612X Series And 633X Operating Detecto 6129 Clinical Scale Manual

User Manual: Detecto-6129-Clinical-Scale-Manual

Open the PDF directly: View PDF PDF.
Page Count: 16

Download612X Series And 633X Operating Detecto-6129-Clinical-Scale-Manual
Open PDF In BrowserView PDF
This Document is Hosted by: www.oldwillknottscales.com

DIGITAL PHYSICIAN
Waist-High Scale
Model 6127 Series, 6129 Series
and

Eye-Level Scale
Models 6337 and 6339
Operating Instructions

8525-M310-O1 Rev C
10/12

CARDINAL SCALE MFG. CO.
PO BOX 151 x WEBB CITY, MO 64870
PH (417) 673-4631 x FAX (417) 673-5001
www.detectoscale.com

Technical Support: Ph: 866-254-8261 x techsupport@cardet.com

Printed in USA

DIGITAL PHYSICIAN WAIST-HIGH / EYE-LEVEL SCALE
Thank you for your purchase of our Detecto Digital Physician Waist-High or Detecto Digital
Physician Eye-Level scale. It has been manufactured with quality and reliability at our factory in
Webb City, MO USA. Your scale has been tested before leaving our factory to insure accuracy
and dependability for years to come.
This manual will guide you through assembly, installation, and operation of your scale. Please
read it thoroughly before attempting to use your scale and keep it handy for future reference.
FCC COMPLIANCE STATEMENT
WARNING! This equipment generates uses and can radiate radio frequency and if not installed
and used in accordance with the instruction manual, may cause interference to radio
communications. It has been tested and found to comply with the limits for a Class A computing
device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable
protection against such interference when operated in a commercial environment. Operation of
this equipment in a residential area may cause interference in which case the user will be
responsible to take whatever measures necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems"
prepared by the Federal Communications Commission helpful. It is available from the U.S.
Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4.
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any
manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While
every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or
omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All
instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in
working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is
not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any
damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so
entirely at their own risk.

Waist-High
Eye-Level
Capacity …...…..…...…… 550 lb x .2 lb
550 lb x .2 lb
(250 kg x .1 kg), selectable
(250 kg x .1 kg), selectable
Platform Size ......…...….. 10 5/8” x 14 1/2”
10 5/8” x 14 1/2”
(270 mm x 368 mm)
(270 mm x 368 mm)
Dimensions ..................... 10 7/8” W x 20 7/8” D x 37 7/8” H 10 7/8” W x 20 7/8” D x 57 1/2” H
(276 mm x 530 mm x 962 mm)
(276 mm x 530 mm x 1461 mm)
Shipping Weight ……...… 34 lb (15.4 kg)
36 lb (16.3 kg)
Scale Height ..…….…..... 37 1/2 ” (953 mm)
57 1/8” (1451 mm)
Height Rod Measures ..... 6129, 6129KG, 6339 - 30” to 78” (76 cm to 200 cm) x inch/cm
6129KGM - 30” to 78” (76 cm to 200 cm) by 1/4”/1mm
Display ….……………….. Six digit, Seven segment, 0.7 inch (17.8 mm) high LCD
Power ....……………….... 6 “AA” size Alkaline, Ni-Cad or NiMH batteries (not included) OR an
optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA
listed AC power adapter (Cardinal part number 6800-1045).
Keyboard .…………......... Membrane type with 5 keys and 4 directional arrows

Serial Number_______________________
Date of Purchase ____________________
Purchased Form_____________________

PRECAUTIONS
Before using this instrument, read this
manual and pay special attention to all
"WARNING" symbols:

___________________________________
___________________________________

IMPORTANT

RETAIN THIS INFORMATION FOR FUTURE USE

8525-M310-O1 Rev C x 612X Series and 633X Series

ELECTRICAL
WARNING

1

UNPACKING INSTRUCTIONS
x

Remove scale from carton by lifting up with equal force from column and platform base.

x

Check for any damage incurred in shipping. If scale has been damaged, place a claim with the
carrier. Use the original carton and shipping material to return the scale.

x

Remove all plastic wrapping, foam fillers and cardboard material from the scale.

x

Remove and unpack the power supply and cord, if the scale was ordered with this option.

x

Carton contents:
1)
2)
3)
4)
5)

Column
Indicator
Platform base
Screws and lock washers
Height measuring rod - optional

NOTE! If column bracket is bent,
straighten before assembling.

