Cooper O Technical Reference 3 Phase

User Manual: Cooper-O-Technical Reference-3-phase

Open the PDF directly: View PDF PDF.
Page Count: 30

DownloadCooper-O-Technical Reference-3-phase
Open PDF In BrowserView PDF
Table of Contents

Page

Page

NEMA Configurations

O-2

15A & 20A Straight Blade . . . . . . . . . . . . . . . . . . . . . . . . . . O-2
30A, 50A, & 60A Straight Blade . . . . . . . . . . . . . . . . . . . . . O-3
15A, 20A & 30A Locking . . . . . . . . . . . . . . . . . . . . . . . O-4–O-6
10A-30A Non-NEMA Locking . . . . . . . . . . . . . . . . . . . . . . . O-7
50A Non-NEMA Locking . . . . . . . . . . . . . . . . . . . . . . . . . . . O-7

Pin & Sleeve Configurations

O-8

20A Watertight Pin & Sleeve . . . . . . . . . . . . . . . . . . . . . . . . O-8
30A Watertight Pin & Sleeve . . . . . . . . . . . . . . . . . . . . . . . . O-8
60A Watertight Pin & Sleeve . . . . . . . . . . . . . . . . . . . . . . . . O-9
100A Watertight Pin & Sleeve . . . . . . . . . . . . . . . . . . . . . . . O-9

Horsepower Ratings

O-10

For NEMA Configurations (Plugs & Receptacles Only) . . . O-10

Common Industry Information

O-11

Organization Abbreviations Glossary . . . . . . . . . . . . . . . . O-11
Common Industry Organization Acronyms . . . . . . . . . . . . O-12
UL & CSA Standards For Wiring Devices . . . . . . . . . . . . . O-12
General Purpose Wiring Device Definitions . . . . . . . . . . . O-13
Select NEC® Requirements for Wiring Devices . . . . . . . . . O-14

Wire & Cable Information

O

SECTION

http://waterheatertimer.org/How-to-wire-240-volt-outlets.html
http://waterheatertimer.org/How-to-wire-3-phase-electric.html

Dimensional Data

O-21

Switch Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . O-21
Enclosure Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . O-22
Snap-In Receptacle Panel Cutouts . . . . . . . . . . . . . . . . . . O-23
Attachon Lampholder Panel Cutouts . . . . . . . . . . . . . . . . O-23

Switch Applications

O-24

Test Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-24
Maximum Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-25

Chemical Resistance of Materials

O-26

Properties of Common Materials in Wiring Devices . . . . . O-26

NEMA & IP Enclosures

O-27

Enclosure Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-27
Enclosure Type Cross Reference:
NEMA/UL/CSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-28–O-29

NAFTA Compliant

O-30

NAFTA Compliant Criteria . . . . . . . . . . . . . . . . . . . . . . . . . O-30

O-15

Wire & Cable Abbreviations. . . . . . . . . . . . . . . . . . . . . . . . O-15
Diameter Ranges of Jacketed Cord, per UL62 . . . . . . . . . O-15

Wiring Diagrams

O-16

By NEMA: 2-Pole, 2-Wire Non-Grounding . . . . . . . . . . . . O-16
By NEMA: 2-Pole, 3-Wire Grounding . . . . . . . . . . . . . . . . O-16
By NEMA: 3-Pole, 3-Wire Non-Grounding . . . . . . . . . . . . O-16
By NEMA: 3-Pole, 4-Wire Grounding . . . . . . . . . . . O-16–O-17
By NEMA: 4-Pole, 4-Wire Non-Grounding . . . . . . . . . . . . O-17
By NEMA: 4-Pole, 5-Wire Grounding . . . . . . . . . . . . . . . . O-17
Receptacles & GFCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-18
Combination Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-18
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-19
Manual Contactors & Disconnect Switches . . . . . . . . . . . O-20
Manual Contactors & Disconnect Switches,
by Motor Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O-20

www.arrowhart.com

Section O

Rating

125V/AC

Receptacle, Connector
& Flanged Outlet

1

4882 ★

5

2-Pole, 3-Wire Grounding

125V/AC

NEMA Prefix

2-Pole, Poles, Wires
2-Wire

NEMA Configurations For Select Devices

250V/AC

6

15A Straight Blade

AH5262 ■M
5252 ■
6262 ■D
IG5262 ■IM
5261 ✚M
VGF15 ■GM
BR15 ■
TRBR15 ■R
CR15 ■
TRVGF15 ■RGM
5262 ■M
AH8200 ■M
8200 ■HM
8210 ✚M
IG8200 ■IM
TR8200 ■RM
VGFH15 ■GM
TRVGFH15 ■RGM
AH5662 ■M
5661 ✚
IG5662 ■I
6662 ■D
826 ■
816 ✚
5662C ■
AH8600 ■M

20A Straight Blade

Plug &
Flanged Inlet

Receptacle, Connector
& Flanged Outlet

4862 ◆

5269N ★NC
5279C ●
5969BLK ★O
6269 ★L
4887 ★

5266N ◆NC
5278C ▲
6266 ◆
4867 ◆
5266NHG ◆N
6266HG ◆L
8115GY ◆O

AH5362 ■M
5352 ■M
6362 ■DM
IG5362 ■IM
5361 ✚M
VGF20 ■GM
BR20 ■
TRBR20 ■R
CR20 ■
TRVGF20 ■RGM
5362 ■M
AH8300 ■M
8300 ■M
8310 ✚M
IG8300 ■IM
TR8300 ■RM
VGFH20 ■GM
TRVGFH20 ■RGM

5269NHG ★N
6269HG ★L

5669N ★N
5679C ●
6669 ★L

5666N ◆N
5678C ▲
6666 ◆
4866 ◆
6665HG ◆L

AH5462 ■M
5461 ✚
IG5462 ■I
6462 ■D
815 ■
5462C ■
AH8400 ■M
IG8400 ■I

4227 ★
8610 ✚

5302 ■

4-Pole, 3-Pole, 4-Wire 3-Pole,
4-Wire
Grounding
3-Wire

277V/AC

Plug &
Flanged Inlet

5369N ★NC
5779C ●
6769 ★L

4228 ★

5366N ◆NC
5778C ▲
6766 ◆ L
4409 ◆
5366NHG ◆N
6766HG ◆L

5369NHG ★N
6769HG ★L

5469N ★N
5879C ●
6869 ★L
4229 ★

5466N ◆N
5878C ▲
6866 ◆L
4509 ◆
6865HG ◆AL

8410 ✚

7624N ◆L

7
805 ✚

125/250V/AC 10

9151N ◆L
2836 ◆

5759 ✚

125/250V/AC 14

3Ø 250V/AC 15
7251N ◆L

3ØY
18
120/208V/AC

Straight Blade Legend
Core catalog number color indicates a
devices’ grade:

BLACK = Industrial Specification Grade
BLUE = Commercial Specification Grade
ORANGE = Construction Specification Grade
GREEN = Hospital Specification Grade

A suffix combining a RED shape
and alpha letter indicate a
device's body, type and
available options.

Device body:

Device type:

Device options available:

HOW TO USE THIS CHART:

■ Duplex
Receptacle
✚ Single
Receptacle

◆
★
▲
●

Plug
Connector
Flanged Inlet
Flanged Outlet

A
D
G
H
I

Angled
Decorator
GFCI
Compact
Isolated Ground

L
N
O
R
S

Safety Grip™
AutoGrip™
QuickGrip™
Tamper Resistant
Surface

C Corrosion Resistant
M ArrowLink™ Modular

Due to spatial constraints not all products are shown on this page. For additional product options in these configurations consult sections A, B, G, H & I.

O-2

www.arrowhart.com

3-Pole, 3-Wire
3-Pole, 4-Wire
Grounding
4-Pole, 4-Wire

125V/AC

250V/AC

277V/AC

NEMA Prefix

Poles, Wires

125V/AC

2-Pole, 3-Wire Grounding

Rating

2-Pole,
2-Wire

NEMA Configurations For Select Devices
30A Straight Blade 50A Straight Blade 60A Straight Blade
Receptacle,
Connector &
Flanged Outlet

Plug &
Flanged Inlet

Receptacle,
Connector &
Flanged Outlet

Plug &
Flanged Inlet

Receptacle,
Connector &
Flanged Outlet

Plug &
Flanged Inlet

1

5

6

6716N ★N
1233 ✚
5716N ✚

5717AN ◆AN
5717N ◆N
5717NFI ▲N
S41 ◆A

6711N ★N
1253 ✚

5712AN ◆AN
5712N ◆N
5712NFI ▲N
S41 ◆A

6700N ★N
5700N ✚
1232 ✚S
1234 ✚

5701AN ◆AN
5701N ◆N
5701NFI ▲N
S42 ◆A

6709N ★N
5709N ✚
1252 ✚S
1254 ✚

5710AN ◆AN
5710N ◆N
5710NFI ▲N
S42 ◆A

6795N ★N
5795N ✚

5703AN ◆AN
5703N ◆N
5703NFI ▲N

6796N ★N

5705AN ◆AN
5705N ◆N
5705NFI ▲N

9341N ★N
38B ✚
125 ✚S

9352AN ◆AN
9337N ◆N
9337NFI ▲N
S80 ◆A

4526N ★N
7985N ✚
32B ✚
112 ✚S
122B ✚

4524N ◆N
4524NFI ▲N
7952AN ◆AN
S80 ◆A

5744N ✚
1225 ✚S
1257 ✚

5732AN ◆AN
5746N ◆N
S21 ◆A

5754N ✚
1212 ✚S
1258 ✚

5752AN ◆AN
5745N ◆N
S21 ◆A

9460N ✚

9462AN ◆AN
9462N ◆N
S20 ◆AN

8430N ✚

8432AN ◆AN
8432N ◆N

8450N ✚

8452AN ◆AN
8452N ◆N

8460N ✚

AH8462AN ◆AN
AH8462N ◆N

8352AN ◆AN
8352N ◆N

5515N ✚

4516AN ◆N
5517N ◆N
S19 ◆A

7

125/250V/AC 10

125/250V/AC 14

3Ø 250V/AC 15

8332AN ◆AN
8332N ◆N

3ØY
18
120/208V/AC

Straight Blade Legend
HOW TO USE THIS CHART:
Core catalog number color indicates a
devices’ grade:

◆
★
▲
●

Plug
Connector
Flanged Inlet
Flanged Outlet

A
D
G
H
I

Angled
Decorator
GFCI
Compact
Isolated Ground

A suffix combining a RED shape
and alpha letter indicate a
device's body, type and
available options.

Device options available:

Device type:

Device body:
■ Duplex
Receptacle
✚ Single
Receptacle

BLACK = Industrial Specification Grade
BLUE = Commercial Specification Grade
ORANGE = Construction Specification Grade
GREEN = Hospital Specification Grade
L
N
O
R
S

Safety Grip™
AutoGrip™
QuickGrip™
Tamper Resistant
Surface

C Corrosion Resistant
M ArrowLink™ Modular

Due to spatial constraints not all products are shown on this page. For additional product options in these configurations consult sections A, B, G, H & I.

www.arrowhart.com

O-3

Rating

NEMA
Prefix

2-Pole, 2-Wire

Poles,
Wires

NEMA Configurations For Select Devices

125V/AC

ML1

125V/AC

L1

250V/AC

L2

125V/AC

ML2

2-Pole, 3-Wire Grounding

125V/AC

250V/AC

277V/AC

L5

L6

L7

Receptacle, Connector
& Flanged Outlet

20A Locking

Plug &
Flanged Inlet

7464N ★
7427N ★
7468 ●

7465N
7428N
7479N
7429N

CWL115FO ●
CWL115R ✚
7506 ★
7540 ■

CWL115FI ▲
7546 ◆
7548 ◆

◆
◆
◆
◆

Receptacle, Connector
& Flanged Outlet

CWL220C ★L
CWL220FO ●
CWL220R ✚
7593 ★
7596 ●
7596N ●

Plug &
Flanged Inlet

7466 ▲
7467 ▲

CWL220P ◆L
CWL220P-6 ◆ZL

7594 ◆
7595 ▲
7595N ▲

CWL515C ★L
CWL515FO●
IG4700 ■I
25W47 ★W
65W47 ✚W
CR4700 ■C
4731N ★N
4731NCR ★CN

CWL515CAN ★AL
CWL515R ✚
IGL515R ✚I
2547 ★Y
65W47DPLX ■W
4700 ■
5792 ■
CR5792 ■C

CWL515FI ▲
CWL515P ◆L
CWL515PAN ◆AL
24W47 ◆W
2447 ◆Y
4721N ◆N
4721NCR ◆CN

CWL520C ★L
CWL520FO ●
IGL520R ✚I
L520CW ★W
L520CY ★Y
L520RW ✚W
CRL520C ★CL
CRL520R ✚C

CWL520CBK ★L
CWL520R ✚

CWL520FI ▲
CWL520P ◆L
CWL520PBK ◆L
L520PW ◆W
L520PY ◆Y
CRL520P ◆CL

CWL615C ★L
CWL615R ✚
IGL615R ✚I
2549 ★Y
65W49DPLX ■W
6566N ★N
6580 ■

CWL615FO ●
25W49 ★W
65W49 ✚W

CWL615FI ▲
CWL615P ◆L
24W49 ◆W
2449 ◆Y
6565N ◆N

CWL620C ★L
CWL620R ✚
L620CW ★W
L620RW ✚W
CRL620R ✚C
CRL620C ★CL

CWL620FO ●
IGL620R ✚I
L620CY ★Y

CWL620FI▲
CWL620P ◆L
L620PW ◆W
L620PY ◆Y
CRL620P ◆C

CWL715C ★
CWL715R ✚
25W34 ★W
65W34 ✚W
4772N ★N

CWL715FO ●
65W34DPLX ■W
4750 ■
2534 ★Y

CWL715FI ▲
CWL715P ◆L
24W34 ◆W
2434 ◆Y
4771N ◆N

CWL720C ★L
CWL720FO ●
CWL720R ✚
IGL720R ✚I
L720CW ★W
L720CY ★Y
L720RW ✚W

480V/AC

L8

CWL820C ★L
CWL820R ✚
L820CW ★W
L820CY ★Y
L820RW ✚W

600V/AC

L9

CWL920C ★
CWL920FO ●
CWL920R ✚

125/250V/AC ML3

3-Pole, 3-Wire

15A Locking

7484 ★
7487 ●
7487N ●

CWL720FI▲
CWL720P ◆L
L720PW ◆W
L720PY ◆Y

CWL820FO ●
IGL820R ✚I

CWL820FI ▲
CWL820P ◆L
L820PW ◆W
L820PY ◆Y
CWL920FI ▲
CWL920P ◆

7485 ◆
7486 ▲
7486N ▲

125/250V/AC L10

3Ø 250V/AC L11

CWL1020C ★L
CWL1020R ✚
L1020CY ★Y
L1020RW ✚W
L1020CW ★W

CWL1020FO ●

CWL1020FI ▲
CWL1020P ◆L
L1020PW ◆W
L1020PY ◆Y

CWL1120C ★L
CWL1120R ✚
L1120CY ★Y
L1120RW ✚W

CWL1120FO ●
L1120CW ★W

CWL1120FI ▲
CWL1120P ◆L
L1120PW ◆W
L1120PY ◆Y

CWL1220C ★
CWL1220FO ●
CWL1220R ✚

3Ø 480V/AC L12

CWL1220FI ▲
CWL1220P ◆

3Ø 600V/AC L13

Locking Device Legend
HOW TO USE THESE
CHARTS:
Core catalog number
color indicates the type
of use a device is
designed for:

A suffix combining a
RED shape and alpha
letter indicate a device’s
body and type.

Device body:
■
✚
◆
★
▲
●

Duplex Receptacle
Single Receptacle
Plug
Connector
Flanged Inlet
Flanged Outlet

BLACK = Industrial Use

O-4

www.arrowhart.com

Device type:
A
C
I
L
N

Angled
Corrosion Resistant
Isolated Ground
Safety Grip™
AutoGrip™

P
W
Y
Z

Pro-Grip™ Nylon
Watertight
Sever Duty Insulated
With Lid or Cover

2-Pole, 2-Wire

Rating

125V/AC

ML1

125V/AC

L1

250V/AC

L2

125V/AC

ML2

2-Pole, 3-Wire Grounding

125V/AC

250V/AC

277V/AC

480V/AC

30A Locking

NEMA
Prefix

Poles,
Wires

NEMA Configurations For Select Devices

L5

Receptacle, Connector,
& Flanged Outlet

CWL530FO ●
CWL530R ✚
L530CW ★W
L530RW ✚W
CRL530C ★CL
CRL530R ✚C

L6

CWL630C ★L
CWL630R ✚C
L630CW ★W
L630RW ✚W
CRL630C ★CL
CRL630R ✚C

L7

CWL730C ★L
CWL730R ✚
L730CW ★W
L730CY ★Y
L730RW ✚W

L8

CWL830C ★L
CWL830R ✚
L830CW ★W
L830CY ★Y
L830RW ✚W

Plug & Flanged Inlet

CWL530C ★L
IGL530R ✚I
L530CY ★Y

CWL530FI ▲
CWL530P ◆L
IGL530P ◆IL
L530PW ◆W
L530PY ◆Y
CRL530P ◆CL

CWL630FO ●
IGL630R ✚I
L630CY ★Y

CWL630FI ▲
CWL630P ◆L
L630PW ◆W
L630PY ◆Y
CRL630P ◆CL

CWL730FO ●
IGL730R ✚I

CWL730FI ▲
CWL730P ◆L
L730PW ◆W
L730PY ◆Y

CWL830FO ●
IGL830R ✚I

CWL830FI ▲
CWL830P ◆L
L830PW ◆W
L830PY ◆Y

CWL930C ★
CWL930FO ●
CWL930R ✚

CWL930FI ▲
CWL930P ◆

CWL1030C ★L
CWL1030R ✚
L1030CW ★W
L1030CY ★Y
L1030RW ✚W
CWL1030FO ●

CWL1030FI ▲
CWL1030P ◆L
L1030PW ◆W
L1030PY ◆Y

CWL1130C ★
CWL1130R ✚
L1130CW ★W
L1130CY ★Y
L1130RW ✚W
CWL1130FO ●

CWL1130FI ▲
CWL1130P ◆L
L1130PW ◆W
L1130PY◆Y

3Ø 480V/AC L12

CWL1230C ★
CWL1230FO ●
CWL1230R ✚

CWL1230FI ▲
CWL1230P ◆

3Ø 600V/AC L13

CWL1330C ★
CWL1330FO ●
CWL1330R ✚

CWL1330FI ▲
CWL1330P ◆

600V/AC

L9

125/250V/AC ML3

3-Pole, 3-Wire

125/250V/AC L10

3Ø 250V/AC L11

For NEMA Configurations L-14
through L-24, see page O-6

Locking Device Legend
HOW TO USE THESE
CHARTS:
Core catalog number
color indicates the type
of use a device is
designed for:

A suffix combining a
RED shape and alpha
letter indicate a device’s
body and type.

Device body:
■
✚
◆
★
▲
●

Duplex Receptacle
Single Receptacle
Plug
Connector
Flanged Inlet
Flanged Outlet

Device type:
A
C
I
L
N

Angled
Corrosion Resistant
Isolated Ground
Safety Grip™
AutoGrip™

W Watertight
Y Severe Duty Insulated

BLACK = Industrial Use

www.arrowhart.com

O-5

Rating

NEMA
Prefix

Poles,
Wires

NEMA Configurations

3-Pole, 4-Wire Grounding

125/250V/AC L14

3Ø 250V/AC L15

3Ø 480V/AC L16

20A Locking
Receptacle, Connector
& Flanged Outlet
CWL1420C ★L
CWL1420FO ●
IGL1420R ✚I
L1420CW ★W
CRL1420C ★CL
CRL1420R ✚C
6406BK ●

CWL1420CBK ★L
CWL1420R ✚
L1420CY ★Y
L1420RW ✚W

CWL1520C ★L CWL1520FO ●
IGL1520R ✚I
CWL1520R ✚
L1520CY ★Y
L1520CW ★W
L1520RW ✚W
CRL1520C ★CL
CRL1520R ✚C
CWL1620CBK ★L
CWL1620C ★L
CWL1620R ✚
CWL1620FO ●
IGL1620R ✚I
L1620CW ★W
L1620CY ★Y
L1620RW ✚W
CRL1620C ★CL

4-Pole, 4-Wire

Receptacle, Connector,
& Flanged Outlet

Plug &
Flanged Inlet

CWL1420FI ▲
CWL1420P ◆L
CWL1420PBK ◆L
L1420PW ◆W
L1420PY ◆Y
CRL1420P ◆CL
6405BK ▲

CWL1430C ★L CWL1430FO ●
CWL1430R ✚
IGL1430R ✚I
L1430CW ★W
L1430CY ★Y
L1430RW ✚W
CRL1430C ★CL
CRL1430R ✚C

CWL1430FI ▲
CWL1430P ◆L
L1430PW ◆W
L1430PY ◆Y
CRL1430P ◆CL
6512BK ◆

CWL1520FI ▲
CWL1520P ◆L
L1520PW ◆W
L1520PY ◆Y
CRL1520P ◆CL

CWL1530C ★L
CWL1530R✚
L1530CW ★W
L1530CY ★Y
L1530RW ✚W
CRL1530C ★CL
CWL1630C ★L
CWL1630FO ●
CWL1630R ✚
L1630CW ★W
L1630CY ★Y
L1630RW ✚W

CWL1530FO ●
IGL1530R ✚I

CWL1530FI ▲
CWL1530P ◆L
L1530PW ◆W
L1530PY ◆Y
CRL1530P ◆CL

CWL1730C ★L
CWL1730R ✚
L1730CW ★W
L1730CY ★Y
L1730RW ✚W

CWL1730FO ●

CWL1730FI ▲
CWL1730P ◆L
L1730PW ◆W
L1730CY ◆Y

CWL1620P ◆L
CWL1620PBK ◆L
L1620PW ◆W
L1620PY ◆Y
CRL1620P ◆CL
CWL1620FI ▲

3Ø 600V/AC L17

CWL1630FI ▲
CWL1630P ◆L
L1630PW ◆W
L1630PY ◆Y
CRL1630P ◆CL

CWL1820C ★L
CWL1820R ✚
L1820CW ★W
L1820CY ★Y
L1820RW ✚W

CWL1820FO ●

CWL1820FI ▲
CWL1820P ◆L
L1820PW ◆W
L1820PY ◆Y

CWL1830C ★L
CWL1830R ✚
L1830CW ★W
L1830CY ★Y
L1830RW ✚W

CWL1830FO ●

3ØY
120/208V/AC L18

CWL1830FI ▲
CWL1830P ◆L
L1830PW ◆W
L1830PY ◆Y

CWL1920FO ●

CWL1920FI ▲
CWL1920P ◆L
L1920PW ◆W
L1920PY ◆Y

CWL1930C ★L
CWL1930R ✚
L1930CW ★W
L1930CY ★Y
L1930RW ✚W

CWL1930FO ●

3ØY
277/480V/AC L19

CWL1920C ★L
CWL1920R ✚
L1920CW ★W
L1920CY ★W
L1920RW ✚W

CWL1930FI ▲
CWL1930P ◆
L1930PW ◆W
L1930PY ◆Y

CWL2020C★L
CWL2020R✚
L2020CW ★W
L2020CY ★Y
L2020RW ✚W

CWL2020FO ●

CWL2020FI ▲
CWL2020P◆L
L2020PW ◆W
L2020PY ◆Y

CWL2030C ★L
CWL2030R ✚
L2030CW ★W
L2030CY ★Y
L2030RW ✚W

CWL2030FO ●

CWL2030FI ▲
CWL2030P ◆L
L2030PW ◆W
L2030PY ◆Y

CWL2120CBK ★L
CWL2120R ✚
L2120CF ★L

CWL2120FI ▲
CWL2120P◆L
CWL2120PBK ◆L
L2120PW ◆W
L2120PY ◆Y
L2120PF ◆L

CWL2130C ★L
CWL2130R✚
L2130CW ★W
L2130CY ★W
L2130RW ✚W
L2130CF ★L

CWL2130FO ●
IGL2130R ✚I

3ØY
120/208V/AC L21

CWL2120C ★L
CWL2120FO ●
IGL2120R ✚I
L2120CW ★W
L2120CY ★Y
L2120RW ✚W

CWL2130FI ▲
CWL2130P ◆L
L2130PW ◆W
L2130PY ◆Y
L2130PF ◆L

CWL2220C ★L
CWL2220R ✚
IGL220R ✚I
L2220CW ★W
L2220CY ★Y
L2220RW ✚W

CWL2220FO ●

3ØY
277/480V/AC L22

CWL2220FI ▲
CWL2220P ◆L
L2220PW ◆W
L2220PY ◆Y

CWL2230C ★L
CWL2230R ✚
IGL2230R ✚I
L2230CW ★W
L2230CY ★Y
L2230RW ✚W

CWL2230FO ●
L22230CF ★L

CWL2230FI ▲
CWL2230P ◆L
L2230PW ◆W
L2230PY ◆Y
L2230PF ◆L

CWL2320FO ●

CWL2320FI ▲
CWL2320P ◆L
L2320PW ◆W
L2320PY ◆Y

CWL2330C ★L
CWL2330R ✚
IGL2330R ✚I
L2330CW ★W
L2330CY ★Y
L2330RW ✚W

CWL2330FO ●

3ØY
347/600V/AC L23

CWL2320C ★L
CWL2320R ✚
IGL2320R ✚I
L2320CW ★W
L2320CY ★Y
L2320RW ✚W

CWL2330FI ▲
CWL2330P ◆L
L2330PW ◆W
L2330PY ◆Y

3ØY
347/600V/AC L20

4-Pole, 5-Wire
Grounding

30A Locking

Plug &
Flanged Inlet

Locking Device Legend
HOW TO USE THESE
CHARTS:
Core catalog number
color indicates the type
of use a device is
designed for:

A suffix combining a
RED shape and alpha
letter indicate a device’s
body and type.

