Panasonic Air Conditioner PDF C18KKS
CS-C18KKS to the manual a9f60c52-3533-4c54-b637-4039cf578b8a
User Manual: PDF Panasonic Service Manuals - Panasonic Middle East
Open the PDF directly: View PDF .
Page Count: 67
Download | ![]() |
Open PDF In Browser | View PDF |
Order No: PHAAM1006051C3 Indoor Unit CS-C18KKS CS-C24KKS Outdoor Unit CU-C18KKS CU-C24KKS WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the products dealt with in this service information by anyone else could result in serious injury or death. TABLE OF CONTENTS 1. Safety Precautions.............................................3 2. Specification .......................................................5 3. Features ..............................................................7 4. Location of Controls and Components ...........8 4.1 4.2 4.3 Indoor Unit....................................................8 Outdoor Unit .................................................8 Remote Control ............................................8 5. Dimensions .........................................................9 5.1 5.2 Indoor Unit....................................................9 Outdoor Unit ...............................................10 6. Refrigeration Cycle Diagram...........................11 7. Block Diagram ..................................................12 8. Wiring Connection Diagram............................13 8.1 8.2 CS-C18KKS CU-C18KKS ..........................13 CS-C24KKS CU-C24KKS ..........................14 9. Electronic Circuit Diagram ..............................15 9.1 9.2 CS-C18KKS CU-C18KKS ..........................15 CS-C24KKS CU-C24KKS ..........................16 10. Printed Circuit Board .......................................17 10.1 Indoor Unit..................................................17 11. Installation Instruction.....................................20 11.1 11.2 11.3 Select the Best Location ............................20 Indoor Unit..................................................21 Outdoor Unit ...............................................25 12. Operation Control.............................................29 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9 12.10 12.11 12.12 12.13 12.14 12.15 Cooling Operation ......................................29 Soft Dry Operation......................................30 Automatic Operation ..................................31 Indoor Fan Speed Control..........................32 Outdoor Fan Speed Control .......................34 Vertical Airflow Direction Control................34 Horizontal Airflow Direction Control ...........35 Powerful Operation.....................................35 Quiet Operation ..........................................36 Timer Control..............................................37 Random Auto Restart Control ....................37 Remote Control Signal Receiving Sound...37 Patrol Operation .........................................38 E-ion operation ...........................................42 ECO Patrol Operation ................................45 © Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law. 13. Protection Control............................................49 13.1 13.2 13.3 13.4 13.5 13.6 13.7 Restart Control (Time Delay Safety Control).. ....................................................................49 7 Minutes Time Save Control .....................49 60 Seconds Forced Operation ...................49 Starting Current Control .............................49 Freeze Prevention Control .........................50 Compressor Reverse Rotation Protection Control ........................................................50 Dew Prevention Control .............................50 14. Servicing Mode .................................................51 14.1 14.2 Auto OFF/ON Button ..................................51 Remote Control Button...............................52 15. Troubleshooting Guide....................................53 15.1 Refrigeration cycle system .........................53 16. Disassembly and Assembly Instructions ......55 16.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures .................................................55 17. Technical Data ..................................................59 17.1 Operation Characteristics...........................59 18. Exploded View and Replacement Parts List..63 18.1 18.2 Indoor Unit ..................................................63 Outdoor Unit ...............................................66 2 1. Safety Precautions • • • • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications. WARNING This indication shows the possibility of causing death or serious injury. CAUTION This indication shows the possibility of causing injury or damage to properties. The items to be followed are classified by the symbols: This symbol denotes item that is PROHIBITED from doing. • Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. WARNING 1. Do not modify the machine, part, material during repairing service. 2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 3. Do not wrench the fasten terminal. Pull it out or insert it straightly. 4. Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, electrical shock or fire. 5. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 6. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 7. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 8. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 9. This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 10. Do not use joint cable for indoor / outdoor connection cable. Use the specified Indoor/Outdoor connection cable, refer to installation instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection. 11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock. 12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.). 13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb up to outdoor unit and cross over the handrail and causing accident. 14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 16. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 17. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage. 18. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of compressor while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.) 19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc). 3 WARNING 20. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire. 21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 23. Must not use other parts except original parts described in catalog and manual. CAUTION 1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage. 4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 5. Select an installation location which is easy for maintenance. 6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. i. Power supply connection to the receptacle using a power plug. Use an approved 15/16A (3/4~1.5HP) or 16A (2.0HP) or 20A (2.5HP) or 25A (3.0HP) power plug with earth pin for the connection to the socket. ii. Power supply connection to a circuit breaker for the permanent component. Use an approved 16A (3/4~2.0HP) or 20A (2.5HP) or 25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap. 8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite. 9. Installation or servicing work: It may need two people to carry out the installation or servicing work. 10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 11. Do not sit or step on the unit, you may fall down accidentally. 12. Do not touch the sharp aluminum fins or edges of metal parts. If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury. 4 2. Specification Model Indoor CS-C18KKS CS-C24KKS Outdoor CU-C18KKS CU-C24KKS Performance Test Condition Power Supply Capacity SASO (T3) SASO (T1) Phase, Hz Single, 60 Single, 60 V 220 220 kW 4.40 5.10 5.60 6.50 BTU/h 15000 17400 19100 22200 3780 4390 4820 5590 A 9.1 7.8 13.9 11.9 Input Power W 1.96k 1.69k 3.00k 2.56k W/W 2.24 3.02 1.87 2.54 BTU/hW 7.65 10.30 6.35 8.65 % 98 98 98 98 dB-A 42 / 37 42 / 37 46 / 40 46 / 40 Power Level dB - - - - dB-A 56 / - 56 / - 57 / - 57 / - Power Level dB - - - - Cooling kcal/h EER Indoor Noise (H / L) Outdoor Noise (H / L) Max Current (A) / Max Input Power (W) 11.5 / 2.60k 16.8 / 3.70k Starting Current (A) 38.0 63.0 Hermetic Motor Hermetic Motor Rotary (2-poles) Rotary (2-poles) 1.2k 1.8k Type Cross-Flow Fan Cross-Flow Fan Material ASG30K1 ASG30K1 Type Compressor Motor Type Output Power W Motor Type Indoor Fan SASO (T3) Running Current Power Factor Transistor (8-poles) Transistor (8-poles) Input Power W - - Output Power W 40 40 rpm 930 960 QLo Speed Outdoor Fan SASO (T1) Lo rpm 1020 1110 Me rpm 1110 1230 Hi rpm 1200 1350 SHi rpm 1370 1500 Type Propeller Fan Propeller Fan Material PP Resin PP Resin Motor Type Induction (6 - poles) Induction (6 - poles) 138 135 Input Power W Output Power Speed W 86 79 Hi rpm 850 840 Lo rpm - 490 L/h (Pt/h) Moisture Removal QLo Indoor Airflow 1.3 (2.7) 3 12.2 (432) 12.9 (457) 3 3 13.4 (474) 15.0 (528) 3 3 14.6 (516) 16.6 (586) 3 3 15.8 (558) 18.2 (642) 3 3 18.0 (637) 20.2 (714) 3 3 54.0 (1910) 54.0 (1910) 3 3 - 31.5 (1110) m /min (ft /min) Lo m /min (ft /min) Me m /min (ft /min) Hi SHi Outdoor Airflow 0.7 (1.5) 3 m /min (ft /min) m /min (ft /min) Hi m /min (ft /min) Lo m /min (ft /min) 5 Control Device Refrigeration Cycle Dimension Piping Weight Capillary tube Capillary tube Refrigerant Oil cm ATMOS NM56M or SUNISO 4GDID (650) ATMOS M60 or SUNISO 4GDID (1130) Refrigerant Type g (oz) R22, 1.27k (44.8) R22, 1.61k (56.8) Height(I/D / O/D) mm (inch) 290 (11-7/16) 750 (29-17/32) 290 (11-7/16) 750 (29-17/32) Width (I/D / O/D) mm (inch) 1070 (42-5/32) 875 (34-15/32) 1070 (42-5/32) 875 (34-15/32) Depth (I/D / O/D) mm (inch) 235 (9-9/32) 345 (13-19/32) 235 (9-9/32) 345 (13-19/32) Net (I/D / O/D) kg (lb) 12.0 (26) 48.0 (106) 12.0 (26) 56.0 (123) 3 Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8) Standard length m (ft) 5.0 (16.4) 5.0 (16.4) Length range (min – max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0) I/D & O/D Height different m (ft) 20 (65.6) 20 (65.6) Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3) Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6) Inner Diameter mm 16 16 Length mm Drain Hose Indoor Heat Exchanger 650 650 Fin Material Pre Coat Pre Coat Fin Type Slit Fin Slit Fin Row x Stage x FPI 2 x 15 x 21 2 x 15 x 21 Size (W x H x L) Outdoor Heat Exchanger 810 x 315 x 25.4 810 x 315 x 25.4 Fin Material mm Blue Coated Blue Coated Fin Type Slit Fin Slit Fin Row x Stage x FPI 2 x 34 x 17 2 x 34 x 17 Size (W x H x L) 25.4 x 714 x 826.2:846.2 25.4 x 714 x 826.2:846.2 Material Polypropelene Polypropelene Type One-touch One-touch Indoor Indoor 16 20 Thermostat - Mechanical Protection Device - - Air Filter mm Power Supply Power Supply Cord Indoor Operation Range Outdoor Operation Range A Dry Bulb Wet Bulb Dry Bulb Wet Bulb Maximum 32 23 32 23 Minimum 16 11 16 11 Maximum 52 31 52 31 Minimum 16 11 16 11 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. 3. Specifications are subjected to change without prior notice for further improvement. Outdoor Dry Bulb temperature can be set up to 55°C with Indoor Dry Bulb temperature is 29°C. When humidity does not exceed 90% and room temperature is above 21°C. 6 3. Features • E-ion Air Purifying System with Patrol Sensor o Active e-ions are released to catch dust particles and bring them back the large positively charged filter. o Patrol Sensor color changes to indicate the dirt level in the air • Long Installation Piping o CS/CU-C18KK, CS/CU-C24KK, long piping up to 25 meters. • Easy to use remote control • Quality Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor o Noise prevention during soft dry operation o Blue coated condenser for high resistance to corrosion • Operation Improvement o Quiet mode to reduce the indoor unit operating sound o Powerful mode to reach the desired room temperature quickly o 24-hour timer setting 7 4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control 8 5. Dimensions 5.1 Indoor Unit 9 5.2 Outdoor Unit 10 6. Refrigeration Cycle Diagram INDOOR OUTDOOR LIQUID SIDE CAPILLARY TUBE STRAINER THERMOSTAT (C24KK only) 2-WAY VALVE INTAKE AIR TEMP. SENSOR PIPE TEMP. SENSOR HEAT EXCHANGER (CONDENSER) HEAT EXCHANGER (EVAPORATOR) GAS SIDE 3-WAY VALVE COMPRESSOR 11 7. Block Diagram 12 8. Wiring Connection Diagram 8.1 CS-C18KKS CU-C18KKS Resistance of Outdoor Fan Motor Windings MODEL CU-C18KKS CONNECTION CWA951401J BLUE-YELLOW 59.47Ω YELLOW-RED 60.95Ω Note: Resistance at 20°C of ambient temperature. Resistance of Compressor Windings MODEL CU-C18KKS CONNECTION 2KS252F5AA04 C-R 1.959Ω C-S 3.083Ω Note: Resistance at 20°C of ambient temperature. 13 8.2 CS-C24KKS CU-C24KKS Resistance of Outdoor Fan Motor Windings MODEL CU-C24KKS CONNECTION CWA951399J YELLOW-BLUE 59.47Ω YELLOW-ORANGE 80.58Ω YELLOW-RED 60.95Ω Note: Resistance at 20°C of ambient temperature. Resistance of Compressor Windings MODEL CU-C24KKS CONNECTION 2J39S236A1A C-R 0.933Ω C-S 1.584Ω Note: Resistance at 20°C of ambient temperature. 14 9. Electronic Circuit Diagram 9.1 CS-C18KKS CU-C18KKS 15 9.2 CS-C24KKS CU-C24KKS 16 10. Printed Circuit Board 10.1 Indoor Unit 10.1.1 Main Printed Circuit Board 17 10.1.2 Power Printed Circuit Board 18 10.1.3 Indicator Printed Circuit Board 10.1.4 Receiver Printed Circuit Board 10.1.5 High Voltage Power Supply Printed Circuit Board 19 11.1.3 11. Installation Instruction 11.1 Select the Best Location 11.1.1 • • • • • • • • • Do not install the unit in excessive oil fume area such as kitchen, workshop and etc. There should not be any heat source or steam near the unit. There should not be any obstacles blocking the air circulation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. Recommended installation height for indoor unit shall be at least 2.5 m. 11.1.2 • • • • • Indoor Unit Outdoor Unit If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed. There should not be any animal or plant which could be affected by hot air discharged. Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles. Do not place any obstacles which may cause a short circuit of the discharged air. If piping length is over the [piping length for additional gas], additional refrigerant should be added as shown in the table. Max. Min. Piping Std. Max. Horse Piping size Piping Piping Additional Length Model Power Length Elevation Length Length Refrigerant for add. (m) (g/m) (HP) Gas Liquid (m) (m) (m) gas (m) mm C18*** 2.0HP 12.7 (1/2") 6.35 mm mm (1/4") C24*** 2.5HP 15.88 (5/8") 5 20 3 25 20 7.5 20 3 25 30 7.5 Example: For C18*** If the unit is installed at 10 m distance, the quantity of additional refrigerant should be 50 g….(10-7.5) m x 20 g/m = 50 g. 20 Indoor/Outdoor Unit Installation Diagram 11.2 Indoor Unit 11.2.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent if from the vibration. The centre of installation plate should be at more than c at right and left of the wall. The distance from installation plate edge to ceiling should more than d. From installation plate left edge to unit’s left side is e. From installation plate right edge to unit’s right side is f. B ○ : For left side piping, piping connection for liquid should be about g from this line. : For left side piping, piping connection gas should be about h from this line. 1 2 11.2.2 1 2 3 Mount the installation plate on the wall with 5 screws or more (at least 5 screws). (If mounting the unit on the concrete wall, consider using anchor bolts.) o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. Drill the piping plate hole with ø70mm hole-core drill. o Putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 128 mm for left and right hole respectively. Another method is intersection point of arrow mark extension. The meeting point of the extension arrow mark is the hole center position. o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side. (refer to step 3) To Drill a Hole in the Wall and Install a Sleeve of Piping Insert the piping sleeve to the hole. Fix the busing to the sleeve. Cut the sleeve until it extrudes about 15mm from the wall. Caution When the wall is hollow, please be sure to use the sleeve for tube ass’y to prevent dangers caused by mice biting the connecting cable. 4 Finish by sealing the sleeve with putty or caulking compound at the final stage. 21 11.2.3 Indoor Unit Installation ! Caution Use shock absorber during pull out the piping to protect the intake grille from damage. ! Do not turn over the unit without it ’s shock absorber during pull out the piping. It may cause intake grille damage Piping Piping Shock absorber Intake grille 11.2.3.1 For the right rear piping 11.2.3.2 For the right and right bottom piping 11.2.3.3 For the embedded piping (This can be used for left rear piping and bottom piping also. 22 11.2.4 Connect the Cable to the Indoor Unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 2.5mm2 (2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. • • • Secure the connecting cable onto the control board with the holder. This equipment must be properly earthed. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason. 23 11.2.5 Wire Stripping And Connecting Requirement 11.2.5.1 1 2 3 Cutting and flaring the piping Please cut using pipe cutter and then remove the burrs. Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. Please make flare after inserting the flare nut onto the copper pipes. 24 11.3 Outdoor Unit 11.3.1 • Install the Outdoor Unit After selecting the best location, start installation to Indoor/Outdoor Unit Installation Diagram. 1 Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10mm). 2 When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails. B Model C18***, C24*** A 612.5 mm B 131 mm C 19 mm D 383 mm D C A 11.3.2 Connecting the Piping 11.3.2.1 Connecting the piping to indoor Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe. (In case of using long piping) Connect the piping • Align the center of piping and sufficiently tighten the flare nut with fingers. • Further tighten the flare nut with torque wrench in specified torque as stated in the table. 11.3.2.2 Connecting the piping to outdoor Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the flare nut (locate at valve) onto the copper pipe. Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table. CAUTION Do not overtighten, overtightening may cause gas leakage. Piping size Torque (6.35 mm) 1/4” [18 N•m (1.8 kgf.m)] (9.52 mm) 3/8” [42 N•m (4.3 kgf.m)] (12.7 mm) 1/2” [55 N•m (5.6 kgf.m)] (15.88 mm) 5/8” [65 N•m (6.6 kgf.m)] (19.05 mm) 3/4” [100 N•m (10.2 kgf.m)] Spanner or Wrench Torque wrench 25 11.3.3 Evacuation of the Equipment FOR ENVIRONMENTAL PROTECTION, MANUFACTURER STRONGLY RECOMMENDS TO USE EVACUATION METHOD. 1 2 3 4 5 6 7 8 Connect a charging hose with a push pin to the Low side of a charging set and the service port of the 3-way valve. o Be sure to connect the end of the charging hose with the push pin to the service port. Connect the center hose of the charging set to a vacuum pump. Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 cmHg (0 MPa) to -76 cmHg (-0.1 MPa). Then evacuate the air approximately ten minutes. Close the Low side valve of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not move after approximately five minutes. Note: BE SURE TO TAKE THIS PROCEDURE IN ORDER TO AVOID REFRIGERENT GAS LEAKAGE. Disconnect the charging hose from the vacuum pump and from the service port of the 3-way valve. Tighten the service port caps of the 3-way valve at a torque of 18 N•m with a torque wrench. Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to “OPEN” using a hexagonal wrench (4 mm). Mount valve caps onto the 2-way valve and the 3-way valve. o Be sure to check for gas leakage. CAUTION • - If gauge needle does not move from 0 cmHg (0 MPa) to -76 cmHg (-01 MPa), in the step e above take the following measure: If the leak stops when the piping connections are tightened further, continue working from step e. If the leak does not stop when the connections are retightened, repair location of leak. Do not release refrigerant during piping work for installation and reinstallation. Take care of the liquid refrigerant, it may cause frostbite. 26 11.3.4 Air Purging of the Piping and Indoor The remaining air in the Refrigerant cycle which contains moisture may cause malfunction on the compressor. 1 Remove the caps from the 2-way and 3-way valves. 2 Remove the service-port cap from the 3-way valves. 3 To open the valve, turn the valve stem of 2-way valve counter-clockwise approx. 90° and hold it there for ten seconds, then close it. 4 Check gas-leakage of the connecting portion of the pipings. o For the left piping, refer to 4 (A). 11.3.5 1 2 Connect the cable to the Outdoor Unit Remove the control board cover from the unit by loosening the screw. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 2.5mm2 (2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. 3 • Secure the cable onto the control board with the holder. 4 Attach the control board cover back to the original position with the screw. 5 For wire stripping and connection requirement, refer to instruction g of the indoor unit. This equipment must be properly earthed. Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason. 27 11.3.6 1 2 Pipe Insulation Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap the insulated piping end to prevent water from going inside the piping. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E-FOAM with thickness 6mm or above. 28 12. Operation Control 12.1 Cooling Operation • • • • Cooling operation can be set using remote control. This operation is applied to cool down the room temperature to the setting temperature set on the remote control. The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. During cooling operation, the compressor will stop and restart as shown in figure below: 12.1.1 Cooling Operation Time Diagram 29 12.2 Soft Dry Operation • • • • • Soft Dry operation can be set using remote control. Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room. This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control. When operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turn “OFF” for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown in figure below. However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point. 12.2.1 Soft Dry Operation Time Diagram 30 12.3 Automatic Operation • • • Automatic operation can be set using remote control. This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature. After judged the temperature, the operation mode is determined by referring to the below standard. ↑ 23°C ↓ Intake Air Temperature • Setting Temperature (Standard) 25°C 22°C The setting temperature for all the operations can be changed one level up or one level down from the standard temperature as shown in table below by pressing the temperature up or temperature down button at remote control. Higher Standard Lower • Soft Dry Operation Then, the unit starts to operate at determined operation mode, until it is switched off using remote control, with the setting temperature as shown in table below. Cooling Operation Soft Dry Operation • Cooling Operation Æ Æ Æ +2°C ±0°C -2°C Cooling 27°C 25°C 23°C Soft Dry 24°C 22°C 20°C The operation mode judging temperature and standard setting temperature can be increased by 2°C permanently, by open the circuit of JX03 at indoor unit’s printed circuit board. Setting Temperature (Standard) Intake Air Temperature ↑ 25°C ↓ Cooling Operation Cooling Operation 27°C Soft Dry Operation Soft Dry Operation 24°C 31 12.4 Indoor Fan Speed Control • Indoor fan speed can be set using remote control. 12.4.1 Fan Speed Rotation Chart Fan Speed (rpm) Speed CS-C18KKS 1370 1200 1110 1080 1020 850 670 1110 1020 930 Shi Hi Me HLo CLo LoSLo Qhi QMe QLo 12.4.2 • CS-C24KKS 1500 1350 1230 1190 1110 970 750 1150 1050 960 Automatic Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. o Fan speed rotates in the range of Hi, Me and Lo-. o Deodorizing Control will be activated. SHi Cooling Normal Quiet Normal Quiet Manual Me HLo CLo Lo- SLo Stop o o Hi-90 QHi QMe QLo Auto Manual Auto Manual Auto Manual Auto Hi o o Auto Powerful Soft Dry Manual Hi Me Lo o o o o o o o o o o o o o Me-90 CLo-90 Hi-100 Me-100 o o 32 • Auto Fan Speed during cooling operation: 1 Indoor fan will rotate alternately between off and on as shown in below diagram. 2 At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing purpose. 3 For the first time the compressor operates, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the start of compressor. This cause the room temperature to achieve the setting temperature quickly. 4 During compressor stops, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher volume of refrigerant in liquid form returning to the compressor. 5 After the compressor turned off for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the room. This is to obtain the actual reading of the intake air temperature. 6 For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and lesser noise environment, after 70 seconds from the restarts of compressor. • Auto Fan Speed during Soft Dry operation. 1 Indoor fan will rotate alternately between off and Lo-. 2 At the beginning of each compressor starts operation, indoor fan will increase fan speed gradually for deodorizing purpose. 3 When compressor turned off for 6 minutes, indoor fan will start at Lo- to circulate the air in the room. This is to obtain the actual reading of intake air temperature. 12.4.3 • • Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control. There are 3 types of fan speed settings: Lo, Me, Hi. 12.4.4 • • Manual Fan Speed Control Indoor Fan Motor rpm Abnormal Control Immediate after the fan motor is started, rpm abnormal control is performed every second. During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continuously for 10 seconds, the fan motor error counter increased; fan motor is then stopped and restarted. If the fan motor error counter increased to 7, then air conditioner will stop operation. 33 12.5 Outdoor Fan Speed Control • • • • • There is only one speed for outdoor fan motor. (Applicable for CU-C18KK) There is 2 speeds for outdoor fan motor. Outdoor fan speed can be changed to Hi or Lo according to outdoor temperature. (Applicable for CU-C24KK). For Cooling and Soft Dry operation, when outdoor temperature reaches to 31°C (Hi-speed), 29°C (Lo-speed). (Applicable for CU-C24KK). When air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously. Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off. 12.6 Vertical Airflow Direction Control 12.6.1 • • • Auto Control When the vertical airflow direction is set to Auto using the remote control, the louver swings up and down as shown in the diagram. When stops operation using the remote control, the discharge vent is reset and stops at the closing position. During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the louver will stop swinging. Horizontal Upper limit/0° Closing position / 148° Upper limit for cooling mode and soft dry mode/17° 28° Swing up and down Lower limit for cooling mode and soft dry mode/45° 12.6.2 • • • Manual Control When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow direction louver move up and down in the range shown in the diagram. The louver can be adjusted by pressing the button to the desired louver position. When stop operation using the remote control, the discharge vent is reset, and stop at the closing position. Horizontal Upper limit / 0° 17° Upper limit for cooling mode and soft dry mode Closing position / 148° 22° 28° 33° 39° 34 Lower limit for cooling mode and soft dry mode 12.7 Horizontal Airflow Direction Control 12.7.1 • • • When the horizontal airflow is set to Auto using the remote control, the vanes swings left and right as shown in the diagram. When stopped with remote control, the discharge vanes are reset and stop at the reset position. During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the vane will stop swinging and rest at 22° angle. 12.7.2 • • • Auto Control Manual Control When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow direction vane move left and right in the range shown in the diagram. The louver can be adjusted by pressing the button to the desired vane position. When stopped with remote control, the vanes is reset and stopped at reset position. 12.8 Powerful Operation • • • • • To achieve the setting temperature quickly. When powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present setting temperature (Lower temperature limit: 16°C). This operation automatically running under Shi fan speed (Cooling). Vertical Airflow Direction: o In “Manual” setting, the vane will automatically shift down 10° lower than previous setting. o In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward. Powerful operation stops when: o Quiet/Powerful button is pressed again o Powerful operation has operate for 15 minutes o Stopped by OFF/ON operation button. o Timer OFF activates o Operation mode is changed 35 12.9 Quiet Operation (For Cooling Operation or cooling region of Soft Dry Operation) • To provide quiet cooling operation condition. • Once the Quiet Operation is set at the remote control, the Quiet LED illuminated. The sound level will reduce around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound level. • Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only 1 hour 30 minutes (1 hour QLo, 30 minutes QLo + 50 rpm). • Manual Airflow Direction: o RPM control during Lo cool o RPM control during Hi & Me cool • Auto Fan Speed • Quiet operation stops when: o Quiet button is pressed again. o Stopped by OFF/ON operation button. o Timer OFF activates. o Operation mode button is changed. o Powerful button is pressed. 36 12.10 Timer Control 12.10.1 ON Timer • • • When the ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that the room will reach nearly to the set temperature by the set time. For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time. For Automatic operation, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect the intake air temperature to determine the operation mode. The power LED will blink. 12.10.2 OFF Timer • When the OFF Timer is set using the remote control, the unit will stop operate according to the desired setting. Notes: 1 By pressing ON/OFF operation button, the ON Timer or OFF Timer will not be cancel. 2 To cancel the previous timer setting, press CANCEL button. 3 To activate the previous timer setting, press SET button. 4 If main power supply is switched off, the Timer setting will be cancel. 12.11 • • • • If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is resumed. It will start with previous operation mode and airflow direction. If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be decided randomly using 4 parameters:- intake air temperature, fan speed and air swing louver position. This Random Auto Restart Control is not available when Timer is set. 12.12 • • Random Auto Restart Control Remote Control Signal Receiving Sound Short beep sound will be heard when turn ON the air conditioner or enabling other operations. Long beep sound will be heard when turn OFF the air conditioner or disabling other operations. 37 12.13 Patrol Operation • To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation • Patrol operation starts condition o When the unit operation is started with “OFF/ON” button o When the unit stops, “Patrol” operation is selected, Patrol individual operation will start. o During cooling only operation, “Patrol” operation is selected. • Patrol operation stops condition (when any of the following condition is fulfilled): o When “OFF/ON” button is selected. o During any operation with Patrol, “PATROL/e-ion” button is pressed. o When OFF Timer activates. • To disable the Patrol Operation during unit starts (default) with “OFF/ON” button o Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal setting mode. o Press “Timer Decrement" button to select “Pt dFLt”. o Press “Timer Set” button to toggle Patrol operation default OFF/ON. Long "beep": Turn OFF Patrol operation default. Short "beep": Turn ON Patrol operation default. SET Press continously for 15s SET Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit Patrol demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit ECO demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit check code (Buzzer:Short Beep) 38 Patrol Sensor Control o First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is monitored. The Air Dirtiness level is set to Clean, Patrol LED turns blue color. o After that, Patrol sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air. o The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value from time to time to get the Air Dirtiness Value. o There are 3 air dirtiness level, based on the Air Dirtiness Value: Air Dirtiness level 0: Clean – Patrol LED = blue color Air Dirtiness level 1: Moderate – Patrol LED = orange color Air Dirtiness level 2: Contaminated – Patrol LED = red color Moderate Air Quality Worsen Air Dirtiness Level 0 G1 G3 Air Dirtiness Level 1 G2 G4 Air Dirtiness Level 2 Air Quality Improve Dirty Air Dirtiness Value Clean • • Dirtiness level sensitivity adjustment It is possible to change the Patrol sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly: 1 Press and release “SET” button. 2 Press Timer ▲ / Timer ▼ button to select sensitivity. (Air 1 “Low Sensitivity” ↔ Air 2 “Standard” (Default) ↔ Air 3 “High Sensitivity”) 3 Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds. 4 LCD returned to original display if remote control does not operate for 30 seconds • e-ion Control o e-ion operation starts condition When dirtiness at level 2 (Patrol LED turns red). 2 minutes after stabilization time (Patrol LED turns red). 4 hours at level 0 (Patrol LED turns red). o e-ion operation time If dirtiness level improves from level 2 to level 1 (Patrol LED from red to orange), the unit carries out level change after 60 seconds. When dirtiness level returns to level 0 (Patrol LED turns blue) continuously for 11 minutes or more, e-ion operation stops. • Dirtiness Level and fan speed o When e-ion operation starts, the fan speed increases based on dirtiness level: Dirtiness level e-ion ON o Dirtiness level 0 Dirtiness level 1 Dirtiness level 2 Patrol individual operation No change Me Me rpm shift Combine operation Auto Manual No change No change + 20 +1 fan tap (max - Hi) + 40 +2 fan tap (max - Hi) Indoor Fan Control During any operation mode combines with Patrol operation, fan speed follows respective operation mode. During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is allowed. Even if “Fan Speed” button is pressed, no signal is sent to air conditioner, and no change on LCD display. During Patrol individual operation if e-ion stops, Indoor Fan stop operation. 39 • Airflow direction (Horizontal, Vertical) Control o During any operation mode combines with Patrol operation, airflow direction follows respective operation mode. o During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no signal is sent to air conditioner, and no change on LCD display. o During Patrol individual operation if e-ion stops, Airflow direction louver closed. • LED display (Applicable to all models except KKD models) o When Patrol operation is selected, Patrol LED illuminates. o During Patrol individual operation, only Patrol LED illuminates. When e-ion air purifying operation starts based on dirtiness level, Power LED, Patrol LED and e-ion LED illuminates. PATROL LED No BLUE ORANGE RED TIMER BLUE ORANGE 1 When patrol function is not selected OFF OFF OFF - - 2 During gas sensor error detection control OFF OFF Blinking OFF OFF 3 During E-ion abnormal discharge error OFF OFF OFF Blinking OFF 4 During E-ion breakdown error OFF OFF OFF Blinking Blinking 5 During Test Mode OFF OFF OFF OFF OFF 6 During stop OFF OFF OFF OFF OFF 7 2 minutes gas sensor initial stabilization time (Level 0) ON OFF OFF OFF OFF a. Dirtiness level 0* ON OFF OFF OFF OFF b. Dirtiness level 1 OFF ON OFF OFF OFF c. Dirtiness level 1* OFF ON OFF ON OFF d. Dirtiness level 2 OFF OFF ON ON OFF 8 • Description E-ION During operation During patrol Remote Control Receiving Sound o Normal Operation Î Patrol Mode o Patrol Mode Î Stop o Patrol Mode Î Normal Operation o Stop Î Patrol : Beep : Long Beep : Beep : Beep • Timer Control o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol operation status. o When ON timer activates during any operation, no change and carry on current operation. o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is saved. • Power Failure Control o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes immediately. o During combination operation, if power failure occurs, after power resumes combination operation resume immediately. 40 • Patrol Operation Demo Mode o Patrol Operation Demo Mode start condition Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal setting mode. Press “Timer Decrement" button to select “Pt demo”. Press “Timer Set” button to toggle Patrol operation demo mode. • Long "beep": Turn OFF Patrol operation demo mode. • Short "beep": Turn ON Patrol operation demo mode. SET Press continously for 15s SET Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit Patrol demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit ECO demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit check code (Buzzer:Short Beep) o The Patrol indicator change color every 10 seconds follows the pattern below for demo purpose: BLUE o o (10 seconds) (10 seconds) ORANGE (10 seconds) (10 seconds) RED (10 seconds) During demo, all operation stops, remote control buttons and auto OFF/ON button are ignored. Patrol Operation Demo Mode stop condition Power supply reset. 41 12.14 E-ion operation • This operation provides clean air by producing negative ions to attract dust captured at the positively charged active e-ion filters. • e-ion operation start condition o During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation mode + e-ion operation) starts. o During unit is OFF, if “e-ion” operation is selected, e-ion individual operation starts. • e-ion operation stop condition o When “OFF/ON” button is pressed to stop the operation. o When “PATROL/e-ion” button is pressed. o When OFF Timer activates. • e-ion operation pause condition o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts. o When indoor intake temperature ≥ 40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30 minutes. • Indoor fan control o During any operation mode combines with e-ion operation, fan speed follows respective operation mode. o During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display. Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation. • Airflow direction control o During any operation mode combines with e-ion operation, airflow direction follows respective operation mode. o During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no signal is sent to air conditioner, and no change on LCD display. • Timer control o When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion operation status. o When ON timer activates during any operation, no change and carry on current operation. o When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is saved. • Indicator o When e-ion operation starts, e-ion indicator ON. • Remote Control Receiving Sound o Normal Operation o e-ion Operation o Stop o e-ion individual Operation • Î e-ion Operation Î Normal Operation Î e-ion individual Operation Î Stop : Beep : Beep : Beep : Long Beep Power failure o During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation resumes immediately. o During combination operation, if power failure occurs, after power resumes, combination operation resume immediately. o e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air conditioner operates without e-ion operation. 42 • e-ion Check Mode o e-ion abnormality check mode o Purpose is to improve sensor serviceability when sensor is malfunction. (1) Control starting condition When all of the conditions are formed Not in Patrol Demo mode. e-ion operation ON. When e-ion check mode signal is received; the procedure of selection is as shown: • Press “Set” button continuously for 15 seconds by using pointer to enter internal setting mode. • Press “Timer Decrement" button to select “CHC”. • Confirm setting by pressing “Timer Set” button, a “beep” sound will be heard. SET Press continously for 15s SET Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit Patrol demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit ECO demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit check code (Buzzer:Short Beep) o If abnormal discharge is detected at filter (short-circuited) due to water or dust adhesion, etc., the e-ion indicator blinks immediately. 