CROSS REFERENCE GUIDE
2013 Building Code Update for Accessibility
This document provides a cross reference between the accessibility provisions of the 2010 California
Building Code and the 2013 California Building Code as adopted by the California Building Standards
Commission on January 24, 2013.
This guide is organized as follows:
Provisions in the 2010 California Building Code (column one).
Corresponding provisions in the 2013 California Building Code (column two).
Commentary (column three).
Portions of the 2010 California Building Code, Chapter 11A not referenced in this document are either
duplicative, not as stringent or in conflict with 2013 Chapter 11B and are no longer adopted by the
Division of the State Architect Access Compliance.
February 5th, 2013
2013 California Building Code Update for Accessibility
Cross Reference Guide Accessibility provisions in the 2010 CBC to the 2013 CBC
Table of Contents
Chapter 11B - Accessibility to Public Buildings, Public Accommodations, Commercial Buildings
and Publicly Funded Housing
Section 1101B Scope ............................................................................................................................ 3
Section 1102B Definitions ...................................................................................................................... 4
Section 1103B Building Accessibility ..................................................................................................... 5
Section 1104B Accessibility for Group A Occupancies .......................................................................... 6
Section 1105B Accessibility for Group B Occupancies ........................................................................ 15
Section 1106B Accessibility for Group E Occupancies ........................................................................ 20
Section 1107B Factories and Warehouses .......................................................................................... 22
Section 1108B Accessibility for Group H Occupancies ........................................................................ 24
Section 1109B Accessibility for Group I Occupancies .......................................................................... 25
Section 1110B Accessibility for Group M Occupancies ........................................................................ 27
Section 1111B Accessibility for Group R Occupancies ........................................................................ 29
Section 1112B Reserved ..................................................................................................................... 34
Section 1113B Reserved ..................................................................................................................... 34
Section 1114B Facility Accessibility ..................................................................................................... 35
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) .......................................................... 37
Section 1116B Elevators and Platform (Wheelchair) Lifts .................................................................... 44
Section 1117B Other Building Components ......................................................................................... 48
Section 1118B Space Allowance and Reach Ranges .......................................................................... 56
Section 1119B Special Standards of Accessibility for Buildings with Historical Significance ................ 57
Section 1120B Floor and Levels .......................................................................................................... 58
Section 1121B Transportation Facilities ............................................................................................... 59
Section 1122B Fixed or Built-In Seating, Tables and Counters ............................................................ 63
Section 1123B Access to Employee Areas .......................................................................................... 64
Section 1124B Ground and Floor Surfaces .......................................................................................... 65
Section 1125B Storage ........................................................................................................................ 66
Section 1126B Vending Machines and Other Equipment ..................................................................... 67
Section 1127B Exterior Routes of Travel ............................................................................................. 68
Cross Reference Guide - 2010 CBC to 2013 CBC Page 1 of 106
Table of Contents February 5th 2013
Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses) .................................. 70
Section 1129B Accessible Parking Required ....................................................................................... 71
Section 1130B Parking Structures ....................................................................................................... 74
Section 1131B Passenger Drop-Off and Loading Zones ...................................................................... 75
Section 1132B Outdoor Occupancies .................................................................................................. 76
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel .................................... 78
Section 1134B Accessibility for Existing Buildings ............................................................................ 89
Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings with Historical
Significance ......................................................................................................................................... 94
Chapter 11C Standards for Card Readers at Gasoline Fuel-Dispensing Facilities ................... 95
Chapter 11AHousing Accessiblity
Section 1101A Application ................................................................................................................... 97
Section 1102A Building Accessibility ................................................................................................... 98
Section 1104A Covered Multifamily Dwellings ................................................................................... 100
Section 1106A Site and Building Characteristics ............................................................................... 101
Section 1109A Parking Facilities ....................................................................................................... 102
Section 1114A Exterior Ramps and Landings on Accessible Routes ................................................. 103
Division IV Dwelling Unit Features ..................................................................................................... 104
Division VI Site Impracticality Tests ................................................................................................... 106
Cross Reference Guide - 2010 CBC to 2013 CBC Page 2 of 106
Table of Contents February 5th 2013
Section 1101B Scope
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Section 1101B SCOPE
11B-107
Preserves reference to Chapter 1, Section
1.9.1.5 making the findings and
determinations rendered by a local
enforcement agency subject to ratification
through an appeals process.
1101B.1 General
N/A
Title only in 2010 CBC
1.
11B-101.1 General
General scoping for buildings and
facilities
2.
11B-103 Equivalent Facilitation
General scoping for equivalent facilitation
3.
11B-103 Equivalent Facilitation
General scoping for equivalent facilitation
1101B.2 Design
11B-101.1 General
General scoping for buildings and
facilities
1101B.3 Maintenance of
accessible features
11B-108 Maintenance of
Accessible Features
2010 ADAS addresses maintenance only
in advisory language; this section
maintains current CBC requirement.
1101B.4 Dimension
Conventions.
11B-104.1 Dimensions
Figure 11B-104 from ADA provides
graphic conventions for figures.
1101B.5 Constructing and
manufacturing tolerances.
11B-104.1.1 Construction and
Manufacturing Tolerances
All dimensions are subject to conventional
industry tolerances except where the
requirement is stated as a range with
specific minimum and maximum end
points.
1101B.6 Commercial facilities
located in private residences.
11B-245 Commercial Facilities
Located in Private
Residences
2010 ADA and 2010 CBC are equivalent.
This is a scoping provision and has been
included in Chapter 11B Division 2.
1101B.7 Provisions for Adults
11B-102 Dimensions for Adults
and Children
ADA and CBC equivalent.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 3 of 106
Section 1101B Scope 5 February 2013
Section 1102B Definitions
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1102B DEFINITIONS
11B-106 Definitions
Because California amendments to the
ADA Model Code language will be in
italics, defined terms within the code
language will not be shown italicized.
11B-106.5 Defined Terms
Chapter 2, Section 202
To conform to the format of the 2013
CBC, definitions will be located in Chapter
2, with a list of defined terms appearing in
11B-106.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 4 of 106
Section 1102B - Definitions 5 February 2013
Section 1103B Building Accessibility
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1103B.1 SCOPE
11B-101.1 General
This section establishes that the
requirements for accessibility are found in
Chapter 11B and applies them to sites,
facilities, buildings and elements to the
extent set forth in the regulations.
Second paragraph
11B-403.1 General
11B-403.5 Clearances
11B-403.5.1 Clear Width
11B-403.5.2 Clear Width at
Turns
11B-206.6 Elevators
Exception 1
11B-203.4 Limited Access
Spaces
11B-203.5 Machinery Spaces
11B-206.2.8 Exceptions 1, 2
& 3
Exception 2
11B-206.2.3
Both 2010 CBC and ADA do not require
ramp or elevator access to above or
below the first floor for certain small
facilities as noted in Exceptions 2.1 and
2.2.
Exception 2.1
11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 1
The specific 2010 CBC Exception
language for small office buildings and
passenger vehicle service stations has
been added to clarify that the second
condition in Exception 1 does not apply.
Exception 2.2
11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 1
The conditional language from the 2010
CBC Exception has been added to the
ADA language.
Third Paragraph
11B-213.2 Toilet Rooms and
Bathing Rooms
This section requires accessible toilet and
bathing facilities be provided on an
accessible route
Fifth Paragraph
11B-206.2.3.1 Stairs &
Escalators in Existing
Buildings
This section requires accessible route
when stair or escalator is provided in
alteration
1103B.2 Distance to Elevators
11B-206.2.3.2 Distance to
Elevators
This section from 2010 CBC for maximum
distance to elevators.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 5 of 106
Section 1103B Building Accessibility 5 February 2013
Section 1104B Accessibility for Group A Occupancies
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.1 General
11B-101.1 General
This section establishes that the
requirements for accessibility are found in
Chapter 11B and applies them to sites,
facilities, buildings and elements to the
extent set forth in the regulations.
1104B.2 Assistive listening
systems in assembly areas.
11B-219.2 Required Systems
Scoping for assistive listening systems;
amends model code language to remove
implied exception when audible
communications is not integral to the use
of the space.
Exception.
11B-219.2 Required Systems,
Exception: Paging, and
background music
Scoping for assistive listening systems;
amends model code language to narrow
scope of exception and maintain current
2010 CBC exception for paging and
background music systems.
1. Number of personal
receivers required
11B-219.3 Receivers
Scoping for number of receivers required;
amends model code language to maintain
current 2010 CBC requirements.
2. Types of listening systems
11B-706 Assistive Listening
Systems
Technical requirements for assistive
listening systems. Model code language
provides more detailed technical
performance specifications.
3. Location
11B-219.4 Location
Scoping for location of assistive listening
systems; amends model code with current
2010 CBC provisions regarding location
when not all seats are covered by the
assistive listening system.
4. Signage
11B-216.10 Assistive
Listening Systems
11B-703.5 Visual Characters
11B-703.7.2.4 Assistive
Listening Systems
Scoping for signage required for
availability of assistive listening systems.
Technical requirements for assistive
listening systems signage
5. Fees and Charges
N/A
Operational issue not enforceable by
building officials; current 2010 CBC
provisions not carried forward.
6. Permanent and Portable
Systems
11B-219.5 Permanent and
Portable Systems.
Scoping for permanent and portable
assistive listening systems; amends
model code with current 2010 CBC
provisions regarding permanent and
portable assistive listening systems.
1104B.3 Auditoriums, assembly
halls, theaters and related
facilities.
11B-221 Assembly Areas
Scoping for assembly areas.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 6 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.3.1 Seating
11B-221.1 General
Scoping for wheelchair spaces,
companion seats, designated aisle seats
and semi-ambulant seats.
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1104B.3.2 Accessibility to key
facilities.
11B-206.2.4 Spaces and
Elements
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.
1104B.3.3 Variety of locations.
11B-221.2 Wheelchair
Spaces
11B-221.2.1.2 Luxury Boxes,
Club Boxes, and Suites in
Arenas, Stadiums and
Grandstands.
11B-221.2.1.3 Other Boxes
11B-221.2.1.4 Team or Player
Seating
11B-221.2.3 Lines of Sight
and Dispersion
Scoping for accessible seating dispersion.
1104B.3.4 Wheel Chair Spaces
1. Number of such spaces is
as shown in table 11B-1.
11B-221.2 Wheelchair
Spaces
Table 11B-221.2.1.1 Number
of Wheelchair Spaces in
Assembly Areas
Scoping for the minimum number of
wheelchair spaces.
1104B.3.4 Wheel Chair Spaces
2. The ground or . . .
11B-802.1.1 Floor or Ground
Surface
Technical requirements for level floor or
ground surface at wheelchair spaces.
Slopes of 1:48 maximum are permitted.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 7 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.3.5 Placement of
wheelchair locations.
11B-221.2.2 Integration
• 11B-221.2.1.2 Luxury Boxes,
Club Boxes, and Suites in
Arenas, Stadiums and
Grandstands.
11B-221.2.1.3 Other Boxes
11B-221.2.1.4 Team or Player
Seating
11B-221.2.3 Lines of Sight
and Dispersion
11B-802.1.4 Approach
11B-207 Accessible Means of
Egress
11B-221.3 Companion Seats
Scoping for the number of wheel chair
spaces and their integration into the
seating plan, dispersion, sight lines and
other locational factors.
Technical requirements for adjoining
accessible route.
Scoping for companion seats at wheel
chair spaces.
Exception 1
11B-221.2.3.1 Horizontal
Dispersion, Exceptions
Scoping for dispersion where 300 or less
seating capacity.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1104B.3.6 Size of wheelchair
location.
11B-802.1 Wheelchair
Spaces
11B-802.1.4 Approach
Technical requirements for size of
wheelchair spaces.
Technical requirements for wheel chair
spaces to adjoin an accessible route.
1104B.3.7 Readily removable
seats.
N/A
Not allowed under the 2010 ADAS,
current 2010 CBC provisions not carried
forward.
1104B.3.8 Seating for semi-
ambulant individuals.
11B-221.1 General
11B-221.6 Semi-Ambulant
Seats
11B-802.5 Semi-Ambulant
Seats
Scoping for semi-ambulant seats; model
code has been amended to include 2010
CBC requirements.
Technical requirements for semi-ambulant
seats.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 8 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.3.9 Designated aisle
seats.
11B-802.4 Designated Aisle
Seats
11B-802.4.1 Armrests
11B-802.4.2 Identification
Technical requirements for designated
aisle seats.
1104B.3.10 Life safety.
N/A
Compliance with fire and life safety
requirements for all seats is mandated by
Chapter 10. Redundant 2010 CBC
provision not carried forward.
1104B.3.11 Access to
performing areas.
11B-206.2.6 Performance
Areas
Scoping for access to performance areas
including ancillary areas.
1104B.3.12 Stages, enclosed
and unenclosed platforms and
orchestra pits.
11B-206.7.1 Performance
Areas and Speakers
Platforms
Scoping to allow platform lifts to access
performance areas and speakers
platforms.
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1104B.3.13 Ticket booths.
Chapter 2 Section 202
11B-203.9 Employee Work
Areas
11B-206.2.4 Spaces and
Elements
• 11B-904.4 Sales and Service
Counters
Definition of Workstation
Scoping for Employee Work Area
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.
1104B.3.14 Miscellaneous
areas.
11B-206.2.4 Spaces and
Elements
Division 6: Plumbing
Elements and Facilities
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements, including toilet
facilities.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 9 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.4 Stadiums, grandstands,
bleachers, athletic pavilions,
gymnasiums, and miscellaneous
sports-related facilities.
N/A
Title only in 2010 CBC.
1104B.4.1 Spectator Seating
11B-221.1 General
202 DEFINITIONS
Assembly Area
Scoping for accessible seating
1104B.4.2 Ticket Booths
Chapter 2 Section 202
11B-203.9 Employee Work
Areas
11B-206.2.4 Spaces and
Elements
• 11B-904.4 Sales and Service
Counters
Definition of Workstation
Scoping for Employee Work Area
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.
1104B.4.3 Participation Areas
11B-206.2.4 Spaces and
Elements
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements.
1. Tennis, racquetball and
handball courts.
11B-206.2.4 Spaces and
Elements
11B-302.1 General, Exception
11B-303.1 General, Exception
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.
Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.
2. Gymnasium floor areas
and general exercise rooms.
11B-206.2.4 Spaces and
Elements
11B-302.1 General, Exception
11B-303.1 General, Exception
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.
Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant” with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 10 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
3. Basketball, volleyball and
badminton courts and
bowling lanes.
11B-206.2.4 Spaces and
Elements
11B-302.1 General, Exception
11B-303.1 General, Exception
Scoping for accessible route connecting
entrances, accessible spaces and
accessible elements up to the edge of the
areas of sport activity.
Model code technical exceptions from the
general requirement for areas of sport
activity to be “firm, stable and slip
resistant” with changes in level not
exceeding ½ inch. While areas of sport
activity for certain sports can meet these
requirements because of the inherent
nature of surface on which they are
played, many cannot.
4. Swimming pool deck
areas . . .
11B-242 Swimming Pools,
Wading Pools, and Spas
11B-1009 Swimming Pools,
Wading Pools, and Spas
Scoping for swimming pools, wading
pools, and spas.
Technical requirements for swimming
pools, wading pools, and spas.
4.1 Have a seat . . .
N/A
Title only in 2010 CBC.
4.1.1. Seat shall be
rigid . . .
11B-1009.2.4 Seat
Technical requirements for a rigid seat.
4.1.2. Seat height
11B-1009.2.4 Seat
Technical requirements for seat height.
4.1.3. Armrests
11B-1009.2.6 Footrests and
Armrests
Model code amended to add technical
requirements for two armrests.
4.1.4. Back support
11B-1009.2.4 Seat
Technical requirements for back support.
4.1.5. Occupant
restraint
11B-1009.2.4 Seat
Model code amended to add technical
requirements for seat restraint.
4.2 Be capable of . . .
11B-1009.2.7 Operation
Technical requirement for unassisted
operation.
4.3 Be stable and . . .
11B-1009.2.7 Operation
Model code amended to add technical
requirements for stable operation without
unintended movement.
4.4 Be designed to . . .
11B-1009.2.9 Lift Capacity
Technical requirements for lift capacity,
300 lbs. minimum.
4.5 Be positioned so . . .
11B-1009.2.1 Pool Lift Location
Exception 3
Technical requirements for water level.
4.6 Lower the operator .
. .
11B-1009.2.8 Submerged
Depth
Technical requirements for submerged
depth.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 11 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
5. Athletic team . . .
11B-206.2.2 Within a Site
11B-206.4 Spaces and
Elements
Scoping for accessible route connecting
accessible buildings, facilities, elements,
and spaces on the same site.
Scoping for accessible route connecting
entrances to accessible spaces and
elements within the building or facility.
1104B.4.4 Clubrooms.
11B-201.1 Scope
11B-222 Dressing, Fitting,
and Locker Rooms
11B-222.1 General
General scoping requirements.
Scoping based on use for Dressing,
Fitting, and Locker rooms.
1104B.4.5 Sanitary and locker
facilities.
11B-222 Dressing, Fitting,
and Locker Rooms
11B-222.1 General
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping based on use for Dressing,
Fitting, and Locker rooms.
Scoping for toilet and bathing facilities
1104B.5 Dining, banquet and bar
facilities.
N/A
Title only in 2010 CBC.
1. General.
11B-201.1 Scope
11B-226 Dining Surfaces and
Work Surfaces
11B-226.1 General
General scoping requirements.
Scoping for dining and work surfaces
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 12 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
2. Entrance.
11B-206.2.2 Within a Site
11B-206.4 Entrances
Scoping for accessible route connecting
accessible buildings, facilities, elements,
and spaces on the same site.
Scoping for entrances for buildings or
facilities .
3. Raised or sunken areas.
11B-206.2.5 Restaurants and
Cafeterias
11B-303.5 Warning Curbs,
Exception
Scoping for all dining areas, included
raised and sunken areas.
Scoping for warning curbs and guard or
handrails at the open edges of raised or
sunken areas.
4. Seating.
11B-226.1 General
11B-226.2 Dispersion
11B-226.3 Dining Surfaces
exceeding 34” in height.
11B-403.5.1 Clear Width,
Exception 4
11B-902.3 Height, Exception
Scoping for number of wheelchair spaces
at dining seating to be 5%.
Scoping for dispersion of wheel chair
spaces within seating for each type of
functional area.
Scoping for portion of dining surface of
60”in length
Technical requirements for clear width at
aisles.
Technical requirement for height of dining
and work surfaces.
5. Food service aisles.
11B-403.5.1 Clear Width,
Exception 4
11B-227.4 Food Service
Lines
11B-904.5 Food Service
Lines
Technical requirement for clear width at
aisles.
Scoping for self-service shelving at food
service lines.
Technical requirements for food service
aisles.
6. Tableware and condiment
areas.
11B-904.5.1 Self-Service
Shelves and Dispensing
Devices
Technical requirements for dispensing
tableware, dishware, condiments, food
and beverages.
7. Restrooms
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities
8. Food preparation areas.
Chapter 2 Section 202
11B-203.9 Employee Work
Areas
Definition of workstation
Scoping for access to employee work
areas.
1104B.6 Religious facilities.
N/A
Title only in 2010 CBC.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 13 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
2010 CBC Chapter 11B
2013 CBC Chapter 11B
Comments
1104B.6.1. General.
11B-244 Religious Facilities
Model code has been amended to include
scoping for religious facilities.
Exception.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1104B.6.2. Sanctuary.
11B-244 Religious Facilities
Scoping for religious facilities including
various areas within facility.
1104B.6.2.1. Wheelchair seating
. . .
11B-221.2.1.1 General Seating
Scoping for number of wheelchair spaces
required.
1104B.6.2.2. Wheelchair access
. . .
11B-206.2.6 Performance
Areas
Scoping for direct accessible route to
performance and ancillary areas.
Exception. In existing
buildings . . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1104B.6.3. Assembly areas.
11B-206.4 Spaces and
Elements
11B-206.2.6 Performance
Areas
Scoping for accessible routes connecting
entrances to accessible spaces and
elements within the building or facility.
Scoping for direct accessible route to
performance and ancillary areas..
1104B.6.4. Classrooms and
offices.
11B-206.4 Spaces and
Elements
Scoping for accessible route connecting
entrances to accessible spaces and
elements within the building or facility.
1104B.6.5. Sanitary facilities.
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities
Cross Reference Guide - 2010 CBC to 2013 CBC Page 14 of 106
Section 1104B Accessibility for Group A Occupancies 5 February 2013
Section 1105B Accessibility for Group B Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Section 1105B Accessibility for
Group B Occupancies
11B-101.1 General
General scoping for buildings and
facilities
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 3
11B-303 Changes in Level
• 11B-402.2 Components.
Technical requirements for changes in
level.
Technical requirements for accessible
routes
1105B.1 General.
N/A
Title only in 2010 CBC.
1105B.2 Group B occupancies.
11B-221 Assembly Areas
Based on use as an assembly area
Scoping for Assembly Areas will apply.
1105B.3 Office buildings and
personal and public service
facilities.
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
1105B.3.1 Facilities covered.
N/A
Title only in 2010 CBC.
1. All types of . . . business
professional offices, . . .
11B-106.5 Definitions
Section 202 DEFINITIONS
11B-201.1 Scope
Definition of Place of Public
Accommodation.
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 15 of 106
Section 1105B Accessibility for Group B Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
2. All types of sales
establishments . . .
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.
3. All personal and public
service facilities, . . .
11B-201 Application
11B-201.1 Scope
11B-217.4.6 Hospitals
11B-231 Judicial Facilities
11B-232 Detention Facilities
and Correctional
11B-611 Washing Machines
and Clothes Dryers
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.
Scoping for hospitals
Scoping for courtrooms
Scoping for detention and correctional
facilities.
Technical requirements for laundry
equipment.
4. . . . areas used for
businesses transactions with
the public . . .
11B-707.9.2 Point-of-sale
devices at check stands and
sales and services counters.
11B-226 Dining Surfaces and
Work Surfaces
11B-901.1 Scope
Technical requirements for point-of-sale
devices at check stands and sales and
service counters.
Scoping for dining surfaces and work
surfaces.
Technical requirements for built-in
elements.
1105B.3.2 Business and
professional offices.
Chapter 2 Section 202
Definition of Place of Public
Accommodation.
1. Client and visitor areas
and office areas, together
with related toilet rooms.
11B-201 Application
11B-201.1 Scope
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed in 2010 CBC
covered under this division.
Scoping for toilet and bathing facilities.
2. Conferences rooms,
counseling rooms or cubicles
and similar areas.
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed in 2010 CBC
covered under this division.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 16 of 106
Section 1105B Accessibility for Group B Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3. Employee work areas
shall have a minimum of 36
inch clear width access . . .
11B-203.9 Employee Work
Areas.
11B-403 Walking Surfaces
11B-403.5 Clearances,
Exception
11B-403.5.1 Clear Width
Scoping for employee work areas.
Technical requirements for walking
surfaces part of an accessible route.
Technical requirements for clearances
within employee work areas.
Technical requirements for clear width of
walking surfaces.
4. Professional medical and
dental offices . . .
11B-223.4 Professional
Offices of Health Care
Providers
11B-805 Medical Care and
Long Term Care Facilities
Scoping for offices of health care
providers.
1105B.3.3 Personal and public
service facilities.
Chapter 2 Section 202
Definition of Place of Public
Accommodation.
1. Client and visitor areas
and office areas, together
with related toilet rooms.
11B-201 Application
11B-201.1 Scope
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.
Scoping for toilet and bathing facilities.
2. Employee work areas
shall have a minimum of 36
inch clear width access . . .
11B-203.9 Employee Work
Areas.
11B-403 Walking Surfaces
11B-403.5 Clearances,
Exception
11B-403.5.1 Clear Width
Scoping for employee work areas.
Technical requirements for walking
surfaces part of an accessible route.
Technical requirements for clearances
within employee work areas.
Technical requirements for clear width of
walking surfaces.
3. Automated teller
machines . . . shall be on an
accessible route . . .
11B-206.2.2 Within a Site.
Scoping requirement for an accessible
route to connect accessible buildings,
facilities, elements and spaces on a site.
1105B.3.4 Public utility facilities.
Chapter 2 Section 202
Definition of Place of Public
Accommodation.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 17 of 106
Section 1105B Accessibility for Group B Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1. Office areas, meetings
rooms and similar areas . . .
11B-201 Application
11B-201.1 Scope
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed covered under
this division.
Scoping for toilet and bathing facilities.
2. Public tour areas, . . .
11B-206.2.2 Within a Site.
Scoping requirement for an accessible
route to connect accessible buildings,
facilities, elements and spaces on a site.
Exception 1. Facilities
located in operational
areas. . .
11B-203.5 Machinery Spaces
Scoping for accessible route at machinery
spaces.
Exception 2. . . .
unreasonable hardship, . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
3. Visitor overlook facilities . .
.
11B-201 Application
11B-201.1 Scope
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Types of facilities listed in the 2010 CBC
covered under this division.
Scoping for toilet and bathing facilities.
4. Where public parking is
provided . . .
11B-208 Parking Spaces
11B-502 Parking Spaces
Scoping requirements for parking.
Technical requirements for accessible
parking.
1105B.3.5 Police department,
law enforcement, Fire
Department facilities and
courtrooms.
11B-230.1 Judicial Facilities
11B-232 Detention Facilities
and Correctional Facilities
Scoping for judicial and correctional
facilities.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 18 of 106
Section 1105B Accessibility for Group B Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1. Office areas, conference
rooms, . . .
11B-201 Application
11B-201.1 Scope
11B-231.4 Visiting Areas
11B-213 Toilet and Bathing
Facilities
• 11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for visiting areas.
Scoping for toilet and bathing facilities.
2. Detention area visitor
rooms . . .
11B-232.5 Visiting Areas
Scoping for visiting areas.
3. At least one detention cell
. . .
11B-232 Detention Facilities
and Correctional Facilities
11B-807.2.4 Toilet and
Bathing Facilities
Scoping requirements for detention
facilities
Technical requirements for toilet and
bathing facilities provided as part of a cell.
4. Courtroom areas, . . .
11B-231.1 General
11B-808.4 Judges’ Benches
and Courtroom Stations.
11B-902 Dining Surfaces and
Work Surfaces
Scoping requirements for judicial facilities.
Technical requirements for judges’
benches and courtroom stations.
Technical requirements for work surfaces.
1105B.3.6 Miscellaneous
general standards.
N/A
Title only in 2010 CBC.
1. Circulation aisles and
pedestrian ways . . .
11B-403 Walking Surfaces
11B-403.1 General
11B-403.5 Clearances
11B-403.5.1 Clear Width
Technical requirements for walking
surfaces as part of an accessible route.
Technical requirements for clear width.
2. Storage areas . . .
11B-225.2 Storage
11B-223.3 Self-Service
Storage Facilities
Scoping requirements for general storage
uses.
Scoping for self-service storage facilities.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 19 of 106
Section 1105B Accessibility for Group B Occupancies 5 February 2013
Section 1106B Accessibility for Group E Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1106B.1 General.
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Exception 1.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1106B.2 Laboratory rooms. . . .
shall have at least one and at
least 5 percent of all
workstations accessible . . .
11B-226 Dining Surfaces and
Work Surfaces
11B-226.1 General
11B-226.2 Dispersion
11B-805.7 Built-in Cabinets
and Work Surfaces.
Exception 2.
11B-902 Dining Surfaces and
Work Surfaces
11B-902.1 General
11B-902.2 Clear Floor or
Ground Space
11B-902.3 Height
Scoping for number and dispersion of
work surfaces.
Detailed scoping for laboratory
workstations requiring 5 percent but not
less than one to be accessible.
Technical requirements for work surfaces.
Exception.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 20 of 106
Section 1106B Accessibility for Group E Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1106B.3 Teaching facility
cubicles, study carrels, etc.
11B-226 Dining Surfaces and
Work Surfaces
11B-226.1 General
11B-226.2 Dispersion
11B-902 Dining Surfaces and
Work Surfaces
11B-902.1 General
11B-902.2 Clear Floor or
Ground Space
11B-902.3 Height
Scoping for number and dispersion of
work surfaces.
Technical requirements for work surfaces.
1106B.4 Library general use
areas.
N/A
Title only in 2010 CBC.
1. General.
11B-201.1 Scope
11B-225.2 Storage
11B-227.3 Counters
General scoping for building and facility
accessibility
Scoping for storage.
Scoping for counters.
2. Open book stacks.
11B-225.2.3 Library Book
Stacks
Technical requirements for book shelves.
3. Height of book shelves.
11B-308.3 Side Reach
11B-308.3.1 Unobstructed,
Exception 3
Technical requirements for book shelves.
4. Card catalogs and
magazine displays.
11B-308.2 Forward Reach
11B-308.3 Side Reach
Technical requirements for reach ranges.
5. Reading and study areas.
11B-226 Dining Surfaces and
Work Surfaces
11B-226.1 General
11B-226.2 Dispersion
11B-902 Dining Surfaces and
Work Surfaces
11B-902.1 General
11B-902.2 Clear Floor or
Ground Space
11B-902.3 Height
Scoping for 5 percent of workstations to
comply with requirements.
Dispersion of work surfaces.
Technical requirements for work surfaces
6. Check-out areas.
11B-904.3.1 Check-Out Aisles
Technical requirements for check-out
aisles.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 21 of 106
Section 1106B Accessibility for Group E Occupancies 5 February 2013
Section 1107B Factories and Warehouses
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Factories and warehouses…..
11B-201 Application
11B-201.1 Scope
11B-206.2.3 Multi-Story
Buildings and Facilities
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in Multi-Story
Buildings and Facilities
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1107B.1 Factories.
N/A
Title only in 2010 CBC.
1. Major or principle floor
areas shall be made
accessible.
11B-201 Application
11B-201.1 Scope
11B-203.9 Employee Work
Areas
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.
2. Office areas shall be
made accessible.
11B-201 Application
11B-201.1 Scope
11B-203.9 Employee Work
Areas
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.
3. Sanitary facilities serving
these facilities . . .
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities.
1107B.2 Warehouses.
N/A
Title only in 2010 CBC.
1. Miscellaneous
warehousing areas . . .
11B-206.2.3 Multi-Story
Buildings and Facilities
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in Multi-Story
Buildings and Facilities
2. Office areas shall be
made accessible.
11B-203.9 Employee Work
Areas
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Scoping for accessible route in employee
work areas.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 22 of 106
Section 1107B Factories and Warehouses 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3. Sanitary facilities serving
these facilities . . .
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 23 of 106
Section 1107B Factories and Warehouses 5 February 2013
Section 1108B Accessibility for Group H Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1108B.1 General.
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1108B.2 Accessible sanitation
facilities.
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities.
1108B.3 Accessible routes.
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
1108B.4 Accessible floors and
levels.
11B-206.2.3 Multi-Story
Buildings and Facilities
11B-402 Accessible Routes
Scoping for accessible route in Multi-Story
Buildings and Facilities
Technical requirements for accessible
routes.
1108B.5 Employee work areas.
11B-203.9 Employee Work
Areas
Scoping for accessible route in employee
work areas.
1108B.6 Accessible facilities
covered . . .
11B-201 Application
11B-201.1 Scope
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 24 of 106
Section 1108B Accessibility for Group H Occupancies 5 February 2013
Section 1109B Accessibility for Group I Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1109B.1 General.
11B-223 Medical Care and
Long Term Care Facilities
Scoping for Medical Care and Long Term
Care Facilities
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1109B.2 Entrance.
11B-209 Medical and Long
Term Care Facilities
11B-503 Passenger Drop-Off
and Loading Zone
Scoping for accessible entrance with
passenger loading zone.
Technical requirements for passenger
drop-off and loading zones.
1109B.3 Patient bedrooms and
toilet rooms.
11B-223 Medical Care and
Long term Care Facilities
11B-805 Medical Care and
Long term Care Facilities
11B-805.2.4 Toilet and
Bathing Rooms
Scoping for patient bedrooms.
Technical requirements for patient
bedrooms.
Technical requirements for patient toilet
rooms.
1. Long-term care facilities . .
.
11B-223.3 Long Term Care
Facilities
Scoping for number of accessible rooms
in long term care facilities.
2. General purpose hospitals
. . .
11B-223.2.1 Facilities Not
Specializing in Treating
Conditions That Affect
Mobility.
Scoping for number of accessible rooms
in facilities not specializing in treating
conditions that affect mobility and general
hospital facilities.
3. Hospitals and
rehabilitation facilities that
specialize in treating
conditions affecting mobility .
. . .
11B-223.2.2 Facilities
Specializing in Treating
Conditions That Affect
Mobility
Scoping for number of accessible rooms
in facilities specializing in treating
conditions that affect mobility.
Exception 1.
11B-223.1.1.1 Area Alterations
Scoping for area alterations.
Exception 2.
11B-223.1.1.2 Individual
Alterations
Scoping for individual alterations.
1109B.4 Patient bedroom areas.
N/A
Title only in 2010 CBC.
1. Each bedroom shall have
a turning space . . .
11B-805.2.3 Turning Space
Technical requirements for turning space
in patient bedroom.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 25 of 106
Section 1109B Accessibility for Group I Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
2. Each bedroom shall have
a minimum clear floor space
. . .
11B-805.2.2 Beds
Technical requirements for clear space
along the full length of bed.
3. Each bedroom shall have
an accessible door . . .
11B-404.3 Manual Doors,
Doorways, and Gates
Technical requirements for doors,
doorways and gates.
1109B.5 Patient toilet rooms and
bathing facilities.
11B-805.2.4 Toilet and Bathing
Rooms
Technical requirements for patient toilet
rooms.
1109B.6 Diagnostic and
treatment areas.
11B-805.4 Examination,
Diagnostic and Treatment
Rooms.
Technical requirements for examination,
diagnostic and treatment rooms.
1109B.7 Waiting areas, offices
and sanitary facilities.
11B-213 Toilet and Bathing
Facilities
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for toilet and bathing facilities.
1109B.8 Offices and suites.
11B-201 Application
11B-201.1 Scope
11B-402 Accessible Routes
11B-203.9 Employee Work
Areas
11B-805.7 Built-in Cabinets
and Work Surfaces
Scoping for newly designed, newly
constructed and altered portions of
existing buildings.
Technical requirements for accessible
routes.
Scoping for accessible route in employee
work areas.
Technical requirements for built-in
cabinets and work surfaces.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 26 of 106
Section 1109B Accessibility for Group I Occupancies 5 February 2013
Section 1110B Accessibility for Group M Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1110B.1 Sales.
11B-227 Sales and Service
Scoping for sales and service facilities.
1110B.1.1 General areas.
11B-227 Sales and Service
11B-227.1 General
Scoping for sales and service facilities.
Exception 1
Not carried forward
This provision would lessen the level of
accessibility provided by the 2010 ADAS.
Exception 2
Not carried forward
This provision would lessen the level of
accessibility provided by the 2010 ADAS.
1110B.1.2 Work areas.
11B-227.2 Check-Out Aisles
11B-904 Check-Out Aisles
and Sales and Service
Counters
11B-203.9 Employee Work
Areas
Scoping for check-out aisles.
Technical requirements for check-out
aisles and sales and service counters.
Scoping for accessible route in employee
work areas.
1110B.1.3 Check stands.
11B-216.11 Check-Out Aisles
11B-227.2 Check-Out Aisles
11B-904.3 Check-Out Aisles
Table 11B-227.2 Check-Out
Aisles
Scoping for ISA at check-out aisle.
Scoping for check-out aisles.
Technical requirements for check-out
aisles.
Requirement for number of accessible
check-out aisles.
1110B.1.4 Point-of-sale
machines.
11B-220.2 Point-of-Sale
Devices
11B-707 Automatic Teller
Machine, and Fare Machines
and Point-of-Sale Devices
Scoping for point-of-sale devices.
Technical requirements for automatic
teller machine, and fare machines and
point-of-sale devices.
1110B.1.5 Turnstiles.
11B-404.2.1 Revolving Doors,
Gates, and Turnstiles.
Technical requirements for revolving
doors, gates, and turnstiles.
1110B.1.6 Theft prevention
barriers.
11B-206.8 Security Barriers
Scoping for security barriers.
1. Each entrance and exit . .
.
11B-206.4 Entrances
11B-207 Accessible Means of
Egress
Scoping for accessible entrances.
Scoping for accessible means of egress.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 27 of 106
Section 1110B Accessibility for Group M Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
2. Shopping cart barriers
located . . .
11B-206.8 Security Barriers
11B-404.2.4.2 Doorways
without Doors or Gates,
Sliding Doors, and Folding
Doors
Scoping for security barriers.
Technical requirements for doorways
without doors or gates, sliding doors, and
folding doors including openings.
3. Where gates are used . . .
11B-206.4 Entrances
11B-207 Accessible Means of
Egress
11B-404.2.4.2 Doorways
without Doors or Gates,
Sliding Doors, and Folding
Doors
Scoping for accessible entrances.
Scoping for accessible means of egress
Technical requirements for doorways
without doors or gates, sliding doors, and
folding doors including openings.
4. Where a clear
unobstructed opening . . .
Table 11B-404.2.4.1
Maneuvering Clearances at
Manual Swinging Doors and
Gates
Technical requirements for clearances at
manual swinging doors and gates.
5. Where a gate is used, the
level area . . .
Table 11B-404.2.4.1
Maneuvering Clearances at
Manual Swinging Doors and
Gates
Technical requirements for clearances at
manual swinging doors and gates.
6. Where a gate is used, the
bottom . . .
11B-404.2.10 Door and Gate
Surfaces.
Technical requirements for door and gate
surfaces.
7. The path of travel to and
through . . .
11B-307.5 Required Clear
Width
11B-403.5.1 Clear Width
Technical requirements for obstructions
within accessible route.
Technical requirements for clear width.
8. Interior and exterior traffic
barriers . . .
11B-307.5 Required Clear
Width
11B-403.5.1 Clear Width
Technical requirements for obstructions
within accessible route.
Technical requirements for clear width.
1110B.2 Miscellaneous general
standards.
N/A
Title only in 2010 CBC.
1110B.2.1 Circulation.
11B-225.2.2 Self-Service
Shelving
11B-403.5.1 Clear Width
Scoping for self-service shelving.
Technical requirements for clear width.
1110B.2.2 Storage areas.
11B-206.4 Entrances
11B-225 Storage
Scoping for accessible entrances.
Scoping for storage.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 28 of 106
Section 1110B Accessibility for Group M Occupancies 5 February 2013
Section 1111B Accessibility for Group R Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1111B.1 General.
11B-201.1, as excepted by 11B-
203.8
Scoping for residential facilities.
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1111B.2 Public and common use
rooms or areas.
11B-206 Accessible Routes
11B-402 Accessible Routes
11B-214 Washing Machines
and Clothes Dryers
11B-611 Washing Machines
and Clothes Dryers
Scoping for accessible routes.
Technical requirements for accessible
routes.
Scoping for washing machines and
clothes dryers.
Technical requirements for washing
machines and clothes dryers.
Exception: Where elevators
are not required . . .
11B-203.8 Residential
Facilities
11B-206.2.3 Multi-Story
Buildings and Facilities,
Exception 4.
Scoping for common use areas not on
accessible route.
Scoping for common use areas not on
accessible route in multi-story buildings.
1111B.3 Recreational facilities.
11B-206.2.2 Within a Site
11B-1001 General
Scoping for accessible routes within a
site.
Technical requirements for recreational
facilities including swimming pools.
1111B.4 Hotels, motels, inns,
dormitories, resorts, homeless
shelters, halfway houses,
transient group homes and
similar places of transient
lodging.
11B-224 Transient Lodging
Guest Rooms
11B-224.1.1 Alterations
Scoping for transient lodging
accommodations .
Scoping for alterations.
1111B.4.1 Available range of
accommodations.
11B-224.1.3 Range of
Accommodations
• 11B-224.5 Dispersion
Scoping for range of accommodations in
transient lodging facilities.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 29 of 106
Section 1111B Accessibility for Group R Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1111B.4.2 Guest rooms and
suites.
• 11B-224.2 Guest Rooms with
Mobility Features
• 11B-224.4 Guest rooms with
Communication Features
11B-806.2.4 Toilet and
Bathing Facilities
Scoping number of rooms with mobility
and communication features.
Technical requirements for toilet and
bathing facilities part of a guest room.
1111B.4.2.1 Spaces.
• 11B-201 Application
• 11B-201 Accessible Routes
Scoping for required accessible spaces
within a guest room.
1. The living area:
11B-806.2.1 Living and Dining
Areas
Technical requirements for living and
dining areas.
2. The dining area:
11B-806.2.1 Living and Dining
Areas
Technical requirements for living and
dining areas.
3. At least one sleeping
area:
11B-806.2.3 Sleeping Areas
Technical requirements for sleeping
areas.
4. Patios, terraces or
balconies:
11B-806.2.2 Exterior Spaces
Technical requirements for exterior space
including patios, terraces and balconies.
5. Where full bathrooms are
provided, at least . . .
11B-806.2.4 Toilet and Bathing
Facilitates
Technical requirements for toilet and
bathing facilities part of a guest room.
6. Where only half baths are
provided, at . . .
11B-806.2.4 Toilet and Bathing
Facilitates
Technical requirements for toilet and
bathing facilities part of a guest room.
7. Carports, Garages, or
Parking Spaces
11B-208 Parking
Scoping for parking.
1111B.4.2.2 Accessible route.
11B-206.4 Entrances
11B-806.2 Guest Rooms with
Mobility Features
Scoping for accessible entrances.
Technical requirement for accessible
feature.
1111B.4.2.3 Doors.
N/A
Title only in 2010 CBC.
1111B.4.2.3.1 Doors into and
within covered rooms and suites.
11B-206.4 Entrances
11B-206.5 Doors, Doorways
and Gates.
Scoping for accessible entrances.
1111B.4.2.3.2 Doors into and
within all other rooms and suites.
11B-224.1.2 Guest Room
Doors and Doorways
11B206.5.3 Transient Lodging
Facilities
Scoping for door and doorways in guest
rooms not required to have mobility
features.
1111B.4.2.4 Alterations in
existing facilities.
11B-224.1.1 Alterations
Scoping for alterations.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 30 of 106
Section 1111B Accessibility for Group R Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1111B.4.3 Access to beds.
• 11B-224.3 Beds
11B-806.2.3 Sleeping Areas
11B-806.2.3.1 Personal Lift
Device Floor Space
Scoping requirements for access to beds.
Technical requirements for access to
beds.
Technical requirements for personal lift
device floor space.
1111B.4.4 Kitchens, kitchenettes
or wet bar facilities.
11B-212 Kitchens,
Kitchenettes and Wet Bars.
11B-806.2.5 Kitchens,
Kitchenettes and Wet Bars.
Scoping for kitchens, kitchenettes and wet
bars.
Technical requirements for kitchens,
kitchenettes and wet bars.
1111B.4.5 Visible alarms,
notification devices and
telephones for persons with
hearing impairments.
• 11B224.4 Guest Rooms with
Communication Features
11B-806.3 Guest Rooms with
Communication Features
Scoping requirements for visible alarms,
notification devices and telephones.
Technical requirements for visible alarms,
notification devices and telephones.
1111B.4.5.1 Visible alarms.
11B-806.3.1 Alarms.
Technical requirements for alarms.
1111B.4.5.2 Visual notification
devices.
11B-806.3.2 Notification
Devices
Technical requirements for notification
devices.
1111B.4.5.3 Telephones.
11B-806.3.2 Notification
Devices
Technical requirements for notification
devices including telephones.
1111B.4.6 Bathrooms in hotels,
motels, inns, dormitories,
resorts, homeless shelters,
halfway houses, transient
group homes and similar places
of transient lodging.
11B-806.2.4.
Technical requirements for toilet and
bathing facilities.
1. Doors.
11B-603.2.3 Door Swing
Technical requirements for door swing
into toilet room.
2. Clear floor space.
11B-603.2.1 Turning Space
Technical Requirements for turning space
within the toilet and bathing facility.
3. Water closets.
11B-604.3 Clearance
Technical requirements for clearance
around water closets.
4. Lavatory and mirrors.
11B-606 Lavatories and Sinks
11B-603.3 Mirrors
Technical requirements for lavatories and
sinks.
Technical requirements for mirrors.
5. Controls and dispensers.
11B-309 Operable Parts
11B-603.5 Accessories
Technical requirements for operable parts
Technical requirements for accessories
Cross Reference Guide - 2010 CBC to 2013 CBC Page 31 of 106
Section 1111B Accessibility for Group R Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
6. Bathing and shower
facilities.
11B-607 Bathtubs
11B-608 Shower
Compartments
11B-806.2.4 Toilet and
Bathing Facilities
Technical requirements for bathtubs and
shower compartments
7. Toilet facilities.
11B-603 Toilet and Bathing
Rooms
11B-604 Water Closets and
Toilet Compartments
11B-806.2.4 Toilet and
Bathing Facilities
Technical requirements for toilet rooms
Hotel and motel bathrooms
beyond those specified in
Section 1111B.4 shall
provide the following
features:
1. All bathroom fixtures shall
be in a location that allows a
person using a wheelchair
measuring 30 inches by 48
inches (762 mm by 1219
mm) to touch the wheelchair
to any lavatory, urinal, water
closet, tub, sauna, shower
stall and any other similar
sanitary installation, if
provided.
2. All bathroom entrance
doors shall have a clear
opening width of 32 inches
(813 mm) and shall be either
sliding doors or shall be
hung to swing in the
direction of egress from the
bathroom.
11B-224.1.6 Guest Room
Toilet and Bathing Rooms
11B-213.2 Toilet Rooms and
Bathing Rooms
• 11B-603.6 Guest Room Toilet
and Bathing Rooms
11B-224.1.2 Guest Room Doors
and Doorways
Scoping for toilet and bathing rooms in
guest rooms not required to provide
mobility features.
Technical requirements for toilet and
bathing rooms in guest rooms not
required to provide mobility features.
Technical requirements for clear width at
door for guest rooms not required to have
mobility features.
1111B.4.7 Storage areas.
11B-224.6 Storage
Scoping for fixed or built-in storage
1111B.4.8 Dormitory rooms.
11B-224.1.2 Guest Room Doors
and Doorways
Technical requirements for clear width at
door for guest rooms not required to have
mobility features. Adaptable feature
language not carried forward, those
features are in kitchens and bathrooms,
not located in dorm room.
1111B.5 Buildings and
complexes containing publicly
funded dwelling units.
N/A
Title only in 2010 CBC
Cross Reference Guide - 2010 CBC to 2013 CBC Page 32 of 106
Section 1111B Accessibility for Group R Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1111B.5.1 General.
• 11B-233 Residential Facilities
• 11B-233.3.4 Alterations
Scoping for publicly funded facilities
containing residential dwelling units
Cross Reference Guide - 2010 CBC to 2013 CBC Page 33 of 106
Section 1111B Accessibility for Group R Occupancies 5 February 2013
Section 1112B Reserved
Section 1113B Reserved
Cross Reference Guide - 2010 CBC to 2013 CBC Page 34 of 106
Section 1112B & Section 1113B Reserved 5 February 2013
Section 1114B Facility Accessibility
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1114B.1 Design and
construction.
11B-201.1 Scope
General scoping for building and facility
accessibility
1114B.1.1 General.
11B-201.1 Scope
General scoping for building and facility
accessibility
Chapter 11B, Accessibility
11B-201.1 Scope
General scoping for building and facility
accessibility
Entrances
11B-206.4 Entrances
General scoping for building and facility
accessibility
Doors
11B-206.5 Doors, Doorways
and Gates
General scoping for building and facility
accessibility
Corridors
11B-206 Accessible Routes
General scoping for building and facility
accessibility
Stairways
11B-210 Stairways
General scoping for building and facility
accessibility
Ramps
11B-206 Accessible Routes
General scoping for building and facility
accessibility
Aisles
11B-206 Accessible Routes
General scoping for building and facility
accessibility
Walks and Sidewalks
11B-206 Accessible Routes
General scoping for building and facility
accessibility
Hazards
11B-206 Accessible Routes
General scoping for building and facility
accessibility
Elevators
11B-206.6 Elevators
General scoping for building and facility
accessibility
Platform (Wheelchair) Lifts
11B-206.7 Platform Lifts
General scoping for building and facility
accessibility
Alarms
11B-215 Fire Alarm Systems
General scoping for building and facility
accessibility
Bathing and Toilet Facilities
11B-213 Toilet Facilities and
Bathing Facilities
General scoping for building and facility
accessibility
Signs and Identification
11B-216 Signs
General scoping for building and facility
accessibility
Detectable Warnings
11B-705 Detectable Warnings
General scoping and technical
requirements for building and facility
accessibility detectable warning
Cross Reference Guide - 2010 CBC to 2013 CBC Page 35 of 106
Section 1114B Facility Accessibility 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Other Building Components
11B-205 Operable Parts
11B-211 Drinking Fountains
11B-212 Kitchens,
Kitchenettes and Sinks
• 11B-217 Telephones
• 11B-220 Automatic Teller
Machines and Fare Machines
11B-222 Dressing, Fitting and
Locker Rooms
General scoping for building and facility
accessibility
1114B.1.2 Accessible route of
travel.
11B-206 Accessible Routes
11B-402 Accessible Routes
Scoping and technical requirements for
accessible routes
Exception: Where an
elevator is provided . . .
11B-206.6 Elevators
Scoping for elevators where more than
one elevator is provided, all elevators
shall be accessible
1114B.1.3 Primary entry access.
11B-206.4 Entrances
11B-206.5.5 Exterior Ground
Floor Exit Doors
Scoping for entrances and exterior ground
floor exit doors
1114B.1.4 Signs.
11B-216 Signs
Scoping for signs
1114B.1.5 Adaptable dwelling
units.
11B-206.4.6 Residential
Dwelling Unit Primary
Entrance
Scoping for primary entrances at
residential dwelling units
1114B.2 Egress and areas of
refuge.
11B-207 Accessible Means of
Egress
Scoping for accessible means of egress
1114B.2.1 General.
11B-207 Accessible Means of
Egress
Scoping for accessible means of egress
reference to Chapter 10, Section 1007
1114B.2.2 Alarms/emergency
warning systems/accessibility.
11B-215 Fire Alarm Systems
Scoping for fire alarm systems
subsection references to Chapter 9,
Sections 907.5.2.1 and 907.5.2.3
Cross Reference Guide - 2010 CBC to 2013 CBC Page 36 of 106
Section 1114B Facility Accessibility 5 February 2013
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities)
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1115B.1 General.
11B-213.2 Toilet Rooms and
Bathing Rooms
11B-603.2 Clearances
General scoping and clearance
requirements for toilet and bathing
facilities
Exception: In existing
buildings and facilities . . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1115B.1.1 Separate and unisex
facilities.
11B-213.2 Toilet Rooms and
Bathing Rooms
General scoping for toilet and bathing
facilities
1115B.1.2 Where used by
children.
11B-604.9 Water Closets and
Toilet Compartments for
Children’s Use
General scoping for toilet and bathing
facilities used by children
1115B.2 Bathing and shower
facilities.
11B-213.3.6 Bathing
Facilities
General scoping for bathing facilities
1115B.3 Toilet facilities.
11B-604.1 General
Technical requirements for toilet facilities
1115B.3.1 Multiple-
accommodation toilet facilities.
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for multiple-accommodation toilet
facilities
1. Wheelchair clearance.
11B-603.2 Clearances
Technical requirements for turning space
2. Clear floor space at
fixtures.
11B-603.2 Clearances
Technical requirements for overlap and
door swing
3. Accessible fixtures.
11B-213.3.2 Water Closets
11B-213.3.4 Lavatories
Scoping for water closets and lavatories
4. Accessible water closet
compartment.
11B-604.8.1 Toilet
Compartments
Technical requirements for accessible
compartment within multiple-
accommodation toilet facilities
4.1. The compartment
shall be . . . 60 inches
wide.
11B-604.8.1.1 Size
Technical requirement for width of
compartment
4.2. If the compartment
has a side-opening door
. . .
11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door
11B-604.8.1.1.2 Maneuvering
Space with Side-Opening
Door
Technical requirement for maneuvering
space in front of water closet in a
compartment with a side-opening door
Cross Reference Guide - 2010 CBC to 2013 CBC Page 37 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
4.3. If the compartment
has an end-opening
door . . .
11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door
11B-604.8.1.1.3 Maneuvering
Space with End-Opening
Door
Technical requirement for maneuvering
space in front of water closet in a
compartment with an end-opening door
4.4. The water closet
compartment shall . . .
11B-604.8.1.2 Doors
11B-604.8.1.2 Exception
Technical requirements for doors
Model code amended to add technical
requirement for 34” clear at in-swinging
side-opening doors
4.5.The inside and
outside of the
compartment door . . .
11B-604.8.1.2 Doors
Technical requirements for doors
5. Large toilet rooms.
11B-213.3.1 Toilet
Compartments
11B-604.8.2 Ambulatory
Accessible Compartments
Scoping and technical requirements for
ambulatory accessible compartments
within multiple-accommodation toilet
facilities
6. Interior surfaces.
11B-302 Floor or Ground
Surfaces
Technical requirement for floors within
toilet facilities
1115B.3.2 Single-
accommodation toilet facilities.
11B-213.2 Toilet Rooms and
Bathing Rooms
Scoping for single-accommodation toilet
facilities
1. Wheelchair clearance.
11B-603.2 Clearances
Technical requirements for turning space
2. Clear floor space at
fixtures.
11B-603.2 Clearances
Technical requirements for overlap and
door swing
3. Accessible water closet.
11B-213.3.2 Water Closets
11B-604.3.1 Size
Scoping and technical requirements for
water closets
4. Accessible route.
11B-213.2 Toilet Rooms and
Bathing Rooms
11B-603.2 Clearances
Scoping and technical requirement for
accessible route
5. Interior surfaces.
11B-302 Floor or Ground
Surfaces
Technical requirement for floors within
toilet facilities
6. Accessible lavatory.
11B-213.3.4 Lavatories
Scoping requirement for lavatory
7. Privacy latch.
11B-213.2.1 Unisex (Single-Use
or Family) Toilet and Unisex
Bathing Rooms
Scoping requirement for privacy latch
Cross Reference Guide - 2010 CBC to 2013 CBC Page 38 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Exception: In an existing
building, a single-
accommodation toilet
facility . . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1115B.4 Accessible fixtures.
11B-213.3 Plumbing Fixtures
and Accessories
General scoping for accessible toilet and
bathing facilities fixtures
1115B.4.1 Accessible water
closets.
11B-213.3.2 Water Closets
General scoping for water closets
1. The centerline of the
water closet . . .
11B-604.2 Location
11B-604.3 Clearance
Technical requirements for centerline and
clearances at water closets
2. Provide clear floor
space . . .
11B-604.3 Clearance
Technical requirements for clearances at
water closets
2.1. Where a water
closet is not within a
water closet
compartment . . .
11B-604.3.1 Size
Technical requirements for size of
clearance at water closets not located
within accessible compartments
2.2. Where a wall
mounted water closet is
installed within . . .
11B-604.8.1.1 Size
Technical requirements for size of
clearance at water closets located within
accessible compartments
2.3. Where a water
closet is installed within
an accessible . . .
11B-604.8.1.1.1 Maneuvering
Space with In-Swinging Door
Technical requirements for maneuvering
space at compartments with in-swinging
doors
Exception: An
adjacent fixture at
the rear wall . . .
11B-604.3.2 Overlap Exception
Exception for adjacent fixture at the rear
wall applicable in residential dwelling units
only
3. Grab bars for . . .
11B-604.5 Grab Bars
11B-604.8.1.5 Grab Bars
11B-604.8.2.3 Grab Bars
Scoping for grab bars in accessible
compartments and ambulatory accessible
compartments.
3.1. Side wall
11B-604.5.1 Side Wall
Technical requirements for side wall grab
bars
3.2. Rear wall
11B-604.5.2 Rear Wall
Technical requirements for rear wall grab
bars
4. The height of accessible
water closets . . .
11B-604.4 Seats
Technical requirements for toilet seats
Exception: A 3-inch high
seat . . .
11B-604.4 Exception
Exception permitted only in alterations
Cross Reference Guide - 2010 CBC to 2013 CBC Page 39 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
5. Controls shall be
operable . . .
11B-604.6 Flush Controls
Technical requirements for flush controls
6. See Section 1134A.7 for
additional requirements . . .
N/A
Requirements for residential dwelling
units located in 2013 CBC, Chapter 11B
7. Automatic springs to lifted
position . . .
N/A
Not addressed by 2010 ADAS
1115B.4.2 Accessible urinals.
11B-213.3.3 Urinals
General scoping for urinals
1. Urinals shall be . . .
11B-605.2 Height and Depth
Technical requirements for urinal height
and depth
2. Flush controls . . .
11B-605.4 Flush Controls
Technical requirements for flush controls
at urinals
3. Where urinals are
provided . . .
11B-605.3 Clear Floor Space
Technical requirement for clear floor
space at urinals
1115B.4.3 Accessible lavatories.
11B-213.3.4 Lavatories
General scoping for lavatories
1. Faucet controls and . . .
11B-606.4 Faucets
Technical requirements for controls for
faucets
2. Lavatories, when located
adjacent to . . .
11B-606.2 Clear Floor Space
11B-606.3 Height
11B-606.6 Adjacent Side Wall
or Partition
Technical requirements for height,
location and toe and knee clearance
3. A clear floor space 30
inches . . .
11B-306 Knee and Toe
Clearance
11B-606.2 Clear Floor Space
Technical requirements for toe and knee
clearance and clear floor space
4. Hot water and drain pipes
. . .
11B-606.5 Exposed Pipes and
Surfaces
Technical requirements for exposed pipes
and surfaces beneath lavatories
1115B.4.4 Accessible showers.
11B-213.3.6 Bathing Facilities
General scoping for showers
1115B.4.4.1 Size and
clearances.
11B-608.2 Size and Clearances
for Shower Compartments
General scoping for shower
compartments
1. Roll-in shower . . .
11B-608.2.2 Standard Roll-In
Type Shower Compartment
Technical requirements for standard roll-
in type shower compartments
2. Alternate roll-in shower 60
inches minimum in width . . .
11B-608.2.3 Alternate Roll-In
Type Shower Compartment
Technical requirements for alternate roll-
in type shower compartments
3. Alternate roll-in shower
with optional enclosure . . .
11B-608.2.3 Alternate Roll-In
Type Shower Compartment
11B-608.8 Shower
Enclosures
Technical requirements for alternate roll-
in type shower compartments applicable
Cross Reference Guide - 2010 CBC to 2013 CBC Page 40 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1115B.4.4.2 Thresholds.
11B-608.7 Thresholds
Technical requirements for thresholds
1115B.4.4.3 Orientation.
11B-213.3.6 Bathing Facilities
Scoping requirement for orientation
1115B.4.4.4 Water controls.
11B-608.5 Controls
Technical requirements for controls
1. Controls in a . . . roll-in
shower . . .
11B-608.5.2 Standard Roll-In
Type Shower Compartments
Technical requirements for controls in
standard roll-in type shower
compartments
2. Controls in an . . .
alternate roll-in shower . . .
11B-608.5.3 Alternate Roll-In
Type Shower Compartments
Technical requirements for controls in
alternate roll-in type shower
compartments
3. Controls in an . . .
alternate roll-in shower . . .
with optional enclosure . . .
11B-608.5.3 Alternate Roll-In
Type Shower Compartments
Technical requirements for controls in
alternate roll-in type shower
compartments applicable
1115B.4.4.5 Hand-held sprayer
unit.
11B-608.6 Shower Spray Unit
and Water
1. The hand-held sprayer
unit . . .
11B-608.5.2 Standard Roll-In
Type Shower Compartments
Technical requirements for shower sprays
in standard roll-in type shower
compartments
2. The hand-held sprayer
unit . . . in an . . . alternate
roll-in shower . . .
11B-608.5.3 Alternate Roll-In
Type Shower Compartments
Technical requirements for shower sprays
in alternate roll-in type shower
compartments
3. The hand-held sprayer
unit . . . in an . . . alternate
roll-in shower . . . with
optional enclosure . . .
11B-608.5.3 Alternate Roll-In
Type Shower Compartments
Technical requirements for shower sprays
in alternate roll-in type shower
compartments applicable
1115B.4.4.6 Sprayer unit
alternative.
11B-608.6 Exception
Exception permitted in areas subject to
excessive vandalism only
1115B.4.4.7 Floor slope.
11B-608.9 Shower Floor or
Ground Surface
Technical requirements for shower floor
surface
1115B.4.4.8 Shower
accessories.
11B-608.1 General
General scoping for showers
1. A folding seat . . .
11B-608.4 Seats
11B-610.3 Shower
Compartment Seats
Technical requirements for seats
2. Grab bars located on
walls . . .
11B-608.3 Grab Bars
Technical requirements for grab bars
1115B.4.4.9 Soap dish.
11B-608.10 Soap Dish
Technical requirements for soap dishes
1115B.4.4.10 Enclosures.
11B-608.8 Shower Enclosures
Technical requirements of enclosures
Cross Reference Guide - 2010 CBC to 2013 CBC Page 41 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1115B.4.5 Accessible bathtubs.
11B-213.3.6 Bathing Facilities
General scoping for bathtubs
1. Floor space.
11B-607.2 Clearance
Technical requirements for clearances at
bathtubs
2. Seat.
11B-607.3 Seat
11B-610.2 Bathtub Seats
Technical requirements for seats
3. Grab bars.
11B-607.4 Grab Bars
Technical requirements for grab bars
4. Controls.
11B-607.5 Controls
Technical requirements for controls
5. Shower unit.
11B-607.6 Shower Spray Unit
and Water
Technical requirements for shower spray
units.
6. Bathtub enclosures.
11B-607.7 Bathtub Enclosures
Technical requirements for enclosures
1115B.5 Passageways.
11B-603.2.3 Door Swing
11B-604.8.1.2 Doors
Technical requirements for doors and
door swings
1115B.6 Identification symbols.
11B-216.8 Toilet Rooms and
Bathing Rooms
11B-703.7.2.6 Toilet and
Bathing Facilities Geometric
Symbols
Scoping and technical requirements for
geometric identification symbols at toilet
and bathing rooms
1115B.6.1 Men’s sanitary
facilities . . .
11B-703.7.2.6.1 Men’s Toilet
and Bathing Facilities
Technical requirements for geometric
identification symbols
1115B.6.2 Woman’s sanitary
facilities . . .
11B-703.7.2.6.2 Women’s Toilet
and Bathing Facilities
Technical requirements for geometric
identification symbols
1115B.6.3 Unisex sanitary
facilities . . .
11B-703.7.2.6.3 Unisex Toilet
and Bathing Facilities
Technical requirements for geometric
identification symbols
1115B.7 Grab bars, tub and
shower seats.
11B-609.1 General
11B-610.1 General
General scoping for grab bars & seats
1115B.7.1 Diameter or width.
11B-609.2 Cross Section
11B-609.3 Spacing
Technical requirements for grab bar size
and mounting distance from wall
1115B.7.2 Structural strength.
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
1. Bending stress . . .
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
2. Shear stress . . .
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
Cross Reference Guide - 2010 CBC to 2013 CBC Page 42 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3. Shear force induced . . .
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
4. Tensile force induced . . .
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
5. Grab bars shall not rotate
within their fittings.
11B-609.8 Structural Strength
11B-610.4 Structural Strength
Technical requirements for the structural
strength of grab bars, seats, fasteners,
mounting devices or supporting structures
1115B.7.3 Surface.
11B-609.5 Surface Hazards
Technical requirements for the surface of
grab bars
1115B.8 Accessories.
11B-603.5 Accessories
Technical requirements for accessories
1115B.8.1 Mirrors.
11B-213.3.5 Mirrors
Scoping for mirrors in toilet and bathing
facilities
1115B.8.1.1. All mirrors located
above accessible lavatories . . .
11B-603.3 Mirrors
Technical requirements for mirrors
1115B.8.1.2. When mirrors are
provided other than above
lavatories . . .
11B-603.3 Mirrors
Technical requirements for mirrors
1115B.8.1.3
11B-222.3 Mirrors
General scoping for mirrors in fitting and
dressing rooms
1115B.8.2 Medicine cabinets.
11B-225.2 Storage
11B-603.4 Coat Hooks,
Shelves and Medicine
Cabinets
General scoping and technical
requirement for coat hooks, shelves and
medicine cabinets
1115B.8.3 Towel, sanitary
napkins, waste receptacles,
dispensers and controls.
11B-603.5 Accessories
Technical requirements for accessories
1115B.8.4 Toilet tissue
dispensers.
11B-604.7 Dispensers
Technical requirements for toilet paper
dispensers
1115B.8.5 Lockers.
11B-225.2.1 Lockers
11B-811 Storage
General scoping and technical
requirements for lockers
Cross Reference Guide - 2010 CBC to 2013 CBC Page 43 of 106
Section 1115B Bathing and Toilet Facilities (Sanitary Facilities) 5 February 2013
Section 1116B Elevators and Platform (Wheelchair) Lifts
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1116B.1 Elevators.
11B-206.6 Elevators
11B-407.1 General
11B-407.1.1 Combined
Passenger and Freight
Elevators
Chapter 35 Referenced Standards
ASME A17.1
Scoping for Elevators
Technical requirements for combined
passenger and freight elevators.
1116B.1.1 General.
N/A
Title only in 2010 CBC.
Exception 1. In existing
buildings . . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2. In existing
buildings . . . the minimum
car plan dimension . . .
11B-407.4.1 Car Dimensions.
Exception.
In existing buildings, where existing shaft
configuration or technical infeasibility
prohibits strict compliance with 11B-
407.4.1, existing elevator car
configurations that provide a clear floor
area of 18 square feet (1.67 m2)
minimum and also provide an inside clear
depth 54 inches (1372 mm) minimum and
a clear width 48 inches (1219 mm)
minimum shall be permitted.
Exception 3. In existing
buildings equivalent
facilitation . . .
11B-103 Equivalent Facilitation
General provision for equivalent
facilitation is available; no need for
specific exception.
Exception 4. These
provisions shall not apply . . .
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1116B.1.2 Operation and
leveling.
11B-407.1 General.
11B-407.4.3 Platform to
Hoistway Clearance.
11B-407.4.4 Leveling.
Technical requirements for automatic
operation, clearance and leveling.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 44 of 106
Section 1116B Elevators and Platform (Wheelchair) Lifts 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1116B.1.3 Door operation.
11B-407.3.1 Type.
11B-407.3.2 Operation.
Technical requirements for door operation
1116B.1.4 Door size.
11B-407.4.1 Elevator Car
Dimensions
Technical requirements for elevator car
and door dimensions
1116B.1.5 Door protective and
reopening device
11B-407.3.3 Reopening
Device
11B-407.3.3.1 Height
11B-407.3.3.2 Contact
11B-407.3.3.3 Duration
Technical requirements for reopening
device.
1116B.1.6 Hall call.
11B-407.3.4 Door and Signal
Timing
Technical requirements for door and
signal timing.
1116B.1.7 Car
11B-407.3.5 Door Delay
Technical requirement for door delay.
1116B.1.8 Car inside.
11B-407.4.1 Car Dimensions.
11B-407.4.2 Floor Surfaces.
11B-407.4.6.1 Location
11B-407.4.6.4 Emergency
Controls
11B-407.4.7.1.4 Visible
Indicators
11B-407.4.9 Emergency
Communications
11B-408.4.6 Location
11B-409.4.6.2 Location
Technical requirements for elevator car
dimensions.
Technical requirements for floor surfaces.
Technical requirements for reach range
Technical requirements for emergency
controls
Technical requirements for visible
indicators.
Technical requirements for emergency
communications
Technical requirements for location of
control panels.
1116B.1.9 Car controls.
11B-407.4.6.2 Buttons
11B-407.4.6.2.1 Size and
Shape
11B-407.4.6.2.3 Illumination
11B-407.4.6.2.4 Operation
11B-407.4.7.1.1 Type
11B-407.4.7.1.2 Location
11B-407.4.7.1.3 Symbols
11B-407.4.8.1 Visible
Indicators
11B-407.4.8.2 Audible
Indicators
Technical requirements for control
buttons.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 45 of 106
Section 1116B Elevators and Platform (Wheelchair) Lifts 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1116B.1.10 Hall call buttons.
11B-407.2.1.1 Height
11B-407.2.1.2 Size and
Shape
11B-407.2.1.3 Clear Floor or
Ground Space
11B-407.2.1.4 Location
11B-407.4.8.2 Audible
Indicators
Technical requirements for hall call
buttons
1116B.1.11 Handrails.
11B-407.4.10 Support Rail
Technical requirements for support rail.
1116B.1.12 Minimum
illumination.
11B-407.4.5 Illumination
Technical requirements for illumination at
car, threshold and landing.
1116B.1.13 Hall lantern.
11B-407.2.2.1 Visible and
Audible Signals
11B-407.2.2.2 Visible Signals
11B-407.2.2.3 Audible
Signals
Technical requirements for visible and
audible signals.
1116B.1.14 Doorjamb marking.
11B-407.2.3.1 Floor
Designation
Technical requirements for door jamb
markings
1116B.1.15 Location.
11B-402.2 Components
11B-108 Maintenance of
Accessible Features
Scoping for elevators
1116B.2 Platform (wheelchair)
lifts.
11B-206.7 Platforms Lifts
Scoping for platform lifts
1.
11B-206.7.1 Performance
Areas and Speakers’
Platforms
Scoping for platform lifts
2.
11B-206.7.2 Wheelchair
Spaces
Scoping for platform lifts
3.
11B-206.7.3 Incidental Spaces
Scoping for platform lifts
4.
11B-206.7.5 Existing Site
Constraints
Scoping for platform lifts
Exception
11B-206.7 Platform Lifts
Scoping for platform lifts.
1116B.2.1 General.
11B-410.1 General
Technical requirements for compliance
with ASME A18.1
1116B.2.2 Unassisted entry.
11B-410.1 General
Technical requirements for unassisted
entry
1116B.2.3 Landing size.
11B-410.7 Landing Size
Technical requirements for landing size
Cross Reference Guide - 2010 CBC to 2013 CBC Page 46 of 106
Section 1116B Elevators and Platform (Wheelchair) Lifts 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1116B.2.4 Relationship to the
path of travel.
11B-402.2 Components
Location on accessible route
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1116B.2.5 When provided as a
means of egress.
11B-207.1 General
Scoping for platform lifts as a means of
egress.
1116B.2.5.1 Standby power.
11B-207.2 Platforms Lifts
Scoping for standby power at platform
lifts.
1116B.2.5.2
11B-206.7.2 Wheelchair
Spaces
Scoping for platform lifts, used to comply
with line-of-sight and dispersion
requirements.
1116B.2.6 Doors and gates.
11B-410.6 Doors and Gates
Technical requirements for doors and
gates at platform lifts.
Exception
11B-410.6 Doors and Gates,
Exception
Technical requirements for doors and
gates at platform lifts.
1116B.2.7 Restriction sign.
11B-410.8 Restriction Sign
Technical requirements for restriction
sign.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 47 of 106
Section 1116B Elevators and Platform (Wheelchair) Lifts 5 February 2013
Section 1117B Other Building Components
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1117B.1 Accessible drinking
fountains.
11B-211.1 General
General scoping for drinking fountains.
1. General.
11B-211.2 Minimum Number
11B-211.3 More Than
Minimum Number
General scoping for drinking fountains.
2. Clearances.
11B-306 Knee and Toe
Clearance
11B-602.2 Clear Floor Space
11B-602.8 Depth
Technical requirements for clear floor
space, knee and toe clearance, and
depth.
3. Alcoves.
11B-602.9 Pedestrian
Protection
Technical requirements for pedestrian
protection alcoves or wing walls.
4.
11B-602.4 Spout Height
11B-602.5 Spout Location
Technical requirements for spout location
and height.
5.
11B-602.6 Water Flow
Technical requirement for water flow.
1117B.2 Telephones.
11B-217.1 General
General scoping for public telephones
1117B.2.1 General.
11B-217.2 Wheelchair
Accessible Telephones
General scoping for wheelchair
accessible telephones
1117B.2.2 Clear floor or ground
space.
11B-704.2.1 Clear Floor or
Ground Space
Technical requirements for clear floor or
ground space
1117B.2.3 Size and approach.
11B-704.2.1.1 Parallel
Approach
11B-704.2.1.2 Forward
Approach
Technical requirements for parallel or
forward approach
1117B.2.4 Relationship of
maneuvering clearances to
wheelchair spaces.
11B-704.2.1 Clear Floor or
Ground Space
11B-305.6 Approach
Technical requirements for clear floor
space and approach
1117B.2.5 Floor surfaces of
wheelchair spaces.
11B-704.2.1 Clear Floor or
Ground Space
11B-302.1 General
Technical requirements for floor surfaces
1117B.2.6 Mounting height.
11B-704.2.2. Operable Parts
11B-309 Operable Parts
Technical requirements for mounting
height of operable parts
1117B.2.7 Enclosures.
11B-704.2.1 Clear Floor or
Ground Space
Technical requirements for clear floor
space at an enclosure
1. Side reach possible.
11B-704.2.1.1 Parallel
Approach
Technical requirements for parallel
approach at a telephone within an
enclosure
2. Full-height enclosures.
11B-704.2.1.2 Forward
Approach
Technical requirements for forward
approach at a telephone within an
enclosure
Cross Reference Guide - 2010 CBC to 2013 CBC Page 48 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3. Forward reach required.
11B-704.2.1.2 Forward
Approach
Technical requirements for forward
approach at a telephone within an
enclosure
4. Protruding telephone
enclosures.
11B-307 Protruding Objects
Technical requirements for protruding
objects
1117B.2.8 Telephone equipment
for hearing impaired persons.
11B-704.3 Volume Control
Telephones
Technical requirements for public
telephones required to have volume
controls
1117B.2.9 Text telephones.
11B-217.4 TTYs
General scoping for TTYs
1117B.2.9.1 Where required.
11B-217.4.1 Bank
Requirement
11B-217.4.2 Floor
Requirement
General scoping for the number of TTYs
required in specific locations
1.
11B-217.4.1 Bank
Requirement
11B-217.4.2 Floor
Requirement
General scoping for the number of TTYs
required in specific locations
2.
11B-217.4.3.1 Public
Buildings
11B-217.4.4 Exterior Site
Requirements
General scoping for the number of TTYs
required in specific locations
3.
11B-217.4.6 Hospitals
General scoping for the number of TTYs
required in specific locations
4.
11B-217.4.3.2 Private
Buildings
11B-217.4.4 Exterior Site
Requirements
General scoping for the number of TTYs
required in specific locations
5.
11B-217.4.3.2 Private
Buildings
11B-217.4.4 Exterior Site
Requirements
General scoping for the number of TTYs
required in specific locations
1117B.2.9.2 General.
11B-704.4 TTYs
Technical requirements for TTYs
1.
11B-704.4 TTYs
Technical requirements for TTYs
2.
11B-217.5 Shelves for
Portable TTYs
11B-704.5 TTY Shelf
Scoping for shelves for portable TTYs
3.
11B-103 Equivalent Facilitation
General provision for the use of products
providing equivalent facilitation
1117B.2.9.3 Signage.
11B-219 TTYs
Scoping for signs required for TTYs
1117B.2.10 Controls.
11B-704.2.2 Operable Parts
Technical requirements for operable parts
Cross Reference Guide - 2010 CBC to 2013 CBC Page 49 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1117B.2.11 Cord length.
11B-704.2.4 Cord Length
Technical requirements for cord length
1117B.2.12 Telephone books.
11B-704.2.3 Telephone
Directories
Technical requirements for telephone
directories
1117B.3 Kitchens.
11B-233 Residential
Facilities
11B-804 Kitchens &
Kitchenettes
Scoping for Residential Facilities
Technical requirements for kitchens &
kitchenettes
1117B.4 Swimming pools.
11B-242 Swimming Pools,
Wading Pools, and Spas
11B-1009 Swimming Pools,
Wading Pools, and Spas
Scoping for swimming pools, wading
pools, and spas.
Technical requirements for swimming
pools, wading pools, and spas.
1117B.5 Signs and identification.
11B-703 Signs
Obsolete advisory reference to Section
4.30 of the 1991 Standards not carried
forward
1117B.5.1 General.
11B-216.1 General
11B-703.1 General
General scoping and technical
requirements for signs
1. Identification signs.
11B-216.2 Designations
11B-703.2 Raised Characters
11B-703.3 Braille
Scoping and technical requirements for
interior and exterior signs identifying
permanent room and spaces
2. Directional and
informational signs.
11B-216.3 Directional and
Informational Signs
11B-703.5 Visual Characters
Scoping and technical requirements for
signs that provide directions to or
information about facilities
3. Accessibility signs.
11B-703.7 Symbols of
Accessibility
Scoping and technical requirements for
symbols of accessibility
4. Plan review and inspection.
11B-703.1.1 Plan Review and
Inspection
Plan review and inspection requirements
4.1. Plan review.
11B-703.1.1.1 Plan Review
Plan review and inspection requirements
4.2. Inspection.
11B-703.1.1.2 Inspection
Plan review and inspection requirements
4.3. Other signs and
identification.
11B-703.1.1 Plan Review and
Inspection
Plan review and inspection requirements
1117B.5.2 Finish and contrast.
11B-703.5.1 Finish and
Contrast
11B-703.6.2 Finish and
Contrast
11B-703.7.1 Finish and
Contrast
Technical requirements for non-glare
finish on visual signs, including
pictograms and symbols of accessibility
1117B.5.3 Proportions.
11B-703.2.4 Character
Proportions
11B-703.2.6 Stroke Thickness
Technical requirements for characters on
tactile signs
Cross Reference Guide - 2010 CBC to 2013 CBC Page 50 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1117B.5.4 Character height.
11B-703.5.4 Character
proportions
11B-703.5.5 Character Height
Technical requirements for characters on
visual signs
1117B.5.5 Raised characters
and pictorial symbol signs.
11B-703.2 Raised Characters
11B-703.6 Pictograms
Technical requirements for raised
characters and pictograms
1. Character type.
11B-703.2.1 Depth
11B-703.2.2 Case
11B-703.2.3 Style
Technical requirements for depth, case &
style of raised characters
2. Character size.
11B-703.2.5 Character Height
Technical requirements for height of
raised characters
3. Pictorial symbol signs
(pictograms).
11B-703.6.1 Pictogram Field
11B-703.6.3 Text Descriptors
Technical requirements for pictograms
4. Character placement.
11B-703.2.9 Format
11B-703.3.2 Position
Technical requirements for horizontal
format and Braille position
1117B.5.6 Braille.
11B-703.3 Braille
11B-703.3.1 Dimensions and
Capitalization
Technical requirements for Braille
1117B.5.7 Mounting location and
height.
11B-703.4.1 Height Above
Finish Floor or Ground
11B-703.4.2 Location
Technical requirements for mounting
location and height
1117B.5.8 Symbols of
accessibility.
11B-703.7.2 Symbols
Technical requirements for symbols of
accessibility
1117B.5.8.1 International
Symbol of Accessibility.
11B-703.7.2.1 International
Symbol of Accessibility
Technical requirements for International
Symbol of Accessibility
Exception
N/A
1117B.5.8.1.1 Color of symbol.
11B-703.7.2.1 International
Symbol of Accessibility
Technical requirements for International
Symbol of Accessibility
Exception
11B-703.7.2.1 Exception
Technical requirements for International
Symbol of Accessibility
1117B.5.8.1.2 Entrance signs.
11B-216.6 Entrances
Scoping for sign requirements at entrance
doors
Exception 1
11B-216.6 Entrances,
Exception 1
Scoping for sign requirements at entrance
doors
Exception 2
11B-216.6 Entrances,
Exception 2
Scoping for sign requirements at entrance
doors
1117B.5.8.1.3 Information
posted.
11B-216.7 Elevators
11B-216.8 Toilet Rooms and
Bathing Rooms
Scoping for signs providing information
about specific accessible elements
Cross Reference Guide - 2010 CBC to 2013 CBC Page 51 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1117B.5.8.2 International TTY
symbol.
11B-216.9 TTYs
11B-703.7.2.2 International
Symbol of TTY
Scoping and technical requirements for
International Symbol of TTY
1117B.5.8.3 Volume control
telephones.
11B-703.7.2.3 Volume Control
Telephones
Scoping and technical requirements for
volume control telephones
1117B.5.8.4 Assistive listening
systems.
11B-216.10 Assistive
Listening Systems
11B-703.7.2.4 Assistive
Listening Systems
Scoping and technical requirements for
assistive listening systems
1117B.5.9 Traffic-control
devices.
11B-703.7.2.7 Pedestrian
Traffic-Control Buttons
Scoping and technical requirements for
pedestrian traffic-control buttons
1117B.5.10 Signs for text
telephones.
N/A
Reference to “TDD” designation not
carried forward.
1117B.5.11 Cleaner air symbol.
11B-216.13.1 Cleaner Air
Symbol
11B-703.7.2.5 Cleaner Air
Symbol
Scoping and technical requirements for
cleaner air symbol
1117B.5.11.1 Color and size of
symbol.
11B-703.7.2.5 Cleaner Air
Symbol
Technical requirements for cleaner air
symbol
1117B.5.11.2 Conditions of use.
11B-216.13.1 Use of Cleaner
Air Symbol
Scoping for use of cleaner air symbol
1117B.5.11.3 Removal of
symbol.
11B-216.13.2 Removal of
Cleaner Air Symbol
Scoping for removal of cleaner air symbol
1117B.6 Controls and operating
mechanisms.
11B-205 Operable Parts
General scoping for operable parts
1. General.
11B-205.1 General
11B-309.1 General
General scoping for operable parts
2. Clear floor space.
11B-309.2 Clear Floor Space
Technical requirements for clear floor
space
3. Height.
11B-309.3 Height
Technical requirements for height
Exception
11B-205.1 General, Exceptions
General scoping for operable parts
4. Operation.
11B-309.4 Operation
Technical requirement for operation
5. Installation heights of
electrical switches and
receptacle outlets.
11B-308.1.1 Electrical
Switches
11B-308.1.2 Electrical
Receptacle Outlets
Technical requirements for electrical
switches and receptacle outlets
5.1. Electrical switches.
11B-308.1.1 Electrical Switches
Technical requirements for electrical
switches
Cross Reference Guide - 2010 CBC to 2013 CBC Page 52 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
5.2. Electrical receptacle
outlets
11B-308.1.2 Electrical
Receptacle Outlets
Technical requirements for electrical
receptacle outlets
Exception 1
11B-205.1 General, Exceptions
General scoping for operable parts
Exception 2
11B-205.1 General, Exceptions
General scoping for operable parts
Exception 3
11B-205.1 General, Exceptions
General scoping for operable parts
Exception 4
11B-205.1 General, Exceptions
General scoping for operable parts
1117B.7 Automated teller
machines and point of sale
machines.
11B-220 Automatic Teller
Machines, Fare Machines and
Point-of-Sale Devices
General scoping for automatic teller
machines
1117B.7.1 General.
11B-220.1 Automatic Teller
Machines and Fare Machines
General scoping for automatic teller
machines
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 3
11B-308.3.1, Exception 2
Exception for operable parts of fuel
dispensers
1117B.7.1.1
11B-220.1 Automatic Teller
Machines and Fare Machines
Scoping for automatic teller machines
1117B.7.1.1.1 One ATM.
11B-220.1.1 One Automatic
Teller Machine or Fare
Machine
Scoping for automatic teller machines
1117B.7.1.1.2 Two ATMs
11B-220.1.2 Two Automatic
Teller Machines or Fare
Machines
Scoping for automatic teller machines
1117B.7.1.1.3 Three or more
ATMs
11B-220.1.3 Three or More
Automatic Teller Machines or
Fare Machines
Scoping for automatic teller machines
Cross Reference Guide - 2010 CBC to 2013 CBC Page 53 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1117B.7.1.2 Where bins …
11B-220.1 Automatic Teller
Machines and Fare Machines
Scoping for bins for envelopes, waste or
other purposes
1117B.7.1.3 (point-of-sale)
11B-220.2 Point-of-Sale
Devices
Scoping for point-of-sale devices
1117B.7.2 Clear floor or ground
space.
11B-707.2 Clear Floor or
Ground Space
Technical requirements for clear floor
space
Exception
11B-707.2 Exception
Exception for drive-up only machines
1117B.7.3 Operable parts.
11B-707.3 Operable Parts
Technical requirements for operable parts
Exception
11B-707.3 Exception
Exception for drive-up only machines
1117B.7.3.1 (clear key)
11B-707.5 Speech Output
11B-707.6.1 Input Controls
11B-707.6.3.2 Tactile
Symbols
Technical requirements for operable parts
discernible by sound or touch
1117B.7.4 Privacy.
11B-707.4 Privacy
Technical requirements for same degree
of privacy of input and output
1117B.7.5 Speech output.
11B-707.5 Speech Output
Technical requirements for speech output
Exception 1
11B-707.5, Exception 1
Technical requirements for speech output
Exception 2
11B-707.5, Exception 2
Technical requirements for speech output
Exception 3
11B-707.5, Exception 3
Technical requirements for speech output
1117B.7.5.1 User control.
11B-707.5.1 User Control
Technical requirement for user control of
speech function
Exception
11B-707.5.1, Exception
Technical requirement for user control of
speech function
1117B.7.5.2 Receipts.
11B-707.5.2 Receipts
Technical requirements for receipts
Exception 1
11B-707.5.2, Exception 1
Technical requirements for receipts
Exception 2
11B-707.5.2, Exception 2
Technical requirements for receipts
Exception 3
11B-707.5.2, Exception 3
Technical requirements for receipts
1117B.7.6 Input.
11B-707.6 Input
Technical requirements for input controls
1117B.7.6.1 Input controls.
11B-707.6.1 Input Controls
Technical requirements for input controls
1117B.7.6.2 Numeric keys.
11B-707.6.2 Numeric Keys
Technical requirements for input controls
1117B.7.6.3 Function keys.
11B-707.6.3 Function Keys
Technical requirements for input controls
1117B.7.6.3.1 Contrast
11B-707.6.3.1 Contrast
Technical requirements for input controls
Cross Reference Guide - 2010 CBC to 2013 CBC Page 54 of 106
Section 1117B Other Building Components 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Exception
11B-707.6.3.1, Exception
Technical requirements for input controls
1117B.7.6.3.2 Tactile symbols.
11B-707.6.3.2 Tactile Symbols
Technical requirements for input controls
1117B.7.7 Display screen.
11B-707.7 Display Screen
Technical requirements for display
screens
Exception
11B-707.7, Exception
Technical requirements for display
screens
1117B.7.7.1 Visibility.
11B-707.7.1 Visibility
Technical requirements for display
screens
1117B.7.7.1.1 Vertically
mounted display screen.
11B-707.7.1.1 Vertically
Mounted Display Screen
Technical requirements for display
screens
1117B.7.7.1.2 Angle-mounted
display screen.
11B-707.7.1.2 Angle Mounted
Display Screen
Technical requirements for display
screens
1117B.7.7.1.3 Horizontally
mounted display screen.
11B-707.7.1.3 Horizontally
Mounted Display Screen
Technical requirements for display
screens
1117B.7.7.2 Characters.
11B-707.7.2 Characters
Technical requirements for characters
displayed on the screen
1117B.7.8 Braille instructions.
11B-707.8 Braille Instructions
Technical requirements for Braille
instructions
1117B.7.9 Point-of-sale devices
11B-707.9 Point-of-Sale
Devices
11B-707.9.1 General
Technical requirements for point-of-sale
devices
1117B.7.9.1
11B-707.9.1.1 Tactilely
Discernible Numerical Keypad
Technical requirements for point-of-sale
devices
1117B.7.9.2
11B-707.9.1.2 Other
Technology
Technical requirements for point-of-sale
devices
1117B.8 Fitting and dressing
rooms.
11B-222 Dressing, Fitting and
Locker Rooms
11B-803 Dressing, Fitting and
Locker Rooms
11B-903 Benches
Scoping and technical requirements for
dressing and fitting rooms, including clear
space, benches, coat hooks and mirrors
1117B.9 Accessible sinks.
11B-212.3 Sinks
General scoping for sinks
1.
11B-606.2 Clear Floor Space
Technical requirements for clear floor
space
2.
11B-606.3 Height
11B-606.2 Clear Floor Space
11B-606.5 Exposed Pipes
and Surfaces
11B-606.7 Sink Depth
Technical requirements for height, knee &
toe clearance, depth and exposed pipes
3.
11B-606.4 Faucets
Technical requirements for control
Cross Reference Guide - 2010 CBC to 2013 CBC Page 55 of 106
Section 1117B Other Building Components 5 February 2013
Section 1118B Space Allowance and Reach Ranges
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1118B.1 Wheelchair passage
width.
11B-403.5.1 Clear Width
11B-403.5.1, Exception 1
11B-403.5.2 Clear Width at
Turn
Technical requirements for clear width,
clear width at a point and clear width at
turns around obstructions
1118B.2 Width for wheelchair
passing.
11B-403.5.3 Passing Spaces
Technical requirements for passing
spaces
1118B.3 Wheelchair turning
space.
11B-304.3 Size
Technical requirements for turning space
circular or T-shaped
1118B.4 Clear floor or ground
space for wheelchairs.
11B-305 Clear Floor or Ground
Space
Technical requirements for clear floor or
ground space
1. Size and approach.
11B-305.3 Size
11B-305.4 Knee and Toe
Clearance
11B-305.5 Position
Technical requirements for clear floor or
ground spacesize, knee & toe space,
parallel or forward approach
2. Relationship of
maneuvering clearances to
wheelchair spaces.
11B-305.6 Approach
11B-305.7 Maneuvering
Clearance
Technical requirements for clear floor or
ground space accessible route and
maneuvering clearances at alcoves
3. Surfaces for wheelchair
spaces.
11B-305.2 Floor or Ground
Surfaces
Technical requirements for clear floor or
ground spacefloor or ground surface
1118B.5 Forward reach.
11B-308.2 Forward Reach
Technical requirements for forward reach
1118B.5.1 Unobstructed.
11B-308.2.1 Unobstructed
Technical requirements for forward reach
1118B.5.2 Obstructed high
reach.
11B-308.2.2 Obstructed High
Reach
Technical requirements for forward reach
1118B.6 Side reach.
11B-308.3 Side Reach
Technical requirements for side reach
1118B.6.1 Unobstructed.
11B-308.3.1 Unobstructed
Technical requirements for side reach
Exception
11B-308.3.1, Exception 1
Technical requirements for side reach
1118B.6.2 Obstructed High
reach.
11B-308.3.2 Obstructed High
Reach
Technical requirements for side reach
Exception
11B-308.3.2, Exception 1
Technical requirements for side reach
Cross Reference Guide - 2010 CBC to 2013 CBC Page 56 of 106
Section 1118B Space Allowance and Reach Ranges 5 February 2013
Section 1119B Special Standards of Accessibility for Buildings with Historical
Significance
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
See Section 1135B
11B-202.5 Alterations to
Qualified Historic Buildings and
Facilities.
Current reference to State Historic
Building Code accessibility provisions is
maintained in 2013 CBC.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 57 of 106
Section 1119B Special Standards of Accessibility for Buildings with Historical Significance 5 February 2013
Section 1120B Floor and Levels
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1120B.1 Floors within each
story.
11B-206 Accessible Routes
11B-302 Floor or Ground
Surfaces
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 3
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 4
N/A
1120B.2 Floor surface.
11B-302.1 General
Technical requirement for slip resistant
floor surfaces
Cross Reference Guide - 2010 CBC to 2013 CBC Page 58 of 106
Section 1120B Floors and Levels 5 February 2013
Section 1121B Transportation Facilities
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1121B.1 General.
11B-810 Transportation
facilities
11B-206 Accessible Route
11B-206.2.3 Exception 2.2
Elevator requirements
Technical requirements for transportation
facilities.
Scoping for accessible route.
Scoping for elevators.
1121B.2 Bus stops and
terminals.
11B-209.2.2 Bus Loading
Zones
Scoping for bus loading zones.
1121B.2.1 New construction.
11B-810.2.1 Surface
11B-810.2.2 Dimensions
11B-810.2.3 Connections
11B-810.2.4 Slope
11B-810.3 Bus Shelters
11B-810.4 Bus Signs
11B-705.1.2.4 Bus Stops
Technical requirements for bus boarding,
alighting areas and bus shelters.
Technical requirements for detectable
warnings and square curbs.
1121B.2.2 Bus stop siting and
alterations.
11B-209.2.2 Bus Loading
Zones
11B-209.2.3 On-Street Bus
Stops
11B-218.4 Bus Shelters
Scoping for bus loading zones.
1.
11B-402.2 Accessible Route
Components
Technical requirements for components of
accessible routes.
2.
11B-810.4 Bus Signs
Technical requirements for bus signs.
1121B.3 Fixed facilities and
stations.
11B-218 Transportation
Facilities
11B-810 Transportation
Facilities
Scoping for transportation facilities
Technical requirements for transportation
facilities
1121B.3.1 New construction.
11B-201.1 Scope
Scoping for new construction and
alterations for facilities.
1.
11B-206.3 Location
11B-216.6 Entrance
Scoping for location of accessible route to
coincide with general circulation path.
Scoping for signage located where
accessible route diverges from regular
circulation path.
2.
11B-206.4.1 General
11B-206.4.4 Transportation
Facilities
Scoping requires all entrances and
exterior ground-floor exit doors to
buildings and facilities to be accessible.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 59 of 106
Section 1121B Transportation Facilities 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3.
11B-206.2.1 Site Arrival
Points
11B-206.4.2.2 Direct
Connections
Scoping for accessible route provided
within the site to facilities and
transportation stops.
4.
11B-216.6 Entrances
11B-810.6.1 Entrances
Scoping for signage located at entrances.
Technical requirements for signage at rail
stations.
5.
11B-810.6 Entrances
11B-810.6.3 Station Names
Technical requirements for signage at rail
stations.
6.
11B-810.6.2 Routes and
Destinations
Technical requirements for signage at rail
stations.
7.
11B-220.1 General Automatic
Teller and Fare Machines and
Point-of-Sale Devices
11B-707.2 Clear Floor and
Ground Space
11B-404 Doors, Doorways,
and Gates
Scoping for fare machines.
Technical requirements for fare machines.
Technical requirements for doors and
gates.
8.
11B-810.5.2 Detectable
Warnings
Technical requirements for detectable
warnings at platform edges.
(a) Detectable warnings
at transit boarding
platforms.
11B-705.1.2.1 Platform Edges
11B-705.1 Detectable
Warnings
11B-705.3 Product Approval
11B-705.1.1.3 Contrast
Technical requirements for detectable
warnings at platforms edges.
Technical requirements for detectable
warnings.
Technical requirements for product
approval.
Technical requirements for contrast
formula.
(b) Detectable
directional texture at
boarding platforms.
11B-705.2 Detectable
Directional Texture
11B-705.3 Product Approval
Technical requirements for detectable
directional texture.
Technical requirements for product
approval.
9.
11B-810.5.3 Platform and
Vehicle Floor Coordination
Technical requirements for platform and
vehicle floor coordination.
Exception 1
11B-810.5.3 Platform and
Vehicle Floor Coordination
Technical requirements for platform and
vehicle floor coordination.
Requirements further defined in 36 CFR
Part 1192.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 60 of 106
Section 1121B Transportation Facilities 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Exception 2
11B-810.5.3 Platform and
Vehicle Floor Coordination
Technical requirements for platform and
vehicle floor coordination.
Requirements further defined in 36 CFR
Part 1192.
10.
11B-810.1 Vehicle Boarding
Technical requirements for vehicle
boarding.
11.
N/A
Not carried forward
12.
11B-217.4 TTYs
Technical requirements for TTYs
a.
11B-217.4.1 Bank Requirement
11B-217.4.7 Transportation
Facilities
Scoping for required number of TTYs
b.
11B-217.4.3.1 Public Buildings
Scoping for required number of TTYs in
public buildings
13.
11B-247.1.2.7 Track Crossings
11B-705.1.2.7 Track Crossings
Model code amended to provide scoping
and technical requirements for detectable
warnings at track crossings.
14.
11B-218.5 Other
Transportation Facilities
11B-810.7 Public Address
Systems
Scoping requirement for public address
systems and visual format.
Technical requirement for public address
systems and visual format.
15.
11B-218.5 Other
Transportation Facilities
11B-810.8 Clocks
Scoping requirement for public address
systems and visual format.
Technical requirements for clocks.
16.
11B-810.9 Escalators
Technical requirements for escalators.
Additional requirements defined in ASME
A17.1
17.
N/A
Not carried forward, security issue not
access related.
Exception
N/A
Related to Item 17, not carried forward.
18.
11B-904.4 Sales and Service
Counters
11B-904.4.1 Parallel
Approach
11B-904.4.2 Forward
Approach
Technical requirements for sales and
service counters.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 61 of 106
Section 1121B Transportation Facilities 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
19.
11B-810.1.3 Baggage
Retrieval Systems
11B-206.8 Security Barriers
11B-404.2.10 Door and Gate
Surfaces
Technical requirements for baggage
retrieval systems.
Scoping for security barriers.
Technical requirements for gates.
1121B.3.2 Existing facilities
alterations.
11B-202.3 Alterations
11B-202.4 Path of Travel
11B-218.2 New and Altered
Fixed Guideway Systems.
Scoping for alterations in transportation
facilities.
1121B.4 Airports.
N/A
Title only in 2010 CBC.
1121B.4.1 New construction.
11B-201.1 Scope
11B-218.5 Other
Transportation Facilities
Scoping for all areas of newly designed
and constructed buildings and facilities.
1.
11B-206.3 Location
Scoping for location of accessible route to
coincide with general circulation path.
2.
11B-216.6 Entrance
Scoping for signage located where
accessible route diverges from regular
circulation path.
3.
11B-904.4 Sales and Service
Counters
11B-904.4.1 Parallel
Approach
11B-904.4.2 Forward
Approach
Technical requirements for sales and
service counters.
4.
11B-217.4.1 Bank
Requirement
11B-217.4.7 Transportation
Facilities
Scoping for required number of TTYs
5.
11B-810.1.3 Baggage
Retrieval Systems
11B-206.8 Security Barriers
11B-404.2.10 Door and Gate
Surfaces
Technical requirements for baggage
retrieval systems.
Scoping for security barriers.
Technical requirements for gates.
6.
11B-218.5 Other
Transportation Facilities
11B-810.7 Public Address
Systems
Scoping requirement for public address
systems and visual format.
Technical requirement for public address
systems and visual format.
7.
11B-810.8 Clocks
Technical requirements for clocks.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 62 of 106
Section 1121B Transportation Facilities 5 February 2013
Section 1122B Fixed or Built-In Seating, Tables and Counters
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1122B.1 Minimum number.
11B-206.2.4 Spaces and
Elements
11B-226.1 General
Scoping for fixed or built-in seating or
tables
1122B.2 Seating.
11B-902.2 Clear Floor or
Ground Space
Technical requirements for clear floor
space
1122B.3 Knee clearance.
11B-306.2.3, Exception 2
11B-306.3.3, Exception 3
11B-306.3.4, Exception 2
11B-902.2 Clear Floor or
Ground Space
Technical requirements for knee and toe
clearance
Exception
11B-226.1, Exception 1
Exception for knee and toe clearance at
sales and service counters
1122B.4 Height of work
surfaces.
11B-226.1 General
11B-902.3 Height
Scoping and technical requirements for
height of work surfaces
1122B.5 Sales and service
counters, teller windows and
information counters.
11B-227.3 Counters
11B-904.4 Sales and Service
counters
Scoping and technical requirements for
sales and service counters
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 63 of 106
Section 1122B - Fixed or Built-In Seating, Tables and Counters 5 February 2013
Section 1123B Access to Employee Areas
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1123B.1 General.
11B-203.9 Employee Work
Areas
General scoping for employee work areas
1123B.2 Work stations.
11B-203.9 Employee Work
Areas
11B-206.2.8 Employee Work
Areas
General scoping for employee work areas
including accessible route
Exception
11B-203.3 Raised Areas
11B-203.4 Limited Access
Spaces
11B-203.5 Machinery Spaces
Exception to the requirements of
accessibility
Cross Reference Guide - 2010 CBC to 2013 CBC Page 64 of 106
Section 1123B Access to Employee Areas 5 February 2013
Section 1124B Ground and Floor Surfaces
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1124B.1 General.
11B-302 Floor and Ground
Surfaces
11B-302.1 General
Technical requirements for floor and
ground surfaces slip resistance
1124B.2 Changes in level.
11B-303 Changes in Level
Technical requirements for floor and
ground surfaces changes in level
1124B.3 Carpet.
11B-302.2 Carpet
Technical requirements for floor and
ground surfaces carpet
1124B.4 Gratings.
11B-302.4 Openings
Technical requirements for floor and
ground surfaces openings or gratings
Cross Reference Guide - 2010 CBC to 2013 CBC Page 65 of 106
Section 1124B Ground and Floor Surfaces 5 February 2013
Section 1125B Storage
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1125B.1 General.
11B-225.2 Storage
Scoping for storage
1125B.2 Clear floor space.
11B-811.2 Clear Floor or
Ground Space
Technical requirements for storage
1125B.3 Height.
11B-811.3 Height
Technical requirements for storage
1125B.4 Hardware.
11B-811.4 Operable Parts
Technical requirements for storage
Cross Reference Guide - 2010 CBC to 2013 CBC Page 66 of 106
Section 1125B Storage 5 February 2013
Section 1126B Vending Machines and Other Equipment
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1126B Vending machines and
other equipment
11B-228 Depositories,
Vending Machines, Change
Machines, Mail Boxes and
Fuel Dispensers
11B-309 Operable Parts
Scoping for vending machines and other
type of equipment
Technical requirements for operable parts
Cross Reference Guide - 2010 CBC to 2013 CBC Page 67 of 106
Section 1126B Vending Machines and Other Equipment 5 February 2013
Section 1127B Exterior Routes of Travel
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1127B.1 General.
11B-206.2.1 Site Arrival
Points
11B-206.2.2 Within a Site
11B-206.3 Location
11B-206.4 Entrances
Scoping for site and entrance accessibility
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1127B.2 Design and
construction.
11B-201.1 Scope
Scoping for construction of buildings and
facilities
1127B.3 Signs.
11B-216.6 Entrances
Scoping for signs where accessible routes
diverge from the regular circulation path
1127B.4 Outside stairways.
N/A
1127B.5 Curb ramps.
11B-402.2 Components
11B-406 Curb Ramps,
Blended Transitions and
Islands
Scoping and technical requirements for
curb ramps
1. General.
11B-406.5.1 Location
Technical requirements for curb ramps
location
2. Width of curb ramps.
11B-406.5.2 Width
Technical requirements for curb ramps
width
3. Slope of curb ramps.
11B-406.2.1 Slope
11B-406.3.1 Slope
11B-406.4.1 Slope
Technical requirements for curb ramps -
slope
4. Level landing.
11B-406.2.2 Sides of Curb
Ramps
11B-406.5.3 Landings
Technical requirements for curb ramps
landings and slope of curb ramp flares
Cross Reference Guide - 2010 CBC to 2013 CBC Page 68 of 106
Section 1127B Exterior Routes of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
5. Finish.
N/A
Detectable warning satisfies the
requirement for contrast.
6. Border.
11B-406.5.11 Grooved Border
Technical requirements for curb ramps
grooved border
7. Detectable warnings.
11B-406.5.12 Detectable
Warnings
11B-705.1.2.2 Curb Ramps
Technical requirements for curb ramps
detectable warnings
8. Obstructions.
11B-406.5.1 Location
Technical requirements for curb ramps
obstruction by parked vehicles
9. Diagonal curb ramps.
11B-406.5.10 Diagonal Curb
Ramps
Technical requirements for curb ramps
diagonal curb ramps
Notes:
N/A
Generally incorporated into 11B-406.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 69 of 106
Section 1127B Exterior Routes of Travel 5 February 2013
Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses)
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1128B Pedestrian grade
separations (overpasses and
underpasses)
11B- 206.2.1 Site Arrival
Points
11B-206.2.2 Within a Site
11B-206.4.3 Entrances from
Tunnels or Elevated
Walkways
Scoping for accessible routes
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 70 of 106
Section 1128B Pedestrian Grade Separations (Overpasses and Underpasses) 5 February 2013
Section 1129B Accessible Parking Required
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1129B.1 General.
11B-208.1 General.
11B-208.3.1 General.
Table 11B-208.2 Parking
Spaces
Scoping for accessible parking
Requires parking to be on the closest
accessible route to the entrance,
dispersed when there are multiple
entrances and when parking doesn’t
serve a particular building to be on the
shortest accessible route to the entrance
of the parking facility.
The number of accessible spaces
required is shown in the table.
1129B.2 Medical care outpatient
facilities.
11B-208.2.1
11B-208.2.2, see below
Current 2010 CBC provisions are
included within the model code.
1. Outpatient units and
facilities.
11B-208.2.1 Hospital
Outpatient Facilities
Current 2010 CBC provisions are
included within the model code, which
expands the scope for a 10 percent
parking ratio to include all outpatient
facilities, not just those serving persons
with mobility impairments.
2. Units and facilities that
specialize in treatment or
services for persons with
mobility impairments.
11B-208.2.2 Rehabilitation
Facilities and Outpatient
Physical Therapy Facilities.
Current 2010 CBC provisions are
included within the model code.
1129B.3 Parking space size.
11B-208.3.1 General.
Current redundant 2010 CBC reference
eliminated.
1. Dimensions.
11B-502.2 Vehicle Spaces
11B-502.3 Access Aisle.
11B-502.3.3 Marking.
Model code is being amended to carry
forward the current 2010 CBC minimum
width of 108 inches and minimum length
of 216 inches for standard accessible
spaces.
Current provisions allowing two
accessible parking spaces to share an
access aisle are included within the
model code.
Current 2010 CBC provisions for marking
access aisles have been included by
amendment.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 71 of 106
Section 1129B Accessible Parking Required 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
2. Van space(s).
11B-208.2.4 Van Parking
Spaces.
11B-502.2 Vehicle Spaces
11B-208.3.1, Exception 1
11B-502.3.3 Marking.
11B-502.3.4 Location.
Current 2010 CBC van to standard
parking space ratio of 1 to 8 has been
superseded by more stringent model
code requirement of 1 to 6.
Model code is being amended to carry
forward the current 2010 CBC minimum
width of 144 inches and minimum length
of 216 inches for van spaces with the
option of a standard width accessible
parking space with a 96 inch minimum
width aisle.
Current 2010 CBC provisions allowing
van parking spaces to be grouped on one
level within a multi-story parking facility
are included within the model code.
Current 2010 CBC provisions for marking
access aisles have been included by
amendment.
Current 2010 CBC provisions requiring
access aisle for van spaces to be on the
passenger side have been included by
amendment.
3. Arrangement of parking
space.
11B-502.2 Vehicle Spaces
Current 2010 CBC requirement that a
person with a disability need not walk or
wheel behind any vehicle other than their
own is implemented by model code
language requiring access aisles to
adjoin an accessible route.
Exception 1.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 72 of 106
Section 1129B Accessible Parking Required 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
4. Slope of parking space
and access aisle.
11B-502.4 Floor or Ground
Surfaces.
Model code language, with a non-
substantive adjustment of the maximum
slope to 1:48 from 1:50, carries forward
the 2010 CBC requirements.
5. Vertical clearance.
11B-502.5 Vertical Clearance.
The required 98 inch overhead clearance
for both standard and van spaces and at
least one vehicular access route serving
them is carried forward to the 2013 CBC
by amendment.
1129B.4. Identification of parking
spaces for off-street parking
facilities.
• 11B-502.6 Identification,
including sub-sections
11B-502.6.4.1 The outline of
the International Symbol of
Accessibility . . .
11B-703.7.2.1 International
Symbol of Accessibility.
California statutory requirements for the
marking, identification and signage of
accessible off-street parking facilities are
carried forward to the 2013 CBC by
amendment.
California statutory requirements for the
surface marking of each accessible
parking space are carried forward to the
2013 CBC by amendment.
Current language referring to the
depiction of a wheelchair and its
occupant has been updated to a
reference to the International Symbol of
Accessibility.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 73 of 106
Section 1129B Accessible Parking Required 5 February 2013
Section 1130B Parking Structures
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1130B.1
11B-502.5 Vertical Clearance.
The required 98 inch overhead clearance
is carried forward to the 2013 CBC.
Exception 1.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1130B.2
11B-206.4.2 Parking Structure
Entrances
The requirement that each direct
pedestrian entrance from a parking facility
must be on an accessible route is
maintained in the 2013 CBC.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 74 of 106
Section 1130B Parking Structures 5 February 2013
Section 1131B Passenger Drop-Off and Loading Zones
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1131B.1 Location.
11B-209 Passenger Loading
Zones and Bus Stops
11B-209.1 General.
Scoping for passenger drop-off and
loading zones
1131B.2 Passenger loading
zones.
N/A
Title only in 2010 CBC
1. General.
11B-209.2 Type.
11B-503 Passenger Drop-Off
and Loading Zones
Scoping and technical requirements for
passenger drop-off and loading zones
2. Vertical clearance.
11B-503.5 Vertical Clearance.
Technical requirement to maintain 114
inch clearance
1131B.3 Valet parking.
11B-209.4 Valet Parking.
Scoping and technical requirements for
valet parking
1131B.4 Bus stop pads and
shelters.
11B-209.2.2 Bus Loading
Zones
11B-209.2.3 On-Street Bus
Stops.
11B-810.2 Bus Boarding and
Alighting Areas
Scoping and technical requirements for
bus stop pads and shelters
Cross Reference Guide - 2010 CBC to 2013 CBC Page 75 of 106
Section 1131B Passenger Drop off and Loading Zones 5 February 2013
Section 1132B Outdoor Occupancies
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1132B.1 General.
11B-201.1 Scope.
11B-246 Parks and
Recreational Areas.
All areas of newly designed and newly
constructed buildings and facilities and
altered portions of existing buildings and
facilities shall comply with these
requirements.
Scoping for parks and recreational areas
1132B.2 Parks and recreational
areas.
11B-246.1 General.
Scoping for parks and recreational areas
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-246.1 General, Exception
The existing exception to preclude
material damage to the natural
environment has been carried forward.
Exception 3
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1. Campsites.
11B-246.2 Camping Facilities.
Current 2010 CBC provisions have been
included by amendment.
2. Beaches, picnic areas.
11B-246.1 General
11B-246.3 Beaches.
11B-246.4 Day Use Areas
and Vista Points
11B-246.5 Picnic Areas
Current 2010 CBC provisions have been
included by amendment.
Requirement for accessible picnic tables
has been clarified at a level consistent
with the ratios for dining areas.
Current levels of access are maintained
by the requirement for accessible routes
to buildings and other functional areas
3. Sanitary facilities.
11B-213 Toilet Facilities and
Bathing Facilities
Scoping for toilet and bathing facilities
Cross Reference Guide - 2010 CBC to 2013 CBC Page 76 of 106
Section 1132B Outdoor Occupancies 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
4. Boat docks.
11B-235 Recreational Boating
Facilities
11B-1003 Recreational
Boating Facilities
11B-237 Fishing Piers and
Platforms
11B-1005 Fishing Piers and
Platforms
The model code’s specific provisions
provide enforceable requirements in lieu
of the current 2010 CBC general
statement of intent.
5. Parking lots.
11B-502.1 General.
Technical requirements for parking
6. Trails and paths.
11B-246.7 Trails and Paths.
Current 2010 CBC provisions have been
included by amendment.
7. Nature trails.
11B-246.8 Nature Trails.
Current 2010 CBC provisions have been
included by amendment.
1132B.3 Highway rest areas.
11B-201.1 Scope.
As a primary function area, the facilities at
a highway rest stop will need to comply
with the ADA and the 2013 CBC, which
requires that “All areas of newly designed
and newly constructed buildings and
facilities and altered portions of existing
buildings and facilities shall comply with
these requirements.
1132B.3.1 Permanent facilities.
11B-201.1 Scope.
These limited specific references are
provided for in the overall 2013 Chapter
11B; the current provisions are redundant.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 77 of 106
Section 1132B Outdoor Occupancies 5 February 2013
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.1 Building accessibility.
11B-206.4 Entrances
General scoping for entrances
1133B.1.1 Entrances.
11B-206.4 Entrances
General scoping for entrances
1133B.1.1.1 Entrances and
exterior ground floor exit doors.
11B-206.4 Entrances
General scoping for entrances
1133B.1.1.1.1
11B-206.2.1 Site Arrival
Points
11B-206.2.2 Within a Site
11B-206.2.4 Spaces and
Elements
11B-206.4 Entrances
11B-404.2.3 Clear Width
Scoping and technical requirements for
entrances connection to public
transportation stops, passenger loading
zones, parking and all accessible spaces
and elements within the building or
facility.
Technical requirements differ from ADAS
by requiring all entrances and exterior
ground floor exits to be accessible
Exception 1
11B-206.4.1, Exception 1
Exception for exterior ground floor exits
serving smoke-proof enclosures,
stairwells and exit doors servicing stairs
only
Exception 2
11B-206.4.1, Exception 2
Exception for exits in excess of those
required by Chapter 10 and more than 24”
above grade
Exception 3
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 4
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.1.1.1.2 Temporary
restrictions.
11B-108 Maintenance of
Accessible Features
Scoping for maintenance of accessible
features.
1133B.1.1.1.3 Recessed
doormats.
11B-302.1 Floor or Ground
Surfaces
11B-302.2 Carpet
Technical requirements for floor or ground
surfaces.
Technical requirement for carpet.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 78 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.1.1.1.4 Gates.
11B-206.5 Doors, Doorways
and Gates
General scoping for doors, doorways and
gates
1133B.1.1.1.5 Service
entrances.
11B-206.4.8 Service Entrances
Model code amended to require service
entrance shall not be the sole accessible
entrance unless it is the only entrance to
a building or facility.
1133B.2 Doors.
11B-206.5 Doors, Doorways
and Gates
11B-404.1 General
General scoping and technical
requirements for doors, doorways and
gates
1133B.2.1 Type of lock or latch.
Chapter 10, Section 1008.1.9
Door operations
11B-404.2.7 Door and Gate
Hardware
Technical requirements for door
operations
1133B.2.2 Width and height.
11B-404.2.3 Clear Width
Technical requirements for door width,
height and clear width. Provides for
consistency with 2010 ADAS and Chapter
10 CBC.
Exception
11B-404.2.3 Clear Width
Exception 3
Model code amended for doors not
requiring full user passage, such as at
shallow closets 20” minimum clear
opening.
1133B.2.3 Hinged doors.
11B-404.2.3 Clear Width
Technical requirements for doors
openings measured with door open 90
degrees
1133B.2.3.1 Pairs of doors.
11B-404.2.2 Double-Leaf
Doors and Gates
11B-404.2.3 Clear Width
Technical requirements for doors pairs
of doors
1133B.2.3.2 Automatic and
power-assisted doors.
11B-404.3 Automatic and
Power-Assisted Doors and
Gates
Technical requirements for doors
automatic and power-assisted doors
Exception 1
11B-404.2.3, Exception 1
Exception to the door clear width
requirements in alterations
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 79 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.2.3.3 Revolving doors.
11B-404.2.1 Revolving Doors,
Gates and Turnstiles
Technical requirements for doors
revolving doors shall not be part of an
accessible route
1133B.2.3.4 Turnstiles, rails and
pedestrian controls.
11B-206.3 Location
Scoping for location of accessible route to
coincide with or be located in the same
area as general circulation paths.
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.2.4 Floor level at doors.
11B-404.2.4.4 Floor or Ground
Surface
Technical requirements for doors -
1133B.2.4.1 Thresholds.
11B-404.2.5 Thresholds
Technical requirements for doors
thresholds
1133B.2.4.2 Maneuvering
clearances at doors.
11B-404.2.4 Maneuvering
Clearances
11B-404.2.4.4 Floor or
Ground Surface
Technical requirements for doors
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors
Exception
11B-404.2.4 Maneuvering
Clearances
11B-404.2.4.4 Floor or
Ground Surface
Technical requirements for doors
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors
1133B.2.4.3
11B-404.2.4 Maneuvering
Clearances
Technical requirements for doors
maneuvering clearances at swinging
doors, doorways without doors, sliding
doors and folding doors
1133B.2.4.4
11B-404.2.6 Doors in Series
and Gates in Series
Technical requirements for doors doors
in series
1133B.2.4.5 Recessed doors.
11B-404.2.4.3 Recessed Doors
and Gates
Technical requirements for doors
recessed doors
1133B.2.5 Door opening force.
11B-404.2.9 Door and Gate
Opening Force
Technical requirements for doors
opening force
1.
11B-404.2.9, Item 3
Technical requirements for doors
opening force for required fire doors
2.
11B-404.2.9, Item 1 & 2
Technical requirements for doors
opening force for interior doors
Cross Reference Guide - 2010 CBC to 2013 CBC Page 80 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3.
11B-404.2.9,Item 4
Technical requirements for doors
opening force for exterior doors
Exception 1
11B-404.2.9, Exception 1
Exception for doors to machinery spaces
Exception 2
11B-404.2.9, Exception 2,
including items a through e
Exception for banks of doors
1133B.2.5.1 Door closer.
11B-404.2.8.1 Door Closers
and Gate Closers
Technical requirements for doors door
closer speed
1133B.2.5.2
11B-404.2.7 Door and Gate
Hardware
11B-309.4 Operation
Technical requirements for doors door
hardware
1133B.2.6 Smooth surface.
11B-404.2.10 Door and Gate
Surfaces
Technical requirements for doors
surfaces within 10 inches of the floor
1133B.3 Corridors, hallways and
exterior exit balconies.
11B-403.5.1, Clear Width
General technical requirements for width
of accessible routes
1133B.3.1 Corridor and hallway
widths.
11B-403.5.1, Exception 2
Exception to the requirement for a 36”
minimum wide accessible route
corridors serving an occupant load of 10
or more require a 44” minimum width
1133B.3.2 Corridors and
hallways over 200 feet (60 960
mm).
11B-403.5.3 Passing Spaces
Technical requirements for corridors and
hallways over 200 feet 60” width or
passing spaces
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.4 Stairways.
11B-210.1 General
Scoping for stairways
1133B.4.1 Handrails.
11B-504.6 Handrails
11B-505 Handrails
Technical requirements for handrails at
stairways
Cross Reference Guide - 2010 CBC to 2013 CBC Page 81 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.4.1.1 Required handrails.
11B-505.2 Where Required
11B-505.3 Continuity
Technical requirements for handrails at
stairwaysalong both sides, continuous
1133B.4.2 Handrail
configuration.
N/A
1133B.4.2.1
11B-505.4 Height
Technical requirements for handrails at
stairwaysheight
1133B.4.2.2
11B-505.10 Handrail
Extensions
11B-505.10.2 Top Extension
at Stairs
11B-505.10.3 Bottom
Extension at Stairs
Technical requirements for handrails at
stairwaysextensions at top and bottom
Exception 1
11B-505.3 Continuity
Technical requirements for handrails at
stairways switchback or dogleg stairs
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.4.2.3
11B-505.10 Handrail
Extensions
11B-505.10.2 Top Extension
at Stairs
11B-505.10.3 Bottom
Extension at Stairs
Technical requirements for handrails at
stairwaysextensions at top and bottom
1133B.4.2.4
11B-505.10 Handrail
Extensions
Technical requirements for handrails at
stairwayshandrail orientation
1133B.4.2.5
11B-505.5 Clearance
Technical requirements for handrails at
stairways - clearance
1133B.4.2.6 Handgrips.
11B-505.6 Gripping Surface
11B-505.7 Cross Section
11B-505.8 Surfaces
Technical requirements for handrails at
stairwaysgripping surface
Cross Reference Guide - 2010 CBC to 2013 CBC Page 82 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.4.3 Tactile floor
identification signs in stairways.
11B-504.8 Floor Identification
Technical requirements for stairways
tactile floor level identification signs
This requirement was brought forward
from the 2010 CBC, not a requirement of
the 2010 ADAS
1133B.4.4 Striping for the
visually impaired.
11B-504.4.1 Contrasting Stripe
Technical requirements for stairways
contrasting stripe
This requirement was brought forward
from the 2010 CBC, not a requirement of
the 2010 ADAS
1133B.4.5 Stair treads, risers
and nosing.
11B-504.2 Treads and Risers
Technical requirements for stairways -
tread depth and riser height
1133B.4.5.1 Treads.
11B-504.4 Tread Surface
11B-504.7 Wet Conditions
Technical requirements for stairways
tread surface slip resistance and wet
conditions
1133B.4.5.2 Risers.
11B-504.3 Open risers
11B-504.5 Nosings
Technical requirements for stairways
open risers not permitted and riser slope
Exception 1
11B-504.3, Exception 1
Exception for open risers at exterior
stairways ½” opening
Exception 2
11B-504.3, Exception 2
Exception for open risers at exterior
stairways grating
1133B.4.5.3 Nosing.
11B-504.5 Nosings
Technical requirements for stairways
nosings
Exception 1
11B-504.5, Exception
Exception for existing buildings
Cross Reference Guide - 2010 CBC to 2013 CBC Page 83 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 3
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.5 Ramps.
11B-402.2 Components
11B-405 Ramps
General technical requirements for ramps
1133B.5.1 General.
11B-403.3 Slope
11B-405.1 General
Technical requirements for ramps - slope
1133B.5.2 Width
11B-405.5 Clear Width
Technical requirements for ramps - width
1133B.5.3 Slope.
11B-405.2 Slope
11B-405.6 Rise
Technical requirements for ramps
maximum slope and rise
1133B.5.3.1
11B-405.3 Cross Slope
Technical requirements for ramps
maximum cross slope
1133B.5.4 Landings.
11B-405.7 Landings
11B-405.7.1 Slope
Technical requirements for ramp landings
general requirement for level landings
1133B.5.4.1 Location of
landings.
11B-405.6 Rise
11B-405.7 Landings
Technical requirements for ramp landings
top and bottom landings at each ramp
run, rise of any ramp run not to exceed
30” maximum
1133B.5.4.2 Size of top and
bottom landings.
11B-405.7.2 Width
11B-405.7.2.1 (Top landings)
11B-405.7.3 Length
11B-405.7.3.1 (Bottom
landings)
Technical requirements for ramp landings
dimensions of top and bottom landings
1133B.5.4.3 Doors at ramp
landings.
11B-405.7.5 Doorways
Technical requirements for ramp landings
doors at landings
1133B.5.4.4 Encroachment of
doors at ramp landings.
11B-405.7.5 Doorways
Technical requirements for ramp landings
doors at landings
Cross Reference Guide - 2010 CBC to 2013 CBC Page 84 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.5.4.5 Landing width.
11B-405.7.2 Width
Technical requirements for ramp landings
width
1133B.5.4.6 Change of direction.
11B-405.7.4 Change in
Direction
Technical requirements for ramp landings
change in direction
1133B.5.4.7 Other intermediate
landings.
11B-405.7.3 Length
Technical requirements for ramp landings
length of intermediate landings
1133B.5.4.8
11B-405.7.2 Width
11B-405.7.3 Length
Technical requirements for ramp landings
dimensions of top and bottom landings
1133B.5.4.9 Hazards.
11B-405.9 Edge Protection
11B-405.9.2 Curb or Barrier
Technical requirements for ramps edge
protection
1133B.5.5 Handrails for ramps.
11B-405.8 Handrails
General technical requirements for ramp
handrails
1133B.5.5.1
11B-405.8 Handrails
11B-307.2 Protrusion Limits
Exception
11B-505.1 General
11B-505.2 Where Required
11B-505.3 Continuity
11B-505.4 Height
11B-505.5 Clearance
11B-505.6 Gripping Surface
11B-505.7 Cross Section
11B-505.8 Surfaces
11B-505.9 Fittings
11B-505.10 Handrail
Extensions
11B-505.10.1 Top and Bottom
Extension at Ramps
Technical requirements for ramp
handrails continuity, height, clear
between wall, gripping surface
dimensions, smooth surfaces, fittings and
top and bottom extensions
Provision for handrails to project into the
required clear width a distance of 3-1/2
inches from each side of a ramp at the
handrail height not carried forward to
allow for 2010 ADAS non-circular handrail
cross section.
Exception 1
11B-405.8, Exception 2
Exception for handrails adjacent to fixed
seating in assembly areas
Exception 2
11B-405.8, Exception 3
Exception for handrails at curb ramps
Exception 3
11B-405.8, Exception 4
Exception for handrails at door landings at
ramps less than 6” in rise or 72” in length
1133B.5.5.1.1 Ramp handrails.
11B-505.10 Handrail
Extensions
Exception 3
Model code amended to add handrail
extension at hazard turned 90 degrees.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 85 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.5.6 Guide curbs and
wheel guide rails.
11B-405.9 Edge Protection
11B-405.9.2 Curb or Barrier
Technical requirements for ramps edge
protection
1133B.5.6.1
11B-405.9.2 Curb or Barrier
Technical requirements for ramps edge
protection
1133B.5.6.2
11B-405.9.2 Curb or Barrier
Technical requirements for ramps edge
protection
1133B.5.7 Guards.
Chapter 10, Section 1013.2
Where required
Technical requirements for guards at
ramps located more than 30 inches above
the floor.
1133B.5.8 Outdoor ramps.
11B-405.10 Wet Conditions
Technical requirements for ramps wet
conditions
1133B.6 Aisles.
11B-403 Walking Surfaces
General technical requirements for aisles
1133B.6.1 General.
Chapter 10, Section 1017
General technical requirements for aisles
1133B.6.2 Width.
11B-403.5.1 Clear Width
11B-403.5.1, Exception
Technical requirements for aisle width
1133B.7 Walks and sidewalks.
11B-403 Walking Surfaces
11B-302.1 General
General technical requirements for walks
and sidewalks
1133B.7.1 Continuous surface.
11B-403.1 General
11B-403.2 Floor or Ground
Surface
11B-403.5.1, Exception 3
11B-403.5.3 Passing Spaces
11B-302.1 General
General technical requirements for walks
and sidewalks continuous surface, no
abrupt level changes, 48” width, and
passing spaces
Exception
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.7.1.1 Slopes less than 6
percent.
11B-403.2 Floor or Ground
Surface
Technical requirements for walks and
sidewalks slip resistant surface
1133B.7.1.2 Slopes 6 percent or
greater.
11B-403.2 Floor or Ground
Surface
Technical requirements for walks and
sidewalks slip resistant surface
1133B.7.1.3 Surface cross
slopes.
11B-403.3 Slope
Technical requirements for walks and
sidewalks slope and cross slope
Cross Reference Guide - 2010 CBC to 2013 CBC Page 86 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.7.2 Gratings.
11B-302.3 Openings
Technical requirements for walks and
sidewalks gratings or openings
Exception 1
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
Exception 2
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1133B.7.3 Five-percent gradient.
11B-401.1 Scope
Technical requirements for accessible
route components
1133B.7.4 Changes in level.
11B-403.4 Changes in Level
Technical requirements for walks and
sidewalks changes in level
1133B.7.5 Level areas.
11B-403.7 Continuous Gradient
Technical requirements for walks and
sidewalks level areas on continuous
gradients
1133B.8 Hazards.
N/A
1133B.8.1 Warning curbs.
11B-303.5 Warning Curbs
Technical requirements for changes in
level - warning curbs at abrupt changes in
level exceeding 4 inches
Requirements for warning curbs brought
forward from 2010 CBC, no comparable
requirement in the 2010 ADAS
1133B.8.2 Overhanging
obstructions.
11B-307.4 Vertical Clearance
Technical requirements for overhanging
obstructions need for guardrails or
barriers where vertical clearance is less
than 80”
1133B.8.3 Detectable warnings
at transit boarding platforms.
11B-705.1.2.1 Platform Edges
Technical requirements for detectable
warning at platform boarding edges
1133B.8.4 Detectable directional
texture at boarding platforms.
11B-705.2 Detectable
Directional Texture
Technical requirements for directional
texture at platform boarding edges
Cross Reference Guide - 2010 CBC to 2013 CBC Page 87 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1133B.8.5 Detectable warnings
at hazardous vehicular
areas.
11B-705.1.2.5 Hazardous
Vehicular Areas
Technical requirements for detectable
warning at hazardous vehicular areas
1133B.8.6 Protruding objects.
11B-204 Protruding Objects
11B-307 Protruding Objects
General technical requirements for
protruding objects
1133B.8.6.1 General.
11B-307.2 Protrusion Limits
11B-307.3 Post-Mounted
Objects
Technical requirements for protruding
objects and post-mounted objects
1133B.8.6.2 Head room.
11B-307.4 Vertical Clearance
Technical requirements for overhanging
obstructions need for guardrails or
barriers where vertical clearance is less
than 80”
1133B.8.6.3 Free-standing
signs.
11B-307.3 Post-Mounted
Objects
11B-307.3.1 Edges and
Corners
Technical requirements for post-mounted
objects and requirement to round or ease
the corners of signs
1133B.8.7 Detectable warnings
at reflecting pools.
11B-705.1.2.6 Reflecting Pools
Technical requirements for detectable
warning at reflecting pools
Cross Reference Guide - 2010 CBC to 2013 CBC Page 88 of 106
Section 1133B General Accessibility for Entrances, Exits and Paths of Travel 5 February 2013
Section 1134B Accessibility for Existing Buildings
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1134B.1 Scope, 1st paragraph
11B-201.1 Scope
11B-202.1 General
11B-202.2 Additions
Applies requirements to all areas of new
and altered buildings and facilities.
Renovations are considered an alteration
Applies requirements to additions to
existing buildings and facilities.
1134B.1 Scope, 2nd paragraph
11B-202.3.1 Prohibited
Reduction in Access
Existing 2010 CBC requirement being
maintained.
1134B.2 General.
11B-202.2 Additions
11B-202.3 Alterations
Additions must comply with the
requirements for new construction. In
alterations each element or space altered
must comply with the requirements of
Division 2 and Section 11B-202 Existing
Buildings.
1134B.2.1Primary entrance . .
. primary path of travel . . . and
sanitary facilities, drinking
fountains, signs and public
telephones serving the area (of
alteration).
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs.
Existing 2010 CBC exceptions being
maintained.
Exception 1.
Disproportionate cost
exception with threshold.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
Existing 2010 CBC exceptions being
maintained.
1.1 through 1.6 - List of
elements in priority order for
disproportionate costs
exception.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8, Items 1
through 6.
Existing 2010 CBC exceptions being
maintained.
Exception 2. Certain types of
privately funded multi-story
buildings and facilities . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9.
Existing 2010 CBC exceptions being
maintained.
2.1. Office buildings and
passenger vehicle service
stations . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 1.
Existing 2010 CBC exceptions being
maintained.
2.2. Office of physicians
and surgeons.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 2.
Existing 2010 CBC exceptions being
maintained.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 89 of 106
Section 1134B Accessibility for Existing Buildings 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
2.3. Shopping centers.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 3.
Existing 2010 CBC exceptions being
maintained.
2.4. Other buildings and
facilities . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 9, Item 4.
Existing 2010 CBC exceptions being
maintained.
Exception 3. Alterations . . .
limited to the actual work of
the project.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3.
Existing 2010 CBC exceptions being
maintained.
3.1. Altering one building
entrance . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 1.
Existing 2010 CBC exceptions being
maintained.
3.2. Altering on existing
toilet facility . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 2.
Existing 2010 CBC exceptions being
maintained.
3.3.Altering existing
elevators . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 3.
Existing 2010 CBC exceptions being
maintained.
3.4. Altering existing steps
. . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 4.
Existing 2010 CBC exceptions being
maintained.
3.5. Altering existing
handrails . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 3, Item 5.
Existing 2010 CBC exceptions being
maintained.
3.6 Alterations solely for
the purpose of barrier
removal . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4.
Existing 2010 CBC exceptions being
maintained.
3.6.1. Installing Ramps
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 1.
Existing 2010 CBC exceptions being
maintained.
3.6.2. Making curb cuts .
. .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 2.
Existing 2010 CBC exceptions being
maintained.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 90 of 106
Section 1134B Accessibility for Existing Buildings 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3.6.3. Repositioning
shelves
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 3.
Existing 2010 CBC exceptions being
maintained.
3.6.4. Rearranging . . .
furniture
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 4.
Existing 2010 CBC exceptions being
maintained.
3.6.5. Repositioning
telephones
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 5.
Existing 2010 CBC exceptions being
maintained.
3.6.6. Adding raised
markings on elevator
control buttons.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 6.
Existing 2010 CBC exceptions being
maintained.
3.6.7. Installing flashing
alarm lights
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 7.
Existing 2010 CBC exceptions being
maintained.
3.6.8. Widening doors.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 8.
Existing 2010 CBC exceptions being
maintained.
3.6.9 Installing offset
hinges . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 9.
Existing 2010 CBC exceptions being
maintained.
3.6.10 Eliminating a
turnstile or . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 10.
Existing 2010 CBC exceptions being
maintained.
3.6.11. Installing
accessible door
hardware
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 11.
Existing 2010 CBC exceptions being
maintained.
3.6.12. Installing grab
bars . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 12.
Existing 2010 CBC exceptions being
maintained.
3.6.13 Rearranging toilet
partitions . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 13.
Existing 2010 CBC exceptions being
maintained.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 91 of 106
Section 1134B Accessibility for Existing Buildings 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
3.6.14. Insulating
lavatory pipes . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 14.
11B-606.5 Exposed Pipes and
Surfaces
Existing 2010 CBC exceptions being
maintained.
Technical requirements for protecting
exposed pipes and surfaces.
3.6.15 Installing a raised
toilet seat.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 15.
Existing 2010 CBC exceptions being
maintained.
3.6.16 Installing a full
length bathroom mirror.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 16.
Existing 2010 CBC exceptions being
maintained.
3.6.17 Repositioning
paper towel dispensers .
. .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 17.
Existing 2010 CBC exceptions being
maintained.
3.6.18 Creating
designated accessible
parking spaces.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 18.
Existing 2010 CBC exceptions being
maintained.
3.6.19 Installing a paper
cup dispenser at an
existing water fountain.
N/A
Existing 2010 CBC exceptions not carried
forward.
3.6.20 Removing high-
pile low-density
carpeting.
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 4, Item 19.
Existing 2010 CBC exceptions being
maintained.
3.6.21 Installing vehicle
hand controls.
N/A
The installation of vehicular hand control
is not a building code item and has not
been retained.
3.7 Altering existing
parking lots . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 5.
Existing 2010 CBC exceptions being
maintained.
Exceptions: 4. Projects . . .
not considered alteration
projects . . .
11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 7.
Existing 2010 CBC exceptions being
maintained.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 92 of 106
Section 1134B Accessibility for Existing Buildings 5 February 2013
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1134B.2.2 Unisex toilet when
technically infeasible to install
separate toilet facilities for each
gender.
11B-202.3 Alterations.
Exception 2. Technically
Infeasible.
• 11B-202.4 Path of Travel
Requirements in Alterations,
Additions and Structural
Repairs. Exception 8.
The Unreasonable Hardship exceptions for
specific situations are replaced by
provisions for, technical infeasibility and an
unreasonable hardship for path of travel
improvements. These exceptions must be
developed by the applicant on a case-by-
case basis for submission to the enforcing
authority for its consideration and, if
approved, documentation to its file.
1134B.2.3 If alterations of Single
elements . . .
11B-202.3.3 Alterations of
Single Elements
Cross Reference Guide - 2010 CBC to 2013 CBC Page 93 of 106
Section 1134B Accessibility for Existing Buildings 5 February 2013
Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings
with Historical Significance
2010 CBC Chapter 11B 2013 CBC Chapter 11B Comments
1135B.1 General.
11B-202.5 Alterations to
Qualified Historic Buildings and
Facilities.
Current reference to State Historic
Building Code accessibility
provisions is maintained in 2013
CBC.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 94 of 106
Section 1135B Historic Preservation-Special Standards for Accessibility for Buildings 5 February 2013
with Historical Significance
Chapter 11C – Standards for Card Readers at Gasoline Fuel-Dispensing Facilities
2010 CBC Chapter 11C 2013 CBC Chapter 11B Comments
1101C.1 General.
Accessible
Chapter 2 - Section 202
Definition of Accessible
Accessible Element
Chapter 2 - Section 202
Definition of Accessible Element
Alternate Card Reader
Not carried forward
Free-Standing Pedestal
Not carried forward
Grade
Chapter 2 - Section 202
Definition of Grade
International Symbol of
Accessibility
Chapter 2 - Section 202
Definition of International Symbol of
Accessibility
Level Accessible Area
Not carried forward
Level Area
Chapter 2 - Section 202
Definition of Level Area
Recommend
Chapter 2 - Section 202
Definition of Recommend
Type of Motor Fuel
Not carried forward
Section 1102C Application
N/A
1.
11B-201.1 Scope
Scoping for new construction and
alterations required to be accessible.
2.
2.1
2.2
11B-201.1 Scope
11B-203.2 Alterations
Scoping for new construction and
alterations required to be accessible.
Does not address alteration as
removal and replacement of tanks,
piping or fuel dispensers.
Section 1103C Number of
Accessible Card Readers
11B-228 Depositories, Vending
Machines, Change Machines,
Mail Boxes, and Fuel
Dispensers
Scoping for number of fuel
dispensers required.
Section 1104C Required
Features
11B-228.1 General
Scoping for number of fuel
dispensers required to be
accessible.
1.
11B-308.3.1 Unobstructed,
Exception 2.
11B-308.3.2 Obstructed High
Reach, Exception 2.
Technical requirements for reach
range at fuel dispensers.
Exception:
Not carried forward
Cross Reference Guide - 2010 CBC to 2013 CBC Page 95 of 106
Chapter 11C Standards for Card Readers at Gasoline Fuel-Dispensing Facilities 5 February 2013
2010 CBC Chapter 11C 2013 CBC Chapter 11B Comments
2.
11B-206.2.2 Within a Site
Scoping for accessible routes to
connect accessible elements on the
same site.
3.
11B-305.6 Approach
11B-308.3.2 Obstructed High
Reach, Exception 2.
Location of clear floor or ground
space on accessible route.
Technical requirements for reach
range at fuel dispensers.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 96 of 106
Chapter 11C Standards for Card Readers at Gasoline Fuel-Dispensing Facilities 5 February 2013
Section 1101A Application
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
Section 1101A APPLICATION
Chapter 1, Scope and
Administration
Reference to Chapter 1,
Section 1.1 General
1.1.3 Scope
1.1.3.2 State Regulated
Buildings, 7.
Section 1.9 Division of the State
Architect
1.9.1.1 Application
1.9.1.1.3
Reference to Chapter 1, Scope and
Application
1101A.1 Scope
N/A
Title only in 2010 CBC
1. All newly constructed….
11B-233.3.1 Minimum Number:
New Construction
Scoping for number of publicly housing
facilities with residential dwelling units.
2. New common use
spaces…
11B-203.8 Residential
Facilities
11B-206.2.3, Item 4. Multi-
Story Buildings and Facilities
General Scoping for common use areas
in residential facilities.
3. Additions to existing
buildings…
11B-233.3.3 Additions
General Scoping for additions to existing
public housing facility.
4. Common-use areas…
11B-203.8 Residential
Facilities
11B-206.2.3, Item 4. Multi-
Story Buildings and Facilities
General Scoping for common and public
use areas in residential facilities.
5. Where any portion of a
builing…
11B-233.3.4.1 Alterations to
Vacated Buildings.
Exception
General Scoping for alterations to vacated
buildings.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 97 of 106
Section 1101A Application 5 February 2013
Section 1102A Building Accessibility
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
1102A Building Accessibility
N/A
Title only in 2010 CBC
1102A.1 Where required.
• 11B-104.2 Calculation of
Percentages
• 11B-233.3.1 Exception
• 11B-233.3.1.2.4 Exception
Scoping for number of units on a site that
must comply.
1. Apartment Buildings
• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.
Scoping for residential dwelling units.
2. Condominiums
11B-233.3 Residential
dwelling units not subject to
HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.
Scoping for residential dwelling units.
3. Lodging houses
11B-224 Transient lodging
guest rooms
Scoping for transient lodging.
4. Congregate
Residences
• 11B-224 Transient lodging
guest rooms.
• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.
Scoping for transient lodging and
residential dwelling units.
5. Dwelling with three or
more efficiency units
• 11B-233.2 Residential
dwelling units subject to HUD.
• 11B-233.3 Residential
dwelling units not subject to
HUD.
Scoping for residential dwelling units.
6. Shelters for homeless
persons
11B-224.1.5 Social service
center establishments.
Scoping for social service center
establishments.
7. Dormitories
11B-224 Transient lodging
guest rooms.
Scoping for transient lodging.
8. Timeshare dwellings
11B-224 Transient lodging
guest rooms.
Scoping for transient lodging.
9. Other Group R
occupancies
• 11B-224 Transient lodging
guest rooms.
• 11B-233 Residential
facilities.
Scoping for transient lodging and
residential dwelling units.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 98 of 106
Section 1102A Building Accessibility 5 February 2013
2010 CBC Chapter 11A
2013 CBC Chapter 11B Comments
10. Publicly funded
housing,
Chapter 2 - Definitions
Definition of public housing.
1102A.2 Existing buildings.
11B-233.3.4 Alterations
Scoping for alterations to public housing
facilities.
1102A.3 Multistory dwellings.
N/A
Title only in 2010 CBC
1102A.3.1 Multistory apartment
or condominium dwellings in
buildings with no elevator.
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception
General Scoping for number of multistory
residential dwelling units required in non-
elevator buildings.
1. The primary entry…
11B-206.4.6 Residential
dwelling unit primary entry.
11B-233.3.1.2.5 Public
housing facility site
impracticability.
General Scoping for residential dwelling
unit primary entrance and site
impracticality.
2. At least one powder
room….
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception 2
General Scoping for powder room on first
floor of multistory residential dwelling
unit.
3. At rooms or spaces on
primary entry level …
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception 3
General Scoping for accessible route on
primary entry level of multistory residential
dwelling unit.
4. Common use areas …
11B-203.8 Residential
facilities.
11B-206.2.3, Multi-story
buildings and facilities. Item 4.
General Scoping for common and public
use areas in residential facilities.
The minimum number of …..
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception
General Scoping for number of multistory
residential dwelling units required in non-
elevator buildings.
1102A.3.1 Multistory apartment
or condominium dwellings in
buildings with one or more
elevators.
11B-233.3.1.2.4 Multi-story
residential dwelling units.
General Scoping for number of multistory
residential dwelling units required in
buildings with one or more elevators.
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception: Item 2
General Scoping for powder room on first
floor of multistory residential dwelling
unit.
11B-233.3.1.2.4 Multi-story
residential dwelling units.
Exception: Item 3
General Scoping for rooms or spaces on
accessible route with Chapter 11A,
Division IV Dwelling Unit Features
Cross Reference Guide - 2010 CBC to 2013 CBC Page 99 of 106
Section 1102A Building Accessibility 5 February 2013
Section 1104A Covered Multifamily Dwellings
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
1104A.1 General.
11B-233.3.1.2.2 Non-elevator
buildings.
11B-233.3.1.2.5 Public
housing site impracticability.
General Scoping for residential dwelling
units required to be adaptable and
number exempted by site impracticality.
1104A.2 Ground floors above
grade.
11B-233.3.1.2.3 Ground floors
above grade.
General Scoping for residential dwelling
units with ground floor above grade.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 100 of 106
Section 1104A Covered Multifamily Dwellings 5 February 2013
Section 1106A Site and Building Characteristics
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
1106A.1 General Covered
multifamily dwellings with
elevators…..
2. Elevator building.
11B-233.3.1.2.1 Elevator
buildings.
General Scoping for residential dwelling
units required to be adaptable in buildings
with elevator.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 101 of 106
Section 1106A Site and Building Characteristics 5 February 2013
Section 1109A Parking Facilities
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
1109A.2.1 Private Garages.
11B-208.3.3
General Scoping for private garages
accessory to residential dwelling units.
Exception:
11B-208.3.3.2
1. A door leading…
11B-208.3.3.2, Item 1
General Scoping for access to residential
dwelling unit from private garage.
2. An accessible route…
11B-208.3.3.2, Item 2
General Scoping for access to residential
dwelling unit from private garage.
3. An accessible route…
11B-208.3.3.2, Item 3
General Scoping for access to residential
dwelling unit from private garage.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 102 of 106
Section 1109A Parking Facilities 5 February 2013
Section 1114A Exterior Ramps and Landings on Accessible Routes
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
1114A.1 Width. The width of
ramps …
2. Ramps serving accessible
entrances ….
11B-405.5 Clear Width
Exception 3.
Technical requirements for ramps serving
accessible entrance of residential dwelling
unit.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 103 of 106
Section 1114A Exterior Ramps and Landings on Accessible Routes 5 February 2013
Division IV Dwelling Unit Features
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
Section 1130A Accessible route
within covered multi-family
dwelling units
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Section 1131A - Changes in
Level
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Section 1132A - Doors
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Section 1133AKitchens
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Section 1134ABathing and
Toilet Facilities
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Section 1135ALaundry Rooms
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 104 of 106
Division IV Dwelling Unit Features 5 February 2013
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
Section 1136AElectrical
Receptacle, Switch and Control
Heights
11B-233.3.1.2 Residential
dwelling units with adaptable
features.
Scoping for adaptable residential
dwelling units in public housing facilities.
Reference to Chapter 11A, Division IV for
technical requirements of features in
adaptable residential dwelling units.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 105 of 106
Division IV Dwelling Unit Features 5 February 2013
Division VI Site Impracticality Tests
2010 CBC Chapter 11A 2013 CBC Chapter 11B Comments
Section 1150A.1 Site
Impracticality Tests
11B-233.3.1.2.5 Public
Housing Facility Site
Impracticality.
Scoping for number of residential
dwelling units required after
determination of site impracticality.
Section 1150A.2, Additional
requirements
1. Grab bar reinforcement
2. Doors
3. Communication features
4. Electrical receptacles
and switches
5. Toilet and bathing
facilities
6. Kitchen sink removable
cabinets
11B-233.3.1.2.5 Public
Housing Facility Site
Impracticality.
Scoping for features in residential
dwelling units in remaining ground floor
residential dwelling units.
Cross Reference Guide - 2010 CBC to 2013 CBC Page 106 of 106
Division VI Site Impracticality Tests 5 February 2013