612X Series And 633X Operating Detecto 6129 Clinical Scale Manual
User Manual: Detecto-6129-Clinical-Scale-Manual
Open the PDF directly: View PDF
.
Page Count: 16
| Download | |
| Open PDF In Browser | View PDF |
This Document is Hosted by: www.oldwillknottscales.com DIGITAL PHYSICIAN Waist-High Scale Model 6127 Series, 6129 Series and Eye-Level Scale Models 6337 and 6339 Operating Instructions 8525-M310-O1 Rev C 10/12 CARDINAL SCALE MFG. CO. PO BOX 151 x WEBB CITY, MO 64870 PH (417) 673-4631 x FAX (417) 673-5001 www.detectoscale.com Technical Support: Ph: 866-254-8261 x techsupport@cardet.com Printed in USA DIGITAL PHYSICIAN WAIST-HIGH / EYE-LEVEL SCALE Thank you for your purchase of our Detecto Digital Physician Waist-High or Detecto Digital Physician Eye-Level scale. It has been manufactured with quality and reliability at our factory in Webb City, MO USA. Your scale has been tested before leaving our factory to insure accuracy and dependability for years to come. This manual will guide you through assembly, installation, and operation of your scale. Please read it thoroughly before attempting to use your scale and keep it handy for future reference. FCC COMPLIANCE STATEMENT WARNING! This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference. You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4. All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk. Waist-High Eye-Level Capacity …...…..…...…… 550 lb x .2 lb 550 lb x .2 lb (250 kg x .1 kg), selectable (250 kg x .1 kg), selectable Platform Size ......…...….. 10 5/8” x 14 1/2” 10 5/8” x 14 1/2” (270 mm x 368 mm) (270 mm x 368 mm) Dimensions ..................... 10 7/8” W x 20 7/8” D x 37 7/8” H 10 7/8” W x 20 7/8” D x 57 1/2” H (276 mm x 530 mm x 962 mm) (276 mm x 530 mm x 1461 mm) Shipping Weight ……...… 34 lb (15.4 kg) 36 lb (16.3 kg) Scale Height ..…….…..... 37 1/2 ” (953 mm) 57 1/8” (1451 mm) Height Rod Measures ..... 6129, 6129KG, 6339 - 30” to 78” (76 cm to 200 cm) x inch/cm 6129KGM - 30” to 78” (76 cm to 200 cm) by 1/4”/1mm Display ….……………….. Six digit, Seven segment, 0.7 inch (17.8 mm) high LCD Power ....……………….... 6 “AA” size Alkaline, Ni-Cad or NiMH batteries (not included) OR an optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power adapter (Cardinal part number 6800-1045). Keyboard .…………......... Membrane type with 5 keys and 4 directional arrows Serial Number_______________________ Date of Purchase ____________________ Purchased Form_____________________ PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "WARNING" symbols: ___________________________________ ___________________________________ IMPORTANT RETAIN THIS INFORMATION FOR FUTURE USE 8525-M310-O1 Rev C x 612X Series and 633X Series ELECTRICAL WARNING 1 UNPACKING INSTRUCTIONS x Remove scale from carton by lifting up with equal force from column and platform base. x Check for any damage incurred in shipping. If scale has been damaged, place a claim with the carrier. Use the original carton and shipping material to return the scale. x Remove all plastic wrapping, foam fillers and cardboard material from the scale. x Remove and unpack the power supply and cord, if the scale was ordered with this option. x Carton contents: 1) 2) 3) 4) 5) Column Indicator Platform base Screws and lock washers Height measuring rod - optional NOTE! If column bracket is bent, straighten before assembling. ASSEMBLY INSTRUCTIONS Refer to Figures No. 1, 2, 3, and 4, then follow the instructions for scale assembly. 1. Carefully remove load cell and draft rod assembly from column. IMPORTANT! Handle load cell assembly with care! Do not drop, bend or twist. 2. Slip column over column bracket on platform base. Screw column to column brackets (two 1/4 truss head screws in front of column and four in the back). See Figure No. 1. 3. Referring to Figure No. 2, remove both #10-32 Truss Head Screws and lock washers securing the indicator bracket to the column. 4. Lower load cell and draft rod assembly into column. Draft Rod must pass through opening in column bracket. Referring to Figure No 1, make sure open end of lower draft rod hook is facing forward toward platform. 5. Next, referring to Figure No. 3, fasten top hook bolt of load cell assembly (C) to column. Make sure the load cell assembly does not touch the sides of column. 