Test Report issued under the responsibility of:

TEST REPORT
IEC 60335-2-40

Safety of household and similar electrical appliances
Part 2-40: Particular requirements for electrical heat pumps, air
conditioners and dehumidifiers
Report Reference No. ...................... :

GZES120900879606

Date of issue....................................... :

2013-06-26

Total number of pages ........................

41

CB Testing Laboratory .................... :

SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab
Guangzhou

Address............................................... :

198 Kezhu Road, Scientech Park, Guangzhou Economic &
Technology Development District, Guangzhou, Guangdong, China
510663

Applicant's name.............................. :

Gree Electric Appliances, Inc. of Zhuhai

Address............................................... :

Jinji West Road, Qianshan, Zhuhai, Guangdong, China

Test specification:
Standard ............................................. :

IEC 60335-2-40:2002 (4. Edition) + A1:2005 (incl. Corr.1:2006) +
A2:2005 with
IEC 60335-1:2001 (4. Edition) (incl. Corr.1:2002) + A1:2004 (incl.
Corr.1:2005) + A2:2006 (incl. Corr.1:2006)
IEC 62233:2005 (1. Edition)

Test procedure ................................... :

SGS-CSTC

Non-standard test method…………..:

N/A

Test Report Form No. ...................... :

IEC60335_2_40F

Test Report Form(s) Originator.......... :

VDE Testing and Certification Institute

Master TRF......................................... :

Dated 2009-11

Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright
owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's
interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Page 2 of 41
Test item description……………….:

Report No. GZES120900879606

Split-Type Air-Conditioner

Trade Mark……………………………:
Manufacturer/Address………………:

Same as applicant

Factory/Address……………………...:

Same as applicant

Model/Type reference ........................ :

GWH09MB-K3DNA3K (Indoor unit: GWH09MB-K3DNA3K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DND3K (Indoor unit: GWH09MB-K3DND3K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNA2K (Indoor unit: GWH09MB-K3DNA2K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNA5K (Indoor unit: GWH09MB-K3DNA5K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DND8D (Indoor unit: GWH09MB-K3DND8D/I,
Outdoor unit: GWH09MB-K3DND8D/O);
GWH09MB-K3DNB3K(Indoor unit: GWH09MB-K3DNB3K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNE1K(Indoor unit: GWH09MB-K3DNE1K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNC9K(Indoor unit: GWH09MB-K3DNC9K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNA4K(Indoor unit: GWH09MB-K3DNA4K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNE2K (Indoor unit: GWH09MB-K3DNE2K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNE3K (Indoor unit: GWH09MB-K3DNE3K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNB7K (Indoor unit: GWH09MB-K3DNB7K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNC5K (Indoor unit: GWH09MB-K3DNC5K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNC1K (Indoor unit: GWH09MB-K3DNC1K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH09MB-K3DNC8K (Indoor unit: GWH09MB-K3DNC8K/I, Outdoor
unit: GWH09MB-K3DNA3K/O);
GWH12MB-K3DNA3K (Indoor unit: GWH12MB-K3DNA3K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DND3K (Indoor unit: GWH12MB-K3DND3K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNA2K (Indoor unit: GWH12MB-K3DNA2K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNA5K (Indoor unit: GWH12MB-K3DNA5K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DND8D (Indoor unit: GWH12MB-K3DND8D/I,
Outdoor unit: GWH12MB-K3DND8D/O)
GWH12MB-K3DNB3K(Indoor unit: GWH12MB-K3DNB3K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNE1K(Indoor unit: GWH12MB-K3DNE1K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNC9K(Indoor unit: GWH12MB-K3DNC9K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNA4K(Indoor unit: GWH12MB-K3DNA4K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNE2K (Indoor unit: GWH12MB-K3DNE2K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNE3K (Indoor unit: GWH12MB-K3DNE3K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNB7K (Indoor unit: GWH12MB-K3DNB7K/I, Outdoor
unit: GWH12MB-K3DNA3K/O);
GWH12MB-K3DNC5K (Indoor unit: GWH12MB-K3DNC5K/I, Outdoor

TRF No. IEC60335_2_40F

Page 3 of 41

Report No. GZES120900879606

unit: GWH12MB-K3DNA3K/O)
GWH12MB-K3DNC1K (Indoor unit: GWH12MB-K3DNC1K/I, Outdoor
unit: GWH12MB-K3DNA3K/O)
GWH12MB-K3DNC8K (Indoor unit: GWH12MB-K3DNC8K/I, Outdoor
unit: GWH12MB-K3DNA3K/O)
Ratings................................................ :

TRF No. IEC60335_2_40F

220-240 V~; 50 Hz;
1, GWH09MB-K3DNA3K, GWH09MB-K3DND3K, GWH09MBK3DNA2K, GWH09MB-K3DNA5K, GWH09MB-K3DNB3K,
GWH09MB-K3DNE1K, GWH09MB-K3DNC9K, GWH09MBK3DNA4K, GWH09MB-K3DNE2K, GWH09MB-K3DNE3K,
GWH09MB-K3DNB7K, GWH09MB-K3DNC5K, GWH09MBK3DNC1K, GWH09MB-K3DNC8K:
Cooling: 1300 W; Heating: 1400 W;
2, GWH09MB-K3DND8D: Cooling: 1550 W, Heating: 1400 W;
3, GWH12MB-K3DNA3K, GWH12MB-K3DND3K, GWH12MBK3DNA2K, GWH12MB-K3DNA5K, GWH12MB-K3DNB3K,
GWH12MB-K3DNE1K, GWH12MB-K3DNC9K, GWH12MBK3DNA4K, GWH12MB-K3DNE2K, GWH12MB-K3DNE3K,
GWH12MB-K3DNB7K, GWH12MB-K3DNC5K, GWH12MBK3DNC1K, GWH12MB-K3DNC8K:
Cooling: 1400 W; Heating: 1550 W;
4, GWH12MB-K3DND8D: Cooling: 1600 W; Heating: 1550 W

Page 4 of 41

Report No. GZES120900879606

IEC 60335-2-40

Testing procedure and testing location:
CB Testing Laboratory:
Testing location/ address .........................:

Associated CB Laboratory:

SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab
Guangzhou
198 Kezhu Road, Scientech Park, Guangzhou Economic &
Technology Development District, Guangzhou, Guangdong,
China 510663
N/A

Testing location/ address .........................:
Tested by (name + signature) .......:
Approved by (+ signature) .............:
Testing procedure: TMP
Tested by (name + signature) .......:

George Gu

Approved by (+ signature) ..............:

Gaven Deng

Testing location/ address .........................:
Testing procedure: WMT

Gree Electric Appliances, Inc. of Zhuhai
Jinji West Road, Qianshan, Zhuhai, Guangdong, China
N/A

Tested by (name + signature) .......:
Witnessed by (+ signature) ............:
Approved by (+ signature) .............:
Testing location/ address .........................:
Testing procedure: SMT

N/A

Tested by (name + signature) .......:
Approved by (+ signature) ..............:
Supervised by (+ signature) ..........:
Testing location/ address .................. :
Testing procedure: RMT
Tested by (name + signature) .......:
Approved by (+ signature) ..............:
Supervised by (+ signature) ..........:
Testing location/ address .........................:

TRF No. IEC60335_2_40F

N/A

Page 5 of 41

Report No. GZES120900879606

IEC 60335-2-40

Summary of testing:
Tests performed (name of test and test clause):

Testing location:

Tests according to the following standards were
carried out:

Tests of clause 10, 11, 13, 19.2, 29 and were carried
out at:

EN 60335-2-40: 2003 + A11: 2004 + A12: 2005 +
A1: 2006 + A2: 2009 + A13: 2012;
EN 60335-1: 2002 + A11: 2004 + A1: 2004 + A12:
2006 + A2: 2006 + A13: 2008 + A14: 2010 + A15:
2011;
EN 62233: 2008

Gree Electric Appliances, Inc. of Zhuhai
Jinji West Road, Qianshan, Zhuhai, Guangdong,
China
Other clauses were carried out at CBTL.

Tests of clause 10, 11, 13, 19.2, 24, 29 and 30 were
conducted on model GWH09MB-K3DNC1K,
GWH12MB-K3DNC1K.
The submitted samples complied with above
standards.

Summary of compliance with National Differences:
European group differences had been taken into account.
Copy of marking plate:
Labels for model GWH09MB-K3DNC1K:



TRF No. IEC60335_2_40F

Page 6 of 41
IEC 60335-2-40

Labels for model GWH09MB-K3DNC8K:

Labels for model GWH12MB-K3DNC1K:

TRF No. IEC60335_2_40F

Report No. GZES120900879606

Page 7 of 41
IEC 60335-2-40

Labels for model GWH12MB-K3DNC8K:

TRF No. IEC60335_2_40F

Report No. GZES120900879606

Page 8 of 41

Report No. GZES120900879606

IEC 60335-2-40

Test item particulars .................................................. :
Classification of installation and use ............................ : Fixed appliance
Supply Connection ....................................................... : Non-detachable flexible cord fitted with a plug
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A
- test object does meet the requirement ....................... : P (Pass)
- test object does not meet the requirement ................. : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ............................................ : 2013-04-20
Date (s) of performance of tests ................................... : From 2013-04-20 to 2013-06-20
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.
This document is issued by the company under its General Conditions of Service accessible at
http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification
and jurisdiction issues defined therein.
Any holder of this document is advised that information contained hereon reflects the Company’s findings at
the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole
responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the
fullest extent of the law.
Unless otherwise stated: (a) the results shown in this document refer only to the sample(s) tested and (b) such
sample(s) are retained for 3 months. This document cannot be reproduced except in full, without prior
approval of the company.
The test report includes the following additional documents to the original TRF:
Attachment I: 2 pages of photo documentation;
Attachment II: 1 page of equipment list for TMP
General product information:
Split-type air-conditioner for household used only, the refrigerant is R410A.
The appliances have cooling and heating functions.
Model GWH09MB-K3DNA3K is all the same as model GWH12MB-K3DNA3K except for mass of refrigerant,
rating labels and programme of outdoor unit main board.
Model GWH09MB-K3DND3K is all the same as model GWH09MB-K3DNA3K except for display panel of
indoor unit.
Model GWH12MB-K3DND3K is all the same as model GWH12MB-K3DNA3K except for display panel of
indoor unit.
Amendment-1:
The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Dec. 12, 2012 to
include the following additions, which were considered technical modifications:
1, Added six models: GWH09MB-K3DNA2K, GWH09MB-K3DNA5K, GWH09MB-K3DND8D, GWH12MBK3DNA2K, GWH12MB-K3DNA5K, GWH12MB-K3DND8D.
TRF No. IEC60335_2_40F

Page 9 of 41

Report No. GZES120900879606

IEC 60335-2-40
The differences between new models and original models were listed as below:
1)
Models GWH09MB-K3DNA2K and GWH09MB-K3DNA5K were all same as original model
GWH09MB-K3DNA3K except for the appearance of indoor unit display panel.
2)

Model GWH09MB-K3DND8D was all the same as original model GWH09MB-K3DNA3K except for the
appearance of indoor unit display panel, indoor unit main board and rated power input of cooling mode.
(The indoor unit main board of model GWH09MB-K3DND8D was all the same as model GWH09MBK3DNA3K except for the indoor fan motor running capacitor on main board.)

3)

Models GWH12MB-K3DNA2K and GWH12MB-K3DNA5K were all same as original model
GWH12MB-K3DNA3K except for the appearance of indoor unit display panel.

4)

Model GWH12MB-K3DND8D was all the same as original model GWH12MB-K3DNA3K except for the
appearance of indoor unit display panel, indoor unit main board and rated power input of cooling mode.
(The indoor unit main board of model GWH12MB-K3DND8D was all the same as model GWH12MBK3DNA3K except for the indoor fan motor running capacitor on main board.)

2, Alternative power cord and interconnection cord for models GWH09MB-K3DNA2K, GWH09MB-K3DNA5K,
GWH12MB-K3DNA2K, GWH12MB-K3DNA5K. Details see the table 24.1.
After reviewing, test of clause 30 was considered to carry out on the alternative fan motor running capacitors.
Amendment-2:
The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Dec. 28, 2012 to
include the following additions, which were considered technical modifications:
1, Added eight models: GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K, GWH09MBK3DNA4K, GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MB-K3DNC9K, GWH12MB-K3DNA4K.
The differences between new models and original models were listed as below:
1)
Models GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K and GWH09MBK3DNA4K were all same as original model GWH09MB-K3DNA3K except for the appearance of indoor
unit display panel.
2)

Models GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MB-K3DNC9K and GWH12MBK3DNA4K were all same as original model GWH12MB-K3DNA3K except for the appearance of indoor
unit display panel.

2, Alternative power cord and interconnection cord for models GWH09MB-K3DNB3K, GWH09MB-K3DNE1K,
GWH09MB-K3DNC9K, GWH09MB-K3DNA4K, GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MBK3DNC9K and GWH12MB-K3DNA4K. Details see the table 24.1.
3, Alternative a panel for model GWH09MB-K3DNA2K and GWH12MB-K3DNA2K.
After reviewing, no test was considered to carry out.
Amendment-3:
The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Jan. 21, 2013 to
include the following additions, which were considered technical modifications:
1, Added four new models: GWH09MB-K3DNE2K, GWH09MB-K3DNE3K, GWH12MB-K3DNE2K,
GWH12MB-K3DNE3K.
The differences between new models and original models were listed as below:
1) Model GWH09MB-K3DNE2K was all the same as original model GWH09MB-K3DNA3K except for the
appearance of indoor unit display panel and the shape of display board.
2) Model GWH09MB-K3DNE3K was all the same as original model GWH09MB-K3DNA3K except for the
appearance of indoor unit display panel.
3) Model GWH12MB-K3DNE2K was all the same as original model GWH12MB-K3DNA3K except for the
appearance of indoor unit display panel and the shape of display board.
4) Model GWH12MB-K3DNE3K was all the same as original model GWH12MB-K3DNA3K except for the
appearance of indoor unit display panel.
2, Alternative one panel for models GWH09MB-K3DND8D and GWH12MB-K3DND8D.
3, Alternative power cord and interconnection cord for the four new models. Details see the components in
bold in table 24.1.
After reviewing, no test was considered to be carried out.

TRF No. IEC60335_2_40F

Page 10 of 41

Report No. GZES120900879606

IEC 60335-2-40

Amendment-4:
The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on April 09, 2013 to
include the following additions and changes, which were considered technical modifications:
1, Added four new models: GWH09MB-K3DNB7K, GWH09MB-K3DNC5K, GWH12MB-K3DNB7K,
GWH12MB-K3DNC5K.
Models GWH09MB-K3DNB7K and GWH09MB-K3DNC5K were all the same as original model GWH09MBK3DNA3K except for the appearance of indoor unit display panel and the shape of display board. Details see
attachment I.
Models GWH12MB-K3DNB7K and GWH12MB-K3DNC5K were all the same as original model GWH12MBK3DNA3K except for the appearance of indoor unit display panel and the shape of display board. Details see
attachment I.
2, Added reactor, interconnection cord, power cord as alternative ones, details see the components in bold in
table 24.1.
3, Added chassis electrical heater for models GWH09MB-K3DNA4K, GWH09MB-K3DNA5K, GWH12MBK3DNA4K, GWH12MB-K3DNA5K, details see attachment I and table 24.1. The electrical heater would not
work during the appliance normal operation.
4, Updated the label of indoor fan motor. (the current mark on label was corrected from 0,215 A to 0,180 A,
detail see attachment I)
After reviewing, tests of clause 8, 16.3, 19.10, 22, 24, 25, 29 and 30 were considered to be necessary.
Amendment-5:
The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Jun 26, 2013 to
include the following additions and changes, which were considered technical modifications:
1, Added four new models: GWH09MB-K3DNC1K, GWH09MB-K3DNC8K, GWH12MB-K3DNC1K,
GWH12MB-K3DNC8K.
Models GWH09MB-K3DNC1K and GWH09MB-K3DNC8K are all the same as original model GWH09MBK3DNA3K except for the appearance of indoor unit display panel. Details see attachment I.
Models GWH12MB-K3DNC1K and GWH12MB-K3DNC8K are all the same as original model GWH12MBK3DNA3K except for the appearance of indoor unit display panel. Details see attachment I.
There are two colours for indoor unit display panels of models GWH09MB-K3DNC8K and GWH12MBK3DNC8K, Details see attachment I.
2, Added outdoor fan motor, Y1 capacitor as alternative ones, details see the components in bold in table
24.1.
After reviewing, tests of clause 10, 11, 13, 19.2, 24, 29 and 30 were considered to be necessary.

TRF No. IEC60335_2_40F

Page 11 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

Requirement + Test

10

POWER INPUT AND CURRENT

10.1

Power input at normal operating temperature, rated
voltage and normal operation not deviating from rated
power input by more than shown in table 1

10.2

Result

Verdict
—

(See appended table)

P

Deviation of appliance with one or more rated voltage
ranges (IEC 60335-1/A2)

N/A

Current at normal operating temperature, rated voltage
and normal operation not deviating from rated current
by more than shown in table 2

N/A

Deviation of appliance with one or more rated voltage
ranges (IEC 60335-1/A2)

N/A

11

HEATING

—

11.1

No excessive temperatures in normal use
(IEC 60335-2-40)

P

Compliance is checked by the tests of annex C, if (IEC 60335-2-40):

—

11.2

- temperature of motor winding exceeds values shown
in table 3 (IEC 60335-2-40)

N/A

- there is doubt about classification of insulation system
of the motor (IEC 60335-2-40)

N/A

Placing and mounting of appliance (IEC 60335-2-40):

—

- clearances to adjacent surfaces (IEC 60335-2-40);

P

- flow rates for liquid source or sink equipment be
minimum, except for fan coils where flow rates and
liquid temperatures be maximum
(IEC 60335-2-40/A2);

N/A

- static pressures (IEC 60335-2-40);

N/A

- means of adjusting the flow, flow for tests be
minimum obtainable (IEC 60335-2-40);

N/A

- adjustable limit controls set at maximum cut-out
setting and minimum differential (IEC 60335-2-40).

P

Appliances with supplementary heaters, use test
casing of clause 11.9 (IEC 60335-2-40)

N/A

11.2.1

Appliances with supplementary heaters, inlet duct
connected to inlet air opening (IEC 60335-2-40)

N/A

11.2.2

Appliance without supplementary heaters, air outlet
used (IEC 60335-2-40)

N/A

11.3

Temperature rise determine by thermocouples or
resistance method (IEC 60335-2-40)

11.4

Test performed at supply voltage between 0,94 and
1,06 times the rated voltage (IEC 60335-2-40)
Heating elements energized at voltage which gives an
electrical input of 1,15 times maximum rated power
input (IEC 60335-2-40)

TRF No. IEC60335_2_40F

P
240 V x 1,06 = 254,4 V

P
N/A

Page 12 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause
11.5

Requirement + Test

Result

Test conducted in heating mode and cooling mode, if
both exist (IEC 60335-2-40)

Verdict
P

All supplementary heating elements operative
simultaneously (IEC 60335-2-40)

N/A

11.6

Defrost test in most unfavourable conditions, if needed
(IEC 60335-2-40)

N/A

11.7

Appliances operated continuously until steady
conditions except for defrost tests (IEC 60335-2-40)

11.8

Temperatures not exceeding values of table 3
(IEC 60335-2-40/A2)

11.9

P
(See appended tables)

P

Protective devices do not operate (IEC 60335-2-40)

P

Sealing compound not flowing out (IEC 60335-2-40)

P

Temperature of air in outlet duct not exceed 90 °C
(IEC 60335-2-40)

N/A

Test casing and installation of appliances in
accordance with manufacturer’s instructions
(IEC 60335-2-40)

N/A

Glass fibre insulation for appliances without indication
of minimum clearances according to manufacturer;
thermocouple in contact with enclosure
(IEC 60335-2-40)

N/A

13

LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
TEMPERATURE

—

13.1

Leakage current not excessive and electric strength
adequate

P

Heating appliances operated at 1,15 times rated power
input .......................................................................... :
Motor-operated appliances and combined appliances
supplied at 1,06 times rated voltage........................ :

13.2

240 V x 1,06 = 254,4 V

P

Protective impedance and radio interference filters
disconnected before carrying out the tests

N/A

Leakage current measured by means of the circuit
described in figure 4 of IEC 60990

P

Leakage current measurements (IEC 60335-2-40)
13.3

N/A

(See appended table)

P

Appliance disconnected from supply and insulation is
immediately subjected to voltage having frequency of
50 Hz or 60 Hz for 1 min, in accordance with
IEC 61180-1 (IEC 60335-1/A1)

P

High-voltage source used for test is to be capable of
supplying short circuit current Is between the output
terminals after output voltage adjusted to appropriate
test voltage (IEC 60335-1/A1)

P

TRF No. IEC60335_2_40F

Page 13 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

Requirement + Test

Result

P

Overload release of circuit is not to be operated by any
current below tripping current Ir. Values of Is and Ir
given in table 5 for various high-voltage sources
(IEC 60335-1/A1)
No breakdown during the tests

Verdict

(See appended table)

P

19

ABNORMAL OPERATION

—

19.1

The risk of fire or mechanical damage under abnormal
or careless operation obviated (tests 19.2-19.14)
(IEC 60335-2-40)

P

Failure of transfer medium flow or of any control device
not result in a hazard (IEC 60335-2-40)

P

Electronic circuits so designed and applied that a fault
will not render the appliance unsafe (electric shock, fire
or mechanical hazard, dangerous malfunction) (test
19.11 and 19.12) (IEC 60335-2-40)

P

Test of appliance with motor rotors, other than
motor-compressors, operated for 15 days (360 h) or
until protection device opens circuit (IEC 60335-2-40)

P

19.2

Insulation of motor windings (IEC 60335-2-40) .......:

(See appended table)

P

Temperature of enclosure does not exceed (C)
(IEC 60335-2-40)......................................................:

(See appended table)

P

Temperature of the windings does not exceed the
values shown in the table ; temperature (C)
(IEC 60335-2-40)......................................................:

(See appended table)

P

Electric strength test as specified in 16.3, 72 h after the
beginning of the test (IEC 60335-2-40)

P

30 mA residual current device does not open
(IEC 60335-2-40)

P

At the end, leakage current between windings and
enclosure does not exceed 2 mA (IEC 60335-2-40)

P

24

COMPONENTS

—

24.1

Components comply with safety requirements in
relevant IEC standards

P

List of components

(See appended table)

P

Components not tested and found to comply with
relevant IEC standard for number of cycles specified,
tested in accordance with clause 24.1.1 to 24.1.9
(IEC 60335-1/A2)

N/A

Components not tested and found to comply with
relevant IEC standard, components not marked or not
used in accordance with its marking, tested under the
conditions occurring in the appliance

P

TRF No. IEC60335_2_40F

Page 14 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

24.1.1

24.1.2

24.1.3

24.1.4

Requirement + Test

Result

Verdict

Lampholders and starterholders not being tested and
found to comply with relevant IEC standard, tested as a
part of appliance and additionally according to gauging
and interchangeability requirements of relevant IEC
standard (IEC 60335-1/A2)

N/A

Motor-compressors not tested according to
IEC 60335-2-34 (not necessary to meet all
requirements of IEC 60335-2-34) (IEC 60335-2-40)

N/A

Capacitors likely to be permanently subjected to the
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or

P

tested according to annex F

N/A

Safety isolating transformers complying with
IEC 61558-2-6, or

N/A

tested according to annex G

N/A

Switches complying with IEC 61058-1, the number of
cycles of operation being at least
10 000, or

N/A

tested according to annex H

N/A

If the switch operates a relay or contactor, the complete
switching system is subjected to the test

N/A

Automatic controls complying with IEC 60730-1 with relevant part 2. The number of
cycles of operation being:

—

- thermostats: ................................................. 10 000

N/A

- temperature limiters: ...................................... 1000

N/A

- self-resetting thermal cut-outs (IEC 60335-2-40):3000

N/A

- voltage maintained non-self-resetting thermal
cut-outs: .......................................................... 1000

N/A

- other non-self-resetting thermal cut-outs
(IEC 60335-2-40): ............................................ 300

N/A

- timers: ............................................................. 3000

N/A

- energy regulators: ....................................... 10 000

N/A

- thermostats which control motor-compressor
(IEC 60335-2-40): ..................................... 100 000

N/A

- motor-compressor starting relays (IEC 60335-2-40):
................................................................... 100 000

N/A

- automatic thermal motor-protectors for hermetic and
semi-hermetic type motor-compressors (not less than
number of operations during locked rotor test)
(IEC 60335-2-40): ................................... min 2000

N/A

- manual reset thermal motor-protectors for hermetic
and semi-hermetic type motor-compressors
(IEC 60335-2-40): .............................................. 50

N/A

TRF No. IEC60335_2_40F

Page 15 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

Requirement + Test
- other automatic thermal motor-protectors
(IEC 60335-2-40): .......................................... 2000

Result
Protector for fan motors

Verdict
P

- other manual reset thermal motor-protectors
(IEC 60335-2-40): .............................................. 30

N/A

Thermal motor protectors are tested in combination
with their motor under the conditions specified in
annex D (IEC 60335-1/A1)

N/A

For water valves containing live parts and that are
incorporated in external hoses for connection of an
appliance to the water mains, the degree of protection
declared for subclause 6.5.2 of IEC 60730-2-8 is IPX7
(IEC 60335-1/A1)

N/A

Appliance couplers complying with IEC 60320-1

N/A

However, appliances classified higher than IPX0, the
appliance couplers complying with IEC 60320-2-3
(IEC 60335-1/A1)

N/A

Interconnection couplers complying with IEC 60320-2-2

N/A

24.1.6

Small lamp holders similar to E10 lampholders
complying with IEC 60238, the requirements for E10
lampholders being applicable

N/A

24.1.7

Remote operation of appliance via telecommunication
network, relevant standard for telecommunication
interface circuitry in appliance is IEC 62151
(IEC 60335-1/A2)

N/A

24.1.8

Standard for thermal links IEC 60691 (IEC 60335-1/A2)

N/A

Thermal links not complying with IEC 60691
considered to be an intentionally weak part for
purposes of clause 19 (IEC 60335-1/A2)

N/A

24.1.5

24.1.9

24.2

Relays, other than motor starting relays, tested as part
of appliance (IEC 60335-1/A2)

P

They also tested in accordance with clause 17 of
IEC 60730-1, number of operations in clause 24.1.4
selected according to relay function in the appliance
(IEC 60335-1/A2) .....................................................:

P

No switches or automatic controls in flexible cords

P

No devices causing the protective device in the fixed
wiring to operate in the event of a fault in the appliance

P

No thermal cut-outs that can be reset by soldering

P

24.3

Switches intended for all-pole disconnection of
stationary appliances are directly connected to the
supply terminals and having a contact separation in all
poles, providing full disconnection under
overvoltage category III conditions

N/A

24.4

Plugs and socket-outlets for extra-low voltage circuits
and heating elements, not interchangeable with plugs
and socket-outlets listed in IEC 60083 or IEC 60906-1
or with connectors and appliance inlets complying with
the standard sheets of IEC 60320-1