43 • Error Detection Control When e-ion indicator blink, it indicates error listed below: o Active e-ion Air Purifying system PCB main connector open: Judgment Method • During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main connector to PCB is opened. o o Troubleshooting Methods • Connect the connector or stop operation (include during Patrol operation) to cancel the blinking. Abnormal Discharge error: Judgment Method • During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal discharge and stops power supplies to the Active e-ion Air Purifying system. • Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to water or dust adhesion, and so forth. • When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air Purifying system. • When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for e-ion Check Mode, where the error will shows immediately despite the 24 times counter) Troubleshooting Method • Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation and check the Active e-ion Air Purifying system main connector to PCB. • After that, press “e-ion” button again to confirm the e-ion indicator not blinking. • The 24 times counter will be clear after 10 minutes of normal operation or when operation stops. Error Reset Method • Press “OFF/ON” button to OFF the operation. • Press AUTO OFF/ON button at indoor unit to OFF the operation. • OFF Timer activates • Power supply reset Active e-ion Air Purifying system breakdown error: Judgment Method • When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, Active e-ion Air Purifying system breakdown error shows immediately. • It is due to indoor PCB or filter’s high voltage power supply damage. • Operations except e-ion continue. Both Timer indicator and e-ion indicator blink. Troubleshooting Method • Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation. • Change main circuit board or filter’s high voltage power supply. • When lo-feedback voltage supplied to Active e-ion Air Purifying system during e-ion operation, e-ion indicator and Timer indicator stop blinking. 44 12.15 ECO Patrol Operation • A Pyoelectric infrared sensor is used to detect injection strength variation of infrared at setting area to determine the presence or absence of human and its activity level. Human detection area is shown in figure below: • ECO Patrol operation – Human presence/absence detection outlined flow Process infrared sensor output signal Human detection (movement) every 3 seconds. ▼ Human detection records Records human detection (movement) result for 30 seconds and determine its activity level i.e. Hi/Lo. ▼ Presence / absence detection Compares current and previous human detection result every 30 seconds to determine the presence or absence of human. ▼ Presence / absence determination Based on human presence / absence detection, if human presence detection showed within 30 minutes, it is recognised that human is present. If human absence detection showed continuously for more than 30 minutes, it is recognised that no human is present. • ECO Patrol Sensor abnormality detection (1) Connnector pulled out (disconnected), Wire cut Abnormality (Fix Output at Hi) c Abnormal judgment start condition. Start from ECO Patrol Sensor power ON, and end after 30 seconds. d Control content. Judge ECO Patrol Sensor power level every 100ms. e Abnormal Judgment condition. When ECO Patrol Sensor has continues for 25 seconds Hi level. (2) Circuit Abnormal (Fix Output Lo) c Abnormal judgment start condition. After ECO Patrol Sensor unit power ON, and after pressed 70 seconds. d Control content. Judge ECO Patrol Sensor power level every 100ms. e Abnormal Judgment condition. When ECO Patrol Sensor has continues at Lo level for 25 seconds. (3) Abnormal treatment Any one of the above self-diagnosis result is abnormal • Abnormal counter +1 and ECO Patrol Sensor power supply OFF. • After ECO Patrol Sensor unit power is OFF for 5 seconds, Retry the ECO Patrol operation. • When Abnormal counter reach 4 counts, ECO Patrol sensor abnormality is confirmed. (Abnormal counter is cleared when sensor power ON and maintain normal for 120 seconds and above or Clear Anormal counter by power reset) • • • • Save ECO Patrol Sensor Abnormality (no Timer LED blinking). ECO Patrol Sensor operation OFF, but ECO Patrol LED maintain ON. The unit still operate as normal. Sensor error counter can be cleared only after power supply reset or AC Reset button on the remote control is pressed. 45 • ECO Patrol Demo Mode Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal setting mode. Press “Timer Decrement" button to select “EC demo”. Press “Timer Set” button to toggle ECO Patrol Demo mode. • Short "beep": Turn ON ECO Patrol Demo mode. • Long "beep": Turn OFF ECO Patrol Demo mode. SET Press continously for 15s SET Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit Patrol demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit ECO demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit check code (Buzzer:Short Beep) Control details: • During ECO Patrol Demo mode, operation LED ON and horizontal vane will set to Auto Swing. • When Hi activity judge, Fan speed change to Hi Fan and ECO Patrol LED ON. • When Lo activity judge, Fan speed change to Lo Fan and ECO Patrol LED OFF. • No setting temperature adjustment. 46 • During ECO Patrol operation, the internal setting temperature and fan speed are adjusted in order to provide comfort and energy saving. • ECO Patrol Start condition. Press ECO Patrol button to select ECO1 and ECO2. • ECO Patrol Stop condition. Press ECO Patrol button again. OFF Timer activates. Press OFF/ON button to turn off the air conditioner. Press AUTO OFF/ON button to turn off the air conditioner. Press POWERFUL/QUIET button. • ECO Patrol operation could ON when any of the following conditions is fulfilled: During forced cooling or forced heating operation. During e-ion or individual patrol operation. • Power Failure ECO Patrol operation will be resuming after recovered from power failure. • Timer Operation When unit is turn on by ON Timer and ECO Patrol operation is ON during previous operation before OFF, ECO Patrol operation will not be ON automatically. When unit is turn on by ON Timer and ECO Patrol operation is OFF during previous operation before OFF, ECO Patrol operation will not be ON automatically. • Other Information ECO Patrol, Powerful and Quiet cannot be operated at the same time. ECO Patrol sensor initialized time is 70 seconds from power supplied to ECO Patrol sensor, or 70 seconds from the operation start. • ECO 1 Operation Activity Level Low High None +2 oC Set Temperature Fan Speed • -1 oC Set Speed +1tap Up Med Fan Set Speed ECO 2 Operation Activity Level Low High None +3 oC Set Temperature Fan Speed -1 oC Set Speed +1tap Up Set Speed Med Fan 47 • • ECO Patrol Sensor abnormality check mode Purpose is to improve sensor serviceability when sensor is malfunction. (1) Control starting condition When all of the conditions are formed Not in ECO Patrol Demo mode. ECO Patrol mode ON. When ECO Patrol sensor check mode signal is received; the procedure of selection is as shown: • Press “Set” button continuously for 15 seconds by using pointer to enter internal setting mode. • Press “Timer Decrement" button to select “CHC”. • Confirm setting by pressing “Timer Set” button, a “beep” sound will be heard. SET Press continously for 15s SET Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit Patrol demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit ECO demo code (Buzzer: OFF:Long Beep, ON:Short Beep) SET Transmit check code (Buzzer:Short Beep) (2) Control ending condition. When any of the conditions are formed Operation stops. “Timer Cancel” button pressed. When ECO Patrol sensor check mode signal is not received for more than 30 seconds. (3) Control content. During ECO Patrol mode ON, when check signal is received, if (1) or (2) is detected. ECO Patrol LED start blinking (ECO Patrol sensor operation stops but the unit operates as normal) and ECO Patrol sensor abnormal code is memorized (the 4 times counter is ignored) The blinking of ECO Patrol LED can be cancelled by pressing ECO Patrol button again. Sensor error counter can be cleared only after power supply reset or “AC Reset” button on remote control is pressed. However, if there is no ECO Patrol sensor abnormally happen, ECO Patrol sensor operation will continues as normal. 48 13. Protection Control 13.1 Restart Control (Time Delay Safety Control) • • • When the thermo-off temperature (temperature which compressor stops to operate) is reach during:o Cooling operation – the compressor stops for 3 minutes (minimum) before resume operation. o Soft Dry operation – the compressor stops for 6 minutes (minimum) before resume operation. If the operation is stopped by the remote control, the compressor will not turn on within 3 minutes from the moment operation stop, although the unit is turn on again within the period. This phenomenon is to balance the pressure inside the refrigerant cycle. 13.2 7 Minutes Time Save Control • • The compressor will start automatically if it has stopped for 7 minutes and the intake air temperature falls between the compressor ON temperature (A) and compressor OFF temperature (B) during the period. This phenomenon is to reduce the built up humidity inside a room. 13.3 60 Seconds Forced Operation • • Once the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake air temperature has reached the thermo-off temperature. However, forced stop by pressing the OFF/ON operation button at the remote control is permitted. The reason for the compressor to force operate at the minimum 60 seconds is to allow the refrigerant oil run in a full cycle and return back to the outdoor unit. 13.4 Starting Current Control • • When the compressor, outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will start to operate at 1.6 seconds later. The reason of the difference is to reduce the starting current flow. 49 13.5 Freeze Prevention Control • • To protect indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form return to compressor. This control will activate when temperature of indoor heat exchanger falls below 2°C continuously for more than 4 minutes and compressor turn off. Indoor Heat Exchanger Temperature (°C) 10 Recovery 4 min 2 Compressor OFF • • Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery). Restart control (Time Delay Safety Control) will be applied in this control if the recovery time is too short. 13.6 Compressor Reverse Rotation Protection Control • • If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor heat exchanger is 2.5°C or less for continuously 2 minutes, compressor will stop and restart automatically. Time Delay Safety Control is activated before the compressor restart. Compressor starts for ≥ 5 minutes ▲T ≤ 2.5°C for 2 minutes Compressor OFF Compressor restart ▲ T = Intake air temperature – Indoor heat exchanger temperature • • • This is to prevent compressor from rotate reversely when there is an instantaneous power failure. If this condition happens continuously for 5 times within 50 minutes, unit will turn OFF with TIMER LED blinks. The 5 Times counter can be reset when either one of the following condition happen: o Unit is OFF by remote control or AUTO OFF/ON button. o Indoor intake temperature – Indoor piping temperature > 5°C for one minute or more. o Operation mode change. • The unit could be ON by pressing OFF/ON button at remote control but the TIMER LED will continue blinking. • TIMER LED blinking will be reset if: o Indoor intake temperature – Indoor piping temperature > 5°C for one minute or more. o Power supply reset. 13.7 Dew Prevention Control • • • • To prevent dew formation at indoor unit discharge area. This control starts if: o Cooling mode or Quiet mode is activated. o Remote Control setting temperature is less than 25°C. o Fan speed is at CLo or QLo. o Room temperature is constant (±1°C) for 30 minutes. o Compressor is continuously running. Fan speed will be adjusted accordingly in this control. o Fan sped will be increased slowly if the unit is in quiet mode and Lo fan speed. Dew prevention stop condition. o Remote control setting temperature is more than 25°C. o Fan speed is not at Lo or QLo. o Select Powerful operation. 50 14. Servicing Mode 14.1 Auto OFF/ON Button Auto OFF/ON Button Pressed Auto OFF/ON Button Pressed 5 sec Auto Operation Auto OFF/ON Button Pressed 5 sec Test Run Operation (Forced Cooling Operation) Stop Various Setting Mode Stop 1 AUTO OPERATION MODE The Auto Operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to operate air conditioner with limited function if remote control is misplaced or malfunction. 2 TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE) The Test Run Operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A “beep” sound will be heard at the fifth seconds, in order to identify the starting of this operation. 3 VARIOUS SETTING MODE The Various Setting Mode will be activated if (within 20 seconds of Test Run Operation) the Auto OFF/ON button is pressed for more than 5 seconds. 2 “beep” sounds will be heard to identify the starting of this operation. Under Various Setting Mode, user could perform the following operation: i. Press Auto OFF/ON button to toggle remote control receiving sound. - Short “beep”: Turn ON remote control receiving sound. - Long “beep”: Turn OFF remote control receiving sound. J_A After Auto OFF/ON button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON Mode is restarted. ii. Remote Control Number Switch. - There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit will only operate when received signal with same transmission code from remote control. This could prevent signal interference when there are 2 or more indoor units installed nearby together. - To change remote control transmission code, short or open jumpers at the remote control printed circuit board. J_B J-A J-B Remote Control Printed Circuit Board Jumper A (J-A) Jumper B (J-B) Remote Control No. Short Open A (Default) Open Open B Short Short C Open Short D - During Various Setting Mode, press any button at remote control to transmit and store the desired transmission code to the EEPROM. - After signal is received, the Various Setting Mode is cancelled and return to normal operation. - If there is no code is transmitted of Auto OFF/ON button is not pressed within 20 seconds, the Various Setting Mode will be cancelled. 51 14.2 Remote Control Button 14.2.1 • • To check current remote control transmission code and store the transmission code to EEPROM: o Press “Set” button for more than 10 seconds o Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code change. To change the air quality sensor: o Press and release by using pointer o Press the Timer Decrement button to select sensitivity: 1. Low sensitivity 2. Standard (Default) 3. Hi sensitivity o Confirm setting by pressing Timer Set button, a “beep” sound will be heard. LCD returns to original display after 2 seconds. o LCD returns to original display if remote control does not operate for 30 seconds. 14.2.2 • TIMER ▲ To change indoor unit indicators’ intensity: o Press continuously for 5 seconds. 14.2.5 • RESET (RC) Button To clear and restore the remote control setting to factory default. o Press once to clear the memory 14.2.4 • CLOCK Button To change the remote control time format: o Press for more than 5 seconds 14.2.3 • SET Button TIMER ▼ To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F) o Press continuously for 10 seconds. 52 15. Troubleshooting Guide 15.1 Refrigeration cycle system In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right. Different in the intake and outlet air temperatures Normal Pressure and Outlet Air Temperature (Standard) Outlet air Gas Pressure Temperature Mpa 2 (°C) (kg/cm G) Cooling Mode 0.4 ~ 0.6 (4 ~ 6) 12 ~ 16 Condition: Indoor fan speed = High Outdoor temperature = 35°C Normal • Measuring the air temperature different • Measuring electric current during operation • Measuring gas side pressure More than 8°C (15 minutes after an operation is started) Less than 8°C at the cooling mode Value of electric current during operation Higher than specified Dusty condenser preventing heat radiation Excessive amount of refrigerant Lower than specified Gas side pressure Cooling Mode High Low Low Inefficient compressor Insufficient refrigerant Clogged strainer or capillary cube 53 15.1.1 Relationship between the condition of the air conditioner and pressure and electric current Condition of the air conditioner Cooling Mode Low Pressure High Pressure Electric current during operation Insufficient refrigerant (gas leakage) Ô Ô Ô Clogged capillary tube or strainer Ô Ô Ô Short circuit in the indoor unit Ô Ô Ô Heat radiation deficiency of the outdoor unit Ò Ò Ò Inefficient compression Ò Ô Ô • Carry out the measurement of pressure, electric current, and temperature fifteen minutes after an operation is started. 15.1.2 Diagnosis methods of a malfunction of a compressor Nature of fault Symptom • Electric current during operation becomes approximately 20% lower than the normal value. Insufficient compressing of a compressor • The discharge tube of the compressor becomes abnormally hot (normally 70°C to 90°C). • The different between high pressure and low pressure becomes almost zero. Locked compressor • Electric current reaches a high level abnormally, and the value exceeds the limit of an ammeter. In some cases, a breaker turns off. • The compressor has a humming sound. 54 16. Disassembly and Assembly Instructions WARNING High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 16.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 16.1.1 To remove front grille Figure 1 16.1.2 To remove horizontal vane Figure 2 55 16.1.3 To remove power electronic controller Figure 3 Figure 4 Figure 5 Figure 6 56 16.1.4 To remove discharge grille Figure 7 16.1.5 To remove control board Figure 8 16.1.6 To remove cross flow fan and indoor fan motor Figure 9 57 Figure 10 Figure 11 Figure 12 58 17. Technical Data 17.1 Operation Characteristics 17.1.1 Cooling Characteristic o Room temperature: o Operation condition: o Piping length: 27°C (DBT), 19°C (WBT) High fan speed 5.0m Current (A) 220V 11.00 10.50 10.00 9.50 9.00 8.50 8.00 7.50 7.00 30 35 40 45 Outdoor Temperature (ºC) 50 55 Gas Side Piping Pressure (MPa) 220V 0.620 0.590 0.560 0.530 0.500 0.470 30 35 40 45 Outdoor Temperature (ºC) 50 55 220V Capacity (kW) 5.60 5.30 5.00 4.70 4.40 4.10 3.80 30 35 40 45 Outdoor Temperature (ºC) 50 55 220V 16.6 Outlet Air (ºC) • CS-C18KKS CU-C18KKS 16.1 15.6 15.1 14.6 14.1 30 35 40 45 Outdoor Temperature (ºC) 59 50 55 Piping Length Characteristic o Outdoor temperature: 35°C (DBT), 24°C (WBT) o Operation condition: High fan speed o Piping length: 5.0m Current (A) 220V 7.90 7.80 7.70 7.60 7.50 7.40 7.30 7.20 3 5 7 9 11 13 15 17 Piping Length (m) 19 21 23 25 Gas Side Piping Pressure (MPa) 220V 0.500 0.490 0.480 0.470 0.460 0.450 0.440 0.430 3 5 7 9 11 13 15 17 Piping Length (m) 19 21 23 25 Capacity (kW) 220V 5.20 5.10 5.00 4.90 4.80 4.70 4.60 4.50 3 5 7 9 11 13 15 17 Piping Length (m) 19 21 23 25 220V Outlet Air (ºC) • 15.3 15.2 15.1 15.0 14.9 14.8 14.7 14.6 14.5 3 5 7 9 11 13 15 17 Piping Length (m) 60 19 21 23 25 17.1.2 Cooling Characteristic o Room temperature: o Operation condition: o Piping length: 27°C (DBT), 19°C (WBT) High fan speed 5.0m 220V Current (A) 17.00 16.00 15.00 14.00 13.00 12.00 11.00 30 35 40 45 Outdoor Temperature (ºC) 50 55 Gas Side Piping Pressure (MPa) 220V 0.550 0.520 0.490 0.460 0.430 0.400 30 35 40 45 Outdoor Temperature (ºC) 50 55 Capacity (kW) 220V 7.00 6.70 6.40 6.10 5.80 5.50 5.20 4.90 30 35 40 45 Outdoor Temperature (ºC) 50 55 220V 16.0 Outlet Air (ºC) • CS-C24KKS CU-C24KKS 15.5 15.0 14.5 14.0 13.5 13.0 30 35 40 45 Outdoor Temperature (ºC) 61 50 55 Piping Length Characteristic o Outdoor temperature: 35°C (DBT), 24°C (WBT) o Operation condition: High fan speed o Piping length: 5.0m 220V 12.20 Current (A) 12.00 11.80 11.60 11.40 11.20 11.00 3 5 7 9 11 13 15 17 Piping Length (m) 19 21 23 25 Gas Side Piping Pressure (MPa) 220V 0.430 0.420 0.410 0.400 0.390 0.380 0.370 0.360 3 5 7 9 11 13 15 17 19 21 23 25 Piping Length (m) Capacity (kW) 220V 6.60 6.50 6.40 6.30 6.20 6.10 6.00 5.90 5.80 3 5 7 9 11 13 15 17 Piping Length (m) 19 21 23 25 220V 14.5 Outlet Air (ºC) • 14.3 14.1 13.9 13.7 13.5 3 5 7 9 11 13 15 17 Piping Length (m) 62 19 21 23 25 18. Exploded View and Replacement Parts List 18.1 Indoor Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 63 REF. NO. PART NAME & DESCRIPTION QTY CS-C18KKS CS-C24KKS 1 CHASSY COMPLETE 1 CWD50C1654 ← 2 FAN MOTOR 1 L6CBYYYL0037 L6CBYYYL0039 3 CROSS FLOW FAN COMPLETE 1 CWH02C1077 ← 4 BEARING ASS’Y 1 CWH64K007 ← 5 SCREW - CROSS FLOW FAN 1 CWH551146 ← 6 ION GENERATOR 1 CWH94C0028 ← 7 EVAPORATOR 1 CWB30C3126 CWB30C3268 8 FLARE NUT (LIQUID) 1 CWT251026 ← REMARK O 9 FLARE NUT (GAS) 1 CWT251062 CWT251036 10 E-ION AIR PURIFYING SYSTEM 1 CWD93C1090 ← 11 HOLDER SENSOR 1 CWH32143 ← 12 BACK COVER CHASSIS 1 CWD933031 ← 13 CONTROL BOARD CASING 1 CWH102370 ← 14 TERMINAL BOARD COMPLETE 1 CWA28C2393 CWA28C2394 O 15 ELECTRONIC CONTROLLER - MAIN 1 CWA73C4492 CWA73C4493 O 16 ELECTRONIC CONTROLLER - POWER 1 CWA745303 CWA745620 O 17 ELECTRONIC CONTROLLER-HVU 1 CWA745348 ← O 18 ELECTRONIC CONTROLLER-INDICATOR 1 CWA745820 ← O 19 ELECTRONIC CONTROLLER-RECEIVER 1 CWA745288 ← O 20 COVER FOR RECEIVER(BOTTOM) 1 CWD933209 ← 21 COVER FOR RECEIVER(UPPER) 1 CWD933022 ← 22 INDICATOR HOLDER 1 CWD933021 ← 23 SENSOR COMPLETE 1 CWA50C2401 ← O 24 SENSOR COMPLETE(ECO) 1 CWA50C2709 ← O 1 CWA745791 ← O 1 CWA745790 ← O 1 CWA67C8484 ← 25 26 ELECTRONIC CONTROLLER (ECO SENSOR) ELECTRONIC CONTROLLER (COMPARATOR) 27 LEAD WIRE - PCB ECO 28 COVER FOR PCB ECO(BOTTOM) 1 CWD933193 ← 29 COVER FOR PCB ECO(UPPER) 1 CWD933192 ← 30 DISCHARGE GRILLE COMPLETE 1 CWE20C3007 ← 31 VERTICAL VANE 15 CWE241289 ← 32 CONNECTING BAR 1 CWE261156 ← 33 CONNECTING BAR 1 CWE261158 ← 34 CONNECTING BAR 1 CWE261157 ← 35 CONNECTING BAR 1 CWE261159 ← 36 CONNECTING BAR 1 CWE261160 ← 37 A.S.MOTOR,DC SINGLE 12V 300OHM 1 CWA981241 ← O 38 A.S MOTOR,DC SINGLE 12V300 OHM 1 CWA98K1014 ← O 39 HORIZONTAL VANE 1 CWE24C1295 ← 40 CAP - DRAIN TRAY 1 CWH521096 ← 41 CONTROL BOARD TOP COVER 1 CWH131350 ← 42 CONTROL BOARD FRONT COVER 1 CWH13C1183 ← 43 REMOTE CONTROL COMPLETE 1 CWA75C3560 ← O 44 FRONT GRILLE COMPLETE 1 CWE11C4737 ← O 45 INTAKE GRILLE COMPLETE 1 CWE22C1483 ← O 46 GRILLE DOOR 1 CWE14C1029 ← 47 E-ION FILTER 2 CWD00K1017 ← 48 SCREW - FRONT GRILLE 4 XTT4+16CFJ ← 49 CAP - FRONT GRILLE 3 CWH521194 ← 64 50 DRAIN HOSE 1 CWH851173 ← 51 BAG COMPLETE - INSTALLATION SCREW 1 CWH82C1705 ← 52 INSTALLATION PLATE 1 CWH361098 ← 53 FULCRUM 2 CWH621103 ← 54 OPERATING INSTRUCTION 1 CWF567115 ← 55 INSTALLATION INSTRUCTION 1 CWF614219 ← 56 INSTALLATION INSTRUCTION 1 CWF614220 ← 57 POWER SUPPLY CORD 1 CWA20C2836 ← (Note) • All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488). • “O” marked parts are recommended to be kept in stock. 65 18.2 Outdoor Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 66 REF. NO. QTY CU-C18KKS CU-C24KKS 1 CHASSY ASS’Y PART NAME & DESCRIPTION 1 CWD50K2115 CWD50K2100 2 SOUND PROOF MATERIAL 2 CWG302408 ← 3 FAN MOTOR BRACKET 1 CWD541065 ← 4 SCREW - FAN MOTOR BRACKET 2 CWH551217 ← 5 FAN MOTOR 1 CWA951401J CWA951399J 6 SCREW - FAN MOTOR MOUNT 3 CWH55252J ← 7 PROPELLER FAN ASS’Y 1 CWH03K1017 ← 8 NUT - PROPELLER FAN 1 CWH561038J ← REMARK O 9 COMPRESSOR 1 2KS252F5AA04 2J39S236A1A 10 PACKING 3 CWB81043 ← 11 ANTI - VIBRATION BUSHING 3 CWH50055 ← 12 NUT - COMPRESSOR MOUNT 3 CWH561049 ← 13 CONDENSER 1 CWB32C2966 CWB32C2684 14 CAPILLARY TUBE ASS’Y 1 CWB15K1252 CWB15K1282 15 STRAINER 1 CWB11025 ← 16 HOLDER COUPLING 1 CWH351036 ← 17 2-WAY VALVE (LIQUID) 1 CWB021175 ← O 18 3-WAY VALVE (GAS) 1 CWB011483 CWB011484 O 21 TERMINAL COVER 1 CWH171011 CWH171012 22 NUT - TERMINAL COVER 1 CWH7080300J ← 23 SOUND PROOF BOARD 1 CWH151056 ← 24 TERMINAL BOARD ASS’Y 1 CWA28K1064J ← 26 CAPACITOR - COM. 1 CWA312078 CWA312088 27 HOLDER CAPACITOR 1 CWH30060 CWH30071 28 CAPACITOR - F.M 1 DS441355NPQA ← 29 CABINET SIDE PLATE 1 CWE041082A ← 30 CABINET SIDE PLATE COMPLETE 1 CWE04C1127 ← 31 CABINET FRONT PLATE ASS’Y 1 CWE06K1045 ← 32 CABINET TOP PLATE 1 CWE03K1011A ← 33 CONTROL BOARD COVER COMP 1 CWH131168 ← 34 HANDLE 1 CWE161010 ← 35 CONTROL BOARD COVER(RIGHT-TOP) 1 CWH131169A ← 36 HANDLE 2 CWE16000E ← 37 THERMOSTAT 1 - CWA151061 44 WIRE NET 1 CWD041041A ← 45 OVERLOAD PROTECTOR WITH WIRE 1 CWA67C7546 - O O O (Note) • All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488). “O” marked parts are recommended to be kept in stock. Printed in Malaysia SSYW1006-00 67
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2010:07:05 14:43:04+08:00 Modify Date : 2010:07:07 07:51:38+08:00 Subject : Complete Service Manual Producer : Acrobat Distiller 7.0.5 (Windows) Creation Date : 2010:07:05 14:43:04+08:00 Mod Date : 2010:07:07 07:51:38+08:00 Author : Global CS Centre PHAAM Malaysia Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2010:07:07 07:51:38+08:00 Document ID : uuid:08b75f8c-ab49-4246-a3d5-e665bf289f0b Instance ID : uuid:e49b61ef-9d7f-4893-a102-fae3b2ea76eb Format : application/pdf Title : Panasonic Air Conditioner Creator : Global CS Centre PHAAM Malaysia Description : Complete Service Manual Page Count : 67EXIF Metadata provided by EXIF.tools