How to design masonry structures using Eurocode 6 2. Vertical resistance Eur Ing, Prof. Revision 2 J J Roberts BSc(Eng), PhD, CEng, FIStructE, FICE, FIMS, FCMI, MICT O Brooker BEng, CEng, MICE, MIStructE Introduction This publication is part of a series of three guides entitled How to design masonry structures using Eurocode 6. The aim is to make the use of Eurocode 6, Design of masonry structures as easy as possible by drawing together in one place key information and commentary required for the design of typical masonry elements. The Concrete Centre (and, originally, The Modern Masonry Alliance) recognised that effective guidance was required to ensure that the UK design profession was able to use Eurocode 6 quickly, effectively, efficiently and with confidence. Therefore a steering group, with members from across the masonry industry (see back cover for a list of members), was established to oversee the development and publication of the original guides. This second revision addresses the publication of PD6697 in 2010 and revised National Annex to BS EN 1996-1-1 in 2013. It was overseen by a reconstituted steering group from industry (see back cover). Guidance for vertical resistance This guide is the second in a series of three giving guidance on the design of masonry structures to Eurocode 61. The first guide, Introduction to Eurocode 62 gives an introduction to design and assessment of actions using Eurocode 6 and also covers the specification and execution (workmanship) of masonry. This guide explains how to design for vertical actions and determine vertical resistance. The third guide in the series3 covers the design of laterally loaded masonry panels. Throughout this guide the Nationally Determined Parameters (NDPs) from the UK National Annexes (NAs) have been used. These enable Eurocode 6 to be applied in the UK. Design procedure This guide explains how to determine the design resistance for a vertically loaded wall. The first guide in the series, Introduction to Eurocode 6, should be referred to so that the design load can be determined. In essence, when using the Eurocodes the designer should check that the resistance is greater than or equal to the effect of the actions. A flow chart for the design of masonry walls to resist vertical actions is shown as Figure 1. Compressive strength Eurocode 6 introduces some new concepts when dealing with the design of masonry for vertical loads. The first of these relates to the way the compressive strength of the masonry units is expressed. For design purposes the normalized compressive strength, fb, of the masonry units is used. This is the compressive strength of the units converted to the air-dried compressive strength of an equivalent 100 mm wide by 100 mm high masonry unit. The detail is contained in Part 1 of BS EN 772, Methods of test for masonry units4. The advantage to the designer is that the normalized strength is independent of the size and shape of the units used in the final construction. Grouping of masonry units The second change relates to the way in which masonry units are classified. This is dealt with by grouping masonry into one of four groups as shown in Table 3.1 of Eurocode 6. The group designation will normally be declared by the manufacturer. The designation depends upon the volume and direction of holes in the unit and the thickness of webs and shells. Historically only Group 1 and Group 2 units have been used in the UK, so only values for these groups are given in the UK NAs. How to design masonry masonrystructures structuresusing usingEurocode Eurocode66 The characteristic compressive strength of masonry The characteristic compressive strength of masonry (other than shell bedded masonry) is determined from the results of tests in accordance with BS EN 1052–15. The tests are carried out on small wallette specimens rather than the storey-height panels used in the past. The designer has the option of either testing the units intended to be used in a project or using the values determined from a database. Values from a large database are provided in the UK NA to Eurocode 6, Part 1–1 in the form of the constants to be used in the following equation: fk = K fba fmb [Equation (3.1) of Eurocode 6, Part 1–1] where fk = characteristic compressive strength of the masonry, in N/mm2 K = constant – see Table 1 and Figure 2 a, b = constants – see Table 2 fb = normalized mean compressive strength of the units, in the direction of the applied action effect, in N/mm2 fm = compressive strength of the mortar, in N/mm2 For blocks laid flat, Table 8 of the National Annex to Eurocode 6, Part 1–1 contains a specific value for K to be used in Equation (3.1) of Eurocode 6, Part 1–1. The following limitations are placed on Equation (3.1): ¢¢ The masonry is detailed and constructed in accordance with the requirements of BS EN 1996–1–1, section 8. ¢¢ fb is taken to be not greater than 110 N/mm2 when units are laid in general purpose mortar and 50 N/mm2 when laid in thin layer mortar (fb is determined in the normal direction of loading). ¢¢ fm is taken to be not greater than fb nor greater than 12 N/mm2 when units are laid in general purpose mortar or 10 N/mm2 when units are laid in lightweight mortar. ¢¢ The coefficient of variation of the strength of the masonry unit is not more than 25%. For masonry made with general purpose mortar, adjustments are made to the value of K as shown in Figure 2. In addition the following points should be noted: ¢¢ For masonry made of general purpose mortar where Group 2 and Group 3 aggregate concrete units are used with the vertical cavities filled completely with concrete, the value of fb should be obtained by considering the units to be Group 1 having a compressive strength corresponding to the compressive strength of the units or of the concrete infill, whichever is the lesser. Figure 1 Flow chart for the design of masonry walls to resist vertical actions Characteristic vertical actions Masonry unit properties • Type and group • Dimensions • Strength Determine requirements for mortar strength and durability. See tables 5 & 6 of Introduction to Eurocode 6 Determine normalized compressive strength, fb. Determine characteristic compressive strength of masonry, fk, from Equation (3.1) of Eurocode 6 and Tables 1 & 2 Determine effective height, hef, of the wall (see page 4) . Determine effective thickness, tef, of the wall (see page 4) Check area ≥ 0.04 m2 Check slenderness ratio hef /tef ≤ 27 Determine design value of vertical actions (per unit length), Ed, using Expression (6.10), (6.10a) or (6.10b) of Eurocode (see Introduction to Eurocode 6) Where cross-sectional area, A < 0.1 m2, factor fk by (0.7 + 3A) Calculate design resistance (per unit length) from least favourable of: NRd = Fm t fk / gM and NRd = Fi t fk / gM Check Ed ≤ NRd Determine eccentricity (see page 5) Determine capacity reduction factors, Fm and Fi from (see page 6) 2 Obtain gM from table 1 of Introduction to Eurocode 6 Check complete 2. Vertical resistance ¢¢ For collar jointed aggregate concrete masonry made with general purpose mortar, with or without the collar filled with mortar, the unit shape factor correction to obtain the normalized strength should use the width of the wall as the unit width and the height of the masonry units. ¢¢ Where action effects are parallel to the direction of the bed joints, the characteristic compressive strength may be determined from Equation (3.1) with fb derived from BS EN 772–1, where the direction of application of the load to the test specimens is in the same direction as the direction of the action effect in the masonry, but with the shape factor, d, as given in BS EN 772–1 taken to be no greater than 1.0. For Group 2 and 3 units, K should then be multiplied by 0.5. Table 1 Values of K to be used with equation (3.1) Masonry unit General purpose mortar Thin layer mortar (bed joint ≥ 0.5 mm and ≤ 3 mm) Lightweight mortar of density (kg/m3) 800 < rd 600 ≤ rd ≤ 800 ≤ 1300 Clay Group 1 0.50 0.75 0.30 0.40 Group 2 0.40 0.70 0.25 0.30 –a –a –a Group 3 and 4 – a Calcium silicate Group 1 0.50 0.80 –b –b Group 2 0.70 –b –b 0.90 0.45 0.45 Group 1 c 0.50 d (units laid flat) Group 2 0.70 0.70d 0.40d 0.40d 0.76 0.45 0.45 Group 3 and 4 – a –a –a –a Autoclaved aerated concrete Group 1 0.75 0.90 0.45 0.45 Manufactured stone Group 1 0.75 –b –b –b –b 0.40 Aggregate concrete Group 1 0.75 0.90 Dimensioned natural stone Group 1 0.45 –b ¢¢ When the perpendicular joints are unfilled, Equation (3.1) may be used, with consideration of any horizontal actions that might be applied to, or be transmitted by, the masonry. (See also CI. 3.6.2(4) of BS EN 1996–1–1.) The characteristic compressive strength of shell bedded masonry Shell bedding provides two strips of mortar rather than a full mortar bed. It serves to improve rain penetration resistance but reduces the strength of the masonry. A typical shell bedded unit is shown in Figure 3. For Group 1 and Group 4 units the procedure above may be used to obtain the characteristic compressive strength of the masonry. Figure 2 Modifications to K for units laid with general purpose mortar Plan sections of bonded masonry Masonry thickness a) K from Table 1 Masonry thickness b) K from Table 1 Masonry thickness Key a Group 3 and 4 units have not traditionally been used in the UK, so no values are available. b T hese masonry unit and mortar combinations have not traditionally been used in the UK, so no values are available. c) K from Table 1 multiplied by 0.8 c If Group 1 aggregate concrete units contain formed vertical voids in the normal direction, multiply K by (100 – n) /100, where n is the percentage of voids, maximum 25%. Masonry thickness d W hen aggregate concrete masonry units are to be used laid flat the normalised strength of the unit should be calculated using the width and height of the unit in the upright position along with the compressive strength of the unit tested in the upright position. Note Where a mortar joint is parallel to the face of the wall K should be modified (see Figure 2) Figure 3 Table 2 Shell bedding Values to be used in Equation (3.1) Type of mortar General purpose mortar Lightweight mortar Thin layer mortar in bed joints of thickness 0.5 to 3 mm (using clay units of Group 1, calcium silicate units, aggregate concrete units and autoclaved aerated concrete units) Thin layer mortar in bed joints of thickness 0.5 to 3 mm (using clay units of Group 2) d) K from Table 1 multiplied by 0.8 Values to be used a = 0.7 and b = 0.3 a = 0.7 and b = 0.3 a = 0.85 and b = 0 a = 0.7and b = 0 3 How to design masonry masonrystructures structuresusing usingEurocode Eurocode66 provided that: ¢¢ The width of each strip of mortar is at least 30 mm. ¢¢ The thickness of the masonry wall is equal to the width or length of the masonry units so that there is no longitudinal mortar joint through all or part of the length of the wall. ¢¢ The ratio g/t is not less than 0.4 where g = total width of the mortar strips t = the thickness of the wall. ¢¢ K is taken as above when g/t = 1.0 or half this value when g/t = 0.4. Linear interpolation may be used for intermediate values. Groups 2 and 3 may be designed as non-shell bedded masonry provided that the normalized mean compressive strength of the units used in Equation (3.1) is obtained from tests carried out in accordance with BS EN 772–14 for shell bedded units. Effective height The effective height of a masonry wall is obtained by applying a factor to the clear height of the wall such that: hef = rn h where hef = effective height of the wall h = clear storey height of the wall rn = reduction factor, where n = 2, 3 or 4, depending upon the edge restraint or stiffening of the wall The reduction factor to be applied depends upon the restraint offered by adjoining elements. Masonry walls may be stiffened by a number of rigid structural elements such as floors, roofs and other walls. Stiffening walls should have a length of at least 1/5 of the clear height and have a thickness of at least 0.3 times the effective thickness of the wall to be stiffened. When the stiffening wall contains openings, the minimum length of wall should be as shown in Figure 4 and the stiffening wall should extend a distance of at least 1/5 of the storey height beyond each opening. Where a wall is restrained at the top and bottom by reinforced concrete floors or roofs spanning from both sides at the same level or by a reinforced concrete floor spanning from one side only and having a bearing of at least 2/3 of the thickness of the wall then: r2 = 0.75 unless the eccentricity of the load at the top of the wall is greater than 0.25 times the thickness of the wall, in which case r2 = 1.0. Where the wall is restrained by timber floors or roofs spanning from both sides at the same level or by a timber floor spanning from one side having a bearing of at least 2/3 the thickness of the wall but not less than 85 mm, then: r2 = 1.0. For walls restrained at the top and bottom and stiffened on one vertical edge, use rn = the value r3 from Figure 5 and where both vertical edges are stiffened, use rn = the value r4 from Figure 6. Note that Equations (5.6), (5.7) and (5.8) in Eurocode 6, Part 1–1 may be used as an alternative to the use of the graphs. Effective thickness For a single-leaf wall, a double-leaf wall (with ties at a density of 2.5 per m2 or greater), a faced wall, a shell bedded wall and a grouted cavity wall, the effective thickness, tef, is taken as the actual thickness Figure 4 Figure 5 Minimum length of stiffening wall with openings Graph showing values of r3 1.0 Stiffened wall Stiffening wall r2 = 1.0 0.9 t h >h/5 h1 h2 (window) h2(door) Reduction factor, r3 0.8 0.7 r2 = 0.75 0.6 0.5 0.4 0.3 0.2 0 1 (h1+ h2) 5 4 2 >t 1 2 3 Ratio hef /tef 4 5 2. Vertical resistance of the wall (t), provided this is greater than the minimum thickness, tmin. The value of tmin for a loadbearing wall should be taken as 90 mm for a single-leaf wall and 75 mm for the leaves of a cavity wall. For a cavity wall the effective thickness is determined using the following equation: tef = 3R t13 + t23 ≥ t2 Assessment of eccentricity When a wall is subjected to actions that result in an eccentricity at right angles to the wall, Eurocode 6 requires the resistance of the wall to be checked at the top, mid-height and bottom. The eccentricity at top or bottom of the wall is: Mid ei = where t1 = actual thickness of the outer or unloaded leaf t2 = actual thickness of the inner or loaded leaf Note that the effective thickness of the unloaded leaf should not be taken to be greater than the thickness of the loaded leaf and that ties should be provided at a density of 2.5 per m2 or greater. When a wall is stiffened by piers the effective thickness is enhanced by using the following equation: tef = rtt where tef = effective thickness rt = coefficient obtained from Table 3 t = thickness of the wall Nid + ehe + einit ≥ 0.05t where Mid = design value of the bending moment at the top or the bottom of the wall resulting from eccentricity of the floor load at the support Nid = design value of the vertical load at the top or the bottom of the wall ehe = the eccentricity at the top or bottom of the wall resulting from the horizontal loads einit = initial eccentricity for construction imperfections, which may be taken as hef/450, with a sign that increases the absolute value of ei and em as appropriate t = thickness of the wall The mid-height eccentricity, emk, is: emk = em + ek ≥ 0.05t Slenderness ratio where The slenderness ratio of the wall is obtained by dividing the effective height by the effective thickness and should not be greater than 27 for walls subjected to mainly vertical loading. Note also that the effects of creep may be ignored in walls with a slenderness ratio up to 27. Figure 6 Graph showing values of the reduction factor, r4 1.0 r2 = 1.0 0.9 = ek = 0, when the slenderness ratio ≤ 27 (ie. ignoring creep) Nmd + ehm + einit Mmd = design value of the greatest moment at the mid-height of the wall resulting from the moments at the top and bottom of the wall, including any load applied eccentrically to the face of the wall (see Figure 7) Nmd = design value of the vertical load at the mid-height of the wall, including any load applied eccentrically to the face of the wall ehm = the eccentricity at mid-height resulting from horizontal loads A sub-frame analysis may be used as a simplified method for obtaining the moments at the top and bottom of vertically loaded walls, as given in Annex C in Part 1–1 of Eurocode 6. 0.8 Reduction factor, r4 Mmd em 0.7 0.6 Table 3 r2 = 0.75 Stiffness coefficient, rt, for walls stiffened by piers 0.5 Ratio of pier spacing (centre to centre) to pier width 0.4 0.3 0.2 0 1 2 3 Ratio h/l 4 5 Ratio of pier thickness to actual thickness of wall to which it is bonded 1 2 3 6 1.0 1.4 2.0 10 1.0 1.2 1.4 20 1.0 1.0 1.0 Note Linear interpolation is permitted in this Table. 5 How to design masonry masonrystructures structuresusing usingEurocode Eurocode66 Capacity reduction factors At the top or bottom of the wall, the reduction factor for slenderness and eccentricity is given by: e Fi = 1 – 2 i t where Fi = reduction factor at the top or bottom of the wall ei = eccentricity at the top or bottom of the wall t = thickness of the wall A method for calculating a capacity reduction factor at the mid-height of the wall, Fm, is given in Annex G of Eurocode 6, Part 1–1, which simplifies the principles given in Cl. 6.1.1. This is shown graphically in Figure 8, which shows the corresponding capacity reduction factors for different values of slenderness and eccentricity for an elastic modulus 1000 fk , which is the value recommended in the UK NA. The least favourable value of Fi and Fm should be used to calculate NRd. Vertical load resistance of solid walls and columns The design resistance of a single-leaf wall per unit length, NRd, is given by the following: t = thickness of the wall fd = design compressive strength of the masonry ( fk /gM) For sections of small plan area, less than 0.1 m2, fd should be multiplied by (0.7 + 3A) where A = loadbearing horizontal cross-sectional area of the wall in m2 In the case of a faced wall, the wall may be designed as a single-leaf wall constructed entirely of the weaker material with a longitudinal joint between leaves. A double-leaf (collar-jointed) wall may also be designed as for a single-leaf wall provided that the leaves are tied together adequately and both leaves carry similar loads and the cavity does not exceed 25 mm, or it may be designed as a cavity wall with one leaf loaded. In the case of cavity walls, check each leaf separately using a slenderness ratio based on the effective thickness of the wall. Concentrated loads For a Group 1 unit (not shell bedded) the vertical load resistance is: NRdc = b Ab fd where b = 1 + 0.3 1.5 – 1.1 Ab hc Aef = e nhancement factor for load that should not be less than 1.0 nor taken to be greater than: a 1.25 + 1 or 1.5, whichever is the lesser 2hc NRd = F tfd where F = capacity reduction factor allowing for the effects of slenderness and eccentricity of loading a1 Figure 8 Capacity reduction factor, Fm at the mid-height of the wall Figure 7 Moments from calculation of eccentricities Eccentricity = 1.0 0.05t 0.9 N1d h2 Nmd Mmd (at mid-height of wall) h h2 N2d M2d (at top of floor) 0.10t 0.8 Capacity reduction factor, Fm M1d (at underside of floor) 0.15t 0.7 0.20t 0.6 0.25t 0.5 0.30t 0.4 0.35t 0.3 0.40t 0.2 0.1 0.0 0 a) Section 6 b) Bending moment diagram 5 10 15 20 Ratio, hef /ltef 25 Values of Fm at the mid-height of the wall against slenderness ratio for different eccentricities, based on E =1000 fk 30 2. Vertical resistance a1 = distance from the end of the wall to the nearer edge of the loaded area hc = height of the wall to the level of the load Ab = loaded area Aef = effective area of the bearing, lefm t lefm = effective length of the bearing as determined at the mid-height of the wall or pier t = thickness of the wall, taking into account the depth of recesses in joints greater than 5 mm wide Ab/Aef ≤ 0.45 The enhancement factor, b, is shown graphically in Figure 9. For walls built with Groups 2, 3 and 4 masonry units and when shell bedding is used, it is necessary to check that, locally under the bearing of a concentrated load, the design compressive stress does not exceed the design compressive strength of the masonry, fd (i.e. b is taken to be 1.0). In any case, the eccentricity of the load from the centre line of the wall should not be greater than t/4 as shown in Figure 10. In all cases where a concentrated load is applied, the requirements for vertical load design should be met at the mid-height of the wall below the bearings. Account should be taken of the effects of any other superimposed vertical loading, particularly where concentrated loads are sufficiently close together for their effective lengths to overlap. The concentrated load needs to bear on a Group 1 unit or other solid material. The length of this unit or bearing should equal the required bearing length plus a length on each side of the bearing based on a 60° spread of load to the base of the solid material. For an end bearing the extra length is required on one side only. The concentrated load may be applied through a spreader beam of adequate strength and stiffness that has a width the same as the wall thickness, a height greater than 200 mm and a length greater than three times the bearing length of the load. In this case the design value of compressive strength beneath the concentrated load should not exceed 1.5fd. Walls subject to shear forces The design value of shear resistance is given by: VRd = f vd tl c where VRd = the design value of shear resistance of the wall fvd = the design value of the shear strength of the masonry (the characteristic shear strength divided by the partial factor for masonry, gM) based on the average vertical stresses over the compressed part of the wall that is providing the shear resistance t = the thickness of the wall resisting the shear lc = the length of the compressed part of the wall, ignoring any part of the wall that is in tension In calculating lc assume a linear distribution of the compressive stress, take into account openings, etc. and do not include any area of the wall subjected to vertical tensile stresses. Effect of chases Eurocode 6 recognises that chases and recesses should not impair the stability of a wall and provides appropriate guidance. Further explanation is given in the third guide in this series, Lateral resistance3. Figure 9 Figure 10 Enhancement factor, b, concentrated load under bearings Walls subjected to concentrated load NEdc NEdc NEdc 1.6 a1 60o Enhancement factor, b 1.5 60o 60o hc/2 h 1.4 + 2a1 = 1 hc 1.3 + lefm lefm + + lefm a1 = 0 a) Elevation 1.2 NEdc a 1 1.1 NEdc Ab 60o hc 1.0 0 0.1 0.2 0.3 0.4 0.45 0.5 ≤ t /4 t lefm t Ratio, Ab / Aef b) Section c) Plan d) Section 7 2. Vertical resistance Selected symbols Symbol Definition Symbol Definition A Loadbearing horizontal cross-sectional area of the wall in m2 lefm Effective length of the bearing as determined at the mid-height of the wall or pier Mid Design value of the bending moment at the top or the bottom of the wall resulting from eccentricity of the floor load at the support Mmd Design value of the greatest moment at the mid-height of the wall resulting from the moments at the top and bottom of the wall, including any load applied eccentrically to the face of the wall a1 Distance from the end of the wall to the nearer edge of the loaded area Ab Loaded area Aef Effective area of the bearing ehe Eccentricity of the top or bottom of the wall resulting from horizontal loads ehm Eccentricity at the middle of a wall, resulting from horizontal loads Nid Design value of the vertical load at the top or the bottom of the wall ei Eccentricity of the wall Nmd einit Initial eccentricity Design value of the vertical load at the mid-height of the wall, including any load applied eccentrically to the face of the wall. em Load eccentricity NRd Design resistance of a single-leaf wall per unit length emk Eccentricity at the mid-height of the wall NRdc Design vertical load resistance to a concentrated load fb Normalized mean compressive strength of a masonry unit fd Design compressive strength of the masonry in the direction being considered t2 Effective thickness of the of the inner or loaded leaf fm Compressive strength of the mortar tef Effective thickness fk Characteristic compressive strength of the masonry, in N/mm2 tmin Minimum thickness of loadbearing wall fvk Characteristic shear strength of masonry VRd Design value of shear resistance of the wall fvd Design value of the shear strength of the masonry v Notional inclination angle to the vertical g Total of the widths of the mortar strips a and b Constants to be used with Equation (3.1) of Eurocode 6, Part 1–1 h Clear storey height of the wall b An enhancement factor for concentrated load hc Height of the wall to the level of the load F hef Effective height of the wall Capacity reduction factor allowing for the effects of slenderness and eccentricity of loading htot Total height of the structure K lc t Thickness of the wall t1 Effective thickness of the outer or unloaded leaf gM Partial factor for a material property Constant to be used with Equation (3.1) of Eurocode 6, Part 1–1 rn Reduction factor (depending upon the edge restraint or stiffening of the wall, h/l and floor restraint) Length of the compressed part of the wall, ignoring any part of the wall that is in tension. rt Stiffness coefficient References 1 BRITISH STANDARDS INSTITUTION. BS EN 1996: Eurocode 6 – Design of masonry structures. BSI (4 parts). Including their NAs. 2 ROBERTS, JJ & Brooker, O. How to design masonry structures to Eurocode 6: Introduction to Eurocode 6. The Concrete Centre, 2013. 3 ROBERTS, JJ & Brooker, O. How to design masonry structures to Eurocode 6: Lateral resistance. The Concrete Centre. 2013. 4 BRITISH STANDARDS INSTITUTION. BS EN 772–1: Methods of test for masonry units – Determination of compressive strength. BSI, 2011. 5 BRITISH STANDARDS INSTITUTION. BS EN 1052–1: Methods of test for masonry – Determination of compressive strength. BSI, 1999. Members of the steering group Acknowledgements Ali Arasteh, Brick Development Association; Owen Brooker, The Concrete Centre; Ken Fisher, International Masonry Society; Cliff Fudge, Aircrete Products Association; Charles Goodchild, The Concrete Centre; Gerry Pettit, Concrete Block Association; John Roberts, Consultant. This publication was jointly sponsored by the following organisations: Members of the steering group for 2nd revision ¢¢ Concrete Block Association - www.cba-blocks.org.uk Cliff Fudge, Aircrete Products Association; Charles Goodchild, The Concrete Centre; Simon Hay, Brick Development Association; Andy Littler, Concrete Block Association; John Roberts, Consultant; Guy Thompson, The Concrete Centre. ¢¢ MPA - Mortar Industry Association - www.mortar.org.uk For more information on Eurocode 6 and other questions relating to the design, use and performance of concrete units, visit www.eurocode6.org Ref: TCC/03/36. ISBN 978-1-904818-57-1 First published December 2007 (in partnership with the Modern Masonry Alliance) revised January 2009 and June 2013 8 Price Group M © MPA The Concrete Centre™ ¢¢ Aircrete Products Association - www.aircrete.co.uk ¢¢ Brick Development Association - www.brick.org.uk ¢¢ MPA - The Concrete Centre - www.concretecentre.com Published by The Concrete Centre Gillingham House, 38-44 Gillingham Street, London, SW1V 1HU Tel: +44 (0)207 963 8000 | www.concretecentre.com All advice or information from MPA The Concrete Centre (TCC) et al is intended only for use in the UK by those who will evaluate the significance and limitations of its contents and take responsibility for its use and application. No liability (including that for negligence) for any loss resulting from such advice or information is accepted by TCC or their subcontractors, suppliers or advisors. Readers should note that the publications from TCC et al are subject to revision from time to time and should therefore ensure that they are in possession of the latest version.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:1f420dc7-adbc-644b-bc72-fef1b5a7fbca Original Document ID : adobe:docid:indd:110982ba-58a4-11dc-9e1c-a43be38fab1a Document ID : xmp.id:CD7D7DE5152068118A6DD5388AF78715 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:CC7D7DE5152068118A6DD5388AF78715 Derived From Document ID : adobe:docid:indd:110982ba-58a4-11dc-9e1c-a43be38fab1a Derived From Original Document ID: adobe:docid:indd:110982ba-58a4-11dc-9e1c-a43be38fab1a Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:12:19 10:55:38Z Create Date : 2013:12:19 10:55:38Z Modify Date : 2013:12:19 10:55:56Z Metadata Date : 2013:12:19 10:55:56Z Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Layout : TwoPageRight Page Mode : UseThumbs Page Count : 8 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools