DC310V COZY2
User Manual: DC310V
Open the PDF directly: View PDF .
Page Count: 43
Download | |
Open PDF In Browser | View PDF |
Test Report issued under the responsibility of: TEST REPORT IEC 60335-2-40 Safety of household and similar electrical appliances Part 2-40: Particular requirements for electrical heat pumps, air conditioners and dehumidifiers Report Reference No. ...................... : GZES120900879606 Date of issue....................................... : 2013-06-26 Total number of pages ........................ 41 CB Testing Laboratory .................... : SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab Guangzhou Address............................................... : 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, Guangdong, China 510663 Applicant's name.............................. : Gree Electric Appliances, Inc. of Zhuhai Address............................................... : Jinji West Road, Qianshan, Zhuhai, Guangdong, China Test specification: Standard ............................................. : IEC 60335-2-40:2002 (4. Edition) + A1:2005 (incl. Corr.1:2006) + A2:2005 with IEC 60335-1:2001 (4. Edition) (incl. Corr.1:2002) + A1:2004 (incl. Corr.1:2005) + A2:2006 (incl. Corr.1:2006) IEC 62233:2005 (1. Edition) Test procedure ................................... : SGS-CSTC Non-standard test method…………..: N/A Test Report Form No. ...................... : IEC60335_2_40F Test Report Form(s) Originator.......... : VDE Testing and Certification Institute Master TRF......................................... : Dated 2009-11 Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Page 2 of 41 Test item description……………….: Report No. GZES120900879606 Split-Type Air-Conditioner Trade Mark……………………………: Manufacturer/Address………………: Same as applicant Factory/Address……………………...: Same as applicant Model/Type reference ........................ : GWH09MB-K3DNA3K (Indoor unit: GWH09MB-K3DNA3K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DND3K (Indoor unit: GWH09MB-K3DND3K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNA2K (Indoor unit: GWH09MB-K3DNA2K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNA5K (Indoor unit: GWH09MB-K3DNA5K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DND8D (Indoor unit: GWH09MB-K3DND8D/I, Outdoor unit: GWH09MB-K3DND8D/O); GWH09MB-K3DNB3K(Indoor unit: GWH09MB-K3DNB3K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNE1K(Indoor unit: GWH09MB-K3DNE1K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNC9K(Indoor unit: GWH09MB-K3DNC9K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNA4K(Indoor unit: GWH09MB-K3DNA4K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNE2K (Indoor unit: GWH09MB-K3DNE2K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNE3K (Indoor unit: GWH09MB-K3DNE3K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNB7K (Indoor unit: GWH09MB-K3DNB7K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNC5K (Indoor unit: GWH09MB-K3DNC5K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNC1K (Indoor unit: GWH09MB-K3DNC1K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH09MB-K3DNC8K (Indoor unit: GWH09MB-K3DNC8K/I, Outdoor unit: GWH09MB-K3DNA3K/O); GWH12MB-K3DNA3K (Indoor unit: GWH12MB-K3DNA3K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DND3K (Indoor unit: GWH12MB-K3DND3K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNA2K (Indoor unit: GWH12MB-K3DNA2K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNA5K (Indoor unit: GWH12MB-K3DNA5K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DND8D (Indoor unit: GWH12MB-K3DND8D/I, Outdoor unit: GWH12MB-K3DND8D/O) GWH12MB-K3DNB3K(Indoor unit: GWH12MB-K3DNB3K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNE1K(Indoor unit: GWH12MB-K3DNE1K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNC9K(Indoor unit: GWH12MB-K3DNC9K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNA4K(Indoor unit: GWH12MB-K3DNA4K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNE2K (Indoor unit: GWH12MB-K3DNE2K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNE3K (Indoor unit: GWH12MB-K3DNE3K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNB7K (Indoor unit: GWH12MB-K3DNB7K/I, Outdoor unit: GWH12MB-K3DNA3K/O); GWH12MB-K3DNC5K (Indoor unit: GWH12MB-K3DNC5K/I, Outdoor TRF No. IEC60335_2_40F Page 3 of 41 Report No. GZES120900879606 unit: GWH12MB-K3DNA3K/O) GWH12MB-K3DNC1K (Indoor unit: GWH12MB-K3DNC1K/I, Outdoor unit: GWH12MB-K3DNA3K/O) GWH12MB-K3DNC8K (Indoor unit: GWH12MB-K3DNC8K/I, Outdoor unit: GWH12MB-K3DNA3K/O) Ratings................................................ : TRF No. IEC60335_2_40F 220-240 V~; 50 Hz; 1, GWH09MB-K3DNA3K, GWH09MB-K3DND3K, GWH09MBK3DNA2K, GWH09MB-K3DNA5K, GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K, GWH09MBK3DNA4K, GWH09MB-K3DNE2K, GWH09MB-K3DNE3K, GWH09MB-K3DNB7K, GWH09MB-K3DNC5K, GWH09MBK3DNC1K, GWH09MB-K3DNC8K: Cooling: 1300 W; Heating: 1400 W; 2, GWH09MB-K3DND8D: Cooling: 1550 W, Heating: 1400 W; 3, GWH12MB-K3DNA3K, GWH12MB-K3DND3K, GWH12MBK3DNA2K, GWH12MB-K3DNA5K, GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MB-K3DNC9K, GWH12MBK3DNA4K, GWH12MB-K3DNE2K, GWH12MB-K3DNE3K, GWH12MB-K3DNB7K, GWH12MB-K3DNC5K, GWH12MBK3DNC1K, GWH12MB-K3DNC8K: Cooling: 1400 W; Heating: 1550 W; 4, GWH12MB-K3DND8D: Cooling: 1600 W; Heating: 1550 W Page 4 of 41 Report No. GZES120900879606 IEC 60335-2-40 Testing procedure and testing location: CB Testing Laboratory: Testing location/ address .........................: Associated CB Laboratory: SGS-CSTC Standards Technical Services Co., Ltd. - E&E Lab Guangzhou 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, Guangdong, China 510663 N/A Testing location/ address .........................: Tested by (name + signature) .......: Approved by (+ signature) .............: Testing procedure: TMP Tested by (name + signature) .......: George Gu Approved by (+ signature) ..............: Gaven Deng Testing location/ address .........................: Testing procedure: WMT Gree Electric Appliances, Inc. of Zhuhai Jinji West Road, Qianshan, Zhuhai, Guangdong, China N/A Tested by (name + signature) .......: Witnessed by (+ signature) ............: Approved by (+ signature) .............: Testing location/ address .........................: Testing procedure: SMT N/A Tested by (name + signature) .......: Approved by (+ signature) ..............: Supervised by (+ signature) ..........: Testing location/ address .................. : Testing procedure: RMT Tested by (name + signature) .......: Approved by (+ signature) ..............: Supervised by (+ signature) ..........: Testing location/ address .........................: TRF No. IEC60335_2_40F N/A Page 5 of 41 Report No. GZES120900879606 IEC 60335-2-40 Summary of testing: Tests performed (name of test and test clause): Testing location: Tests according to the following standards were carried out: Tests of clause 10, 11, 13, 19.2, 29 and were carried out at: EN 60335-2-40: 2003 + A11: 2004 + A12: 2005 + A1: 2006 + A2: 2009 + A13: 2012; EN 60335-1: 2002 + A11: 2004 + A1: 2004 + A12: 2006 + A2: 2006 + A13: 2008 + A14: 2010 + A15: 2011; EN 62233: 2008 Gree Electric Appliances, Inc. of Zhuhai Jinji West Road, Qianshan, Zhuhai, Guangdong, China Other clauses were carried out at CBTL. Tests of clause 10, 11, 13, 19.2, 24, 29 and 30 were conducted on model GWH09MB-K3DNC1K, GWH12MB-K3DNC1K. The submitted samples complied with above standards. Summary of compliance with National Differences: European group differences had been taken into account. Copy of marking plate: Labels for model GWH09MB-K3DNC1K: TRF No. IEC60335_2_40F Page 6 of 41 IEC 60335-2-40 Labels for model GWH09MB-K3DNC8K: Labels for model GWH12MB-K3DNC1K: TRF No. IEC60335_2_40F Report No. GZES120900879606 Page 7 of 41 IEC 60335-2-40 Labels for model GWH12MB-K3DNC8K: TRF No. IEC60335_2_40F Report No. GZES120900879606 Page 8 of 41 Report No. GZES120900879606 IEC 60335-2-40 Test item particulars .................................................. : Classification of installation and use ............................ : Fixed appliance Supply Connection ....................................................... : Non-detachable flexible cord fitted with a plug ...................................................................................... : Possible test case verdicts: - test case does not apply to the test object ................. : N/A - test object does meet the requirement ....................... : P (Pass) - test object does not meet the requirement ................. : F (Fail) Testing .......................................................................... : Date of receipt of test item ............................................ : 2013-04-20 Date (s) of performance of tests ................................... : From 2013-04-20 to 2013-06-20 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. This document is issued by the company under its General Conditions of Service accessible at http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated: (a) the results shown in this document refer only to the sample(s) tested and (b) such sample(s) are retained for 3 months. This document cannot be reproduced except in full, without prior approval of the company. The test report includes the following additional documents to the original TRF: Attachment I: 2 pages of photo documentation; Attachment II: 1 page of equipment list for TMP General product information: Split-type air-conditioner for household used only, the refrigerant is R410A. The appliances have cooling and heating functions. Model GWH09MB-K3DNA3K is all the same as model GWH12MB-K3DNA3K except for mass of refrigerant, rating labels and programme of outdoor unit main board. Model GWH09MB-K3DND3K is all the same as model GWH09MB-K3DNA3K except for display panel of indoor unit. Model GWH12MB-K3DND3K is all the same as model GWH12MB-K3DNA3K except for display panel of indoor unit. Amendment-1: The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Dec. 12, 2012 to include the following additions, which were considered technical modifications: 1, Added six models: GWH09MB-K3DNA2K, GWH09MB-K3DNA5K, GWH09MB-K3DND8D, GWH12MBK3DNA2K, GWH12MB-K3DNA5K, GWH12MB-K3DND8D. TRF No. IEC60335_2_40F Page 9 of 41 Report No. GZES120900879606 IEC 60335-2-40 The differences between new models and original models were listed as below: 1) Models GWH09MB-K3DNA2K and GWH09MB-K3DNA5K were all same as original model GWH09MB-K3DNA3K except for the appearance of indoor unit display panel. 2) Model GWH09MB-K3DND8D was all the same as original model GWH09MB-K3DNA3K except for the appearance of indoor unit display panel, indoor unit main board and rated power input of cooling mode. (The indoor unit main board of model GWH09MB-K3DND8D was all the same as model GWH09MBK3DNA3K except for the indoor fan motor running capacitor on main board.) 3) Models GWH12MB-K3DNA2K and GWH12MB-K3DNA5K were all same as original model GWH12MB-K3DNA3K except for the appearance of indoor unit display panel. 4) Model GWH12MB-K3DND8D was all the same as original model GWH12MB-K3DNA3K except for the appearance of indoor unit display panel, indoor unit main board and rated power input of cooling mode. (The indoor unit main board of model GWH12MB-K3DND8D was all the same as model GWH12MBK3DNA3K except for the indoor fan motor running capacitor on main board.) 2, Alternative power cord and interconnection cord for models GWH09MB-K3DNA2K, GWH09MB-K3DNA5K, GWH12MB-K3DNA2K, GWH12MB-K3DNA5K. Details see the table 24.1. After reviewing, test of clause 30 was considered to carry out on the alternative fan motor running capacitors. Amendment-2: The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Dec. 28, 2012 to include the following additions, which were considered technical modifications: 1, Added eight models: GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K, GWH09MBK3DNA4K, GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MB-K3DNC9K, GWH12MB-K3DNA4K. The differences between new models and original models were listed as below: 1) Models GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K and GWH09MBK3DNA4K were all same as original model GWH09MB-K3DNA3K except for the appearance of indoor unit display panel. 2) Models GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MB-K3DNC9K and GWH12MBK3DNA4K were all same as original model GWH12MB-K3DNA3K except for the appearance of indoor unit display panel. 2, Alternative power cord and interconnection cord for models GWH09MB-K3DNB3K, GWH09MB-K3DNE1K, GWH09MB-K3DNC9K, GWH09MB-K3DNA4K, GWH12MB-K3DNB3K, GWH12MB-K3DNE1K, GWH12MBK3DNC9K and GWH12MB-K3DNA4K. Details see the table 24.1. 3, Alternative a panel for model GWH09MB-K3DNA2K and GWH12MB-K3DNA2K. After reviewing, no test was considered to carry out. Amendment-3: The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Jan. 21, 2013 to include the following additions, which were considered technical modifications: 1, Added four new models: GWH09MB-K3DNE2K, GWH09MB-K3DNE3K, GWH12MB-K3DNE2K, GWH12MB-K3DNE3K. The differences between new models and original models were listed as below: 1) Model GWH09MB-K3DNE2K was all the same as original model GWH09MB-K3DNA3K except for the appearance of indoor unit display panel and the shape of display board. 2) Model GWH09MB-K3DNE3K was all the same as original model GWH09MB-K3DNA3K except for the appearance of indoor unit display panel. 3) Model GWH12MB-K3DNE2K was all the same as original model GWH12MB-K3DNA3K except for the appearance of indoor unit display panel and the shape of display board. 4) Model GWH12MB-K3DNE3K was all the same as original model GWH12MB-K3DNA3K except for the appearance of indoor unit display panel. 2, Alternative one panel for models GWH09MB-K3DND8D and GWH12MB-K3DND8D. 3, Alternative power cord and interconnection cord for the four new models. Details see the components in bold in table 24.1. After reviewing, no test was considered to be carried out. TRF No. IEC60335_2_40F Page 10 of 41 Report No. GZES120900879606 IEC 60335-2-40 Amendment-4: The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on April 09, 2013 to include the following additions and changes, which were considered technical modifications: 1, Added four new models: GWH09MB-K3DNB7K, GWH09MB-K3DNC5K, GWH12MB-K3DNB7K, GWH12MB-K3DNC5K. Models GWH09MB-K3DNB7K and GWH09MB-K3DNC5K were all the same as original model GWH09MBK3DNA3K except for the appearance of indoor unit display panel and the shape of display board. Details see attachment I. Models GWH12MB-K3DNB7K and GWH12MB-K3DNC5K were all the same as original model GWH12MBK3DNA3K except for the appearance of indoor unit display panel and the shape of display board. Details see attachment I. 2, Added reactor, interconnection cord, power cord as alternative ones, details see the components in bold in table 24.1. 3, Added chassis electrical heater for models GWH09MB-K3DNA4K, GWH09MB-K3DNA5K, GWH12MBK3DNA4K, GWH12MB-K3DNA5K, details see attachment I and table 24.1. The electrical heater would not work during the appliance normal operation. 