CROSS REFERENCE GUIDE
2013 Building Code Update for Accessibility

This document provides a cross reference between the accessibility provisions of the 2010 California
Building Code and the 2013 California Building Code as adopted by the California Building Standards
Commission on January 24, 2013.
This guide is organized as follows:
• Provisions in the 2010 California Building Code (column one).
• Corresponding provisions in the 2013 California Building Code (column two).
• Commentary (column three).
Portions of the 2010 California Building Code, Chapter 11A not referenced in this document are either
duplicative, not as stringent or in conflict with 2013 Chapter 11B and are no longer adopted by the
Division of the State Architect – Access Compliance.

February 5th, 2013

2013 California Building Code Update for Accessibility
Cross Reference Guide – Accessibility provisions in the 2010 CBC to the 2013 CBC
Table of Contents
Chapter 11B - Accessibility to Public Buildings, Public Accommodations, Commercial Buildings
and Publicly Funded Housing
Section 1101B Scope ............................................................................................................................ 3
Section 1102B Definitions ...................................................................................................................... 4
Section 1103B Building Accessibility ..................................................................................................... 5
Section 1104B Accessibility for Group A Occupancies .......................................................................... 6
Section 1105B Accessibility for Group B Occupancies ........................................................................ 15
Section 1106B Accessibility for Group E Occupancies ........................................................................ 20
Section 1107B Factories and Warehouses .......................................................................................... 22
Section 1108B Accessibility for Group H Occupancies ........................................................................ 24
Section 1109B Accessibility for Group I Occupancies .......................................................................... 25
Section 1110B Accessibility for Group M Occupancies ........................................................................ 27
Section 1111B Accessibility for Group R Occupancies ........................................................................ 29
Section 1112B Reserved ..................................................................................................................... 34
Section 1113B Reserved ..................................................................................................................... 34
Section 1114B Facility Accessibility ..................................................................................................... 35
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) .......................................................... 37
Section 1116B Elevators and Platform (Wheelchair) Lifts .................................................................... 44
Section 1117B Other Building Components ......................................................................................... 48
Section 1118B Space Allowance and Reach Ranges .......................................................................... 56
Section 1119B Special Standards of Accessibility for Buildings with Historical Significance ................ 57
Section 1120B Floor and Levels .......................................................................................................... 58
Section 1121B Transportation Facilities ............................................................................................... 59
Section 1122B Fixed or Built-In Seating, Tables and Counters ............................................................ 63
Section 1123B Access to Employee Areas .......................................................................................... 64
Section 1124B Ground and Floor Surfaces.......................................................................................... 65
Section 1125B Storage ........................................................................................................................ 66
Section 1126B Vending Machines and Other Equipment ..................................................................... 67
Section 1127B Exterior Routes of Travel ............................................................................................. 68
Cross Reference Guide - 2010 CBC to 2013 CBC
Table of Contents

Page 1 of 106
th
February 5 2013

Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses) .................................. 70
Section 1129B Accessible Parking Required ....................................................................................... 71
Section 1130B Parking Structures ....................................................................................................... 74
Section 1131B Passenger Drop-Off and Loading Zones...................................................................... 75
Section 1132B Outdoor Occupancies .................................................................................................. 76
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel .................................... 78
Section 1134B – Accessibility for Existing Buildings ............................................................................ 89
Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings with Historical
Significance ......................................................................................................................................... 94
Chapter 11C – Standards for Card Readers at Gasoline Fuel-Dispensing Facilities ................... 95
Chapter 11A – Housing Accessiblity
Section 1101A Application ................................................................................................................... 97
Section 1102A Building Accessibility ................................................................................................... 98
Section 1104A Covered Multifamily Dwellings ................................................................................... 100
Section 1106A Site and Building Characteristics ............................................................................... 101
Section 1109A Parking Facilities ....................................................................................................... 102
Section 1114A Exterior Ramps and Landings on Accessible Routes ................................................. 103
Division IV Dwelling Unit Features ..................................................................................................... 104
Division VI Site Impracticality Tests ................................................................................................... 106

Cross Reference Guide - 2010 CBC to 2013 CBC
Table of Contents

Page 2 of 106
th
February 5 2013

Section 1101B Scope
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

Section 1101B SCOPE

11B-107

Preserves reference to Chapter 1, Section
1.9.1.5 making the findings and
determinations rendered by a local
enforcement agency subject to ratification
through an appeals process.

1101B.1 General

N/A

Title only in 2010 CBC

1.

11B-101.1 General

General scoping for buildings and
facilities

2.

11B-103 Equivalent Facilitation

General scoping for equivalent facilitation

3.

11B-103 Equivalent Facilitation

General scoping for equivalent facilitation

1101B.2 Design

11B-101.1 General

General scoping for buildings and
facilities

1101B.3 Maintenance of
accessible features

11B-108 Maintenance of
Accessible Features

2010 ADAS addresses maintenance only
in advisory language; this section
maintains current CBC requirement.

1101B.4 Dimension
Conventions.

11B-104.1 Dimensions

Figure 11B-104 from ADA provides
graphic conventions for figures.

1101B.5 Constructing and
manufacturing tolerances.

11B-104.1.1 Construction and
Manufacturing Tolerances

All dimensions are subject to conventional
industry tolerances except where the
requirement is stated as a range with
specific minimum and maximum end
points.

1101B.6 Commercial facilities
located in private residences.

11B-245 Commercial Facilities
Located in Private
Residences

2010 ADA and 2010 CBC are equivalent.
This is a scoping provision and has been
included in Chapter 11B Division 2.

1101B.7 Provisions for Adults

11B-102 Dimensions for Adults
and Children

ADA and CBC equivalent.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1101B Scope

Page 3 of 106
5 February 2013

Section 1102B Definitions
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1102B DEFINITIONS

11B-106 Definitions

Because California amendments to the
ADA Model Code language will be in
italics, defined terms within the code
language will not be shown italicized.

• 11B-106.5 Defined Terms
• Chapter 2, Section 202

To conform to the format of the 2013
CBC, definitions will be located in Chapter
2, with a list of defined terms appearing in
11B-106.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1102B - Definitions

Page 4 of 106
5 February 2013

Section 1103B Building Accessibility
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1103B.1 SCOPE

11B-101.1 General

This section establishes that the
requirements for accessibility are found in
Chapter 11B and applies them to sites,
facilities, buildings and elements to the
extent set forth in the regulations.

Second paragraph

•
•
•
•

11B-403.1 General
11B-403.5 Clearances
11B-403.5.1 Clear Width
11B-403.5.2 Clear Width at
Turns
• 11B-206.6 Elevators

Exception 1

• 11B-203.4 Limited Access
Spaces
• 11B-203.5 Machinery Spaces
• 11B-206.2.8 Exceptions 1, 2
&3

Exception 2

11B-206.2.3

Both 2010 CBC and ADA do not require
ramp or elevator access to above or
below the first floor for certain small
facilities as noted in Exceptions 2.1 and
2.2.

Exception 2.1

11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 1

The specific 2010 CBC Exception
language for small office buildings and
passenger vehicle service stations has
been added to clarify that the second
condition in Exception 1 does not apply.

Exception 2.2

11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 1

The conditional language from the 2010
CBC Exception has been added to the
ADA language.

Third Paragraph

11B-213.2 Toilet Rooms and
Bathing Rooms

This section requires accessible toilet and
bathing facilities be provided on an
accessible route

Fifth Paragraph

11B-206.2.3.1 Stairs &
Escalators in Existing
Buildings
11B-206.2.3.2 Distance to
Elevators

This section requires accessible route
when stair or escalator is provided in
alteration
This section from 2010 CBC for maximum
distance to elevators.

1103B.2 Distance to Elevators

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1103B Building Accessibility

Page 5 of 106
5 February 2013

Section 1104B Accessibility for Group A Occupancies
2013 CBC Chapter 11B
11B-101.1 General

Comments

11B-219.2 Required Systems

Scoping for assistive listening systems;
amends model code language to remove
implied exception when audible
communications is not integral to the use
of the space.

Exception.

11B-219.2 Required Systems,
Exception: Paging, and
background music

Scoping for assistive listening systems;
amends model code language to narrow
scope of exception and maintain current
2010 CBC exception for paging and
background music systems.

1. Number of personal
receivers required

11B-219.3 Receivers

Scoping for number of receivers required;
amends model code language to maintain
current 2010 CBC requirements.

2. Types of listening systems

11B-706 Assistive Listening
Systems

Technical requirements for assistive
listening systems. Model code language
provides more detailed technical
performance specifications.

3. Location

11B-219.4 Location

Scoping for location of assistive listening
systems; amends model code with current
2010 CBC provisions regarding location
when not all seats are covered by the
assistive listening system.

4. Signage

• 11B-216.10 Assistive
Listening Systems
• 11B-703.5 Visual Characters
• 11B-703.7.2.4 Assistive
Listening Systems

Scoping for signage required for
availability of assistive listening systems.

5. Fees and Charges

N/A

Operational issue not enforceable by
building officials; current 2010 CBC
provisions not carried forward.

6. Permanent and Portable
Systems

11B-219.5 Permanent and
Portable Systems.

Scoping for permanent and portable
assistive listening systems; amends
model code with current 2010 CBC
provisions regarding permanent and
portable assistive listening systems.

11B-221 Assembly Areas

Scoping for assembly areas.

2010 CBC Chapter 11B

1104B.1 General

1104B.2 Assistive listening
systems in assembly areas.

1104B.3 Auditoriums, assembly
halls, theaters and related
facilities.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

This section establishes that the
requirements for accessibility are found in
Chapter 11B and applies them to sites,
facilities, buildings and elements to the
extent set forth in the regulations.

Technical requirements for assistive
listening systems signage

Page 6 of 106
5 February 2013

2013 CBC Chapter 11B
11B-221.1 General

Comments

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1104B.3.2 Accessibility to key
facilities.

11B-206.2.4 Spaces and
Elements

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.

1104B.3.3 Variety of locations.

• 11B-221.2 Wheelchair
Spaces
• 11B-221.2.1.2 Luxury Boxes,
Club Boxes, and Suites in
Arenas, Stadiums and
Grandstands.
• 11B-221.2.1.3 Other Boxes
• 11B-221.2.1.4 Team or Player
Seating
• 11B-221.2.3 Lines of Sight
and Dispersion

Scoping for accessible seating dispersion.

1104B.3.4 Wheel Chair Spaces
1. Number of such spaces is
as shown in table 11B-1.

• 11B-221.2 Wheelchair
Spaces
• Table 11B-221.2.1.1 Number
of Wheelchair Spaces in
Assembly Areas

Scoping for the minimum number of
wheelchair spaces.

1104B.3.4 Wheel Chair Spaces
2. The ground or . . .

11B-802.1.1 Floor or Ground
Surface

Technical requirements for level floor or
ground surface at wheelchair spaces.
Slopes of 1:48 maximum are permitted.

2010 CBC Chapter 11B

1104B.3.1 Seating

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Scoping for wheelchair spaces,
companion seats, designated aisle seats
and semi-ambulant seats.

Page 7 of 106
5 February 2013

2010 CBC Chapter 11B

1104B.3.5 Placement of
wheelchair locations.

2013 CBC Chapter 11B
• 11B-221.2.2 Integration
• 11B-221.2.1.2 Luxury Boxes,
Club Boxes, and Suites in
Arenas, Stadiums and
Grandstands.
• 11B-221.2.1.3 Other Boxes
• 11B-221.2.1.4 Team or Player
Seating
• 11B-221.2.3 Lines of Sight
and Dispersion

Comments

Scoping for the number of wheel chair
spaces and their integration into the
seating plan, dispersion, sight lines and
other locational factors.

• 11B-802.1.4 Approach

• 11B-207 Accessible Means of
Egress

Technical requirements for adjoining
accessible route.

• 11B-221.3 Companion Seats

Scoping for companion seats at wheel
chair spaces.

Exception 1

11B-221.2.3.1 Horizontal
Dispersion, Exceptions

Scoping for dispersion where 300 or less
seating capacity.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-802.1 Wheelchair
Spaces

Technical requirements for size of
wheelchair spaces.

• 11B-802.1.4 Approach

Technical requirements for wheel chair
spaces to adjoin an accessible route.

1104B.3.7 Readily removable
seats.

N/A

Not allowed under the 2010 ADAS,
current 2010 CBC provisions not carried
forward.

1104B.3.8 Seating for semiambulant individuals.

• 11B-221.1 General
• 11B-221.6 Semi-Ambulant
Seats

Scoping for semi-ambulant seats; model
code has been amended to include 2010
CBC requirements.

• 11B-802.5 Semi-Ambulant
Seats

Technical requirements for semi-ambulant
seats.

1104B.3.6 Size of wheelchair
location.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Page 8 of 106
5 February 2013

Comments

1104B.3.9 Designated aisle
seats.

2013 CBC Chapter 11B
• 11B-802.4 Designated Aisle
Seats
• 11B-802.4.1 Armrests
• 11B-802.4.2 Identification

1104B.3.10 Life safety.

N/A

Compliance with fire and life safety
requirements for all seats is mandated by
Chapter 10. Redundant 2010 CBC
provision not carried forward.

1104B.3.11 Access to
performing areas.

11B-206.2.6 Performance
Areas

Scoping for access to performance areas
including ancillary areas.

1104B.3.12 Stages, enclosed
and unenclosed platforms and
orchestra pits.

11B-206.7.1 Performance
Areas and Speakers
Platforms

Scoping to allow platform lifts to access
performance areas and speaker’s
platforms.

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• Chapter 2 – Section 202

Definition of Workstation

• 11B-203.9 Employee Work
Areas

Scoping for Employee Work Area

• 11B-206.2.4 Spaces and
Elements
• 11B-904.4 Sales and Service
Counters

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.

• 11B-206.2.4 Spaces and
Elements
• Division 6: Plumbing
Elements and Facilities

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements, including toilet
facilities.

2010 CBC Chapter 11B

1104B.3.13 Ticket booths.

1104B.3.14 Miscellaneous
areas.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Technical requirements for designated
aisle seats.

Page 9 of 106
5 February 2013

2013 CBC Chapter 11B
N/A

Comments

1104B.4.1 Spectator Seating

• 11B-221.1 General
• 202 DEFINITIONS –
Assembly Area

Scoping for accessible seating

1104B.4.2 Ticket Booths

• Chapter 2 – Section 202

Definition of Workstation

• 11B-203.9 Employee Work
Areas

Scoping for Employee Work Area

• 11B-206.2.4 Spaces and
Elements
• 11B-904.4 Sales and Service
Counters

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.

11B-206.2.4 Spaces and
Elements

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.

• 11B-206.2.4 Spaces and
Elements

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.

• 11B-302.1 General, Exception

Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant” with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.

2010 CBC Chapter 11B

1104B.4 Stadiums, grandstands,
bleachers, athletic pavilions,
gymnasiums, and miscellaneous
sports-related facilities.

1104B.4.3 Participation Areas

1. Tennis, racquetball and
handball courts.

• 11B-303.1 General, Exception

2. Gymnasium floor areas
and general exercise rooms.

Title only in 2010 CBC.

• 11B-206.2.4 Spaces and
Elements

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.

• 11B-302.1 General, Exception

Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant” with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.

• 11B-303.1 General, Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Page 10 of 106
5 February 2013

2010 CBC Chapter 11B

3. Basketball, volleyball and
badminton courts and
bowling lanes.

2013 CBC Chapter 11B
• 11B-206.2.4 Spaces and
Elements

Comments

Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.

• 11B-303.1 General, Exception

Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant” with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.

• 11B-242 Swimming Pools,
Wading Pools, and Spas

Scoping for swimming pools, wading
pools, and spas.

• 11B-1009 Swimming Pools,
Wading Pools, and Spas

Technical requirements for swimming
pools, wading pools, and spas.

N/A

Title only in 2010 CBC.

4.1.1. Seat shall be
rigid . . .

11B-1009.2.4 Seat

Technical requirements for a rigid seat.

4.1.2. Seat height

11B-1009.2.4 Seat

Technical requirements for seat height.

4.1.3. Armrests

11B-1009.2.6 Footrests and
Armrests

Model code amended to add technical
requirements for two armrests.

4.1.4. Back support

11B-1009.2.4 Seat

Technical requirements for back support.

4.1.5. Occupant
restraint

11B-1009.2.4 Seat

Model code amended to add technical
requirements for seat restraint.

4.2 Be capable of . . .

11B-1009.2.7 Operation

Technical requirement for unassisted
operation.

4.3 Be stable and . . .

11B-1009.2.7 Operation

Model code amended to add technical
requirements for stable operation without
unintended movement.

4.4 Be designed to . . .

11B-1009.2.9 Lift Capacity

Technical requirements for lift capacity,
300 lbs. minimum.

4.5 Be positioned so . . .

11B-1009.2.1 Pool Lift Location
Exception 3

Technical requirements for water level.

4.6 Lower the operator .
..

11B-1009.2.8 Submerged
Depth

Technical requirements for submerged
depth.

• 11B-302.1 General, Exception

4. Swimming pool deck
areas . . .

4.1 Have a seat . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Page 11 of 106
5 February 2013

2013 CBC Chapter 11B
• 11B-206.2.2 Within a Site

Comments

• 11B-206.4 Spaces and
Elements

Scoping for accessible route connecting
entrances to accessible spaces and
elements within the building or facility.

1104B.4.4 Clubrooms.

• 11B-201.1 Scope
• 11B-222 Dressing, Fitting,
and Locker Rooms
• 11B-222.1 General

General scoping requirements.
Scoping based on use for Dressing,
Fitting, and Locker rooms.

1104B.4.5 Sanitary and locker
facilities.

• 11B-222 Dressing, Fitting,
and Locker Rooms
• 11B-222.1 General

Scoping based on use for Dressing,
Fitting, and Locker rooms.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities

N/A

Title only in 2010 CBC.

• 11B-201.1 Scope
• 11B-226 Dining Surfaces and
Work Surfaces
• 11B-226.1 General

General scoping requirements.
Scoping for dining and work surfaces

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

2010 CBC Chapter 11B

5. Athletic team . . .

1104B.5 Dining, banquet and bar
facilities.
1. General.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Scoping for accessible route connecting
accessible buildings, facilities, elements,
and spaces on the same site.

Page 12 of 106
5 February 2013

2013 CBC Chapter 11B
• 11B-206.2.2 Within a Site

Comments

• 11B-206.4 Entrances

Scoping for entrances for buildings or
facilities .

• 11B-206.2.5 Restaurants and
Cafeterias

Scoping for all dining areas, included
raised and sunken areas.

• 11B-303.5 Warning Curbs,
Exception

Scoping for warning curbs and guard or
handrails at the open edges of raised or
sunken areas.