N/A

TRF No. IEC60335_2_40F

Page 16 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause
24.5

Requirement + Test

Result

Verdict

Capacitors in auxiliary windings of motors marked with
their rated voltage and capacitance and used
accordingly

P

Voltage across capacitors in series with a motor
winding does not exceed 1,1 times rated voltage, when
the appliance is supplied at 1,1 times rated voltage
under minimum load

P

Working voltage of motors connected to the supply
mains and having basic insulation that is inadequate for
the rated voltage of the appliance, not exceeding 42 V

N/A

In addition, the motors are complying with the
requirements of annex I

N/A

24.7

Hose-sets for connection of appliances to the water
mains, complying with IEC 61770 and supplied with the
appliance (IEC 60335-1/A1)

N/A

24.101

Replaceable parts of thermal control devices identified
by marking (IEC 60335-2-40)

N/A

29

CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION

—

Clearances, creepage distances and solid insulation
withstand electrical stress

P

24.6

Coatings used on printed circuits boards to protect
microenvironment (Type 1 coating) or
(IEC 60335-1/A2)

N/A

to provide basic insulation (Type 2 coating), annex J
applies (IEC 60335-1/A2)

N/A

Microenvironment is pollution degree 1 under Type 1
coating (IEC 60335-1/A2)

N/A

No clearance or creepage distance requirements under
Type 2 coating (IEC 60335-1/A2)

N/A

For motor-compressor complies with IEC 60335-2-34,
parts related not checked (IEC 60335-2-40)
For motor-compressor not complying with
IEC 60335-2-34, additions and modifications as
specified (IEC 60335-2-40)
29.1

Clearances not less than the values specified in
table 16, taking into account the rated impulse voltage
for overvoltage categories of table 15, unless
(IEC 60335-1/A1)
for basic insulation and functional insulation, they
comply with the impulse voltage test of clause 14
(IEC 60335-1/A1)
However, if construction is affected by wear, distortion,
movement of the parts or during assembly, the
clearances for rated impulse voltages of 1 500 V and
above are increased by 0,5 mm and the impulse
voltage test is not applicable (IEC 60335-1/A1)

TRF No. IEC60335_2_40F

P
N/A

P

N/A

P

Page 17 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

Requirement + Test

Result

Impulse voltage test not applicable (IEC 60335-1/A1):

—

- when the microenvironment is pollution degree 3
(IEC 60335-1/A1)

P

- for basic insulation of class 0 and class 0I appliances
(IEC 60335-1/A1)

N/A

Appliances are in overvoltage category II
Compliance is checked by inspection and
measurements as specified
29.1.1

Verdict

Clearances of basic insulation withstand the
overvoltage, taking into account the rated impulse
voltage
Clearance at the terminals of tubular sheathed heating
elements may be reduced to 1 mm if the
microenvironment is pollution degree 1

P
(See appended table)

P
P

N/A

Lacquered conductors of windings considered to be
bare conductors (IEC 60335-1/A1)

P

29.1.2

Clearances of supplementary insulation not less than
those specified for basic insulation in table 16

P

29.1.3

Clearances of reinforced insulation not less than those
specified for basic insulation in table 16, but using the
next higher step for rated impulse voltage

P

29.1.4

For functional insulation, the values of table 16 are
applicable, unless

P

the appliance complies with clause 19 with the
functional insulation short-circuited

29.1.5

N/A

Lacquered conductors of windings considered to be
bare conductors (IEC 60335-1/A1)

P

However, clearances at crossover points are not
measured

P

Clearance between surfaces of PTC heating elements
may be reduced to 1 mm

N/A

Lacquered conductors of windings assumed to be bare
conductors, but the clearances specified in table 16 are
reduced by 0,5 mm for rated impulse voltages of at
least 1500 V

P

Appliances having higher working voltage than rated
voltage, the voltage used for determining clearances
from table 16 is the sum of the rated impulse voltage
and the difference between the peak value of the
working voltage and the peak value of the rated voltage

P

If the secondary winding of a step-down transformer is
earthed, or if there is an earthed screen between the
primary and secondary windings, clearances of basic
insulation on the secondary side not less than those
specified in table 16, but using the next lower step for
rated impulse voltage

N/A

TRF No. IEC60335_2_40F

Page 18 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

Requirement + Test

Result

Circuits supplied with a voltage lower than rated
voltage, clearances of functional insulation based on
the working voltage used as the rated voltage in
table 15
29.2

N/A

Creepage distances not less than those appropriate for
the working voltage, taking into account the material
group and the pollution degree
Pollution degree 2 applies, unless

P

For PCB of indoor unit only

precautions taken to protect the insulation;
pollution degree 1
insulation subjected to conductive pollution;
pollution degree 3

P
N/A

For parts except PCB of indoor
unit

P

Compliance is checked by inspection and
measurements as specified

P

Insulation located in airflow, pollution degree 3 unless
(IEC 60335-2-40)

P

insulation enclosed or located so that unlikely to be
exposed to pollution due to normal use
(IEC 60335-2-40)
29.2.1

Verdict

Creepage distances of basic insulation not less than
specified in table 17
For pollution degree 1, creepage distance not less than
the minimum specified for the clearance in table 16, if
the clearance has been checked according to the test
of clause 14

For PCB of indoor unit only

P

P
N/A

29.2.2

Creepage distances of supplementary insulation at
least as specified for basic insulation in table 17

P

29.2.3

Creepage distances of reinforced insulation at least
double as specified for basic insulation in table 17

P

29.2.4

Creepage distances of functional insulation not less
than specified in table 18

P

Creepage distances may be reduced if the appliance
complies with clause 19 with the functional insulation
short-circuited

N/A

30

RESISTANCE TO HEAT AND FIRE

—

30.1

External parts of non-metallic material,

P

parts supporting live parts, and

P

thermoplastic material providing supplementary or
reinforced insulation,

P

sufficiently resistant to heat

P

Ball-pressure test according to IEC 60695-10-2

P

External parts: at 40 °C plus the maximum temperature
rise determined during the test of clause 11, or at
75 °C, whichever is the higher; temperature (°C)....:

P

TRF No. IEC60335_2_40F

Page 19 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

30.2

Requirement + Test

P

Parts of thermoplastic material providing
supplementary or reinforced insulation, 25 °C plus the
maximum temperature rise determined during
clause 19, if higher; temperature (°C) ......................:

N/A

Parts of non-metallic material adequately resistant to
ignition and spread of fire

P

Requirement does not apply to decorative trims, knobs
and other parts unlikely to be ignited or to propagate
flames that originate inside the appliance

P

Compliance checked by test of clause 30.2.1. In addition:

—

- unattended appliances, clause 30.2.3 applies
Appliances for remote operation, clause 30.2.3 applies
(IEC 60335-1/A2)

30.2.3

N/A
P
N/A

Base material of printed circuit board, clause 30.2.4
applies

P

Glow-wire test of IEC 60695-2-11 at 550 C, unless

P

material is classified at least HB40 according to
IEC 60695-11-10 (IEC 60335-1/A2)

N/A

Parts for which the glow-wire test cannot be carried out
meet the requirements in ISO 9772 for category HBF
material (IEC 60335-1/A1)

N/A

Appliances operated while unattended, tested as
specified in 30.2.3.1 and 30.2.3.2
Test not applicable to conditions as specified

30.2.3.1

Verdict

Parts supporting live parts: at 40 °C plus the maximum
temperature rise determined during the test of
clause 11, or at 125 °C, whichever is the higher;
temperature (°C).......................................................:

- attended appliances, clause 30.2.2

30.2.1

Result

P
N/A

Parts of non-metallic material supporting connections
carrying a current exceeding 0,2 A during normal
operation, and (IEC 60335-1/A2)

P

parts of non-metallic material within a distance of
3 mm, (IEC 60335-1/A2)

P

subjected to glow-wire test of IEC 60695-2-11 with a
test severity of 850 °C (IEC 60335-1/A2)

P

However, glow-wire test not carried out on parts of
material classified as having a glow-wire flammability
index of at least 850 C according to IEC 60695-2-12
(IEC 60335-1/A2)

N/A

Glow-wire flammability index only used if in specified
range of thickness (IEC 60335-1/A2)

N/A

Glow-wire test not carried out on small parts comply
with needle-flame test of annex E or on small parts of
material classified as V-0 or (IEC 60335-1/A2)

N/A

V-1 according to IEC 60695-1-10 (IEC 60335-1/A2)

N/A

TRF No. IEC60335_2_40F

Page 20 of 41

Report No. GZES120900879606

IEC 60335-2-40
Clause

30.2.3.2

Requirement + Test

Result

Classified V-0 or V-1 material only used if in specified
range of thickness (IEC 60335-1/A2)

N/A

Test as specified for an interposed shielding material
(IEC 60335-1/A2)

N/A

Parts of non-metallic material supporting
current-carrying connections, and (IEC 60335-1/A2)

P

parts of non-metallic material within a distance of
3 mm, (IEC 60335-1/A2)

P

subjected to glow-wire test of IEC 60695-2-11

P

However, glow-wire test not carried out on material
having a glow-wire ignition temperature according to
IEC 60695-2-13 of at least:
Glow-wire test of IEC 60695-2-11, the temperature being:

N/A

—

- 775 °C, for connections carrying a current exceeding
0,2 A during normal operation

N/A

- 675 °C, for other connections

N/A

Glow-wire ignition temperature only used if in specified
range of thickness (IEC 60335-1/A2)

N/A

Test as specified for an interposed shielding material
(IEC 60335-1/A2)

N/A

When glow-wire test of IEC 60695-2-11 carried out, temperatures are:

30.2.4

Verdict

—

- 750 °C, for connections carrying a current exceeding
0,2 A during normal operation

N/A

- 650 °C, for other connections

N/A

If a flame persists longer than 2 s during test, then
these parts and adjacent parts further subjected to
needle-flame test of annex E, unless (IEC 60335-1/A1
corr.1)

N/A

material is classified as V-0 or V-1 according to
IEC 60695-11-10 (IEC 60335-1/A2)

N/A

Classified V-0 or V-1 material only used if in specified
range of thickness (IEC 60335-1/A2)

N/A

Base material of printed circuit boards subjected to
needle-flame test of annex E (IEC 60335-1/A2)

P

Test not carried out by specified items ....................:

N/A

TRF No. IEC60335_2_40F

Page 21 of 41

Report No. GZES120900879606

IEC 60335-2-40
10.1

P

TABLE: Power input deviation
P rated (W)

P measured (W)

P

Required P

230 V, 50 Hz

1300

1078,9

-17,0%

+15%

GWH09MB-K3DNC1K
(Cooling mode)

230 V, 50 Hz

1400

519,8

-62,9%

+15%

GWH09MB-K3DNC1K
(Heating mode)

230 V, 50 Hz

1400

1247,9

-10,9%

+15%

GWH12MB-K3DNC1K
(Cooling mode)

230 V, 50 Hz

1550

522,8

-66,3%

+15%

GWH12MB-K3DNC1K
(Heating mode)

Input deviation
of/at:

Remark

Supplementary information:
The data listed in the table were the maximum measured values for the test samples assembled with all
alternative fan motors.
11.8

TABLE: Heating test, thermocouples

(GWH09MB-K3DNC1K)

P

Tested voltage ..........................................................: 240 V x 1,06 = 254,4 V

—

Ambient, t (°C) ..........................................................: Cooling mode:
Indoor: DB: 32, WB: 23;
Outdoor: DB: 43, WB: 26

—

Heating mode:
Indoor: DB: 27, WB: Outdoor: DB: 24, WB: 18
Thermocouple locations

T (°C)
Cooling

Max. T (°C)
Heating

Indoor unit
Power cord

39,0

33,4

75

Plastic enclosure

31,8

27,2

For clause 30.1

Terminal block

33,5

27,9

85

Swing motor
Indoor fan motor enclosure

33,5

35,1

90 (Class A)

40,6

36,2

105 (Class E)

Main PCB

34,2

30,2

145

High frequency transformer

43,9

41,2

105 (Class E)

Fan motor running capacitor

37,9

33,4

T70

Relay for compressor

36.8

33.0

T50

Relay for fan motor

37,2

33,1

T85

Outdoor unit
Interconnection cord

43,3

24,1

75

Terminal block

44,0

24,4

85

Lead wiring for compressor

57,4

34,1

75

Compressor housing

86,8

61,5

For reference

Discharge pipe of compressor

89,0

62,2

For reference

TRF No. IEC60335_2_40F

Page 22 of 41

Report No. GZES120900879606

IEC 60335-2-40
Outdoor fan motor winding
(FW30J-ZL NIDEC SHIBAURA)

71,2

23,3

105 (Class E)

4-way valve winding

58,7

73,0

110 (Class B)

Reactor winding

51,9

30,4

165 (Class H)

Main PCB

47,6

26,9

145

X capacitor

47,2

23,5

T100

Varistor

42,8

26,4

T85

High frequency transformer

53,7

31,8

105 (Class E)

Relay on main board

51,4

27,3

T70

Test floor

47,3

20,8

90

Supplementary information: ——

11.8

TABLE: Heating test, thermocouples

(GWH12MB-K3DNC1K)

P

Tested voltage ..........................................................: 240 V x 1,06 = 254,4 V

—

Ambient, t (°C) ..........................................................: Cooling mode:
Indoor: DB: 32, WB: 23;
Outdoor: DB: 43, WB: 26

—

Heating mode:
Indoor: DB: 27, WB: Outdoor: DB: 24, WB: 18
Thermocouple locations

T (°C)
Cooling

Max. T (°C)
Heating

Indoor unit
Power cord

32,2

28,2

75

Plastic enclosure

33,2

28,2

For clause 30.1

Terminal block

32,7

28,7

85

Swing motor
Indoor fan motor enclosure

37,4

27,9

90 (Class A)

40,3

37,1

105 (Class E)

Main PCB

32,3

28,6

145

High frequency transformer

43,6

41,2

105 (Class E)

Fan motor running capacitor

36,1

29,6

T70

Outdoor unit
Terminal block

37,2

22,7

85

Lead wiring for compressor

51,0

30,3

75

Compressor housing

87,5

63,2

For reference

Discharge pipe of compressor
Outdoor fan motor winding
(FW30J-ZL Panasonic)
Outdoor fan motor winding
(FW30J-ZL Shinano)

86,6

61,8

For reference

55,0

23,5

105 (Class E)

56,9

25,3

105 (Class E)

4-way valve winding

51,3

73,4

110 (Class B)

TRF No. IEC60335_2_40F

Page 23 of 41

Report No. GZES120900879606

IEC 60335-2-40
Main PCB

50,4

27,5

145

High frequency transformer

59,0

32,9

105 (Class E)

Relay on main board

50,9

28,3

T70

Test floor

48,8

22,4

90

Supplementary information: the recorded values are the max value of alternative fan motor

13.2

P

TABLE: Leakage current
Heating appliances: 1,15 x rated power input .......:





Motor-operated and combined appliances:
1,06 x rated voltage................................................:

240 V x 1,06 = 254,4 V



Leakage current between

I (mA)

Max. allowed I (mA)

L/N and earthed metal enclosure

0,37

3,5

L/N and plastic enclosure of indoor unit

0,08

0,25

L/N and plastic handle of outdoor unit

0,08

0,25

L/N and earthed metal enclosure

0,38

3,5

L/N and plastic enclosure of indoor unit

0,09

0,25

L/N and plastic handle of outdoor unit

0,08

0,25

For model GWH09MB-K3DNC1K

For model GWH12MB-K3DNC1K

Supplementary information:
The data listed in the table were the maximum measured values for the samples assembled with all
alternative fan motors.

13.3

P

TABLE: Electric strength

Test voltage applied between:

Voltage (V)

Breakdown
(Yes/No)

Live parts and earthed metal enclosure

1000

No

Live parts on display board and insulation cover of display board

1750

No

L/N and surface of display panel

3000

No

Supplementary information:
The data listed in the table were the maximum measured values for the samples assembled with all
alternative fan motors.

TRF No. IEC60335_2_40F

Page 24 of 41

Report No. GZES120900879606

IEC 60335-2-40

19.2

P

TABLE: Abnormal operation
Tested voltage

240 V



t1 (C).........................................................................:

23,0



t2 (C).........................................................................:

23,0



Temperature T of part / at:

T (C)

Required T (C)

Outdoor fan motor winding
(FW30J-ZL Panasonic)

93,8

165 (class E)

fan motor enclosure
(FW30J-ZL Panasonic)

85,6

150

Outdoor fan motor winding
(FW30J-ZL Shinano)

28,8

165 (class E)

fan motor enclosure
(FW30J-ZL Shinano)

27,5

150

Outdoor fan motor winding
(FW30J-ZL NIDEC SHIBAURA)

98,6

165 (class E)

fan motor enclosure
(FW30J-ZL NIDEC SHIBAURA)

91,5

150

Remark: ——

24.1

P

TABLE: Components

Object / part No.

Manufacturer/
trademark

Type / model

Technical data

Standard

Mark(s) of
conformity

Indoor unit

Plug

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

Plug
(Alternative)

AC 250 V, 16 A

DIN VDE 0620-1: VDE
2010-02
40006002

Changzhou Hong
Chang
DTIII-2P-05
Electronics Co.,
Ltd.

AC 250 V, 16 A

DIN VDE 0620-1: VDE
2010-02
40015536

Power cord

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H05VV-F

3G 1,5 mm2

DIN VDE 0281-5: VDE
2002-09
40005362

Power cord
(Alternative)

Changzhou Hong
Chang
H05VV-F
Electronics Co.,
Ltd.

3G 1,5 mm2

DIN VDE 0281-5:
VDE 124978
2002-09

TRF No. IEC60335_2_40F

CT-104

Page 25 of 41

Report No. GZES120900879606

IEC 60335-2-40
Power cord
(Alternative for
models
GWH09MBK3DNA2K,
GWH12MBK3DNA2K,
GWH09MBK3DNA5K,
GWH12MBK3DNA5K,
GWH09MBK3DNB3K,
GWH09MBK3DNE1K,
GWH09MBK3DNC9K,
GWH09MBK3DNA4K,
GWH12MBK3DNB3K,
GWH12MBK3DNE1K,
GWH12MBK3DNC9K,
GWH12MBK3DNA4K)

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H05VV-F

3G 1,0 mm2

DIN VDE 0281-5: VDE
2002-09
40005362

Power cord
(Alternative for
models
GWH09MBK3DNE2K,
GWH09MBK3DNE3K,
GWH12MBK3DNE2K,
GWH12MBK3DNE3K)

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H05VV-F

3G 1,0 mm2

DIN VDE 0281-5: VDE
2002-09
40005362

Power cord
(Alternative for
models
GWH09MBK3DNB7K,
GWH09MBK3DNC5K,
GWH12MBK3DNB7K,
GWH12MBK3DNC5K)

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H05VV-F

3G 1,0 mm2

DIN VDE 0281-5: VDE
2002-09
40005362

Terminal block

Changzhou
Changheng
Kaidu Electric
Appliances Co.,
Ltd.

AC 250 V, 2,5 mm

EN 60998-1:
2004;
EN 60998-2-1:
2004;
EN 60335-2-40;
EN 60335-1

TRF No. IEC60335_2_40F

JX-G-4C

2

Tested with
appliance
VDE
40020936

Page 26 of 41

Report No. GZES120900879606

IEC 60335-2-40

Terminal block
(Alternative)

Zhen jiang
Honglian
Electrician Co.,
Ltd.

JX1239

AC 250 V, 2,5 mm2

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Tested with
appliance
VDE
40013197

Terminal block
(Alternative)

Nantong
Huaguan Electric JXW-4-G1
Co., Ltd.

AC 250 V, 2,5 mm

EN 60998-1:
2004;
EN 60998-2-1:
2004;
EN 60335-2-40;
EN 60335-1

Swing motor

Changzhou LeiLi
Electrical
MP24AA
Equipment Co.,
Ltd.

12 VDC, Class A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Swing motor
(Alternative)

Jiangsu Huayang
Electrical
MP24AA
Appliance Co.,
Ltd.

12 VDC, Class A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Swing motor
(Alternative)

Changzhou
Oukai Electrical
Appliance Co.,
Ltd.

MP24AA

12 VDC, Class A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Swing motor
(Alternative)

Hefei Rishang
Electrical Co.,
Ltd.

MP24AA

12 VDC, Class A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Swing motor
(Alternative)

Zhongshan
Huilipu Motor
Co., Ltd.

MP24AA

12 VDC, Class A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Indoor fan motor

Jiangsu Shangqi
Group Co., Ltd.

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Indoor fan motor
(Alternative)

Zhongshan
Broad-Ocean
Motor Co., Ltd.

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

FN20J-PG

220-240 V, 50 Hz,
20 W, Class E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

BR Series

AC 250 V, 5 A,
Operation: 100 ℃

EN 60730-1;
EN 60730-2-2

VDE 132813

Indoor fan motor
(Alternative)
Indoor fan motor
(Alternative)
Indoor fan motor
(Alternative)
Indoor fan motor
(Alternative)

Motor protector

Zhuhai Kaibang
Motor
Manufacture Co.,
Ltd.
Changzhou
Regal-Beloit
Sinya Motor Co.,
Ltd.
Zhejiang Wolong
Home Appliance
Motor Co., Ltd.
Zhuhai City
Tongde Electric
Equipment Co.,
Ltd.
Jiangsu
Changsheng
Electric
Appliance Co.,
Ltd.

TRF No. IEC60335_2_40F

2

Page 27 of 41

Report No. GZES120900879606

IEC 60335-2-40

Motor protector
(Alternative)

Changzhou
Changhong
Tongli Electric
Appliance Co.,
Ltd.

KW Series

AC 250 V, 8 A,
Operation: 100℃

EN 60730-1;
EN 60730-2-2

VDE
40020906

Motor protector
(Alternative)

Sensata
Technologies
Holland B.V.

BRL Series

AC 250 V, 8 A;
Operation: 100℃

EN 60730-1;
EN 60730-2-2

KEMA
2089558.01

Main board
for models other
than GWH12MBK3DND8D,
GWH09MBK3DND8D

Gree Electric
Appliances, Inc.
of Zhuhai

M839F2PJ

—

EN 60335-2-40;
EN 60335-1

Tested with
appliance

- Indoor fan
motor running
capacitor

Wuxi Xixi
Capacitor Co.,
Ltd.

CBB61

AC 500 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50128479

- Indoor fan
motor running
capacitor
(Alternative)

Zhuhai Gree
Xinyuan
Electronic Co.,
Ltd.

CBB61

AC 500 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50120798

- Indoor fan
motor running
capacitor
(Alternative)

Xiamen
Faratronic Co.,
Ltd.

CBB61

AC 500 V, 1,0 uF,
T70

EN 60252-1:
2001

VDE
40004094

- Indoor fan
motor running
capacitor
(Alternative)

Ningbo Shine
Electronical Co.,
Ltd.

CBB61A

AC 500 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50065558

- Indoor fan
motor running
capacitor
(Alternative)

AnHui FeiDa
Industry Stock
Co., Ltd.

CBB61

AC 450 V, 1 uF, T85

EN 60252-1:
2001

VDE
40012579

- Indoor fan
motor running
capacitor
(Alternative)

Shanghai Haoye
Capacitors Co., MKNS105
Ltd.

AC 450 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50035566

- Indoor fan
motor running
capacitor
(Alternative)

Foshan Shunde
Fongming
Electronic Tech.
Co., Ltd.

CBB61

AC 450 V, 1,0 uF,
T70

EN 60252-1:
2001

VDE
40006835

Main board
for models
GWH12MBK3DND8D,
GWH09MBK3DND8D

Gree Electric
Appliances, Inc.
of Zhuhai

M839F2GJ

—

EN 60335-2-40;
EN 60335-1

Tested with
appliance

TRF No. IEC60335_2_40F

Page 28 of 41

Report No. GZES120900879606

IEC 60335-2-40
- Indoor fan
motor running
capacitor

Ningbo Shine
Electrical Co.,
Ltd.

- Indoor fan
motor running
capacitor
(Alternative)

AC 450 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50076953

Shanghai Haoye
Capacitors Co., MKPS105
Ltd.

AC 450 V, 1,0 uF,
T70

EN 60252-1:
2001

TUV
R50035566

X2 capacitor 1#

Xiamen
Faratronic Co.,
Ltd.

MKP62

AC 275 V, 104M,
T110

EN 132400
EN 60384-14

VDE
40000358

X2 capacitor 1#
(Alternative)

OKAYA Electric
Industries Co.,
Ltd.

LE104

AC 275 V, 0,1 uF,
T100

EN 132400
EN 60384-14

SEMKO
SE/0142-1

MKP

AC 275 V, 0,1 uF,
T100

EN 60384-14:
2005-08

VDE
40024537

MKP62

AC 275 V, 105K,
T110

EN 132400;
EN 60384-14

VDE
40000358

X2 capacitor 1#
(Alternative)
X2 Capacitor 2#

Anhui Xinyang
electronics Co.,
Ltd.
Xiamen
Faratronic Co.,
Ltd.

CBB61S

X2 Capacitor 2#
(Alternative)

Pilkor Electronics
PCX2 335M
Co., Ltd.

AC 275 V, 1,0 uF,
T85

EN 132400;
EN 60384-14

SEMKO
SE/0256-2

X2 Capacitor 2#
(Alternative)

Anhui Xinyang
Electronics Co.,
Ltd.

AC 275 V, 1,0 uF,
T100

EN 60384-14:
2005-08

VDE
40024537

MKP

IEC 61051-1
IEC 61051-2
IEC 61051-2-2
CECC 42000/A1
CECC 42200/A1
CECC 42201/A1
IEC 61051-1
IEC 61051-2
IEC 61051-2-2
CECC 42000
CECC 42200
CECC 42201

Varistor

Chengdu Tieda
Electroni Co.,
Ltd.

MYN15-621K AC 385 V, T85

Varistor
(Alternative)

Xianhua
Advanced
Technology
Holding) Co.,
Ltd.

FNR-14K621 AC 380 V, T85

Optocoupler 1#

Toshiba
Corporation

TLP781

Vceo: 80 V; If: 60
mA; Ic: 50 mA

DIN EN 60747-5- VDE
2: 2003
40021173

Optocoupler 2#

Sharp
Corporation

PC817

Vceo: 80 V; If: 50
mA; Ic: 50 mA

DIN EN 60747-5- VDE
2: 2003
40008087

High frequency
transformer

Xinji Electronics
Component
EE25-9PA
(HangZhou) Co.,
Ltd.

High-frequency
transformer
(Alternative)

Huizhou Jiayang
Electronic New- EE25-9PA
tech Co., Ltd.

TRF No. IEC60335_2_40F

Input: 80 V-260 V,
65KHz, 1,26Ω;
Output: 18 V, 100
mA; 12 V 500 mA;
5 V, 500 mA;
Class E
Input: 85 V-265 V,
65 KHz, 1,26Ω;
Output: 18 V, 100
mA; 12 V, 500 mA;
5 V, 500 mA;
Class B

VDE
40008571

VDE
40008242

EN 60335-2-40;
EN 60335-1

Tested with
appliance

EN 60335-2-40;
EN 60335-1

Tested with
appliance

Page 29 of 41

Report No. GZES120900879606

IEC 60335-2-40

High-frequency
transformer
(Alternative)

Dongguan
Dazhong
Electronic Co.,
Ltd.

EE25-9PA

High-frequency
transformer
(Alternative)

Shenzhen
Jingquanhua
Electronic Co.,
Ltd.

EE25-9PA

Hangzhou
Ruichuang
Inductance
Industry And
Trade Co., Ltd.
Xinji Electronics
Inductance
Component
(Alternative)
(Hangzhou) Co.,
Ltd.
Shenzhen
Inductance
Yamaxi
(Alternative)
Electronic Co.,
Ltd.
Huizhou Jiayang
Inductance
Electronic New(Alternative)
tech Co., Ltd.
Fenghua
Advanced
Inductance
Technology
(Alternative)
(Holding) Co.,
Ltd.
Dongguan
Inductance
Dazhong
(Alternative)
Electronic Co.,
Ltd.
Xinji Electronics
Component
Filter
(Hangzhou) Co.,
Ltd.
Shenzhen
Yamaxi
Filter (Alternative)
Electronic Co.,
Ltd.
Dongguan
Dazhong
Filter (Alternative)
Electronic Co.,
Ltd.

Input: 85 V-265 V,
65 KHz, 1,26Ω;
Output: 18 V, 100
mA; 12 V, 500 mA;
5 V, 500 mA;
Class B
Input: 85 V-265 V,
65 KHz, 1,26Ω;
Output: 18 V, 100
mA; 12 V, 500 mA;
5 V, 500 mA; Class
E

EN 60335-2-40;
EN 60335-1

Tested with
appliance

EN 60335-2-40;
EN 60335-1

Tested with
appliance

200uH/2A

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

200uH/2A

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

T50-26

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

200uH/2A

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

200uH/2A

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

200uH/2A

200 uH, 2 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

SF2022A05220

AC 250 V, 0,5 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

SF2022A05220

AC 250 V, 0,5 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

SF2022A052
AC 250 V, 0,5 A
20

EN 60335-2-40;
EN 60335-1

Tested with
appliance

EN 61810-1:
2004;
IEC 61810-1:
2004

VDE
40024142

Relay for
compressor

Xiamen Hongfa
Electroacoustic
Co., Ltd.

JQX-102F

250 V~; 20 A; T85;
DC 12 V; cycles:
10E4

Relay for
compressor
(Alternative)

Omron
Electronic
Components
(Shenzhen) Ltd.

G4A-1A-ECN

250 V~; 20 A; T85;
DC 12 V; cycles:
10E4

EN 61810-1:
2008

TUV
R50214482

Relay for
compressor
(Alternative)

Omron
Corporation

G4A-1A-ECN

250 V~; 20 A; T50;
DC 12 V; cycles:
10E4

EN 61810-1
EN 60255-23

VDE 107293

TRF No. IEC60335_2_40F

Page 30 of 41

Report No. GZES120900879606

IEC 60335-2-40

Relay for
compressor
(Alternative)

Dongguan
Sanyou
Electrical
Appliances Co.,
Ltd.
Songchuan
Precision Co.,
Ltd.

Relay for
compressor
(Alternative)

Tyco Electronics
(Shenzhen) Co.
Ltd.

EF00-1A2D012-F

Relay for indoor
fan motor

Xiamen Hongfa
Electroacoustic
Co., Ltd.

JZC-43F

Relay for indoor
fan motor
(Alternative)

Omron
Corporation

G5NB-1A

Relay for
compressor
(Alternative)

SFK-112DM

250 V~; 20 A; T85;
DC 12 V; cycles:
10E4

EN 61810-1:
2004
IEC 61810-1:
2004

VDE
40007481

891WP-1A-C

250 V~; 25 A; T85;
DC 12 V; cycles:
10E4

EN 61810-1:
2004

TÜV
R3-50003966

250 V~;20 A; T85;
DC 12 V; cycles:
10E4

EN 61810-1:
2004;
IEC 61810-1:
2003

TUV
R50117320

EN 61810-1
EN 60255-23

VDE
40002220

EN 61810-1
EN 60255-23

VDE 137575

277 VAC, 5 A,
12 VDC, cycles:
10E4, T85

EN 61810-1:
2004

TUV
R50138320

250 VAC, 5 A, 12
VDC, cycles: 3E4,
T85

EN 61810-1
EN 60255-23

VDE
40008369

EN 61810-1
EN 60255-23

VDE
40009151

250 VAC, 3 A, 12
VDC, cycles: 10E4,
T85
250 VAC, 3 A,
12 VDC, cycles:
10E4, T85

Relay for indoor
fan motor
(Alternative)

Dongguan
Sanyou Electrical SRB-SAppliances Co., 112DM
Ltd.
Songchuan
Precision Co.,
202N-1AC-C
Ltd.

Relay for indoor
fan motor
(Alternative)

Tyco Electronics
(Shenzhen) Co.,
Ltd.

250 VAC, 3 A, 12
PCJ-112D3M VDC, cycles: 10E4,
T90

Optical isolator

Panasonic
Electric Works
Co., Ltd.

AQH2223

Fuse link

Hollyland
50T
Company Limited

AC 250 V, T 3,15
AL

EN 60127-1:
1991+A1+A2;
EN 60127-2:
2003+A1

VDE
40014460

Fuse link
(Alternative)

Suzhou Walter
Electronic Co.,
Ltd.

TSD

AC 250 V, T 3,15
AL

EN 60127-1:
1991+A1+A2;
EN 60127-2:
2003+A1

VDE
40016851

NC 80

AC 600 V, 1,5 A

EN 60335-2-40;
EN 60335-1

Tested with
appliance

CCP-508U

CEM-1, 94V-0

EN 60335-2-40
EN 60335-1

S3116

CEM-1, 94V-0

EN 60335-2-40
EN 60335-1

S1141

FR-4, 94V-0

EN 60335-2-40;
EN 60335-1

S3110

CEM-1, 94V-0

EN 60335-2-40
EN 60335-1

KB3151C

FR-1, 94V-0

EN 60335-2-40
EN 60335-1

Relay for indoor
fan motor
(Alternative)

Rectifier
PCB 1#
PCB 1#
(Alternative)
PCB 1#
(Alternative)
PCB 1#
(Alternative)
PCB 1#
(Alternative)

Shindengen
Electric MFG
Co., Ltd.
CHANG CHUN
PLASTICS CO
LTD
SHENGYI
TECHNOLOGY
CO LTD
SHENGYI
TECHNOLOGY
CO LTD
SHENGYI
TECHNOLOGY
CO LTD
KINGBOARD
LAMINATES
LTD

TRF No. IEC60335_2_40F

250 VAC, 0,9A, T85 EN 60950: 2000

VDE
40004928

Tested with
appliance
UL E108591
Tested with
appliance
UL E109769
Tested with
appliance
UL E109769
Tested with
appliance
UL E109769
Tested with
appliance
UL E123995

Page 31 of 41

Report No. GZES120900879606

IEC 60335-2-40

PCB 2#
PCB 2#
(Alternative)
PCB 2#
(Alternative)

PCB 2#
(Alternative)

Cold plasma
generator

SHENGYI
TECHNOLOGY
CO LTD
KINGBOARD
LAMINATES
LTD
SHENGYI
TECHNOLOGY
CO LTD
NAN YA
PLASTICS
CORP CCL
DEPT
ELECTRONIC
MATERIAL DIV
Shandong
Xuesheng
Technology Co.,
Ltd.

Tested with
appliance
UL E109769
Tested with
appliance
UL E123995
Tested with
appliance
UL E109769

S2130

CEM-3, 94V-0

EN 60335-2-40;
EN 60335-1

KB6160

FR-4, 94V-0

EN 60335-2-40;
EN 60335-1

S1141

FR-4, 94V-0

EN 60335-2-40;
EN 60335-1

FR-4-86

FR-4, 94V-0

EN 60335-2-40;
EN 60335-1

Tested with
appliance
UL
E98983(S)

XS-PL-06

AC 220-240 V,
50/60 Hz, ≤ 2 W

EN 60335-1
EN 60335-2-65

TUV
R50172899

Outdoor unit

Interconnection
cord

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H07RN-F

4G 1,5 mm2

DIN VDE 0282-4: VDE
2005-02
40016788

Interconnection
cord
(Alternative for
models
GWH09MBK3DNA2K,
GWH12MBK3DNA2K,
GWH09MBK3DNA5K,
GWH12MBK3DNA5K,
GWH09MBK3DNB3K,
GWH09MBK3DNE1K,
GWH09MBK3DNC9K,
GWH09MBK3DNA4K,
GWH12MBK3DNB3K,
GWH12MBK3DNE1K,
GWH12MBK3DNC9K,
GWH12MBK3DNA4K)

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H07RN-F

4G 1,0 mm2

DIN VDE 0282-4: VDE
2005-02
40016788

TRF No. IEC60335_2_40F

Page 32 of 41

Report No. GZES120900879606

IEC 60335-2-40
Interconnection
cord
(Alternative for
models
GWH09MBK3DNE2K,
GWH09MBK3DNE3K,
GWH12MBK3DNE2K,
GWH12MBK3DNE3K)
Interconnection
cord
(Alternative for
models
GWH09MBK3DNB7K,
GWH09MBK3DNC5K,
GWH12MBK3DNB7K,
GWH12MBK3DNC5K)

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H07RN-F

4G 1,0 mm2

DIN VDE 0282-4: VDE
2005-02
40016788

Guangdong
Huasheng
Electrical
Appliances Co.,
Ltd.

H07RN-F

4G 1,0 mm2

DIN VDE 0282-4: VDE
2005-02
40016788

DC 260-350 V, 15120 Hz, 3Phase,
Class B, R410A

EN 60335-2-34:
2002+A11+A1+A
2;
TUV
EN 60335-1:
R50135262
2002+A1+A11+A
12+A2+A13+A14

Compressor

Zhuhai Landa
QXACompressor Co.,
A091zE190A
Ltd.

Compressor
protector

Sensata
Technoloies
(Baoying) Co.,
Ltd.

Compressor
protector
(Alternative)

Compressor
protector
(Alternative)

Outdoor fan
motor

AC 250 V, 100000
cycles;
1NT11L-6233
Open: (115±3)℃,
Close: (95±5)℃

Changzhou
Changrong
Electrical
HPC
Appliance Co.,
Ltd.
Jiangsu
Changheng
(Group) Control
KSD
Devices &
Products Co.,
Ltd.
Zhuhai Kaibang
Motor
FW30J-ZL
Manufacture Co.,
Ltd.

EN60730-2-9
EN60730-1

KEMA NO.
2014531.16

AC 250 V, 5 A;
10000 cycles;
Operation: 115℃;
Reset: 95℃

EN 60730-2-9
EN 60730-1

VDE
40032296

AC 250 V, 10 A;
35000 cycles;
Operation: 115℃;
Reset: 95℃

EN 60730-2-9
EN 60730-1

VDE
40022995

DC 176-375 V, 30
W, Class E

EN 60335-2-40
EN 60335-1

Tested with
appliance

Outdoor fan
motor
(Alternative)

Dongguan
Shinano Motor
Co., Ltd.

FW30J-ZL

DC 310 V, 30 W,
Class E

EN 60335-2-40
EN 60335-1

Tested with
appliance

Outdoor fan
motor
(Alternative)

NIDEC
SHIBAURA
(Zhejiang)
CORP

FW30J-ZL

310V,0,36A, 30W,
Class E, 76Ω

EN 60335-2-40
EN 60335-1

Tested with
appliance

TRF No. IEC60335_2_40F

Page 33 of 41

Report No. GZES120900879606

IEC 60335-2-40

Outdoor fan
motor
(Alternative)

Panasonic
Appliances
Motor
FW30J-ZL
(Hangzhou) Co.,
Ltd.

310V, 30W, Class
E, 76Ω

EN 60335-2-40
EN 60335-1

Tested with
appliance

Outdoor fan
motor
(Alternative)

Hefei Shinano
Motor Co., LTD.

FW30J-ZL

310V, 30W, 0,13A,
Class E, 76Ω

EN 60335-2-40
EN 60335-1

Tested with
appliance

4-way valve

Zhejiang Duan
Precision
Industries Group
Co., Ltd.

AC 220-240 V;
DSF-4-R410A 50/60 Hz; 7/5 W;
Class B

EN 60730-1

VDE
40013212

4-way valve
(Alternative)

Zhejiang Sanhua
AC 220-240 V,
Climate and
SHF-4H-23U50/60 Hz, 4,5/3,5 W, EN 60730-1
Appliance
P
Class B
Controls Group
Co., Ltd.

VDE
40003240

Main board
for models
GWH09MBK3DNA3K,
GWH09MBK3DND3K,
GWH09MBK3DNA2K,
GWH09MBK3DNA5K,
GWH09MBK3DNB3K,
GWH09MBK3DNE1K,
GWH09MBK3DNC9K,
GWH09MBK3DNA4K,
GWH09MBK3DNE2K,
GWH09MBK3DNE3K,
GWH09MBK3DND8D,
GWH09MBK3DNB7K,
GWH09MBK3DNC5K,
GWH09MBK3DNC1K,
GWH09MBK3DNC8K

Gree Electric
Appliances, Inc.
of Zhuhai

Tested with
appliance

TRF No. IEC60335_2_40F

W8283BX

—

EN 60335-2-40
EN 60335-1

Page 34 of 41

Report No. GZES120900879606

IEC 60335-2-40
Main board
for models
GWH12MBK3DNA3K,
GWH12MBK3DND3K,
GWH12MBK3DNA2K,
GWH12MBK3DNA5K,
GWH12MBK3DNB3K,
GWH12MBK3DNE1K,
GWH12MBK3DNC9K,
GWH12MBK3DNA4K,
GWH12MBK3DNE2K,
GWH12MBK3DNE3K,
GWH12MBK3DND8D,
GWH12MBK3DNB7K,
GWH12MBK3DNC5K,
GWH12MBK3DNC1K,
GWH12MBK3DNC8K

Gree Electric
Appliances, Inc.
of Zhuhai

Y1 Capacitor

—

EN 60335-2-40
EN 60335-1

Tested with
appliance

TDK-EPC
Corporation,
CD472M
Capacitors Group

AC 250 V, 472M,
T70

EN 60384-14:
2005-08

VDE
40029780

Y1 Capacitor

Murata Mfg. Co.,
Ltd.
KX472M
(Headquarters)

250VAC, 472M

EN 60384-14:
2005-08

VDE
40002831

Y2 Capacitor

TDK-EPC
Corporation,
CS472M
Capacitors Group

AC 250 V, 472M,
T70

EN 60384-14:
2005-08

VDE
40029781

MKP62

AC 275 V, 104M,
T110

EN 132400
EN 60384-14

VDE
40000358

LE104

AC 275 V, 0,1 uF,
T100

EN 132400
EN 60384-14

SEMKO
SE/0142-1

MKP

AC 275 V, 0,1 uF,
T100

EN 60384-14:
2005-08

VDE
40024537

MKP62

AC 275 V, 105K,
T110

EN 132400;
EN 60384-14

VDE
40000358

AC 275 V, 1,0 uF,
T85

EN 132400;
EN 60384-14

SEMKO
SE/0256-2

X2 capacitor 1#
X2 capacitor 1#
(Alternative)
X2 capacitor 1#
(Alternative)

Xiamen
Faratronic Co.,
Ltd.
OKAYA Electric
Industries Co.,
Ltd.
Anhui Xinyang
electronics Co.,
Ltd.

W8283BW

X2 Capacitor 2#

Xiamen
Faratronic Co.,
Ltd.

X2 Capacitor 2#
(Alternative)

Pilkor Electronics
PCX2 335M
Co., Ltd.

TRF No. IEC60335_2_40F

Page 35 of 41

Report No. GZES120900879606

IEC 60335-2-40

X2 Capacitor 2#
(Alternative)

Anhui Xinyang
Electronics Co.,
Ltd.

MKP

AC 275 V, 1,0 uF,
T100

EN 60384-14:
2005-08

VDE
40024537

PTC Resistance

Gaoli Electronic
Branch of
Huagong Tech
Co., Ltd.

MZ8IVB470N

R=47Ω±20%;
Ts=120±10℃ ;
Umax=275VAC;
Imax=8Arms

EN 60335-2-40
EN 60335-1

Tested with
appliance

PTC Resistance
(Alternative)

Dandong
Guotong
Electronic
MZ-47R-A
Components Co.,
Ltd.

R=47(1±20%)

EN 60335-2-40
EN 60335-1

Tested with
appliance

IEC 61051-1
IEC 61051-2
IEC 61051-2-2
CECC 42000/A1
CECC 42200/A1
CECC 42201/A1
IEC 61051-1
IEC 61051-2
IEC 61051-2-2
CECC 42000
CECC 42200
CECC 42201

Varistor

Chengdu Tieda
Electroni Co.,
Ltd.

MYN15-621K AC 385 V, T85

Varistor
(Alternative)

Xianhua
Advanced
Technology
Holding) Co.,
Ltd.

FNR-14K621 AC 380 V, T85

Optocoupler 1#

Toshiba
Corporation

TLP781

Vceo: 80 V; If: 60
mA; Ic: 50 mA

DIN EN 60747-5- VDE
2: 2003
40021173

Optocoupler 2#

Sharp
Corporation

PC817

Vceo: 80 V; If: 50
mA; Ic: 50 mA

DIN EN 60747-5- VDE
2: 2003
40008087

Optocoupler 3#

AVAGO
TECHNOLOGIE
S
MANUFACTURI
NG
(SINGAPORE)
PTE. LTD

HCPL-817

130%
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Modify Date                     : 2013:07:25 09:55:54+08:00
Create Date                     : 2013:07:01 17:15:50+08:00
Metadata Date                   : 2013:07:25 09:55:54+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : Wing_Pan
Title                           : 
Document ID                     : uuid:5f2b1fad-b515-4a21-9e38-0857ca11e3ce
Instance ID                     : uuid:4e5b9791-d7a8-4ab5-8789-cd70386cdfda
Producer                        : Acrobat Distiller 10.1.4 (Windows)
Page Count                      : 43
Author                          : Wing_Pan
EXIF Metadata provided by EXIF.tools

Navigation menu