1109

LEM-1DL Supplemental Instructions
Single Master Station with Door Release
- REFER TO INSTALLATION MANUAL INSIDE LEM-1DL BOX FOR STANDARD
INSTALLATION INFORMATION The LEM-1DL master station provides communication to and from a door station, and has a separate button
for door release. This supplemental instruction manual addresses many of the additional functions and
modifications for the LEM-1DL system, including installation and troubleshooting information.
MASTER STATION:
LEM-1DL:

1-call master station with “Normally Open” door release button

DOOR STATIONS: (Note: Door stations are weather resistant, made for outdoor use)
LE-D:		
LE-DA:		
LS-NVP/C:
LE-SS:		
LE-SSR:		
		
LE-SS-1G:

Surface mount, plastic door station (included with LEM-1DLS Set)
Flush mount in 2-gang box, stainless steel cover
Vandal resistant flush mount in 3-gang box, white powder-coat finish
Vandal resistant flush mount sub in 2-gang box, stainless steel
Vandal resistant, red mushroom button, flush mount in 2-gang box, 		
stainless steel
Vandal resistant flush mount sub in 1-gang box, stainless steel

LEM-1DL

OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A:
DAK-2S:		
		
SBX-NVP:
SBX-2G:		
SBX-1G-SS:
EL-12S:		
PT-1210N:
PS-1225UL:
822202:		
		
		
		

External signaling relay (Requires 12VDC power supply)
Dual master adaptor kit
(1 per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
Surface mount box for LS-NVP/C
Surface mount box for LE-SS, LE-SSR, LE-DA
Surface mount box for LE-SS-1G
Door strike (for interior wood frame doors only)
AC 12V Transformer (used for door strike and for each master station)
12V DC Power Supply, 2.5A, UL Listed
2 conductor, 22AWG, Shielded wire
(Available in 500’ and 1000’ boxes)
Install two separate runs of this cable, one for the intercom and one for 		
the door release.

LE-D

LE-DA

LS-VNP/C

LE-SS

DAK-2S

(2 component modules per kit)

DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.

LEM-1DL

LEM-1DLS Set contains:
1 LEM-1DL, 1 LE-D, 1 PT-1210N.
Door strike not included.

LE-D

2 cond. shielded for intercom

Separate 2 conductor for door release

!

PT-1210N
Power
Source
for Strike

If using a non-Aiphone door strike, use separate power
source for door release mechanism.

LEM-1DL Supplement
Pg. 1

WIRING DIAGRAM: Dual Master LEM-1DL System with DAK-2S Dual Master Adaptor
LE-D

1

Component
Module

E
-

Please read and understand all
instructions before installation.

LEM-1DL

1

Component
Module

LEM-1DL

1
E

E

Leave
E/- jumper
attached

PT-1210N

PT-1210N

+

!

If using a non-Aiphone door strike,
use a separate power source for the
door release mechanism.

Aiphone EL-12S

-

+
-

EL
EL

EL
EL

IMPORTANT!!!
Each master REQUIRES an individual power supply.

OPERATION NOTES:

1. Only one master can be used at a time.
2. If both masters are activated, a feedback (squeal) will be heard through the system when either TALK button is pressed.
3. If feedback occurs, press the OFF button on one of the LEM-1DL masters.

INSTALLATION GUIDELINES:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Use 2 conductor shielded wire from the door station to the first master, then to the second master.
Install the units at the desired locations.
Separate PT-1210N power supplies are required for each master station. NOTE: Connect power leads to master BEFORE plugging in power supply
Install the bare wire leg of the component module directly onto the “1” terminal of the LEM-1DL’s.
Attach the wire coming form the “1” terminal of the LE-D to the colored wire end of the component modules at both masters. (The component
		
modules will easily fit within the space available.)
Connect the “E” terminals between the door station and master stations.
If door release is included, use a separate 2-conductor wire from the “EL” terminals of the masters through an AC transformer and to the door strike.
The EL-12S is designed for a standard wood framed door, and for light and medium usage. If a different type of door is used, install a strike 		
appropriate for the door.
The door release button on the master station is a “Normally Open” contact closure. Contact rating is 30V AC/DC @ 1 Amp.

4 LEM-1DL Master Stations with 1 Door
LE-D

LEM-1DL

1

1
Component
Module

E
-

Component
Module

Door Strike

Power Source
for door strike

LEM-1DL Supplement
Pg. 2

1

Component
Module

1

Component
Module

E

E
PT-1210N

LEM-1DL

LEM-1DL

LEM-1DL

E
PT-1210N

Note: In a multi-master system, all masters only talk to the
door station, and only one master can be on at a time

1

E
PT-1210N

PT-1210N

+
-

+
-

+
-

+
-

EL
EL

EL
EL

EL
EL

EL
EL

WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC Relay
LE-D

Component
Module

1
E
-

LEM-1DL

NOTE: Intercom must be
powered with a 12VDC
power suplly when RY-AC
is connected.

Leave
E/- jumper
attached

Normally Open Dry
Contact to door
strike and power

1

Output of RY-AC (Yellow
wires) provide a momentary
dry contact closure while
the call button on the door
station is being pressed.

E

+
EL
EL

PS-1225UL

White

+
-

Red
Black

BELL

RY-AC
Power source
for bell

Component Module
If a DAK-2S is not available, install components as shown below.
Capacitor: 25V, 15-33ufd Non-polarized
Diode: 1N4148

To 1 of LE-D and
WHITE wire of RY-AC

To 1 of LEM-1DL

SYSTEM CONFIGURATION:
LEM-1DL with Door Release contact activating a Normally Closed relay for a Magentic Lock
Note: For applications requiring a Normally Closed (N/C) contact (Magnetic locks, etc.), an external
relay should be chosen based on the lock’s power source.
- When using a 12-18V DC magnetic lock, Aiphone’s RY-18L relay may be used.
- For 24V DC magnetic locks, Aiphone’s RY-24L relay may be used.
- A 3rd party relay of similar specifications may also be used. Refer to manufacturer’s 			
documentation for connection details.
LE Series Sub

LEM-1DL

1

1

E
-

E

Leave
E/- jumper
attached

LOCK
POWER

+
-

+
-

EL
EL
RY-18L / RY-24L

MAGNETIC LOCK WIRING METHOD:
Magnetic Lock

COM
N/C

Red
Blk
Brn
Org

(Normally Closed Contact)
Lock Power: Power source for Magnetic Lock
When using 12-18V DC, use the RY-18L
When using 24-36V DC, use the RY-24L

Yel

Use Brown & Yellow wires
when connecting to a Maglock.

LEM-1DL Supplement
Pg. 3

INSTALLATION TIPS:
1. Use shielded wire for the communication path, and ground one end of the shield to an earth ground.
2. Run intercom wire at least 20” away from AC wiring, fluorescent lights or dimmer switches.
3. Keep intercom cable away from alarm, data, phone, and video cables.
4. Door release wires must be in a separately jacketed cable from the intercom wires. Use two separate
cables; one for audio and one for door release.
5. When installing a second master station, wire must be run from the first master station, not from the 		
door station. See diagram on page 2.
6. Do not install master station near light switches, dimmer switches, or other devices that may cause 		
interference with the intercom system.
7. Do not install the master station on the opposite wall from the door station. If the units are too close, 		
acoustical feedback may result.

TROUBLESHOOTING GUIDE:
PROBLEM

POSSIBLE CAUSE

No call tone from door to master station.

(A) Press OFF button on master. If call tone still doesn’t come
through, read solution (B).
(B) Make sure jumper is attached to E/- terminals on door
(A) OFF button on master not pressed. station (or proper wires jumpered on LS-NVP, LE-SS subs).
(B) E/- jumper not attached.
Wire from E/- should be connected to E of master.

No communication from door station.

E/- jumper not attached

Ensure that the jumper at the door station is attached between
E and - terminals

No call tone, no communication. Chirping
sound when volume control is turned all the
way up.

Wrong voltage on LEM-1DL

Check power supply. If it’s a model SKK-620, remove and
replace with model PT-1210N. Verify that voltage on +/terminals is between 12-16V AC or 12-24V DC.

In a system with RY-AC and external signaling
device connected, the external device is
activated every time TALK button is pressed.

Make sure the component module is installed with the bare
DAK-2S component module missing or wire under the 1 terminal and the white wire of the RY-AC
installed incorrectly.
spliced to the colored wire.

In a dual master system, call tone is heard
at the second master when pushing the talk
button on one master.

Missing DAK-2S dual master adaptor
kit.

Install 1 component module from the DAK-2S at each master.
See Pg. 2. If DAK-2S is not available, connect specified diode
and capacitor in parallel and install as shown on PG. 3.

In a dual master system, feedback occurs
when pressing the talk button.

One power supply is used for both
masters.

Ensure that each master has its own power supply. Use any
power supply with output between 12-16V AC or 12-24V DC.
Aiphone recommends the PT-1210N.

AC noise when listening to the door station

Intercom wiring run close to AC wiring.

Ensure that the intercom wire is run at least 20” from any AC
electircal wire, or crossed at 90 degrees. Intercom wire should
be shielded, with the drain wire connected to an earth ground
at the master end.

AC noise when talking to the door station

Power wires run with communication
wires.

Ensure that power wires coming from the PT-1210N are not
run in the same jacket cable with the communication wires run
to the door.

Aiphone Communcation Systems
1700 130th AVE N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

SOLUTION

Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com

LEM-1DL Supplement
Pg. 4
#90111
1109JD



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:42
Instance ID                     : uuid:d9419777-26b4-4d62-8f83-a0dbcadb703e
Document ID                     : adobe:docid:indd:aacd6357-fba6-11de-9972-93d40c9f038d
Rendition Class                 : proof:pdf
Derived From Instance ID        : 4a4605bc-dde6-11de-81c2-913a5eec6183
Derived From Document ID        : adobe:docid:indd:4a4605bb-dde6-11de-81c2-913a5eec6183
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:BEE2A3B1E1D2DE118A6AE2BADDACE995, uuid:BCE2A3B1E1D2DE118A6AE2BADDACE995, uuid:BAE2A3B1E1D2DE118A6AE2BADDACE995, uuid:C0E2A3B1E1D2DE118A6AE2BADDACE995, uuid:BE4695EA0156DE11BF5FEF9B9A087105, uuid:3E993323BD4FDE1191B4C33F426A664C, uuid:2E4DD4FA6545DE1191E9DC4A8DC14CEE, uuid:6846C9FD0C56DE11BF5FEF9B9A087105, uuid:BB84D6DA6545DE1191E9DC4A8DC14CEE, uuid:8239417B7C50DE119DBFE44D213C87E7, uuid:BAE2A3B1E1D2DE118A6AE2BADDACE995, uuid:BAE2A3B1E1D2DE118A6AE2BADDACE995, uuid:FC2D1181E6D2DE118A6AE2BADDACE995
Manifest Reference Document ID  : uuid:BDE2A3B1E1D2DE118A6AE2BADDACE995, uuid:BBE2A3B1E1D2DE118A6AE2BADDACE995, uuid:B9E2A3B1E1D2DE118A6AE2BADDACE995, uuid:BFE2A3B1E1D2DE118A6AE2BADDACE995, adobe:docid:photoshop:5f07f9e2-57be-11da-9393-f77522347299, uuid:3D993323BD4FDE1191B4C33F426A664C, uuid:2D4DD4FA6545DE1191E9DC4A8DC14CEE, uuid:6746C9FD0C56DE11BF5FEF9B9A087105, uuid:BA84D6DA6545DE1191E9DC4A8DC14CEE, uuid:4604E078A446DC119A4CE12AD2A5A028, uuid:B9E2A3B1E1D2DE118A6AE2BADDACE995, uuid:B9E2A3B1E1D2DE118A6AE2BADDACE995, uuid:8A6377CEE2D2DE118A6AE2BADDACE995
Create Date                     : 2010:01:07 08:07:24-08:00
Modify Date                     : 2010:01:07 08:07:33-08:00
Metadata Date                   : 2010:01:07 08:07:33-08:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 11468 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu