Lesman It's On Fire Combustion Instrumentation Catalog B1048 Cat2008

User Manual: B1048

Open the PDF directly: View PDF PDF.
Page Count: 32

DownloadLesman It's On Fire Combustion Instrumentation Catalog B1048 Cat2008
Open PDF In BrowserView PDF
IT’S ON FIRE!
With our partners at
Honeywell, Maxon, Fireye, and
Kromschroder, we can provide
you a one-stop source for all
your combustion needs.

Lesman Chronicle

VOLUME BCS-2008 • LESMAN INSTRUMENT COMPANY

Seeing
Dollar
$ign$?

WHY GAMBLE?
...Are you willing to risk
worker safety for the
chance to keep your
boiler, furnace, thermal
oxidizer, or process
heater running?

In this day and age, who’s
NOT concerned about
saving time, energy and
money? But where do you
start? How about with
reduced fuel costs? Or
reduced downtime?
Did you know...
• Mechanical linkages don’t
always provide precise fuelair ratio control.
• You could be spending
10% to 30% more on fuel
than necessary.
• You can reduce service and
downtime by replacing
your mechanical cam and
linkage systems.

flame safeguard control
products let you maximize
process availability under
safe operating conditions.

out
For more, check nks™
Li
ro
Honeywell’s Cont air ratio
el
fu
ss
le
ge
linka
on page 10.
control system
Coming Soon!

On-Site Training
Take a look inside: From burners and controls, flame detectors, and amplifiers to valves
and switches for pressure and temperature, Lesman has the products and the factorytrained staff to help you get the right fit for a finely-tuned combustion system.
Need portable monitors for combustion efficiency? We’ve got those, too!

Lecture and hands-on sessions
taught by our factory-trained
product specialist.
Classes customized
on
to focus on your More
3!
ge
pa
specific interests.

Flame Safeguard and Burner Control Systems Catalog
See
Page

What’s Inside?
Actuators

See
Page

What’s Inside?
Pressure Controls

Honeywell Modutrol IV Low-Torque Rotary Actuator Motors........................... 13
Honeywell V4055 On-Off Gas Valve Actuator.......................................................... 14
Kromschroder IC20/IC40 Valve Actuators................................................................. 19

Burner Control Systems
Fireye BurnerLogix Integrated Burner Management System............................ 19
Fireye Flame Monitor Burner Control System......................................................... 20
Fireye MicroM Flame Safeguard Burner Control System..................................... 18
Fireye MB Industrial Multiburner Flame Safeguard System............................... 21
Honeywell 7800 Series Microprocessor-Based Burner Controls....................4–5
Honeywell ControLinks™ Linkageless Fuel Air Ratio Controls...................10–11
Honeywell RA890 Protectorelay® Electromechanical Primary Control......... 12
Kromschroder Flame Relays and Burner Control Modules.........................22–23
Maxon SMARTFIRE® Intelligent Combustion Control System........................... 15

Flame Detectors and Amplifier Modules
Fireye Flame Scanners..................................................................................................... 20
Fireye 65UV5 Integrated Flame Scanner with Internal Flame Relay............... 21
Honeywell R78 Series Flame Signal Amplifiers..........................................................6
Honeywell Flame Detectors........................................................................................8–9
Kromschroder UVS8T Ultraviolet Flame Detector................................................. 23

Industrial Burners
Maxon Industrial Burners........................................................................................16–17
© 2008 Lesman Instrument Company Bensenville IL. All Rights Reserved.

Honeywell P7810C Pressuretrol® Line Voltage Pressure Controller................ 11
Honeywell C6097 Safety Limit Switches................................................................... 12
Honeywell L404F Pressuretrol® Operating Controls............................................ 12
Kromschroder DG Pressure Switches for Gas Applications................................ 24

Valves
ASCO Safety Shutoff Solenoid Valves for Combustion Systems....................... 27
Honeywell V5055 Gas Safety Shutoff Valves............................................................ 14
Honeywell V51E Firing Rate Gas Valves..................................................................... 14
Kromschroder BV Butterfly Valves............................................................................... 25
Kromschroder Valvario® VAS Safety Shutoff Solenoid Valves............................ 26
Maxon Control Valves and Safety Shutoff Valves................................................... 15

Combustion Monitors and Gas Detectors
COSA Zircomat In-Situ Stack Gas Oxygen Analyzer.............................................. 28
Testo Combustion Analyzers from RAECO Rents! .................................................. 29
TSI CA-Calc 6213 Combustion Analyzer from RAECO Rents! ............................. 29
Portable Combustible Gas Detectors from RAECO Rents! ...........................30–31

Burner Control Accessories
Fireye MicroM Subbase Mounting Adapters........................................................... 18
Honeywell 7800 Series Burner Control Plug-In Modules..................................6–7
Honeywell Q7800 Wiring Subbases...............................................................................5
Due to contractual agreements with our manufacturers, some items in this
catalog may not be available in all geographic areas or markets. Prices are
current as of publication date, and are subject to change without notice.

rner Furnace
Typical Single Bu rd System
egua
with Flame Saf

1.
2.
3.
4.
5.
6.
7.

Manual shutoff cock
Gas pressure regulator
Low pressure interlock
Motorized gas valve manual reset
Control valve operator
High gas pressure interlock
Test cock

8.
9.
10.
11.
12.
13.
14.

Pilot gas cock
Pilot pressure regulator
Pilot solenoid valve
Gas pilot burner assembly
Solid-state ignition transformer
Flame detector
Primary control relay mounting base

15.
16.
17.
18.
19.
20.

High limit safety shutdown
Thermocouple leadwire
Thermocouple sensor
Burner valve controller
Main gas valve operator (automatic)
Vent valve (normally open)

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

IT’S ON FIRE
CATALOG 2008

3

rve You Better!
Se
to
es
Lin
t
uc
od
Pr
on
sti
bu
m
Co
Expanded
Dear Friends,
de combustion solutions.
expanded our product offering to inclu
As you can see in this catalog, we’ve
ful to bring you products that
green”, we thought it would be help
ng
“goi
ut
abo
hear
you
that
all
With
matter if you have a thermal
y and reduce energy costs. It doesn’t
can help improve burner efficienc
rove your burner efficiency
imp
ace, we’ve got products to help
furn
or
kiln
er,
heat
ess
proc
r,
boile
oxidizer,
the burner, we’ve got your soluoil. No matter how big or how small
and use less natural gas or heating
tion for energy savings.
t all of your insurance
flame safety controls to help you mee
neither is running a
and
If it’s safety your interested in, we have
,
safe
isn’t
s
flare
safe. Lighting burners with
s.
requirements and keep your workers
ence
re proper startup and shutdown sequ
s
process without the controls that ensu
ialists will make sure that your upgrade
e safety” on staff, give us a call. Our spec
or
flam
ple
peo
know
your
that
ze
folks
ardi
“the
jeop
have
rols
er
cont
If you no long
le as flame safety
ple safe. Don’t let something as simp
meet all codes and keep your peo
shut down your process.
solutions to reduce NOx and other
e teamed up with vendors that have
We’v
s?
gase
”
ouse
ip in RAECO,
enh
“gre
cing
Need to focus on redu
you covered. And with our ownersh
vative burners and sensors, we’ve got
inno
ugh
Thro
s.
tant
s.
pollu
rule
l
EPA
enta
with
environm
comply
ment stack gas emissions to help you
e upgrades
we can even help measure and docu
rol systems. So, if you’d like to do som
cont
er
burn
or
ty
safe
e
flam
nt
leme
imp
years of
you
have
help
ners
to
let us know. Our part
We even have the expertise
or expertise, just give us a call and
time
the
er
eith
have
’t
don
.
but
s,
nally
cost
to save energy
safely and professio
e, maximize your uptime, and do it
ace or boiler
experience and can minimize downtim
e’s no need for an unplanned furn
Ther
g.
acin
old controls that need repl
so give us
ple,
your
by
peo
ing
your
walk
and
you
keep
for
ldn’t
best
is
shou
You
simply don’t work. Being safe
rols
cont
old
your
use
beca
pen
hap
“relocation” that can
ng.
a call and we’ll help you start upgradi
Sincerely,

Watch our website for even
more helpful tips and product
information on flame safety
and burner control products.

Mike DeLacluyse

Combustion Systems Training
At Lesman, our goal is to make sure you get the right product, understand how it
works, make sure it’s installed properly, and get the most out of it. To help you
with that, we’ve created a set of classes to teach you what you need to know
about combustion systems, burner controls, and flame safety.
Courses are done in a lecture style with question/answer periods. Where
necessary, they include some hands on examples. Classes can be held at your plant
or in a Lesman Training Center, and can be customized to meet your needs. Here’s
a sample of what you can expect from our Lesman U course on combustion.
p Lesson 1: When is Flame Safety Required?
• Types of applications
• Basics of flame detection
• Introduction to basic burner systems and terminology
• Main functions of flame safety controls
• A fully implemented burner system
p Lesson 2: Burner Controls
• Four categories: Flame switches, primary controls, programmers,
microprocessor control systems
• Functions of flame safety systems: System checks, burner system sequencing,
supervisory functions and shutdown
p Lesson 3: Advanced Flame Safety Control Programmers
• System components
• System functions and applications
p Lesson 4: Advanced Flame Safety Concepts
• Valve proving systems
• Linkageless control systems (Honeywell ControLinks™)
• Energy savings with pulse firing
p Lesson 5: Gas Trains and Valves

Meet Dan...
Dan Weise,Lesman product specialist, instructs our customers on
process instrumentation theory,
hardware and software.
Dan’s recent courses have included Honeywell UDC controllers,
Trendview and X-Series paperless
recorders, and Siemens SIMATIC
PDM HART software. Other course
curricula include basics of instrumentation (temperature, pressure, level, and flow) and
basics of Modbus protocol.
Dan has been involved in all facets of data acquisition and
process instrumentation, from sales and commissioning to
service and product support since 1978. He’s a long-time
member of ISA, and has been with Lesman since 1988.
In his words, Dan is the guy “who reads all the manuals
nobody else reads.”In our customers’words,he’s the trainer
to call if you want to “cut to the SO WHAT of instrumentation,” so it’s easy to understand.

Call 800-953-7626 to schedule
your Lesman U combustion training!

BURNER
CONTROLS

V 10.2008

4

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Microprocessor-Based Burner Controls
Choosing the Right Honeywell 7800 Series Burner Control
Model

RM7840

RM7890

RM7895

RM7898

Control Type

Programming

On-Off Primary

On-Off Primary

On-Off Primary

Added
Function

Selectable Pre-Purge Timing,
Air Flow Check

Units Available with Valve
Proving (VPS)

Selectable Pre-Purge Timing

Selectable Pre-Purge Timing,
Shutter Drive, Programmable
Post-Purge, Valve Proving

Required
Components

Q7800 Wiring Subbase
R78 Flame Signal Amplifier
ST7800 Purge Timer Card
S7800A1142 Keyboard Display
(for VPS)

Q7800 Wiring Subbase
R78 Flame Signal Amplifier
S7800A1142 Keyboard Display
(for VPS)

Q7800 Wiring Subbase
R78 Flame Signal Amplifier
ST7800 Purge Timer Card

Q7800 Wiring Subbase
R78 Flame Signal Amplifier
ST7800 Plug-In Purge Timer
Card, S7800A1142 Keyboard
Display (for VPS)

RM7840 Programming Control Unit for Forced-Air Burners
Programming control with valve proving for automatically fired gas-, oil-, coal-, or combination
fuel single-burner applications.
•
•
•
•
•

Interrupted pilot type
Airflow check feature
Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity
Five LEDs provide sequence information. Power LED blinks fault code on Lockout.
CSA, FM, and UL approved

Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier,
ST7800A plug-in purge timer cards, S7800A1142 keyboard display module for advanced
diagnostics, and to set up valve proving

Model Selection Guide
Flame Establishing Period		
Pilot
Main
Interlocks
4 or 10 seconds
10, 15, or 30 seconds, or intermittent
Running and low-fire (LHL-LF)		
4 or 10 seconds
10 or 15 seconds
Lockout, low-fire and high-fire (LHL-LF&HF)		

Catalog
Number
RM7840G1022
RM7840L1075

Price
$1805.30
2150.57

RM7890 On-Off Primary Control Unit for Forced-Air Burners
Microprocessor-based integrated primary burner control for automatically fired
gas, oil, coal, or combination fuel single burner applications.
• Five LEDs for sequence information
• Closed loop logic test, expanded safe-start check, internal hardware status monitoring and tamper-resistant
timing and logic
• Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity
• Selectable recycle/lockout on loss of flame
• UL, CSA, FM, FCC approved
Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier, S7800A1142 keyboard display module (shown) for advanced diagnostics and to
set up valve proving

Model Selection Guide
Flame Establishing Period
Pilot
Main
4 or 10 seconds
Intermittent
4 or 10 seconds
Intermittent
4 or 10 seconds
Intermittent
4 or 10 seconds
Intermittent

Pilot		
Type
Special Features
Intermittent			
Intermittent
Shutter Drive Capability		
Intermittent
Valve Proving (VPS) Check Feature, Blinking LED Fault Annunciation		
Intermittent
Shutter Drive Capability, VPS Check, Blinking LED Fault Annunciation

Catalog
Number
RM7890A1015
RM7890B1014
RM7890A1056
RM7890B1048

Price
$482.49
506.27
435.25
432.90

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

BURNER
CONTROLS

5

RM7895 On-Off Primary Control Unit for Forced-Air Burners
Microprocessor-based integrated primary burner control for automatically
fired gas, oil, or combination fuel single burner applications.
•
•
•
•
•

On/off primary control with prepurge
Five LEDs for sequence information
Airflow switch check
Selectable relight or lockout on loss of flame
Optional local or remote annunciation of operation and fault information, remote reset capability

Required components: Q7800 universal wiring subbase, R78 series flame signal
amplifier, ST7800 plug-in purge timer card

Model Selection Guide
Flame Establishing Period
Pilot
Main
4 or 10 seconds
Intermittent
4 or 10 seconds
Intermittent
4 or 10 seconds
10 Seconds

Pilot		
Type
Airflow Check
Intermittent
No
Intermittent
Dynamic
Interrupted
Dynamic

Delayed		
Main Valve
Interlocks
No
Selectable
No
Selectable		
Yes
Selectable		

Catalog
Number
RM7895A1014
RM7895B1013
RM7895D1011

Price
$643.51
643.51
832.29

RM7898 On-Off Primary Control Unit with Valve Proving
Microprocessor-based integrated primary burner control for automatically
fired gas, oil, or combination fuel single burner applications.
•
•
•
•
•
•

On/off primary control
Programmable post purge and valve proving feature available through keyboard display module
Five LEDs for sequence information, power LED blinks fault code on safety shutdown
Airflow switch check and shutter drive output
Selectable recycle or lockout on loss of airflow or flame
Local or remote annunciation of operation and fault information

Required components: Q7800 universal wiring subbase, R78 series flame signal
amplifier, ST7800 plug-in purge timer card, S7800A1142 keyboard display module

Model Selection Guide
Flame Establishing Period
Pilot
Main
4 or 10 seconds
Intermittent or
		
10 seconds

Pilot		
Type
Special Features
Selectable
Shutter drive output, programmable post purge, valve proving

Catalog
Number
RM7898A1000

Price
$569.44

Q7800A or B Wiring Subbases for RM7800 Burner Controls
Select either the panel-mount
or burner-mount version of the
Z7800A,B 22-terminal universal
wiring subbase to accommodate your 7800 series relay
module. Both are fully compatible with all relay modules, to let you specify a wiring termination approach
that meets your application requirements.

Model Selection Guide
Catalog
Description
Number
22 Terminal Universal Wiring Subbase
Panel Mount
Q7800A1005
Burner/Wall Mount		 Q7800B1003

Price
$36.56
36.56

Learn more about Honeywell burner controls and flame safeguard products
online at www.lesman.com
Download specification datasheets, installation instructions, wiring diagrams and
more. Most products available to buy through our secure online store.

FLAME
SAFEGUARD

V 10.2008

6

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

R78 Series Flame Signal Amplifier Modules
• Flame signal strength 0.0 to 5.0 VDC
• Test jacks measure amplifier signal voltage
• Dynamic Ampli-Check™ or Self-Check rectification available, with safety shutdown on amplifier or system failure
• UL, CSA, FM approved
Solid-state flame signal amplifiers detect the presence of flame
in response to a signal from a rectifying, ultraviolet, or infrared flame detector.
Dynamic Ampli-Check™ circuitry tests flame amplifier during burner operation; 7800 series
relay module locks out on safety shutdown with amplifier failure.
Dynamic Self-Check Rectification Ampli­fier and Dynamic Self-Check Ultraviolet Amplifier
test electronic components in the flame detection system 10 to 12 times per minute. The 7800
series relay module locks out on safety shutdown with flame detection system failure.
R7849A flame detectors should be used only on burners that cycle on and off at least once
every 24 hours. Appliances with burners that remain on for 24 hours or longer should use ultra­
violet flame detection systems (C7012E/F detector and R7847C amplifier or C7076A detector
and R7886A amplifier).

Model Selection Guide
Color		
Flame Failure
Self-		
Code
Type
Response Time
Checking
Compatible Flame Sensors
Rectification-Type Flame Amplifiers, Green
Green
Rectification
3.0 Seconds
Dynamic
C7024E, F Flame Detector		
Green
Rectification 0.8 or 1.0 Second
Standard
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179		
Green
Rectification 2.0 or 3.0 Second
Standard
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179;		
				
Gas, Oil and Coal: Ultraviolet Flame Sensors C7012A, C
Green
Rectification 0.8 or 1.0 Second
Standard
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179*		
Green
Rectification 2.0 or 3.0 Second
Standard
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179*		
				
Gas, Oil, and Coal: Ultraviolet Flame Sensors C012A, C
Green
Rectification 0.8 or 1.0 Second Ampli-Check
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179		
Green
Rectification 2.0 or 3.0 Second Ampli-Check
Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179		
				
Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C
Green
Rectification 0.8 or 1.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179*		
Green
Rectification 2.0 or 3.0 Second
Dynamic
Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012E, F		
Infrared-Type Flame Signal Amplifier, Red
Red
Infrared
2.0 or 3.0 Second
Standard
Red
Infrared
2.0 or 3.0 Second Ampli-Check
Ultraviolet-Type Flame Signal Amplifier, Purple
Purple
UV
0.8 or 1.0 Second
Standard
Purple
UV
2.0 or 3.0 Second
Standard
Purple
UV
0.8 or 1.0 Second Ampli-Check
Purple
UV
2.0 or 3.0 Second Ampli-Check
Ultraviolet-Type Flame Signal Amplifier, Purple
Purple
UV
2.0 or 3.0 Second
Dynamic
Purple
UV
0.8 or 1.0 Second
Dynamic

Catalog
Number

Price

R7824C1002
R7847A1025
R7847A1033

$605.36
241.51
241.51

R7847A1074
R7847A1082

241.51
241.51

R7847B1023
R7847B1031

693.71
693.71

R7847B1064
R7847C1005

693.71
548.49

Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015		
Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015		

R7848A1008
R7848B1006

453.29
483.97

Gas, Oil: Minipeeper C7027A, C7035A, C7044		
Gas, Oil: Minipeeper C7027A, C7035A, C7044
Gas, Oil: Minipeeper C7027A, C7035A, C7044		
Gas, Oil: Minipeeper C7027A, C7035A, C7044		

R7849A1015
R7849A1023
R7849B1013
R7849B1021

241.51
241.51
377.08
377.08

Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061
Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061		

R7861A1026
R7861A1034

635.99
635.99

* Leadwire runs greater than 50 ft.

ST7800A Plug-In Purge Timer Cards

mer card
Don’t see the llti Lesman.
you need? Ca

Purge timers let you purge unburned fuels from the combustion chamber. The
plug-in cards install easily into the 7800 series relay module. They are available
in 15 timing ranges from 2 seconds to 30 minutes.
• Compatible with selected 7800 series relay modules.
• CSA, FM approved, UL recognized

Model Selection Guide
Catalog
Description
Number
2-Second Pre-Purge
ST7800A1005
7-Second Pre-Purge		 ST7800A1013
10-Second Pre-Purge		 ST7800A1021

Price
$67.88
67.88
67.88

Catalog
Description
Number
30-Second Pre-Purge
ST7800A1039
60-Second Pre-Purge		 ST7800A1054
1.5-Minute Pre-Purge		 ST7800A1062

Price
$67.88
67.88
67.88

Catalog
Description
Number
2.5-Minute Pre-Purge
ST7800A1070
4-Minute Pre-Purge		 ST7800A1088
6-Minute Pre-Purge		 ST7800A1096

Price
$67.88
67.88
67.88

Lesman Instrument Company

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

www.lesman.com
sales@lesman.com

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

FLAME
SAFEGUARD

7

Burner Control Plug-In Accessory Modules
S7800A1142 Universal Keyboard Display Module
Provides current status of burner sequence, timing, hold, and lockout information plus
selective or preemptive messages. Required for programming Valve Proving and Post
Purge features on 7800 series relay modules.
• First-out annunciation and system diagnostics provided in 2-row by
20-column display
• Provides burner control data, remote reset, and report generation
• Local or remote operation, fault information
Model Selection Guide
• UL listed, CSA certified, FM approved, and FCC
rated
Description
Universal Keyboard Display

Catalog
Number
Price
S7800A1142 $485.61

S7810A1009
Data ControlBus Module

S7820A1007
Remote Reset Module

Lets you connect a remote reset switch,
a remote keyboard display module, or
communicate to a personal computer.

Links a remote reset switch (push-button) that
allows the 7800 series burner control to be reset
from a remote location.

• Installs directly on front of 7800 relay modules
• Communications interface, remote reset
• Use with remote mounted keyboard display

• Installs directly on front of 7800 relay module
• Allows reset of 7800 series relay module by a remote reset
push-button up to 1000 feet away

Model Selection Guide

Model Selection Guide

Description
Remote Mounting of Keyboard Display Module
PC Interface, and Remote Reset Function

Catalog
Number
S7810A1009

Price
$206.64

Description
Remote Module for Resetting 7800 Series
Relay Module

Catalog
Number
S7820A1007

Price
$228.75

S7830A1005 First-Out Expanded Annunciator Panel
Monitors the status of a series string of limit, control, and interlock contacts. It enhances fault
and status messages of the 7800 series burner control.
• 26 LEDs — 22 LEDs to annunciate limits and interlocks, 4 LEDs to annunciate
power, current status, first-out status, and system lockout
• Enhances keyboard display module sequence hold Model Selection Guide
and lockout messages
Catalog
• Connects to 7800 series relay module via RS485
Description
Number
Price
• UL listed, CSA, FM approved
First-Out Expanded Annunciator S7830A1005 $935.07
Connector for Keyboard Display

203541

45.30

Hey Lesman... Where’s My Stuff?
well
Buy your Honey
and
burner controls
ucts
od
pr
d
flame safeguar
an
r
fo
at Lesman.com
s!
ng
vi
instant 15% sa

Want to know when your Lesman order will arrive? Use the Order
Status checker, right on the Lesman.com homepage!
• Enter your PO number and 5-digit zip code,
and click the “Check Status” button.
We’ll show your order details and a clickable
tracking link at UPS or FedEx. If the order
hasn’t shipped, it’ll give you the expected
ship date.

FLAME
DETECTORS

V 10.2008

8

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Flame Detectors

Model

C7008,
C7009

Q340A

C7012
Purple Peeper®

C7027
Minipeeper®

C7035
Minipeeper®

C7061
Purple Peeper®

C7076

Detector
Type

Flame Rod

Thermocouple

Rectification
Ultraviolet

Ultraviolet

Ultraviolet

Ultraviolet

Ultraviolet

Burner
Type

Gas-Fired

Gas-Fired

Coal, Gas, or OilFired

Coal, Gas, or OilFired

Coal, Gas, or OilFired

Gas or Oil-Fired

Gas or Oil-Fired

Pilot
Type

Intermittent or
Standing

Intermittent or
Standing

Intermittent or
Interrupted

Intermittent or
Interrupted

Intermittent or
Interrupted

Intermittent or
Interrupted

Intermittent or
Interrupted

Unique
Feature

100% Fail-Safe
Operation

Low Cost Units
for Process
Applications

Dynamic
Self-Check,
Shutter

1/2” Sight Pipe
Mount

1” Sight Pipe
Mount

Dynamic
Self-Check

Dynamic
Self-Check,
Adjustable
Sensitivity

Flame
Amplifier

R7247A,B,
R7847A, B,
R7257, R7289

Typically
Connected
via UDC

R7247C, R7847C,
R7747C

R7249A,B,
R7849A, B,
R7749B, R7259,
R7290

R7249A,B
R7849A,B
R7749B, R7259,
R7290

R7861

R7476A1015,
R7886A1001

C7008, C7009
Rectification Flame Rods
Kantal A-1 flame rod with sparkplug-type rod holder,
threaded base, and snap-on cover.
100% fail-safe flame detection. For use with gas-fired systems and
intermittent pilots only. Use with Honeywell flame safeguard controls
that require rectification-type flame detectors. Can be used with or
without cover and cut to desired length. Includes flame rod holder
and Rajah electrical connector.
Approvals: UL, CSA, FM.

Model Selection Guide
Flame Rod Holder Dimensions
Length
Length Diameter
12”
3-3/4”
7/8”
24”
3-3/4”
7/8”
4”
2-3/8”
3/8”
12”
2-3/8”
3/8”

Electrical
Connection
1/4” NPT Male		
1/4” NPT Male		
1/8” NPT Male		
1/8” NPT Male		

Catalog
Number
C7008A1174
C7008A1182
C7009A1009
C7009A1025

Price
$166.01
246.46
103.84
135.98

Q340 Thermocouples for Gas-Fired Pilot Flame Detection
Premium long-life, durable 30mv thermocouples generate a thermoelectric current that
senses a pilot flame on gas-fired heating systems.
For easy installation, the Q340A comes with a push-in clip, split nut, and an adapter assembly, plus a 11/32 male
connector nut for Pilotstat® safety control power units.
Model Selection Guide
Output: Normal: 26 to 32 mV; Lowest Acceptable: 18 mV; Turndown: 2 mV
Temperature Rating: 1400°F at hot junction, 780°F at cold junction
Replacement for: Robertshaw 1980, T45, T46, White Rogers HO series, Penn-Baso K15, K16,
K19, 88D, ITT-General 2500 and 2600 series, and Jade TK5

Catalog
Lead Length
Number
36” (914mm)		 Q340A1090
48” (1219mm)		 Q340A1108

C7076 UV Detector with Adjustable Sensitivity
Dual adjustable sensitivity with 400:1 dynamic range, for
use with intermittent or interrupted pilots on gas- or oil-fired
burners. Compatible with R7476A and R7886A dynamic selfcheck UV flame amplifiers. Closed-loop self-checking circuit
ensures integrity of both amplifier and flame detector.

Price
10.72
11.92

an.com
Visit www.lesm
els.
od
m
r
la
for popu
our
h
ug
ro
th
Buy online
ore!
secure online st

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

FLAME
DETECTORS

Available soon! UV/IR flame detectors from
IRIS Systems. Call Lesman for details.

C7012 Purple Peeper® Solid-State UV Flame Detectors
Solid-state UV flame detector with dynamic self-check, for coal-, gas-, or oil-fired burners. Can
be used with intermittent or interrupted pilots. Compatible with R7247C, R7847C, and R7747C
UV flame amplifiers on Honeywell RM7800 series relay modules.
Mounts horizontally, vertically, or at any angle in between.
Provides quick electrical hookup with threaded conduit fitting
and color-coded leadwires. Reduces nuisance shutdowns by
wiring two in parallel.
Mounting: Mounting flange with NPT internal threads for
attaching to sight pipe
Approvals: UL, CSA, FM.

Model Selection Guide
Catalog
Description
Number
Price
Dynamic Self-Checking Ultraviolet Detector
120 VAC, 3/4” NPT
C7012E1104
$3161.29
120 VAC, 1” NPT		 C7012E1112
3161.29

C7027 Minipeeper® Ultraviolet Flame Detectors
Compact UV flame detectors for use on coal-, gas-, oil-fired or combination burners. Can be
used with either intermittent or interrupted pilots. Compatible with R7248A/B, R7849A/B,
R7749B, R7259, and R7290 solid-state UV flame amplifiers on Honeywell RM7800 series relay
modules and controls.
Model Selection Guide
Compact size allows for blast-tube mounting. Seals
against pressures up to 5 psi when correctly installed.
Wire in parallel for difficult sighting applications.
Mounting: 1/2” sight pipe with integral collar or 1/2”
NPT threaded spud connector.
Dimensions: 1-1/8” diameter (with mounting nut),
3-7/8” length, 8-foot lead.
Electrical Connections: Two NEC Class 1 leadwires
Approvals: UL, CSA, FM.

Ambient
Sight Pipe
Catalog
Temp. Range
Mounting
Number
Price
-40° to 215°F
Integral nut		 C7027A1031
$166.75
-40° to 215°F
Integral nut*
C7027A1072
166.75
0° to 215°F
Integral nut
C7027A1023
150.41
0° to 215°F
Integral nut*
C7027A1049
150.41
0° to 215°F
Integral nut**		 C7027A1080
186.95
* 1/2” NPT threaded spud connector
** Includes 136733 heat block and 390427B bushing

C7035 Minipeeper® Ultraviolet Flame Detectors
Compact ultraviolet flame detectors with field-replaceable UV sensing tubes. For use on coal-,
gas-, oil-fired or combination burners. Can be used with either intermittent or interrupted
pilots. Compatible with R7248A/B, R7849A/B, R7749B, R7259, and R7290 solid-state UV flame
amplifiers on Honeywell RM7800 series relay modules and controls.

C7035

Shield protects sensing tube. Seals against pressures up to 5 psi when correctly installed. Can be wired in
parallel for difficult sighting applications.
Mounting: 1” sight pipe with integral collar
Dimensions: 1-1/2” diam. (with collar), 4-1/8”
length, 72” leads
Approvals: UL, CSA, FM.

Model Selection Guide

Catalog
Description
Number
0° to 215°F temperature range, 6’ lead		 C7035A1023
Replacement UV sensing tube for C7035
129464M

129464M
Price
$330.90
301.68

C7061 Purple Peeper® Solid-State UV Flame Detectors
Ultraviolet flame detector with dynamic self-check for gas-, or oil-fired burners. Can be used
with intermittent or interrupted pilots. Compatible with R7861
dynamic self-check UV flame amplifiers on Honeywell RM7800
series relay modules.
Model Selection Guide
Mounts horizontally, vertically, or at any angle in between.
Reduces nuisance shutdowns by wiring two in parallel. Fieldreplaceable UV sensing tube and quartz viewing window.
Mounting: Mounting flange with 3/4” NPT internal threads
Dimensions: 5-1/4” diam. (with flange), 7-7/32” long, 96” leads
Approvals: UL, CSA, FM.

Catalog
Description
Number
120 VAC, 3/4” NPT
C7061A1012
120 VAC, 3/4” NPT*		 C7061A1038
UV Sensing Tube		 129464N
* With Brad Harrison 41310 connector

Price
$1377.66
1398.48
335.68

129464N

9

FUEL AIR RATIO
CONTROL

V 10.2008

10

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

ControLinks™ Fuel Air Ratio Control System
Honeywell ControLinks™ fuel air ratio control system helps you realize energy savings, increased turndown, reduced
emissions, and system reliability in an easy-to-install, powerful, and cost-effective package.
Features
• Stand-alone parallel positioning control system
designed for easy retrofit
• Dynamic safety checks: failsafe potentiometer
check, anti-swap of actuators, and curve verification algorithms, relay test for limit control input/
output (LCI-LCO) contact set
• Integrated shock protection algorithms: Water or
stack temperature low fire hold, flue gas recirculation (FGR) hold, FGR and low-fire hold
• Controller LEDs: Power, alarm, motor 1, 2, 3, 4 for
status, and fault code annunciation (60 possible)
• Two independent fuel profiles with or without FGR
• Programmable positioning for non-selected fuel
actuator, standby, purge, light-off, or minimum/
maximum modulation
• Up to four universal parallel positioning actuators:
Combustion air, fuel 1, fuel 2, FGR/flexible usage
• Fourth channel actuator flexible usage: FR, secondary air control, secondary modulating fuel valve
• Auto/manual firing rate input
• Seven to 24 points per profile curve with quick
setup feature, providing minimum three-point
profile curve
• Actuator CW/CCW switches for manually driving
hub —useful for installation and service
• Actuator LED annunciation for unconfigured, configured, on-line, or faulty actuator states

Typical boiler application with Honeywell ControLinks™
fuel ratio control system installed.
Honeywell ControLinks™ replaces the traditional single point modulation of a
mechanical cam-and-linkage assembly that controls the relationship between fuel,
airflow, and flue gas recirculation on a power burner. The linkageless fuel air ratio
control provides more accuracy and efficiency in actuator positioning and burner
firing, reducing your service requirements and downtime. It can be installed as part of
a retrofit or a new burner application —anywhere increased efficiency is desired.
Up to four independently controlled universal parallel positioning actuators
(UPPAs) are managed by the ControLinks controller, which responds to load and
firing rate demands.
ControLinks can be used on single or combination fuel single burner applications,
including power burners, boilers, process furnaces, ovens, smelting, kilns, paint drying
booths, VOC burn-off, ceramics, make-up air heaters, or any full modulating burner.

R7999A ControLinks™ Fuel Air Controller
Uses the latest microprocessor technology to simultaneously control up to four actuators.
Use with ML7999 actuators to replace mechanical cam-and-linkage assembly controlling
the relationship between fuel, airflow, and flue gas recirculation (FGR) on a power burner.
Fast burner setup vial PC or laptop. Two independent fuel profiles with or without FGR. Programmable
behaviors of all actuators during purge and standby. Programmable behavior of non-selected fuel actuator.
Independent light off and minimum modulation positions. Auto/manual input and manual mode firing-rate
input. Multipurpose communications port.
ZM7999A ControLinks™ configuration software tool lets you create burner modulation curves (profiles)
for your burners, for safe and efficient operation at all points along the curve. Wizards step you through the
commissioning process. Save files on your PC to use over again.
Complete System Requires: R7999 controller, Q7999 wiring subbase, ML7999 positioning actuator,
and ZM7999 configuration software.

Model Selection Guide
Catalog
Description
Number
Fuel air ratio controller, 100-120 VAC, 50/60 Hz		 R7999A1005
Field wiring terminal subbase for R7999A controller. Panel mount, NEMA 1 enclosure		 Q7999A1006
ControLinks™ Windows-based configuration software for R7999A controllers		 ZM7999A1006

Price
$774.90
98.53
365.93

line at
Learn more on.c
om!
an
m
es
www.l

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

FUEL AIR RATIO
CONTROL

11

ML7999 Universal Parallel-Positioning Actuators
ControLinks™ actuators control the position of primary and secondary fuel valves,
combustion air damper, and flue gas return dampers. UL, CSA, CE approved.
Vibration: 0.0 to 0.5g continuous
Environmental Conditions: Ambient Temperature: -40° to 140°F; Operating Temperature: -40° to 150°F; Operating Humidity: 5% to 95% RH, non-condensing

Model Selection Guide

Call for adapter assemblies for
connecting to shaft sizes other
than 1/2”.

