DRTS 6 _GB DATA SHEET
ISA-DRTS-6-Data-Sheet-Brochure ISA-DRTS-6-Data-Sheet-Brochure
User Manual: DRTS-6-DATA-SHEET
Open the PDF directly: View PDF .
Page Count: 11
Download | |
Open PDF In Browser | View PDF |
DRTS 6 Advanced Relays, Energy Meters and Transducers Test Set • Multi-tasking test set designed for testing protection relays, energy meters, transducers. • • Powerful and lightweight. • • • • • High accuracy: better than 0.1% (standard); HP model better than 0,05%. IEC61850 Protocol interface. Up to 9 current and 6 voltage outputs plus auxiliary DC supply (option). Laptop PC or PDA control. USB and RS232 interfaces. Advanced testing and data management software TDMS. • Complete library of relays from the major manufacturers. • • Highest quality, safety and reliability. Worldwide high quality technical support in 100 countries. A P P L I C A T I O N DRTS 6 can test all the following relays RELAY TYPE Distance relay Synchronizing device Under/over-voltage relay Directional Power relay Field relay Reverse phase current relay Phase sequence voltage relay Incomplete sequence relay Instantaneous over-current relay Inverse time over-current relay Power factor relay Voltage balance relay Ground detector relay Directional over-current relay Phase angle out of step relay Automatic reclosing relay Frequency relay Pilot wire receiver relay Lockout relay Differential protection relay Voltage directional relay Power directional relay Tripping relay IEEE NO 21 25 27/59 32 40 46 47 48 50 51 55 60 64 67 78 79 81 85 86 87 91 92 94 DRTS 6 DRTS 6 SPECIFICATIONS Six phase AC/DC current outputs AC/DC current outputs 6X 6X 6X 3X 3X 3X 3X 3X 3X 3X 2X 1X 1X CURRENT A POWER VA ZMAX Ohm 0...15 0...1.5 0...0.15 0...15 0...1.5 0...0.15 0...30 0...3 0...0.3 0...15 0...45 0...90 0...30 80 0.35 0.35 0.35 0.44 0.44 0.44 0.18 0.18 0.18 0.71 0.12 0.06 0.35 100 160 160 240 480 320 RESOLUTION 1 0.1 0.1 1 0.1 0.1 2 0.2 0.2 1 3 6 2 mA mA mA mA mA mA mA mA mA mA mA mA mA . Six independent current sources with a common neutral. . Independent adjustment of current outputs. . Duty cycle: at 20°C ambient temperature: 3*15 A continuous; 6*7.5 A continuous; 6*15 A 3 minutes. . Waveform resolution: 28 bit. . Capable of stepping or ramping the current. . Rate of change programmable between ± 0.001 A/s and ± 999 A/s. . Output accuracy: ± 0.05% typical, ± 0.1% guaranteed. . Distortion: 0.1%. . Automatic protection for overloads and open circuit. Four phase AC/DC voltage outputs AC/DC voltage outputs VOLTAGE POWER V VA 4X 3X 3X 3X 1X 1X 0...300 0...300 0...125 0...12.5 0...600 0...300 85 100 100 10 200 200 ZMAX Ohm 1125 900 160 160 1800 450 RESOLUTION 4.6 4.6 1.9 190 9.2 4.6 mV mV mV µV mV mV . Four independent voltage sources, with a common neutral. . Independent adjustment of voltage outputs. . Duty cycle: continuous. 2 . Waveform resolution: 28 bit. . Capable of stepping or ramping the voltage. . Rate of change programmable between ± 0.001 V/s and ± 999 V/s. . Voltage accuracy: ± 0.05% typical, ± 0.1% guaranteed. . Distortion: 0.1%. . Automatic protection for overloads, counter-feed and short circuit. . The fourth voltage output can be selected to act as: .. Fourth voltage output V4 (AC/DC); .. Zero-sequence component VO = (V1+V2+V3)/3 or VO = (V1+V2 +V3)/1.73. Battery simulator Output voltage: 0…260 V DC, program controlled. Power: 100 W or 2 A; continuous duty. Accuracy: ± 1%. Automatic protection for overloads. Step or ramp control. Angles Phase angle range: 0° - 360°. Angle resolution: 0.01°. Angle accuracy: ± 0.1°. Step or ramp control with a rate of change between ± 0.1°/s and 999°/s. Output frequency Frequency range: from DC (0 Hz) to 2000 Hz. Transient 5 kHz. Capable of generating different frequencies on any output. Maximum frequency error: 25 µHz (0.5 ppm). Resolution: 0.1 mHz. Possibility of slewing the frequency, with a slope from 0.001 Hz/s to 999.999 Hz/s. Resolution: 0.001 Hz/s. Capable of generating waveform with superimposed harmonic distortion. Binary inputs 10 binary inputs clean or with voltage from 24 to 425 V AC and 4.5 to 600 V DC, separated in two groups of 5, with two common points isolated at 1 kV AC. Selection of the type of input: Voltage clean; 5 - 24 - 48 - 100 V; software controlled. Selection of the input debounce duration, from 0 us to 2 ms, in 64 steps of 32 us each, program controlled. Timer range: 0 - 999,999.9999 s (277 hours) or, in cycles: DRTS 6 RELAYS, ENERGY METERS AND TRANSDUCERS TEST SET 0 - 50,000,000 cycles (50 Hz); 0 - 60,000,000 cycles (60 Hz). Resolution: 0.1 ms. Timer accuracy: 0.025% of reading ± 0.1 ms. AC/DC Voltage measuring Input, High Measuring range ± 250 V. AC accuracy: 0.1% of range ± 0.1% of value. DC accuracy: 0.05% of range ± 0.05% of value. Counter inputs Interface connection These inputs allow testing energy meters, including high frequency outputs. Number of inputs: 2; with no common zero point. Frequency range: 0 to 50 kHz. Type of interface: USB and RS232 at 57.6 kbaud. Auxiliary outputs Four timed relay contacts; both normal open and normal closed provided. Characteristics of contacts with a resistive load: . Maximum voltage: 300 V AC/DC; . Maximum current: 8 A. Range of programmable delay: from 0 to 999.99 s. Power supply Mains power supply: 90 to 132 and 180 to 264 V AC, sinusoidal, single phase. Frequency: 47 to 63 Hz. Power consumption: . standby: less than 150 W; . maximum load: 1600 W. Case Aluminum, with carrying handle. Low level signal outputs Weight and dimensions The purpose of these low voltage outputs is to test protection relays that use transducers such as Rogowsky coils and voltage dividers; for this simulation low voltage inputs are necessary. Number of outputs: 6. Full range V & I output: 0... 7.26 V rms. Frequency: DC to 20 kHz. Output current: 5 mA max. Resolution: 0.43 mV or 0.043 mV. Accuracy: 0.1% of the range. Distortion: 0.1% typical. Weight: 18 kg. Dimensions: 170 (h) x 470 (w) x 430 (d) mm. Accessories supplied with the unit Protective carrying bag. Set of test leads. Power supply cable. Serial interface cable and USB cable. Ground connection cable. Instruction and maintenance manuals. TDMS software. Analog Measurements (optional): DC Current measuring Input, Low Measuring range: ± 20 mA. Accuracy: 0.02% of range ± 0.01% of value. DC Voltage measuring Input, Low Measuring range ± 10 V. Accuracy: 0.02% of range ± 0.01% of value. AC/DC Current measuring Input, High Measuring range: ± 20 A. AC accuracy: 0.2% of range ± 0.1% of value. DC accuracy: 0.1% of range ± 0.1% of value. DRTS 6 HP High Precision option This option has enhanced characteristics with respect to the standard model. This model is conceived for the test of class 0.2 energy meters. The following table summarizes the performances of the DRTS 6 HP (High Precision) version with respect to the standard one. 3 DRTS 6 STANDARD DRTS 6 ACCURACY OUTPUT CURRENT Typical: ± 0.05% ± 0.01% of range Maximum: ± 0.1% ± 0.02% of range OUTPUT VOLTAGE Typical: ± 0.05% ± 0.01% of range Maximum: ± 0.1% ± 0.02% of range PHASE ANGLE Typical: ± 0.02° Maximum: ± 0.1° 3 PHASE POWER Typical: ± 0.05% Maximum: ± 0.2% DRTS 6 HP ACCURACY OUTPUT CURRENT Typical: ± 0.02% from 0.1 to 15 A Maximum: ± 0.05% from 0.1 to 15 A OUTPUT VOLTAGE Typical: ± 0.02% from 50 to 300 V Maximum: ± 0.05% from 50 to 300 V PHASE ANGLE Typical: ± 0.01° Maximum: ± 0.02° 3 PHASE POWER Typical: ± 0.05% Maximum: ± 0.1% ADDITIONAL EXTERNAL AMPLIFIERS FOR DRTS 6 AMI 99 Three phase current amplifier The three phase current amplifier AMI 99 is an additional device to the DRTS 6. DRTS 6 in connection with AMI 99 allows to have 9 currents or 6 currents at 30 A per phase or three currents at 60 A per phase. AMI 99 with DRTS 6 CURRENT A 9X 9X 9X 6X 6X 6X 3X 3X 3X 1X 6 x 0...15 3 x 0...30 6 x 0...1.5 3 x 0...3 6 x 0...0.15 3 x 0...0.3 0...30 0...3 0...0.3 0...60 0...6 0...0.6 0...180 POWER VA ZMAX Ohm 80 160 0.35 0.18 160 0.18 0.18 0.18 0.09 0.09 0.09 0.029 320 960 RESOLUTION 230 460 23 46 2.3 4.6 460 46 4.6 920 92 9.2 2.8 AMI 99 stand alone 3X 3X 3X 1X 1X CURRENT A 0...30 0...3 0...0.3 0...30 0...90 POWER VA 160 320 480 ZMAX Ohm 0.18 0.18 0.18 0.35 0.06 RESOLUTION 460 µA 46 µA 4.6 µA 460 µA 1.38mA AMI 99 stand alone . Three independent current sources, with a common neutral. . Automatic range switch and independent range selection. . Waveform resolution: 28 bit. . Output accuracy: ± 0.1% of the output, ± 0.02% of the range. . Distortion: 0.1% total maximum, with any load. . Automatic protection for overloads. . Angle accuracy: ± 0.05°. Power supply Mains power supply: 90 to 264 V AC, single phase. Frequency: 47 to 63 Hz. Power consumption: . stanby: less than 100 W; . maximum load: 1000 W. Weight and dimensions Weight: 16 kg. Dimensions: 170 (h) x 470 (w) x 430 (d) mm. 4 µA µA µA µA µA µA µA µA µA µA µA µA mA DRTS 6 RELAYS, ENERGY METERS AND TRANSDUCERS TEST SET AMIV 66 stand alone Case Case: aluminium, with carrying handle. Accessories supplied with the unit 3X 3X 3X 1X 1X . Protective plastic bag. . Mains supply cable to DRTS 6. . Interconnecting cable to DRTS 6. CURRENT A POWER VA ZMAX Ohm 0...15 0...1.5 0...0.15 0...15 0...45 80 0.35 0.35 0.35 0.71 0.12 160 240 RESOLUTION 230 µA 23 µA 2.3 µA 230 µA 0.69 mA AMIV 66 Three phase current and two phase voltage amplifier The three phase current and two phase voltage amplifier AMIV 66 is an accessory for the DRTS 6 for tests that require nine independent currents at the same time (two secondary differential transformers), or six voltages at the same time (synchronising devices), or six currents and six voltages. The three current outputs of AMIV 66 can be generated together with DRTS 6: this also allows paralleling current outputs, thus increasing output current and power. AMIV 66 stand alone . Three independent current sources, with a common neutral. . Automatic range switch and independent range selection. . Waveform resolution: 28 bit. . Output accuracy: ± 0.1% of the output, ± 0.02% of the range. . Distortion: 0.1% total maximum, with any load. . Automatic protection for overloads. . Angle accuracy: ± 0.05°. Two phase voltage generator AMIV 66 with DRTS 6 6X 6X 6X 1X 1X AMIV 66 with DRTS 6 9X 9X 9X 3X 3X 3X 1X 0...15 0...1.5 0...0.15 0...45 0...4.5 0...0.45 0...135 POWER VA ZMAX Ohm 80 0.35 240 0.12 720 0.04 POWER VA ZMAX Ohm 0...300 0...125 0...12.5 0...600 0...300 85 85 8 400 400 1060 185 185 200 50 VOLTAGE V POWER VA ZMAX Ohm 0...300 0...125 0...12.5 0...600 0...300 100 100 10 200 200 900 160 160 1800 450 RESOLUTION 4.6 1.9 190 9.2 4.6 mV mV µV mV mV AMIV 66 stand alone Three phase current generator CURRENT A VOLTAGE V RESOLUTION 230 µA 23 µA 2.3 µA 690 µA 69 µA 6.9 µA 2 mA 2X 2X 2X 1X 1X RESOLUTION 4.6 1.9 190 9.2 4.6 mV mV µV mV mV 5 DRTS 6 AMIV 66 stand alone . Two independent voltage sources, with a common neutral. . Output frequency: from 0 Hz to 2000 Hz; transient 5 kHz. . Waveform resolution: 28 bit. . Output accuracy: ± 0.1% of the value, ± 0.02% of the range. . Distortion: 0.1% total maximum, with any load. . Automatic protection for overloads and counter-feed. . Angle accuracy: ± 0.05°. Power supply Power supply voltage: 90 to 264 V AC single phase. Frequency: 47 to 63 Hz. Power consumption: . stanby: less than 100 W; . maximum load: 500 W. Case Aluminium, with carrying handle. Accessories supplied with the unit . Power supply cable. . Relay connection cables kit. . Interconnecting cable to DRTS.6. . Plastic carrying bag. Weight and dimensions Weight: 18 kg. Dimensions: 170 (h) x 470 (w) x 360 (d) mm. AMV 66 Two phase voltage amplifier The two phase voltage amplifier AMV 66 is an accessory for the DRTS 6, for tests that require six voltages at the same time (synchronising devices). Two phase voltage generator AMV 66 with DRTS 6 6X 6X 6X 1X 1X VOLTAGE V POWER VA ZMAX Ohm 0...300 0...125 0...12.5 0...600 0...300 80 80 320 320 1125 195 195 195 50 VOLTAGE V POWER VA ZMAX Ohm 0...300 0...125 0...12.5 0...600 0...300 80 80 1125 195 195 390 97 4.6 1.9 190 9.2 4.6 mV mV µV mV mV AMV 66 stand alone 2X 2X 2X 1X 1X 160 160 RESOLUTION 4.6 1.9 190 9.2 4.6 mV mV µV mV mV AMV 66 stand alone . Two independent voltage sources, with a common neutral. . Output frequency: from 0 Hz to 2000 Hz; transient 5 kHz. . Waveform resolution: 28 bit. . Output accuracy: ± 0.1% of the output, ± 0.02% of the range. . Distortion: 0.1% total maximum, with any load. . Automatic protection for overloads and counter-feed. . Angle accuracy: ± 0.05°. Power supply Power supply voltage: 90 to 264 V AC single phase. Frequency: 47 to 63 Hz. Power consumption, maximum load: 500 W. Case Aluminium, with carrying handle. Accessories supplied with the unit . Power supply cable. . Interconnecting cable to DRTS 6. . Plastic carrying bag. 6 RESOLUTION DRTS 6 RELAYS, ENERGY METERS AND TRANSDUCERS TEST SET Weight and dimensions Weight: 7 kg. Dimensions: 170 (h) x 230 (w) x 360 (d) mm. OPTIONAL ACCESSORIES IEC61850 INTERFACE The standard IEC61850 describes the communication of devices in substations. IEC61850 messages coming from the devices connected to the substation network (such as a relay) are also called GOOSE. GOOSE messages describe binary status signals over the substation network and are also used for relays tripping . For relay testing applications within IEC 61850 substations it is necessary to access to these data. This new feature is performed by ISA Automatic Relay Test Set DRTS 6 and with the TDMS software. By means of a dedicated hardware and the TDMS software, ISA DRTS 6 can expand his testing capabilities by handling those IEC61850 messages. The IEC61850 Interface option for DRTS 6 is required for relay testing with Ethernet-based substation communication protocol. The IEC61850 Interface is mounted directly on the front panel of the DRTS 6. Primaries: 12.5 A and 15 A; Secondaries: 0.5 A; 1 A; 2.5 A; 5 A; Nominal power: 100 VA; Current ratio error: 0.2. Case: plastic. For the single phase test of the CDG relay it is possible to have three times the above power, connecting current outputs in series. I100A CURRENT BOOSTER The option I100A is a set of six current transformers, that allows to perform the following tests: - With DRTS 6, 3x50 A; - With DRTS 6 and AMI 99, 6X50 A (differential relays) or 3x100 A (over-current relays). Characteristics: Primary: 3x(2x15) +3x30 A; Secondary: 6x50 A, that can be put in parallel, to form 3x100 A; Nominal power: 6x120 VA @ 50 A, or 3x240 VA, steady; Current ratio error: 0.5; Frequency range: 40 Hz to 2 kHz. Case: plastic. Dimensions: 400 x 300 x 175 mm. Weight: 12 kg. Inputs from DRTS 6 are put in parallel inside the option: all transformers have 30 A on the primary and 50 A on the secondary. The option includes twelve connecting cables to DRTS 6 and AMI 99 current outputs. GPS SYNCHRONIZER The GPS synchronizer is an external module that allows to synchronize the test start of two DRTS 6. IN2-CDG CURRENT BOOSTER FOR 1 A RATED HIGH BURDEN RELAYS With DRTS 6 the full power of 100 VA is available only at the current of 15 A. The option IN2-CDG by means of a set of three current transformers, has the following characteristics: 7 DRTS 6 Features: . 1 digital output O-24 V DC, for synchronization. . 1 selector to program the following pulse intervals: 5 s; 10 s; 20 s; 30 s; 40 s; 60 s. . Maximum timing error with respect to nominal: 2 µs. . Lights to confirm: power-on; Locked; Pulse available. . 1 START and STOP push-button. . Power supply: 110/22O V AC. The option includes: . the antenna; . an extension cable for the antenna, 20 m long; . two cables, red and black, 2 m long, with banana terminations, for the connection to the test set trip input; . the power supply cable. Weight: 1.7 kg. Dimensions: 150 (w) x 100 (h) x 240 (d) mm. Case: aluminium. Two test sets synchronized with GPS produce the maximum error of 50 µs. The option includes: . A support to keep the scanning head in front of the energy meter; . The cable, 2 m long, from the scanning head to the DRTS 6; . The power supply transformer, for the power of 220 V AC, to supply the scanning head. . Two safety banana plugs for the connection to DRTS 6. TRANSIT CASE Three options are available: . Heavy duty transit case (Discovery type) in black plastics, with handle and wheels. . Heavy duty transit case in aluminium, with handle and wheels. . Soft carrying bag. TESTING CABLES This option includes additional cables, with different colours. SH 2003 ENERGY METERS UNIVERSAL SCANNING HEAD SH 2003 is a scanning head that eases the test of energy meters. lt is an universal scanning head because it can be used both with LED impulse electronic meters and Ferraris rotating disk meters. With rotating disk the sensor uses a green light beam that optimizes the recognition of any type of mark. SEI OPTION FOR THE SERIES CONNECTION OF CURRENTS This option is made of a set of three burdens that equalize the load for current outputs of DRTS 6. Each burden includes two resistors rated 22 Ohm 1 W; at maximum load it causes an error of – 1.6 %. The burden is easily connected to current outputs by means of three safety banana sockets plus plugs, that ease connections. PAV OPTION FOR THE PARALLEL CONNECTION OF VOLTAGES With LED recognition the following specification applies: . lmpulse duration: more than 60 µs.; . lmpulse frequency: less than 500 Hz; . Light wavelength: 500 to 960 nm (red). 8 The option includes small resistors to be connected in series to voltage outputs of DRTS 6 and of AMV 66 or AMIV 66 options. Burden is 1 Ohm for tests up to 125 V and 5.7 Ohm for tests at 300 V; at maximum load it causes an error of – 0.5%. - Case: plastic. - Dimensions: 22 x 45 x 85 mm. - Connections to the instrument: two wires 0.2 m long, with safety banana plugs. - Connection to the load: by a safety banana plug. - 125 V or 300 V selection: by switch. DRTS 6 RELAYS, ENERGY METERS AND TRANSDUCERS TEST SET PAI OPTION FOR THE USE AT 30 A, THREE PHASE The option PAI is made of four jumpers, that ease the paralleling of output sockets: I1 and I4; I2 and I5; I3 and I6, and of the two IN sockets: this eases the connection to the relay under test. ORDERING INFORMATION CODE 30156 MAINS SYNCHRONISER The option is made of a plug that fits into the mains, and that has two banana sockets for the connection to the test set counting input. The purpose is to synchronize the outputs of two test sets to the mains: as the synchronisation is repeated every 2 minutes, the test set stays locked to the mains for the infinity. The option includes a circuit that squares the sinusoidal mains waveform; the isolated output is a square-wave with an amplitude of 18 V nominal, running at the mains frequency. There are two instances where the option can be necessary: . Generating a current or voltage into a device that is also taking a signal from the mains; . Synchronising two test sets to the mains, and then using them to test line differential relays. STAND UP SUPPORT The stand-up support allows using the test set in a stand-up position. This is very useful in case of too small room or no support for the test set. There is enough room for the power supply cord, and for the cooling air to flow in. MODULE DRTS 6 6 x I 0...15 A - 4 x V 0...300 V 1 x VDC output 0...260 V at 100 W Standard set of test cables Soft carry bag TDMS - Test & Data Management Software OPTIONAL ACCESSORIES CODE 19153 23156 81156 98156 47156 10161 20162 15156 77156 18156 48156 35150 36156 34156 24156 19170 59156 58156 MODULE Analog AC/DC Measurement Module High Precision (HP) outputs; 0.05% accuracy outputs with SIT laboratory certificate (EU accreditated) IEC61850 Interface, hardware and software IN 2 CDG - Option for High Burden Relays I 100 - 100 A Current Booster GPS syncronizer SH 2003 energy meter universal scanning head Additional set of test cables Heavy duty transport case (Discovery type) Aluminium transport case Soft carrying bag SEI option to put in serie the current outputs PA-I option to put in parallel the current output (3 x 30A) PA-V Mains synchronizer Stand up support Thytronic thysensor cables set ABB zero power cables set APPLICABLE STANDARD The test set conforms to the EEC directives regarding Electromagnetic Compatibility and Low Voltage instruments. A) Electromagnetic Compatibility: Directive 2004/108/EC (CE conform). Applicable standard: EN 61326:2006. B) Low Voltage Directive: Directive 2006/95/EC (CE conform). . Applicable standards, for a class I instrument, pollution degree 2, Installation category II: CEI EN 61010-1. In particular: . Inputs/outputs protection: IP 2X - CEI EN 60529. . Operating temperature: 0°C to 55°C; storage: -25°C to 70°C. . Relative humidity: 5 - 95% without condensing. EXTERNAL AMPLIFIERS CODE MODULE 27156 28156 13156 AMI-99 (3 x I - 0 … 30 A at 160 VA) AMV-66 (2 x V - 0 … 300 V at 80 VA) AMIV-66 (3 x I - 0 … 15 A at 80 VA) (2 x V - 0 … 300 V at 80 VA) OPTIONAL ACCESSORIES FOR EXTERNAL AMPLIFIERS CODE 15156 18156 MODULE Set of testing cables Aluminium Transport Case 9 DRTS 6 10 AMI 99 - External amplifier Heavy duty transport case AMIV 66 - External amplifier Heavy duty transport case in aluminium AMV 66 - External amplifier Soft bag DRTS 6 Optional set of testing cables Standard set of testing cables ISA Srl Via Prati Bassi, 22 21020 Taino VA - Italy Tel +39 0331 956081 Fax +39 0331 957091 Web site: www.isatest.com E-Mail: isa@isatest.com 11 Stand up support EN - DRTS 6 - 06/2014 IN 2 CDG - Option for High Burden Relays The document is subject to change without notice. Always refer to our technical specification for more detailed information and as formal contract document.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : sassib Create Date : 2014:06:11 14:33:45+02:00 Modify Date : 2014:06:11 14:44:39+02:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2014:06:11 14:44:39+02:00 Format : application/pdf Title : DRTS 6 _GB.indd Creator : sassib Producer : Acrobat Distiller 9.5.5 (Windows) Document ID : uuid:a68dff9c-3e9a-4f40-a0f9-4e0ff6160bc4 Instance ID : uuid:aecd7a2b-04db-4b11-ab17-888b371b153f Page Count : 11EXIF Metadata provided by EXIF.tools