ASSEMBLY INSTRUCTIONS
Refer to Figures No. 1, 2, 3, and 4, then follow the instructions for scale assembly.
1. Carefully remove load cell and draft rod assembly from column.
IMPORTANT! Handle load cell assembly with care! Do not drop, bend or twist.
2. Slip column over column bracket on platform base. Screw column to column brackets (two
1/4 truss head screws in front of column and four in the back). See Figure No. 1.
3. Referring to Figure No. 2, remove both #10-32 Truss Head Screws and lock washers
securing the indicator bracket to the column.
4. Lower load cell and draft rod assembly into column. Draft Rod must pass through opening in
column bracket. Referring to Figure No 1, make sure open end of lower draft rod hook is
facing forward toward platform.
5. Next, referring to Figure No. 3, fasten top hook bolt of load cell assembly (C) to column.
Make sure the load cell assembly does not touch the sides of column.
6. Slide grommet away from load cell assembly and slide into slot on column. NOTE! The slot
should be on back (wide side) of column.
7. Pull excess load cell cable in column leaving enough slack in cable so as not to have any
side pull on load cell.
8. Place digital indicator bracket on column and attach with 2 (#10-32) truss head screws and
lock washers removed in step 3. See Figure No. 2.
9. Using a desk or table, lay down scale with column horizontal to floor. Raise draft rod
keeping out of lever's way. Push lever. When lever is in position, hook draft rod around
pivot. See Figure No. 4.
10. Attach indicator to indicator bracket on column, then connect load cell cable to back of
indicator. Refer to the 750 Weight Indicator Owner’s Manual (8555-M483-O1) for additional
information.
11. Scale is now ready for operation.

2

8525-M310-O1 Rev C x 612X Series and 633X Series

ASSEMBLY INSTRUCTIONS, CONT.
Grommet

Load
Cell
Cable

C

Figure No. 1
Figure No. 3
Column

Raise
Draft
Rod
Draft
Rod

Push
Lever

Column
Bracket

Opening

Figure No. 4
#10-32 Truss
Head Screw
Indicator
Bracket

Lock
Washer

Figure No. 2

8525-M310-O1 Rev C x 612X Series and 633X Series

3

4

8525-M310-O1 Rev C x 612X Series and 633X Series

OPERATION
DO NOT operate the keypad with pointed objects (pencils, pens, etc).
Damage to keypad resulting from this practice is NOT covered under warranty.

To Weigh
1. Set scale on any hard, level, flat
surface or low-cut carpet.
2. Press ON/OFF key to turn on
indicator.
3. Press ZERO key to zero weight
display. The ZERO and lb or kg
annunciator will turn on to show that
scale is ready for use.
4. Place patient on scale and read
weight display.
5. Remove patient from scale.

Zero Weight Display
1. If the indicator is not showing zero
weight on the display, press ZERO
key.
2. Weight display will return to zero.
ZERO, STABLE [\ and lb or kg
annunciators will turn on to show a
stable, center-of-zero weight condition.
750 Keypad

Metric Conversion
Press UNITS key to toggle between pounds and kilograms. Note that lb or kg annunciator
will turn on to show which weighing unit is active.

To Weigh and Calculate BMI
1. Press ON/OFF key to turn on indicator.
2. Press ZERO key to zero weight display. The ZERO and lb or kg annunciator will turn on to
show that scale is ready for use.
3. Place patient on scale and read weight display.
4. Press BMI / ENTER key.
5. If pounds is the active weighing unit, display will change to show 5 FEET, 6 INCHES with the 6
blinking. (The blinking character is the position to be changed).
a. Press a or b keys until desired height in inches is displayed and then press _ or `
key to move the blinking character to FEET.
b. Press a or b keys until desired height in feet is displayed.
c. Proceed to Step 7.
6. If kilograms is the active weighing unit, display will change to show 170 cm.with the 0 of 170
blinking. (The blinking character is the position to be changed).
a. Press a or b keys until the desired number is displayed.
b. Press _ or ` key to move to next character to change.
c. Repeat steps A and B until the desired height in centimeters is displayed.
d. Proceed to Step 7.
7. Press BMI / ENTER key.
8. Read BMI on display.
9. Remove patient from scale.
10. Press BMI / ENTER key to return to weighing operation.
8525-M310-O1 Rev C x 612X Series and 633X Series

5

HEIGHT ROD INSTRUCTIONS
Height Rod Hole Location
Please check the Height Rod hole
locations before installing the Height Rod.

x

Some models may require holes to
be drilled.

x

Please follow the measurements for
drilling holes if necessary.

x

After holes have been drilled, please
follow installation instructions.

2in (51mm)

9/64”

47/64”

29
(75.5 cm)

IMPORTANT!
Measure from bottom of column,
not floor or scale base.

5 15/64”
(13.3 cm)

Height Rod Installation
Height Rod
1. Remove the height rod, height rod
brackets and hardware pack from
the cardboard insert.

2. Attach the height rod brackets to
the height rod using the four
screws, lock washers and nuts
enclosed in the hardware pack.
Tighten all four screws.
Height Rod
Bracket

6

8525-M310-O1 Rev C x 612X Series and 633X Series

(3.5mm)
diameter holes,
1” (25.4mm) from
center of column
to center of hole

HEIGHT ROD INSTRUCTIONS, CONT.
3. Place the large end of the slotted
holes in the height rod brackets over
the four hex head screws on the back
of the column.

Height Rod
Bracket

4. Pull down to set the screws in the
small end of the slotted hole and
secure the bracket to the column.

5. Use the included wrench to tighten the
hex head screws. Do not over-tighten
the screws.

Scale
Column

8525-M310-O1 Rev C x 612X Series and 633X Series

7

HEIGHT ROD INSTRUCTIONS, CONT.
Operation
1. Before patient steps onto scale platform,
spoon should be rotated to horizontal position,
and raised well above patient's apparent
height.
2. Patient may now step onto scale platform.
Spoon should be held horizontal and above
patient's head.

A
B

C
E

D

3. Carefully lower spoon, keeping it horizontal,
until it rests gently on top of patient's head. If
patient is shorter than 3' 4" (101.5 cm), push
latch to right while simultaneously pushing
down on spoon, until the spoon rests
horizontally on top of patient's head.

Height Rod in
“rest” position

4. Read height of patient as follows:
x

If back of spoon points to outer height rod,
then it points to correct height.

x

If back of spoon points to inner height rod,
then correct height is read at top of outer
height rod (see "Read" arrow on outer
height rod).

A = Latch
B = Spoon
C = Inner Height Rod
D = Outer Height Rod
E = Measurement
“Read” Line

5. While holding spoon horizontally, raise spoon above patient's head. Patient may now step off
scale platform. Hold spoon horizontal until patient is clear of height rod.
6. Rotate spoon back to vertical position and adjust height rod back to rest position (i.e. spoon
should be locked in place within inner height rod and inner rod should be at its lowest position).

8

8525-M310-O1 Rev C x 612X Series and 633X Series

ERROR AND STATUS DISPLAYS
Display

Meaning

-Err-OF-

General error, invalid keypad entry was attempted.

-trL-UnS-

Indicates an attempt to zero a weight outside scale zero range.

CALib
AdErr
ErrAL
ErrAH
OCAP
OFF

Indicates calibration is necessary.

Attempting to display a negative number greater than –9,999 or a
positive number greater than 99,999.
Motion is present when indicator is attempting to perform one of the
following operations: Power Up Zero or Zero Weight Display.

Consult your scale service representative.
Scale weight exceeds scale capacity.
Displayed to indicate indicator is turning off.

CARE AND CLEANING OF SCALE
x
x
x
x
x
x

DO NOT subject the platform to sudden shocks.
DO NOT submerge indicator in water, pour or spray water directly on indicator.
DO NOT use abrasive cleaners on this scale.
DO NOT use acetone or other volatile solvents for cleaning.
DO clean the scale and indicator using a damp soft cloth and mild detergent.
DO avoid areas where the scale might be exposed to moisture.

8525-M310-O1 Rev C x 612X Series and 633X Series

9

PARTS IDENTIFICATION
FINAL ASSEMBLY

ITEM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19*
20*
21*
22*

QTY
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
2
6
6
2
1
1
1
1
1

PART NUMBER
3P1201X-1
430XG3R800
0044-C180-1A
709GR1206
0033-B254-08
0033-B256-08
3P8068
63K1038
6650-0087
0033-B438-0A
391RV204
6021-1454
6024-0004
0033-B104-0A
593R986
6024-0049
6024-0047
6021-1423
6021-1045
750
0033-D203-0A
0033-D475-0A
0033-D063-1A
6800-1045

DESCRIPTION
BASE ASSEMBLY
COLUMN ASSEMBLY FOR 6127(KG), 6129(KG)
COLUMN ASSEMBLY FOR 6337, 6339
LOAD CELL ASSY
DRAFT ROD FOR 6127(KG), 6129(KG)
DRAFT ROD FOR 6337, 6339
PLATFORM COVER
BASE LEG
LABEL, MADE IN USA
MOUNTING BRKT
NUT ELASTIC STOP 1/4-20 Z/P
SCW HEX HEAD 1/4 -20 X 3/4
WASHER FLAT 1/4
TOP PLATE ASSY.
SERIAL TAG
WASHER LOCK EXT #10
WASHER LOCK EXT 1/4
SCW TRUSS HEAD 1/4-20 X 1/2
SCW HEX HEAD #10-32 X 1/2 Z/P
DIG. WT. INDICATOR
HEIGHT ROD ASSEMBLY, INCH/CM FOR 6129(KG)
HEIGHT ROD ASSEMBLY, 1/4”/1mm FOR 6129KGM
HEIGHT ROD ASSEMBLY, INCH/CM FOR 6339
OPTIONAL AC ADAPTER 100-240VAC/12VDC @ 1A

* NOT SHOWN
10

8525-M310-O1 Rev C x 612X Series and 633X Series

PARTS IDENTIFICATION, CONT.
BASE ASSEMBLY

ITEM
1
2
3
4
5
6
7
8
9
10
11
15
16

QTY
1
4
1
2
2
4
1
1
4
1
1
6
6

PART NUMBER
3P2011X
3P2087
3P1001X
3P60
6021-0985
63K1038
2U58
3P8003X
3P8059
3P122
3P8002X
6024-0047
6021-1423

DESCRIPTION
PLATFORM WELDMENT
PLATFORM LOAD BEARING
BASE WELDMENT
CHECK PLATE
HEX WASHER HD SCW #10 X 1/2
BASE LEG
UNION CENTER HANGER
SHORT LEVER ASSEMBLY
UNION HANGER
BUMPER
LONG LEVER ASSEMBLY
WASHER LOCK EXT 1/4
SCW TRUSS HEAD 1/4-20 X 1/2

8525-M310-O1 Rev C x 612X Series and 633X Series

11

STATEMENT OF LIMITED WARRANTY
Detecto Scale warrants its equipment to be free from defects in
material and workmanship as follows: Detecto warrants to the original
purchaser only that it will repair or replace any part of equipment which
is defective in material or workmanship for a period of one (1) year
from date of shipment. Detecto shall be the sole judge of what
constitutes a defect.
During the first ninety (90) days Detecto may choose to supply all
necessary replacement parts and service during normal weekday
working hours at no charge to the buyer.
After the first ninety (90) days Detecto will supply parts and service at
the job site provided the owner agrees to pay the Dealer for all travel
time, including mileage and test equipment, as well as any expenses
incurred over the direct labor of the technician at the job site. This
limited warranty honors only labor performed by Detecto authorized
dealers.
This warranty does not apply to peripheral equipment not manufactured
by Detecto; this equipment will be covered by certain manufacturer’s
warranty only.
This warranty does not include replacement of expendable or
consumable parts. This does not apply to any item which has
deteriorated or damaged due to wear, accident, misuse, abuse,
improper line voltage, overloading, theft, lightning, fire, water or acts of
God, or due to extended storage or exposure while in purchaser’s
possession. This warranty does not apply to maintenance service.
Purchased parts will have a ninety (90) day repair or replacement
warranty only.
Detecto may require components be returned to the factory; they must
be properly packed and shipping charges prepaid. A return
authorization number must be obtained for all returns and marked on
the outside of all returned packages. Detecto accepts no responsibility
for loss or damage in transit.

12

8525-M310-O1 Rev C x 612X Series and 633X Series

STATEMENT OF LIMITED WARRANTY
Conditions Which Void Limited Warranty
This warranty shall not apply to equipment which:
A.) Has been tampered with, defaced, mishandled or have had repairs
and modifications not authorized by Detecto.
B.) Has had serial number altered, defaced, or removed.
C.) Has not been grounded according to Detecto’s recommended
procedure.

Freight Carrier Damage
Claims for equipment damaged in transit must be referred to the freight
carrier in accordance with freight carrier regulations.
This warranty sets forth the extent of our liability for breach of any
warranty or deficiency in connection with the sale or use of the product.
Detecto will not be liable for consequential damages of any nature,
including but not limited to, loss of profit, delays or expenses, whether
based on tort or contract. Detecto reserves the right to incorporate
improvements in material and design without notice and is not obligated
to incorporate improvements in equipment previously manufactured.
The foregoing is in lieu of all other warranties, express or implied
including any warranty that extends beyond the description of the
product including any warranty of merchantability or fitness for a
particular purpose. This warranty covers only those Detecto products
installed in the forty-eight (48) contiguous continental United States.

Ph. (800) 641-2008
E-mail: detecto@cardet.com
203 E. Daugherty
Webb City, MO 64870

8525-M310-O1 Rev C x 612X Series and 633X Series

02/06
Printed in USA
D268-WARRANTY-DET

13

14

8525-M310-O1 Rev C x 612X Series and 633X Series



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Modify Date                     : 2013:03:06 08:48:28-07:00
Create Date                     : 2012:10:15 16:46:02-05:00
Metadata Date                   : 2013:03:06 08:48:28-07:00
Producer                        : Acrobat Distiller 9.5.2 (Windows)
Keywords                        : 
Format                          : application/pdf
Creator                         : Technical Writer
Title                           : 612X Series and 633X Series Operating
Description                     : 
Document ID                     : uuid:c4e0fe6f-ff12-4d2c-86f1-1674423eb91a
Instance ID                     : uuid:cb6b2322-df15-4022-a9dd-ecca8dfc2659
Subject                         : 83
Company                         : Cardinal Scale Mfg. Co.
Comments                        : 
Source Modified                 : D:20121008184149
Has XFA                         : No
Page Count                      : 16
Author                          : Technical Writer
EXIF Metadata provided by EXIF.tools

Navigation menu