1-d742-b3c2-d939d85e274b
Derived From Original Document ID: adobe:docid:indd:36fb56da-8201-11de-97e4-fac8ef4948fb
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.0 (Windows)
History Changed                 : /
History When                    : 2017:10:27 09:54-04:00
Create Date                     : 2017:10:27 09:54-04:00
Modify Date                     : 2017:10:27 09:56:18-04:00
Metadata Date                   : 2017:10:27 09:56:18-04:00
Creator Tool                    : Adobe InDesign CC 13.0 (Windows)
Format                          : application/pdf
Title                           : APT_Product_Catalog_revL.indb
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 56
Creator                         : Adobe InDesign CC 13.0 (Windows)
EXIF Metadata provided by EXIF.tools