Lesman It's On Fire Combustion Instrumentation Catalog B1048 Cat2008
User Manual: B1048
Open the PDF directly: View PDF .
Page Count: 32
Download | |
Open PDF In Browser | View PDF |
IT’S ON FIRE! With our partners at Honeywell, Maxon, Fireye, and Kromschroder, we can provide you a one-stop source for all your combustion needs. Lesman Chronicle VOLUME BCS-2008 • LESMAN INSTRUMENT COMPANY Seeing Dollar $ign$? WHY GAMBLE? ...Are you willing to risk worker safety for the chance to keep your boiler, furnace, thermal oxidizer, or process heater running? In this day and age, who’s NOT concerned about saving time, energy and money? But where do you start? How about with reduced fuel costs? Or reduced downtime? Did you know... • Mechanical linkages don’t always provide precise fuelair ratio control. • You could be spending 10% to 30% more on fuel than necessary. • You can reduce service and downtime by replacing your mechanical cam and linkage systems. flame safeguard control products let you maximize process availability under safe operating conditions. out For more, check nks™ Li ro Honeywell’s Cont air ratio el fu ss le ge linka on page 10. control system Coming Soon! On-Site Training Take a look inside: From burners and controls, flame detectors, and amplifiers to valves and switches for pressure and temperature, Lesman has the products and the factorytrained staff to help you get the right fit for a finely-tuned combustion system. Need portable monitors for combustion efficiency? We’ve got those, too! Lecture and hands-on sessions taught by our factory-trained product specialist. Classes customized on to focus on your More 3! ge pa specific interests. Flame Safeguard and Burner Control Systems Catalog See Page What’s Inside? Actuators See Page What’s Inside? Pressure Controls Honeywell Modutrol IV Low-Torque Rotary Actuator Motors........................... 13 Honeywell V4055 On-Off Gas Valve Actuator.......................................................... 14 Kromschroder IC20/IC40 Valve Actuators................................................................. 19 Burner Control Systems Fireye BurnerLogix Integrated Burner Management System............................ 19 Fireye Flame Monitor Burner Control System......................................................... 20 Fireye MicroM Flame Safeguard Burner Control System..................................... 18 Fireye MB Industrial Multiburner Flame Safeguard System............................... 21 Honeywell 7800 Series Microprocessor-Based Burner Controls....................4–5 Honeywell ControLinks™ Linkageless Fuel Air Ratio Controls...................10–11 Honeywell RA890 Protectorelay® Electromechanical Primary Control......... 12 Kromschroder Flame Relays and Burner Control Modules.........................22–23 Maxon SMARTFIRE® Intelligent Combustion Control System........................... 15 Flame Detectors and Amplifier Modules Fireye Flame Scanners..................................................................................................... 20 Fireye 65UV5 Integrated Flame Scanner with Internal Flame Relay............... 21 Honeywell R78 Series Flame Signal Amplifiers..........................................................6 Honeywell Flame Detectors........................................................................................8–9 Kromschroder UVS8T Ultraviolet Flame Detector................................................. 23 Industrial Burners Maxon Industrial Burners........................................................................................16–17 © 2008 Lesman Instrument Company Bensenville IL. All Rights Reserved. Honeywell P7810C Pressuretrol® Line Voltage Pressure Controller................ 11 Honeywell C6097 Safety Limit Switches................................................................... 12 Honeywell L404F Pressuretrol® Operating Controls............................................ 12 Kromschroder DG Pressure Switches for Gas Applications................................ 24 Valves ASCO Safety Shutoff Solenoid Valves for Combustion Systems....................... 27 Honeywell V5055 Gas Safety Shutoff Valves............................................................ 14 Honeywell V51E Firing Rate Gas Valves..................................................................... 14 Kromschroder BV Butterfly Valves............................................................................... 25 Kromschroder Valvario® VAS Safety Shutoff Solenoid Valves............................ 26 Maxon Control Valves and Safety Shutoff Valves................................................... 15 Combustion Monitors and Gas Detectors COSA Zircomat In-Situ Stack Gas Oxygen Analyzer.............................................. 28 Testo Combustion Analyzers from RAECO Rents! .................................................. 29 TSI CA-Calc 6213 Combustion Analyzer from RAECO Rents! ............................. 29 Portable Combustible Gas Detectors from RAECO Rents! ...........................30–31 Burner Control Accessories Fireye MicroM Subbase Mounting Adapters........................................................... 18 Honeywell 7800 Series Burner Control Plug-In Modules..................................6–7 Honeywell Q7800 Wiring Subbases...............................................................................5 Due to contractual agreements with our manufacturers, some items in this catalog may not be available in all geographic areas or markets. Prices are current as of publication date, and are subject to change without notice. rner Furnace Typical Single Bu rd System egua with Flame Saf 1. 2. 3. 4. 5. 6. 7. Manual shutoff cock Gas pressure regulator Low pressure interlock Motorized gas valve manual reset Control valve operator High gas pressure interlock Test cock 8. 9. 10. 11. 12. 13. 14. Pilot gas cock Pilot pressure regulator Pilot solenoid valve Gas pilot burner assembly Solid-state ignition transformer Flame detector Primary control relay mounting base 15. 16. 17. 18. 19. 20. High limit safety shutdown Thermocouple leadwire Thermocouple sensor Burner valve controller Main gas valve operator (automatic) Vent valve (normally open) Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 IT’S ON FIRE CATALOG 2008 3 rve You Better! Se to es Lin t uc od Pr on sti bu m Co Expanded Dear Friends, de combustion solutions. expanded our product offering to inclu As you can see in this catalog, we’ve ful to bring you products that green”, we thought it would be help ng “goi ut abo hear you that all With matter if you have a thermal y and reduce energy costs. It doesn’t can help improve burner efficienc rove your burner efficiency imp ace, we’ve got products to help furn or kiln er, heat ess proc r, boile oxidizer, the burner, we’ve got your soluoil. No matter how big or how small and use less natural gas or heating tion for energy savings. t all of your insurance flame safety controls to help you mee neither is running a and If it’s safety your interested in, we have , safe isn’t s flare safe. Lighting burners with s. requirements and keep your workers ence re proper startup and shutdown sequ s process without the controls that ensu ialists will make sure that your upgrade e safety” on staff, give us a call. Our spec or flam ple peo know your that ze folks ardi “the jeop have rols er cont If you no long le as flame safety ple safe. Don’t let something as simp meet all codes and keep your peo shut down your process. solutions to reduce NOx and other e teamed up with vendors that have We’v s? gase ” ouse ip in RAECO, enh “gre cing Need to focus on redu you covered. And with our ownersh vative burners and sensors, we’ve got inno ugh Thro s. tant s. pollu rule l EPA enta with environm comply ment stack gas emissions to help you e upgrades we can even help measure and docu rol systems. So, if you’d like to do som cont er burn or ty safe e flam nt leme imp years of you have help ners to let us know. Our part We even have the expertise or expertise, just give us a call and time the er eith have ’t don . but s, nally cost to save energy safely and professio e, maximize your uptime, and do it ace or boiler experience and can minimize downtim e’s no need for an unplanned furn Ther g. acin old controls that need repl so give us ple, your by peo ing your walk and you keep for ldn’t best is shou You simply don’t work. Being safe rols cont old your use beca pen hap “relocation” that can ng. a call and we’ll help you start upgradi Sincerely, Watch our website for even more helpful tips and product information on flame safety and burner control products. Mike DeLacluyse Combustion Systems Training At Lesman, our goal is to make sure you get the right product, understand how it works, make sure it’s installed properly, and get the most out of it. To help you with that, we’ve created a set of classes to teach you what you need to know about combustion systems, burner controls, and flame safety. Courses are done in a lecture style with question/answer periods. Where necessary, they include some hands on examples. Classes can be held at your plant or in a Lesman Training Center, and can be customized to meet your needs. Here’s a sample of what you can expect from our Lesman U course on combustion. p Lesson 1: When is Flame Safety Required? • Types of applications • Basics of flame detection • Introduction to basic burner systems and terminology • Main functions of flame safety controls • A fully implemented burner system p Lesson 2: Burner Controls • Four categories: Flame switches, primary controls, programmers, microprocessor control systems • Functions of flame safety systems: System checks, burner system sequencing, supervisory functions and shutdown p Lesson 3: Advanced Flame Safety Control Programmers • System components • System functions and applications p Lesson 4: Advanced Flame Safety Concepts • Valve proving systems • Linkageless control systems (Honeywell ControLinks™) • Energy savings with pulse firing p Lesson 5: Gas Trains and Valves Meet Dan... Dan Weise,Lesman product specialist, instructs our customers on process instrumentation theory, hardware and software. Dan’s recent courses have included Honeywell UDC controllers, Trendview and X-Series paperless recorders, and Siemens SIMATIC PDM HART software. Other course curricula include basics of instrumentation (temperature, pressure, level, and flow) and basics of Modbus protocol. Dan has been involved in all facets of data acquisition and process instrumentation, from sales and commissioning to service and product support since 1978. He’s a long-time member of ISA, and has been with Lesman since 1988. In his words, Dan is the guy “who reads all the manuals nobody else reads.”In our customers’words,he’s the trainer to call if you want to “cut to the SO WHAT of instrumentation,” so it’s easy to understand. Call 800-953-7626 to schedule your Lesman U combustion training! BURNER CONTROLS V 10.2008 4 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Microprocessor-Based Burner Controls Choosing the Right Honeywell 7800 Series Burner Control Model RM7840 RM7890 RM7895 RM7898 Control Type Programming On-Off Primary On-Off Primary On-Off Primary Added Function Selectable Pre-Purge Timing, Air Flow Check Units Available with Valve Proving (VPS) Selectable Pre-Purge Timing Selectable Pre-Purge Timing, Shutter Drive, Programmable Post-Purge, Valve Proving Required Components Q7800 Wiring Subbase R78 Flame Signal Amplifier ST7800 Purge Timer Card S7800A1142 Keyboard Display (for VPS) Q7800 Wiring Subbase R78 Flame Signal Amplifier S7800A1142 Keyboard Display (for VPS) Q7800 Wiring Subbase R78 Flame Signal Amplifier ST7800 Purge Timer Card Q7800 Wiring Subbase R78 Flame Signal Amplifier ST7800 Plug-In Purge Timer Card, S7800A1142 Keyboard Display (for VPS) RM7840 Programming Control Unit for Forced-Air Burners Programming control with valve proving for automatically fired gas-, oil-, coal-, or combination fuel single-burner applications. • • • • • Interrupted pilot type Airflow check feature Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity Five LEDs provide sequence information. Power LED blinks fault code on Lockout. CSA, FM, and UL approved Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier, ST7800A plug-in purge timer cards, S7800A1142 keyboard display module for advanced diagnostics, and to set up valve proving Model Selection Guide Flame Establishing Period Pilot Main Interlocks 4 or 10 seconds 10, 15, or 30 seconds, or intermittent Running and low-fire (LHL-LF) 4 or 10 seconds 10 or 15 seconds Lockout, low-fire and high-fire (LHL-LF&HF) Catalog Number RM7840G1022 RM7840L1075 Price $1805.30 2150.57 RM7890 On-Off Primary Control Unit for Forced-Air Burners Microprocessor-based integrated primary burner control for automatically fired gas, oil, coal, or combination fuel single burner applications. • Five LEDs for sequence information • Closed loop logic test, expanded safe-start check, internal hardware status monitoring and tamper-resistant timing and logic • Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity • Selectable recycle/lockout on loss of flame • UL, CSA, FM, FCC approved Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier, S7800A1142 keyboard display module (shown) for advanced diagnostics and to set up valve proving Model Selection Guide Flame Establishing Period Pilot Main 4 or 10 seconds Intermittent 4 or 10 seconds Intermittent 4 or 10 seconds Intermittent 4 or 10 seconds Intermittent Pilot Type Special Features Intermittent Intermittent Shutter Drive Capability Intermittent Valve Proving (VPS) Check Feature, Blinking LED Fault Annunciation Intermittent Shutter Drive Capability, VPS Check, Blinking LED Fault Annunciation Catalog Number RM7890A1015 RM7890B1014 RM7890A1056 RM7890B1048 Price $482.49 506.27 435.25 432.90 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 BURNER CONTROLS 5 RM7895 On-Off Primary Control Unit for Forced-Air Burners Microprocessor-based integrated primary burner control for automatically fired gas, oil, or combination fuel single burner applications. • • • • • On/off primary control with prepurge Five LEDs for sequence information Airflow switch check Selectable relight or lockout on loss of flame Optional local or remote annunciation of operation and fault information, remote reset capability Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier, ST7800 plug-in purge timer card Model Selection Guide Flame Establishing Period Pilot Main 4 or 10 seconds Intermittent 4 or 10 seconds Intermittent 4 or 10 seconds 10 Seconds Pilot Type Airflow Check Intermittent No Intermittent Dynamic Interrupted Dynamic Delayed Main Valve Interlocks No Selectable No Selectable Yes Selectable Catalog Number RM7895A1014 RM7895B1013 RM7895D1011 Price $643.51 643.51 832.29 RM7898 On-Off Primary Control Unit with Valve Proving Microprocessor-based integrated primary burner control for automatically fired gas, oil, or combination fuel single burner applications. • • • • • • On/off primary control Programmable post purge and valve proving feature available through keyboard display module Five LEDs for sequence information, power LED blinks fault code on safety shutdown Airflow switch check and shutter drive output Selectable recycle or lockout on loss of airflow or flame Local or remote annunciation of operation and fault information Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier, ST7800 plug-in purge timer card, S7800A1142 keyboard display module Model Selection Guide Flame Establishing Period Pilot Main 4 or 10 seconds Intermittent or 10 seconds Pilot Type Special Features Selectable Shutter drive output, programmable post purge, valve proving Catalog Number RM7898A1000 Price $569.44 Q7800A or B Wiring Subbases for RM7800 Burner Controls Select either the panel-mount or burner-mount version of the Z7800A,B 22-terminal universal wiring subbase to accommodate your 7800 series relay module. Both are fully compatible with all relay modules, to let you specify a wiring termination approach that meets your application requirements. Model Selection Guide Catalog Description Number 22 Terminal Universal Wiring Subbase Panel Mount Q7800A1005 Burner/Wall Mount Q7800B1003 Price $36.56 36.56 Learn more about Honeywell burner controls and flame safeguard products online at www.lesman.com Download specification datasheets, installation instructions, wiring diagrams and more. Most products available to buy through our secure online store. FLAME SAFEGUARD V 10.2008 6 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 R78 Series Flame Signal Amplifier Modules • Flame signal strength 0.0 to 5.0 VDC • Test jacks measure amplifier signal voltage • Dynamic Ampli-Check™ or Self-Check rectification available, with safety shutdown on amplifier or system failure • UL, CSA, FM approved Solid-state flame signal amplifiers detect the presence of flame in response to a signal from a rectifying, ultraviolet, or infrared flame detector. Dynamic Ampli-Check™ circuitry tests flame amplifier during burner operation; 7800 series relay module locks out on safety shutdown with amplifier failure. Dynamic Self-Check Rectification Amplifier and Dynamic Self-Check Ultraviolet Amplifier test electronic components in the flame detection system 10 to 12 times per minute. The 7800 series relay module locks out on safety shutdown with flame detection system failure. R7849A flame detectors should be used only on burners that cycle on and off at least once every 24 hours. Appliances with burners that remain on for 24 hours or longer should use ultra violet flame detection systems (C7012E/F detector and R7847C amplifier or C7076A detector and R7886A amplifier). Model Selection Guide Color Flame Failure Self- Code Type Response Time Checking Compatible Flame Sensors Rectification-Type Flame Amplifiers, Green Green Rectification 3.0 Seconds Dynamic C7024E, F Flame Detector Green Rectification 0.8 or 1.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 Green Rectification 2.0 or 3.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179; Gas, Oil and Coal: Ultraviolet Flame Sensors C7012A, C Green Rectification 0.8 or 1.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* Green Rectification 2.0 or 3.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* Gas, Oil, and Coal: Ultraviolet Flame Sensors C012A, C Green Rectification 0.8 or 1.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 Green Rectification 2.0 or 3.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C Green Rectification 0.8 or 1.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* Green Rectification 2.0 or 3.0 Second Dynamic Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012E, F Infrared-Type Flame Signal Amplifier, Red Red Infrared 2.0 or 3.0 Second Standard Red Infrared 2.0 or 3.0 Second Ampli-Check Ultraviolet-Type Flame Signal Amplifier, Purple Purple UV 0.8 or 1.0 Second Standard Purple UV 2.0 or 3.0 Second Standard Purple UV 0.8 or 1.0 Second Ampli-Check Purple UV 2.0 or 3.0 Second Ampli-Check Ultraviolet-Type Flame Signal Amplifier, Purple Purple UV 2.0 or 3.0 Second Dynamic Purple UV 0.8 or 1.0 Second Dynamic Catalog Number Price R7824C1002 R7847A1025 R7847A1033 $605.36 241.51 241.51 R7847A1074 R7847A1082 241.51 241.51 R7847B1023 R7847B1031 693.71 693.71 R7847B1064 R7847C1005 693.71 548.49 Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 R7848A1008 R7848B1006 453.29 483.97 Gas, Oil: Minipeeper C7027A, C7035A, C7044 Gas, Oil: Minipeeper C7027A, C7035A, C7044 Gas, Oil: Minipeeper C7027A, C7035A, C7044 Gas, Oil: Minipeeper C7027A, C7035A, C7044 R7849A1015 R7849A1023 R7849B1013 R7849B1021 241.51 241.51 377.08 377.08 Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 R7861A1026 R7861A1034 635.99 635.99 * Leadwire runs greater than 50 ft. ST7800A Plug-In Purge Timer Cards mer card Don’t see the llti Lesman. you need? Ca Purge timers let you purge unburned fuels from the combustion chamber. The plug-in cards install easily into the 7800 series relay module. They are available in 15 timing ranges from 2 seconds to 30 minutes. • Compatible with selected 7800 series relay modules. • CSA, FM approved, UL recognized Model Selection Guide Catalog Description Number 2-Second Pre-Purge ST7800A1005 7-Second Pre-Purge ST7800A1013 10-Second Pre-Purge ST7800A1021 Price $67.88 67.88 67.88 Catalog Description Number 30-Second Pre-Purge ST7800A1039 60-Second Pre-Purge ST7800A1054 1.5-Minute Pre-Purge ST7800A1062 Price $67.88 67.88 67.88 Catalog Description Number 2.5-Minute Pre-Purge ST7800A1070 4-Minute Pre-Purge ST7800A1088 6-Minute Pre-Purge ST7800A1096 Price $67.88 67.88 67.88 Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 www.lesman.com sales@lesman.com V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 FLAME SAFEGUARD 7 Burner Control Plug-In Accessory Modules S7800A1142 Universal Keyboard Display Module Provides current status of burner sequence, timing, hold, and lockout information plus selective or preemptive messages. Required for programming Valve Proving and Post Purge features on 7800 series relay modules. • First-out annunciation and system diagnostics provided in 2-row by 20-column display • Provides burner control data, remote reset, and report generation • Local or remote operation, fault information Model Selection Guide • UL listed, CSA certified, FM approved, and FCC rated Description Universal Keyboard Display Catalog Number Price S7800A1142 $485.61 S7810A1009 Data ControlBus Module S7820A1007 Remote Reset Module Lets you connect a remote reset switch, a remote keyboard display module, or communicate to a personal computer. Links a remote reset switch (push-button) that allows the 7800 series burner control to be reset from a remote location. • Installs directly on front of 7800 relay modules • Communications interface, remote reset • Use with remote mounted keyboard display • Installs directly on front of 7800 relay module • Allows reset of 7800 series relay module by a remote reset push-button up to 1000 feet away Model Selection Guide Model Selection Guide Description Remote Mounting of Keyboard Display Module PC Interface, and Remote Reset Function Catalog Number S7810A1009 Price $206.64 Description Remote Module for Resetting 7800 Series Relay Module Catalog Number S7820A1007 Price $228.75 S7830A1005 First-Out Expanded Annunciator Panel Monitors the status of a series string of limit, control, and interlock contacts. It enhances fault and status messages of the 7800 series burner control. • 26 LEDs — 22 LEDs to annunciate limits and interlocks, 4 LEDs to annunciate power, current status, first-out status, and system lockout • Enhances keyboard display module sequence hold Model Selection Guide and lockout messages Catalog • Connects to 7800 series relay module via RS485 Description Number Price • UL listed, CSA, FM approved First-Out Expanded Annunciator S7830A1005 $935.07 Connector for Keyboard Display 203541 45.30 Hey Lesman... Where’s My Stuff? well Buy your Honey and burner controls ucts od pr d flame safeguar an r fo at Lesman.com s! ng vi instant 15% sa Want to know when your Lesman order will arrive? Use the Order Status checker, right on the Lesman.com homepage! • Enter your PO number and 5-digit zip code, and click the “Check Status” button. We’ll show your order details and a clickable tracking link at UPS or FedEx. If the order hasn’t shipped, it’ll give you the expected ship date. FLAME DETECTORS V 10.2008 8 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Flame Detectors Model C7008, C7009 Q340A C7012 Purple Peeper® C7027 Minipeeper® C7035 Minipeeper® C7061 Purple Peeper® C7076 Detector Type Flame Rod Thermocouple Rectification Ultraviolet Ultraviolet Ultraviolet Ultraviolet Ultraviolet Burner Type Gas-Fired Gas-Fired Coal, Gas, or OilFired Coal, Gas, or OilFired Coal, Gas, or OilFired Gas or Oil-Fired Gas or Oil-Fired Pilot Type Intermittent or Standing Intermittent or Standing Intermittent or Interrupted Intermittent or Interrupted Intermittent or Interrupted Intermittent or Interrupted Intermittent or Interrupted Unique Feature 100% Fail-Safe Operation Low Cost Units for Process Applications Dynamic Self-Check, Shutter 1/2” Sight Pipe Mount 1” Sight Pipe Mount Dynamic Self-Check Dynamic Self-Check, Adjustable Sensitivity Flame Amplifier R7247A,B, R7847A, B, R7257, R7289 Typically Connected via UDC R7247C, R7847C, R7747C R7249A,B, R7849A, B, R7749B, R7259, R7290 R7249A,B R7849A,B R7749B, R7259, R7290 R7861 R7476A1015, R7886A1001 C7008, C7009 Rectification Flame Rods Kantal A-1 flame rod with sparkplug-type rod holder, threaded base, and snap-on cover. 100% fail-safe flame detection. For use with gas-fired systems and intermittent pilots only. Use with Honeywell flame safeguard controls that require rectification-type flame detectors. Can be used with or without cover and cut to desired length. Includes flame rod holder and Rajah electrical connector. Approvals: UL, CSA, FM. Model Selection Guide Flame Rod Holder Dimensions Length Length Diameter 12” 3-3/4” 7/8” 24” 3-3/4” 7/8” 4” 2-3/8” 3/8” 12” 2-3/8” 3/8” Electrical Connection 1/4” NPT Male 1/4” NPT Male 1/8” NPT Male 1/8” NPT Male Catalog Number C7008A1174 C7008A1182 C7009A1009 C7009A1025 Price $166.01 246.46 103.84 135.98 Q340 Thermocouples for Gas-Fired Pilot Flame Detection Premium long-life, durable 30mv thermocouples generate a thermoelectric current that senses a pilot flame on gas-fired heating systems. For easy installation, the Q340A comes with a push-in clip, split nut, and an adapter assembly, plus a 11/32 male connector nut for Pilotstat® safety control power units. Model Selection Guide Output: Normal: 26 to 32 mV; Lowest Acceptable: 18 mV; Turndown: 2 mV Temperature Rating: 1400°F at hot junction, 780°F at cold junction Replacement for: Robertshaw 1980, T45, T46, White Rogers HO series, Penn-Baso K15, K16, K19, 88D, ITT-General 2500 and 2600 series, and Jade TK5 Catalog Lead Length Number 36” (914mm) Q340A1090 48” (1219mm) Q340A1108 C7076 UV Detector with Adjustable Sensitivity Dual adjustable sensitivity with 400:1 dynamic range, for use with intermittent or interrupted pilots on gas- or oil-fired burners. Compatible with R7476A and R7886A dynamic selfcheck UV flame amplifiers. Closed-loop self-checking circuit ensures integrity of both amplifier and flame detector. Price 10.72 11.92 an.com Visit www.lesm els. od m r la for popu our h ug ro th Buy online ore! secure online st Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 FLAME DETECTORS Available soon! UV/IR flame detectors from IRIS Systems. Call Lesman for details. C7012 Purple Peeper® Solid-State UV Flame Detectors Solid-state UV flame detector with dynamic self-check, for coal-, gas-, or oil-fired burners. Can be used with intermittent or interrupted pilots. Compatible with R7247C, R7847C, and R7747C UV flame amplifiers on Honeywell RM7800 series relay modules. Mounts horizontally, vertically, or at any angle in between. Provides quick electrical hookup with threaded conduit fitting and color-coded leadwires. Reduces nuisance shutdowns by wiring two in parallel. Mounting: Mounting flange with NPT internal threads for attaching to sight pipe Approvals: UL, CSA, FM. Model Selection Guide Catalog Description Number Price Dynamic Self-Checking Ultraviolet Detector 120 VAC, 3/4” NPT C7012E1104 $3161.29 120 VAC, 1” NPT C7012E1112 3161.29 C7027 Minipeeper® Ultraviolet Flame Detectors Compact UV flame detectors for use on coal-, gas-, oil-fired or combination burners. Can be used with either intermittent or interrupted pilots. Compatible with R7248A/B, R7849A/B, R7749B, R7259, and R7290 solid-state UV flame amplifiers on Honeywell RM7800 series relay modules and controls. Model Selection Guide Compact size allows for blast-tube mounting. Seals against pressures up to 5 psi when correctly installed. Wire in parallel for difficult sighting applications. Mounting: 1/2” sight pipe with integral collar or 1/2” NPT threaded spud connector. Dimensions: 1-1/8” diameter (with mounting nut), 3-7/8” length, 8-foot lead. Electrical Connections: Two NEC Class 1 leadwires Approvals: UL, CSA, FM. Ambient Sight Pipe Catalog Temp. Range Mounting Number Price -40° to 215°F Integral nut C7027A1031 $166.75 -40° to 215°F Integral nut* C7027A1072 166.75 0° to 215°F Integral nut C7027A1023 150.41 0° to 215°F Integral nut* C7027A1049 150.41 0° to 215°F Integral nut** C7027A1080 186.95 * 1/2” NPT threaded spud connector ** Includes 136733 heat block and 390427B bushing C7035 Minipeeper® Ultraviolet Flame Detectors Compact ultraviolet flame detectors with field-replaceable UV sensing tubes. For use on coal-, gas-, oil-fired or combination burners. Can be used with either intermittent or interrupted pilots. Compatible with R7248A/B, R7849A/B, R7749B, R7259, and R7290 solid-state UV flame amplifiers on Honeywell RM7800 series relay modules and controls. C7035 Shield protects sensing tube. Seals against pressures up to 5 psi when correctly installed. Can be wired in parallel for difficult sighting applications. Mounting: 1” sight pipe with integral collar Dimensions: 1-1/2” diam. (with collar), 4-1/8” length, 72” leads Approvals: UL, CSA, FM. Model Selection Guide Catalog Description Number 0° to 215°F temperature range, 6’ lead C7035A1023 Replacement UV sensing tube for C7035 129464M 129464M Price $330.90 301.68 C7061 Purple Peeper® Solid-State UV Flame Detectors Ultraviolet flame detector with dynamic self-check for gas-, or oil-fired burners. Can be used with intermittent or interrupted pilots. Compatible with R7861 dynamic self-check UV flame amplifiers on Honeywell RM7800 series relay modules. Model Selection Guide Mounts horizontally, vertically, or at any angle in between. Reduces nuisance shutdowns by wiring two in parallel. Fieldreplaceable UV sensing tube and quartz viewing window. Mounting: Mounting flange with 3/4” NPT internal threads Dimensions: 5-1/4” diam. (with flange), 7-7/32” long, 96” leads Approvals: UL, CSA, FM. Catalog Description Number 120 VAC, 3/4” NPT C7061A1012 120 VAC, 3/4” NPT* C7061A1038 UV Sensing Tube 129464N * With Brad Harrison 41310 connector Price $1377.66 1398.48 335.68 129464N 9 FUEL AIR RATIO CONTROL V 10.2008 10 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 ControLinks™ Fuel Air Ratio Control System Honeywell ControLinks™ fuel air ratio control system helps you realize energy savings, increased turndown, reduced emissions, and system reliability in an easy-to-install, powerful, and cost-effective package. Features • Stand-alone parallel positioning control system designed for easy retrofit • Dynamic safety checks: failsafe potentiometer check, anti-swap of actuators, and curve verification algorithms, relay test for limit control input/ output (LCI-LCO) contact set • Integrated shock protection algorithms: Water or stack temperature low fire hold, flue gas recirculation (FGR) hold, FGR and low-fire hold • Controller LEDs: Power, alarm, motor 1, 2, 3, 4 for status, and fault code annunciation (60 possible) • Two independent fuel profiles with or without FGR • Programmable positioning for non-selected fuel actuator, standby, purge, light-off, or minimum/ maximum modulation • Up to four universal parallel positioning actuators: Combustion air, fuel 1, fuel 2, FGR/flexible usage • Fourth channel actuator flexible usage: FR, secondary air control, secondary modulating fuel valve • Auto/manual firing rate input • Seven to 24 points per profile curve with quick setup feature, providing minimum three-point profile curve • Actuator