6. Slide grommet away from load cell assembly and slide into slot on column. NOTE! The slot should be on back (wide side) of column. 7. Pull excess load cell cable in column leaving enough slack in cable so as not to have any side pull on load cell. 8. Place digital indicator bracket on column and attach with 2 (#10-32) truss head screws and lock washers removed in step 3. See Figure No. 2. 9. Using a desk or table, lay down scale with column horizontal to floor. Raise draft rod keeping out of lever's way. Push lever. When lever is in position, hook draft rod around pivot. See Figure No. 4. 10. Attach indicator to indicator bracket on column, then connect load cell cable to back of indicator. Refer to the 750 Weight Indicator Owner’s Manual (8555-M483-O1) for additional information. 11. Scale is now ready for operation. 2 8525-M310-O1 Rev C x 612X Series and 633X Series ASSEMBLY INSTRUCTIONS, CONT. Grommet Load Cell Cable C Figure No. 1 Figure No. 3 Column Raise Draft Rod Draft Rod Push Lever Column Bracket Opening Figure No. 4 #10-32 Truss Head Screw Indicator Bracket Lock Washer Figure No. 2 8525-M310-O1 Rev C x 612X Series and 633X Series 3 4 8525-M310-O1 Rev C x 612X Series and 633X Series OPERATION DO NOT operate the keypad with pointed objects (pencils, pens, etc). Damage to keypad resulting from this practice is NOT covered under warranty. To Weigh 1. Set scale on any hard, level, flat surface or low-cut carpet. 2. Press ON/OFF key to turn on indicator. 3. Press ZERO key to zero weight display. The ZERO and lb or kg annunciator will turn on to show that scale is ready for use. 4. Place patient on scale and read weight display. 5. Remove patient from scale. Zero Weight Display 1. If the indicator is not showing zero weight on the display, press ZERO key. 2. Weight display will return to zero. ZERO, STABLE [\ and lb or kg annunciators will turn on to show a stable, center-of-zero weight condition. 750 Keypad Metric Conversion Press UNITS key to toggle between pounds and kilograms. Note that lb or kg annunciator will turn on to show which weighing unit is active. To Weigh and Calculate BMI 1. Press ON/OFF key to turn on indicator. 2. Press ZERO key to zero weight display. The ZERO and lb or kg annunciator will turn on to show that scale is ready for use. 3. Place patient on scale and read weight display. 4. Press BMI / ENTER key. 5. If pounds is the active weighing unit, display will change to show 5 FEET, 6 INCHES with the 6 blinking. (The blinking character is the position to be changed). a. Press a or b keys until desired height in inches is displayed and then press _ or ` key to move the blinking character to FEET. b. Press a or b keys until desired height in feet is displayed. c. Proceed to Step 7. 6. If kilograms is the active weighing unit, display will change to show 170 cm.with the 0 of 170 blinking. (The blinking character is the position to be changed). a. Press a or b keys until the desired number is displayed. b. Press _ or ` key to move to next character to change. c. Repeat steps A and B until the desired height in centimeters is displayed. d. Proceed to Step 7. 7. Press BMI / ENTER key. 8. Read BMI on display. 9. Remove patient from scale. 10. Press BMI / ENTER key to return to weighing operation. 8525-M310-O1 Rev C x 612X Series and 633X Series 5 HEIGHT ROD INSTRUCTIONS Height Rod Hole Location Please check the Height Rod hole locations before installing the Height Rod. x Some models may require holes to be drilled. x Please follow the measurements for drilling holes if necessary. x After holes have been drilled, please follow installation instructions. 2in (51mm) 9/64” 47/64” 29 (75.5 cm) IMPORTANT! Measure from bottom of column, not floor or scale base. 5 15/64” (13.3 cm) Height Rod Installation Height Rod 1. Remove the height rod, height rod brackets and hardware pack from the cardboard insert. 2. Attach the height rod brackets to the height rod using the four screws, lock washers and nuts enclosed in the hardware pack. Tighten all four screws. Height Rod Bracket 6 8525-M310-O1 Rev C x 612X Series and 633X Series (3.5mm) diameter holes, 1” (25.4mm) from center of column to center of hole HEIGHT ROD INSTRUCTIONS, CONT. 3. Place the large end of the slotted holes in the height rod brackets over the four hex head screws on the back of the column. Height Rod Bracket 4. Pull down to set the screws in the small end of the slotted hole and secure the bracket to the column. 5. Use the included wrench to tighten the hex head screws. Do not over-tighten the screws. Scale Column 8525-M310-O1 Rev C x 612X Series and 633X Series 7 HEIGHT ROD INSTRUCTIONS, CONT. Operation 1. Before patient steps onto scale platform, spoon should be rotated to horizontal position, and raised well above patient's apparent height. 2. Patient may now step onto scale platform. Spoon should be held horizontal and above patient's head. A B C E D 3. Carefully lower spoon, keeping it horizontal, until it rests gently on top of patient's head. If patient is shorter than 3' 4" (101.5 cm), push latch to right while simultaneously pushing down on spoon, until the spoon rests horizontally on top of patient's head. Height Rod in “rest” position 4. Read height of patient as follows: x If back of spoon points to outer height rod, then it points to correct height. x If back of spoon points to inner height rod, then correct height is read at top of outer height rod (see "Read" arrow on outer height rod). A = Latch B = Spoon C = Inner Height Rod D = Outer Height Rod E = Measurement “Read” Line 5. While holding spoon horizontally, raise spoon above patient's head. Patient may now step off scale platform. Hold spoon horizontal until patient is clear of height rod. 6. Rotate spoon back to vertical position and adjust height rod back to rest position (i.e. spoon should be locked in place within inner height rod and inner rod should be at its lowest position). 8 8525-M310-O1 Rev C x 612X Series and 633X Series ERROR AND STATUS DISPLAYS Display Meaning -Err-OF- General error, invalid keypad entry was attempted. -trL-UnS- Indicates an attempt to zero a weight outside scale zero range. CALib AdErr ErrAL ErrAH OCAP OFF Indicates calibration is necessary. Attempting to display a negative number greater than –9,999 or a positive number greater than 99,999. Motion is present when indicator is attempting to perform one of the following operations: Power Up Zero or Zero Weight Display. Consult your scale service representative. Scale weight exceeds scale capacity. Displayed to indicate indicator is turning off. CARE AND CLEANING OF SCALE x x x x x x DO NOT subject the platform to sudden shocks. DO NOT submerge indicator in water, pour or spray water directly on indicator. DO NOT use abrasive cleaners on this scale. DO NOT use acetone or other volatile solvents for cleaning. DO clean the scale and indicator using a damp soft cloth and mild detergent. DO avoid areas where the scale might be exposed to moisture. 8525-M310-O1 Rev C x 612X Series and 633X Series 9 PARTS IDENTIFICATION FINAL ASSEMBLY ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19* 20* 21* 22* QTY 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 2 6 6 2 1 1 1 1 1 PART NUMBER 3P1201X-1 430XG3R800 0044-C180-1A 709GR1206 0033-B254-08 0033-B256-08 3P8068 63K1038 6650-0087 0033-B438-0A 391RV204 6021-1454 6024-0004 0033-B104-0A 593R986 6024-0049 6024-0047 6021-1423 6021-1045 750 0033-D203-0A 0033-D475-0A 0033-D063-1A 6800-1045 DESCRIPTION BASE ASSEMBLY COLUMN ASSEMBLY FOR 6127(KG), 6129(KG) COLUMN ASSEMBLY FOR 6337, 6339 LOAD CELL ASSY DRAFT ROD FOR 6127(KG), 6129(KG) DRAFT ROD FOR 6337, 6339 PLATFORM COVER BASE LEG LABEL, MADE IN USA MOUNTING BRKT NUT ELASTIC STOP 1/4-20 Z/P SCW HEX HEAD 1/4 -20 X 3/4 WASHER FLAT 1/4 TOP PLATE ASSY. SERIAL TAG WASHER LOCK EXT #10 WASHER LOCK EXT 1/4 SCW TRUSS HEAD 1/4-20 X 1/2 SCW HEX HEAD #10-32 X 1/2 Z/P DIG. WT. INDICATOR HEIGHT ROD ASSEMBLY, INCH/CM FOR 6129(KG) HEIGHT ROD ASSEMBLY, 1/4”/1mm FOR 6129KGM HEIGHT ROD ASSEMBLY, INCH/CM FOR 6339 OPTIONAL AC ADAPTER 100-240VAC/12VDC @ 1A * NOT SHOWN 10 8525-M310-O1 Rev C x 612X Series and 633X Series PARTS IDENTIFICATION, CONT. BASE ASSEMBLY ITEM 1 2 3 4 5 6 7 8 9 10 11 15 16 QTY 1 4 1 2 2 4 1 1 4 1 1 6 6 PART NUMBER 3P2011X 3P2087 3P1001X 3P60 6021-0985 63K1038 2U58 3P8003X 3P8059 3P122 3P8002X 6024-0047 6021-1423 DESCRIPTION PLATFORM WELDMENT PLATFORM LOAD BEARING BASE WELDMENT CHECK PLATE HEX WASHER HD SCW #10 X 1/2 BASE LEG UNION CENTER HANGER SHORT LEVER ASSEMBLY UNION HANGER BUMPER LONG LEVER ASSEMBLY WASHER LOCK EXT 1/4 SCW TRUSS HEAD 1/4-20 X 1/2 8525-M310-O1 Rev C x 612X Series and 633X Series 11 STATEMENT OF LIMITED WARRANTY Detecto Scale warrants its equipment to be free from defects in material and workmanship as follows: Detecto warrants to the original purchaser only that it will repair or replace any part of equipment which is defective in material or workmanship for a period of one (1) year from date of shipment. Detecto shall be the sole judge of what constitutes a defect. During the first ninety (90) days Detecto may choose to supply all necessary replacement parts and service during normal weekday working hours at no charge to the buyer. After the first ninety (90) days Detecto will supply parts and service at the job site provided the owner agrees to pay the Dealer for all travel time, including mileage and test equipment, as well as any expenses incurred over the direct labor of the technician at the job site. This limited warranty honors only labor performed by Detecto authorized dealers. This warranty does not apply to peripheral equipment not manufactured by Detecto; this equipment will be covered by certain manufacturer’s warranty only. This warranty does not include replacement of expendable or consumable parts. This does not apply to any item which has deteriorated or damaged due to wear, accident, misuse, abuse, improper line voltage, overloading, theft, lightning, fire, water or acts of God, or due to extended storage or exposure while in purchaser’s possession. This warranty does not apply to maintenance service. Purchased parts will have a ninety (90) day repair or replacement warranty only. Detecto may require components be returned to the factory; they must be properly packed and shipping charges prepaid. A return authorization number must be obtained for all returns and marked on the outside of all returned packages. Detecto accepts no responsibility for loss or damage in transit. 12 8525-M310-O1 Rev C x 612X Series and 633X Series STATEMENT OF LIMITED WARRANTY Conditions Which Void Limited Warranty This warranty shall not apply to equipment which: A.) Has been tampered with, defaced, mishandled or have had repairs and modifications not authorized by Detecto. B.) Has had serial number altered, defaced, or removed. C.) Has not been grounded according to Detecto’s recommended procedure. Freight Carrier Damage Claims for equipment damaged in transit must be referred to the freight carrier in accordance with freight carrier regulations. This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of the product. Detecto will not be liable for consequential damages of any nature, including but not limited to, loss of profit, delays or expenses, whether based on tort or contract. Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured. The foregoing is in lieu of all other warranties, express or implied including any warranty that extends beyond the description of the product including any warranty of merchantability or fitness for a particular purpose. This warranty covers only those Detecto products installed in the forty-eight (48) contiguous continental United States. Ph. (800) 641-2008 E-mail: detecto@cardet.com 203 E. Daugherty Webb City, MO 64870 8525-M310-O1 Rev C x 612X Series and 633X Series 02/06 Printed in USA D268-WARRANTY-DET 13 14 8525-M310-O1 Rev C x 612X Series and 633X Series
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Creator Tool : Acrobat PDFMaker 9.1 for Word Modify Date : 2013:03:06 08:48:28-07:00 Create Date : 2012:10:15 16:46:02-05:00 Metadata Date : 2013:03:06 08:48:28-07:00 Producer : Acrobat Distiller 9.5.2 (Windows) Keywords : Format : application/pdf Creator : Technical Writer Title : 612X Series and 633X Series Operating Description : Document ID : uuid:c4e0fe6f-ff12-4d2c-86f1-1674423eb91a Instance ID : uuid:cb6b2322-df15-4022-a9dd-ecca8dfc2659 Subject : 83 Company : Cardinal Scale Mfg. Co. Comments : Source Modified : D:20121008184149 Has XFA : No Page Count : 16 Author : Technical WriterEXIF Metadata provided by EXIF.tools