• 11B-226.1 General

Scoping for number of wheelchair spaces
at dining seating to be 5%.

• 11B-226.2 Dispersion

• 11B-226.3 Dining Surfaces
exceeding 34” in height.

Scoping for dispersion of wheel chair
spaces within seating for each type of
functional area.
Scoping for portion of dining surface of
60”in length

• 11B-403.5.1 Clear Width,
Exception 4

Technical requirements for clear width at
aisles.

• 11B-902.3 Height, Exception

Technical requirement for height of dining
and work surfaces.

• 11B-403.5.1 Clear Width,
Exception 4

Technical requirement for clear width at
aisles.

• 11B-227.4 Food Service
Lines

Scoping for self-service shelving at food
service lines.

• 11B-904.5 Food Service
Lines

Technical requirements for food service
aisles.

6. Tableware and condiment
areas.

11B-904.5.1 Self-Service
Shelves and Dispensing
Devices

Technical requirements for dispensing
tableware, dishware, condiments, food
and beverages.

7. Restrooms

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities

8. Food preparation areas.

• Chapter 2 – Section 202

Definition of workstation

• 11B-203.9 Employee Work
Areas

Scoping for access to employee work
areas.

N/A

Title only in 2010 CBC.

2010 CBC Chapter 11B

2. Entrance.

3. Raised or sunken areas.

4. Seating.

5. Food service aisles.

1104B.6 Religious facilities.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Scoping for accessible route connecting
accessible buildings, facilities, elements,
and spaces on the same site.

Page 13 of 106
5 February 2013

2013 CBC Chapter 11B
11B-244 Religious Facilities

Comments

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1104B.6.2. Sanctuary.

11B-244 Religious Facilities

Scoping for religious facilities including
various areas within facility.

1104B.6.2.1. Wheelchair seating
...

11B-221.2.1.1 General Seating

Scoping for number of wheelchair spaces
required.

1104B.6.2.2. Wheelchair access
...

11B-206.2.6 Performance
Areas

Scoping for direct accessible route to
performance and ancillary areas.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-206.4 Spaces and
Elements

Scoping for accessible routes connecting
entrances to accessible spaces and
elements within the building or facility.

• 11B-206.2.6 Performance
Areas

Scoping for direct accessible route to
performance and ancillary areas..

1104B.6.4. Classrooms and
offices.

11B-206.4 Spaces and
Elements

Scoping for accessible route connecting
entrances to accessible spaces and
elements within the building or facility.

1104B.6.5. Sanitary facilities.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities

2010 CBC Chapter 11B

1104B.6.1. General.

Exception.

Exception. In existing
buildings . . .

1104B.6.3. Assembly areas.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104B Accessibility for Group A Occupancies

Model code has been amended to include
scoping for religious facilities.

Page 14 of 106
5 February 2013

Section 1105B Accessibility for Group B Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

Section 1105B Accessibility for
Group B Occupancies

11B-101.1 General

General scoping for buildings and
facilities

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 3

• 11B-303 Changes in Level

Technical requirements for changes in
level.

• 11B-402.2 Components.

Technical requirements for accessible
routes

1105B.1 General.

N/A

Title only in 2010 CBC.

1105B.2 Group B occupancies.

11B-221 Assembly Areas

Based on use as an assembly area
Scoping for Assembly Areas will apply.

1105B.3 Office buildings and
personal and public service
facilities.

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

1105B.3.1 Facilities covered.

N/A

Title only in 2010 CBC.

• 11B-106.5 Definitions
• Section 202 DEFINITIONS

Definition of Place of Public
Accommodation.

• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.

1. All types of . . . business
professional offices, . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1105B Accessibility for Group B Occupancies

Page 15 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

2. All types of sales
establishments . . .

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.

3. All personal and public
service facilities, . . .

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.

• 11B-217.4.6 Hospitals

Scoping for hospitals

• 11B-231 Judicial Facilities

Scoping for courtrooms

• 11B-232 Detention Facilities
and Correctional

Scoping for detention and correctional
facilities.

• 11B-611 Washing Machines
and Clothes Dryers

Technical requirements for laundry
equipment.

• 11B-707.9.2 Point-of-sale
devices at check stands and
sales and services counters.

Technical requirements for point-of-sale
devices at check stands and sales and
service counters.

• 11B-226 Dining Surfaces and
Work Surfaces

Scoping for dining surfaces and work
surfaces.

• 11B-901.1 Scope

Technical requirements for built-in
elements.

Chapter 2 – Section 202

Definition of Place of Public
Accommodation.

• 11B-201 Application

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

• 11B-201.1 Scope

Types of facilities listed in 2010 CBC
covered under this division.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

• 11B-201 Application

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

4. . . . areas used for
businesses transactions with
the public . . .

1105B.3.2 Business and
professional offices.
1. Client and visitor areas
and office areas, together
with related toilet rooms.

2. Conferences rooms,
counseling rooms or cubicles
and similar areas.

• 11B-201.1 Scope

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1105B Accessibility for Group B Occupancies

Types of facilities listed in 2010 CBC
covered under this division.

Page 16 of 106
5 February 2013

2010 CBC Chapter 11B

3. Employee work areas
shall have a minimum of 36
inch clear width access . . .

4. Professional medical and
dental offices . . .

2013 CBC Chapter 11B

Comments

• 11B-203.9 Employee Work
Areas.

Scoping for employee work areas.

• 11B-403 Walking Surfaces

Technical requirements for walking
surfaces part of an accessible route.

• 11B-403.5 Clearances,
Exception

Technical requirements for clearances
within employee work areas.

• 11B-403.5.1 Clear Width

Technical requirements for clear width of
walking surfaces.

• 11B-223.4 Professional
Offices of Health Care
Providers

Scoping for offices of health care
providers.

• 11B-805 Medical Care and
Long Term Care Facilities
1105B.3.3 Personal and public
service facilities.
1. Client and visitor areas
and office areas, together
with related toilet rooms.

2. Employee work areas
shall have a minimum of 36
inch clear width access . . .

3. Automated teller
machines . . . shall be on an
accessible route . . .
1105B.3.4 Public utility facilities.

Chapter 2 – Section 202

Definition of Place of Public
Accommodation.

• 11B-201 Application

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

• 11B-201.1 Scope

Types of facilities listed covered under
this division.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

• 11B-203.9 Employee Work
Areas.

Scoping for employee work areas.

• 11B-403 Walking Surfaces

Technical requirements for walking
surfaces part of an accessible route.

• 11B-403.5 Clearances,
Exception

Technical requirements for clearances
within employee work areas.

• 11B-403.5.1 Clear Width

Technical requirements for clear width of
walking surfaces.

11B-206.2.2 Within a Site.

Scoping requirement for an accessible
route to connect accessible buildings,
facilities, elements and spaces on a site.

Chapter 2 – Section 202

Definition of Place of Public
Accommodation.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1105B Accessibility for Group B Occupancies

Page 17 of 106
5 February 2013

2010 CBC Chapter 11B

1. Office areas, meetings
rooms and similar areas . . .

2013 CBC Chapter 11B

Comments

• 11B-201 Application

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.

• 11B-201.1 Scope

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

11B-206.2.2 Within a Site.

Scoping requirement for an accessible
route to connect accessible buildings,
facilities, elements and spaces on a site.

Exception 1. Facilities
located in operational
areas. . .

11B-203.5 Machinery Spaces

Scoping for accessible route at machinery
spaces.

Exception 2. . . .
unreasonable hardship, . .

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-201 Application

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed in the 2010 CBC
covered under this division.

2. Public tour areas, . . .

3. Visitor overlook facilities . .
.

• 11B-201.1 Scope

4. Where public parking is
provided . . .

1105B.3.5 Police department,
law enforcement, Fire
Department facilities and
courtrooms.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

11B-208 Parking Spaces

Scoping requirements for parking.

11B-502 Parking Spaces

Technical requirements for accessible
parking.

• 11B-230.1 Judicial Facilities
• 11B-232 Detention Facilities
and Correctional Facilities

Scoping for judicial and correctional
facilities.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1105B Accessibility for Group B Occupancies

Page 18 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

• 11B-231.4 Visiting Areas

Scoping for visiting areas.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

2. Detention area visitor
rooms . . .

11B-232.5 Visiting Areas

Scoping for visiting areas.

3. At least one detention cell
...

• 11B-232 Detention Facilities
and Correctional Facilities
• 11B-807.2.4 Toilet and
Bathing Facilities

Scoping requirements for detention
facilities
Technical requirements for toilet and
bathing facilities provided as part of a cell.

4. Courtroom areas, . . .

• 11B-231.1 General

Scoping requirements for judicial facilities.

• 11B-808.4 Judges’ Benches
and Courtroom Stations.

Technical requirements for judges’
benches and courtroom stations.

• 11B-902 Dining Surfaces and
Work Surfaces

Technical requirements for work surfaces.

N/A

Title only in 2010 CBC.

• 11B-403 Walking Surfaces
• 11B-403.1 General

Technical requirements for walking
surfaces as part of an accessible route.

• 11B-403.5 Clearances
• 11B-403.5.1 Clear Width

Technical requirements for clear width.

• 11B-225.2 Storage

Scoping requirements for general storage
uses.
Scoping for self-service storage facilities.

1. Office areas, conference
rooms, . . .

1105B.3.6 Miscellaneous
general standards.
1. Circulation aisles and
pedestrian ways . . .

2. Storage areas . . .

• 11B-223.3 Self-Service
Storage Facilities

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1105B Accessibility for Group B Occupancies

Page 19 of 106
5 February 2013

Section 1106B Accessibility for Group E Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1106B.1 General.

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

Exception 1.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-226 Dining Surfaces and
Work Surfaces
• 11B-226.1 General
• 11B-226.2 Dispersion

Scoping for number and dispersion of
work surfaces.

• 11B-805.7 Built-in Cabinets
and Work Surfaces.
Exception 2.

Detailed scoping for laboratory
workstations requiring 5 percent but not
less than one to be accessible.

11B-902 Dining Surfaces and
Work Surfaces
• 11B-902.1 General
• 11B-902.2 Clear Floor or
Ground Space
• 11B-902.3 Height

Technical requirements for work surfaces.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1106B.2 Laboratory rooms. . . .
shall have at least one and at
least 5 percent of all
workstations accessible . . .

Exception.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1106B Accessibility for Group E Occupancies

Page 20 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1106B.3 Teaching facility
cubicles, study carrels, etc.

• 11B-226 Dining Surfaces and
Work Surfaces
• 11B-226.1 General
• 11B-226.2 Dispersion

Scoping for number and dispersion of
work surfaces.

• 11B-902 Dining Surfaces and
Work Surfaces
• 11B-902.1 General
• 11B-902.2 Clear Floor or
Ground Space
• 11B-902.3 Height

Technical requirements for work surfaces.

N/A

Title only in 2010 CBC.

•11B-201.1 Scope

General scoping for building and facility
accessibility

• 11B-225.2 Storage

Scoping for storage.

• 11B-227.3 Counters

Scoping for counters.
Technical requirements for book shelves.

3. Height of book shelves.

11B-225.2.3 Library Book
Stacks
• 11B-308.3 Side Reach
• 11B-308.3.1 Unobstructed,
Exception 3

4. Card catalogs and
magazine displays.

• 11B-308.2 Forward Reach
• 11B-308.3 Side Reach

Technical requirements for reach ranges.

5. Reading and study areas.

• 11B-226 Dining Surfaces and
Work Surfaces
• 11B-226.1 General
• 11B-226.2 Dispersion

Scoping for 5 percent of workstations to
comply with requirements.

• 11B-902 Dining Surfaces and
Work Surfaces
• 11B-902.1 General
• 11B-902.2 Clear Floor or
Ground Space
• 11B-902.3 Height

Technical requirements for work surfaces

11B-904.3.1 Check-Out Aisles

Technical requirements for check-out
aisles.

1106B.4 Library general use
areas.
1. General.

2. Open book stacks.

6. Check-out areas.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1106B Accessibility for Group E Occupancies

Technical requirements for book shelves.

Dispersion of work surfaces.

Page 21 of 106
5 February 2013

Section 1107B Factories and Warehouses
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

Factories and warehouses…..

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

• 11B-206.2.3 Multi-Story
Buildings and Facilities

Scoping for accessible route in Multi-Story
Buildings and Facilities

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

N/A

Title only in 2010 CBC.

1. Major or principle floor
areas shall be made
accessible.

• 11B-201 Application
• 11B-201.1 Scope
• 11B-203.9 Employee Work
Areas

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.

2. Office areas shall be
made accessible.

• 11B-201 Application
• 11B-201.1 Scope
• 11B-203.9 Employee Work
Areas

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.

3. Sanitary facilities serving
these facilities . . .

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

N/A

Title only in 2010 CBC.

1. Miscellaneous
warehousing areas . . .

11B-206.2.3 Multi-Story
Buildings and Facilities

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in Multi-Story
Buildings and Facilities

2. Office areas shall be
made accessible.

11B-203.9 Employee Work
Areas

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.

Exception

1107B.1 Factories.

1107B.2 Warehouses.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1107B Factories and Warehouses

Page 22 of 106
5 February 2013

2010 CBC Chapter 11B

3. Sanitary facilities serving
these facilities . . .

2013 CBC Chapter 11B

Comments

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1107B Factories and Warehouses

Page 23 of 106
5 February 2013

Section 1108B Accessibility for Group H Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1108B.1 General.

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1108B.2 Accessible sanitation
facilities.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

1108B.3 Accessible routes.

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

1108B.4 Accessible floors and
levels.

• 11B-206.2.3 Multi-Story
Buildings and Facilities

Scoping for accessible route in Multi-Story
Buildings and Facilities

• 11B-402 Accessible Routes

Technical requirements for accessible
routes.

1108B.5 Employee work areas.

11B-203.9 Employee Work
Areas

Scoping for accessible route in employee
work areas.

1108B.6 Accessible facilities
covered . . .

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1108B Accessibility for Group H Occupancies

Page 24 of 106
5 February 2013

Section 1109B Accessibility for Group I Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1109B.1 General.

11B-223 – Medical Care and
Long Term Care Facilities

Scoping for Medical Care and Long Term
Care Facilities

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-209 Medical and Long
Term Care Facilities

Scoping for accessible entrance with
passenger loading zone.

• 11B-503 Passenger Drop-Off
and Loading Zone

Technical requirements for passenger
drop-off and loading zones.

• 11B-223 Medical Care and
Long term Care Facilities

Scoping for patient bedrooms.

• 11B-805 Medical Care and
Long term Care Facilities

Technical requirements for patient
bedrooms.

• 11B-805.2.4 Toilet and
Bathing Rooms

Technical requirements for patient toilet
rooms.

1. Long-term care facilities . .
.

11B-223.3 Long Term Care
Facilities

Scoping for number of accessible rooms
in long term care facilities.

2. General purpose hospitals
...

11B-223.2.1 Facilities Not
Specializing in Treating
Conditions That Affect
Mobility.

Scoping for number of accessible rooms
in facilities not specializing in treating
conditions that affect mobility and general
hospital facilities.

3. Hospitals and
rehabilitation facilities that
specialize in treating
conditions affecting mobility .
...

11B-223.2.2 Facilities
Specializing in Treating
Conditions That Affect
Mobility

Scoping for number of accessible rooms
in facilities specializing in treating
conditions that affect mobility.

Exception 1.

11B-223.1.1.1 Area Alterations

Scoping for area alterations.

Exception 2.

11B-223.1.1.2 Individual
Alterations

Scoping for individual alterations.

N/A

Title only in 2010 CBC.

11B-805.2.3 Turning Space

Technical requirements for turning space
in patient bedroom.

Exception

1109B.2 Entrance.

1109B.3 Patient bedrooms and
toilet rooms.

1109B.4 Patient bedroom areas.
1. Each bedroom shall have
a turning space . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1109B Accessibility for Group I Occupancies

Page 25 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

2. Each bedroom shall have
a minimum clear floor space
...

11B-805.2.2 Beds

Technical requirements for clear space
along the full length of bed.

3. Each bedroom shall have
an accessible door . . .

11B-404.3 Manual Doors,
Doorways, and Gates

Technical requirements for doors,
doorways and gates.

1109B.5 Patient toilet rooms and
bathing facilities.

11B-805.2.4 Toilet and Bathing
Rooms

Technical requirements for patient toilet
rooms.

1109B.6 Diagnostic and
treatment areas.

11B-805.4 Examination,
Diagnostic and Treatment
Rooms.

Technical requirements for examination,
diagnostic and treatment rooms.

1109B.7 Waiting areas, offices
and sanitary facilities.

• 11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for toilet and bathing facilities.

1109B.8 Offices and suites.

• 11B-201 Application
• 11B-201.1 Scope

Scoping for newly designed, newly
constructed and altered portions of
existing buildings.

• 11B-402 Accessible Routes

Technical requirements for accessible
routes.

• 11B-203.9 Employee Work
Areas

Scoping for accessible route in employee
work areas.

• 11B-805.7 Built-in Cabinets
and Work Surfaces

Technical requirements for built-in
cabinets and work surfaces.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1109B Accessibility for Group I Occupancies

Page 26 of 106
5 February 2013

Section 1110B Accessibility for Group M Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1110B.1 Sales.

11B-227 Sales and Service

Scoping for sales and service facilities.

1110B.1.1 General areas.

• 11B-227 Sales and Service
• 11B-227.1 General

Scoping for sales and service facilities.

Exception 1

Not carried forward

This provision would lessen the level of
accessibility provided by the 2010 ADAS.

Exception 2

Not carried forward

This provision would lessen the level of
accessibility provided by the 2010 ADAS.

• 11B-227.2 Check-Out Aisles

Scoping for check-out aisles.

• 11B-904 Check-Out Aisles
and Sales and Service
Counters

Technical requirements for check-out
aisles and sales and service counters.

• 11B-203.9 Employee Work
Areas

Scoping for accessible route in employee
work areas.

• 11B-216.11 Check-Out Aisles

Scoping for ISA at check-out aisle.

• 11B-227.2 Check-Out Aisles

Scoping for check-out aisles.

• 11B-904.3 Check-Out Aisles

Technical requirements for check-out
aisles.
Requirement for number of accessible
check-out aisles.

1110B.1.2 Work areas.

1110B.1.3 Check stands.

• Table 11B-227.2 Check-Out
Aisles
1110B.1.4 Point-of-sale
machines.

• 11B-220.2 Point-of-Sale
Devices

Scoping for point-of-sale devices.

• 11B-707 Automatic Teller
Machine, and Fare Machines
and Point-of-Sale Devices

Technical requirements for automatic
teller machine, and fare machines and
point-of-sale devices.

1110B.1.5 Turnstiles.

11B-404.2.1 Revolving Doors,
Gates, and Turnstiles.

Technical requirements for revolving
doors, gates, and turnstiles.

1110B.1.6 Theft prevention
barriers.

11B-206.8 Security Barriers

Scoping for security barriers.

• 11B-206.4 Entrances

Scoping for accessible entrances.

• 11B-207 Accessible Means of
Egress

Scoping for accessible means of egress.

1. Each entrance and exit . .
.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1110B Accessibility for Group M Occupancies

Page 27 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

• 11B-206.8 Security Barriers

Scoping for security barriers.

• 11B-404.2.4.2 Doorways
without Doors or Gates,
Sliding Doors, and Folding
Doors

Technical requirements for doorways
without doors or gates, sliding doors, and
folding doors including openings.

• 11B-206.4 Entrances

Scoping for accessible entrances.

• 11B-207 Accessible Means of
Egress

Scoping for accessible means of egress

• 11B-404.2.4.2 Doorways
without Doors or Gates,
Sliding Doors, and Folding
Doors

Technical requirements for doorways
without doors or gates, sliding doors, and
folding doors including openings.

4. Where a clear
unobstructed opening . . .

Table 11B-404.2.4.1
Maneuvering Clearances at
Manual Swinging Doors and
Gates

Technical requirements for clearances at
manual swinging doors and gates.

5. Where a gate is used, the
level area . . .

Table 11B-404.2.4.1
Maneuvering Clearances at
Manual Swinging Doors and
Gates

Technical requirements for clearances at
manual swinging doors and gates.

6. Where a gate is used, the
bottom . . .

11B-404.2.10 Door and Gate
Surfaces.

Technical requirements for door and gate
surfaces.

7. The path of travel to and
through . . .

• 11B-307.5 Required Clear
Width

Technical requirements for obstructions
within accessible route.

• 11B-403.5.1 Clear Width

Technical requirements for clear width.

• 11B-307.5 Required Clear
Width

Technical requirements for obstructions
within accessible route.

• 11B-403.5.1 Clear Width

Technical requirements for clear width.

1110B.2 Miscellaneous general
standards.

N/A

Title only in 2010 CBC.

1110B.2.1 Circulation.

• 11B-225.2.2 Self-Service
Shelving

Scoping for self-service shelving.

• 11B-403.5.1 Clear Width

Technical requirements for clear width.

• 11B-206.4 Entrances

Scoping for accessible entrances.

• 11B-225 Storage

Scoping for storage.

2. Shopping cart barriers
located . . .

3. Where gates are used . . .

8. Interior and exterior traffic
barriers . . .

1110B.2.2 Storage areas.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1110B Accessibility for Group M Occupancies

Page 28 of 106
5 February 2013

Section 1111B Accessibility for Group R Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1111B.1 General.

11B-201.1, as excepted by 11B203.8

Scoping for residential facilities.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-206 Accessible Routes

Scoping for accessible routes.

• 11B-402 Accessible Routes

Technical requirements for accessible
routes.

• 11B-214 Washing Machines
and Clothes Dryers

Scoping for washing machines and
clothes dryers.

• 11B-611 Washing Machines
and Clothes Dryers

Technical requirements for washing
machines and clothes dryers.

• 11B-203.8 Residential
Facilities

Scoping for common use areas not on
accessible route.

• 11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 4.

Scoping for common use areas not on
accessible route in multi-story buildings.

• 11B-206.2.2 Within a Site

Scoping for accessible routes within a
site.

Exception

1111B.2 Public and common use
rooms or areas.

Exception: Where elevators
are not required . . .

1111B.3 Recreational facilities.

• 11B-1001 General
Technical requirements for recreational
facilities including swimming pools.
1111B.4 Hotels, motels, inns,
dormitories, resorts, homeless
shelters, halfway houses,
transient group homes and
similar places of transient
lodging.

• 11B-224 Transient Lodging
Guest Rooms

1111B.4.1 Available range of
accommodations.

• 11B-224.1.3 Range of
Accommodations

Scoping for transient lodging
accommodations .

• 11B-224.1.1 Alterations
Scoping for alterations.

Scoping for range of accommodations in
transient lodging facilities.

• 11B-224.5 Dispersion

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1111B Accessibility for Group R Occupancies

Page 29 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1111B.4.2 Guest rooms and
suites.

• 11B-224.2 Guest Rooms with
Mobility Features

Scoping number of rooms with mobility
and communication features.

• 11B-224.4 Guest rooms with
Communication Features

1111B.4.2.1 Spaces.

• 11B-806.2.4 Toilet and
Bathing Facilities

Technical requirements for toilet and
bathing facilities part of a guest room.

• 11B-201 Application

Scoping for required accessible spaces
within a guest room.

• 11B-201 Accessible Routes
1. The living area:

11B-806.2.1 Living and Dining
Areas

Technical requirements for living and
dining areas.

2. The dining area:

11B-806.2.1 Living and Dining
Areas

Technical requirements for living and
dining areas.

3. At least one sleeping
area:

11B-806.2.3 Sleeping Areas

Technical requirements for sleeping
areas.

4. Patios, terraces or
balconies:

11B-806.2.2 Exterior Spaces

Technical requirements for exterior space
including patios, terraces and balconies.

5. Where full bathrooms are
provided, at least . . .

11B-806.2.4 Toilet and Bathing
Facilitates

Technical requirements for toilet and
bathing facilities part of a guest room.

6. Where only half baths are
provided, at . . .

11B-806.2.4 Toilet and Bathing
Facilitates

Technical requirements for toilet and
bathing facilities part of a guest room.

7. Carports, Garages, or
Parking Spaces

11B-208 Parking

Scoping for parking.

• 11B-206.4 Entrances

Scoping for accessible entrances.

• 11B-806.2 Guest Rooms with
Mobility Features

Technical requirement for accessible
feature.

1111B.4.2.3 Doors.

N/A

Title only in 2010 CBC.

1111B.4.2.3.1 Doors into and
within covered rooms and suites.

• 11B-206.4 Entrances

Scoping for accessible entrances.

1111B.4.2.2 Accessible route.

• 11B-206.5 Doors, Doorways
and Gates.
1111B.4.2.3.2 Doors into and
within all other rooms and suites.

• 11B-224.1.2 Guest Room
Doors and Doorways

Scoping for door and doorways in guest
rooms not required to have mobility
features.

• 11B206.5.3 Transient Lodging
Facilities
1111B.4.2.4 Alterations in
existing facilities.

11B-224.1.1 Alterations

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1111B Accessibility for Group R Occupancies

Scoping for alterations.

Page 30 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1111B.4.3 Access to beds.

• 11B-224.3 Beds

Scoping requirements for access to beds.

• 11B-806.2.3 Sleeping Areas

Technical requirements for access to
beds.

• 11B-806.2.3.1 Personal Lift
Device Floor Space

Technical requirements for personal lift
device floor space.

• 11B-212 Kitchens,
Kitchenettes and Wet Bars.

Scoping for kitchens, kitchenettes and wet
bars.

• 11B-806.2.5 Kitchens,
Kitchenettes and Wet Bars.

Technical requirements for kitchens,
kitchenettes and wet bars.

1111B.4.5 Visible alarms,
notification devices and
telephones for persons with
hearing impairments.

• 11B224.4 Guest Rooms with
Communication Features

Scoping requirements for visible alarms,
notification devices and telephones.

• 11B-806.3 Guest Rooms with
Communication Features

Technical requirements for visible alarms,
notification devices and telephones.

1111B.4.5.1 Visible alarms.

11B-806.3.1 Alarms.

Technical requirements for alarms.

1111B.4.5.2 Visual notification
devices.

11B-806.3.2 Notification
Devices

Technical requirements for notification
devices.

1111B.4.5.3 Telephones.

11B-806.3.2 Notification
Devices

Technical requirements for notification
devices including telephones.

1111B.4.6 Bathrooms in hotels,
motels, inns, dormitories,
resorts, homeless shelters,
halfway houses, transient
group homes and similar places
of transient lodging.

11B-806.2.4.

Technical requirements for toilet and
bathing facilities.

1. Doors.

11B-603.2.3 Door Swing

Technical requirements for door swing
into toilet room.

2. Clear floor space.

11B-603.2.1 Turning Space

Technical Requirements for turning space
within the toilet and bathing facility.

3. Water closets.

11B-604.3 Clearance

Technical requirements for clearance
around water closets.

4. Lavatory and mirrors.

• 11B-606 Lavatories and Sinks

Technical requirements for lavatories and
sinks.

• 11B-603.3 Mirrors

Technical requirements for mirrors.

• 11B-309 Operable Parts

Technical requirements for operable parts

• 11B-603.5 Accessories

Technical requirements for accessories

1111B.4.4 Kitchens, kitchenettes
or wet bar facilities.

5. Controls and dispensers.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1111B Accessibility for Group R Occupancies

Page 31 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

6. Bathing and shower
facilities.

• 11B-607 Bathtubs
• 11B-608 Shower
Compartments
• 11B-806.2.4 Toilet and
Bathing Facilities

Technical requirements for bathtubs and
shower compartments

7. Toilet facilities.

• 11B-603 Toilet and Bathing
Rooms
• 11B-604 Water Closets and
Toilet Compartments
• 11B-806.2.4 Toilet and
Bathing Facilities

Technical requirements for toilet rooms

Hotel and motel bathrooms
beyond those specified in
Section 1111B.4 shall
provide the following
features:
1. All bathroom fixtures shall
be in a location that allows a
person using a wheelchair
measuring 30 inches by 48
inches (762 mm by 1219
mm) to touch the wheelchair
to any lavatory, urinal, water
closet, tub, sauna, shower
stall and any other similar
sanitary installation, if
provided.

• 11B-224.1.6 Guest Room
Toilet and Bathing Rooms

Scoping for toilet and bathing rooms in
guest rooms not required to provide
mobility features.

• 11B-603.6 Guest Room Toilet
and Bathing Rooms

Technical requirements for toilet and
bathing rooms in guest rooms not
required to provide mobility features.

2. All bathroom entrance
doors shall have a clear
opening width of 32 inches
(813 mm) and shall be either
sliding doors or shall be
hung to swing in the
direction of egress from the
bathroom.

11B-224.1.2 Guest Room Doors
and Doorways

Technical requirements for clear width at
door for guest rooms not required to have
mobility features.

• 11B-213.2 Toilet Rooms and
Bathing Rooms

1111B.4.7 Storage areas.

11B-224.6 Storage

Scoping for fixed or built-in storage

1111B.4.8 Dormitory rooms.

11B-224.1.2 Guest Room Doors
and Doorways

Technical requirements for clear width at
door for guest rooms not required to have
mobility features. Adaptable feature
language not carried forward, those
features are in kitchens and bathrooms,
not located in dorm room.

1111B.5 Buildings and
complexes containing publicly
funded dwelling units.

N/A

Title only in 2010 CBC

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1111B Accessibility for Group R Occupancies

Page 32 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1111B.5.1 General.

• 11B-233 Residential Facilities

Scoping for publicly funded facilities
containing residential dwelling units

• 11B-233.3.4 Alterations

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1111B Accessibility for Group R Occupancies

Page 33 of 106
5 February 2013

Section 1112B Reserved
Section 1113B Reserved

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1112B & Section 1113B Reserved

Page 34 of 106
5 February 2013

Section 1114B Facility Accessibility
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1114B.1 Design and
construction.

11B-201.1 Scope

General scoping for building and facility
accessibility

1114B.1.1 General.

11B-201.1 Scope

General scoping for building and facility
accessibility

Chapter 11B, Accessibility

11B-201.1 Scope

General scoping for building and facility
accessibility

Entrances

11B-206.4 Entrances

General scoping for building and facility
accessibility

Doors

11B-206.5 Doors, Doorways
and Gates

General scoping for building and facility
accessibility

Corridors

11B-206 Accessible Routes

General scoping for building and facility
accessibility

Stairways

11B-210 Stairways

General scoping for building and facility
accessibility

Ramps

11B-206 Accessible Routes

General scoping for building and facility
accessibility

Aisles

11B-206 Accessible Routes

General scoping for building and facility
accessibility

Walks and Sidewalks

11B-206 Accessible Routes

General scoping for building and facility
accessibility

Hazards

11B-206 Accessible Routes

General scoping for building and facility
accessibility

Elevators

11B-206.6 Elevators

General scoping for building and facility
accessibility

Platform (Wheelchair) Lifts

11B-206.7 Platform Lifts

General scoping for building and facility
accessibility

Alarms

11B-215 Fire Alarm Systems

General scoping for building and facility
accessibility

Bathing and Toilet Facilities

11B-213 Toilet Facilities and
Bathing Facilities

General scoping for building and facility
accessibility

Signs and Identification

11B-216 Signs

General scoping for building and facility
accessibility

Detectable Warnings

11B-705 Detectable Warnings

General scoping and technical
requirements for building and facility
accessibility – detectable warning

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1114B Facility Accessibility

Page 35 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

• 11B-205 Operable Parts
• 11B-211 Drinking Fountains
• 11B-212 Kitchens,
Kitchenettes and Sinks
• 11B-217 Telephones
• 11B-220 Automatic Teller
Machines and Fare Machines
• 11B-222 Dressing, Fitting and
Locker Rooms

General scoping for building and facility
accessibility

• 11B-206 Accessible Routes
• 11B-402 Accessible Routes

Scoping and technical requirements for
accessible routes

11B-206.6 Elevators

Scoping for elevators – where more than
one elevator is provided, all elevators
shall be accessible

1114B.1.3 Primary entry access.

• 11B-206.4 Entrances
• 11B-206.5.5 Exterior Ground
Floor Exit Doors

Scoping for entrances and exterior ground
floor exit doors

1114B.1.4 Signs.

11B-216 Signs

Scoping for signs

1114B.1.5 Adaptable dwelling
units.

11B-206.4.6 Residential
Dwelling Unit Primary
Entrance

Scoping for primary entrances at
residential dwelling units

1114B.2 Egress and areas of
refuge.

11B-207 Accessible Means of
Egress

Scoping for accessible means of egress

1114B.2.1 General.

11B-207 Accessible Means of
Egress

Scoping for accessible means of egress –
reference to Chapter 10, Section 1007

1114B.2.2 Alarms/emergency
warning systems/accessibility.

11B-215 Fire Alarm Systems

Scoping for fire alarm systems –
subsection references to Chapter 9,
Sections 907.5.2.1 and 907.5.2.3

2010 CBC Chapter 11B

Other Building Components

1114B.1.2 Accessible route of
travel.
Exception: Where an
elevator is provided . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1114B Facility Accessibility

Page 36 of 106
5 February 2013

Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1115B.1 General.

• 11B-213.2 Toilet Rooms and
Bathing Rooms
• 11B-603.2 Clearances

General scoping and clearance
requirements for toilet and bathing
facilities

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1115B.1.1 Separate and unisex
facilities.

11B-213.2 Toilet Rooms and
Bathing Rooms

General scoping for toilet and bathing
facilities

1115B.1.2 Where used by
children.

11B-604.9 Water Closets and
Toilet Compartments for
Children’s Use

General scoping for toilet and bathing
facilities used by children

1115B.2 Bathing and shower
facilities.

11B-213.3.6 Bathing
Facilities

General scoping for bathing facilities

1115B.3 Toilet facilities.

11B-604.1 General

Technical requirements for toilet facilities

1115B.3.1 Multipleaccommodation toilet facilities.

11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for multiple-accommodation toilet
facilities

1. Wheelchair clearance.

11B-603.2 Clearances

Technical requirements for turning space

2. Clear floor space at
fixtures.

11B-603.2 Clearances

Technical requirements for overlap and
door swing

3. Accessible fixtures.

• 11B-213.3.2 Water Closets
• 11B-213.3.4 Lavatories

Scoping for water closets and lavatories

4. Accessible water closet
compartment.

11B-604.8.1 Toilet
Compartments

Technical requirements for accessible
compartment within multipleaccommodation toilet facilities

4.1. The compartment
shall be . . . 60 inches
wide.

11B-604.8.1.1 Size

Technical requirement for width of
compartment

4.2. If the compartment
has a side-opening door
...

• 11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door
• 11B-604.8.1.1.2 Maneuvering
Space with Side-Opening
Door

Technical requirement for maneuvering
space in front of water closet in a
compartment with a side-opening door

Exception: In existing
buildings and facilities . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 37 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

4.3. If the compartment
has an end-opening
door . . .

• 11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door
• 11B-604.8.1.1.3 Maneuvering
Space with End-Opening
Door

Technical requirement for maneuvering
space in front of water closet in a
compartment with an end-opening door

4.4. The water closet
compartment shall . . .

11B-604.8.1.2 Doors

Technical requirements for doors

11B-604.8.1.2 Exception

Model code amended to add technical
requirement for 34” clear at in-swinging
side-opening doors

11B-604.8.1.2 Doors

Technical requirements for doors

5. Large toilet rooms.

• 11B-213.3.1 Toilet
Compartments
• 11B-604.8.2 Ambulatory
Accessible Compartments

Scoping and technical requirements for
ambulatory accessible compartments
within multiple-accommodation toilet
facilities

6. Interior surfaces.

11B-302 Floor or Ground
Surfaces

Technical requirement for floors within
toilet facilities

11B-213.2 Toilet Rooms and
Bathing Rooms

Scoping for single-accommodation toilet
facilities

1. Wheelchair clearance.

11B-603.2 Clearances

Technical requirements for turning space

2. Clear floor space at
fixtures.

11B-603.2 Clearances

Technical requirements for overlap and
door swing

3. Accessible water closet.

• 11B-213.3.2 Water Closets
• 11B-604.3.1 Size

Scoping and technical requirements for
water closets

4. Accessible route.

• 11B-213.2 Toilet Rooms and
Bathing Rooms
• 11B-603.2 Clearances

Scoping and technical requirement for
accessible route

5. Interior surfaces.

11B-302 Floor or Ground
Surfaces

Technical requirement for floors within
toilet facilities

6. Accessible lavatory.

11B-213.3.4 Lavatories

Scoping requirement for lavatory

11B-213.2.1 Unisex (Single-Use
or Family) Toilet and Unisex
Bathing Rooms

Scoping requirement for privacy latch

7. Privacy latch.

2010 CBC Chapter 11B

4.5.The inside and
outside of the
compartment door . . .

1115B.3.2 Singleaccommodation toilet facilities.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 38 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1115B.4 Accessible fixtures.

11B-213.3 Plumbing Fixtures
and Accessories

General scoping for accessible toilet and
bathing facilities fixtures

1115B.4.1 Accessible water
closets.

11B-213.3.2 Water Closets

General scoping for water closets

1. The centerline of the
water closet . . .

• 11B-604.2 Location
• 11B-604.3 Clearance

Technical requirements for centerline and
clearances at water closets

2. Provide clear floor
space . . .

11B-604.3 Clearance

Technical requirements for clearances at
water closets

2.1. Where a water
closet is not within a
water closet
compartment . . .

11B-604.3.1 Size

Technical requirements for size of
clearance at water closets not located
within accessible compartments

2.2. Where a wall
mounted water closet is
installed within . . .

11B-604.8.1.1 Size

Technical requirements for size of
clearance at water closets located within
accessible compartments

2.3. Where a water
closet is installed within
an accessible . . .

11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door

Technical requirements for maneuvering
space at compartments with in-swinging
doors

11B-604.3.2 Overlap Exception

Exception for adjacent fixture at the rear
wall applicable in residential dwelling units
only

• 11B-604.5 Grab Bars
• 11B-604.8.1.5 Grab Bars
• 11B-604.8.2.3 Grab Bars

Scoping for grab bars in accessible
compartments and ambulatory accessible
compartments.

3.1. Side wall

11B-604.5.1 Side Wall

Technical requirements for side wall grab
bars

3.2. Rear wall

11B-604.5.2 Rear Wall

Technical requirements for rear wall grab
bars

11B-604.4 Seats

Technical requirements for toilet seats

11B-604.4 Exception

Exception permitted only in alterations

2010 CBC Chapter 11B

Exception: In an existing
building, a singleaccommodation toilet
facility . . .

Exception: An
adjacent fixture at
the rear wall . . .
3. Grab bars for . . .

4. The height of accessible
water closets . . .
Exception: A 3-inch high
seat . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 39 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

5. Controls shall be
operable . . .

11B-604.6 Flush Controls

Technical requirements for flush controls

6. See Section 1134A.7 for
additional requirements . . .

N/A

Requirements for residential dwelling
units located in 2013 CBC, Chapter 11B

7. Automatic springs to lifted
position . . .

N/A

Not addressed by 2010 ADAS

11B-213.3.3 Urinals

General scoping for urinals

1. Urinals shall be . . .

11B-605.2 Height and Depth

Technical requirements for urinal height
and depth

2. Flush controls . . .

11B-605.4 Flush Controls

Technical requirements for flush controls
at urinals

3. Where urinals are
provided . . .

11B-605.3 Clear Floor Space

Technical requirement for clear floor
space at urinals

11B-213.3.4 Lavatories

General scoping for lavatories

1. Faucet controls and . . .

11B-606.4 Faucets

Technical requirements for controls for
faucets

2. Lavatories, when located
adjacent to . . .

• 11B-606.2 Clear Floor Space
• 11B-606.3 Height
• 11B-606.6 Adjacent Side Wall
or Partition

Technical requirements for height,
location and toe and knee clearance

3. A clear floor space 30
inches . . .

• 11B-306 Knee and Toe
Clearance
• 11B-606.2 Clear Floor Space

Technical requirements for toe and knee
clearance and clear floor space

4. Hot water and drain pipes
...

11B-606.5 Exposed Pipes and
Surfaces

Technical requirements for exposed pipes
and surfaces beneath lavatories

1115B.4.4 Accessible showers.

11B-213.3.6 Bathing Facilities

General scoping for showers

1115B.4.4.1 Size and
clearances.

11B-608.2 Size and Clearances
for Shower Compartments

General scoping for shower
compartments

1. Roll-in shower . . .

11B-608.2.2 Standard Roll-In
Type Shower Compartment

Technical requirements for standard rollin type shower compartments

2. Alternate roll-in shower 60
inches minimum in width . . .

11B-608.2.3 Alternate Roll-In
Type Shower Compartment

Technical requirements for alternate rollin type shower compartments

3. Alternate roll-in shower
with optional enclosure . . .

• 11B-608.2.3 Alternate Roll-In
Type Shower Compartment
• 11B-608.8 Shower
Enclosures

Technical requirements for alternate rollin type shower compartments applicable

2010 CBC Chapter 11B

1115B.4.2 Accessible urinals.

1115B.4.3 Accessible lavatories.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 40 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1115B.4.4.2 Thresholds.

11B-608.7 Thresholds

Technical requirements for thresholds

1115B.4.4.3 Orientation.

11B-213.3.6 Bathing Facilities

Scoping requirement for orientation

1115B.4.4.4 Water controls.

11B-608.5 Controls

Technical requirements for controls

1. Controls in a . . . roll-in
shower . . .

11B-608.5.2 Standard Roll-In
Type Shower Compartments

Technical requirements for controls in
standard roll-in type shower
compartments

2. Controls in an . . .
alternate roll-in shower . . .

11B-608.5.3 Alternate Roll-In
Type Shower Compartments

Technical requirements for controls in
alternate roll-in type shower
compartments

3. Controls in an . . .
alternate roll-in shower . . .
with optional enclosure . . .

11B-608.5.3 Alternate Roll-In
Type Shower Compartments

Technical requirements for controls in
alternate roll-in type shower
compartments applicable

1115B.4.4.5 Hand-held sprayer
unit.

11B-608.6 Shower Spray Unit
and Water

1. The hand-held sprayer
unit . . .

11B-608.5.2 Standard Roll-In
Type Shower Compartments

Technical requirements for shower sprays
in standard roll-in type shower
compartments

2. The hand-held sprayer
unit . . . in an . . . alternate
roll-in shower . . .

11B-608.5.3 Alternate Roll-In
Type Shower Compartments

Technical requirements for shower sprays
in alternate roll-in type shower
compartments

3. The hand-held sprayer
unit . . . in an . . . alternate
roll-in shower . . . with
optional enclosure . . .

11B-608.5.3 Alternate Roll-In
Type Shower Compartments

Technical requirements for shower sprays
in alternate roll-in type shower
compartments applicable

1115B.4.4.6 Sprayer unit
alternative.

11B-608.6 Exception

Exception permitted in areas subject to
excessive vandalism only

1115B.4.4.7 Floor slope.

11B-608.9 Shower Floor or
Ground Surface

Technical requirements for shower floor
surface

1115B.4.4.8 Shower
accessories.

11B-608.1 General

General scoping for showers

1. A folding seat . . .

• 11B-608.4 Seats
• 11B-610.3 Shower
Compartment Seats

Technical requirements for seats

2. Grab bars located on
walls . . .

11B-608.3 Grab Bars

Technical requirements for grab bars

1115B.4.4.9 Soap dish.

11B-608.10 Soap Dish

Technical requirements for soap dishes

1115B.4.4.10 Enclosures.

11B-608.8 Shower Enclosures

Technical requirements of enclosures

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 41 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1115B.4.5 Accessible bathtubs.

11B-213.3.6 Bathing Facilities

General scoping for bathtubs

1. Floor space.

11B-607.2 Clearance

Technical requirements for clearances at
bathtubs

2. Seat.

• 11B-607.3 Seat
• 11B-610.2 Bathtub Seats

Technical requirements for seats

3. Grab bars.

11B-607.4 Grab Bars

Technical requirements for grab bars

4. Controls.

11B-607.5 Controls

Technical requirements for controls

5. Shower unit.

11B-607.6 Shower Spray Unit
and Water

Technical requirements for shower spray
units.

6. Bathtub enclosures.

11B-607.7 Bathtub Enclosures

Technical requirements for enclosures

1115B.5 Passageways.

• 11B-603.2.3 Door Swing
• 11B-604.8.1.2 Doors

Technical requirements for doors and
door swings

1115B.6 Identification symbols.

• 11B-216.8 Toilet Rooms and
Bathing Rooms
• 11B-703.7.2.6 Toilet and
Bathing Facilities Geometric
Symbols

Scoping and technical requirements for
geometric identification symbols at toilet
and bathing rooms

1115B.6.1 Men’s sanitary
facilities . . .

11B-703.7.2.6.1 Men’s Toilet
and Bathing Facilities

Technical requirements for geometric
identification symbols

1115B.6.2 Woman’s sanitary
facilities . . .

11B-703.7.2.6.2 Women’s Toilet
and Bathing Facilities

Technical requirements for geometric
identification symbols

1115B.6.3 Unisex sanitary
facilities . . .

11B-703.7.2.6.3 Unisex Toilet
and Bathing Facilities

Technical requirements for geometric
identification symbols

1115B.7 Grab bars, tub and
shower seats.

• 11B-609.1 General
• 11B-610.1 General

General scoping for grab bars & seats

1115B.7.1 Diameter or width.

• 11B-609.2 Cross Section
• 11B-609.3 Spacing

Technical requirements for grab bar size
and mounting distance from wall

1115B.7.2 Structural strength.

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

1. Bending stress . . .

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

2. Shear stress . . .

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 42 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

3. Shear force induced . . .

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

4. Tensile force induced . . .

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

5. Grab bars shall not rotate
within their fittings.

• 11B-609.8 Structural Strength
• 11B-610.4 Structural Strength

Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures

1115B.7.3 Surface.

11B-609.5 Surface Hazards

Technical requirements for the surface of
grab bars

1115B.8 Accessories.

11B-603.5 Accessories

Technical requirements for accessories

1115B.8.1 Mirrors.

11B-213.3.5 Mirrors

Scoping for mirrors in toilet and bathing
facilities

1115B.8.1.1. All mirrors located
above accessible lavatories . . .

11B-603.3 Mirrors

Technical requirements for mirrors

1115B.8.1.2. When mirrors are
provided other than above
lavatories . . .

11B-603.3 Mirrors

Technical requirements for mirrors

1115B.8.1.3

11B-222.3 Mirrors

General scoping for mirrors in fitting and
dressing rooms

1115B.8.2 Medicine cabinets.

• 11B-225.2 Storage
• 11B-603.4 Coat Hooks,
Shelves and Medicine
Cabinets

General scoping and technical
requirement for coat hooks, shelves and
medicine cabinets

1115B.8.3 Towel, sanitary
napkins, waste receptacles,
dispensers and controls.

11B-603.5 Accessories

Technical requirements for accessories

1115B.8.4 Toilet tissue
dispensers.

11B-604.7 Dispensers

Technical requirements for toilet paper
dispensers

1115B.8.5 Lockers.

• 11B-225.2.1 Lockers
• 11B-811 Storage

General scoping and technical
requirements for lockers

2010 CBC Chapter 11B

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)

Page 43 of 106
5 February 2013

Section 1116B Elevators and Platform (Wheelchair) Lifts
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1116B.1 Elevators.

• 11B-206.6 Elevators

Chapter 35 Referenced Standards
ASME A17.1
Scoping for Elevators

• 11B-407.1 General
• 11B-407.1.1 Combined
Passenger and Freight
Elevators

Technical requirements for combined
passenger and freight elevators.

N/A

Title only in 2010 CBC.

Exception 1. In existing
buildings . . .

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2. In existing
buildings . . . the minimum
car plan dimension . . .

11B-407.4.1 Car Dimensions.
Exception.

In existing buildings, where existing shaft
configuration or technical infeasibility
prohibits strict compliance with 11B407.4.1, existing elevator car
configurations that provide a clear floor
2
area of 18 square feet (1.67 m )
minimum and also provide an inside clear
depth 54 inches (1372 mm) minimum and
a clear width 48 inches (1219 mm)
minimum shall be permitted.

Exception 3. In existing
buildings equivalent
facilitation . . .

11B-103 Equivalent Facilitation

General provision for equivalent
facilitation is available; no need for
specific exception.

Exception 4. These
provisions shall not apply . . .

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

• 11B-407.1 General.
• 11B-407.4.3 Platform to
Hoistway Clearance.
• 11B-407.4.4 Leveling.

Technical requirements for automatic
operation, clearance and leveling.

1116B.1.1 General.

1116B.1.2 Operation and
leveling.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1116B Elevators and Platform (Wheelchair) Lifts

Page 44 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1116B.1.3 Door operation.

• 11B-407.3.1 Type.
• 11B-407.3.2 Operation.

Technical requirements for door operation

1116B.1.4 Door size.

11B-407.4.1 Elevator Car
Dimensions

Technical requirements for elevator car
and door dimensions

1116B.1.5 Door protective and
reopening device

• 11B-407.3.3 Reopening
Device
• 11B-407.3.3.1 Height
• 11B-407.3.3.2 Contact
• 11B-407.3.3.3 Duration

Technical requirements for reopening
device.

1116B.1.6 Hall call.

11B-407.3.4 Door and Signal
Timing

Technical requirements for door and
signal timing.

1116B.1.7 Car

11B-407.3.5 Door Delay

Technical requirement for door delay.

1116B.1.8 Car inside.

• 11B-407.4.1 Car Dimensions.

Technical requirements for elevator car
dimensions.

• 11B-407.4.2 Floor Surfaces.

Technical requirements for floor surfaces.

• 11B-407.4.6.1 Location

Technical requirements for reach range

• 11B-407.4.6.4 Emergency
Controls

Technical requirements for emergency
controls

• 11B-407.4.7.1.4 Visible
Indicators

Technical requirements for visible
indicators.

• 11B-407.4.9 Emergency
Communications

Technical requirements for emergency
communications

• 11B-408.4.6 Location
• 11B-409.4.6.2 Location

Technical requirements for location of
control panels.

• 11B-407.4.6.2 Buttons
• 11B-407.4.6.2.1 Size and
Shape
• 11B-407.4.6.2.3 Illumination
• 11B-407.4.6.2.4 Operation
• 11B-407.4.7.1.1 Type
• 11B-407.4.7.1.2 Location
• 11B-407.4.7.1.3 Symbols
• 11B-407.4.8.1 Visible
Indicators
• 11B-407.4.8.2 Audible
Indicators

Technical requirements for control
buttons.

1116B.1.9 Car controls.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1116B Elevators and Platform (Wheelchair) Lifts

Page 45 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1116B.1.10 Hall call buttons.

• 11B-407.2.1.1 Height
• 11B-407.2.1.2 Size and
Shape
• 11B-407.2.1.3 Clear Floor or
Ground Space
• 11B-407.2.1.4 Location
• 11B-407.4.8.2 Audible
Indicators

Technical requirements for hall call
buttons

1116B.1.11 Handrails.

11B-407.4.10 Support Rail

Technical requirements for support rail.

1116B.1.12 Minimum
illumination.

11B-407.4.5 Illumination

Technical requirements for illumination at
car, threshold and landing.

1116B.1.13 Hall lantern.

• 11B-407.2.2.1 Visible and
Audible Signals
• 11B-407.2.2.2 Visible Signals
• 11B-407.2.2.3 Audible
Signals

Technical requirements for visible and
audible signals.

1116B.1.14 Doorjamb marking.

11B-407.2.3.1 Floor
Designation

Technical requirements for door jamb
markings

1116B.1.15 Location.

• 11B-402.2 Components
• 11B-108 Maintenance of
Accessible Features

Scoping for elevators

1116B.2 Platform (wheelchair)
lifts.

11B-206.7 Platforms Lifts

Scoping for platform lifts

1.

11B-206.7.1 Performance
Areas and Speakers’
Platforms

Scoping for platform lifts

2.

11B-206.7.2 Wheelchair
Spaces

Scoping for platform lifts

3.

11B-206.7.3 Incidental Spaces

Scoping for platform lifts

4.

11B-206.7.5 Existing Site
Constraints

Scoping for platform lifts

Exception

11B-206.7 Platform Lifts

Scoping for platform lifts.

1116B.2.1 General.

11B-410.1 General

Technical requirements for compliance
with ASME A18.1

1116B.2.2 Unassisted entry.

11B-410.1 General

Technical requirements for unassisted
entry

1116B.2.3 Landing size.

11B-410.7 Landing Size

Technical requirements for landing size

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1116B Elevators and Platform (Wheelchair) Lifts

Page 46 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1116B.2.4 Relationship to the
path of travel.

11B-402.2 Components

Location on accessible route

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1116B.2.5 When provided as a
means of egress.

11B-207.1 General

Scoping for platform lifts as a means of
egress.

1116B.2.5.1 Standby power.

11B-207.2 Platforms Lifts

Scoping for standby power at platform
lifts.

1116B.2.5.2

11B-206.7.2 Wheelchair
Spaces

Scoping for platform lifts, used to comply
with line-of-sight and dispersion
requirements.

1116B.2.6 Doors and gates.

11B-410.6 Doors and Gates

Technical requirements for doors and
gates at platform lifts.

11B-410.6 Doors and Gates,
Exception

Technical requirements for doors and
gates at platform lifts.

11B-410.8 Restriction Sign

Technical requirements for restriction
sign.

Exception

1116B.2.7 Restriction sign.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1116B Elevators and Platform (Wheelchair) Lifts

Page 47 of 106
5 February 2013

Section 1117B Other Building Components
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1117B.1 Accessible drinking
fountains.
1. General.

11B-211.1 General

General scoping for drinking fountains.

• 11B-211.2 Minimum Number
• 11B-211.3 More Than
Minimum Number

General scoping for drinking fountains.

2. Clearances.

• 11B-306 Knee and Toe
Clearance
• 11B-602.2 Clear Floor Space
• 11B-602.8 Depth

Technical requirements for clear floor
space, knee and toe clearance, and
depth.

3. Alcoves.

11B-602.9 Pedestrian
Protection

Technical requirements for pedestrian
protection – alcoves or wing walls.

4.

• 11B-602.4 Spout Height
• 11B-602.5 Spout Location

Technical requirements for spout location
and height.

5.

11B-602.6 Water Flow

Technical requirement for water flow.

1117B.2 Telephones.

11B-217.1 General

General scoping for public telephones

1117B.2.1 General.

11B-217.2 Wheelchair
Accessible Telephones

General scoping for wheelchair
accessible telephones

1117B.2.2 Clear floor or ground
space.

11B-704.2.1 Clear Floor or
Ground Space

Technical requirements for clear floor or
ground space

1117B.2.3 Size and approach.

• 11B-704.2.1.1 Parallel
Approach
• 11B-704.2.1.2 Forward
Approach

Technical requirements for parallel or
forward approach

1117B.2.4 Relationship of
maneuvering clearances to
wheelchair spaces.

• 11B-704.2.1 Clear Floor or
Ground Space
• 11B-305.6 Approach

Technical requirements for clear floor
space and approach

1117B.2.5 Floor surfaces of
wheelchair spaces.

• 11B-704.2.1 Clear Floor or
Ground Space
• 11B-302.1 General

Technical requirements for floor surfaces

1117B.2.6 Mounting height.

• 11B-704.2.2. Operable Parts
• 11B-309 Operable Parts

Technical requirements for mounting
height of operable parts

1117B.2.7 Enclosures.

11B-704.2.1 Clear Floor or
Ground Space

Technical requirements for clear floor
space at an enclosure

1. Side reach possible.

11B-704.2.1.1 Parallel
Approach

Technical requirements for parallel
approach at a telephone within an
enclosure

2. Full-height enclosures.

11B-704.2.1.2 Forward
Approach

Technical requirements for forward
approach at a telephone within an
enclosure

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 48 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

3. Forward reach required.

11B-704.2.1.2 Forward
Approach

Technical requirements for forward
approach at a telephone within an
enclosure

4. Protruding telephone
enclosures.

11B-307 Protruding Objects

Technical requirements for protruding
objects

1117B.2.8 Telephone equipment
for hearing impaired persons.

11B-704.3 Volume Control
Telephones

Technical requirements for public
telephones required to have volume
controls

1117B.2.9 Text telephones.

11B-217.4 TTYs

General scoping for TTYs

1117B.2.9.1 Where required.

• 11B-217.4.1 Bank
Requirement
• 11B-217.4.2 Floor
Requirement

General scoping for the number of TTYs
required in specific locations

1.

• 11B-217.4.1 Bank
Requirement
• 11B-217.4.2 Floor
Requirement

General scoping for the number of TTYs
required in specific locations

2.

• 11B-217.4.3.1 Public
Buildings
• 11B-217.4.4 Exterior Site
Requirements

General scoping for the number of TTYs
required in specific locations

3.

11B-217.4.6 Hospitals

General scoping for the number of TTYs
required in specific locations

4.

• 11B-217.4.3.2 Private
Buildings
• 11B-217.4.4 Exterior Site
Requirements

General scoping for the number of TTYs
required in specific locations

5.

• 11B-217.4.3.2 Private
Buildings
• 11B-217.4.4 Exterior Site
Requirements

General scoping for the number of TTYs
required in specific locations

11B-704.4 TTYs

Technical requirements for TTYs

1.

11B-704.4 TTYs

Technical requirements for TTYs

2.

• 11B-217.5 Shelves for
Portable TTYs
• 11B-704.5 TTY Shelf

Scoping for shelves for portable TTYs

3.

11B-103 Equivalent Facilitation

General provision for the use of products
providing equivalent facilitation

1117B.2.9.3 Signage.

11B-219 TTYs

Scoping for signs required for TTYs

1117B.2.10 Controls.

11B-704.2.2 Operable Parts

Technical requirements for operable parts

2010 CBC Chapter 11B

1117B.2.9.2 General.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 49 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1117B.2.11 Cord length.

11B-704.2.4 Cord Length

Technical requirements for cord length

1117B.2.12 Telephone books.

11B-704.2.3 Telephone
Directories

Technical requirements for telephone
directories

1117B.3 Kitchens.

• 11B-233 Residential
Facilities
• 11B-804 Kitchens &
Kitchenettes

Scoping for Residential Facilities

• 11B-242 Swimming Pools,
Wading Pools, and Spas

Scoping for swimming pools, wading
pools, and spas.

• 11B-1009 Swimming Pools,
Wading Pools, and Spas

Technical requirements for swimming
pools, wading pools, and spas.

1117B.5 Signs and identification.

• 11B-703 Signs

Obsolete advisory reference to Section
4.30 of the 1991 Standards not carried
forward

1117B.5.1 General.

• 11B-216.1 General
• 11B-703.1 General

General scoping and technical
requirements for signs

1. Identification signs.

• 11B-216.2 Designations
• 11B-703.2 Raised Characters
• 11B-703.3 Braille

Scoping and technical requirements for
interior and exterior signs identifying
permanent room and spaces

2. Directional and
informational signs.

• 11B-216.3 Directional and
Informational Signs
• 11B-703.5 Visual Characters

Scoping and technical requirements for
signs that provide directions to or
information about facilities

3. Accessibility signs.

11B-703.7 Symbols of
Accessibility

Scoping and technical requirements for
symbols of accessibility

11B-703.1.1 Plan Review and
Inspection

Plan review and inspection requirements

4.1. Plan review.

11B-703.1.1.1 Plan Review

Plan review and inspection requirements

4.2. Inspection.

11B-703.1.1.2 Inspection

Plan review and inspection requirements

4.3. Other signs and
identification.

11B-703.1.1 Plan Review and
Inspection

Plan review and inspection requirements

1117B.5.2 Finish and contrast.

• 11B-703.5.1 Finish and
Contrast
• 11B-703.6.2 Finish and
Contrast
• 11B-703.7.1 Finish and
Contrast

Technical requirements for non-glare
finish on visual signs, including
pictograms and symbols of accessibility

1117B.5.3 Proportions.

• 11B-703.2.4 Character
Proportions
• 11B-703.2.6 Stroke Thickness

Technical requirements for characters on
tactile signs

1117B.4 Swimming pools.

4. Plan review and inspection.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Technical requirements for kitchens &
kitchenettes

Page 50 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1117B.5.4 Character height.

• 11B-703.5.4 Character
proportions
• 11B-703.5.5 Character Height

Technical requirements for characters on
visual signs

1117B.5.5 Raised characters
and pictorial symbol signs.

• 11B-703.2 Raised Characters
• 11B-703.6 Pictograms

Technical requirements for raised
characters and pictograms

1. Character type.

• 11B-703.2.1 Depth
• 11B-703.2.2 Case
• 11B-703.2.3 Style

Technical requirements for depth, case &
style of raised characters

2. Character size.

11B-703.2.5 Character Height

Technical requirements for height of
raised characters

3. Pictorial symbol signs
(pictograms).

• 11B-703.6.1 Pictogram Field
• 11B-703.6.3 Text Descriptors

Technical requirements for pictograms

4. Character placement.

• 11B-703.2.9 Format
• 11B-703.3.2 Position

Technical requirements for horizontal
format and Braille position

1117B.5.6 Braille.

• 11B-703.3 Braille
• 11B-703.3.1 Dimensions and
Capitalization

Technical requirements for Braille

1117B.5.7 Mounting location and
height.

• 11B-703.4.1 Height Above
Finish Floor or Ground
• 11B-703.4.2 Location

Technical requirements for mounting
location and height

1117B.5.8 Symbols of
accessibility.

11B-703.7.2 Symbols

Technical requirements for symbols of
accessibility

1117B.5.8.1 International
Symbol of Accessibility.

11B-703.7.2.1 International
Symbol of Accessibility

Technical requirements for International
Symbol of Accessibility

Exception
1117B.5.8.1.1 Color of symbol.

N/A
11B-703.7.2.1 International
Symbol of Accessibility

Technical requirements for International
Symbol of Accessibility

11B-703.7.2.1 Exception

Technical requirements for International
Symbol of Accessibility

11B-216.6 Entrances

Scoping for sign requirements at entrance
doors

Exception 1

11B-216.6 Entrances,
Exception 1

Scoping for sign requirements at entrance
doors

Exception 2

11B-216.6 Entrances,
Exception 2

Scoping for sign requirements at entrance
doors

11B-216.7 Elevators
11B-216.8 Toilet Rooms and
Bathing Rooms

Scoping for signs providing information
about specific accessible elements

Exception

1117B.5.8.1.2 Entrance signs.

1117B.5.8.1.3 Information
posted.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 51 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1117B.5.8.2 International TTY
symbol.

• 11B-216.9 TTYs
• 11B-703.7.2.2 International
Symbol of TTY

Scoping and technical requirements for
International Symbol of TTY

1117B.5.8.3 Volume control
telephones.

11B-703.7.2.3 Volume Control
Telephones

Scoping and technical requirements for
volume control telephones

1117B.5.8.4 Assistive listening
systems.

• 11B-216.10 Assistive
Listening Systems
• 11B-703.7.2.4 Assistive
Listening Systems

Scoping and technical requirements for
assistive listening systems

1117B.5.9 Traffic-control
devices.

11B-703.7.2.7 Pedestrian
Traffic-Control Buttons

Scoping and technical requirements for
pedestrian traffic-control buttons

1117B.5.10 Signs for text
telephones.

N/A

Reference to “TDD” designation not
carried forward.

1117B.5.11 Cleaner air symbol.

• 11B-216.13.1 Cleaner Air
Symbol
• 11B-703.7.2.5 Cleaner Air
Symbol

Scoping and technical requirements for
cleaner air symbol

1117B.5.11.1 Color and size of
symbol.

11B-703.7.2.5 Cleaner Air
Symbol

Technical requirements for cleaner air
symbol

1117B.5.11.2 Conditions of use.

11B-216.13.1 Use of Cleaner
Air Symbol

Scoping for use of cleaner air symbol

1117B.5.11.3 Removal of
symbol.

11B-216.13.2 Removal of
Cleaner Air Symbol

Scoping for removal of cleaner air symbol

1117B.6 Controls and operating
mechanisms.

11B-205 Operable Parts

General scoping for operable parts

1. General.

• 11B-205.1 General
• 11B-309.1 General

General scoping for operable parts

2. Clear floor space.

11B-309.2 Clear Floor Space

Technical requirements for clear floor
space

3. Height.

11B-309.3 Height

Technical requirements for height

11B-205.1 General, Exceptions

General scoping for operable parts

4. Operation.

11B-309.4 Operation

Technical requirement for operation

5. Installation heights of
electrical switches and
receptacle outlets.

• 11B-308.1.1 Electrical
Switches
• 11B-308.1.2 Electrical
Receptacle Outlets

Technical requirements for electrical
switches and receptacle outlets

11B-308.1.1 Electrical Switches

Technical requirements for electrical
switches

Exception

5.1. Electrical switches.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 52 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

11B-308.1.2 Electrical
Receptacle Outlets

Technical requirements for electrical
receptacle outlets

Exception 1

11B-205.1 General, Exceptions

General scoping for operable parts

Exception 2

11B-205.1 General, Exceptions

General scoping for operable parts

Exception 3

11B-205.1 General, Exceptions

General scoping for operable parts

Exception 4

11B-205.1 General, Exceptions

General scoping for operable parts

1117B.7 Automated teller
machines and point of sale
machines.

11B-220 Automatic Teller
Machines, Fare Machines and
Point-of-Sale Devices

General scoping for automatic teller
machines

1117B.7.1 General.

11B-220.1 Automatic Teller
Machines and Fare Machines

General scoping for automatic teller
machines

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 3

11B-308.3.1, Exception 2

Exception for operable parts of fuel
dispensers

1117B.7.1.1

11B-220.1 Automatic Teller
Machines and Fare Machines

Scoping for automatic teller machines

1117B.7.1.1.1 One ATM.

11B-220.1.1 One Automatic
Teller Machine or Fare
Machine

Scoping for automatic teller machines

1117B.7.1.1.2 Two ATMs

11B-220.1.2 Two Automatic
Teller Machines or Fare
Machines

Scoping for automatic teller machines

1117B.7.1.1.3 Three or more
ATMs

11B-220.1.3 Three or More
Automatic Teller Machines or
Fare Machines

Scoping for automatic teller machines

2010 CBC Chapter 11B

5.2. Electrical receptacle
outlets

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 53 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1117B.7.1.2 Where bins …

11B-220.1 Automatic Teller
Machines and Fare Machines

Scoping for bins for envelopes, waste or
other purposes

1117B.7.1.3 (point-of-sale)

11B-220.2 Point-of-Sale
Devices

Scoping for point-of-sale devices

1117B.7.2 Clear floor or ground
space.

11B-707.2 Clear Floor or
Ground Space

Technical requirements for clear floor
space

11B-707.2 Exception

Exception for drive-up only machines

11B-707.3 Operable Parts

Technical requirements for operable parts

11B-707.3 Exception

Exception for drive-up only machines

1117B.7.3.1 (clear key)

• 11B-707.5 Speech Output
• 11B-707.6.1 Input Controls
• 11B-707.6.3.2 Tactile
Symbols

Technical requirements for operable parts
discernible by sound or touch

1117B.7.4 Privacy.

11B-707.4 Privacy

Technical requirements for same degree
of privacy of input and output

1117B.7.5 Speech output.

11B-707.5 Speech Output

Technical requirements for speech output

Exception 1

11B-707.5, Exception 1

Technical requirements for speech output

Exception 2

11B-707.5, Exception 2

Technical requirements for speech output

Exception 3

11B-707.5, Exception 3

Technical requirements for speech output

11B-707.5.1 User Control

Technical requirement for user control of
speech function

11B-707.5.1, Exception

Technical requirement for user control of
speech function

11B-707.5.2 Receipts

Technical requirements for receipts

Exception 1

11B-707.5.2, Exception 1

Technical requirements for receipts

Exception 2

11B-707.5.2, Exception 2

Technical requirements for receipts

Exception 3

11B-707.5.2, Exception 3

Technical requirements for receipts

1117B.7.6 Input.

11B-707.6 Input

Technical requirements for input controls

1117B.7.6.1 Input controls.

11B-707.6.1 Input Controls

Technical requirements for input controls

1117B.7.6.2 Numeric keys.

11B-707.6.2 Numeric Keys

Technical requirements for input controls

1117B.7.6.3 Function keys.

11B-707.6.3 Function Keys

Technical requirements for input controls

1117B.7.6.3.1 Contrast

11B-707.6.3.1 Contrast

Technical requirements for input controls

Exception
1117B.7.3 Operable parts.
Exception

1117B.7.5.1 User control.

Exception

1117B.7.5.2 Receipts.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 54 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

Exception

11B-707.6.3.1, Exception

Technical requirements for input controls

11B-707.6.3.2 Tactile Symbols
11B-707.7 Display Screen

Technical requirements for input controls
Technical requirements for display
screens

11B-707.7, Exception

Technical requirements for display
screens

1117B.7.7.1 Visibility.

11B-707.7.1 Visibility

Technical requirements for display
screens

1117B.7.7.1.1 Vertically
mounted display screen.

11B-707.7.1.1 Vertically
Mounted Display Screen

Technical requirements for display
screens

1117B.7.7.1.2 Angle-mounted
display screen.

11B-707.7.1.2 Angle Mounted
Display Screen

Technical requirements for display
screens

1117B.7.7.1.3 Horizontally
mounted display screen.

11B-707.7.1.3 Horizontally
Mounted Display Screen

Technical requirements for display
screens

1117B.7.7.2 Characters.

11B-707.7.2 Characters

Technical requirements for characters
displayed on the screen

1117B.7.8 Braille instructions.

11B-707.8 Braille Instructions

Technical requirements for Braille
instructions

1117B.7.9 Point-of-sale devices

• 11B-707.9 Point-of-Sale
Devices
• 11B-707.9.1 General

Technical requirements for point-of-sale
devices

1117B.7.9.1

11B-707.9.1.1 Tactilely
Discernible Numerical Keypad

Technical requirements for point-of-sale
devices

1117B.7.9.2

11B-707.9.1.2 Other
Technology

Technical requirements for point-of-sale
devices

1117B.8 Fitting and dressing
rooms.

• 11B-222 Dressing, Fitting and
Locker Rooms
• 11B-803 Dressing, Fitting and
Locker Rooms
• 11B-903 Benches

Scoping and technical requirements for
dressing and fitting rooms, including clear
space, benches, coat hooks and mirrors

1117B.9 Accessible sinks.

• 11B-212.3 Sinks

General scoping for sinks

1.

11B-606.2 Clear Floor Space

Technical requirements for clear floor
space

2.

• 11B-606.3 Height
• 11B-606.2 Clear Floor Space
• 11B-606.5 Exposed Pipes
and Surfaces
• 11B-606.7 Sink Depth

Technical requirements for height, knee &
toe clearance, depth and exposed pipes

3.

11B-606.4 Faucets

Technical requirements for control

1117B.7.6.3.2 Tactile symbols.
1117B.7.7 Display screen.

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1117B Other Building Components

Page 55 of 106
5 February 2013

Section 1118B Space Allowance and Reach Ranges
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1118B.1 Wheelchair passage
width.

• 11B-403.5.1 Clear Width
• 11B-403.5.1, Exception 1
• 11B-403.5.2 Clear Width at
Turn

Technical requirements for clear width,
clear width at a point and clear width at
turns around obstructions

1118B.2 Width for wheelchair
passing.

11B-403.5.3 Passing Spaces

Technical requirements for passing
spaces

1118B.3 Wheelchair turning
space.

11B-304.3 Size

Technical requirements for turning space
– circular or T-shaped

1118B.4 Clear floor or ground
space for wheelchairs.

11B-305 Clear Floor or Ground
Space

Technical requirements for clear floor or
ground space

1. Size and approach.

• 11B-305.3 Size
• 11B-305.4 Knee and Toe
Clearance
• 11B-305.5 Position

Technical requirements for clear floor or
ground space – size, knee & toe space,
parallel or forward approach

2. Relationship of
maneuvering clearances to
wheelchair spaces.

• 11B-305.6 Approach
• 11B-305.7 Maneuvering
Clearance

Technical requirements for clear floor or
ground space – accessible route and
maneuvering clearances at alcoves

3. Surfaces for wheelchair
spaces.

11B-305.2 Floor or Ground
Surfaces

Technical requirements for clear floor or
ground space – floor or ground surface

1118B.5 Forward reach.

11B-308.2 Forward Reach

Technical requirements for forward reach

1118B.5.1 Unobstructed.

11B-308.2.1 Unobstructed

Technical requirements for forward reach

1118B.5.2 Obstructed high
reach.

11B-308.2.2 Obstructed High
Reach

Technical requirements for forward reach

1118B.6 Side reach.

11B-308.3 Side Reach

Technical requirements for side reach

1118B.6.1 Unobstructed.

11B-308.3.1 Unobstructed

Technical requirements for side reach

11B-308.3.1, Exception 1

Technical requirements for side reach

11B-308.3.2 Obstructed High
Reach

Technical requirements for side reach

11B-308.3.2, Exception 1

Technical requirements for side reach

Exception
1118B.6.2 Obstructed High
reach.
Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1118B Space Allowance and Reach Ranges

Page 56 of 106
5 February 2013

Section 1119B Special Standards of Accessibility for Buildings with Historical
Significance
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

See Section 1135B

11B-202.5 Alterations to
Qualified Historic Buildings and
Facilities.

Current reference to State Historic
Building Code accessibility provisions is
maintained in 2013 CBC.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1119B Special Standards of Accessibility for Buildings with Historical Significance

Page 57 of 106
5 February 2013

Section 1120B Floor and Levels
2010 CBC Chapter 11B

2013 CBC Chapter 11B

1120B.1 Floors within each
story.

• 11B-206 Accessible Routes
• 11B-302 Floor or Ground
Surfaces

Comments

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 3

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 4

N/A

1120B.2 Floor surface.

11B-302.1 General

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1120B Floors and Levels

Technical requirement for slip resistant
floor surfaces

Page 58 of 106
5 February 2013

Section 1121B Transportation Facilities
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1121B.1 General.

• 11B-810 Transportation
facilities

Technical requirements for transportation
facilities.

• 11B-206 Accessible Route

Scoping for accessible route.

• 11B-206.2.3 Exception 2.2
Elevator requirements

Scoping for elevators.

1121B.2 Bus stops and
terminals.

11B-209.2.2 Bus Loading
Zones

Scoping for bus loading zones.

1121B.2.1 New construction.

•
•
•
•
•
•
•

Technical requirements for bus boarding,
alighting areas and bus shelters.

1121B.2.2 Bus stop siting and
alterations.

11B-810.2.1 Surface
11B-810.2.2 Dimensions
11B-810.2.3 Connections
11B-810.2.4 Slope
11B-810.3 Bus Shelters
11B-810.4 Bus Signs
11B-705.1.2.4 Bus Stops

Technical requirements for detectable
warnings and square curbs.

• 11B-209.2.2 Bus Loading
Zones
• 11B-209.2.3 On-Street Bus
Stops
• 11B-218.4 Bus Shelters

Scoping for bus loading zones.

1.

11B-402.2 Accessible Route
Components

Technical requirements for components of
accessible routes.

2.

11B-810.4 Bus Signs

Technical requirements for bus signs.

• 11B-218 Transportation
Facilities

Scoping for transportation facilities

• 11B-810 Transportation
Facilities

Technical requirements for transportation
facilities

11B-201.1 Scope

Scoping for new construction and
alterations for facilities.

• 11B-206.3 Location
• 11B-216.6 Entrance

Scoping for location of accessible route to
coincide with general circulation path.
Scoping for signage located where
accessible route diverges from regular
circulation path.

• 11B-206.4.1 General
• 11B-206.4.4 Transportation
Facilities

Scoping requires all entrances and
exterior ground-floor exit doors to
buildings and facilities to be accessible.

1121B.3 Fixed facilities and
stations.

1121B.3.1 New construction.

1.

2.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1121B – Transportation Facilities

Page 59 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

3.

• 11B-206.2.1 Site Arrival
Points
• 11B-206.4.2.2 Direct
Connections

Scoping for accessible route provided
within the site to facilities and
transportation stops.

4.

• 11B-216.6 Entrances
• 11B-810.6.1 Entrances

Scoping for signage located at entrances.
Technical requirements for signage at rail
stations.

5.

• 11B-810.6 Entrances
• 11B-810.6.3 Station Names

Technical requirements for signage at rail
stations.

6.

11B-810.6.2 Routes and
Destinations

Technical requirements for signage at rail
stations.

7.

• 11B-220.1 General Automatic
Teller and Fare Machines and
Point-of-Sale Devices

Scoping for fare machines.

• 11B-707.2 Clear Floor and
Ground Space

Technical requirements for fare machines.

• 11B-404 Doors, Doorways,
and Gates

Technical requirements for doors and
gates.

11B-810.5.2 Detectable
Warnings

Technical requirements for detectable
warnings at platform edges.

• 11B-705.1.2.1 Platform Edges

Technical requirements for detectable
warnings at platforms edges.
Technical requirements for detectable
warnings.

2010 CBC Chapter 11B

8.

(a) Detectable warnings
at transit boarding
platforms.

(b) Detectable
directional texture at
boarding platforms.

9.

Exception 1

• 11B-705.1 Detectable
Warnings
• 11B-705.3 Product Approval

Technical requirements for product
approval.

• 11B-705.1.1.3 Contrast

Technical requirements for contrast
formula.

• 11B-705.2 Detectable
Directional Texture

Technical requirements for detectable
directional texture.

• 11B-705.3 Product Approval

Technical requirements for product
approval.

11B-810.5.3 Platform and
Vehicle Floor Coordination

Technical requirements for platform and
vehicle floor coordination.

11B-810.5.3 Platform and
Vehicle Floor Coordination

Technical requirements for platform and
vehicle floor coordination.
Requirements further defined in 36 CFR
Part 1192.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1121B – Transportation Facilities

Page 60 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

11B-810.5.3 Platform and
Vehicle Floor Coordination

Technical requirements for platform and
vehicle floor coordination.
Requirements further defined in 36 CFR
Part 1192.

10.

11B-810.1 Vehicle Boarding

Technical requirements for vehicle
boarding.

11.

N/A

Not carried forward

12.

11B-217.4 TTYs

Technical requirements for TTYs

a.

11B-217.4.1 Bank Requirement
11B-217.4.7 Transportation
Facilities

Scoping for required number of TTYs

b.

11B-217.4.3.1 Public Buildings

Scoping for required number of TTYs in
public buildings

11B-247.1.2.7 Track Crossings
11B-705.1.2.7 Track Crossings

Model code amended to provide scoping
and technical requirements for detectable
warnings at track crossings.

• 11B-218.5 Other
Transportation Facilities

Scoping requirement for public address
systems and visual format.

• 11B-810.7 Public Address
Systems

Technical requirement for public address
systems and visual format.

• 11B-218.5 Other
Transportation Facilities

Scoping requirement for public address
systems and visual format.

• 11B-810.8 Clocks

Technical requirements for clocks.

16.

11B-810.9 Escalators

Technical requirements for escalators.
Additional requirements defined in ASME
A17.1

17.

N/A

Not carried forward, security issue not
access related.

N/A

Related to Item 17, not carried forward.

• 11B-904.4 Sales and Service
Counters
• 11B-904.4.1 Parallel
Approach
• 11B-904.4.2 Forward
Approach

Technical requirements for sales and
service counters.

2010 CBC Chapter 11B

Exception 2

13.

14.

15.

Exception
18.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1121B – Transportation Facilities

Page 61 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

• 11B-810.1.3 Baggage
Retrieval Systems

Technical requirements for baggage
retrieval systems.

• 11B-206.8 Security Barriers

Scoping for security barriers.

• 11B-404.2.10 Door and Gate
Surfaces

Technical requirements for gates.

1121B.3.2 Existing facilities—
alterations.

• 11B-202.3 Alterations
• 11B-202.4 Path of Travel
• 11B-218.2 New and Altered
Fixed Guideway Systems.

Scoping for alterations in transportation
facilities.

1121B.4 Airports.

N/A

Title only in 2010 CBC.

1121B.4.1 New construction.

• 11B-201.1 Scope
• 11B-218.5 Other
Transportation Facilities

Scoping for all areas of newly designed
and constructed buildings and facilities.

1.

11B-206.3 Location

Scoping for location of accessible route to
coincide with general circulation path.

2.

11B-216.6 Entrance

Scoping for signage located where
accessible route diverges from regular
circulation path.

3.

• 11B-904.4 Sales and Service
Counters
• 11B-904.4.1 Parallel
Approach
• 11B-904.4.2 Forward
Approach

Technical requirements for sales and
service counters.

4.

• 11B-217.4.1 Bank
Requirement
• 11B-217.4.7 Transportation
Facilities

Scoping for required number of TTYs

5.

• 11B-810.1.3 Baggage
Retrieval Systems

Technical requirements for baggage
retrieval systems.

• 11B-206.8 Security Barriers

Scoping for security barriers.

• 11B-404.2.10 Door and Gate
Surfaces

Technical requirements for gates.

• 11B-218.5 Other
Transportation Facilities

Scoping requirement for public address
systems and visual format.

• 11B-810.7 Public Address
Systems

Technical requirement for public address
systems and visual format.

11B-810.8 Clocks

Technical requirements for clocks.

2010 CBC Chapter 11B

19.

6.

7.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1121B – Transportation Facilities

Page 62 of 106
5 February 2013

Section 1122B Fixed or Built-In Seating, Tables and Counters
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1122B.1 Minimum number.

• 11B-206.2.4 Spaces and
Elements
• 11B-226.1 General

Scoping for fixed or built-in seating or
tables

1122B.2 Seating.

11B-902.2 Clear Floor or
Ground Space

Technical requirements for clear floor
space

1122B.3 Knee clearance.

•
•
•
•

Technical requirements for knee and toe
clearance

Exception

11B-306.2.3, Exception 2
11B-306.3.3, Exception 3
11B-306.3.4, Exception 2
11B-902.2 Clear Floor or
Ground Space

11B-226.1, Exception 1

Exception for knee and toe clearance at
sales and service counters

1122B.4 Height of work
surfaces.

• 11B-226.1 General
• 11B-902.3 Height

Scoping and technical requirements for
height of work surfaces

1122B.5 Sales and service
counters, teller windows and
information counters.

• 11B-227.3 Counters
• 11B-904.4 Sales and Service
counters

Scoping and technical requirements for
sales and service counters

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1122B - Fixed or Built-In Seating, Tables and Counters

Page 63 of 106
5 February 2013

Section 1123B Access to Employee Areas
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1123B.1 General.

11B-203.9 Employee Work
Areas

General scoping for employee work areas

1123B.2 Work stations.

• 11B-203.9 Employee Work
Areas
• 11B-206.2.8 Employee Work
Areas

General scoping for employee work areas
– including accessible route

• 11B-203.3 Raised Areas
• 11B-203.4 Limited Access
Spaces
• 11B-203.5 Machinery Spaces

Exception to the requirements of
accessibility

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1123B Access to Employee Areas

Page 64 of 106
5 February 2013

Section 1124B Ground and Floor Surfaces
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1124B.1 General.

• 11B-302 Floor and Ground
Surfaces
• 11B-302.1 General

Technical requirements for floor and
ground surfaces – slip resistance

1124B.2 Changes in level.

11B-303 Changes in Level

Technical requirements for floor and
ground surfaces – changes in level

1124B.3 Carpet.

11B-302.2 Carpet

Technical requirements for floor and
ground surfaces – carpet

1124B.4 Gratings.

11B-302.4 Openings

Technical requirements for floor and
ground surfaces – openings or gratings

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1124B Ground and Floor Surfaces

Page 65 of 106
5 February 2013

Section 1125B Storage
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1125B.1 General.

11B-225.2 Storage

Scoping for storage

1125B.2 Clear floor space.

11B-811.2 Clear Floor or
Ground Space

Technical requirements for storage

1125B.3 Height.

11B-811.3 Height

Technical requirements for storage

1125B.4 Hardware.

11B-811.4 Operable Parts

Technical requirements for storage

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1125B Storage

Page 66 of 106
5 February 2013

Section 1126B Vending Machines and Other Equipment
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1126B Vending machines and
other equipment

• 11B-228 Depositories,
Vending Machines, Change
Machines, Mail Boxes and
Fuel Dispensers

Scoping for vending machines and other
type of equipment

• 11B-309 Operable Parts

Technical requirements for operable parts

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1126B Vending Machines and Other Equipment

Page 67 of 106
5 February 2013

Section 1127B Exterior Routes of Travel
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1127B.1 General.

• 11B-206.2.1 Site Arrival
Points
• 11B-206.2.2 Within a Site
• 11B-206.3 Location
• 11B-206.4 Entrances

Scoping for site and entrance accessibility

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1127B.2 Design and
construction.

11B-201.1 Scope

Scoping for construction of buildings and
facilities

1127B.3 Signs.

11B-216.6 Entrances

Scoping for signs where accessible routes
diverge from the regular circulation path

1127B.4 Outside stairways.

N/A

1127B.5 Curb ramps.

• 11B-402.2 Components
• 11B-406 Curb Ramps,
Blended Transitions and
Islands

Scoping and technical requirements for
curb ramps

1. General.

11B-406.5.1 Location

Technical requirements for curb ramps –
location

2. Width of curb ramps.

11B-406.5.2 Width

Technical requirements for curb ramps –
width

3. Slope of curb ramps.

• 11B-406.2.1 Slope
• 11B-406.3.1 Slope
• 11B-406.4.1 Slope

Technical requirements for curb ramps slope

4. Level landing.

• 11B-406.2.2 Sides of Curb
Ramps
• 11B-406.5.3 Landings

Technical requirements for curb ramps –
landings and slope of curb ramp flares

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1127B Exterior Routes of Travel

Page 68 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

5. Finish.

N/A

Detectable warning satisfies the
requirement for contrast.

6. Border.

11B-406.5.11 Grooved Border

Technical requirements for curb ramps –
grooved border

7. Detectable warnings.

• 11B-406.5.12 Detectable
Warnings
• 11B-705.1.2.2 Curb Ramps

Technical requirements for curb ramps –
detectable warnings

8. Obstructions.

11B-406.5.1 Location

Technical requirements for curb ramps –
obstruction by parked vehicles

9. Diagonal curb ramps.

11B-406.5.10 Diagonal Curb
Ramps

Technical requirements for curb ramps –
diagonal curb ramps

Notes:

N/A

Generally incorporated into 11B-406.

2010 CBC Chapter 11B

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1127B Exterior Routes of Travel

Page 69 of 106
5 February 2013

Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses)
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1128B Pedestrian grade
separations (overpasses and
underpasses)

• 11B- 206.2.1 Site Arrival
Points
• 11B-206.2.2 Within a Site
• 11B-206.4.3 Entrances from
Tunnels or Elevated
Walkways

Scoping for accessible routes

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses)

Page 70 of 106
5 February 2013

Section 1129B Accessible Parking Required
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1129B.1 General.

• 11B-208.1 General.

Scoping for accessible parking

• 11B-208.3.1 General.

Requires parking to be on the closest
accessible route to the entrance,
dispersed when there are multiple
entrances and when parking doesn’t
serve a particular building to be on the
shortest accessible route to the entrance
of the parking facility.

• Table 11B-208.2 Parking
Spaces

The number of accessible spaces
required is shown in the table.

• 11B-208.2.1
• 11B-208.2.2, see below

Current 2010 CBC provisions are
included within the model code.

1129B.2 Medical care outpatient
facilities.
1. Outpatient units and
facilities.

11B-208.2.1 Hospital
Outpatient Facilities

Current 2010 CBC provisions are
included within the model code, which
expands the scope for a 10 percent
parking ratio to include all outpatient
facilities, not just those serving persons
with mobility impairments.

2. Units and facilities that
specialize in treatment or
services for persons with
mobility impairments.

11B-208.2.2 Rehabilitation
Facilities and Outpatient
Physical Therapy Facilities.

Current 2010 CBC provisions are
included within the model code.

11B-208.3.1 General.

Current redundant 2010 CBC reference
eliminated.

• 11B-502.2 Vehicle Spaces

Model code is being amended to carry
forward the current 2010 CBC minimum
width of 108 inches and minimum length
of 216 inches for standard accessible
spaces.

• 11B-502.3 Access Aisle.

Current provisions allowing two
accessible parking spaces to share an
access aisle are included within the
model code.

• 11B-502.3.3 Marking.

Current 2010 CBC provisions for marking
access aisles have been included by
amendment.

1129B.3 Parking space size.

1. Dimensions.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1129B Accessible Parking Required

Page 71 of 106
5 February 2013

2010 CBC Chapter 11B

2. Van space(s).

3. Arrangement of parking
space.

2013 CBC Chapter 11B

Comments

• 11B-208.2.4 Van Parking
Spaces.

Current 2010 CBC van to standard
parking space ratio of 1 to 8 has been
superseded by more stringent model
code requirement of 1 to 6.

• 11B-502.2 Vehicle Spaces

Model code is being amended to carry
forward the current 2010 CBC minimum
width of 144 inches and minimum length
of 216 inches for van spaces with the
option of a standard width accessible
parking space with a 96 inch minimum
width aisle.

• 11B-208.3.1, Exception 1

Current 2010 CBC provisions allowing
van parking spaces to be grouped on one
level within a multi-story parking facility
are included within the model code.

• 11B-502.3.3 Marking.

Current 2010 CBC provisions for marking
access aisles have been included by
amendment.

• 11B-502.3.4 Location.

Current 2010 CBC provisions requiring
access aisle for van spaces to be on the
passenger side have been included by
amendment.

11B-502.2 Vehicle Spaces

Current 2010 CBC requirement that a
person with a disability need not walk or
wheel behind any vehicle other than their
own is implemented by model code
language requiring access aisles to
adjoin an accessible route.

Exception 1.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1129B Accessible Parking Required

Page 72 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

4. Slope of parking space
and access aisle.

11B-502.4 Floor or Ground
Surfaces.

Model code language, with a nonsubstantive adjustment of the maximum
slope to 1:48 from 1:50, carries forward
the 2010 CBC requirements.

5. Vertical clearance.

11B-502.5 Vertical Clearance.

The required 98 inch overhead clearance
for both standard and van spaces and at
least one vehicular access route serving
them is carried forward to the 2013 CBC
by amendment.

1129B.4. Identification of parking
spaces for off-street parking
facilities.

• 11B-502.6 Identification,
including sub-sections

California statutory requirements for the
marking, identification and signage of
accessible off-street parking facilities are
carried forward to the 2013 CBC by
amendment.

• 11B-502.6.4.1 The outline of
the International Symbol of
Accessibility . . .
• 11B-703.7.2.1 International
Symbol of Accessibility.

California statutory requirements for the
surface marking of each accessible
parking space are carried forward to the
2013 CBC by amendment.
Current language referring to the
depiction of a wheelchair and its
occupant has been updated to a
reference to the International Symbol of
Accessibility.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1129B Accessible Parking Required

Page 73 of 106
5 February 2013

Section 1130B Parking Structures
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1130B.1

11B-502.5 Vertical Clearance.

The required 98 inch overhead clearance
is carried forward to the 2013 CBC.

Exception 1.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

11B-206.4.2 Parking Structure
Entrances

The requirement that each direct
pedestrian entrance from a parking facility
must be on an accessible route is
maintained in the 2013 CBC.

1130B.2

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1130B Parking Structures

Page 74 of 106
5 February 2013

Section 1131B Passenger Drop-Off and Loading Zones
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1131B.1 Location.

• 11B-209 Passenger Loading
Zones and Bus Stops
• 11B-209.1 General.

Scoping for passenger drop-off and
loading zones

1131B.2 Passenger loading
zones.

N/A

Title only in 2010 CBC

1. General.

• 11B-209.2 Type.
• 11B-503 Passenger Drop-Off
and Loading Zones

Scoping and technical requirements for
passenger drop-off and loading zones

2. Vertical clearance.

11B-503.5 Vertical Clearance.

Technical requirement to maintain 114
inch clearance

1131B.3 Valet parking.

11B-209.4 Valet Parking.

Scoping and technical requirements for
valet parking

1131B.4 Bus stop pads and
shelters.

• 11B-209.2.2 Bus Loading
Zones
• 11B-209.2.3 On-Street Bus
Stops.
• 11B-810.2 Bus Boarding and
Alighting Areas

Scoping and technical requirements for
bus stop pads and shelters

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1131B Passenger Drop off and Loading Zones

Page 75 of 106
5 February 2013

Section 1132B Outdoor Occupancies
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1132B.1 General.

• 11B-201.1 Scope.

All areas of newly designed and newly
constructed buildings and facilities and
altered portions of existing buildings and
facilities shall comply with these
requirements.
Scoping for parks and recreational areas

• 11B-246 Parks and
Recreational Areas.
1132B.2 Parks and recreational
areas.

11B-246.1 General.

Scoping for parks and recreational areas

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

11B-246.1 General, Exception

The existing exception to preclude
material damage to the natural
environment has been carried forward.

Exception 3

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1. Campsites.

11B-246.2 Camping Facilities.

Current 2010 CBC provisions have been
included by amendment.

2. Beaches, picnic areas.

• 11B-246.1 General

Current 2010 CBC provisions have been
included by amendment.
Requirement for accessible picnic tables
has been clarified at a level consistent
with the ratios for dining areas.
Current levels of access are maintained
by the requirement for accessible routes
to buildings and other functional areas

• 11B-246.3 Beaches.

• 11B-246.4 Day Use Areas
and Vista Points
• 11B-246.5 Picnic Areas
3. Sanitary facilities.

11B-213 Toilet Facilities and
Bathing Facilities

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1132B Outdoor Occupancies

Scoping for toilet and bathing facilities

Page 76 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

4. Boat docks.

• 11B-235 Recreational Boating
Facilities
• 11B-1003 Recreational
Boating Facilities
• 11B-237 Fishing Piers and
Platforms
• 11B-1005 Fishing Piers and
Platforms

The model code’s specific provisions
provide enforceable requirements in lieu
of the current 2010 CBC general
statement of intent.

5. Parking lots.

11B-502.1 General.

Technical requirements for parking

6. Trails and paths.

11B-246.7 Trails and Paths.

Current 2010 CBC provisions have been
included by amendment.

7. Nature trails.

11B-246.8 Nature Trails.

Current 2010 CBC provisions have been
included by amendment.

1132B.3 Highway rest areas.

11B-201.1 Scope.

As a primary function area, the facilities at
a highway rest stop will need to comply
with the ADA and the 2013 CBC, which
requires that “All areas of newly designed
and newly constructed buildings and
facilities and altered portions of existing
buildings and facilities shall comply with
these requirements.”

1132B.3.1 Permanent facilities.

11B-201.1 Scope.

These limited specific references are
provided for in the overall 2013 Chapter
11B; the current provisions are redundant.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1132B Outdoor Occupancies

Page 77 of 106
5 February 2013

Section 1133B General Accessibility for Entrances, Exits and Paths of Travel
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.1 Building accessibility.

11B-206.4 Entrances

General scoping for entrances

1133B.1.1 Entrances.

11B-206.4 Entrances

General scoping for entrances

1133B.1.1.1 Entrances and
exterior ground floor exit doors.

11B-206.4 Entrances

General scoping for entrances

1133B.1.1.1.1

• 11B-206.2.1 Site Arrival
Points
• 11B-206.2.2 Within a Site
• 11B-206.2.4 Spaces and
Elements
• 11B-206.4 Entrances
• 11B-404.2.3 Clear Width

Scoping and technical requirements for
entrances – connection to public
transportation stops, passenger loading
zones, parking and all accessible spaces
and elements within the building or
facility.
Technical requirements differ from ADAS
by requiring all entrances and exterior
ground floor exits to be accessible
Exception for exterior ground floor exits
serving smoke-proof enclosures,
stairwells and exit doors servicing stairs
only

Exception 1

11B-206.4.1, Exception 1

Exception 2

11B-206.4.1, Exception 2

Exception for exits in excess of those
required by Chapter 10 and more than 24”
above grade

Exception 3

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 4

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.1.1.1.2 Temporary
restrictions.

11B-108 Maintenance of
Accessible Features

Scoping for maintenance of accessible
features.

1133B.1.1.1.3 Recessed
doormats.

• 11B-302.1 Floor or Ground
Surfaces

Technical requirements for floor or ground
surfaces.

• 11B-302.2 Carpet

Technical requirement for carpet.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 78 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.1.1.1.4 Gates.

11B-206.5 Doors, Doorways
and Gates

General scoping for doors, doorways and
gates

1133B.1.1.1.5 Service
entrances.

11B-206.4.8 Service Entrances

Model code amended to require service
entrance shall not be the sole accessible
entrance unless it is the only entrance to
a building or facility.

1133B.2 Doors.

• 11B-206.5 Doors, Doorways
and Gates
• 11B-404.1 General

General scoping and technical
requirements for doors, doorways and
gates

1133B.2.1 Type of lock or latch.

• Chapter 10, Section 1008.1.9
Door operations
• 11B-404.2.7 Door and Gate
Hardware

Technical requirements for door
operations

1133B.2.2 Width and height.

11B-404.2.3 Clear Width

Technical requirements for door – width,
height and clear width. Provides for
consistency with 2010 ADAS and Chapter
10 CBC.

11B-404.2.3 Clear Width
Exception 3

Model code amended for doors not
requiring full user passage, such as at
shallow closets – 20” minimum clear
opening.

1133B.2.3 Hinged doors.

11B-404.2.3 Clear Width

Technical requirements for doors –
openings measured with door open 90
degrees

1133B.2.3.1 Pairs of doors.

• 11B-404.2.2 Double-Leaf
Doors and Gates
• 11B-404.2.3 Clear Width

Technical requirements for doors – pairs
of doors

1133B.2.3.2 Automatic and
power-assisted doors.

11B-404.3 Automatic and
Power-Assisted Doors and
Gates

Technical requirements for doors –
automatic and power-assisted doors

Exception 1

11B-404.2.3, Exception 1

Exception to the door clear width
requirements in alterations

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 79 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.2.3.3 Revolving doors.

11B-404.2.1 Revolving Doors,
Gates and Turnstiles

Technical requirements for doors –
revolving doors shall not be part of an
accessible route

1133B.2.3.4 Turnstiles, rails and
pedestrian controls.

11B-206.3 Location

Scoping for location of accessible route to
coincide with or be located in the same
area as general circulation paths.

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.2.4 Floor level at doors.

11B-404.2.4.4 Floor or Ground
Surface

Technical requirements for doors -

1133B.2.4.1 Thresholds.

11B-404.2.5 Thresholds

Technical requirements for doors –
thresholds

1133B.2.4.2 Maneuvering
clearances at doors.

• 11B-404.2.4 Maneuvering
Clearances
• 11B-404.2.4.4 Floor or
Ground Surface

Technical requirements for doors –
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors

• 11B-404.2.4 Maneuvering
Clearances
• 11B-404.2.4.4 Floor or
Ground Surface

Technical requirements for doors –
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors

1133B.2.4.3

• 11B-404.2.4 Maneuvering
Clearances

Technical requirements for doors –
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors

1133B.2.4.4

11B-404.2.6 Doors in Series
and Gates in Series

Technical requirements for doors – doors
in series

1133B.2.4.5 Recessed doors.

11B-404.2.4.3 Recessed Doors
and Gates

Technical requirements for doors –
recessed doors

1133B.2.5 Door opening force.

11B-404.2.9 Door and Gate
Opening Force

Technical requirements for doors –
opening force

1.

11B-404.2.9, Item 3

Technical requirements for doors –
opening force for required fire doors

2.

11B-404.2.9, Item 1 & 2

Technical requirements for doors –
opening force for interior doors

Exception

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 80 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

3.

11B-404.2.9,Item 4

Technical requirements for doors –
opening force for exterior doors

Exception 1

11B-404.2.9, Exception 1

Exception for doors to machinery spaces

Exception 2

11B-404.2.9, Exception 2,
including items a through e

Exception for banks of doors

1133B.2.5.1 Door closer.

11B-404.2.8.1 Door Closers
and Gate Closers

Technical requirements for doors – door
closer speed

1133B.2.5.2

• 11B-404.2.7 Door and Gate
Hardware
• 11B-309.4 Operation

Technical requirements for doors – door
hardware

1133B.2.6 Smooth surface.

11B-404.2.10 Door and Gate
Surfaces

Technical requirements for doors –
surfaces within 10 inches of the floor

1133B.3 Corridors, hallways and
exterior exit balconies.

11B-403.5.1, Clear Width

General technical requirements for width
of accessible routes

1133B.3.1 Corridor and hallway
widths.

11B-403.5.1, Exception 2

Exception to the requirement for a 36”
minimum wide accessible route –
corridors serving an occupant load of 10
or more require a 44” minimum width

1133B.3.2 Corridors and
hallways over 200 feet (60 960
mm).

11B-403.5.3 Passing Spaces

Technical requirements for corridors and
hallways over 200 feet – 60” width or
passing spaces

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.4 Stairways.

11B-210.1 General

Scoping for stairways

1133B.4.1 Handrails.

• 11B-504.6 Handrails
• 11B-505 Handrails

Technical requirements for handrails at
stairways

2010 CBC Chapter 11B

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 81 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.4.1.1 Required handrails.

• 11B-505.2 Where Required
• 11B-505.3 Continuity

Technical requirements for handrails at
stairways – along both sides, continuous

1133B.4.2 Handrail
configuration.

N/A

1133B.4.2.1

11B-505.4 Height

Technical requirements for handrails at
stairways – height

1133B.4.2.2

• 11B-505.10 Handrail
Extensions
• 11B-505.10.2 Top Extension
at Stairs
• 11B-505.10.3 Bottom
Extension at Stairs

Technical requirements for handrails at
stairways – extensions at top and bottom

Exception 1

11B-505.3 Continuity

Technical requirements for handrails at
stairways – switchback or dogleg stairs

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.4.2.3

• 11B-505.10 Handrail
Extensions
• 11B-505.10.2 Top Extension
at Stairs
• 11B-505.10.3 Bottom
Extension at Stairs

Technical requirements for handrails at
stairways – extensions at top and bottom

1133B.4.2.4

• 11B-505.10 Handrail
Extensions

Technical requirements for handrails at
stairways – handrail orientation

1133B.4.2.5

11B-505.5 Clearance

Technical requirements for handrails at
stairways - clearance

1133B.4.2.6 Handgrips.

• 11B-505.6 Gripping Surface
• 11B-505.7 Cross Section
• 11B-505.8 Surfaces

Technical requirements for handrails at
stairways – gripping surface

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 82 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.4.3 Tactile floor
identification signs in stairways.

11B-504.8 Floor Identification

Technical requirements for stairways –
tactile floor level identification signs
This requirement was brought forward
from the 2010 CBC, not a requirement of
the 2010 ADAS

1133B.4.4 Striping for the
visually impaired.

11B-504.4.1 Contrasting Stripe

Technical requirements for stairways –
contrasting stripe
This requirement was brought forward
from the 2010 CBC, not a requirement of
the 2010 ADAS

1133B.4.5 Stair treads, risers
and nosing.

11B-504.2 Treads and Risers

Technical requirements for stairways tread depth and riser height

1133B.4.5.1 Treads.

• 11B-504.4 Tread Surface
• 11B-504.7 Wet Conditions

Technical requirements for stairways –
tread surface slip resistance and wet
conditions

1133B.4.5.2 Risers.

• 11B-504.3 Open risers
• 11B-504.5 Nosings

Technical requirements for stairways –
open risers not permitted and riser slope

Exception 1

11B-504.3, Exception 1

Exception for open risers at exterior
stairways – ½” opening

Exception 2

11B-504.3, Exception 2

Exception for open risers at exterior
stairways – grating

11B-504.5 Nosings

Technical requirements for stairways –
nosings

11B-504.5, Exception

Exception for existing buildings

2010 CBC Chapter 11B

1133B.4.5.3 Nosing.

Exception 1

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 83 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 3

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.5 Ramps.

• 11B-402.2 Components
• 11B-405 Ramps

General technical requirements for ramps

1133B.5.1 General.

• 11B-403.3 Slope
• 11B-405.1 General

Technical requirements for ramps - slope

1133B.5.2 Width

11B-405.5 Clear Width

Technical requirements for ramps - width

1133B.5.3 Slope.

• 11B-405.2 Slope
• 11B-405.6 Rise

Technical requirements for ramps –
maximum slope and rise

1133B.5.3.1

11B-405.3 Cross Slope

Technical requirements for ramps –
maximum cross slope

1133B.5.4 Landings.

• 11B-405.7 Landings
• 11B-405.7.1 Slope

Technical requirements for ramp landings
– general requirement for level landings

1133B.5.4.1 Location of
landings.

• 11B-405.6 Rise
• 11B-405.7 Landings

Technical requirements for ramp landings
– top and bottom landings at each ramp
run, rise of any ramp run not to exceed
30” maximum

1133B.5.4.2 Size of top and
bottom landings.

•
•
•
•

Technical requirements for ramp landings
– dimensions of top and bottom landings

1133B.5.4.3 Doors at ramp
landings.

11B-405.7.5 Doorways

Technical requirements for ramp landings
– doors at landings

1133B.5.4.4 Encroachment of
doors at ramp landings.

11B-405.7.5 Doorways

Technical requirements for ramp landings
– doors at landings

2010 CBC Chapter 11B

11B-405.7.2 Width
11B-405.7.2.1 (Top landings)
11B-405.7.3 Length
11B-405.7.3.1 (Bottom
landings)

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 84 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.5.4.5 Landing width.

11B-405.7.2 Width

Technical requirements for ramp landings
– width

1133B.5.4.6 Change of direction.

11B-405.7.4 Change in
Direction

Technical requirements for ramp landings
– change in direction

1133B.5.4.7 Other intermediate
landings.

11B-405.7.3 Length

Technical requirements for ramp landings
– length of intermediate landings

1133B.5.4.8

• 11B-405.7.2 Width
• 11B-405.7.3 Length

Technical requirements for ramp landings
– dimensions of top and bottom landings

1133B.5.4.9 Hazards.

• 11B-405.9 Edge Protection
• 11B-405.9.2 Curb or Barrier

Technical requirements for ramps – edge
protection

1133B.5.5 Handrails for ramps.

11B-405.8 Handrails

1133B.5.5.1

• 11B-405.8 Handrails
• 11B-307.2 Protrusion Limits
Exception
• 11B-505.1 General
• 11B-505.2 Where Required
• 11B-505.3 Continuity
• 11B-505.4 Height
• 11B-505.5 Clearance
• 11B-505.6 Gripping Surface
• 11B-505.7 Cross Section
• 11B-505.8 Surfaces
• 11B-505.9 Fittings
• 11B-505.10 Handrail
Extensions
• 11B-505.10.1 Top and Bottom
Extension at Ramps

General technical requirements for ramp
handrails
Technical requirements for ramp
handrails – continuity, height, clear
between wall, gripping surface
dimensions, smooth surfaces, fittings and
top and bottom extensions

Provision for handrails to project into the
required clear width a distance of 3-1/2
inches from each side of a ramp at the
handrail height not carried forward to
allow for 2010 ADAS non-circular handrail
cross section.
Exception 1

11B-405.8, Exception 2

Exception for handrails adjacent to fixed
seating in assembly areas

Exception 2

11B-405.8, Exception 3

Exception for handrails at curb ramps

Exception 3

11B-405.8, Exception 4

Exception for handrails at door landings at
ramps less than 6” in rise or 72” in length

11B-505.10 Handrail
Extensions
Exception 3

Model code amended to add handrail
extension at hazard turned 90 degrees.

1133B.5.5.1.1 Ramp handrails.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 85 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.5.6 Guide curbs and
wheel guide rails.

• 11B-405.9 Edge Protection
• 11B-405.9.2 Curb or Barrier

Technical requirements for ramps – edge
protection

1133B.5.6.1

11B-405.9.2 Curb or Barrier

Technical requirements for ramps – edge
protection

1133B.5.6.2

11B-405.9.2 Curb or Barrier

Technical requirements for ramps – edge
protection

1133B.5.7 Guards.

Chapter 10, Section 1013.2
Where required

Technical requirements for guards at
ramps located more than 30 inches above
the floor.

1133B.5.8 Outdoor ramps.

11B-405.10 Wet Conditions

Technical requirements for ramps – wet
conditions

1133B.6 Aisles.

11B-403 Walking Surfaces

General technical requirements for aisles

1133B.6.1 General.

Chapter 10, Section 1017

General technical requirements for aisles

1133B.6.2 Width.

• 11B-403.5.1 Clear Width
• 11B-403.5.1, Exception

Technical requirements for aisle width

1133B.7 Walks and sidewalks.

• 11B-403 Walking Surfaces
• 11B-302.1 General

General technical requirements for walks
and sidewalks

1133B.7.1 Continuous surface.

• 11B-403.1 General
• 11B-403.2 Floor or Ground
Surface
• 11B-403.5.1, Exception 3
• 11B-403.5.3 Passing Spaces
• 11B-302.1 General

General technical requirements for walks
and sidewalks – continuous surface, no
abrupt level changes, 48” width, and
passing spaces

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.7.1.1 Slopes less than 6
percent.

11B-403.2 Floor or Ground
Surface

Technical requirements for walks and
sidewalks – slip resistant surface

1133B.7.1.2 Slopes 6 percent or
greater.

11B-403.2 Floor or Ground
Surface

Technical requirements for walks and
sidewalks – slip resistant surface

1133B.7.1.3 Surface cross
slopes.

11B-403.3 Slope

Technical requirements for walks and
sidewalks – slope and cross slope

Exception

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 86 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.7.2 Gratings.

11B-302.3 Openings

Technical requirements for walks and
sidewalks – gratings or openings

Exception 1

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

Exception 2

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

1133B.7.3 Five-percent gradient.

11B-401.1 Scope

Technical requirements for accessible
route components

1133B.7.4 Changes in level.

11B-403.4 Changes in Level

Technical requirements for walks and
sidewalks – changes in level

1133B.7.5 Level areas.

11B-403.7 Continuous Gradient

Technical requirements for walks and
sidewalks – level areas on continuous
gradients

1133B.8 Hazards.

N/A

1133B.8.1 Warning curbs.

11B-303.5 Warning Curbs

Technical requirements for changes in
level - warning curbs at abrupt changes in
level exceeding 4 inches
Requirements for warning curbs brought
forward from 2010 CBC, no comparable
requirement in the 2010 ADAS

1133B.8.2 Overhanging
obstructions.

11B-307.4 Vertical Clearance

Technical requirements for overhanging
obstructions – need for guardrails or
barriers where vertical clearance is less
than 80”

1133B.8.3 Detectable warnings
at transit boarding platforms.

11B-705.1.2.1 Platform Edges

Technical requirements for detectable
warning at platform boarding edges

1133B.8.4 Detectable directional
texture at boarding platforms.

11B-705.2 Detectable
Directional Texture

Technical requirements for directional
texture at platform boarding edges

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 87 of 106
5 February 2013

2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1133B.8.5 Detectable warnings
at hazardous vehicular
areas.
1133B.8.6 Protruding objects.

11B-705.1.2.5 Hazardous
Vehicular Areas

Technical requirements for detectable
warning at hazardous vehicular areas

• 11B-204 Protruding Objects
• 11B-307 Protruding Objects

General technical requirements for
protruding objects

1133B.8.6.1 General.

• 11B-307.2 Protrusion Limits
• 11B-307.3 Post-Mounted
Objects

Technical requirements for protruding
objects and post-mounted objects

1133B.8.6.2 Head room.

11B-307.4 Vertical Clearance

Technical requirements for overhanging
obstructions – need for guardrails or
barriers where vertical clearance is less
than 80”

1133B.8.6.3 Free-standing
signs.

• 11B-307.3 Post-Mounted
Objects
• 11B-307.3.1 Edges and
Corners

Technical requirements for post-mounted
objects and requirement to round or ease
the corners of signs

1133B.8.7 Detectable warnings
at reflecting pools.

11B-705.1.2.6 Reflecting Pools

Technical requirements for detectable
warning at reflecting pools

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel

Page 88 of 106
5 February 2013

Section 1134B – Accessibility for Existing Buildings
2013 CBC Chapter 11B

Comments

• 11B-201.1 Scope

Applies requirements to all areas of new
and altered buildings and facilities.
Renovations are considered an alteration

• 11B-202.1 General
• 11B-202.2 Additions

Applies requirements to additions to
existing buildings and facilities.

1134B.1 Scope, 2 paragraph

11B-202.3.1 Prohibited
Reduction in Access

Existing 2010 CBC requirement being
maintained.

1134B.2 General.

• 11B-202.2 Additions
• 11B-202.3 Alterations

Additions must comply with the
requirements for new construction. In
alterations each element or space altered
must comply with the requirements of
Division 2 and Section 11B-202 Existing
Buildings.

1134B.2.1 – Primary entrance . .
. primary path of travel . . . and
sanitary facilities, drinking
fountains, signs and public
telephones serving the area (of
alteration).

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs.

Existing 2010 CBC exceptions being
maintained.

Exception 1.
Disproportionate cost
exception with threshold.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

Existing 2010 CBC exceptions being
maintained.

1.1 through 1.6 - List of
elements in priority order for
disproportionate costs
exception.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8, Items 1
through 6.

Existing 2010 CBC exceptions being
maintained.

Exception 2. Certain types of
privately funded multi-story
buildings and facilities . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9.

Existing 2010 CBC exceptions being
maintained.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 1.

Existing 2010 CBC exceptions being
maintained.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 2.

Existing 2010 CBC exceptions being
maintained.

2010 CBC Chapter 11B
st

1134B.1 Scope, 1 paragraph

nd

2.1. Office buildings and
passenger vehicle service
stations . . .

2.2. Office of physicians
and surgeons.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1134B Accessibility for Existing Buildings

Page 89 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

2.3. Shopping centers.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 3.

Existing 2010 CBC exceptions being
maintained.

2.4. Other buildings and
facilities . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 4.

Existing 2010 CBC exceptions being
maintained.

Exception 3. Alterations . . .
limited to the actual work of
the project.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3.

Existing 2010 CBC exceptions being
maintained.

3.1. Altering one building
entrance . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 1.

Existing 2010 CBC exceptions being
maintained.

3.2. Altering on existing
toilet facility . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 2.

Existing 2010 CBC exceptions being
maintained.

3.3.Altering existing
elevators . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 3.

Existing 2010 CBC exceptions being
maintained.

3.4. Altering existing steps
...

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 4.

Existing 2010 CBC exceptions being
maintained.

3.5. Altering existing
handrails . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 5.

Existing 2010 CBC exceptions being
maintained.

3.6 Alterations solely for
the purpose of barrier
removal . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4.

Existing 2010 CBC exceptions being
maintained.

3.6.1. Installing Ramps

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 1.

Existing 2010 CBC exceptions being
maintained.

3.6.2. Making curb cuts .
..

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 2.

Existing 2010 CBC exceptions being
maintained.

2010 CBC Chapter 11B

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1134B Accessibility for Existing Buildings

Page 90 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

3.6.3. Repositioning
shelves

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 3.

Existing 2010 CBC exceptions being
maintained.

3.6.4. Rearranging . . .
furniture

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 4.

Existing 2010 CBC exceptions being
maintained.

3.6.5. Repositioning
telephones

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 5.

Existing 2010 CBC exceptions being
maintained.

3.6.6. Adding raised
markings on elevator
control buttons.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 6.

Existing 2010 CBC exceptions being
maintained.

3.6.7. Installing flashing
alarm lights

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 7.

Existing 2010 CBC exceptions being
maintained.

3.6.8. Widening doors.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 8.

Existing 2010 CBC exceptions being
maintained.

3.6.9 Installing offset
hinges . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 9.

Existing 2010 CBC exceptions being
maintained.

3.6.10 Eliminating a
turnstile or . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 10.

Existing 2010 CBC exceptions being
maintained.

3.6.11. Installing
accessible door
hardware

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 11.

Existing 2010 CBC exceptions being
maintained.

3.6.12. Installing grab
bars . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 12.

Existing 2010 CBC exceptions being
maintained.

3.6.13 Rearranging toilet
partitions . . .

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 13.

Existing 2010 CBC exceptions being
maintained.

2010 CBC Chapter 11B

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1134B Accessibility for Existing Buildings

Page 91 of 106
5 February 2013

2010 CBC Chapter 11B

3.6.14. Insulating
lavatory pipes . . .

2013 CBC Chapter 11B

Comments

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 14.

Existing 2010 CBC exceptions being
maintained.

11B-606.5 Exposed Pipes and
Surfaces

Technical requirements for protecting
exposed pipes and surfaces.

3.6.15 Installing a raised
toilet seat.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 15.

Existing 2010 CBC exceptions being
maintained.

3.6.16 Installing a full
length bathroom mirror.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 16.

Existing 2010 CBC exceptions being
maintained.

3.6.17 Repositioning
paper towel dispensers .
..

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 17.

Existing 2010 CBC exceptions being
maintained.

3.6.18 Creating
designated accessible
parking spaces.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 18.

Existing 2010 CBC exceptions being
maintained.

3.6.19 Installing a paper
cup dispenser at an
existing water fountain.

N/A

Existing 2010 CBC exceptions not carried
forward.

3.6.20 Removing highpile low-density
carpeting.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 19.

Existing 2010 CBC exceptions being
maintained.

3.6.21 Installing vehicle
hand controls.

N/A

The installation of vehicular hand control
is not a building code item and has not
been retained.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 5.

Existing 2010 CBC exceptions being
maintained.

11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 7.

Existing 2010 CBC exceptions being
maintained.

3.7 Altering existing
parking lots . . .

Exceptions: 4. Projects . . .
not considered alteration
projects . . .

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1134B Accessibility for Existing Buildings

Page 92 of 106
5 February 2013

2010 CBC Chapter 11B

1134B.2.2 Unisex toilet when
technically infeasible to install
separate toilet facilities for each
gender.

1134B.2.3 If alterations of Single
elements . . .

2013 CBC Chapter 11B

Comments

• 11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.

The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-bycase basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.

11B-202.3.3 Alterations of
Single Elements

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1134B Accessibility for Existing Buildings

Page 93 of 106
5 February 2013

Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings
with Historical Significance
2010 CBC Chapter 11B

2013 CBC Chapter 11B

Comments

1135B.1 General.

11B-202.5 Alterations to
Qualified Historic Buildings and
Facilities.

Current reference to State Historic
Building Code accessibility
provisions is maintained in 2013
CBC.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings
with Historical Significance

Page 94 of 106
5 February 2013

Chapter 11C – Standards for Card Readers at Gasoline Fuel-Dispensing Facilities
2013 CBC Chapter 11B

Comments

Accessible

Chapter 2 - Section 202

Definition of Accessible

Accessible Element

Chapter 2 - Section 202

Definition of Accessible Element

2010 CBC Chapter 11C

1101C.1 General.

Alternate Card Reader

Not carried forward

Free-Standing Pedestal

Not carried forward

Grade

Chapter 2 - Section 202

Definition of Grade

International Symbol of
Accessibility

Chapter 2 - Section 202

Definition of International Symbol of
Accessibility

Level Accessible Area

Not carried forward

Level Area

Chapter 2 - Section 202

Definition of Level Area

Recommend

Chapter 2 - Section 202

Definition of Recommend

Type of Motor Fuel
Section 1102C Application
1.

2.

Not carried forward
N/A
11B-201.1 Scope

Scoping for new construction and
alterations required to be accessible.

• 11B-201.1 Scope

Scoping for new construction and
alterations required to be accessible.
Does not address alteration as
removal and replacement of tanks,
piping or fuel dispensers.

2.1
2.2
• 11B-203.2 Alterations

Section 1103C Number of
Accessible Card Readers

11B-228 Depositories, Vending
Machines, Change Machines,
Mail Boxes, and Fuel
Dispensers

Scoping for number of fuel
dispensers required.

Section 1104C Required
Features

11B-228.1 General

Scoping for number of fuel
dispensers required to be
accessible.

• 11B-308.3.1 Unobstructed,
Exception 2.
• 11B-308.3.2 Obstructed High
Reach, Exception 2.

Technical requirements for reach
range at fuel dispensers.

1.

Exception:

Not carried forward

Cross Reference Guide - 2010 CBC to 2013 CBC
Chapter 11C – Standards for Card Readers at Gasoline Fuel-Dispensing Facilities

Page 95 of 106
5 February 2013

2013 CBC Chapter 11B

Comments

2.

11B-206.2.2 Within a Site

Scoping for accessible routes to
connect accessible elements on the
same site.

3.

• 11B-305.6 Approach

Location of clear floor or ground
space on accessible route.

• 11B-308.3.2 Obstructed High
Reach, Exception 2.

Technical requirements for reach
range at fuel dispensers.

2010 CBC Chapter 11C

Cross Reference Guide - 2010 CBC to 2013 CBC
Chapter 11C – Standards for Card Readers at Gasoline Fuel-Dispensing Facilities

Page 96 of 106
5 February 2013

Section 1101A Application
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Section 1101A APPLICATION

Chapter 1, Scope and
Administration
Reference to Chapter 1,
Section 1.1 General
1.1.3 Scope
1.1.3.2 State Regulated
Buildings, 7.

Comments

Reference to Chapter 1, Scope and
Application

Section 1.9 Division of the State
Architect
1.9.1.1 Application
1.9.1.1.3
1101A.1 Scope

N/A

Title only in 2010 CBC

1. All newly constructed….

11B-233.3.1 Minimum Number:
New Construction

Scoping for number of publicly housing
facilities with residential dwelling units.

2. New common use
spaces…

• 11B-203.8 Residential
Facilities
• 11B-206.2.3, Item 4. MultiStory Buildings and Facilities

General Scoping for common use areas
in residential facilities.

3. Additions to existing
buildings…

11B-233.3.3 Additions

General Scoping for additions to existing
public housing facility.

4. Common-use areas…

• 11B-203.8 Residential
Facilities
• 11B-206.2.3, Item 4. MultiStory Buildings and Facilities

General Scoping for common and public
use areas in residential facilities.

5. Where any portion of a
builing…

11B-233.3.4.1 Alterations to
Vacated Buildings.
Exception

General Scoping for alterations to vacated
buildings.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1101A Application

Page 97 of 106
5 February 2013

Section 1102A Building Accessibility
2010 CBC Chapter 11A

1102A Building Accessibility
1102A.1 Where required.

2013 CBC Chapter 11B

N/A

Comments

Title only in 2010 CBC

• 11B-104.2 Calculation of
Percentages
• 11B-233.3.1 Exception
• 11B-233.3.1.2.4 Exception
• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.

Scoping for number of units on a site that
must comply.

2. Condominiums …

• 11B-233.3 Residential
dwelling units not subject to
HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.

Scoping for residential dwelling units.

3. Lodging houses …

11B-224 Transient lodging
guest rooms

Scoping for transient lodging.

4. Congregate
Residences …

• 11B-224 Transient lodging
guest rooms.
• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.

Scoping for transient lodging and
residential dwelling units.

5. Dwelling with three or
more efficiency units …

• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.

Scoping for residential dwelling units.

6. Shelters for homeless
persons …

11B-224.1.5 Social service
center establishments.

Scoping for social service center
establishments.

7. Dormitories …

11B-224 Transient lodging
guest rooms.

Scoping for transient lodging.

8. Timeshare dwellings …

11B-224 Transient lodging
guest rooms.

Scoping for transient lodging.

9. Other Group R
occupancies …

• 11B-224 Transient lodging
guest rooms.
• 11B-233 Residential
facilities.

Scoping for transient lodging and
residential dwelling units.

1. Apartment Buildings …

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1102A Building Accessibility

Scoping for residential dwelling units.

Page 98 of 106
5 February 2013

2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

10. Publicly funded
housing, …

Chapter 2 - Definitions

Definition of public housing.

1102A.2 Existing buildings.

11B-233.3.4 Alterations

Scoping for alterations to public housing
facilities.

1102A.3 Multistory dwellings.

N/A

Title only in 2010 CBC

1102A.3.1 Multistory apartment
or condominium dwellings in
buildings with no elevator.

11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception

General Scoping for number of multistory
residential dwelling units required in nonelevator buildings.

• 11B-206.4.6 Residential
dwelling unit primary entry.
• 11B-233.3.1.2.5 Public
housing facility site
impracticability.
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception 2

General Scoping for residential dwelling
unit primary entrance and site
impracticality.

3. At rooms or spaces on
primary entry level …

11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception 3

General Scoping for accessible route on
primary entry level of multistory residential
dwelling unit.

4. Common use areas …

• 11B-203.8 Residential
facilities.
• 11B-206.2.3, Multi-story
buildings and facilities. Item 4.

General Scoping for common and public
use areas in residential facilities.

The minimum number of …..

11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception

General Scoping for number of multistory
residential dwelling units required in nonelevator buildings.

1102A.3.1 Multistory apartment
or condominium dwellings in
buildings with one or more
elevators.

11B-233.3.1.2.4 Multi-story
residential dwelling units.

General Scoping for number of multistory
residential dwelling units required in
buildings with one or more elevators.

11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception: Item 2

General Scoping for powder room on first
floor of multistory residential dwelling
unit.

11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception: Item 3

General Scoping for rooms or spaces on
accessible route with Chapter 11A,
Division IV – Dwelling Unit Features

1. The primary entry…

2. At least one powder
room….

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1102A Building Accessibility

General Scoping for powder room on first
floor of multistory residential dwelling
unit.

Page 99 of 106
5 February 2013

Section 1104A Covered Multifamily Dwellings
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

1104A.1 General.

• 11B-233.3.1.2.2 Non-elevator
buildings.
• 11B-233.3.1.2.5 Public
housing site impracticability.

General Scoping for residential dwelling
units required to be adaptable and
number exempted by site impracticality.

1104A.2 Ground floors above
grade.

11B-233.3.1.2.3 Ground floors
above grade.

General Scoping for residential dwelling
units with ground floor above grade.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1104A Covered Multifamily Dwellings

Page 100 of 106
5 February 2013

Section 1106A Site and Building Characteristics
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

11B-233.3.1.2.1 Elevator
buildings.

General Scoping for residential dwelling
units required to be adaptable in buildings
with elevator.

1106A.1 General Covered
multifamily dwellings with
elevators…..
2. Elevator building.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1106A Site and Building Characteristics

Page 101 of 106
5 February 2013

Section 1109A Parking Facilities
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

1109A.2.1 Private Garages.

11B-208.3.3

General Scoping for private garages
accessory to residential dwelling units.

Exception:

11B-208.3.3.2

1. A door leading…

11B-208.3.3.2, Item 1

General Scoping for access to residential
dwelling unit from private garage.

2. An accessible route…

11B-208.3.3.2, Item 2

General Scoping for access to residential
dwelling unit from private garage.

3. An accessible route…

11B-208.3.3.2, Item 3

General Scoping for access to residential
dwelling unit from private garage.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1109A Parking Facilities

Page 102 of 106
5 February 2013

Section 1114A Exterior Ramps and Landings on Accessible Routes
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

1114A.1 Width. The width of
ramps …
2. Ramps serving accessible
entrances ….

11B-405.5 Clear Width
Exception 3.

Cross Reference Guide - 2010 CBC to 2013 CBC
Section 1114A Exterior Ramps and Landings on Accessible Routes

Technical requirements for ramps serving
accessible entrance of residential dwelling
unit.

Page 103 of 106
5 February 2013

Division IV Dwelling Unit Features
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

Section 1130A Accessible route
within covered multi-family
dwelling units

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Section 1131A - Changes in
Level

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Section 1132A - Doors

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Section 1133A – Kitchens

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Section 1134A – Bathing and
Toilet Facilities

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Section 1135A – Laundry Rooms

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Cross Reference Guide - 2010 CBC to 2013 CBC
Division IV Dwelling Unit Features

Page 104 of 106
5 February 2013

2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

Section 1136A – Electrical
Receptacle, Switch and Control
Heights

11B-233.3.1.2 Residential
dwelling units with adaptable
features.

Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.

Cross Reference Guide - 2010 CBC to 2013 CBC
Division IV Dwelling Unit Features

Page 105 of 106
5 February 2013

Division VI Site Impracticality Tests
2010 CBC Chapter 11A

2013 CBC Chapter 11B

Comments

Section 1150A.1 Site
Impracticality Tests

11B-233.3.1.2.5 Public
Housing Facility Site
Impracticality.

Scoping for number of residential
dwelling units required after
determination of site impracticality.

Section 1150A.2, Additional
requirements
1. Grab bar reinforcement

11B-233.3.1.2.5 Public
Housing Facility Site
Impracticality.

Scoping for features in residential
dwelling units in remaining ground floor
residential dwelling units.

2. Doors
3. Communication features
4. Electrical receptacles
and switches
5. Toilet and bathing
facilities
6. Kitchen sink removable
cabinets

Cross Reference Guide - 2010 CBC to 2013 CBC
Division VI Site Impracticality Tests

Page 106 of 106
5 February 2013



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : DSA
Company                         : 
Create Date                     : 2013:02:15 10:17:15-08:00
Modify Date                     : 2013:02:15 10:18:40-08:00
Source Modified                 : D:20130215181657
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2013:02:15 10:18:40-08:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:76c1de0b-6dea-4fdd-a4ff-b3b54b681ce7
Instance ID                     : uuid:ddcb97f0-7edb-4489-8541-140b64e78d9a
Subject                         : 4
Format                          : application/pdf
Title                           : Cross Reference Guide 2013 Building Code Update for Accessibility
Creator                         : DSA
Producer                        : Adobe PDF Library 11.0
Page Layout                     : OneColumn
Page Count                      : 107
EXIF Metadata provided by EXIF.tools

Navigation menu