000.005 Install Man B&W Armaflex Sheet Installation
User Manual: Armaflex Sheet Installation
Open the PDF directly: View PDF .
Page Count: 9
Download | ![]() |
Open PDF In Browser | View PDF |
Please note: For installing self adhering SA Armaflex sheets and rolls, refer to p.19. Installation: 4.b. Using Armaflex sheet insulation on pipes Application to pipes 1. Apply Armaflex Sheet Insulation on pipes larger than 5″ IPS. Cut the sheet insulation to proper width, permitting it to fit loosely without stretching around the pipe. (See pgs 11-12.) The fabrication must be done at the job site, at the same ambient conditions as the application. 2. Brush-coat both surfaces of the lengthwise seam with 520 or 520 BLV Adhesive. Allow the adhesive to dry until tacky to the touch under slight pressure before joining surfaces. Wrap the sheet around the pipe, and seal the seam by pressing the surfaces firmly together. Join butt joints between individual sections using 520 or 520 BLV Adhesive. On horizontal pipes larger than 12″ IPS, adhere insulation on lower one-third. ting cover, the complete fitting cover is formed by adhering two halves together at the long outer arc. Coat both surfaces with 520 or 520 BLV Adhesive. Allow the adhesive to dry until dry to the touch but tacky under slight pressure before joining surfaces. Then seal the seam by pressing the surfaces firmly together throughout. To do this, press the adhesive joint on the rough side and then snap the cover inside out and press the joint on the smooth skin side. (The tee template is a symmetrical half, but, in this case, both halves are laid out together to form the complete outline of the fitting cover.) 1 3 2 4 Application to fittings 3. Fitting covers are easily made, using templates designed specially for screwed fittings 2″, 21/2″ and 3″ and long-radius weld fittings from 3″ to 10″ IPS. (See size chart, pg 11.) Note: Templates should be traced on stiff paper, sheet metal or hardboard and cut out to make reusable patterns. 4. Since each template for 45˚ and 90˚ ells is shown as a symmetrical half of the full fit- 9 Please note: For installing self adhering SA Armaflex sheets and rolls, refer to p.19. Installation: 5. Snap the formed cover in place over the fitting. Adhere the mating surfaces of the inner arc joint with 520 or 520 BLV Adhesive. Join the straight pipe covering to the fitting cover, making sure to coat both the pipe-section butt surface and the fitting-cover butt surface. Note: On screwed fittings, select the proper template from section 4.b.1., page 11. Notice that the screwed fitting cover templates allow for the 1″ minimum overlap on the straight pipe next to the fitting. Remember to cement this 1″ overlap with 520 or 520 BLV Adhesive by forcing the brush between the two surfaces. 6 5 TEMPLATE FOR VICTAULIC COUPLING 45° ELL 6. Allow the adhesive to dry until dry to the touch but tacky under slight pressure before joining surfaces. Press surfaces firmly together to seal. ▲ ARMAFLEX DONUTS ▲ Application to Victaulic Couplings Make two donuts, and place on both sides of the Victaulic Coupling. Complete the fitting cover by gluing the circumferential strip of sheet insulation over the two donuts. 90° ELL CIRCUMFERENCE ▲ TEE 10 Installation: 4.b.1 Templates are available for screwed and long-radius weld fittings Template number and description Templates for the Iron Pipe Sizes Shown Below in 3/8″, 1/2″ and 3/4″ Armaflex: No. AT Set A Screwed 45˚ Elbows ■ 3/8″—1/2″—3/4″ Walls ■ 2″, 2-1/2″, 3″ IPS SCREWED Pipe Size IPS 2" 2-1/2″ 3" 3/8″ 1/2″ 3/4″ No. AT Set B Screwed 90˚ Elbows ■ 3/8″—1/2″—3/4″ Walls ■ 2″, 2-1/2″, 3″ IPS 45˚ 90˚ T 45˚ 90˚ T 45˚ 90˚ T • • • • • • • • • • • • • • • • • • • • • No. AT Set C Screwed Tees ■ 3/8″—1/2″—3/4″ Walls ■ 2″, 2-1/2″, 3″ IPS WELD Pipe Size IPS 3/8″ 1/2″ 3/4″ 1″ ... AP ARMAFLEX SHEET AS PIPE INSULATION Insula- Insulation tion Width ″ Pipe Thick(Pipe Size ness Circum.) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1/2″ • • • • • • • • • • • • • • 3/4″ • • • • • • • • • • • • • • • • • • • • • • • • • • • • No. AT Set E Weld 45˚ Long-Radius Elbows ■ 3/4″ Wall ■ 3″ IPS thru 10″ IPS No. AT Set F Weld 90˚ Long-Radius Elbows ■ 1/2″ Wall ■ 3″ IPS thru 10″ IPS No. AT Set G Weld 90˚ Long-Radius Elbows ■ 3/4″ Wall ■ 3″ IPS thru 10″ IPS VICTAULIC COUPLINGS 3/8″ • • • • • • • • • • • • • 1″ • • • • • • • • There are twelve template sheets—order from Armacell. Templates for Victaulic Couplings and standard grooved end fittings are also available. No. AT Set H Weld Tees ■ 1/2″ Wall ■ 3″ IPS thru 10″ IPS No. AT Set I Weld Tees ■ 3/4″ Wall ■ 3″ IPS thru 10″ IPS No. AT Set J Weld Tees ■ 1″ Wall ■ 3″ IPS thru 10″ IPS Sheet LF DropLength Sheet Off 3″ IPS 1/2 3/4 1 13-1/2 14-5/8 15-5/8 36 36 36 9 9 9 7-1/2 4-1/8 1-1/8 3-1/2″ IPS 1/2 3/4 1 15-1/8 16-1/8 17-1/8 36 48 48 9 8 8 2-5/8 3-3/4 1-3/4 4″ IPS 1/2 3/4 1 16-5/8 17-3/4 18-3/4 48 48 36 8 8 6 2-3/4 1/2 10-1/2 5″ IPS 1/2 3/4 1 1-1/2 20 21-1/8 22-1/8 25-3/8 36 36 36 48 6 6 6 4 8 5-3/4 3-3/4 10-5/8 6″ IPS 1/2 3/4 1 1-1/2 23-3/8 24-1/2 25-3/8 28-1/2 36 48 48 48 6 4 4 4 1-1/4 11-1/2 10-5/8 7-1/2 8″ IPS 1/2 3/4 1 1-1/2 29-5/8 30-3/4 31-3/4 34-7/8 48 48 48 48 4 4 4 4 6-3/8 5-1/4 4-1/4 1-1/8 10″ IPS 1/2 3/4 1 1-1/2 36-1/4 37-3/8 38-3/8 41-1/2 36 36 36 36 3 3 3 3 11-3/4 10-5/8 9-5/8 6-1/2 12″ IPS 1/2 3/4 1 42-5/8 43-5/8 44-5/8 36 36 36 3 3 3 5-3/8 4-3/8 3-3/8 14″ IPS 1/2 3/4 46-1/2 47-5/8 36 36 3 3 1-1/2 3/8 45˚ 90˚ T 45˚ 90˚ T 45˚ 90˚ T 45˚ 90˚ T 3″ 3-1/2″ 4″ 5″ 6″ 8″ 10″ Pipe Size 3/4″ 1″ 1-1/4″ 1-1/2″ 2″ 2-1/2″ 3″ 3-1/2″ 4″ 5″ 6″ 8″ 10″ 12″ No. AT Set D Weld 45˚ Long-Radius Elbows ■ 1/2″ Wall ■ 3″ IPS thru 10″ IPS 4.b.2. yields of ... For jobsite application sizing. Not intended for shop prefabrication. Yield of Armaflex Sheet (36″ x 48″) when used on various pipe sizes. All dimensions are in inches. No. AT Set K Weld 45˚ Long-Radius Elbows ■ 1″ Wall ■ 3″ IPS thru 10″ IPS No. AT Set L Weld 90˚ Long-Radius Elbows ■ 1″ Wall ■ 3″ IPS thru 10″ IPS 11 Installation: LF/R OLL (Ft. ) PCS (4-F ./ROL t. Le L ngth s) ... AP ARMAFLEX SHEET FOR WELDED 90˚ ELBOW FITTINGS INS U LEN LATIO (Pip GTH N eC ircu m., In.) APP R LEN OX. GTH ROL (LF L ) ... 48-INCH-WIDE AP ARMAFLEX ROLLS AS PIPE INSULATION INS U THI LATIO C (In.) KNES N S 4.c. measuring ... PIP E SIZ E Yields of ... Half Circumference Plus Throat Meas. R1 Pipe Size OD ″ Pipe OD ″ Sheet Thickness R2 Short Radius Long Radius Short Radius Long Radius 3″ IPS 1/2 3/4 1 13-1/2 14-5/8 15-5/8 70 50 35 62 41 26 248 164 104 3 3 3 3-1/2 3-1/2 3-1/2 1/2 3/4 1 1-1/4 1-1/4 1-1/4 2-3/4 2-3/4 2-3/4 8 8-1/2 9 9-1/2 10 10-1/2 3-1/2″ IPS 1/2 3/4 1 15-1/8 16-1/8 17-1/8 70 50 35 55 37 24 220 148 96 3-1/2 3-1/2 3-1/2 4 4 4 1/2 3/4 1 1-1/2 1-1/2 1-1/2 3-1/4 3-1/4 3-1/4 9 9-1/2 10 10-3/4 11-1/4 11-3/4 4″ IPS 1/2 3/4 1 16-5/8 17-3/4 18-3/4 70 50 35 50 33 22 200 132 88 4 4 4 4-1/2 4-1/2 4-1/2 1/2 3/4 1 1-3/4 1-3/4 1-3/4 3-3/4 3-3/4 3-3/4 10-1/8 10-5/8 11-1/8 12-1/8 12-5/8 13-1/8 5″ IPS 1/2 3/4 1 1-1/2 20 21-1/8 22-1/8 25-3/8 70 50 35 25 42 28 18 11 168 112 72 44 5 5 5 5-9/16 5-9/16 5-9/16 1/2 3/4 1 2-1/4 2-1/4 2-1/4 4-3/4 4-3/4 4-3/4 12-1/4 12-3/4 13-1/4 14-3/4 15-1/4 15-3/4 6″ IPS 1/2 3/4 1 1-1/2 23-3/8 24-1/2 25-3/8 28-1/2 70 50 35 25 35 24 16 10 140 96 64 40 6 6 6 6-5/8 6-5/8 6-5/8 1/2 3/4 1 2-3/4 2-3/4 2-3/4 5-5/8 5-5/8 5-5/8 14-1/2 15 15-1/2 17-1/4 17-3/4 18-1/4 1/2 3/4 1 1-1/2 29-5/8 30-3/4 31-3/4 34-7/8 70 50 35 25 28 19 13 8 112 76 52 32 8 8 8 8-5/8 8-5/8 8-5/8 1/2 3/4 1 3-3/4 3-3/4 3-3/4 7-5/8 7-5/8 7-5/8 18-1/2 19 19-1/2 22-3/8 23 23-3/8 10 10 10 10-3/4 10-3/4 10-3/4 1/2 3/4 1 4-5/8 4-5/8 4-5/8 9-5/8 9-5/8 9-5/8 22-3/4 23-1/4 23-3/4 27-3/4 28-1/4 28-3/4 10″ IPS 1/2 3/4 1 1-1/2 36-1/4 37-3/8 38-3/8 41-1/2 70 50 35 25 23 16 10 7 92 64 40 28 12 12 12 12-3/4 12-3/4 12-3/4 1/2 3/4 1 5-5/8 5-5/8 5-5/8 11-5/8 11-5/8 11-5/8 26-7/8 27-3/8 27-7/8 32-7/8 33-3/8 33-7/8 12″ IPS 1/2 3/4 1 1-1/2 42-5/8 43-5/8 44-5/8 47-3/4 70 50 35 25 19 13 9 6 76 52 36 24 14 14 14 14 14 14 1/2 3/4 1 7 7 7 14 14 14 30-1/4 30-3/4 31-1/4 37-1/4 37-3/4 38-1/4 14″ IPS 1/2 3/4 1 1-1/2 46-1/2 47-5/8 48-1/2 51-3/4 70 50 35 25 18 12 8 5 72 48 32 20 16 16 16 16 16 16 1/2 3/4 1 8 8 8 16 16 16 34-3/8 34-7/8 35-3/8 42-3/8 42-7/8 43-3/8 18 18 18 18 18 18 1/2 3/4 1 9 9 9 18 18 18 38-1/2 39 39-1/2 47-1/2 48 48-1/2 16″ IPS 1/2 3/4 1 1-1/2 52-3/4 53-3/4 54-3/4 58 70 50 35 25 15 11 7 5 60 44 28 20 20 20 20 20 20 20 1/2 3/4 1 10 10 10 20 20 20 42-5/8 43-1/8 43-5/8 52-5/8 53-1/8 53-5/8 18″ IPS 1/2 3/4 1 1-1/2 59-1/8 60 61 64-1/4 70 50 35 25 14 10 6 4 56 40 24 16 24 24 24 24 24 24 1/2 3/4 1 12 12 12 24 24 24 51 51-1/2 52 63 63-1/2 64 20″ IPS 1/2 3/4 1 1-1/2 65-3/8 66-3/8 67-3/8 70-1/2 70 50 35 25 12 9 6 4 48 36 24 16 24″ IPS 1/2 3/4 1 1-1/2 77-7/8 78-7/8 79-7/8 83-1/8 70 50 35 25 10 7 5 3 40 28 20 12 8″ IPS *For jobsite application sizing. Not intended for shop fabrication. 12 Throat Meas. Please note: For installing self adhering SA Armaflex sheets and rolls, refer to p.19. Installation: 1. Check the type ell (long or short radius) and size. 5. Trim ends of fitting cover square to meet the straight pipe insulation. Place metal band or metal strap around fitting cover, and scribe a straight line. Then trim with a sharp knife. ▲ Weld 1 ▲ ▲ C/2 ▲ ▲ R2 ▲ ▲ R1 ▲ C/2 2 ▲ Outer arcs ▲ ▲ R1 ▲ 3. Cut out on arcs R1 and R2, and use as a pattern for the second half of the elbow cover. Adhere outer arcs of the two halves with Armaflex 520 or 520 BLV Adhesive. As arcs are adhered, the cover will “dish” upward. After seam is squeezed together on one side, “dish” the cover the opposite direction, and squeeze the other side of seam. R 1 ▲ 2. Take throat measurement from chart (R1). Swing an arc from one corner of the Armaflex sheet, using this measurement. Take half circumference plus throat measurement from chart (R2). Using the same corner of the sheet from which the arc R1 was drawn, now swing an arc, using the measurement R2. ▲ 4. Put cover around elbow fitting, and adhere inner arcs. ▲ 4.c. Armaflex sheet on 90° elbows 3 ▲ ▲ Trim to line Inner arcs 4 5 13 Installation: ment across the throat of the valve at a point under the flange where the stem enters. 4.d. Armaflex sheet on flanged valve fitting covers These instructions are meant to serve as a guide for insulating flanged valves with Armaflex. Because of the variety in shape and design of flanged valves, some modifications to these instructions may be necessary. At this time, the Armaflex donuts at the ends of the fitting should be sealed to the fitting body insulation with 520 Adhesive. ▲ 2. Use scrap strips of Armaflex Sheet to build the body of the valve out until it is the same dimension as the OD of the flanges. Adhere the Armaflex strips directly to the valve body, using 520 or 520 BLV Adhesive. ▲ 1. Cut Armaflex donuts the same diameter as the flanges, and install at pipe/flange and valve stem areas. 5. The Armaflex Sheet, cut out as shown in Figure 4, is installed around the valve body and the joint adhered with 520 Adhesive. This is accomplished by running the adhesive brush between the outer circumference of the Armaflex donut and the inside of the ends of the body insulation (a wet joint). ▲ Armaflex donuts (Same OD as flange) ▲ 1 3. Use a strip of Armaflex Sheet to wrap around the flange to measure the circumference or length of the Armaflex Sheet needed for the valve body. Circumference (Do not stretch) ▲ ▲ 4. Cut Armaflex Sheet for the valve body. A. This length is determined as shown in Figure 3. Build out body 2 3 Adhered ▲ B. This length is obtained by measuring the distance between the outer edges of the Armaflex donuts which are located at the flanges. ▲ C C B ▲ A ▲ 14 ▲ ▲ C. To fit around the valve throat, a semicircle is cut from each end of the Armaflex Sheet. The diameter of semicircle is determined by the measure- Adhered 4 5 Installation: The bonnet insulation may now be installed using 520 or 520 BLV Adhesive to bond the two ends, to adhere the bonnet insulation to the body insulation and to adhere the bonnet insulation around the Armaflex donut. This should complete the flange valve fitting. ▲ Y Y Y ▲ ▲ L2 1/4 C L1 ▲ ▲ ▲ ▲ ▲ ▲ ▲ 1/4 C ▲ ▲ 1/4 C ▲ C 1/4 C ▲ ▲ ▲ ▲ ▲ ▲ 