http://waterheatertimer.org/Color-codewire2.html#motor
Popular HVAC Motors—Dayton
HP

Frame

Volts

RPM

Rot.

Cap. Req’d

Cradle Base, Single Phase/Split Phase, Fan and Blower Motors, Open Drip-Proof
1/4
48
115
1725
CW/CCW
1/3
48
115
1725
CW/CCW
1/2
48
115
1725
CW/CCW
1/4
48
115/208-230
1725
CW/CCW
1/3
48
115/208-230
1725
CW/CCW
3K771
1/2
48
115/208-230
1725
CW/CCW

Shaft Lng. (In.) Shaft Dia. (In.)

no
no
no
no
no
no

1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2

Item No.

Notes**

1/2*
1/2*
1/2*
1/2*
1/2*
1/2*

3K771
6K778
3K772
3ZP92
3LY10
3LY11

Auto O/L, SB
Auto O/L SB
Auto O/L SB
Auto O/L, BB
Auto O/L, BB
Auto O/L, BB

1/2
1/2
1/2
5/8
5/8

6K438
6K490
6K965
6K376
6K321

Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L BB

5/8
5/8
5/8
5/8

5K115
5K116
5K117
6K148

Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L BB

1/2
1/2
1/2
1/2
1/2
1/2
1/2

4KA21
4KA45
4KA46
4KA41
4KA42
4KA43
4KA44

Auto O/L SP
Auto O/L SP
Auto O/L SP
Auto O/L SP
Auto O/L SP
Auto O/L PSC
Auto O/L PSC

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2

4M261
4M205
4M206
4M207
4M208
4M225
4M226
4M262
4M263

Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L BB
Auto O/L SB
Auto O/L SB
Auto O/L BB
Auto O/L SB

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2

4M096
4M097
4M098
4M099
4M100
4M101
4M183
4M184

Auto O/L SB
Auto O/L SB
Auto O/L SB
Auto O/L SB
Auto O/L SB
Auto O/L SB
Auto O/L SB
Auto O/L SB

1/2
1/2
1/2
1/2

4MA55
4MA57
4MA61
4MA65

Auto O/L RS
Auto O/L RS
Auto O/L RS
Auto O/L RS

5/8
5/8

4MB83
4MB89

Band Stud
Band

*Motors in this section with 1/2 inch shafts are supplied with 5/8 inch bushing adaptor

6K438

5K115

4KA21

4M261

4M096

4MA55
4MB83

Cradle Base, Single Phase/Capacitor Start, Fan and Blower Motors, Open Drip-Proof
1/4
48
115/230
1725
CW/CCW
no
1 1/2
1/3
48
115/230
1725
CW/CCW
no
1 1/2
1/2
48
115/230
1725
CW/CCW
no
1 1/2
3/4
56
115/230
1725
CW/CCW
no
1 7/8
1
56
115/208-230
1725
CW/CCW
no
1 7/8
Rigid Base, Single Phase/Capacitor Start, General Purpose, Open Drip-Proof
1/3
56
115/230
1725
CW/CCW
no
1 7/8
1/2
56
115/230
1725
CW/CCW
no
1 7/8
3/4
56
115/230
1725
CW/CCW
no
1 7/8
1
56H
115/230
1725
CW/CCW
no
1 7/8
Direct Drive Blower, Single Phase/Shaded Pole and Permanent Split Capacitor, Open Air Over (A.O. Smith)
1/8
42Y
115
1050/1
CW/CCW
no
5
1/8
42Y
208-230
1050/1
CW/CCW
no
5
1/5
42Y
115
1050/1
CW/CCW
no
5
1/5
42Y
115
1050/3
CW/CCW
no
5
1/5
42Y
208-230
1050/3
CW/CCW
no
5
1/5
42Y
115
1075/3
CW/CCW
2GE78
5
1/5
42Y
230
1075/3
CW/CCW
2GE78
5
Condenser Fan All Angle, Totally Enclosed, Permanent Split Capacitor (PSC), Stud Mount
1/6
48
208-230
1075
CW/CCW
2GE74
6
1/4
48
208-230
1075
CW/CCW
2GE76
6
1/3
48
208-230
1075
CW/CCW
2GE78
6
1/2
48
208-230
1075
CW/CCW
2GE78
6
3/4
48
208-230
1075
CW/CCW
2GE79
6
1/6
48
208-230
825
CW/CCW
2GE76
6
1/4
48
208-230
825
CW/CCW
2GE76
6
1/3
48
208-230
825
CW/CCW
2GE80
6
1/2
48
208-230
825
CW/CCW
2GE80
6
Residential Direct Drive Blower, Open Air Over, Single Phase PSC (Stud-Ring, Torsion Flex Kits available)
1/4
48
115
1075/3
CW/CCW
2GE76
4
1/4
48
208-230
1075/3
CW/CCW
2GE76
4
1/3
48
115
1075/3
CW/CCW
2GE76
4
1/3
48
208-230
1075/3
CW/CCW
2GE76
4
1/2
48
115
1075/3
CW/CCW
2GE76
4
1/2
48
208-230
1075/3
CW/CCW
2GE76
4
3/4
48
115
1075/3
CW/CCW
2GE81
4
48
208-230
1075/3
CW/CCW
2GE79
4
3/4
Double Shaft Single Phase / PSC OAO (A.O.Smith)
1/6
48
208-230
1075/3
CWLE
2GE76
8-1/2 x 7-1/2
1/4
48
208-230
1075/3
CWLE
2GE76
7-7/8 x 7-1/2
1/3
48
208-230
1075/3
CWLE
2GE76
8-1/8 x 6-3/4
1/2
48
208-230
1075/3
CWLE
2GE78
7-5/8 x 6-3/4
Condenser Fan, Three Phase
1 1/2
56Y
200-230/460
1140
CW/CCW
no
6
2
56Y
200-230/460
1140
CW/CCW
no
6

**Auto O/L: Automatiic Thermal Overload SB: Sleeve Bearing BB: Ball Bearing Band: Band Mount (Belly Band)
Stud: Stud Mount (Thru Bolts) RS: Resilient Ring, Stud Mount SP: Shaded Pole PSC: Permanent Split Capacitor

EPACT Efficient Motors—Dayton
Dayton EPACT Motors –140 Frame through 284T Frame –have a 3 year warranty.
HP

3KW34

Frame

Three Phase, Open Drip-Proof
1/2
56
1
56
1
143T
1 1/2
56H
1 1/2
145T
2
56H
2
145T
3
145T
3
182T
5
184T
7 1/2
213T
10
215T
15
254T

Volts

RPM

Construction

Eff.

Item No.

230 / 460
208-230/460
208-230/460
230/460
208-230/460
230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460

1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800

Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel

81.5%
78.5%
82.5%
85.5%
84.0%
80.0%
84.0%
86.5%
86.5%
87.5%
88.5%
89.5%
91.0%

3N641
3N012
3KW25*
3N644
3KW28*
3N693
3KW31*
2Z276
3KW34*
3KW37*
3KW40*
3KW43*
3KW46*

*Usable on Inverters 10:1 Variable Torque, 2:1 Constant Torque. Usable on 200V with 1.0 SF

Exclusively from Grainger.
There are many ways to get the Dayton products you need–phone, fax, online at www.grainger.com/dayton or
stop by your local Grainger® branch.

(contiued on next page)

EPACT Efficient Motors Continued—Dayton
Dayton EPACT Motors –140 Frame through 286T Frame –have a 3 year warranty.
HP

Frame

Volts

RPM

Construction

Eff.

Item No.

208-230/460

1755

Cast Iron

91.0%

2YB85*

Three Phase, Open Drip-Proof
20

2YB78

256T

25

284T

208-230/460

1760

Cast Iron

91.7%

2YB78*

30

286T

208-230/460

1765

Cast Iron

92.4%

2YB75*

RPM

Construction

Eff.

Item No.
1XTV5*

*Usable on Inverters 10:1 Variable Torque, 3:1 Constant Torque . Usable on 200V with 1.0 SF

NEMA Premium Efficient Motors
NEMA Premium Efficient Motors –have a 3 year warranty.
HP

Frame

Volts

Three Phase, T-Frame, Open Drip-Proof

1XTW9

1

143T

208-230/460

1800

Steel

85.5%

2

145T

208-230/460

1800

Steel

86.5%

1XTV8*

3

182T

208-230/460

1800

Steel

89.5%

1XTW1*

5

184T

208-230/460

1800

Steel

89.5%

1XTW3*

7 1/2

213T

208-230/460

1800

Steel

91.0%

1XTW5*

10

215T

208-230/460

1800

Steel

91.7%

1XTW7*

15

254T

208-230/460

1800

Cast Iron

93.0%

1XTW9*

20

256T

208-230/460

1800

Cast Iron

93.0%

1XTX2*

25

284T

208-230/460

1800

Cast Iron

93.6%

1XTX4*

30

286T

208-230/460

1800

Cast Iron

94.1%

1XTX6*

*Usable on Inverters 10:1 Variable Torque, 4:1 Constant Torque. Usable on 200V with 1.0 SF

Hot Water Circulator Motors—A.O. Smith
HP

RPM

Frame

Split Phase
1/12
1725
48YZ
1/12
1725
48YZ
1/8
1725
48Y
1/8
1725
48YZ
1/6
1725
48YZ
1/6
1725
48YZ
1/6
1725
48YZ
1/6
1725
48YZ
4UB99
1/4
1725
48YZ
1/4
1725
48YZ
1/3
1725
48YZ
Capacitor-start, Capacitor-run

4UE16

Rot.

Volts

Full Load Amps

Item No.

CCWLE
CCWLE
CW/CCW
CCWLE
CCWLE
CCWLE
CWLE
CWLE
CWLE
CCWLE
CWLE

115
115
115
115
115
115
115
115
115
115
115

2.7
2.7
3.1
3.3
4.0
4.0
3.6
3.6
4.6
4.6
5.9

4UB99
4UE10
4UE22
4UE25
4UE11
4UE12
4UE23
4UE24
4UE13
4UE14
4UE15

1/2

1725

56YZ

CW/CCW

115/208-230

5.8/2.8-2.9

4UE16

3/4

1725

56YZ

CW/CCW

115/208-230

8.4/4.2-4.2

4UE18

1/2

1725

56C

CW/CCW

208-230/460

1.8-2.2/1.1

4UE17

3/4

1725

56C

CW/CCW

208-230/460

2.5-2.6/1.3

4UE19

1

1725

56C

CW/CCW

208-230/460

3.4-3.4/1.7

4UE20

1 1/2

1725

56C

CW/CCW

208-230/460

5.7-5.6/2.8

4UE21

Three-Phase

4UE17

Replace Taco, Bell and Gossett, Armstrong and Teel.

Oil Burner Motors—A.O. Smith
HP

RPM

Frame

Rot.

Volts

Full Load Amps

Item No.

1/7

3450

48M

CCWLE

115

2.8

4LY96

1/6

1725

48N

CW/CCW

115

3.2

4MA12

48M

CCWLE

115

1.7

4MA32

Split Phase

4LY96

Permanent Split Capacitor

1/7

3450

4MA32

Exclusively from Grainger.
There are many ways to get the Dayton products you need–phone, fax, online at www.grainger.com/dayton or
stop by your local Grainger® branch.

Run Capacitors—Dayton
Dimensions (In.)

MFD Rating

D

Oval, 370 VAC
3
4
5
6
7.5
10
12.5
2GE74
15

1
1
1
1
1
1
1
1

W

5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16

2
2
2
2
2
2
2
2

H

3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16

EIA UL Base

Item No.

A
A
A
A
A
A
A
A

2GE74
2GE75
2GE76
2GE77
2GE78
2GE79
2GE80
2GE81

2 1/8
2 1/8
2 1/8
2 1/8
2 7/8
2 7/8
2 7/8
3 7/8

V-Belts—Dayton
Nom. Outside
Lng. (In.)

WWG
Stock No.

Nom. Outside
Lng. (In.)

3L Type (3/8" Top width by 7/32" thick)
15
25
3L150
16
26
3L160
17
27
3L170
18
28
3L180
19
29
3L190
20
30
3L200
3L150
21
31
3L210
22
32
3L220
23
33
3L230
24
34
3L240
4L Type (1/2" Top width by 5/16" thick)
17
32
4L170
18
33
4L180
19
34
4L190
20
35
4L200
21
36
4L210
22
37
4L220
23
38
4L230
24
39
4L240
25
40
4L250
4L170
26
41
4L260
27
42
4L270
28
43
4L280
29
44
4L290
30
45
4L300
31
46
4L310

Pulley 1
Diameter

WWG
Stock No.

Nom. Outside
Lng. (In.)

WWG
Stock No.

Nom. Outside
Lng. (In.)

WWG
Stock No.

Nom. Outside
Lng. (In.)

Item No.

3L250
3L260
3L270
3L280
3L290
3L300
3L310
3L320
3L330
3L340

35
36
37
38
39
40
41
42
43
44

3L350
3L360
3L370
3L380
3L390
3L400
3L410
3L420
3L430
3L440

45
46
47
48
49
50
51
52
53
54

3L450
3L460
3L470
3L480
3L490
3L500
3L510
3L520
3L530
3L540

55
56
57
58
59
60
61

3L550
3L560
3L570
3L580
3L590
3L600
3L610

4L320
4L330
4L340
4L350
4L360
4L370
4L380
4L390
4L400
4L410
4L420
4L430
4L440
4L450
4L460

47
48
49
50
51
52
53
54
55
56
57
58
59
60
61

4L470
4L480
4L490
4L500
4L510
4L520
4L530
4L540
4L550
4L560
4L570
4L580
4L590
4L600
4L610

62
63
64
65
66
67
68
69
70
71
72
73
74
75
76

4L620
4L630
4L640
4L650
4L660
4L670
4L680
4L690
4L700
4L710
4L720
4L730
4L740
4L750
4L760

77
78
79
80
82
84
86
88
90
92
94
96
98
100

4L770
4L780
4L790
4L800
4L820
4L840
4L860
4L880
4L900
4L920
4L940
4L960
4L980
3X543

BELT LENGTH FORMULA

(d)

exact
approximate

L = 2C + 1.57 (D - d) +
Pulley 2
Diameter

Center
Distance

(D)

(C)

(D - d)2
4C

L = Pitch Length of Belt
C = Center Distance
D = Pitch Diameter of Large Sheave
d = Pitch Diameter of Small Sheave

Dayton V-belts interchange with major
brands like Browning, Goodyear, Gates,
Dayco, and others. Lengths are matched
to RMA (Rubber Manufacturers’
Association) standards.

Accessories - Brackets­— Dayton
Description

Item No.

Mounting Lug Brackets
3LC31
3M133

Double Wire Bracket
Band Mount Bracket
Fits blower wheel Dia. (In.)

Bracket

3LC31

Fits NEMA Frame (Motor Size)

Item No.

42/48

5X247

Motor Mounting Brackets for 9-12" Dia. Blower Housings
9 or 10

Torsion Flex

9

Welded Ring

42

3M146

10

Welded Ring

48

3M147

Exclusively from Grainger.
There are many ways to get the Dayton products you need–phone, fax, online at www.grainger.com/dayton or
stop by your local Grainger® branch.

5X247

3M146

HOW TO REPLACE A MOTOR

Ideally, you should replace like for like, but that may not be always possible. Here are some basics:

Matching Data Needed:

There are four types of single phase motors:

HP = Horsepower

1. Shade Pole

RPM = Rotations Per Minute—Sometimes listed as “number of poles”.

2. Permanent Split Capacitor (PSC)

Ph = Phase—For AC motors the choice is “single” or “three” phase

3. Split Phase

Volts or V = Voltage—Common AC Voltages are 115/200/208/230/460

4. Capacitor Start

Fr = Frame—Examples include: 48 / 56/ 145T etc.

Need More Help?

SF = Service Factor—Common SF = 1.0 / 1.15 / 1.25 / 1.35

n I f

you have a manufacturer part number, you can go to
grainger.com and enter it to find a replacement motor.

Encl = Enclosure—Basic enclosures are “Open” or “Totally Enclosed”.

n I f

you have just the specifications, you can use the Motor Selection
Guide on Grainger.com to find a replacement motor.

Rules of Thumb for Motor Replacement:
1. In HVAC, you can often move up to the next HP or move up in
Service Factor.

n Y
 ou

can also get more of what you need in the Grainger catalog 399:
V-belts: Pgs 153-156
Sheaves: Pgs 164
Capacitors: Pgs 90
Accessories: Pgs 91-95

2. Matching Amperage can be helpful in estimating HP.
3. Ball and sleeve bearing motors can be inter-changeable, but ball
bearing may be noisier.
4. Motors can normally run up to 10% above and below rated voltage.

n R
 emember:

The first nine pages of the Grainger catalog are a great
resource for motor data!

5. You should not interchange “Manual Overload” with an “Automatic
Overload” motor protector.
6. You can vary the speed of a PSC (Permanent Split Capacitor), but not
of a Split Phase or Capacitor Start Motor.
7. You can move up in “Starting” or “Run Torque”, when replacing a
motor. (e.g.: Cap Start can replace a Split Phase; PSC can replace
Shaded Pole.)
8. Motor Frame Diameter can be helpful in determining frame size.
9. TEAO or OAO enclosed motors need to be mounted in the air stream
of the fan they are running.

Speed in RPM

Motor Frame Data:
No Load Speed

Running or Name Plate
Speed Range

Frame

Approx. Frame
Diameter

Approx. Shaft
Height

NOTES

RPM

RPM

3.3

3.3 inch

1 1/2

Mostly Shaded Pole

2

3600

3000-3600

4

4 inch

2

Mostly Shaded Pole and PSC

4

1800

1400-1800

42

5 inch

2 5/8

Mostly Shaded Pole and PSC

6

1200

950-1200

48

5 .5 inch

3

Mostly PSC and Split Phase

8

900

800-900

Poles

56

6.5 inch

3 1/2

Mostly Cap Start and 3 phase

56H

6.5 inch

3 1/2

Mostly Cap Start and 3 phase

140 T

6.5 inch

3 1/2

Mostly 3 phase

A, Y Suffix to a frame designation means non standard mounting (i.e.: 48Y)
A, Z Suffix means a non standard shaft (i.e.: 48Z)

Enclosures
Abbreviation

Definition

Description

OP

Open

Holes in motor shell

ODP

Open drip-proof

Bottom half of motor open (water will flow out)

AO/OAO

Air over/Open air over

Fan air blows directly over motor

TE

Totally enclosed

No holes anywhere in motor shell

TEAO

Totally enclosed air over

Fan air blows directly over motor

TENV

Totally enclosed non-vented

Excess heat is radiated through the body of the motor

TEFC

Totally enclosed fan-cooled

Has an external fan covered by a housing

EXP-PRF

Explosion proof

Will withstand an explosion of a gas, vapor or dust, which may occur within it

*Air-Over motors (AO, OAO and TEAO) must have air blowing over them continuously while in operation.

Motor Dimensional Chart—All Dimensions in Inches
NEMA FRAME

D*

2E

2F

BA

H

N-W

U

V§ Min.

Wide

Key Thick

Long

42

2 5/8

3½

1 11/16

2 1/16

9/32 slot

1 1/8

3/8

--

--

3/64 flat

--

48

3

4¼

2¾

2½

11/32 slot

1 1/2

1/2

--

--

3/64 flat

--

48H

3

4¼

4¾

2½

11/32 slot

1 1/2

1/2

--

--

3/64 flat

--

56

3½

4 7/8

3

2¾

11/32 slot

1 7/8 †

5/8 †

--

3/16 †

3/16 †

1 3/8 ‡

56H

3½

4 7/8

3&5‡

2¾

11/32 slot

1 7/8 †

5/8 †

--

3/16 †

3/16 †

1 3/8 †

56HZ

3½

**

**

**

**

2 1/4

7/8

2

3/16

3/16

1 3/8

66

4 1/8

5 7/8

5

3 1/8

13/32 slot

2 1/4

3/4

--

3/16

3/16

1 7/8

143T

3½

5½

4

2¼

11/32 dia.

2 1/4

7/8

2

3/16

3/16

1 3/8

145T

3½

5½

5

2¼

11/32 dia.

2 1/4

7/8

2

3/16

3/16

1 3/8

182

4½

7½

4½

2¾

13/32 dia.

2 1/4

7/8

2

3/16

3/16

1 3/8

184

4½

7½

5½

2¾

13/32 dia.

2 1/4

7/8

2

3/16

3/16

1 3/8

182T

4½

7½

4½

2¾

13/32 dia.

2 3/4

1 1/8

2 1/2

1/4

1/4

1¾

184T

4½

7½

5½

2¾

13/32 dia.

2 3/4

1 1/8

2 1/2

1/4

1/4

1¾

213

5¼

8½

5½

3½

13/32 dia.

3

1 1/8

2 3/4

1/4

1/4

2

215

5¼

8½

7

3½

13/32 dia.

3

1 1/8

2 3/4

1/4

1/4

2

213T

5¼

8½

5½

3½

13/32 dia.

3 3/8

1 3/8

3 1/8

5/16

5/16

2 3/8

215T

5¼

8½

7

3½

13/32 dia.

3 3/8

1 3/8

3 1/8

5/16

5/16

2 3/8

254#

6¼

10

8¼

4¼

21/32 dia.

3 3/8

1 1/8

3 1/8

1/4

1/4

2 3/8

254U

6¼

10

8¼

4¼

17/32 dia.

3 3/4

1 3/8

3 1/2

5/16

5/16

2¾

256U

6¼

10

10

4¼

17/32 dia.

3 3/4

1 3/8

3 1/2

5/16

5/16

2¾

254T

6¼

10

8¼

4¼

17/32 dia.

4

1 5/8

3 3/4

3/8

3/8

2 7/8

256T

6¼

10

10

4¼

17/32 dia.

4

1 5/8

3 3/4

3/8

3/8

2 7/8

284#

7

11

9½

4¾

21/32 dia.

3 3/4

1 1/4

3 1/2

1/4

1/4

2¾

284U

7

11

9½

4¾

17/32 dia.

4 7/8

1 5/8

4 5/8

3/8

3/8

3¾

286U

7

11

11

4¾

17/32 dia.

4 7/8

1 5/8

4 5/8

3/8

3/8

3¾

284T

7

11

9½

4¾

17/32 dia.

4 5/8

1 7/8

4 3/8

1/2

1/2

3¼

286T

7

11

11

4¾

17/32 dia.

4 5/8

1 7/8

4 3/8

1/2

1/2

3¼

(*) Dimension “D” will never be greater than the above values on
rigid mount motors, but it may be less so that shims up to 1/32"
thick (1/16" on 364U and 365U frames) may be required for
certain machines.

(§) Dimension “V” is shaft length available for coupling, pinion or
pulley hub—this is a minimum value.

(‡) Designated 56H motors have two sets of 2F mounting
holes—3" and 5".

More frame dimensions available on
pages 4 thru 6 of the Grainger Catalog
or on grainger.com

(#) Discontinued NEMA frame.
(**) Base of Dayton 56HZ frame motors has holes and slots to
match NEMA 56, 56H and 145T mounting dimensions.
(†) Certain NEMA 56Z frame motors have 1/2" dia. x 11/2" long
shaft with 3/64" flat. These exceptions are noted in this catalog.

Exclusively from Grainger.
There are many ways to get the Dayton products you need–phone, fax, online at www.grainger.com/dayton or
stop by your local Grainger® branch.

(§§) The 2F dimension is 20.

Water System Pumps—Bell & Gossett—Bronze Circulating Pumps
Total Ft. of Head @ GPM +
3
4
5
6
7
8
9
10
12
15
18
20
25
30
40
50
60
70
80
90
100 110 Best Efficiency
GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM @ Head Ft.

Item No.

Wet Rotor Circulators
11

10

9

8

7

7

6

5

3

1

—

—

—

—

—

—

—

—

—

—

—

—

7 GPM @ 7

4RD11

13

12

12

11

10

10

9

8

7

5

3

2

—

—

—

—

—

—

—

—

—

—

10 GPM @ 8

4RD06

13

12

12

11

10

10

9

8

7

5

3

2

—

—

—

—

—

—

—

—

—

—

10 GPM @ 8

4RD05

19

18

17.5

17

15

13

12

10

5

—

—

—

—

—

—

—

—

—

15 GPM @ 13

4JA87

Maintenance Free Series PL™
23

22

21

20

36

35

34

33

32

31.5

31

30

27

26

24

22

17.5

12.5

—

—

—

—

—

—

—

—

20 GPM @ 22

4JA88

29

28.5

28

27

26.5

26

25.5

25

24.5

23.5

22.5

21

17.5

15

7.5

—

—

—

—

—

—

—

25 GPM @ 18

4JA89

17.5

17

17

16.5

16

16

15.5

15.5

15.5

15.5

15

15

14

12.5

10

5

—

—

—

—

—

—

35 GPM @ 12

4JA90

Three-Piece Oil-Lubricated Booster Pumps
*

*

8

8

8

7

7

7

7

7

6

5

4

2

—

—

—

—

—

—

—

—

17 GPM @ 6

4RD17

*

*

12

12

12

12

12

12

11

11

11

10

10

7

—

—

—

—

—

—

—

—

28 GPM @ 8

4RC94

*

*

17

17

16

16

16

16

15

14

13

12

6

—

—

—

—

—

—

—

—

—

18 GPM @ 12

4RC92

*

*

10

10

10

10

10

10

10

10

10

10

10

9

8

6

4

2

—

—

—

—

40 GPM @ 8

4RC96

*

*

16

15

15

15

15

15

15

15

15

14

14

14

13

12

11

9

8

6

4

—

65 GPM @ 11

4RC98

18

17

15

12

—

—

—

—

—

—

36 GPM @ 16

5YN66

Maintenance Free Series 60
*

*

*

*

*

*

*

19

19

19

19

19

*

*

*

*

*

*

*

*

24

24

24

24

24

24

23

21

19

16

13

—

—

—

52 GPM @ 20

5YN67

*

*

*

*

*

*

*

*

*

*

*

*

24

24

24

23

23

22

21

20

19

18

85 GPM @ 21

5YN69

(*) Operation of pump in this range will result in reduced pump life and/or motor damage. (+) To convert to psi, divide total feet of head by 2.31.

4RD11

HP

Volts

4JA87

Phase

FLA

4RD17

Thermal Protection

Face to Face

5YN66
Dimensions (In.)
W

Inlet & Outlet

L

Flange
Included

Item
No.

Wet Rotor Circulators
1/40

115

1

0.48

Impedance

6 1/8

4 7/8

4 7/8

Union

No

4RD11

1/25

115

1

0.8

Impedance

6 3/8

4 7/8

4 7/8

Union

No

4RD06

1/25

115

1

0.8

Impedance

6 1/8

4 7/8

5 5/8

Flanged

No

4RD05

1

1.4

Auto

6 3/8

4 3/8

8 5/8

Flanged

No

4JA87

Maintenance Free Series PL™
1/12

115

1/6

115

1

2.1

Auto

6 3/8

4 3/8

8 5/8

Flanged

No

4JA88

1/6

115

1

2.1

Auto

8 1/2

4 1/2

9 1/8

Flanged

No

4JA89

1/6

115

1

1.8

Auto

8 1/2

4 1/2

9 1/8

Flanged

No

4JA90

5 1/4

14 7/8

Flanged

No

4RD17
4RC94

Three-Piece Oil-Lubricated Booster Pumps
1/12

115

1

1.75

Auto

6 3/8

1/6

115

1

1.9

Auto

8 1/2

6 1/2

15 3/8

Flanged

No

1/6

115

1

1.9

Auto

8 1/2

7 1/16

15 1/4

Flanged

No

4RC92

1/6

115

1

1.9

Auto

8 1/2

6 11/16

16 5/8

2" Flg

Yes

4RC96

1/4

115

1

3

Auto

10

7 9/16

17 1/4

2 1/2" Flg

Yes

4RC98

2.8/1.4

Auto

11

7 1/2

19 7/8

1.25" Flg

Yes

5YN66

Maintenance Free Series 60
1/4

115/208-230

1

1/2

115/208-230

1

5/2.5

Auto

11 1/2

7 7/8

21 7/16

1.5" Flg

Yes

5YN67

3/4

115/208-230

1

7.2/3.6

Auto

11 1/2

8

21 11/16

2" Flg

Yes

5YN69

Note: For use only with nonflammable liquids compatible with pump component materials.

Exclusively from Grainger.
There are many ways to get the Dayton products you need–phone, fax, online at www.grainger.com/dayton or
stop by your local Grainger® branch.

Seal Bearing Assemblies and Graduated Oil Tubes—Bell & Gossett
Key

Fits Pump Nos.

Item No.

A

4RD16

4RD83*

A

4RD17

4RD79*

Seal Bearing Assemblies

A

4RC93, 4RC95, 4RC94, 4RC96

4RD82

A

4RC91, 4RC97, 4RC99, 4RD02, 4RC92, 4RC98, 4RD01, 4RD03

4RD80

B

4RD13, 4RD14

4RD78

C

4RD15

4RD75

C

1R247, 1R470

4YM28

D

5YN64, 5YN65, 5YN66, 5YN67, 5YN68, 5YN69, 5YN70, 5YN71, 5YN72

5YN79

D

5YN73, 5YN74, 5YN75, 5YN76, 5YN77

5YN80

4RD83

4RD78

Graduated Oil Tubes
— Used with Nos. 4RC91-99, 4RD02, 4RD16, and 4RD17. 1 1⁄2 oz.

4YM22

— Used with Nos. 4RD13-14 and 4RD35-46. 2 1⁄2 oz.

4YM23

(*) Comes with impeller.

Circulating Pump Couplers—Bell & Gossett
Key

Fits Shaft Size (In.)

Coupling Material

Item No.

A

4RD16, 4RC93, 4RC95, 4RC91, 4RD17, 4RC94, 4RC92, 4RC96

Fits Pump Nos.

1/2 x 1/2

Cast-Iron

4RD81

A

4RC97, 4RC99, 4RD02, 4RC98, 4RD01, 4RD03

1/2 x 1/2

Cast-Iron

4RD27

A

4RD13, 4RD14, 5YN65, 5YN64, 5YN71, 5YN68, 5YN72, 5YN66, 5YN67, 5YN69

1/2 x 1/2

Cast-Iron

4RD26

A

4RD41, 4RD42, 5YN70, 5YN75, 5YN73

5/8 x 1/2

Cast-Iron

4RD77

A

4RD13, 4RD14

5/8 X 1/2

Cast-Ir./Spring

4YM24

B

4RD41, 4RD42, 4RD43, 5YN76

5/8 x 5/8

Steel/Rubber

4RD76

B

5YN77, 5YN74

5/8 x 5/8

Steel/Rubber

4YM27

B

5YN75, 5YN76

5/8 X 1/2

Zinc/Rubber

5YN78

4RD81

4RD76

Accessories for Bronze In-Line Pumps—Bell & Gossett
Fits Pump Nos.

Item No.

Motor Mount Rings for In-Line Circulator Pumps
4RD16, 4RC93, 4RC95, 4RD17, 4RC94, 4RC96, 4RC91, 4RC92

4RD24

4RC97, 4RC99, 4RD02, 4RD13, 4RD14, 4RC98, 5YN65, 5YN66,5YN64, 5YN71, 5YN67, 5YN70, 5YN68, 5YN72, 5YN69

4RD25

4RD24

Accessories for Bronze In-Line Pumps—Bell & Gossett
Pipe Size (In.)

Used with Pump Nos. No.

Item No.

Bronze Union Connections
1/2 Sweat

4RD08, 4RD11, 4RD06

4RD20

3/4 Sweat

4RD08, 4RD11, 4RD06

4RD18

3/4 NPT

4RD08, 4RD11, 4RD06

4RD19
4RD20

Bronze Flanges, Set of 2
3/4

4JA87, 4JA88, 4RD05, 4PD11, 4RD17, 4RC92, 5P428, 5P433, 4P977

4RC84

1

4JA87, 4JA88, 4RD05, 4PD11, 4RD17, 4RC92, 5P428, 5P433, 4P977

4RC85

1 1/4

4JA87, 4JA88, 4RD05, 4PD11, 4RD17, 4RC92, 5P428, 5P433, 4P977

4RC86

1 1/2

4JA87, 4JA88, 4RD05, 4PD11, 4RD17, 4RC92, 5P428, 5P433, 4P977

4RC87

1

4RC94, 4PC79, 4JA89, 4JA90

4RC88

1 1/4

4RC94, 4PC79

4RC89

1 1/2

4RC94, 4PC79

4RC90

TC-1 Timer

4RD11, 4RD05, 4RD06

4RD21

1/2" Aquastat

4RD11, 4RD05, 4RD06

4RD22

3/4" Aquastat

4RD11, 4RD05, 4RD06

4RD23

4RC84

Accessories
4RD21



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseThumbs
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Create Date                     : 2008:01:08 13:59:40-06:00
Metadata Date                   : 2011:07:12 15:27:01-05:00
Modify Date                     : 2011:07:12 15:27:01-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.1)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 18570 bytes, use -b option to extract)
Instance ID                     : uuid:49cab2ea-e68b-462f-913b-bd430634ff6f
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:35e8f73b-aed5-11dc-b599-9b659ee28324
Derived From Instance ID        : 35e8f73a-aed5-11dc-b599-9b659ee28324
Derived From Document ID        : adobe:docid:indd:b1892ffd-6cce-11dc-87e7-f426a3b0708b
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:F543959AA97211DCA474BA32C7EB5B89, uuid:3F09DA0071B211DC8A3EEF4EBC3F09B2
Manifest Reference Document ID  : uuid:F5439599A97211DCA474BA32C7EB5B89, uuid:3F09D9FF71B211DC8A3EEF4EBC3F09B2
Format                          : application/pdf
Title                           : Dayton Motor Guide
Description                     : A listing of attributes of different types of Dayton motors, along with a guide on how to replace a motor.
Creator                         : grainger.com
Subject                         : Dayton, motors, hvac, EPACT Efficient, NEMA Premium Efficient, Hot Water Circulator, oil burner, run capacitors, v-belts
Page Count                      : 7
Page Layout                     : SinglePage
Author                          : grainger.com
Keywords                        : Dayton, motors, hvac, EPACT Efficient, NEMA Premium Efficient, Hot Water Circulator, oil burner, run capacitors, v-belts
EXIF Metadata provided by EXIF.tools