CW/CCW switches for manually driving hub —useful for installation and service • Actuator LED annunciation for unconfigured, configured, on-line, or faulty actuator states Typical boiler application with Honeywell ControLinks™ fuel ratio control system installed. Honeywell ControLinks™ replaces the traditional single point modulation of a mechanical cam-and-linkage assembly that controls the relationship between fuel, airflow, and flue gas recirculation on a power burner. The linkageless fuel air ratio control provides more accuracy and efficiency in actuator positioning and burner firing, reducing your service requirements and downtime. It can be installed as part of a retrofit or a new burner application —anywhere increased efficiency is desired. Up to four independently controlled universal parallel positioning actuators (UPPAs) are managed by the ControLinks controller, which responds to load and firing rate demands. ControLinks can be used on single or combination fuel single burner applications, including power burners, boilers, process furnaces, ovens, smelting, kilns, paint drying booths, VOC burn-off, ceramics, make-up air heaters, or any full modulating burner. R7999A ControLinks™ Fuel Air Controller Uses the latest microprocessor technology to simultaneously control up to four actuators. Use with ML7999 actuators to replace mechanical cam-and-linkage assembly controlling the relationship between fuel, airflow, and flue gas recirculation (FGR) on a power burner. Fast burner setup vial PC or laptop. Two independent fuel profiles with or without FGR. Programmable behaviors of all actuators during purge and standby. Programmable behavior of non-selected fuel actuator. Independent light off and minimum modulation positions. Auto/manual input and manual mode firing-rate input. Multipurpose communications port. ZM7999A ControLinks™ configuration software tool lets you create burner modulation curves (profiles) for your burners, for safe and efficient operation at all points along the curve. Wizards step you through the commissioning process. Save files on your PC to use over again. Complete System Requires: R7999 controller, Q7999 wiring subbase, ML7999 positioning actuator, and ZM7999 configuration software. Model Selection Guide Catalog Description Number Fuel air ratio controller, 100-120 VAC, 50/60 Hz R7999A1005 Field wiring terminal subbase for R7999A controller. Panel mount, NEMA 1 enclosure Q7999A1006 ControLinks™ Windows-based configuration software for R7999A controllers ZM7999A1006 Price $774.90 98.53 365.93 line at Learn more on.c om! an m es www.l Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 FUEL AIR RATIO CONTROL 11 ML7999 Universal Parallel-Positioning Actuators ControLinks™ actuators control the position of primary and secondary fuel valves, combustion air damper, and flue gas return dampers. UL, CSA, CE approved. Vibration: 0.0 to 0.5g continuous Environmental Conditions: Ambient Temperature: -40° to 140°F; Operating Temperature: -40° to 150°F; Operating Humidity: 5% to 95% RH, non-condensing Model Selection Guide Call for adapter assemblies for connecting to shaft sizes other than 1/2”. Catalog Actuator Description and Function Number Pulse-width modulating control of combustion air dampers, butterfly gas valves, oil ML7999A2001 modulation valves, and flue gas recirculation systems. Includes precise feedback potentiometer and integral power supply. Parallel-positioning actuator. Provides 4-20 mA control input to control combustion air dampers and modulation ML7999B1002 valves. Includes precision drive shaft control and integral power supply capable of direct line voltage connection. Direct coupled actuator. Price $272.80 540.84 S7999B ControLinks™ Configuration Display Monitor up to 99 burner systems connected via Modbus. Each burner control, fuel/air ratio control, expanded annunciator or other Modbus devices present on the burner system can be viewed individually to determine its status. Display: Color 3.5” x 4.6” touchscreen interface with screen saver, contrast and volume controls Communications: Two RS485 Modbus ports for monitoring up to 99 unique controls Function: Allows setup and monitoring of R7999 ControLinks controller, programmable expanded annunciator terminal remaining, and R7999 EEPROM backup and restore Model Selection Guide Catalog Description Number Touchscreen display for ControLinks™ system. 12 VDC input power S7999B1000 Price $1193.07 P7810C Pressuretrol® Controller Line voltage pressure controller that eliminates the need for a controller and transmitter. One unit does on/off control, high limit and 4-20 mA modulation. Accuracy: ±4.0% full scale output over operating temperature (32° to 140°F) Model Selection Guide Description Solid State Pressuretrol® Controller with On/Off Control, Limit Control, 0–15 PSI and 4-20 mA Modulation. FM, CSA, UL Approvals. 0–150 PSI LED Indicators for Power, Call for Heat Function, and Lockout Status 0–300 PSI Siphon Loop with 1/4” NPT Threads for P7810C ControLinks™ Accessories Looking for a ion st portable combu ? er analyz See page 29. lable Handhelds avai nt! re or le sa for Catalog Number P7810C1000 P7810C1018 P7810C1026 209731A Price $524.81 583.72 651.85 32.61 Catalog Number 201391 32002935-001 32003168-001 32003168-002 32003168-003 32003396-001 32003396-002 32002515-001 Price $3.23 18.56 44.22 50.07 50.07 43.48 47.34 9.53 Model Selection Guide Description ML7999 actuator shaft adapter for and 3/8” round or square valve shaft ML7999 actuator weatherproofing kit (1 corner stop, 2 gaskets) ML7999 actuator 3/4” shaft adapter assembly ML7999 actuator 5/8” shaft adapter assembly ML7999 actuator 9/16 shaft adapter assembly V51E mounting plate for 1.5” and 2” valves V51E mounting plate for 2.5” 3”, and 4” valves R7999 3-pin electrical connector BURNER CONTROLS V 10.2008 12 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Mechanical Burner Controls and Safety Switches C6097 Safety Limit Switches Limit switches for positive or differential pressure systems to sense natural gas, liquid propane gas, or air. Removable clear protects scaleplate and adjusting knob. Temperature Range: -40° to 140°F Switch Ratings: 3.0 AFL, 18.0 ALR, 5.0 Amp resistive. Can be wired to turn on alarms. Model Selection Guide Operating Pressure Differential at Switch Catalog Range Min. Setpoint Max. Setpoint Operation Mounting Number Diaphragm-Actuated Safety Limit Switch, Brake on Pressure Fall, 1/8” NPT Internal Threaded Connection 0.4” to 5” WC 0.6” WC 0.25” WC Manual Reset 1/4” NPT C6097A1095 3” to 21” WC — — Auto Recycle 1/4” NPT C6097A1053 Diaphragm-Actuated Safety Limit Switch, Break on Pressure Rise, 1/8” NPT Internal Threaded Connection 12” to 60 “ WC 10” WC 12” WC Manual Reset 1/4” NPT C6097B1002 1.5 to 7 PSI 1.1” WC 1.4” WC Manual Reset 1/4” NPT C6097B1051 Price $117.40 96.26 124.96 136.22 L404F Pressuretrol® Controllers Operating control with automatic limit protection for pressure systems. Use with steam, air, noncombustible gases, or fluids non-corrosive to pressure sensing element Switching Action: SPDT snap-action switch to open or close a circuit on pressure rise Connections: Pipe (main or high pressure): 1/4” NPT internal thread; Electrical: Screw terminals Model Selection Guide Operating Range 2 to 15 PSI 5 to 50 PSI 10 to 150 PSI Sustained Pressure 25 PSI max. 85 PSI max. 225 PSI max. Adjustable Differential 2 to 6 PSI 6 to 14 PSI 10 to 22 PSI Sensor Element Stainless Steel Diaphragm Stainless Steel Diaphragm Stainless Steel Diaphragm Unit Includes Siphon Loop Ground Screw — Catalog Number L404F1060 L404F1375 L404F1102 Price $172.29 175.01 192.05 RA890 Protectorelay® Electromechanical Primary Control Non-programming primary control provides flame safeguard protection for industrial and commercial single or dual fuel burners. With SPDT alarm contacts. Use with flame rods, rectifying photocells and C7012A,C Purple Peeper ultraviolet flame detectors. Recycles once after failure to reestablish pilot. No start if failure occurs in flame detector circuit. Power Rating: 50 Hz: 8.5w, 17VA max.; 60 Hz: 7w, 13 VA max. Ambient Temperature: -20º to 105°F Approvals: CSA, FM, UL Model Selection Guide Safety Switch Flame Failure Description Timing Response* Rectification-Type 15 Seconds 3.0 Seconds Ultraviolet-Type 15 Seconds 3.0 Seconds Q270A Protectorelay® Mounting Subbase Catalog Number RA890F1288 RA890G1260 Q270A1024 Price Each $1385.97 1385.94 116.04 Compatible flame detectors on pages 8–9. S8610U3009 Intermittent Pilot Ignition Control Provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot ignition systems used on natural or LP gas-fired furnaces, boilers, and heating applications. Model Selection Guide Electrical Rating: 24 V, 60 Hz; Current Draw: 1A pilot valve, 2A main valve; Contact Rating: 0.2A Field Replacement: For most Honeywell, Robertshaw, Johnson, UTEC (HCS) intermittent pilot ignition modules Description Intermittent pilot control. 15- or 90-sec trial for ignition, 0- or 30-sec configurable pre-purge Catalog Number Price S8610U3009 $164.37 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 ACTUATOR CONTROLS 13 Low-Torque Rotary Actuator Motors Modutrol IV Low torque, light duty, rotary action Modutrol IV motor is designed for accurate positioning of dampers and valves in industrial ovens, furnaces, and process heaters. Torque Rating: 25 to 300 Lb-In Timing: 15 to 240 seconds Stroke: Fixed or adjustable, 90° and 160° dual on some models Limit Switches: Two end-of-travel limit switches standard Approvals: CSA, UL More models available online. Visit www.lesman.com/get/modutrol.php for series specifications, model selection, and part number cross references. Model Selection Guide * Field-addable auxiliary switches Stroke Timing Torque Auxiliary Functional Replacement Catalog 90° 160° Rating Switches Product Includes for These Obsolete Models Number Proportional-Reversing Motors, 135 Ohm Input Signal, 90° to 160° Field-Adjustable Stroke (Unless otherwise specified) 15 sec 30 sec 75 Lb-in 0 M9184D1005 15 sec 30 sec 75 Lb-in 1 Tapped Shaft M9484D1002, D1036, and E1116 M9484E1009 30 sec 60 sec 35 Lb-in 0 Adjustable Zero/ Span, Transformer M8161A1024 and A1032, M9164A1005 M9161A1008, M9164A1021 and A1054 30 sec 60 sec 35 Lb-in 0* M9164A1120, A1062, A1047, and A1096 M9164D1009 30 sec 60 sec 60 Lb-in 0* 24 VAC, Spring Return M7285A1052, M7282A1006, M9185D1004 M9175D1014, D1006, and D1014 30 sec 60 sec 60 Lb-in 1 M9185E1019 30 sec 60 sec 150 Lb-in 0 M9484D1028, D1044, and D1051 M9484D1010 30 sec 60 sec 150 Lb-in 0* M9184A1012, A1035, B1009, B1017, B1025, M9184D1021 M9184D1013, D1047, and D4009 30 sec 60 sec 150 Lb-in 1 M9484E1090 and E4003 M9484E1017 30 sec 60 sec 150 Lb-in 1 Motor Crank Arm, M9484E1025, E1041, E1058, E1066, M9484E1033 Ships in 90° Position M9484E1074, and E1082 30 sec 60 sec 150 Lb-in 2 Ships in 90° Position M9484F1007 30 sec 60 sec 150 Lb-in 2 Tapped Shaft, Ships in 90° Position M9484F1031 30 sec 60 sec 150 Lb-in 2 M9184F1000 and F1018 M9184F1034 30 sec — 35 Lb-in 2 M9184C1031 — 60 sec 60 Lb-in 2 24 VAC, Spring Return M9185C1006 — 60 sec 150 Lb-in 0 M9181A1012, M9184A1001 M9184A1019 Proportional-Reversing Motors, 120 VAC Power, Modulating 4-20 mA Input, Adjustable Zero and Span. Transformer and Screw Terminal Adapter Included 15 sec 30 sec 75 Lb-in 0 M7284A1038 30 sec 60 sec 150 Lb-in 0 M281A1007, M7284A1046 M7284A1004 30 sec 60 sec 150 Lb-in 0 M7284A1020 M7284A1012 30 sec 60 sec 150 Lb-in 2 M7284C1018, M7284C1026 M7284C1000 30 sec 60 sec 150 Lb-in 2 M7284Q1017 M7284Q1009 60 sec 120 sec 300 Lb-in 2 M7294Q1007 Motors with Switched SPDT or Floating Output, 120 VAC Power, SPDT Input, 3-Wire, Line Voltage, or Position Proportional Controller — 30 sec 75 Lb-in 0 M6184A1023 30 sec — 150 Lb-in 0 M6284A1014, A1002, A1048, A1071, and 1063 M6284A1055 Motors with Switched SPDT or Floating Output, 24 VAC Power, 3-Wire, SPDT or Voltage Input 15 sec 30 sec 75 Lb-in 0 Low Voltage M6184D1001 30 sec 60 sec 150 Lb-in 0* Low Voltage M6181A1018, D1004, F1009, F1017, M6184D1035 M6161A1004, M6184A1007 and B1021 30 sec 60 sec 150 Lb-in 2 Line Voltage M6184F1014 Stroke Stroke Torque Auxiliary Functional Replacement Timing (Deg) Rating Switches Product Includes for These Obsolete Models Two-Position Spring Return Motors, SPST, 2-Wire, Voltage Inputs 30 sec 75° 20 Lb-in 1 120 VAC Power M436A1041 A1082, A1090, A1165, and A1181 60 sec 160° 60 Lb-in 0 120 VAC Power 60 sec 160° 60 Lb-in 1 120 VAC Power M4182B1002 30 sec 90° 60 Lb-in 1 120/208/240 VAC M4185B1017 20 sec 45° 30 Oz-In 0 30/60 90/160 60 Lb-in 0* 24 VAC M8185B1000 and B1034 (w/ 220736A) Catalog Number M436A1116 M4185A1001 M4185B1009 M4185B1058 M847A1072 M8185D1006 Price $806.09 965.43 682.92 608.10 905.25 1013.40 822.55 836.50 965.43 954.42 1014.01 1024.93 1008.54 1008.54 1094.20 806.09 984.96 940.89 940.89 1103.17 1103.17 1106.72 606.46 733.15 554.23 544.29 714.91 Price $350.76 554.32 587.40 610.07 123.66 456.87 VALVES AND ACTUATORS V 10.2008 14 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Valves and Actuators V4055 On-Off Gas Valve Actuator Use with Honeywell V5055 gas valves where smooth light off is important to control gas supply to industrial burners. Model Selection Guide One second maximum closing time. Continuous display of valve position with a red (open) or yellow (closed) indicator. Provides final safety shutoff service when used with V5055 valves. Temperature Range: -40° to 150°F Operating Pressure: 5 psi maximum Electrical Rating: 120 VAC, 60 Hz Auxiliary Switch Contact Ratings: 9.8 AFL, 55.8 ALR, 1/2 hp; Proof of Closure Switch Contact Ratings (V4055D): 4.9 AFL, 29.4 ALR, 1/2 hp; 9.8 AFL, 58.8 ALR, 1/2 hp Timing Internal Damper Catalog (Open) Auxiliary Switch Shaft Number Price On-Off Actuator, Use with V5055/V5097A,B Valve Bodies 13 sec Yes (90° Stroke) No V4055A1296 $559.16 No Yes V4055A1098 499.13 13 sec 13 sec No No V4055A1031 499.13 26 sec No Yes V4055A1064 462.11 26 sec No No V4055A1007 462.11 26 sec No No V4055A1312* 976.96 On-Off Actuator with Proof of Closure Switch, Use with V5055C/ V5097C Valve Bodies Yes No 13 sec V4055D1035 600.71 13 sec No Yes V4055D1019 540.65 13 sec No No V4055D1043 540.65 26 sec No Yes V4055D1001 505.95 * NEMA 4 Enclosure V5055 Industrial Gas Safety Shutoff Valve Safety shutoff valves used with V4055 fluid power actuators to control natural or LP gas flow to commercial and industrial burners. Mounts directly in gas supply line. Temperature Range: -40°F to 150°F Includes: 1/4”–18 NPT upstream and downstream taps and plugs Proof of Closure: V5055C valves have double seal and are used with V4055D and V4055E actuators to provide proof-of-closure switch and valve seal over-travel interlock Approvals: FM, CSA, and UL Model Selection Guide Pipe Max Operating Catalog Size Capacity Differential* Functions Number Safety shutoff valves for use with V4055 valve actuators 1.5” NPT 1717 cf/Hr – 48.6 m3/Hr 5 PSI max On/off safety shutoff V5055A1020 2” NPT 3620 cf/Hr – 102.5 m3/Hr 5 PSI max On/off safety shutoff V5055C1000 with double seal 2.5” NPT 4250 cf/Hr – 120 m3/Hr 5 PSI max On/off safety shutoff V5055C1018 with double seal 3” NPT 4250 cf/Hr – 148 m3/Hr 5 PSI max On/off safety shutoff V5055A1053 Price $301.74 731.15 861.65 674.84 * When used with V4055A or D models. 15 PSI when used with V4055B, E, F, or G models. V51E Butterfly Firing Rate Gas Valve Provides modulating control of natural, manufactured, LP gases or air. Use in commercial and industrial instal- Model Selection Guide lations where large amounts of gas must be closely controlled. Do not use as a safety shutoff valve. Use with mod motor and Q100 linkage. Includes strain release. Looking for a mod motor? See page 13. Temperature Range: 32° to 140°F Pressure: Rating: 5 psi max.; Inlet/outlet pressure tapping: Two downstream 1/4” NPT taps Material: Aluminum body Approvals: UL Pipe Size Capacity 1.5” 4200 cf/Hr – 118.9 m3/Hr 2” 9210 cf/Hr – 260.7 m3/Hr 2.5” 8390 cf/Hr – 199.8 m3/Hr 3” 14640 cf/Hr – 414.5 m3/Hr Bracket for 2” valve/Modutrol motor Bracket for 2.5” valve/Modutrol motor Strain release assembly Stop screws for stop bracket (2 reqd.) Linkage kit V51 to M941 Modutrol Catalog Number Price V51E1000 $396.95 V51E1018 448.72 V51E1034 474.85 V51E1059 500.35 127413 169.18 127415 203.18 49085B 214.28 80897BC/0021 2.93 Q100B1006 99.81 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 COMBUSTION CONTROLS 15 MAXON Combustion Control Systems SMARTFIRE® Intelligent Combustion Control System • Precise electronic control of air and fuel flow to the burner to maximize efficiency and minimize emissions simultaneously • Maintains emissions or fuel efficiency over the entire operating range of the burner, not just at one burner setpoint • Automatically compensates for changes in combustion or process conditions with full cross-limited ratio control, maximizing burner performance and ensuring a highly repeatable heat source • Integrates easily with all burner management systems, reducing engineering costs in retrofit applications • Advanced diagnostics and troubleshooting provide real-time information about combustion and process system performance • Remote monitoring gateway option reduces process downtime by providing immediate off-site technical support over a phone line • Redundant system safety checks built into intelligent components significantly reduces the risks associated with combustion system commissioning and maintenance neglect • FM and CSA approved,and meets requirements of European EMC and low-voltage directives Safety Shutoff Valves • Cast iron, carbon steel, low-temp carbon steel, and stainless steel bodies with internal trim options for general purpose or corrosive gases • Unique bonnet design eliminates packing adjustments, reducing maintenance and minimizing drag on closing • Oxygen compatibility available • Meet Fluid Control Institute 70-2 control valve standard for Class VI seat leakage; Full assessment to IEC 61508 as SIL-3 capable Series 5000 Electromechanical Valves • Electrically actuated valves with powerful closing spring, provides closure in <1 second for reliable operation • 3/4” to 6” line sizes, pressures to 125 psig • Field-rotatable top assemblies in 90° increments to fit your application • Actuators available with manual reset or automatic reset operators • Ambient, gas temperatures: -20° to 140°F • Available normally closed or normally open • FM, CSA, UL, and CE approved; Available for non-incendive Class I, Div 2 areas Series 8000 Air-Actuated Valves • Pneumatically actuated valves with powerful closing spring for reliable operation • 3/4” to 6” line sizes, pressures to 255 psig • Compact design with integral solenoid, quick exhaust and position switches that protects components, simplifies piping, and minimizes space needs • Temperature ranges: Ambient: -40° to 140°F; Gas: -40° to 212°F • FM, CSA, and CE approved safety shutoff and vent valves; Available in intrinsically safe and non-incendive constructions for hazardous location use • NACE-compliant trims available information Look for more stion control on Maxon combu and valve s, systems, burner Lesman.com at e lin products on MICRO-RATIO® Flow Control Valves These assemblies are used for air, gas, and oil proportioning control. The multiple screw cam assembly provides mechanical adjustment capabilities to the air/fuel ratio at each valve position throughout the entire capacity range of your burner system. Throttling range is fully adjustable and designed to operate over the wide turndown capabilities of Maxon’s burner systems. Stand-by fuel requirements are simplified by using tandem-linked “air-gas-oil” valves to provide single point control for multiple fuel or multiple zone systems. A complete system using Maxon flow control valves will typically include a burner, gas and/or oil pipe trains,mixing equipment, pressure blower, and a control panel. INDUSTRIAL BURNERS V 10.2008 16 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 www.lesman.com sales@lesman.com Make-Up Air (Food or Spray Dryers, Food Processing) √ Oxidizers Paper Mill Dryers Pre-Heated Combustion Air √ √ √ √ Rotary Dryers and Kilns Solution Heating and Finishing Systems √ √ √ √ • Nozzle-mixing line burner for use with low pressure natural gas, propane and butane • Single-piece aluminum extrusion body design eliminates leakage • Cooler oven walls due to deeper penetration inside the oven (wallmount); Independent of variable process air flows (in-duct) • Corrosion-resistant main gas/air body and durable stainless steel mixing plates • Up to 1.0 MMBtu/h per foot; Up to 40:1 turndown • Packaged units up to 15 foot in length NP-LE AIRFLO® • Designed for direct-fired make-up air and process applications • Improved emissions over Maxon’s earlier NP AIRFLO units, with significantly lower CO and NO2 levels • Shorter flame length • Available in low pressure version and corrosion-resistant materials • Easily meets ANSI/CSA standards • Up to 1 MMBtu/h per foot; Up to 30:1 turndown CROSSFIRE® • Nozzle-mixing line burner for use with low pressure natural gas firing • Extremely low emissions — Capable of NOx levels of 25ppm and CO levels of 250ppm at 3% O2 • Temperature uniformity to enhance product quality • Also available in stainless steel housings or nickel-plated body • Up to 2.5 MMBtu/h per foot; Up to 25:1 turndown UNI-RAD® √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ Steel Mills APX® √ √ √ √ √ OPTIMA™ SLS √ KINEDIZER® LE √ √ Low Emissions Oven Burners MEGAFIRE® √ OVENPAK® 400 M-PAKT® √ Heat Treating and Furnace Burners KINEMAX® OVENPAK® LE TUBE-O-THERM® CROSSFIRE® √ √ √ TUBE-O-FLAME® NP-LE AIRFLO® Finding the right Maxon burner for your application APX® Burner Systems for Industrial Applications √ TUBE-O-FLAME® • Nozzle-mixing refractory-less burners for tube firing • Burns any clean low-pressure fuel gas • Increases heat transfer efficiencies with long swirling flame pattern • Flange-mounted compact design for easy installation • Low horsepower requirements reduce initial and operating costs • Produces low levels of NOx in combustion products • Generates less noise than open-port tube firing • Capacities to 5 MMBtu/h; Up to 20:1 turndown TUBE-O-THERM® • Burns natural gas, propane, or butane • Burner-to-tube direct firing system allows uniform heat transfer, eliminates hot spots,and produces faster bring-up times • Fires directly into small-bore immersion tubes • Designed with integral low-horsepower blower to lower costs and save energy • Wall- or tube-mount design for no-hassle installation and easy maintenance access • UV flame scanner capability for all four sizes • Capacities to 5.3 MMBtu/h Maxon information on Look for more rners, bu s, l system ro nt co n io st bu .com com online at Lesman ts uc od pr e lv and va Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 INDUSTRIAL BURNERS 17 OVENPAK® LE MEGAFIRE® • Burns any clean fuel gas,and operates on low gas supply pressures • Provides clean combustion with low NOx and CO levels • Compact burner design provides quick and easy installation • Balanced pressure design and visible ignition action for easy commissioning, adjustment and maintenance • Up to 6.5 MMBtu/h; Up to 100:1 turndown • Provides clean burning of #2 oil, natural gas or propane; Fires gas, oil, or both simultaneously • Inline blower version includes energy-efficient centaxial direct drive combustion air blower • Quiet operation with exceptionally low horsepower requirement • Nine different styles, three different sizes • Capacities to 45 MMBtu/h; 10:1 turndown on #2 oil, 15:1 turndown on natural gas M-PAKT® KINEDIZER® LE • Burns natural gas or propane • Extremely low emissions — Capable of single-digit NOx and CO levels at 3% O2 • Flame contained almost entirely inside the discharge sleeve • Durable steel outer construction with stainless steel internals • Compact design with a variety of control methods • Up to 8.4 MMBtu/h; Up to 13.5:1 turndown KINEMAX® • Burns most clean low-pressure gaseous fuels or light oil; Can be used with oxygen-enriched combustion air • Lower fuel consumption using preheated combustion air (up to 800°F) • Operate on-ratio with excess fuel or excess oil to meet specific demands of your combustion process • Exit velocities up to 275 ft/s to promote workload heat penetration and better furnace temperature uniformity • Refractory block for chamber temperatures up to 3000°F • Removable backplate gives easy access for inspection, maintenance • Seven sizes, capacities to 8.4 MMBtu/h; Up to 48:1 turndown OVENPAK® 400 • Burns any clean fuel gas; Requires only low-pressure gas • Fires into passing air streams • Provides clean combustion with low NOx levels • Simple field adjustment and maintenance • Compact burner design provides quick and easy installation • More than 90 different styles and sizes — including cost-effective external blower versions • Capacities to 16.5 MMBtu/h; Greater than 40:1 turndown • Burns natural gas, propane, or other fuel gases • Accepts preheated and vitiated combustion air • Field-proven low emissions; Stateof-the-art NOx firing, adjustable for application flexibility • Rugged design for oxidizers, process heaters, kilns, furnaces, dryers, waste incineration, and other high-temperature applications • Excellent stirring and mixing with medium velocity exhaust • Six sizes, capacities up to 75 MMBtu/h; Up to 22:1 turndown, with the lowest NOx and excess air in the KINEDIZER® family! OPTIMA™ SLS • Fuel flexible with natural gas, propane, and butane capability • Low NOx and CO production levels for extremely clean, reliable heat — and easy air permitting and environmental compliance • Large capacity heat releases with a compact, robust flame geometry • Intelligent ratio control provides reliable operation and optimal fuel efficiency • All steel and high temperature alloy construction for reduced weight, increased durability • Configurable for dryers, air heaters, ovens, kilns, process heaters, paper machines, and a variety of industrial heating equipment • Direct factory operational support with SMARTFIRE® control and communication gateway • Five sizes, capacities to 93.5 MMBtu/h; Up to 17.8:1 turndown UNI-RAD® • Radiant tube burner for fuel gas inputs • Suitable for use on pressure tubes, negative pressure tubes, and electrified radiant tubes • Flame length adjustable by changing combustion air-to-ignition ratios — produces optimum tube temperature uniformity over a wide range of firing rates and preheated air temperatures • Continuous plasma spark provides instantaneous ignition, so burner can operate from the DAT output of a PID control loop • Can be used in conjunction with UV flame supervision equipment BURNER CONTROLS V 10.2008 18 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 MicroM Flame Safeguard Burner Control System Model Selection Guide MicroM Flame Safeguard controls are compact, modular burn management systems designed to provide automatic ignition and continuous flame monitoring for commercial-sized heating and process burners firing any type of fuel. The MicroM incorporates remote reset capability and serial communications via MODBUS. The optional ED510 display can be used to access burner hours and cycles, system hours, the last 6 lockouts with burner cycle time stamp and programmer configuration. MODBUS communications capability allows the integration of the MicroM control into upper level energy management/data acquisition systems. A complete MicroM system consists of the appropriate flame scanner/detector, plug-in amplifier, and programmer modules connected to a chassis and wiring base. Interchangeable programmer and amplifier modules allow versatility in selecting control function, timing, and flame scanning method. All amplifiers are available with flame failure response times of 0.8 or 3 seconds nominal (4 seconds max), and each provide a set of test jacks with a range of 0-10VDC for the measurement of flame signal intensity. Smart LED indicators on all programmer modules indicate the current operating status of the control, and during a safety lockout, display the fault as a coded sequence, simplifying troubleshooting during a shutdown. A run-check switch is provided on the MEP500 series programmers to assist in testing size, position, and stability of the pilot. A safety checking circuit runs on each start. If flame (real or simulated) is detected prior to a start or during purge, the fuel valves will not be energized and the control will lock out. Catalog AvailComponent Description Number ability 120VAC Input , Standard Board MEC120 • • • • Chassis 120 VAC Input with Remote Reset Capability, Interface to Alphanu meric Display, Communications, Modbus Capability MEC120RC • • • • Programmer Relight Operation, 10 Sec. PTFI MEP100 • • • • Selectable Purge Timing, PTFI Timing, Recycle/Non-Recycle, Post Purge, Prove Air Open at Start MEP230 • • • • Selectable Purge Timing to 60 Min. MEP536 • • • • Non Self-Checking Scanner, 3 Ft. Flexible Cable, 1/2” NPT Connector UV1A3 ↓ Non Self-Checking Scanner, 6 Ft. Flexible Cable, 1/2" NPT Connector UV1A6 ↓ Flame Infrared Scanner, 8 Ft Shielded Scanners Cable with 90° Head 48PT2-9003 ↓ (See pg 20 Ultraviolet Self-Checking Scanner, for details) 120 VAC Shutter, 1" NPT Threads 45UV5-1009 ↓ Flame Rod for Gas Flames, 12" Length, 1/2" NPT Connection 69ND1-1000K4 ↓ UV Amplifier, 0.8 Sec Flame Failure Response Rate (FFRT) MEUV1 • UV Amplifier, 3 Sec FFRT MEUV4 • Infrared Amplifier, 0.8 Sec FFRT MEIR1 • Amplifier Infrared Amplifier, 3 Sec FFRT MEIR4 • Modules UV Self-Check Amplifier, 0.8 Sec FFRT MEUVS1 • UV Self-Check Amplifier, 3 Sec FFRT MEUVS4 • Flame Rod/Photocell Amplifier, 0.8 Sec FFRT MERT1 • Flame Rod/Photocell Amplifier, 3 Sec FFRT MERT4 • Wiring Closed Wiring Base, Surface Mount 61-3060 • • • • Base Open Wiring Base, Cabinet Mount 61-5042 • • • • Add functionality to your existing MicroM chassis*. Standard Local Reset Switch MED1 • • • • Standard Local Reset Switch with Display Output MED2 • • • • Standard Local Reset Switch with Remote Reset MED3 • • • • Option Standard Local Reset Switch Boards with Communications MED7 • • • • Standard Local Reset Switch, Display Output, and Remote Reset MED4 • • • • Standard Local Reset Switch with Display Output, Communications MED5 • • • • Standard Local Reset Switch with Display Output, Remote Reset, and Communications MED6 • • • • *MicroM chassis model MEC120RC includes all these options. MicroM Subbase Mounting Adapters The MicroM can fit directly onto your existing Honeywell Flame Safeguard mounting subbase with the addition of a single mounting adapter. No need to do any rewiring or expensive re-engineering for retrofits. Model Selection Guide Description MM-2 Mounting Adapter to Retrofit to R4795 Systems Catalog Number 60-1765 Price $96.60 Price $339.00 493.00 151.00 365.00 458.00 160.00 189.00 252.00 1373.00 106.00 74.30 74.30 149.00 149.00 160.00 160.00 74.30 74.30 64.50 68.50 35.10 58.30 81.70 129.00 117.00 142.00 175.00 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 BURNER CONTROLS 19 BurnerLogix™ Burner Management System Features • Keypad-configurable parameters — no dip switches to set! • Smart LEDs provide status and lockout codes — and provide operation without the need for the optional display • Alphanumeric display provides clear, concise messaging • Valve proof-of-closure during standby, startup, and shutdown • Modbus communications built in — adjustable baud rates allow for easy adaptation to burner control system • Open wiring base with terminal block allows testing with control installed; pigtail wiring base has color-coded and labeled leadwires • 4-20 mA test jack signal • New design with smaller footprint saves cabinet space BurnerLogix Model Selection Guide The Fireye Burner Logix System provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. In conjunction with limit and operating controls, it programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. A complete BurnerLogix system includes the YB110 chassis equipped with a flame amplifier, appropriate flame detector, plug-in programmer module, wiring base and optional alphanumeric display. The chassis/ flame amplifier module comes complete with mounting screws and blank display module. Interchangeable programmer modules allow for complete versatility in selection of control function, timing, and flame scanning means. The programming module determines functions like pre-purge time, recycling or non-recycling interlocks, high fire proving interlock, and trial for ignition timing of the pilot and main flame. The BurnerLogix system can be used with ultraviolet, auto-check infrared, flame rod, self-check ultraviolet flame scanners, or direct coupled by choosing the proper chassis/flame amplifier module. BurnerLogix’ operational characteristics are determined by the selection of the programmer module (e.g. modulation, recycle, non-recycle, fixed firing, flame failure response time, etc.). The programmer module incorporates a plug-in design for easy installation. Wiring bases for the BurnerLogix control are available pre-wired with 4 foot lead wires color coded and marked for easy installation or with an integral terminal block capable of accepting up to 2X 14 AWG wires. The wiring base terminal block is available with knockouts for conduit, or open ended for cabinet mounting. Catalog Description Number Price Step 1: Select Your BurnerLogix Chassis/Amplifier Module 120 VAC 50/60 Hz, with UV non-self-check amplifier YB110UV $1023.00 120 VAC 50/60 Hz, with UV self-check amplifier YB110UVSC 1262.00 120 VAC 50/60 Hz, with IR auto-check amplifier YB110IR 1192.00 120 VAC 50/60 Hz, with flame rectification amplifier YB110FR 1017.00 120 VAC 50/60 Hz, with direct-coupled amplifier, for use with Phoenix and Insight scanners YB110DC 1192.00 Step 2: Select Your BurnerLogix Programmer Module Keypad-selectable parameters, non-recycle operation, modulation, open damper proving, 4 second FFRT YP100 905.00 Keypad-selectable parameters, non-recycle operation, modulation, open damper proving, 2 second FFRT YP102 905.00 Keypad-selectable parameters, non-recycle operation, fixed TFI times, pilot proving, modulation, open damper proving, 1 second FFRT YP113 905.00 Keypad-selectable parameters, non-recycle operation, modulation, open damper proving, indefinite pilot hold, revert to pilot from auto, 4 second FFRT YP138 905.00 Keypad-selectable parameters, recycle operation, modulation, 4 second FFRT YP200 699.00 Keypad-selectable parameters, recycle operation, modulation, 2 second FFRT YP202 699.00 Keypad-selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT YP300 525.00 Keypad-selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT YP302 525.00 Step 3: Add an Optional BurnerLogix Display Module Vacuum fluorescent display (VFD), Good -40° to 140°F BLV512 520.00 Liquid crystal display (LCD), Good -4° to 140°F BLL510 520.00 NEMA 4 remote mount kit for display, 4 foot cable 129-178-4 56.00 NEMA 4 remote mount kit for display, 8 foot cable 129-178-8 61.00 Step 4: Select a Wiring Base 4” x 5”, 4 foot pigtail wires, color coded and labeled 60-2810-1 93.20 4” x 7” closed base with terminal block and knockouts 60-2812-1 93.20 4” x 7” open base with terminal block 60-2814-1 93.20 Step 5: Add an Optional Expansion Module Expansion module for first-out annunciation YZ300 996.00 Step 6: Select a Flame Scanner (See page 20 for details) Non Self-Checking Scanner, 3 Ft. Flexible Cable UV1A3 160.00 Non Self-Checking Scanner, 6 Ft. Flexible Cable UV1A6 189.00 Infrared Scanner, 8 Ft Shielded Cable with 90° Head 48PT2-9003 252.00 Ultraviolet Self-Checking Scanner 120 VAC Shutter 45UV5-1009 1373.00 12" Flame Rod for Gas Flames, 1/2" NPT Connection 69ND1-1000K4 106.00 Display Modules The BurnerLogix system offers vacuum fluorescent (VFD) and liquid crystal (LCD) displays that can be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information. Both displays contain a fully functional keypad so you can easily scroll through the various menus to view the current operating status, and review programmer configuration and lockout history. Remote mounted displays meet NEMA 4X requirements. BURNER CONTROLS V 10.2008 20 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Flame Monitor Series Burner Control System Flame-Monitor Series Flame Scanners The Flame-Monitor Series provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burners.Interchange able programmer and flame amplifier modules allow complete versatility in selecting control function. The flamemonitor control uses the same wiring base as the Fireye D-Series and C-Series Controls and is directly interchangeable with most models with out rewiring. The Flame-Monitor control can be used with ultraviolet, AUTOCHECK® infrared, photocell, flame rod or self-check ultraviolet flame scanners.Special features include remote reset, remote display, expanded annunciation of safety lockouts, programmability of safety interlock messages, and remote data communications capability. The complete Flame-Monitor control consists of a chassis, display module, programmer, amplifier, scanner and a wiring base. 69ND1: Flame rod made of high temperature resistant metal. Can only be used to detect gas flames. Rods are available in 12”, 18”, and 24” lengths. UV1A: Ultraviolet miniature non selfchecking scanners suitable for fuel gases and #2 oil.Non-replaceable tube.Mounting collar 1/2” NPT. 48PT2: Lead sulfide scanner is designed to detect low frequency IR signals from gas or oil flames. Mounting collar is 1/2” NPT with straight or 90° mounts. 8 ft. flexible conduit. Replaceable sensor cell. 45UV5: Self-checking ultraviolet scanner for continuously fired applications where recycling in infrequent or absent.The self-checking circuit checks the electronics and the UV tube for proper operation every 4 seconds during the firing period.Suitable for fuel gases and oil.Replaceable UV tube and shutter mechanism. Mounting 1” NPT. Must be installed with metal shielding over the scanner leads. EP Programmer Module Flame Amplifier Module The Fireye EP Programmer Modules provide start-up programming, safe start check, and flame monitoring supervision. They ensure open damper high fire purge interlock, proof of low fire position and fuel valve end switch safety checks. A running interlock circuit constantly monitors the limit switches, air flow switches and fuel pressure switches throughout the programmer. EP programmer modules will de-energize all fuel valve circuits within 4 seconds following a flame failure or at the end the pilot-trail-for-ignition period if no flame is detected. The EP programmers provide a Check-Run switch to stop the control in its firing sequence at any time (except MTFI) to aid in setup, start-up, and check out of the burner and its associated interlocks. EP programmers offer the following functions: an increase of purge timing and air flow switch opened at the start of the operating cycle. EP programmers include an RJ45 style connector to interface with the ED510 display module. EP programmers store the burner cycle and ontime history, as well as lockout history (with burner cycle and burner hour time stamp). ED510 Display Module • • • • LCD backlit display with 2 lines of 16 characters each RJ style connector Mounts directly onto front face of programmers Continuous display of current burner status, including first out annunciation in the event of a lockout condition • Remote display using DIN-sized opening and remote mounting kit. • 3-key keypad provides historical data from the burner, the last 6 lockout conditions (with burner cycle and burner hour time stamp) Flame amplifier modules are used with the appropriate flame scanner to provide flame scanning capability. Fireye offers ultraviolet amplifiers and flame rectification amplifiers for use with flame rods, photocells and autocheck infrared amplifiers. Self-checking ultraviolet scanners and amplifiers should be used in applications where burner firing operation is continuous or where the burner is on for long periods of time without cycling. Model Selection Guide Catalog AvailComponent Description Number ability Price Chassis 120VAC Chassis with Mounting Screws and Dust Cover E110 • • • • $701.00 Program 30 Sec. Purge, 10/15 Sec. TFI, 4 Sec. Module FFRT, Non-Recycle Modulation EP160 • • • • 952.00 Display 2 Line x 16 Character LCD Display with Keypad ED510 • • • • 494.00 Flame Non Self-Checking Scanner, 3 Ft. Scanner Flexible Cable, 1/2” NPT Conn. UV1A3 ↓ 160.00 Non Self-Checking Scanner, 6 Ft. Flexible Cable, 1/2" NPT Conn. UV1A6 ↓ 189.00 Infrared Scanner, 8 Ft Shielded Cable with 90° Head 48PT2-9003 ↓ 252.00 Ultraviolet Self-Checking Scanner 120 VAC Shutter, 1" NPT Thread 45UV5-1009 ↓ 1373.00 12" Flame Rod for Gas Flames, 1/2" NPT Connection 69ND1-1000K4 ↓ 106.00 Standard Ultraviolet Amplifier EUV1 • 373.00 Amplifier Autocheck Infrared Amplifier E1R1 • 552.00 Module Self-Check Ultraviolet Amplifier EUVS4 • 625.00 Flame Rectification Amplifier ERT1 • 367.00 Wiring Surface Mount 60-1386-2 • • • • 105.00 Base Panel Mount 60-1466-2 • • • • 105.00 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 BURNER CONTROLS 21 MB Series Industrial Multiburner Flame Safeguard System Modulation for Purge and Low Fire Start Control A single MBPF amplifier module handles UV, UV Self-Check and Flame Rod scanners Four Auxiliary Inputs Valve Leak Detection Interface LED indicator alert you to process step and status Up to four burner amplifiers mounted on MB-600 Optional Expansion Modules for control of up to 20 burners Connects to optional Remote Display Module The Fireye Multi-Burner Monitoring System controls the start-up sequence and monitors the flame of up to 20 individual gas, oil or combination gas/oil burners connected to a common valve train. Dynamic on-board diagnostics check for faulty relays, proof of valve closure, high and low fire switch interlocks, and shortened air switch. The MB is even able to specifically identify which burner caused the initial flame failure. Plug-in flame sensor modules that can sense UV, UV self-check or flame rod provide for easy replacement on an individual basis. Configuration and startup time is reduced through use of on-board DIP switches, which also allow sequencing and timing functions. The MB-600S chassis directly powers pilot and main gas valves and ignition transformers. The built in blower output, purge timing and modulation control, let you add independent limits and a controller to create a complete combustion control system for furnace, oven or other multi-burner applications. UV7A4 UV Scanner Specifications Number of Burners: 20 max. UV7R4 90° UV Scanner Pilot Proving Time: 7 seconds Purge Time: 0 sec to 60 min Pilot Trial for Ignition: 5, 10 or 15 seconds UV7SC Self-Check Flame Failure Response Time: 3 (±0.5) seconds UV Scanner Valve Operation: Simultaneous (all burners operate from one fuel train) Supply Voltage: 120VAC, 50/60 Hz; Power Consumption: 25VA Temperature Rating: -32° to 122°F (-36° to 50°C) Contact Ratings: Fan Motor: 15 Amp Resistive; Others: 10 Amp Resistive Model Selection Guide Catalog Description Number Price Step 1: Select a Chassis for your Multiburner Control System 120VAC 50/60Hz, Motherboard, Relay Board, Logic Module, and Power Module. 4 Auxiliary Inputs, Purge Modulation, Valve Leak Testing MB-600S $1769.00 120VAC 50/60Hz, Motherboard with RS-232 Communications, Relay Board, Logic Chassis Module, Power Module. 4 Auxiliary Inputs, Purge Modulation, Valve Leak Testing MB-632S 1903.00 120VAC 50/60Hz, Motherboard with RS-485 Communications, Relay Board, Logic Module, Power Module. 4 Auxiliary Inputs, Purge, Modulation, Valve Leak Testing MB-685S 1903.00 Step 2: Select a Flame Sensor Module Sensor Plug-In Flame Sensor Module, UV/FR Module Plastic Case with Mounting Screws MB-600PF 354.00 Step 3: For Systems with More than 4 Burners, Select Expansion Board Modules and Cables Expansion Board for up to 4 Burners MB-604E 316.00 Expansion Expansion Board for up to 8 Burners MB-608E 638.00 Modules 6” Cable for Expansion Board 59-506-1 34.40 36” Cable for Expansion Board 59-506-3 48.60 Step 4: Select Optional Remote Display and Cable Remote Display with Keypad MB510 448.00 Display 6 Ft. Cable for Remote Display 59-507-6 23.60 10 Ft. Cable for Remote Display 59-507-10 35.40 Step 5: Select One Flame Scanner for Each Burner on Your System 1/2” NPT Straight UV Scanner, 4 Ft. Flex Conduit, Insulated Nylon Coupling UV7A4 181.00 1/2” NPT UV Scanner, NEMA 4, 4 Ft. Flex Scanners Conduit, Insulated Nylon Coupling UV7A4W 241.00 and 1/2” NPT 90° UV Scanner, 6 Ft Shielded Cable UV7R4 148.00 Accessories 1” NPT Self-Check Scanner UV7SC 970.00 10 Ft Cable for UV7SC Self-Check Scanner 59-504-010 150.00 Scanner Support, Max Temp 200°F 36-935 35.60 Magnifying Lens Assembly 46-185 90.60 Magnifying Lens 46-186 22.20 Non-Magnifying Lens 46-187 28.20 1/2” NPTF Insulated Nylon Coupling 35-319 17.40 Tip: If your system has between 4 and 8 burners, select 1 MB-604E module and a connecting cable. If your system has between 9 and 13 burners, select 1 MB608E module and a connecting cable. For systems that have 14 to 20 burners, you can mix MB-604E and MB-608E modules to fit. 65UV5 Integrated Flame Scanner with Internal Flame Relay The 65UV5 flame scanner incorporates an internal single pole, single throw (normally open) flame relay with a fixed on/off threshold to provide flame on/flame off indication, eliminating the need for an external flame amplifier. The scanner uses an ultraviolet tube-type sensor, and electromechanical self-checking shutter mechanism. The NEMA 4X/IP66 housing is suit- able for use in Class I Division II, Group C and D hazardous environments. The Fireye 65UV5 flame scanner is powered by 24 VDC and includes an integral 10-foot four-conductor cable with cable gland. Two color-coded internal LEDs indicate flame status (off/on) and alarm condition. These can be viewed through the removable rear access screw opening. Model Selection Guide Description Integrated Flame Scanner, 1” NPT Mounting Flange, 4 Second Flame Failure Response Time Catalog Number 65UV5-1004 Price $1544.00 BURNER CONTROLS V 10.2008 22 Lesman Instrument Company Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Flame Relays and Burner Control Units Choosing the Right Kromschroder Burner Control Operating Time Ignition Type IFS 258 IFS 110IM BCU 370 < 24 Hours < 24 Hours > 24 Hours Direct Direct Direct or Pilot Burner Signal Line Length 75M Max 50M Max 50M Max Behavior at Flame Failure Switchable: Fault Lockout or Restart Fault Lockout and/or Restart Programmable Gas Valve Outputs 1 2 2 IFS 258 Burner Control Unit For use in single- and multiburner atmospheric or forced-air burner systems. Can be used with on/off, high/low or proportional control. Add external timer to provide purge timing. Model Selection Guide • Compatible with flame rods or UV detectors • Front panel indicators display burner unit on, flame on, and flame failure information • Start/stop/reset switch on front of unit • Can be programmed to restart or immediate fault lockout following flame failure • CSA, FM approved Pilot Flame Catalog Description Establishing Period Number Price Burner control unit for intermittent operation with switchable fault lockout or restart, FFRT 2 seconds IFS 258T-3/2R 3 seconds 84620420 $307.00 IFS 258T-5/2R 5 seconds 84620440 307.00 IFS 258T-10/2R 10 seconds 84620460 307.00 IFS 110IM Burner Control Unit Automatic burner control for ignition and control of gas burners in gas-firing installations of all types. Designed for high cycling frequency and long life. T Add an IFW 15 ur yo to y la re e flam r fo IM IFS 110 rol. multiburner cont • Flame control by means of flame rods or Model Selection Guide UV detectors Pilot Flame Catalog • Performs flame simulation check before Description Establishing Period Number Price starting burner and after switching off Burner control unit for intermittent pilots, FFRT 2 seconds, fault • Semiconductor output for ignition trans- lockout and restart following flame failure former — no switch contacts IFS 110IMT-3/2/2N 3 seconds 84367700 $414.00 IFS 110IMT-5/2/2N 5 seconds 84367710 414.00 • High cycling frequency IFS 110IMT-10/2/2N 10 seconds 84367720 414.00 • Remote reset Burner control unit for intermittent operation FFRT 2 seconds, • External fault indication restart following flame failure • FM approved IFS 110IMT-W-3/2/2N 3 seconds 84367750 434.00 • Can be used for multiburner control by IFS 110IMT-W-5/2/2N 5 seconds 84367760 434.00 adding flame relay IFW 15T IFS 110IMT-W-10/2/2N 10 seconds 84367770 434.00 IFW 15T Flame Relay Detect and signal existing flame. • • • • • Compatible with flame rods or UV detectors Potential-free contacts Integrated ON lamp Use with IFS 110IM for multiburner control Great for letting your PLC know when flame is present Model Selection Guide Catalog Description Number Price Flame relay. Use with IFS 110IM burner control for multiburner apps. IFW 15T-N Flame Relay 84359100 $200.00 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 BURNER CONTROLS 23 BCU 370 Burner Control Unit Controls, ignites, and monitors industrial forced-air burners of unlimited capacity in intermittent or continuous operation. Can be used for direct-ignited or pilot-burner systems. • Controls fan and butterfly valve, monitors gas and air pressure • Manual operating mode and informative operating, warning, and fault messages make startup, service, and and maintenance simple • Optional integrated tightness control function checks valves with a DG gas pressure switch • Quick-start option allows standard-compliant startup of forced air burner without pre-purge after normal shutdown • Programmable via optical interface and BCSoft PC software Model Selection Guide Catalog Description Number Price For controlling, igniting, and monitoring industrial forced-air burners, intermittent operation, ionization or UV control. 120 VAC 50/60 Hz power, fan (blower) and butterfly valve control BCU 370QFEU0D1 No ignition unit, flame control DGmax 88600122 $530.00 BCU 370QI1FEU0D1 Single-pole electronic ignition, flame control DGmax 88600249 650.00 BCU 370QI1FEU0D1B1 Single-pole electronic ignition, flame control DGmax, ProfiBUS-DP interface 88600236 858.00 BCU 370QFEU0D3B1-3 No ignition unit, integrated tightness control, ProfiBUS-DP interface and butterfly valve control over ProfiBUS 88600121 1111.00 Opto Adapter and BCSoft CD-ROM for BCU 370s 74960437 263.00 UVS 8T Ultraviolet Flame Detector For use in forced and induced draft burners, ovens, gas-fired boilers, industrial furnaces, and installations for the flaring of excess gas. • • • • High sensitivity over an ambient temperature range -40° to 176°F Insensitive to sunlight, daylight, infrared radiation, and incandescent lamps UV tube life expectancy of 10,000 operating hours Protects against interruptions or short circuits in the flame Model Selection Guide signal line Catalog • Rugged aluminum construction with integral 1/2” NPTF Description Number threaded collar and 6-foot leads UVS 8T Ultraviolet Detector 84333120 UV Replacement Tube 74960445 • FM approved Price $134.00 111.00 Coming soon to Lesman.com: Buy Kromschroder burner controls from our secure web store! When you need to learn more, the Lesman website has: • Downloadable specifications • Dimensional drawings • 24/7/365 availability Visit us anytime at www.lesman.com PRESSURE CONTROLS V 10.2008 24 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Pressure Switches for Gas Applications DG Pressure Switches Monitors positive air and gas pressures, negative or differential air pressures in industrial and commercial applications. • Accurate repeatable switching action with low hysteresis • Die-cast aluminum alloy base,glass fiberreinforced plastic switch housing, nitrile rubber diaphragm, and high-quality injection-molded plastic covers • One normally open and one normally closed contact in each switch (5A resistive or 0.5A inductive • Automatic and manual reset models • 8A quick-acting fuse for short circuit protection • FM approved, cULus listed Model Selection Guide Adjustable Catalog Description Range Connection Number Price DG..T pressure switch with 110V control lamp (green) for positive, negative, and differential pressure, automatic reset DG 6T 0.2” to 2.4” WC 1 x 1/4” NPT 84447800 $64.00 DG 10T 0.4” to 4” WC 1 x 1/4” NPT 84447810 64.00 DG 50T 1.0” to 20” WC 1 x 1/4” NPT 84447820 64.00 DG 150T 12” to 60” WC 1 x 1/4” NPT 84447830 64.00 DG 500T 40” to 200” WC 1 x 1/4” NPT 84447840 64.00 DG 6T 0.2” to 2.4” WC 2 x 1/4” NPT 84447802 63.00 DG 10T 0.4” to 4” WC 2 x 1/4” NPT 84447812 63.00 DG 50T 1” to 20” WC 2 x 1/4” NPT 84447822 63.00 DG 150T 12” to 60” WC 2 x 1/4” NPT 84447832 63.00 DG 500T 40” to 200” WC 2 x 1/4” NPT 84447842 63.00 DG..HT pressure switch with manual reset, locks on pressure rise DG 10HT 0.4” to 4” WC 2 x 1/4” NPT 84447912 77.00 DG 50HT 1.0” to 20” WC 2 x 1/4” NPT 84447922 77.00 DG 150HT 12” to 60” WC 2 x 1/4” NPT 84447932 77.00 DG 500HT 40” to 200” WC 2 x 1/4” NPT 84447942 77.00 DG..NT pressure switch with manual reset, locks on pressure fall DG 10NT 0.4” to 4” WC 2 x 1/4” NPT 84447962 77.00 DG 50NT 1.0” to 20” WC 2 x 1/4” NPT 84447972 77.00 DG 150NT 12” to 60” WC 2 x 1/4” NPT 84447982 77.00 DG 500NT 40” to 200” WC 2 x 1/4” NPT 84447992 77.00 DG..VT Safety Limit Pressure Switches Diaphragm-actuated safety limit switch controls rising or falling pressures that must not overshoot or undershoot a set limit Model Selection Guide value, and controls the minimum Adjustable Catalog Range Connection Number Price or maximum gas inlet pressure of a Description DG pressure switch with 4-pin plug, socket, and 18” flexible leads gas control line. • For use with natural gas and air • Die-cast aluminum base, glass-filled PBT switch housing, NBR diaphragm, and polycarbonate cover • Available with Valvario mount for direct connection to Kromschroder modular valve trains • Ambient temperatures 5° to 140°F • 4-pin DIN/Amp plug wiring connector DG 17VCT6-6W DG 40VCT6-6W DG 110VCT6-6W DG 300VCT6-6W DG 17VCT8-6W DG 40VCT8-6W DG 110VCT8-6W DG 300VCT8-6W DG 17/VCT1-6W DG 40/VCT1-6W DG 110/VCT1-6W DG 300/VCT1-6W 0.8” to 6.8” WC 2.0” to 16” WC 12” to 44” WC 40” to 120” WC 0.8” to 6.8” WC 2.0” to 16” WC 12” to 44” WC 40” to 120” WC 0.8” to 6.8” WC 2.0” to 16” WC 12” to 44” WC 40” to 120” WC 1/8 NPTM 1/8 NPTM 1/8 NPTM 1/8 NPTM 1/4” NPTM 1/4” NPTM 1/4” NPTM 1/4” NPTM Valvario Valvario Valvario Valvario 84448040 84448840 84448440 84448940 84448090 84448890 84448490 84448990 75454583 74214174 75454585 75454586 $49.00 49.00 49.00 49.00 49.00 49.00 49.00 49.00 78.00 78.00 78.00 78.00 The new RAECO Rents instrumentation catalog is now available! Get yours FREE! • Looking for portable LEL monitors or combustion efficiency analyzers? Check with our partners at RAECO! • Rentals available on a daily, weekly, or monthly basis • All parts, accessories, and software available • Automatic 5% rental fee discount when you rent online at www.raeco.com Visit www.raeco.com to request a print catalog or download the free PDF. Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 BUTTERFLY VALVES 25 Butterfly Valves and Actuators BV Butterfly Valves High accuracy valves for control of gas flow rates. Mount on IC 20 or IC 40 actuators to regulate flow rates for modulating or stage-controlled combustion systems. • Low leakage rate and pressure loss • Other models available for flue gas and high temperature air flow rates to 840°F. Call Lesman for details Model Selection Guide Temperature Bore Nominal Reduced Compatible Catalog Model Range Size Diameter Nominal Diam. Actuator Number Butterfly valve for continuous control of gas flow rates, ratio of 10:1. Maximum inlet pressure 7.25 PSI. BVG 40TW05 -4° to 140°F Full 1 1/2” IC 20 or IC 40 74105790 BVG 65TW05 -4° to 140°F Full 2 1/2” IC 20 or IC 40 74105792 BVG 50TW05 -4° to 140°F Full 2” IC 20 or IC 40 74105791 BVG 80TW05 -4° to 140°F Full 3” IC 20 or IC 40 74105793 BVG 100TW05 -4° to 140°F Full 4” IC 20 or IC 40 74105794 BVG 40/32TW05 -4° to 140°F 1X Reducing 1 1/2” 1 1/4” IC 20 or IC 40 74214264 BVG 50/40TW05 -4° to 140°F 1X Reducing 2” 1 1/2” IC 20 or IC 40 74214263 BVG 65/50TW05 -4° to 140°F 1X Reducing 2 1/2” 2” IC 20 or IC 40 74214262 BVG 80/65TW05 -4° to 140°F 1X Reducing 3” 2 1/2” IC 20 or IC 40 74105783 BVG 100/80TW05 -4° to 140°F 1X Reducing 4” 3” IC 20 or IC 40 74105784 BVG 40/25TW05 -4° to 140°F 2X Reducing 1 1/2” 1” IC 20 or IC 40 74214267 BVG 65/40TW05 -4° to 140°F 2X Reducing 2 1/2” 1 1/2” IC 20 or IC 40 74214265 BVG 50/32TW05 -4° to 140°F 2X Reducing 2” 1 1/4” IC 20 or IC 40 74214266 BVG 80/50TW05 -4° to 140°F 2X Reducing 3” 2” IC 20 or IC 40 74105875 BVG 100/65TW05 -4° to 140°F 2X Reducing 4” 2 1/2” IC 20 or IC 40 74105782 Price $196.00 226.00 208.00 257.00 273.00 255.00 294.00 316.00 361.00 376.00 255.00 316.00 294.00 361.00 401.00 Compatible Valve Actuators for BV Butterfly Valves Reversible gear motors to transmit rotary movements between 0° and 90°. • IC 20 for basic applications with continuous or three-point step control, automatic/manual mode changeover for easy commissioning. IC 20..E is controlled by 0/4-20 mA or 0-10V signal • IC 40 for complex applications with programmable functions for flexible adjustment to the process. Compatible with BCSoft for data monitoring, troubleshooting, and programming Model Selection Guide Torque Run Time Controlling Description (Lb-in) (Over 90° Stroke) Signal IC 20 Reversible gear motor, 120 VAC, 50/60 Hz IC 20-07Q2 22 Lb-in 7.5 seconds Three-point step IC 20-15Q3 26.5 Lb-in 15 seconds Three-point step IC 20-30Q3 26.5 Lb-in 30 seconds Three-point step IC 20-60Q3 26.5 Lb-in 60 seconds Three-point step IC 20-07Q2E 22 Lb-in 7.5 seconds Continuous IC 20-15Q3E 26.5 Lb-in 15 seconds Continuous IC 20-30Q3E 26.5 Lb-in 30 seconds Continuous IC 20-60Q3E 26.5 Lb-in 60 seconds Continuous Torque Description (Lb-in) Additional Input/Output Functions IC 40 Reversible gear motor, 100-230 VAC, 50/60 Hz IC 40TA2 22 Lb-in — IC 40TA2A 22 Lb-in 4-20 mA input IC 40TA2R10 22 Lb-in 1000Ω feedback potentiometer IC 40TA2AR10 22 Lb-in 4-20 mA input and 1000Ω feedback potentiometer IC 40TSA3 26.5 Lb-in Safety closing function IC 40TSA3A 26.5 Lb-in Safety closing, 4-20 mA input IC 40TSA3R10 26.5 Lb-in Safety closing, 1000Ω feedback potentiometer IC 40TSA3AR10 26.5 Lb-in Safety closing, 4-20 mA input, 1000Ω feedback potentiometer Loose (/B) IC 20/40 Attachment Set 74921671 $74.00 IC 20/40 Adapter - Free Shaft End 74921676 60.00 IC 20/40 Adapter - Manual Adjustment 74921678 47.00 IC 20/40 Adapter - Square Shaft 74921674 74.00 IC 40 Accessory: Fastening Set IC-BV 74921082 8.00 Catalog Number 74105712 74105713 74105714 74105715 74105998 74105999 74106000 74106001 Catalog Number Price $311.00 311.00 311.00 311.00 741.00 741.00 741.00 741.00 Price 74105760 $603.00 74105761 620.00 74105762 691.00 74105763 746.00 74105764 736.00 74105765 795.00 74105766 820.00 74105767 879.00 Assembled /E) 74921747 $69.00 74921677 68.00 52.00 74921679 74921675 69.00 74921084 9.00 y Need a butterfl s ga ue fl r fo valve ture or high tempera ll Ca air flow rates? g in ic pr r fo Lesman y. lit bi la ai and av SOLENOID VALVES V 10.2008 26 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Compact Solenoid Valves Valvario® VAS Safety Shut-Off Solenoid Valves Normally closed solenoid valves for gas. For safeguarding and controlling air and gas supply to gas burners and appliances. For use in gas control and safety systems in all sectors of the iron, steel, glass, and ceramics industries, plus commercial heat generation in packaging, paper, and food industries. • Modular design saves space and piping work • Main gas valve, pilot valve, regulator and pressure switch are all available for direct “stack” mounting for one small modular footprint • Changeable mounting plates make it easy to reduce input/output size and flange size. Reduces need for keeping multiple sizes in inventory • Modular-mount mercury-free pressure switch has test port and <25% deadband • Can be equipped with Proof of Closure visual indicator • High flow rate and low pressure drop • CSA, FM, CE approvals Model Selection Guide Flow Rates Specifications Inlet Pressure: (pe): 7 PSIG max Non-Operational Pressure: FM approved: 10 PSIG; CSA approved: 5 PSIG Flow Adjustment: Limits max flow between 20% and 100%. On VAS 1-3 sizes, the setting can be monitored on an indicator Adjustment of Start Gas Rate: 0% to 70% Opening Times: VAS/N quick opening: ≤1sec; VAS/L slow opening: up to 30 sec Closing Time: <1 second Ambient Temperature: -4° to 140°F Safety Valve: Class A, Group 2, pursuant to EN 13611 and EN 161; FM research class 7410 and 7411, ANSI Z21.21, CSA 6.5 Materials: IP65 enclosure; Valve housing: Aluminum, Valve seal: NBR Voltage: 120 VAC, 50/60 Hz Current Consumption (at 68°F): Pickup: 1.8 amp; Holding: 0.3 amp Switching Frequency: 5x per minute, except VAS 9: Once per minute Switching Cycles: 0.1 amp: 500,000; 0.5 amp: 300,000; 1 amp: 200,000; 3 amp: 100,000 Valve Inlet/Outlet Catalog Series Size Flange Size Number Price VAS Quick Opening, NPT Threaded Connection VAS 1T10N/NQ 1 3/8” 88001831 $181.00 VAS 1T15N/NQ 1 1/2” 88001832 181.00 VAS 1T20N/NQ 1 3/4” 88001842 215.00 VAS 1T25N/NQ 1 1” 88001830 224.00 VAS 2T25N/NQ 2 1” 88001849 288.00 VAS 2T32N/NQ 2 1 1/4” 88001850 288.00 VAS 2T40N/NQ 2 1 1/2” 88001851 296.00 VAS 2T50N/NQ 2 2” 88001852 296.00 VAS 3T40N/NQ 3 1 1/2” 88001853 404.00 VAS 3T50N/NQ 3 2” 88001854 404.00 VAS 3T65N/NQ 3 2 1/2” 88001855 432.00 VAS Quick Opening, ANSI Flanged Connection, No Accessory Connection VAS 6T65A05NQP 6 2 1/2” 88200132 854.00 VAS 7T80A05NQP 7 3” 88200148 1357.00 VAS 8T100A05NQP 8 4” 88200162 1835.00 VAS 9T125A05NQP 9 5” 88200160 2923.00 VAS Quick Opening, ANSI Flanged Connection, Two Screw Plug Connections for Accessory Connections at Right Inlet/Outlet VAS 6T65A05NQP/PP/PP 6 2 1/2” 88200385 1028.00 VAS 7T80A05NQP/PP/PP 7 3” 88200390 1533.00 VAS 8T100A05NQP/PP/PP 8 4” 88200394 2014.00 VAS 9T125A05NQP/PP/PP 9 5” 88200427 3106.00 VAS Slow Opening, NPT Threaded Connection VAS 1T10N/LQ 1 3/8” 88001856 226.00 VAS 1T15N/LQ 1 1/2” 88001857 226.00 VAS 1T20N/LQ 1 3/4” 88001858 269.00 VAS 1T25N/LQ 1 1” 88001859 269.00 VAS 2T25N/LQ 2 1” 88001860 333.00 VAS 2T32N/LQ 2 1 1/4” 88001861 333.00 VAS 2T40N/LQ 2 1 1/2” 88001862 342.00 VAS 2T50N/LQ 2 2” 88001863 342.00 VAS 3T40N/LQ 3 1 1/2” 88001864 450.00 VAS 3T50N/LQ 3 2” 88001865 450.00 VAS 3T65N/LQ 3 2 1/2” 88001869 479.00 VAS Slow Opening, ANSI Flanged Connection, No Accessory Connection VAS 6T65A05LQP 6 2 1/2” 88200133 936.00 VAS 7T80A05LQP 7 3” 88200149 1439.00 VAS 8T100A05LQP 8 4” 88200163 1917.70 VAS Slow Opening, ANSI Flanged Connection, Two Screw Plug Connections for Accessory Connections at Right Inlet/Outlet VAS 6T65A05LQP/PP/PP 6 2 1/2” 88200387 1110.00 VAS 7T80A05LQP/PP/PP 7 3” 88200391 1615.00 VAS 8T100A05LQP/PP/PP 8 4” 88200395 2095.00 Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 www.lesman.com sales@lesman.com V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 SOLENOID VALVES 27 Solenoid Valves for Combustion Systems Comparing ASCO Combustion Valves Valve Parts In Contact with Fluids Approvals 8030 8040 8210 8214 8215 8262 Brass body 305 SS core tube NBR seals/disc 430F SS core/plugnut Copper shading coil 302 SS springs Aluminum body 305 SS core tube NBR seals/disc 430F SS core/plugnut Copper shading coil 302 SS springs Zinc-plated steel pipe plug Brass body 305 SS core tube NBR seals/disc 430F SS core/plugnut Copper shading coil Aluminum body 305 SS core tube NBR seals/disc 430F SS core/plugnut Copper shading coil 302 SS springs Zinc-plated steel pipe plug Aluminum body 305 SS core tube NBR seals/disc/ diaphragm 430F SS core/plugnut 302 SS or 17-7 PH springs Copper shading coil CA core guide 305 SS core tube Brass body 305 SS core tube NBR seals/disc 430F SS core/plugnut Copper shading coil Inconel 600 springs Acetal core guide PTFE rider ring UL, FM, CSA UL, CSA, FM (3/8” to 3/4” only) UL, FM, CSA UL, FM, CSA UL, CSA, FM (except 8215A090 and 8215A040) UL, FM, CSA Model Selection Guide 120 volts AC/60 Hz — All Valves Shown Here are Normally Closed (Closed when De-Energized), Suitable for Use in Fluids to Maximum Temperatures 125°F Operating Pressure Cv Gas Differential (PSI) Pipe Orifice Flow Capacity Size Size Factor BTU/Hr Min. Max. Direct Acting Gas Shutoff Valves 1/8” 5/16” 1 53,700 0 15 1/4” 9/32” 0.96 51,700 0 40 1/4” 5/16” 1.1 59,000 0 15 3/8” 3/8” 1.8 97,000 0 15 1/2” 7/16” 2.8 151,000 0 8 1/2” 3/4” 5.4 291,000 0 2 3/4” 3/4” 9.5 512,000 0 2 1” 1-5/8” 16.8 900,000 0 0.5 Pilot Operated Gas Shutoff Valves 3/8” 5/8” 2.8 150,000 0 50 3/8” 3/4” 3.4 183,000 0 50 1/2” 5/8” 3.6 193,000 0 50 1/2” 3/4” 4.4 238,500 0 50 3/4” 5/8” 5.0 295,000 0 50 3/4” 3/4” 5.1 247,500 0 50 3/4” 1-5/8” 11 580,000 0 50 1” 1-5/8” 21 1,119,000 0 25 1-1/4” 1-5/8” 32 1,730,000 0 25 1-1/2” 1-5/8” 35 1,900,000 0 25 2” 2-3/32” 60 3,251,000 0 25 2-1/2” 3” 117 5,821,000 0 5 3” 3” 138 7,430,000 0 5 Gas Shutoff Valves with Waterproof Enclosures 3/8” 3/4” 3.4 183,000 0 5 1/2” 3/4” 4.4 238,500 0 5 3/4” 3/4” 5.1 247,500 0 5 Watt Rating/ Class of Coil Insulation Solenoid Valve Catalog Number Price Each Repair Kit Catalog Number Price Each Replacement Coil Catalog Number Price Each 6.1/F 10.1/F 10.1/F 10.1/F 10.1/F 10.1/F 10.1/F 15.4/F 8040H006 8262G078 8040H007 8030G068 8030G069 8040G022 8040G023 8040C004 $64.00 65.00 65.00 154.00 157.00 127.00 132.00 158.00 318247 306631 318247 306628 306629 306633 306633 304079 $66.00 47.00 66.00 104.00 108.00 63.00 63.00 104.00 238210-032-D 238610-032-D 238210-032-D 238610-032-D 238610-032-D 238610-032-D 238610-032-D 099257-001-D $61.00 69.00 61.00 69.00 69.00 69.00 69.00 91.00 10.1/F 10.1/F 10.1/F 10.1/F 10.1/F 10.1/F 15.4/F 15.4/F 15.4/F 15.4/F 15.4/F 28.2/F 28.2/F 8210G074 8215G010 8210G075 8215G020 8210G076 8215G030 8215 135 8215B050 8215B060 8215B070 8215B080 8215A090 8215A040 179.00 135.00 179.00 135.00 196.00 139.00 250.00 252.00 252.00 292.00 428.00 835.00 835.00 304076 302350 304076 302350 304076 302350 302352 302352 302352 302352 302353 302354 302354 128.00 104.00 128.00 104.00 128.00 104.00 184.00 184.00 184.00 184.00 221.00 362.00 362.00 238610-032-D 238610-032-D 238610-032-D 238610-032-D 238610-032-D 238610-032-D 099257-001-D 099257-001-D 099257-001-D 099257-001-D 099257-001-D 206409-011-D 206409-011-D 69.00 69.00 69.00 69.00 69.00 69.00 91.00 91.00 91.00 91.00 91.00 188.00 188.00 143.00 143.00 143.00 238610-132-D 238610-132-D 238610-132-D 83.00 83.00 83.00 17.1/F 8214G010 17.1/F 8214G020 17.1/F 8214G030 135.00 316233 135.00 316233 139.00 316233 Looking for another ASCO solenoid valve? Call Lesman’s solenoid valve specialists at 800-837-1700. We stock deep! STACK GAS ANALYZER Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 V 10.2008 28 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Stack Gas and Combustion Efficiency Analyzers Zircomat In-Situ Stack Gas Oxygen Analyzer Probe Stack Gas Out Detector Stack Wall Features • Simple to install and maintain • One detector fits all Zircomat probes • Detector removes for easy cleaning and repair; probe stays in place • Calibrates automatically • • • • • • Field selectable ranges Selectable memory hold feature Hi-Lo and self-diagnostic alarms Interactive message panel Isolated 4-20 mA output signal Extractive sample cell available Call Lesman for the help specifying fo right model r your application. Stack Gas In Refineries and power plants measure excess oxygen to improve their energy efficiency and reduce fuel consumption. In most oxygen analyzers, the electronic sensor comes in direct contact with the sample gas, so you have to remove the hot probe every time you service the sample gas filter or the sensor. And, you need to stock probe-length-specific spare parts inventory for these systems. Cosa Zircomat oxygen analyzers are more user-friendly.In the Zircomat system, the sample gas is deflected to the sensor. To increase safety, the probe always stays in the stack. The small, hand-held oxygen detector is quickly detachable for service. And, one detector fits all Zircomat probes, any model any length! Small and easily detachable, the Zircomat detector can be serviced without removing the probe from the flue stack. You won’t need to shut down your plant just to remove the probe. A replaceable sample gas diffuser on the end of the detector provides sensor protection. The microprocessor-based transmitter has a large LED display for oxygen concentration and a 4-20 mA isolated output signal. It’s simple to run a manual or automatic calibration check using known value gases to flow a calibration gas through the detector’s calibration gas port — without removing the detector from the process. The Zircomat transmitter can monitor and analyze performance of up to seven parameters online. Failure to meet any of these specifications will activate alarm contact. The self-cleaning probe feature is programmable from the keypad, and activates a solenoid valve for blow-back probe cleaning.You can use the interactive panel to customize response time to process changes to suit existing combustion control parameters. Looking for COSA portable combustion efficiency analyzers? Call Lesman. Selecting the Right Zircomat Analyzer System Specifications Sensor: Zirconia oxide Measurement Range: 0-2%, Up to 50% 0.5% steps Output Signal: 4-20 mA, linear isolated Accuracy: ±2% of reading; Repeatability: ±0.5% Response Time: Initial 0.1 sec./90% 7 sec; Warm Up Time: 5 minutes Probe Materials: ZFK/ZTB: Steel, ZTA: Carbide, ZFK-ST: Mullite Probe Flange: ZTB/ZFK/ZFK-ST: 4” 150#RF; ZTA: 2.5” 150#RF Cable: 20 ft. Sealtite flexible conduit, up to 1000 ft. optional Air Requirement: Self-Cleaning Probe: 15 SCFM, 40-120 PSI;ZTA Probe Sample Loop: 10-20 SCFH ZTA Probe: Low temperature alarm below 100°C, volt; free 1A 115V contact closure Transmitter Ambient Temperature: 0-130°F High/Low Alarms: Rated N/O volt free 2A 250V Contacts: Outputs: Rain resistant; Inputs: Autocal start/inhibit; Alarm: Failure in service, maintenance blow down Calibration: Manual or automatic Output Signal Hold: Selectable, for self-cleaning or maintenance Finish: Epoxy painted steel/SS Mounting: Wall, panel, or 2” pipe mount Options: Combustion efficiency, RS485 communication, remote calibration unit with solenoids and flow meter; Hazardous area transmitter Please issue all orders to: Cosa Instruments, c/o Lesman Instrument Company Fuel Type Gas or Oil Gas or Oil Coal, Oil, or Gas Coal, Oil, or Gas Sample Gas Up to 1150°F Up to 2200°F Up to 2900°F Up to 1150°F Available Probe Lengths 12, 20, 30, 40, 60, 80, 100, 120, 140 20, 40 20, 30, 40, 60 12, 20, 30, 40, 60, 80, 100, 120, 140 Applications Utility/Industrial Power Boilers, Process Heaters, Marine Boilers, Drying Furnaces, Steam Gener ators, Inert Gas Generators Process Heaters, Steam Generators, Power Boilers Soaking Pits, Blast Furnaces, Coke Ovens, Incinerators, Glass Furnaces, Boiler Fireboxes, Process Heaters, Reheat Furnaces Utility/Industrial Power Boilers, Incinerators, Blast Furnaces, Coke Ovens, Black Liquor Boilers Use Model... ZRM-ZFK ZRM-ZFK-ST ZRM-ZTA ZRM-ZTB Prices Start at... $4796.00 $4996.00 $7216.00 $5073.00 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 EFFICIENCY ANALYZER 29 Portable Combustion Efficiency Analyzers 866-RENT-EHS (866)736-8347 Our partners at RAECO make it easy to get the combustion efficiency analysis equipment you need, without a major outlay of cash. When you need portable combustion analyzers for short-term use, RAECO Rents! has units for daily, weekly, or monthly rental. So you get the best monitor/analyzer for your needs, just for the time you need it. No big purchase, no maintenance and upkeep costs. Call 866-736-8347 and ask for Patricia or Rick. Testo 330-2 Industrial Combustion Analyzer • Measures O2, CO, NO (CO2 and NOx calculated), temperature °F, pressure, efficiency, and excess air • Automatic sensor protection (CO dilution to 30,000 ppm); Automatic moisture protection; includes visual alarm and pump shut-off • Datalogs 200 measuring records, with address and system numbers • Infrared (IrDA) interface for working with a handheld PDA, infrared printer, or laptop PC, USB interface for configuration and data uploads Testo 330-2 Kit comes with 12" click-and-go probe, 7' hose, rechargeable Lithium Ion battery, charger with cord, infrared printer with paper, carrying strap, standard case with foam insert, USB cable, software, and user manual. Testo 335 Portable Flue Gas Analyzer • Measures O2, CO, NO draft, flow, velocity, mass, differential pressure • Automatic dilution expands CO range to 50000 ppm, NO to 6000 ppm • Pre-calibrated plug-and-play sensors eliminate the need for calibration gas in all but the most demanding applications • Datalogging for up to two hours • Infrared interface for printer, handheld PDA, or laptop PC Testo 335 NOx Kit comes with standard 12" probe, 7-foot Teflon®-lined hose, Type K thermocouple, sensors for NOx, O2, CO, and NO, infrared printer with 6 rolls of paper, power adapter with Lithium Ion battery, extra battery and charger, 10-pack of filters, Easy Emission software, USB cable, and standard case with foam insert. $100.00 Daily $250.00 Weekly $700.00 Monthly $3590.00 to Buy $123.00 Daily $410.00 Weekly $1025.00 Monthly $3795.00 to Buy Testo 350-XL Portable Emissions Analyzer Kit • • • • • • Sensors for O2, CO, NO, NO2 (NOx), SO2 Temperature-controlled sensors extend testing range Sample conditioning with Peltier gas chiller and water removal system Dilution system 40:1 max. extends CO range to well over 100,000 ppm Fresh air purge; Rapid set-up for easy measuring Large backlit display has multipage scroll-down, zoom function, and pulldown menus Testo 350-XL Engine Kit comes with gas sensors for CO, O2, NO, NO2 and SO2, control unit, particulate filters, printer paper, carrying case and strap, transport case with sliding drawer, 12" engine probe with 7' hose and 12" thermocouple probe with 16' cable, RS232 cable, software, and 16' remote control cable. $200.00 Daily $500.00 Weekly $1500.00 Monthly $8990.00 to Buy CA-Calc 6213 Combustion Analyzer for O2, CO, NO, SO2 • • • • Real-time measurement seconds after power-up Calculates efficiency, excess air, CO2, and emission rates, provides NO2 values Adjustable CO high limit pump shutdown; Adjustable O2 reference Data history sorted by system, or individual sample for printouts and report generation CA-Calc 6213 includes 12” probe with 9-foot sampling tube, Teflon-lined sampling probe, water trap, carrying case, AC adapter, four C Alkaline batteries, and operation manual. $100.00 Daily $200.00 Weekly $700.00 Monthly COMBUSTIBLE GAS MONITORS V 10.2008 30 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 Portable Combustible Gas Detectors from 866-RENT-EHS (866)736-8347 Choosing the Right Combustible Gas Detector for Your Application Alarms Product Visible Audible Vibrating STEL TWA Honeywell ImpactPro ✔ ✔ ✔ ✔ MSA Altair 4 ✔ ✔ ✔ MSA Orion ✔ ✔ ✔ ✔ MSA Solaris ✔ ✔ ✔ ✔ MSA Passport PID II ✔ ✔ ✔ ✔ MSA Sirius ✔ ✔ ✔ ✔ Data Infrared Intrinsically Logging Port Safe ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Honeywell Impact Pro Multigas Monitor • Simultaneously monitors and displays readings for O2, CO, H2S, and %LEL • Three levels of instantaneous alarm, plus time-weighted average alarms on toxic gases • Base station combines functionality of data interface and battery charging • Event and timed data logging Impact Pro kit includes sensors for CO, O2, H2S, and LEL; integral pump and pump adapter, charger with charging base, rechargeable NiMH batteries, belt clip, flow adapter, 30' sample tube with inline adapter, ball float, base station PC link cable, software CD, quick-start guide, user manual, and carrying case. Honeywell Enforcer Calibrator for Impact Pro • Calibrates Honeywell Impact Pro multigas monitors fitted with oxygen, flammable, carbon monoxide, and hydrogen sulfide sensors • Records calibration results for printing via PC software • Built-in indicator tells you when gas cylinder needs replacing • Recognizes Impact Pro immediately, and completes tests and calibration in less than two minutes Enforcer kit includes one multigas cylinder, wall-mount plate, and carrying case. MSA Altair4 Multigas Detector with Pump Probe • High-contrast LCD shows simultaneous readings for LEL, CO, H2S, and O2 • Ultra-bright LEDs, 95 dB horn, and vibrating alarms for warnings you can't miss! • MotionAlert signals "man down" by detecting lack of motion for 30 seconds, InstantAlert lets you sound a manual alarm to warn others of hazards • 16-hour battery run time when fully charged Save 20% off the price listed purchase ables rt po SA M on all before when you buy ! 12/31/2008 a Call for pricing onel od m d se gently-u Altair 4 kit includes detector with universal pump probe, sensors for 0-100% Pentane LEL, 0-25% O2, 0-999 ppm CO, and 0-200 ppm H2S, power supply/charger, MSA-Link software CD-ROM, JetEye infrared adapter with USB connector, user manual, and carrying case. Weekly Rental Price 100.00 125.00 100.00 125.00 250.00 350.00 $40.00 Daily $100.00 Weekly $350.00 Monthly $1304.00 to Buy $15.00 Daily $42.00 Weekly $105.00 Monthly $268.00 to Buy $40.00 Daily $125.00 Weekly $300.00 Monthly $1239.00 to Buy Passport® PID II Personal Organic Vapor Monitor • • • • • Range 0–10,000 ppm with no dilution tube or internal adjustment Peak, short-term exposure (STEL) and time-weighted average (TWA) 69 pre-programmed and 10 user-defined response factors Digital display shows numeric and bargraph detail of VOC concentration 5-second access to change battery pack, clean or replace lamp Passport PID II includes NiCad battery pack, 110 VAC charger, 10' coiled Teflon sampling line, PVC case, protective rubber boot, pistol grip with wrist strap, and 8" screw-on probe. $50.00 Daily $250.00 Weekly $700.00 Monthly Save 20% off the price listed purchase ables rt po SA on all M before when you buy ! 12/31/2008 Lesman Instrument Company www.lesman.com sales@lesman.com Wisconsin, and Upper Peninsula Michigan Phone: 800-837-1700 • 262-923-1790 Fax: 262-923-1797 V 10.2008 Illinois, Indiana, and Iowa Phone: 800-953-7626 • 630-595-8400 Fax: 630-595-2386 COMBUSTIBLE GAS MONITORS 31 Solaris Multigas Detector for Monitoring Combustible Gases • • • • • • 1-, 2-, 3-, and 4-gas configurations for O2, H2S, CO, and combustibles 100+ dB horn, super-bright LED, and vibrating alarm Large, easy-to-read alphanumeric digital display Lightweight unit; IP65 rated for superior protection against liquid/dust ingress One-button calibration with built-in logic Lithium Ion battery with runtime of 14+ hours Kit includes detector, battery charger, charging station, calibration cap, tubing, two male fittings, infrared reader, Solaris software, quick reference card and manual on CD. $40.00 Daily $125.00 Weekly $300.00 Monthly $1409.00 to Buy Sirius Multigas Detector for VOCs and Combustible Gases • One unit simultaneously monitors VOCs with low vapor pressures and measures for combustible, toxic, and oxygen-deficient atmospheres • PID sensor includes humidity resistance, stable zero readings, and fast response and clear times • Multidirectional visible LED alarm and audible horn alarm • Display shows combustible gas, CO, H2S, O2, %LEL, and VOCs with their character names, also includes battery life indicator • Interchangeable battery packs keep instrument running 24x7 Sirius kit includes PID lamp, 0-100% LEL, H2S, CO, and O2 sensors, power supply, AC adapter and battery charging unit, sample line and probe, carrying case, orange Cordura jacket with harness, and instructions. $100.00 Daily $350.00 Weekly $750.00 Monthly $3617.00 to Buy Orion™ Multigas Detector for LEL, CO, O2, and H2S • • • • • • • One-button calibration simplifies calibration, reduces training needs Large easy-to-read display for low light conditions and many angles Long-life durable sensors provide up to 50 times the silicone poison tolerance Zoom expands any portion of a graph to focus on an activity detail Software to view gases simultaneously or focus on one at a time Resistant to water/dust; Nylon case for use in tough environments Long-life battery provides up to 20 hours in the non-pump mode Orion kit includes pump module, sensors for %LEL pentane, O2, CO, and H2S, 10' sample line, 1' probe, NiMH battery pack, battery charger and cord, screwdriver, filters, hose adapter, manual, FiveStar™ Link software, carrying case, orange Cordura jacket, and integral PulseCheck pump. $50.00 Daily $100.00 Weekly $350.00 Monthly $2123.00 to Buy The new RAECO Rents instrumentation catalog is now available! Get yours FREE! • 64 pages of instrumentation for industrial hygiene, safety, and environmental applications • Rentals available on a daily, weekly, or monthly basis • All parts, accessories, and software available • Automatic 5% rental fee discount when you rent online at www.raeco.com Visit www.raeco.com to request a print catalog or download the free PDF. WE’RE WAITING! When you need Honeywell Burner Controls products fast, call Lesman. We stock a wide variety of popular items that can ship to you the same day. Need a Hand? Our applications specialists are factory-trained to help you through the installation and maintenance headaches of typical flame safety systems. See More at Lesman.com • Full specs and manuals on our burner and boiler controls product offering • Lots of articles, technical tips, and application success stories • Access to podcasts and video training • All available 24 hours a day, 7 days a week! 135 Bernice Drive • Bensenville, IL 60106-3366 Use Our Hotlines! Toll Free Local Phone Fax E-Mail Bensenville IL Butler WI 800-953-7626 800-837-1700 630-595-8400 262-923-1790 630-595-2386 262-923-1797 sales@lesman.com wisales@lesman.com Order by phone, fax, or e-mail for fast, friendly service. Prices are current as of publication date, and are subject to change without notice. Visit www.lesman.com/catupdates.html for catalog updates. Due to contractual agreements with our manufacturers, some items in this catalog may not be available in all geographic areas or markets.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Instance ID : uuid:bc66e151-f113-4c77-b6d1-bf5127433c25 Document ID : adobe:docid:indd:fb16ce9a-a6a4-11dd-b597-d5dfe5ef0279 Rendition Class : proof:pdf Derived From Instance ID : fb16ce99-a6a4-11dd-b597-d5dfe5ef0279 Derived From Document ID : adobe:docid:indd:fb16ce96-a6a4-11dd-b597-d5dfe5ef0279 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 600.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 200.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 200.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 600.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 600.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:5C2614C0A73111DD9C10872A98D6DF04, uuid:00F1DD1BA73911DD9C10872A98D6DF04, uuid:5DF43F78D26211DC9615F29052434E54, uuid:E2EADDD7692811DC8520C42567299A1F, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:2F9B5193A09911DAAAD597742AB3E2B6, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:168C6A1139E1DB118BA3BAE9347CE40B, uuid:B2CF4E0AA1C911DD9C10872A98D6DF04, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:90D40D64A75E11DD9C10872A98D6DF04, uuid:CC8EC2365FD611DDABFED848948A8195, uuid:B75CB552D25B11DC9615F29052434E54, uuid:5DF43F78D26211DC9615F29052434E54, uuid:E2EADDD7692811DC8520C42567299A1F, uuid:1C56B7155BD011DDABFED848948A8195, uuid:1C56B7155BD011DDABFED848948A8195, uuid:018C8855692711DC8520C42567299A1F, uuid:04987E05691F11DC8520C42567299A1F, uuid:B8980E9569DB11DC9EB0D24AC369C7DF, uuid:25337F0E5E5911DDABFED848948A8195, uuid:FCC5FD7A692A11DC8520C42567299A1F, uuid:E1923F0D8A5DDD1185F3A556FCBB1714, uuid:FCC5FD82692A11DC8520C42567299A1F, uuid:7D976E925F0B11DDABFED848948A8195, uuid:C7C26AA9A164DD119F33B7C4B6125898, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:DFE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BC490711DDA295E1591AFBB30E, uuid:7073AAF7491611DDA295E1591AFBB30E, uuid:7073AAFE491611DDA295E1591AFBB30E, uuid:BF6C16C65F1711DDABFED848948A8195, uuid:DC4FC983490911DDA295E1591AFBB30E, uuid:DFE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BC490711DDA295E1591AFBB30E, uuid:BF6C16C65F1711DDABFED848948A8195, uuid:7073AAF7491611DDA295E1591AFBB30E, uuid:7073AAFE491611DDA295E1591AFBB30E, uuid:855AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:4AFD5D435F1511DDABFED848948A8195, uuid:DC4FC983490911DDA295E1591AFBB30E, uuid:855AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:90D40D64A75E11DD9C10872A98D6DF04, uuid:AC16033275EF11DDB36D85190DDD8BB2, uuid:7DA1CB503875DD11B720DFA8642135E7, uuid:3C7F78A975C511DDB36D85190DDD8BB2, uuid:C10E2F069073DD11AA96AE50A3CCC39E, uuid:F181407075C311DDB36D85190DDD8BB2, uuid:DA41A970BA73DD11AA96AE50A3CCC39E, uuid:A16BEB3D3775DD11B720DFA8642135E7, uuid:DADECDE4691511DC8520C42567299A1F, uuid:04987DFD691F11DC8520C42567299A1F, uuid:E2967103DF46DD1194E8C3AACF87B638, uuid:21E72042692D11DC8520C42567299A1F, uuid:018C8850692711DC8520C42567299A1F, uuid:DAA0EDF269B711DC8520C42567299A1F, uuid:2D9AAF6D617A11DDA42197863AFDB069, uuid:DB344817922711DD8CA5963EBA562DF8, uuid:E40542DA558EDD118B3ED1334A9CAABB, uuid:E0D02CD7A29FDD11975AC1C5DB942EE2, uuid:63C992D2BA9FDD11975AC1C5DB942EE2, uuid:C66744C2A05A11DD9C10872A98D6DF04, uuid:2E04F26C999BDD118C1BD55B4C8FB448, uuid:C66744B9A05A11DD9C10872A98D6DF04, uuid:F232695D789CDD11BE5A991F6EAC47D5, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:51970E36B89BDD11BC25A8384338720B, uuid:F128B4CDC19BDD11BC25A8384338720B, uuid:A581BA1F849CDD11BE5A991F6EAC47D5, uuid:64EDB845999CDD11BE5A991F6EAC47D5, uuid:A76D579A9A9CDD11BE5A991F6EAC47D5, uuid:1BE0C39E33A5DD118E85E73DFEEC2D59, uuid:F932695D789CDD11BE5A991F6EAC47D5, uuid:C00121F9989CDD11BE5A991F6EAC47D5, uuid:66ABB29C649CDD11BE5A991F6EAC47D5, uuid:BD04C610C89BDD11BC25A8384338720B, uuid:0BAC91DE889CDD11BE5A991F6EAC47D5, uuid:AE6D579A9A9CDD11BE5A991F6EAC47D5, uuid:D45FABE1909CDD11BE5A991F6EAC47D5, uuid:9310C932689CDD11BE5A991F6EAC47D5, uuid:BC0215BB161C11DA8A62BC86F2DA420C, uuid:BAF335E18F5211DA8718BC7171BEF4C4, uuid:0FA6E2728F4A11DA8718BC7171BEF4C4, uuid:0FA6E2778F4A11DA8718BC7171BEF4C4, uuid:81E649048E7911DA8718BC7171BEF4C4, uuid:D6D37C0A161E11DA8A62BC86F2DA420C, uuid:9C9A1A298D91DD11ACFBC9ABC7238363, uuid:0C8219B0156111DAA5A0B8E1861C9D5D, uuid:19CBFB0FD979DD11A6B88BD67EA9365F, uuid:F5DFCBD8E979DD11A6B88BD67EA9365F, uuid:1F19D7BBD279DD11A6B88BD67EA9365F, uuid:1F19D7BBD279DD11A6B88BD67EA9365F, uuid:F5DFCBD8E979DD11A6B88BD67EA9365F, uuid:E52715C0E379DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:E52715C0E379DD11A6B88BD67EA9365F, uuid:5E17A03CF279DD11A6B88BD67EA9365F, uuid:EBDFCBD8E979DD11A6B88BD67EA9365F, uuid:D1AE57018970DD11B3B1CD7DD1EBDF2A, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:53B387B3CF79DD11A6B88BD67EA9365F, uuid:1919D7BBD279DD11A6B88BD67EA9365F, uuid:E7CBEFCE4775DD118543BFBDC6FBEAD1, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:3A9A314366D311DDAE54CA873A8B0032, uuid:A7942BD0A36D11DD9C10872A98D6DF04, uuid:2FF6E1A5ED79DD11A6B88BD67EA9365F, uuid:8F7F306EEF79DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:43169560388EDD119B72CDDEEF182957, uuid:6029C3A4C879DD11A6B88BD67EA9365F, uuid:4EB6352495EB11DD8CA5963EBA562DF8, uuid:C12E988244A111DA96B0C8D23C754193, uuid:0B8A17DE44A211DA96B0C8D23C754193, uuid:E2B5EF19449811DA96B0C8D23C754193, uuid:A52AA190AD2911DAAAD597742AB3E2B6, uuid:6C109C54AD2811DAAAD597742AB3E2B6, uuid:D6D37C12161E11DA8A62BC86F2DA420C, uuid:2F9B5193A09911DAAAD597742AB3E2B6, uuid:E3B06E2D431811DB908DFF8AD8E5CDAE, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:8C75B2BF4A32DD118057E4CEE7FEA81F, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:0899BE434E32DD118057E4CEE7FEA81F, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:168C6A1139E1DB118BA3BAE9347CE40B, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:D50E71DC3637DD11AB79A0FAC0AA5B32, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:A5B340B4B183DB11A056AFDD7106D967, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:1A6FF47CE637DD11A9CB82197BCCD2CE, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:8855672329FB11DBB05FF105C0E59095, uuid:cdbf23fb-43af-11d9-92ee-ed536a4eae7b, uuid:00717c24-43b0-11d9-92ee-ed536a4eae7b, uuid:00717c28-43b0-11d9-92ee-ed536a4eae7b, uuid:bdda5436-447f-11d9-b4be-cd2c075e24dd, uuid:3A9A314366D311DDAE54CA873A8B0032, uuid:5C2614CAA73111DD9C10872A98D6DF04, uuid:BD3E435AA1B611DD9C10872A98D6DF04, uuid:2EE33897AE48DB11AB63D359F1A4B3E8, uuid:D1AE57018970DD11B3B1CD7DD1EBDF2A, uuid:9A5A10B68A70DD11B3B1CD7DD1EBDF2A, uuid:72B74CE0A464DD119F33B7C4B6125898, uuid:A90922738970DD11B3B1CD7DD1EBDF2A Manifest Reference Document ID : uuid:A7942BDAA36D11DD9C10872A98D6DF04, uuid:3D16E9D0A73211DD9C10872A98D6DF04, uuid:06AEA9F3D26011DC9615F29052434E54, uuid:E2EADDD6692811DC8520C42567299A1F, uuid:4AFD5D425F1511DDABFED848948A8195, adobe:docid:photoshop:e2ad442e-b40e-11d9-88e0-9b9efc255ea5, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:1868D569FBC0DB1184D8EF70B6C6C624, adobe:docid:indd:459b3107-a1b3-11dd-b597-d5dfe5ef0279, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:dc3476f7-e861-494f-911d-d3370cb14edd, uuid:B75CB551D25B11DC9615F29052434E54, uuid:06AEA9F3D26011DC9615F29052434E54, uuid:E2EADDD6692811DC8520C42567299A1F, uuid:1C56B7145BD011DDABFED848948A8195, uuid:1C56B7145BD011DDABFED848948A8195, uuid:018C8854692711DC8520C42567299A1F, uuid:04987E04691F11DC8520C42567299A1F, uuid:E14AD12A692411DC8520C42567299A1F, uuid:25337F0D5E5911DDABFED848948A8195, uuid:FCC5FD79692A11DC8520C42567299A1F, uuid:E0923F0D8A5DDD1185F3A556FCBB1714, uuid:FCC5FD81692A11DC8520C42567299A1F, uuid:02B818895F0B11DDABFED848948A8195, uuid:C4C26AA9A164DD119F33B7C4B6125898, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:4AFD5D425F1511DDABFED848948A8195, uuid:DEE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BB490711DDA295E1591AFBB30E, uuid:5BF00460691711DC8520C42567299A1F, uuid:8E12E9D7AD47DD11BAF2C95D6B91BBB5, uuid:BF6C16C55F1711DDABFED848948A8195, uuid:DC4FC982490911DDA295E1591AFBB30E, uuid:DEE501489A47DD11871CFBBC135BCBA9, uuid:1D5041BB490711DDA295E1591AFBB30E, uuid:BF6C16C55F1711DDABFED848948A8195, uuid:5BF00460691711DC8520C42567299A1F, uuid:8E12E9D7AD47DD11BAF2C95D6B91BBB5, uuid:845AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:4AFD5D425F1511DDABFED848948A8195, uuid:DC4FC982490911DDA295E1591AFBB30E, uuid:845AB9DBAF47DD11BAF2C95D6B91BBB5, uuid:dc3476f7-e861-494f-911d-d3370cb14edd, uuid:356AABDA3175DD11B720DFA8642135E7, uuid:0B7FD0DB9273DD11AA96AE50A3CCC39E, uuid:C00E2F069073DD11AA96AE50A3CCC39E, uuid:BA0E2F069073DD11AA96AE50A3CCC39E, uuid:D941A970BA73DD11AA96AE50A3CCC39E, uuid:A06BEB3D3775DD11B720DFA8642135E7, uuid:DADECDDE691511DC8520C42567299A1F, uuid:04987DFC691F11DC8520C42567299A1F, uuid:E1967103DF46DD1194E8C3AACF87B638, uuid:21E72041692D11DC8520C42567299A1F, uuid:018C884F692711DC8520C42567299A1F, uuid:DAA0EDF169B711DC8520C42567299A1F, uuid:2D9AAF6C617A11DDA42197863AFDB069, uuid:EAF91A185A8EDD118B3ED1334A9CAABB, uuid:E30542DA558EDD118B3ED1334A9CAABB, uuid:a73d7e14-f605-4d5b-8656-c83acf2ba7f5, uuid:211ecefa-1025-4666-afbf-5be620c471d7, uuid:302e22ae-f859-4945-95d3-24cee3b3df1b, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:32934e88-2113-43d1-bae9-ec562538b6f4, uuid:1AE0C39E33A5DD118E85E73DFEEC2D59, uuid:eb98d019-bd67-4323-b7fd-35a88157c421, uuid:0d6f44a6-3ba0-44c2-8a36-f81d1880aba0, uuid:5c96255b-a938-4c38-8246-fa64074d2e1c, uuid:d66f0f3f-fad0-4e97-a412-db91b2ff184e, uuid:BC0215BA161C11DA8A62BC86F2DA420C, uuid:BAF335E08F5211DA8718BC7171BEF4C4, uuid:0FA6E2718F4A11DA8718BC7171BEF4C4, uuid:0FA6E2768F4A11DA8718BC7171BEF4C4, uuid:81E649038E7911DA8718BC7171BEF4C4, uuid:BC0215BE161C11DA8A62BC86F2DA420C, uuid:999A1A298D91DD11ACFBC9ABC7238363, uuid:38A02F8A14B911DAA5A0B8E1861C9D5D, uuid:18CBFB0FD979DD11A6B88BD67EA9365F, uuid:F4DFCBD8E979DD11A6B88BD67EA9365F, uuid:1E19D7BBD279DD11A6B88BD67EA9365F, uuid:1E19D7BBD279DD11A6B88BD67EA9365F, uuid:F4DFCBD8E979DD11A6B88BD67EA9365F, uuid:E42715C0E379DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:E42715C0E379DD11A6B88BD67EA9365F, uuid:5D16EC01F279DD11A6B88BD67EA9365F, uuid:EC2715C0E379DD11A6B88BD67EA9365F, uuid:CEAE57018970DD11B3B1CD7DD1EBDF2A, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:52B387B3CF79DD11A6B88BD67EA9365F, uuid:1819D7BBD279DD11A6B88BD67EA9365F, uuid:E6CBEFCE4775DD118543BFBDC6FBEAD1, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, adobe:docid:indd:fb72f998-6074-11dd-9cad-be3a80da5c82, uuid:6BA1B336A27D11DD9C10872A98D6DF04, uuid:7258CA0BED79DD11A6B88BD67EA9365F, uuid:8A7F306EEF79DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:b4828032-9f37-4df0-beaa-19586d86d89d, uuid:5F29C3A4C879DD11A6B88BD67EA9365F, uuid:5147B88A7F94DD11ADAFA4EA7FEBECD1, uuid:C12E988144A111DA96B0C8D23C754193, uuid:0B8A17DD44A211DA96B0C8D23C754193, uuid:E2B5EF18449811DA96B0C8D23C754193, uuid:6C109C57AD2811DAAAD597742AB3E2B6, uuid:D6D37C0D161E11DA8A62BC86F2DA420C, uuid:D6D37C11161E11DA8A62BC86F2DA420C, adobe:docid:photoshop:e2ad442e-b40e-11d9-88e0-9b9efc255ea5, uuid:E3B06E24431811DB908DFF8AD8E5CDAE, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:8B75B2BF4A32DD118057E4CEE7FEA81F, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:a956fcc8-cb86-11dc-aaf4-0016cb381051, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, uuid:1868D569FBC0DB1184D8EF70B6C6C624, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:D40E71DC3637DD11AB79A0FAC0AA5B32, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:A4B340B4B183DB11A056AFDD7106D967, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:indd:ab4ee364-1bd0-11da-a4f9-a9609467894b, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, uuid:8855672229FB11DBB05FF105C0E59095, adobe:docid:photoshop:cdbf23fa-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:cdbf23fe-43af-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:00717c27-43b0-11d9-92ee-ed536a4eae7b, adobe:docid:photoshop:bdda5435-447f-11d9-b4be-cd2c075e24dd, adobe:docid:indd:fb72f998-6074-11dd-9cad-be3a80da5c82, uuid:5C2614C9A73111DD9C10872A98D6DF04, uuid:BD3E4359A1B611DD9C10872A98D6DF04, uuid:2DE33897AE48DB11AB63D359F1A4B3E8, uuid:CEAE57018970DD11B3B1CD7DD1EBDF2A, uuid:02A24D2E8A70DD11B3B1CD7DD1EBDF2A, uuid:6FB74CE0A464DD119F33B7C4B6125898, uuid:A60922738970DD11B3B1CD7DD1EBDF2A Create Date : 2008:11:06 08:44:42-06:00 Modify Date : 2008:12:30 11:42:22-06:00 Metadata Date : 2008:12:30 11:42:22-06:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 22062 bytes, use -b option to extract) Format : application/pdf Title : Lesman "It's On Fire" Combustion Instrumentation Catalog Description : Combustion Creator : Beth Rose, Lesman Instrument Company Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 32 Subject : Combustion Author : Beth Rose, Lesman Instrument CompanyEXIF Metadata provided by EXIF.tools