Design Span HP Product Guide Load Tables

Design_Span_HP_Product_Guide_Load_Tables

User Manual:

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadDesign Span HP Product Guide Load Tables
Open PDF In BrowserView PDF
Design Span® hp
Design Span hp is a performance-rated structural standing
seam, concealed fastener metal
roof system with net coverage of
12", 16", 17" & 18".
Design Span hp is excellent as a
roof over metal or wood decking, and
as a fascia or mansard over plywood
or supports.

"
"
Optional Batten
offers a clean
bold look.

Available with subtle striations for a clean pan (16", 17" & 18")

13⁄4″
12", 16", & 17" Net Coverage
(18" available – additional charges and lead times apply)

Section Properties
Width

12"
16"
17"
18"

Gauge

Base Steel
Thickness (in)

Yield
(ksi)

Tensile
(ksi)

Wt.
(lbs/ft2)

I+
(in4/ft)

S+
(in3/ft)

I(in3/ft)

S(in3/ft)

24

0.0232

50

65

1.45

0.1185

0.0820

0.0762

0.0586

22

0.0294

50

65

1.83

0.1522

0.1080

0.0997

0.0771

24

0.0232

50

65

1.34

0.0943

0.0624

0.0593

0.0440

22

0.0294

50

65

1.68

0.1213

0.0825

0.0773

0.0580

24

0.0232

50

65

1.31

0.0901

0.0589

0.0562

0.0414

22

0.0294

50

65

1.65

0.1158

0.0779

0.0734

0.0546

24

0.0232

50

65

1.30

0.0858

0.0557

0.0533

0.0391

22

0.0294

50

65

1.63

0.1104

0.0737

0.0696

0.0515

NOTE: The hybrid positive moment of inertia, I, presented for determining deflection is: (2IEffective + IGross)/3

standard features
n

Factory applied sealant is a standard offer.

n

Custom manufactured sheet lengths from 6'-0" to 45'-0".

n

Subtle striations between ribs on 16" and wider panels.

n

Offered in 12", 16" & 17" widths.

n

Available in 24ga and 22ga in standard finishes Refer to AEP Span Color Charts for full range of color
options, prints, textures, finishes and paint systems.

n

Recommended minimum slope of 2:12. Inquire for
slopes below 2:12.

n

Tested in accordance with UL580-Class 90 & ASTM
E1592.

n

Has been tested for air infiltration per ASTM E1680,
and water infiltration per ASTM E1646.

n

Snap-together panel means no field seaming is required.

n

Panel evaluated by accredited third party.
All structural performance data is contained
within an IBC/IRC 2015 code compliance report.

Customer Service Centers
Tacoma, WA & Fontana, CA

Phone: 800-733-4955

optional features
n

Short cut sheets from 6'-0" to 1'-0". Additional fees
and lead times may apply.

n

Longer lengths available from 70'-0" (Tacoma, WA
facility) to 100'-0" (Fontana, CA facility). Additional
fees and lead times may apply.

n

Additional Batten option offers a clean bold look with
the structural capacity and weather resistance of
regular Design Span hp.

n

Factory notching available for turn under at the eave.

n

18" width available. Additional fees and lead times
may apply.

Fax: 253-272-0791

For most current versions of literature please visit

www.aepspan.com

Design Span® hp
12" Design Span hp

16" Design Span hp

Allowable Inward Loads (lbs/ft ) per Span (ft.-in.)

Allowable Inward Loads (lbs/ft2) per Span (ft.-in.)

2

Gauge

24

Span

2'-6"

3'-0"

3'-6"

4'-0"

4'-6"

5'-0"

Single
Span

W/Ω

409

262

182

134

102

81

65

L/180

-

-

-

-

-

-

-

Double
Span

W/Ω

285

184

128

94

72

57

46

L/180

-

-

-

-

-

-

-

W/Ω

353

228

160

118

90

71

58

Triple
Span
Single
Span
22

Cond. 2'-0"

Double
Span
Triple
Span

L/180

-

-

-

-

-

-

-

W/Ω

539

345

240

176

135

106

86

L/180

-

-

-

-

-

-

-

W/Ω

377

243

169

124

96

76

61

L/180

-

-

-

-

-

-

-

W/Ω

468

302

211

155

119

94

76

L/180

-

-

-

-

-

-

-

Gauge

24

Span

Cond. 2'-0"

2'-6"

3'-0"

3'-6"

4'-0"

4'-6"

5'-0"

Single
Span

W/Ω

309

199

138

102

78

62

50

L/180

-

-

-

-

-

-

-

Double
Span

W/Ω

214

138

96

71

54

43

34

L/180

-

-

-

-

-

-

-

W/Ω

265

171

119

88

67

53

43

Triple
Span
Single
Span
22

Double
Span
Triple
Span

L/180

-

-

-

-

-

-

-

W/Ω

412

263

183

134

103

81

66

L/180

-

-

-

-

-

-

-

W/Ω

245

183

127

93

72

57

45

L/180

-

-

-

-

-

-

-

W/Ω

278

223

158

117

90

70

57

L/180

-

-

-

-

-

-

-

Allowable Outward Loads (lbs/ft2) per Span (ft.-in.)

Allowable Outward Loads (lbs/ft2) per Span (ft.-in.)

Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0"

Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0"

24

82

76

71

67

63

59

56

52

48

24

49

42

36

30

29

29

29

28

28

22

82

76

71

67

63

59

56

52

48

22

74

66

58

49

49

48

47

47

46

LOADING TABLE LEGEND
W/Ω - Allowable panel strength
L - Span (Inches)
L/180 - Load limited by a deflection of 1/180 of the span
W - Distributed load

17" and 18" Design Span hp
Allowable Inward Loads (lbs/ft2) per Span (ft.-in.)
Gauge

24

22

Span

Cond. 2'-0"

Single
Span

f
L/180

Double
Span

2'-6"

3'-0"

3'-6"

4'-0"

4'-6"

5'-0"

275

178

124

91

70

55

44

-

-

-

-

-

-

-

f

190

123

86

62

48

38

31

L/180

-

-

-

-

-

-

-

Triple
Span

f

236

152

107

78

60

47

38

L/180

-

-

-

-

-

-

-

Single
Span

f

368

235

164

120

92

73

59

L/180

-

-

-

-

-

-

-

Double
Span

f

218

163

113

83

64

50

40

L/180

-

-

-

-

-

-

-

f

247

198

141

103

79

63

51

L/180

-

-

-

-

-

-

-

Triple
Span

Allowable Outward Loads (lbs/ft ) per Span (ft.-in.)
2

Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0"
24

48

42

35

29

29

28

28

28

27

22

67

59

51

43

43

42

42

41

41

Single span

Inward
Loads

Double span

Triple span

Outward
Loads
NOTES:
n The information in these tables applies to uniform loads only.
n

Upper values based on allowable panel strength.
Bottom values based on allowable service load deflection of L/180.

n

“-” denotes that capacities are limited by panel strength vs. deflection.

n

Steel con­forms to ASTM A792 (ZINCALUME®) 50,000 psi minimum yield.

n

Values are based on AISI S100-07/S2-10.

n

Maximum allowable outward load capacities are shown and dependent upon
fastener-to-substrate capacities. Refer to IAPMO-UES report #ER-0309 for
specific product capacities.

Specifications subject to change without notice.

Oil Canning
All flat metal surfaces can display waviness commonly referred to as
“oil canning”. “Oil canning” is an inherent characteristic of steel
products, not a defect, and therefore is not a cause for panel rejection.

Customer Service Centers
Tacoma, WA & Fontana, CA

Phone: 800-733-4955

Fax: 253-272-0791

For most current versions of literature please visit

www.aepspan.com

All information stated in the product sheet is correct at time of printing and subject to change without notice, check our website for the latest version.
©2007-2018 ASC Profiles LLC. All rights reserved. ZINCALUME® is registered trademark of BlueScope Steel Ltd. 0118 Printed in USA web (PS172)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Instance ID                     : uuid:04a68228-6fa2-482e-826c-5033f37e413d
Original Document ID            : adobe:docid:indd:67326834-44a9-11df-9ed2-ecf31876b2c3
Document ID                     : xmp.id:d68405a6-379e-1441-af41-200120129115
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:a4e25ce9-3ba8-bb4a-b7e5-9975053c89fa
Derived From Document ID        : xmp.did:b155fd7e-2974-0b4d-821e-abb2f3ce31c2
Derived From Original Document ID: adobe:docid:indd:67326834-44a9-11df-9ed2-ecf31876b2c3
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2018:01:10 11:03:40-08:00
Create Date                     : 2018:01:10 11:03:40-08:00
Modify Date                     : 2018:01:10 11:03:41-08:00
Metadata Date                   : 2018:01:10 11:03:41-08:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu