TYPE DESCRIPTION LAMP MANUF. VOLT. TOTAL WATTS BALLAST A1 2X4 RECESSED, LENSED, GRID CEILING, STATIC, FLUSH STEEL DOOR, TRIPLE GASKETING, STEEL HOUSING WITH WHITE ENAMEL, SPEC. GRADE (2) F32T8/35000K LITHONIA SP8 120 73 ELECTRONIC RAPID START 120 67 DIMMING 120 232 MH DUAL 120 326 MH DUAL 6" SQUARE RECESSED DOWNLIGHT, CLEAR SPECULAR REFLECTOR DIRECTIONAL RECESSED DOWNLIGHT, DIE CAST ALUMINUM OPTICAL ASSEMBLY DIRECTIONAL RECESSED DOWNLIGHT, DIE CAST ALUMINUM OPTICAL ASSEMBLY DIRECTIONAL RECESSED DOWNLIGHT, DIE CAST ALUMINUM OPTICAL ASSEMBLY (2) F32TBX/3000K 4PIN KURT VERSON (2) PAR30 35MH/3000K + (2) AR111 75W/3000K (2) PAR30 70MH/3000K + (2) AR111 75W/3000K SISTEMA 8240MH30 SISTEMA 8240MH70 (2) AR111 75W/3000K SISTEMA 8220-AR 120 150 NA B5 CYLINDRICAL DOWNLIGHT, PENDANT MOUNTED, CLEAR ALZAK REFLECTOR, BLACK FINISH, MOUNTING HEIGHT 10' FROM FLOOR (1) F32TBX/3000K 4 PIN DELRAY CP8100 120 32 DIMMING B6 DECORATIVE 9"X9" SQUARE DOWNLIGHT, CLEAR ACRYLIC FINISH WITH TRANSLUCENT DIFFUSED COATING (2) 32WTBX/3000K LIGHTOLIER SL207A 120 67 ELECTRONIC RAPID START B7 4" LOW VOLTAGE DOWNLIGHT, OPEN CLEAR CONE, SPECULAR LOW IRIDESCENT FINISH, LENS OPTION (1) 20WMR16 FL GOTHAM DLV 120 20 NA B8 1" RECESSED DOWNLIGHT, LENSED PINHOLE, FLOOD DISTRIBUTION (1) 20WMR16 FL GOTHAM DLV 120 20 NA D1 CUSTOM DECORATIVE CHANDELIER, FROSTED SQUARE LAMP SHADE, SQUARE SHAPE, COVE FOR HOUSING CEILING HIGHLIGHT FIXTURES, DARK BRONZE FINISH (108) 40W HALOGEN G9 FROSTED SEE DETAIL 120 4320 NA D2 DECORATIVE PENDANT, BRONZE FINISH, CLEAR AND FROSTED GLASS DIFFUSER (1)40W HALOGEN G9 FROSTED ZANEEN D4-1027 120 40 NA O1 SPHERE SHAPED DIE-CAST ALUMINUM HOUSING, PRISMATIC GLASS LENS, RECTANGULAR WIDE DISTRIBUTION, DARK BRONZE FINISH, UL LISTED FOR WET LOCATIONS, FOUR FIXTURE HEADS, ONE MOUNTED AT 19'-8", ONE AT 18'-8", TWO MOUNTED ON SIDES AT 17'-8" (1) PAR56 100MH/3000K STERNER CALLISTOR-12 120 125 MH DUAL O2 LIGHT SPOT WITH 9 LED IN STAINLESS STEEL, OPAL OPTIC COVER, TRANSFORMER INCLUDE IN FIXTURE (9) WHITE LEDS INCLUDED WITH FIXTURE ANSORG LED DOT 24 2 NA O3 COMPACT LINE VOLTAGE FIXTURE, FULLY ADJUSTABLE MOUNTING, SIPHONE PROTECTION SYSTEM, BRONZE FINISH, LANDSCAPE ACCENT, UL LISTED FOR WET LOCATIONS (1) PAR20 50W LUMIERE CORONADO 806 120 50 NA O4 RERCESSED INGRADE WELL UPLIGHT FIXTURE, CAST BRONZE DOOR, SPOT DISTRIBUTION, DOUBLE LENS, UL LISTED FOR WET LOCATION (1) PAR56 100MH ED17/3000K HYDRELL M9700 120 125 MH DUAL O5 INDIRECT RECESSED HOLE IN THE WALL LIGHT NICHE FOR EXTERIOR STUCCO CONSTRUCTION, UL LISTED FOR WE LOCATIONS (1) F32TBX/3000K 4 PIN ENGINEERED LIGHT PRODUCTS HITW-EX 120 36 ELECTRONIC RAPID START B1 B2 B3 B4 O6 FLEXIBLE LED COMPACT LINEAR RAIL FIXTURE, CLEAR POLYCARBONATE LENS, 8' SECTIONS, UL LISTED FOR WET LOCATIONS, INCLUDE TRANSFORMER LED OPTION ARDEE CLM 12 48 48 O7 SPHERE SHAPED DIE-CAST ALUMINUM HOUSING, PRISMATIC GLASS LENS, RECTANGULAR WIDE DISTRIBUTION, DARK BRONZE FINISH, UL LISTED FOR WET LOCATIONS, TWO FIXTURE HEADS, ONE MOUNTED AT 15'-8", ONE MOUNTED AT 14'-8" (1) PAR56 70MH/3000K STERNER CALLISTOR-12 120 88 MH DUAL NA STERNAR RTS NA NA NA NA STERNAR RTS NA NA NA P1 P2 ROUND TAPERED STELL POLE, DARK BRONZE FINISH, 20' POLE HEIGHT ROUND TAPERED STELL POLE, DARK BRONZE FINISH, 16' POLE HEIGHT T1 8" OPEN TRACK FIXTURE, DIFFUSE ALLUMINUM REFL., WIDE FLOOD DISTRIBUTION (1) PAR30 70MH/3000K LITHONIA LTD REFL 120 85 MH SINGLE T2B SURFACE MOUNTED 120V TRACK SYSTEM, 4' SECTIONS, BLACK FINISH NA NORDIC ALUMINUM 120 NA NA T3 LOW VOLTAGE DECORATIVE SPOT, SURFACED MOUNTED, WHITE FNISH, SQUARE SHAPED (1)75W HALOGEN MR20 ZANEEN D9-2018 120 75 NA A1 Specification Premium T8 Troffers Lensed Troffers Intended Use Standard latch provides spring action. Door latches and hinges from either side. Specification premium, high performance, static T8 luminaires provide general illumination for recessed applications; ideal for restricted plenum spaces. SP8 Improved performance – higher fixture efficiency and reduced lamp image. Static Integral T-bar safety clips are standard – no need to install separate clips. Features Aluminum door frames available, flush or regressed. Innovative low-profile design optimized around T8 lamps, low-profile electronic ballasts and T8 compact sockets. Compatible with virtually all ceiling types. Field trim modification kits also available. See page 48. Hemmed sides provide smooth edges for easy handling during installation. U.S. patents – 6,210,025; 6,231,213; 6,213,625; 2,288,471. Standard steel door frame features precise flush-mitered corners. Listings – UL Listed (standard). CSA Certified or NOM Certified (see Options). Unique door frame design delivers a premium extruded appearance. Housing and door frame interface provides a superior mechanical light seal without the use of foam gasketing. Ordering Information Series 2SP8 2' wide Example: 2SP8 G 3 32 A12 120 1/3 GEB Frame type Number of lamps 2, 3, 41, 61 Not included. Trim type G Grid F Flanged MT Modular fit-in Lamp type 17 17W T8 (24") U31 31W T8 U (15/8" leg) U316 31W T8 U (6" leg)2 32 32W T8 (48") CF39 39W TT5 (16") CF40 40W TT5 (24") CF50 50W TT5 (24") CF55 55W TT5 (24") Voltage (blank) Flush steel, white FN Flush aluminum, natural FM Flush aluminum, matte black FW Flush aluminum, white RN Regressed aluminum, natural RM Regressed aluminum, matte black RW Regressed aluminum, white NOTES: 1 4- and 6-lamp models available with 17W and 32W straight tubes only. 2 Not available on 3-lamp fixtures. Use U31. 3 Standard A12 diffuser has reverse apex technology. Options 1/3 1/4 GEB 120 277 347 MVOLT* Others available. GEB10IS * 120-277V. Must specify GEB10IS. GEB10RS CSA NOM One 3-lamp ballast One 4-lamp ballast Electronic ballast, <20% THD T8 electronic ballast, <10% THD, instant start T8 electronic ballast, <10% THD, rapid start CSA Certified NOM Certified See pages 90 & 91 for others. Diffuser type A12 A12125 RA125 A19 K20 84Y PC1S PC2S PC3S #12 pattern acrylic3 #12 pattern acrylic, .125" thick #12 pattern acrylic, .125" thick (reverse apex) #19 pattern acrylic, .156" thick #20 pattern acrylic, .140" thick Holophane 8224 with overlay ½"x½"x½" plastic cube louver, silver 1½"x1½"x1" plastic cube louver, silver with flange ¾"x¾"x½" plastic cube louver, silver Availability and Dimensions Nominal Size 2x2 2x4 Series 2SP8 2SP8 2SP8 2SP8 2SP8 2SP8 Number of Lamps 2 2 3 3 4 2, 3, 4, 6 Lamp Type 17, U31, U316, CF39 CF40, CF50, CF55 17, U31, CF39 CF40, CF50, CF55 17 32 Height in.(cm) 311/16 (9.3) 311/16 (9.3) 311/16 (9.3) 311/16 (9.3) 311/16 (9.3) 311/16 (9.3) www.lithonia.com keyword: SP8 Fluorescent / PSG8 35 Universal Start Fluorescent Lamps 32 Watts Bulb T8 Base Med. Bipin Product Number 0... Page 1 of 2 A1 Universal Start Fluorescent Lamps Feature T8 Medium Bipin featuring HIVISION® Phosphor Watts 32 Bulb T8 Base Med. Bipin Product Number 046677-27274-0 Ordering Code F32T8/TL735/ALTO UPC Package Quantity 25 Description TL 735, 3500K CRI 78 Design Lumens 2710 Nominal Length 48 Approximate Initial 2850 Lumens Rated Avg. Life 20,000 (Hrs.), 3-Hr. Start Rated Avg. Life 20,000 (Hrs.), 12-Hr. Start Images Literature Other Information + Family Photo + Family Brochure • Energy Saving Product + Product Logo + MSDS S09-98001 • Meets US Federal Minimum + Product Photo Efficiency Standard + Printable Page + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + Rated average life under specified test conditions with Programmed Start ballasts with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate Ballast Factor for each of their ballasts when they are informed of the designated lamp. The Ballast http://www.nam.lighting.philips.com/us/ecatalog/fluor/displayfluor.php?id=107 4/3/2005 Universal Start Fluorescent Lamps 32 Watts Bulb T8 Base Med. Bipin Product Number 0... Page 2 of 2 Factor is a multiplier applied to the designated lamp lumen output. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. + Universal T8 lamps have full rated life on Instant Start, Rapid Start and Programmed Start ballasts. + + Features ALTO® Lamp Technology High Color Rendering Lamps (CRI 70-79) Information for this product last modified on November 20 2002. ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/fluor/displayfluor.php?id=107 4/3/2005 A1 R-2P32-TP Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status Electrical Specifications Lamp Type Num. of Lamp s 2 2 * F32T8 F32T8/U Rated Lamp Watts Min. Start Temp (°F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor B.E.F. 32 31.2 50/10 50/10 0.64 0.64 73 73 0.94 0.94 10 10 0.97 0.97 1.4 1.4 1.29 1.29 Wiring Diagram LINE BLACK WHITE YELLOW YELLOW MARK III Magnetic Rapid Start Series 120 60 HZ Active Enclosure BLUE BLUE RED RED BALLAST H LAMP W LAMP M L CASE "T" Diag. 21 The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Enclosure Dimensions Standard Lead Length (inches) Black White Blue Red Yellow Gray Violet in. 20 20 24 24 36 cm. 50.8 50.8 61 61 91.4 0 0 in. Yellow/Blue Blue/White Brown Orange Orange/Black Black/White Red/White cm. 0 0 0 0 0 0 0 OverAll (L) 9.50 " 9 1/2 24.1 cm Width (W) 2.375 " 2 3/8 6 cm Height (H) Mounting (M) 1.5 " 8.90625 " 1 1/2 8 29/32 3.8 cm 22.6 cm Revised 08/14/2003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 Section H fronts_UG 12/6/02 11:58 PM Page 15 B1 Socket Bracket Alzak Reflector Lamp (By Others) Vented Top Venting Slot Vertical Safety Full Lens Trim Square Aperture Trim Adjustment Chain (Optional) Frame Rail Support (2) Cone Retaining Spring H8643 H23 Shallow Depth, Wide Beam Downlight One 26-32-42W Triple Tube Compact Fluorescent 6" Square Parabolic Trim Custom (2) 32W Triple Tube Compact Fluorescent, consulted manufacture. Optics and Applications The socket is mounted horizontally in an ellipsoidal primary reflector for wide distribution and reduced recess depth in shallow plenums. Use in low to medium height ceilings for corridors, entries and for general and area lighting. Design Features A steel housing protects and aligns reflectors and lamps. The socket and ballast will accept all triple tube wattages interchangeably. The square trim is stabilized by a proprietary steel web to prevent racking and is held to the ceiling by constant pressure springs. Maximum ceiling thickness 11/2". Ballast and lamp service from below. Finish Housings and structural parts are painted matte black to suppress stray light leaks. Standard trims are anodized Softglow® clear. Special finishes, textures and colors are available, see below under Accessories. Trim Textures Textured trims create a subtle new aperture appearance. Select among different embossed patterns to match the ambiance of the space being illuminated. Refer to Squares brochure for descriptive photos. Dimensions and Lamps D General Fixtures are pre-wired, UL and C-UL listed for eight wire 75°C branch circuit wiring. Union made IBEW. Luminaire Efficiency Rating (LER) data is in the photometric directory located in Section Z. A B A Number Depth 1 H8643 C B C Aperture Width 6 " sq. 6 /2" 165mm 153mm D Length Lamps 1 13 /2" 19" 26-32-42W TripleTube 343mm 483mm compact fluorescent Brightness Number Lamps 85° 75° 65° 55° 45° H8643 32W T/E Osram/Syl 32W PL-T Philips 42W PL-T Philips 42W T/E Osram/Syl 31 37 40 53 97 108 151 185 203 218 273 367 1221 6698 6857 4566 10019 13729 19941 17420 Data in footlamberts. Photometer readings, Maximum Brightness Method. Matching Square Units Vertical lamp fluorescent Low voltage PAR lamps Directional Halogena, A lamps Tungsten halogen Metal halide Wall washer Page Pages Pages Page Page Page Pages Page Ballasts Fully electronic, microprocessor controlled with programmed start to assure rated lamp life. Input voltage ranges from 120V through 277V. Operates 26, 32 or 42W lamps interchangeably. Power factor .98, starting temperature 0°F (-18°C), THD<10%. Pre-heat start < 1.0 second. End of lamp life protection. Rated for > 50,000 starts. H22 H5, H6 H7, H8, H9 H9 H10 H11 H26, H27, H28 H37 Accessories R2 26" support rails. WT White trim flange. WHT White complete trim. R5 52" support rails. SB Softglow black. BP Ball Peen texture. SG Softglow gold. CG Corrugated texture. SH Softglow mocha. DS Distressed texture. SP Softglow graphite. WV Woven texture. ST Softglow titanium. LL Linear spread lens. SW Softglow wheat. LP Large prism lens. SY Softglow pewter. MP Microprism lens. V347 347 volt ballast. SZ Softglow bronze. BR Bright trim finish. FC Four cell cross baffle. FR Frosting on lens. DM Dimming ballast. F Fuse. Specify watts and volts. EM Emergency power includes integral charger light and test switch visible through aperture. Battery operation for 90 minutes. FLT6 Full lens trim, specify lens type, e.g. H8643-FLT6LL. WRL Wattage restriction label, specify wattage. Kurt Versen Company Point Source Lighting Westwood, New Jersey 07675 Section H backs_UG 12/3/02 1:43 AM Page 15 H23 H8643 Performance Datachart Single Unit Initial Footcandles, 30" Work Plane Ceiling to Floor Multiple Units Initial Footcandles, 30" Work Plane H8643 One 32W Philips Triple Tube Read Top Data H8643 One 42W Philips Triple Tube Read Bottom Data 10° Nadir 20° Ceiling 80% 30° Walls 50% Floor 20% Spacing is Maximum Over Work Plane FC FC Diam FC Diam FC Diam Spacing RCR 1 RCR 3 RCR 8 19 29 18 27 2' 2' 16 21 4' 4' 10 13 6' 6' 8' 7' 6' 23 38 19 32 15 21 21 18 13 19 2' 2' 11 15 5' 5' 7 10 8' 8' 9' 8' 7' 16 27 14 23 11 15 10 16 10 14 3' 3' 8 11 5' 5' 5 7 9' 9' 10' 9' 8' 12 20 10 17 8 11 8 12 8 11 3' 3' 7 9 6' 6' 4 6 10' 10' 11' 10' 9' 10 16 8 14 6 9 6 10 6 9 3' 3' 5 7 7' 7' 3 4 11' 11' 12' 12' 10' 8 13 6 11 5 7 Candlepower Distribution 85° 60 ° 75° 120 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 65° 180 55° 240 45° 300 360 35° 420 90° 480 0° 540 600 5° 15° 25° H8643 One 32W Triple Tube Philips Eff. 39% S/M 0° 1.30 S/M 90° 1.14 ° * ° 75° 176 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 65° 264 55° 352 45° 440 528 35° 616 0° 704 90° 792 880 5° 15° 25° H8643 One 42W Triple Tube Philips Eff. 38% S/M 0° 1.07 S/M 90° 1.06 ° * 0° 90° 2400* 2400* 48 560 561 568 585 588 558 521 455 358 256 165 92 22 9 0 0 0 0 0 560 565 579 581 567 516 431 359 283 194 124 59 21 12 0 0 0 0 0 96 Vertical Angles Initial Lamp Lumens 85° 88 See notes 2, 3 and 4. Candelas 55° 192 288 336 35° 90° 384 0° 432 480 5° 15° 25° H8643 One 32W Triple Tube Osram Sylvania Eff. 33% S/M 0° 1.36 S/M 90° 1.24 90° 75 880 866 842 813 768 694 619 508 386 266 172 107 50 19 0 0 0 0 0 880 869 843 816 781 710 602 461 322 235 173 113 50 17 0 0 0 0 0 150 Kurt Versen Company, Westwood, New Jersey 45° 240 3200* 1 Softglow® cone multipliers: Gold x .89, Wheat x .87, Pewter x .73, Mocha x .75, Graphite x .70, Titanium x .70, Bronze x .68. 2 Single unit Datachart pattern diameters are determined by the number of degrees from each side of nadir. Therefore a 20° diameter represents a total 40° pattern width at the work plane 30" above the floor. Footcandle values are at the edge of that diameter. 3 Datachart spacing is rounded off to the nearest foot. 4 Data by IES methods. Compact fluorescent data vary due to lamp lumen differences, power input, burning position, ambient temperature and ballast characteristics. A modification factor should be applied. 5 Brightness data from the Average Luminance Method are inaccurate for small aperture downlights. They are theoretical calculations derived for large surfaces such as troffers. For a complete discussion refer to section Z brochure Z1. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 65° 144 0° Notes ° 75° 3200* Vertical Angles Initial Lamp Lumens 85° ° 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 65° 225 55° 300 45° 450 35° 90° 600 0° 675 750 5° 15° 25° H8643 One 42W Triple Tube Osram Sylvania Eff. 35% S/M 0° 1.21 S/M 90° 1.13 457 466 464 469 475 448 457 396 316 233 136 52 13 8 6 0 0 0 0 457 460 470 476 473 452 399 337 255 170 99 34 14 9 7 0 0 0 0 * 75° 525 90° 2400* Vertical Angles ° Initial Lamp Lumens 85° 375 0° 2400* 0° 90° 3200* 3200* 757 750 751 746 725 718 632 529 408 288 185 102 40 15 0 0 0 0 0 757 761 741 704 647 625 569 454 315 194 128 81 36 15 0 0 0 0 0 Vertical Angles ° Initial Lamp Lumens * Coefficients of Utilization Ceiling 80% Wall % 70 RCR 50 30 70% 10 50 10 50% 50 10 30% 0 50 10 0 Zonal Cavity Method - Floor Reflectance 20% 1 .43 .41 .40 .39 .41 .39 .39 .38 .38 .36 .35 2 .40 .38 .36 .35 .37 .34 .36 .34 .35 .33 .31 3 .38 .35 .33 .31 .34 .31 .33 .30 .32 .30 .29 4 .35 .32 .30 .28 .32 .28 .31 .27 .30 .27 .26 5 .33 .29 .27 .25 .29 .25 .28 .25 .28 .24 .24 6 .31 .27 .25 .23 .27 .23 .26 .22 .26 .22 .22 7 .29 .25 .23 .21 .25 .21 .24 .21 .24 .20 .20 8 .28 .23 .21 .19 .23 .19 .23 .19 .22 .19 .18 9 .26 .22 .19 .18 .22 .18 .21 .17 .21 .17 .17 10 .25 .20 .18 .16 .20 .16 .20 .16 .20 .16 .16 H8643 One 42W Philips H8643 One 32W Philips x 1.00 H8643 One 42W Osram x .93 H8643 One 42W Osram x .86 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 1 of 2 B1 PL-T Triple 4-Pin Fluorescent Lamp Feature High color rendering, high efficacy lamps feature 4-pin base for use with preheat, rapid start, electronic and dimming circuits. Featuring ALTO® Lamp Technology Watts 32 Bulb PL-T Base GX24q-3 Product 046677-26832-6 Number Ordering PL-T 32W/830/4P/ALTO Code Generic CFTR32W/GX24q/830 Designation Package 12 Quantity Description 3000K CRI 82 Avg. Hrs. 10,000 Life Design 2040 Lumens M.O.L. 5 5/8 Lumens 2400 Images Literature Other Information + ALTO Product Logo + ALTO Family Brochure • Energy Saving Product + Family Photo + MSDS S08-98001 + Printable Page + Product Photo + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + This Product Contains Amalgam + High Color Rendering Lamp Features ALTO® Lamp Technology + Rated average life under specified test conditions with Programmed Start ballasts with lamps + turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 2 of 2 + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. Information for this product last modified on September 25, 2001 ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 B1 IZT-2T42-M3-BS@120 Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status Electrical Specifications Lamp Type * CFM32W/GX24Q CFM42W/GX24Q CFTR57W/GX24Q CFTR70W/GX24Q Num. of Lamp s 2 2 1 1 Rated Lamp Watts Min. Start Temp (°F/C) 50/10 50/10 50/10 50/10 32 42 57 70 MARK VII 0-10V Electronic Dimming Programmed Start Series 120-277 50/60 HZ Active Input Current (Amps) Input Power (Watts) (min/max) Ballast Factor (min/max) MAX THD % Power Factor Lamp Current Crest Factor B.E.F. 0.63 0.82 0.55 0.67 19/75 18/98 18/66 18/80 0.05/1.00 0.05/1.00 0.05/1.00 0.05/1.00 10 10 10 10 0.99 0.99 0.99 0.99 1.4 1.4 1.7 1.7 1.33 1.02 1.52 1.25 Wiring Diagram Enclosure WIRING: (2) TRIPLE LAMPS LINE CLASS 1&2 CIRCUIT 10V, 0.5mA BLACK WHITE VIOLET (+) GREY (-) GREEN BLUE BALLAST Y E L L O W RED Green Terminal must be Grounded The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Enclosure Dimensions Standard Lead Length (inches) Black White Blue Red Yellow Gray Violet in. 0 0 0 0 0 0 0 cm. 0 0 0 0 0 0 0 in. Yellow/Blue Blue/White Brown Orange Orange/Black Black/White Red/White cm. 0 0 0 0 0 0 0 OverAll (L) 6.28 " 6 7/25 16 cm Width (W) 3.00 " 3 7.6 cm Height (H) Mounting (M) 1.29 " 2.00 " 1 29/100 2 3.3 cm 5.1 cm Revised 08/27/2003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 IZT-2T42-M3-BS@120 Electrical Specifications Notes: Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status MARK VII 0-10V Electronic Dimming Programmed Start Series 120-277 50/60 HZ Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements. 1.3 Ballast shall be provided with poke-in wire trap connectors or integral leads color coded per ANSI C82.11. Section II - Performance Requirements 2.1 Ballast shall be Programmed Start. 2.2 Ballast shall be provided with integral protection circuitry to withstand connection of low voltage control leads to mains power supply. In this event, ballast shall default to maximum light output. 2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.4 Ballast shall operate from 50/60 Hz input source of 120V or 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. IntelliVolt models shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. 2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker. 2.6 Ballast shall have a Power Factor greater than 0.98 at full light output and greater than 0.90 throughout the dimming range for primary lamp. 2.7 Ballast shall have a maximum ballast factor of 1.00 (1.18 for HL versions) at maximum light output and 0.03 at minimum light output for primary lamp application. 2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less throughout the dimming range in accordance with lamp manufacturer recommendations. 2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.10 Ballast shall have a Class A sound rating. 2.11 Ballast shall have a minimum starting temperature of 10C (50F) for primary lamp. 2.12 Ballast shall provide Lamp EOL Protection Circuit for all T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp ballast. 2.13 Ballast shall control lamp light output from 100% - 3% relative light output for T8 and CFL lamps and 100% - 1% relative light output for T5/HO lamps. 2.14 Ballast shall ignite the lamps at any light output setting without first going to another output setting. 2.15 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. Section III - Regulatory Requirements 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 Ballast shall comply with ANSI C82.11 where applicable. 3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated). Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 70C. 4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. 4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage 0-10VDC controller. 4.5 Ballast shall be Advance Transformer part # _____________ or approved equal. Revised 08/27/2003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD ROSEMONT, ILLINOIS 60018 TELEPHONE: (847) 390-5000 FAX: (847) 390-5109 B2 20 MULTIPLE LARGE Toronto University Architecture Dept. 21 MULTIPLE LARGE (MH) 8-7/8" Multiple Large Four 8240-AR 4 x AR 111 75 W 8240-PAR 4 x PAR 30 75 W 8240-MH35 2 x AR 111 75 W + 2 x Metal Halide PAR 30 35 W (PAR/AR) 7-3/8" Newtown restaurant, Foti & Drouin designers 8240-MH70 Fixture to be oriented linearly as 12-5/8" x 12-5/8" multiply large six below but with 4 lamps. 13-3/4" 8240-4MH35 4 x Metal Halide PAR 30 35 W 2 x AR 111 75 W + 2 x Metal Halide PAR 30 70 W 8240-4MH70 4 x Metal Halide PAR 30 70 W 8340-PAR 4 x PAR 38 90W 8340-MH 4 x Metal Halide PAR 38 70W 13-3/4" 6 x PAR 30 75 W 8260-MH35 4 x AR 111 75 W + 2 x Metal Halide PAR 30 35 W 8260-MH70 4 x AR 111 75 W+ 2 x Metal Halide PAR 30 70 W 8360-PAR 6 x PAR 38 90 W 8360-MH 2 x Metal Halide PAR 38 70W + 7-1/4" 6 x AR 111 75 W 8260-PAR (PAR/AR) 7-3/8" 8260-AR (MH) 8-7/8" Multiple Large Six 6-1/2" x 38" 39" 4 x PAR 38 90 W ACCESSORIES FOR MULTIPLE LARGE 1" 8211 Cross Baffle for PAR 30 These are standard configurations. Custom configurations available upon request. 8311 Cross Baffle for PAR 38 8812 for PAR, AR 111 00 frosted 05 red 06 yellow 09 blue 24 clear 10 Protected MasterColor Ceramic Metal Halide Lamp 39 Watts Bulb PAR-30L Base Med. ... Page 1 of 2 B3 Protected MasterColor® Ceramic Metal Halide Lamp Feature PAR Style. Open or Enclosed Luminaires. Lifetime Color Stability Within +/- 200K Watts 39 Bulb PAR-30L Base Med. Product Number 046677-22330-5 Ordering Code CDM35/PAR30L/M/FL Package Quantity 6 Description G, PAR WISO Flood 30 degrees FadeBlock 7400 MBCP ANSI M130/O Code/Ballast Ref. CRI 81 Rated Avg. Life 9000 (Hrs.) M.O.L. 4 3/4 Approximate 2200 Initial Lumens Approximate 1760 Mean Lumens CCT 3000 Images Literature Other Information + Family Photo + Family Brochure + Printable Page + Product Logo + MSDS S15-95005 + View Compatible Ballasts + Product Photo + Photometric Data + Technical Data Sheet + Send this Link + Bookmark this Page † Heat resisting glass bulb Footnotes MasterColor® Metal Halide Lamps are not recommended for use on dimmers and are not warranted if used on dimmer systems. + + "Operate only on thermally protected ballasts" UV filtered design (Fade-Block™). + Click here for Recommended Warnings, Cautions and Operating Instructions. + + Supply volts must be +/- 5% of rated ballast line volts for reactor type and +/- 10% for CWA or electronic ballasts. + Requires a ballast specified or approved for Philips Metal Halide lamp or one designed to the http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=26 4/3/2005 Protected MasterColor Ceramic Metal Halide Lamp 39 Watts Bulb PAR-30L Base Med. ... Page 2 of 2 indicated ANSI Standard. A pulse ignitor is required. Sockets and wiring must withstand starting pulse. + Approximate lumen output at 40% of lamp rated average life. + Approximate lumen values listed are for vertical operation of the lamp. + Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps. + ANSI CODE RATING, E - Enclosed, O - Open, S - Open or Enclosed + Click here for specific product and ordering information on this lamp. + Heat resisting glass bulb + Excellent color rendition - up to 92 CRI Information for this product last modified on June 22 2004. ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=26 4/3/2005 B2 Metal Halide Lamp Ballast Catalog Number 71A50Y1 For 39W M130 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 3 X 4 CORE - 2 COIL UNIT 5.10 " 4.50" 0.7" 1.0" A B MAX. 0.25" WIDE 2 SLOTS 3.95" 3.50" 4 HOLES CLEARED FOR #10 THRU-BOLTS 2.45" 2.80" Capacitor: 7C100M30-R 2.90" INPUT VOLTS 100 200 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±10% Lamp Watts LINE CURRENT (Amps) Operating................................................... 0.56 0.28 Open Circuit............................................... 1.30 0.70 Starting...................................................... 0.50 0.25 UL TEMPERATURE RATINGS Insulation Class H(180°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -30°F or -35°C NOM. OPEN CIRCUIT VOLTAGE 248 INPUT VOLTAGE AT LAMP DROPOUT........................... 70 140 INPUT WATTS 53 RECOMMENDED FUSE (Amps)..................................... 3 2 CORE and COIL Dimension (A) 0.85 Dimension (B) 1.95 Weight (lbs.) 3 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads 10.0 Volts (min.) 280 Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 1500 2 seconds 2500 Open Circuit Voltage Test (Volts) 223-273 Short-Circuit Current Test (Amps) Secondary Current 0.60-0.74 Input Current.............................................. 0.38 0.19 0.58 0.29 - - - Wiring Diagram: LAMP CAP LINE V LINE V X3 X1 IGNITOR CAP LAMP LINE V X2 COM LINE V Capacitance: Dia/Oval Dim: Height: Temp Rating: 10 1.5 2.9 105°C COM COM Fig. K Ordering Information Ignitor: LI533-H4 Order Suffix 500D. Description Ballast With Ignitor and Dry Film Capacitor Ballast to Lamp Distance (BTL) = 5 feet Temp Rating: 105°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 04/15/02 B2,B3,B4 B3 20 MULTIPLE LARGE Toronto University Architecture Dept. 21 MULTIPLE LARGE (MH) 8-7/8" Multiple Large Four 8240-AR 4 x AR 111 75 W 8240-PAR 4 x PAR 30 75 W 8240-MH35 2 x AR 111 75 W + 2 x Metal Halide PAR 30 35 W (PAR/AR) 7-3/8" Newtown restaurant, Foti & Drouin designers 8240-MH70 Fixture to be oriented linearly as multiply large six below, but with four 12-5/8" x 12-5/8" lamps. 13-3/4" 8240-4MH35 4 x Metal Halide PAR 30 35 W 2 x AR 111 75 W + 2 x Metal Halide PAR 30 70 W 8240-4MH70 4 x Metal Halide PAR 30 70 W 8340-PAR 4 x PAR 38 90W 8340-MH 4 x Metal Halide PAR 38 70W 13-3/4" 6 x PAR 30 75 W 8260-MH35 4 x AR 111 75 W + 2 x Metal Halide PAR 30 35 W 8260-MH70 4 x AR 111 75 W+ 2 x Metal Halide PAR 30 70 W 8360-PAR 6 x PAR 38 90 W 8360-MH 2 x Metal Halide PAR 38 70W + 7-1/4" 6 x AR 111 75 W 8260-PAR (PAR/AR) 7-3/8" 8260-AR (MH) 8-7/8" Multiple Large Six 6-1/2" x 38" 39" 4 x PAR 38 90 W ACCESSORIES FOR MULTIPLE LARGE 1" 8211 Cross Baffle for PAR 30 These are standard configurations. Custom configurations available upon request. 8311 Cross Baffle for PAR 38 8812 for PAR, AR 111 00 frosted 05 red 06 yellow 09 blue 24 clear 10 Protected MasterColor Ceramic Metal Halide Lamp 70 Watts Bulb PAR-30L Base Med. ... Page 1 of 2 B3 Protected MasterColor® Ceramic Metal Halide Lamp Feature PAR Style. Open or Enclosed Luminaires. Lifetime Color Stability Within +/- 200K Watts 70 Bulb PAR-30L Base Med. Product Number 046677-23221-5 Ordering Code CDM70/PAR30L/M/FL Package Quantity 6 Description G, PAR WISO Flood 40 degrees FadeBlock 10,000 MBCP ANSI M143/M98/O Code/Ballast Ref. CRI 82 Rated Avg. Life 9000 (Hrs.) M.O.L. 4 3/4 Approximate 4850 Initial Lumens Approximate 3880 Mean Lumens CCT 3000 Images Literature Other Information + Family Photo + Family Brochure + Printable Page + Product Logo + MSDS S15-95004 + View Compatible Ballasts + Product Photo + MSDS S15-95005 + Photometric Data + Send this Link + Bookmark this Page † Heat resisting glass bulb + Technical Data Sheet Footnotes + ANSI CODE RATING, E - Enclosed, O - Open, S - Open or Enclosed + Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps. + Approximate lumen values listed are for vertical operation of the lamp. http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=28 4/3/2005 Protected MasterColor Ceramic Metal Halide Lamp 70 Watts Bulb PAR-30L Base Med. ... Page 2 of 2 + Click here for Recommended Warnings, Cautions and Operating Instructions. + Approximate lumen output at 40% of lamp rated average life. + Requires a ballast specified or approved for Philips Metal Halide lamp or one designed to the indicated ANSI Standard. A pulse ignitor is required. Sockets and wiring must withstand starting pulse. + Supply volts must be +/- 5% of rated ballast line volts for reactor type and +/- 10% for CWA or electronic ballasts. + UV filtered design (Fade-Block™). MasterColor® Metal Halide Lamps are not recommended for use on dimmers and are not warranted if used on dimmer systems. + + Excellent color rendition - up to 92 CRI + Heat resisting glass bulb + Click here for specific product and ordering information on this lamp. Information for this product last modified on June 22 2004. ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=28 4/3/2005 B3 Metal Halide Lamp Ballast Catalog Number 71A5282 For 70W M98/M143 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 3 X 4 CORE - 2 COIL UNIT 5.10 " 4.50" 0.7" 1.0" A B MAX. 0.25" WIDE 2 SLOTS 3.95" 3.50" 4 HOLES CLEARED FOR #10 THRU-BOLTS 2.45" 2.80" Capacitor: 7C080L33-R 2.90" INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±7% Lamp Watts LINE CURRENT (Amps) Operating................................................... 0.80 0.35 Open Circuit............................................... 1.90 0.80 Starting...................................................... 0.55 0.25 UL TEMPERATURE RATINGS Insulation Class H(180°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 255 INPUT VOLTAGE AT LAMP DROPOUT........................... 90 208 INPUT WATTS 88 RECOMMENDED FUSE (Amps)..................................... 4 2 CORE and COIL Dimension (A) 1.45 Dimension (B) 2.75 Weight (lbs.) 5 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads 8.0 Volts (min.) 280 Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 2000 2 seconds 2500 Open Circuit Voltage Test (Volts) 230-280 Short-Circuit Current Test (Amps) Secondary Current 0.95-1.25 Input Current.............................................. 0.55 0.25 0.80 0.45 - - - Wiring Diagram: LAMP CAP LINE V LINE V X3 X1 IGNITOR CAP LAMP LINE V X2 COM LINE V Capacitance: Dia/Oval Dim: Height: Temp Rating: 8 1.25 2.9 105°C COM COM Fig. K Ordering Information Ignitor: LI533-H4 Order Suffix 500D. 510D. 600. 610. Description Ballast With Ignitor and Dry Film Capacitor Ballast w/Welded Bracket, Ignitor, & Dry Film Capacitor Ballast and Ignitor, No Capacitor Ballast with Welded Bracket and Ignitor, No Capacitor Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 105°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 11/08/00 B4 18 MULTIPLE LARGE Designed for use in commercial spaces, like shops, restaurants,and displays, the multiple downlights are suitable in all projects where directional lighting is desired. Available in halogen, metal halide or a combination of both, the multiple is a versatile solution for applications where more than one lamp type is needed. This new serie of multi lamp downlights supports up to six independently directional units. Optical assemblies are adjustable in virtually all directions. This series are supplied with new construction plaster frame and integral electronic transformers and/or electronic ballasts, 120 volts (277-347 volts upon request). Relamping is simple and does not require tools. Directional recessed downlight provides direct light. Die cast aluminum optical assembly, steel frame, body and fastener. Uses PAR 30 and PAR 38 halogen, PAR 30, PAR 38 metal halide and AR111 low voltage. Available in grey. 19 MULTIPLE LARGE 1 x AR 111 75 W 8210-PAR 1 x PAR 30 75 W 8210-MH35 1 x Metal Halide PAR 30 35 W 8210-MH70 1 x Metal Halide PAR 30 70 W 8310-PAR 1 x PAR 38 90W 8310-MH 1 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 8210-AR 7-1/4" Multiple Large Single (MH) 8-7/8" Toronto University Architecture Dept. 6-1/2"x 6-1/2" 7-1/4" 2 x PAR 30 75 W 8220-1MH35 1 x AR 111 75 W+Metal Halide PAR 30 35 W 8220-1MH70 1 x AR 111 75 W+Metal Halide PAR 30 70 W 8220-2MH35 2 x Metal Halide PAR 30 35 W 8220-2MH70 2 x Metal Halide PAR 30 70 W 8320-PAR 2 x PAR 38 90W 8320-MH 2 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 2 x AR 111 75 W 8220-PAR 7-1/4 " 8220-AR (MH) 8-7/8" Multiple Large Double 6-1/2" x 12-5/8" 13-3/4" 8230-PAR 3 x PAR 30 75 W 8230-1MH35 2 x AR 111 75 W+Metal Halide PAR 30 35 W 8230-1MH70 2 x AR 111 75 W+Metal Halide PAR 30 70 W 8230-3MH35 3 x Metal Halide PAR 30 35 W 8230-3MH70 3 x Metal Halide PAR 30 70 W 8330-PAR 3 x PAR 38 90W 8330-MH 3 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 3 x AR 111 75 W 6-1/2" x 19" 7-1/4" 8230-AR (MH) 8-7/8" Multiple Large Triple 20-1/8" These are standard configurations. Custom configurations available upon request. 10 B4 18 MULTIPLE LARGE Designed for use in commercial spaces, like shops, restaurants,and displays, the multiple downlights are suitable in all projects where directional lighting is desired. Available in halogen, metal halide or a combination of both, the multiple is a versatile solution for applications where more than one lamp type is needed. This new serie of multi lamp downlights supports up to six independently directional units. Optical assemblies are adjustable in virtually all directions. This series are supplied with new construction plaster frame and integral electronic transformers and/or electronic ballasts, 120 volts (277-347 volts upon request). Relamping is simple and does not require tools. Directional recessed downlight provides direct light. Die cast aluminum optical assembly, steel frame, body and fastener. Uses PAR 30 and PAR 38 halogen, PAR 30, PAR 38 metal halide and AR111 low voltage. Available in grey. 19 MULTIPLE LARGE 1 x AR 111 75 W 8210-PAR 1 x PAR 30 75 W 8210-MH35 1 x Metal Halide PAR 30 35 W 8210-MH70 1 x Metal Halide PAR 30 70 W 8310-PAR 1 x PAR 38 90W 8310-MH 1 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 8210-AR 7-1/4" Multiple Large Single (MH) 8-7/8" Toronto University Architecture Dept. 6-1/2"x 6-1/2" 7-1/4" 2 x PAR 30 75 W 8220-1MH35 1 x AR 111 75 W+Metal Halide PAR 30 35 W 8220-1MH70 1 x AR 111 75 W+Metal Halide PAR 30 70 W 8220-2MH35 2 x Metal Halide PAR 30 35 W 8220-2MH70 2 x Metal Halide PAR 30 70 W 8320-PAR 2 x PAR 38 90W 8320-MH 2 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 2 x AR 111 75 W 8220-PAR 7-1/4 " 8220-AR (MH) 8-7/8" Multiple Large Double 6-1/2" x 12-5/8" 13-3/4" 8230-PAR 3 x PAR 30 75 W 8230-1MH35 2 x AR 111 75 W+Metal Halide PAR 30 35 W 8230-1MH70 2 x AR 111 75 W+Metal Halide PAR 30 70 W 8230-3MH35 3 x Metal Halide PAR 30 35 W 8230-3MH70 3 x Metal Halide PAR 30 70 W 8330-PAR 3 x PAR 38 90W 8330-MH 3 x Metal Halide PAR 38 70W (PAR/AR) 7-3/8" 3 x AR 111 75 W 6-1/2" x 19" 7-1/4" 8230-AR (MH) 8-7/8" Multiple Large Triple 20-1/8" These are standard configurations. Custom configurations available upon request. 10 B5 DELRAY 8" CYLINDER VERTICAL LAMP DOWNLIGHT 18" Clear Alzak® 14" NOTE: D1, D3, and EM Black Baffle Accessories add 4” to height Pendant mount Cylinder Splay with Fresnel Lens 8" SPECIFICATION INFORMATION CYLINDER HOUSING BALLAST Pendant mounted cylinder is constructed of seamless extruded aluminum with a powder coat finish. Standard height is 14” , dimming and emergency ballast add 4” to height. Fixture mounts to standard juction box. Pendant is 1/8 IPS steel and is standard in 18” (optional length can be specified) Electronic enclosed, class P, HPF is supplied standard in 120V or 277V. Ballasts use 4 pin lamps and provide rapid start, .99 power factor with THD<10%. Dimming ballast controls lumen output down to +- 5% and is available from Lutron D1 and D4 and Advance D3 . All require compatible dimmers. REFLECTOR ELECTRICAL Reflector is available in thirty degree cutoff .30 . Finishes are Clear A or Gold G Alzak for anodized, specular, durable and anti-iridescent reflectors. U.L. listed for use in damp locations. TRIM OPTIONS B black baffle G gold Alzak SP splay fesnel lens ACCESSORIES B black baffle BA ball aligner canopy D1 Lutron Hi-Lume dimming ballast adds 4” to length D3 Advance dimming ballast adds 4” to length D4 Lutron Tu-Wire dimming ballast 120V only EM emergency power pack ignites 1 lamp for 90 minutes adds 4” to length RC retro-fit for existing cylinder (consult factory) X custom pendant length (specify length) INCORPORATED CP8100 Gold Alzak® LIGHTING FINISHES BM brushed metal BZ bronze K black W white ORDERING INFORMATION LAMP 1-18 18 watt triple tube 1-26 26 watt triple tube 1-32 32 watt triple tube 1-42 42 watt triple tube 120V ELECT. CP8118.1E 18watt triple tube CP8126.1E 26watt triple tube CP8132.1E 32watt triple tube CP8142.1E 42watt triple tube 277V ELECT. CP8118.2E 18watt triple tube CP8126.2E 26watt triple tube CP8132.2E 32watt triple tube CP8142.2E 42watt triple tube 11916 VALERIO ST. NORTH FINISH MUST BE SPECIFIED HOLLYWOOD, CALIFORNIA 91605 SUBMITTAL INFORMATION TYPE: DESCRIPTION: PROJECT: PHONE NOTES: 818 982 3701 FAX 818 982 3715 CLEAR ALZAK 30° CP8118 CLEAR ALZAK 30° CP8126 14" CLEAR ALZAK 30° CP8132 14" CP8142 14" 8" CLEAR ALZAK 30° 14" 8" 8" 8" CONE OF LIGHT FC/0• MTG. HT. DIA. FC/0• MTG. HT. DIA. FC/0• MTG. HT. DIA. FC/0• MTG. HT. DIA. 4' 65 3.7 4' 81 3.7 4' 95 4.2 4' 123 4.3 6' 29 5.5 6' 39 5.5 6' 42 6.4 6' 54 6.6 8' 17 7.3 8' 19 7.3 8' 24 8.5 8' 31 8.8 10' 11 9.2 10' 12 9.2 10' 15 10.7 10' 19 10.9 12' 8 11.0 12' 9 11.0 12' 11 12.8 12' 14 12.9 50% FC at edge 50% FC at edge 50% FC at edge 50% FC at edge CP DISTRIBUTION 90° 90° 260 60° 400 310 60° 30° 90° 90° 200 60° 60° 400 520 620 800 600 780 930 1200 30° 800 30° 1040 1000 30° 1240 1300 1600 2000 1550 COEFFICIENTS OF UTILIZATION % CEILING 80 (20% FLOOR) % WALL 70 50 30 % CEILING 80 (20% FLOOR) % WALL 70 50 30 % CEILING 80 (20% FLOOR) % WALL 70 50 30 % CEILING 80 (20% FLOOR) % WALL 70 50 30 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 75 72 70 67 64 62 59 57 54 52 50 75 71 67 64 60 57 55 52 49 47 44 75 70 65 61 58 54 52 49 46 43 41 71 69 66 63 61 58 55 53 50 48 46 71 67 63 60 57 53 51 48 45 43 40 71 66 61 57 54 50 48 45 42 39 37 84 80 77 73 70 67 63 60 57 54 51 84 78 74 69 65 61 58 54 50 47 44 84 77 71 66 62 57 54 50 46 43 40 79 76 73 69 66 63 60 57 54 51 49 79 74 70 66 62 58 55 51 48 45 42 NOTES CP8118 CP8126 CP8132 CP8142 1-18 watt triple tube G24q-2 electronic socket Total lumens-1250 Spacing criteria-.9 Gold Alzak x.90 1-26 watt triple tube G24q-3 electronic socket Total lumens-1800 Spacing criteria-.9 Gold Alzak x.90 1-32 watt triple tube G24q-3 electronic socket Total lumens-2400 Spacing criteria-.9 Gold Alzak x.90 1-42 watt triple tube G24q-4 electronic socket Total lumens-3200 Spacing criteria-.9 Gold Alzak x.90 79 73 67 63 58 55 51 48 44 41 39 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 1 of 2 B5 PL-T Triple 4-Pin Fluorescent Lamp Feature High color rendering, high efficacy lamps feature 4-pin base for use with preheat, rapid start, electronic and dimming circuits. Featuring ALTO® Lamp Technology Watts 32 Bulb PL-T Base GX24q-3 Product 046677-26832-6 Number Ordering PL-T 32W/830/4P/ALTO Code Generic CFTR32W/GX24q/830 Designation Package 12 Quantity Description 3000K CRI 82 Avg. Hrs. 10,000 Life Design 2040 Lumens M.O.L. 5 5/8 Lumens 2400 Images Literature Other Information + ALTO Product Logo + ALTO Family Brochure • Energy Saving Product + Family Photo + MSDS S08-98001 + Printable Page + Product Photo + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + This Product Contains Amalgam + High Color Rendering Lamp Features ALTO® Lamp Technology + Rated average life under specified test conditions with Programmed Start ballasts with lamps + turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 2 of 2 + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. Information for this product last modified on September 25, 2001 ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 B5 IZT-2T42-M3-BS@120 Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status Electrical Specifications Lamp Type * CFM32W/GX24Q CFM42W/GX24Q CFTR57W/GX24Q CFTR70W/GX24Q Num. of Lamp s 2 2 1 1 Rated Lamp Watts Min. Start Temp (°F/C) 50/10 50/10 50/10 50/10 32 42 57 70 MARK VII 0-10V Electronic Dimming Programmed Start Series 120-277 50/60 HZ Active Input Current (Amps) Input Power (Watts) (min/max) Ballast Factor (min/max) MAX THD % Power Factor Lamp Current Crest Factor B.E.F. 0.63 0.82 0.55 0.67 19/75 18/98 18/66 18/80 0.05/1.00 0.05/1.00 0.05/1.00 0.05/1.00 10 10 10 10 0.99 0.99 0.99 0.99 1.4 1.4 1.7 1.7 1.33 1.02 1.52 1.25 Wiring Diagram Enclosure WIRING: (2) TRIPLE LAMPS LINE CLASS 1&2 CIRCUIT 10V, 0.5mA BLACK WHITE VIOLET (+) GREY (-) GREEN BLUE BALLAST Y E L L O W RED Green Terminal must be Grounded The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Enclosure Dimensions Standard Lead Length (inches) Black White Blue Red Yellow Gray Violet in. 0 0 0 0 0 0 0 cm. 0 0 0 0 0 0 0 in. Yellow/Blue Blue/White Brown Orange Orange/Black Black/White Red/White cm. 0 0 0 0 0 0 0 OverAll (L) 6.28 " 6 7/25 16 cm Width (W) 3.00 " 3 7.6 cm Height (H) Mounting (M) 1.29 " 2.00 " 1 29/100 2 3.3 cm 5.1 cm Revised 08/27/2003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 IZT-2T42-M3-BS@120 Electrical Specifications Notes: Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status MARK VII 0-10V Electronic Dimming Programmed Start Series 120-277 50/60 HZ Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements. 1.3 Ballast shall be provided with poke-in wire trap connectors or integral leads color coded per ANSI C82.11. Section II - Performance Requirements 2.1 Ballast shall be Programmed Start. 2.2 Ballast shall be provided with integral protection circuitry to withstand connection of low voltage control leads to mains power supply. In this event, ballast shall default to maximum light output. 2.3 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.4 Ballast shall operate from 50/60 Hz input source of 120V or 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. IntelliVolt models shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. 2.5 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker. 2.6 Ballast shall have a Power Factor greater than 0.98 at full light output and greater than 0.90 throughout the dimming range for primary lamp. 2.7 Ballast shall have a maximum ballast factor of 1.00 (1.18 for HL versions) at maximum light output and 0.03 at minimum light output for primary lamp application. 2.8 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less throughout the dimming range in accordance with lamp manufacturer recommendations. 2.9 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.10 Ballast shall have a Class A sound rating. 2.11 Ballast shall have a minimum starting temperature of 10C (50F) for primary lamp. 2.12 Ballast shall provide Lamp EOL Protection Circuit for all T5, T5/HO, CFL lamps, and T8 lamps operating on 4-lamp ballast. 2.13 Ballast shall control lamp light output from 100% - 3% relative light output for T8 and CFL lamps and 100% - 1% relative light output for T5/HO lamps. 2.14 Ballast shall ignite the lamps at any light output setting without first going to another output setting. 2.15 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. Section III - Regulatory Requirements 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 Ballast shall comply with ANSI C82.11 where applicable. 3.5 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated). Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 70C. 4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. 4.4 Ballast shall be controlled by a Class 1 or Class 2 low voltage 0-10VDC controller. 4.5 Ballast shall be Advance Transformer part # _____________ or approved equal. Revised 08/27/2003 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD ROSEMONT, ILLINOIS 60018 TELEPHONE: (847) 390-5000 FAX: (847) 390-5109 B6 9" x 9" Floating Paper Optic Forms Spectral Architectural Lighting 04-05 SL207C 2-26/32/42W Triple Twin Tube Ceiling Cutout : 9 5/8" (245mm) X 9 5/8" (245mm) Ordering Guide (complete unit only) Cat. No. SL207CTEU SL207CTE3 Lamp (Triple Twin Tube) 2-26/32/42W TTT Volts Finish 120/277V 347V SL207CPPU 2-26W TTT 120/277V (HDF) SL207CPOU 2-32/42W TTT 120/277V (HDF) Clear acrylic with white lacquer lens and brushed stainless steel square trim. 120V (MARK-10) Stainless steel screws . SL207CTZ1 SL207CTZ2 SL207CTR1 SL207CTR2 2-26W TTT 2-32/42W TTT 277V (MARK-10) 120V (MARK-10) 277V (MARK-10) Features 1. Lens : 40mm thick clear acrylic finished with a translucent diffused coating. 2. Trim Ring : 18 ga. Steel. Brushed Stainless finish. 3. Upper Reflector: High efficiency, 97%, Specular Clear. 4. Housing: 20ga. Galvanized formed steel. Centerline notches and holes for consistent alignment of multiple fixtures. Accommodates ceilings up to 1 1/4" (31mm) thick. 5. Ballast Assembly: Door-mounted for easy service, allows replacement from inside of fixture. 6. Junction Box: 14 ga. Galvanized steel. Accessible from inside and outside of the fixture. Outside J-box door is hinged for easy access. 7. Mounting Brackets: 16 ga. steel. Use 18" (457 mm) mounting bars (optional) or with standard 3/4" (19 mm), 1-1/2" (38 mm) lathing channels (by others) or 1/2” (13 mm) tubing (by others). Adjust vertically from inside of fixture. 8. Junction Box: CSA certified for through branch circuit wiring with maximum of 8 no. 12, 90º C conductors. Electrical Ballast : Electronic Program Rapid Start T4 quad lamp ballast. Universal voltage "U" ballast automatically detect 120 volts or 277 volts operation. No visible flicker on starting, internally fused and protection circuit for lamp end of life. Sound rated “A”. Designed for removal without tools from inside of luminaire for easy field inspection or service replacement. TE : 26/32/42W TTT non-dimming PP : 26W TTT HDF dimming PO : 32/42W TTT HDF dimming TZ : 26W TTT MARK-10 dimming TR : 32/42W TTT MARK-10 dimming Lampholder : 26/32W : G24q-3 base, 42W : G24q-4 (4-pins) Options and Accessories Mounting bars: 1950 (set of 2) 18" (457 mm) long. 1951 (set of 2) 30" (762 mm) long. T-Bar Anchor Clips : 1956 (set of 4) For anchoring mounting bars to T-Bar runners. Mounting Recessed, Non-IC Type (non thermal insulation contact). Finish Lens : Clear acrylic with white lacquer Square Trim : Brushed Stainless steel Labels UL "c/us" Listed. Suitable for wet locations. WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH, IN ANY WAY THAT WILL NOT ALTER INSTALLED APPEARANCE OR REDUCE FUNCTION AND PERFORMANCE. Lightolier Canada, 3015 Louis Amos Lachine, (Quebec) H8T 1C4 04-05 Floating Paper 9" x 9" Optic Forms 2-26/32/42W Triple Twin Tube Spectral Architectural Lighting SL207C PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 1 of 2 B6 PL-T Triple 4-Pin Fluorescent Lamp Feature High color rendering, high efficacy lamps feature 4-pin base for use with preheat, rapid start, electronic and dimming circuits. Featuring ALTO® Lamp Technology Watts 32 Bulb PL-T Base GX24q-3 Product 046677-26832-6 Number Ordering PL-T 32W/830/4P/ALTO Code Generic CFTR32W/GX24q/830 Designation Package 12 Quantity Description 3000K CRI 82 Avg. Hrs. 10,000 Life Design 2040 Lumens M.O.L. 5 5/8 Lumens 2400 Images Literature Other Information + ALTO Product Logo + ALTO Family Brochure • Energy Saving Product + Family Photo + MSDS S08-98001 + Printable Page + Product Photo + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + This Product Contains Amalgam + High Color Rendering Lamp Features ALTO® Lamp Technology + Rated average life under specified test conditions with Programmed Start ballasts with lamps + turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 2 of 2 + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. Information for this product last modified on September 25, 2001 ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 B6 ICF-2S42-M2-BS@120 Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status Electrical Specifications Lamp Type (1) FC9T5 & (1) FC12T5 CFM26W/GX24Q * CFM32W/GX24q CFM42W/GX24q CFM57W/GX24Q CFM70W/GX24Q CFQ26W/G24q CFS28W/GR10q CFS38W/GR10q FT24W/2G11 FT40W/2G11/RS Num. of Lamp s 2 Rated Lamp Watts Min. Start Temp (°F/C) Input Current (Amps) 62 0/-18 2 2 2 1 1 2 2 2 2 2 26 32 42 57 70 26 28 38 24 40 0/-18 0/-18 0/-18 32/00 14/-10 0/-18 0/-18 0/-18 0/-18 0/-18 Wiring Diagram BLUE BLACK WHITE Ballast Factor MAX THD % Power Factor MAX Lamp Current Crest Factor B.E.F. 0.51 Input Power (ANSI Watts) 61 0.85 10 0.98 1.5 1.39 0.46 0.57 0.78 0.50 0.63 0.43 0.48 0.55 0.40 0.66 55 68 93 59 75 52 57 62 48 78 1.00 0.98 0.97 0.94 0.96 1.00 1.00 0.80 0.93 0.95 10 10 10 10 10 10 10 10 15 10 0.98 0.98 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 1.5 1.5 1.5 1.5 1.6 1.5 1.5 1.5 1.5 1.5 1.82 1.44 1.04 1.59 1.28 1.92 1.75 1.29 1.94 1.22 Enclosure WIRING: (2) LAMPS LINE SMARTMATE Electronic Programmed Start Series 120-277 50/60 HZ Active (1) LAMP BLUE BALLAST Y E L L O W GREEN RED RED Green Terminal must be Grounded The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Enclosure Dimensions Standard Lead Length (inches) Black White Blue Red Yellow Gray Violet in. 0.0 0.0 0.0 0.0 0 cm. in. Yellow/Blue Blue/White Brown Orange Orange/Black Black/White Red/White cm. OverAll (L) 4.98 " 4 49/50 12.6 cm Width (W) 3.00 " 3 7.6 cm Height (H) Mounting (M) 1.29 " 2.00 " 1 29/100 2 3.3 cm 5.1 cm Revised 09/02/2004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 ICF-2S42-M2-BS@120 Electrical Specifications Notes: Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status SMARTMATE Electronic Programmed Start Series 120-277 50/60 HZ Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements. 1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11. Section II - Performance Requirements 2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start. 2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. 2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker. 2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp. 2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application. 2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations. 2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.9 Ballast shall have a Class A sound rating. 2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting temperature of -30C (-20F) for primary lamp. 2.11 Ballast shall provide Lamp EOL Protection Circuit which meets NEMA recommendations. 2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. Section III - Regulatory Requirements 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces. 3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.5 Ballast shall comply with ANSI C82.11 where applicable. 3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B). Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120XX-XX, ICF2S70-XX-XX and ICF2S4290C-XX-XX modesls). 4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. 4.4 Ballast shall be Advance Transformer part # _____________ or approved equal. Revised 09/02/2004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD ROSEMONT, ILLINOIS 60018 TELEPHONE: (847) 390-5000 FAX: (847) 390-5109 B7 FEATURES OPTICAL SYSTEM • Internal housing components painted matte black. Lamp snoot minimizes stray light in housing. • Finishing trim is microgroove black baffle with white painted flange or specular, semi-diffuse or highly specular cone with flange that matches cone finish. White painted flange optional. • Optical system retained by self-aligning butterfly support springs. • Accommodates up to two lenses, filters or louvers. • Softening lens standard (supplied). MECHANICAL SYSTEM • Black painted housing features tool-less top access and accommodates a maximum 2" ceiling thickness. • Re-lamp capability from above or below ceiling. • Mounting bars are 16-gauge galvanized steel with continuous 4" vertical adjustment, held in place with tool-less, integral cam-action locking. Post installation adjustment possible without the use of tools from above or below the ceiling. Shipped pre-installed. • Secondary housing adjustment system for precise, final flange to ceiling alignment. • Painted steel junction box with bottom-hinged access covers and spring latches. Four combination 1/2"-3/4" knockouts for straight-through conduit runs. Capacity: 8(4 in, 4 out) No. 12 AWG conductors, rated for 90°C. ELECTRICAL SYSTEM • Tool-less access door provides access to junction box through the aperture. • Replaceable socket assembly. MR16 socket assembly standard (20W - 75W). • Magnetic step-down transformer (replaceable without the use of tools). • Thermally-activated insulation detector (replaceable without the use of tools). LISTING • Fixtures are UL listed for thru-branch wiring, recessed mounting and damp locations. Listed and labeled to comply with Canadian Standards. Type Catalog number ......................... ................................................................................ ......................... ................................................................................ Low Voltage Downlights 4" DLV Downlight Open Cone 6-3/4 (17.1) Aperture: Ceiling opening: Overlap trim: 4-5/16 (11.0) 4-7/8 (12.4) 5-7/16 (13.8) All dimensions are inches (centimeters). 13-3/4 (34.9) 16-1/8 (41.0) Example: ORDERING INFORMATION DLV DWN MR16 4AC 120 Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog numbers (shipped separately). DLV DWN Series DLV Lamp designation MR16 MR11 Configuration DWN ALR12 ALR18 AR70 1 MR16 capability (Standard) MR11 capability ALR12 capability ALR18 capability AR70 capability Cone/Color 2 4BC 4AC 4PC 4WTC 4UBC 4GC 4CC 2 4WC 2 4MB NOTES 1 Clear safety lens standard with AR70 lamp designation. 2 Not available with finishes. 3 For compatible Reloc systems, refer to options and accessories tab. 2 4WB Black Clear Pewter Wheat Umber Gold Champagne gold White Contoured black baffle Contoured white baffle Finish (blank) LD LS Specular low iridescent Semidiffuse low iridescent Highly specular Volt 120 Options TRW 277 347 LRC 3 White painted flange. (Standard with WC, MB, and WB.) Provides compatibility with Lithonia Reloc System. Accessories • For lens accessories, refer to options and accessories tab. • For lamp options, refer to options and accessories tab. DLV 4 DLV-140 4" DLV Downlight, Gotham Series Distribution curve Distribution data DLV DWN MR16 4AC, 90° 1200 2400 3600 4800 6000 0° 0° 5° 15° 25° 35° 45° 45° 55° 65° 75° 85° 90° 90° 1600 3200 4800 6400 8000 0° 90° 400 800 1200 1600 2000 0° 90° 600 1200 1800 2400 3000 0° From 0° cp. 5263 3805 936 114 12 3 4 8 5 3 0 Lumens 301 262 58 8 2 5 6 5 5 Zone Lumens %lamp 0°-30° 0°-40° 0°-60° 0°-90° 90°-180° 0°-180° 622 630 637 654 0 654 70.7 71.6 72.4 74.3 0.0 74.3* * Efficiency rf 20% rc 80% 70% 50% rw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 84 80 77 74 72 70 68 66 65 63 82 78 74 71 69 67 65 63 62 61 82 79 76 73 71 69 67 66 64 63 81 77 73 71 68 66 65 63 62 60 79 76 74 72 70 68 67 65 64 63 78 75 72 70 68 66 64 63 61 60 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 174.0 93.6 58.3 39.8 28.9 50% 10% beam angle 15.6° beam angle 35.1° fc at fc at Beam beam Beam beam diameter edge diameter edge 1.5' 2.1' 2.6' 3.2' 3.7' 87.0 46.8 29.2 19.9 14.4 3.5' 17.4 4.8' 9.4 6.0' 5.8 7.3' 4.0 8.6' 2.9 cp. 7027 5017 1182 126 15 0 0 0 0 0 0 Lumens 398 334 74 11 0 0 0 0 0 Zone Lumens %lamp 0°-30° 0°-40° 0°-60° 0°-90° 90°-180° 0°-180° 806 817 817 817 0 817 73.2 74.2 74.2 74.2 0.0 74.2* * Efficiency rf 20% rc 80% 70% 50% rw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 84 81 78 76 73 72 70 68 67 65 83 79 76 73 71 69 67 66 64 63 83 80 77 75 73 71 69 68 66 65 82 78 75 73 70 69 67 65 64 63 80 77 75 73 72 70 69 67 66 65 79 76 74 72 70 68 66 65 64 62 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 232.3 124.9 77.9 53.1 38.6 50% 10% beam angle 15.3° beam angle 34.2° fc at fc at Beam beam Beam beam diameter edge diameter edge 1.5' 116.1 2.0' 62.5 2.6' 38.9 3.1' 26.6 3.6' 19.3 3.4' 23.2 4.6' 12.5 5.8' 7.8 7.1' 5.3 8.3' 3.9 , 50MR16Q/40/FL (EXN) lamp, 0.5 s/mh, 880 rated lumens, test no. 2198040605 From 0° 0° 5° 15° 25° 35° 45° 45° 55° 65° 75° 85° 90° DLV DWN MR16 4AC Single luminaire data 30" above floor 65MR16Q/10/NSP (FPA) lamp, 0.3 s/mh, 1100 rated lumens, test no. 2198040602 0° 5° 15° 25° 35° 45° 45° 55° 65° 75° 85° 90° DLV DWN MR16 4AC Coefficient of utilization Q50MR16/C/NSP15 (EXT) lamp, 0.3 s/mh, 880 rated lumens, test no. 2198043004 From 0° DLV DWN MR16 4AC, Output data cp. 1773 1646 962 291 43 1 0 0 0 0 0 Lumens 147 262 139 29 1 0 0 0 0 Zone Lumens %lamp 0°-30° 0°-40° 0°-60° 0°-90° 90°-180° 0°-180° 548 577 578 578 0 578 62.3 65.6 65.7 65.7 0.0 65.7* * Efficiency rf 20% rc 80% 70% 50% rw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 74 70 67 64 61 59 57 54 53 51 73 68 64 61 58 56 54 52 50 48 73 69 66 63 61 58 56 54 52 51 71 67 64 61 58 56 53 51 49 48 70 67 64 62 60 57 55 54 52 50 69 65 62 60 57 55 53 51 49 48 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 58.6 31.5 19.6 13.4 9.7 50% 10% beam angle 29.5° beam angle 52.1° fc at fc at Beam beam Beam beam diameter edge diameter edge 2.9' 29.3 4.0' 15.8 5.0' 9.8 6.1' 6.7 7.1' 4.9 5.4' 7.3' 9.3' 11.2' 13.2' 5.9 3.2 2.0 1.3 1.0 , Q71MR16/C/FL40 (EYC) lamp, 0.5 s/mh, 1100 rated lumens, test no. 2198043005 From 0° 0° 5° 15° 25° 35° 45° 45° 55° 65° 75° 85° 90° cp. Lumens 2280 2027 1190 405 62 0 1 1 1 1 0 182 325 189 42 1 1 1 1 1 Zone Lumens %lamp 0°-30° 0°-40° 0°-60° 0°-90° 90°-180° 0°-180° 696 738 741 744 0 744 63.3 67.1 67.3 67.6 0.0 67.6* * Efficiency NOTES 1 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications are based on the most current available data and are subject to change without notice. DLV-140 ©2003 Gotham, Rev. 01/03 DLV-140.P65 rf 20% rc 80% 70% 50% rw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 76 72 68 65 63 60 58 55 53 52 75 70 66 62 59 57 54 52 50 48 74 71 68 65 62 59 57 55 53 51 73 69 65 62 59 57 54 52 50 48 72 69 66 63 61 59 56 54 53 51 71 67 64 61 58 56 54 52 50 48 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 75.4 40.5 25.3 17.2 12.5 50% 10% beam angle 28.6° beam angle 52.9° fc at fc at Beam beam Beam beam diameter edge diameter edge 2.8' 37.7 3.8' 20.3 4.8' 12.6 5.9' 8.6 6.9' 6.3 5.5' 7.5' 9.5' 11.4' 13.4' 7.5 4.1 2.5 1.7 1.3 Long Life ESX 20W GU5.3 12V MR16 10D CL 1CT Page 1 of 3 B7,B8 Long Life ESX 20W GU5.3 12V MR16 10D CL 1CT | Save PDF | Open PDF General PRODUCT DATA Product Number 378141 Full product name Long Life ESX 20W GU5.3 12V MR16 10D CL 1CT Ordering Code 20MRC16/SP10 Pack type 1 Lamp in a Folding Carton Pieces per pack 1 Packs per case 50 Pack UPC 046677378141 EAN2US - Case Bar Code 50046677378146 Successor Product number - ANSI Code Halogen ESX Wattage[W ] 20W Base GU5.3 [GU5.3] Voltage[V ] 12V Bulb MR16 [MR 16inch/50mm] Beam Angle[D ] 10D Bulb Finish CL [Clear] Packing Type 1CT [1 Lamp in a Folding Carton] Operating Position Universal[Universal] Packing Configuration 10X5F Rated Avg. Life[hr ] - Dimmable Yes Approx. MBCP[cd ] - Color Rendering Index[Ra8 ] 100 Color Temperature[K ] 3000 Overall Length C[mm ] 46 Diameter D[mm ] 50 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 Long Life ESX 20W GU5.3 12V MR16 10D CL 1CT Page 2 of 3 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 Long Life ESX 20W GU5.3 12V MR16 10D CL 1CT Page 3 of 3 Dimensions PRODUCT DIMENSIONS Characteristic Value Overall Length C (DTB) 46 mm Diameter D (DTB) 50 mm ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 D1 FIXTURE D1 CUSTOM D1 D2 JOB: __________________________ LOCATION: ____________________ CATALOG: DECORATIVE D4 2003/04 DATE: _________________________ PRODUCT SPECIFICATIONS STYLE # D4-1027 SERIES NAME: ICE STRUCTURE: Metal COLOR /FINISH: Aluminum Custom Bronze Finish 43” / 112 cm DIFFUSER: Clear and Frost Glass LAMP TYPE: Halogen G9 Frost MAX WATT: 1 x 40W ADA DIMENSIONS: W. 4 ½” x Ht. 43” x Ext. 4 ½” 4 ½” / 11 cm APPROVALS: Approved by CSA for North American Standards. NOTES: _________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ ZANEEN LIGHTING 65 DENSLEY AVE. TORONTO, ONTARIO, CANADA M6M 2P5 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com zaneen@zaneen.com D2 O1 Job Name: CALLISTO-12 Fixture Type: Job Number: Distributor: Distributor P.O. : 1. H O U S I N G CL12 Housing: two-piece die-cast aluminum with internal component mounting bosses. 10.39" 3.45" 14.30" 13.38" 12" Door frame: one-piece die-cast aluminum secured with three phillips head screws. 9.81" Lens assembly: various clear or prismatic glass lens (beam dependant) gasketed to door to ensure a tight seal. 9.62" 0.18" EPA (fixture only): 0.62 2" FIXTURE WEIGHT: 28 LBS. The luminaire shall be cULus listed for wet locations and manufactured from UL-recognized components. (shown with optional eggcrate shield) 2. L A M P W A T T A G E METAL HALIDE (H.I.D.) ED17 HIGH PRESSURE SODIUM (H.I.D.) ED17 70 WATT METAL HALIDE (70MH) 100 WATT HIGH PRESSURE SODIUM (100HPS) 100 WATT METAL HALIDE (100MH) 150 WATT HIGH PRESSURE SODIUM (150HPS) 150 WATT METAL HALIDE (150MH) 175 WATT METAL HALIDE (175MH) Quartz WATTAGE PAR56 (500QTZ) 500 WATT QUARTZ HALOGEN (Electronic ballast available only in 70MH or 100MH) 3. B E A M P A T T E R N METAL HALIDE & HIGH PRESSURE SODIUM INCANDESCENT NARROW SPOT SPOT (SP) RECTANGULAR NARROW (RN) RECTANGULAR MEDIUM (RM) (NSP) RECTANGULAR WIDE (RW) MEDIUM FLOOD RECTANGULAR NARROW VERTICAL (RNV) Item Number: ORDER NUMBER: 1 RECTANGULAR MEDIUM VERTICAL (RMV) 2 3 RECTANGULAR WIDE VERTICAL (RWV) 4 5 FLOOD 6 (WFL) 7 8 9 10 MOUNTING OPTION SHIELD OPTION FINISH GENERAL OPTION YK CL12 HOUSING WIDE (MFL) LAMP WATTAGE BEAM PATTERN VOLTAGE BALLAST (FOR HID) MODEL STYLE 4. V O L T A G E 5. B A L L A S T (H.I.D. ONLY) 120 277 CORE & COIL 208 347 ELECTRONIC 240 480 6. M O D E L (C) YOKE (YK) (EB) (Ballast is an integral part of the fixture housing.) (Electronic ballast available only in 70WMH and 100WMH, and in 120 or 277 volt. Rated for -20 F (-28.9 C).) (Electronic ballast available only in 120 or 277 volts.) (Quartz available in 120 volt only.) (Core and coil ballast is high-power factor and rated for -20 F (-28.9 C).) 7. M O U N T I N G O P T I O N S BASE PLATE (BP) 0.56" (4) 6.00" DIA. BOLTCIRCLE WALL BRACKET (WB) 1.81" 1.16" 3/ 8" LOCKING BOLT CANBE MOUNTED TO2" PIPE (MAX) WITH 5/ 8" PIVOT U-BOLTS (U-BOLTS BOLT BY OTHERS) 3/ 4" MOUNTING HARDWARE 6.00" 3/ 4" MOUNTING HARDWARE 1.38" BASE PAD (PD) 2.06" I.D. 6.00" 2.38" O.D. SLIP FITTER 3.44" 3.13" 3.50" CASTDUCTILE IRON WALLBRACKETAND HORIZONTALSECTOR 6.25" 0.56" (4) 3.50" 4.50" .25" ALLCOMPONENTS STEEL. WELDCONSTRUCTION 8. O P T I O N A L S H I E L D S (SF) TOFIT2" (2.38" O.D.) PIPE TENONX 4.00" LONG (MIN.) REMOVABLE PIPE PLUGFOR 3/ 4" MOUNTING INSTALLING HARDWARE WATER-TITE CONNECTOR (SUPPLIED) 5.63" WATER-TITE CONNECTOR REMOVABLE SPLICE INSPECTION COVER CASTTENZALLOY FITTER REMOVABLE HOLE PLUGFOR 1/ 2" SET SIDE YOKE SCREWS MOUNTING EGGCRATE (EC) VER. LOUVER (VL) 6.17" HOR. LOUVER 7.90" 6.17" 6.17" 2.46" 7.90" 3.0" TOP SHIELD (TS) 6.17" 4.0" CUSTOM SHIELD (HL) 6.17"" 3.0" 6.17" (CS) The eggcrate is the only shield finished to match luminaire. Standard shield finish is black unless otherwise specified. 6.17" 9. F I N I S H 10. G E N E R A L O P T I O N S (BK) DARK BRONZE (BZ) WHITE (WH) NATURAL ALUMINUM (AL) NON-STANDARD (NS) INCLUDE LAMP BLACK (2" SCH. 40 STEELPIPE) (for use with SF option) 8.00" 5.50" .38" CASTDUCTILE IRON SURFACE BASE 6.00" DIA. BOLTCIRCLE 1.50" 1.50" 0.56" (4) (LP) SAFETY CABLE (SC) FUSE LUMINAIRE (FL) (SELECT 'LP' ONLY IF A LAMP IS TO BE INCLUDED) 70MH ED17 100HPS ED17 100MH ED17 150HPS ED17 150MH ED17 175MH ED17 500QTZ PAR56 REMARKS: S t e r n e r L i g h t i n g S y s t e m s I n c o r p o r at e d 351 LEWIS AVENUE WEST, P.O. BOX 805 WINSTED, MN 55395-0805 T E L 3 2 0 . 4 8 5 . 2 1 4 1 FA X 3 2 0 . 4 8 5 . 2 8 8 1 T O L L - F R E E 8 0 0 . 3 2 8 . 7 4 8 0 2/2002 w w w. s t e r n e r l i g h t i n g . c o m MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Page 1 of 3 O1 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB | Save PDF | Open PDF General PRODUCT DATA Product Number 233684 Full product name MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Ordering Code MHC100/U/MP/3K ALTO Pack type 1 Sleeve Open End Pieces per pack 1 Packs per case 12 Pack UPC 046677233686 EAN2US - Case Bar Code 50046677233681 Successor Product number - Wattage[W ] 100W Color Code 830 [CCT of 3000K] Base Med [Medium] Bulb ED17P [Diameter: 2.125 inch Protected] Bulb Finish CL [Clear] Feature ALTO+FB [ALTO® + FadeBlock™] Base Information Brass[Brass Base] Bulb Material Hard Glass Execution Protected Operating Position Universal[Universal] Packing Type 1SL[1 Sleeve Open End] Packing Configuration 12 Rated Avg. Life[hr ] 16000 Mercury Weight[mg ] 7.2 ANSI Code HID M140/M90/O Lamp Voltage[V ] 101 Color Rendering Index[Ra8 ] 85 Color Designation Warm White Color Temperature[K ] 3000 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Initial Lumens[Lm ] Page 2 of 3 8600 Design Mean Lumens[Lm ] 6450 Light Center Length L [inch][in ] 3.438 Max Overall Length (MOL) - C[in ] 5.438 Diameter D[in ] 2.125 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Page 3 of 3 Dimensions ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 O1 Metal Halide Lamp Ballast Catalog Number 72C5381 For 100W M90/M140 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 10.50" CASE "F-1" 2.63" 11.13" 3.19" 11.75" Capacitor: INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±12% Lamp Watts LINE CURRENT (Amps) Operating................................................... 1.10 0.48 Open Circuit............................................... 2.55 1.10 Starting...................................................... 2.20 0.95 UL TEMPERATURE RATINGS Insulation Class A (105°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 277 INPUT VOLTAGE AT LAMP DROPOUT........................... 72 166 INPUT WATTS 125 RECOMMENDED FUSE (Amps)..................................... 6 3 CORE and COIL Dimension (A) Dimension (B) Weight (lbs.) 11 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads Volts (min.) Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 1600 2 seconds 2000 Open Circuit Voltage Test (Volts) 250-305 Short-Circuit Current Test (Amps) Secondary Current 1.30-1.60 Input Current.............................................. 0.70 0.30 1.10 0.50 - - - Wiring Diagram: All Lead Lengths 12" 277 V The capacitor is included as part of the potted assembly. 120V COMMON YELLOW/BLUE BLACK BALLAST WHITE RED LAMP GROUND CASE F-Can Wiring Diagram Ordering Information Ignitor: IN CAN Order Suffix Description The ignitor is included as part of the potted assembly. Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 90°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 09/03/99 O2 Lichtpunkt mit 9 LED aus Edelstahl, mit klarem Abdeckglas zur punktuellen Beleuchtung oder in opaler Optik mit homogener Leuchtdichte. Light spot with 9 LED in stainless steel, with clear glass cover for point illumination or in opal optic with homogenous luminance. Spot lumineux avec 9 LED en acier inoxidable, avec verre de protection transparent pour un éclairage ponctuel, ou verre de couleur opale pour une luminosité homogène. 03 03 03 03 03 LBS LBS LBS LBS LBS 4201 4211 4221 4231 4241 rot/red/rouge gelb/yellow/jaune grün/green/vert blau/blue/bleu weiß/white/blanc ø 48 min. 40 LEDdot ø 40 Sonderfarben auf Anfrage. Special colours on request. Couleurs spéciaux sur demande. NV LED LED dot 24 V DC 1,2 W 0,1 kg 144 IP65 F Anschluß mit 2-poligem Kabel. Begeh- und überrollbar, jedoch nicht für Verkehrswege zugelassen. Connection via 2-pole cable. Driveover proof but not approved for traffic ways. Connexion par câble 2-pôle. Resistant à la charge à court terme. 230/240 V 15 LE 0026 24 V/20 W/IP 20 15 LE 0059 24 V/75 W/IP 20 15 LE 9120 24 V/120 W/IP 20 Farbcodierung und technische Hinweise siehe Anhang/Colour code and technical informations see appendix/Code de couleur et informations techniques voir notes annexe Technische Änderungen vorbehalten! Subject to technical alterations! Sous réserve de modification technique! ©Ansorg GmbH ® Lumière DESCRIPTION S P E C I F I C AT I O N F E AT U R E S Coronado 806 is a ultra-compact line voltage fixture for use with PAR20 halogen lamps. The fully adjustable mounting stem provides 340° tilt and 360° rotation for easy aiming. Various lenses, louvers and color or dichroic filters can be combined – up to three at once – to create multiple lighting effects. Lumière’s exclusive Siphon Protection System (S.P.S.) prevents water from siphoning into the fixture through its own lead wires. M AT E R I A L Catalog # Hood and mounting stem are precision-machined from corrosion-resistant 6061-T6 aluminum billet. Housing is die-cast aluminum. Type O3 Project Comments Prepared by FINISH Fixtures are double protected by a chromate conversion undercoating and polyester powdercoat paint finish, surpassing the rigorous demands of the outdoor environment. A variety of standard colors are available. HOOD Hood is removable for easy relamping and accepts up to three internal accessories at once (lenses, louvers, filters) to achieve multiple lighting effects. Weep holes prevent water and mineral stains from collecting on the lens, even in the straight-up position. GASKET Housing and hood are sealed with a high temperature silicone o-ring gasket to prevent water intrusion. LENS Tempered glass lens, factory sealed with high temperature adhesive to prevent water intrusion and breakage due to Date thermal shock. MOUNTING STEM Adjustable side-mounted swivel stem provides 340° tilt and 360° rotation for easy aiming. Equipped with standard 1/2" NPS threaded male fitting. Stainless steel aim-locking mechanisms are standard. Lumière’s exclusive Siphon Protection System (S.P.S.) prevents water from siphoning into the fixture through its own lead wires. HARDWARE Stainless steel hardware is standard to provide maximum corrosion-resistance. SOCKET Ceramic socket with 200° C Teflon® coated lead wires and medium base. CORONADO 806 5 0 W (max.) P A R 2 0 Halogen L I N E V O LT A G E ELECTRICAL Operates with 120V line voltage. ACCENT/FLOOD LAMP Not included. Available from Lumière as an accessory – see Lamps under Optical Accessories on the reverse side of this page. ø2-3/4" [70mm] 6-3/8" [162mm] L A B E L S & A P P R O VA L S UL and cUL listed, standard wet label. Manufactured to ISO 9001-2000 Quality Systems Standard. IBEW union made. WARRANTY Lumière warrants its fixtures against defects in materials & workmanship for three (3) years. Auxiliary equipment such as transformers, ballasts and lamps carry the original manufacturer’s warranty. 1-3/4" [44mm] Coronado 806 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : 8 0 6 - 5 0 PA R 2 0 - 1 2 0 - B K Model Source Vo l t s 806 50PAR20 120 806 Halogen 50PAR20 = 50W/PAR20/medium Lamp not included WWW.COOPERLIGHTING.COM 120 = 120V Finish Accessories (Order Separately) Painted BK = Black BZ = Bronze CS = City silver VE = Verde WT= White Consult your representative for additional options and finishes. See reverse page ADL032489 CORONADO 806 P H O T O M E T R I C D ATA Coronado 806 Lamp=50PAR20/NSP CBCP=5000 Cone of Light Distance to Illuminated Plane Initial Nadir Footcandles 25'0" 20'0" 15'0" 12'0" 10'0" 8'0" Coronado 806 Lamp=50PAR20/NFL CBCP=1400 Beam Diameter 10'0" 8'0" 6'0" 5'0" 4'0" 3'0" 8 13 23 35 50 80 Cone of Light Distance to Illuminated Plane Initial Nadir Footcandles 25'0" 20'0" 15'0" 12'0" 10'0" 8'0" Beam Diameter 20'0" 16'0" 12'0" 9'6" 8'0" 6'6" 2 3 6 9 13 20 L A M P I N F O R M AT I O N Lamp 50PAR20/NSP 50PAR20/NFL ANSI Code ----- Watts 50 50 Beam Spread 10° 30° CBCP 5000 1400 °K ----- Life (hrs.) 2000 2000 Base medium medium Volts 120 120 NOTE: Inferior quality lamps may adversely affect the performance of this product. Use only name brand lamps from reputable lamp manufacturers. OPTICAL ACCESSORIES Color & Dichroic Filters F22-20 = Red color F33-20 = Blue color F44-20 = Green color F55-20 = Yellow color F66-20 = Mercury vapor color F71-20 = F72-20 = F73-20 = F74-20 = F75-20 = Peach dichroic Amber dichroic Green dichroic Medium blue dichroic Yellow dichroic F76-20 = F77-20 = F78-20 = F79-20 = F80-20 = Red dichroic Dark blue dichroic Light blue dichroic Neutral density dichroic Magenta dichroic Lamps HP2050-NSP = 50-watt PAR20 lamp - narrow spot HP2050-NFL = 50-watt PAR20 lamp - narrow flood Lower wattage lamps and/or additional distributions may be available. See the Accessories & Technical Data section of this catalog for details. Lenses & Louvers DIF-20 = Diffused lens LSL-20 = Linear spread lens OSL-20 = Overall spread lens LVR-20 = Hex cell louver Glare Shields FH20 = Angled glare shield (specify finish: BK, BZ, CS, VE, WT) MOUNTING ACCESSORIES See the Accessories & Technical Data section of this catalog for details. NOTES AND FORMULAS • Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. • Footcandle values are initial. Apply appropriate light loss factors where necessary. • Bare lamp data shown. Consult lamp manufacturers to obtain detailed specifications for their lamps. Specifications and Dimensions subject to change without notice. Lumière • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADL032489 Halogena 50W Med 120V PAR20 FL 25D CL 1CT Page 1 of 3 O3 Halogena 50W Med 120V PAR20 FL 25D CL 1CT | Save PDF | Open PDF General PRODUCT DATA Product Number 389163 Full product name Halogena 50W Med 120V PAR20 FL 25D CL 1CT Ordering Code 50PAR20/HAL/NFL30 Pack type 1 Lamp in a Folding Carton Pieces per pack 1 Packs per case 6 Pack UPC 046677229115 EAN2US - Case Bar Code 50046677389166 Successor Product number - Wattage[W ] 50W Base Med [Medium] Voltage[V ] 120V Bulb PAR20 [PAR 20inch/63mm] Beam Description FL [Flood] Beam Angle[D ] 25D Bulb Finish CL [Clear] Packing Type 1CT [1 Lamp in a Folding Carton] Base Information Brass[Brass Base] Bulb Material Hard Glass Reflector Finish Aluminized Filament Shape CC-8[Axial] Operating Position Universal[Universal] Packing Configuration 6 Atmosphere Gas Rated Avg. Life[hr ] 3000 Approx. MBCP[cd ] 900 Color Rendering Index[Ra8 ] 100 Color Temperature[K ] 2800 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 Halogena 50W Med 120V PAR20 FL 25D CL 1CT Page 2 of 3 Initial Lumens[Lm ] 525 Max Overall Length (MOL) - C[in ] 3.375 Diameter D[in ] 2.5 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 Halogena 50W Med 120V PAR20 FL 25D CL 1CT Page 3 of 3 Dimensions ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 O4 M9700 SERIES METAL HALIDE 175 WATT MAX. MODULAR IN-GRADE LUMINAIRE DOUBLE LENS DESCRIPTION: The M9700 series modular in-grade lights are Multi-Purpose units designed for Flush Mounting in a variety of substrates or materials. The M9700’s are used to uplight Architectural and Landscape features. The units consist of a Factory –Sealed, thermally protected Lamp Module. Power Module is in a secured Rough-In section (RIS) which includes Channeled Convective Cooling, an integral Junction Box, and Door Assembly. The double lensed version offers Lamp Module Aiming and feature Aim-Lock™ to allow maintenance and relamping without re-aiming. The M9700 has a small footprint with a cylinder configuration. TYPE ___________________________________ MODEL #: ______________________________ ELECTRICAL ENTRIES/JUNCTION BOX: Two PG 16 or two 3/4" NPT bottom openings, standard. One hole is provided with IP68 cord seal that accepts ø10mm to ø14 mm cable (outside U.S. only). Second hole plugged. Box suitable for through branch wiring. Splicing volume 52 cu. in. ACCESSORIES: Internal Glare Control, Internal Honeycomb Louvers, Rock Guards, Trim Rings, Re-enterable Potting Compound, Polycarbonate Covers, External Glare Shields are available. NOTE: HYDREL RESERVES THE RIGHT TO CHANGE ANY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973) SPECIFICATIONS: DOOR FINISH: Cast aluminum, cast bronze, cast aluminum or bronze with stainless perforated trim insert or Stainless Steel. Round or square with two stainless steel captive fasteners that lock the Lamp Module into the Rough-In Section. ROUGH-IN SECTION: Injection molded polymer with integral junction box for branch wiring, U.V. stabilized, impact and corrosion resistant for use in all types of environ- ments. Houses Power Module, Lamp Modules and finishing components. Adjustment ring provides 360° aim rotation with keyed section to receive Lamp Module. Ring locks into position with stainless steel fasteners. RIS has a cylinder/vault configuration. 12 (305) LAMP MODULE: Stainless steel, sealed and purged of all moisture with silicone gaskets, stainless steel clamp band and single fastener. Electrical connection to Lamp Module is done through submersible connector with gold-plated contacts. THERMALLY PROTECTED. LAMP INCLUDED M9740 MODEL LAMP TYPES: See ordering guide. If a specific lamp is desired, specify manufacturer's lamp number, most lamps can be supplied. LAMP INCLUDED. 13 (330) VOLTAGES: 120V, 208V, 240V, 277V, 347V - 60 Hz, 220V, 230V, 240V - 50 Hz. Some restrictions may apply. LIGHT DISTRIBUTIONS (Non Reflectorized Lamps): TSP (G-12 T6 Lamps) SP (E-17, Elliptical) NFL (E-17, Elliptical, T6) MFL (E-17, Elliptical, T6) WFL (E-17, Elliptical) WWD (E-17, Elliptical) FINISHING SECTION: Double Lens: Includes 360° Aim-LockTM Module Support Ring, Door Assembly, Tilt Ring, and Module Indexing Segment providing maintenance and relamping without re-aiming. The Lamp Module is suspended below the door lens in a surface adjustable, 15° tilt mechanism. The insulating air layer reduces surface temperatures. Active lenses are available to bend beams (10° tilt and 20° tilt). POWER MODULE: Ballast is encapsulated in a custom-heat dissipating epoxy resin to eliminate all moisture intrusion to the ballast. Provided with submersible rated cord/connector for connection to integral junction box and lamp module. HID ballasts are magnetic. THERMALLY PROTECTED. HYDREL is a registered trademark of Lithonia Lighting M9720 MODEL STAINLESS STEEL DOOR 12 (305) 1 3/4 (45) 13 (330) 20 (508) M9740 MODEL STAINLESS STEEL DOOR PATENT PENDING UL/CE 12881 BRADLEY AVENUE, SYLMAR, CALIFORNIA 91342 • PHONE: 818/362-9465 • FAX: 818/362-6548 HYDREL STANDARD DATA SHEET/M9720 1/2002 FIXTURE OPTIONS Ordering and Specification Guide M9720 A 35MT6 120 TSP 34BNPT STR Model: M9720 M9740 Round Double Lens Square Double Lens Material: A Aluminum B Bronze ABL Aluminum with black paint ASP Aluminum with stainless perf.* BBP Bronze with brass perf.* BSP Bronze with stainless perf.* SS Stainless steel *ASP, BBP, BSP not available with M9740 (square double lens) model Lamp Type: (Lamp Included) US European HID 50S (HPS) E17, med. base Elliptical, E27 base 70S (HPS) E17, med. base Elliptical, E27 base* 100S (HPS) E17, med. base Elliptical, E27 base* 150S (HPS) E17, med. base E26** 50M (MH) E17, med. base N/A 70M (MH) E17, med. base Elliptical, E27 base 100M (MH) E17, med. base Elliptical, E27 base 150M (MH) E17, med. base Elliptical, E27 base 175M (MH) E17, med. base N/A 50H (MV) E17, med. base Elliptical, E27 base 75H (MV) E17, med. base N/A 80H (MV) N/A Elliptical, E27 base 100H (MV) E17, med. base Elliptical, E27 base 175H (MV) E17, med. base N/A 35MT6 (MH) T6, G-12 base T-6, G12 base 70MT6 (MH) T6, G-12 base T-6, G12 base 150MT6 (MH) T6, G-12 base T-6, G12 base HID, PAR Lamps (PAR-38, med. base)*** P3870M WFL (MH, 70W, wide flood) P3870M FL (MH, 70W, flood) P3870M SP (MH, 70W, spot) P38100M WFL (MH, 100W, wide flood) P38100M FL (MH, 100W, flood) P38100M SP (MH, 100W, spot) P38100H FL (MV, 100W, flood) P38100H SP (MV, 100W, spot) P38175H FL (MV, 175W, flood) P38175H SP (MV, 175W, spot) P38175M FL (MH, 175W, flood) P38175M SP (MH, 175W, spot) ***HID PAR lamps not available with E27 base **Not CE listed *Note: No internal accessories available with E27 base 70S or 100S Voltage: 60HZ 50HZ 120 22050HZ 208 23050HZ 220 24050HZ 240 277 347 Not all Voltage/Lamp combinations are available, consult factory for more information. HYDREL is a registered trademark of Lithonia Lighting Distributions: TSP (G-12 T6 Lamps) SP (E-17, Elliptical, PAR-38) NFL (E-17, Elliptical, T6) MFL (E-17, Elliptical, T6, PAR-38) WFL (E-17, Elliptical, PAR-38) WWD (E-17, Elliptical) Conduit Entries: 12BNPT 1/2" NPT bottom 12SNPT 1/2" NPT side 34BNPT 3/4" NPT bottom 34SNPT 3/4" NPT side 1BNPT 1" NPT bottom PG16B PG16 bottom PG16S PG16 side Accessories: FLC5 5° Axial Spread Lens GS Glare Shield++ IHL38 Internal Honeycomb Louver (PAR-38 Lamps) IHL Internal Honeycomb Louver (Non-Adjustable) ISS Internal Source Shield (150W max, Elliptical and T-6 lamps only) LC Polycarbonate Protective Cover++ RG Rockguard++ STR Stainless Steel Trim Ring, Round STS Stainless Steel Trim Ring, Square FLC10 10° Tilt Lens FLC20 20° Tilt Lens PC2112 20 cu. in. Re-enterable Potting Compound WWL Wall Wash Louver ++ Not available with Stainless Steel (SS) model For Replacement Parts Consult Factory 12881 BRADLEY AVENUE, SYLMAR, CALIFORNIA 91342 • PHONE: 818/362-9465 • FAX: 818/362-6548 HYDREL STANDARD DATA SHEETS/M9720 1/2002 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Page 1 of 3 O4 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB | Save PDF | Open PDF General PRODUCT DATA Product Number 233684 Full product name MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Ordering Code MHC100/U/MP/3K ALTO Pack type 1 Sleeve Open End Pieces per pack 1 Packs per case 12 Pack UPC 046677233686 EAN2US - Case Bar Code 50046677233681 Successor Product number - Wattage[W ] 100W Color Code 830 [CCT of 3000K] Base Med [Medium] Bulb ED17P [Diameter: 2.125 inch Protected] Bulb Finish CL [Clear] Feature ALTO+FB [ALTO® + FadeBlock™] Base Information Brass[Brass Base] Bulb Material Hard Glass Execution Protected Operating Position Universal[Universal] Packing Type 1SL[1 Sleeve Open End] Packing Configuration 12 Rated Avg. Life[hr ] 16000 Mercury Weight[mg ] 7.2 ANSI Code HID M140/M90/O Lamp Voltage[V ] 101 Color Rendering Index[Ra8 ] 85 Color Designation Warm White Color Temperature[K ] 3000 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Initial Lumens[Lm ] Page 2 of 3 8600 Design Mean Lumens[Lm ] 6450 Light Center Length L [inch][in ] 3.438 Max Overall Length (MOL) - C[in ] 5.438 Diameter D[in ] 2.125 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 100W/830 Med ED17P CL ALTO+FB Page 3 of 3 Dimensions ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 O4 Metal Halide Lamp Ballast Catalog Number 72C5381 For 100W M90/M140 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 10.50" CASE "F-1" 2.63" 11.13" 3.19" 11.75" Capacitor: INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±12% Lamp Watts LINE CURRENT (Amps) Operating................................................... 1.10 0.48 Open Circuit............................................... 2.55 1.10 Starting...................................................... 2.20 0.95 UL TEMPERATURE RATINGS Insulation Class A (105°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 277 INPUT VOLTAGE AT LAMP DROPOUT........................... 72 166 INPUT WATTS 125 RECOMMENDED FUSE (Amps)..................................... 6 3 CORE and COIL Dimension (A) Dimension (B) Weight (lbs.) 11 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads Volts (min.) Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 1600 2 seconds 2000 Open Circuit Voltage Test (Volts) 250-305 Short-Circuit Current Test (Amps) Secondary Current 1.30-1.60 Input Current.............................................. 0.70 0.30 1.10 0.50 - - - Wiring Diagram: All Lead Lengths 12" 277 V The capacitor is included as part of the potted assembly. 120V COMMON YELLOW/BLUE BLACK BALLAST WHITE RED LAMP GROUND CASE F-Can Wiring Diagram Ordering Information Ignitor: IN CAN Order Suffix Description The ignitor is included as part of the potted assembly. Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 90°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 09/03/99 05 ENGINEERED LIGHTING PRODUCTS HITW-EX SERIES RECESSED Hole In The Wall Light Niche For Exterior Stucco Construction Wall Washer Indirect Floor Washer Ideal placement is 18˝ to 30˝ from the bottom edge of fixture to the ground. WL-2 O5 ENGINEERED LIGHTING PRODUCTS HITW-EX SERIES RECESSED Hole In The Wall Light Niche For Exterior Stucco Construction SYSTEM 7/8˝ Recessed, fiberglass reinforced, composite fixture for use in exterior stucco construction. The cast fixture appears to be part of the architecture and looks like a custom formed “light niche” that blends with any exterior motif. Non I.C. Rated. UL/CUL Wet Location listed. 16˝ 17-1/2˝ 14-1/4˝ 16˝ 17-1/2˝ 6˝ SPECIFICATIONS Recessed fixture for use with a 20 watt Incandescent, 13 watt PL, or 26 watt Quad lamp. The cast fixture houses a ballast box with heat sink that includes wiring, socket, ballast and reflector. Incandescent fixture also has thermal protector. Fluorescent fixtures provide knock-outs for through wiring. Casting is secured to the 20 gauge electro-plated galvanized steel fixture back box and a 18 gauge electro-plated galvanized steel frame with lexan lens and silicone gaskets seal the lamp compartment. Frame, ballast box, and fixture back box are TGIC polyester powder coated. Composite casting is water and high impact resistant. Use “Weld-crete” to finish surface to match exterior stucco. OPTIONS Ballast Low Temp 120 HPF Electronic (Standard) Low Temp 277 HPF Electronic ① Fixture mounts directly to studs that are 16˝ on center. ③ Finish & paint, then carefully make electrical connections. 13˝ 4-1/16˝ Section Front View Model No. 120 IN-HITW-EX 113 PL-HITW-EX 126 QD-HITW-EX Lamp 20 watt Mini Can Incandescent 13 watt PL 26 watt Quad NOTE: All fluorescent fixtures have electronic ballast with -20° starting temperature. Installation should be coordinated between electrician and exterior finish contractor. 32W Triple Tube, consulted manufacturer. The exterior finish contractor must provide waterproof seal where fixture joins the building. See Installation Instructions. ② Allow at least 16˝ of additional conduit to connect power. ④ The finished fixture blends with any architecture. © 2003 Engineered Lighting Products. 1997/Rev. 2002 10768 LOWER AZUSA ROAD • EL MONTE • CA 91731 • 626-579-0943 • FAX: 626-579-6803 • E-mail: elp2@aol.com • WEB: www.elplighting.com PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 1 of 2 O5 PL-T Triple 4-Pin Fluorescent Lamp Feature High color rendering, high efficacy lamps feature 4-pin base for use with preheat, rapid start, electronic and dimming circuits. Featuring ALTO® Lamp Technology Watts 32 Bulb PL-T Base GX24q-3 Product 046677-26832-6 Number Ordering PL-T 32W/830/4P/ALTO Code Generic CFTR32W/GX24q/830 Designation Package 12 Quantity Description 3000K CRI 82 Avg. Hrs. 10,000 Life Design 2040 Lumens M.O.L. 5 5/8 Lumens 2400 Images Literature Other Information + ALTO Product Logo + ALTO Family Brochure • Energy Saving Product + Family Photo + MSDS S08-98001 + Printable Page + Product Photo + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + This Product Contains Amalgam + High Color Rendering Lamp Features ALTO® Lamp Technology + Rated average life under specified test conditions with Programmed Start ballasts with lamps + turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 2 of 2 + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. Information for this product last modified on September 25, 2001 ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 O7 Metal Halide Lamp Ballast Catalog Number 71A5282 For 70W M98/M143 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 3 X 4 CORE - 2 COIL UNIT 5.10 " 4.50" 0.7" 1.0" A B MAX. 0.25" WIDE 2 SLOTS 3.95" 3.50" 4 HOLES CLEARED FOR #10 THRU-BOLTS 2.45" 2.80" Capacitor: 7C080L33-R 2.90" INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±7% Lamp Watts LINE CURRENT (Amps) Operating................................................... 0.80 0.35 Open Circuit............................................... 1.90 0.80 Starting...................................................... 0.55 0.25 UL TEMPERATURE RATINGS Insulation Class H(180°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 255 INPUT VOLTAGE AT LAMP DROPOUT........................... 90 208 INPUT WATTS 88 RECOMMENDED FUSE (Amps)..................................... 4 2 CORE and COIL Dimension (A) 1.45 Dimension (B) 2.75 Weight (lbs.) 5 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads 8.0 Volts (min.) 280 Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 2000 2 seconds 2500 Open Circuit Voltage Test (Volts) 230-280 Short-Circuit Current Test (Amps) Secondary Current 0.95-1.25 Input Current.............................................. 0.55 0.25 0.80 0.45 - - - Wiring Diagram: LAMP CAP LINE V LINE V X3 X1 IGNITOR CAP LAMP LINE V X2 COM LINE V Capacitance: Dia/Oval Dim: Height: Temp Rating: 8 1.25 2.9 105°C COM COM Fig. K Ordering Information Ignitor: LI533-H4 Order Suffix 500D. 510D. 600. 610. Description Ballast With Ignitor and Dry Film Capacitor Ballast w/Welded Bracket, Ignitor, & Dry Film Capacitor Ballast and Ignitor, No Capacitor Ballast with Welded Bracket and Ignitor, No Capacitor Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 105°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 11/08/00 05 ENGINEERED LIGHTING PRODUCTS HITW-EX SERIES RECESSED Hole In The Wall Light Niche For Exterior Stucco Construction Wall Washer Indirect Floor Washer Ideal placement is 18˝ to 30˝ from the bottom edge of fixture to the ground. WL-2 O5 ENGINEERED LIGHTING PRODUCTS HITW-EX SERIES RECESSED Hole In The Wall Light Niche For Exterior Stucco Construction SYSTEM 7/8˝ Recessed, fiberglass reinforced, composite fixture for use in exterior stucco construction. The cast fixture appears to be part of the architecture and looks like a custom formed “light niche” that blends with any exterior motif. Non I.C. Rated. UL/CUL Wet Location listed. 16˝ 17-1/2˝ 14-1/4˝ 16˝ 17-1/2˝ 6˝ SPECIFICATIONS Recessed fixture for use with a 20 watt Incandescent, 13 watt PL, or 26 watt Quad lamp. The cast fixture houses a ballast box with heat sink that includes wiring, socket, ballast and reflector. Incandescent fixture also has thermal protector. Fluorescent fixtures provide knock-outs for through wiring. Casting is secured to the 20 gauge electro-plated galvanized steel fixture back box and a 18 gauge electro-plated galvanized steel frame with lexan lens and silicone gaskets seal the lamp compartment. Frame, ballast box, and fixture back box are TGIC polyester powder coated. Composite casting is water and high impact resistant. Use “Weld-crete” to finish surface to match exterior stucco. OPTIONS Ballast Low Temp 120 HPF Electronic (Standard) Low Temp 277 HPF Electronic ① Fixture mounts directly to studs that are 16˝ on center. ③ Finish & paint, then carefully make electrical connections. 13˝ 4-1/16˝ Section Front View Model No. 120 IN-HITW-EX 113 PL-HITW-EX 126 QD-HITW-EX Lamp 20 watt Mini Can Incandescent 13 watt PL 26 watt Quad NOTE: All fluorescent fixtures have electronic ballast with -20° starting temperature. Installation should be coordinated between electrician and exterior finish contractor. 32W Triple Tube, consulted manufacturer. The exterior finish contractor must provide waterproof seal where fixture joins the building. See Installation Instructions. ② Allow at least 16˝ of additional conduit to connect power. ④ The finished fixture blends with any architecture. © 2003 Engineered Lighting Products. 1997/Rev. 2002 10768 LOWER AZUSA ROAD • EL MONTE • CA 91731 • 626-579-0943 • FAX: 626-579-6803 • E-mail: elp2@aol.com • WEB: www.elplighting.com PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 1 of 2 O5 PL-T Triple 4-Pin Fluorescent Lamp Feature High color rendering, high efficacy lamps feature 4-pin base for use with preheat, rapid start, electronic and dimming circuits. Featuring ALTO® Lamp Technology Watts 32 Bulb PL-T Base GX24q-3 Product 046677-26832-6 Number Ordering PL-T 32W/830/4P/ALTO Code Generic CFTR32W/GX24q/830 Designation Package 12 Quantity Description 3000K CRI 82 Avg. Hrs. 10,000 Life Design 2040 Lumens M.O.L. 5 5/8 Lumens 2400 Images Literature Other Information + ALTO Product Logo + ALTO Family Brochure • Energy Saving Product + Family Photo + MSDS S08-98001 + Printable Page + Product Photo + View Compatible Ballasts + Send this Link + Bookmark this Page Footnotes + This Product Contains Amalgam + High Color Rendering Lamp Features ALTO® Lamp Technology + Rated average life under specified test conditions with Programmed Start ballasts with lamps + turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 PL-T Triple 4-Pin Fluorescent Lamp 32 Watts Bulb PL-T Base GX24q-3 Product Numbe... Page 2 of 2 + Approximate Initial Lumens. The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. + Design Lumens are the approximate lamp lumen output at 40% of the lamp's Rated Average Life. This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions. Information for this product last modified on September 25, 2001 ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/cfl/displaycfl.php?id=131 4/3/2005 B5 ICF-2S26-H1-LD@120 Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status Electrical Specifications Lamp Type Num. of Lamp s CFM26W/GX24Q 1 CFM26W/GX24q 2 * CFM32W/GX24q 1 CFM42W/GX24q 1 CFQ26W/G24q 1 CFQ26W/G24q 2 CFS21W/GR10q 2 FT24W/2G11 2 Rated Lamp Watts Min. Start Temp (°F/C) Input Current (Amps) 26 26 32 42 26 26 21 24 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0.24 0.45 0.31 0.38 0.23 0.43 0.42 0.41 Wiring Diagram BLUE BLACK WHITE Ballast Factor MAX THD % Power Factor MAX Lamp Current Crest Factor B.E.F. 1.10 1.00 0.98 0.98 1.00 1.00 1.12 0.93 10 10 10 10 10 10 10 10 0.98 0.99 0.98 0.98 0.98 0.99 0.99 0.99 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 3.79 1.85 2.72 2.13 3.70 1.96 2.20 1.94 Enclosure WIRING: (2) LAMPS LINE Input Power (ANSI Watts) 29 54 36 46 27 51 51 48 SMARTMATE Electronic Programmed Start Series 120-277 50/60 HZ Active (1) LAMP BLUE BALLAST Y E L L O W GREEN RED RED Green Terminal must be Grounded The wiring diagram that appears above is for the lamp type denoted by the asterisk (*) Enclosure Dimensions Standard Lead Length (inches) Black White Blue Red Yellow Gray Violet in. 0.0 0.0 0.0 0.0 0 cm. in. Yellow/Blue Blue/White Brown Orange Orange/Black Black/White Red/White cm. OverAll (L) 4.98 " 4 49/50 12.6 cm Width (W) 2.4 " 2 2/5 6.1 cm Height (H) Mounting (M) 1.0 " 4.6 " 1 4 3/5 2.5 cm 11.7 cm Revised 09/02/2004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 ICF-2S26-H1-LD@120 Electrical Specifications Notes: Brand Name Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency Status SMARTMATE Electronic Programmed Start Series 120-277 50/60 HZ Active Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements. 1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11. Section II - Performance Requirements 2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start. 2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage and frequency) with no damage to the ballast. 2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker. 2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp. 2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application. 2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations. 2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.9 Ballast shall have a Class A sound rating. 2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting temperature of -30C (-20F) for primary lamp. 2.11 Ballast shall provide Lamp EOL Protection Circuit which meets NEMA recommendations. 2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. Section III - Regulatory Requirements 3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 Ballast shall be Underwriters Laboratories (UL) rated for use in air-handling spaces. 3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection. 3.5 Ballast shall comply with ANSI C82.11 where applicable. 3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated) except for RCF models which shall be Consumer (Class B). Section IV - Other 4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120XX-XX, ICF2S70-XX-XX and ICF2S4290C-XX-XX modesls). 4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. 4.4 Ballast shall be Advance Transformer part # _____________ or approved equal. Revised 09/02/2004 Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD ROSEMONT, ILLINOIS 60018 TELEPHONE: (847) 390-5000 FAX: (847) 390-5109 O6 Clikstrip UV-protected lens CLM Series CLM Series delivers low voltage linear lighting for outdoor applications such as building facades, signage, pedestrian Extruded lens clasps walkways and landscape accenting. The small scale shallow profile aluminum extrusion houses Clikstrip™ and offers many options for outdoor as well as indoor lighting. Features • Gasketed aluminum housing finished in satin anodized or painted. Blends well in all architectural environments. • Gasketed stamped aluminum end plates maintain a water resistant enclosure. • Extruded aluminum lens clasps, patent pending. Permits servicing of the fixture by removing the lens without tools. Consult factory for tamperproof option. • UV-protected clear polycarbonate lens. • Choice of mounting provides installation flexibility. • Choice of shielding options. Gasketed aluminum housing • Delivered from factory with Clikstrip™ installed – order separately. • Optional factory-installed parabolic lamp reflectors. • Requires remote power supply. • UL/c Listed wet location and IP64 rated for use with 10 watt max lamps in base up or base down position. Gasketed end plates O6 CLM Series Clikstrip™ miniature wet location CLM Series is delivered with factory installed Clikstrip™ which must be ordered separately Ardee’s Clikstrip™ product specification formula allows you to specify each component that will best achieve the lighting results you need. To specify a complete catalog number choose one item from the selection available in each module. CLX Series 0 Mounting CLX - TB for wiring in CLM Series housing 0 - mounted to CLM Series housing X Color X Clip Type XX X Unit of Nominal Length Measurement W- white C - standard standard sizes F - feet profile in 1' B - black chrome increments M - metric from 01' to 16' G - standard or half meter profile gold increments from 0.5 to N - high 4.5 meters profile chrome 08' X Center-to-Center Lamp Spacing S - standard 17/8" o.c. A - alternate 33/4" o.c. C - custom (O.C. dimension to be called out in product description) -X C Festoon Lamp Style Lamp Type* I - incandescent C - clear X Lamp Voltage 2 - 12 volt X Lamp Wattage 3 - 3 watt X - xenon F - frosted 4 - 24 volt 5 - 5 watt A - argon R - red 6 - 6 watt L - looped B - blue 8 - 8.5 watt W- LED element G - green 1 - 10 watt Y - yellow A - LED element AC R - high profile gold W- solar blue D - LED element DC or LED element Clikstrip™ LED Element 80 90 ZONAL LUMENS 10.4 70 28.4 38.2 36.3 60 LEDs are the newest choice of designers for energy efficient, low maintenance lighting applications. Our LED Elements combine energy efficiency and long life with low heat generation and high light intensity in a “lamp” specially designed to install into Clikstrip.™ White LED elements are standard but other colors are available for custom applications. 50 29.2 Features 21.2 • LED lamp color: 5000°K. LED lamp life: 60,000 hours. Consult factory for LED lamp color options. • Total power consumption: 1 watt. • Patent pending. 40 10.9 30 20 5.6 0 10 0 45 90 SPREAD DISTANCE 6" 152 mm 12" 305 mm 18" 457 mm 24" 610 mm 30" 762 mm 36" 914 mm 42" 1066 mm 48" 1219 mm 60" 1524 mm 72" 1829 mm 84" 2134 mm FC 432 108 48 27 17 12 9 7 4 3 2 3.1 Photometric report: WW2D Ordering information Test report number: Description: Part Numbers Rated lumens: WW2A WW4A WW2D Description White LEDs 12 VAC White LEDs 24 VAC White LEDs 12 VDC Class II only actual size Clikstrip™ Materials Specification extrusion UL/C recognized PES (polyethersulfone) with a thermal deflection temperature of 397°F. conductors Solid hard drawn copper. terminal block UL/C recognized part made with nylon (insulator polyamide) casing with nickel-plated brass contacts. lampholder clips Tempered spring steel finished in bright nickel or gold. 11729.0 18 1-watt white LED elements installed on 3' Clikstrip 12 volt DC power supply 10.2 per element O7 Job Name: CALLISTO-12 Fixture Type: Job Number: Distributor: Distributor P.O. : 1. H O U S I N G CL12 Housing: two-piece die-cast aluminum with internal component mounting bosses. 10.39" 3.45" 14.30" 13.38" 12" Door frame: one-piece die-cast aluminum secured with three phillips head screws. 9.81" Lens assembly: various clear or prismatic glass lens (beam dependant) gasketed to door to ensure a tight seal. 9.62" 0.18" EPA (fixture only): 0.62 2" FIXTURE WEIGHT: 28 LBS. The luminaire shall be cULus listed for wet locations and manufactured from UL-recognized components. (shown with optional eggcrate shield) 2. L A M P W A T T A G E METAL HALIDE (H.I.D.) ED17 HIGH PRESSURE SODIUM (H.I.D.) ED17 70 WATT METAL HALIDE (70MH) 100 WATT HIGH PRESSURE SODIUM (100HPS) 100 WATT METAL HALIDE (100MH) 150 WATT HIGH PRESSURE SODIUM (150HPS) 150 WATT METAL HALIDE (150MH) 175 WATT METAL HALIDE (175MH) Quartz WATTAGE PAR56 (500QTZ) 500 WATT QUARTZ HALOGEN (Electronic ballast available only in 70MH or 100MH) 3. B E A M P A T T E R N METAL HALIDE & HIGH PRESSURE SODIUM INCANDESCENT NARROW SPOT SPOT (SP) RECTANGULAR NARROW (RN) RECTANGULAR MEDIUM (RM) (NSP) RECTANGULAR WIDE (RW) MEDIUM FLOOD RECTANGULAR NARROW VERTICAL (RNV) Item Number: ORDER NUMBER: 1 RECTANGULAR MEDIUM VERTICAL (RMV) 2 3 RECTANGULAR WIDE VERTICAL (RWV) 4 5 FLOOD 6 (WFL) 7 8 9 10 MOUNTING OPTION SHIELD OPTION FINISH GENERAL OPTION YK CL12 HOUSING WIDE (MFL) LAMP WATTAGE BEAM PATTERN VOLTAGE BALLAST (FOR HID) MODEL STYLE 07 4. V O L T A G E 5. B A L L A S T (H.I.D. ONLY) 120 277 CORE & COIL 208 347 ELECTRONIC 240 480 6. M O D E L (C) YOKE (YK) (EB) (Ballast is an integral part of the fixture housing.) (Electronic ballast available only in 70WMH and 100WMH, and in 120 or 277 volt. Rated for -20 F (-28.9 C).) (Electronic ballast available only in 120 or 277 volts.) (Quartz available in 120 volt only.) (Core and coil ballast is high-power factor and rated for -20 F (-28.9 C).) 7. M O U N T I N G O P T I O N S BASE PLATE (BP) 0.56" (4) 6.00" DIA. BOLTCIRCLE WALL BRACKET (WB) 1.81" 1.16" 3/ 8" LOCKING BOLT CANBE MOUNTED TO2" PIPE (MAX) WITH 5/ 8" PIVOT U-BOLTS (U-BOLTS BOLT BY OTHERS) 3/ 4" MOUNTING HARDWARE 6.00" 3/ 4" MOUNTING HARDWARE 1.38" BASE PAD (PD) 2.06" I.D. 6.00" 2.38" O.D. SLIP FITTER 3.44" 3.13" 3.50" CASTDUCTILE IRON WALLBRACKETAND HORIZONTALSECTOR 6.25" 0.56" (4) 3.50" 4.50" .25" ALLCOMPONENTS STEEL. WELDCONSTRUCTION 8. O P T I O N A L S H I E L D S (SF) TOFIT2" (2.38" O.D.) PIPE TENONX 4.00" LONG (MIN.) REMOVABLE PIPE PLUGFOR 3/ 4" MOUNTING INSTALLING HARDWARE WATER-TITE CONNECTOR (SUPPLIED) 5.63" WATER-TITE CONNECTOR REMOVABLE SPLICE INSPECTION COVER CASTTENZALLOY FITTER REMOVABLE HOLE PLUGFOR 1/ 2" SET SIDE YOKE SCREWS MOUNTING EGGCRATE (EC) VER. LOUVER (VL) 6.17" HOR. LOUVER 7.90" 6.17" 6.17" 2.46" 7.90" 3.0" TOP SHIELD (TS) 6.17" 4.0" CUSTOM SHIELD (HL) 6.17"" 3.0" 6.17" (CS) The eggcrate is the only shield finished to match luminaire. Standard shield finish is black unless otherwise specified. 6.17" 9. F I N I S H 10. G E N E R A L O P T I O N S (BK) DARK BRONZE (BZ) WHITE (WH) NATURAL ALUMINUM (AL) NON-STANDARD (NS) INCLUDE LAMP BLACK (2" SCH. 40 STEELPIPE) (for use with SF option) 8.00" 5.50" .38" CASTDUCTILE IRON SURFACE BASE 6.00" DIA. BOLTCIRCLE 1.50" 1.50" 0.56" (4) (LP) SAFETY CABLE (SC) FUSE LUMINAIRE (FL) (SELECT 'LP' ONLY IF A LAMP IS TO BE INCLUDED) 70MH ED17 100HPS ED17 100MH ED17 150HPS ED17 150MH ED17 175MH ED17 500QTZ PAR56 REMARKS: S t e r n e r L i g h t i n g S y s t e m s I n c o r p o r at e d 351 LEWIS AVENUE WEST, P.O. BOX 805 WINSTED, MN 55395-0805 T E L 3 2 0 . 4 8 5 . 2 1 4 1 FA X 3 2 0 . 4 8 5 . 2 8 8 1 T O L L - F R E E 8 0 0 . 3 2 8 . 7 4 8 0 2/2002 w w w. s t e r n e r l i g h t i n g . c o m MasterColor CDM 70W/830 Med ED17P CL ALTO+FB Page 1 of 3 O7 MasterColor CDM 70W/830 Med ED17P CL ALTO+FB | Save PDF | Open PDF General PRODUCT DATA Product Number 233668 Full product name MasterColor CDM 70W/830 Med ED17P CL ALTO+FB Ordering Code MHC70/U/MP/3K ALTO Pack type 1 Sleeve Open End Pieces per pack 1 Packs per case 12 Pack UPC 046677233662 EAN2US - Case Bar Code 50046677233667 Successor Product number - Wattage[W ] 70W Color Code 830 [CCT of 3000K] Base Med [Medium] Bulb ED17P [Diameter: 2.125 inch Protected] Bulb Finish CL [Clear] Feature ALTO+FB [ALTO® + FadeBlock™] Base Information Brass[Brass Base] Bulb Material Hard Glass Execution Protected Operating Position Universal[Universal] Packing Type 1SL[1 Sleeve Open End] Packing Configuration 12 Rated Avg. Life[hr ] 16000 Mercury Weight[mg ] 6.6 ANSI Code HID M143/M98/O Lamp Voltage[V ] 100 Color Rendering Index[Ra8 ] 85 Color Designation Warm White Color Temperature[K ] 3000 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 70W/830 Med ED17P CL ALTO+FB Initial Lumens[Lm ] Page 2 of 3 5900 Design Mean Lumens[Lm ] 4365 Light Center Length L [inch][in ] 3.438 Max Overall Length (MOL) - C[in ] 5.438 Diameter D[in ] 2.125 http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 MasterColor CDM 70W/830 Med ED17P CL ALTO+FB Page 3 of 3 Dimensions ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.prismaecat.lighting.philips.com/LightSite/Whirlwind.aspx?eca=LNPPLA&cpf=... 4/3/2005 O7 Metal Halide Lamp Ballast Catalog Number 71A5282 For 70W M98/M143 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 3 X 4 CORE - 2 COIL UNIT 5.10 " 4.50" 0.7" 1.0" A B MAX. 0.25" WIDE 2 SLOTS 3.95" 3.50" 4 HOLES CLEARED FOR #10 THRU-BOLTS 2.45" 2.80" Capacitor: 7C080L33-R 2.90" INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±7% Lamp Watts LINE CURRENT (Amps) Operating................................................... 0.80 0.35 Open Circuit............................................... 1.90 0.80 Starting...................................................... 0.55 0.25 UL TEMPERATURE RATINGS Insulation Class H(180°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 255 INPUT VOLTAGE AT LAMP DROPOUT........................... 90 208 INPUT WATTS 88 RECOMMENDED FUSE (Amps)..................................... 4 2 CORE and COIL Dimension (A) 1.45 Dimension (B) 2.75 Weight (lbs.) 5 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads 8.0 Volts (min.) 280 Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 2000 2 seconds 2500 Open Circuit Voltage Test (Volts) 230-280 Short-Circuit Current Test (Amps) Secondary Current 0.95-1.25 Input Current.............................................. 0.55 0.25 0.80 0.45 - - - Wiring Diagram: LAMP CAP LINE V LINE V X3 X1 IGNITOR CAP LAMP LINE V X2 COM LINE V Capacitance: Dia/Oval Dim: Height: Temp Rating: 8 1.25 2.9 105°C COM COM Fig. K Ordering Information Ignitor: LI533-H4 Order Suffix 500D. 510D. 600. 610. Description Ballast With Ignitor and Dry Film Capacitor Ballast w/Welded Bracket, Ignitor, & Dry Film Capacitor Ballast and Ignitor, No Capacitor Ballast with Welded Bracket and Ignitor, No Capacitor Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 105°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 11/08/00 P1 RTs – ROUND TAPERED STEEL POLES ORDER E XA MPLE (1) (2) (3) (4) (5) (6) (7) RTS20 5.9 x 3.1 0.120 28 H PRP BK ORDERING SEQUENCE DIAMETER (TAPERED) (7) (4) RTS16 PRP See Pole Data Table Below DF Polyurethane Finish Duplex Groundfault Receptacle (15 amp, mounted 24" above grade) BK Black BZ Dark Bronze (arm mount fixtures only) WH White Break-Away Banner Arm Coupling AL Natural Aluminum NS Non-Standard Finish PRP Pole Top Photocell Receptacle BN BZ (can use 0.75" or 1.25" pipe arms) (consult factory for specific ordering info.) (consult factory) SEE FIXTURE DETAIL NOTES: 1) RTS12, 16, 20, 25, 30, 35, & 39 are available in 0.120" wall standard. 2) '10' applies to both arm & yoke mount fixtures. 3) See below table for dimensions & bolt info. P O L E D ATA 14" 4.6" x 3.0" 11 ga. 10.9 5.2" x 3.0" 11 ga. 8.5 5.9" x 3.1" 11 ga. 9.2 6.5" x 3.0" 11 ga. 7.7 6.9" x 3.0" 11 ga. 6.2 7.6" x 3.0" 11 ga. 6.3 8.4" x 3.0" 11 ga. 6.0 NOTES: Responsibility lies with the specifier for correct pole selection based on local codes and standards for the job location. (see Wind Map on page 13 for details) 9 P2 RTs – ROUND TAPERED STEEL POLES ORDER E XA MPLE (1) (2) (3) (4) (5) (6) (7) RTS20 5.9 x 3.1 0.120 28 H PRP BK ORDERING SEQUENCE DIAMETER (TAPERED) (7) (4) RTS16 PRP See Pole Data Table Below DF Polyurethane Finish Duplex Groundfault Receptacle (15 amp, mounted 24" above grade) BK Black BZ Dark Bronze (arm mount fixtures only) WH White Break-Away Banner Arm Coupling AL Natural Aluminum NS Non-Standard Finish PRP Pole Top Photocell Receptacle BN BZ (can use 0.75" or 1.25" pipe arms) (consult factory for specific ordering info.) (consult factory) SEE FIXTURE DETAIL NOTES: 1) RTS12, 16, 20, 25, 30, 35, & 39 are available in 0.120" wall standard. 2) '10' applies to both arm & yoke mount fixtures. 3) See below table for dimensions & bolt info. P O L E D ATA 14" 4.6" x 3.0" 11 ga. 10.9 5.2" x 3.0" 11 ga. 8.5 5.9" x 3.1" 11 ga. 9.2 6.5" x 3.0" 11 ga. 7.7 6.9" x 3.0" 11 ga. 6.2 7.6" x 3.0" 11 ga. 6.3 8.4" x 3.0" 11 ga. 6.0 NOTES: Responsibility lies with the specifier for correct pole selection based on local codes and standards for the job location. (see Wind Map on page 13 for details) 9 T1 Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Accent lighting applications where color, extended lamp life and efficiency are important. H.I.D. LTD REFL CONSTRUCTION Polyester powder painted aluminum ballast housing. Polyester powder painted aluminum socket housing and protective cowl. Open Reflector Color-Corrected or Standard Metal Halide ED-17, E-17 or BD-17 Lamp Metal yoke rotates 330° horizontally and up to 90° from vertical. Two opposed knobs lock vertical position. Injection-molded track mounting adaptor for easy attachment to 1 or 2 circuit Lithonia Track. Available with optional direct J-box mount. Track mounted fixtures include a secondary locking clip. Available in white or black finishes. OPTICAL SYSTEM Optical system designed specifically for clear, medium-base metal halide lamp. Spun, clear anodized aluminum reflector available in spot, narrow flood or wide flood distributions. ELECTRICAL SYSTEM Medium-base porcelain socket with nickel-plated screw shell (open reflector requires protected lamp). Available for 50, 70, 100 or 150 watt metal halide lamps (see sheet 115-LTDREFL for 50 watt, 120-LTD-REFL for 70 watt, and 125-LTD-REFL for 100 watt). High power factor, core and coil ballast. CM option provides direct J-box mount and ballast that operates with either 120 or 277 volt. LISTING Fixtures are UL 1574 or 1598 listed. Listed and labeled to comply with Canadian Standards. 7-3/4 (19.7) EMB: 15-1/16 (38.3) EMB: 8-5/8 (14.3) 8-3/8 (21.3) All dimensions are inches (centimeters). ORDERING INFORMATION Example: LTD REFL 150M NFL EMB WH Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. LTD REFL 150M Series Head Style Wattage/lamp Distribution LTD REFL Open reflector 150M 150W metal halide SP Spot EMB Electromagnetic ballast NFL Narrow flood WFL Wide flood 1 2 Ballast NOTES: 1 Supplied with socket designed for protected lamp unless CGL option is selected. 2 Available with clear anodized finish only. 3 Philips ceramic metal halide lamp shipped standard. Consult factory for other lamp options. 4 CM option with EMB ballast uses 120/277 dual tap ballast. Downlighting and Track Sheet#:LTD-REFL-150M Finish WH White DBL Black Options CM4 For direct mount to 4" octagon J-box (by others) CGL Clear tempered glass lens WLP 3 With lamp (shipped separately) HID-160 LTD REFL Open Reflector/Color Corrected or Standard Metal Halide Distribution curve Distribution data Output data Coefficient of utilization Illuminance Data at 30" Above Floor for a Single Luminaire LTD REFL 150M SP, (1) MHC150/U/MP/4K, 12400 lumens per lamp, 0.13 s/mh, test no. LTL8975 From 0° o 90 42000 84000 126000 168000 210000 0o cp. Lumens 0° 206295 5° 66831 4860 15° 3082 1094 25° 1279 576 45o 35° 1138 734 45° 1885 1311 55° 397 533 65° 142 136 75° 76 117 85° 13 52 90° 0 Zone Lumens %lamp 0°-30° 6529.9 0°-40° 7263.6 0°-60° 9107.5 0°-90° 9412.5 90°-180° 0.0 0°-180° 9412.5 52.7 58.6 73.4 75.9 0.0 75.9* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 84 79 75 71 68 65 63 61 59 57 83 76 71 67 64 61 59 57 55 54 83 78 74 70 67 65 62 60 59 57 81 75 71 67 64 61 59 57 55 54 80 75 72 69 66 63 61 60 58 57 78 73 69 66 63 60 58 56 55 54 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 6819.7 3667.5 2285.8 1559.9 1131.9 50% 10% beam angle 7.5° beam angle 16.6° fc at fc at Beam beam Beam beam diameter edge diameter edge 0.7 3409.8 1.0 1833.7 1.2 1142.9 1.5 779.9 1.8 566.0 1.6 2.2 2.8 3.4 3.9 682.0 366.7 228.6 156.0 113.2 LTD REFL 150M NFL, (1) MHC150/U/MP/4K, 12400 lumens per lamp, 0.51 s/mh, test no. LTL8976 From 0° 90o 6400 12800 45o 19200 25600 32000 0o cp. Lumens 0° 28913 5° 31549 2769 15° 14470 3786 25° 1567 867 35° 996 631 45° 983 757 55° 311 376 65° 80 82 75° 59 58 85° 29 37 90° 0 Zone Lumens %lamp 0°-30° 7422.7 0°-40° 8053.8 0°-60° 9186.3 0°-90° 9363.3 90°-180° 0.0 0°-180° 9363.3 59.9 64.9 74.1 75.5 0.0 75.5* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 84 79 75 71 68 65 62 60 58 56 82 76 71 67 64 61 58 56 54 52 83 78 74 70 67 64 62 59 57 55 81 75 71 67 63 61 58 56 54 52 79 75 72 69 66 63 61 59 57 55 78 73 69 66 63 60 57 55 53 52 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 955.8 514.0 320.4 218.6 158.6 50% 10% beam angle 28.7° beam angle 41.9° fc at fc at Beam beam Beam beam diameter edge diameter edge 2.8 3.8 4.9 5.9 6.9 477.9 257.0 160.2 109.3 79.3 4.2 5.7 7.3 8.8 10.3 95.6 51.4 32.0 21.9 15.9 LTD REFL 150M WFL, (1) MHC150/U/MP/4K, 12400 lumens per lamp, 0.95 s/mh, test no. LTL8978 o 90 1200 2400 45o 3600 4800 6000 0o From 0° cp. 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 5852 5845 5512 4058 2742 2016 814 345 142 43 0 Lumens 556 1528 1860 1729 1563 847 346 155 45 Zone Lumens %lamp 0°-30° 3944.1 0°-40° 5673.6 0°-60° 8083.7 0°-90° 8630.4 90°-180° 0.0 0°-180° 8630.4 31.8 45.8 65.2 69.6 0.0 69.6* *Efficiency ρf 20% ρc 80% 70% 50% ρw 50% 30% 50% 30% 50% 30% 1 2 3 4 5 6 7 8 9 10 75 68 62 56 51 47 43 40 37 35 73 64 57 51 46 42 38 35 32 30 74 67 61 55 51 46 43 40 37 35 72 63 56 51 446 42 38 35 32 30 71 64 59 54 49 45 39 39 36 34 69 62 55 50 45 41 34 34 32 30 Initial fc Mount at beam height center 8' 10' 12' 14' 16' 193.5 104.0 64.8 44.2 32.1 50% beam angle 51° fc at Beam beam diameter edge 5.2 7.2 9.1 11.0 12.9 96.7 52.0 32.4 22.1 16.1 10% beam angle 94.9° fc at Beam beam diameter edge 12.0 16.3 20.7 25.0 29.4 Philips MHC150/U/MP/3K has a rated lamp life of 9,000 hours. NOTES: 1 For electrical characteristics, refer to electrical data tab. 2 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications are based on the most current available data and are subject to change without notice. Lithonia Lighting Sheet#:LTD-REFL-150M ©2001 Acuity Lighting Group, Inc. 06/03 LTD-REFL-150M.p65 Acuity Lighting Group, Inc. Recessed Downlighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4935 Fax: 770-860-3106 In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3 www.lithonia.com 19.3 10.4 6.5 4.4 3.2 Protected MasterColor Ceramic Metal Halide Lamp 70 Watts Bulb PAR-30L Base Med. ... Page 1 of 2 T1 Protected MasterColor® Ceramic Metal Halide Lamp Feature PAR Style. Open or Enclosed Luminaires. Lifetime Color Stability Within +/- 200K Watts 70 Bulb PAR-30L Base Med. Product Number 046677-23221-5 Ordering Code CDM70/PAR30L/M/FL Package Quantity 6 Description G, PAR WISO Flood 40 degrees FadeBlock 10,000 MBCP ANSI M143/M98/O Code/Ballast Ref. CRI 82 Rated Avg. Life 9000 (Hrs.) M.O.L. 4 3/4 Approximate 4850 Initial Lumens Approximate 3880 Mean Lumens CCT 3000 Images Literature Other Information + Family Photo + Family Brochure + Printable Page + Product Logo + MSDS S15-95004 + View Compatible Ballasts + Product Photo + MSDS S15-95005 + Photometric Data + Send this Link + Bookmark this Page † Heat resisting glass bulb + Technical Data Sheet Footnotes + ANSI CODE RATING, E - Enclosed, O - Open, S - Open or Enclosed + Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps. + Approximate lumen values listed are for vertical operation of the lamp. http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=28 4/3/2005 Protected MasterColor Ceramic Metal Halide Lamp 70 Watts Bulb PAR-30L Base Med. ... Page 2 of 2 + Click here for Recommended Warnings, Cautions and Operating Instructions. + Approximate lumen output at 40% of lamp rated average life. + Requires a ballast specified or approved for Philips Metal Halide lamp or one designed to the indicated ANSI Standard. A pulse ignitor is required. Sockets and wiring must withstand starting pulse. + Supply volts must be +/- 5% of rated ballast line volts for reactor type and +/- 10% for CWA or electronic ballasts. + UV filtered design (Fade-Block™). MasterColor® Metal Halide Lamps are not recommended for use on dimmers and are not warranted if used on dimmer systems. + + Excellent color rendition - up to 92 CRI + Heat resisting glass bulb + Click here for specific product and ordering information on this lamp. Information for this product last modified on June 22 2004. ©2004-2005 Koninklijke Philips Electronics N.V. All rights reserved. Privacy policy Philips. Access to and use of this Web Site is subject to these Terms of use. http://www.nam.lighting.philips.com/us/ecatalog/hid/displayhid.php?id=28 4/3/2005 T1 Metal Halide Lamp Ballast Catalog Number 71A5282 For 70W M98/M143 60 Hz HX-HPF Status: Active DIMENSIONS AND DATA 3 X 4 CORE - 2 COIL UNIT 5.10 " 4.50" 0.7" 1.0" A B MAX. 0.25" WIDE 2 SLOTS 3.95" 3.50" 4 HOLES CLEARED FOR #10 THRU-BOLTS 2.45" 2.80" Capacitor: 7C080L33-R 2.90" INPUT VOLTS 120 277 HX-HPF CIRCUIT TYPE 90% POWER FACTOR (min) REGULATION ±5% Line Volts ±7% Lamp Watts LINE CURRENT (Amps) Operating................................................... 0.80 0.35 Open Circuit............................................... 1.90 0.80 Starting...................................................... 0.55 0.25 UL TEMPERATURE RATINGS Insulation Class H(180°C) Coil Temperature Code A A 1029 MIN. AMBIENT STARTING TEMP. -20°F or -30°C NOM. OPEN CIRCUIT VOLTAGE 255 INPUT VOLTAGE AT LAMP DROPOUT........................... 90 208 INPUT WATTS 88 RECOMMENDED FUSE (Amps)..................................... 4 2 CORE and COIL Dimension (A) 1.45 Dimension (B) 2.75 Weight (lbs.) 5 Lead Lengths 12" CAPACITOR REQUIREMENT Microfarads 8.0 Volts (min.) 280 Fault Current Withstand (amps) 60 Hz TEST PROCEDURES (Refer to Advance Test Procedure for HID Ballasts - Form 1270) High Potential Test (Volts) 1 minute 2000 2 seconds 2500 Open Circuit Voltage Test (Volts) 230-280 Short-Circuit Current Test (Amps) Secondary Current 0.95-1.25 Input Current.............................................. 0.55 0.25 0.80 0.45 - - - Wiring Diagram: LAMP CAP LINE V LINE V X3 X1 IGNITOR CAP LAMP LINE V X2 COM LINE V Capacitance: Dia/Oval Dim: Height: Temp Rating: 8 1.25 2.9 105°C COM COM Fig. K Ordering Information Ignitor: LI533-H4 Order Suffix 500D. 510D. 600. 610. Description Ballast With Ignitor and Dry Film Capacitor Ballast w/Welded Bracket, Ignitor, & Dry Film Capacitor Ballast and Ignitor, No Capacitor Ballast with Welded Bracket and Ignitor, No Capacitor Ballast to Lamp Distance (BTL) = 15 feet Temp Rating: 105°C Data is based upon tests performed by Advance Transformer in a controlled environment and representitive of relative performance. Actual performance can vary depending on operating conditions. Specifications are subject to change without notice. ADVANCE TRANSFORMER CO. O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018 Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071 Corporate Offices: Phone: 800-322-2086 11/08/00 T3 JOB: __________________________ LOCATION: ____________________ CATALOG: DECORATIVE D9 SUPPLEMENT 2004/05 DATE: _________________________ PRODUCT SPECIFICATIONS STYLE # D9-2016 SERIES NAME: DAU SPOT 12” / 30.8 cm STRUCTURE: Metal COLOR /FINISH: Brushed Aluminum DIFFUSER: N/A 10” / 26 cm MATT WHITE FINISH LAMP TYPE: Halogen GZ10 MR20 MAX WATT: 2 x 75W DIMENSIONS: D. 12” x Ht. 10” APPROVALS: Approved by CSA for North American Standards. NOTES: _________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ ZANEEN LIGHTING 65 DENSLEY AVE. TORONTO, ONTARIO, CANADA M6M 2P5 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com zaneen@zaneen.com Luminaire Comparison Metal Halide Max/Min ratio for shadows: 2:1 Halogen Max/Min ratio for shadows: 6:1 Halogen Max/Min ratio for sparkle: 15:1 Metal Halide Max/Min ratio for sparkle: 2:1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 99 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:f5e9ff44-7041-483a-873c-49d22347b7ff Modify Date : 2005:04:06 15:57:41-04:00 Create Date : 2005:04:05 12:45:15-04:00 Metadata Date : 2005:04:06 15:57:41-04:00 Document ID : uuid:4676b4be-1d5f-4462-b396-ec0de85613c1 Format : application/pdf Creator : Adobe Acrobat 6.0 Producer : Adobe Acrobat 6.0EXIF Metadata provided by EXIF.tools