6 L2 The bonnet insulation of Armaflex Sheet is cut to the size of C x L1. This is then marked to show L2 and marked in quarters as shown in Figure 6A. Next the scalloped edge of the insulation is determined by swinging an arc from each point marked + in Figure 6A. The radius of the arc is equal to Y. These arcs are connected with straight lines to give a smooth scalloped edge (see Figure 6B). The scalloped edge of the insulation must be undercut (beveled) to correctly meet the body insulation. ▲ ▲ Bonnet area C—The overall length is determined by wrapping a strip of Armaflex Sheet around the bonnet flange (do not stretch) and marking where the ends meet. L1—This distance is obtained by measuring from the outer surface of the Armaflex donut to the approximate middle of the valve body insulation. L2—This distance is obtained by measuring from the outer surface of the Armaflex donut to the closest surface of the valve body insulation. Y—is the difference between L1 and L2. ▲ ▲ L1 Figure 6A. The measurements for Figure 6A are determined as follows: ▲ The last piece of insulation needed will insulate the bonnet area. This is shown in Figure 6 and is made as shown in ▲ 6. 6A 6B 15 Please note: For installing self adhering SA Armaflex sheets and rolls, refer to p.19. Installation: Armaflex sheet on metal ductwork The preferred method for square and rectangular ducts is to cut and fit the sheets, using full coverage of Armaflex 520 or 520 BLV Adhesive to adhere the insulation. 1. Measure—Sheets should be sized with the following application sequence in mind. Cut the bottom piece first, making it the same width as the duct. Then cut the two side pieces, so that they extend down over the edges of the bottom insulation; keep top edges flush with the top of the duct. The top insulation should be sized so that it extends over the side insulations. The fabrication must be done at the job site, at the same ambient conditions as the application. 2. Cut—A sharp knife and a straightedge are the only tools required. Armaflex Sheet cuts cleanly. 3. Apply Adhesive—First brushor roller-coat 520 or 520 BLV Adhesive on the metal duct surface. Then coat the back side of the Armaflex Sheet, leaving a 1/2″-wide uncoated border at butt-edge seams. Allow the adhesive to dry to the touch but still tacky under slight pressure before joining surfaces. in this position, and spot-adhere it in the center. Compress the butt edges into place for a tight joint with adjoining sheets. Then bond the remainder of the sheet by pressing it firmly into place. A small hand roller will help apply pressure. 5. Adhere Joints—Spread the joint, and with a small brush, apply 520 or 520 BLV Adhesive to both butt edges. Do not flood joint with adhesive. Align carefully for good appearance, and apply pressure to joint. 6. Standing Seams—These can be insulated with strips of Armaflex Sheet, generally cut from scrap. 8. Apply WB Armaflex Finish— Two coats of WB Armaflex Finish, a white water-based latex enamel coating, are all that is required to provide a protective finish for outdoor installations. WB Armaflex Finish can be brush- or rollerapplied. 1 2 3 4 5 6 7 8 4. Bond—Position the sheet so that it overlaps the edges of previously installed sheet or sheets by 1/8″. Hold the sheet 16 7. Alternate Method—Standing seams can also be insulated with half sections of Armaflex Pipe Insulation, corresponding in thickness to the sheet used on the duct surface. Ends should be miter-cut to insure tight fit when bonded. Please note: For installing self adhering SA Armaflex sheets and rolls, refer to p.19. Installation: Flexible ArmaTuff Plus, ArmaTuff White or ArmaTuff Silver can be used for all exterior applications. They are practical also for use on exterior ducts, tanks, vessels, large pipes and fittings. The material provides a durable, tough and maintenance-free surface. The material is resistant to UV, ozone, acid rain and most industrial pollutants. No painting is required. The recommended temperature usage range for ArmaTuff is -70°F to 180°F (-57°C to 82°C). The closed cell structure of ArmaTuff insulation effectively retards the flow of water vapor, and it is considered a low transmittance vapor retarder. ArmaTuff does not require additional vapor retarder. The white surface reflects heat to reduce energy load. ArmaTuff is designed for installation in above ground applications. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. Applying Non-Self Adhering ArmaTuff Sheets 1. Always prepare surface by cleaning with denatured alcohol. ArmaTuff is installed using Armaflex 520 or 520 BLV adhesive or with pre-applied pressure sensitive adhesive (PSA). For application to large, flat or curved 2. Insulate sides first. Apply metal surfaces such as ducts, thin, uniform coat of Armaflex 520 or 520 BLV vessels, very large pipes or tanks, Adhesive. full Armaflex 520 or 520 BLV adhesive coverage or product with PSA is used. The seams must be installed in compression and sealed with Armaflex 520 or 520 BLV Adhesive. Cover the seam with 4″ and exposed edges with 4″ or 6″ ArmaTuff Seal Tape. Armaflex 520 or 520 BLV adhesive is a contact adhesive: therefore it must be applied to both surfaces, allowed to get tacky, 3. Roll thin coat of 520 or and the surfaces are joined with 520 BLV Adhesive to insulation. pressure. 4. Position carefully and apply ArmaTuff. Contact adhesive bonds instantly. 5. Apply ArmaTuff to top surface, overlapping the side pieces. 6. Seal and protect exposed edges and seams with ArmaTuff Seal Tape. 17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Create Date : 2006:01:16 13:40:54-05:00 Creator Tool : QuarkXPressª 5.0.1: LaserWriter 8 8.7.1 Modify Date : 2006:01:20 14:22:05-05:00 Metadata Date : 2006:01:20 14:22:05-05:00 Format : application/pdf Creator : Title : 000.005 Install Man B&W Producer : Acrobat Distiller 5.0.5 for Macintosh Document ID : uuid:77b03c5d-4b6e-4fc2-a22e-3fe4194b283d Instance ID : uuid:a9f9a4ed-1ad2-436a-8852-9d2783f46055 Has XFA : No Page Count : 9 Author :EXIF Metadata provided by EXIF.tools