CPC 100 Manual Brochure ENU 1
CPC-100-Manual-Brochure-ENU CPC-100-Manual-Brochure-ENU
CPC-100-Manual-Brochure-ENU-1-1 CPC-100-Manual-Brochure-ENU-1-1
CPC-100-Manual-Brochure-ENU-2 CPC-100-Manual-Brochure-ENU-2
CPC-100-Manual-Brochure-ENU-4 CPC-100-Manual-Brochure-ENU-4
CPC-100-Manual-Brochure-ENU-3 CPC-100-Manual-Brochure-ENU-3
User Manual: CPC-100-Manual-Brochure-ENU-1
Open the PDF directly: View PDF
.
Page Count: 44
| Download | |
| Open PDF In Browser | View PDF |
CPC 100 Multi-functional primary test system for substation commissioning and maintenance CPC 100 – The revolutionary all-in-one test system The patented test system replaces numerous individual testing devices and offers new, innovative testing methods. This makes testing with the CPC 100 a timesaving and cost-effective alternative for conventional testing methods. Despite its expansive capabilities, the CPC 100 is very simple to use. Turns ratio meter for transformers, CTs and VTs The powerful testing device provides up to 800 A or 2 kV (2 kA or 12 kV with accessories) with up to 5 kVA over a frequency range of 15 Hz to 400 Hz or 400 ADC. Its compact design (29 kg / 64 lbs) makes it easy to transport and ideal for on-site testing. High-current injection transformer Using the CPC 100, electrical tests on various assets can be performed: >> Current transformers >> Voltage transformers >> Power transformers Power meter (P, Q, S) >> Power lines >> High-voltage (HV) cables >> Grounding systems >> Rotating machines >> GIS systems >> Switchgear and circuit breakers >> IEC 61850 installations Excitation curve tester >> Protection relays 2 kV 12 kV (with booster) Quality & Experience The usage of high-quality components & intensive routine testing in our factory have made the CPC 100 a reliable companion for for our customers worldwide. Phase angle meter The CPC 100 is being improved continuously in close cooperation with our customers. Its new accessories and continuous updates guarantee a future proof concept. Line impedance and cable measurement On load tap changer test equipment 2 Ground resistance meter Micro ohmmeter 400 ADC Tester for Rogowski coils and other unconventional CTs / VTs (IEC 61850) 29 kg / 64 lbs single phase wall outlet Winding resistance meter Protection relay tester (one phase V, I, f) 400 A DC Multimeter (V, I, R, Z, ...) 800 AAC 2 kA (with booster) Step up transformer 2 000 V Complex impedance meter (burdens, cables, lines and transformers) 15 Hz - 400 Hz Vector group verification system for power transformers Polarity checker Power / dissipation factor measurement set 3 9 good reasons for one system >> Test several assets (e.g. CT, VT, CB, power transformer) >> Test different parts of an asset (e.g. core, windings, bushing, insulation) >> Perform numerous tests >> Voltage and current injection with variable frequency (e.g. ratio, polarity, burden, excitation current) >> Suppression of mains-related interference and disturbances >> Test results at different frequencies provide more detailed information about an asset >> Variable frequency testing is necessary for some standardized and advanced diagnostic tests >> Offline test preparation possibilities (time-saving and less error-prone) >> CPC 100 software automatically guides the user through the test >> Automated report generation >> Light-weight (29 kg / 64 lbs) >> Customizable test reports >> Compact design (e.g. different languages, customer logo) >> Save costs on: > Transport > Handling > Storage >> CPC 100 fulfills highest safety requirements >> CPC 100 is CE tested >> CPC 100 tests according to IEEE and IEC standards >> Measurements with the CPC 100 deliver reliable and repeatable results due to high signal and measurement accuracy 4 >> Durable case design for rough environments with test field accuracy >> Long lifetime due to high quality components >> Premium quality cables and clamps >> Comprehensive documentation (e.g. user manual with connection diagrams, software help function, videos, application notes) >> Further applications can be covered by adding additional hardware accessories >> By upgrading the software: > Additional tests can be performed > Additional assets can be tested >> Emergency switch-off button >> Ground connection check >> Overload detection >> Multiple isolated outputs >> Safety key lock >> Discharge circuit to de-energize DC test objects >> Strobe light >> 3-position safety switch >> Grounding box >> Unconventional assets can be tested (e.g. Rogowski coils, low power CTs) >> Testing according to IEC 61850-9-2 (e.g. Sample Values, Merging Unit testing) >> Future applications areas will be covered by newly developed accessories and software 5 CPC 100 product family – Extended range of applications The CPC 100 covers a lot of different applications in and around substations as well as at the manufacturer’s production site. Extended by a high number of valuable accessories the application range of the CPC 100 is further expanded. Thus it is the ideal instrument for all major applications in the area of primary testing. CPC 100 Applications Current transformer testing (page 8 – 9) Voltage transformer testing (page 10 – 11) Power and distribution transformer diagnosis (page 12 – 13) Grounding system analysis (page 16 – 17) Switchgear / circuit breaker testing (page 22 – 23) Primary test system Commissioning protection systems (page 24 – 25) Sampled Values testing (page 26 – 27) 6 Extended range with accessories HV cable and power line analysis (page 14 – 15) Grounding box Grounding system analysis (page 16 – 17) Coupling unit Handheld grounding tester HV-source Remote control Power and distribution transformer diagnosis (page 12 – 13) Switchgear / circuit breaker testing (page 22 – 23) Switch box Rotating machine diagnosis (page 18 – 19) Compensation reactor Voltage transformer testing (page 10 – 11) Tan Delta test set (power factor) Current transformer testing (page 8 – 9) Sampled Values testing (page 26 – 27) Current booster Gas Insulated Switchgear testing (page 20 – 21) Resonance circuit 7 M/G Current transformer (CT) testing Why testing CTs? CT testing with the CPC 100 Testing current transformers helps to detect installation related and in-service related problems, such as: Supplied from a single phase wall outlet, the CPC 100 can generate up to 800 A AC (2 000 A with CP CB2 current booster) for injecting into the CT‘s primary side and testing its ratio, polarity and burden. Installation related >> Transportation damages Excitation curve measurement >> Wiring errors For excitation curve measurement, the CPC 100‘s output is connected to the secondary terminals of the core. Within an automatic test run, the CPC 100 measures the excitation curve and displays the knee point voltage and knee point current at rated frequency (according to the relevant IEC or IEEE / ANSI standard). The CPC 100 also automatically demagnetizes the CT core after the test. >> Manufacturing defects In-service related >> Degradation of accuracy class >> Shorted turns >> Magnetized core >> Burden failures in secondary circuit >> Insulation material failures With the CPC 100 many standard electrical tests for CTs can be performed with one single device saving testing time and labor costs. Additionally, unconventional CTs, like Rogowski coils and IEC 61850 integrated systems, can also be tested. + CPOL2 The CPOL2 can check the correct polarity along the different connection points in the secondary wiring by analyzing the sawtooth signal injected into the CT’s primary side using the CPC 100. Your benefits >> Mulifunctional CT tests >> Primary injection up to 2 kA >> Simple wiring test with handheld polarity checker (CPOL2) >> Voltage withstand test up to 2 kV 8 Winding resistance measurment Current transformer testing Using the winding resistance measurement function also allows the user to calculate the accuracy limiting factor (ALF) for protection circuits and the instrument security factor (FS) for metering circuits. >> CT ratio (with burden) up to 800 A or 2 000 A with CP CB2, 5 kVA output power >> CT burden up to 6 A AC | secondary Power/dissipation factor (PF/DF) measurement >> CT excitation curve When combined with the CP TD1, the CPC 100 is also capable of performing PF/DF measurements. This helps to assess the insulation condition of the CT. (knee point) up to 2 kVAC >> Polarity check with CPOL2 up to 800 A or up to 2 000 A with CP CB2 >> Accuracy limiting factor (ALF) test >> CT ratio with voltage up to 130 VAC | bushing CTs > CT winding resistance up to 6 ADC >> CT demagnetisation and remanence >> CT voltage withstand test up to 2 kVAC >> CT ratio Rogowski and CT ratio low power up to 800 A or up to 2 000 A with CP CB2, 5 kVA output power >> Power/dissipation factor test up to 12 kV, 300 mA | with CP TD1 >> IEC 61850 Sampled Values testing + CP CB2 + CP TD1 With the CP CB2 primary injection of current up to 2 kA can be realized for CT testing. For high-voltage CTs, insulation material tests are very important and can be easily done with the CP TD1 accessory. 9 Voltage transformer (VT) / potential transformer testing Why testing VTs? VT testing with the CPC 100 The majority of VT failures occur due to electrical stresses or manufacturing and installation errors. Typically electrical stresses are caused by: With a voltage output of up to 2 000 VAC the CPC 100 can be used to test VT ratio, polarity and burden. By injecting voltage into the primary side, ratio can be measured. Thereby the phase angles of high-voltage output and voltage measurement input are also measured. Thus the correct VT polarity can be verified. >> Thunderstorms >> Ferro-resonances effects >> Over-voltages Applying voltage to the secondary VT circuits and measuring the load current in amplitude and phase allows the actual burden to be measured, ensuring that it is within the VT´s specification data. Especially in high-voltage and extra high-voltage installations supervision of the VT insulation system is important to ensure that its dielectric characteristics have not degraded over time. In case of (re-)commissioning of substations VT circuits should also be checked. Verifying the VT´s nameplate data helps to identify damages of the VT or wrong connections. Your benefits >> Ratio testing from 15 Hz - 400 Hz >> Multi-functional VT testing >> Simple wiring check with handheld polarity checker (CPOL2) 10 Disturbance-free measurement Voltage/potential transformer testing The VT‘s secondary signal may be difficult to measure if it is small in amplitude – especially if neighboring parts of the substation are in operation. In case of strong disturbances, the user can select a frequency different to that of the power system and utilizes the “frequency selective measurement” function. Thus only the VT‘s output signal with this particular frequency is measured while all other signals are filtered out. >> VT ratio up to 2 kVAC | polarity and burden >> VT burden up to 130 VAC | secondary >> VT secondary voltage withstand test up to 2 kVAC >> Polarity check with CPOL2 up to 2 kVAC >> VT electronics up to 2 kVAC >> IEC 61850 Sampled Values testing >> Power/dissipation factor test up to 12 kV, 300 mA | with CP TD1 + CPOL2 + CP TD1 The CPOL2 can check the correct polarity along the different connection points in the secondary wiring by analyzing the sawtooth signal injected into the VT’s primary side using the CPC 100. For high-voltage VTs, insulation material tests are very important and can be easily done with the CP TD1 accessory. 11 Power transformer testing Testing power transformers – Most common electrical tests with one device Winding resistance measurement The CPC 100 provides an easy and accurate (4-wire connection) winding resistance measurement. Automatic measurement for tapped windings (by using CP SB1 with the on load tap changer) speeds up the measurement. The CPC 100 automatically discharges the inductive energy, which makes the measurement safe. Testing to assess the health of power transformers and to diagnose problems is of utmost importance to ensure the long-term and safe operation of these very expensive power assets. With the CPC 100 power transformers and their ancillary components can be tested: Demagnetisation >> Windings After switching off a transformer or after applying DC signals to a transformer, the core remains magnetized. This can cause problems for further diagnostic measurements or can lead to higher inrush currents. By using the CP SB1 switch box the integrated algorithm in the CPC 100 completely demagnetizes the transformer core. >> Tap changer >> Bushings >> Insulation >> Core >> Connection leads >> Surge arrestors Ratio & excitation current measurement For measuring ratio and excitation current, the CPC 100 provides a 2 kV output, delivering 2500 VA. The test voltage is generated digitally and the current is automatically measured within the CPC 100. This makes the measurement highly accurate, easy to set up, fast and safe. Your benefits >> Most common power transformer tests with one device >> Fully automated testing with switchbox CP SB1 >> Advanced tap changer diagnostics using OLTC scan (DRM) >> Effective core demagnetization 12 Power/dissipation factor (PF/DF) measurement Power transformer testing For PF/DF measurement on power transformers and bushings, the CPC 100 is combined with the CP TD1. Measuring this factor over a broad frequency range – in addition to mains frequency – helps to better assess the insulation condition, for example detect whether the cellulose or the oil is contaminated by moisture. >> DC winding resistance (up to 100 ADC) >> Transformer demagnetization (with CP SB1) >> Dynamic load tap changer diagnostics (on load tap changer test) (up to 100 ADC | optionally with CP SB1) >> Transformer turns ratio (TTR) per tap up to 2 kVAC | including polarity and excitation current | Dynamic resistance measurement (DRM) IEC 61387-1 support for transformer with unconventional vector groups The DRM can be performed as a supplementary measurement in order to analyze the OLTC’s switching process. The CPC 100 + CP SB1 injects a DC current in the same way that it does for static winding resistance measurements with the the addition of recording the dynamic behaviour of the diverter switch. Based on this non-invasive testing method, failures can be detected without opening the OLTC compartment. >> Automatically determination of the transformer’s vector group (with CP SB1) >> Leakage reactance / short circuit impedance (up to 6 A AC) >> Transformer, bushing: power/dissipation factor + insulation capacitance up to 12 kV, 300 mA | frequency from 15 Hz to 400 Hz | with CP TD1 >> Insulating fluids: power/dissipation factor up to 12 kV, 300 mA | with CP TD1 and CP TC12 >> Excitation current per tap (up to 12 kV, 300 mA | with CP TD1) >> Frequency response of stray losses (FRSL) >> Surge arrestors: leakage current and watt losses up to 12 kV, 300 mA | with CP TD1 >> HV source for voltage withstand test up to 15 kVA | with 3 CPCs + TRC1 >> HV source for PD measurements up to 15 kVA | with 3 CPCs + TRC1 + CP SB1 + TRC1 + CP TD1 The switchbox CP SB1 reduces wiring work at power transformers. Thereby, the time needed for testing can be reduced and, at the same time, safety can be significantly increased. The triple remote control TRC1 allows three CPCs to be synchronized safely. This allows the CPC 100 to be used as a powerful HV source. Matching transformers are provided in order to match the rated voltage on the LV side. Insulation condition assessment of transformers, bushings and insulation fluids (with the CP TC12). HV-source 13 Line impedance measurement X in Ω Line parameters for distance protection Zone under- and overreach L in e im p Ph e da Fau ase -t n ce o Z im l t : C - gr L p e alc o u da n u n c e l a te d d ms e 1, Zo n Zo n e 2, These parameters are often calculated from software tools, which do not provide actual line parameters due to unknown soil properties, such as different soil resistivities, pipelines or other unknown conductors. This leads to under- or overreach of your distance protection relay resulting in outage and loss of grid stability. t1 = 0 t = 2 30 0 m s Correct line parameters are crucial for reliable and selective distance protection. The set of parameters contains the positive and the zero sequence impedance (Z1, Z0) as well as the k-factor (kL, RE/RL and XE/XL, k0). 100 % of Line length R in Ω The most frequent faults on power lines are ground faults. In particular, inaccuracies from software calculation effect this kind of fault. The example on the right shows a zone overreach for a ground fault due to an incorrect k-factor setting. In this case the assumed k-factor is higher than the actual one. Therefore, a ground fault at the remote end of the line is seen incorrectly in the first zone. Incorrect k-factor (tendancy to overreach) Mutual coupling With this unique testing equipment, the mutual coupling impedance between parallel lines can also be determined to consider coupling effects for correct parameterization. Your benefits >> Accurate distance protection relay settings by performing a line impedance measurement >> Safe and quick determination of Z1, Z0 and k-factors >> Mutual coupling impedance measurement between parallel lines Ground grid 14 Testing with the CPC 100 Cable and transmission line diagnosis The main unit CPC 100 generates the frequency variable test current and measures current and voltage by applying digital filtering for high accuracy. The complex loop impedance is then calculated accordingly. >> Line impedance and k-factor up to 100 A | with CP CU1 >> Mutual coupling The CP CU1 provides galvanic isolation between the line under test and the CPC 100 as well as impedance matching for short and long lines. up to 100 A | with CP CU1 >> Positive or zero sequence impedance The CP GB1 protects the test equipment and the user from any unexpected overvoltage on the line under test. Furthermore it allows a direct connection to the power line for a convenient execution of the test. A dedicated test template provides the positive and the zero sequence impedance as well as the k-factor in commonly used formats. Furthermore it shows the actual zone reach for each fault type based on the measured values and relay parameters that are currently being used. + CP CU1 The CP CU1 allows the safe connection of the CPC 100 to a power line or HV cable. The impedance matching transformer within the CP CU1 ensures optimum power transfer from the CPC 100 to the power line. Ground grid CP GB1 15 Grounding system testing Personnel safety Fall-of-potential measurement (3-point test) In the event of a ground fault hazardous step and touch voltage can occur inside and outside of a substation. Ground tests prove the effectiveness of grounding systems and guarantee safety of people inside and outside the substation. The fall-of-potential measurement with the CPC 100 is performed according to EN 50522 or IEEE 81. For the fall-of-potential measurement the voltage between the ground grid and ground electrodes in different distances to the ground grid is measured until reference ground is reached. Dedicated software transforms the test results into a voltage and impedance chart which allows the ground potential rise and the ground impedance to be determined. A fall-of-potential measurement is usually performed to determine the condition of the entire ground grid. On top of that, step and touch voltages are measured at exposed locations in order to ensure human safety in select areas. Your benefits >> Determine true test values by power line injection Ground grid >> Simple and accurate step and touch voltage measurements with handheld HGT1 device >> Reduction factor measurement on ground wires and cable shields 16 Step and touch voltage measurement Ground system analysis Step and touch voltage measurements according to EN 50522 and IEEE 81 are performed with the HGT1. This handheld device employs frequency selective measurements for effective noise suppression. >> Ground grid impedance for large systems up to 100 A | with CP CU1 >> Step and touch voltage Furthermore, tests can be executed quickly and easily since long test cables for connecting to the main device are no longer necessary. up to 100 A | with CP CU1 and HGT1 >> Ground grid impedance for small systems up to 6 A AC >> Soil resistivity Dedicated test templates assess measured step and touch voltages according to EN 50522 and IEEE 80 automatically. up to 6 A AC >> Integrity check of grounding connection up to 400 ADC >> Reduction factor / current split factor >> Measure multiple current paths with Rogowski coil + HGT1 Primary Test Manager (PTM) and HGT1 enable you to quickly, simply and conveniently measure ground impedance as well as step and touch voltage. Due to a new approach there is no operational personal required at the CPC 100 anymore. Together, the test director and assistants perform all measurements out in the field in order to avoid miscommunication and selection of inadequate test points. Ground grid CP GB1 When testing large ground grids the potential of the ground grid under test and the counter electrode must not overlap. This is done in order to ensure human safety in a worst case scenario, which is always crucial. The CPC 100 + CP CU1 overcomes this problem by injecting the test current into a remote substation via an existing power line. 17 Rotating machines diagnosis Why test rotating machines? PF/DF measurement and PF/DF tip-up test Rotating machines, such as motors and generators, are highly important components in power generation and industrial applications. Therefore machine reliability and availability are in high demand. Motors and generators are exposed to high thermal, mechanical and electrical stress that influences their reliability and life expectancy. The PF/DF measurement is used as a maintenance tool for entire windings. The portable solution CPC 100 + CP TD1 + CP CR500 allows PF/DF measurements to be carried out at nominal frequency. The measurement results can be compared with previous measurements, factory acceptance tests or a phase-tophase comparison can be made. An acceptable PF/DF offers assurance that the insulation condition allows reliable operation. Premature failure may lead to significant economical losses, due to unexpected outages and possible damage to the asset itself. In order to plan maintenance effectively, it is essential to have accurate condition information about when components need to be repaired or replaced. Furthermore, a parallel partial discharge measurement allows for a more detailed diagnosis of the type of fault. The CPC 100 + CP TD1 can be used as HV source for the partial discharge measurement. A variety of electrical tests can be performed with the CPC 100 over the complete life cycle of machines to increase their reliability, prevent premature failures and to extend reliable service life. The measurement complies with international standards such as IEC 60894 and IEEE 286. Your benefits >> Portable HV source >> High accurate PF/DF measurement with reference capacitance for maximum usability >> Defined voltage steps for a combined partial discharge and PF/DF measurement enable reproducible test conditions 18 DC winding resistance measurement Rotating machines diagnosis A DC resistance measurement is performed to detect possible contact problems in the stator and rotor winding of a machine. >> Power/dissipation factor tip-up test at 50 Hz / 60 Hz up to 12 kV | 5 A| with CP TD1 and CP CR500 The CPC 100 offers an integrated micro ohmmeter with a maximum output of 400 A. The 4-wire method is used to detect connection problems in the stator winding (bad soldering contacts) as well as contact problems on the pole connectors of the rotor winding. >> Power/dissipation factor test with variable frequency up to 12 kV | frequency from 15 Hz to 400 Hz | with CP TD1 >> HV source for testing rotating machines up to 12 kV | max. 2 µF | with CP TD1 and CP CR500 Both failures can be the root cause of a local hotspot and potentially damage the machine. >> DC winding resistance measurement up to 400 A DC and 5 kVA down to the microohm range. >> Pole drop test Pole drop test Mechanical stress in rotor windings cause inter turn faults (short circuits), which can lead to a magnetic imbalance. This causes higher shaft vibrations which puts more stress on the bearings and can potentially damage them. The CPC 100 provides the AC source and the accurate voltage inputs nedded to perform the pole drop test. + CP CR500 + CP TD1 The CP CR500 compensator reactor enables the CP TD1 to be used with test objects with large capacitance such as large motors and generators. Insulation condition assessment of motors and generators. The CPC 100 + CP TD1 can provide up to 12 kV. It can be be used as HV source and PF/DF measurement system at the same time. 19 Gas-insulated switchgear testing Testing gas-insulated switchgear to date Innovative GIS testing Gas-insulated switchgears (GIS) are compact and are, therefore, used in applications where space is limited. For commissioning of GIS a high-voltage (HV) withstand test is required in accordance with standards (IEC 62271-203). With the CPC 100 + CP RC it is possible to perform GIS tests without the need of a big HV transformer. This is possible because the system directly makes use of a specially designed “Power VT” for testing. To date the test voltage needed for a withstand test has been produced by a resonance circuit. This test system consists of an HV test transformer, a coupling capacitor and a power control unit. The HV test transformer and the coupling capacitor have to be connected directly to the GIS. This Power VT is an integral part of the GIS and generates the required test voltage. CPC 100 injects power at the LV side of the VT, producing the necessary voltage on the HV side. A direct connection of the measuring system to the integrated VT of the GIS system eliminates the need for draining and refilling any SF6 gas. Weak points of this testing principle: The CPC 100 + CP RC system comprises several small and light-weight components (< 21 kg / 46 lbs) which can be transported by one person. With its modular design GIS tests can even be accomplished at test sites with limited space. >> The complete test system is difficult to transport, because it consists of very heavy and large components. >> It is difficult to use it at test sites with limited space, such as wind turbines. >> The HV test lead must be connected to, and disconnected from, the GIS system for testing. This normally includes a time-consuming venting and refilling process of the SF6 gas. Your benefits >> Small and light-weight test system with high output power >> Testing without gas venting and refilling procedure >> Automatic frequency tuning for ideal load compensation 20 Powerful voltage withstand testing GIS testing When combined with the CP RC1, the CPC 100 allows withstand tests with a maximum test voltage of 200 kV to be carried out on GIS systems up to a rated voltage of 123 kV. The CPC 100 + CP RC2 is appropriate for testing GIS systems with a rated voltage of up to 145 kV and a maximum test voltage of 235 kV. This package is supplied with the additional CP AT1 auto-transformer to guarantee the necessary output power of the CPC 100 for higher loads. >> Withstand test up to 235 kV | max 1.6 nF | with CP RC2 >> HV source for partial discharge measurements up to 235 kV | max 1.6 nF | with CP RC2 HV source for partial discharge measurements During production or maintenance, impurities can occur in GIS. These can cause major problems in operation. Therefore, it is recommended to perform a partial discharge measurement during commissioning (acceptance tests). While performing these measurements with our MPD series the CPC 100 + CP RC can be used as the HV source. + CP CR + CP TR + CP AT1 With the compensating reactor 4 mH CP CR4 or 6 mH CP CR6 the CP CR compensates the capacitance in a modular fashion. The isolation transformer CP TR provides a potential-free output signal and compensates the capacitive load. The auto-transformer CP AT1 allows to connect the mains supply of the CPC 100 to a three-phase 16 A power outlet, and delivers the required power for the test setup. 21 Switchgear and circuit breaker testing Why test switchgear and circuit breaker? Contact resistance measurement Switchgear consists of busbars, circuit breakers (CB), disconnectors and earthing switches. There are various connections and contacts within the switchgear. Poorly maintained or damaged contacts can cause arcing, single phasing or even fire which can lead to the total loss of the asset. The CPC 100 can measure contact resistance by injecting a current of up to 400 ADC into the contacts and measuring the voltage drop (using the 4-wire method). The resistance value can be compared to the value given by the manufacturer as well as to previous records. Therefore, it is common practice to conduct contact resistance measurements to ensure that the connections have been made with the appropriate contact pressure. Additionally, the insulation of CBs within the switchgear has to be tested. These assets are frequently exposed to HV stresses, switching currents and very high fault currents, which heat up the circuit breakers and impact on the insulation material. Your benefits >> Contact resistance testing with up to 400 A DC >> Power/dissipation factor measurement >> Testing of entire chain from the CT to the CB's main contacts 22 Insulation testing of circuit breakers Switchgear / circuit breaker testing For power/dissipation factor measurements on CBs, the CPC 100 is combined with the CP TD1. Measuring this factor over a wide frequency range – in addition to mains frequency – helps to better assess the insulation condition. >> Contact resistance up to 400 ADC >> Bushing: power/dissipation factor (tan δ) + insulation capacitance 12 kV, 300 mA | frequency from 15 Hz to 400 Hz | with CP TD1 >> Circuit breaker: power/dissipation factor (tan δ) up to 12 kV, 300 mA | frequency from 15 Hz to 400 Hz | with CP TD1 >> Insulating fluids: power/dissipation factor (tan δ) up to 12 kV, 300 mA | with CP TD1 and CP TC12 + CP TD1 CPC 100 Insulation condition assessment of circuit breakers and insulation fluids (with CP TC12). μΩ measurement with the CPC 100‘s 400 ADC capabilities enables accurate contact resistance measurements on circuit breakers. 23 Commissioning and trouble shooting of protection systems Commissioning protection systems CT & VT performance check In order to work properly, protection and control systems have to be correctly integrated into the substation or power plant. Quantities from the primary system are transformed at the VTs and CTs – using their different cores – and so the voltage and current signals must be correctly connected to the protection relays, automation units and meters. The CPC 100 allows the verification of the ratio and polarity of CTs and VTs – preventing wrong connections, especially in the case of tapped CTs. Injecting current or voltage into individual CTs / VTs and checking the reading at the relay ensures that phases are not mixed up and that the CT and VT ratio setting in the relay is correct. The CPC 100 can also measure the burden on the CTs and VTs and, by determining the CT’s excitation curve, it ensures that the protection circuits are connected to the appropriate CT cores. From these protection and control units, the trip signals are routed back to the primary apparatus, for example, the circuit breakers. A fault in any part of this system may result in a system failure – false tripping or a failure to trip. Wiring check To prevent such a failure, the system’s functionality can be verified by injecting into the primary side of the CT or VT and checking the measured values at the relay or automation unit. Finally, injecting current at the magnitude of a fault should result in the tripping of the circuit breaker, which allows the verification of the complete chain. The CPC 100 can help to verify that the secondary wiring is correct. By injecting a sawtooth signal into the CT or VT, the operator verifies with a handheld device that the signal has the correct polarity at the connection points of the secondary systems. CB Busbar Your benefits >> Testing of entire chain from the CT to the CB's main contacts >> Versatile due to high-current and high-voltage outputs Relay >> Wide range of applications covered Control room 24 Wiring terminal Wires Timing of CBs with overcurrent elements Protection installation testing For testing of CBs or load breaker switches with integrated overcurrent elements, the CPC 100 can inject AC primary currents up to 800 A (or 2000 A together with the current booster CP CB2), and measure the time from the start of the injection to the interruption of the current. >> CT ratio (with burden) up to 800 A or 2000 A with the CP CB2, 5 kVA output power >> CT burden up to 6 A AC | secondary >> CT excitation curve (knee point) Primary injection up to 2 kVAC With the CPC 100 primary faults can be simulated to check if overcurrent, differential or distance relays operate correctly. The total trip time including the CB operating time can also be measured in this test. >> VT ratio up to 2 kVAC | polarity and burden >> VT burden up to 130 VAC | secondary >> Overcurrent relays with primary injection (MV) up to 800 A or 2000 A with the CP CB2, 5 kVA output power >> Polarity check with CPOL2 up to 800 A or 2 kVAC , 5 kVA output power >> Testing of the entire protection chain by primary fault current injection and live CB tripping VT CT + CPOL2 CPC 100 The CPOL2 can check the correct polarity along the different connection points in the secondary wiring by analyzing the sawtooth signal injected into the VT’s and CT´s primary side using the CPC 100. The CPC 100 can inject up to 800 A (2 000 A with the CP CB2) or up to 2 kV as well as a sawtooth polarity check signal into CTs or VTs in the HV yard, hence performing testing on the whole system. Wiring terminal HV yard 25 IEC 61850-9-2 Sampled Values testing IEC 61850 Sampled Values The standard for “Communication Networks and Systems for Power Utility Automation”, IEC 61850, utilizes network technologies for all types of information exchange. A merging unit (MU) collects the measured current and voltage values from the current and voltage sensors. Then it merges the digitized values, which are called “Sampled Values” (SV), into a data stream published to the substation network. Within IEC 61850, protocols for the transmission of instantaneous voltage and current values are specified. The sensors used in the transmission process can be conventional CTs and VTs as well as unconventional current and voltage sensors. Using this method, measured values (for example, the bus voltage for a busbar protection scheme) can easily be distributed to multiple bay devices. 0111000 Your benefits 800 A 2 kV >> Ready for applications in digital substations >> Closed loop testing of merging units >> Primary injection works independently of the sensor technology used 26 CT Sampled Values testing with the CPC 100 Sampled Values testing The CPC 100 test system performs closed-loop testing whereby a test signal is injected on the primary side of the current / voltage sensors. The MU converts the sensor output into a SV stream which is published to the substation network. The CPC 100 then reads the data back from the network in order to perform a variety of different tests. >> SV CT ratio test and polarity check up to 800 A or up to 2 000 A , 5 kVA output power | with the CP CB2 >> SV VT ratio test and polarity check up to 2 kVAC >> Automatic MU detection >> Automatic voltage / current channel detection Automatic MU and channel detection is achieved by injecting a test signal with a specific wave form. An optimized and time-effective algorithm searches for the unique test pattern within all the available MUs on the network to identify the correct channel for testing. >> Frequency selective voltage / current meter >> Noise level measurement >> Amplitude response of the signal processing chain up to 800 A or up to 2 kVAC | frequency from 15 Hz to 400 Hz The CPC 100’s SV test card operates according to the “Implementation Guideline for Digital Interface to Instrumental Transformers using IEC 61850-9-2” published by the UCA International User Group. CPC 100 0001 The CPC 100 injects a sinusoidal test signal to perform tests such as the ratio test. Additionally, the CPC 100 generates specific periodic wave shapes to identify the correct MU and corresponding test channel. Closed-loop testing 0111000001 MU VT Substation Network CTs, VTs and unconventional sensors 27 Operation of CPC 100: front panel Operating from the front panel Selecting test cards directly The test template can be seen as a test plan. It tells the user which measurements to make and provides the basis for the overall test report. Operating the CPC 100 manually provides the quickest results with minimal training and preparation – perfect for users who only operate the device occasionally. The user just selects the test card to be used, connects the CPC 100 to the asset and performs the test by pressing the start button. Test templates can be prepared in advance in the office on the PC – without the CPC 100 connected – and can then be executed on site, step by step. Users can also create their own test templates and define, which test cards they want to include. Using pre-defined test templates The settings and results of all manual tests can be stored on a flash memory and transfered to a PC using a USB memory stick or ethernet connection. Additionally, pre-defined test templates help the user to perform frequently used tests conveniently and efficiently. A number of test cards (for example, power/dissipation factor, winding resistance, ratio measurement, etc.) are combined into one test template. An example is the template containing all the recommended measurements for testing a current transformer. CPC 100 test card 28 Customized reporting: Microsoft Excel™ Different ways to operate After transferring the test results to a PC, report templates in numerical and graphical form are available. The CPC 100 offers different operating modes, to meet the personal preferences of the user: The measurement data – including settings and results as well as administrative information such as date and time, filename, etc. – can also be imported to these templates for customized reporting, graphical result evaluation and further analyses. >> From the front panel: Selecting test cards directly >> From the front panel: Using pre-defined test templates Microsoft Excel™ reports provide the basis for clientspecific reporting and allow test reports to be adapted to utility or manufacturer specific formats. Further content, such as company logos, can also be added. >> Fully automated: Using Primary Test Manager™ (see next page) Test reports can then be printed in a variety of languages. Test template with test cards Test report 29 Step by step through the test procedure with Primary Test ManagerTM Managing location, asset and test data The Primary Test Manager (PTM) software solution makes it possible to perform a multitude of tests on power transformers, circuit breakers, and current transformers. It provides active guidance for the user during the process of testing with the CPC 100, making tests faster, easier, and safer. PTM provides a well-structured database for managing test results and getting a comprehensive overview of the asset's condition. Locations, assets, jobs and reports can be defined and managed quickly and easily. TM Import and export functionality PTM supports data exchange between different test systems. Data can be imported easily in the PTM database. In addition, they can be filtered or exported in common formats (XML, PDF, Microsoft Word™, Microsoft Excel™). Data synchronization and back-up During on-site testing, data is often generated by multiple testing teams. With the ‘PTM DataSync’ module all data can be synchronized to a central database hosted on premises or in the cloud. In doing so, data synchronization and storage becomes safer and more convenient. The relevant locations can be selected in order to keep the local database small. Easy management of location, asset and test data due to a structured database, implemented search and filter functions and automatic data synchronization. 30 PTM supports in the best possible wiring diagrams and asset-specific Executing diagnostic tests Result analysis and reporting PTM helps to define the test asset with specific nameplate views. It indicates mandatory and recommended parameters, making data entry fast and easy. A real-time overview of the test results is given during the measurement and an instant “pass/fail” assessment of the test results is displayed based on specified limit values. Based on the nameplate values, PTM generates a customized test plan according to current standards and guidelines for each asset. This way PTM is able to provide you with a comprehensive test plan for assessing the condition of your asset thoroughly. PTM automatically generates reports including all assetrelated information and the tests that have been performed. This gives a comprehensive overview of the test object, test results and assessment. Comparison tools for detailed analysis Easy connection due to wiring diagrams For a detailed analysis, different test results can be compared side-by-side or trended over time. Users can choose between a time- and type-based comparison as well as a phase-based comparison. Pre-configured wiring diagrams based on selected assets help to set up the CPC 100 correctly. This minimizes the likelihood of measurement errors and speeds up the testing process. Customized, individual reports User can adapt reports to their needs in PTM. Reports can be generated in Microsoft Word™, Microsoft Excel™ and as a PDF file. They can be further adapted by e.g. compiling the included parts, providing comments or incorporating a company logo. way during execution of diagnostic tests via test plans according to international standards. For a comprehensive analysis, PTM offers automatic result assessment and comparison as well as customized reporting. 31 Front panel and connection possibilities 4 1 11 9 5 15 16 2 19 12 13 3 6 7 10 8 17 14 18 1. Grounding terminal 9. 6 A or 130 V output 2. High AC voltage output 2 kV AC 10. 3. External booster output 11. Current measuring input 10 A AC or DC 4. High DC current output 400 A DC 12. Voltage measuring input 300 V AC 5. High AC current output 800 A AC 13. Low level voltage measuring input 3 V AC 6. Mains power supply 14. 7. Overcurrent protection 15. Binary input for potential-free contacts or Current output 6 A DC Voltage measuring input 10 V DC voltages up to 300 V DC 8. Power switch 32 16. Safety key lock 17. Signal lights 18. Emergency stop button 29 28 30 21 20 31 32 22 23 25 24 26 27 19. Keys for the quick selection of applications 29. 20. Keys for the quick selection of the desired view 30. Plug to connect external safety functions 21. LCD monitor 31. Socket for the connection of the CPC 100 22. Soft-touch keys which change their function according to the selected application to a network or direct connection to a PC’s network connector 32. 23. Keys for selecting stacked test cards 24. Numerical keyboard 25. Advanced jog-dial hand wheel with “click” (Enter) function 26. Up / down keys for navigation and entering values Serial interface for devices such as CP TD1 27. Test start / stop button 28. User manual 33 USB memory stick connection Technical data CPC 100 CPC 100 Generator / Outputs Inputs Current outputs Measuring inputs (Accuracy6) Vmax Powermax f Range Amplitude t 800 A AC 3 0 ... 800 A 25 s 6.0 V 4 800 VA 15 Hz ... 400 Hz 0 ... 400 A 8 min. 6.4 V 2 560 VA 15 Hz ... 400 Hz 0 ... 200 A >2h 6.5 V 1 300 VA 15 Hz ... 400 Hz 1 max 2 2 Input Imped. I AC / DC4, 7 < 0.1 Ω Amplitude Amplitude Phase Reading Error Full scale Error Full scale Error 10 A AC < 0.05 % < 0.05 % < 0.10° < 0.05 % < 0.05 % < 0.15° Range 10 6 A AC 0 ... 6 A >2h 55 V 330 VA 15 Hz ... 400 Hz 1 A AC 3 A AC10 0 ... 3 A >2h 110 V 330 VA 15 Hz ... 400 Hz 10 A DC < 0.03 % < 0.08 % – DC 1 A DC < 0.03 % < 0.08 % – 300 V < 0.05 % < 0.05 % < 0.10° < 0.05 % < 0.05 % < 0.10° 400 A DC 0 ... 400 A 0 ... 300 A 6 A DC 4, 10 2 min. 3 min. 6.5 V 6.5 V 2 600 VA 1 950 VA V1 AC DC 8 500 kΩ 0 ... 200 A >2h 6.5 V 1 300 VA DC 30 V 0 ... 6 A >2h 60 V 360 VA DC 3V < 0.10 % < 0.05 % < 0.10° 300 mV < 0.15 % < 0.05 % < 0.10° 3V < 0.03 % < 0.08 % < 0.10° 2 000 A AC 3 with an optional current booster (CP CB2) V2 AC 8, 11 10 MΩ Voltage outputs 300 mV < 0.08 % < 0.08 % < 0.10° 30 mV < 0.10 % < 0.25 % < 0.15° 10 V < 0.03 % < 0.08 % – Range Amplitude5 tmax Imax Powermax5 f 2 kV AC 3 0 ... 2 kV 1.25 A 2 500 VA 15 Hz ... 400 Hz 0 ... 2 kV >2h 0.5 A 1 000 VA 15 Hz ... 400 Hz 1V < 0.03 % < 0.08 % – 1 kV AC 3 0 ... 1 kV 1 min. 2.5 A 2 500 VA 15 Hz ... 400 Hz 100 mV < 0.05 % < 0.10 % – 0 ... 1 kV >2h 1.0 A 1 000 VA 15 Hz ... 400 Hz 10 mV < 0.05 % < 0.15 % – 0 ... 500 V 1 min. 5.0 A 2 500 VA 15 Hz ... 400 Hz 0 ... 500 V >2h 2.0 A 1 000 VA 15 Hz ... 400 Hz 0 ... 130 V >2h 3.0 A 390 VA 500 V AC 3 130 V AC10 1 min. V DC4, 7 Additional features of the measuring inputs Automatic range switching (except Amplifier test card) Galvanically separated potential groups: I AC/DC ; V1 & V2 ; V DC AC frequency range: 15 Hz to 400 Hz (except Amplifier test card) Protection of I AC/DC input: 10 A very fast acting (FF) fuse 4 15 Hz ... 400 Hz Internal measurement of outputs (Accuracy6) Amplitude Amplitude Phase Output Range Reading Error Full scale Error Full scale Error 800 A AC – < 0.10 % < 0.10 % < 0.10° 400 A DC – < 0.20 % < 0.05 % – 2 kV AC 2 000 V < 0.05 % < 0.05 % < 0.10° 1 000 V < 0.05 % < 0.05 % < 0.15° 500 V < 0.05 % < 0.05 % < 0.20° 5A < 0.20 % < 0.05 % < 0.10° 500 mA < 0.05 % < 0.05 % < 0.10° Binary input for dry contacts or voltages up to 300 V DC7 Trigger criteria: Toggling with potential-free contacts or voltages of up to 300 V Input impedance: > 100 kΩ Response time: 1 ms Output to input synchronization Test cards Quick, Sequencer, Ramping 34 Amplifier test card Frequency range 48 Hz ... 62 Hz 48 Hz ... 62 Hz Synchronization inputs V1 AC, V2 AC, I AC (fixed to maximum range) V1 AC (automatic range switch) Input magnitude 10 % of input range full scale Output magnitude 5 % of output range full scale Settling time 100 ms after 5 % of output range full scale is reached 1 000 ms after 5 % of output range full scale is reached Signal changes All quantities must be ramped within 20 signal periods No changes of frequency and phase. Magnitude changes without limitation. Output follows within 250 ms Phase tolerance 0.5 ° within the limits as specified above Resistance measurement 4-wire measurement with 400 A DC output and 10 V DC input Current Resistance Voltage Accuracy (full scale) 400 A 10 μΩ 4 mV Error < 0.70 % 400 A 100 μΩ 40 mV Error < 0.55 % All input / output values are guaranteed for one year within an ambient temperature of 23 °C ± 5 °C / 73 °F ± 10 °F, a warm-up time longer than 25 min. and in a frequency range of 45 Hz to 60 Hz or DC. Accuracy values indicate that the error is smaller than ± (value read x reading error + full scale of the range x full scale error). 400 A 1 mΩ 400 mV Error < 0.50 % 1. 400 A 10 mΩ 4V Error < 0.50 % With a mains voltage of 230 V using a 2 × 6 m high-current cable at an ambient temperature of 23 °C ± 5 °C / 73 °F ± 10 °F. 2. The power and maximum voltage may be reduced above 60 Hz or below 50 Hz. 3. Output can be synchronized with V1 AC in Quick, Sequencer, Ramping and Amplifier test cards. 4. The inputs and outputs are protected with lightning arrestors between the connector and against the protective earth. In the event of application of energy exceeding a few hundred Joule the lightning arrestors apply a permanent short-circuit to the input / output. 5. The power and amplitude may be reduced above 200 Hz or below 50 Hz. 4-wire measurement with 6 A DC output and 10 V VDC input Current Resistance Voltage Accuracy (full scale) 6A 100 mΩ 0.6 V Error < 0.35 % 6A 1Ω 6V Error < 0.35 % 1A 10 Ω 10 V Error < 0.25 % 2-wire measurement with 10 V VDC input Current Resistance > 5 mA 100 Ω Error < 0.60 % > 5 mA 1 kΩ Error < 0.51 % 6. 98 % of all units have an accuracy better than specified as “typical”. Error < 0.50 % 7. This input is galvanically separated from all other inputs. 8. V1 and V2 are galvanically coupled but separated from all other inputs. 9. There are power restrictions for mains voltages below 190 VAC. 10. Fuse-protected. 11. When using the CTRogowski test card, the 3 V V2 AC input uses an additional software based integration method. In the range of 50 Hz < f < 60 Hz, this results in a phase shift of 90 ° as well as an additional phase error of ± 0.1 ° and an additional amplitude error of ± 0.01 %. For frequencies in the range of 15 Hz < f < 400 Hz, the phase error is not specified, and the amplitude error can be up to ± 0.50 % higher. > 5 mA Voltage 10 kΩ Accuracy (full scale) Power supply and mechanical data Single-phase, nominal9 100 VAC ... 240 VAC, 16 A Single-phase, permissible 85 VAC ... 264 VAC (L-N or L-L) Frequency, nominal 50 Hz / 60 Hz Power consumption < 3 500 VA (< 7 000 VA for a time < 10 s) Connection IEC 320 / C20 Weight 29 kg / 64 lbs (case without protection cover) Dimensions (W × H × D) 468 × 394 × 233 mm (18.4 × 15.5 × 9.2 in), cover, without handles. Equipment reliability Shock IEC / EN 60068-2-27, 15 g / 11 ms, half-sinusoid, each axis Vibration IEC / EN 60068-2-6, frequency range from 10 Hz to 150 Hz, continuous acceleration 2 g (20 m /s2 / 65 ft /s2), 10 cycles per axis Environmental conditions for CPC 100 and CPC 100 accessories Operating temperature -10 °C ... +55 °C /+14 °F ... +131 °F Storage temperature -20 °C ... +70 °C / -4 °F ... +158 °F Humidity range 5 % ... 95 % relative humidity, no condensation 35 Technical data CPC 100 accessories CP TD1 – Tan-delta unit Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laboratory precision. Impedance High-voltage output S tmax f Range Resolution Typical accuracy Conditions 0 ...12 kV AC 300 mA 3 600 VA > 2 min. 15 Hz ... 400 Hz 6 digits 0 ...12 kV AC 100 mA 1 200 VA > 60 min. 15 Hz ... 400 Hz 1 kΩ ... 1, 200 MΩ V test = 300 V ... 10 kV U/f I Error < 0.5 % of reading Internal measurement of voltage output / current inputs Phase angle Range Resolution Typical accuracy Conditions Range Resolution Typical accuracy Conditions 0 ... 12 000 VAC 1V Error < 0.3 % of reading + 1 V V > 2 000 V -90° ... +90° 4 digits V test = 300 V ... 10 kV 0 ... 5 A AC 5 digits Error < 0.3 % of reading + 100 nA Ix < 8 mA Quality factor Range Resolution Typical accuracy 5 digits Error < 0.5 % of reading Ix > 8 mA 0 ... 1 000 5 digits Error < 0.5 % of reading + 0.2 % > 1 000 5 digits Error < 5 % of reading Capacitance Cp (equivalent parallel circuit) Error < 0.01 ° Inductance Range Resolution Typical accuracy Conditions Range Resolution Typical accuracy 1 pF ... 3 μF 6 digits Error < 0.05 % of reading + 0.1 pF Ix < 8 mA, V test = 300 V ... 10 kV 1 H ... 1 000 kH 6 digits Error < 0.3 % of reading 1 pF ... 3 μF 6 digits Error < 0.2 % of reading Ix > 8 mA, V test = 300 V ... 10 kV Watts / power (P, Q, S) Power factor PF / dissipation factor DF Range Resolution Typical accuracy Conditions 0 ... 10 % (capacitive) 5 digits Error < 0.1 % of reading + 0.005 % f = 45 Hz ... 70 Hz, I < 8 mA, V test = 300 V ... 10 kV 0 ... 100 % (PF) 5 digits 0 ... 10 000 % (DF) Error < 0.5 % of reading + 0.02 % Range Resolution 0 ... 3.6 kVA 5 digits 0 ... 3.6 kW/kVAr 6 digits Typical accuracy Error < 0.5 % reading + 1 mVA Error < 0.5 % reading + 1 mW / mVAr Mechanical data V test = 300 V ... 10 kV Dimensions (W × H × D) 450 × 330 × 220 mm / 17.7 × 13 × 8.7 in Weight 25 kg / 55.2 lbs CP SB1 – Switch box CP TC12 – 12 kV oil test cell The CP SB1 switch box enables fully automatic testing of three-phase power transformers. The CP TC12 oil test cell precisely determines the dielectric constant, the dissipation factor (tan delta) and the power factor of insulating liquids such as transformer oil. AC input / V1 AC output Max. 300 Vrms DC input Max. 6 ADC Cell type Transformer high and Max. 300 Vrms between all connectors low voltage connections and ground Three-electrode design with guard Test gap 11 mm / 0.43 in Supply Via serial interface from CPC 100 (+15 V) Capacitance of empty cell (air) Approx. 65 pF ± 10 % Dimensions (W × H × D) 357 × 235 × 111 mm / 14.1 × 9.2 × 4.4 in Sample volume 1.2 liters ... 2 liters / 41 ... 68 fl.oz. Weight 3.5 kg / 7.7 lbs Max. RMS test voltage 12 kV Inner dimensions (diameter × height) 172 mm × 180.8 mm / 6.8 × 7.1 in 36 Outer dimensions (W × H × D) 220 × 235.5 × 220 mm / 8.7 × 9.3 × 8.7 in Weight Approx. 9.2 kg / 20 lbs CP CU1 – Coupling unit In combination with the CPC 100 the CP CU1 is used for line parameter measurements and ground testing. Output ranges Inputs Range Current Compliance voltage at > 45 Hz 10 A 0 ... 10 A rms 500 Vrms 20 A 0 ... 20 A rms 250 Vrms 50 A 0 ... 50 A rms 100 Vrms 100 A 0 ... 100 A rms 50 Vrms Characteristic Rating V SENSE Overvoltage category CAT III (IEC 61010-1) Voltage range 0 ... 600 Vrms BOOSTER Overvoltage category CAT I Output power Voltage range 0 ... 200 Vrms Characteristic Rating Current range 0 ... 30 Arms Maximum power 5 000 VA (45 Hz ... 70 Hz), cos φ < 1.0 for 8 s at 230 VAC 5 000 VA (45 Hz ... 70 Hz), cos φ < 0.4 for 8 s at 115 VAC Frequency range 15 Hz ... 400 Hz Fuse Continuous power 0 ... 1 600 VA 30 A fast acting, automatic circuit breaker Accuracy Measuring transformers Transformer Ratio Accuracy at 50 Hz / 60 Hz VT 600 V : 30 V Class 0.1 CT 100 A : 2.5 A Class 0.1 Range Mechanical data Dimensions (W × H × D) 450 × 220 × 220 mm / 17.7 × 8.7 × 8.7 in Weight 28.5 kg / 62.78 lbs Accuracy of absolute value Accuracy of phase angle V SENSE voltage I OUT current Current range 100 A 0.05 ... 0.2 Ω 1.0 ... 0.5 % 1.5 ... 0.8° 5 ... 20 V 100 A 0.2 ... 2 Ω 0.5 ...0.3 % 0.8 ...0.5° 20 ... 50 V 100 ... 25 A 100 A 2 ... 5 Ω 0.3 % 0.5° 100 V 50 ... 20 A 50 A 5 ... 25 Ω 0.3 % 0.5° 100 ... 250 V 20 ... 10 A 20 A 25 ... 300 Ω 0.3 ... 1.0 % 0.5 ... 1.5° 250 ... 500 V 10 ... 1,5 A 10 A CP GB1 – Grounding box HGT1 – Handheld grounding tester The CP GB1 grounding box features high current surge arrestors to protect the CP CU1 and the CPC 100 from unexpected overvoltages on the line under test. The HGT1 handheld grounding tester can be combined with the CPC 100 and CP CU1 to measure step and touch voltages. Nominal ac spark-over voltage < 1 000 Vrms Impulse spark-over voltage < 2 000 Vpeak Short circuit proof with: 16 mm cylindrical or 20 mm ball studs 26.5 kA (< 100 ms) / 67 kApeak 25 mm ball studs 30 kA (< 100 ms) / 75 kApeak Torsional moment for changing arrestors > 15 Nm Dimensions (Ø × H) 200 × 190 mm / 7.9 × 7.5 in Weight 6.8 kg / 13.2 lbs (including grounding cable) 37 Voltage input Max. 25 Vrms Power supply 1 × 3.7 V lithium polymer (Li-Po) battery Dimensions (W × H × D) 90 × 180 × 45 mm / 3.5 × 7.1 × 1.8 in Weight (including battery) 0.48 kg / 1 lb Technical data CPC 100 accessories CP DB1 – Discharge box CP CR500 – Compensation reactor The CP DB1 transformer discharge box facilitates fast discharging of power transformers during the test process. The CP CR500 compensating reactor allows to test the insulation quality of generators, motors, cables and other systems with large capacitance. 6 A path Switch closed 6 A continuous Switch open The discharge process is faster by a factor of 4 compared to the CPC 100 6 Apeak Overtemperature protection: 85 ºC / 185 ºF Overvoltage protection: 150 V / 5 kA between connectors 100 A path Switch closed Switch open Inductors 2 × 40 H 2 × 80 H 1 × 40 H and 1 × 80 H Current compensation 50 Hz 2×1A 2 × 0.5 A 1 × 1 A + 1 × 0.5 A 60 Hz 2 × 0.8 A 2 × 0.4 A 1 × 0.8 A + 1 x 0.4 A Capacitance compensation 100 A continuous 50 Hz 2 × 250 nF 2 × 125 nF 1 × 250 nF + 1 × 125 nF 60 Hz 2 × 180 nF 2 × 90 nF 1 × 180 nF + 1 × 90 nF On/off times at 25 °C The discharge process is faster by a factor of 10 compared to the CPC 100 100 Apeak 2 500 Jmax Overvoltage protection: 200 V / 30 kA between connectors Mechanical data Dimensions (W × H × D) 357 × 235 × 147 mm / 14.0 × 9.2 × 5.8 in Weight 4 kg / 8.8 lbs 0.5 A on/off times: 6 min/6 min on/off times: 6 min/6 min on/off times: 6 min/6 min 1A on/off times: 2 min/6 min - on/off times: 2 min/6 min Maximum test voltage 12 kVrms (≥ 50 Hz) Dimensions (W × H × D) 455 × 275 × 220 mm / 17.9 × 10.8 × 8.7 in Weight 36 kg / 79.4 lbs CP CB2 – Current booster CPOL2 – Polarity checker The CP CB2 is an current booster for applications requiring currents up to 2000 A. The CPOL2 can check the correct polarity along the different connection points in an instrument transformer's secondary wiring. Output current up to 2 000 A Output power at 2 000 A 5 kVA Measuring range 250 μVrms ... 300 Vrms Accuracy of current at 50 Hz / 60 Hz Error < ± 0.13 % (rd) ± 0.13 % (fs) Evaluated signal form Polarity test signal with slope ratio ≥ 3:1 Phase tolerance at full scale Error < ± 0.25 % Nominal frequency 52.6 Hz Dimensions (W × H × D) 186 × 166 × 220 mm 7.3 × 6.5 × 8.7 in Power consumption Measurement active: < 100mW Standby: < 50 μW Weight 16.0 kg / 35.3 lbs Input impedance > 300 kΩ Batteries Type and number: 2 × 1,5 V Mignon LR6 AA AM4 MN1500 Dimensions (W × H × D) 180 × 55 × 35 mm / 7.1 × 2.2 × 1.4 in Weight 150 g / 0.33 lb CP RC – Compensating reactor The CP RC resonance circuit units in combination with the CPC 100 can be used for voltage withstand testing of gas-insulated switchgears (GIS). CP TR7 / CP TR8 CP CR4 /CP CR6 CP AT1 Voltage output 180 V1/ 220 V 220 V 254 V - 278 V Current output 60 A 150 A 16 A Apparent power on 13.2 kVAr secondary side 33 kVAr 4.4 kVAr Frequency 80 Hz ... 120 Hz 80 Hz ... 120 Hz 50 Hz / 60 Hz Insulation class F F F Weight 19 kg / 42 lbs 20.5 kg / 45 lbs 15.5 kg / 34 lbs Dimensions (W × H × D) 262 × 277.5 × 222 mm / 10.31 × 10.9 × 8.74 in 38 Ordering information CPC 100 Packages Package Description Ordering No. CPC 100 Basic Package Package including CPC 100 and all accessories to perform basic checks on primary assets. VE000601 CPC 100 Standard Package Package including CPC 100 and all accessories to perform VE000611 common electrical tests on instrument and power transformers. includes CPC 100 Basic Package In addition to the standard package powerful tools for substation comissioning are provided. VE000621 CPC 100 Transformer Test System Package including CPC 100, CP TD1 and all accessories to perform common electrical tests and power/dissipation factor measurements on power transformers. VE000645 CPC 100 Line Impedance Test System Package including CPC 100, CP CU1, CP GB1 and all accessories to perform impedance measurements for determination of distance protection relay settings. VE000602 CPC 100 Rotating Machines Test System Package including CPC 100, CP TD1, CP CR500 and all accessories to perform common electrical tests and power/ dissipation factor measurements on rotating machines. VE000648 CPC 100 PF/DF Test System Package including CPC 100, CP TD1 and all accessories to perform power/dissipation factor measurements on all assets. VE000640 CPC 100 Enhanced Package includes CPC 100 Standard Package CPC 100 Standard Package 39 Ordering information CPC 100 Upgrade Options Package Description Ordering No. CP TD1 Upgrade Option Upgrade option to expand your existing CPC 100 to a power/dissipation factor test system. VE000641 CP CB2 Upgrade Option Upgrade option allowing test currents of up to 2000 A in conjunction with the CPC 100. VEHZ0630 CP SB1 Upgrade Option Upgrade option to expand your existing CPC 100 standard package to a fully automated transformer test system. VEHZ0692 CP CU1 and CP GB1 Upgrade Option Upgrade option to expand your existing CPC 100 to a line impedance measurent test system. Note: CP sequencer test card has to be ordered separately (order no. VESM0635) VEHZ0671 Ground Impedance and Step & Touch Voltage Set Package to measure ground impedance and step and touch voltages of substations. Including handheld grounding tester HGT1 and accessories. VEHZ0708 CPC Sync Upgrade Option Upgrade option including the TRC1 which allows synchronizing up to three CPC in order to create a powerful source for HV applications. VEHO0648 Upgrade option including the TRC1 which allows synchronizing up to three CPC in order to create a powerful source for HV applications. VEHO0649 for existing CPC CPC Sync Upgrade Option for new CPC CPC 80 Slave unit including accessories for synchronization of CPCs. Note: Only CPC 100 can be used as master and slave unit. VE000649 CP RC1 Upgrade Option Upgrade option for high voltage testing on gas-insulated switchgear (GIS) up to 123 kV rated voltage. VEHZ0760 CP RC2 Upgrade Option Upgrade option for high voltage testing on gas-insulated switchgear (GIS) up to 145 kV rated voltage. VEHZ0770 40 CPC 100 Upgrade Options Package Description Ordering No. CPOL2 Upgrade Option Upgrade option to check polarity of a CT's or VT's secondary wiring. VESM0645 CP TC12 Upgrade Option Upgrade option for determination of power/dissipation factor and permittivity of insulaton liquids, e.g. transformer oil. It is used in conjuction with the CPC 100 and the CP TD1. VEHZ0601 CP DB1 Upgrade Option Upgrade option for faster discharging after a winding resistance measurement on a power transformer. VEHZ0695 CP CR500 Upgrade Option Upgrade option for power/dissipation factor measurements on rotating machines in conjuction with the CPC 100 and the CP TD1. VEHZ0604 PTM advanced Upgrade Option Upgrade option to operate your CPC using the guided workflow, depending on available software licences. VESM0671 PTM advanced for HGT1 Upgrade Option Upgrade option for the Ground Impedance and Step & Touch Voltage Set to use the guided PTM workflow with your HGT1. VESM0626 PTM DataSync "OnPremises" Upgrade Option Separate module for data synchronization and back-up: For up to 3 users For up to 10 users For up to 25 users Upgrade for 1 user VESM0677 VESM0678 VESM0679 VESM0680 PTM DataSync "Cloud" Upgrade Option Separate module for data synchronization and back-up: For up to 3 users For up to 10 users For up to 25 users Upgrade for 1 user VESM0681 VESM0682 VESM0683 VESM0684 41 A strong and safe connection Welcome to the team At OMICRON you can always depend on an experienced team that actively supports you and an infrastructure that you can rely on. We always listen attentively in order to understand your needs so that we can offer you the best possible solutions. We strive for lasting partnerships and ensure that you can continue to rely on your product long after you've purchased it. In order to do this, we focus on quality, the transfer of knowledge and unique customer support. Don, Wenyu and Christoph are able to tell you about the services we have available for you and why it pays to be part of the team. Don Platts Application Specialist Solutions you can rely on... ... developed with experience, passion and an innovative approach that we use to continually set groundbreaking standards in our industry sector. We invest more than 15 % of the total turnover in research and development so that we can even guarantee the reliable use of the latest technology and methods in the future. Our comprehensive product care concept also guarantees that your investment in our solutions – like free software updates – pays off in the long term. 42 Wenyu Guo OMICRON Academy We share our knowledge... … by maintaining a constant dialogue with users and experts. Some examples of this are our customer events and conferences that take place all over the world and our collaboration with numerous standardization committees. We also make our knowledge available to you in the customer section of our website in the form of application reports, specialized articles and articles in the discussion forum. With the OMICRON Academy, we also provide a wide spectrum of training possibilities and assist you with Start-up training and free webinars. Christoph Engelen Technical Support When rapid assistance is required... … our excellent level of support is always appreciated. You can reach the highlyqualified and committed technicians in our customer support department 24 hours a day, seven days a week – and it's completely free. We deal with repair services and service features in a fair and non-bureaucratic manner. We can help minimize your downtime by lending you equipment from a readily available plant at one of our service centers in your area. A comprehensive offer of services for consulting, testing and diagnostics completes our range of services. 43 OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete. Customers in more than 140 countries rely on the company’s ability to supply leadingedge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry. The following publications provide further information on the solutions described in this brochure: Diagnostic Testing CP CU1 Primary Test Manager™ (PTM) Coupling unit for line and ground testing Testing and management software for primary assets CP CU1 Brochure Solutions for Power Primary Test Manager™ (PTM) Brochure Transformers Brochure For more information, additional literature, and detailed contact information of our worldwide offices please visit our website. www.omicronenergy.com © OMICRON L2791, November 2017 Subject to change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-GB Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Modify Date : 2017:12:20 10:44:15+01:00 Create Date : 2017:12:20 10:44:15+01:00 Metadata Date : 2017:12:20 10:44:15+01:00 Format : application/pdf Document ID : uuid:62a46005-71dd-4199-a0ec-b1099fc01922 Instance ID : uuid:7a8812a4-df37-4447-b337-2af0a7f80d8a Page Layout : TwoPageRight Page Count : 44EXIF Metadata provided by EXIF.tools