Catalog
Actuator Description and Function
Number
Pulse-width modulating control of combustion air dampers, butterfly gas valves, oil		 ML7999A2001
modulation valves, and flue gas recirculation systems. Includes precise feedback
potentiometer and integral power supply. Parallel-positioning actuator.
Provides 4-20 mA control input to control combustion air dampers and modulation		 ML7999B1002
valves. Includes precision drive shaft control and integral power supply capable of
direct line voltage connection. Direct coupled actuator.

Price
$272.80

540.84

S7999B ControLinks™ Configuration Display
Monitor up to 99 burner systems connected via Modbus. Each burner control,
fuel/air ratio control, expanded annunciator or other Modbus devices present
on the burner system can be viewed individually to determine its status.
Display: Color 3.5” x 4.6” touchscreen interface with screen saver, contrast and volume controls
Communications: Two RS485 Modbus ports for monitoring up to 99 unique controls
Function: Allows setup and monitoring of R7999 ControLinks controller, programmable
expanded annunciator terminal remaining, and R7999 EEPROM backup and restore

Model Selection Guide
Catalog
Description
Number
Touchscreen display for ControLinks™ system. 12 VDC input power		 S7999B1000

Price
$1193.07

P7810C Pressuretrol® Controller
Line voltage pressure controller that eliminates the need for a controller and transmitter.
One unit does on/off control, high limit and 4-20 mA modulation.
Accuracy: ±4.0% full scale output over operating temperature (32° to 140°F)

Model Selection Guide
Description
Solid State Pressuretrol® Controller with On/Off Control, Limit Control,
0–15 PSI		
and 4-20 mA Modulation. FM, CSA, UL Approvals.
0–150 PSI		
LED Indicators for Power, Call for Heat Function, and Lockout Status
0–300 PSI		
Siphon Loop with 1/4” NPT Threads for P7810C			

ControLinks™
Accessories

Looking for a ion
st
portable combu
?
er
analyz
See page 29.
lable
Handhelds avai nt!
re
or
le
sa
for

Catalog
Number
P7810C1000
P7810C1018
P7810C1026
209731A

Price
$524.81
583.72
651.85
32.61

Catalog
Number
201391
32002935-001
32003168-001
32003168-002
32003168-003
32003396-001
32003396-002
32002515-001

Price
$3.23
18.56
44.22
50.07
50.07
43.48
47.34
9.53

Model Selection Guide
Description
ML7999 actuator shaft adapter for and 3/8” round or square valve shaft		
ML7999 actuator weatherproofing kit (1 corner stop, 2 gaskets)		
ML7999 actuator 3/4” shaft adapter assembly		
ML7999 actuator 5/8” shaft adapter assembly		
ML7999 actuator 9/16 shaft adapter assembly		
V51E mounting plate for 1.5” and 2” valves		
V51E mounting plate for 2.5” 3”, and 4” valves		
R7999 3-pin electrical connector		

BURNER
CONTROLS

V 10.2008

12

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Mechanical Burner Controls and Safety Switches
C6097 Safety Limit Switches
Limit switches for positive or differential pressure systems to sense natural gas, liquid
propane gas, or air. Removable clear protects scaleplate and adjusting knob.
Temperature Range: -40° to 140°F
Switch Ratings: 3.0 AFL, 18.0 ALR, 5.0 Amp resistive. Can be wired to turn on alarms.

Model Selection Guide
Operating
Pressure Differential at
Switch		
Catalog
Range
Min. Setpoint Max. Setpoint
Operation
Mounting
Number
Diaphragm-Actuated Safety Limit Switch, Brake on Pressure Fall, 1/8” NPT Internal Threaded Connection
0.4” to 5” WC
0.6” WC
0.25” WC
Manual Reset
1/4” NPT		 C6097A1095
3” to 21” WC
—
—
Auto Recycle
1/4” NPT
C6097A1053
Diaphragm-Actuated Safety Limit Switch, Break on Pressure Rise, 1/8” NPT Internal Threaded Connection
12” to 60 “ WC
10” WC
12” WC
Manual Reset
1/4” NPT		 C6097B1002
1.5 to 7 PSI
1.1” WC
1.4” WC
Manual Reset
1/4” NPT
C6097B1051

Price
$117.40
96.26
124.96
136.22

L404F Pressuretrol® Controllers
Operating control with automatic limit protection for pressure systems. Use with steam, air,
noncombustible gases, or fluids non-corrosive to pressure sensing element
Switching Action: SPDT snap-action switch to open or close a circuit on pressure rise
Connections: Pipe (main or high pressure): 1/4” NPT internal thread; Electrical: Screw terminals

Model Selection Guide
Operating
Range
2 to 15 PSI
5 to 50 PSI
10 to 150 PSI

Sustained
Pressure
25 PSI max.
85 PSI max.
225 PSI max.

Adjustable
Differential
2 to 6 PSI
6 to 14 PSI
10 to 22 PSI

Sensor
Element
Stainless Steel Diaphragm
Stainless Steel Diaphragm
Stainless Steel Diaphragm

Unit
Includes
Siphon Loop		
Ground Screw		
—		

Catalog
Number
L404F1060
L404F1375
L404F1102

Price
$172.29
175.01
192.05

RA890 Protectorelay®
Electromechanical Primary Control
Non-programming primary control provides flame safeguard
protection for industrial and commercial single or dual fuel
burners. With SPDT alarm contacts.
Use with flame rods, rectifying photocells and C7012A,C Purple
Peeper ultraviolet flame detectors. Recycles once after failure to reestablish pilot. No start if failure occurs in flame detector circuit.
Power Rating: 50 Hz: 8.5w, 17VA max.; 60 Hz: 7w, 13 VA max.
Ambient Temperature: -20º to 105°F
Approvals: CSA, FM, UL

Model Selection Guide
Safety Switch Flame Failure
Description
Timing
Response*
Rectification-Type
15 Seconds
3.0 Seconds
Ultraviolet-Type
15 Seconds
3.0 Seconds
Q270A Protectorelay® Mounting Subbase 			

Catalog
Number
RA890F1288
RA890G1260
Q270A1024

Price
Each
$1385.97
1385.94
116.04

Compatible flame detectors on pages 8–9.

S8610U3009 Intermittent Pilot Ignition Control
Provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot
ignition systems used on natural or LP gas-fired furnaces, boilers, and heating applications.
Model Selection Guide
Electrical Rating: 24 V, 60 Hz; Current Draw: 1A
pilot valve, 2A main valve; Contact Rating: 0.2A
Field Replacement: For most Honeywell,
Robertshaw, Johnson, UTEC (HCS)
intermittent pilot ignition modules

Description
Intermittent pilot control. 15- or
90-sec trial for ignition, 0- or
30-sec configurable pre-purge

Catalog
Number

Price

S8610U3009 $164.37

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

ACTUATOR
CONTROLS

13

Low-Torque Rotary Actuator Motors
Modutrol IV
Low torque, light duty, rotary action Modutrol IV motor is designed for accurate positioning
of dampers and valves in industrial ovens, furnaces, and process heaters.
Torque Rating: 25 to 300 Lb-In
Timing: 15 to 240 seconds
Stroke: Fixed or adjustable, 90° and 160° dual on some models
Limit Switches: Two end-of-travel limit switches standard
Approvals: CSA, UL

More models available online. Visit www.lesman.com/get/modutrol.php for series
specifications, model selection, and part number cross references.
Model Selection Guide

* Field-addable auxiliary switches

Stroke Timing
Torque
Auxiliary		
Functional Replacement
Catalog
90°
160°
Rating
Switches
Product Includes
for These Obsolete Models
Number
Proportional-Reversing Motors, 135 Ohm Input Signal, 90° to 160° Field-Adjustable Stroke (Unless otherwise specified)
15 sec 30 sec 75 Lb-in
0				 M9184D1005
15 sec 30 sec 75 Lb-in
1
Tapped Shaft
M9484D1002, D1036, and E1116		 M9484E1009
30 sec 60 sec 35 Lb-in
0
Adjustable Zero/ Span, Transformer
M8161A1024 and A1032, 		 M9164A1005
						
M9161A1008, M9164A1021 and A1054
30 sec 60 sec 35 Lb-in
0*		
M9164A1120, A1062, A1047, and A1096
M9164D1009
30 sec 60 sec 60 Lb-in
0*
24 VAC, Spring Return
M7285A1052, M7282A1006,		 M9185D1004
						
M9175D1014, D1006, and D1014
30 sec 60 sec 60 Lb-in
1				 M9185E1019
30 sec 60 sec 150 Lb-in
0		
M9484D1028, D1044, and D1051		 M9484D1010
30 sec 60 sec 150 Lb-in
0*		
M9184A1012, A1035, B1009, B1017, B1025,		 M9184D1021
						
M9184D1013, D1047, and D4009
30 sec 60 sec 150 Lb-in
1		
M9484E1090 and E4003		 M9484E1017
30 sec 60 sec 150 Lb-in
1
Motor Crank Arm,
M9484E1025, E1041, E1058, E1066,		 M9484E1033
					
Ships in 90° Position
M9484E1074, and E1082
30 sec 60 sec 150 Lb-in
2
Ships in 90° Position			 M9484F1007
30 sec 60 sec 150 Lb-in
2
Tapped Shaft, Ships in 90° Position			 M9484F1031
30 sec 60 sec 150 Lb-in
2		
M9184F1000 and F1018		 M9184F1034
30 sec
—
35 Lb-in
2				 M9184C1031
—
60 sec 60 Lb-in
2
24 VAC, Spring Return			 M9185C1006
—
60 sec 150 Lb-in
0		
M9181A1012, M9184A1001		 M9184A1019
Proportional-Reversing Motors, 120 VAC Power, Modulating 4-20 mA Input, Adjustable Zero and Span. Transformer and Screw Terminal Adapter Included
15 sec 30 sec 75 Lb-in
0				 M7284A1038
30 sec 60 sec 150 Lb-in
0		
M281A1007, M7284A1046
M7284A1004
30 sec 60 sec 150 Lb-in
0		
M7284A1020		 M7284A1012
30 sec 60 sec 150 Lb-in
2		
M7284C1018, M7284C1026
M7284C1000
30 sec 60 sec 150 Lb-in
2		
M7284Q1017
M7284Q1009
60 sec 120 sec 300 Lb-in
2				 M7294Q1007
Motors with Switched SPDT or Floating Output, 120 VAC Power, SPDT Input, 3-Wire, Line Voltage, or Position Proportional Controller
—
30 sec 75 Lb-in
0				 M6184A1023
30 sec
—
150 Lb-in
0		
M6284A1014, A1002, A1048, A1071, and 1063		 M6284A1055
Motors with Switched SPDT or Floating Output, 24 VAC Power, 3-Wire, SPDT or Voltage Input
15 sec 30 sec 75 Lb-in
0
Low Voltage			 M6184D1001
30 sec 60 sec 150 Lb-in
0*
Low Voltage
M6181A1018, D1004, F1009, F1017, 		 M6184D1035
						
M6161A1004, M6184A1007 and B1021
30 sec 60 sec 150 Lb-in
2
Line Voltage			 M6184F1014
Stroke Stroke Torque
Auxiliary		
Functional Replacement
Timing (Deg)
Rating
Switches
Product Includes
for These Obsolete Models
Two-Position Spring Return Motors, SPST, 2-Wire, Voltage Inputs
30 sec
75°
20 Lb-in
1
120 VAC Power
M436A1041 A1082, A1090, A1165, and A1181		
60 sec
160°
60 Lb-in
0
120 VAC Power			
60 sec
160°
60 Lb-in
1
120 VAC Power
M4182B1002		
30 sec
90°
60 Lb-in
1
120/208/240 VAC
M4185B1017
20 sec
45°
30 Oz-In
0				
30/60 90/160 60 Lb-in
0*
24 VAC
M8185B1000 and B1034 (w/ 220736A)		

Catalog
Number
M436A1116
M4185A1001
M4185B1009
M4185B1058
M847A1072
M8185D1006

Price
$806.09
965.43
682.92
608.10
905.25
1013.40
822.55
836.50
965.43
954.42
1014.01
1024.93
1008.54
1008.54
1094.20
806.09
984.96
940.89
940.89
1103.17
1103.17
1106.72
606.46
733.15
554.23
544.29
714.91

Price
$350.76
554.32
587.40
610.07
123.66
456.87

VALVES AND
ACTUATORS

V 10.2008

14

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Valves and Actuators
V4055 On-Off Gas Valve Actuator
Use with Honeywell V5055 gas valves where smooth light off is important to control gas
supply to industrial burners.
Model Selection Guide
One second maximum closing time. Continuous display of valve position with a red
(open) or yellow (closed) indicator. Provides
final safety shutoff service when used with
V5055 valves.
Temperature Range: -40° to 150°F
Operating Pressure: 5 psi maximum
Electrical Rating: 120 VAC, 60 Hz
Auxiliary Switch Contact Ratings: 9.8 AFL,
55.8 ALR, 1/2 hp;
Proof of Closure Switch Contact Ratings
(V4055D): 4.9 AFL, 29.4 ALR, 1/2 hp; 9.8 AFL,
58.8 ALR, 1/2 hp

Timing
Internal
Damper
Catalog
(Open) Auxiliary Switch
Shaft
Number
Price
On-Off Actuator, Use with V5055/V5097A,B Valve Bodies
13 sec
Yes (90° Stroke)
No		 V4055A1296 $559.16
No
Yes		 V4055A1098
499.13
13 sec
13 sec
No
No		 V4055A1031
499.13
26 sec
No
Yes		 V4055A1064
462.11
26 sec
No
No		 V4055A1007
462.11
26 sec
No
No		 V4055A1312* 976.96
On-Off Actuator with Proof of Closure Switch, Use with V5055C/
V5097C Valve Bodies
Yes
No
13 sec
V4055D1035
600.71
13 sec
No
Yes		 V4055D1019
540.65
13 sec
No
No		 V4055D1043
540.65
26 sec
No
Yes		 V4055D1001
505.95
* NEMA 4 Enclosure

V5055 Industrial Gas Safety Shutoff Valve
Safety shutoff valves used with V4055 fluid power actuators to control natural or LP gas
flow to commercial and industrial burners. Mounts directly in gas supply line.
Temperature Range: -40°F to 150°F
Includes: 1/4”–18 NPT upstream and downstream taps and plugs
Proof of Closure: V5055C valves have double seal and are used with V4055D and V4055E actuators to provide
proof-of-closure switch and valve seal over-travel interlock
Approvals: FM, CSA, and UL

Model Selection Guide
Pipe		
Max Operating		
Catalog
Size
Capacity
Differential*
Functions
Number
Safety shutoff valves for use with V4055 valve actuators
1.5” NPT 1717 cf/Hr – 48.6 m3/Hr
5 PSI max
On/off safety shutoff		 V5055A1020
2” NPT 3620 cf/Hr – 102.5 m3/Hr
5 PSI max
On/off safety shutoff		 V5055C1000
				
with double seal
2.5” NPT 4250 cf/Hr – 120 m3/Hr
5 PSI max
On/off safety shutoff		 V5055C1018
				
with double seal
3” NPT
4250 cf/Hr – 148 m3/Hr
5 PSI max
On/off safety shutoff		 V5055A1053

Price
$301.74
731.15
861.65
674.84

* When used with V4055A or D models. 15 PSI when used with V4055B, E, F, or G models.

V51E Butterfly Firing Rate Gas Valve

Provides modulating control of natural, manufactured, LP gases or air.
Use in commercial and industrial instal- Model Selection Guide
lations where large amounts of gas must
be closely controlled. Do not use as a safety
shutoff valve. Use with mod motor and
Q100 linkage. Includes strain release.

Looking for a
mod motor?
See page 13.

Temperature Range: 32° to 140°F
Pressure: Rating: 5 psi max.; Inlet/outlet
pressure tapping: Two downstream 1/4”
NPT taps
Material: Aluminum body
Approvals: UL

Pipe		
Size
Capacity
1.5”
4200 cf/Hr – 118.9 m3/Hr		
2”
9210 cf/Hr – 260.7 m3/Hr		
2.5”
8390 cf/Hr – 199.8 m3/Hr		
3”
14640 cf/Hr – 414.5 m3/Hr		
Bracket for 2” valve/Modutrol motor		
Bracket for 2.5” valve/Modutrol motor		
Strain release assembly		
Stop screws for stop bracket (2 reqd.)		
Linkage kit V51 to M941 Modutrol		

Catalog
Number
Price
V51E1000
$396.95
V51E1018
448.72
V51E1034
474.85
V51E1059
500.35
127413
169.18
127415
203.18
49085B
214.28
80897BC/0021
2.93
Q100B1006
99.81

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

COMBUSTION
CONTROLS

15

MAXON Combustion Control Systems

SMARTFIRE® Intelligent Combustion Control System
• Precise electronic control of air and fuel flow to the burner to maximize efficiency and minimize emissions simultaneously
• Maintains emissions or fuel efficiency over the entire operating range
of the burner, not just at one burner setpoint
• Automatically compensates for changes in combustion or process
conditions with full cross-limited ratio control, maximizing burner
performance and ensuring a highly repeatable heat source
• Integrates easily with all burner management systems, reducing
engineering costs in retrofit applications

• Advanced diagnostics and troubleshooting provide real-time information about combustion and process system performance
• Remote monitoring gateway option reduces process downtime by
providing immediate off-site technical support over a phone line
• Redundant system safety checks built into intelligent components
significantly reduces the risks associated with combustion system
commissioning and maintenance neglect
• FM and CSA approved,and meets requirements
of European EMC and low-voltage directives

Safety Shutoff Valves
• Cast iron, carbon steel, low-temp carbon steel,
and stainless steel bodies with internal trim options for general purpose or corrosive gases
• Unique bonnet design eliminates packing
adjustments, reducing maintenance and
minimizing drag on closing
• Oxygen compatibility available
• Meet Fluid Control Institute 70-2 control valve
standard for Class VI seat leakage; Full assessment to IEC 61508 as SIL-3 capable

Series 5000 Electromechanical Valves
• Electrically actuated valves
with powerful closing spring,
provides closure in <1 second
for reliable operation
• 3/4” to 6” line sizes, pressures
to 125 psig
• Field-rotatable top assemblies
in 90° increments to fit your application
• Actuators available with manual reset or
automatic reset operators
• Ambient, gas temperatures: -20° to 140°F
• Available normally closed or normally open
• FM, CSA, UL, and CE approved; Available for
non-incendive Class I, Div 2 areas

Series 8000 Air-Actuated Valves
• Pneumatically actuated
valves with powerful
closing spring for reliable
operation
• 3/4” to 6” line sizes, pressures
to 255 psig
• Compact design with integral solenoid, quick exhaust
and position switches that
protects components, simplifies piping, and minimizes space needs
• Temperature ranges: Ambient: -40° to 140°F;
Gas: -40° to 212°F
• FM, CSA, and CE approved safety shutoff and
vent valves; Available in intrinsically safe and
non-incendive constructions for hazardous
location use
• NACE-compliant trims available

information
Look for more
stion control
on Maxon combu and valve
s,
systems, burner Lesman.com
at
e
lin
products on

MICRO-RATIO® Flow Control Valves
These assemblies are used for air, gas,
and oil proportioning control. The multiple
screw cam assembly provides mechanical
adjustment capabilities to the air/fuel ratio
at each valve position throughout the entire
capacity range of your burner system.
Throttling range is fully adjustable and
designed to operate over the wide turndown
capabilities of Maxon’s burner systems.
Stand-by fuel requirements are simplified
by using tandem-linked “air-gas-oil” valves
to provide single point control for multiple
fuel or multiple zone systems.
A complete system using Maxon flow
control valves will typically include a burner,
gas and/or oil pipe trains,mixing equipment,
pressure blower, and a control panel.

INDUSTRIAL
BURNERS

V 10.2008

16

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

www.lesman.com
sales@lesman.com

Make-Up Air (Food or Spray Dryers, Food Processing)

√

Oxidizers
Paper Mill Dryers
Pre-Heated Combustion Air

√
√

√
√

Rotary Dryers and Kilns
Solution Heating and Finishing Systems

√

√

√

√

• Nozzle-mixing line burner for use
with low pressure natural gas,
propane and butane
• Single-piece aluminum extrusion
body design eliminates leakage
• Cooler oven walls due to deeper penetration inside the oven (wallmount); Independent of variable process air flows (in-duct)
• Corrosion-resistant main gas/air body and durable stainless steel
mixing plates
• Up to 1.0 MMBtu/h per foot; Up to 40:1 turndown
• Packaged units up to 15 foot in length

NP-LE AIRFLO®
• Designed for direct-fired make-up
air and process applications
• Improved emissions over Maxon’s
earlier NP AIRFLO units, with significantly
lower CO and NO2 levels
• Shorter flame length
• Available in low pressure version and corrosion-resistant materials
• Easily meets ANSI/CSA standards
• Up to 1 MMBtu/h per foot; Up to 30:1 turndown

CROSSFIRE®
• Nozzle-mixing line burner for
use with low pressure natural
gas firing
• Extremely low emissions —
Capable of NOx levels of 25ppm and CO levels of 250ppm at 3% O2
• Temperature uniformity to enhance product quality
• Also available in stainless steel housings or nickel-plated body
• Up to 2.5 MMBtu/h per foot; Up to 25:1 turndown

UNI-RAD®

√

√

√
√
√
√

√
√

√
√
√

√

√

√

√

Steel Mills

APX®

√
√
√

√
√

OPTIMA™ SLS

√

KINEDIZER® LE

√

√

Low Emissions
Oven Burners

MEGAFIRE®

√

OVENPAK® 400

M-PAKT®

√

Heat Treating and Furnace Burners

KINEMAX®

OVENPAK® LE

TUBE-O-THERM®

CROSSFIRE®

√

√
√

TUBE-O-FLAME®

NP-LE AIRFLO®

Finding the right Maxon burner
for your application

APX®

Burner Systems for Industrial Applications

√

TUBE-O-FLAME®
• Nozzle-mixing refractory-less burners for
tube firing
• Burns any clean low-pressure fuel gas
• Increases heat transfer efficiencies with
long swirling flame pattern
• Flange-mounted compact design
for easy installation
• Low horsepower requirements
reduce initial and operating costs
• Produces low levels of NOx in combustion products
• Generates less noise than open-port tube firing
• Capacities to 5 MMBtu/h; Up to 20:1 turndown

TUBE-O-THERM®
• Burns natural gas, propane, or butane
• Burner-to-tube direct firing system allows
uniform heat transfer, eliminates hot
spots,and produces faster bring-up
times
• Fires directly into small-bore immersion tubes
• Designed with integral low-horsepower blower to lower costs and
save energy
• Wall- or tube-mount design for no-hassle installation and easy maintenance access
• UV flame scanner capability for all four sizes
• Capacities to 5.3 MMBtu/h

Maxon
information on
Look for more
rners,
bu
s,
l system
ro
nt
co
n
io
st
bu
.com
com
online at Lesman
ts
uc
od
pr
e
lv
and va

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

INDUSTRIAL
BURNERS

17

OVENPAK® LE

MEGAFIRE®

• Burns any clean fuel gas,and operates
on low gas supply pressures
• Provides clean combustion with low
NOx and CO levels
• Compact burner design provides
quick and easy installation
• Balanced pressure design and visible
ignition action for easy commissioning,
adjustment and maintenance
• Up to 6.5 MMBtu/h; Up to 100:1 turndown

• Provides clean burning of #2 oil,
natural gas or propane; Fires gas,
oil, or both simultaneously
• Inline blower version includes
energy-efficient centaxial direct
drive combustion air blower
• Quiet operation with exceptionally
low horsepower requirement
• Nine different styles, three different sizes
• Capacities to 45 MMBtu/h; 10:1 turndown on #2 oil, 15:1 turndown
on natural gas

M-PAKT®

KINEDIZER® LE

• Burns natural gas or propane
• Extremely low emissions — Capable of single-digit
NOx and CO levels at 3% O2
• Flame contained almost entirely inside the discharge sleeve
• Durable steel outer construction
with stainless steel internals
• Compact design with a variety of
control methods
• Up to 8.4 MMBtu/h; Up to 13.5:1 turndown

KINEMAX®
• Burns most clean low-pressure gaseous
fuels or light oil; Can be used with
oxygen-enriched combustion air
• Lower fuel consumption using
preheated combustion air (up to 800°F)
• Operate on-ratio with excess fuel or excess oil to meet specific demands of your
combustion process
• Exit velocities up to 275 ft/s to promote workload heat penetration
and better furnace temperature uniformity
• Refractory block for chamber temperatures up to 3000°F
• Removable backplate gives easy access for inspection, maintenance
• Seven sizes, capacities to 8.4 MMBtu/h; Up to 48:1 turndown

OVENPAK® 400
• Burns any clean fuel gas; Requires
only low-pressure gas
• Fires into passing air streams
• Provides clean combustion with low NOx
levels
• Simple field adjustment and maintenance
• Compact burner design provides quick
and easy installation
• More than 90 different styles and sizes
— including cost-effective external blower versions
• Capacities to 16.5 MMBtu/h; Greater than 40:1 turndown

• Burns natural gas, propane, or
other fuel gases
• Accepts preheated and vitiated
combustion air
• Field-proven low emissions; Stateof-the-art NOx firing, adjustable
for application flexibility
• Rugged design for oxidizers, process heaters, kilns, furnaces, dryers,
waste incineration, and other high-temperature applications
• Excellent stirring and mixing with medium velocity exhaust
• Six sizes, capacities up to 75 MMBtu/h; Up to 22:1 turndown, with the
lowest NOx and excess air in the KINEDIZER® family!

OPTIMA™ SLS
• Fuel flexible with natural gas, propane, and butane capability
• Low NOx and CO production levels
for extremely clean, reliable heat
— and easy air permitting and
environmental compliance
• Large capacity heat releases with a
compact, robust flame geometry
• Intelligent ratio control provides reliable operation and optimal fuel
efficiency
• All steel and high temperature alloy construction for reduced weight,
increased durability
• Configurable for dryers, air heaters, ovens, kilns, process heaters, paper
machines, and a variety of industrial heating equipment
• Direct factory operational support with SMARTFIRE® control and
communication gateway
• Five sizes, capacities to 93.5 MMBtu/h; Up to 17.8:1 turndown

UNI-RAD®
• Radiant tube burner for fuel gas inputs
• Suitable for use on pressure tubes,
negative pressure tubes, and electrified radiant tubes
• Flame length adjustable by changing
combustion air-to-ignition ratios —
produces optimum tube temperature uniformity over a wide range
of firing rates and preheated air temperatures
• Continuous plasma spark provides instantaneous ignition, so burner
can operate from the DAT output of a PID control loop
• Can be used in conjunction with UV flame supervision equipment

BURNER
CONTROLS

V 10.2008

18

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

MicroM Flame Safeguard Burner Control System
Model Selection Guide

MicroM Flame Safeguard controls
are compact, modular burn management systems designed to provide automatic ignition and continuous
flame monitoring for commercial-sized heating and process burners
firing any type of fuel.
The MicroM incorporates remote reset capability and serial
communications via MODBUS. The optional ED510 display can be
used to access burner hours and cycles, system hours, the last 6
lockouts with burner cycle time stamp and programmer configuration. MODBUS communications capability allows the integration
of the MicroM control into upper level energy management/data
acquisition systems.
A complete MicroM system consists of the appropriate flame
scanner/detector, plug-in amplifier, and programmer modules connected to a chassis and wiring base. Interchangeable programmer
and amplifier modules allow versatility in selecting control function,
timing, and flame scanning method.
All amplifiers are available with flame failure response times of
0.8 or 3 seconds nominal (4 seconds max), and each provide a set
of test jacks with a range of 0-10VDC for the measurement of flame
signal intensity.
Smart LED indicators on all programmer modules indicate the
current operating status of the control, and during a safety lockout,
display the fault as a coded sequence, simplifying troubleshooting
during a shutdown. A run-check switch is provided on the MEP500
series programmers to assist in testing size, position, and stability of
the pilot. A safety checking circuit runs on each start. If flame (real
or simulated) is detected prior to a start or during purge, the fuel
valves will not be energized and the control will lock out.

			
Catalog
AvailComponent Description
Number
ability
120VAC Input , Standard Board
MEC120
• • • •
Chassis
120 VAC Input with Remote Reset
		 Capability, Interface to Alphanu		 meric Display, Communications,
		 Modbus Capability
MEC120RC • • • •
Programmer Relight Operation, 10 Sec. PTFI
MEP100
• • • •
Selectable Purge Timing, PTFI
		 Timing, Recycle/Non-Recycle,
		 Post Purge, Prove Air Open at Start
MEP230
• • • •
Selectable Purge Timing to 60 Min.
MEP536
• • • •
Non Self-Checking Scanner, 3 Ft.
		 Flexible Cable, 1/2” NPT Connector
UV1A3
↓				
Non Self-Checking Scanner, 6 Ft.
		 Flexible Cable, 1/2" NPT Connector
UV1A6
↓				
Flame
Infrared Scanner, 8 Ft Shielded
Scanners		 Cable with 90° Head
48PT2-9003		 ↓			
(See pg 20
Ultraviolet Self-Checking Scanner,
for details)		 120 VAC Shutter, 1" NPT Threads
45UV5-1009			 ↓		
Flame Rod for Gas Flames, 12"
		 Length, 1/2" NPT Connection
69ND1-1000K4				 ↓
UV Amplifier, 0.8 Sec Flame Failure
		 Response Rate (FFRT)
MEUV1
•				
UV Amplifier, 3 Sec FFRT
MEUV4
•				
Infrared Amplifier, 0.8 Sec FFRT
MEIR1		 •			
Amplifier
Infrared Amplifier, 3 Sec FFRT
MEIR4		 •			
Modules
UV Self-Check Amplifier, 0.8 Sec FFRT
MEUVS1			 •		
UV Self-Check Amplifier, 3 Sec FFRT
MEUVS4			 •		
Flame Rod/Photocell Amplifier,
		 0.8 Sec FFRT
MERT1				 •
Flame Rod/Photocell Amplifier,
		 3 Sec FFRT
MERT4				 •
Wiring
Closed Wiring Base, Surface Mount
61-3060
• • • •
Base
Open Wiring Base, Cabinet Mount
61-5042
• • • •
Add functionality to your existing MicroM chassis*.
Standard Local Reset Switch
MED1
• • • •
Standard Local Reset Switch
		 with Display Output
MED2
• • • •
Standard Local Reset Switch
		 with Remote Reset
MED3
• • • •
Option
Standard Local Reset Switch
Boards		 with Communications
MED7
• • • •
Standard Local Reset Switch,
		 Display Output, and Remote Reset
MED4
• • • •
Standard Local Reset Switch with
		 Display Output, Communications
MED5
• • • •
Standard Local Reset Switch with
		 Display Output, Remote Reset,
		 and Communications
MED6
• • • •
*MicroM chassis model MEC120RC includes all these options.

MicroM Subbase Mounting Adapters
The MicroM can fit directly onto your existing Honeywell Flame Safeguard
mounting subbase with the addition of a single mounting adapter. No need to
do any rewiring or expensive re-engineering for retrofits.

Model Selection Guide
Description
MM-2 Mounting Adapter to Retrofit to R4795 Systems

Catalog
Number
60-1765

Price
$96.60

Price
$339.00

493.00
151.00
365.00
458.00
160.00
189.00
252.00
1373.00
106.00
74.30
74.30
149.00
149.00
160.00
160.00
74.30
74.30
64.50
68.50
35.10
58.30
81.70
129.00
117.00
142.00
175.00

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

BURNER
CONTROLS

19

BurnerLogix™ Burner Management System
Features
• Keypad-configurable parameters — no dip switches to set!
• Smart LEDs provide status and lockout codes — and provide operation without the need for the optional display
• Alphanumeric display provides clear, concise messaging
• Valve proof-of-closure during standby, startup, and shutdown
• Modbus communications built in — adjustable baud rates allow for
easy adaptation to burner control system
• Open wiring base with terminal block allows testing with control
installed; pigtail wiring base has color-coded and labeled leadwires
• 4-20 mA test jack signal
• New design with smaller footprint saves
cabinet space
BurnerLogix

Model Selection Guide

The Fireye Burner Logix System provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited
oil, gas, and combination fuel burners. In conjunction with limit and
operating controls, it programs the burner/blower motor, ignition and
fuel valves to provide for proper and safe burner operation.
A complete BurnerLogix system includes the YB110 chassis equipped
with a flame amplifier, appropriate flame detector, plug-in programmer
module, wiring base and optional alphanumeric display. The chassis/
flame amplifier module comes complete with mounting screws and
blank display module.
Interchangeable programmer modules allow for complete versatility
in selection of control function, timing, and flame scanning means. The
programming module determines functions like pre-purge time, recycling or non-recycling interlocks, high fire proving interlock, and trial for
ignition timing of the pilot and main flame.
The BurnerLogix system can be used with ultraviolet, auto-check infrared, flame rod, self-check ultraviolet flame scanners, or direct coupled
by choosing the proper chassis/flame amplifier module.
BurnerLogix’ operational characteristics are
determined by the selection of the programmer
module (e.g. modulation, recycle, non-recycle,
fixed firing, flame failure response time, etc.). The
programmer module incorporates a plug-in design
for easy installation.
Wiring bases for the BurnerLogix control are
available pre-wired with 4 foot lead wires color
coded and marked for easy installation or with an integral terminal block
capable of accepting up to 2X 14 AWG wires. The wiring base terminal
block is available with knockouts for conduit, or open ended for cabinet
mounting.

Catalog
Description
Number
Price
Step 1: Select Your BurnerLogix Chassis/Amplifier Module
120 VAC 50/60 Hz, with UV non-self-check amplifier
YB110UV $1023.00
120 VAC 50/60 Hz, with UV self-check amplifier
YB110UVSC 1262.00
120 VAC 50/60 Hz, with IR auto-check amplifier
YB110IR
1192.00
120 VAC 50/60 Hz, with flame rectification amplifier
YB110FR
1017.00
120 VAC 50/60 Hz, with direct-coupled amplifier, for
use with Phoenix and Insight scanners
YB110DC
1192.00
Step 2: Select Your BurnerLogix Programmer Module
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, 4 second FFRT
YP100
905.00
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, 2 second FFRT
YP102
905.00
Keypad-selectable parameters, non-recycle operation,
fixed TFI times, pilot proving, modulation, open
damper proving, 1 second FFRT
YP113
905.00
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, indefinite pilot
hold, revert to pilot from auto, 4 second FFRT
YP138
905.00
Keypad-selectable parameters, recycle operation,
modulation, 4 second FFRT
YP200
699.00
Keypad-selectable parameters, recycle operation,
modulation, 2 second FFRT
YP202
699.00
Keypad-selectable parameters, recycle operation, low
fire start, early spark termination, 4 second FFRT
YP300
525.00
Keypad-selectable parameters, recycle operation, low
fire start, early spark termination, 4 second FFRT
YP302
525.00
Step 3: Add an Optional BurnerLogix Display Module
Vacuum fluorescent display (VFD), Good -40° to 140°F
BLV512
520.00
Liquid crystal display (LCD), Good -4° to 140°F
BLL510
520.00
NEMA 4 remote mount kit for display, 4 foot cable
129-178-4
56.00
NEMA 4 remote mount kit for display, 8 foot cable
129-178-8
61.00
Step 4: Select a Wiring Base
4” x 5”, 4 foot pigtail wires, color coded and labeled
60-2810-1
93.20
4” x 7” closed base with terminal block and knockouts
60-2812-1
93.20
4” x 7” open base with terminal block
60-2814-1
93.20
Step 5: Add an Optional Expansion Module
Expansion module for first-out annunciation
YZ300
996.00
Step 6: Select a Flame Scanner (See page 20 for details)
Non Self-Checking Scanner, 3 Ft. Flexible Cable
UV1A3
160.00
Non Self-Checking Scanner, 6 Ft. Flexible Cable
UV1A6
189.00
Infrared Scanner, 8 Ft Shielded Cable with 90° Head
48PT2-9003
252.00
Ultraviolet Self-Checking Scanner 120 VAC Shutter
45UV5-1009 1373.00
12" Flame Rod for Gas Flames, 1/2" NPT Connection 69ND1-1000K4 106.00

Display Modules
The BurnerLogix system offers
vacuum fluorescent (VFD) and liquid crystal (LCD) displays that can
be either plugged in or mounted
remotely to give full language
descriptors of current status and diagnostic lockout information.
Both displays contain a fully functional keypad so you can easily scroll
through the various menus to view the current operating status, and
review programmer configuration and lockout history.
Remote mounted displays meet NEMA 4X requirements.

BURNER
CONTROLS

V 10.2008

20

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Flame Monitor Series Burner Control System
Flame-Monitor Series

Flame Scanners

The Flame-Monitor Series provides
the proper burner sequencing, ignition and flame monitoring protection
on automatically ignited oil, gas and
combination fuel burners.Inter­change­
able programmer and flame amplifier
modules allow complete versatility in
selecting control function. The flamemonitor control uses the same wiring
base as the Fireye D-Series and C-Series
Controls and is directly interchangeable
with most models with out rewiring.
The Flame-Monitor control can be
used with ultraviolet, AUTOCHECK® infrared, photocell, flame rod or self-check
ultraviolet flame scanners.Special features
include remote reset, remote display,
expanded annunciation of safety lockouts, programmability of safety
interlock messages, and remote data communications capability.
The complete Flame-Monitor control consists of a chassis, display
module, programmer, amplifier, scanner and a wiring base.

69ND1: Flame rod made
of high temperature resistant
metal. Can only be used to
detect gas flames. Rods are available in 12”, 18”, and 24” lengths.
UV1A: Ultraviolet miniature non selfchecking scanners suitable for fuel gases
and #2 oil.Non-replaceable tube.Mounting
collar 1/2” NPT.
48PT2: Lead sulfide scanner is designed to
detect low frequency IR signals from gas or oil
flames. Mounting collar is 1/2” NPT with straight
or 90° mounts. 8 ft. flexible conduit. Replaceable
sensor cell.
45UV5: Self-checking ultraviolet scanner for continuously fired applications where recycling in
infrequent or absent.The self-checking circuit
checks the electronics and the UV tube for
proper operation every 4 seconds during the firing
period.Suitable for fuel gases and oil.Replaceable UV
tube and shutter mechanism. Mounting 1” NPT. Must
be installed with metal shielding over the scanner leads.

EP Programmer Module

Flame Amplifier Module

The Fireye EP Programmer Modules
provide start-up programming, safe
start check, and flame monitoring supervision. They ensure open damper
high fire purge interlock, proof of low
fire position and fuel valve end switch
safety checks.
A running interlock circuit constantly
monitors the limit switches, air flow
switches and fuel pressure switches
throughout the programmer. EP programmer modules will de-energize all fuel valve circuits within 4 seconds
following a flame failure or at the end the pilot-trail-for-ignition period
if no flame is detected.
The EP programmers provide a Check-Run switch to stop the control
in its firing sequence at any time (except MTFI) to aid in setup, start-up,
and check out of the burner and its associated interlocks.
EP programmers offer the following functions: an increase of purge
timing and air flow switch opened at the start of the operating cycle.
EP programmers include an RJ45 style connector to interface with the
ED510 display module. EP programmers store the burner cycle and ontime history, as well as lockout history (with burner cycle and burner
hour time stamp).

ED510 Display Module
•
•
•
•

LCD backlit display with 2 lines of 16 characters each
RJ style connector
Mounts directly onto front face of programmers
Continuous display of current burner
status, including first out annunciation
in the event of a lockout condition
• Remote display using DIN-sized opening
and remote mounting kit.
• 3-key keypad provides historical data
from the burner, the last 6 lockout conditions (with burner cycle and burner hour
time stamp)

Flame amplifier modules are used with the
appropriate flame scanner to provide flame
scanning capability. Fireye offers ultraviolet
amplifiers and flame rectification amplifiers
for use with flame rods, photocells and autocheck infrared amplifiers.
Self-checking ultraviolet scanners and
amplifiers should be used in applications
where burner firing operation is continuous
or where the burner is on for long periods
of time without cycling.

Model Selection Guide
		
Catalog
AvailComponent Description
Number ability Price
Chassis 120VAC Chassis with Mounting
		 Screws and Dust Cover
E110
• • • • $701.00
Program 30 Sec. Purge, 10/15 Sec. TFI, 4 Sec.
Module		 FFRT, Non-Recycle Modulation
EP160
• • • • 952.00
Display 2 Line x 16 Character LCD
		 Display with Keypad
ED510
• • • • 494.00
Flame
Non Self-Checking Scanner, 3 Ft.
Scanner		 Flexible Cable, 1/2” NPT Conn.
UV1A3
↓				 160.00
Non Self-Checking Scanner, 6 Ft.
		 Flexible Cable, 1/2" NPT Conn.
UV1A6
↓				 189.00
Infrared Scanner, 8 Ft Shielded
		 Cable with 90° Head
48PT2-9003		 ↓			 252.00
Ultraviolet Self-Checking Scanner
		 120 VAC Shutter, 1" NPT Thread
45UV5-1009			 ↓		 1373.00
12" Flame Rod for Gas Flames,
		 1/2" NPT Connection
69ND1-1000K4				 ↓ 106.00
Standard Ultraviolet Amplifier
EUV1
•				 373.00
Amplifier Autocheck Infrared Amplifier
E1R1		 •			 552.00
Module Self-Check Ultraviolet Amplifier
EUVS4			 •		 625.00
Flame Rectification Amplifier
ERT1				 • 367.00
Wiring
Surface Mount
60-1386-2
• • • • 105.00
Base
Panel Mount
60-1466-2
• • • • 105.00

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

BURNER
CONTROLS

21

MB Series Industrial Multiburner Flame Safeguard System
Modulation for Purge and
Low Fire Start Control

A single MBPF amplifier module handles UV,
UV Self-Check and Flame Rod scanners

Four
Auxiliary
Inputs

Valve Leak
Detection
Interface

LED indicator alert you to
process step and status

Up to four
burner
amplifiers
mounted on
MB-600
Optional
Expansion
Modules for
control of up
to 20 burners

Connects to
optional Remote
Display Module

The Fireye Multi-Burner Monitoring System controls the start-up
sequence and monitors the flame of up to 20 individual gas, oil or
combination gas/oil burners connected to a common valve train.
Dynamic on-board diagnostics check for faulty relays, proof of valve
closure, high and low fire switch interlocks, and shortened air switch.
The MB is even able to specifically identify which burner caused the
initial flame failure.
Plug-in flame sensor modules that can sense UV, UV self-check or
flame rod provide for easy replacement on an individual basis. Configuration and startup time is reduced through use of on-board DIP
switches, which also allow sequencing and timing functions.
The MB-600S chassis directly powers pilot and main gas valves and
ignition transformers. The built in blower output, purge timing and
modulation control, let you add independent limits and a controller
to create a complete combustion control system for furnace, oven or
other multi-burner applications.
UV7A4 UV Scanner

Specifications
Number of Burners: 20 max.
UV7R4
90° UV Scanner
Pilot Proving Time: 7 seconds
Purge Time: 0 sec to 60 min
Pilot Trial for Ignition: 5, 10 or 15 seconds
UV7SC
Self-Check
Flame Failure Response Time: 3 (±0.5) seconds
UV Scanner
Valve Operation: Simultaneous (all burners operate from one fuel train)
Supply Voltage: 120VAC, 50/60 Hz; Power Consumption: 25VA
Temperature Rating: -32° to 122°F (-36° to 50°C)
Contact Ratings: Fan Motor: 15 Amp Resistive; Others: 10 Amp Resistive

Model Selection Guide
			
Catalog
Description			
Number
Price
Step 1: Select a Chassis for your Multiburner Control System
120VAC 50/60Hz, Motherboard, Relay
		 Board, Logic Module, and Power Module.
		 4 Auxiliary Inputs, Purge Modulation,
		 Valve Leak Testing
MB-600S $1769.00
120VAC 50/60Hz, Motherboard with RS-232
		 Communications, Relay Board, Logic
Chassis		 Module, Power Module. 4 Auxiliary Inputs,
		 Purge Modulation, Valve Leak Testing
MB-632S
1903.00
120VAC 50/60Hz, Motherboard with RS-485
		 Communications, Relay Board, Logic
		 Module, Power Module. 4 Auxiliary Inputs,
		 Purge, Modulation, Valve Leak Testing
MB-685S
1903.00
Step 2: Select a Flame Sensor Module
Sensor
Plug-In Flame Sensor Module, UV/FR
Module		 Plastic Case with Mounting Screws
MB-600PF
354.00
Step 3: For Systems with More than 4 Burners, Select Expansion Board Modules and Cables
Expansion Board for up to 4 Burners
MB-604E
316.00
Expansion Expansion Board for up to 8 Burners
MB-608E
638.00
Modules
6” Cable for Expansion Board
59-506-1
34.40
36” Cable for Expansion Board
59-506-3
48.60
Step 4: Select Optional Remote Display and Cable
Remote Display with Keypad
MB510
448.00
Display
6 Ft. Cable for Remote Display
59-507-6
23.60
10 Ft. Cable for Remote Display
59-507-10
35.40
Step 5: Select One Flame Scanner for Each Burner on Your System
1/2” NPT Straight UV Scanner, 4 Ft. Flex
		 Conduit, Insulated Nylon Coupling
UV7A4
181.00
1/2” NPT UV Scanner, NEMA 4, 4 Ft. Flex
Scanners		 Conduit, Insulated Nylon Coupling
UV7A4W
241.00
and
1/2” NPT 90° UV Scanner, 6 Ft Shielded Cable
UV7R4
148.00
Accessories 1” NPT Self-Check Scanner
UV7SC
970.00
10 Ft Cable for UV7SC Self-Check Scanner
59-504-010
150.00
Scanner Support, Max Temp 200°F
36-935
35.60
Magnifying Lens Assembly
46-185
90.60
Magnifying Lens
46-186
22.20
Non-Magnifying Lens
46-187
28.20
1/2” NPTF Insulated Nylon Coupling
35-319
17.40
Tip: If your system has between 4 and 8 burners, select 1 MB-604E module and a
connecting cable. If your system has between 9 and 13 burners, select 1 MB608E module and a connecting cable. For systems that have 14 to 20 burners,
you can mix MB-604E and MB-608E modules to fit.

65UV5 Integrated Flame Scanner with Internal Flame Relay
The 65UV5 flame scanner incorporates an internal single pole, single throw (normally open) flame
relay with a fixed on/off threshold to provide flame
on/flame off indication, eliminating the need for
an external flame amplifier.
The scanner uses an ultraviolet tube-type sensor, and electromechanical self-checking shutter
mechanism. The NEMA 4X/IP66 housing is suit-

able for use in Class I Division II, Group C and D
hazardous environments.
The Fireye 65UV5 flame scanner is powered
by 24 VDC and includes an integral 10-foot
four-conductor cable with cable gland. Two
color-coded internal LEDs indicate flame status (off/on) and alarm condition. These can
be viewed through the removable rear access
screw opening.

Model Selection Guide
Description
Integrated Flame Scanner, 1” NPT Mounting Flange, 4 Second Flame Failure Response Time

Catalog
Number
65UV5-1004

Price
$1544.00

BURNER
CONTROLS

V 10.2008

22

Lesman Instrument Company

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Flame Relays and Burner Control Units
Choosing the Right
Kromschroder Burner Control
Operating Time
Ignition Type

IFS 258

IFS 110IM

BCU 370

< 24 Hours

< 24 Hours

> 24 Hours

Direct

Direct

Direct or Pilot Burner

Signal Line Length

75M Max

50M Max

50M Max

Behavior at Flame
Failure

Switchable: Fault Lockout
or Restart

Fault Lockout
and/or Restart

Programmable

Gas Valve Outputs

1

2

2

IFS 258 Burner Control Unit
For use in single- and multiburner atmospheric or forced-air burner systems. Can be used
with on/off, high/low or proportional control. Add external timer to provide purge timing.
Model Selection Guide
• Compatible with flame rods or UV detectors
• Front panel indicators display burner unit on,
flame on, and flame failure information
• Start/stop/reset switch on front of unit
• Can be programmed to restart or immediate
fault lockout following flame failure
• CSA, FM approved

Pilot Flame
Catalog
Description
Establishing Period
Number
Price
Burner control unit for intermittent operation with switchable
fault lockout or restart, FFRT 2 seconds
IFS 258T-3/2R
3 seconds
84620420 $307.00
IFS 258T-5/2R
5 seconds
84620440
307.00
IFS 258T-10/2R
10 seconds
84620460
307.00

IFS 110IM Burner Control Unit
Automatic burner control for ignition and control of gas burners in gas-firing installations of
all types. Designed for high cycling frequency and long life.

T
Add an IFW 15
ur
yo
to
y
la
re
e
flam
r
fo
IM
IFS 110
rol.
multiburner cont

• Flame control by means of flame rods or Model Selection Guide
UV detectors
Pilot Flame
Catalog
• Performs flame simulation check before Description
Establishing Period Number
Price
starting burner and after switching off
Burner control unit for intermittent pilots, FFRT 2 seconds, fault
• Semiconductor output for ignition trans- lockout and restart following flame failure
former — no switch contacts
IFS 110IMT-3/2/2N
3 seconds
84367700 $414.00
IFS 110IMT-5/2/2N
5 seconds
84367710
414.00
• High cycling frequency
IFS 110IMT-10/2/2N
10 seconds
84367720
414.00
• Remote reset
Burner control unit for intermittent operation FFRT 2 seconds,
• External fault indication
restart following flame failure
• FM approved
IFS 110IMT-W-3/2/2N
3 seconds
84367750
434.00
• Can be used for multiburner control by IFS 110IMT-W-5/2/2N
5 seconds
84367760
434.00
adding flame relay IFW 15T
IFS 110IMT-W-10/2/2N
10 seconds
84367770
434.00

IFW 15T Flame Relay
Detect and signal existing flame.
•
•
•
•
•

Compatible with flame rods or UV detectors
Potential-free contacts
Integrated ON lamp
Use with IFS 110IM for multiburner control
Great for letting your PLC know when flame is present

Model Selection Guide
Catalog
Description
Number
Price
Flame relay. Use with IFS 110IM burner control
for multiburner apps.
IFW 15T-N Flame Relay
84359100 $200.00

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

BURNER
CONTROLS

23

BCU 370 Burner Control Unit
Controls, ignites, and monitors industrial forced-air burners of unlimited capacity in
intermittent or continuous operation. Can be used for direct-ignited or pilot-burner systems.
• Controls fan and butterfly valve, monitors gas and air pressure
• Manual operating mode and informative operating, warning, and fault messages make startup, service, and
and maintenance simple
• Optional integrated tightness control function checks valves with a DG gas pressure switch
• Quick-start option allows standard-compliant startup of forced air burner without pre-purge after normal
shutdown
• Programmable via optical interface and BCSoft PC software

Model Selection Guide
Catalog
Description
Number
Price
For controlling, igniting, and monitoring industrial forced-air burners, intermittent operation, ionization or UV control.
120 VAC 50/60 Hz power, fan (blower) and butterfly valve control
BCU 370QFEU0D1 No ignition unit, flame control DGmax
88600122
$530.00
BCU 370QI1FEU0D1 Single-pole electronic ignition, flame control DGmax
88600249
650.00
BCU 370QI1FEU0D1B1 Single-pole electronic ignition, flame control DGmax,
ProfiBUS-DP interface
88600236
858.00
BCU 370QFEU0D3B1-3 No ignition unit, integrated tightness control, ProfiBUS-DP interface
and butterfly valve control over ProfiBUS
88600121
1111.00
Opto Adapter and BCSoft CD-ROM for BCU 370s

74960437

263.00

UVS 8T Ultraviolet Flame Detector
For use in forced and induced draft burners, ovens, gas-fired boilers, industrial furnaces, and
installations for the flaring of excess gas.
•
•
•
•

High sensitivity over an ambient temperature range -40° to 176°F
Insensitive to sunlight, daylight, infrared radiation, and incandescent lamps
UV tube life expectancy of 10,000 operating hours
Protects against interruptions or short circuits in the flame Model Selection Guide
signal line
Catalog
• Rugged aluminum construction with integral 1/2” NPTF Description
Number
threaded collar and 6-foot leads
UVS 8T Ultraviolet Detector 84333120
UV Replacement Tube
74960445
• FM approved

Price
$134.00
111.00

Coming soon to Lesman.com:
Buy Kromschroder burner controls from
our secure web store!

When you need to learn more, the
Lesman website has:
• Downloadable specifications
• Dimensional drawings
• 24/7/365 availability
Visit us anytime at www.lesman.com

PRESSURE
CONTROLS

V 10.2008

24

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Pressure Switches for Gas Applications
DG Pressure Switches
Monitors positive air and gas
pressures, negative or differential
air pressures in industrial and
commercial applications.
• Accurate repeatable switching action
with low hysteresis
• Die-cast aluminum alloy base,glass fiberreinforced plastic switch housing, nitrile
rubber diaphragm, and high-quality
injection-molded plastic covers
• One normally open and one normally
closed contact in each switch (5A resistive or 0.5A inductive
• Automatic and manual reset models
• 8A quick-acting fuse for short circuit
protection
• FM approved, cULus listed

Model Selection Guide
Adjustable		
Catalog
Description
Range
Connection
Number
Price
DG..T pressure switch with 110V control lamp (green) for positive,
negative, and differential pressure, automatic reset
DG 6T
0.2” to 2.4” WC
1 x 1/4” NPT
84447800 $64.00
DG 10T
0.4” to 4” WC
1 x 1/4” NPT
84447810
64.00
DG 50T
1.0” to 20” WC
1 x 1/4” NPT
84447820
64.00
DG 150T
12” to 60” WC
1 x 1/4” NPT
84447830
64.00
DG 500T
40” to 200” WC
1 x 1/4” NPT
84447840
64.00
DG 6T
0.2” to 2.4” WC
2 x 1/4” NPT
84447802
63.00
DG 10T
0.4” to 4” WC
2 x 1/4” NPT
84447812
63.00
DG 50T
1” to 20” WC
2 x 1/4” NPT
84447822
63.00
DG 150T
12” to 60” WC
2 x 1/4” NPT
84447832
63.00
DG 500T
40” to 200” WC
2 x 1/4” NPT
84447842
63.00
DG..HT pressure switch with manual reset, locks on pressure rise
DG 10HT
0.4” to 4” WC
2 x 1/4” NPT
84447912
77.00
DG 50HT
1.0” to 20” WC
2 x 1/4” NPT
84447922
77.00
DG 150HT
12” to 60” WC
2 x 1/4” NPT
84447932
77.00
DG 500HT
40” to 200” WC
2 x 1/4” NPT
84447942
77.00
DG..NT pressure switch with manual reset, locks on pressure fall
DG 10NT
0.4” to 4” WC
2 x 1/4” NPT
84447962
77.00
DG 50NT
1.0” to 20” WC
2 x 1/4” NPT
84447972
77.00
DG 150NT
12” to 60” WC
2 x 1/4” NPT
84447982
77.00
DG 500NT
40” to 200” WC
2 x 1/4” NPT
84447992
77.00

DG..VT Safety Limit Pressure Switches
Diaphragm-actuated safety limit switch controls rising or falling pressures that must not
overshoot or undershoot a set limit Model Selection Guide
value, and controls the minimum
Adjustable		
Catalog
Range
Connection Number
Price
or maximum gas inlet pressure of a Description
DG
pressure
switch
with
4-pin
plug,
socket,
and
18”
flexible
leads
gas control line.
• For use with natural gas and air
• Die-cast aluminum base, glass-filled PBT
switch housing, NBR diaphragm, and
polycarbonate cover
• Available with Valvario mount for direct
connection to Kromschroder modular
valve trains
• Ambient temperatures 5° to 140°F
• 4-pin DIN/Amp plug wiring connector

DG 17VCT6-6W
DG 40VCT6-6W
DG 110VCT6-6W
DG 300VCT6-6W
DG 17VCT8-6W
DG 40VCT8-6W
DG 110VCT8-6W
DG 300VCT8-6W
DG 17/VCT1-6W
DG 40/VCT1-6W
DG 110/VCT1-6W
DG 300/VCT1-6W

0.8” to 6.8” WC
2.0” to 16” WC
12” to 44” WC
40” to 120” WC
0.8” to 6.8” WC
2.0” to 16” WC
12” to 44” WC
40” to 120” WC
0.8” to 6.8” WC
2.0” to 16” WC
12” to 44” WC
40” to 120” WC

1/8 NPTM
1/8 NPTM
1/8 NPTM
1/8 NPTM
1/4” NPTM
1/4” NPTM
1/4” NPTM
1/4” NPTM
Valvario
Valvario
Valvario
Valvario

84448040
84448840
84448440
84448940
84448090
84448890
84448490
84448990
75454583
74214174
75454585
75454586

$49.00
49.00
49.00
49.00
49.00
49.00
49.00
49.00
78.00
78.00
78.00
78.00

The new RAECO Rents instrumentation
catalog is now available! Get yours FREE!
• Looking for portable LEL monitors or combustion efficiency analyzers? Check with
our partners at RAECO!
• Rentals available on a daily, weekly, or monthly basis
• All parts, accessories, and software available
• Automatic 5% rental fee discount when you rent online at www.raeco.com
Visit www.raeco.com to request a print catalog or download the free PDF.

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

BUTTERFLY
VALVES

25

Butterfly Valves and Actuators
BV Butterfly Valves
High accuracy valves for control of gas flow rates. Mount on IC 20 or IC 40 actuators to
regulate flow rates for modulating or stage-controlled combustion systems.
• Low leakage rate and pressure loss
• Other models available for flue gas and high temperature air flow rates to 840°F. Call Lesman for details

Model Selection Guide
Temperature
Bore
Nominal
Reduced
Compatible
Catalog
Model
Range
Size
Diameter Nominal Diam.
Actuator
Number
Butterfly valve for continuous control of gas flow rates, ratio of 10:1. Maximum inlet pressure 7.25 PSI.
BVG 40TW05
-4° to 140°F
Full
1 1/2”		
IC 20 or IC 40
74105790
BVG 65TW05
-4° to 140°F
Full
2 1/2”		
IC 20 or IC 40
74105792
BVG 50TW05
-4° to 140°F
Full
2”		
IC 20 or IC 40
74105791
BVG 80TW05
-4° to 140°F
Full
3”		
IC 20 or IC 40
74105793
BVG 100TW05
-4° to 140°F
Full
4”		
IC 20 or IC 40
74105794
BVG 40/32TW05
-4° to 140°F 1X Reducing
1 1/2”
1 1/4”
IC 20 or IC 40
74214264
BVG 50/40TW05
-4° to 140°F 1X Reducing
2”
1 1/2”
IC 20 or IC 40
74214263
BVG 65/50TW05
-4° to 140°F 1X Reducing
2 1/2”
2”
IC 20 or IC 40
74214262
BVG 80/65TW05
-4° to 140°F 1X Reducing
3”
2 1/2”
IC 20 or IC 40
74105783
BVG 100/80TW05 -4° to 140°F 1X Reducing
4”
3”
IC 20 or IC 40
74105784
BVG 40/25TW05
-4° to 140°F 2X Reducing
1 1/2”
1”
IC 20 or IC 40
74214267
BVG 65/40TW05
-4° to 140°F 2X Reducing
2 1/2”
1 1/2”
IC 20 or IC 40
74214265
BVG 50/32TW05
-4° to 140°F 2X Reducing
2”
1 1/4”
IC 20 or IC 40
74214266
BVG 80/50TW05
-4° to 140°F 2X Reducing
3”
2”
IC 20 or IC 40
74105875
BVG 100/65TW05 -4° to 140°F 2X Reducing
4”
2 1/2”
IC 20 or IC 40
74105782

Price
$196.00
226.00
208.00
257.00
273.00
255.00
294.00
316.00
361.00
376.00
255.00
316.00
294.00
361.00
401.00

Compatible Valve Actuators for BV Butterfly Valves
Reversible gear motors to transmit rotary movements between 0° and 90°.
• IC 20 for basic applications with continuous or three-point step control, automatic/manual mode changeover
for easy commissioning. IC 20..E is controlled by 0/4-20 mA or 0-10V signal
• IC 40 for complex applications with programmable functions for flexible adjustment to the process. Compatible with BCSoft for data monitoring, troubleshooting, and programming

Model Selection Guide
Torque
Run Time
Controlling
Description
(Lb-in)
(Over 90° Stroke)
Signal
IC 20 Reversible gear motor, 120 VAC, 50/60 Hz
IC 20-07Q2
22 Lb-in
7.5 seconds
Three-point step
IC 20-15Q3
26.5 Lb-in
15 seconds
Three-point step
IC 20-30Q3
26.5 Lb-in
30 seconds
Three-point step
IC 20-60Q3
26.5 Lb-in
60 seconds
Three-point step
IC 20-07Q2E
22 Lb-in
7.5 seconds
Continuous
IC 20-15Q3E
26.5 Lb-in
15 seconds
Continuous
IC 20-30Q3E
26.5 Lb-in
30 seconds
Continuous
IC 20-60Q3E
26.5 Lb-in
60 seconds
Continuous
Torque		
Description
(Lb-in)
Additional Input/Output Functions
IC 40 Reversible gear motor, 100-230 VAC, 50/60 Hz
IC 40TA2
22 Lb-in
—
IC 40TA2A
22 Lb-in
4-20 mA input
IC 40TA2R10
22 Lb-in
1000Ω feedback potentiometer
IC 40TA2AR10
22 Lb-in
4-20 mA input and 1000Ω feedback potentiometer
IC 40TSA3
26.5 Lb-in Safety closing function
IC 40TSA3A
26.5 Lb-in Safety closing, 4-20 mA input
IC 40TSA3R10
26.5 Lb-in Safety closing, 1000Ω feedback potentiometer
IC 40TSA3AR10 26.5 Lb-in Safety closing, 4-20 mA input, 1000Ω feedback potentiometer
Loose (/B)
IC 20/40 Attachment Set
74921671
$74.00
IC 20/40 Adapter - Free Shaft End
74921676
60.00
IC 20/40 Adapter - Manual Adjustment
74921678
47.00
IC 20/40 Adapter - Square Shaft
74921674
74.00
IC 40 Accessory: Fastening Set IC-BV
74921082
8.00

Catalog
Number
74105712
74105713
74105714
74105715
74105998
74105999
74106000
74106001
Catalog
Number

Price
$311.00
311.00
311.00
311.00
741.00
741.00
741.00
741.00
Price

74105760 $603.00
74105761
620.00
74105762
691.00
74105763
746.00
74105764
736.00
74105765
795.00
74105766
820.00
74105767
879.00
Assembled /E)
74921747
$69.00
74921677
68.00
52.00
74921679
74921675
69.00
74921084
9.00

y
Need a butterfl
s
ga
ue
fl
r
fo
valve
ture
or high tempera ll
Ca
air flow rates? g
in
ic
pr
r
fo
Lesman
y.
lit
bi
la
ai
and av

SOLENOID
VALVES

V 10.2008

26

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Compact Solenoid Valves
Valvario® VAS Safety Shut-Off Solenoid Valves
Normally closed solenoid valves for gas. For safeguarding and controlling air and
gas supply to gas burners and appliances. For use in gas control and safety systems
in all sectors of the iron, steel, glass, and ceramics industries, plus commercial heat
generation in packaging, paper, and food industries.
• Modular design saves space and piping work
• Main gas valve, pilot valve, regulator and pressure switch are all available for direct “stack” mounting
for one small modular footprint
• Changeable mounting plates make it easy to reduce input/output size and flange size. Reduces need
for keeping multiple sizes in inventory
• Modular-mount mercury-free pressure switch has test port and <25% deadband
• Can be equipped with Proof of Closure visual indicator
• High flow rate and low pressure drop
• CSA, FM, CE approvals

Model Selection Guide

Flow Rates

Specifications
Inlet Pressure: (pe): 7 PSIG max
Non-Operational Pressure: FM approved: 10 PSIG; CSA approved: 5 PSIG
Flow Adjustment: Limits max flow between 20% and 100%. On VAS 1-3 sizes,
the setting can be monitored on an indicator
Adjustment of Start Gas Rate: 0% to 70%
Opening Times: VAS/N quick opening: ≤1sec; VAS/L slow opening: up to 30 sec
Closing Time: <1 second
Ambient Temperature: -4° to 140°F
Safety Valve: Class A, Group 2, pursuant to EN 13611 and EN 161; FM research
class 7410 and 7411, ANSI Z21.21, CSA 6.5
Materials: IP65 enclosure; Valve housing: Aluminum, Valve seal: NBR
Voltage: 120 VAC, 50/60 Hz
Current Consumption (at 68°F): Pickup: 1.8 amp; Holding: 0.3 amp
Switching Frequency: 5x per minute, except VAS 9: Once per minute
Switching Cycles: 0.1 amp: 500,000; 0.5 amp: 300,000; 1 amp: 200,000; 3 amp:
100,000

Valve Inlet/Outlet
Catalog
Series
Size Flange Size
Number
Price
VAS Quick Opening, NPT Threaded Connection
VAS 1T10N/NQ
1
3/8”
88001831
$181.00
VAS 1T15N/NQ
1
1/2”
88001832
181.00
VAS 1T20N/NQ
1
3/4”
88001842
215.00
VAS 1T25N/NQ
1
1”
88001830
224.00
VAS 2T25N/NQ
2
1”
88001849
288.00
VAS 2T32N/NQ
2
1 1/4”
88001850
288.00
VAS 2T40N/NQ
2
1 1/2”
88001851
296.00
VAS 2T50N/NQ
2
2”
88001852
296.00
VAS 3T40N/NQ
3
1 1/2”
88001853
404.00
VAS 3T50N/NQ
3
2”
88001854
404.00
VAS 3T65N/NQ
3
2 1/2”
88001855
432.00
VAS Quick Opening, ANSI Flanged Connection, No Accessory Connection
VAS 6T65A05NQP
6
2 1/2”
88200132
854.00
VAS 7T80A05NQP
7
3”
88200148
1357.00
VAS 8T100A05NQP
8
4”
88200162
1835.00
VAS 9T125A05NQP
9
5”
88200160
2923.00
VAS Quick Opening, ANSI Flanged Connection, Two Screw Plug
Connections for Accessory Connections at Right Inlet/Outlet
VAS 6T65A05NQP/PP/PP
6
2 1/2”
88200385
1028.00
VAS 7T80A05NQP/PP/PP
7
3”
88200390
1533.00
VAS 8T100A05NQP/PP/PP
8
4”
88200394
2014.00
VAS 9T125A05NQP/PP/PP
9
5”
88200427
3106.00
VAS Slow Opening, NPT Threaded Connection
VAS 1T10N/LQ
1
3/8”
88001856
226.00
VAS 1T15N/LQ
1
1/2”
88001857
226.00
VAS 1T20N/LQ
1
3/4”
88001858
269.00
VAS 1T25N/LQ
1
1”
88001859
269.00
VAS 2T25N/LQ
2
1”
88001860
333.00
VAS 2T32N/LQ
2
1 1/4”
88001861
333.00
VAS 2T40N/LQ
2
1 1/2”
88001862
342.00
VAS 2T50N/LQ
2
2”
88001863
342.00
VAS 3T40N/LQ
3
1 1/2”
88001864
450.00
VAS 3T50N/LQ
3
2”
88001865
450.00
VAS 3T65N/LQ
3
2 1/2”
88001869
479.00
VAS Slow Opening, ANSI Flanged Connection, No Accessory Connection
VAS 6T65A05LQP
6
2 1/2”
88200133
936.00
VAS 7T80A05LQP
7
3”
88200149
1439.00
VAS 8T100A05LQP
8
4”
88200163
1917.70
VAS Slow Opening, ANSI Flanged Connection, Two Screw Plug
Connections for Accessory Connections at Right Inlet/Outlet
VAS 6T65A05LQP/PP/PP
6
2 1/2”
88200387
1110.00
VAS 7T80A05LQP/PP/PP
7
3”
88200391
1615.00
VAS 8T100A05LQP/PP/PP
8
4”
88200395
2095.00

Lesman Instrument Company

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

www.lesman.com
sales@lesman.com

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

SOLENOID
VALVES

27

Solenoid Valves for Combustion Systems

Comparing ASCO Combustion Valves
Valve
Parts In
Contact
with
Fluids

Approvals

8030

8040

8210

8214

8215

8262

Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs

Aluminum body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs
Zinc-plated steel pipe
plug

Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil

Aluminum body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs
Zinc-plated steel pipe
plug

Aluminum body
305 SS core tube
NBR seals/disc/
diaphragm
430F SS core/plugnut
302 SS or 17-7 PH
springs
Copper shading coil
CA core guide
305 SS core tube

Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
Inconel 600 springs
Acetal core guide
PTFE rider ring

UL, FM, CSA

UL, CSA,
FM (3/8” to 3/4” only)

UL, FM, CSA

UL, FM, CSA

UL, CSA,
FM (except 8215A090
and 8215A040)

UL, FM, CSA

Model Selection Guide

120 volts AC/60 Hz — All Valves Shown Here are Normally Closed (Closed when De-Energized), Suitable for Use in Fluids to Maximum Temperatures 125°F
Operating Pressure
			
Cv
Gas
Differential (PSI)
Pipe
Orifice
Flow
Capacity			
Size
Size
Factor
BTU/Hr
Min.
Max.
Direct Acting Gas Shutoff Valves
1/8”
5/16”
1
53,700
0
15
1/4”
9/32”
0.96
51,700
0
40
1/4”
5/16”
1.1
59,000
0
15
3/8”
3/8”
1.8
97,000
0
15
1/2”
7/16”
2.8
151,000
0
8
1/2”
3/4”
5.4
291,000
0
2
3/4”
3/4”
9.5
512,000
0
2
1”
1-5/8”
16.8
900,000
0
0.5
Pilot Operated Gas Shutoff Valves
3/8”
5/8”
2.8
150,000
0
50
3/8”
3/4”
3.4
183,000
0
50
1/2”
5/8”
3.6
193,000
0
50
1/2”
3/4”
4.4
238,500
0
50
3/4”
5/8”
5.0
295,000
0
50
3/4”
3/4”
5.1
247,500
0
50
3/4”
1-5/8”
11
580,000
0
50
1”
1-5/8”
21
1,119,000
0
25
1-1/4”
1-5/8”
32
1,730,000
0
25
1-1/2”
1-5/8”
35
1,900,000
0
25
2”
2-3/32”
60
3,251,000
0
25
2-1/2”
3”
117
5,821,000
0
5
3”
3”
138
7,430,000
0
5
Gas Shutoff Valves with Waterproof Enclosures
3/8”
3/4”
3.4
183,000
0
5
1/2”
3/4”
4.4
238,500
0
5
3/4”
3/4”
5.1
247,500
0
5

Watt Rating/
Class of
Coil
Insulation

Solenoid Valve
Catalog
Number

Price
Each

Repair Kit
Catalog
Number

Price
Each

Replacement Coil
Catalog
Number

Price
Each

6.1/F		
10.1/F		
10.1/F
10.1/F		
10.1/F		
10.1/F
10.1/F		
15.4/F		

8040H006
8262G078
8040H007
8030G068
8030G069
8040G022
8040G023
8040C004

$64.00		
65.00		
65.00		
154.00		
157.00		
127.00		
132.00		
158.00		

318247
306631
318247
306628
306629
306633
306633
304079

$66.00
47.00
66.00
104.00
108.00
63.00
63.00
104.00

238210-032-D
238610-032-D
238210-032-D
238610-032-D
238610-032-D
238610-032-D
238610-032-D
099257-001-D

$61.00
69.00
61.00
69.00
69.00
69.00
69.00
91.00

10.1/F		
10.1/F
10.1/F		
10.1/F
10.1/F		
10.1/F
15.4/F		
15.4/F
15.4/F		
15.4/F
15.4/F		
28.2/F		
28.2/F		

8210G074
8215G010
8210G075
8215G020
8210G076
8215G030
8215 135
8215B050
8215B060
8215B070
8215B080
8215A090
8215A040

179.00		
135.00		
179.00		
135.00		
196.00		
139.00		
250.00
252.00
252.00
292.00
428.00		
835.00		
835.00		

304076
302350
304076
302350
304076
302350
302352
302352
302352
302352
302353
302354
302354

128.00
104.00
128.00
104.00
128.00
104.00
184.00
184.00
184.00
184.00
221.00
362.00		
362.00		

238610-032-D
238610-032-D
238610-032-D
238610-032-D
238610-032-D
238610-032-D
099257-001-D
099257-001-D
099257-001-D
099257-001-D
099257-001-D
206409-011-D
206409-011-D

69.00
69.00
69.00
69.00
69.00
69.00
91.00
91.00
91.00
91.00
91.00
188.00
188.00

143.00
143.00
143.00

238610-132-D
238610-132-D
238610-132-D

83.00
83.00
83.00

17.1/F		 8214G010
17.1/F
8214G020
17.1/F		 8214G030

135.00		 316233
135.00		 316233
139.00		 316233

Looking for another ASCO solenoid valve? Call Lesman’s solenoid valve specialists at 800-837-1700. We stock deep!

STACK GAS
ANALYZER

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

V 10.2008

28

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Stack Gas and Combustion Efficiency Analyzers
Zircomat In-Situ Stack Gas Oxygen Analyzer

Probe

Stack Gas Out

Detector
Stack
Wall

Features
• Simple to install and maintain
• One detector fits all Zircomat
probes
• Detector removes for easy cleaning and repair; probe stays in
place
• Calibrates automatically

•
•
•
•
•
•

Field selectable ranges
Selectable memory hold feature
Hi-Lo and self-diagnostic alarms
Interactive message panel
Isolated 4-20 mA output signal
Extractive sample cell available

Call Lesman for
the
help specifying
fo
right model r
your application.

Stack Gas In

Refineries and power plants measure excess oxygen to improve their
energy efficiency and reduce fuel consumption.
In most oxygen analyzers, the electronic sensor comes in direct contact
with the sample gas, so you have to remove the hot probe every time
you service the sample gas filter or the sensor. And, you need to stock
probe-length-specific spare parts inventory for these systems.
Cosa Zircomat oxygen analyzers are more user-friendly.In the Zircomat
system, the sample gas is deflected to the sensor. To increase safety, the
probe always stays in the stack. The small, hand-held oxygen detector is
quickly detachable for service. And, one detector fits all Zircomat probes,
any model any length!
Small and easily detachable, the Zircomat detector can be serviced
without removing the probe from the flue stack. You won’t need to shut
down your plant just to remove the probe. A replaceable sample gas
diffuser on the end of the detector provides sensor protection.
The microprocessor-based transmitter has a large LED display for
oxygen concentration and a 4-20 mA isolated output signal. It’s simple
to run a manual or automatic calibration check using known value gases
to flow a calibration gas through the detector’s calibration gas port —
without removing the detector from the process.
The Zircomat transmitter can monitor and analyze performance of up
to seven parameters online. Failure to meet any of these specifications
will activate alarm contact. The self-cleaning probe feature is programmable from the keypad, and activates a solenoid valve for blow-back
probe cleaning.You can use the interactive panel to customize response
time to process changes to suit existing combustion
control parameters.

Looking for COSA portable combustion
efficiency analyzers? Call Lesman.
Selecting the Right Zircomat Analyzer System

Specifications

Sensor: Zirconia oxide
Measurement Range: 0-2%, Up to 50%
0.5% steps
Output Signal: 4-20 mA, linear isolated
Accuracy: ±2% of reading; Repeatability: ±0.5%
Response Time: Initial 0.1 sec./90% 7 sec; Warm Up Time: 5 minutes
Probe Materials: ZFK/ZTB: Steel, ZTA: Carbide, ZFK-ST: Mullite
Probe Flange: ZTB/ZFK/ZFK-ST: 4” 150#RF; ZTA: 2.5” 150#RF
Cable: 20 ft. Sealtite flexible conduit, up to 1000 ft. optional
Air Requirement: Self-Cleaning Probe: 15 SCFM, 40-120 PSI;ZTA Probe Sample
Loop: 10-20 SCFH
ZTA Probe: Low temperature alarm below 100°C, volt; free 1A 115V contact
closure

Transmitter
Ambient Temperature: 0-130°F
High/Low Alarms: Rated N/O volt free 2A 250V
Contacts: Outputs: Rain resistant; Inputs: Autocal start/inhibit; Alarm: Failure
in service, maintenance blow down
Calibration: Manual or automatic
Output Signal Hold: Selectable, for self-cleaning or maintenance
Finish: Epoxy painted steel/SS
Mounting: Wall, panel, or 2” pipe mount
Options: Combustion efficiency, RS485 communication, remote calibration
unit with solenoids and flow meter; Hazardous area transmitter

Please issue all orders to: Cosa Instruments, c/o Lesman Instrument Company

Fuel Type

Gas or Oil

Gas or Oil

Coal, Oil, or Gas

Coal, Oil, or Gas

Sample Gas

Up to 1150°F

Up to 2200°F

Up to 2900°F

Up to 1150°F

Available
Probe Lengths

12, 20, 30, 40, 60, 80,
100, 120, 140

20, 40

20, 30, 40, 60

12, 20, 30, 40, 60, 80,
100, 120, 140

Applications

Utility/Industrial Power
Boilers, Process Heaters,
Marine Boilers, Drying
Furnaces, Steam Gener­
ators, Inert Gas Generators

Process Heaters, Steam
Generators, Power Boilers

Soaking Pits, Blast Furnaces,
Coke Ovens, Incinerators,
Glass Furnaces, Boiler
Fireboxes, Process Heaters,
Reheat Furnaces

Utility/Industrial Power
Boilers, Incinerators, Blast
Furnaces, Coke Ovens, Black
Liquor Boilers

Use Model...

ZRM-ZFK

ZRM-ZFK-ST

ZRM-ZTA

ZRM-ZTB

Prices Start at...

$4796.00

$4996.00

$7216.00

$5073.00

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

EFFICIENCY
ANALYZER

29

Portable Combustion Efficiency Analyzers
866-RENT-EHS
(866)736-8347
Our partners at RAECO make it easy to get the combustion efficiency analysis equipment you need,
without a major outlay of cash. When you need portable combustion analyzers for short-term use, RAECO
Rents! has units for daily, weekly, or monthly rental. So you get the best monitor/analyzer for your needs,
just for the time you need it. No big purchase, no maintenance and upkeep costs. Call 866-736-8347 and
ask for Patricia or Rick.

Testo 330-2 Industrial Combustion Analyzer
• Measures O2, CO, NO (CO2 and NOx calculated), temperature °F, pressure,
efficiency, and excess air
• Automatic sensor protection (CO dilution to 30,000 ppm); Automatic
moisture protection; includes visual alarm and pump shut-off
• Datalogs 200 measuring records, with address and system numbers
• Infrared (IrDA) interface for working with a handheld PDA, infrared printer,
or laptop PC, USB interface for configuration and data uploads
Testo 330-2 Kit comes with 12" click-and-go probe, 7' hose, rechargeable Lithium Ion battery, charger with cord,
infrared printer with paper, carrying strap, standard case with foam insert, USB cable, software, and user manual.

Testo 335 Portable Flue Gas Analyzer
• Measures O2, CO, NO draft, flow, velocity, mass, differential pressure
• Automatic dilution expands CO range to 50000 ppm, NO to 6000 ppm
• Pre-calibrated plug-and-play sensors eliminate the need for calibration gas
in all but the most demanding applications
• Datalogging for up to two hours
• Infrared interface for printer, handheld PDA, or laptop PC
Testo 335 NOx Kit comes with standard 12" probe, 7-foot Teflon®-lined hose, Type K thermocouple, sensors for
NOx, O2, CO, and NO, infrared printer with 6 rolls of paper, power adapter with Lithium Ion battery, extra battery and
charger, 10-pack of filters, Easy Emission software, USB cable, and standard case with foam insert.

$100.00
Daily
$250.00
Weekly
$700.00
Monthly
$3590.00
to Buy
$123.00
Daily
$410.00
Weekly
$1025.00
Monthly
$3795.00
to Buy

Testo 350-XL Portable Emissions Analyzer Kit
•
•
•
•
•
•

Sensors for O2, CO, NO, NO2 (NOx), SO2
Temperature-controlled sensors extend testing range
Sample conditioning with Peltier gas chiller and water removal system
Dilution system 40:1 max. extends CO range to well over 100,000 ppm
Fresh air purge; Rapid set-up for easy measuring
Large backlit display has multipage scroll-down, zoom function, and pulldown menus

Testo 350-XL Engine Kit comes with gas sensors for CO, O2, NO, NO2 and SO2, control unit, particulate filters,
printer paper, carrying case and strap, transport case with sliding drawer, 12" engine probe with 7' hose and 12"
thermocouple probe with 16' cable, RS232 cable, software, and 16' remote control cable.

$200.00
Daily
$500.00
Weekly
$1500.00
Monthly
$8990.00
to Buy

CA-Calc 6213 Combustion Analyzer for O2, CO, NO, SO2
•
•
•
•

Real-time measurement seconds after power-up
Calculates efficiency, excess air, CO2, and emission rates, provides NO2 values
Adjustable CO high limit pump shutdown; Adjustable O2 reference
Data history sorted by system, or individual sample for printouts and report
generation

CA-Calc 6213 includes 12” probe with 9-foot sampling tube, Teflon-lined sampling probe, water trap,
carrying case, AC adapter, four C Alkaline bat­teries, and operation manual.

$100.00
Daily
$200.00
Weekly
$700.00
Monthly

COMBUSTIBLE
GAS MONITORS

V 10.2008

30

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

Portable Combustible Gas Detectors from
866-RENT-EHS
(866)736-8347

Choosing the Right Combustible Gas Detector for Your Application
			
Alarms			
Product
Visible
Audible
Vibrating
STEL
TWA
Honeywell ImpactPro
✔
✔
✔		
✔
MSA Altair 4
✔
✔
✔			
MSA Orion
✔
✔		
✔
✔
MSA Solaris
✔
✔
✔		
✔
MSA Passport PID II
✔
✔		
✔
✔
MSA Sirius
✔
✔		
✔
✔

Data
Infrared
Intrinsically
Logging
Port
Safe
✔			
✔
✔		
✔		
✔
✔
✔
✔
✔			
✔			

Honeywell Impact Pro Multigas Monitor
• Simultaneously monitors and displays readings for O2, CO, H2S, and %LEL
• Three levels of instantaneous alarm, plus time-weighted average alarms
on toxic gases
• Base station combines functionality of data interface and battery charging
• Event and timed data logging
Impact Pro kit includes sensors for CO, O2, H2S, and LEL; integral pump and pump adapter, charger with
charging base, rechargeable NiMH batteries, belt clip, flow adapter, 30' sample tube with inline adapter, ball float,
base station PC link cable, software CD, quick-start guide, user manual, and carrying case.

Honeywell Enforcer Calibrator for Impact Pro
• Calibrates Honeywell Impact Pro multigas monitors fitted with oxygen,
flammable, carbon monoxide, and hydrogen sulfide sensors
• Records calibration results for printing via PC software
• Built-in indicator tells you when gas cylinder needs replacing
• Recognizes Impact Pro immediately, and completes tests and calibration
in less than two minutes
Enforcer kit includes one multigas cylinder, wall-mount plate, and carrying case.

MSA Altair4 Multigas Detector with Pump Probe
• High-contrast LCD shows simultaneous readings for LEL, CO, H2S, and O2
• Ultra-bright LEDs, 95 dB horn, and vibrating alarms for warnings you can't miss!
• MotionAlert signals "man down" by detecting lack of motion for 30 seconds,
InstantAlert lets you sound a manual alarm to warn others of hazards
• 16-hour battery run time when fully charged
Save
20% off the
price
listed purchase ables
rt
po
SA
M
on all
before
when you buy !
12/31/2008

a
Call for pricing onel
od
m
d
se
gently-u

Altair 4 kit includes detector with universal pump probe, sensors for 0-100% Pentane LEL, 0-25% O2, 0-999 ppm CO,
and 0-200 ppm H2S, power supply/charger, MSA-Link software CD-ROM, JetEye infrared adapter with USB connector, user
manual, and carrying case.

Weekly
Rental Price
100.00
125.00
100.00
125.00
250.00
350.00

$40.00
Daily
$100.00
Weekly
$350.00
Monthly
$1304.00
to Buy
$15.00
Daily
$42.00
Weekly
$105.00
Monthly
$268.00
to Buy
$40.00
Daily
$125.00
Weekly
$300.00
Monthly
$1239.00
to Buy

Passport® PID II Personal Organic Vapor Monitor
•
•
•
•
•

Range 0–10,000 ppm with no dilution tube or internal adjustment
Peak, short-term exposure (STEL) and time-weighted average (TWA)
69 pre-programmed and 10 user-defined response factors
Digital display shows numeric and bargraph detail of VOC concentration
5-second access to change battery pack, clean or replace lamp

Passport PID II includes NiCad battery pack, 110 VAC charger, 10' coiled Teflon sampling line, PVC case,
protective rubber boot, pistol grip with wrist strap, and 8" screw-on probe.

$50.00
Daily
$250.00
Weekly
$700.00
Monthly

Save
20% off the
price
listed purchase ables
rt
po
SA
on all M
before
when you buy !
12/31/2008

Lesman Instrument Company
www.lesman.com
sales@lesman.com

Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797

V 10.2008

Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386

COMBUSTIBLE
GAS MONITORS

31

Solaris Multigas Detector for Monitoring Combustible Gases
•
•
•
•
•
•

1-, 2-, 3-, and 4-gas configurations for O2, H2S, CO, and combustibles
100+ dB horn, super-bright LED, and vibrating alarm
Large, easy-to-read alphanumeric digital display
Lightweight unit; IP65 rated for superior protection against liquid/dust ingress
One-button calibration with built-in logic
Lithium Ion battery with runtime of 14+ hours

Kit includes detector, battery charger, charging station, calibration cap, tubing, two male fittings, infrared reader, Solaris
software, quick reference card and manual on CD.

$40.00
Daily
$125.00
Weekly
$300.00
Monthly
$1409.00
to Buy

Sirius Multigas Detector for VOCs and Combustible Gases
• One unit simultaneously monitors VOCs with low vapor pressures and measures
for combustible, toxic, and oxygen-deficient atmospheres
• PID sensor includes humidity resistance, stable zero readings, and fast response
and clear times
• Multidirectional visible LED alarm and audible horn alarm
• Display shows combustible gas, CO, H2S, O2, %LEL, and VOCs with their
character names, also includes battery life indicator
• Interchangeable battery packs keep instrument running 24x7
Sirius kit includes PID lamp, 0-100% LEL, H2S, CO, and O2 sensors, power supply, AC adapter and battery charging unit,
sample line and probe, carrying case, orange Cordura jacket with harness, and instructions.

$100.00
Daily
$350.00
Weekly
$750.00
Monthly
$3617.00
to Buy

Orion™ Multigas Detector for LEL, CO, O2, and H2S
•
•
•
•
•
•
•

One-button calibration simplifies calibration, reduces training needs
Large easy-to-read display for low light conditions and many angles
Long-life durable sensors provide up to 50 times the silicone poison tolerance
Zoom expands any portion of a graph to focus on an activity detail
Software to view gases simultaneously or focus on one at a time
Resistant to water/dust; Nylon case for use in tough environments
Long-life battery provides up to 20 hours in the non-pump mode

Orion kit includes pump module, sensors for %LEL pentane, O2, CO, and H2S, 10' sample line, 1' probe, NiMH battery
pack, battery charger and cord, screwdriver, filters, hose adapter, manual, FiveStar™ Link software, carrying case, orange
Cordura jacket, and integral PulseCheck pump.

$50.00
Daily
$100.00
Weekly
$350.00
Monthly
$2123.00
to Buy

The new RAECO Rents instrumentation
catalog is now available! Get yours FREE!
• 64 pages of instrumentation for industrial hygiene, safety, and
environmental applications
• Rentals available on a daily, weekly, or monthly basis
• All parts, accessories, and software available
• Automatic 5% rental fee discount when you rent online at www.raeco.com
Visit www.raeco.com to request a print catalog or download the free PDF.

WE’RE WAITING!
When you need Honeywell Burner
Controls products fast, call Lesman.
We stock a wide variety of popular items
that can ship to you the same day.

Need a Hand?
Our applications specialists are factory-trained to
help you through the installation and maintenance
headaches of typical flame safety systems.

See More at
Lesman.com
• Full specs and manuals on our burner and
boiler controls product offering
• Lots of articles, technical tips, and
application success stories
• Access to podcasts and video training
• All available 24 hours a day, 7 days a week!

135 Bernice Drive • Bensenville, IL 60106-3366

Use Our Hotlines!
Toll Free
Local Phone
Fax
E-Mail

Bensenville IL

Butler WI

800-953-7626
800-837-1700
630-595-8400
262-923-1790
630-595-2386
262-923-1797
sales@lesman.com wisales@lesman.com

Order by phone, fax, or e-mail for fast, friendly service.
Prices are current as of publication date, and are subject to change without
notice. Visit www.lesman.com/catupdates.html for catalog updates.
Due to contractual agreements with our manufacturers, some items in
this catalog may not be available in all geographic areas or markets.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Instance ID                     : uuid:bc66e151-f113-4c77-b6d1-bf5127433c25
Document ID                     : adobe:docid:indd:fb16ce9a-a6a4-11dd-b597-d5dfe5ef0279
Rendition Class                 : proof:pdf
Derived From Instance ID        : fb16ce99-a6a4-11dd-b597-d5dfe5ef0279
Derived From Document ID        : adobe:docid:indd:fb16ce96-a6a4-11dd-b597-d5dfe5ef0279
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 600.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00
Manifest Placed Y Resolution    : 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 600.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:5C2614C0A73111DD9C10872A98D6DF04, uuid:00F1DD1BA73911DD9C10872A98D6DF04, uuid:5DF43F78D26211DC9615F29052434E54, uuid:E2EADDD7692811DC8520C42567299A1F, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:2F9B5193A09911DAAAD597742AB3E2B6, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:168C6A1139E1DB118BA3BAE9347CE40B, uuid:B2CF4E0AA1C911DD9C10872A98D6DF04, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:90D40D64A75E11DD9C10872A98D6DF04, uuid:CC8EC2365FD611DDABFED848948A8195, uuid:B75CB552D25B11DC9615F29052434E54, uuid:5DF43F78D26211DC9615F29052434E54, uuid:E2EADDD7692811DC8520C42567299A1F, uuid:1C56B7155BD011DDABFED848948A8195, uuid:1C56B7155BD011DDABFED848948A8195, uuid:018C8855692711DC8520C42567299A1F, uuid:04987E05691F11DC8520C42567299A1F, uuid:B8980E9569DB11DC9EB0D24AC369C7DF, uuid:25337F0E5E5911DDABFED848948A8195, uuid:FCC5FD7A692A11DC8520C42567299A1F, uuid:E1923F0D8A5DDD1185F3A556FCBB1714, uuid:FCC5FD82692A11DC8520C42567299A1F, uuid:7D976E925F0B11DDABFED848948A8195, uuid:C7C26AA9A164DD119F33B7C4B6125898, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:DFE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BC490711DDA295E1591AFBB30E, uuid:7073AAF7491611DDA295E1591AFBB30E, uuid:7073AAFE491611DDA295E1591AFBB30E, uuid:BF6C16C65F1711DDABFED848948A8195, uuid:DC4FC983490911DDA295E1591AFBB30E, uuid:DFE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BC490711DDA295E1591AFBB30E, uuid:BF6C16C65F1711DDABFED848948A8195, uuid:7073AAF7491611DDA295E1591AFBB30E, uuid:7073AAFE491611DDA295E1591AFBB30E, uuid:855AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:DC4FC983490911DDA295E1591AFBB30E, uuid:855AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:90D40D64A75E11DD9C10872A98D6DF04, uuid:AC16033275EF11DDB36D85190DDD8BB2, uuid:7DA1CB503875DD11B720DFA8642135E7, uuid:3C7F78A975C511DDB36D85190DDD8BB2, uuid:C10E2F069073DD11AA96AE50A3CCC39E, uuid:F181407075C311DDB36D85190DDD8BB2, uuid:DA41A970BA73DD11AA96AE50A3CCC39E, uuid:A16BEB3D3775DD11B720DFA8642135E7, uuid:DADECDE4691511DC8520C42567299A1F, uuid:04987DFD691F11DC8520C42567299A1F, uuid:E2967103DF46DD1194E8C3AACF87B638, uuid:21E72042692D11DC8520C42567299A1F, uuid:018C8850692711DC8520C42567299A1F, uuid:DAA0EDF269B711DC8520C42567299A1F, uuid:2D9AAF6D617A11DDA42197863AFDB069, uuid:DB344817922711DD8CA5963EBA562DF8, uuid:E40542DA558EDD118B3ED1334A9CAABB, uuid:E0D02CD7A29FDD11975AC1C5DB942EE2, uuid:63C992D2BA9FDD11975AC1C5DB942EE2, uuid:C66744C2A05A11DD9C10872A98D6DF04, uuid:2E04F26C999BDD118C1BD55B4C8FB448, uuid:C66744B9A05A11DD9C10872A98D6DF04, uuid:F232695D789CDD11BE5A991F6EAC47D5, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:51970E36B89BDD11BC25A8384338720B, uuid:F128B4CDC19BDD11BC25A8384338720B, uuid:A581BA1F849CDD11BE5A991F6EAC47D5, uuid:64EDB845999CDD11BE5A991F6EAC47D5, uuid:A76D579A9A9CDD11BE5A991F6EAC47D5, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:F932695D789CDD11BE5A991F6EAC47D5, uuid:C00121F9989CDD11BE5A991F6EAC47D5, uuid:66ABB29C649CDD11BE5A991F6EAC47D5, uuid:BD04C610C89BDD11BC25A8384338720B, uuid:0BAC91DE889CDD11BE5A991F6EAC47D5, uuid:AE6D579A9A9CDD11BE5A991F6EAC47D5, uuid:D45FABE1909CDD11BE5A991F6EAC47D5, uuid:9310C932689CDD11BE5A991F6EAC47D5, uuid:BC0215BB161C11DA8A62BC86F2DA420C, uuid:BAF335E18F5211DA8718BC7171BEF4C4, uuid:0FA6E2728F4A11DA8718BC7171BEF4C4, uuid:0FA6E2778F4A11DA8718BC7171BEF4C4, uuid:81E649048E7911DA8718BC7171BEF4C4, uuid:D6D37C0A161E11DA8A62BC86F2DA420C, uuid:9C9A1A298D91DD11ACFBC9ABC7238363, uuid:0C8219B0156111DAA5A0B8E1861C9D5D, uuid:19CBFB0FD979DD11A6B88BD67EA9365F, uuid:F5DFCBD8E979DD11A6B88BD67EA9365F, uuid:1F19D7BBD279DD11A6B88BD67EA9365F, uuid:1F19D7BBD279DD11A6B88BD67EA9365F, uuid:F5DFCBD8E979DD11A6B88BD67EA9365F, uuid:E52715C0E379DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:E52715C0E379DD11A6B88BD67EA9365F, uuid:5E17A03CF279DD11A6B88BD67EA9365F, uuid:EBDFCBD8E979DD11A6B88BD67EA9365F, uuid:D1AE57018970DD11B3B1CD7DD1EBDF2A, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:53B387B3CF79DD11A6B88BD67EA9365F, uuid:1919D7BBD279DD11A6B88BD67EA9365F, uuid:E7CBEFCE4775DD118543BFBDC6FBEAD1, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:3A9A314366D311DDAE54CA873A8B0032, uuid:A7942BD0A36D11DD9C10872A98D6DF04, uuid:2FF6E1A5ED79DD11A6B88BD67EA9365F, uuid:8F7F306EEF79DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:43169560388EDD119B72CDDEEF182957, uuid:6029C3A4C879DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:C12E988244A111DA96B0C8D23C754193, uuid:0B8A17DE44A211DA96B0C8D23C754193, uuid:E2B5EF19449811DA96B0C8D23C754193, uuid:A52AA190AD2911DAAAD597742AB3E2B6, uuid:6C109C54AD2811DAAAD597742AB3E2B6, uuid:D6D37C12161E11DA8A62BC86F2DA420C, uuid:2F9B5193A09911DAAAD597742AB3E2B6, uuid:E3B06E2D431811DB908DFF8AD8E5CDAE, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:8C75B2BF4A32DD118057E4CEE7FEA81F, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:0899BE434E32DD118057E4CEE7FEA81F, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:168C6A1139E1DB118BA3BAE9347CE40B, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:D50E71DC3637DD11AB79A0FAC0AA5B32, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:A5B340B4B183DB11A056AFDD7106D967, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:1A6FF47CE637DD11A9CB82197BCCD2CE, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:8855672329FB11DBB05FF105C0E59095, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:3A9A314366D311DDAE54CA873A8B0032, uuid:5C2614CAA73111DD9C10872A98D6DF04, uuid:BD3E435AA1B611DD9C10872A98D6DF04, uuid:2EE33897AE48DB11AB63D359F1A4B3E8, uuid:D1AE57018970DD11B3B1CD7DD1EBDF2A, uuid:9A5A10B68A70DD11B3B1CD7DD1EBDF2A, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:A90922738970DD11B3B1CD7DD1EBDF2A
Manifest Reference Document ID  : uuid:A7942BDAA36D11DD9C10872A98D6DF04, uuid:3D16E9D0A73211DD9C10872A98D6DF04, uuid:06AEA9F3D26011DC9615F29052434E54, uuid:E2EADDD6692811DC8520C42567299A1F, uuid:4AFD5D425F1511DDABFED848948A8195, adobe:docid:photoshop:e2ad442e-b40e-11d9-88e0-9b9efc255ea5, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:1868D569FBC0DB1184D8EF70B6C6C624, adobe:docid:indd:459b3107-a1b3-11dd-b597-d5dfe5ef0279, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:dc3476f7-e861-494f-911d-d3370cb14edd, uuid:B75CB551D25B11DC9615F29052434E54, uuid:06AEA9F3D26011DC9615F29052434E54, uuid:E2EADDD6692811DC8520C42567299A1F, uuid:1C56B7145BD011DDABFED848948A8195, uuid:1C56B7145BD011DDABFED848948A8195, uuid:018C8854692711DC8520C42567299A1F, uuid:04987E04691F11DC8520C42567299A1F, uuid:E14AD12A692411DC8520C42567299A1F, uuid:25337F0D5E5911DDABFED848948A8195, uuid:FCC5FD79692A11DC8520C42567299A1F, uuid:E0923F0D8A5DDD1185F3A556FCBB1714, uuid:FCC5FD81692A11DC8520C42567299A1F, uuid:02B818895F0B11DDABFED848948A8195, uuid:C4C26AA9A164DD119F33B7C4B6125898, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:4AFD5D425F1511DDABFED848948A8195, uuid:DEE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BB490711DDA295E1591AFBB30E, uuid:5BF00460691711DC8520C42567299A1F, uuid:8E12E9D7AD47DD11BAF2C95D6B91BBB5, uuid:BF6C16C55F1711DDABFED848948A8195, uuid:DC4FC982490911DDA295E1591AFBB30E, uuid:DEE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BB490711DDA295E1591AFBB30E, uuid:BF6C16C55F1711DDABFED848948A8195, uuid:5BF00460691711DC8520C42567299A1F, uuid:8E12E9D7AD47DD11BAF2C95D6B91BBB5, uuid:845AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:4AFD5D425F1511DDABFED848948A8195, uuid:DC4FC982490911DDA295E1591AFBB30E, uuid:845AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:dc3476f7-e861-494f-911d-d3370cb14edd, uuid:356AABDA3175DD11B720DFA8642135E7, uuid:0B7FD0DB9273DD11AA96AE50A3CCC39E, uuid:C00E2F069073DD11AA96AE50A3CCC39E, uuid:BA0E2F069073DD11AA96AE50A3CCC39E, uuid:D941A970BA73DD11AA96AE50A3CCC39E, uuid:A06BEB3D3775DD11B720DFA8642135E7, uuid:DADECDDE691511DC8520C42567299A1F, uuid:04987DFC691F11DC8520C42567299A1F, uuid:E1967103DF46DD1194E8C3AACF87B638, uuid:21E72041692D11DC8520C42567299A1F, uuid:018C884F692711DC8520C42567299A1F, uuid:DAA0EDF169B711DC8520C42567299A1F, uuid:2D9AAF6C617A11DDA42197863AFDB069, uuid:EAF91A185A8EDD118B3ED1334A9CAABB, uuid:E30542DA558EDD118B3ED1334A9CAABB, uuid:a73d7e14-f605-4d5b-8656-c83acf2ba7f5, uuid:211ecefa-1025-4666-afbf-5be620c471d7, uuid:302e22ae-f859-4945-95d3-24cee3b3df1b, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:32934e88-2113-43d1-bae9-ec562538b6f4, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:eb98d019-bd67-4323-b7fd-35a88157c421, uuid:0d6f44a6-3ba0-44c2-8a36-f81d1880aba0, uuid:5c96255b-a938-4c38-8246-fa64074d2e1c, uuid:d66f0f3f-fad0-4e97-a412-db91b2ff184e, uuid:BC0215BA161C11DA8A62BC86F2DA420C, uuid:BAF335E08F5211DA8718BC7171BEF4C4, uuid:0FA6E2718F4A11DA8718BC7171BEF4C4, uuid:0FA6E2768F4A11DA8718BC7171BEF4C4, uuid:81E649038E7911DA8718BC7171BEF4C4, uuid:BC0215BE161C11DA8A62BC86F2DA420C, uuid:999A1A298D91DD11ACFBC9ABC7238363, uuid:38A02F8A14B911DAA5A0B8E1861C9D5D, uuid:18CBFB0FD979DD11A6B88BD67EA9365F, uuid:F4DFCBD8E979DD11A6B88BD67EA9365F, uuid:1E19D7BBD279DD11A6B88BD67EA9365F, uuid:1E19D7BBD279DD11A6B88BD67EA9365F, uuid:F4DFCBD8E979DD11A6B88BD67EA9365F, uuid:E42715C0E379DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:E42715C0E379DD11A6B88BD67EA9365F, uuid:5D16EC01F279DD11A6B88BD67EA9365F, uuid:EC2715C0E379DD11A6B88BD67EA9365F, uuid:CEAE57018970DD11B3B1CD7DD1EBDF2A, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:52B387B3CF79DD11A6B88BD67EA9365F, uuid:1819D7BBD279DD11A6B88BD67EA9365F, uuid:E6CBEFCE4775DD118543BFBDC6FBEAD1, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, adobe:docid:indd:fb72f998-6074-11dd-9cad-be3a80da5c82, uuid:6BA1B336A27D11DD9C10872A98D6DF04, uuid:7258CA0BED79DD11A6B88BD67EA9365F, uuid:8A7F306EEF79DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:b4828032-9f37-4df0-beaa-19586d86d89d, uuid:5F29C3A4C879DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:C12E988144A111DA96B0C8D23C754193, uuid:0B8A17DD44A211DA96B0C8D23C754193, uuid:E2B5EF18449811DA96B0C8D23C754193, uuid:6C109C57AD2811DAAAD597742AB3E2B6, uuid:D6D37C0D161E11DA8A62BC86F2DA420C, uuid:D6D37C11161E11DA8A62BC86F2DA420C, adobe:docid:photoshop:e2ad442e-b40e-11d9-88e0-9b9efc255ea5, uuid:E3B06E24431811DB908DFF8AD8E5CDAE, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:8B75B2BF4A32DD118057E4CEE7FEA81F, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:a956fcc8-cb86-11dc-aaf4-0016cb381051, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, uuid:1868D569FBC0DB1184D8EF70B6C6C624, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:D40E71DC3637DD11AB79A0FAC0AA5B32, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:A4B340B4B183DB11A056AFDD7106D967, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:indd:ab4ee364-1bd0-11da-a4f9-a9609467894b, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:8855672229FB11DBB05FF105C0E59095, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:indd:fb72f998-6074-11dd-9cad-be3a80da5c82, uuid:5C2614C9A73111DD9C10872A98D6DF04, uuid:BD3E4359A1B611DD9C10872A98D6DF04, uuid:2DE33897AE48DB11AB63D359F1A4B3E8, uuid:CEAE57018970DD11B3B1CD7DD1EBDF2A, uuid:02A24D2E8A70DD11B3B1CD7DD1EBDF2A, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:A60922738970DD11B3B1CD7DD1EBDF2A
Create Date                     : 2008:11:06 08:44:42-06:00
Modify Date                     : 2008:12:30 11:42:22-06:00
Metadata Date                   : 2008:12:30 11:42:22-06:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 22062 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : Lesman "It's On Fire" Combustion Instrumentation Catalog
Description                     : Combustion
Creator                         : Beth Rose, Lesman Instrument Company
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 32
Subject                         : Combustion
Author                          : Beth Rose, Lesman Instrument Company
EXIF Metadata provided by EXIF.tools

Navigation menu