PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
A Series CW Series
C Series
INDEX
Description Page
A Series Units
49
C Series Units
51
CW Series Units
53
Page 47
Page 48
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
A Series Units
A1 thru A8 Pump/Motor A21 thru A27 Pump/Motor
“A” Series pump/motor combinations are high quality pre-engineered packages designed to satisfy medium service,
steady load and/or intermittent duty applications: hi-flow, low pressure, lube transfer, recirculation, scavenge and filtration.
As shown below, a variety of performance characteristics are available through the combination of several pump
configurations with single and/or three phase TEFC heavy-duty ball bearing motors. All combinations are bi-directional.
The pumps, also available separately, feature high strength cast iron bodies with precision machined internal trapping
grooves, hardened alloy gears and shafts, leaded bronze sleeve bearings and Buna-N seals and o-rings to provide long,
quiet, trouble-free performance.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Pump A1 A2 A4 A6 A8 A21 A23 A25 A27
Motor .00028 GPR .00047 GPR .00081 GPR .00137 GPR .00202 GPR .00178 GPR .00304 GPR .00425 GPR .00633 GPR
A154 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM 3.0 GPM 5.3 GPM 7.4 GPM 10.9 GPM
½ HP .1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI 225 PSI 150 PSI 100 PSI 75 PSI
1 PHASE TEFC A1+A154 A2+A154 A4+A154 A6+A154 A8+A154 A21+A154 A23+A154 A25+A154 A27+A154
A354 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM 3.0 GPM 5.3 GPM 7.4 GPM 10.9
½ HP .1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI 225 PSI 150 PSI 100 PSI 75 PSI
3 PHASE TEFC A1+A354 A2+A354 A4+A354 A6+A354 A8+A354 A21+A354 A23+A354 A25+A354 A27+A354
A174 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM 3.0 GPM 5.2 GPM 7.3 GPM 11.0 GPM
¾ HP .1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI 350 PSI 200 PSI 150 PSI 100 PSI
1 PHASE TEFC A1+A174 A2+A174 A4+A174 A6+A174 A8+A174 A21+A174 A23+A174 A25+A174 A27+A174
A374 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM 3.0 GPM 5.2 GPM 7.3 GPM 11.0 GPM
¾ HP .1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI 350 PSI 200 PSI 150 PSI 100 PSI
3 PHASE TEFC A1+A374 A2+A374 A4+A374 A6+A374 A8+A374 A21+A374 A23+A374 A25+A374 A27+A374
A1104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM 2.9 GPM 5.2 GPM 7.3 GPM 11.0 GPM
1 HP .1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI 475 PSI 275 PSI 200 PSI 125 PSI
1 PHASE TEFC A1+A1104 A2+A1104 A4+A1104 A6+A1104 A8+A1104 A21+A1104 A23+A1104 A25+A1104 A27+A1104
A3104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM 2.9 GPM 5.2 GPM 7.3 GPM 11.0 GPM
1 HP .1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI 475 PSI 275 PSI 200 PSI 125 PSI
3 PHASE TEFC A1+A3104 A2+A3104 A4+A3104 A6+A3104 A8+A3104 A21+A3104 A23+A3104 A25+A3104 A27+A3104
A1154 1.17 GPM 2.18 GPM 3.34 GPM 2.8 GPM 5.1 GPM 7.2 GPM 10.9 GPM
1½ HP .1725 RPM 1550 PSI 925 PSI 625 PSI 70 PSI 425 PSI 300 PSI 200 PSI
1 PHASE TEFC A4+A1154 A6+A1154 A8+A1154 A21+A1154 A23+A1154 A25+A1154 A27+A1154
A3154 1.17 GPM 2.18 GPM 3.34 GPM 2.8 GPM 5.1 GPM 7.2 GPM 10.9 GPM
1½ HP .1725 RPM 1550 PSI 925 PSI 625 PSI 700 PSI 425 PSI 300 PSI 200 PSI
3 PHASE TEFC A4+A3154 A6+A3154 A8+A3154 A21+A3154 A23+A3154 A25+A3154 A27+A3154
Page 49
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
A1 thru A8 Pump/Motor
A21 thru A27 Pump/Motor
Pump Part No.A1A2A4A6A8A21A23A25A27
Dim. "D" 2.482.572.743.023.344.244.544.765.32
Motor Part No. A154 A354 A174 A374 A1104 A3104 A1154 A3154
Dim. "A" 9.62 9.00 1.62 10.50 11.25 10.00 12.25 10.00
Note: Motor and Bracket dimensions subject to change due to availability of inventory.
Performance Data
Page 50
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
C Series Units
C1 thru C8 Pump/Motor Combinations
All “C” Series pump/motor units are bi-directional. The precision alignment of the motor to “C” Series is assured by a
machined adaptor bracket. The ½ to 1 ½ H.P. electric motors are frame 56, continuous duty, ball-bearing, totally
enclosed, fan cooled units of the highest quality. The motors are offered as standard in either single phase 115, 230 volt,
1750 RPM, or 208 , 230, 460 volt, 1750 RPM, 50/60 cycle.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Pump C1 C2 C4 C6 C8
Moto
r
.00028 GPR .00047 GPR .00081 GPR .00137 GPR .00202 GPR
C154 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
½ HP .1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
1 PHASE TEFC C1+C154 C2+C154 C4+C154 C6+C154 C8+C154
C354 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
½ HP .1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
3 PHASE TEFC C1+C354 C2+C354 C4+C354 C6+C354 C8+C354
C174 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
¾ HP .1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
1 PHASE TEFC C1+C174 C2+C174 C4+C174 C6+C174 C8+C174
C374 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
¾ HP .1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
3 PHASE TEFC C1+C374 C2+C374 C4+C374 C6+C374 C8+C374
C1104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 HP .1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
1 PHASE TEFC C1+C1104 C2+C1104 C4+C1104 C6+C1104 C8+C1104
C3104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 HP .1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
3 PHASE TEFC C1+C3104 C2+C3104 C4+C3104 C6+C3104 C8+C3104
C1154 1.17 GPM 2.18 GPM 3.34 GPM
1½ HP .1725 RPM 1550 PSI 925 PSI 625 PSI
1 PHASE TEFC C4+C1154 C6+C1154 C8+C1154
C3154 1.17 GPM 2.18 GPM 3.34 GPM
1½ HP .1725 RPM 1550 PSI 925 PSI 625 PSI
3 PHASE TEFC C4+C3154 C6+C3154 C8+C3154
Page 51
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
Pump Part C1 C2 C4 C6 C8
Dim. "D" 2.48 2.57 2.74 3.02 3.34
Motor Part C154 C354 C174 C374 C1104 C3104 C1154 C3154
Dim. "A" 9.62 9.25 10.62 10.50 11.25 10.00 12.25 10.25
Note: Motor and Bracket dimensions subject to change due to availability of inventory.
Performance Data
Page 52
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
CW Series Units
CW21 thru CW27 Pump/Motor Combination CW41 thru CW49 Pump/Motor Combination
All “CW” Series pump/motor units are bi-directional. The precision alignment of the motor to “CW” Series is assured by a
machined adaptor bracket. The 3 to 20 H.P. electric motors are frame 182TC to 256TC, continuous duty, ball-bearing,
totally enclosed, fan cooled units of the highest quality. The motors are offered as standard in either three phase 115, 230
volt, 1750 RPM, or 208, 230, 460 volt, 1750 RPM, 50/60 cycle.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Motor
(All 1750 RPM, CW21 CW23 CW25 CW27 CW41 CW43 CW45 CW47 CW49
3
Ph
ase,
TEFC)
.
001
7
8
GPR
.
00304
GPR
.
0042
5
GPR
.
00633
GPR
.
0068
GPR
.
0102
GPR
.
0132
GPR
.
0169
GPR
.
0192
GPR
3304 CW21-3304 CW23-3304 CW25-3304 CW27-3304 CW41-3304 CW43-3304 CW45-3304 CW47-3304 CW49-3304
3 HP 2.4 GPM 4.8 GPM 7.1 GPM 10.8 GPM 11.4 GPM 17.2 GPM 22.5 GPM 28.8 GPM 32.8 GPM
182TC
F
rame
1400
PSI
82
5
PSI
600
PSI
400
PSI
3
75
PSI
2
5
0
PSI
200
PSI
1
5
0
PSI
12
5
PSI
3504 CW21-3504 CW23-3504 CW25-3504 CW27-3504 CW41-3504 CW43-3504 CW45-3504 CW47-3504 CW49-3504
5 HP 2.1 GPM 4.5 GPM 6.6 GPM 10.3 GPM 11.2 GPM 17.0 GPM 22.2 GPM 28.4 GPM 32.5 GPM
184TC
F
rame
23
5
0
PSI
13
75
PSI
1000
PSI
6
5
0
PSI
62
5
PSI
400
PSI
32
5
PSI
2
5
0
PSI
22
5
PSI
3754 CW23-3754 CW25-3754 CW27-3754 CW41-3754 CW43-3754 CW45-3754 CW47-3754 CW49-3754
7 ½ HP 4.1 GPM 6.2 GPM 10.2 GPM 11.0 GPM 16.9 GPM 22.0 GPM 28.2 GPM 32.3 GPM
213TC
F
rame
20
5
0
PSI
14
75
PSI
1000
PSI
92
5
PSI
62
5
PSI
4
75
PSI
3
75
PSI
32
5
PSI
31004 CW25-31004 CW27-31004 CW41-31004 CW43-31004 CW45-31004 CW47-31004 CW49-31004
10 HP 6.0 GPM 9.9 GPM 10.9 GPM 16.8 GPM 21.8 GPM 28.0 GPM 32.0 GPM
215TC
F
rame
1875
PSI
1325
PSI
1225
PSI
825
PSI
625
PSI
500
PSI
425
PSI
31504 CW41-31504 CW43-31504 CW45-31504 CW47-31504 CW49-31504
15 HP 9.7 GPM 16.5 GPM 21.0 GPM 27.9 GPM 31.8 GPM
254TC
F
rame
1850
PSI
1225
PSI
950
PSI
750
PSI
650
PSI
32004 CW43-32004 CW45-32004 CW47-32004 CW49-32004
20 HP 16.25 GPM 19.8 GPM 27.8 GPM 31.6 GPM
256TC Frame
16
5
0
PSI
12
75
PSI
1000
PSI
8
75
PSI
Pump
Page 53
PUMP AND MOTOR COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
CW21 thru CW27 Pump/Motor Combinations
CW41 thru CW49 Pump/Motor Combinations
A
BCDEFGH I JKLM M
N
P
R
S
3304 13.139.47 - 7.194.735.693.759.237.252.255.503.383.87 CW21 0.63 3.2 1.75 - 3/4 NPTF (2)
3504 14.139.47 - 7.194.735.693.759.237.752.756.503.383.87 CW23 0.63 3.5 1.75 - 3/4 NPTF (2)
3754 15.81 10.86 - 8.66 5.43 6.66 4.25 10.69 8.56 2.75 6.50 4.00 4.34 CW25 0.63 3.78 1.75 - 3/4 NPTF (2)
31004 17.31 10.86 - 8.66 5.43 6.66 4.25 10.69 9.31 3.25 8.00 4.00 4.34 CW27 0.63 4.27 1.75 - 3/4 NPTF (2)
31504 18.91 12.56 1.56 9.44 6.28 7.44 5.00 12.56 9.78 4.13 9.50 4.50 5.09 CW41 0.91 5.41 4.22 5.38 1 1/4 NPTF (2)
32004 20.66 12.56 1.56 9.44 6.28 7.44 5.00 12.56 10.66 5.00 11.25 4.50 5.09
CW43
0.91
5
.
72
4
.
59
5
.
38
1
1/4
NPTF
(2)
CW45 0.91 6.06 4.94 5.38 1 1/4 NPTF (2)
Note: Motor and Bracket dimensions subject to change due to availability of inventory. CW47 0.91 6.47 5.41 5.38 1 1/4 NPTF (2)
CW49
0
.
91
6
.
72
5
.
59
5
.
38
1
1/4
NPTF
(2)
Pump
Model
Dimensions
MOTOR
MODEL
Dimensions
Performance Data
Page 54
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
B Series CT Series
BCV Series
INDEX
Description Page
B Series Units
57
CT and CX Series Units
59
BCV Series Units
61
Page 55
Page 56
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
B Series Power Packages
B Series Power Unit with 1 Gallon Tank B Series Power Unit with 5 Gallon Tank
.
With the 1, 1 ½ or 2 ½ gallon tank and TEFC 56 frame motors, B models are one of the most compact, utilized power
packages available today. The 1 and 1 ½ gallon tank unit includes a custom heat dissipating aluminum tank and an
externally adjustable relief valve. Units can be mounted horizontally (foot down) or vertically (tank down). TEFC motors
are 56 frame specially configured for Delta Power B units, 4 pole motors run at the highly desirable speed of 1725 RPM
rather than the 3450 version normally used on competitor’s units.
While each unit is a complete power unit, their scope is radically increased by adapting to valve accessories like
85005677 found in section 9 of this catalog. Please refer to Section 9 for other adaptations.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump B1 B2 B4 B6 B8
Moto
r
.00028 GPR .00047 GPR .0081 GPR .00137 GPR .00202 GPR
B154 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
1 Phase TEFC B1+B154 B2+B154 B4+B154 B6+B154 B8+B154
B354 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
3 Phase TEFC B1+B354 B2+B354 B4+B354 B6+B354 B8+B354
B174 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
1 Phase TEFC B1+B174 B2+B174 B4+B174 B6+B174 B8+B174
B374 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
3 Phase TEFC B1+B374 B2+B374 B4+B374 B6+B374 B8+B374
B1104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
1 Phase TEFC B1+B1104 B2+B1104 B4+B1104 B6+B1104 B8+B1104
B3104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
3 Phase TEFC B1+B3104 B2+B3104 B4+B3104 B6+B3104 B8+B3104
B1154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
1 Phase TEFC B4+B1154 B6+B1154 B8+B1154
B3154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
3 Phase TEFC B4+B3154 B6+B3154 B8+B3154
B3204 2.06 GPM 3.26 GPM
2 H.P. 1725 RPM 1225 PSI 850 PSI
3 Phase TEFC B6+B3204 B8+B3204
B3304 1.90 GPM 3.12 GPM
3 H.P. 1725 RPM 1850 PSI 1250 PSI
3 Phase TEFC B6+B3304 B8+B3304
Intermittent Duty
Caution: Relief valves must be set prior to installation. They are not factory
preset. Relief valves will include springs which will allow relief valves settings to
the pressures indicated on the chart.
B6+B174 Pump/Motor/1 Gal. Tank
To order Power unit with 1-1/2 gallon tank, specify as follows
B6+B174-1-1/2 TK Pump/Motor/1-1/2 Gal. Tank
To order Power unit with 2-1/2 gallon tank, specify as follows
B6+B174-2-1/2 TK Pump/Motor/2-1/2 Gal. Tank
To order Power unit with 5 gallon tank, (add letter T), as follows
BT6+B174 Pump/Motor/5 Gal. Tank
To order Power unit with 5 gallon tank, (add letter X), as follows
BX6+B174 Pump/Motor/10 Gal. Tank
Page 57
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
B Series Power Unit with 1 Gallon Tank
A
BCE
B154 11.13 19.69 19.38 9.88
B354 10.50 19.06 18.75 9.25
B174 12.00 19.06 18.75 10.75
B374 10.50 19.06 18.75 9.25
B1104 12.13 20.69 20.38 10.88
B3104 11.13 19.56 19.25 9.88
B1154 13.01 21.06 20.75 11.76
B3154 11.00 19.56 19.25 9.75
B3204 12.13 20.69 20.38 10.88
B3304 13.00 21.44 21.13 11.75
Dimension
MOTOR
Note: Motor dimensions are approximate
dependent on current availability
B Series Power Unit with 5 Gallon Tank Ordering - Service Parts
Performance Data
Page 58
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
CT and CX Series Power Packages
Pump motor combinations are offered with 5 or 10 gallon tanks to form complete hydraulic power packages. When
ordering, specify pump, motor, and tank sizes. Adding a “T” to the model numbers of pump and motor in the chart
designates a 5 gallon tank. Using an “X” in the number instead of the “T”, designates a 10 gallon tank. For example, CT6
+ C354 would specify a complete unit: pump C6, motor size C354, 5 gallon tank “T”. To order a 10 gallon tank
combination, the number would be CX6 + C354.
All tanks include the following: suction strainer (100 mesh); breather (40 micron); oil sight level glass; motor mounting
holes drilled and tapped. Pump-motor-tank combinations include piping to the suction side of the pump.
The precision alignment of the motor to the “C” Series pump is assured by a machined adaptor bracket. The ½ to 1 ½
H.P. electric motors are frame 56C, continuous duty, ball-bearing, totally enclosed, fan cooled units of the highest quality.
The motors are offered as standard in either single phase, 115 and 230 volt, 1750 RPM or three phase, 208, 230 and 460
volt, 1750 RPM, 50/60 cycle current.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump C1 C2 C4 C6 C8
Motor .00028 GPR .00047 GPR .0081 GPR .00137 GPR .00202 GPR
C154 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
1 Phase TEFC C1+C154 C2+C154 C4+C154 C6+C154 C8+C154
C354 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
3 Phase TEFC C1+C354 C2+C354 C4+C354 C6+C354 C8+C354
C174 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
1 Phase TEFC C1+C174 C2+C174 C4+C174 C6+C174 C8+C174
C374 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
3 Phase TEFC C1+C374 C2+C374 C4+C374 C6+C374 C8+C374
C1104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
1 Phase TEFC C1+C1104 C2+C1104 C4+C1104 C6+C1104 C8+C1104
C3104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
3 Phase TEFC C1+C3104 C2+C3104 C4+C3104 C6+C3104 C8+C3104
C1154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
1 Phase TEFC C4+C1154 C6+C1154 C8+C1154
C3154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
3 Phase TEFC C4+C3154 C6+C3154 C8+C3154
Page 59
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
CT Series Power Unit with 5 Gallon Tank
CX Series Power Unit with 10 Gallon Tank
MOTOR C154 C354 C174 C374 C1104 C3104 C31154 C3154
DIMENSION 13.38 12.75 14.25 12.75 14.43 13.43 15.25 13.38
PUMP C1 C2 C4 C6 C8
DIMENSION 2.48 2.57 2.74 3.02 3.34
Note: Motor and bracket dimensions subject to change due to availability of inventory.
Performance Data
Page 60
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
BCV Series Power Packages
Vertical Pump Motor, combinations 3.5 to 10.5GPM with 3 to 20 HP, C face, TEFC motors (Pressures to 3000 PSI).
Available on 15, 20 and 30 gallon non JIC reservoirs. Each unit features a fixed displacement gear pump submerged
below oil level for assured pump filling and quiet operation. Filler breather assembly, suction strainer, sight level and
temperature gauge standard. Optional valve systems result in a complete custom hydraulic Power Unit. These units use
the PH series pumps noted in the pump section of the catalog.
Accessories/Options
• Relief valve • Single-phase motors
• Pressure gauge and shutoff • Explosion-proof motors
• Return line filter • Custom manifolds
• Directional control valves • Pressure switch
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Pump BCV312 BCV313 BCV314 BCV315 BCV318 BCV319
Motor .499 CIR .589 CIR .677 CIR .860 CIR 1.220 CIR 1.403 CIR
3304
3 H.P. 1725 RPM 1225 PSI 1000 PSI 900 PSI 700 PSI 500 PSI 425 PSI
182TC Frame 3.7 GPM 4.4 GPM 5.0 GPM 6.4 GPM 9.1 GPM 10.4 GPM
3 Phase TEFC BCV312-3304 BCV313-3304 BCV314-3304 BCV315-3304 BCV318-3304 BCV319-3304
3504
5 H.P. 1725 RPM 2050 PSI 1725 PSI 1500 PSI 1200 PSI 825 PSI 725 PSI
184TC Frame 3.7 GPM 4.4 GPM 5.0 GPM 6.4 GPM 9.1 GPM 10.4 GPM
3 Phase TEFC BCV312-3504 BCV313-3504 BCV314-3504 BCV315-3504 BCV318-3504 BCV319-3504
3754
7.5 H.P. 1725 RPM 3000 PSI 2600 PSI 2250 PSI 1725 PSI 1250 PSI 1100 PSI
213TC Frame 3.6 GPM 4.3 GPM 4.9 GPM 6.4 GPM 9.1 GPM 10.3 GPM
3 Phase TEFC BCV312-3754 BCV313-3754 BCV314-3754 BCV315-3754 BCV318-3754 BCV319-3754
31004
10 H.P. 1725 RPM 3000 PSI 3000 PSI 2325 PSI 1675 PSI 1450 PSI
215TC Frame 4.3 GPM 4.9 GPM 6.3 GPM 9.0 GPM 10.3 GPM
1 Phase TEFC BCV313-31004 BCV314-31004 BCV315-31004 BCV318-31004 BCV319-31004
31504
15 H.P. 1725 RPM 3000 PSI 2500 PSI 2200 PSI
254TC Frame 6.3 GPM 9.0 GPM 10.2 GPM
3 Phase TEFC BCV315-31504 BCV318-31504 BCV319-31504
32004
20 H.P. 1725 RPM 2850 PSI 2500 PSI
256TC Frame 9.0 GPM 10.2 GPM
3 Phase TEFC BCV318-32004 BCV319-32004
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Page 61
PUMP, MOTOR AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
BCV Series 15, 20, and 30 Gallon Tanks
Performance Data
TANK T-15V T-20V T-30V
MOTOR "A" "B" "B" "B"
3304 12.96 25.52 29.52 37.52
3504 13.96 26.52 30.52 38.52
3754 13.99 26.92 29.92 38.92
31004 16.49 29.05 33.05 41.05
31504 17.87 30.43 34.43 42.43
32004 19.63 32.19 36.19 44.19
"C" 12.56 16.56 24.56
Note: Motor and Flange dimensions are
a
pp
roximate de
p
endent on current availabilit
y
Page 62
PUMP, MOTOR, VALVE AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
BV Series
INDEX
Description Page
BV Series Units
65
Page 63
Page 64
PUMP, MOTOR, VALVE AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
BV Series Power Packages
BV Series with Valve and 1 Gallon Tank BV Series with Valve and 10 Gallon Tank
Delta BV models provide increased flexibility by incorporating a standard 4way 3position valve directly to the power unit.
In all, over 100 standard model and combinations to choose from.
Satisfy many custom circuit requirements through use of standard Delta valves, manifolds and stack modules illustrated.
Pump / Motor Specifications
Data shown is for continuous duty. For intermittent peaking duty, 30 seconds at peak load, pressure as high as 150% is
attainable, limited to 3000 PSI maximum.
Note: 3 phase motors can run on 50/60 cycles but flow at 50 cycles will be reduced to 5/6 of noted flow since the motor
will run at 5/6 of the RPM.
Pump BV1 BV2 BV4 BV6 BV8
Moto
r
.00028 GPR .00047 GPR .0081 GPR .00137 GPR .00202 GPR
B154 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
1 Phase TEFC BV1+B154 BV2+B154 BV4+B154 BV6+B154 BV8+B154
B354 .31 GPM .70 GPM 1.33 GPM 2.32 GPM 3.46 GPM
1/2 H.P. 1725 RPM 1500 PSI 900 PSI 525 PSI 300 PSI 200 PSI
3 Phase TEFC BV1+B354 BV2+B354 BV4+B354 BV6+B354 BV8+B354
B174 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
1 Phase TEFC BV1+B174 BV2+B174 BV4+B174 BV6+B174 BV8+B174
B374 .25 GPM .65 GPM 1.28 GPM 2.28 GPM 3.44 GPM
3/4 H.P. 1725 RPM 2250 PSI 1350 PSI 775 PSI 450 PSI 300 PSI
3 Phase TEFC BV1+A374 BV2+B374 BV4+B374 BV6+B374 BV8+B374
B1104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
1 Phase TEFC BV1+B1104 BV2+B1104 BV4+B1104 BV6+B1104 BV8+B1104
B3104 .25 GPM .58 GPM 1.25 GPM 2.25 GPM 3.40 GPM
1 H.P. 1725 RPM 2250 PSI 1800 PSI 1050 PSI 625 PSI 425 PSI
3 Phase TEFC BV1+B3104 BV2+B3104 BV4+B3104 BV6+B3104 BV8+B3104
B1154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
1 Phase TEFC BV4+B1154 BV6+B1154 BV8+B1154
B3154 1.17 GPM 2.18 GPM 3.34 GPM
1-1/2 H.P. 1725 RPM 1550 PSI 925 PSI 625 PSI
3 Phase TEFC BV4+B3154 BV6+B3154 BV8+B3154
B3204 2.06 GPM 3.26 GPM
2 H.P. 1725 RPM 1225 PSI 850 PSI
3 Phase TEFC BV6+B3204 BV8+B3204
B3304 1.90 GPM 3.12 GPM
3 H.P. 1725 RPM 1850 PSI 1250 PSI
3 Phase TEFC BV6+B3304 BV8+B3304
Intermittent Dut
y
Caution: Relief valves must be set prior to installation. They are not factory
preset. Relief valves will include springs which will allow relief valves settings to
the pressures indicated on the chart.
BV6+B174 Pump/Motor/Valve/1 Gal. Tank
To order Power unit with 1-1/2 gallon tank, specify as follows
BV6+B174-1-1/2 TK Pump/Motor/Valve/1-1/2 Gal. Tank
To order Power unit with 2-1/2 gallon tank, specify as follows
BV6+B174-2-1/2 TK Pump/Motor/Valve/2-1/2 Gal. Tank
To order Power unit with 5 gallon tank, (add letter T), as follows
BVT6+B174 Pump/Motor/Valve/5 Gal. Tank
To order Power unit with 5 gallon tank, (add letter X), as follows
BVX6+B174 Pump/Motor/Valve/10 Gal. Tank
Pump No. Slip GPM / 100 PSI
GPM @ 0.PSI
1725 RPM
B1 0.015 0.48
B2 0.017 0.81
B4 0.020 1.40
B6 0.025 2.36
B8 0.030 3.49
Page 65
PUMP, MOTOR, VALVE AND TANK COMBINATIONS Delta Power Company
4484 Boeing Drive - Rockford, IL 61109
WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described
(herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.
Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: delta@delta-power.com
BV Series Power Unit with 1 Gallon Tank
BVT Series with Valve and 5 Gallon Tank BVX Series with Valve and 10 Gallon Tank
Directional Control Valves and Stack Modules Accessory Options
Stack Modules
Performance Data
Motor
A
BCDE
B154 11.13 19.69 19.38 9.75 9.88
B354 10.50 19.06 18.75 9.13 9.25
B174 10.50 19.06 18.75 9.13 9.25
B374 10.50 19.06 18.75 9.13 9.25
B1104 12.13 20.69 20.38 10.75 10.88
B3104 11.00 19.56 19.25 9.63 9.75
B1154 12.50 21.06 20.75 11.13 11.25
B3154 11.00 19.56 19.25 9.63 9.75
B3204 12.13 20.69 20.38 10.75 10.88
B3304 12.88 21.44 21.13 11.50 11.63
110 VAC 220 VAC
4W3P Tandem Center 22020116 22020117
4W3P Open Center 22020118 22020119
4W3P Closed Center 22020120 22020121
4W3P Figure Four 22020122 22020123
Part Number
DESCRIPTIONSYMBOL
SYMBOL DESCRIPTION Part No. Bolt Kit No.
Flow Control
Meter In/Out
3000 PSI
85004206 BK-7
Dual Pilot Operated
Check
(
4:1 Ratio
)
3000 PSI
85004025 BK-7
2 1/2" Dia. Std. 21001003
2 1/2" Dia.Glyc. 21001007
21002001
21004001
Pressure gauge & shut off including
installation with B or BV power units
Return line filter including installation (10 micron)
nominal; 20 GPM maximum
Pressure switch including installation