CMC 256plus Technical Data Sheet Brochure ENU
User Manual: CMC-256plus-Technical-Data-Sheet-Brochure-ENU
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
CMC 256plus CMC 256plus: 6 Phase Current + 4 Phase Voltage Test Set and Universal Calibrator The CMC 256plus is the first choice for applications requiring very high accuracy. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibration tool. Its high precision allows the calibration of a wide range of measuring devices, including: electricity meters of class 0.2S, measuring transducers, power quality measurement devices and phasor measurement units (PMU). Its unique accuracy and flexibility make the CMC 256plus ideal for protection and measurement equipment manufacturers for research and development, production and type testing. Operation: PC or CMControl Technical Data 1 Current generators Voltage generators Setting 6-phase AC (L-N) range 3-phase AC (L-N) 1 x 0 ... 75 A (Group A II B), 2 x 0 ... 37.5 A DC (3L-N) 1 x 0 ... ±35 A (Group A II B), 2 x 0 ... ±17.5 A 6-phase AC (L-N) Group A 1-phase and B in AC (L-L) series 10 Accuracy 2 Distortion (THD+N) 4 Ranges Resolution (for respective range) Max. compliance voltage (L-N)/(L-L) Connection 1 x 0 ... 600 V DC (L-N) 3-phase AC (L-N) Power 4 x 0 ... ±300 V 3 x 100 VA typ. at 100 ... 300 V 3 x 85 VA guar. at 85 ... 300 V 4 x 75 VA typ. at 100 ... 300 V 4 x 50 VA guar. at 85 ... 300 V 1 x 200 VA typ. at 100 ... 300 V 1 x 150 VA guar. at 75 ... 300 V 1 x 275 VA typ. at 200 ... 600 V 1 x 250 VA guar. at 200 ... 600 V 1 x 420 W typ. at ±300 V 1 x 360 W guar. at ±300 V 4-phase AC (L-N) 1-phase AC (L-N) 1-phase AC (L-L) DC (L-N) 300 250 200 150 100 50 0 0 1-phase AC (L-L) 1-phase AC (L-N) 3-phase AC (L-N) 4-phase AC (L-N) 100 Accuracy 5 25 50 Output current / A 75 error < 0.015 % rd.3 + 0.005 % rg.3 typ. at 0 ... 12.5 A error < 0.04 % rd. + 0.01 % rg. guar. at 0 ... 12.5 A < 0.025 % typ., < 0.07 % guar. 1.25 A / 12.5 A (Group A, B) or 2.5 A / 25 A (Group A II B) 50 µA / 100 µA / 500 µA / 1 mA 200 300 400 500 Output voltage / V 600 Distortion (THD+N) 4 Error < 0.015 % rd.3 + 0.005 % rg.3 typ. at 0 ... 300 V Error < 0.04 % rd. + 0.01 % rg. guar. at 0 ... 300 V 0.015 % typ., < 0.05 % guar. Ranges 150 V / 300 V Resolution Connection 5 mV / 10 mV in range 150 V / 300 V 4 mm (0.16 in) banana sockets / combination socket (1,2,3,N) Generators, general Frequency 15 Vpk / 60 Vpk 4 mm (0.16 in) banana sockets / combination socket (Group A only) All data specified are guaranteed, except where indicated otherwise. OMICRON guarantees the specified data for one year after factory calibration, within 23 °C ±5 °C (73 °F ±10 °F) in the frequency range from 10 to 100 Hz and after a warm-up phase > 25 minutes 2 Rload: 0 ... 0.5 Ω 3 rd. = reading, rg. = range 4 THD+N: Values at 50/60 Hz, > 1 A / 20 V with 20 kHz bandwidth 5 Rload: > 250 Ω 6 Amplitude derating at > 1000 Hz 7 Data are valid from 0.1 to 12.5 A (current amplifier A or B) and 50 to 300 V (voltage amplifier) at 50/60 Hz Permissible load for current outputs: Range 1.25 A: 0 to 1 Ω and 1 VA max., cos φ = 0.5 to 1 Range 12.5 A: 0 to 0.5 Ω and 6 VA max., cos φ = 0.5 to 1 Permissible load for voltage outputs: 10 VA max. at 50 to 300 V, cos φ = 0.5 to 1 1 1-phase AC (L-L) 1-phase AC (L-N) 3-phase AC (L-N) 0 3-phase AC (L-N) 4 x 0 ... 300 V (VL4(t) automatically calculated: VL4 = (VL1+VL2+VL3)*c or freely programmable) 3 x 0 ... 300 V Output power (typ.) / VA 6 x 80 VA typ. at 8.5 A, 6 x 70 VA guar. at 7.5 A 3-phase AC (L-N) 3 x 160 VA typ. at 17 A (Group A II B) 3 x 140 VA guar. at 15 A (Group A II B) 1-phase AC (3L-N) 1 x 480 VA typ. at 51 A (Group A II B), 2 x 240 VA at 25.5 A 1 x 420 VA guar. at 45 A (Group A II B), 2 x 210 VA at 22.5 A 1-phase AC (L-L) 1 x 320 VA typ. at 8.5 A (Group A II B), 2 x 160 VA at 8.5 A 1 x 280 VA guar. at 15 A (Group A II B), 2 x 140 VA at 7.5 A 1-phase AC (L-L-L-L) 1 x 320 VA typ. at 8.5 A (40 VRMS, Group A and B in series) 1 x 280 VA guar. at 7.5 A (40 VRMS, Group A and B in series) 1 x 480 W typ. at ±35 A (Group A II B), DC (3L-N) 2 x 240 W at ±17.5 A 1 x 470 W guar. at ±35 A (Group A II B), 2 x 235 W at ±17.5 A 500 400 300 200 100 0 4-phase AC (L-N) 3 x 0 ... 25 A (Group A II B) 1-phase AC (3L-N) Output power (typ.) / VA Power Setting range 6 x 0 ... 12.5 A Phase Range sine signals 10 ... 1000 Hz Range harmonics / interharmonics 6 Range transient signals 6 Accuracy / drift 10 ... 3000 Hz ±0.5 ppm / ±1 ppm Resolution < 5 µHz Angle range -360° ... +360° Resolution 0.001° Error at 50 / 60 Hz < 0.005° typ., < 0.02° guar. Bandwidth (-3 dB) Simulated power S, P (calibration of energy meters) DC ... 3.1 kHz 3.1 kHz Accuracy 7 Error < 0.05 % rd. typ., < 0.1 % rd. guar. Temperature drift < 0.001 % / °C typ., < 0.005 % / °C guar. Technical Data CMC 256plus (continued) Low level outputs 1 Binary outputs, transistor Number of outputs 6 (12 with Option LLO-2) Type Open collector transistor outputs Setting range Max. output current 0 ... ±10 Vpk 1 mA Number 4 Update rate 10 kHz Accuracy Imax 5 mA Resolution Error < 0.025 % typ., < 0.07 % guar. at 1 ... 10 Vpk 250 µV Connection 16 pin combination socket (rear side) Distortion (THD+N) 2 < 0.015 % typ., < 0.05 % guar. Unconventional CT/VT simulation linear, Rogowski (transient and sinewave) Measuring range 0 ... ±10 V Overload indication Yes Accuracy Isolation SELV Input impedance Error < 0.003 % rg. 3 typ., < 0.02 % rg. guar. 1 MΩ Usability Completely independent from internal amplifier outputs 16 pin combination socket (rear side) DC current measuring input Connection Auxiliary DC supply Voltage ranges Power 0 ... 264 VDC, 0.2 A / 0 ... 132 VDC, 0.4 A / 0 ... 66 VDC, 0.8 A Max. 50 W Accuracy Error < 2 % typ., < 5 % guar. DC voltage measuring input Measuring range 0 ... ±1 mA, 0 ... ±20 mA Accuracy Error < 0.003 % rg. 3 typ., < 0.02 % rg. guar. Input impedance 15 Ω Analog AC+DC measuring inputs 4 Number AC + DC analog voltage inputs (current measurement with external current clamps or shunt resistors) 10 Number 10 Nominal input ranges (RMS values) 100 mV, 1 V, 10 V, 100 V, 600 V Trigger criteria Amplitude accuracy Error < 0.06 % typ., < 0.15 % guar. Input characteristics Toggling of potential-free contacts or DC voltage compared to threshold voltage 0 ... ±600 VDC threshold or potential-free Bandwidth DC ... 10 kHz Ranges 100 mV / 1 V / 10 V / 100 V / 600 V Sampling frequency 28.44 kHz, 9.48 kHz, 3.16 kHz Resolution of threshold 500 kΩ // 50 pF Transient input buffer at 28 kHz Sample rate ±2 mV, ±20 mV, ±200 mV, ±2 V, ±20 V in ranges 10 kHz (resolution 100 µs) Input impedance Time stamping accuracy ±0.00015 % of rd.3 ±70 µs Max. measuring time Infinite Debounce / Deglitch time 0 ... 25 ms / 0 ... 