4, Updated the label of indoor fan motor. (the current mark on label was corrected from 0,215 A to 0,180 A, detail see attachment I) After reviewing, tests of clause 8, 16.3, 19.10, 22, 24, 25, 29 and 30 were considered to be necessary. Amendment-5: The original test report Ref. No. GZES120900879601, dated Nov. 23, 2012 was modified on Jun 26, 2013 to include the following additions and changes, which were considered technical modifications: 1, Added four new models: GWH09MB-K3DNC1K, GWH09MB-K3DNC8K, GWH12MB-K3DNC1K, GWH12MB-K3DNC8K. Models GWH09MB-K3DNC1K and GWH09MB-K3DNC8K are all the same as original model GWH09MBK3DNA3K except for the appearance of indoor unit display panel. Details see attachment I. Models GWH12MB-K3DNC1K and GWH12MB-K3DNC8K are all the same as original model GWH12MBK3DNA3K except for the appearance of indoor unit display panel. Details see attachment I. There are two colours for indoor unit display panels of models GWH09MB-K3DNC8K and GWH12MBK3DNC8K, Details see attachment I. 2, Added outdoor fan motor, Y1 capacitor as alternative ones, details see the components in bold in table 24.1. After reviewing, tests of clause 10, 11, 13, 19.2, 24, 29 and 30 were considered to be necessary. TRF No. IEC60335_2_40F Page 11 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause Requirement + Test 10 POWER INPUT AND CURRENT 10.1 Power input at normal operating temperature, rated voltage and normal operation not deviating from rated power input by more than shown in table 1 10.2 Result Verdict — (See appended table) P Deviation of appliance with one or more rated voltage ranges (IEC 60335-1/A2) N/A Current at normal operating temperature, rated voltage and normal operation not deviating from rated current by more than shown in table 2 N/A Deviation of appliance with one or more rated voltage ranges (IEC 60335-1/A2) N/A 11 HEATING — 11.1 No excessive temperatures in normal use (IEC 60335-2-40) P Compliance is checked by the tests of annex C, if (IEC 60335-2-40): — 11.2 - temperature of motor winding exceeds values shown in table 3 (IEC 60335-2-40) N/A - there is doubt about classification of insulation system of the motor (IEC 60335-2-40) N/A Placing and mounting of appliance (IEC 60335-2-40): — - clearances to adjacent surfaces (IEC 60335-2-40); P - flow rates for liquid source or sink equipment be minimum, except for fan coils where flow rates and liquid temperatures be maximum (IEC 60335-2-40/A2); N/A - static pressures (IEC 60335-2-40); N/A - means of adjusting the flow, flow for tests be minimum obtainable (IEC 60335-2-40); N/A - adjustable limit controls set at maximum cut-out setting and minimum differential (IEC 60335-2-40). P Appliances with supplementary heaters, use test casing of clause 11.9 (IEC 60335-2-40) N/A 11.2.1 Appliances with supplementary heaters, inlet duct connected to inlet air opening (IEC 60335-2-40) N/A 11.2.2 Appliance without supplementary heaters, air outlet used (IEC 60335-2-40) N/A 11.3 Temperature rise determine by thermocouples or resistance method (IEC 60335-2-40) 11.4 Test performed at supply voltage between 0,94 and 1,06 times the rated voltage (IEC 60335-2-40) Heating elements energized at voltage which gives an electrical input of 1,15 times maximum rated power input (IEC 60335-2-40) TRF No. IEC60335_2_40F P 240 V x 1,06 = 254,4 V P N/A Page 12 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause 11.5 Requirement + Test Result Test conducted in heating mode and cooling mode, if both exist (IEC 60335-2-40) Verdict P All supplementary heating elements operative simultaneously (IEC 60335-2-40) N/A 11.6 Defrost test in most unfavourable conditions, if needed (IEC 60335-2-40) N/A 11.7 Appliances operated continuously until steady conditions except for defrost tests (IEC 60335-2-40) 11.8 Temperatures not exceeding values of table 3 (IEC 60335-2-40/A2) 11.9 P (See appended tables) P Protective devices do not operate (IEC 60335-2-40) P Sealing compound not flowing out (IEC 60335-2-40) P Temperature of air in outlet duct not exceed 90 °C (IEC 60335-2-40) N/A Test casing and installation of appliances in accordance with manufacturer’s instructions (IEC 60335-2-40) N/A Glass fibre insulation for appliances without indication of minimum clearances according to manufacturer; thermocouple in contact with enclosure (IEC 60335-2-40) N/A 13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE — 13.1 Leakage current not excessive and electric strength adequate P Heating appliances operated at 1,15 times rated power input .......................................................................... : Motor-operated appliances and combined appliances supplied at 1,06 times rated voltage........................ : 13.2 240 V x 1,06 = 254,4 V P Protective impedance and radio interference filters disconnected before carrying out the tests N/A Leakage current measured by means of the circuit described in figure 4 of IEC 60990 P Leakage current measurements (IEC 60335-2-40) 13.3 N/A (See appended table) P Appliance disconnected from supply and insulation is immediately subjected to voltage having frequency of 50 Hz or 60 Hz for 1 min, in accordance with IEC 61180-1 (IEC 60335-1/A1) P High-voltage source used for test is to be capable of supplying short circuit current Is between the output terminals after output voltage adjusted to appropriate test voltage (IEC 60335-1/A1) P TRF No. IEC60335_2_40F Page 13 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause Requirement + Test Result P Overload release of circuit is not to be operated by any current below tripping current Ir. Values of Is and Ir given in table 5 for various high-voltage sources (IEC 60335-1/A1) No breakdown during the tests Verdict (See appended table) P 19 ABNORMAL OPERATION — 19.1 The risk of fire or mechanical damage under abnormal or careless operation obviated (tests 19.2-19.14) (IEC 60335-2-40) P Failure of transfer medium flow or of any control device not result in a hazard (IEC 60335-2-40) P Electronic circuits so designed and applied that a fault will not render the appliance unsafe (electric shock, fire or mechanical hazard, dangerous malfunction) (test 19.11 and 19.12) (IEC 60335-2-40) P Test of appliance with motor rotors, other than motor-compressors, operated for 15 days (360 h) or until protection device opens circuit (IEC 60335-2-40) P 19.2 Insulation of motor windings (IEC 60335-2-40) .......: (See appended table) P Temperature of enclosure does not exceed (C) (IEC 60335-2-40)......................................................: (See appended table) P Temperature of the windings does not exceed the values shown in the table ; temperature (C) (IEC 60335-2-40)......................................................: (See appended table) P Electric strength test as specified in 16.3, 72 h after the beginning of the test (IEC 60335-2-40) P 30 mA residual current device does not open (IEC 60335-2-40) P At the end, leakage current between windings and enclosure does not exceed 2 mA (IEC 60335-2-40) P 24 COMPONENTS — 24.1 Components comply with safety requirements in relevant IEC standards P List of components (See appended table) P Components not tested and found to comply with relevant IEC standard for number of cycles specified, tested in accordance with clause 24.1.1 to 24.1.9 (IEC 60335-1/A2) N/A Components not tested and found to comply with relevant IEC standard, components not marked or not used in accordance with its marking, tested under the conditions occurring in the appliance P TRF No. IEC60335_2_40F Page 14 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause 24.1.1 24.1.2 24.1.3 24.1.4 Requirement + Test Result Verdict Lampholders and starterholders not being tested and found to comply with relevant IEC standard, tested as a part of appliance and additionally according to gauging and interchangeability requirements of relevant IEC standard (IEC 60335-1/A2) N/A Motor-compressors not tested according to IEC 60335-2-34 (not necessary to meet all requirements of IEC 60335-2-34) (IEC 60335-2-40) N/A Capacitors likely to be permanently subjected to the supply voltage and used for radio interference suppression or for voltage dividing, complying with IEC 60384-14, or P tested according to annex F N/A Safety isolating transformers complying with IEC 61558-2-6, or N/A tested according to annex G N/A Switches complying with IEC 61058-1, the number of cycles of operation being at least 10 000, or N/A tested according to annex H N/A If the switch operates a relay or contactor, the complete switching system is subjected to the test N/A Automatic controls complying with IEC 60730-1 with relevant part 2. The number of cycles of operation being: — - thermostats: ................................................. 10 000 N/A - temperature limiters: ...................................... 1000 N/A - self-resetting thermal cut-outs (IEC 60335-2-40):3000 N/A - voltage maintained non-self-resetting thermal cut-outs: .......................................................... 1000 N/A - other non-self-resetting thermal cut-outs (IEC 60335-2-40): ............................................ 300 N/A - timers: ............................................................. 3000 N/A - energy regulators: ....................................... 10 000 N/A - thermostats which control motor-compressor (IEC 60335-2-40): ..................................... 100 000 N/A - motor-compressor starting relays (IEC 60335-2-40): ................................................................... 100 000 N/A - automatic thermal motor-protectors for hermetic and semi-hermetic type motor-compressors (not less than number of operations during locked rotor test) (IEC 60335-2-40): ................................... min 2000 N/A - manual reset thermal motor-protectors for hermetic and semi-hermetic type motor-compressors (IEC 60335-2-40): .............................................. 50 N/A TRF No. IEC60335_2_40F Page 15 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause Requirement + Test - other automatic thermal motor-protectors (IEC 60335-2-40): .......................................... 2000 Result Protector for fan motors Verdict P - other manual reset thermal motor-protectors (IEC 60335-2-40): .............................................. 30 N/A Thermal motor protectors are tested in combination with their motor under the conditions specified in annex D (IEC 60335-1/A1) N/A For water valves containing live parts and that are incorporated in external hoses for connection of an appliance to the water mains, the degree of protection declared for subclause 6.5.2 of IEC 60730-2-8 is IPX7 (IEC 60335-1/A1) N/A Appliance couplers complying with IEC 60320-1 N/A However, appliances classified higher than IPX0, the appliance couplers complying with IEC 60320-2-3 (IEC 60335-1/A1) N/A Interconnection couplers complying with IEC 60320-2-2 N/A 24.1.6 Small lamp holders similar to E10 lampholders complying with IEC 60238, the requirements for E10 lampholders being applicable N/A 24.1.7 Remote operation of appliance via telecommunication network, relevant standard for telecommunication interface circuitry in appliance is IEC 62151 (IEC 60335-1/A2) N/A 24.1.8 Standard for thermal links IEC 60691 (IEC 60335-1/A2) N/A Thermal links not complying with IEC 60691 considered to be an intentionally weak part for purposes of clause 19 (IEC 60335-1/A2) N/A 24.1.5 24.1.9 24.2 Relays, other than motor starting relays, tested as part of appliance (IEC 60335-1/A2) P They also tested in accordance with clause 17 of IEC 60730-1, number of operations in clause 24.1.4 selected according to relay function in the appliance (IEC 60335-1/A2) .....................................................: P No switches or automatic controls in flexible cords P No devices causing the protective device in the fixed wiring to operate in the event of a fault in the appliance P No thermal cut-outs that can be reset by soldering P 24.3 Switches intended for all-pole disconnection of stationary appliances are directly connected to the supply terminals and having a contact separation in all poles, providing full disconnection under overvoltage category III conditions N/A 24.4 Plugs and socket-outlets for extra-low voltage circuits and heating elements, not interchangeable with plugs and socket-outlets listed in IEC 60083 or IEC 60906-1 or with connectors and appliance inlets complying with the standard sheets of IEC 60320-1 N/A TRF No. IEC60335_2_40F Page 16 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause 24.5 Requirement + Test Result Verdict Capacitors in auxiliary windings of motors marked with their rated voltage and capacitance and used accordingly P Voltage across capacitors in series with a motor winding does not exceed 1,1 times rated voltage, when the appliance is supplied at 1,1 times rated voltage under minimum load P Working voltage of motors connected to the supply mains and having basic insulation that is inadequate for the rated voltage of the appliance, not exceeding 42 V N/A In addition, the motors are complying with the requirements of annex I N/A 24.7 Hose-sets for connection of appliances to the water mains, complying with IEC 61770 and supplied with the appliance (IEC 60335-1/A1) N/A 24.101 Replaceable parts of thermal control devices identified by marking (IEC 60335-2-40) N/A 29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION — Clearances, creepage distances and solid insulation withstand electrical stress P 24.6 Coatings used on printed circuits boards to protect microenvironment (Type 1 coating) or (IEC 60335-1/A2) N/A to provide basic insulation (Type 2 coating), annex J applies (IEC 60335-1/A2) N/A Microenvironment is pollution degree 1 under Type 1 coating (IEC 60335-1/A2) N/A No clearance or creepage distance requirements under Type 2 coating (IEC 60335-1/A2) N/A For motor-compressor complies with IEC 60335-2-34, parts related not checked (IEC 60335-2-40) For motor-compressor not complying with IEC 60335-2-34, additions and modifications as specified (IEC 60335-2-40) 29.1 Clearances not less than the values specified in table 16, taking into account the rated impulse voltage for overvoltage categories of table 15, unless (IEC 60335-1/A1) for basic insulation and functional insulation, they comply with the impulse voltage test of clause 14 (IEC 60335-1/A1) However, if construction is affected by wear, distortion, movement of the parts or during assembly, the clearances for rated impulse voltages of 1 500 V and above are increased by 0,5 mm and the impulse voltage test is not applicable (IEC 60335-1/A1) TRF No. IEC60335_2_40F P N/A P N/A P Page 17 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause Requirement + Test Result Impulse voltage test not applicable (IEC 60335-1/A1): — - when the microenvironment is pollution degree 3 (IEC 60335-1/A1) P - for basic insulation of class 0 and class 0I appliances (IEC 60335-1/A1) N/A Appliances are in overvoltage category II Compliance is checked by inspection and measurements as specified 29.1.1 Verdict Clearances of basic insulation withstand the overvoltage, taking into account the rated impulse voltage Clearance at the terminals of tubular sheathed heating elements may be reduced to 1 mm if the microenvironment is pollution degree 1 P (See appended table) P P N/A Lacquered conductors of windings considered to be bare conductors (IEC 60335-1/A1) P 29.1.2 Clearances of supplementary insulation not less than those specified for basic insulation in table 16 P 29.1.3 Clearances of reinforced insulation not less than those specified for basic insulation in table 16, but using the next higher step for rated impulse voltage P 29.1.4 For functional insulation, the values of table 16 are applicable, unless P the appliance complies with clause 19 with the functional insulation short-circuited 29.1.5 N/A Lacquered conductors of windings considered to be bare conductors (IEC 60335-1/A1) P However, clearances at crossover points are not measured P Clearance between surfaces of PTC heating elements may be reduced to 1 mm N/A Lacquered conductors of windings assumed to be bare conductors, but the clearances specified in table 16 are reduced by 0,5 mm for rated impulse voltages of at least 1500 V P Appliances having higher working voltage than rated voltage, the voltage used for determining clearances from table 16 is the sum of the rated impulse voltage and the difference between the peak value of the working voltage and the peak value of the rated voltage P If the secondary winding of a step-down transformer is earthed, or if there is an earthed screen between the primary and secondary windings, clearances of basic insulation on the secondary side not less than those specified in table 16, but using the next lower step for rated impulse voltage N/A TRF No. IEC60335_2_40F Page 18 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause Requirement + Test Result Circuits supplied with a voltage lower than rated voltage, clearances of functional insulation based on the working voltage used as the rated voltage in table 15 29.2 N/A Creepage distances not less than those appropriate for the working voltage, taking into account the material group and the pollution degree Pollution degree 2 applies, unless P For PCB of indoor unit only precautions taken to protect the insulation; pollution degree 1 insulation subjected to conductive pollution; pollution degree 3 P N/A For parts except PCB of indoor unit P Compliance is checked by inspection and measurements as specified P Insulation located in airflow, pollution degree 3 unless (IEC 60335-2-40) P insulation enclosed or located so that unlikely to be exposed to pollution due to normal use (IEC 60335-2-40) 29.2.1 Verdict Creepage distances of basic insulation not less than specified in table 17 For pollution degree 1, creepage distance not less than the minimum specified for the clearance in table 16, if the clearance has been checked according to the test of clause 14 For PCB of indoor unit only P P N/A 29.2.2 Creepage distances of supplementary insulation at least as specified for basic insulation in table 17 P 29.2.3 Creepage distances of reinforced insulation at least double as specified for basic insulation in table 17 P 29.2.4 Creepage distances of functional insulation not less than specified in table 18 P Creepage distances may be reduced if the appliance complies with clause 19 with the functional insulation short-circuited N/A 30 RESISTANCE TO HEAT AND FIRE — 30.1 External parts of non-metallic material, P parts supporting live parts, and P thermoplastic material providing supplementary or reinforced insulation, P sufficiently resistant to heat P Ball-pressure test according to IEC 60695-10-2 P External parts: at 40 °C plus the maximum temperature rise determined during the test of clause 11, or at 75 °C, whichever is the higher; temperature (°C)....: P TRF No. IEC60335_2_40F Page 19 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause 30.2 Requirement + Test P Parts of thermoplastic material providing supplementary or reinforced insulation, 25 °C plus the maximum temperature rise determined during clause 19, if higher; temperature (°C) ......................: N/A Parts of non-metallic material adequately resistant to ignition and spread of fire P Requirement does not apply to decorative trims, knobs and other parts unlikely to be ignited or to propagate flames that originate inside the appliance P Compliance checked by test of clause 30.2.1. In addition: — - unattended appliances, clause 30.2.3 applies Appliances for remote operation, clause 30.2.3 applies (IEC 60335-1/A2) 30.2.3 N/A P N/A Base material of printed circuit board, clause 30.2.4 applies P Glow-wire test of IEC 60695-2-11 at 550 C, unless P material is classified at least HB40 according to IEC 60695-11-10 (IEC 60335-1/A2) N/A Parts for which the glow-wire test cannot be carried out meet the requirements in ISO 9772 for category HBF material (IEC 60335-1/A1) N/A Appliances operated while unattended, tested as specified in 30.2.3.1 and 30.2.3.2 Test not applicable to conditions as specified 30.2.3.1 Verdict Parts supporting live parts: at 40 °C plus the maximum temperature rise determined during the test of clause 11, or at 125 °C, whichever is the higher; temperature (°C).......................................................: - attended appliances, clause 30.2.2 30.2.1 Result P N/A Parts of non-metallic material supporting connections carrying a current exceeding 0,2 A during normal operation, and (IEC 60335-1/A2) P parts of non-metallic material within a distance of 3 mm, (IEC 60335-1/A2) P subjected to glow-wire test of IEC 60695-2-11 with a test severity of 850 °C (IEC 60335-1/A2) P However, glow-wire test not carried out on parts of material classified as having a glow-wire flammability index of at least 850 C according to IEC 60695-2-12 (IEC 60335-1/A2) N/A Glow-wire flammability index only used if in specified range of thickness (IEC 60335-1/A2) N/A Glow-wire test not carried out on small parts comply with needle-flame test of annex E or on small parts of material classified as V-0 or (IEC 60335-1/A2) N/A V-1 according to IEC 60695-1-10 (IEC 60335-1/A2) N/A TRF No. IEC60335_2_40F Page 20 of 41 Report No. GZES120900879606 IEC 60335-2-40 Clause 30.2.3.2 Requirement + Test Result Classified V-0 or V-1 material only used if in specified range of thickness (IEC 60335-1/A2) N/A Test as specified for an interposed shielding material (IEC 60335-1/A2) N/A Parts of non-metallic material supporting current-carrying connections, and (IEC 60335-1/A2) P parts of non-metallic material within a distance of 3 mm, (IEC 60335-1/A2) P subjected to glow-wire test of IEC 60695-2-11 P However, glow-wire test not carried out on material having a glow-wire ignition temperature according to IEC 60695-2-13 of at least: Glow-wire test of IEC 60695-2-11, the temperature being: N/A — - 775 °C, for connections carrying a current exceeding 0,2 A during normal operation N/A - 675 °C, for other connections N/A Glow-wire ignition temperature only used if in specified range of thickness (IEC 60335-1/A2) N/A Test as specified for an interposed shielding material (IEC 60335-1/A2) N/A When glow-wire test of IEC 60695-2-11 carried out, temperatures are: 30.2.4 Verdict — - 750 °C, for connections carrying a current exceeding 0,2 A during normal operation N/A - 650 °C, for other connections N/A If a flame persists longer than 2 s during test, then these parts and adjacent parts further subjected to needle-flame test of annex E, unless (IEC 60335-1/A1 corr.1) N/A material is classified as V-0 or V-1 according to IEC 60695-11-10 (IEC 60335-1/A2) N/A Classified V-0 or V-1 material only used if in specified range of thickness (IEC 60335-1/A2) N/A Base material of printed circuit boards subjected to needle-flame test of annex E (IEC 60335-1/A2) P Test not carried out by specified items ....................: N/A TRF No. IEC60335_2_40F Page 21 of 41 Report No. GZES120900879606 IEC 60335-2-40 10.1 P TABLE: Power input deviation P rated (W) P measured (W) P Required P 230 V, 50 Hz 1300 1078,9 -17,0% +15% GWH09MB-K3DNC1K (Cooling mode) 230 V, 50 Hz 1400 519,8 -62,9% +15% GWH09MB-K3DNC1K (Heating mode) 230 V, 50 Hz 1400 1247,9 -10,9% +15% GWH12MB-K3DNC1K (Cooling mode) 230 V, 50 Hz 1550 522,8 -66,3% +15% GWH12MB-K3DNC1K (Heating mode) Input deviation of/at: Remark Supplementary information: The data listed in the table were the maximum measured values for the test samples assembled with all alternative fan motors. 11.8 TABLE: Heating test, thermocouples (GWH09MB-K3DNC1K) P Tested voltage ..........................................................: 240 V x 1,06 = 254,4 V — Ambient, t (°C) ..........................................................: Cooling mode: Indoor: DB: 32, WB: 23; Outdoor: DB: 43, WB: 26 — Heating mode: Indoor: DB: 27, WB: Outdoor: DB: 24, WB: 18 Thermocouple locations T (°C) Cooling Max. T (°C) Heating Indoor unit Power cord 39,0 33,4 75 Plastic enclosure 31,8 27,2 For clause 30.1 Terminal block 33,5 27,9 85 Swing motor Indoor fan motor enclosure 33,5 35,1 90 (Class A) 40,6 36,2 105 (Class E) Main PCB 34,2 30,2 145 High frequency transformer 43,9 41,2 105 (Class E) Fan motor running capacitor 37,9 33,4 T70 Relay for compressor 36.8 33.0 T50 Relay for fan motor 37,2 33,1 T85 Outdoor unit Interconnection cord 43,3 24,1 75 Terminal block 44,0 24,4 85 Lead wiring for compressor 57,4 34,1 75 Compressor housing 86,8 61,5 For reference Discharge pipe of compressor 89,0 62,2 For reference TRF No. IEC60335_2_40F Page 22 of 41 Report No. GZES120900879606 IEC 60335-2-40 Outdoor fan motor winding (FW30J-ZL NIDEC SHIBAURA) 71,2 23,3 105 (Class E) 4-way valve winding 58,7 73,0 110 (Class B) Reactor winding 51,9 30,4 165 (Class H) Main PCB 47,6 26,9 145 X capacitor 47,2 23,5 T100 Varistor 42,8 26,4 T85 High frequency transformer 53,7 31,8 105 (Class E) Relay on main board 51,4 27,3 T70 Test floor 47,3 20,8 90 Supplementary information: —— 11.8 TABLE: Heating test, thermocouples (GWH12MB-K3DNC1K) P Tested voltage ..........................................................: 240 V x 1,06 = 254,4 V — Ambient, t (°C) ..........................................................: Cooling mode: Indoor: DB: 32, WB: 23; Outdoor: DB: 43, WB: 26 — Heating mode: Indoor: DB: 27, WB: Outdoor: DB: 24, WB: 18 Thermocouple locations T (°C) Cooling Max. T (°C) Heating Indoor unit Power cord 32,2 28,2 75 Plastic enclosure 33,2 28,2 For clause 30.1 Terminal block 32,7 28,7 85 Swing motor Indoor fan motor enclosure 37,4 27,9 90 (Class A) 40,3 37,1 105 (Class E) Main PCB 32,3 28,6 145 High frequency transformer 43,6 41,2 105 (Class E) Fan motor running capacitor 36,1 29,6 T70 Outdoor unit Terminal block 37,2 22,7 85 Lead wiring for compressor 51,0 30,3 75 Compressor housing 87,5 63,2 For reference Discharge pipe of compressor Outdoor fan motor winding (FW30J-ZL Panasonic) Outdoor fan motor winding (FW30J-ZL Shinano) 86,6 61,8 For reference 55,0 23,5 105 (Class E) 56,9 25,3 105 (Class E) 4-way valve winding 51,3 73,4 110 (Class B) TRF No. IEC60335_2_40F Page 23 of 41 Report No. GZES120900879606 IEC 60335-2-40 Main PCB 50,4 27,5 145 High frequency transformer 59,0 32,9 105 (Class E) Relay on main board 50,9 28,3 T70 Test floor 48,8 22,4 90 Supplementary information: the recorded values are the max value of alternative fan motor 13.2 P TABLE: Leakage current Heating appliances: 1,15 x rated power input .......: Motor-operated and combined appliances: 1,06 x rated voltage................................................: 240 V x 1,06 = 254,4 V Leakage current between I (mA) Max. allowed I (mA) L/N and earthed metal enclosure 0,37 3,5 L/N and plastic enclosure of indoor unit 0,08 0,25 L/N and plastic handle of outdoor unit 0,08 0,25 L/N and earthed metal enclosure 0,38 3,5 L/N and plastic enclosure of indoor unit 0,09 0,25 L/N and plastic handle of outdoor unit 0,08 0,25 For model GWH09MB-K3DNC1K For model GWH12MB-K3DNC1K Supplementary information: The data listed in the table were the maximum measured values for the samples assembled with all alternative fan motors. 13.3 P TABLE: Electric strength Test voltage applied between: Voltage (V) Breakdown (Yes/No) Live parts and earthed metal enclosure 1000 No Live parts on display board and insulation cover of display board 1750 No L/N and surface of display panel 3000 No Supplementary information: The data listed in the table were the maximum measured values for the samples assembled with all alternative fan motors. TRF No. IEC60335_2_40F Page 24 of 41 Report No. GZES120900879606 IEC 60335-2-40 19.2 P TABLE: Abnormal operation Tested voltage 240 V t1 (C).........................................................................: 23,0 t2 (C).........................................................................: 23,0 Temperature T of part / at: T (C) Required T (C) Outdoor fan motor winding (FW30J-ZL Panasonic) 93,8 165 (class E) fan motor enclosure (FW30J-ZL Panasonic) 85,6 150 Outdoor fan motor winding (FW30J-ZL Shinano) 28,8 165 (class E) fan motor enclosure (FW30J-ZL Shinano) 27,5 150 Outdoor fan motor winding (FW30J-ZL NIDEC SHIBAURA) 98,6 165 (class E) fan motor enclosure (FW30J-ZL NIDEC SHIBAURA) 91,5 150 Remark: —— 24.1 P TABLE: Components Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of conformity Indoor unit Plug Guangdong Huasheng Electrical Appliances Co., Ltd. Plug (Alternative) AC 250 V, 16 A DIN VDE 0620-1: VDE 2010-02 40006002 Changzhou Hong Chang DTIII-2P-05 Electronics Co., Ltd. AC 250 V, 16 A DIN VDE 0620-1: VDE 2010-02 40015536 Power cord Guangdong Huasheng Electrical Appliances Co., Ltd. H05VV-F 3G 1,5 mm2 DIN VDE 0281-5: VDE 2002-09 40005362 Power cord (Alternative) Changzhou Hong Chang H05VV-F Electronics Co., Ltd. 3G 1,5 mm2 DIN VDE 0281-5: VDE 124978 2002-09 TRF No. IEC60335_2_40F CT-104 Page 25 of 41 Report No. GZES120900879606 IEC 60335-2-40 Power cord (Alternative for models GWH09MBK3DNA2K, GWH12MBK3DNA2K, GWH09MBK3DNA5K, GWH12MBK3DNA5K, GWH09MBK3DNB3K, GWH09MBK3DNE1K, GWH09MBK3DNC9K, GWH09MBK3DNA4K, GWH12MBK3DNB3K, GWH12MBK3DNE1K, GWH12MBK3DNC9K, GWH12MBK3DNA4K) Guangdong Huasheng Electrical Appliances Co., Ltd. H05VV-F 3G 1,0 mm2 DIN VDE 0281-5: VDE 2002-09 40005362 Power cord (Alternative for models GWH09MBK3DNE2K, GWH09MBK3DNE3K, GWH12MBK3DNE2K, GWH12MBK3DNE3K) Guangdong Huasheng Electrical Appliances Co., Ltd. H05VV-F 3G 1,0 mm2 DIN VDE 0281-5: VDE 2002-09 40005362 Power cord (Alternative for models GWH09MBK3DNB7K, GWH09MBK3DNC5K, GWH12MBK3DNB7K, GWH12MBK3DNC5K) Guangdong Huasheng Electrical Appliances Co., Ltd. H05VV-F 3G 1,0 mm2 DIN VDE 0281-5: VDE 2002-09 40005362 Terminal block Changzhou Changheng Kaidu Electric Appliances Co., Ltd. AC 250 V, 2,5 mm EN 60998-1: 2004; EN 60998-2-1: 2004; EN 60335-2-40; EN 60335-1 TRF No. IEC60335_2_40F JX-G-4C 2 Tested with appliance VDE 40020936 Page 26 of 41 Report No. GZES120900879606 IEC 60335-2-40 Terminal block (Alternative) Zhen jiang Honglian Electrician Co., Ltd. JX1239 AC 250 V, 2,5 mm2 EN 60335-2-40; EN 60335-1 Tested with appliance Tested with appliance VDE 40013197 Terminal block (Alternative) Nantong Huaguan Electric JXW-4-G1 Co., Ltd. AC 250 V, 2,5 mm EN 60998-1: 2004; EN 60998-2-1: 2004; EN 60335-2-40; EN 60335-1 Swing motor Changzhou LeiLi Electrical MP24AA Equipment Co., Ltd. 12 VDC, Class A EN 60335-2-40; EN 60335-1 Tested with appliance Swing motor (Alternative) Jiangsu Huayang Electrical MP24AA Appliance Co., Ltd. 12 VDC, Class A EN 60335-2-40; EN 60335-1 Tested with appliance Swing motor (Alternative) Changzhou Oukai Electrical Appliance Co., Ltd. MP24AA 12 VDC, Class A EN 60335-2-40; EN 60335-1 Tested with appliance Swing motor (Alternative) Hefei Rishang Electrical Co., Ltd. MP24AA 12 VDC, Class A EN 60335-2-40; EN 60335-1 Tested with appliance Swing motor (Alternative) Zhongshan Huilipu Motor Co., Ltd. MP24AA 12 VDC, Class A EN 60335-2-40; EN 60335-1 Tested with appliance Indoor fan motor Jiangsu Shangqi Group Co., Ltd. FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance Indoor fan motor (Alternative) Zhongshan Broad-Ocean Motor Co., Ltd. FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance FN20J-PG 220-240 V, 50 Hz, 20 W, Class E EN 60335-2-40; EN 60335-1 Tested with appliance BR Series AC 250 V, 5 A, Operation: 100 ℃ EN 60730-1; EN 60730-2-2 VDE 132813 Indoor fan motor (Alternative) Indoor fan motor (Alternative) Indoor fan motor (Alternative) Indoor fan motor (Alternative) Motor protector Zhuhai Kaibang Motor Manufacture Co., Ltd. Changzhou Regal-Beloit Sinya Motor Co., Ltd. Zhejiang Wolong Home Appliance Motor Co., Ltd. Zhuhai City Tongde Electric Equipment Co., Ltd. Jiangsu Changsheng Electric Appliance Co., Ltd. TRF No. IEC60335_2_40F 2 Page 27 of 41 Report No. GZES120900879606 IEC 60335-2-40 Motor protector (Alternative) Changzhou Changhong Tongli Electric Appliance Co., Ltd. KW Series AC 250 V, 8 A, Operation: 100℃ EN 60730-1; EN 60730-2-2 VDE 40020906 Motor protector (Alternative) Sensata Technologies Holland B.V. BRL Series AC 250 V, 8 A; Operation: 100℃ EN 60730-1; EN 60730-2-2 KEMA 2089558.01 Main board for models other than GWH12MBK3DND8D, GWH09MBK3DND8D Gree Electric Appliances, Inc. of Zhuhai M839F2PJ — EN 60335-2-40; EN 60335-1 Tested with appliance - Indoor fan motor running capacitor Wuxi Xixi Capacitor Co., Ltd. CBB61 AC 500 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50128479 - Indoor fan motor running capacitor (Alternative) Zhuhai Gree Xinyuan Electronic Co., Ltd. CBB61 AC 500 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50120798 - Indoor fan motor running capacitor (Alternative) Xiamen Faratronic Co., Ltd. CBB61 AC 500 V, 1,0 uF, T70 EN 60252-1: 2001 VDE 40004094 - Indoor fan motor running capacitor (Alternative) Ningbo Shine Electronical Co., Ltd. CBB61A AC 500 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50065558 - Indoor fan motor running capacitor (Alternative) AnHui FeiDa Industry Stock Co., Ltd. CBB61 AC 450 V, 1 uF, T85 EN 60252-1: 2001 VDE 40012579 - Indoor fan motor running capacitor (Alternative) Shanghai Haoye Capacitors Co., MKNS105 Ltd. AC 450 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50035566 - Indoor fan motor running capacitor (Alternative) Foshan Shunde Fongming Electronic Tech. Co., Ltd. CBB61 AC 450 V, 1,0 uF, T70 EN 60252-1: 2001 VDE 40006835 Main board for models GWH12MBK3DND8D, GWH09MBK3DND8D Gree Electric Appliances, Inc. of Zhuhai M839F2GJ — EN 60335-2-40; EN 60335-1 Tested with appliance TRF No. IEC60335_2_40F Page 28 of 41 Report No. GZES120900879606 IEC 60335-2-40 - Indoor fan motor running capacitor Ningbo Shine Electrical Co., Ltd. - Indoor fan motor running capacitor (Alternative) AC 450 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50076953 Shanghai Haoye Capacitors Co., MKPS105 Ltd. AC 450 V, 1,0 uF, T70 EN 60252-1: 2001 TUV R50035566 X2 capacitor 1# Xiamen Faratronic Co., Ltd. MKP62 AC 275 V, 104M, T110 EN 132400 EN 60384-14 VDE 40000358 X2 capacitor 1# (Alternative) OKAYA Electric Industries Co., Ltd. LE104 AC 275 V, 0,1 uF, T100 EN 132400 EN 60384-14 SEMKO SE/0142-1 MKP AC 275 V, 0,1 uF, T100 EN 60384-14: 2005-08 VDE 40024537 MKP62 AC 275 V, 105K, T110 EN 132400; EN 60384-14 VDE 40000358 X2 capacitor 1# (Alternative) X2 Capacitor 2# Anhui Xinyang electronics Co., Ltd. Xiamen Faratronic Co., Ltd. CBB61S X2 Capacitor 2# (Alternative) Pilkor Electronics PCX2 335M Co., Ltd. AC 275 V, 1,0 uF, T85 EN 132400; EN 60384-14 SEMKO SE/0256-2 X2 Capacitor 2# (Alternative) Anhui Xinyang Electronics Co., Ltd. AC 275 V, 1,0 uF, T100 EN 60384-14: 2005-08 VDE 40024537 MKP IEC 61051-1 IEC 61051-2 IEC 61051-2-2 CECC 42000/A1 CECC 42200/A1 CECC 42201/A1 IEC 61051-1 IEC 61051-2 IEC 61051-2-2 CECC 42000 CECC 42200 CECC 42201 Varistor Chengdu Tieda Electroni Co., Ltd. MYN15-621K AC 385 V, T85 Varistor (Alternative) Xianhua Advanced Technology Holding) Co., Ltd. FNR-14K621 AC 380 V, T85 Optocoupler 1# Toshiba Corporation TLP781 Vceo: 80 V; If: 60 mA; Ic: 50 mA DIN EN 60747-5- VDE 2: 2003 40021173 Optocoupler 2# Sharp Corporation PC817 Vceo: 80 V; If: 50 mA; Ic: 50 mA DIN EN 60747-5- VDE 2: 2003 40008087 High frequency transformer Xinji Electronics Component EE25-9PA (HangZhou) Co., Ltd. High-frequency transformer (Alternative) Huizhou Jiayang Electronic New- EE25-9PA tech Co., Ltd. TRF No. IEC60335_2_40F Input: 80 V-260 V, 65KHz, 1,26Ω; Output: 18 V, 100 mA; 12 V 500 mA; 5 V, 500 mA; Class E Input: 85 V-265 V, 65 KHz, 1,26Ω; Output: 18 V, 100 mA; 12 V, 500 mA; 5 V, 500 mA; Class B VDE 40008571 VDE 40008242 EN 60335-2-40; EN 60335-1 Tested with appliance EN 60335-2-40; EN 60335-1 Tested with appliance Page 29 of 41 Report No. GZES120900879606 IEC 60335-2-40 High-frequency transformer (Alternative) Dongguan Dazhong Electronic Co., Ltd. EE25-9PA High-frequency transformer (Alternative) Shenzhen Jingquanhua Electronic Co., Ltd. EE25-9PA Hangzhou Ruichuang Inductance Industry And Trade Co., Ltd. Xinji Electronics Inductance Component (Alternative) (Hangzhou) Co., Ltd. Shenzhen Inductance Yamaxi (Alternative) Electronic Co., Ltd. Huizhou Jiayang Inductance Electronic New(Alternative) tech Co., Ltd. Fenghua Advanced Inductance Technology (Alternative) (Holding) Co., Ltd. Dongguan Inductance Dazhong (Alternative) Electronic Co., Ltd. Xinji Electronics Component Filter (Hangzhou) Co., Ltd. Shenzhen Yamaxi Filter (Alternative) Electronic Co., Ltd. Dongguan Dazhong Filter (Alternative) Electronic Co., Ltd. Input: 85 V-265 V, 65 KHz, 1,26Ω; Output: 18 V, 100 mA; 12 V, 500 mA; 5 V, 500 mA; Class B Input: 85 V-265 V, 65 KHz, 1,26Ω; Output: 18 V, 100 mA; 12 V, 500 mA; 5 V, 500 mA; Class E EN 60335-2-40; EN 60335-1 Tested with appliance EN 60335-2-40; EN 60335-1 Tested with appliance 200uH/2A 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance 200uH/2A 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance T50-26 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance 200uH/2A 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance 200uH/2A 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance 200uH/2A 200 uH, 2 A EN 60335-2-40; EN 60335-1 Tested with appliance SF2022A05220 AC 250 V, 0,5 A EN 60335-2-40; EN 60335-1 Tested with appliance SF2022A05220 AC 250 V, 0,5 A EN 60335-2-40; EN 60335-1 Tested with appliance SF2022A052 AC 250 V, 0,5 A 20 EN 60335-2-40; EN 60335-1 Tested with appliance EN 61810-1: 2004; IEC 61810-1: 2004 VDE 40024142 Relay for compressor Xiamen Hongfa Electroacoustic Co., Ltd. JQX-102F 250 V~; 20 A; T85; DC 12 V; cycles: 10E4 Relay for compressor (Alternative) Omron Electronic Components (Shenzhen) Ltd. G4A-1A-ECN 250 V~; 20 A; T85; DC 12 V; cycles: 10E4 EN 61810-1: 2008 TUV R50214482 Relay for compressor (Alternative) Omron Corporation G4A-1A-ECN 250 V~; 20 A; T50; DC 12 V; cycles: 10E4 EN 61810-1 EN 60255-23 VDE 107293 TRF No. IEC60335_2_40F Page 30 of 41 Report No. GZES120900879606 IEC 60335-2-40 Relay for compressor (Alternative) Dongguan Sanyou Electrical Appliances Co., Ltd. Songchuan Precision Co., Ltd. Relay for compressor (Alternative) Tyco Electronics (Shenzhen) Co. Ltd. EF00-1A2D012-F Relay for indoor fan motor Xiamen Hongfa Electroacoustic Co., Ltd. JZC-43F Relay for indoor fan motor (Alternative) Omron Corporation G5NB-1A Relay for compressor (Alternative) SFK-112DM 250 V~; 20 A; T85; DC 12 V; cycles: 10E4 EN 61810-1: 2004 IEC 61810-1: 2004 VDE 40007481 891WP-1A-C 250 V~; 25 A; T85; DC 12 V; cycles: 10E4 EN 61810-1: 2004 TÜV R3-50003966 250 V~;20 A; T85; DC 12 V; cycles: 10E4 EN 61810-1: 2004; IEC 61810-1: 2003 TUV R50117320 EN 61810-1 EN 60255-23 VDE 40002220 EN 61810-1 EN 60255-23 VDE 137575 277 VAC, 5 A, 12 VDC, cycles: 10E4, T85 EN 61810-1: 2004 TUV R50138320 250 VAC, 5 A, 12 VDC, cycles: 3E4, T85 EN 61810-1 EN 60255-23 VDE 40008369 EN 61810-1 EN 60255-23 VDE 40009151 250 VAC, 3 A, 12 VDC, cycles: 10E4, T85 250 VAC, 3 A, 12 VDC, cycles: 10E4, T85 Relay for indoor fan motor (Alternative) Dongguan Sanyou Electrical SRB-SAppliances Co., 112DM Ltd. Songchuan Precision Co., 202N-1AC-C Ltd. Relay for indoor fan motor (Alternative) Tyco Electronics (Shenzhen) Co., Ltd. 250 VAC, 3 A, 12 PCJ-112D3M VDC, cycles: 10E4, T90 Optical isolator Panasonic Electric Works Co., Ltd. AQH2223 Fuse link Hollyland 50T Company Limited AC 250 V, T 3,15 AL EN 60127-1: 1991+A1+A2; EN 60127-2: 2003+A1 VDE 40014460 Fuse link (Alternative) Suzhou Walter Electronic Co., Ltd. TSD AC 250 V, T 3,15 AL EN 60127-1: 1991+A1+A2; EN 60127-2: 2003+A1 VDE 40016851 NC 80 AC 600 V, 1,5 A EN 60335-2-40; EN 60335-1 Tested with appliance CCP-508U CEM-1, 94V-0 EN 60335-2-40 EN 60335-1 S3116 CEM-1, 94V-0 EN 60335-2-40 EN 60335-1 S1141 FR-4, 94V-0 EN 60335-2-40; EN 60335-1 S3110 CEM-1, 94V-0 EN 60335-2-40 EN 60335-1 KB3151C FR-1, 94V-0 EN 60335-2-40 EN 60335-1 Relay for indoor fan motor (Alternative) Rectifier PCB 1# PCB 1# (Alternative) PCB 1# (Alternative) PCB 1# (Alternative) PCB 1# (Alternative) Shindengen Electric MFG Co., Ltd. CHANG CHUN PLASTICS CO LTD SHENGYI TECHNOLOGY CO LTD SHENGYI TECHNOLOGY CO LTD SHENGYI TECHNOLOGY CO LTD KINGBOARD LAMINATES LTD TRF No. IEC60335_2_40F 250 VAC, 0,9A, T85 EN 60950: 2000 VDE 40004928 Tested with appliance UL E108591 Tested with appliance UL E109769 Tested with appliance UL E109769 Tested with appliance UL E109769 Tested with appliance UL E123995 Page 31 of 41 Report No. GZES120900879606 IEC 60335-2-40 PCB 2# PCB 2# (Alternative) PCB 2# (Alternative) PCB 2# (Alternative) Cold plasma generator SHENGYI TECHNOLOGY CO LTD KINGBOARD LAMINATES LTD SHENGYI TECHNOLOGY CO LTD NAN YA PLASTICS CORP CCL DEPT ELECTRONIC MATERIAL DIV Shandong Xuesheng Technology Co., Ltd. Tested with appliance UL E109769 Tested with appliance UL E123995 Tested with appliance UL E109769 S2130 CEM-3, 94V-0 EN 60335-2-40; EN 60335-1 KB6160 FR-4, 94V-0 EN 60335-2-40; EN 60335-1 S1141 FR-4, 94V-0 EN 60335-2-40; EN 60335-1 FR-4-86 FR-4, 94V-0 EN 60335-2-40; EN 60335-1 Tested with appliance UL E98983(S) XS-PL-06 AC 220-240 V, 50/60 Hz, ≤ 2 W EN 60335-1 EN 60335-2-65 TUV R50172899 Outdoor unit Interconnection cord Guangdong Huasheng Electrical Appliances Co., Ltd. H07RN-F 4G 1,5 mm2 DIN VDE 0282-4: VDE 2005-02 40016788 Interconnection cord (Alternative for models GWH09MBK3DNA2K, GWH12MBK3DNA2K, GWH09MBK3DNA5K, GWH12MBK3DNA5K, GWH09MBK3DNB3K, GWH09MBK3DNE1K, GWH09MBK3DNC9K, GWH09MBK3DNA4K, GWH12MBK3DNB3K, GWH12MBK3DNE1K, GWH12MBK3DNC9K, GWH12MBK3DNA4K) Guangdong Huasheng Electrical Appliances Co., Ltd. H07RN-F 4G 1,0 mm2 DIN VDE 0282-4: VDE 2005-02 40016788 TRF No. IEC60335_2_40F Page 32 of 41 Report No. GZES120900879606 IEC 60335-2-40 Interconnection cord (Alternative for models GWH09MBK3DNE2K, GWH09MBK3DNE3K, GWH12MBK3DNE2K, GWH12MBK3DNE3K) Interconnection cord (Alternative for models GWH09MBK3DNB7K, GWH09MBK3DNC5K, GWH12MBK3DNB7K, GWH12MBK3DNC5K) Guangdong Huasheng Electrical Appliances Co., Ltd. H07RN-F 4G 1,0 mm2 DIN VDE 0282-4: VDE 2005-02 40016788 Guangdong Huasheng Electrical Appliances Co., Ltd. H07RN-F 4G 1,0 mm2 DIN VDE 0282-4: VDE 2005-02 40016788 DC 260-350 V, 15120 Hz, 3Phase, Class B, R410A EN 60335-2-34: 2002+A11+A1+A 2; TUV EN 60335-1: R50135262 2002+A1+A11+A 12+A2+A13+A14 Compressor Zhuhai Landa QXACompressor Co., A091zE190A Ltd. Compressor protector Sensata Technoloies (Baoying) Co., Ltd. Compressor protector (Alternative) Compressor protector (Alternative) Outdoor fan motor AC 250 V, 100000 cycles; 1NT11L-6233 Open: (115±3)℃, Close: (95±5)℃ Changzhou Changrong Electrical HPC Appliance Co., Ltd. Jiangsu Changheng (Group) Control KSD Devices & Products Co., Ltd. Zhuhai Kaibang Motor FW30J-ZL Manufacture Co., Ltd. EN60730-2-9 EN60730-1 KEMA NO. 2014531.16 AC 250 V, 5 A; 10000 cycles; Operation: 115℃; Reset: 95℃ EN 60730-2-9 EN 60730-1 VDE 40032296 AC 250 V, 10 A; 35000 cycles; Operation: 115℃; Reset: 95℃ EN 60730-2-9 EN 60730-1 VDE 40022995 DC 176-375 V, 30 W, Class E EN 60335-2-40 EN 60335-1 Tested with appliance Outdoor fan motor (Alternative) Dongguan Shinano Motor Co., Ltd. FW30J-ZL DC 310 V, 30 W, Class E EN 60335-2-40 EN 60335-1 Tested with appliance Outdoor fan motor (Alternative) NIDEC SHIBAURA (Zhejiang) CORP FW30J-ZL 310V,0,36A, 30W, Class E, 76Ω EN 60335-2-40 EN 60335-1 Tested with appliance TRF No. IEC60335_2_40F Page 33 of 41 Report No. GZES120900879606 IEC 60335-2-40 Outdoor fan motor (Alternative) Panasonic Appliances Motor FW30J-ZL (Hangzhou) Co., Ltd. 310V, 30W, Class E, 76Ω EN 60335-2-40 EN 60335-1 Tested with appliance Outdoor fan motor (Alternative) Hefei Shinano Motor Co., LTD. FW30J-ZL 310V, 30W, 0,13A, Class E, 76Ω EN 60335-2-40 EN 60335-1 Tested with appliance 4-way valve Zhejiang Duan Precision Industries Group Co., Ltd. AC 220-240 V; DSF-4-R410A 50/60 Hz; 7/5 W; Class B EN 60730-1 VDE 40013212 4-way valve (Alternative) Zhejiang Sanhua AC 220-240 V, Climate and SHF-4H-23U50/60 Hz, 4,5/3,5 W, EN 60730-1 Appliance P Class B Controls Group Co., Ltd. VDE 40003240 Main board for models GWH09MBK3DNA3K, GWH09MBK3DND3K, GWH09MBK3DNA2K, GWH09MBK3DNA5K, GWH09MBK3DNB3K, GWH09MBK3DNE1K, GWH09MBK3DNC9K, GWH09MBK3DNA4K, GWH09MBK3DNE2K, GWH09MBK3DNE3K, GWH09MBK3DND8D, GWH09MBK3DNB7K, GWH09MBK3DNC5K, GWH09MBK3DNC1K, GWH09MBK3DNC8K Gree Electric Appliances, Inc. of Zhuhai Tested with appliance TRF No. IEC60335_2_40F W8283BX — EN 60335-2-40 EN 60335-1 Page 34 of 41 Report No. GZES120900879606 IEC 60335-2-40 Main board for models GWH12MBK3DNA3K, GWH12MBK3DND3K, GWH12MBK3DNA2K, GWH12MBK3DNA5K, GWH12MBK3DNB3K, GWH12MBK3DNE1K, GWH12MBK3DNC9K, GWH12MBK3DNA4K, GWH12MBK3DNE2K, GWH12MBK3DNE3K, GWH12MBK3DND8D, GWH12MBK3DNB7K, GWH12MBK3DNC5K, GWH12MBK3DNC1K, GWH12MBK3DNC8K Gree Electric Appliances, Inc. of Zhuhai Y1 Capacitor — EN 60335-2-40 EN 60335-1 Tested with appliance TDK-EPC Corporation, CD472M Capacitors Group AC 250 V, 472M, T70 EN 60384-14: 2005-08 VDE 40029780 Y1 Capacitor Murata Mfg. Co., Ltd. KX472M (Headquarters) 250VAC, 472M EN 60384-14: 2005-08 VDE 40002831 Y2 Capacitor TDK-EPC Corporation, CS472M Capacitors Group AC 250 V, 472M, T70 EN 60384-14: 2005-08 VDE 40029781 MKP62 AC 275 V, 104M, T110 EN 132400 EN 60384-14 VDE 40000358 LE104 AC 275 V, 0,1 uF, T100 EN 132400 EN 60384-14 SEMKO SE/0142-1 MKP AC 275 V, 0,1 uF, T100 EN 60384-14: 2005-08 VDE 40024537 MKP62 AC 275 V, 105K, T110 EN 132400; EN 60384-14 VDE 40000358 AC 275 V, 1,0 uF, T85 EN 132400; EN 60384-14 SEMKO SE/0256-2 X2 capacitor 1# X2 capacitor 1# (Alternative) X2 capacitor 1# (Alternative) Xiamen Faratronic Co., Ltd. OKAYA Electric Industries Co., Ltd. Anhui Xinyang electronics Co., Ltd. W8283BW X2 Capacitor 2# Xiamen Faratronic Co., Ltd. X2 Capacitor 2# (Alternative) Pilkor Electronics PCX2 335M Co., Ltd. TRF No. IEC60335_2_40F Page 35 of 41 Report No. GZES120900879606 IEC 60335-2-40 X2 Capacitor 2# (Alternative) Anhui Xinyang Electronics Co., Ltd. MKP AC 275 V, 1,0 uF, T100 EN 60384-14: 2005-08 VDE 40024537 PTC Resistance Gaoli Electronic Branch of Huagong Tech Co., Ltd. MZ8IVB470N R=47Ω±20%; Ts=120±10℃ ; Umax=275VAC; Imax=8Arms EN 60335-2-40 EN 60335-1 Tested with appliance PTC Resistance (Alternative) Dandong Guotong Electronic MZ-47R-A Components Co., Ltd. R=47(1±20%) EN 60335-2-40 EN 60335-1 Tested with appliance IEC 61051-1 IEC 61051-2 IEC 61051-2-2 CECC 42000/A1 CECC 42200/A1 CECC 42201/A1 IEC 61051-1 IEC 61051-2 IEC 61051-2-2 CECC 42000 CECC 42200 CECC 42201 Varistor Chengdu Tieda Electroni Co., Ltd. MYN15-621K AC 385 V, T85 Varistor (Alternative) Xianhua Advanced Technology Holding) Co., Ltd. FNR-14K621 AC 380 V, T85 Optocoupler 1# Toshiba Corporation TLP781 Vceo: 80 V; If: 60 mA; Ic: 50 mA DIN EN 60747-5- VDE 2: 2003 40021173 Optocoupler 2# Sharp Corporation PC817 Vceo: 80 V; If: 50 mA; Ic: 50 mA DIN EN 60747-5- VDE 2: 2003 40008087 Optocoupler 3# AVAGO TECHNOLOGIE S MANUFACTURI NG (SINGAPORE) PTE. LTD HCPL-817 130%
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Modify Date : 2013:07:25 09:55:54+08:00 Create Date : 2013:07:01 17:15:50+08:00 Metadata Date : 2013:07:25 09:55:54+08:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Creator : Wing_Pan Title : Document ID : uuid:5f2b1fad-b515-4a21-9e38-0857ca11e3ce Instance ID : uuid:4e5b9791-d7a8-4ab5-8789-cd70386cdfda Producer : Acrobat Distiller 10.1.4 (Windows) Page Count : 43 Author : Wing_PanEXIF Metadata provided by EXIF.tools