Device body:
■
✚
◆
★
▲
●

Duplex Receptacle
Single Receptacle
Plug
Connector
Flanged Inlet
Flanged Outlet

BLACK = Industrial Use

O-6

www.arrowhart.com

Device type:
A
C
I
L
N

Angled
Corrosion Resistant
Isolated Ground
Safety Grip™
AutoGrip™

W Watertight
Y Severe Duty Insulated

10/15A
125/250V/AC

Receptacle,
Connector,
& Flanged Outlet
4755 ★L
7565N ★N
7580 ■
7582 ✚

Plug &
Flanged Inlet

CU

3-Pole, 3-Wire

7310B ✚
7314C ★L
7314CW ★W
7314CY ★Y
7314RW ✚W
7328N ●

Plug
Non-NEMA

7327N ▲
9965C ◆L
9965PW ◆W
9965PY ◆Y

X

X

W
Y

3330-2 ✚
3333CW ★W
3333CY ★Y
3333RW ✚W
3333N ★L
3336N ●

4-Pole, 4-Wire

480V/AC
California
Standard
125/250V/AC
Marine
Corrosion
Resistant

X

X

W
Y

7409N ●
7410B ✚
7413C ★L
7413CW ★W
7413CY ★Y
7413RW ✚W

Y

Plug
Non-NEMA

7408N ▲
7411C ◆L
7411PW ◆W
7411PY ◆Y
X

X
W

Y

W

Y

Z

Z

Receptacle
Non-NEMA

Plug
Non-NEMA

3430 ✚
3433CW ★W
3433CY ★Y
3433N ★L
3433RW ✚W
3436N ●

3431N ◆L
3431PW ◆W
3431PY ◆Y
3434N ▲
X

X
Y

W

W

Y

Z

Z

Receptacle
Non-NEMA

Plug
Non-NEMA

3523BK ★L
3525BK ●

4-P, 5-W
Grounding

250V/DC
600V/AC

Plug
Non-NEMA

Receptacle
Non-NEMA

30A 3Ø
120/208V/AC

250V/AC
California
Standard

3331N ◆L
3331PW ◆W
3331PY ◆Y
3337N ▲

W

20A 3Ø
120/208V/AC

W

125V/AC
California
Standard

Y

Receptacle
Non-NEMA

30A
125/250V/AC

G

CU

Receptacle
Non-NEMA

20A
125/250V/AC

125V/AC
Marine
Corrosion
Resistant

4767 ◆L
4767AN ◆AL
7567N ◆N

G

Rating

2-Pole, 3-Wire Grounding

Rating

50A Non-NEMA Locking

Poles,
Wires

10A - 30A
Non-NEMA Locking

3-Pole, 4-Wire Grounding

Poles, Wires

NEMA Configurations

125/250V/AC
California
Standard
3Ø 250V/AC
California
Standard

250V/DC
600V/AC

Plug, Flanged Inlets
& Hull Inlet

63CR60EX ★P
63CR60 ★T
63CR70 ✚

63CR61EX ◆P
63CR61 ◆T
G

CS6360EX ★P
CS6360 ★T
CS6370 ✚

G

Receptacle
Non-NEMA
5
G
W

CS8264EX ★P
CS8264 ★T
CS8269 ✚

Receptacle
Non-NEMA
5
X
G

Y

Y

G

Y
Z

X

Z

W

X
W

Receptacle
Non-NEMA

G

Plug
Non-NEMA

3Ø 480V/AC
California
Standard

G
W

Plug
Non-NEMA
5

CS8265EX ◆P
CS8265 ◆T
CS8275 ▲
CS8277 ▲Z

X

3762EX ★P
3762 ★T
3771 ✚

X

Y

CS8464EX ★P
CS8464 ★T
CS8469 ✚

Receptacle
Non-NEMA
5

63CR64EX ★P
63CR64 ★T
63CR69 ✚

X

Receptacle
Non-NEMA
5

G

Y
X

G

W

Receptacle
Non-NEMA
5
Y
X

Z

G

Y
X

7764EX ★P
7764 ★T
7379 ✚

Z

G

Z
Y

G

CS8164EX ★P
CS8164 ★T
CS8169 ✚

X

Z
G

Y

Y

Plug
Non-NEMA
5
Y

W

Receptacle
Non-NEMA
5

3764EX ★P
3764 ★T
3769 ✚

G
X

63CR65EX ◆P
63CR65 ◆T
G

Receptacle
Non-NEMA

CS6364EX ★P
CS6364 ★T
CS6369 ✚

Y

Plug
Non-NEMA
5

Y
X

CS8364EX ★P
CS8364 ★T
CS8369 ✚

G
X

CS8465EX ◆P
CS8465 ◆T
CS8475 ▲
CS8477 ▲Z

G

Y

Plug
Non-NEMA
5

3763EX ◆P
3763 ◆T
3777 ▲
3767 ▲Z

G

G

Y

Recptacle
Non-NEMA

CS6365EX ◆P
CS6365 ◆T
CS6375 ▲
CS6376 ▲Z

CS8365EX ◆P
CS8365 ◆T
CS8375 ▲
CS8377 ▲Z

3765EX ◆P
3765 ◆T
3775 ▲
3768 ▲Z

7765EX ◆P
7765 ◆T
7958 ▲
7968 ▲Z

Receptacle
Non-NEMA

20/10A
250/600V/AC

Plug
Non-NEMA
5

CS6361EX ◆P
CS6361 ◆T
CS6377 ▲
CS6378 ▲Z

Receptacle
Non-NEMA

250V/DC
600V/AC

3521BK ◆L
3524BK ▲

Receptacle &
Connector

X

CS8165EX ◆P
CS8165 ◆T
CS8175 ▲
CS8177 ▲Z

Receptacle
Non-NEMA

X

W

Plug
Non-NEMA
5
Y
G

X

W

Plug
Non-NEMA
5
Y
G

X

Z

Plug
Non-NEMA
5
Y
G

X

Z

Plug
Non-NEMA
5
Z
Y

X

G

Plug
Non-NEMA
5
Z
X

Y

G

Plug
Non-NEMA

Locking Device Legend
HOW TO USE THESE
CHARTS:
Core catalog number
color indicates the type
of use a device is
designed for:
BLACK = Industrial Use

A suffix combining a
RED shape and alpha
letter indicate a device’s
body and type.

Device body:
■
✚
◆
★
▲
●
◗

Duplex Receptacle
Single Receptacle
Plug
Connector
Flanged Inlet
Flanged Outlet
Hull Inlet

www.arrowhart.com

Device type:
A
C
L
N

Angled
Corrosion Resistant
Safety Grip™
AutoGrip™

P
T
W
Y
Z

Pro-Grip™ Nylon
Armored Body
Watertight
Severe Duty Insulated
With Lid or Cover

O-7

4-Pole, 5-Wire Grounding

3-Pole, 4-Wire Grounding

2-Pole, 3-Wire Grounding

Poles, Wires

Pin & Sleeve Configurations
20A Watertight
Pin & Sleeve

Rating

Receptacle, Connector
& Mechanical Interlocks

30A Watertight
Pin & Sleeve
Receptacle, Connector
& Mechanical Interlocks

Plug & Inlet

Plug & Inlet

CD320HMI4W ➤QX
CD320R4W ✚
CD320C4W ★

CD320P4W ◆
CD320B4W ▲

CD330MI4W ➤Q
CD330R4W ✚
CD330C4W ★

CD330P4W ◆
CD330B4W ▲

CD320HMI6W ➤QX
CD320R6W ✚
CD320C6W ★

CD320P6W ◆
CD320B6W ▲

CD330MI6W ➤Q
CD330MIF6W ➤E
CD330R6W ✚
CD330C6W ★

CD330P6W ◆
CD330B6W ▲

CD320P7W ◆
CD320B7W ▲

CD330MI7W ➤Q
CD330R7W ✚
CD330C7W ★

CD330P7W ◆
CD330B7W ▲

480V/AC

CD320HMI7W ➤QX
CD320R7W ✚
CD320C7W ★

CD420P12W ◆
CD420B12W ▲

CD430MI12W ➤Q
CD430MIB12W ➤F
CD430MICB12W ➤B
CD430MIF12W ➤E
CD430R12W ✚
CD430C12W ★

CD430P12W ◆
CD430B12W ▲

125/250V/AC

CD420HMI12W ➤QX
CD420MIB12W ➤F
CD420MICB12W ➤B
CD420R12W ✚
CD420C12W ★

CD420P9W ◆
CD420B9W ▲

CD430MI9W ➤Q
CD430MIB9W ➤F
CD430MICB9W ➤B
CD430MIF9W ➤E
CD430R9W ✚
CD430C9W ★

CD430P9W ◆
CD430B9W ▲

3Ø 250V/AC

CD420HMI9W ➤QX
CD420MIB9W ➤F
CD420MICB9W ➤B
CD420R9W ✚
CD420C9W ★

CD420P7W ◆
CD420B7W ▲

CD430MI7W ➤Q
CD430MIB7W ➤F
CD430MICB7W ➤B
CD430MIF7W ➤E
CD430R7W ✚
CD430C7W ★

CD430P7W ◆
CD430B7W ▲

3Ø 480V/AC

CD420HMI7W ➤QX
CD420MIB7W ➤F
CD420MICB7W ➤B
CD420R7W ✚
CD420C7W ★

CD420P5W ◆
CD420B5W ▲

CD430MI5W ➤Q
CD430MIF5W ➤E
CD430R5W ✚
CD430C5W ★

CD430P5W ◆
CD430B5W ▲

3Ø 600V/AC

CD420HMI5W ➤QX
CD420R5W ✚
CD420C5W ★

CD520HMI9W ➤QX
CD520R9W ✚
CD520C9W ★

CD520P9W ◆
CD520B9W ▲

CD530MI9W ➤Q
CD530MIB9W ➤F
CD530MICB9W ➤B
CD530R9W ✚
CD530C9W ★

CD530P9W ◆
CD530B9W ▲

CD520R7W ✚
CD520C7W ★

CD520P7W ◆
CD520B7W ▲

CD530MI7W ➤Q
CD530MIB7W ➤F
CD530MICB7W ➤B
CD530R7W ✚
CD530C7W ★

CD530P7W ◆
CD530B7W ▲

CD520R5W ✚
CD520C5W ★

CD520P5W ◆
CD520B5W ▲

CD530MI5W ➤Q
CD530MIB5W ➤F
CD530MICB5W ➤B
CD530R5W ✚
CD530C5W ★

CD530P5W ◆
CD530B5W ▲

125V

250V

3ØY
120/208V/AC

3ØY
277/480V/AC

3ØY
347/600V/AC

Locking Device LEGEND
HOW TO USE THESE CHARTS:
Core catalog number color indicates the type
of use a device is designed for:

A suffix combining a RED shape and alpha
letter indicate a device's body and type.

BLACK = Industrial Use

O-8

www.arrowhart.com

Device body:
✚
◆
★
▲
➤

Single Receptacle
Plug
Connector
Flanged Inlet
Mechanical Interlock

Device type:
B
E
F
Q
X

Circuit Breaker Option
Fusible
Fuse Option
Non-Fusible
Horizontal

2-Pole, 3-Wire Grounding

Poles, Wires

Pin & Sleeve Configurations

Rating

Receptacle, Connector &
Mechanical Interlocks

3-Pole, 4-Wire Grounding

100A Watertight
Pin & Sleeve
Receptacle, Connector &
Mechanical Interlocks

Plug & Inlet

Plug & Inlet

CD360R4W ✚
CD360C4W ★

CD360P4W ◆
CD360B4W ▲

CD3100MI4W ➤Q
CD3100R4W ✚
CD3100C4W ★

CD3100P4W ◆
CD3100B4W ▲

CD360P6W ◆
CD360B6W ▲

CD3100MI6W ➤Q
CD3100R6W ✚
CD3100C6W ★

CD3100P6W ◆
CD3100B6W ▲

250V

CD360MI6W ➤Q
CD360MIF6W ➤E
CD360R6W ✚
CD360C6W ★

CD360P7W ◆
CD360B7W ▲

CD3100MI7W ➤Q
CD3100R7W ✚
CD3100C7W ★

CD3100P7W ◆
CD3100B7W ▲

480V/AC

CD360MI7W ➤Q
CD360R7W ✚
CD360C7W ★

CD460MI12W ➤Q
CD460MIB12W ➤F
CD460MICB12W ➤B
CD460MIF12W ➤E
CD460R12W ✚
CD460C12W ★

CD460P12W ◆
CD460B12W ▲

CD4100MI12W ➤Q
CD4100R12W ✚
CD4100C12W ★

CD4100P12W ◆
CD4100B12W ▲

CD460MI9W ➤Q
CD460MIB9W ➤F
CD460MICB9W ➤B
CD460MIF9W ➤E
CD460R9W ✚
CD460C9W ★

CD460P9W ◆
CD460B9W ▲

CD4100MI9W ➤Q
CD4100R9W ✚
CD4100C9W ★

CD4100P9W ◆
CD4100B9W ▲

CD460MI7W ➤Q
CD460MIB7W ➤F
CD460MICB7W ➤B
CD460MIF7W ➤E
CD460R7W ✚
CD460C7W ★

CD460P7W ◆
CD460B7W ▲

CD4100MI7W ➤Q
CD4100R7W ✚
CD4100C7W ★

CD4100P7W ◆
CD4100B7W ▲

CD460MI5W ➤Q
CD460MIB5W ➤F
CD460MICB5W ➤B
CD460MIF5W ➤E
CD460R5W ✚
CD460C5W ★

CD460P5W ◆
CD460B5W ▲

CD4100MI5W ➤Q
CD4100R5W ✚
CD4100C5W ★

CD4100P5W ◆
CD4100B5W ▲

CD560MI9W ➤Q
CD560MIB9W ➤F
CD560MICB9W ➤B
CD560MIF9W ➤E
CD560R9W ✚
CD560C9W ★

CD560P9W ◆
CD560B9W ▲

CD5100MI9W ➤Q
CD5100R9W ✚
CD5100C9W ★

CD5100P9W ◆
CD5100B9W ▲

CD560MI7W ➤Q
CD560MIB7W ➤F
CD560MICB7W ➤B
CD560MIF7W ➤E
CD560R7W ✚
CD560C7W ★

CD560P7W ◆
CD560B7W ▲

CD5100MI7W ➤Q
CD5100R7W ✚
CD5100C7W ★

CD5100P7W ◆
CD5100B7W ▲

CD560MI5W ➤Q
CD560MIF5W ➤E
CD560R5W ✚
CD560C5W ★

CD560P5W ◆
CD560B5W ▲

CD5100MI5W ➤Q
CD5100R5W ✚
CD5100C5W ★

CD5100P5W ◆
CD5100B5W ▲

125V

125/250V/AC

3Ø 250V/AC

3Ø 480V/AC

3Ø 600V/AC

4-Pole, 5-Wire Grounding

60A Watertight
Pin & Sleeve

3ØY
120/208V/AC

3ØY
277/480V/AC

3ØY
347/600V/AC

Locking Device LEGEND
HOW TO USE THESE CHARTS:
Core catalog number color indicates the
type of use a device is designed for:

A suffix combining a RED shape and alpha
letter indicate a device's body and type.

BLACK = Industrial Use

www.arrowhart.com

Device body:
✚
◆
★
▲
➤

Single Receptacle
Plug
Connector
Flanged Inlet
Mechanical Interlock

Device type:
B
E
F
Q
X

Circuit Breaker Option
Fusible
Fuse Option
Non-Fusible
Horizontal

O-9

Horsepower Ratings
Horsepower Ratings for NEMA Configurations
(Plugs & Receptacles Only)
Straight Blade Configurations

Locking Configurations

NEMA

AC HP Rating

Rating

NEMA

AC HP Rating

Rating

1-15

0.5

15A-125V

L1-15

0.5

15A-125V

2-15

1.5*

15A-250V

L2-20

2*

20A-250V

2-20

2*

20A-250V

L5-15

0.5

15A-125V

2-30

2*

30A-250V

L5-20

1

20A-125V

5-15

0.5

15A-125V

L5-30

2

30A-125V

5-20

1

20A-125V

L6-15

1.5*

15A-250V

5-30

2

30A-125V

L6-20

2*

20A-250V

5-50

2

50A-125V

L6-30

2*

30A-250V

6-15

1.5*

15A-250V

L7-15

2

15A-277V/AC Only

6-20

2*

20A-250V

L7-20

2

20A-277V/AC Only

6-30

2*

30A-250V

L7-30

3

30A-277V/AC Only

6-50

3*

50A-250V

L8-20

3

20A-480V/AC Only

7-15

2

15A-277V/AC Only

L8-30

5

30A-480V/AC Only

7-20

2

20A-277V/AC Only

L9-20

NA

20A-600V/AC Only

7-30

3

30A-277V/AC Only

L9-30

NA

30A-600V/AC Only

7-50

5

50A-277V/AC Only

L10-20

2 L-L*/1 L-N

20A-125/250V

10-20

2L-L*/1 L-N

20A-125/250V

L10-30

2 L-L*/2 L-N

30A-125/250V

10-30

2 L-L*/2 L-N

30A-125/250V

L11-15

2

15A-3Ø 250V

10-50

3 L-L*/2 L-N

50A-125/250V

L11-20

3

20A-3Ø 250V

11-15

2

15A-3Ø 250V

L11-30

3

30A-3Ø 250V

11-20

3

20A-3Ø 250V

L12-20

5

20A-3Ø 480V

11-30

3

30A-3Ø 250V

L12-30

10

30A-3Ø 480V

11-50

7.5

50A-3Ø 250V

L13-30

NA

30A-3Ø 600V

14-15

1.5 L-L*/0.5 L-N

15A-125/250V

L14-20

2L-L*/1 L-N

20A-125/250V

14-20

2 L-L*/1 L-N

20A-125/250V

L14-30

2 L-L*/2 L-N

30A-125/250V

14-30

2 L-L*/2 L-N

30A-125/250V

L15-20

3

20A-3Ø 250V

14-50

3 L-L*/2 L-N

50A-125/250V

L15-30

3

30A-3Ø 250V

14-60

3 L-L*/2 L-N

60A-125/250V

L16-20

5

20A-3Ø 480V

15-15

2

15A-3Ø 250V

L16-30

10

30A-3Ø 480V

15-20

3

20A-3Ø 250V

L17-30

NA

30A-3Ø 600V

15-30

3

30A-3Ø 250V

L18-20

2

20A-3ØY 120/208V

15-50

7.5

50A-3Ø 250V

L18-30

3

30A-3ØY 120/208V

15-60

10

60A-3Ø 250V

L19-20

5

20A-3ØY 277/480V

18-15

2

15A-3ØY 120/208V

L19-30

10

30A-3ØY 277/480

18-20

2

20A-3ØY 120/208V

L20-20

NA

20A-3ØY 347/600V

18-30

3

30A-3ØY 120/208V

L20-30

NA

30A-3ØY 347/600V

18-50

7.5

50A-3ØY 120/208V

L21-20

2

20A-3ØY 120/208V

18-60

7.5

60A-3ØY 120/208V

L21-30

3

30A-3ØY 120/208V

L-L denotes phase-to-phase HP rating

L22-20

5

20A-3ØY 277/480V

L-N denotes phase-to-neutral HP rating

L22-30

10

30A-3ØY 277/480V

*Suitable for 208V motor applications at HP rating

L23-20

NA

20A-3ØY 347/600V

L23-30

NA

30A-3ØY 347/600V

L-L denotes phase-to-phase HP rating
L-N denotes phase-to-neutral HP rating
*Suitable for 208V motor applications at HP rating

O-10

www.arrowhart.com

Common Industry Information
Organization Abbreviations Glossary
Common abbreviations for organizations often referred to in the electrical industry, and also noted throughout
the Arrow Hart catalog:
ANSI

NFPA

American National Standards Institute, Inc.

National Fire Protection Association

ANSI is a private, non-profit organization that administers
and coordinates the U.S. voluntary standardization and
conformity assessment system. The Institute’s mission is to
enhance both the global competitiveness of U.S. business
and the U.S. quality of life by promoting and facilitating
voluntary consensus standards and conformity assessment
systems, and safeguarding their integrity. www.ansi.org

The mission of the international non-profit NFPA is to
reduce the worldwide burden of fire and other hazards on
the quality of life by providing and advocating scientifically
based consensus codes and standards, research, training
and education. The NFPA authors the NEC® and NPPA 70E
electrical safety in the workplace. www.nfpa.org
NOM

CSA

Normas Officials de Mexico
(Official Mexican Standards)

Canadian Standards Association
The Canadian Standards Association is a not-for-profit,
membership-based association that conducts product
safety testing, and issues certifications. www.csa.org
GSA
General Services Administration Federal Supply Service
GSA’s Federal Supply Service provides federal customers
with a specific list of manufacturer’s products that have
been approved to meet stated requirements. The most
frequently cited Federal Specifications regarding electrical
wiring devices are those for Electrical Power Connector,
Plug, Receptacle and Cable Outlet (Fed. Spec. W-C 596)
and for Toggle and Lock, Flush Mounted Switches (Fed.
Spec. W-S 896). www.gsa.gov
NEC®
National Electrical Code®
Published by the NFPA (see listing) as NFPA 70,
the National Electrical Code

The Official Mexican Standards (referred to as Normas or
NOMs) augment the Mexican Hazardous Materials Land
Transportation Regulation and provide information relative
to importing and exporting hazardous materials from and
to Mexico.
OSHA
Occupational Health and Safety Administration,
U.S. Department of Labor
OSHA’s mission is to assure safe and healthful working
conditions for working men and women (having been
authorized to enforce standards first created under the
Occupational Health and Safety Act of 1970 and since
evolved), by assisting and encouraging the States in their
efforts to assure safe and healthful working conditions.
www.osha.gov
UL
Underwriters Laboratories

This publication, renewed every 3 years under the auspices
of ANSI, provides for the adequate protection of life and
property from dangers associated with the use of
electricity. It is now adopted and enforced in all 50 states in
the United States, and is also the basis for electrical codes
in several other countries. www.nfpa.org

Underwriters Laboratories Inc. (UL) is an independent,
not-for-profit product safety testing and certification
organization. www.ul.com

NEMA

NSF International helps protect people by certifying
products and writing standards for consumer goods. As
an independent, not-for-profit organization, NSF works
toward allowing everyone to live safer. www.nsf.org

National Electrical Manufacturers Association
Comprised of electrical manufacturers, NEMA provides a
forum for the standardization and testing of electrical
equipment, enabling consumers to select from a range of
safe, effective, and compatible electrical products. NEMAstandards of testing is frequently required by both
government and third-party endorsees such as UL and
CSA prior to their approval. www.nema.org

NSF
NSF International

www.arrowhart.com

O-11

Common Industry Information
Common Industry Organization Acronyms
Standards Development Organizations
ANSI
ASME
CANENA

Codes and Standards

IEC

American National Standards Institute
American Society of Mechanical Engineers
Consejo de Armonizacion de Normas Electrotecnicas de Norte
America (Council for Harmonization of Electrotechnical
Standardization of North America)
International Electrotechnical Commission

IEEE

Institute of Electrical and Electronics Engineers

ISA

Instrument Society of America

ISO

International Standards Organization

NFPA

National Fire Protection Agency

NSF

NSF International

SAE

Society of Automotive Engineers

SME

Society of Manufacturing Engineers

CEC

Canadian Electrical Code

CEE

European Electrotechnical Committee

NEC

National Electrical Code®

NMX

Normas Mexicanas

NOM

Normas Oficiales de Mexicanas (Official Mexican Standard)

Industry Associations
ABYC

American Boat and Yacht Council

BICSI

Building Industry Consulting Services International

BOMA

Building Owners Management Association

CANAME

Camara Nacional de Manufacturas Electricas (Mexico)

CEMRA

Canadian Electrical Manufacturers Representatives
Association

National Association of Normalization and Certification of the
Electrical Sector (Mexico)

ECOC

Electrical Contractors of Canada

EFI

Electro-Federation Incorporated

BSI

British Standards Institute

EIA

Electronics Industry Association

CI

European Compliance (This is not a certification agency, but
CE is the European Compliance Mark)

EPRI

Electric Power Research Institute

IAEI

International Association of Electrical Inspectors

IBI

Intelligent Building Institute

IECA

Independent Electrical Contractors Association

IFMA

International Facilities Management Association

NAED

National Association of Electrical Distributors

NAW

National Association of Wholesalers

NECA

National Electrical Contractors Association

NEMA

National Electrical Manufacturers Association

NEMRA

National Electrical Manufacturers Representative Association

NMDA

National Marine Distributor Association

Occupational Safety and Health Administration

NMRA

National Marine Representative Association

TUV Rheinland of N.A., Inc.

SEMI

Semi-Conductor Equipment and Material International

Verband Deutscher Elektrotechniker (Germany)

TIA

Telecommunications Industry Association

Underwriters Laboratories

USGBC

US Green Building Council

Certification Agencies
ANCE

CSA

Canadian Standards Association

cUL

Certified to CSA Standards by Underwriters Laboratories

cULus

Meets Canadian & US UL requirements

DESC

Defense Electronic Supply Center

ETL

Electrical Testing Laboratories

FCC
FM
IAPA

Federal Communications Commission
Factory Mutual
Independent Accident and Protection Association (Canada)

LEED

Leadership in Energy and Environmental Design

NRTL

National Recognized Testing Laboratories

OSHA
TUV
VDE
UL

Common UL & CSA Standards For Wiring Devices
UL Standards Pertaining to Arrow Hart Products

UL Standards Pertaining to Arrow Hart Products

O-12

UL 20

General-use switches

UL 1786

Night-lights

UL 50

Enclosures for electrical equipment

UL 1863

Communications circuit accessories

UL 94

Flammability testing for materials, plastic

UL 1917

Solid state fan speed control

UL 486E

Equipment and wiring terminals

FSWC596

Fed. Spec. receptacles

UL 496

Lampholders

FSWS896

Fed. Spec. switches

UL 498

Plugs, connectors, receptacles, inlets, outlets

UL 498A

Taps and adapters

UL 508

Industrial equipment (including motor control switches)

UL 514A

Metallic boxes/covers/wallplates

UL 514D

Nonmetallic boxes/covers/wallplates

UL 817

Cord sets

UL 943

GFCIs

UL 1054

Special use switches

UL 1363

Temporary power taps

UL 1436

Outlet circuit testers

UL 1449

Surge suppression devices

UL 1472

Dimmers

UL 1567
UL 1699

Switches and receptacles used with AL wire
Arc fault circuit interrupters

CSA Standards Pertaining to Arrow Hart Products
C22.2 No. 0.17

Polymeric materials

C22.2 No. 12

Night Lights

C22.2 No. 42

General-use receptacles, attachment plugs

C22.2 No. 55

Special-use switches

C22.2 No. 111

General-use switches

C22.2 No. 144

GFCI

C22.2 No. 182.1

Industrial-type, special-use attachment plugs,
receptacles and connectors. Pin and sleeve devices.

C22.2 No. 182.2

Industrial locking type

www.arrowhart.com

Common Industry Information
General Purpose Wiring Device Definitions from NEMA Standard WD-1
NEMA Standards Pertaining to Arrow Hart Products (in accordance with NEMA Standard WD-1)
WD 1-1.01
Cord Connector
A portable receptacle with means for attachment to a flexible
cord, the cord connector is not intended for permanent
mounting.
NEMA Standard 7-13-1967

WD 1-1.10
Receptacle
This device features female contacts, and is installed primarily
at an outlet or on equipment meant to establish electrical
connection with an inserted plug.
NEMA Standard 7-1-1967

WD 1-1.02
Grounded Conductor (System Ground)
This is a usually current-carrying circuit conductor that’s
purposely connected to earth ground, and is identified as the
white conductor.
NEMA Standard 7-13-1967

WD 1-1.11
Slant Symbol ( / )
As it applies to wiring device ratings, the “slant” line( / ) indicates
that there’s more than one voltage potential present between
different terminals of a wiring device.
NEMA Standard 7-1-1967

WD 1-1.03

WD 1-1.12
Switch
There are several different types of switches available for
making, breaking, or changing electrical circuit connections,
including:
A. Single-Pole Switch (Single-Pole, Single-Throw), which
makes or breaks the connection of a single conductor.
B. Double-Pole Switch (Double-Pole, Single-Throw), which
makes or breaks the connection of two conductors on a
single branch circuit.
C. Three-Way Switch (Single-Pole, Double-Throw), which
changes the connection of a single conductor and is
most often utilized in tandem to better control one piece
of equipment from two locations.
D. Four-Way Switch (Double-Pole, Double-Throw
Reversing) is a double-pole switch used with two threeway switches to control a single piece of equipment from
more than two locations.
NEMA Standard 7-13-1967

Grounding Conductor
(Equipment Ground)
Unlike the System Ground version, this conductor connects
non-current-carrying metallic equipment parts to earth ground,
providing a specific path for fault current to ground. It can be
bare or covered, in which case it is identified as the green
conductor, or green with yellow stripes.
NEMA Standard 7-13-1967
WD 1-1.04
Lampholder
Lampholders mechanically support an electric lamp, and
electrically connect it to a circuit.
NEMA Standard 7-13-1967
WD 1-1.05
Male Base (Inlet)
Designed for flush or surface mounting on an appliance or other
equipment, male-based plugs serve to connect utilization
equipment to a connector.
NEMA Standard 7-13-1967

WD 1-1.13
Terminal (on a Wiring Device)
A terminal is a fixed location on a wiring device where a
conductor is designated for connection.
NEMA Standard 7-13-1967

WD 1-1.06
Outlet
An outlet is a point on the wiring system at which current is
taken to supply utilization equipment.
NEMA Standard 7-13-1967

WD 1-1.14
Wire (Plugs and Receptacles)
As it applies in designating plugs and receptacles, the term
“wire” stands for the number of either regularly current-carrying
or equipment grounding connected conductors.
NEMA Standard 7-13-1967

WD 1-1.07
Plug
The male blades of our plugs serve to connect the conductors
of the attached, flexible cord with those of the female
receptacle.
NEMA Standard 7-1-1967
WD 1-1.08
Polarization (Plugs and Receptacles)
Polarization assures the correct positioning for proper mating of
plugs and receptacles of the same rating.
NEMA Standard 7-1-1967
WD 1-1.09
Pole
When used to designate plugs and receptacles, “pole” refers to
a terminal that is connected to a regularly current-carrying
circuit conductor. In switches, the number of poles indicates
how many conductors are being controlled.
NEMA Standard 7-1-1967

For answers to technical questions, or for more information
on UL, CSA, and NEMA standards pertaining to Cooper Wiring
Devices’ products, call our toll free number:
1-866-853-4293. Or, visit our website at
www.cooperwiringdevices.com.

www.arrowhart.com

O-13

Common Industry Information
Selected Articles, National Electric Code (NEC®) Requirements for Wiring
Devices From NFPA 70™, NEC® 2008 Edition
Article 210 — Branch Circuits
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel
210.21 Branch Circuit Ratings, Outlet Devices
210.24 Branch Circuit Requirements - Summary
210.50 Required Outlets, General
210.60 Required Outlets, Guest Rooms, Guest Suites, Dormitories
and Similar Occupancies
210.62 Required Outlets, Show Windows
210.70 Lighting Outlets Required
Article 404 — Switches
404.2 Installation, Switch Connections
404.3 Installation, Enclosure
404.4 Installation, Damp or Wet Locations
404.9 Installation, Provisions for General-Use Snap Switches
404.14 Rating and Use of Snap Switches
404.15 Construction Specifications, Marking
Article 406 — Receptacles, Cord Connectors and
Attachment Plugs (Caps)
406.2 Receptacle Rating and Type
406.3 General Installation Requirements
406.4 Receptacle Mounting
406.5 Receptacle Faceplates (Cover Plates)
406.6 Attachment Plugs, Cord Connectors and Flanged
Surface Devices
406.7 Noninterchangeability
406.8 Receptacles in Damp or Wet Locations
406.9 Grounding-Type Receptacles, Adapters, Cord
Connectors and Attachment Plugs
406.11 Tamper-Resistant Receptacles in Dwelling Units
Article 430 — Motors, Motor Circuits and Controllers
430.8 Marking on Controllers
430.81 Motor Controllers, General
430.82 Motor Controllers, Controller Design
430.83 Motor Controllers, Ratings
430.90 Combination Fuseholder and Switch as Controller
430.102 Disconnecting Means, Location
430.109 Disconnecting Means, Type

Article 517 — Health Care Facilities
517.2 Definitions
517.10 Wiring and Protection, Applicability
517.13 Grounding of Receptacles and Fixed Electrical Equipment
in Patient Care Areas
517.14 Panelboard Bonding
517.16 Receptacles with Insulated Grounding Terminals
517.17 Ground-Fault Protection
517.18 Wiring and Protection, General Care Areas
517.19 Wiring and Protection, Critical Care Areas
517.20 Wiring and Protection, Wet Procedure Locations
517.21 Ground-Fault-Circuit-Interrupter Protection for Personnel
517.30 Essential Electrical Systems for Hospitals
517.31 Emergency System
517.35 Sources of Power
517.40 Essential Electrical Systems for Nursing Homes and
Limited Care Facilities
517.41 Essential Electrical Systems (Nursing Homes, etc.)
517.45 Essential Electrical Systems for Other Health Care Facilities
517.61 Inhalation Anesthetizing Locations, Wiring and Equipment
517.62 Inhalation Anesthetizing Locations, Grounding
517.63 Grounded Power Systems in Anesthetizing Locations
517.64 Inhalation Anesthetizing Locations, Low-Voltage
Equipment and Instruments
517.71 X-Ray Installations Connection to Supply Circuit
517.72 X-Ray Installations Disconnecting Means
517.160 Isolated Power Systems
Article 555 — Marinas and Boatyards
555.1 Scope
555.13 Wiring Methods and Installations
555.19 Receptacles (including GFCI)
Article 590 — Temporary Installations
590.4 General (including Receptacles and GFCI)
Article 604 — Manufactured Wiring Systems
604.2 Definition
604.6 Construction (including Receptacles and Connectors)
Article 630 — Electric Welders
630.13 Arc Welders, Disconnecting Means
630.33 Resistance Welders, Disconnecting Means
Article 647 — Sensitive Electronic Equipment
647.7 Receptacles (including Isolated Ground Receptacles)
Article 660 — X-Ray Equipment
660.4 Connection to Supply Circuit
660.5 Disconnecting Means
Article 700 — Emergency Systems
700.26 Overcurrent Protection, Ground-Fault Protection of
Equipment

O-14

www.arrowhart.com

Wire and Cable Information
Wire & Cable Type Abbreviations
KEY:
S = Service
J = Junior
T = Thermoplastic/Vinyl

W = Weather Approved
P = Parallel

■ SJT: Hard usage thermoplastic rubber-insulated conductors
and overall thermoplastic jacket. 300V, 60ºC to 105ºC.

■ SPT-3: Same as SPT-2, but heavier construction (18-10 gauge).

■ SJTW: Hard usage thermoplastic or rubber-insulated
conductors and overall thermoplastic jacket. 300V, 60ºC to
105ºC. Weather resistant for outdoor use.

■ SRDT: Portable range or dryer cable, 3-conductor parallel type or 4
insulated conductors, jacketed. All thermoplastic construction. 300V,
maximum temperature of 60ºC.

■ SPT-1: All thermoplastic construction, parallel jacketed. 300V,
60ºC to 105ºC, 2 or 3-conductor (18 gauge).

■ HPN: Two-conductor, neoprene-insulated heater cord. Parallel
construction. For use in damp locations. 300V, 90ºC.

■ SPT-2: Same as SPT-1, but heavier construction (18-16 gauge).

Diameter Ranges of Jacketed Cord in Accordance with
Standard UL62
Acceptable Range for Overall Diameter of Jacketed Cord
Type of Cord

Avg. Size

SV, SVO, SVT,
SVTO

18

SJ, SJO, SJT,
SJTO

S, SO, ST, STO

2-Conductor

3-Conductor

4-Conductor

5-Conductor

0.22"-0.26"
(5.6mm-6.6mm)

0.23"-0.27"
(5.8mm-6.9mm)

—

—

18

0.28"-0.32"
(7.1mm-8.1mm)

0.30"-0.34"
(7.6mm-8.6mm)

0.33"-0.37"
(8.4mm-9.4mm)

—

16

0.31"-0.34"
(7.9mm-8.6mm)

0.33"-0.36"
(8.4mm-9.1mm)

0.35"-0.40"
(8.9mm-10.2mm)

—

14

0.34"-0.38"
(8.6mm-9.7mm)

0.36"-0.40"
(9.1mm-10.2mm)

0.39"-0.44"
(9.9mm-11.2mm)

—

12

0.41"-0.46"
(10.4mm-11.7mm)

0.43"-0.48"
(10.9mm-12.2mm)

0.47"-0.52"
(11.9mm-13.2mm)

—

10

0.54"-0.61"
(13.7mm-15.5mm)

0.57"-0.64"
(14.5mm-16.3mm)

0.63"-0.70"
(16.0mm-17.8mm)

—

18

0.34"-0.39"
(8.6mm-9.9mm)

0.36"-0.40"
(9.1mm-10.2mm)

0.39"-0.43"
(9.9mm-10.9mm)

0.46"-0.51"
(11.7mm-13.0mm)

16

0.37"-0.41"
(9.4mm-10.4mm)

0.39"-0.43"
(9.9mm-10.9mm)

0.41"-0.46"
(10.4mm-11.7mm)

0.49"-0.55"
(12.4mm-14.0mm)

14

0.50"-0.55"
(12.7mm-14.0mm)

0.52"-0.58"
(13.2mm-14.7mm)

0.56"-0.62"
14.2mm-15.7mm)

0.63"-0.71"
(16.0mm-18.0mm)

12

0.57"-0.63"
(14.5mm-16.0mm)

0.59"-0.66"
(15.0mm-16.8mm)

0.64"-0.71"
(16.3mm-18.0mm)

0.70"-0.77"
(17.8mm-19.6mm)

10

0.62"-0.69"
(15.7mm-17.5mm)

0.65"-0.72"
(16.5mm-18.3mm)

0.70"-0.78"
(17.8mm-19.8mm)

0.76"-0.84"
(19.3mm-21.3mm)

8

0.78"-0.88"
(19.8mm-22.4mm)

0.83"-0.93"
(21.1mm-23.6mm)

0.93"-1.05"
23.6mm-26.7mm)

1.00"-1.15"
(25.4mm-29.2mm)

6

0.92"-1.05"
(23.4mm-26.7mm)

0.97"-1.10"
(24.6mm-27.9mm)

1.05"-1.20"
(26.7mm-30.5mm)

1.18"-1.33"
(30.0mm-33.8mm)

4

1.06"-1.21"
(26.9mm-30.7mm)

1.13"-1.28"
(28.7mm-32.5mm)

1.25"-1.45"
(31.8mm-3.8mm)

—

2

1.21"-1.40"
(30.7mm-35.6mm)

1.30"-1.50"
33.0mm-38.1mm)

1.45"-1.65"
(36.8mm-41.9mm)

—

www.arrowhart.com

O-15

Wiring Diagrams
Wiring Diagrams by NEMA Configurations

2-Pole, 2-Wire Non-Grounding: 125V

2-Pole, 2-Wire Non-Grounding: 250V

2-Pole, 3-Wire Grounding: 125V

2-Pole, 3-Wire Grounding: 250V

2-Pole, 3-Wire Grounding: 277V AC

2-Pole, 3-Wire Grounding: 480V AC

3-Pole, 3-Wire Non-Grounding: 125/250V

3-Pole, 3-Wire Non-Grounding: 3Ø 250V

3-Pole, 4-Wire Grounding: 125/250V

3-Pole, 4-Wire Grounding: 3Ø 250V

O-16

www.arrowhart.com

Wiring Diagrams
Wiring Diagrams by NEMA Configurations

3-Pole, 4-Wire Grounding: 3Ø 480V

3-Pole, 4-Wire Grounding: 3Ø 600V

4-Pole, 4-Wire Non-Grounding: 3Ø 120/208V

4-Pole, 4-Wire Non-Grounding: 3Ø 277/480V

4-Pole, 4-Wire Non-Grounding: 3Ø 347/600V

4-Pole, 5-Wire Grounding: 3Ø 120/208V

4-Pole, 5-Wire Grounding: 3Ø 277/480V

4-Pole, 5-Wire Grounding: 3Ø 347/600V

www.arrowhart.com

O-17

Wiring Diagrams
Receptacles

15A-125V

GFCI: Feed-Through Installation with Protection
Provided Downstream

GFCI: Feed-Through Installation with Non-Protected
Receptacles Downstream

GFCI: Feed-Through Installation with Both Protected and
Non-Protected Receptacles Downstream

Combination Devices

2 Single-Pole
Switches

O-18

Single-Pole Switch and
2-Pole, 3-Wire 20A U
Grounding Receptacle

Single-Pole
Switch and
Neon Pilot Light

www.arrowhart.com

Single-Pole Switch
and 2-Pole, 3-Wire U
Grounding Receptacle

Wiring Diagrams
Switches
AC Switches & Standard Switches

Pilot Light Switch & Lighted Switch, Single and Double Pole

Pilot Light Switch & Lighted Switch, 3-Way

Maintained & Momentary Contact, Single-Pole

Maintained & Momentary Contact, Double-Pole

Maintained
Contact
3-Position,
2-Circuit
Center “Off”

Momentary
Contact Either
Direction
3-Position,
Center “Off”

Maintained
Contact Either
Direction
2-Position,
No Center “Off”

Manual Contactors & Disconnect Switches
On–Off–On
2-Phase Circuit

On–Off–On
Single Phase Circuit

L

L

T

T

1 1

1 2

L1

L2
T

L1

N

T

2 1

2 2

L

L

AH4361, AH4371 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch

AH4361, AH4371 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch

www.arrowhart.com

O-19

Wiring Diagrams
Manual Contacts & Disconnect Switches, by Motor Variations

Repulsion Induction

Capacitor Two Windings

L1

T2

T4

L1

L2

HIGH
OFF

T1

T3

T2

T4

L1

L2

T1

T3

T2

T4

L1

L2

HIGH
LOW

OFF
T1

L1

T3

T2

L2 & T3

&
T2

&
T4

L1

T5

HIGH

L1

L2 to T2

&
T1

&
T3

T2

L2

L1

FORWARD
REVERSE

T8

REVERSE

T1

T3

&
T2

&
T4

T1

T3

&
T4

&
T2

L2

LOW

T2

L2

OFF
T3

T1

T5

T1

L1

Diagram 6

L1

OFF

REVERSE
S2

S1

A1

REVERSE

A2

A1

Diagram 9

Diagram 8

A2

L2

T1

T2

T3

OFF
REVERSE
S1

S2

A1

F1

HIGH
Ø A

OFF

Ø B

LOW
T11

T12

T13

T14

FORWARD

L3
L1
L2
L4

Ø A

OFF

Ø B

REVERSE
T1

T2

T3

F2

Diagram 11

O-20

A2

2-Phase Induction

T4

FORWARD

L3
L1
L2
L4

F2

Diagram 10

2-Phase Separate Winding

L1

T4

FORWARD

OFF

T3

Compound DC

REVERSE

T8

F1

Diagram 7

FORWARD

L2

REVERSE
T1

T4

L1

FORWARD

OFF

T13

T2

Shunt DC

FORWARD

L1
L2
L3

L1

Series DC

3-Phase Induction

OFF

L2

T4

T5

T3

L1
L2
L3
T12

FORWARD

T3

T1

HIGH

T11

L2

Diagram 5

3-Phase Separate Winding
T1

T4

L1

Split Phase

Diagram 5 & 6
Internal Connections

OFF

Diagram 4

A1

Diagram 3

T2

T1

REVERSE

S2

A2

L2

L2

LOW
T4

T1
T2

L1

FORWARD

T3

S1

T5

Capacitor

Diagram 4 Internal Connections

L2

T1

REVERSE

Diagram 2

Diagram 1

T4

L1

OFF

T4

T8

L2

T2

L1

OFF

LOW

L2

Capacitor Consequent Pole

FORWARD

L1

T1

L2

Series

Diagram 12

www.arrowhart.com

Diagram 13

T4

Dimensional Data
Switch Dimensional Data

AH6808UDAC, AH6808UCO

AH6810U, AH7810UD
Tap
#6/32"
(4.7mm)

2.38"
(60.4mm)

ON

3.28"
(83.3mm)
4.06"
(103.1mm)

1.38"
(35.0mm)

3.28"
(83.3mm)
2.38"
(60.4mm)

2.22"
(56.4mm)

1.31"
(33.3mm)

1.04"
(26.4mm)

AHMC240L, AHMC340L, AHMC260L,
AHMC360L
1.66"
(42.2mm)
.06"
(1.5mm)

1.75"
(44.5mm)

1.69"
(42.9mm)

AHMC240C, AHMC340C
1.66"
(42.2mm)
.06"
(1.5mm)

1.74"
(44.2mm)
(2).22 Dia.
(5.6mm)
Mtg. Holes

2.23"
(56.6mm)
(2).22" Dia.
(5.6mm)
Mtg. Holes

OFF

2.31"
(58.7mm)

3.81"
(96.8mm)
2.31"
(58.7mm)

OFF

3.75"
(95.3mm)

ON

3.28"
2.38" (83.3mm)
(60.5mm)

(2)#6/32"Tap
(4.8mm)

2.31"
(58.7mm)

OFF

ON

Clamps Accept
#8-#14 Wire

Box Lugs Accept
#4-#14 Wire

3.75"
(95.3mm)

3.28"
(83.3mm)
2.38"
(60.5mm)

(2)#6/32 Tap

AH4361, AH4371
(2) .20"
(5.1mm)
Holes
3.28"
(83.3mm)

D

3.78"
(96.0mm)

A

C

B

A

B

C

D

AH4361

1.59"
(40.4mm)

1.66"
(42.2mm)

0.66"
(16.8mm)

2.50"
(63.5mm)

AH4371

1.81"
(46.0mm)

1.98"
(50.3mm)

1.22"
(31.0mm)

2.88"
(73.2mm)

www.arrowhart.com

O-21

Dimensional Data
Enclosure Dimensional Data

AHMC360L-1, AHMC260L-1, AH781OGD, AHMC340C-1,
AHMC340L-1, AH6808GDAC, AH6810G, AHMC240C-1,
AHMC240L-1, AH27940G, AHN1GD

AH6810E, AH7810ED
2.63"
(66.8mm)

.75" Hub
(19.1mm)

1.38"(35.1mm)

1/2" (12.70mm) Conduit KO Centered on Back

6.75"
(171.5mm)

4.25"
(108.0mm)
Ground Screw

OFF

5.88"
(149.4mm)

3.00"
(76.2mm)

MANUAL MOTOR STARTER

3.50"
(88.9mm)

.34"
(8.6mm)

2.92"
(74.2mm)

4.75"
(120.7mm)

AH6808WDAC

2.50"
(63.5mm)
2.63"
(66.8mm)
Shroud Accepts up to
5/16" (7.9mm) Dia. Lock Shank

AH7810GDB, AHN1GD2

AHN1GD2D

Dim A=2.63" (66.80mm)

Dim A=3.87" (98.30mm)

.75" Hub
(19.1mm)

5.81"
(147.6mm)

(3).25" (6.4mm) Dia. Hole

Knockouts for .75 - 1.00 (19.05-25.4mm)
Conduit (5 Plc.'s)
(3).25 (6.4mm) Mtg. Hole
2.00" (50.8mm)

ON
OFF

4.42"
(112.3mm)

OFF

1.50" (38.1mm)

4.25"
(108.0mm)

1.37"
(34.8mm)

2.75"
(69.9mm)

'A'

4.67"
(118.6mm)

3.43"
(87.1mm)

AHN3WD, AH6808WDAC, AH6810W,
AHMC240C-3, AHMC240L-2, AHMC260L-3,
AHMC340C-3, AHMC340L-2, AHMC360L-2

#14-#4
Ground Lug

Shroud Accepts up to
5/16" Dia. (7.9mm) Lock Shank

AH6808FDAC (plate only, no toggle guard)
AH7810FD

2.75"
(69.9mm)

6.00"
(152.4mm)

ON

3.00"
(76.2mm)

F

4.50"
(114.3mm)

MANUAL MOTOR CONTROLLER

4.50"
(114.3mm)

4.00"
(101.60mm)

1.50"
2.50"
(38.10mm)
(63.50
mm)
(2).25" (6.35mm) Dia.
Embossed Mtg. Hole

2.31"
(58.7mm)

OFF

C

MANUAL MOTOR CONTROLLER

.19"
(4.8mm)
1.68"
(42.7mm)

O-22

www.arrowhart.com

Dimensional Data
Snap-In Receptacle Panel Cutouts
Panel Cutout
67

Panel Cutout
49

0.968"
(24.6mm)
1.07"
(27.2mm)
0.968"
(24.6mm)
Panel Thickness 0.032'' ñ 0.070''
(0.81mm ñ 1.78mm)

0.77"
(19.6mm)
Panel Thickness 0.032'' – 0.070''
(0.81mm – 1.78mm)

Attachon Lampholder Cutouts
Panel Cutout
732-3

1.53"
(38.86mm)
1.41"
(35.8mm)

Panel Cutout
734
" )
38 m
1. .8m a.
4
(3 Di

Panel Cutout
4734-2
0.188"
(4.8mm)
Diam.

1.8"
(46.0mm)

0.188"
(4.8mm)

1.38"
(34.8mm)

2.13"
(54.1mm)

0.34"
(8.6mm)
Panel Cutout

Panel Cutout
731-2, 731-3
" )
90 m
0. .8m a.
2
(2 Di

0.063"
(1.6mm)
1.03"
(26.0mm)
0.425"
(10.8mm)

0.82"
(20.8mm)

0.125"
(3.2mm)

www.arrowhart.com

O-23

Switch Applications
Test Requirements
The maximum permitted load for which a switch is suitable depends on the switch rating and the nature of the load. Proper
selection of switches is determined by test standards and requirements of the National Electrical Code®, Articles 380, 430,
and 600.
General Use AC switches are suitable for use at full rated current and voltage on loads of fluorescent and incandescent
lighting and for other inductive or resistance loads. Our switches are rated for motor loads at 80% of their rated current.
Special Use AC switches may be used at full rating on resistance or inductive loads, including fluorescent. For
incandescent (tungsten) lighting loads, they must carry an “L” rating. For motor loads they require an “HP” (horsepower)
rating.
To ensure safety and reliability, Arrow Hart switches are tested, rated and marked according to various standards. The
following charts indicate both the required performance tests specified by industry standards for switches with standard
ratings, and the loads they may control.
Test Requirements - Switches* General Use - AC Only
Overload
Standard*

Rating

Amps
15A,
120V/AC

15A
120/277
277V/AC
20A,
120/277
277V/AC
20A,
120/277
277V/AC

UL 20 &
NEMA G.D.
WS 896 &
NEMA H.D.
UL 20 &
NEMA G.D.
WS 896 &
NEMA H.D.
UL 20 &
NEMA G.D.
WS 896 &
NEMA H.D.
UL 20 &
NEMA G.D.
WS 896 &
NEMA H.D.

Volts

Endurance

Power
Factor

Cycles

Volts
(Max)

Amps

Resistance
Cycles 1.0
pf. †

Inductive
Cycles
.75 to .8 pf. †

Tungsten
Cycles 1,0
pf. †

72

120 AC

.4 to .5

100

15

120 AC

10,000

10,000

10,000

72

120 AC

.4 to .5

100

15

120 AC

10,000

50,000

50,000

72

277 AC

.4 to .5

100

15

277 AC

10,000

10,000

10,000

72

277 AC

.4 to .5

100

15

277 AC

10,000

50,000

50,000

96

277 AC

.4 to .5

100

20

277 AC

10,000

10,000

10,000

96

277 AC

.4 to .5

100

20

277 AC

10,000

50,000

50,000

144

277 AC

.4 to .5

100

30

277 AC

10,000

10,000

10,000

144

277 AC

.4 to .5

100

30

277 AC

10,000

50,000

50,000

Test Requirements - Switches Special Use - AC Only
Overload
Rating

Standard*

8A, 120V/AC

UL 1054

15A, 120V/AC
10A, 240V/AC
3/4 HP,
120-240V/AC

UL 1054

15A,
125-250V/AC
3/4 HP,
120-240V/AC
20A, 125V/AC “L”
20A, 250V/AC
1 HP,
120-240V/AC

UL 1054

UL 1054

15

22.5

30

240
AC

250
AC

240
AC

*NEMA G.D. is NEMA Standard WD-1 General Duty.
NEMA H.D. is NEMA Standard WD-1 Heavy Duty.
WS896 is current Federal Specification.

O-24

Endurance

Horse Power

“L” Tungsten

Power
Power
Power
Amps Volts
Cycles Amps Volts
Cycles Amps Volts
Cycles Amps Volts Cycles
Factor
Factor
Factor
120 .4-.5
120 .75-.8 6000
12
50
8
–
–
–
–
–
–
–
AC
AC

.4-.5

.4-.5

.4-.5

50

50

50

10

15

20

240
AC

250
AC

250
AC

.75-.8

.75-.8

.75-.8

82.8

120
AC

41.4

240
AC

.4-.5

50

82.8

120
AC

.4-.5

50

41.4

240
AC

.4-.5

50

96

120
AC

.4-.5

50

48

240
AC

.4-.5

50

6000

6000

6000
.4-.5

–

–

–

–

–

20

125
AC

6000

50

All switches are subjected to Resistive Endurance, Inductive
Endurance, Tungsten Endurance and then verified that they meet
less than a 86ºF (30ºC) temperature rise at rated current and
voltage, followed by a dielectric test at 1500 VAC for 1 minute.

www.arrowhart.com

–

† Power Factor

Switch Applications
Maximum Loads
Maximum Loads - Switches - General Use - AC Only
Incandescent

Inductive (Fluorescent)

Resistance

Motors

Switch Rating
Volts

Amps

Volts

Amps

Volts

Amps

Volts

HP

Amps

15A, 120V/AC

120 AC

15

120 AC

15

120 AC

15

120 AC

1/2

12

20A, 120V/AC

120 AC

20

120 AC

20

120 AC

20

120 AC

1

16

15A, 120/277V/AC

120 AC

15

277 AC

15

277 AC

15

20A, 120/277V/AC

120 AC

20

277 AC

20

277 AC

20

30A, 120/277V/AC

120 AC

30

277 AC

30

277 AC

30

1/2
1
1
2
2
2

12
12
16
16
24
24

120
240
120
240
120
240

AC
AC
AC
AC
AC
AC

Maximum Loads - Switches - Special Use - AC Only
Incandescent

Inductive (Fluorescent)

Resistance

Motors

Switch Rating
Volts
8A, 120V/AC
15A, 120V/AC
10A, 240V/AC
3/4HP, 120/240V/AC
15A, 120-240V/AC
3/4HP, 120/240V/AC

Amps

Volts

Amps

Volts

Amps

V/AC

120 AC

8

120 AC

8

120 AC

15

120 AC

15

Not Suitable

250 AC

10

240 AC

10

240V/AC

3/4

12

Not Suitable

250 AC

15

250 AC

15

240V/AC

3/4

12

250 AC

20

250 AC

20

240V/AC

1

12

Not Suitable

HP

Amps

Not Suitable

20A,120V/AC “L”
20A, 250V/AC

125 AC

20

1HP, 120/240V/AC

www.arrowhart.com

O-25

Switch Applications or Materials
Chemical Resistant Properties of Common Materials in Wiring Devices

Acids

Alcohol

Caustic
Bases

Gasoline

Grease

Kerosene

Oil

Solvents

Water

Nylon
(Thermoplastic)

3

1

1

1

1

1

1

1

1

Polycarbonate
(Thermoplastic)

2

1

3

2

2

2

2

3

1

302/304
Stainless Steel

2

1

3

1

1

1

1

2

1

Polyvinyl
Chloride (PVC)

1

1

1

1

1

1

1

3

1

Polypropylene
(Thermoplastic)

1

1

1

1

1

1

1

2

1

Polyester

1

1

2

1

1

1

1

2

1

Rubber
(Thermoplastic)

2

2

3

2

2

1

1

3

2

Phenolic
(Thermoset)

2

1

2

1

1

1

1

1

1

ABS
(Thermoplastic)

2

2

1

1

1

2

2

3

1

Material

Chemical resistance factor
1 – Completely resistant — Good to excellent for general use when exposed to these factors.
2 – Resistance is fair to good — Recommended for limited service when exposed to these factors.
3 – Slow attack. Not recommended for use when exposed to these factors.
*The chemical resistance factor represents general applications. Additional testing is required to determine resistance to chemicals in specific environments.

Terms describing material enhancements
Thermoplastic: Material treated for UV stability to increase tensile strength and decrease discoloration when exposed to UV radiation.
Manufactured by injection molding. Superior resistance to impacts, chemical and solvent attack.
Thermoset: Flame resistant material with dimensional stability. Manufactured by compression molding.
Glass Filled: Glass-filled material (most commonly nylon) yields increased material rigidity and permits operation at a higher temperature.
Nickel-Plated: Plating of steel or brass with nickel to increase the corrosion-resistant properties of the metal component.
Zinc-Plated: Plating of cold-rolled steel with zinc to increase the corrosion-resistant properties of the metal component or casing.

O-26

www.arrowhart.com

NEMA & IP Enclosures
NEMA Enclosure Ratings
Device Locations

Protection From

Indoors or
Outdoors

Indoors
Limited amounts of falling dirt

NEMA Type 1

Limited amounts of falling dirt and dripping water

NEMA Type 2

Rain, sleet, falling dirt, windblown dust, damage from ice formation

Outdoors with external
mechanisms

NEMA Type 3

Rain, sleet, falling dirt, damage from ice formation

NEMA Type 3R

Rain, sleet, windblown dust, ice laden operation possible

NEMA Type 3S

Windblown dust and rain, splashing water, hose-directed water,
damage from ice formation

NEMA Type 4

Corrosion, windblown dust and rain, splashing water, hose-directed water,
damage from ice formation

NEMA Type 4X

Falling dirt and settling airborn dust, lint, fibers and dripping non-corrosive liquids

NEMA Type 5

Hose-directed water, entry of water during occasional short-term
limited depth submersion, damage from ice formation

NEMA Type 6

Hose-directed water, entry of water during long-term limited depth submersion,
damage from ice formation

NEMA Type 6P
NEMA Type 7

Class I, Division 1, groups A,B,C or D hazardous locations
(as defined by NEC®, NFPA 70)

(commonly referred to
as explosion-proof)

NEMA Type 8

Class I, Division 1, groups A,B,C or D hazardous locations
(as defined by NEC®, NFPA 70)

(commonly referred to
as oil-immersed)

NEMA Type 9

Class II, Division 1, groups E, F and G hazardous locations
(as defined by NEC®, NFPA 70)

(commonly referred to
as dust-ignition-proof)

Meets applicable requirements of the Mine Safety & Health Administration,
30 CFR, Part 18

NEMA Type 10
NEMA Type 12
NEMA Type 12K

Circulating dust, falling dirt, dripping non-corrosive liquids
Dust, spraying of water, oil and non-corrosive coolant

NEMA Type 13

IP Enclosure Ratings
Second Digit - protection
against penetration of liquids

First Digit -

IP_0
Nonprotected

protection against
persons touching &
ingress of solid
objects

IP_1

IP_2

Vertical
Falling of
falling of
water drops
water drops at angle up
to 15º from
vertical

IP_3
Spraying
water (rain)
at angle up
to 60º from
vertical

IP_4
Splashing
water
from any
direction
(360º)

IP0_

Without protection

IP00

IP1_

Touching with hand & solid
objects > 50mm dia.

IP10

IP11

IP12

IP2_

Touching with finger & solid
objects > 12mm dia.

IP20

IP21

IP22

IP23

IP3_

Touching with tools, wires, etc.
> 2.5mm thick & solid objects
> 2.5mm dia.

IP30

IP31

IP32

IP33

IP34

IP40

IP41

IP42

IP43

IP44

IP4_

IP5_

IP6_

Touching with tools, wires, etc.
> 1mm thick & solid objects
> 1mm dia.
Unlimited protection against
contact with live parts &
damaging dust deposits
Unlimited protection against
contact with live parts & any
dust penetration

IP54

IP50

IP_5
Water jets
from any
direction
(360º)

www.arrowhart.com

Power
jetting
water

IP_7

IP_8

Temporary
immersion
in water

Continuous
immersion
in water

IP67

IP68

IP55

IP65

IP60

IP_6

IP66

O-27

NEMA & IP Enclosures
Enclosure Type Cross Reference: NEMA/UL/CSA
NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEMA Standards Publication No.
250-1991, Enclosures for Electrical
Equipment (1000V max.)

UNDERWRITERS LABORATORIES UL50
Standard for Enclosures for
Electrical Equipment (10th Edition)

CANADIAN STANDARDS
ASSOCIATION
CAN/CSA C22.2 No. 94-M91
Special Purposes Enclosures

Intended Use and Description
An enclosure is a surrounding case that
provides personnel with protection against
incidental contact with enclosed equipment,
and simultaneously protects enclosed
equipment against specific environmental
conditions.

Intended Use and Description
An enclosure is a surrounding case that
protects equipment enclosed within against
incidental contact, as well as specific
environmental conditions. A complete
enclosure shall be provided for all live parts
that may be housed in it. Such an enclosure
shall be tight and come with a means for
mounting, unless it’s designed for a special
installation, for example, a cast metal
junction or pull-box intended for installation
in poured concrete.

Intended Use and Description
Enclosures are constructed to protect
against specific environmental conditions,
as well as accidental contact with the
equipment enclosed within.

Type 1 - Enclosures are intended for indoor
use primarily to protect against limited
amounts of falling dirt.

Type 1 - Enclosures are intended for
indoor use primarily to protect
against limited amounts of falling dirt.

Type 1 - (There is no CSA equivalent.)

Type 2 - Enclosures provide a degree of
protection, mainly indoors, against limited
amounts of dripping water or falling dirt.

Type 2 - Enclosures provide a degree of
protection, mainly indoors, against limited
amounts of dripping water or falling dirt.

Type 2 - Enclosures are designed to provide
protection, primarily indoors, against
dripping and small amounts of splashing of
non-corrosive liquids, and dirt.

Type 3 - Enclosures, intended primarily for
use outdoors, protect against rain, sleet,
wind-blown dust, and damage from external
ice formation.

Type 3 - Enclosures, intended primarily for
use outdoors, protect against rain, sleet,
wind-blown dust, and damage from external
ice formation.

Type 3 - Enclosures, designed for both
indoor and outdoor use, protect against rain
and snow, and remain undamaged by the
external formation of ice.

Type 3R - Enclosures provide protection
primarily against rain, sleet, and damage
from external ice formation.

Type 3R - Used primarily outdoors for
protection against rain, sleet, and exterior
damage caused by the formation of ice.

Type 3R - Enclosures used both indoors and
out for protection against rain and snow,
remaining undamaged by exterior ice
formation.

Type 3S - Enclosures protect primarily
against rain, sleet, and wind-blown dust, and
enable external mechanisms to operate
efficiently even when ice laden.

Type 3S - Used primarily outdoors for
protection against rain, sleet, and windblown dust, and to enable exterior
mechanisms to operate when ice laden.

Type 3S - Enclosures used both indoors and
out for protection against rain, snow, and
airborne dust, and enable external
mechanisms to operate efficiently even when
ice laden.

Type 4 - Enclosures provide protection, both
indoors and out, against wind-blown dust
and rain, splashing or hose-directed water,
and ice damage.

Type 4 - For indoor and outdoor use to
protect against wind-blown dust and rain,
splashing or hose-directed water, and
damage caused by exterior ice formation.

Type 4 - Enclosures used both indoors and
out for protection against rain, snow,
airborne dust, and both splashing and hosedirected water, remaining undamaged by
exterior ice.

O-28

www.arrowhart.com

NEMA & IP Enclosures
Enclosure Type Cross Reference: NEMA/UL/CSA
(con't)

(con't)

(con't)

NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEMA Standards Publication No.
250-1991, Enclosures for Electrical
Equipment (1000V max.)

UNDERWRITERS LABORATORIES UL50
Standard for Enclosures for Electrical
Equipment (10th Edition)

CANADIAN STANDARDS
ASSOCIATION
CAN/CSA C22.2 No. 94-M91
Special Purposes Enclosures

Intended Use and Description
Type 4X - Enclosures used both indoors and
out to protect against corrosion, wind-blown
dust and rain, splashing or hose-directed
water, and damage caused by exterior ice
formation.

Intended Use and Description
Type 4X - For protection indoors and out
from corrosion, wind-blown dust and rain,
splashing or hose-directed water, and
damage caused by exterior ice formation.

Intended Use and Description
Type 4X - Enclosures used both indoors and
out for protection against rain, snow,
airborne dust, and both splashing and hosedirected water, remaining undamaged by
exterior ice formation.

Type 5 - Enclosures used primarily indoors
to provide protection against airborne dust
and dirt, and non-corrosive liquids.

Type 5 - Used primarily indoors for
protection against airborne dust or dirt, and
non-corrosive liquids.

Type 5 - Enclosures exclusively for indoor
use, providing protection against dripping
and light splashing of non-corrosive liquids,
as well as airborne dust, lint, fibers, and
filings.

Type 6 - Enclosures provide protection both
indoors and out against hose-directed water,
water entry during occasional short-term
submersion at low-pressure depths, and
damage caused by exterior ice formation.

Type 6 - For protection indoors and out
against hose-directed water, water entry
during occasional short-term submersion at
low-pressure depths, and damage caused
by exterior ice formation.

Type 6 - Enclosures used both indoors and
out for protection against water entry during
occasional short-term submersion at lowpressure depths, remaining undamaged by
exterior ice formation.

Type 6P - Enclosures protect both indoors
and out against hose-directed water, water
entry during long-term submersion at lowpressure depths, and ice damage.

Type 6P - For protection indoors and out
against hose-directed water, water entry
during long-term submersion at low-pressure
depths, and damage caused by exterior ice
formation.

Type 6P - Enclosures for use both indoors
and out for protection against water entry
during long-term submersion at low-pressure
depths. In addition, it provides corrosion
resistance over extended periods of time
and remains undamaged by exterior ice
formation.

Type 12 - Enclosures used primarily indoors
to protect against airborne dust or dirt, and
non-corrosive liquids.

Type 12 - Used primarily indoors to protect
against airborne dust and dirt, and noncorrosive liquids.

Type 12 - Enclosures exclusively for indoor
use, providing protection against airborne
dust, lint, fibers, and filings, as well as
dripping and light splashing of non-corrosive
liquids. These enclosures are not provided
with knockouts.

Type 12K - Enclosures with knockouts are
used primarily indoors for protection against
airborne dust and dirt, and non-corrosive
liquids.

Type 12K - Used primarily indoors to protect
against dust and dirt, and non-corrosive
liquids.

Type 12K - Enclosures provided with
knockouts and used exclusively indoors for
protection against airborne dust, lint, fibers,
and filings, as well as dripping and light
splashing of non-corrosive liquids.

Type 13 - Enclosures used primarily indoors
to protect against dust, as well as accidental
spraying by water, oil, or non-corrosive
coolants.

Type 13 - Used primarily indoors to protect
against dust, as well as accidental spraying
by water, oil, or non-corrosive coolants.

Type 13 - Enclosures exclusively for indoor
use, providing protection against airborne
dust, lint, fibers, and filings, as well as from
seepage and spraying of non-corrosive
liquids, including oils and coolants.

www.arrowhart.com

O-29

NAFTA Compliant
Products that are identified as NAFTA compliant may qualify under the Buy
American Act or ARRA program guidelines. Consult specific project guidelines
and compliance requirements to assure suitability for your project needs.
Buy American Act (US Code, Title 41, Section 10 (a-d))
The Buy American Act (often BAA, not to be confused with the Buy America (no
"n") Act) applies to all U.S. federal government agency purchases of goods over
certain contract thresholds. The BAA restricts purchases of supplies and
construction materials to domestic products, unless an exception or waiver
applies. Unmanufactured products must be mined or produced in the United
States. There is a two-part test for manufactured articles: (1) article must be
manufactured in the United States, and (2) cost of U.S. components must exceed
50% of the cost of all components in the item. Note: this calculation does not
include labor and overhead for final assembly in the United States. The
component cost test is waived for commercial-off-the-shelf (COTS) items.
(FAR 25.001(c)(1). BAA waivers may be available, often at the discretion of the
contracting officer.

Buy American Provision, American Recovery and
Reinvestment Act (ARRA) (Section 1605)
ARRA Section 1605 establishes requirements for federal
government projects funded with stimulus monies: “None
of the funds appropriated or otherwise made available by
[the ARRA] may be used for a project for the construction,
alteration, maintenance, or repair of a public building or
public work unless all of the iron, steel, and manufactured
goods used in the project are produced in the United
States.” Iron and steel used as components or
subcomponents of other manufactured construction
materials do not need to be produced in the United
States. There is no requirement that components and
subcomponents be U.S.-origin provided the manufactured
construction material is “produced in the United States.”
(FAR 25.001(c)(4)) Section 1605 does not contain a
domestic cost requirement. However, the government has
not defined “produced” for purposes of the ARRA Buy
American provision. Many commentators have adopted
the “substantial transformation” test to determine whether
a manufactured article is “produced” in the United States
for purposes of Section 1605. Section 1605 contains a
requirement that the Buy American provision be applied in
a manner consistent with U.S. obligations under
international agreements. As a result, national treatment is
extended to products from countries with which the
United States has entered a free trade agreement (e.g.,
Canada, Mexico, Bahrain, Chile, etc.) and to products
from countries that have signed the WTO Government
Procurement Agreement. National treatment is also
extended to least developed countries (LDCs) (e.g.,
Bhutan, Mali, Zambia, etc.) but not to Caribbean basin
countries (e.g., Belize, Haiti, Bahamas, etc.).

NAFTA compliant products meet specifications at time of print. Product listing subject to change. For specific product details visit
www.arrowhart.com or email cwdmarketing@cooperindustries.com.

O-30

www.arrowhart.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:30
Create Date                     : 2010:03:30 14:12:57Z
Creator Tool                    : QuarkXPress(R) 7.2
Modify Date                     : 2010:05:17 10:34:31-04:00
Metadata Date                   : 2010:05:17 10:34:31-04:00
Producer                        : QuarkXPress(R) 7.2
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Format                          : application/pdf
Title                           : Layout 1
Document ID                     : uuid:f6e14612-01e2-604d-958b-726adbe7c84f
Instance ID                     : uuid:32f4fb39-fb4c-ea4a-9619-2267f2abf9e7
Page Count                      : 30
Creator                         : QuarkXPress(R) 7.2
EXIF Metadata provided by EXIF.tools

Navigation menu