25 ms Counting function < 3 kHz at pulse width > 150 µs Galvanic isolation 5 galvanically isolated groups (2+2+2+2+2) Max. input voltage CAT IV / 150 V, CAT III / 300 V, CAT II / 600 V (850 Vpk) Input overload indication 3.5 s for 10 input channels / 35 s for 1 input channel 31 s for 10 input channels / 5 min. for 1 input channel Threshold voltage, power quality trigger: sag, swell, harmonic, frequency, frequency change, notch I (AC + DC), V (AC + DC), phase, frequency, power, harmonics, transient recording, event recording, trend recording Yes Input protection Yes Max. input voltage CAT IV / 150 V, CAT III / 300 V, CAT II / 600 V (850 Vpk) 5 groups (2+2+2+2+2) Binary inputs Counter inputs 100 kHz Number 2 Max. counting frequency 100 kHz Pulse width > 3 µs Threshold voltage 6V Voltage hysteresis 2V Max. input voltage ±30 V Isolation SELV Connection 16 pin combination socket (rear side) Trigger on overload Supported generators Current generators Timer accuracy Error < 1 ms Binary outputs, relays Type Number Potential-free relay contacts, software controlled 4 Break capacity AC Vmax: 300 VAC / Imax: 8 A / Pmax: 2000 VA Break capacity DC Vmax: 300 VDC / Imax: 8 A / Pmax: 50 W 1 2 3 4 For directly testing relays with low level inputs by simulating signals from non conventional CTs and VTs with low level interfaces and for controlling external amplifier units THD+N: Values at 50/60 Hz, 20 kHz measurement bandwidth, nominal value, and nominal load rd. = reading, rg. = range Up to three inputs can be used for measuring RMS values, frequency, and phase angle without the EnerLyzer software license. Full functionality requires EnerLyzer software license Type Transient input buffer at 3 kHz Transient trigger Measurement functions Galvanic isolation Time synchronization Timing accuracy IRIG-B synchronization with CMIRIG-B GPS synchronization with CMGPS 588 To external voltage Error < 1 µs typ., < 5 µs guar. Error < 1 µs typ., < 5 µs guar. Reference signal on binary input 10: 10 ... 300 V / 15 ... 70 Hz Precision Time Protocol (PTP) IEEE 1588-2008 IEEE C37.238-2011 (Power Profile) With the unique PermaSync functionality, analog and Sampled Values outputs stay permanently in sync with the internal CMC time reference. When a CMC is time-synchronized (IRIG-B, GPS, or PTP), the output quantities are continuously synchronized to the external time source. With CMIRIG-B it is also possible to transmit the internal PPS signal of the CMC to the device under test (e.g. PMUs or IEDs stimulated with a synchronized Sampled Values data stream). Miscellaneous IEC 61850 GOOSE 1 Simulation Mapping of binary outputs to data attributes in published GOOSE messages. Number of virtual binary outputs: 360 Number of GOOSEs to be published: 128 Mapping of data attributes from subscribed GOOSE messages to binary inputs. Number of virtual binary inputs: 360 Number of GOOSEs to be subscribed: 128 Type 1A; Class P2/3 (IEC 61850-5). Processing time (application to network or vice versa): < 1 ms Selectable priority and VLAN-ID Weight 16.0 kg (35.3 lbs) Dimensions (W x H x D, without handle) PC connection 450 x 145 x 390 mm (17.7 x 5.7 x 15.4 in) Signal indication (LED) Two PoE 4 Ethernet ports: • 10/100/1000 Base-TX • IEEE 802.3af compliant • Port capability limited to one Class 1 (3.84 W) and one Class 2 (6.49 W) powered device USB port: • USB 2.0 High Speed up to 480 Mbit/s USB 1.1-compatible > 42 V for voltage outputs and AUX DC IEC 61850 Sampled Values (Publishing) 1 Connection to ground (earth) 4 mm (0.16 in) banana socket (rear side) Specification Hardware diagnostics Self diagnostics upon each start-up Galvanically separated groups The following groups are galvanically separated from each other: mains, voltage amplifier output, current amplifier group A/B, auxiliary DC supply, binary/ analog input All current and voltage outputs are fully overload and short circuit proof and protected against external high-voltage transient signals and over temperature Subscription Performance VLAN support VLAN support According to the “Implementation Guideline for Digital Interface to Instrument Transformers Using IEC 61850-9-2“ of the UCA International Users Group 80 samples per cycle for nominal frequencies of 50 Hz and 60 Hz. Synchronization attribute (smpSynch) is set when the CMC is in synchronized operation mode. Sample count (smpCnt) zero is aligned with top of the second. Accuracy data see above Selectable priority and VLAN-ID Max. number of SV streams 2 (with option LLO-2: 3 SV streams) Sampling Rate Synchronization Protection Certifications Power supply Nominal input voltage 2 100 – 240 VAC, 1-phase Permissible input voltage 85 ... 264 VAC Nominal frequency 50/60 Hz Permissible frequency range 45 ... 65 Hz Rated current 12 A at 115 V / 10 A at 230 V Connection Standard AC socket (IEC 60320) Developed and manufactured under an ISO 9001 registered system Environmental conditions Operation temperature 3 0 ... +50 °C (+32 ... +122 °F) Storage temperature -25 ... +70 °C (-13 ... +158 °F) Humidity range Relative humidity 5 ... 95 %, non-condensing Vibration IEC 60068-2-6 (20 m/s at 10 ... 150 Hz) Shock IEC 60068-2-27 (15 g/11 ms half-sine) 2 Safety standards, electromagnetic compatibility EMC International USA Safety The product adheres to the electromagnetic compa tibility (EMC) Directive 2004/108/EC (CE conform). IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3 FCC Subpart B of Part 15 Class A The product adheres to the low voltage Directive 2006/95/EC (CE conform). International / USA IEC 61010-1 / UL 61010-1 Canada CAN/CSA-C22.2 No 61010-1-04 Ordering Information CMC 256plus with Test Universe software VE002701 CMC 256plus Basic VE002702 CMC 256plus Protection VE002703 CMC 256plus Advanced Protection VE002704 CMC 256plus Universal VE002705 CMC 256plus Meter VE002706 CMC 256plus Measurement VE002720 CMC 256plus Recloser CMC 256plus with CMControl (without Test Universe software) VE002715 CMC 256plus with CMControl P VE002719 CMC 256plus with CMControl R VE002721 CMC 256plus with CMControl P App activation key VE002723 CMC 256plus with CMControl R App activation key The CMControl can also be ordered as add-on together with a CMC 256plus with Test Universe software or as a later upgrade. CMC 256plus hardware options VEHO2703 Option LLO-2 if ordered with a new unit VEHO2704 Option LLO-2 if ordered as an upgrade 1 2 3 4 Testing with GOOSE and Sampled Values functionality requires software licences for the corresponding configuration modules For line inputs below 115 VAC, it is not possible to drive all outputs (voltage output, current output, Aux DC) simultaneously at full load. All other technical specifications (e.g. the maximum output power of a single amplifier) are not affected For an operational temperature above +30 °C (+86 °F) a duty cycle of down to 50 % may apply PoE = Power over Ethernet
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : OMICRON electronics GmbH Create Date : 2015:09:15 08:01:17+02:00 Modify Date : 2015:09:16 14:54:48+02:00 Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2015:09:16 14:54:48+02:00 Format : application/pdf Title : CMC 256plus Technical Data Creator : OMICRON electronics GmbH Document ID : uuid:dcad1069-8482-48f7-a8ca-cf9824edc42d Instance ID : uuid:f2c08cfd-7db9-49d1-a3c7-343a26f3b2dc Page Layout : TwoPageRight Page Count : 3EXIF Metadata provided by EXIF.tools