Design Span® hp Design Span hp is a performance-rated structural standing seam, concealed fastener metal roof system with net coverage of 12", 16", 17" & 18". Design Span hp is excellent as a roof over metal or wood decking, and as a fascia or mansard over plywood or supports. " " Optional Batten offers a clean bold look. Available with subtle striations for a clean pan (16", 17" & 18") 13⁄4″ 12", 16", & 17" Net Coverage (18" available – additional charges and lead times apply) Section Properties Width 12" 16" 17" 18" Gauge Base Steel Thickness (in) Yield (ksi) Tensile (ksi) Wt. (lbs/ft2) I+ (in4/ft) S+ (in3/ft) I(in3/ft) S(in3/ft) 24 0.0232 50 65 1.45 0.1185 0.0820 0.0762 0.0586 22 0.0294 50 65 1.83 0.1522 0.1080 0.0997 0.0771 24 0.0232 50 65 1.34 0.0943 0.0624 0.0593 0.0440 22 0.0294 50 65 1.68 0.1213 0.0825 0.0773 0.0580 24 0.0232 50 65 1.31 0.0901 0.0589 0.0562 0.0414 22 0.0294 50 65 1.65 0.1158 0.0779 0.0734 0.0546 24 0.0232 50 65 1.30 0.0858 0.0557 0.0533 0.0391 22 0.0294 50 65 1.63 0.1104 0.0737 0.0696 0.0515 NOTE: The hybrid positive moment of inertia, I, presented for determining deflection is: (2IEffective + IGross)/3 standard features n Factory applied sealant is a standard offer. n Custom manufactured sheet lengths from 6'-0" to 45'-0". n Subtle striations between ribs on 16" and wider panels. n Offered in 12", 16" & 17" widths. n Available in 24ga and 22ga in standard finishes Refer to AEP Span Color Charts for full range of color options, prints, textures, finishes and paint systems. n Recommended minimum slope of 2:12. Inquire for slopes below 2:12. n Tested in accordance with UL580-Class 90 & ASTM E1592. n Has been tested for air infiltration per ASTM E1680, and water infiltration per ASTM E1646. n Snap-together panel means no field seaming is required. n Panel evaluated by accredited third party. All structural performance data is contained within an IBC/IRC 2015 code compliance report. Customer Service Centers Tacoma, WA & Fontana, CA Phone: 800-733-4955 optional features n Short cut sheets from 6'-0" to 1'-0". Additional fees and lead times may apply. n Longer lengths available from 70'-0" (Tacoma, WA facility) to 100'-0" (Fontana, CA facility). Additional fees and lead times may apply. n Additional Batten option offers a clean bold look with the structural capacity and weather resistance of regular Design Span hp. n Factory notching available for turn under at the eave. n 18" width available. Additional fees and lead times may apply. Fax: 253-272-0791 For most current versions of literature please visit www.aepspan.com Design Span® hp 12" Design Span hp 16" Design Span hp Allowable Inward Loads (lbs/ft ) per Span (ft.-in.) Allowable Inward Loads (lbs/ft2) per Span (ft.-in.) 2 Gauge 24 Span 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" Single Span W/Ω 409 262 182 134 102 81 65 L/180 - - - - - - - Double Span W/Ω 285 184 128 94 72 57 46 L/180 - - - - - - - W/Ω 353 228 160 118 90 71 58 Triple Span Single Span 22 Cond. 2'-0" Double Span Triple Span L/180 - - - - - - - W/Ω 539 345 240 176 135 106 86 L/180 - - - - - - - W/Ω 377 243 169 124 96 76 61 L/180 - - - - - - - W/Ω 468 302 211 155 119 94 76 L/180 - - - - - - - Gauge 24 Span Cond. 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" Single Span W/Ω 309 199 138 102 78 62 50 L/180 - - - - - - - Double Span W/Ω 214 138 96 71 54 43 34 L/180 - - - - - - - W/Ω 265 171 119 88 67 53 43 Triple Span Single Span 22 Double Span Triple Span L/180 - - - - - - - W/Ω 412 263 183 134 103 81 66 L/180 - - - - - - - W/Ω 245 183 127 93 72 57 45 L/180 - - - - - - - W/Ω 278 223 158 117 90 70 57 L/180 - - - - - - - Allowable Outward Loads (lbs/ft2) per Span (ft.-in.) Allowable Outward Loads (lbs/ft2) per Span (ft.-in.) Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 24 82 76 71 67 63 59 56 52 48 24 49 42 36 30 29 29 29 28 28 22 82 76 71 67 63 59 56 52 48 22 74 66 58 49 49 48 47 47 46 LOADING TABLE LEGEND W/Ω - Allowable panel strength L - Span (Inches) L/180 - Load limited by a deflection of 1/180 of the span W - Distributed load 17" and 18" Design Span hp Allowable Inward Loads (lbs/ft2) per Span (ft.-in.) Gauge 24 22 Span Cond. 2'-0" Single Span f L/180 Double Span 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 275 178 124 91 70 55 44 - - - - - - - f 190 123 86 62 48 38 31 L/180 - - - - - - - Triple Span f 236 152 107 78 60 47 38 L/180 - - - - - - - Single Span f 368 235 164 120 92 73 59 L/180 - - - - - - - Double Span f 218 163 113 83 64 50 40 L/180 - - - - - - - f 247 198 141 103 79 63 51 L/180 - - - - - - - Triple Span Allowable Outward Loads (lbs/ft ) per Span (ft.-in.) 2 Gauge 1'-0" 1'-6" 2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 24 48 42 35 29 29 28 28 28 27 22 67 59 51 43 43 42 42 41 41 Single span Inward Loads Double span Triple span Outward Loads NOTES: n The information in these tables applies to uniform loads only. n Upper values based on allowable panel strength. Bottom values based on allowable service load deflection of L/180. n “-” denotes that capacities are limited by panel strength vs. deflection. n Steel conforms to ASTM A792 (ZINCALUME®) 50,000 psi minimum yield. n Values are based on AISI S100-07/S2-10. n Maximum allowable outward load capacities are shown and dependent upon fastener-to-substrate capacities. Refer to IAPMO-UES report #ER-0309 for specific product capacities. Specifications subject to change without notice. Oil Canning All flat metal surfaces can display waviness commonly referred to as “oil canning”. “Oil canning” is an inherent characteristic of steel products, not a defect, and therefore is not a cause for panel rejection. Customer Service Centers Tacoma, WA & Fontana, CA Phone: 800-733-4955 Fax: 253-272-0791 For most current versions of literature please visit www.aepspan.com All information stated in the product sheet is correct at time of printing and subject to change without notice, check our website for the latest version. ©2007-2018 ASC Profiles LLC. All rights reserved. ZINCALUME® is registered trademark of BlueScope Steel Ltd. 0118 Printed in USA web (PS172)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42 Instance ID : uuid:04a68228-6fa2-482e-826c-5033f37e413d Original Document ID : adobe:docid:indd:67326834-44a9-11df-9ed2-ecf31876b2c3 Document ID : xmp.id:d68405a6-379e-1441-af41-200120129115 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:a4e25ce9-3ba8-bb4a-b7e5-9975053c89fa Derived From Document ID : xmp.did:b155fd7e-2974-0b4d-821e-abb2f3ce31c2 Derived From Original Document ID: adobe:docid:indd:67326834-44a9-11df-9ed2-ecf31876b2c3 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2018:01:10 11:03:40-08:00 Create Date : 2018:01:10 11:03:40-08:00 Modify Date : 2018:01:10 11:03:41-08:00 Metadata Date : 2018:01:10 11:03:41-08:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools