Digi Sm110 Label Printing Scale User Manual
User Manual: Digi-sm110-Label-Printing-Scale-User-Manual
Open the PDF directly: View PDF .
Page Count: 147
Download | |
Open PDF In Browser | View PDF |
OPERATION MANUAL MODEL : SM-110 EDITION st 1 2nd 3rd 4th Month Year January 2008__ ___________ ___________ _____ SHANGHAI TERAOKA ELECTRONIC CO., LTD TECHNICAL SUPPORT DEPARTMENT 3rd Floor of 2nd Building, Jia Yuan Business Center, 51# Long Wu Road, Shanghai China 200232. TEL : +86-21-6408-5151 FAX : +86-21-6408-3468 EMAIL ADDRESS :steservice@digi-scale.com Notice Welcome to use DIGI’s product. Please see the operation manual and learn how to use our products. Thank you! Table of Content 1. GENERAL ......................................................................................................................1 1.1 Overall View ......................................................................................................1 1.2 Display Panel .....................................................................................................3 1.3 Key Panel ...........................................................................................................3 1.4 Thermal Printer Head ......................................................................................8 1.5 Features ..............................................................................................................9 1.6 Specifications .................................................................................................. 10 1.6.1 Display ........................................................................................................................................................10 1.6.2 Operating Conditions .....................................................................................................................10 1.6.3 Dimensions .............................................................................................................................................10 1.7 Label Type....................................................................................................... 11 2. INITIAL SETUP.....................................................................................................12 2.1 Setup ................................................................................................................ 12 2.2 Location of Switches and Connectors........................................................ 14 2.3 Mode Change.................................................................................................. 14 2.4 Memory Initialization .................................................................................... 15 2.5 Specification Setting ...................................................................................... 15 2.6 Password Setting........................................................................................... 16 2.6.1 Procedures of Password Setting .............................................................................................16 2.6.2 Password Using ....................................................................................................................................16 2.7 Clear Files........................................................................................................ 17 3. PROGRAM MODE ...............................................................................................18 3.1 Programmable Files....................................................................................... 18 3.2 General Explanation...................................................................................... 19 3.3 Department Files ........................................................................................... 20 3.3.1 Program Department File ...........................................................................................................20 3.3.2 Delete Department File.................................................................................................................21 3.4 Main Group Files........................................................................................... 22 3.4.1 Program Main Group File...........................................................................................................22 3.4.2 Delete Main Group File ................................................................................................................23 3.5 Program / Skip Item Data ........................................................................... 24 3.6 PLU Programming ........................................................................................ 26 3.6.1 Program PLU File(weighing item) ........................................................................................30 3.6.2 Program PLU File(non-weighing item).............................................................................33 3.6.3 PLU [COPY] Function ..................................................................................................................37 3.6.4 Delete PLU File ...................................................................................................................................38 3.6.5 Volume Discount & Mark Down print function.......................................................39 3.7 Memory Status................................................................................................ 41 3.8 Key Assignment ............................................................................................. 42 3.8.1 PLU Assignment.................................................................................................................................42 3.8.2 Function Key Assignment ...........................................................................................................42 3.8.3 Delete Preset Key Assignment ................................................................................................43 3.9 Shop Name File.............................................................................................. 44 3.9.1 Program Shop Name File ............................................................................................................44 3.9.2 Delete Shop Name File .................................................................................................................45 3.10 Advertisement File ...................................................................................... 46 3.10.1 Program Advertisement File...................................................................................................46 3.10.2 Delete Advertisement File ........................................................................................................47 3.11 Vender File.................................................................................................... 48 3.12 Program Date And Time............................................................................ 49 3.13 Special Message File .................................................................................... 50 3.13.1 Program Special Message File ...............................................................................................50 3.13.2 Delete Special Message File.....................................................................................................51 3.14 Ingredient File .............................................................................................. 52 3.14.1 Program Ingredient File .............................................................................................................52 3.14.2 Delete Ingredient File ..................................................................................................................53 3.15 Text File ........................................................................................................ 54 3.15.1 Program Text File ...........................................................................................................................54 3.15.2 Delete Text File.................................................................................................................................55 3.16 Free Format File .......................................................................................... 56 3.16.1 General Information.....................................................................................................................56 3.16.2 Print Area, Print Position and Print Angles ................................................................57 3.16.3 Programming Parameter Of Print Items......................................................................59 3.16.4 Free Format Entry..........................................................................................................................61 3.16.5 Free Format Copy Function ...................................................................................................66 3.16.6 Free Format Delete Function ................................................................................................66 3.16.7 Sample of program a format by modifying the existing format ................67 3.17 Place File ....................................................................................................... 70 3.17.1 Program Place File .........................................................................................................................70 3.17.2 Delete Place File...............................................................................................................................70 3.18 Machine Setting............................................................................................ 71 3.19 Logo File ....................................................................................................... 72 3.19.1 Pre-programming Logo Data ................................................................................................72 3.19.2 Program Display & Keys Function ...................................................................................73 3.19.3 Programming Order......................................................................................................................74 3.19.4 Program Logo File .........................................................................................................................74 3.19.5 Delete Logo File ..............................................................................................................................75 3.20 Tax File.......................................................................................................... 76 3.20.1 Program Tax File .............................................................................................................................76 3.20.2 Delete Tax File ..................................................................................................................................77 3.21 Scroll Message File ...................................................................................... 78 3.21.1 Program Scroll Message File ..................................................................................................78 3.21.2 Delete Scroll Message File........................................................................................................78 3.22 Scroll Sequence File..................................................................................... 79 3.22.1 Program Scroll Sequence File ................................................................................................79 3.22.2 Enable or Disable Scroll Sequence File .........................................................................80 3.22.3 Delete Scroll Sequence Number ..........................................................................................81 3.23 ASCII Character Input Method ................................................................ 82 3.24 ASCII Code Input Method........................................................................ 83 4. REGISTRATION MODE .............................................................................. 84 4.1 ON/OFF ........................................................................................................ 84 4.2 Reset and Weighing Check........................................................................... 84 4.3 Tare Subtraction............................................................................................. 85 4.3.1 One touch Tare Subtraction ......................................................................................................85 4.3.2 Digital tare Subtraction ..................................................................................................................85 4.4 PLU Call Up ................................................................................................... 86 4.4.1 Manual PLU Call Up .......................................................................................................................86 4.4.2 PLU Call Up by Preset Key........................................................................................................86 4.4.3 PLU Call by Numeric Key (Auto PLU Call) .................................................................86 4.5 Fix Operation ................................................................................................. 87 4.5.1 Fix Tare by FIX Key ........................................................................................................................87 4.5.2 Fix PLU by FIX Key .......................................................................................................................87 4.5.3 Fix Unit Price by FIX Key ..........................................................................................................87 4.6 Operation Mode Change .............................................................................. 88 4.7 Item Label Printing in Manual Mode ......................................................... 89 4.7.1 Label Printing for PLU Item .....................................................................................................89 4.7.2 Label Printing for NON-PLU Item.....................................................................................90 4.8 Total Label Printing in Manual Mode ........................................................ 91 4.8.1 Sales Transaction ................................................................................................................................91 4.8.2 [PRICE DISCOUNT] Function Key in Add Mode ...............................................92 4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode ........................................92 4.9 Data Correction.............................................................................................. 93 4.9.1 On The Spot Correction ..............................................................................................................93 4.9.2 Void by Item Correction...............................................................................................................94 4.10 Item Label Printing in Pre-pack Mode .................................................... 95 4.10.1 Item Label Issue for PLU Item ............................................................................................95 4.10.2 Item Label Issue for NON-PLU Item............................................................................96 5. READ REPORT MODE ................................................................................. 97 5.1 Report Factor Select...................................................................................... 97 5.2 Report Type Selection................................................................................... 97 5.2.1 Main Group Report..........................................................................................................................99 5.2.2 PLU Report ............................................................................................................................................99 5.2.3 Department Report ........................................................................................................................100 5.2.4 Sales Report ........................................................................................................................................101 5.2.5 24Hour Report ...................................................................................................................................101 5.2.6 ABC Report ..........................................................................................................................................101 5.2.7 Clerk Report .........................................................................................................................................102 5.2.8 Pre-pack Report.................................................................................................................................103 5.2.9 Tax Report .............................................................................................................................................104 5.2.10 Store Summarized Report.......................................................................................................104 6. RESET REPORT MODE ............................................................................. 105 7. Apendix ......................................................................................................................... 106 A. Specification List B. Flexible Barcode Setting Guide C. Traceability Setting Guide D. Nutrition Setting Guide E. Operational Menu Tree SM 110 GENERAL 1. GENERAL 1.1 Overall View z Bench Type z Pole Type 1 SM 110 GENERAL 1.2 Display Panel z 25 digits × 19 segments TN type LCD z 32 × 202 full dot Martix Green LCD 1.3 Key Panel z 32 Preset Keys Type z 56 Preset Keys Type 2 SM 110 GENERAL ON/OFF KEY Turn display "ON" or "OFF". PRESET KEY P1 ~ P40 (B) P1 ~ P74 (EV) Set up or call either unit price and tare value. NUMERIC KEYS 0~9 Enter numeric data. TARE KEY Set or Clear Tare value. Select "NO" in S and Z Mode. Item test print in S Mode. CLEAR KEY C For Back space or Clear numeric value. Select "YES" in S and Z Mode. RE-ZERO KEY Reset weight to ZERO. PREPACK KEY AUTO Switch Manual mode and Pre-pack mode alternatively. (The mode status will be indicated in the P and M indicator.) ▪P - PRE-PACK MODE ▪ M - MANUAL MODE CHANGE KEY Calculate the Changed Amount. Escape the Programming screen without saving data in S Mode. 3 SM 110 GENERAL MULTIPLLE KEY Register the number of Non-Weight products. X Select programming item such as PLU data, Shop Name in S Mode. Select Report Type in X Mode. Select Data Transaction Type in Z Mode. CLERK KEY V1~V4 Accumulate the Total Price. VOID KEY − Correct the sales data. PLU KEY PLU Call up PLU data in R Mode. Store the programmed data in S Mode. FEED KEY Feed Label or Receipt paper PRINT KEY Print out Label or Receipt. 6 SM 110 GENERAL MODE SELECT KEY Five Modes can be selected using this key. • Indicator R - REGISTRATION MODE (All the sales transactions are performed.) • Indicator X - CHECK MODE (Printing out and sales report.) • Indicator S - PROGRAM MODE (Programming preset data, such as products, data, shop name, etc.) • Indicator Z - TOTAL MODE (Clear sales data stored.) • Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X, S, Z mode, set PASSWORD for PASSWORD MODE when all indicators(R, X, S, Z) blink) Decrease/Increase Specification Count key 《,》 Decrease/Increase Only used when Setting SPEC 141 & 142 <<,>> Select parameter data such as SPEC data. Move cursor left or right. 7 SM 110 GENERAL 1.4 Thermal Printer Head z z Thermal Head Model: TDK LHE4253SU Max Printing With: 56mm z Compare of Two Thermal Head Types of SM Series Scales SM-100, SM-80L, SM-300 Thermal Head Model TDK LHE4253SU Max Printing Width 56mm Thermal Head Photo 8 SM-80, SM-500 TDK LH-3139K 60mm SM 110 GENERAL 1.5 Features y Digital printing scale consists of electronic cash registers function and label printing function. y High-speed, high reliability thermal head printer. y Easy paper handing achieved special designed mechanism. y Built-in clock automatically updates data and time. y Quick response to weight changes. y Capacity : 15lb and 30lb. y Resolution : Display Resolution 1/3, 000 : Internal Resolution 1/90,000 y Calibrating by software. y y Customer and operator display (optional customer pole display). 25 digits x 19 segments TN type LCD with back-light for numeric digit and character display. 32 x 202 full dot Martix Green LCD display. y 55/83 membrane keys a. ON/OFF key b. 10 Numeric keys, to key in numeric data. c. 32/56 Preset keys, to preset PLU or function into the key. d. 23/27 Operational keys, to perform various functional operations. y 18 data files for Department, Main Group, PLU, etc. y Various reports. y Ethernet function. y Optional wireless Ethernet card. y RS232C interface for data communicate and barcode scanner connection. y Optional cash drawer. y Compact housing. 9 SM 110 GENERAL 1.6 Specification 1.6.1 Display 25 digits × 19 segment TN type LCD with back-light for numeric digit and character display. y Tare weight display : 4 digits. y Weight display : 5 digits. y Unit price display : 6 digits. y Total price display : 7 digits. 32 x 202 full dot Martix Green LCD display. y Tare weight display : 4 digits. y Weight display : 5 digits. y Unit price display : 6 digits. y Total price display : 7 digits. 1.6.2 Operating Conditions z Power Source : AC 176V ~ 264V, 47~63Hz. z Operating Temperature : -10 °C ~ +40 °C. z Operating Humidity : 15% ~ 85% RH. z Power Consumption : 0.15A. 1.6.3 Dimensions z Platter size 359(W) x 277(D) mm. z Overall size a) Bench : 383.4(W) x 389.3(D) x 162(H) mm. b) Pole : 383.4(W) x 419.3(D) x 552.6(H) mm. 10 SM 110 GENERAL 1.7 Label Type Note: Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the use of varnish labels. Label Type T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 S A B C F1 – F99 Dimension (mm) 28 X 56 31 X 56 34 X 56 40 X 56 43 X 56 46 X 56 49 X 56 55 X 56 37 X 56 40 X 56 43 X 56 49 X 56 28 X 37 46 X 37 46 X 37 62 X 37 Free Format 11 SM 110 INITIAL SETUP 2. INITIAL SETUP 2.1 Setup ¾ Indication of Assemble (1) Use 4 screws to fix the Pole. (1) Use 1 flat screws to fix the Pole. 12 SM 110 INITIAL SETUP ¾ Bubble Adjustment Bubble Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above. 13 SM 110 INITIAL SETUP 2.2 Location of Switches and Connectors Ethernet Port RS232 Port Cash Drawer Port Fuse Holder Power Switch 2.3 Mode Change DISPLAY OPERATION PT kg $/kg $ 0.000 0.000 0.00 0.00 [MODE],[MODE] REMARK Weight mode.Lamp R turns on. XMODE (within 3 seconds) Enter X mode.Lamp X turns on. [MODE] S1 → PLU FILE Enter S mode.Lamp S turns on. [MODE] Z1.0 RESET SALES DAILY Enter Z mode.Lamp Z turns on. PWD X 0 SET Enter Password Set mode.Lamp X flicker 0.000 0.00 0.00 Back to Weight mode.Lamp R turns on. [MODE] [MODE] 0.000 2.4 Memory Initialization To clear all memory. DISPLAY OPERATION PT kg $/kg $ Z1.0 RESET SALES DAILY REMARK Z mode. Lamp Z turns on. DISPLAY OPERATION PT kg $/kg $ 14 REMARK SM 110 INITIAL SETUP [Rezero]+[2][3][0] CLEAR PLU FILE [》] CLEAR VENDER DATA Vender transaction data. [》] CLEAR REPORT FILES Report files. [》] CLEAR MEMORY DATA All files in memory. [*] CLEAR MEMORY Y-C N-T [C] to clear file data,[T] to quit. RESET SALES DAILY Return to Z mode. [C] or [T] Z1.0 PLU file. 2.5 Specification Setting Before setting 141, please enter Z mode. DISPLAY OPERATION PT kg $/kg $ Z1.0 RESET SALES DAILY XXX XXX (setting) (former) [Rezero]+[1][4][1] SPEC 000 REMARK Z mode. Lamp Z turns on. Enter [1][4][1] while depressing [Rezero]. XXX:SPEC data [》]key only increase specification [》] SPEC 001 XXX XXX count, it does not update SPEC data. [《]key only decrease specification [《] SPEC 000 XXX XXX count, it does not update SPEC data. [1][7] SPEC 000 017 XXX [X] SPEC 017 XXX XXX [>>] SPEC 017 XXX XXX [<<] SPEC 017 XXX XXX [1] SPEC 017 001 XXX [*] SPEC 018 XXX XXX [C] SPEC 018 000 XXX RESET SALES DAILY [PLU] * Note 1 Z1.0 Note: Please see Appendix A for the detail specification list 15 It goes to a designed specification count. (000~441 is enabled) [>>] key select SPEC data. Move cursor right. [<<] key select SPEC data. Move cursor left. Clear the enter data. Store the updated specification and escape to Z mode. SM 110 INITIAL SETUP 2.6 Password Setting 2.6.1 Procedures of Password Setting DISPLAY OPERATION PT kg $/kg $ Z1.0 RESET SALES DAILY REMARK Z mode. Lamp Z turns on. Display password for X mode . XXXX: former password [MODE] PWD X XXXX SET 0: Not set (1~4 bits are enable)Lamp X flicker. Set password for X mode as 1234. [1][2][3][4] PWD X 1234 SET Press [*] to save password for X [*] PWD S XXXX SET mode. Lamp S flicker. [*] PWD Z XXXX SET [3][3] PWD Z 33 SET [C] PWD Z 0 SET [*] PWD P XXXX SET Display password for Z mode. Lamp Z flicker. Clear the password for Z mode. Display password for PWD mode. Lamp R X S Z flicker. Set password for PWD mode as [1][1][1][1] PWD P 1111 SET 1111. Lamp R X S Z flicker. [*] 0.000 0.000 0.00 0.00 Return R mode after password setting. 2.6.2 Password Using {Hypothesis: PWD X: 1111; PWD S: No Set; PWD P: 1234} DISPLAY OPERATION [MODE],[MODE] (within 3 seconds) OPERATION PT kg $/kg $ 0.000 0.000 0.00 0.00 ENTER PWD X DISPLAY 16 REMARK Weight mode. Lamp R turns on. Need X mode password. Lamp X turns on. REMARK SM 110 INITIAL SETUP kg $/kg $ [1][2][3][4] ENTER PWD X **** [*] ENTER PWD X [1][1][1][1] ENTER PWD X **** X1.0 READ SALES DAILY S1 → PLU FILE PT [*] [MODE] Incorrect password. Retry. Correct password. Enters X mode. Enters S mode. Lamp S turns on. Need Z mode password. [MODE] ENTER PWD Z [3][3] ENTER PWD Z ** RESET SALES DAILY [MODE] ENTER PWD P [1][2][3][4] ENTER PWD P **** Correct password. [*] PWD X 1111 SET Enters PWD mode. 0.000 0.00 0.00 [*] Z1.0 [MODE] 0.000 Lamp Z turns on. Correct password. Enters Z mode. Need PWD mode password. Back to Weight mode. Lamp R turns on. 2.7 Clear Files This function is used to clear files in Memory. DISPLAY OPERATION REMARK PT kg $/kg $ Z1.0 RESET SALES DAILY [Rezero]+[2][3][0] CLEAR PLU FILE [》] CLEAR VENDER DATA Vender transaction data. [》] CLEAR REPORT FILES Report files. [》] CLEAR MEMORY DATA All files in memory. [*] CLEAR MEMORY Y-C N-T [C] to clear file data,[T] to quit. RESET SALES DAILY Return to Z mode. [C] or [T] Z1.0 17 Z mode. Lamp Z turns on. PLU file. SM 110 PROGRAM MODE 3. PROGRAM MODE 3.1 Programmable Files In Programming Mode, there are two ways to select the Programming File by using different keys such as: • Enter the Number key. • Press [《] key or [》] key to select the Data File. The files listed below can be programmed in PROGRAM Mode (S Mode). Key To Press Data files Key To Press Data files [1] PLU Programming [1] [7] Logo Programming [2] Department Programming [1] [8] Tax Programming [3] Main Group Programming [1] [9] Program or Skip Item Data [4] Key Assignment [2] [0] Memory Status [5] Shop Name Programming [2] [1] I/F Test [6] Advertisement Programming [2] [2] File Load [7] Vender Programming [8] Date and Time Programming [9] Special Message Programming [1] [0] Ingredients Programming [1] [1] Text Programming [1] [2] Free Format Programming [1] [3] Scrolling Message Programming [1] [4] Scroll Sequence Programming [1] [5] Place Programming [1] [6] Machine setting 18 SM 110 PROGRAM MODE 3.2 General Explanation DEPARTMENT, MAIN GROUP and PLU files are connected as shown below. By the following linking method, more detail and concrete information on sales transaction or pre-pack data can be got by printing various reports. DEPARTMENT FILE DEPARTMENT file is the largest category whose items are like MEAT, FISH, VEGETABLE or DELICATESSEN etc. MAIN GROUP FILE MAIN GROUP file is the middle category including items such as BEEF, PORK, CHICKEN, etc. You can link a Main Group to a Department in the Main Group file. Tax Number can be assigned to a Main Group. The assigned Tax Number will apply for all the PLU’s assigned to the Main Group. PLU FILE PLU File is the smallest category including items such as BEEF SLICE, BEEF SHOULDER and BEEF SIRLOIN. You can link the PLU to a Main Group in the PLU programming file. C onnection o f DEPA RT M E NT, M AIN G RO U P and P LU : SHO P D EPT. M .G . P LU PLU M .G. PLU Departm ent File D EPT. P LU M .G. PLU PLU 19 M ain G roup File M .G . P LU PLU PLU File SM 110 PROGRAM MODE 3.3 Department Files Department file is used for categorizing Main Groups. Department Number between 1 ~ 99 are available for programming. The Main Groups that are not linked to any Department will be assigned to Department Number 97 automatically. Maximum 16 characters per file are available and each with 1 line. 3.3.1 Program Department File OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S2 → DEPT FILE [*] S2.0 DEPT 0 NO SET [1] S2.0 DEPT 1 NO SET [*] S2.1 DEPT [MODE][MODE] [MODE] [2] or [X]、[》] NAME 0 REMARK Enter S mode. Lamp S turns on. Select Department Programming. $ /kg window displays DEPT. code. Enter department No.(Ex. [1]) Enter department programming, set the department name. Enter DEPT. name(use letter keys)(Ex. “MEAT” for Dept. No [M][E][A][T] S2.1 DEPT MEAT NAME 4 1) The methods of ASII letter input refer to 3.23 ASSII Character Input Method. [PLU] S2 → DEPT FILE Store the department file, back to S mode. Note1: Number after "NAME" in Total display shows the position of the cursor. Note2: The DEPT. No.1 to No.99 are available for programming. (No.97 is default No. for PLU programming, and the PLUs which are not linked to any DEPT No. are assigned to No.97) (Non-PLU files (Weighing items) are assigned to DEPT code No.98) (Non-PLU files (Non-weighing items) are assigned to DEPT code No.99) Note3: The Department names programmed are not printed on the label/receipt but are for reporting. 20 SM 110 PROGRAM MODE 3.3.2 Delete Department File OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S2 → DEPT FILE [*] S2.0 DEPT 0 NO SET [1] S2.0 DEPT 1 NO SET [-] S2.0 DEPT DEL ? Y-C N-T [C] S2 → DEPT FILE [MODE][MODE] [MODE] [2] or [》] REMARK Enter S mode. Lamp S turns on. Select Department Programming. $ /kg window indicates DEPT. code. Enter department No.(Ex. [1]) Delete Dept. No.1 for “MEAT”. [C] for Yes, [T] for No. Delete the Dept. file 1, back to S mode. Note1: When the MAIN GROUP FILE exists under the Department File, the Department Number cannot be deleted. In addition, the Department Number 97, 98 and 99 cannot be deleted. 21 SM 110 PROGRAM MODE 3.4 Main Group Files Main Group is the middle category and can be assigned to a Department. The Main Group file is used for categorizing the PLU's. Main Group Number of 1 ~ 999 are available for programming. PLU's that are not linked to any Main Group Number will be assigned to the Main Group Number 997 automatically. TAX is assigned to every Main Group. The assigned TAX will apply for all the PLU's assigned to the Main Group. Up to 250 data can be programmed in Main Group file. Maximum 16 characters per file are available and each with 1 line. 3.4.1 Program Main Group File OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S3 → MGROUP FILE [*] S3.0 MG 0 NO SET [1][1][1] S3.0 MG 111 NO SET [*] S3.1 MG [1] S3.1 MG [*] S3.2 MG [B][E][E][F] S3.2 MG BEEF NAME 4 [*] S3.3 MG 0 TAX NO [1] S3.3 MG 1 TAX NO [MODE][MODE] [MODE] [3] or [》] 97 (default) 1 DEPT NO DEPT NO NAME 0 REMARK Enter S mode. Lamp S turns on. Select Main Group Programming. $ /kg window indicates Main Group code. Select Main Group No. (Ex. [1][1][1]) Enter Main Group programming, Set the Department number. Link Main Group 111 to Department 1. Name of the Main Group 111 is “BEEF’. Set the Tax number. Tax of Main Group 111 is tax number 1. Store the Main Group file, back to S [PLU] S3 → MGROUP FILE mode. If you want to exit without saving data, press [◇] key and then follow by [C] key Note1: For tax rate programming, refer to 3.20 Tax File in S Mode. if not necessary to link the Tax Number, press [*] key to enter next selection. This procedure will skip if SPEC 603 is set to "NO TAX". Note2: Number after "NAME" in Total display shows the position of the cursor. Note3: The Main Group No.1 to No.997 are available for PLU programming. 22 SM 110 PROGRAM MODE (No.997 is default No. for PLU programming, and the PLUs which are not linked to any Main Group No. are assigned to No.997) (Non-PLU files (Weighing items) are assigned to Main Group code No.998) (Non-PLU files (Non-weighing items) are assigned to Main Group code No.999) Note4: The Main Group names programmed are not printed on the label/receipt but are for reporting. Note5: Each Main Group No. must be linked to the exiting Dept. No.(Refer to 3.3 Department File). 3.4.2 Delete Main Group File OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S3 → MGROUP FILE [*] S3.0 MG 0 NO SET [1][1][1] S3.0 MG 111 NO SET [-] S3.0 MG DEL ? Y-C N-T [C] S3 → MGROUP FILE [MODE][MODE] [MODE] [3] or [》] REMARK Enter S mode. Lamp S turns on. Select Main Group Programming and Enter it. Enter Main Group No. (Ex. [1][1][1]) [C] for Yes, [T] for No. Delete M.G. file 111,back to S mode. Note1: When the PLU FILE exists under the Main Group File, the Main Group Number cannot be deleted. In addition, the Main Group Number 997, 998 and 999 cannot be deleted. 23 SM 110 PROGRAM MODE 3.5 Program / Skip Item Data Unnecessary PLU parameters will be skipped automatically due to auto-skip function, it is possible to set only necessary PLU parameter in PLU programming procedure "Program PLU File". The following parameters are available for Program/ Skip function Display No. Parameter Symbol 1 [LABFR1] 1. Label format 1 LABFR1 2 [LABFR2] 2. Label format 2 LABFR2 3 [BACODE] 3. Barcode Selection BACODE 4 [FLAG] 4. Barcode Flag data FLAG 5 [ITCODE] 5. Barcode Item Code ITCODE 6 [MGCODE] 6. Main Group Code MGCODE 7 [SELLDT] 7. Sell by Date SELLDT 8 [SELLTM] 8. Sell by Time SELLTM 9 [USEDDT] 9. Used by Date USEDDT 10 [PACKDT] 10. Packed Date PACKDT 11 [PACKTM] 11. Packed Time PACKTM 12 [COST] 12. Cost COST 13 [TARE] 13. Tare TARE 14 [QTY] 14. Quantity QTY 15 [Q.UNIT] 15. Quantity Unit QUNIT 16 [DISCNT] 16. Discount Status DISCNT 17 [SCH DT] 17. Discount Schedule date SCHDT 18 [SCH TM] 18. Discount Schedule time SCHTM 19 [MARKDN] 19. Mark Down Status MARKDN 20 [1STLMT] 20. 1st target for discount 1 FSTLMT 21 [2NDLMT] 21. 2nd target for discount 2 SNDLMT 22 [SMGNUM] 22. Special Message # SMGNUM 23 [INGNUM] 23. Ingredients # INGNUM 24 [COMNAM] 24. Commodity Name COMNAM 25 [SP 25. Special Message SPMG 26 [INGR] 26. Ingredients INGR 27 [PLCNUM] 27. Place of Production PLCNUM 28 [IMAGE] 28. Image IMAGE 29 [BONUS] 29. Bonus BONUS 30 [NUTRI] 30. Nutrition NUTRI 31 [ITFSEL] 31. ITF Selection ITFSEL 32 [REFPLU] 32. Reference PLU No. REFPLU 33 [SECPLU] 33. Security PLU SECPLU 34 [COUPLU] 34. Coupled PLU COUPLU MG] 24 SM 110 PROGRAM MODE Display No. Parameter Symbol 35 [DAY WK] 35. Discount day of the week DAYWK 36 [ADD-ON] 36. EAN 5 Digit ADD-ON ADDON 37 [TAX] 37. TAX No. TAX 38 [PRICE2] 38. 2nd Price PRICE2 39 [% 39. Proportional Tare PROTARE 40 [CUSDIS] 40. Customer Discount CUSDIS 41 [RESDIS] 41. Restaurant Discount RESDIS 42 [STADIS] 42. Staff Discount STADIS 43 [TRACE] 43. Traceability Discount TRACE 44 [TEMP] 44. Storage Temperature TEMP 45 [PACK.I] 45. Pack. Indicator PACKI 46 [M1BARC] 46. Multi Barcode 1 M1BARC 47 [M2BARC] 47. Multi Barcode 2 M2BARC 48 [TM1BAR] 48. Total Multi Barcode 1 TM1BAR 49 [TM2BAR] 49. Total Multi Barcode 2 TM2BAR 50 [U.PRIC] 50. Unit Price Selection UPRIC 51 [PLUSCR] 51. PLU Scroll (U1 only) PLUSCR 52 [PLUTEX] 52. PLU Linked Text Field PLUTEX TARE] Program/Skip Item Data OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S19 → PLU ITEM [*] S19.1 ITEM [*][*][*][*][*] S19.1 ITEM [X] S19.1 S19 [MODE][MODE] [MODE] [1][9] or [》] [PLU] REMARK Enter S mode. Lamp S turns on. Select PLU item Selection Mode and enter PROGRAM Enter Program or Skip parameter selection mode. MGCODE SKIP Select parameter of Main Group. ITEM MGCODE PROGRAM → PLU ITEM LABFR1 Select PROGRAM for the parameter of Main Group. After finish setting, save it. Back to S mode. Note1: Press [*] key to next parameter or [−] key to previous parameter and press [X] key to select PROGRAM or SKIP for each parameter, if necessary. Note2: If you want to exit without saving, press [◇] key follow by [C] key. 25 SM 110 PROGRAM MODE 3.6 PLU Programming The following items can be programmed in PLU PROGRAMMING mode. The format chosen for the PLU will decide what items can be programmed in the PLU file. The items which print areas are not set on the selected format will skip automatically or not printed on label. (If the item doesn't appear on the PLU programming, check whether the parameter is set to ENABLE in Program / Skip Item Data). PLU file for weighing item and non-weighing item listed below can be programmed according to the following order. Weighing Item Step PLU File (weighing Item) Remarks S1.0 PLU No. S1.1 Unit Price (6 digits) S1.2 Label Format for the 1st label Refer to Label Format List. S1.3 Label Format for the 2nd label Free format No.1~99 only. S1.4 Commodity Name Font Size S1.4 Commodity Name S1.5 Selection of ITF Barcode Format S1.6 Bar Code Selection S1.7 Flag data S1.8 Item Code No. * Digits of Flag and Item data can be selected in the barcode type selection in S1.6. S1.9 Item Code No. (Lower 4 digits) Only when Item Code is more than 6 digits. S1.10 Right Side Data of Item Barcode Only when Spec02 set to 3. S1.11 Selection of EAN ADD-ON S1.12 Main Group No. S1.13 Select whether to print Sell by date S1.14 Sell by date (Days after the current date) S1.15 Select whether to print Sell by time S1.16 Select key-in data or present time S1.17 Sell by Time (If Key-In is selected) S1.18 Select whether to print Used by date S1.19 Used by date (days after Packed date) S1.20 Select whether to print Packed date S1.21 Packed Date (days after actual packed date) S1.22 Select whether to print Packed time * If No Print is selected, Sell- by Date in S1.12 is skipped. * If No Print is selected, Key in selection in S1.14 Sell-by time in S1.15 is skipped. * If S1.14 select CLOCK TIME, Key in selection in S1.15 is skipped. * If No Print is selected, Used- by Date in S1.17 is skipped. * If No Print is selected, Packed Date in S1.19 is skipped. * If No Print is selected, Key-in selection in S1.21 Packed time in S1.22 are skipped. 26 SM 110 Step PROGRAM MODE PLU File (weighing Item) Remarks S1.23 Select to print Key-In data or actual time S1.24 Packed Time (if key-In is selected) S1.25 Cost price S1.26 PLU Tare * Depends on SPEC: 647 SETTING. S1.29 Type of Volume Discount * Depends on SPEC: 100 SETTING. S1.30 The 1st target of volume discount S1.31 The discount value for the 1st target S1.32 The 2nd target of volume discount S1.33 The discount value for the 2nd target S1.34 Print type of Discount price (Mark Down) S1.35 Schedule of Volume Discount (The start date) S1.36 Schedule of Volume Discount (The start time) S1.37 Schedule of Volume Discount (The end date) S1.38 Schedule of Volume Discount (The end time) S1.39 S1.41 Selection of Discount Day of The Week. Special message No. (Select No. from SP message file) Ingredient No. (Select No. from Ingredient file) S1.42 Special message (Program original Special Message) S1.43 Ingredient (Program original Ingredient) S1.44 Place of production (Select No. from Place file) S1.45 Coupled PLU Number S1.46 TAX Number (Select Number from TAX File) S1.47 Reference PLU Number S1.48 Proportional Tare S1.40 * If S1.21 select CLOCK TIME, Key in selection in S1.22 is skipped. * If No Volume discount is selected, the parameters in S1.27 ~ S1.36 are skipped. *Entering by Number keys (0~3) * If selected Label Format without PRINT AREA, S1.40 ~ S1.43 are skipped. * If selected Label Format without PRINT AREA, the PLACE message will print on 1st line of Commodity Name. *Depend on SPEC: 603 SETTING. *Depend on SPEC: 687 SETTING. 27 SM 110 PROGRAM MODE Non-Weighing Item Step PLU File (Non-weighing Item) Remarks S1.0 PLU No. S1.1 Unit Price (6 digits) S1.2 Label Format for the 1st label Refer to Label Format List. S1.3 Label Format for the 2nd label Free format No.1~99 only. S1.4 Commodity Name Font Size S1.4 Commodity Name S1.5 Selection of ITF Barcode Format S1.6 Bar Code Selection S1.7 Flag data S1.8 Item Code No. * Digits of Flag and Item data can be selected in the barcode type selection in S1.6. S1.9 Item Code No. (Lower 4 digits) Only when Item Code is more than 6 digits. S1.10 Right Side Data of Item Barcode Only when Spec02 set to 3. S1.11 Selection of EAN ADD-ON S1.12 Main Group No. S1.13 Select whether to print Sell by date S1.14 Sell by date (Days after the current date) S1.15 Select whether to print Sell by time S1.16 Select key-in data or present time S1.17 Sell by Time (If Key-In is selected) S1.18 Select whether to print Used by date S1.19 Used by date (days after Packed date) S1.20 Select whether to print Packed date S1.21 Packed Date (days after actual packed date) S1.22 Select whether to print Packed time S1.23 Select to print Key-In data or actual time S1.24 Packed Time (if key-In is selected) S1.25 Cost price S1.27 Unit Symbol (PCS / FOR / kg / lb / g / NO SYMBOL) S1.28 Quantity S1.29 Type of Volume Discount * If No Print is selected, Sell- by Date in S1.12 is skipped. * If No Print is selected, Key in selection in S1.14 Sell-by time in S1.15 is skipped. * If S1.14 select CLOCK TIME, Key in selection in S1.15 is skipped. * If No Print is selected, Used- by Date in S1.17 is skipped. * If No Print is selected, Packed Date in S1.19 is skipped. * If No Print is selected, Key-in selection in S1.21 Packed time in S1.22 are skipped. * If S1.21 select CLOCK TIME, Key in selection in S1.22 is skipped. * Depends on SPEC: 100 SETTING. 28 SM 110 PROGRAM MODE Step PLU File (Non-weighing Item) 1st Remarks S1.30 The target of volume discount S1.31 The discount value for the 1st target S1.32 The 2nd target of volume discount S1.33 The discount value for the 2nd target S1.34 Print type of Discount price (Mark Down) S1.35 Schedule of Volume Discount (The start date) S1.36 Schedule of Volume Discount (The start time) S1.37 Schedule of Volume Discount (The end date) S1.38 Schedule of Volume Discount (The end time) S1.39 Selection of Discount Day of The Week. S1.40 Special message No. (Select No. from SP message file) S1.41 Ingredient No. (Select No. from Ingredient file) S1.42 Special message (Program original Special Message) S1.43 Ingredient (Program original Ingredient) S1.44 Place of production (Select No. from Place file) S1.45 Coupled PLU Number S1.46 TAX Number (Select Number from TAX File) S1.47 Reference PLU Number * If No Volume discount is selected, the parameters in S1.27 ~ S1.36 are skipped. *Entering by Number keys (0~3) * If selected Label Format without PRINT AREA, S1.40 ~ S1.43 are skipped. * If selected Label Format without PRINT AREA, the PLACE message will print on 1st line of Commodity Name. *Depend on SPEC: 603 SETTING. 29 SM 110 PROGRAM MODE 3.6.1 Program PLU File(weighing item) PLU data(weighing item) is programmed by following procedure as below. If the selected 1st or 2nd label format does not have print area for the PLU items, the item will be skipped automatically or not printed on label. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE [*] S1.0 PLU 0 NO SET [1][0][0] S1.0 PLU 100 NO SET [*] S1.1 PLU 0.00 PR-KG [MODE][MODE] [MODE] REMARK Enter S mode. Lamp S turns on. Enter PLU programming mode. $/kg window displays PLU number. Enter new PLU Number (Ex. 100) you want. Enter PLU programming. Enter unit price.(Ex.5.80$/kg) Select Label format for 1st Label by press [<<] [5][8][0][*] S1.2 PLU DFT 0 LAB FR1 or [>>] key. (T1~T12,S,A,B,C,F1~F8 is available) [<<] or [>>] S1.2 PLU T6 6 LAB FR1 Set the Label format (Ex.T6) by press [6] or[>>] key. Select Label format for 2nd Label by press [<<] [*] S1.3 PLU NO 0 LAB FR2 or [>>]key. (F1~F8 only) [<<] or [>>] S1.4 C01.01 S1 A 100 Enter commodity name.(Ex. “SLICE”) S1.4 C02.01 S1 A 100 Enter the 2nd line of commodity name. [*] S1.5 PLU EAN BARCODE [*] S1.6 PLU DFLT BARCODE [*] [S][L][I][C][E] [*] Select the type of BARCODE by press [X] or [>>].(EAN or ITF) Select barcode format by press [<<] or [>>] key.(Ex.2f5c4i4wD) Set flag data.(Ex.29) [<<] or [>>] [*] S1.7 PLU 20 FLAG The Default Flag Data can be set at SPEC 3 ~ 6 and the Flag data consists of one or two digits, which depends on the selected Barcode type. [2][9] [*] S1.8 PLU 00000 IT CODE 30 Enter item code.(Ex.10010) SM 110 OPERATION [1][0][0][1][0] [*] [*] PROGRAM MODE DISPLAY PT kg $/kg $ S1.9 PLU 00000 EX CODE S1.10 PLU EAN REMARK No appended item code of PLU 100. ADD Select EAN ADD-ON or EAN ADD-OFF.(Ex. OFF EAN ADD-OFF) Set the Main Group number.(default MG 997) [*] S1.12 PLU 997 MG NO Enter Main Group No.(Ex.111) Link PLU 100 to Main Group 111. [1][1][1] [*] [<<] or [>>] [*] [3] [*] Press [<<] or [>>] key to change whether print S1.13 PLU NPRINT SELL DT sell-by-date. (Ex. Print sell by date) S1.14 PLU 0 SELL DT Set sell-by-date.(Ex.3 days) 3 digits can be set.(0~999) Press [<<] or [>>] key to change whether print S1.15 PLU NPRINT SELL TM sell-by-time. (Ex. No print sell by time) Press [<<] or [>>] key to change whether print [*] S1.18 PLU NPRINT USED DT used by date. (Ex. No print used by date) Set used-by-date, used-by-time [*] [<<] or [>>] [*] [1][*] [<<] or [>>] [*] [<<] or [>>] [*] [1][8][0][0] [*] [*] … … … … S1.20 PLU NPRINT PACK DT Setting way of used-by-date, used-by-time are same as setting sell-by-date and sell-by-time. Press [<<] or [>>] key to change whether print packed date. If necessarily, packed date can set the day after S1.21 PLU 0 PACK DT present date. (Ex. 1 day after present day) S1.22 PLU NPRINT PACK TM S1.23 PLU TIME PRESENT S1.24 PLU 0000 PACK TM S1.25 PLU 0.00 COST S1.26 PLU 0.000 TARE 31 Press [<<] or [>>] key to change whether print packed time. Press [<<] or [>>] key to change key-in time or present time. Set the packed time. (Ex. 18:00) Enter Preset Tare of PLU 10.(Ex.0.100kg) SM 110 OPERATION [1][0][0] [*] [*] [1][0][0] [*] [3][0] [*] [1][0][0][0] [*] [5][0] [<<] or [>>] [*] [1][0][0][1][0][4] [*] [0][9][0][0] [*] [1][1][0][1][0][4] [*] [0][9][0][0] [1] [PLU] PT kg $/kg REMARK $ 6 kinds discount type can be selected by press S1.29 PLU NO DISCONT [<<] or [>>] key. S1.30 PLU 0.000 1ST LMT Set 1st limit weight is 0.1kg.(Ex.0.100kg) S1.31 PLU 0.00 1ST AMT Set 1st amount of discount is $0.30. S1.32 PLU 99.999 2ND LMT Set 2nd limit weight is 1.000kg. S1.33 PLU 0.00 2ND AMT Set 2nd amount of discount is $0.50. S1.34 [*] [1][*] DISPLAY (Ex. UNIT PRICE discount) [<<] or [>>] [*] PROGRAM MODE PLU NO MARK DOWN Change selection by [<<] or [>>]: No mark down/Unit price mark down /Total price mark down/all mark down Set discount start day.(Ex.10-01-04, S1.35 PLU 000000 ST DATE S1.36 PLU 0000 ST TIME Set discount start time.(Ex. 09:00, HH-MM) S1.37 PLU 000000 ED DATE Set S1.38 PLU 0000 ED TIME Set discount end time.(Ex. 09:00) S1.40 PLU 0 SMG NUM S1.41 PLU 0 ING NUM S1 → PLU ITEM MM-DD-YY) discount end date.(Ex.11-01-04) Set special message file number.(Ex. Number 1) Special message file 1 is linked to this PLU. Set ingredients file number.(Ex. Number 1) Ingredients file 1 is linked to this PLU. After finish setting, save it. Back to S mode. Note1: Press [*] key to next parameter or [−] key to previous parameter. Note2: The letter before "A" in Total Price display shows the letter font size of the commodity name, and the number after "A" in Total Price display shows the number of letters can be programmed for commodity name. 32 SM 110 PROGRAM MODE Note3: The 2 digits after "C" in Weight display shows the line of the commodity name, and the next 2 digits in Weight display shows the position of the cursor. Note4: The PLU No.1 to No.999999 are available for PLU programming. Note5: The programmed PLU commodity name are printed on the label or receipt. Note6: Max.100 letters for commodity name per file are available. Note7: Each PLU No. must be linked to the exiting Main Group No.(Refer to 3.4 Main Group File). 3.6.2 Program PLU File(non-weighing item) PLU data(non-weighing item) is programmed by following procedure as below. *If the selected 1st or 2nd label format does not have print area for the PLU items, the item will be skipped automatically or not printed on label OPERATION [MODE][MODE] [MODE] DISPLAY PT kg $/kg $ S1 → PLU FILE REMARK Enter S mode. Lamp S turns on. Enter PLU programming mode. [*] S1.0 PLU 0 NO SET $ /kg window displays PLU number. [2][0][0] S1.0 PLU 200 NO SET [*] S1.1 PLU 0.00 PR-KG S1.1 PLU 5.80 PR-PCS [<<] or [>>] [5][8][0] Enter new PLU Number (Ex. 200) you want. Enter PLU programming. Enter unit price.(Ex.5.80$/kg) Change Unit price of PLU 200 to non-weighing item. Select Label format for 1st Label by [*] S1.2 PLU DFT 0 LAB FR1 press [<<] or [>>] key. (T1~T12,S,A,B,C,F1~F8 is available) [<<] or [>>] S1.2 PLU T6 6 LAB FR1 Set the Label format (Ex.T6) by press [6] or[>>] key. Select Label format for 2nd Label [*] S1.3 PLU NO 0 LAB FR2 by press [<<] or [>>]key. (F1~F8 only) [<<] or [>>] [*] S1.4 C01.01 S1 A 100 33 Enter commodity “CAKE”) name.(Ex. SM 110 OPERATION PROGRAM MODE DISPLAY REMARK PT kg S1.4 C02.01 [*] S1.5 PLU EAN BARCODE [*] S1.6 PLU DFLT BARCODE [C][A][K][E] [*] $/kg $ S1 A 100 Enter the 2nd line of commٛ ddity name. Select the type of BARCODE by press [X] or [>>].(EAN or ITF) Select barcode format by press [<<] or [>>] key.(Ex.2f5c4i4wD) Set flag data.(Ex.29) The Default Flag Data can be set at [<<] or [>>] [*] S1.7 PLU 20 FLAG SPEC 3 ~ 6 and the Flag data consists of one or two digits, which depends on the selected Barcode type. [2][9] [*] [2][0][0][2][0] [*] [*] S1.8 PLU 00000 IT CODE S1.9 PLU 00000 EX CODE S1.10 PLU EAN ADD OFF Enter item code.(Ex.20020) No appended item code of PLU 100. Select EAN ADD-ON or EAN ADD-OFF.(Ex. EAN ADD-OFF) Set [*] S1.12 PLU 997 MG NO the Main Group number.(default MG 997) Enter Main Group No.(Ex.222) Link PLU 200 to Main Group 222. [2][2][2] [*] [<<] or [>>] [*] [3] [*] [*] Set used-by-date, used-by-time Press [<<] or [>>] key to change S1.13 PLU NPRINT SELL DT whether print sell-by-date. (Ex. Print sell by date) S1.14 PLU 0 SELL DT Set sell-by-date.(Ex.3 days) 3 digits can be set.(0~999) Press [<<] or [>>] key to change S1.15 PLU NPRINT SELL TM whether print sell-by-time. (Ex. No print sell by time) S1.18 PLU NPRINT USED DT Press [<<] or [>>] key to change whether print used by date. Setting … … … … way of used-by-date, used-by-time are same as setting sell-by-date and sell-by-time. 34 SM 110 OPERATION [*] [<<] or [>>] [*] [1][*] [<<] or [>>] [*] [<<] or [>>] [*] [1][8][0][0] [*] PROGRAM MODE DISPLAY PT kg $/kg $ S1.20 PLU NPRINT PACK DT REMARK Press [<<] or [>>] key to change whether print packed date. If necessarily, packed date can set S1.21 PLU 0 PACK DT the day after present date. (Ex. 1 day after present day) S1.22 PLU NPRINT PACK TM S1.23 PLU TIME PRESENT S1.24 PLU 0000 PACK TM S1.25 PLU 0.00 COST Press [<<] or [>>] key to change whether print packed time. Press [<<] or [>>] key to change key-in time or present time. Set the packed time. (Ex. 18:00) Press [<<] or [>>] to select unit [*] S1.27 PLU PCS USYMBOL symbol. Selection: PCS/FOR/kg/lb/g/NO [<<] or [>>] [*] [1][0] [*] S1.28 PLU 0 QTY 4 digits can be set.(0~9999). (Ex. 10 pcs/PLU) 6 kinds discount type can be S1.29 PLU NO DISCONT selected by press [<<] or [>>] key. (Ex. UNIT PRICE discount) Change selection by [<<] or [>>]: [<<] or [>>] [*] No mark down/Unit price mark S1.34 PLU NO MARK DOWN down /Total price mark down/all mark down [<<] or [>>] [*] [1][0][0][1][0][4] [*] [0][9][0][0] [*] S1.35 PLU 000000 ST DATE S1.36 PLU 0000 ST TIME S1.37 PLU 000000 ED DATE 35 Set discount start day.(Ex.10-01-04, MM-DD-YY) Set discount start time.(Ex. 09:00, HH-MM) Set discount date.(Ex.11-01-04) end SM 110 OPERATION [1][1][0][1][0][4] [*] PROGRAM MODE DISPLAY PT kg $/kg $ S1.38 PLU 0000 ED TIME REMARK Set discount end time.(Ex. 09:00) Set [0][9][0][0] [*] S1.40 PLU 0 SMG NUM special message file number.(Ex. Number 1) Special message file 1 is linked to this PLU. Set ingredients file number.(Ex. [1][*] S1.41 PLU 0 ING NUM Number 1) Ingredients file 1 is linked to this PLU. [1] [PLU] S1 → PLU ITEM After finish setting, save it. Back to S mode. Note1: Press [*] key to next parameter or [−] key to previous parameter. Note2: The letter before "A" in Total Price display shows the letter font size of the commodity name, and the number after "A" in Total Price display shows the number of letters can be programmed for commodity name. Note3: The 2 digits after "C" in Weight display shows the line of the commodity name, and the next 2 digits in Weight display shows the position of the cursor. Note4: The PLU No.1 to No.999999 are available for PLU programming. Note5: The programmed PLU commodity name are printed on the label or receipt. Note6: Max.100 letters for commodity name per file are available. Note7: Each PLU No. must be linked to the exiting Main Group No.(Refer to 3.4 Main Group File). 36 SM 110 PROGRAM MODE 3.6.3 PLU [COPY] Function The programmed PLU data can be easily copied into a new PLU. The function is very useful to save time or avoid mistake for the similar PLU data programming, especially in case of long description of Ingredients. Example: PLU No.124 is programmed with most data of the PLU No. 100 already in memory. DISPLAY OPERATION REMARK PT kg $/kg $ S1 → PLU FILE [*] S1.0 PLU 0 NO SET [1][2][4] S1.1 PLU 124 NO SET Select PLU 124,enter PLU programming. [X] S1.1 PLU 0 COPY Press [X] key to enter PLU copy function. S1.1 PLU 5.80 PR-KG Copy PLU 100 data to PLU 124. S1.2 PLU T6 [*] S1.3 PLU NO 0 LAB FR2 [*] S1.4 C01.01 SLICE S1 A 95 S1.8 PLU 10100 IT CODE [1][0][1][2][4] S1.8 PLU 10124 IT CODE [*] S1.9 PLU 00000 EX CODE S1 → PLU FILE [MODE][MODE] [MODE] [1][0][0] [*] [4][8][0] [*] Press [*] key times [PLU] 5 6 LAB FR1 37 Enter S mode. Lamp S turns on. Enter PLU programming mode. $/kg window displays PLU number. Unit price of PLU 124 is 4.80$/kg. The 1st Label format is T6. Commodity Name of PLU 124 is “SLICE”. Item code of PLU 124 is 10124. Store the PLU 124 file, back to S mode. SM 110 PROGRAM MODE 3.6.4 Delete PLU File OPERATION [MODE][MODE] [MODE] DISPLAY PT kg $/kg $ S1 → PLU FILE REMARK Enter S mode. Lamp S turns on. Enter PLU programming mode. [*] S1.0 PLU 0 NO SET $ /kg window displays PLU number. [1][2][4] S1.0 PLU 124 NO SET [-] S1.0 PLU DEL ? Y-C N-T [C] S1 → PLU FILE Select PLU 124.(Ex. Delete PLU No.124) Press [-] key to delete PLU 124. [C] for Yes, [T] for No. Delete PLU file No.124, back to S mode. Note1: Only the programmed PLU file can be deleted. Note2: In the last operation, pressing [T] key can back to the S Mode without deleting PLU file 124. 38 SM 110 PROGRAM MODE 3.6.5 Volume Discount & Mark Down print function Volume Discount function is used to set up special price during a sales period. Shop manager may program the discount price during a sales period, and the Shop manager can avoid sales loss caused by not returning the discount price back to the original price even after the sales period. Type of Volume Discount Shop manager can select a discount type from 5 types of volume discount. The formulas of 5 discount type are shown in the following table. Formula of Discount price Discount Type Free Item Formula Example Price = 0 Total Price = 0 (1) Unit Price = Original Unit Price Unit Price discount amount. Original Unit Price = $ 10.00 To called up PLU with 0 Unit Price and allow issuing a receipt or label, SPEC 231 must set to "ALLOW" in advance. Unit Price Discount To select Formula (1) or Formula (2) can be decided by SPEC 124 Setting. Unit Price % Discount (2) Unit Price = Unit Price discount amount. Unit Price discount amount = $2.00 (1) Unit Price = $10.00 - $2.00 = $8.00 (2) Unit Price = $2.00 Unit Price = Original Unit Price x (100% - % Discount) Original Unit Price = $ 10.00 % Discount = 20% Unit Price = $10.00 x (100% - 20%) = $8.00 Total Price Discount Total Price = Original Price - Price Discount Amount Original Total Price = $10.00 Price Discount Amount = $2.00 Total Price = $10.00 - $2.00 = $8.00 Total Price % Discount Total Price = Original Total Price x (100% - % Discount) Original Total Price = $10.00 % Discount = 20% Total Price = $10.00 x (100% - 20%) = $8.00 Fixed Price Discount Total Price = Fixed Price Amount Original Total Price = $10.00 Fixed Price Amount = $8.00 Total Price = $8.00 39 SM 110 PROGRAM MODE Mark Down Print Function (How to print discount price) Mark Down Print function is used to print the discount price as well as the original price with double lines crossed when item is discounted. Mark Down Print function can be selected from the following 4 types, No Mark down / Unit Price Mark down/ Price Mark down / Unit Price & Price Mark down. Type of Sales price function Description of Sales Price data on label Unit Price No Mark Down Unit Price Mark Down Total Price $1.50 $ $15.00 2.00 $15.00 1.50 Total Price Mark Down Unit & Total Price Mark Down $1.50 $ Refer to Note 1 2.00 $ $ 1.50 20.00 15.00 20.00 15.00 Note 1: Since discount unit price cannot be calculated if Total Price discount is used, it is not able to use Unit Price Mark Down function, when using Total Price discount and Free item discount. 40 SM 110 PROGRAM MODE 3.7 Memory Status The function is used for checking the number of existing PLU and remaining programmable PLU. OPERATION [MODE][MODE] [MODE] DISPLAY PT kg $/kg $ S1 → PLU FILE REMARK Enter S mode. Lamp S turns on. Select memory status check mode. [2][0] S20 → MEMORY STATUS You can press [《] or [》] key to select this mode. [*] S20.0 PLU [T] S20 → P 7 MEMORY 41 LF 4544 STATUS Back to S mode. SM 110 PROGRAM MODE 3.8 Key Assignment The Preset keys can be used for assignment of PLUs and Function keys to speed up the operation in R mode. 3.8.1 PLU Assignment PLU Number can be assigned to a preset key to call up PLU data by pressing the assigned preset key on Registration Mode. For example: Assign PLU Number 100 to Preset Key Number 1. OPERATION DISPLAY REMARK PT kg $/kg $ S1 → PLU FILE S4 → KEY ASSIGNMENT [*] S4.0 PS AS 0 NO SET Enter PLU assignment mode. [1][0][0] S4.0 PS AS 100 NO SET Enter PLU No.100 [PRESET 1] S4.0 PS AS 0 NO SET S4 → KEY ASSIGNMENT [MODE][MODE] [MODE] [4] or [》] three times [◇][C] Enter S mode. Lamp S turns on. Key Assignment mode is MENU 4 in S mode. PLU No.100 had been assigned to Preset Key 1. Back to S mode. Note1: Non-existing PLU No. can not be assigned. Note2: If assigning PLU Number 50 to the Preset key No. 1 has been already programmed, the PLU No. 50 will replace the old data of Preset Key No. 1, but PLU Number cannot replace the preset key are already assign for Function Key, Vender Key or Preset Tare. 3.8.2 Function Key Assignment By assigning the following function keys to Preset keys, the functions can be used by touching the assigned keys OPERATION [MODE][MODE] [MODE] [4] or [》] three times [*] DISPLAY PT kg $/kg $ S1 → PLU FILE S4 → KEY ASSIGNMENT S4.0 PS AS 0 NO SET 42 REMARK Enter S mode. Lamp S turns on. Key Assignment mode is MENU 4 in S mode. Enter PLU assignment mode. SM 110 OPERATION PROGRAM MODE DISPLAY PT kg $/kg $ [*] S4.1 VR AS 0 NO SET [*] S4.2 FN AS 0 CLEAR [X][X] S4.0 FN AS 2 -PRICE REMARK Enter Vender Key assignment status. Enter Function Key assignment status. Select PRICE DISCOUNT function PRICE DISCOUNT function had [PRESET 25] S4.2 FN AS 0 CLEAR been assigned to Preset Key number 25. [◇][C] S4 KEY → ASSIGNMENT Back to S mode. Note1: Non assigned Preset Key can be set as function key. 3.8.3 Delete Preset Key Assignment The following operation as below is to delete the Preset Key Assignment for PLU preset key, Function Key and Vender key. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S4 → KEY ASSIGNMENT [*] S4.0 PS AS 0 NO SET [*] S4.2 FN AS 0 CLEAR [PRESET 25] S4.0 FN AS DEL ? Y-C N-T [C] S4.0 FN AS 0 CLEAR S4 → KEY ASSIGNMENT [MODE][MODE] [MODE] [4] or [》] three times [◇][C] REMARK Enter S mode. Lamp S turns on. Key Assignment mode is MENU 4 in S mode. Enter PLU assignment mode. Enter Function Key assignment status. Enter deleting mode. [C] for Yes, [T] for No. Back to S mode. Note1: Non assigned Preset Key can not be cleared. Note2: In the last operation, pressing [T] key can back to Assigned key clear mode and do not clear the assigned key 43 SM 110 PROGRAM MODE 3.9 Shop Name File Shop Name data will be printed on Label or Receipt can be programmed in this file. The maximum number of characters possible to enter varies according to the size of print area or character size entry. Up to 32 Shop Names can be programmed with each 3 lines as maximum and number of line is depends on the Character Size entry. The default Shop Name print on label can be set at SPEC 46 & print centering of shop name on label can be select at SPEC 250 and default Shop Name print on Receipt can be set at SPEC47 & printing position can be select at SPEC251. 3.9.1 Program Shop Name File At Programming Mode, select Shop Name programming mode and then enter new Shop Name number (Ex. 1) programming mode. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S5 → SHOP NAME FILE [*] S5.0 SHOP 0 NO SET [1][*] S5.1 S01.01 [MODE][MODE] [MODE] [5] or [》] four times S1 A 100 REMARK Enter S mode. Lamp S turns on. Shop name File mode is MENU 5 in S mode. Enter Shop Name File programming mode. Enter shop name code.(Ex.No.1) Press [SIZE] key to change font [SIZE][D][I][G][I][SP ][S][H][O][P] S5.1 S01.10 SHOP S2 A 76 size of the shop name. Enter the shop name .(Ex. “DIGI SHOP”) [*] S5.1 S02.01 S1 A 100 [T][E][L][:]…… S5.1 S02.13 S1 A 88 S5 → [PLU] SHOP NAME FILE 44 Program 2nd line of this shop name. Enter shop name for the 2nd line.(Ex. “TEL:57234888”) Store Shop Name File 1,Back to S mode. SM 110 PROGRAM MODE 3.9.2 Delete Shop Name File At Shop Name programming mode, enter existing Shop Name Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S5 → SHOP NAME FILE [*] S5.0 SHOP 0 NO SET [1] S5.0 SHOP 1 NO SET [-] S5.0 SHOP DEL ? Y-C N-T [C] S5 → SHOP NAME FILE [MODE][MODE] [MODE] [5] or [》] four times Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Shop Name File can not be deleted. 45 REMARK Enter S mode. Lamp S turns on. Shop name File mode is MENU 5 in S mode. Enter Shop Name File programming mode. Enter shop name file 1.(Ex. No.1) Enter deleting mode. [C] for Yes, [T] for No. Delete Shop Name File 1,back to S mode. SM 110 PROGRAM MODE 3.10 Advertisement File Advertisement message is the sales promotional description on the label, such as “FOR BARBECUE” or “FRESH”. Advertisement message is printed in the print area of the Commodity Name. If Commodity Name occupies all of the print area, there will be no room for the Advertisement Message and it will therefore not be printed. Maximum 2 lines can be programmed for each Advertisement Message and up to 64 (Advertisement # 1~64) advertisement messages are available. To print advertisement message on a label, [ADVERTISEMENT] Function Key must be assigned to a preset key in advance. Note: Advertisement message print on all label can be set at SPEC 96, printing position can be set at SPEC 14 and printing method can be set at SPEC 15. 3.10.1 Program Advertisement File At Programming Mode, select Advertisement programming mode and then enter new Advertisement number (Ex. 1) programming mode. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S6 → ADVER MESSAGE [*] S6.0 ADVER 0 NO SET [1][*] S6.1 A01.01 [MODE][MODE] [MODE] [6] or [》] five times [T][H][A][N][K][SP] [Y][O][U] S1 A 100 Enter S mode. Lamp S turns on. Select advertisement file programming mode. Enter advertisement File programming mode. Enter the advertisement File No.1(Ex.No.1) Enter the advertisement as the same S6.1 A01.10 K YOU S1 A 91 procedures as Commodity Name Entry. (Ex. “THANK YOU”) [SIZE] S6.1 A01.10 K YOU S2 A 76 [SIZE]…[SIZE] S6.1 A01.10 K YOU L5 A 21 [*] S6.1 A02.01 S6 → [PLU] REMARK ADVER Press [SIZE] key to change font size of the advertisement file. Change font size to L5. (S1~S5; M1~M5; L1~L5) S1 A 100 Program 2nd line of this advertisement file. MESSAGE Store Advertisement File 1,back to S mode. Note1: Max.2 line per file are available, max.100 letters per line are available. (letters per line depends on font size) 46 SM 110 PROGRAM MODE 3.10.2 Delete Advertisement File At Advertisement programming mode, enter existing Advertisement Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S6 → ADVER MESSAGE [*] S6.0 ADVER 0 NO SET [1] S6.0 ADVER 1 NO SET [-] S6.0 ADVER DEL ? Y-C N-T [C] S6 → ADVER MESSAGE [MODE][MODE] [MODE] [6] or [》] five times Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Advertisement File can not be deleted 47 REMARK Enter S mode. Lamp S turns on. Select advertisement file programming mode. Enter advertisement File programming mode. Enter advertisement File 1.(Ex. No.1) Enter deleting mode. [C] for Yes, [T] for No. Delete advertisement File 1,back to S mode. SM 110 PROGRAM MODE 3.11 Vender File Vender file is used for programming names of operators. Maximum 16 characters can be entered per Vender name. A programmed Vender number can be assigned to a preset key. The Vender Number or Name (Depend on Spec 21 setting) will be printed on the label, if selected label format with print area for Vender Number and the programmed Vender name can be printed on receipt when SPEC 21 set to NAME. OPERATION [MODE][MODE] [MODE] [7] or [》] six times [*] DISPLAY PT kg $/kg $ S1 → PLU FILE S7 → VENDER FILE S7.0 CLERK 0 NO SET REMARK Enter S mode. Lamp S turns on. Select Vender file programming mode. Enter Vender File programming mode. Select vender key.(Ex. V1) [1][*] S7.1 CLERK 1 NAME 0 Program operator name for Vender 1. [M][I][K][E] [PLU] S7.1 CLERK MIKE NAME 4 S7 → VENDER FILE Note1: V1 – V99 can be programmed 48 Enter operator name for V1.(Ex. “MIKE”) Store Vender File V1,back to S mode. SM 110 PROGRAM MODE 3.12 Program Date And Time The built-in clock system can automatically work once they are set. Date (Month/Day/Year): 2 digits for each part; Time (Hour/Minute): 2 digits for each part. OPERATION [MODE][MODE] [MODE] [8] or [》] seven times [*] DISPLAY PT kg $/kg $ S1 → PLU FILE S8 → DATE AND TIME P8.0 DATE 010100 MMDDYY REMARK Enter S mode. Lamp S turns on. Select Date and Time programming mode. Enter Date and Time programming mode. Set Month 08, Day 19 and [0][8][1][9][0][4][*] P8.1 TIME 0000 HHMM Year 04. (Ex. 2004-08-19) Set Hour 9,Minute 05. [9][0][0][*] S8 → DATE AND TIME Store Date and Time, back to S mode. 49 SM 110 PROGRAM MODE 3.13 Special Message File Special Message can be used as a description on the label such as receipt, which can be assigned in each PLU. Since standard format does not have a print area set for Special Message, Special Message cannot be printed when using these formats. To print Special Message on the label, it is required to use a Free Format with a Special Message print area programmed. Maximum 16 special messages can be programmed with each up to 8 programmable lines. Number of line is depends on the size of the print area or Character Size entry. The default Special Number print on Receipt can be set at SPEC 112 and printing position can be set at SPEC 125. Note: If SPEC 43 set to RECEIPT, maximum 8 lines can be programmable for each Special Message Number and without select a required Free Format. 3.13.1 Program Special Message File At Programming Mode, select Special Message programming mode and then enter new Special Message number (Ex. 1) programming mode. *For edit, enter existing Special Message number. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S9 → SP MESSAGE [*] S9.0 SP MG 0 NO SET [1][*] S9.1 M01.01 [MODE][MODE] [MODE] [9] or [》] eight times [M][A][D][E][SP][I][N ][SP][C][H][I][N][A] S1 A 100 Enter S mode. Lamp S turns on. Select special message file programming mode. Enter special message File programming mode. Enter the special message File No.1.(Ex.No.1) Enter the special message File as the same S9.1 M01.14 CHINA S1 A 87 procedures as Commodity Name Entry. (Ex. “MADE IN CHINA”) [SIZE] S9.1 M01.14 CHINA S2 A 72 [SIZE]…[SIZE] S9.1 M02.01 CHINA M3 A 62 [*] S9.1 M02.01 S9 → [PLU] REMARK S1 A 56 SP MESSAGE 50 Press [SIZE] key to change font size of the special message File. Change font size to M3. (S1~S5; M1~M5; L1~L5) Program 2nd line of this special message File. Store special message File 1,back to S mode. SM 110 PROGRAM MODE 3.13.2 Delete Special Message File At Special Message programming mode, enter existing Special Message Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S9 → SP MESSAGE [*] S9.0 SP MG 0 NO SET [1] S9.0 SP MG 1 NO SET [-] S9.0 SP MG DEL ? Y-C N-T [C] S9 → SP MESSAGE [MODE][MODE] [MODE] [9] or [》] eight times Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Special Message File can not be deleted. 51 REMARK Enter S mode. Lamp S turns on. Select special message file programming mode. Enter special message File programming mode. Enter special message File 1.(Ex. No.1) Enter deleting mode. [C] for Yes, [T] for No. Delete special message File 1,back to S mode. SM 110 PROGRAM MODE 3.14 Ingredient File Ingredients data programmed in this Master Ingredient file can be printed on the Free Format (F1-F99) with ingredient print area. The size of print area will decide the numbers of lines and characters of every line. Maximum 15 lines can be programmed for each Master ingredient data and up to 16 Master Ingredients data can be programmed in this file. Note: Maximum 39 lines can be programmed for each Master Ingredient data when SPEC 43 set to 0. 3.14.1 Program Ingredient File At Programming Mode, select Ingredient programming mode and then enter new Ingredient number (Ex. 1) programming mode. *For edit, enter existing Ingredient number. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S10 → INGR FILE [*] S10.0 INGR 0 NO SET [1][*] S10.1 G01.01 [MODE][MODE] [MODE] [10] or [》] nine times S1 A 100 REMARK Enter S mode. Lamp S turns on. Select Ingredient file programming mode. Enter Ingredient File programming mode. Enter the Ingredient File No.1.(Ex.No.1) Enter the Ingredient File as the [S][U][G][A][R] S10.1 G01.06 SUGAR S1 A 100 same procedures as Commodity Name Entry. (Ex. “SUGAR”) [SIZE] S10.1 G01.06 [*] S10.1 G02.01 [F][L][O][U][R] S10.1 G02.06 FLOUR S1 A95 S10 → INGR FILE [PLU] SUGAR S2 A 95 S1 A 100 52 Press [SIZE] key to change font size of the Ingredient File. Program 2nd line of this Ingredient File. Store Ingredient File 1,back to S mode. SM 110 PROGRAM MODE 3.14.2 Delete Ingredient File At Ingredient programming mode, enter existing Ingredient Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S10 → INGR FILE [*] S10.0 INGR 0 NO SET [1] S10.0 INGR 1 NO SET [-] S10.0 INGR DEL ? Y-C N-T [C] S10 → INGR FILE [MODE][MODE] [MODE] [10] or [》] nine times Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Ingredients File can not be deleted. 53 REMARK Enter S mode. Lamp S turns on. Select Ingredient file programming mode. Enter Ingredient File programming mode. Enter Ingredient File 1.(Ex. No.1) Enter deleting mode. [C] for Yes, [T] for No. Delete Ingredient File 1,back to S mode. SM 110 PROGRAM MODE 3.15 Text File Maximum 20 Texts are available (Text 1~16 are for Item label and text 17~20 are for Total label). Text is used for printing the fixed data on label such as “Unit Price”, “packed date”. Text cannot be printed when using standard format since they do not have any text print area set. You must use a Free Format with a Text print area programmed. Maximum 2 lines per text can be programmed and number of line is depends on the size of print area of the selected label format or Character Size entry. Note: Print Text 5 to 16 on Total label can be set at SPEC 332 setting. 3.15.1 Program Text File At Programming Mode, select Text programming mode and then enter new Text number (Ex. 1) programming mode. *For edit, enter existing Text number. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S11 → TEXT FILE [*] S11.0 TEXT 0 NO SET [1][*] S11.1 T01.01 [MODE][MODE] [MODE] [11] or [》] ten times S1 A 100 REMARK Enter S mode. Lamp S turns on. Select Text file programming mode. Enter Text File programming mode. Enter the Text File No.1.(Ex.No.1) Enter the Text File as the same [P][A][C][K][A][G][E] S11.1 T01.08 CKAGE S1 A 93 procedures as Commodity Name Entry. (Ex. “PACKAGE”) [SIZE] S11.1 T01.08 CKAGE S2 A 78 [SIZE]…[SIZE] S11.1 T01.08 CKAGE S5 A 53 [*] S11.1 T02.01 [D][A][T][E] S11.1 T02.05 DATE S1 A 52 S11 → TEXT FILE [PLU] S1 A 56 54 Press [SIZE] key to change font size of the Ingredient File. Change font size to S5. (S1~S5; M1~M5; L1~L5) Program 2nd line of this Ingredient File. Store Text File 1,back to S mode. SM 110 PROGRAM MODE 3.15.2 Delete Text File At Text programming mode, enter existing Text Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE S11 → TEXT FILE [*] S11.0 TEXT 0 NO SET [1] S11.0 TEXT 1 NO SET [-] S11.0 TEXT DEL ? Y-C N-T [C] S11 → TEXT FILE [MODE][MODE] [MODE] [11] or [》] ten times Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Text File can not be deleted. 55 REMARK Enter S mode. Lamp S turns on. Select Text file programming mode. Enter Text File programming mode. Enter Text File 1.(Ex. No.1) Enter deleting mode. [C] for Yes, [T] for No. Delete Text File 1,back to S mode. SM 110 PROGRAM MODE 3.16 Free Format File The Free Format enables you to design your own label format, by setting print angles, print positions, character size and other programmable items. You can create a new format by copying an existing label format and use it as a base or make a totally new label format. 3.16.1 General Information Label format within the following height and width can be created. • Up to 99 Free Formats can be stored in the memory, apart from the other 16 standard formats. • Standard format can be used as a basic format for creating a new format. • Print position of each item is programmed using "mm". • One Item label or one Total label is available for each Free Format number (F1~F99). • 4 Print Angles can be set for all item data: 0, 90, 180 and 270 degrees. 56 SM 110 3.16.2 Print Area, Print Position and Print Angles PROGRAM MODE All changeable item data should be programmed 8mm above the bottom of the label. The bottom 8 mm of the label should be used for invariable data such as shop name, since this area is printed when issuing the last label. Please do not program any item closer than 1mm to the edges of the label. The print position of each item is determined by setting the interval from "0" point (X=0, Y=0) to the base position of the programmed item. X and Y values need to be entered by "mm". Print Area The item data cannot be printed at the bottom 10 mm of labels. Pre-print data such as shop name or logo data is programmed at the bottom 10mm. Also the item data should not be printed within 1mm from the left edge or the right edge of the label as the following drawing shows. 57 SM 110 Print Position PROGRAM MODE The printing position of each item data is decided by setting the distance from 0 point (X=0, Y=0) to the base position (X value, Y value). Print Angle Print angle of each Print Item can be selected from 4 different angles, 0 degree, 90 degree, 180 degree, and 270 degree. A whole format base or each Item Data-base may set print angle. According to the selected print angle, the status of print position differs as the following samples. 58 SM 110 PROGRAM MODE 3.16.3 Programming Parameter Of Print Items Print Item for Item Label Up to 82 different item data can be programmed in Item Label Format and is used for printing at Manual mode and pre-pack mode. Ty pe Display 1. PLU NO 1 PLUno 45. PRICE BEFORE DISCOUNT 1 2. PRICE (-TAX) 1 PRICE 46. UNIT PRICE BEFORE DISCOUNT 1 3. UNIT PRICE 1 UN PR 47 ~ 56.IMAGE 1 ~ IMAGE 10 2 4. WEIGHT 1 WT 57. AVERAGE PRICE 1 5. QUANTITY 1 QTY 58. AVERAGE WEIGHT 1 6. PACKED DATE 1 PDATE 59. BONUS POINT 1 BONUS 7. PACKED TIME 1 PTIME 60. EURO UNIT PRICE 1 EUR U 8. COMMODITY 2 COMM 61. EURO TOTAL PRICE 1 EUR T 9. QUANTITY UNIT 1 QTYSY 62. EURO CALULATION 1 EUR C 10. SELL BY DATE 1 SDATE 63. DUPLICATE TOTAL PRICE 1 11. SELL BY TIME 1 STIME 64. DUPLICATE UNIT PRICE 1 12. BARCODE 3 BARCD 66. BORN COUNTRY 1 BORN 13. SHOP NAME 2 SHOPN 67. FATTEN COUNTRY 1 FAT 14. DISCOUNT VALUE 1 DISCT 68. SLAUGTHER HOUSE 1 SLAUG 15. USED BY DATE 1 UDATE 69. CUTTING HALL 1 CUT H 16. LOGO 2 LOGO 70. REFER NO 1 FEF D 17. MAIN GROUP CODE 1 MG CD 71. ORIGIN 1 ORIGI 18. DEPARTMENT CODE 1 DEPT 72. TEMPERATURE 1 TEMP 19. SCALE NUMBER 1 SCLNO 73. MULTI BARCODE 1 3 M1BAR 20. INGREDIENT 2 INGR 74. MULTI BARCODE 2 3 M2BAR 21. SPECIAL MESSAGE 2 SP MG 75. SERIAL NO 1 22. FRAME 1 4 FRM 1 76. GROSS WEIGHT 1 23. FRAME 2 4 FRM 2 77. REWRAP 1 24. TARE 1 TARE 78. KIND 1 25. CLERK 1 CLERK 79. CATEGORY 1 26 ~ 41. TEXT 1 ~ TEXT 16 2 TXT?? 80. BREED 1 42. PRICE (+ TAX) 1 PRTAX 81. CONTACT 1 43. TAX RAGE 1 TAX R 82. GTIN 1 44. PLACE 2 PLACE Item Data Item Data Ty pe Display IMG?? Note: When SPEC 158 set to "ENABLE" the Screen of Item no.2 will change to "DISCOUNT PRICE" & item Number 3 change to "DISCOUNT UNIT PRICE", and Item Number of 45 & 46 will appears. 59 SM 110 Print Item for Total Label PROGRAM MODE Up to 28 different item data can be programmed in Total Label Format and is used for printing multiple transaction labels for counter sales at Manual mode, Sub-Total and Grand Total at Pre-pack mode. Item Data Type Display Item Data Type Display 1. PLU NO 1 PLUno 15. PRICE (- TAX) 1 P-TAX 2. PACK DATE 1 PDATE 16. EXCLUDED TAX AMOUNT 1 ATX 3. WEIGHT 1 WT 17. INCLUDED TAX AMOUNT 1 VTX 4. QUANTITY 1 QTY 18. EURO TOTAL PRICE 1 ERUO 5. QUANTITY UNIT 1 QTYSY 19. USED DATE 1 UDATE 6. PRICE (+ TAX) 1 PRTAX 20. BORN COUNTRY 1 BORN 7. PACKED TIME 1 PTIME 21. FATTEN COUNTRY 1 FAT 8. TOTAL TITLE 1 TOTAL 22. SLAUGTHER HOUSE 1 SLAUG 9. BARCODE 3 BARCD 23. CUTTING HALL 1 CUT H 10. CLERK 1 CLERK 24. REFER DATE 1 REF D 11. TEXT 17 2 TXT17 25. ORIGINAL COUNTRY 1 ORIGI 12. TEXT 18 2 TXT18 26. MULTI BARCODE 1 3 M1BAR 13. TEXT 19 2 TXT19 27. MULTI BARCODE 2 3 M2BAR 14. TEXT 20 2 TXT20 28. SERIAL NO 1 Programmable Data Type Programmable data Type 1 Type 2 Type 3 Type 4 X position YES YES YES YES Y position YES YES YES YES Angle YES YES YES NO Status YES YES YES YES Character Size YES NO NO NO Width NO YES NO NO Height NO YES YES NO Thickness NO NO NO YES 60 SM 110 PROGRAM MODE 3.16.4 Free Format Entry At Programming Mode, select Free Format programming mode and then enter new Free Format number (Ex. 1) programming mode. *For edit, enter existing Free Format number. Basic Setting: (width, height, angle and label type) OPERATION [MODE][MODE] [MODE] [1][2] DISPLAY PT kg $/kg $ S1 → PLU FILE S12 → FREE FORMAT REMARK Enter S mode. Lamp S turns on. Select S12.0 FREE 0 1-99 Format setting programming mode. Enter [*] Free Free Format setting programming mode. Select Free Format File Number. [1][*] S12.1 LABEL 0 WT MM [4][8][*] S12.2 LABEL 0 HT MM [3][5][*] S12.3 LABEL 0 DG ANGLE Enter the Free Format File No.1.(Ex.No.1) Enter Label print width.(Ex.48mm) Enter Label print height.(Ex.35mm) [<<] or [>>] key can change the [<<] or [>>] S12.3 LABEL 90 DG ANGLE selection of label angle. (0,90,180,270 degree) [*] S12.4 LABEL ITEM LABEL [<<] or [>>] S12.4 LABEL TOTAL LABEL Label angle is turned 90 degree. Select label type. (Item Label; Total Label) Enter item setting. [*] S12.5 PLUno ← 1 F ITEM Refer to Base Type 1 to 4 setting. 61 SM 110 Base Type 1: PROGRAM MODE Item data in Data Base Type1 are Numeric data or Fixed data. The print position of item data can be programmed by setting X / Y value, Print angle and Character size. Item Label: PLU No., Price, Unit Price, Weight, Quantity, Packed date, Packed Time, Quantity Symbol, Sell by date, Sell by time, Discount Price, Used by date, MG No., Dept. No., Scale No., Tare Weight, Clerk No., and Text data. Total Label: PLU No., Packed date, Total Weight, Total quantity, Quantity symbol, Total Price, Packed time, Letter of TOTAL, Clerk No., and Text data. OPERATION DISPLAY PT kg $/kg $ REMARK Continued from the procedure Basic Setting: (width, height, angle and label type) ← S12.5 PLUno [*] S12.5 PLUno 0 X MM Enter X value.(Ex.1mm) [1][*] S12.5 PLUno 0 Y MM Enter Y value.(Ex.1mm) [1][*] S12.5 PLUno 0 DG ANGLE [>>][*] S12.5 PLUno 0 STATUS [7][*] S12.5 PLUno S1 CHAR SIZE 1 F ITEM Item setting: PLU No. Select print angle.(Ex.90 degree) Enter print status.(Ex. All item print) Select the character size.(Ex. S5) [<<] or [>>] key can change the [>>] four times S12.5 PLUno S5 CHAR SIZE selection of the character size. (S1~S5; M1~M5; L1~L5) [*] S12.5 ← PLUno Note 1: STATUS TYPE: 0: NO Print 1 F ITEM Enter next item setting. 3: Weighing Item 4: Non-weighing Item 7: All Item Print Note 2: Up to 41 different item data can be programmed in Item Label Format and is used for printing at Manual Mode and Pre-pack Mode. Note 3: Up to 14 different item data can be programmed in Total Label Format and is used for printing multiple transaction labels for counter sales at Manual Mode, Sub-Total and Grand Total at Pre-pack Mode. Note 4: There are two ways to select the Item Data in Free Format programming by using different keys such as: • Enter the Item data number key. • Press [X] key or [−] key to search the Item data. 62 SM 110 Base Type 2 PROGRAM MODE Item data in Base Type 2 are Alpha-numeric data. The print position of item data can be programmed by setting the max. print area , X / Y value, width of print area from X value, height of print area from Y value and print angle. Item Label: Commodity Name, Shop Name, Logo, Ingredient, and Special Message. OPERATION DISPLAY PT kg $/kg REMARK $ Continued from the procedure Basic Setting: (width, height, angle and label type) ← S12.5 SHOPN [*] S12.5 SHOPN 0 X MM Enter X value.(Ex.10mm) [1][0][*] S12.5 SHOPN 0 Y MM Enter Y value.(Ex.1mm) [1][*] S12.5 SHOPN 0 DG ANGLE 13 F ITEM Item setting: Shop name. Select print angle.(Ex.180 degree) Enter width value. [>>][>>][*] S12.5 SHOPN 0 WT MM The width of shop name printing area is 20mm.(Ex. 20mm) Enter height value. [2][0][*] S12.5 SHOPN 0 HT MM The height of shop name printing area is 15mm.(Ex. 15mm) [1][5][*] S12.5 SHOPN 0 STATUS [7] S12.5 SHOPN 7 STATUS [*] S12.5 SHOPN ← 13 F 63 ITEM Enter print status.(Ex. All item print) The status of shop name printing area is all item printing. Enter next item setting. SM 110 PROGRAM MODE Base Type 3 Item data in Data Base 3 is Barcode data. The print position of bar-code data can be programmed by setting X / Y value, width of Barcode from X value, height of Barcode from Y value and print angle. OPERATION DISPLAY PT kg $/kg $ REMARK Continued from the procedure Basic Setting: (width, height, angle and label type) ← S12.5 BARCD [*] S12.5 BARCD 0 X MM Enter X value.(Ex.5mm) [5][*] S12.5 BARCD 0 Y MM Enter Y value.(Ex.20mm) [2][0][*] S12.5 BARCD 0 DG ANGLE 12 F ITEM Item setting: Barcode. Select print angle.(Ex.90 degree) Enter height value. [>>][*] S12.5 BARCD 0 HT MM The height of shop name printing area is 25mm.(Ex. 25mm) [2][5][*] S12.5 BARCD 0 STATUS [7] S12.5 BARCD 7 STATUS [*] S12.5 ← BARCD 12 F 64 ITEM Enter print status.(Ex. All item print) The status of BARCODE printing area is all item printing. Enter next item setting. SM 110 PROGRAM MODE Base Type 4 Item data in Data Base 4 is Frame data. The print position of Frame data may be programmed by setting X value, Y value, X1 value, Y1 value [the opposite point against the point (X,Y) on a diagonal line], and line weight. OPERATION DISPLAY PT kg $/kg REMARK $ Continued from the procedure Basic Setting: (width, height, angle and label type) ← S12.5 FRM 1 [*] S12.5 FRM 1 0 X MM Enter X value.(Ex.10mm) [1][0][*] S12.5 FRM 1 0 Y MM Enter Y value.(Ex.1mm) 22 F ITEM Item setting: Frame 1. Enter X1 value. [1][*] S12.5 FRM 1 0 X1 MM The X1 of frame 1 printing area is 20mm.(Ex. 20mm) Enter Y1 value. [2][0][*] S12.5 FRM1 0 Y1 MM The Y1 of frame 1 printing area is 15mm.(Ex. 15mm) [1][5][*] S12.5 FRM 1 0 STATUS Enter print status.(Ex. All item print) Enter line weight. [7][*] S12.5 FRM 1 0 T MM The line weight of frame 1 printing area is 2mm.(Ex. 2mm) [2][*] S12.5 FRM 1 ← 22 F 65 ITEM Enter next item setting. SM 110 PROGRAM MODE 3.16.5 Free Format Copy Function At Free Format programming mode, Select Copy existing Label Format and then select the existing label format you want to be copy (Ex. T7) and go to next selection. OPERATION DISPLAY REMARK PT kg $/kg $ S1 → PLU FILE Enter S mode. [1][2][*] S12.0 FREE 0 1-99 Enter X value.(Ex.10mm) [1] S12.0 FREE 1 1-99 [X] S12.0 FREE [7] or [<<] and [>>] [*][PLU] NO 0 COPY Enter the Free Format File No.1.(Ex.No.1) Press [X] key to enter free format copy function. Press [7] or [<<] and [>>] to S12.0 FREE T7 7 COPY select the existing label format you want to be copy.(Ex. T7) S12 → FREE FORMAT Store the free format file 1, back to S mode. Note1: Another way to select the existing label format to copy by press [<<] Key or [>>] Key. 3.16.6 Free Format Delete Function The Free Format Label cannot be deleted when the label is linked to existing PLU file. At Free Format programming mode, enter existing Free Format Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S12.0 FREE 0 1-99 [1] S12.0 FREE 1 1-99 [-] S12.0 FREE DEL ? Y-C N-T [C] S12.0 → FREE FORMAT Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Free Format File can not be deleted. 66 REMARK Enter Free Format programming mode. Enter free format file number 1. Enter delete mode. [C] for Yes,[T] for No. Delete free format file 1, back to S mode. SM 110 PROGRAM MODE 3.16.7 Sample of program a format by modifying the existing format You can create your desired label format by copying an existing format and modifying it to your needs. 67 SM 110 PROGRAM MODE Following is the example on how to customize standard format T8 to your needs. E.g. Add an ingredient text and remove the PLU # from the standard Item Label Format OPERATION DISPLAY PT kg $/kg $ S12 → FREE FORMAT REMARK At Free Format program mode Enter [*] S12.0 FREE 0 1-99 Free Format setting programming mode. Select Free Format File Number. [8] S12.0 FREE [X] S12.0 FREE [8] or [<<] and [>>] [*] 8 1-99 NO COPY 0 Enter the Free Format File No.1.(Ex.No.8) Press [X] key to enter free format copy function. Press [8] or [<<] and [>>] to S12.0 FREE T8 8 COPY select the existing label format you want to be copy.(Ex. T8) S12.1 LABEL 56 WT MM Change label width (Ex. No change). Change label height (Ex. No [*] S12.2 LABEL 55 HT MM [*] S12.3 LABEL 0 DG ANGLE [*] S12.4 LABEL ITEM LABEL [*] S12.5 PLUno [*][*][*][*] S12.5 PLUno 7 STATUS [C]or[0] S12.5 PLUno 0 STATUS [*][*] S12.5 PLUno ← 1 F ITEM [8] S12.5 COMM ← 8 F ITEM F 1 ← ITEM change). Change print angle.( Ex. No change) Select Item Label. Enter item setting. Enter PLU Number print Status mode. Change the status to NO PRINT Save the setting and go to next selection. Select Commodity Name program mode. Enter Y position setting mode [*][*][3][2] S12.5 COMM 23 Y MM and change it from 23 mm to 32 mm and go to next selection. [*] S12.5 COMM 0 DG ANGLE 68 Change print angle.( Ex. No change) SM 110 OPERATION PROGRAM MODE DISPLAY PT kg $/kg REMARK $ Enter TTL Height setting mode, [*][*][1][5] S12.5 COMM 15 HT MM change the height from 21 mm to 15 mm and go to next selection. [*] S12.5 COMM 7 STATUS [*] S12.5 COMM ← 8 [2][0] S12.5 INGR ← 20 [*] S12.5 INGR 0 X MM [2][*] S12.5 INGR 0 Y MM [2][3][*] S12.5 INGR 0 DG ANGLE [*] S12.5 INGR 0 WT MM [5][4][*] S12.5 INGR 0 HT MM [1][0][*] S12.5 INGR 0 STATUS [7][*] S12.5 INGR [PLU] S12 → Enter print status. ( Ex. No change) Save the Commodity Name print F ITEM F ITEM setting. Select Ingredient program mode. Enter Ingredient programmable mode. Enter X Position value (Ex. 2mm) and go to next selection. Enter Y Position value (Ex. 23mm) and go to next selection. Change print angle (Ex. No change). Enter WIDTH value (Ex. 54mm) and go to next selection. Enter HEIGHT value (Ex. 10mm) and go to next selection. Select print status (Ex. 7 = ALL ← F ITEM 20 FREE FORMAT 69 PRINT) and go to next selection. Save the Free Format number 8. SM 110 PROGRAM MODE 3.17 Place File PLACE file is used for programming a short text describing the place of production. The number of Characters possible to enter depends on the PLACE print area size and the character size used. Place will be printed in the free room of Commodity Name print area if selected label format without Place print area. Maximum 99 places (Place number 1 ~ 99) can be programmed, each with 1 line. 3.17.1 Program Place File At Programming Mode, select Place programming mode and then enter new Place number (Ex. 1). *For edit, enter existing Place number. DISPLAY OPERATION REMARK PT kg $/kg $ S1 → PLU FILE [1][5][*] S15.0 PLACE 0 NO SET Enter Place File programming mode. [1][*] S15.1 P01.01 S1 A100 Enter place file No.(Ex. No.1) Enter S mode. Enter the Place File as the same [M][A][D][E][SP]…… S15.1 P01.13 DIGI S1 A 88 procedures as Commodity Name Entry. (Ex. “MADE IN DIGI”) [SIZE][SIZE]… [PLU] S15.1 P01.13 DIGI S5 A 48 S15 → PLACE FILE Change font size to S5. (S1~S5; M1~M5; L1~L5) Store Place File 1,back to S mode. 3.17.2 Delete Place File At Place programming mode, enter existing Place Number (Ex. 1) to be deleted. OPERATION DISPLAY REMARK PT kg $/kg $ S15.0 PLACE 0 NO SET Enter Place File programming mode. [1] S15.0 PLACE 1 NO SET Enter Place File number 1. [-] S15.0 FREE DEL ? Y-C N-T [C] S15 → PLACE FILE Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Place File can not be deleted. 70 Enter delete mode. [C] for Yes,[T] for No. Delete Place File 1, back to S mode. SM 110 PROGRAM MODE 3.18 Machine Setting OPERATION DISPLAY REMARK PT kg $/kg $ S1 → PLU FILE Enter S mode. [1][6][*] S16.0 RATE 0.00 DISC Program Machine Code. [5][0][0] S16.0 RATE 5.00 DISC S16 → MACHIN SETTING [*] Note1: 0% to 99.99% are available for Default Discount Rate. 71 Enter default discount rate.(Ex. 5.00%) Store machine setting, back to S mode. SM 110 PROGRAM MODE 3.19 Logo File Logo is the trademark of the shop, which will be printed in Label or Receipt. Logo will be printed on the top of receipt and on the left side of shop name on label. (When printing Logo data on Free Format Label, set the print area of Logo data on the Free Format in advance.) Logo data can be programmed up to 4 logos. When using 4 logos for label, assign the LOGO KEY to preset key in advance. A logo data is formed by a pattern of dots (128 horizontal dots and 64 vertical dots.) However, since the Label logo data is printed within the limits, which are programmed in label formats, program the logo data within the limits of print area on the format. Note: All standard formats have 37 dots x 30 dots for logo print area. 3.19.1 Pre-programming Logo Data 1) Prepare a section paper with 128 horizontal dots and 64 vertical dots. 2) When programming Label Logo, draw the limit of the Logo print area. 3) Draw the desired logo design in the section paper by filling the section with dot. (The dots are necessary to seize the image of the actual logo before programming.) Example: DIGI Logo for label (37 x 30 dots) 72 SM 110 PROGRAM MODE 3.19.2 Program Display & Keys Function Program Display for Logo Set Up The following display appears when entering Logo Program Mode. Key Function for LOGO Set Up [0] ------- Clear a dot. [1] ------- Fill a dot. [<<] ------- Move the cursor to left. [I] [>>] ------- Move the cursor to right. [J] [《] ------- Move the cursor to up. [K] [》] ------- Move the cursor to down. [L] [*] ------- Move up to the first dot in the next line. [PLU] ------- Store the Data. 73 SM 110 PROGRAM MODE 3.19.3 Programming Order 1) After filling a section, programming status (the position of the cursor) moves to the next dot automatically. 2) When the programming status reached to the last dot (128 horizontal dots), or [*] key is depress, the programming status moves to the first left section on the next upper line automatically. 3.19.4 Program Logo File At Programming Mode, select Logo programming mode and enter new Logo number. (Ex. 1) *For edit, enter existing Logo number. OPERATION DISPLAY REMARK PT kg $/kg $ S1 → PLU FILE Enter S mode. [1][7][*] S17.0 LOGO 0 NO Enter Logo File programming mode. SET Enter Logo File number.(Ex. 1) [1][*] S17.1 LOGO 0 X-POS Enter X position.(Ex. 7 dots) [7][*] S17.2 LOGO 0 Y-POS Enter Y position.(Ex. 1dots) Set Fill or Clear dots you want and the save the [1][*] S17.3 LOGO 000000 007-01 setting and go to next upper line (Y 02).(Ex.11101110001) [1][1]……[0][1][*] S17.3 LOGO 000000 001-02 Press [>>] key to move the cursor to next dot. If necessary to change the position of the Press[>>]key 6 times S17.3 LOGO 000000 007-02 cursor been set, the following procedure is required. Change the Horizontal start position (Ex. 5 [-][-] S17.3 LOGO 7 X-POS [5][*] S17.3 LOGO 2 Y-POS Change the Vertical start position (Ex. NO CHANGE). [*] S17.3 LOGO 000000 005-02 After complete program Logo data, save it. S17 → LOGO FILE Store the Logo 1 data, back to S mode. [PLU] dots). Note1: If you want to exit without saving, press [◇] key follow by [C] key. 74 SM 110 PROGRAM MODE 3.19.5 Delete Logo File At Logo programming mode, enter existing Logo Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S17.0 LOGO 0 NO SET [1] S17.0 LOGO 1 NO SET [-] S17.0 LOGO DEL ? Y-C N-T [C] S17 → LOGO FILE Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Logo File can not be deleted. 75 REMARK Enter Logo File programming mode. Enter Logo File number 1. Enter delete mode. [C] for Yes,[T] for No. Delete Logo File 1, back to S mode. SM 110 PROGRAM MODE 3.20 Tax File This function enables you to program consumption tax rate included or excluded in the price. Up to 10 Tax Numbers (1 - 10) can be programmed. The programmed Tax rates (Tax Number) that are linked to a Main Group will apply for all PLU's in that Main Group or set the Tax Number in individual PLU File. Tax Rates can be entered between 00.00 % - 99.99 %. To enable TAX programming mode, SPEC 603 must set to 1 (TAX) in advance. There are two types of Taxes: • ADD ON TAX: Tax is added to the Total Price. • VAT TAX: Tax is included in the Total Price. Note: If you want print PRICE WITH TAX on Item Label, the selected label format must has print area for Price + Tax and SPEC 659: SELECTION OF ITEM PRICE PRINTING must set to ITEM PRICE AFTER TAX in advance. 3.20.1 Program Tax File At Programming Mode, select TAX programming mode and then enter new Tax number (Ex. 1) programming mode. *For edit, enter existing Tax number. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE REMARK Enter S mode. Enter Tax File programming [1][8][*] S18.0 TAX 0 NO SET mode. Enter Tax File number.(Ex. 1) Enter default tax rate.(Ex. [1][*] S18.1 TAX 0.00 INCLUDE [3][0][0] S18.1 TAX 3.00 INCLUDE Select tax type. [<<] or [>>] S18.1 TAX 3.00 EXCLUDE Tax File 1 is value added tax. S18 → TAX FILE [PLU] Note1: 0 % to 99.99 % are available for Default Tax Rate. Note2: [<<] and [>>] key can change the tax type. (Include / Exclude) 76 3.00%) Store the Tax File 1 data, back to S mode. SM 110 PROGRAM MODE 3.20.2 Delete Tax File When the Tax Number linked to the existing Main Group File or PLU File, the Tax Number cannot be deleted. In addition, the Tax Number 1 cannot be deleted. At Tax programming mode, enter existing Tax Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S18.0 TAX 0 NO SET [1] S18.0 TAX 1 NO SET [-] S18.0 TAX DEL ? Y-C N-T [C] S18 → TAX FILE Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Tax File can not be deleted. 77 REMARK Enter Tax File programming mode. Enter Tax File number 1. Enter delete mode. [C] for Yes,[T] for No. Delete Tax File 1, back to S mode. SM 110 PROGRAM MODE 3.21 Scroll Message File Maximum 100 characters can be programmed for each scroll message and up to 9-scroll message data are available in scroll message file. 3.21.1 Program Scroll Message File At Programming Mode, select Scrolling Message programming mode and then enter new Scroll Message number (Ex. 1) programming mode. *For edit, enter existing Scroll Message Number. DISPLAY OPERATION PT kg $/kg $ S1 → PLU FILE REMARK Enter S mode. Enter Scrolling Message programming [1][3][*] S13.0 SC MG 0 NO SET mode. Enter Scrolling Message number.(Ex. 1) [1][*] S13.1 SC MG 0 Enter Scroll Message. [W][E][L][C][O][M][E S13.1 ][SP][T][O]…… SC MG STORE 21 (Ex. “WELCOME TO DIGI STORE”) [PLU] S13 → SCROLL MESSAGE Store the Scroll message 1 data, back to S mode. 3.21.2 Delete Scroll Message File When the Scroll message number is linked to Scroll Sequence, it can’t be deleted. At Scrolling Message program mode, enter existing Scroll Message Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S13.0 SC MG 0 NO SET [1] S13.0 SC MG 1 NO SET [-] S13.0 SC MG DEL ? Y-C N-T [C] S13 → SCROLL MESSAGE Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Scroll Message File can not be deleted. 78 REMARK Enter Scrolling Message programming mode. Enter Scrolling Message number.(Ex. 1) Enter delete mode. [C] for Yes,[T] for No. Delete Scrolling Message File 1, back to S mode. SM 110 PROGRAM MODE 3.22 Scroll Sequence File Scroll Sequence # 1 to # 3 is available. Each scroll sequence consists of up to three kinds of Messages. Scroll Sequence means the scroll display order and display appearance of the programmed scroll message. 3.22.1 Program Scroll Sequence File At Programming Mode, select Scrolling Sequence programming mode and then enter new Scroll Sequence number (Ex. 1) programming mode. *For edit, enter existing Scroll Sequence Number. OPERATION DISPLAY PT kg $/kg $ S1 → PLU FILE [1][4][*] S14.0 SC SQ 0 NO SET [1][*] S14.1 SC SQ MSG NO 000 [1][2][3][*] S14.2 SC SQ ATTRIB 123 000 REMARK Enter S mode. Enter Scrolling Sequence programming mode. Enter Scrolling Sequence file number.(Ex. 1) Enter existing Scrolling Message Number.(Ex. 1, 2, 3) Select Scrolling pattern for each [1][2][3][*] S14.2 SC SQ SPEED 123 000 Scrolling Message. (Ex. MSG#1=1, MSG#2=2 & MSG#3=3) Select Scrolling Rate. (Ex. [1][2][0] S14.2 SC SQ SPEED 123 120 MSG#1=1:NORMAL,MSG#2 =2:FAST and MSG#3=0:SLOW) [PLU] S14 → SCROLL The scrolling pattern is as following. 0: L–SCROLL: Maximum100 characters 1: BLINKING: Maximum 25 characters 2: STATIS: Maximum 25 characters 3: R –SCROLL: Maximum100 characters 4: WIPE IN: Maximum 25 characters 79 SEQUENC Store the Scroll message 1 data, back to S mode. SM 110 PROGRAM MODE 3.22.2 Enable or Disable Scroll Sequence File This Function is used to enable the programmed Scroll Message data by Scroll Sequence Number shows on the Display in Registration Mode when scale in idle time. The Scroll Message, Scrolling Pattern and Speed will follow Scroll Sequence Number setting. Enable Scroll Sequence File At Scroll Sequence programming Mode, enter Scroll Sequence Number you want (Ex. 1). OPERATION [1] [PLU] DISPLAY PT kg $/kg $ S14.0 SC SQ 0 NO SET S14.0 SC SQ 1 NO SET S14 → SCROLL SEQUENC REMARK Enter Scrolling Sequence programming mode. Enter Scrolling Sequence file number.(Ex. 1) Enable Scrolling Sequence Number 1, back to S mode. Note1: If you want to change the Scroll Sequence number, enter new sequence number follow by press [PLU] key. Disable Scrolling Message At Scroll Sequence programming Mode, enter Scroll Sequence Number you want (Ex. 0). OPERATION [0] [PLU] DISPLAY PT kg $/kg $ S14.0 SC SQ 0 NO SET S14.1 SC SQ 0 NO SET S14 → SCROLL SEQUENC 80 REMARK Enter Scrolling Sequence programming mode. Enter Scrolling Sequence file number.(Ex. 0) disable Scrolling Sequence Number 1, back to S mode. SM 110 PROGRAM MODE 3.22.3 Delete Scroll Sequence Number When the Scroll Sequence Number to be deleted is in Used, it can’t be deleted. At Scroll Sequence programming mode, enter existing Scroll Sequence Number (Ex. 1) to be deleted. OPERATION DISPLAY PT kg $/kg $ S14.0 SC SQ 0 NO SET [1] S14.0 SC SQ 1 NO SET [-] S14.0 SC SQ DEL ? Y-C N-T [C] S14 → SCROLL SEQUENC Note1: If you want to cancel the deletion, press [T] key to exit. Note2: Non-existing Scroll Sequence File can not be deleted. 81 REMARK Enter Scrolling Sequence programming mode. Enter Scrolling Sequence file number.(Ex. 1) Enter delete mode. [C] for Yes,[T] for No. Delete Scrolling Sequence Number 1, back to S mode. SM 110 PROGRAM MODE 3.23 ASCII Character Input Method Insert Key-sheet for ASCII Character Input: (For standard version) A/a 1 B/b 2 C/c 3 D/d 4 E/e 5 F/f 6 G/g 7 H/h 8 I/i 9 J/j 0 K/k ! L/l M/m N/n $ O/o % P/p ^ Q/q & R/r * S/s T/t ( ) U/u : V/v = W/w " X/x / Y/y - Z/z \ ?/? + ü/ü ? ?/? < é/é . ?/? > ?/? , à/á € ?/í ó @ ← → Each key includes 3-4 ASCII character. Example: Key [A/a/1/!] includes ASCII character: A, a and 1. Operation ASCII Display Indicate Remarks Depress the key one time INPUT ‘A’ A Lamp P turns on *note 1 Depress the key two times INPUT ‘a’ a Lamp P turns off *note2 Depress the key three times INPUT ‘1’ 1 Lamp P turns off *note3 Note1: Lamp P turning on indicates capital letter is use in PLU programming. Note2: After one letter input, the indicator under the letter is flicker 1.5 seconds. Note3: When the indicator under the letter is flicker, depress the same key can change the input to the next ASCII character. 82 SM 110 PROGRAM MODE 3.24 ASCII Code Input Method ASCII Code Input Method is another kind of input method for ASCII character entry. [CODE] Key can switch the input method between ASCII Code Input Method and ASCII Character Key In Method. Example: Use the ASCII Code Input Method to entry commodity name. (CAKE) DISPLAY OPERATION REMARK PT kg $/kg $ …… …… …… …… S1.3 C01.01 [CODE] S1.3 C01.01 A- S1 A 22 [6][7] S1.3 C01.02 A- S1 A 21 [6][5] S1.3 C01.03 A- S1 A 20 [7][5] S1.3 C01.04 A- S1 A 19 [6][9] S1.3 C01.05 A- S1 A 18 …… S1 A 22 …… Enter commodity name. Press [CODE] to switch to ASCII Code Input . ASCII Code 67 figures 65 figures 75 figures 69 figures Character ‘C’. ASCII Code Character ‘A’. ASCII Code Character ‘K’. ASCII Code Character ‘E’. Switch to key in method. [CODE] S1.3 C01.01 CAKE S1 A 18 The inputted characters will be displayed in the Unit Price window. …… …… …… …… …… …… Note1: Decimal digital from 32 to 255 can be entered. Each Decimal digital figures one ASCII Character. Note2: Different Countries can refer to the local ASCII Code List. 83 SM 110 REGISTRATION MODE 4. REGISTRATION MODE 4.1 ON/OFF 1 - ZERO OPERATION 2 - NET 3 - FIX T KEYS PT 4 - FIX P Kg $/kg $ 1 2 3 4 kg Power on. [ON/OFF] 0000 00000 000000 0000000 1111 11111 111111 1111111 2222 22222 222222 2222222 1333 33333 333333 3333333 4444 44444 444444 4444444 5555 55555 555555 5555555 6666 66666 666666 6666666 7777 77777 777777 7777777 8888 88888 888888 8888888 9999 99999 999999 9999999 **** ***** ****** ******* . . . . . , , , , , . . . . . , , , , , . , . . . . , , , , . , . . . . . . , , , , , , ^^^^ ^^^^^ ^^^^^^ ^^^^^^^ 8888 88888 888888 8888888 Stand-by-status. 0.0 0 0 Power off. 0.0 0 0 0.0 0 0.0 0 [ON/OFF] 4.2 Reset and Weighing Check All weighing operations will be performed based on the procedure shown below. Operator should check this operation before any transactions. 1 - ZERO OPERATION 2 - NET KEYS 3 - FIX T PT kg Stand-by-status. Reset the zero point. 0.0 0 0 [REZERO] Kg 4 - FIX P $/kg 0.0 0 0.0 0 $ 1 0.0 0 8888 88888 888888 8888888 Place an item on the platter. (e.g. 1.00kg) [1] [2] [0] Remove the item from platter. 84 0.0 0 0 0.0 0 0.0 0 0.0 0 0.0 0 0 1.0 0 0 0.0 0 0.0 0 0.0 1 0 1.0 0 0 1.2 0 1.2 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2 3 4 SM 110 REGISTRATION MODE 4.3 Tare Subtraction 4.3.1 One touch Tare Subtraction 1 - ZERO 2 - NET KEYS OPERATION 3 - FIX T PT kg Stand-by-status. Put tare (e.g 30 g) on platter. Subtract the tare weight. [T] Remove the tare weight Clear the tare weight. [T] Kg 4 - FIX P $/kg $ 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 3 0 0.0 0 0.0 0 0.0 3 0 0.0 0 0 0.0 0 0.0 0 0.0 3 0 - 0.0 3 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 1 2 3 4 1 2 3 4 4.3.2 Digital tare Subtraction 1 - ZERO OPERATION 2 - NET 3 - FIX T KEYS PT kg Stand-by-status. 4 - FIX P Kg $/kg $ 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Key in the tare weight (e.g 5g). [5] 0.0 0 0 0.0 0 0 0.0 5 0.0 0 Subtract the tare weight (Assume 15kg). [T] 0.0 0 5 - 0.0 0 5 0.0 0 0.0 0 Clear the tare weight. [T] 0.0 0 0 0.0 0 0.0 0 85 0.0 0 0 SM 110 REGISTRATION MODE 4.4 PLU Call Up There are three ways to cal up programmed PLU: z Manual PLU Call Up z By press assigns to the preset key that desired PLU. z Auto PLU Call Up. Note: The machine beeps if incorrect operation is performed when during PLU calls up. z call Non-Weighed PLU up when something is on the platter. z Non-PLU with the entered number exists. z PLU Preset Key not set. 4.4.1 Manual PLU Call Up Manual PLU Call up is by enter the PLU Number by numeric Keys and then follow by pressing [PLU] key on Keypad. OPERATION 1 - ZERO PT kg KEYS Stand-by-status Enter the PLU No. of the Beef steak.(Ex.No.10) [0] [1] [0] Kg 2 - NET $/kg 3 - FIX T $ 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 1.00 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Clear the PLU and return to Stand-by-status. [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 1 4 - FIX P 2 3 4 4.4.2 PLU Call Up by Preset Key To enable this function, the PLU must assign on the Preset Key in advance. OPERATION 1 - ZERO PT Kg kg KEYS Stand-by-status Press the Preset key where desired PLU is 2 - NET $/kg 3 - FIX T $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 [P1] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2 4 - FIX P 3 4 assigned. Clear the PLU and return to Stand-by-status. 4.4.3 PLU Call by Numeric Key (Auto PLU Call) There are two type of Auto PLU Call, by enter the Specification Digits of the PLU Number or by TIME-OUT is depending on Spec Setting.(Spec39 and Spec40) 86 SM 110 REGISTRATION MODE OPERATION 1 - ZERO PT Kg kg KEYS Stand-by-status Enter the PLU No. of the Beef steak [0] [1] [0] 2 - NET $/kg 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0 0.0 0 0 0.1 0 3 - FIX T $ 1 2 4 - FIX P 3 4 0.0 0 0.0 0 BEEF STEAK Clear the PLU and return to Stand-by-status. [C] 0.0 0 0 0.0 0 0 1.20 0.00 0.0 0 0 0.0 0 0 0.0 0 0.0 0 4.5 Fix Operation 4.5.1 Fix Tare by FIX Key 1 - ZERO 2 - NET KEYS OPERATION 3 - FIX T PT kg Kg 4 - FIX P $/kg $ Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Put tare (e.g 30 g) on platter. 0.0 0 0 0.0 3 0 0.0 0 0.0 0 Subtract the tare weight. [T] 0.0 3 0 0.0 0 0 0.0 0 0.0 0 Fix tare. [FIX] 0.0 3 0 0.0 0 0 0.0 0 0.0 0 Cancel fix tare by FIX key. [FIX] Add tare (e.g 10 g) on platter. 0.0 3 0 0.0 0 0 0.0 0 0.0 0 0.0 3 0 0.0 1 0 0.0 0 0.0 0 Subtract the tare weight. [T] 0.0 4 0 0.0 0 0 0.0 0 0.0 0 Fix tare. [FIX] 0.0 4 0 0.0 0 0 0.0 0 0.0 0 Remove the tare weight. 0.0 4 0 - 0.0 4 0 0.0 0 0.0 0 Key in the tare weight (e.g 50g). [5] [0] 0.0 4 0 - 0.0 4 0 0.5 0 0.0 0 Set new tare and cancel fix tare by T key. [T] 0.0 5 0 - 0.0 5 0 0.0 0 0.0 0 Fix tare. [FIX] 0.0 5 0 - 0.0 5 0 0.0 0 0.0 0 Clear the tare weight and fix tare. [T] 0.0 0 0 0.0 0 0.0 0 0.0 0 0 1 2 3 4 1 2 3 4 4.5.2 Fix PLU by FIX Key 1 - ZERO 2 - NET KEYS OPERATION 3 - FIX T PT kg Stand-by-status. Kg 4 - FIX P $/kg $ 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Enter the PLU No. of the Beef steak [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Fix PLU. [FIX] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Cancel fix PLU by FIX key. [FIX] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Enter the PLU No. of the Beef steak [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Fix PLU. [FIX] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 Enter the PLU No. of the Roast Beef. [2] [0] 0.0 0 0 0.0 0 0 0.2 0 0.0 0 Call up PLU and cancel fix P. [PLU] 0.0 0 0 0.0 0 0 2.4 0 0.0 0 Fix PLU [FIX] 0.0 0 0 0.0 0 0 2.4 0 0.0 0 Clear PLU and fix PLU. [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 87 SM 110 REGISTRATION MODE 4.5.3 Fix Unit Price by FIX Key 1 - ZERO 2 - NET KEYS OPERATION 3 - FIX T PT kg Stand-by-status. Kg 4 - FIX P $/kg $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Enter unit price. [1] [0] [0] 0.0 0 0 0.0 0 0 1.0 0 0.0 0 Fix unit price. [FIX] 0.0 0 0 0.0 0 0 1.0 0 0.0 0 Cancel fix unit price. [FIX] 0.0 0 0 0.0 0 0 1.0 0 0.0 0 Enter unit price. [2] [0] [0] 0.0 0 0 0.0 0 0 2.0 0 0.0 0 Fix unit price. [FIX] 0.0 0 0 0.0 0 0 2.0 0 0.0 0 Clear unit price and fix unit price. [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2 3 4 4.6 Operation Mode Change 1 - ZERO - NET OPERATION 3 - PREPACK KEYS Receipt mode. PT kg 0.0 0 0 Depress [MODE] key while depressing [REZERO] [REZERO] key. [REZERO]+[MODE] Set to label manual mode. [REZERO] [REZERO] key. [REZERO]+[MODE] Kg 0.0 0 0 0.0 0 0 $/kg 0.0 0 $ 1 0.0 0 LABEL MODE 0.0 0 0.0 0 8888 88888 888888 8888888 RECEIPT MODE 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 88 2 5 - LABEL 8888 88888 888888 8888888 0.0 0 0 Depress [MODE] key while depressing Set to receipt mode. 4 - MANUAL 2 3 4 5 SM 110 REGISTRATION MODE 4.7 Item Label Printing in Manual Mode You can use this operation to print out item labels for a PLU or Non-PLU of Weighing Item or Non-weighing Item. Before the operation, check the following point. Press [REZERO] and [MODE] to select LABEL mode. Check whether the Label Size fits the programmed one in PLUs when label is used. 4.7.1 Label Printing for PLU Item For example: Sell 1kg of BEEF STEAK(Ex. PLU #: 10) (Weighing Item). 1 - ZERO OPERATION KEYS 2 - NET 3 - FIX T PT Stand-by-status. kg Kg 4 - FIX P $/kg 5 - MANUAL $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Enter the PLU No. of the Beef steak. [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 0.0 0 0 1.0 0 0 1.2 0 1.2 0 Print out one item label. [*] 0.0 0 0 1.0 0 0 1.2 0 1.2 0 Remove the product from the platter. [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Place the product on the platter. (e.g. 1kg) 2 3 4 6 - LABEL 5 6 For example: Sell one pack of SMOKED SAUSAGE (Ex. PLU #: 30) and sell five packs of SLICED BACON (Ex. PLU #: 40). (Non-weighing Item) 1 - ZERO OPERATION KEYS Stand-by-status. 2 - NET 3 - FIX T PT kg Kg 4 - FIX P $/kg 5 - MANUAL $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 0.3 0 0.0 0 2.5 0 PR-PCS Enter the PLU No. of the Smoked Sausage. [3] [0] Press PLU key. [PLU] Press [*] key to print label. [*] 0.0 0 0 0.0 0 0 0.0 0 1.2 0 Enter the PLU No. of the Sliced Bacon. [4] [0] 0.0 0 0 0.0 0 0 0.4 0 0.0 0 Press PLU key. [PLU] 3.2 0 PR-PCS Multiply. [X] QTY 1 3.2 0 3.2 0 5 packs. [5] QTY 5 3.2 0 1 6.0 0 Print out one item label. [*] 0.0 0 0 0.0 0 0.0 0 0.0 0 0 89 2 3 4 6 - LABEL 5 6 SM 110 REGISTRATION MODE 4.7.2 Label Printing for NON-PLU Item It is possible to print item label for Non-PLU Item at Manual Mode. The Non-PLU Item will be cleared is a PLU is called up or [C] key is pressed. Note: For Weighing of Non-PLU Item will be registered to PLU # 999998. For Non-weight of Non-PLU item, will be registered to PLU # 999999. For example: Enter the Price for Non-PLU item (Ex. 5.00) by numeric key. Note: For Non-weight Item, just press [*] key to issue out a label or press [X] key to enter multiply mode, then enter sale quantity and press [*] key to issue label. 1 - ZERO 3 - FIX T 4 - FIX P OPERATION KEYS Stand-by-status. Enter the unit price [5] [0] [0] Multiply. [X] 5 packs. [5] Print out one item label. [*] 5 - MANUAL PT kg Kg $/kg $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 5.0 0 0.0 0 QTY 1 5.00 5.00 QTY 5 5.0 0 25.0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 90 2 - NET 6 - LABEL 2 3 4 5 6 SM 110 REGISTRATION MODE 4.8 Total Label Printing in Manual Mode This operation is used for printing total label in Manual Mode. 4.8.1 Sales Transaction This section shows how to operate the transactions with Clerk key. The designated Clerk key accumulates each transaction data and Total Label will be issued. For example: Sells 1.5 kg of HERB CHEESE(Ex. PLU #: 3) and 2 packs of SKIM MILK(Ex. PLU # 302) for customer A. 1 - ZERO OPERATION KEYS Stand-by-status. Enter the PLU No. of the HERB CHEESE [3][PLU] Place the product on the platter. (1.5kg) Register sales item to Vender1. PT kg Kg [X][2] Register sales item to Vender1. [V1] Print out one total label. [*] $/kg 4 - V2 $ 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 5.0 0 0.0 0 0.0 0 0 1.5 0 0 5.0 0 7.5 0 -V1- TOTAL 1PCS 7.5 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 [3][0][2][PLU] Enter the sell Qty (Ex. 2 packs) 3 - V1 0.0 0 0 [V1] [C] Enter the PLU No. of the SKIM MILK 2 - NET 3.0 0 PR-PCS QTY 2 3.0 0 6.0 0 -V1- TOTAL 3PCS 13.5 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 91 5 - V3 1 2 3 6 - V4 4 5 6 SM 110 REGISTRATION MODE 4.8.2 [PRICE DISCOUNT] Function Key in Add Mode This function key is used to get the desirable discounted total price in Add. Mode by subtracting the discount value from the original total price when issuing total label or receipt. The formula is shown as follows PRICE TO PAY = ORIGINAL TOTAL PRICE - ENTERED DISCOUNT VALUE Note: Prior to this operation, [PRICE DISCOUNT] Function should be assigned to Preset Key in advance (Ex. Assign to Preset Key No.2). OPERATION KEYS 1 - ZERO PT kg Stand-by-status. 2 - NET Kg 3 - V1 $/kg $ 4 - V2 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Enter the PLU No. of the Beef steak. [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.20 0.0 0 0.0 0 0 1.0 0 0 1.20 1.2 0 1PCS 1.2 0 Place the product on the platter. (e.g. 1kg) Register sales item to Vender1. [V1] -V1- TOTAL Press [P2] key. [P2] -V1- DISC 0.00 Enter discount value. (Ex.$0.20) [2] [0] -V1- DISC 0.20 Confirm. [*] -V1- TOTAL 1PCS 1.00 [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2 5 - V3 3 4 5 6 - V4 6 4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode This function key is used to get the desirable discounted total price in Add Mode by setting the discount % value from the original total price when issuing total label or receipt. The formula is shown as follows PRICE TO PAY = ORIGINAL TOTAL PRICE x (100% - DISCOUNT % VALUE) Note: Prior to this operation, [PRICE % DISCOUNT] Function should be assigned to Preset Key in advance (Ex. Assign to Preset Key No.3). 1 - ZERO OPERATION KEYS Stand-by-status. 2 - NET PT kg 0.0 0 0 Kg 3 - V1 $/kg 0.0 0 0 0.0 0 4 - V2 $ 0.0 0 Enter the PLU No. of the Beef steak. [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0 Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.20 0.0 0 0.0 0 0 1.0 0 0 1.20 1.2 0 -V1- TOTAL 1PCS 1.2 0 Place the product on the platter. (e.g. 1kg) Register sales item to Vender1. [V1] Press [P3] key. [P1] -V1- DISC RATE 0.00 Enter discount rate. (Ex.10%) [1] [0] [0] [0] -V1- DISC RATE 10.00 Confirm. [*] -V1- TOTAL 1PCS 1.08 [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 92 5 - V3 1 2 3 6 - V4 4 5 6 SM 110 REGISTRATION MODE 4.9 Data Correction The data correction during accumulating operation is to correct sales transaction data when customer canceled the purchases or operators make a mistake before issuing Total Label or Receipt. The corrected item data is printed with two lines crossed on the Total Receipt. SM-100 has 2 correcting functions as follows: 1) On-the-spot Correction Is to void the last item data during accumulating operation. 2) Void by Item Correction Is to void sales data by tracing transaction number during accumulating operation. 4.9.1 On The Spot Correction This function is to void the last item data of an accumulating operation, when an operator noticed it was a mistake or a customer canceled purchase before issuing a Receipt or Total Label. It is effective for either weighed or non-weighted item in the last transaction. Transaction Example Vender 1: (1) 1kg of BEEF STEAK. (2) One pack of Smoked Sausage. (3) More 5kg of BEEF STEAK. But customer canceled 5kg of BEEF STEAK accumulated in the last operation. 1 - ZERO OPERATION KEYS Stand-by-status. Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] Place the product on the platter. (e.g. 1kg) Register sales item to Vender1 [V1] Remove the product from the platter. 2 - NET PT kg Kg Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] Place the product on the platter. (e.g. 5kg) $ 0.0 0 0 0.0 0 0.0 0 0.0 0 0 1.2 0 0.0 0 0.0 0 0 1.0 0 0 1.2 0 1.2 0 -V1- TOTAL 1PCS 1.2 0 0.0 0 0 -V1- TOTAL 0.0 0 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2.5 0 PR-PCS 2PCS 3.7 0 1.2 0 0.0 0 5.0 0 0 1.2 0 6.0 0 Register sales item to Vender1 [V1] -V1- TOTAL 3PCS 9.7 0 Delete the last item entry. [-] -V1- TOTAL 2PCS 3.7 0 0.0 0 0.0 0 [C] 0.0 0 0 93 0.0 0 0 5 - V3 1 0.0 0 0 0.0 0 0 [V1] $/kg 4 - V2 0.0 0 0 Enter the PLU No. of the Smoked Sausage. [3] [0] [PLU] Register sales item to Vender1 3 - V1 2 3 6 - V4 4 5 6 SM 110 REGISTRATION MODE 4.9.2 Void by Item Correction This function is to void the specified transaction during an accumulating operation. Operator can designate the number of transaction to be voided even if plural transactions for the same item are performed. Transaction example Vender 1: (1) 1kg of BEEF STEAK. (2) One pack of Smoked Sausage. (3) More 5kg of BEEF STEAK. But customer canceled One pack of Smoked Sausage in the 2nd transaction. OPERATION 1 - ZERO 2 - NET KEYS PT kg Stand-by-status. Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] Place the product on the platter. (e.g. 1kg) Register sales item to Vender1 [V1] Remove the product from the platter. [C] Enter the PLU No. of the Smoked Sausage. [3] [0] [PLU] Register sales item to Vender1 [V1] Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] Kg 4 - V2 $/kg $ 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 1.2 0 0.0 0 0.0 0 0 1.0 0 0 1.2 0 1.2 0 -V1- TOTAL 1PCS 1.2 0 0.0 0 0 0.0 0 0.0 0 -V1- TOTAL 2PCS 3.7 0 0.0 0 0 2.5 0 PR-PCS Place the product on the platter. (e.g. 5kg) Register sales item to Vender1 3 - V1 [V1] [C] 0.0 0 0 0.0 0 0 1.2 0 0.0 0 0.0 0 0 5.0 0 0 1.2 0 6.0 0 -V1- TOTAL 3PCS 9.7 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 Delete the selected item. [-] VD 1 1PCS 1.2 0 [<<] or [>>] to search the item. [>>] VD 2 1PCS 2.5 0 Delete the selected item. [*] Check Vender1 sale total. [V1] 0.0 0 0 [C] 0.0 0 0 0.0 0 0.0 0 -V1- TOTAL 2PCS 7.2 0 0.0 0 0.0 0 0.0 0 0 94 0.0 0 0 5 - V3 1 2 3 6 - V4 4 5 6 SM 110 REGISTRATION MODE 4.10 Item Label Printing in Pre-pack Mode Pre-pack Mode can be switched from Manual mode by pressing [AUTO] key. In this mode, the following functions are available, (1) For weighing item, label is automatically issued (without pressing [*] key) after the weight of the item gets stable. The machine keeps the PLU data until [C] key is pressed. (2) For non-weighing item, the next label is automatically issued (without pressing [*] key) after a label is taken away. The machine keeps the PLU data until [C] key is pressed. 4.10.1 Item Label Issue for PLU Item For example: To weighing (Ex. 1kg) 20 packs of FRIED POTATOES (Weighing Item, PLU #8) 1 - ZERO 2 - NET OPERATION KEYS Stand-by-status. PT 3 - FIX T 4 - FIX P kg $/kg Kg 5 - PREPACK $ 1 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Press [AUTO] key [AUTO] 0.0 0 0 0.0 0 0 0.0 0 0.0 0 Enter the PLU No. of the FRIED [8][PLU] 0.0 0 0 0.0 0 0 2.2 3 0.0 0 0.0 0 0 1.0 0 0 2.2 3 2.2 3 Remove the product from platter and take the 0.0 0 0 0.0 0 0 2.2 3 0.0 0 label off.. Repeat the above 3 and 4 step to weighing the next pack, until the last packed is weighed. 0.0 0 0 0.0 0 0 0.0 0 0.0 0 2 6 - LABEL 3 4 5 6 3 6 - LABEL 4 5 6 POTATOES (Ex. PLU#8). Place the product on the platter. (e.g. 1kg) (The label automatically issued) For example: issue 20 labels of SMOKED SAUSAGE (Non-Weighing Item, PLU #30). 1 - ZERO 2 - NET 3 - FIX T KEYS PT kg Kg OPERATION Stand-by-status. 0.0 0 0 0.0 0 0 4 - FIX P $/kg 0.0 0 $ 5 - MANUAL 1 2 0.0 0 Enter the PLU No. of the Smoked Sausage. [3] [0] [PLU] Prepare to issue label for non-weighing item. [*] LABEL NUMBER 1 Enter number of labels to be printed, e.g. 20 [2][0] LABEL NUMBER 20 Print out the first label… [*] LABEL COUNT 20 LABEL COUNT 19 LABEL COUNT 1 0.0 0 0 0.0 0 0.0 0 Print out the second label… 2.5 0 PR-PCS *Note …… Print out the last label. Stand-by-status. 0.0 0 0 Note1: To cancel printing, depress C key. 95 SM 110 REGISTRATION MODE 4.10.2 Item Label Issue for NON-PLU Item It is possible to print item label for Non-PLU Item at Pre-pack Mode. The Non-PLU Item will be cleared is a PLU is called up or [C] key is pressed. For example: At Pre-pack Mode, enter the Price for Non-PLU item (Ex. 5.00) by numeric key. 1 - ZERO 2 - NET KEYS PT OPERATION At Pre-pack Mode Enter the unit price(Ex.5.00) [5][0][0] Place the product on the platter. (e.g. 1kg) (The 3 - FIX T kg Kg 4 - FIX P $/kg $ 5 - PREPACK 1 2 3 0.0 0 0 0.0 0 0 0.0 0 0.0 0 0.0 0 0 0.0 0 0 5.0 0 0.0 0 0.0 0 0 1.0 0 0 5.0 0 5.0 0 0.0 0 0 0.0 0 0 2.2 3 0.0 0 0.0 0 0 0.0 0 0 0.0 0 0.0 0 label automatically issued) Remove the product from platter and take the label off.. [C] Note1: For Non-weight Item, just press [*] key to start issuing out a label and registered to PLU # 999999. Note2: For Weighing of Non-PLU Item will be registered to PLU # 999998. 96 6 - LABEL 4 5 6 SM 110 READ REPORT MODE 5. READ REPORT MODE 5.1 Report Factor Select Whether to use the following report print factors depends on the type of report. Please refer to Operation Flow in Report Mode. PRINT LIMIT For setting the report range, Department Number, Main Group Number or PLU Number to start and finish is to be entered. LOWER LIMIT: DEPARTMENT: No.1 - No.99 MAIN GROUP: No.1 - No.999 UPPER LIMIT: DEPARTMENT: No.1 - No.99 MAIN GROUP: No.1 - No.999 5.2 Report Type Selection There are two ways to select the Report Type by using different keys such as: • Preset keys that the desired Report Type is assigned to . • By press [X] or [《][》]key to select the Report Type . Enter Report Mode (“X” Mode) from Stand-by Status. OPERATION DISPLAY REMARK PT kg $/kg $ 0.000 0.000 0.00 0.00 Stand-by Status [MODE][MODE] X1.1 READ MG DAILY Enter X mode. [X] X2.1 READ PLU DAILY Press [X] key to select the Report Type. 97 SM 110 READ REPORT MODE 98 SM 110 READ REPORT MODE 5.2.1 Main Group Report Printing report order for MAIN GROUP Daily/Term Read Report: For example: • MAIN GROUP LOWER LIMIT: 3 • MAIN GROUP UPPER LIMIT: 996 OPERATION DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY [*] X1.1 1 ST NUM Enter starting M.G.(Ex.3) [3][*] X1.1 3 ED NUM Enter ending M.G.(Ex.996) - REPORT PRINTING - [9][9][6][*] Select M.G. Daily Read Report. Print M.G. daily Read Report X1.1 READ MGROUP DAILY Display back to X mode. [《] or [》] or [X] X1.4 READ MG TERM Select M.G. Term Read Report. [*] X1.4 1 ST NUM Enter starting M.G.(Ex.3) [3][*] X1.4 3 ED NUM Enter ending M.G.(Ex.996) - REPORT PRINTING - MG TERM [9][9][6][*] X1.4 READ 5.2.2 PLU Report Printing report order for PLU Daily/Term Read Report: For example: • PLU NUMBER LOWER LIMIT: 3 • PLU NUMBER UPPER LIMIT: 999996 99 Print M.G. Term Read Report. Display back to X mode. SM 110 OPERATION READ REPORT MODE DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X2.1 READ PLU DAILY Select PLU Daily Read Report. [*] X2.1 1 ST NUM Enter starting PLU Number.(Ex.3) [3][*] X2.1 3 ED NUM Enter ending PLU Number.(Ex.999996) - REPORT PRINTING - [9][9][9][9][9][6][*] Print PLU daily Read Report X2.1 READ PLU DAILY Display back to X mode. [《] or [》] or [X] X2.4 READ PLU TERM Select PLU Term Read Report. [*] X2.4 1 ST NUM [3][*] X2.4 3 ED NUM - REPORT PRINTING - PLU PERIOD [9][9][9][9][9][6][*] X2.4 READ Enter starting PLU Number.(Ex.3) Enter ending PLU Number. (Ex.999996) Print PLU Term Read Report t Display back to X mode. 5.2.3 Department Report Printing report order for DEPARTMENT Daily/Term Read Report: For example: • DEPARTMENT LOWER LIMIT: 3 • DEPARTMENT UPPER LIMIT: 96 OPERATION DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X3.1 READ DEPT DAILY Select Dept. Daily Read Report. [*] X3.1 1 ST NUM Enter starting Dept. Number.(Ex.3) [3][*] X3.1 3 ED NUM Enter ending Dept. Number.(Ex.96) - REPORT PRINTING - [9][6][*] OPERATION DISPLAY Print Dept. daily Read Report. REMARK PT kg $/kg $ X3.1 READ DEPT DAILY Display back to X mode. [《] or [》] or [X] X3.4 READ DEPT TERM Select Dept. Term Read Report. [*] X3.4 1 ST NUM Enter starting Dept. Number.(Ex.3) [3][*] X3.4 3 ED NUM Enter ending Dept. Number.(Ex.96) - REPORT PRINTING - DEPT TERM [9][6][*] X3.4 READ 100 Print Dept. Term Read Report. Display back to X mode. SM 110 READ REPORT MODE 5.2.4 Sales Report Printing report order for SALES Daily/Term Read Report: OPERATION DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X4.1 READ SALES DAILY Select Sales Daily Read Report. - REPORT PRINTING - Print Sales daily Read Report. [*] [《] or [》] or [X] X4.1 READ SALES DAILY Display back to X mode. X4.4 READ SALES TERM Select Sales Term Read Report. - REPORT PRINTING - Print Sales Term Read Report. DEPT TERM [*] X3.4 READ Display back to X mode. 5.2.5 24Hour Report On 24 Hour Report, Sales transaction data can be printed on 24-HOUR Daily/Term Read Report If you want to stop printing, press [FEED] key. OPERATION DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X5.1 READ 24 HOUR DAILY Select 24 HOUR Daily Read Report. - REPORT PRINTING - Print 24-HOUR Daily Read Report. [*] [《] or [》] or [X] X5.1 READ 24 HOUR DAILY Display back to X mode. X5.4 READ 24 HOUR TERM Select 24-HOUR Term Read Report. - REPORT PRINTING - Print 24-HOUR Term Read Report. 24 HOUR TERM [*] X5.4 READ Display back to X mode. 5.2.6 ABC Report ABC Report is used to check the sales situation of PLUs. The share of PLUs against total sales price are printed on ABC Analysis Report by descending order. The printed shares by descending order are divided into 3 ranks: A rank, B rank and C rank. 1) Rank A includes PLUs whose accumulated share is less than 75%. *Even if the accumulated share exceeds 75%, the last PLUs will be included in Rank A. 2) Rank B includes PLUs whose accumulated share is between 75% ~ 95%. *Even if the accumulated share exceeds 95%, the last PLUs will be included in Rank B. 101 SM 110 READ REPORT MODE 3) Rank C includes PLUs whose accumulated share is between 95% ~ 100%. *Even if the accumulated share exceeds 95%, the last PLUs will be included in Rank B. For example: Printing report order for ABC Daily/Term Read Report: • PLU NUMBER LOWER LIMIT: 1 • PLU NUMBER UPPER LIMIT: OPERATION 999 DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X6.1 READ ABC DAILY Select ABC Daily Read Report. [*] X6.1 1 ST NUM Enter starting PLU NO.(Ex.1) [1][*] X6.1 2 ED NUM Enter ending PLU NO.(Ex.999) - REPORT PRINTING - [9][9][9][*] Print ABC Daily Read Report. X6.1 READ ABC DAILY Display back to X mode. [《] or [》] or [X] X6.4 READ ABC TERM Select ABC Term Read Report. [*] X6.4 1 ST NUM Enter starting PLU NO.(Ex.1) [1][*] X6.4 1 ED NUM Enter ending PLU NO.(Ex.999) - REPORT PRINTING - ABC TERM [9][9][*] X6.4 READ Print ABC Term Read Report. Display back to X mode. 5.2.7 Clerk Report Clerk report is used to print out the total data such as total prices, total quantity and so on by every Clerk. For example: Printing report order for CLERK Daily Read Report: • CLERK NUMBER LOWER LIMIT: 1 • CLERK NUMBER UPPER LIMIT: OPERATION 4 DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY Lamp X turns on. [《] or [》] or [X] X7.1 READ CLERK DAILY Select Clerk Daily Read Report. [*] X7.1 1 ST NUM Enter starting CLERK NO.(Ex.1) [1][*] X7.1 1 ED NUM Enter ending CLERK NO.(Ex.4) - REPORT PRINTING - Print Vender Daily Read Report t CLERK DAILY [4][*] X7.1 READ 102 Display back to X mode. SM 110 READ REPORT MODE 5.2.8 Pre-pack Report On Pre-pack Report, Total data of Prepack labels (Such as total price, total quantity, etc) can be printed on PREPACK DEPARTMENT REPORT or PREPACK MAIN GROUP REPORT. For example: Printing report order for PREPACK DEPARTMENT/ MAIN GROUP REPORT: • DEPARTMENT LOWER LIMIT: 1 • DEPARTMENT UPPER LIMIT: 99 • MAIN GROUP LOWER LIMIT: 1 • MAIN GROUP UPPER LIMIT: OPERATION 999 DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY [《] or [》] or [X] X8.1 READ [*] X8.1 DEPT 1 ST NUM Enter starting Dept. Number.(Ex.1) [1][*] X8.1 DEPT 1 ED NUM Enter ending Dept. Number.(Ex.99) - REPORT PRINTING - [9][9][*] PPK DEPT PPK DAILY X8.1 READ [《] or [》] or [X] X8.2 READ PPK MG DAILY [*] X8.2 DEPT 1 ST NUM [1][*] X8.2 DEPT 1 ED NUM - REPORT PRINTING - PPK MG DAILY [9][9][9][*] X8.2 READ DEPT 103 DAILY Lamp X turns on. Select Pre-pack Department Daily Read Report. Print Pre-pack Department Daily Read Report. Display back to X mode. Select Pre-pack Main Group Daily Read Report. Enter starting Dept. Number.(Ex.1) Enter ending Dept. Number.(Ex.999) Print Pre-pack Main Group Daily Read Report Display back to X mode. SM 110 READ REPORT MODE 5.2.9 Tax Report Tax report is used to print out the Tax total data such as Tax Type, Tax rate, Amount Including Tax, Amount Excluding Tax, Tax Amount and so on by every Tax Number. OPERATION DISPLAY REMARK PT kg $/kg $ Enter X mode X1.1 READ MG DAILY [《] or [》] or [X] X9.4 READ TAX [*] X9.4 1 ST NUM Enter starting Tax Number.(Ex.1) [1][*] X9.4 1 ED NUM Enter ending Tax Number.(Ex.3) - REPORT PRINTING - READ TAX [3][*] X9.4 Lamp X turns on. Select Tax Daily Read Report. Print Tax daily Read Report. Display back to X mode. 5.2.10 Store Summarized Report OPERATION DISPLAY PT kg $/kg $ Enter X mode X1.1 READ MG DAILY [《] or [》] or [X] X4.3 READ STORE SUMMARY - REPORT PRINTING - STORE SUMMARY [*] X4.3 READ 104 REMARK Lamp X turns on. Select Store Summarized Daily Read Report. Print Store Summarized Daily Read Report. Display back to X mode. SM 110 RESET REPORT MODE 6. RESET REPORT MODE Reset Sales Daily / Monthly/Term Reset Report OPERATION DISPLAY PT kg $/kg $ Z1.0 RESET SALES DAILY [*] RESET REPORT ? Y-C N-T [C] Z1.0 RESET SALES DAILY [《] or [》] or [X] Z2.0 RESET SALES MONTHLY [*] RESET REPORT ? Y-C N-T [C] Z2.0 RESET SALES MONTHLY [《] or [》] or [X] Z3.0 RESET SALES TERM [*] RESET REPORT ? Y-C N-T [C] Z3.0 RESET SALES TERM Enter Z mode 105 REMARK Lamp Z turns on. Enter Reset mode. [C] for Yes,[T] for No. Display back to Z mode. Select Sales Monthly Reset Report. Enter Reset mode. [C] for Yes,[T] for No. Display back to Z mode. Select Sales Term Reset Report. Enter Reset mode. [C] for Yes,[T] for No. Display back to Z mode. Specification List TITLE REVISION NO. ISSUED DATE Rev. No. 0 SM-110 V1.20 : : : 20 December, 2005 SM-110 SPECIFICATION LIST 0 17 August, 2004 Modification Details First Release 1 Software Version 1.00 Specification List SPEC NO. SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 CUSTOMER SPECIFICATION [REZERO] + [1][4][1] 00 01 02 Item Barcode 0 F1F2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 2 F1F2 CCCCC 0 XXXX CD 3 F1F2 CCCCCC XXXX CD 4 F1F2 CCCCC XXXXX CD 5 F2 CCCCCC XXXXX CD 6 F2 CCCCC XXXXXX CD 7 F1F2 CCCCCCCCCC CD #1 8 F1F2 CCCC XXXXXX CD 9 F1F2 CCCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode 12 F1X2 CCCCC XCD XXXX CD 9 13 14 15 16 17 18 19 20 F1X2 CCCCCC XXXX CD F1F2 CCCC XCD XXXXX CD F2 CCCCC XCD XXXXX CD F1F2 CCC XXXXXXX CD F1F2 CC XXXXXXXX CD CCC WWWW PPPPP CD No Barcode F1F2 CCCCC PCD XXXX CD Right Side Data of Item Barcode 0 Quantity 1 Price 2 Weight 3 User Programmable # 4 5 6 7 Original Price Weight / Quantity Unit Price Unit Price after discount Right Side Price Data of Item Barcode 0 Price before Tax 1 Price after Tax All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode 9 # Related to SPEC153. 9 Effective when SPEC1 = 1 03 Flag Data F1 and F2 for 13 Digits Non-PLU Barcode Enter value from range 0 to 99 9 04 Flag Data F1 and F2 for 13 Digits PLU Barcode Enter value from range 0 to 99 9 05 Flag Data F2 for 8 Digit Non-PLU Barcode Enter value from range 0 to 9 9 06 Flag Data F1 and F2 for 8 Digit PLU Barcode Enter value from range 0 to 99 9 07 Total Barcode 0 F1F2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 2 F1F2 CCCCC 0 XXXX CD 3 F1F2 CCCCCC XXXX CD 4 F1F2 CCCCC XXXXX CD 5 F2 CCCCCC XXXXX CD 6 F2 CCCCC XXXXXX CD 7 F1F2 CCCCCCCCCC CD #1 8 F1F2 CCCC XXXXXX CD 9 F1F2 CCCC CD #2 10 F2 CC XXXX CD #3 11 No Barcode 08 Left Side Data of Total Label 0 Scale No. 1 Last Accumulated Item Code 2 Receipt No. 9 12 13 14 15 16 17 18 19 20 F1X2 CCCCC XCD XXXX CD F1X2 CCCCCC XXXX CD F1F2 CCCC XCD XXXXX CD F2 CCCCC XCD XXXXX CD F1F2 CCC XXXXXXX CD F1F2 CC XXXXXXXX CD CCC WWWW PPPPP CD No Barcode F1F2 CCCC PCD XXXX CD 3 4 Clerk No. Fixed No. All are 13 digits non-PLU barcode unless otherwise stated. #1 13 digits PLU barcode #2 8 digits PLU barcode #3 8 digits non-PLU barcode 9 09 Fixed Data for Left Side Data of Total Barcode Enter value from range 0 to 9 999 999 999 9 10 Flag Data F0, F1 and F2 for Total Barcode Enter value from range 0 to 999 9 2 Specification List SPEC NO. 11 12 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Right Side Data of Total Barcode 0 Quantity 1 Price Total Barcode Print on Receipt 0 No SM-100 9 2 Weight 1 Yes 9 13 Print Readable Character of F1 for Item and Total Barcode (for EAN only) 0 No Print 1 Print 8 14 Printing Position for Advertisement Message 0 First Line 2 1 Below 3 9 Above Not Used 15 Turnover Printing for Advertisement Message 0 No 1 Yes 16 Exit from “Change” Mode within Specified Interval 0 No 3 10 sec 1 3 sec 4 15 sec 2 6 sec 9 17 Order of the Month, Day and Year for Print 0 MM/DD/YY 2 1 DD/MM/YY 3 9 18 19 20 YY/MM/DD Not Used 9 1 or 2 Line(s) Commodity Name on Receipt 0 2 Lines 2 1 1 Line No Print Label Printing by Clerk Key 0 No Print 1 Print with Accumulation 2 Print without Accumulated 1 Print Total Label Printing 0 No Print 9 9 21 Printing Operator Name on Receipt and Label 0 Code 1 Name 9 22 Receipt Paper Width 0 60 mm 1 40 mm 8 2 50 mm 23 Manual Price Entry for Printing or Accumulating 0 Allow 1 Inhibit 24 Default Label Format for Item Printing 0 T1 (A) 1 T2 (B) 2 T3 (C) 3 T4 (U2) 4 T5 (U3) 5 T6 (U4) 6 T7 (U5) 7 T8 (U6) 8 T9 (U7) 9 T10 (U8) 10 T11 (T5) 11 T12 (T6) 9 9 12 13 14 15 16 17 18 19 20 21 22 23 S A B C F1 F2 F3 F4 F5 F6 F7 F8 3 (T7) (T8) (T9) (T10) (F1) (F2) (F3) (F4) (F5) (F6) (F7) (F8) Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format. Specification List SPEC NO. 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION 9 Default Label Format for Total Printing 0 T1 (A) 1 T2 (B) 2 T3 (C) 3 T4 (U2) 4 T5 (U3) 5 T6 (U4) 6 T7 (U5) 7 T8 (U6) 8 T9 (U7) 9 T10 (U8) 10 T11 (T5) 11 T12 (T6) 12 13 14 15 16 17 18 19 20 21 22 23 S A B C F1 F2 F3 F4 F5 F6 F7 F8 Shop Name Printing on Label 0 No Print 1 Print Forced Tare Function 0 Disable 1 Enable Peel Sensor Function in Prepack Mode 0 Disable 1 Enable (T7) (T8) (T9) (T10) (F1) (F2) (F3) (F4) (F5) (F6) (F7) (F8) Formats in ( ) are for U1 and CA only. F1 to F8 are Free Format. 9 9 9 9 Continuous Print for Label in Prepack Mode 0 Inhibit 1 Allow Selection of CDV 0 Inhibit 1 Allow CDV Type 0 CDV 1 Tear-off CDV Modulus 0 Modulus 10 1 Modulus 11 On Spot Correction 0 Allow 1 Inhibit Search Correction 0 Allow 1 Inhibit Move Back Correction 0 Allow 1 Inhibit Past Sales Data Correction 0 Allow 1 Inhibit Label Print Density 0 Low 1 Mid 2 3 High-mid High Receipt Print Density 0 Low 1 Mid 2 3 High-mid High 2 Time-out Calling of PLU 0 Manual 1 Auto SM-100 8 For SF only. 8 For SF only. 8 For SF only. Effective when SPEC30 and 31 = 1. 9 8 9 9 9 9 PLU Digits for Auto PLU Calling/Time-out Calling 0 3 Digits / 0.5 sec 2 5 Digits / 1.5 sec 1 4 Digits / 1.0 sec 3 6 Digits / 2.0 sec 4 Related to SPEC40. 9 Effective when SPEC39 = 1. Specification List SPEC NO. 41 42 43 44 45 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa 0 Allow 1 Inhibit 9 Unit Price Override 0 Allow 9 1 Effective when SPEC643 = 1. Inhibit Main Usage for Commodity Name, Shop Name and Special Message 0 Receipt 1 Label 9 Tare Override 0 Allow 9 1 Inhibit Item Printing 0 Allow 1 Inhibit Always set to 0 for SM200. 9 46 Default Data of Printing Shop Name Number for Label Enter value from range 0 to 32 9 47 Default Data of Printing Shop Name Number for Receipt Enter value from range 0 to 32 9 48 Setting of Scale Number Enter value from range 0 to 999 999 9 49 Type of Client / Server Interface 0 No Interface 1 Ethernet (Coaxial Cable) 2 Ethernet (Twisted Pairs) 3 4 Not Used 4-Lines (RS-485) Setting of Client / Server 0 Client 1 Server / Workstation 2 Backup Server Baud Rate of SIO (RS-232C Port) 0 1 200 bps 1 2 400 bps 2 4 800 bps 3 9 600 bps 4 5 6 19 200 bps 38 400 bps 76 800 bps 1 8 Bits 2 Even 1 2 Bits 50 51 52 53 54 55 56 Data Length of SIO (RS-232C Port) 0 7 Bits Parity Bit of SIO (RS-232C Port) 0 None 1 Odd Stop Bit of SIO (RS-232C Port) 0 1 Bit 9 Related SPECs for Ethernet I/F are SPEC50, 135, 214. 9 Related SPECs for S/C setting are SPEC61, 150, 163, 165, 187, 194, 208, 229, 252, 253, 254, 255, 265, 276. 9 Apply to both RS-232C and RS-485 ports setting for SM-300. Related SPECs are SPEC48, 52, 53, 54, 60, 134. 9 Apply to both RS-232C and RS-485 ports setting for SM-300. 9 Apply to both RS-232C and RS-485 ports setting for SM-300. 9 Apply to both RS-232C and RS-485 ports setting for SM-300. Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 200 bos 3 9 600 bps 1 2 400 bps 4 19 200 bps 2 4 800 bps 5 38 400 bps 8 Data Length of Multi-drop SIO (RS-485 / 4-Lines Port) 0 7 Bits 1 8 Bits 8 5 Related SPECS are SPEC48, 56, 57, 58, 59, 134. Specification List SPEC NO. SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 57 Parity Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 None 2 Even 1 Odd 8 58 Stop Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 0 1 Bit 1 2 Bits 8 59 Multi-drop SIO (RS-485 / 4-Lines Port) Select Job 0 No Operation 2 Pick ‘N’ Pay #2 1 FIS 3000 #1 8 SIO (RS-232C Port) Select Job 0 No Operation 1 FIS 30000 #1 2 FL-1 8 3 4 5 Point ‘N’ Shop Barcode Scanning Video Control #2 Floating Clerk 0 Inhibit 1 Allow Receipt Free Format 0 Disable 1 Enable 60 61 62 63 64 8 Exclude AA. 8 Yes 9 2 Allow Multi Password 65 Report Printing in Daily and Term Transaction Clear 0 Inhibit 1 Allow 66 Pack Quantity Function Key Enable 0 Allow 1 Inhibit Advertisement Function Key Enable 0 Allow 1 Inhibit 67 Apply for both RS-232C and RS-485 ports setting for SM-300. #1 Refer to SPEC59’s comments #1. #2 For SM-300 only 8 SM-90 and DI-10 RS-232C Communication 0 No 1 Enable Password Mode 0 Allow 1 Inhibit #1 Either SPEC59 or 60 can be selected at any one time. #2 For SF only. 9 9 68 Fixed Total Price Discount Function Key Enable 0 Allow 1 Inhibit 9 69 Total Price Percentage Discount Function Key Enable 0 Allow 1 Inhibit 9 70 Fixed Unit Price Function Key Enable 0 Allow 9 1 Inhibit 71 Fixed Unit Price Percentage Function Key Enable 0 Allow 1 Inhibit 9 72 Pack Date Function Key Enable 0 Allow 9 1 Inhibit Minus Pack Date Function Key Enable 0 Allow 1 Inhibit Sell by Date Function Key Enable 0 Allow 1 Inhibit Unit Symbol Function Key Enable 0 Allow 1 Inhibit 73 74 75 9 9 6 Specification List SPEC NO. 76 77 78 79 80 81 82 83 84 85 SM-110 V1.20 SPECIFICATION DESCRIPTION Quantity Set Function Key Enable 0 Allow 1 Inhibit Price Change Function Key Enable 0 Allow 1 Inhibit Refund Item Function Key Enable 0 Allow 1 Inhibit Shop Name Function Key Enable 0 Allow 1 Inhibit Logo Function Key Enable 0 Allow 1 Inhibit Print Select Function Key Enable 0 Allow 1 Inhibit Print of Place of Production on Label 0 Inhibit 1 Allow Selection of Markdown 0 No Markdown 1 Unit Price Markdown 2 3 Total Price Markdown Unit and Total Price Markdown Sub-total Function Key Enable 0 Allow 1 Inhibit Grand Total Function Key Enable 0 Allow 1 Inhibit 9 9 9 9 8 Label Sensor Gap Value Enter value range from 0 to 255 87 Label Type 0 Gap 1 No Gap Sell by Date Title Print out 0 Inhibit 1 Allow ASCII Code Entry in S Mode 0 Inhibit 1 Allow Sub-total Markdown 0 No Markdown 1 Markdown 2 High 2 High 2 Not Used 3 4 3 sec Delay User Select 1 After Price 89 90 91 92 93 94 Printer Speed for Receipt 0 Slow 1 Normal Printer Speed for Label 0 Slow 1 Normal Printer Strode 0 Single 1 Double Print Second Receipt 0 No Print 1 Continuous Print 2 1 sec Delay Position of Currency Symbol (on Label) 0 Before Price SM-100 9 86 88 20 December, 2005 9 8 For AA only. 8 For AA only. 9 9 9 8 9 9 7 Specification List SPEC NO. 95 96 97 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 8 Receipt Printing with Dual Copy 0 Inhibit 1 Allow Advertisement Message on All Label 0 Inhibit 1 Allow 9 Manual Print in Prepack Mode for Weigh Item 0 Inhibit 1 9 Allow 98 Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode 0 Allow 1 Inhibit 9 99 Unit Print Out for Non-weigh Item in Manual Mode 0 Inhibit 1 Allow 8 100 Discount in PLU Programming 0 Allow 8 1 Inhibit Zero Suppress for Date and Time 0 Disable 1 Enable 1 Original Unit Price and Price 101 102 103 104 Discount Presentation in Receipt 0 Discounted Unit Price and Original Price 9 8 Unit Price Assignment Function Key for PLU 0 Enable 1 Discount Price Rounding Method 0 Rounding 1 Cut Down Disable 9 2 Cut Up 105 Fixed Total Price Markdown Function Key Enable 0 Allow 1 Inhibit 9 106 Total Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 9 107 Fixed Unit Price Markdown Function Key Enable 0 Allow 1 Inhibit 9 108 Fixed Unit Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 9 109 Source of Sell by Date 0 Real Time Clock 9 1 Packed Date Year Type 0 Standard 1 Japanese / Taiwan 2 Yen 110 111 Price Symbol on Receipt 0 No Print 1 Kanji Yen 8 For AA and TW only. 8 For AA only. 112 Default Data of Printing Special Message Number for Receipt Enter value range from 0 to 16 9 113 Label Logo Printing Status 0 No Print 1 Logo 1 2 Logo 2 9 3 4 Logo 3 Logo 4 8 Specification List SPEC NO. 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Receipt Logo Printing Status 0 No Print 1 Logo 1 2 Logo 2 3 Logo 1 and 2 4 5 6 SM-100 Logo 3 Logo 4 Logo 1, 2, 3 and 4 Type of Entry for Used by Date and Sell by Date 0 By Day 1 By Hour 8 Barcode Printing in First Label for Dual Label Printout 0 Print 1 No Print 8 Zero Minutes Printing 0 No Print 8 1 Print Both Price before and after Discount 0 Price before and after Discount 1 Price before Discount only 2 No Print PLU Number Print 0 No Zero Suppress 1 Zero Suppress Thick Japanese Character Printout 0 Thick Character 1 Thin Character Prepare Mode after Power On 0 Manual Mode 1 Prepack Mode Unit Symbol Printout in Receipt 0 Depend on PLU Programming 1 Japanese PCS For NICHII only. For NICHII only. 9 For AA only. 9 8 For AA only. 8 Always set to 0 for SM200. 8 Disable PLU Unit Price after Discount 0 Unit Price after Discount 1 Unit Price Discount Amount Position of Special Message on Receipt 0 Bottom 1 Top 9 9 Function Keys Protection for Self-service 0 No Protection 2 1 Full Protection 1 8 Partial Protection Enable 8 Setting of Host Number (For SM-15 Multi-drop) Enter value between 0 to 99 Type of Host to be Communicated 0 Standalone 1 TMR ECR For NICHII only. 8 Printing Thank You Message on Receipt 0 Enable 1 Printing of Checksum for Item Barcode 0 Disable For NICHII only. For IR only. 8 2 POS ECR For IR only. Use with SPEC128. 130 Selection of Print Item on Prepack Total Label 0 Based on Status on Item Label 1 Based on Status on Manual Total Label 9 131 Print PLU Setting Quantity in Manual Mode 0 No 1 9 Yes Receipt Total Report 0 No Yes 132 1 9 Effective when SPEC98 = 0. 8 For DM only. Specification List SPEC NO. SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 133 Change All PLU Default Format when Default SPEC Change 0 Yes 1 No 8 134 Host Communication 0 No Operation Host Communication 0 RS-232C 8 1 Enable 1 RS-485 9 135 Port Number Enter value from range 1 to 254 136 One or Two Touch for Self-service Operation 0 One Touch 1 Two Touches Centering of Ingredient Data 0 Yes No 137 9 9 1 138 Permanent Price or Discount Price Change via Function Key 0 No Update to PLU 1 Update to PLU 9 139 Number of Digits for Teraoka Code 0 2 Digits 8 1 3 Digits AA Message Size 0 24 x 24 1 16 x 16 Year Format 0 YY 1 YYYY 140 141 142 143 144 145 146 147 148 149 150 8 For AA only. 9 9 Selection of Day Display for Sell by Date 0 Disable 1 Enable Peel Sensor Trigger Voltage 0 High 1 Low Display Prepack Quantity Balance 0 Enable 1 Disable Print Select Function Across the Board 0 Disable 1 Enable Label Format 1, 2 Function Key Enable 0 Inhibit 1 Allow Exclude AA. Prepack Non-add Function Key Enable 0 Inhibit 1 Allow Exclude AA. FIS3000 Code 0 SM-80/90 FIS3D 1 SM-25 FIS3D Main Group Function Key Enable 0 Inhibit 1 Allow Preset Key Assignment for Client 0 Local Assign 1 Central Assign 8 8 8 151 Change Sell by Date or Used by Date when Packed Date Changed 0 No 1 Yes 152 Sell by Date or Sell by Time for Individual PLU 0 Disable 1 Enable 153 User Programmable Right Side Data for Item Barcode 0 With Identification Digit 1 Without Identification Digit 10 Exclude AA. Specification List SPEC NO. 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 8 Keysheet Letter Size 0 Small Letter 1 Capital Letter Test Print on Receipt 0 No Print 1 Print Image Copy from Free Format 0 Disable 1 Enable Training Mode 0 Disable 1 Enable FSD Price and Image 0 Disable 1 Enable ½ and ¼ Key Function 0 Disable 1 Enable Twisted Pair Cable for Ethernet 0 Shield 1 Unshielded Discount Label Format 0 Enable 1 Disable Item Code Function Key Enable 0 Enable 1 Disable Transaction Data Store in Client Memory 0 Disable 1 Enable Maximum Label Length 0 120 mm 240 mm For FL & AS only. 8 For SD only. 9 8 Exclude DEC. 8 For U1 only. 8 8 Not in used. 8 For SD only. 8 1 Update Report for Client / Server System 0 Yes 1 No Average Price and Weight Label Function 0 Disable 1 Enable Label Date Title Print 0 No Print 1 Print GB Code 0 GB Code 1 Shift GB Code Print PLU Setting Unit in Manual Mode 0 No 1 Yes 9 Exclude AA. 8 For CN and MS only. 170 User Specification (REZERO + 141) Accessible from Z Mode Only 0 No 1 Yes 8 171 Euro Mode 0 Disable 9 1 Enable Dual Declarations 0 No 1 Yes Mask 7-segment Display in X, S and Z Mode 0 No 1 Yes 172 173 174 8 For U1 only. 8 Fixed Clerk Assign to Preset Key 8, 16, 24 and 32 0 Clerk Keys 1 Function Keys 11 For double display types only. 8 For bench type only. Specification List SPEC NO. 175 176 177 178 179 180 181 182 183 184 SM-110 V1.20 SPECIFICATION DESCRIPTION 1 Enable Discount Time on Daily Basis 0 No 1 Yes Weight Check Function 0 No 1 Yes Unit Price Override per PLU 0 No 1 Yes Black Bar Sensing Label 0 Normal 1 Black Bar Sensing Scroll Message Group 0 Disable 1 Enable Continuos Label 0 Disable 1 Enable Character Size for Barcode Data 0 Large 1 Small PLU Clear after 10 seconds Time-out 0 No 1 Yes Duplicate Unit and Total Price on Label 0 No Print 1 Print 8 9 9 9 8 8 186 Print $ and Weight Unit on Label 0 No Print 1 Print Clear Total Data by Server 0 Both Server and Client 1 Server Tare Decimal Point Left Shift for SM-25 FIS3D 0 No 1 Yes 189 PLU Auto Delete 0 No Delete 1 15 Days 2 3 30 Days 90 Days Swap Weight and Unit Price on Receipt 0 No 1 Yes Default Item Code Equals to PLU Number 0 No 1 Yes Nutrition Template 0 Standard 1 Simplified 2 Simplified Condensed Standard Condensed Tabulated Tabulated Extra Condensed 192 193 194 Effective when SPEC158 = 1. 9 188 191 For UK only. 9 Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable 0 Disable 1 Enable 190 SM-100 8 30 lb to 15 kg Conversion 0 Disable 185 187 20 December, 2005 8 8 9 8 3 4 5 For U1 and CA only. Nutrition Adjustment Feed Enter value from range 0 to 255 8 Server IP Address Enter a value between 1 to 254 9 For U1 and CA only. For Client scale only. 12 Specification List SPEC NO. 195 196 197 198 199 200 201 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Weight Print for Non-weigh Item 0 No 1 Yes Scale File 0 Disable 1 Enable 2 3 Alphabetic 1 Cent Off 2 32 sec PLU Call Up Range 0 Disable 1 Enable Sell by Date for Manual Mode 0 Programmed Sell by Date 1 Zero Sell by Date Print Format of Month 0 Number 1 2 Alphabetic FSD Saving Calculation 0 Net Value FIS3000 Time Out 0 2 sec 1 8 sec SM-100 9 8 For U1 only. 8 202 Printing of Item Label when Barcode Data Overflow 0 Print 1 No Print 9 203 Preset Keys Pages 0 1 Page 1 3 Pages by Toggle 9 204 205 2 3 Pages by Shift Key Reference PLU Function Key Enable 0 Inhibit 1 Allow Print Function Key Enable 0 Inhibit 1 Allow 8 206 Print Barcode when Right Side Data Overflow 0 No print 1 Print Barcode Digits 207 Weight Decimal Point Position for Barcode and Label Printing 0 Same as SPEC607 1 0.000 208 209 210 211 212 213 214 Network Time Out 0 3 sec 1 x2 2 3 x4 x10 FSD Calculation 0 Unit Price 1 Price Percentage Off PLU Repeat Function Key Enable 0 Inhibit 1 Allow Pick ‘N’ Pay Protocol 0 Old 1 New 8 Effective when SPEC607 = 2. 8 For U1 only. 8 For SF only. 8 Department Number for Pick ‘N’ Pay Enter a value between 1 to 99 For SF only. Flag Code Function Key Enable 0 Inhibit 1 Allow DHCP Function 0 Disable 1 Enable 13 Specification List SPEC NO. 215 216 217 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION 9 Centering of Special Message 0 Yes 1 No JIS Code Table 0 New 1 Old 5 6 7 8 F5 F6 F7 F8 Default Label Format 2 for Item Printing 0 Not Used 1 F1 2 F2 3 F3 4 F4 SM-100 8 218 Zero Unit Price for Unit Price Change Function Key 0 Inhibit 1 Allow 219 Numeric Key Entry Reset 0 3 sec 1 5 sec For AA only. 9 2 Disable For AA only. Item Barcode Right Side Data Dependent on Unit 0 Disable 1 Enable 8 221 Receipt with Tax Information Function Key Enable 0 Inhibit 1 Allow 8 222 Open Cash Drawer without Sales Function Key Enable 0 Inhibit 1 Allow 9 223 Negative Unit Price Function 0 Disable 8 1 Enable FIS3000 Wire Type 0 4 wires 1 2 wires Prepack Grand Total for Individual PLU 0 Yes 1 No Reverse Calculation of ITF Check Digit 0 No 1 Yes Unit Price Override Password Function 0 Inhibit 1 Allow Individual PLU Total Transaction 0 No 1 Yes Preset Key Group 0 Disable 1 Enable Auto Print after PLU Call 0 No 1 Yes 220 224 225 226 227 228 229 230 Effective when SPEC1 = 0 or 2. 8 Effective when SPEC178 = 1. 9 Effective when SPEC150 = 1. 9 231 Zero Unit Price for PLU and Unit Price Override 0 Inhibit 1 Allow 9 232 Feed for Continuous Label 0 No 9 1 Yes Time Format 0 24 Hours 1 12 Hours (AM/PM) 233 9 14 Specification List SPEC NO. 234 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Sub-total and Grand Total Barcode 0 Based on Item Barcode SM-100 9 1 Based on Total Barcode 235 Mask Barcode Last Human Readable Check Digit 0 No 1 Yes 9 236 Character Generator for Korea 0 Old 8 1 New Half-key Function 0 Inhibit 1 Allow 2 SM-25 Dots 237 238 239 240 241 242 243 244 FIS3000 Free Format Unit 0 mm 1 Dots 9 9 Cheque and Credit Payment Function Key 0 Inhibit 1 Allow Voucher Payment Function Key 0 Inhibit 1 Allow PLU Code for IR POS and TMR 0 6 Digits 1 7 Digits Discount without Limit Function Key 0 Inhibit 1 Allow Concatenate Commodity Name Display 0 No 1 Yes Enable PLU Price Change Flag 0 No 1 Yes 8 245 Print Sell by Date or Used by Date when Date Equals Packed Date 0 Yes 1 No 246 Print First and Check Digits Outside Barcode 0 No 1 Yes Print Packed date 0 Manual and Prepack Mode 1 Manual 2 3 Prepack Mode No Print Print Sell by Date 0 Manual and Prepack Mode 1 Manual Mode 2 3 Prepack Mode No Print Print Used by Date 0 Manual and Prepack Mode 1 Manual Mode 2 3 Prepack Mode No Print Centering Shop Name on Label 0 No 1 Yes Shop Name on Receipt 0 Top 1 Bottom Auto Reconnect when Server Down 0 Disable 1 Every 2 min 2 3 Every 3 min Every 15 min 247 248 249 250 251 252 For KE only. 9 9 9 9 9 15 Specification List SPEC NO. 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Client Auto PLU Update 0 Update / Delete Existing PLU 1 Update / Delete All Sever PLU 2 Update Existing PLU 3 4 Update All Server PLU Disable Auto Update of Client Off-line Report 0 Disable 1 Enable Retry Ethernet Communication 0 2 times 1 5 times SM-100 8 Display Price with Tax after Clerk Key Press 0 Yes 1 No For AA only. Change Place Name to PLU via Function Key 0 No 1 Yes For AA only. Beef Labeling 0 No 1 Yes Auto Print Sub-total Label in Prepack 0 No 1 Yes Beef Labeling : Print Country 0 Code 1 Name External Rewinder 0 Disable 1 Enable Selection of Receipt / Label 0 Label 1 Receipt FSD Net Value Minimum 0 Off 1 On Print Ingredient Data on Next Label 0 Disable 1 Enable Client Using Local Free Format Label 0 No 1 Yes 2 Exact Weight 1 Second Language FSD Weight 0 Back Computed (Single Range) 1 Back Computed (Dual Range) CPDL Language Selection 0 First Language 9 9 8 8 For U1 only. 8 Exclude AA, HK, CN, TW and KE. 9 4 5 6 7 Individual Report Print and Clear in Z Mode 0 Disable 2 1 Manual Clear Store Total Report Clear 0 Store Total Report Only For U1 only. 8 Display Special Scale Message for Discounted Item 0 No 1 Yes Auto Clerk Accumulation (for scanner) 0 No 1 V1 2 V2 3 V3 Always set to 1 for SM200. 1 V4 V5 V6 V7 For IR only. Auto Clear All Report 16 Effective when SPEC270 = 1 or 2. Specification List SPEC NO. 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION 9 Beef Reference Number 0 Code 1 Date Item Code Follow PLU Number 0 Yes 1 No Bench Key Pad 0 New 1 Old Taiwan Receipt Printer 0 Disable 1 Enable Floating Server 0 Disable 1 Enable Real Time Buffer 0 No 1 2 Days 2 3 Days 3 4 Days 4 5 6 7 5 Days 6 Days 7 Days Unlimited 3 4 By Date and Reference No. By Date and PLU No. U1 Self-service 0 Disable 1 Enable Real Time Customer Number 0 No 1 Yes Real Time Buffer Receipt 0 Detail 1 Total Only Barcode Function 0 Without CR 1 With CR Barcode Look-up-table (LUT) Contents 0 Non-weigh Item Only 1 All Items Open Cash Drawer on Credit Payment 0 Allow 1 Inhibit Australia ECR Function 0 No 1 Yes Enforce Amount Tendered 0 No 1 Yes Enforce Change Key 0 No 1 Yes Planned Price Printed in Report 0 Enable 1 Disable Repeat PLU Call 0 No 1 Yes Payment Key 0 Disable 1 Enable Traceability Report 0 Disable 1 By Reference No. 2 By PLU No. SM-100 For IR only. 8 8 For TW only. Apply for POS1 FLEX PP2000 srs. 2 only. 9 9 8 For U1 only. 8 8 8 9 8 For AR only. 9 9 8 17 For DEC countries only. Specification List SPEC NO. 291 292 293 294 295 296 297 298 299 300 301 SM-110 V1.20 SPECIFICATION DESCRIPTION 1 No Change SM-200 Power Save 0 Back Light Off 1 Power Off 2 3 10 Min 2 Min 4 5 6 1 Min 2 Min 5 Min SM-200 Battery Option 0 Yes 1 No SM-300 Scrolling Message Update Rate 0 6 Lines 1 12 Lines Ingredient File-Size Expansion 0 Maximum 99 records 1 Maximum 255 records Print PLU Ingredient in Receipt 0 No 1 Yes Traceability Update Function 0 No 1 Yes 2 80 Preset Keys SM-500 Self-Service 0 No 1 Yes Print Receipt after Accumulation 0 Yes 1 No 1 Enable SM-200 Power Save Timeout 0 3 Min 1 5 Min PLU Scrolling Message Display Interval 0 Disable 1 3S 2 10S 3 30S Keyboard Selection 0 Normal Keyboard # 1 100 Preset Keys Fixed Port Number for Ethernet Enter value from 1 to 254 303 DHCP IP Address Lease Time 0 Disable 8 8 9 8 8 8 # 32/56 Preset Keys. Identical to SPEC672. 8 96 Preset Keyboard. Identical to SPEC688. 9 305 Character Spreading Speed Up 0 Disable 1 Enable Unit Print on Receipt 0 Pcs 1 Items Code Page 0 DOS 1 ANSI SM-500 2nd Receipt Printer 0 Disable 1 Enable Praxis Function 0 Disable 1 Enable 309 For SF only. 8 Server Port Number Enter value from 1 to 254 308 For U1 only. 8 304 307 SM-100 9 Gap Value In-feed Operation 0 Re-adjustable 302 306 20 December, 2005 8 (S3, S4, M3 & M4) For U1 only. 8 For IR only. 8 8 18 For DEC countries only. Specification List SPEC NO. 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION Multi Barcode Type 0 EAN128 1 RSS 9 2 CODE128 Operator Logging Function 0 Disable 1 Enable Price Change Password 0 Disable 1 Enable Price Change Log File 0 Disable 1 Enable 2 Enable (Clerk Report) 1 No Training Mode 0 Disable 1 Enable Print PLU Traceability in Receipt 0 Yes SM-100 For AI 01 only. 9 For CA only. 9 For CA only. 8 For DEC only. 8 9 Include Prepack Total in Manual Total Report 0 Yes 1 No Wireless Communication 0 No Yes 9 1 Wireless FTP Port Number Enter value range from 1 to 9999 Not in used. 9 Delete Traceability Record 0 Yes 1 No PLU Link to Text Field 0 Disable 1 Enable Julian Date for Packed and Sell Date 0 No 1 Yes Price Printing Size (Large Font) 0 No 1 Yes Auto PLU Broadcasting 0 Disable 1 Enable 8 For U1 only. 8 Decimal Point For Unit Price And Total Price 0 Disable 1 Enable Peel Sensor Value 0 Re-adjust 1 No Change ON/Off Key 0 Disable 1 Enable SM300 Print Control 0 Disable 1 Enable TU 9 Digit Total Price 0 Disable 1 Enable PLU Tare Call up 0 Allow 1 Inhibit Individual Scale Store Total Report 0 No 1 Yes 8 8 8 For Tu only. 8 8 19 Specification List SPEC NO. 331 332 SM-110 V1.20 SPECIFICATION DESCRIPTION 1 Enable ITEM Text (5-16) Print on Total Label 0 Disable 1 Enable 9 Image at Top Receipt Enter range from 0 to 99 334 Image at Bottom Receipt Enter range from 0 to 99 335 Traceability Eat By Date 0 Disable 1 Enable Traceability Max Weight 0 Disable 1 Enable 5 6 7 8 F5 F6 F7 F8 1 EAN128 337 338 Traceability Default Label Format 0 Not Used 1 F1 2 F2 3 F3 4 F4 Traceability Barcode 0 EAN13 339 Flag Data (EAN13) Enter range from 0 to 99 340 Enforce Scan 0 No 1 Yes TVP2000 (SM300) 0 Not Send T10 1 Send T10 Label Format LCD 1 Line Scroll 0 Disable 1 Enable Clear Key in Prepack 0 Enable 1 Disable Print Pack Date 0 Yes 1 No Update Spec For Server/Client System 0 Enable 1 Disable 341 342 343 344 345 346 347 348 349 SM-100 9 Default ITF for Barcode 0 Disable 333 336 20 December, 2005 Update Label Turn-over In Receipt Buffer 0 No 2 1 Only In Registration Mode 3 Only In Prepack Mode Both Internet Broadcast 0 No 1 Yes Taiwan POP Label 0 Disable 1 Enable Direct Access To Clerk Mode 0 Disable 1 Enable 20 For TW only Specification List SPEC NO. 350 351 SM-110 V1.20 SPECIFICATION DESCRIPTION Additional Rounding In Receipt 0 Print 1 No Print Gratuitous ARP 0 Disable 1 Enable 21 20 December, 2005 SM-100 Specification List SPEC NO. 400 401 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION SM-100 9 Auto Power-Off Function 0 Inhibit 1 3 Minutes 2 10 Minutes 3 4 5 30 Minutes 1 Hour 3 Hours RTS/CTS Handshaking of RS-232C 0 On 1 Off 9 402 Reset Receipt consecutive Number after Reset Report 0 No 1 Yes 9 403 Vender Number Display in Registration Mode 0 Allow 1 9 Inhibit Number of Vender Keys 0 4 Vender Keys 1 5 Vender Keys 6 Vender Keys 7 Vender Keys 404 9 2 3 405 Priority of Shop Name and Special Message on Receipt 0 Shop Name Priority 1 Special Message Priority 9 406 Centering of shop name on Receipt 0 Allow 9 407 1 Inhibit Centering of special Message on Receipt 0 Allow 1 Inhibit 9 408 One or Two Touch for Receipt Printing in AMT/TEND 0 One Touch 1 Two Touch 9 409 PLU Number Printing on Receipt 0 Inhibit 9 1 Allow Sale Item Entry Method 0 Total 1 Item 410 411 412 413 414 415 416 417 9 9 Default Vender Transaction by Print Key 0 Allow 1 Inhibit Print Checking Line 0 Print 1 No Print Source of Used by Date 0 Current Date 1 Packed Date 9 9 In-Store Barcode for Barcode Scanner Enter 0 F1F2 CCCCCC TTTT CD 5 1 F1F2 CCCCC TTTTT CD 6 2 F1F2 CCCC TTTTTT CD 7 3 F1F2 CCC TTTTTTT CD 8 4 F1F2 CC TTTTTTTT CD 9 F1F2 CCCCC XCD TTTT CD F1F2 CCCC XCD TTTTT CD F1F2 CCCCC PCD TTTT CD F1F2 CCCCC 0 TTTT CD #1: F1F2 - 20~29 #2: CC ~ CCCCCC Item code. #3: TTTT ~ TTTTTTTT Total Price 9 Non-PLU Item Enter by Barcode Scanner 0 Allow 1 Inhibit Barcode Scanner 0 Allow 1 Inhibit Centering of Commodity Name on Label 0 Allow 1 Inhibit 9 9 22 Specification List SPEC NO. 418 419 420 421 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION 9 Weight Data Synchronization Function 0 Allow 1 Inhibit Open Cash Drawer when Issue Label 0 Allow 1 Inhibit Print Grand Total on Sales Report 0 Allow 1 Inhibit 2 Receipt Data & Label Data Constitution of Report 0 Receipt Data 1 Label Data SM-100 9 9 9 422 Currency Symbol for Total Amount on Receipt 0 No Print 2 Suffixation 1 Prefixion 9 423 Print Total Number of Pieces on Receipt 0 Allow 1 9 424 425 426 Inhibit Total Barcode on Receipt for Total Price in 2nd Currency 0 Allow 1 Inhibit 9 Second Currency as Reference Price 0 No 1 For Receipt 9 2 3 For Label For Receipt and Label Print Tare Weight when Unit Price is 0 0 Allow 1 Inhibit For FR only. 9 427 Eliminate Cash Line on Receipt when No change Operation 0 Allow 1 Inhibit 9 428 PRINT Tax List on Receipt 0 Allow 9 1 Inhibit Non-Weigh PLU Unit Price Display 0 Total Price Column 1 Unit Price Column 429 Effective when SPEC603 =1 9 430 Items on PLU / Main Group / Dept / Tax Report 0 Registered Items 1 All Items 9 431 Eliminate Vender Data on Sales Report 0 Allow 9 432 1 Font Size for Commodity Name on Receipt 0 Standard Font Size 2 1 Larger Font Size Inhibit 9 Largest Font Size 433 Condition of Additional Price Rounding for Total Price 0 Cash Payment Only 1 Always 9 434 Item Barcode Type 0 EAN Type 1 ITF Type 9 435 Total Barcode Type 0 EAN Type 2 User Programmable 1 ITF Type 9 436 In-Store Barcode Type for Barcode Scanner Enter 0 EAN Type 1 ITF Type 9 437 Print Rounding on Receipt 0 Allow 9 1 Inhibit 23 Specification List SPEC NO. 438 439 440 SM-110 V1.20 20 December, 2005 SPECIFICATION DESCRIPTION 9 Print Sub-Total on Receipt 0 Allow 1 Inhibit Pulse width for Opening Cash Drawer 0 20ms (Default Value) 1 50ms 2 100ms 3 4 5 200ms 300ms 400ms 2 Power On & Password R Key R Mode Password Function 0 Inhibit 1 Password R Key SM-100 9 9 441 Set / Reset Auto PLU Call Function Key Enable 0 Allow 1 Inhibit 9 442 Change Main Group Code for Auto Plu Call Function Key Enable 0 Allow 1 Inhibit 9 443 Prefix Fixed Code to PLU Code for Auto PLU Calling 0 No 2 2 Digits 1 1 Digit 3 3 Digits 9 Decimal Point Position for Second Currency 0 None 2 1 0.0 3 9 444 0.00 0.000 445 Unit Price Change for PLU after Label Printing 0 Inhibit 1 Allow 446 Print Tare Weight on Receipt 0 Allow 447 448 449 450 451 452 453 454 455 Effective when Spec39 = 1, Spec40 = 0 9 1 Inhibit Place Change for PLU after Label Printing 0 Inhibit 1 Allow Sell Date Change for PLU after Label Printing 0 Inhibit 1 Allow For KE only. Trace Auto Clear 0 Inhibit 1 Allow For KE only. Trace per PLU 0 Inhibit 1 Allow For KE only. Trace Auto Update 0 Inhibit 1 Allow For KE only. Effective when Spec450 = 1. Trace Confirm 0 Inhibit 1 Allow For KE only. Trace C/D Check 0 Inhibit 1 Allow For KE only. 9 For KE only. 9 9 Forced Tare when Tare Value in PLU is 9999 0 Inhibit 1 Allow Printing of Servings Fact 0 SS Top & SC Bottom 1 SS Bottom & SC Top SS Print Only SC Print only For CA only. 9 2 3 24 For CA only. SM-110 Flexible Barcode Setting Guide Operation Display tare weight S1 -- --> S46 -- --> Unit price/kg Remark price Press [mode] third PLU FILE Enter programmer. times Enter Press numeric 4 and 6 Flexible Barcode FLEXI BARCODE programme. Press [*] S46.0 F BAR 0 NO SET Program Flexible Barcode. Enter numeric 1 S46.0 F BAR 1 NO SET Program Flexible Barcode 1. Press [*] S46.1 F BAR 0 FLAG Program Flag Code.(0 for F2,1 for F1F2,2 for non.) Press [*] S46.2 F BAR 0 ITEM CODE Enter item code length. Enter data format for DATA1.( 0 for weight,1 for quantity,2 for unit Press [*] S46.3 F BAR 0 DATA1 price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.) Press [*] S46.4 F BAR 0 DIGIT Enter DATA1 length. Shift for DATA1.( 0 for no right shift,1 for right shift, 2 for right Press [*] S46.5 F BAR 0 SHIFT shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3.) Enter data format for DATA2.( 0 for weight,1 for quantity,2 for unit Press [*] S46.6 F BAR 0 DATA2 price.3 for weight/quantity,4 for total price,5 for original price,6 for user programmable.) Operation Press [*] Display tare weight Unit price/kg price S46.7 F BAR 0 DIGIT Remark Enter DATA2 length. Shift for DATA2.( 0 for no right shift,1 for right shift, 2 for right Press [*] S46.8 F BAR 0 SHIFT shift x2, 3 for left shift, 4 for left shift x2, 5 for left shift x3.) Press [ⅹ] to select the middle Press [*] S46.9 F BAR NO MIDDLE CD check digit. Press [ⅹ] to select the last check Press [*] S46.1 F BAR NO LAST CD digit. Press [ⅹ] to swith ITF and EAN Press [*] S46.1 F BAR ITF BARCODE barcode. Press [#] S46 -- --> FLEXI BARCODE Save the flexible barcode 1. Note: See the Flexible Barcode Usage Note at 《3.6.1 PLU programming》 in SM-110 Operation manual. SM-110 Traceability Setting Guide Prepare ¾ Set SPEC258 to “1” Traceability Programming Operation Display Unit price/kg price Remark tare weight [Mode] [Mode] [Mode] S1 Æ PLU FILE [3] [4] S34 Æ COUNTRY FILE [*] [1] S34.0 [*][C][H][I][N][A] S34.1 COUN [#] S34 Æ COUNTRY FILE Save Country No. 1 [3] [5] S35 Æ CUTTING HALL Enter cutting hall programming [*] [1] S35.0 HALL 1 NO SET [*][1] S35.1 HALL 1 COUNTRY Program cutting hall country No. 1 [*][C][U][T] S35.2 HALL CUT Name 3 Program cutting hall name “CUT” [#] S35 Æ Enter S mode Enter country file programming 1 NO SET Program country No. 1 CHINA Name 5 Program country name “CHINA” CUTTING HALL Program cutting hall No. 1 Save cutting hall No. 1 Operation Display tare weight Unit price/kg price S36 Æ SLAUGHTER HOUSE Remark Enter [3][6] slaughter house programming [*][1] S36.0 HOUSE 1 NO SET [*][1] S36.1 HOUSE 1 COUNTRY Program slaughter house No. 1 Program slaughter house country No.1 Program slaughter house name [*][S][L][A][U][G] S36.2 HOUSE SLAUG NAME 5 “SLAUG” [#] S36 Æ [4][7] S47 Æ [*][1] S47.0 KIND 1 NO SET Program kind file No. 1 [*][M][E][A][T] S47.1 KIND MEAT NAME 4 Program kind name “MEAT” [#] S47 Æ KIND FILE [4][8] S48 Æ CATEGORY FILE [*][1] S48.0 CATEG 1 NO SET Program category No. 1 [*][B][E][E][F] S48.1 CATEG BEEF NAME 4 Program category name “BEEF” [#] S48 Æ SLAUGHTER HOUSE Save slaughter house No. 1 KIND FLIE Enter kind file programming CATEGORY FILE Save kind file No. 1 Enter category file programming Save category file No. 1 Operation Display Unit price/kg Remark tare weight price [4][9] S49 Æ [*][1] S49.0 BREED 1 NO SET Program breed file No. 1 [*][B][U][L][L] S49.1 BREED BULL NAME 4 Program breed name “BULL” [#] S49 Æ BREED FILE [3][7] S37 Æ TRACEABILITY [*][1] S37.0 TRACE 1 NO SET Program traceability No. 1 [*][1] S37.1 TRACE 1 BORN Choose born country No. 1 [*][1] S37.2 TRACE 1 FATTEN Choose fatten country No. 1 [*][1] S 37.3 TRACE 1 S HOUSE Choose slaughter house No. 1 [*][1] S37.4 S CNT 1 LNK 1 BREED FILE Enter breed file programming Save breed file No. 1 Enter traceability programming Choose link country No. 1 for slaughter house [*][1] S37.5 TRACE 1 C HALL [*][1] S37.6 C CNT 1 LNK 1 Choose cutting house No. 1 Choose link country No. 1 for cutting hall [*][1] S37.7 TRACE 1 ORIGIN Choose original country No. 1 Operation Display Remark tare weight Unit price/kg price [*][R][C][D] S37.8 R-CD RCD NAME 3 Program R-CD content “RCD” [*][G][T][I][N] S37.9 GTIN GTIN NAME 4 Program GTIN content “GTIN” [*][L][O][T] S37.10 LOT LOT NAME 3 Program LOT content “LOT” [*][1] S37.11 TRACE 1 KIND [*][1] S37.12 TRACE 1 CATEG Choose category No. 1 [*][1] S37.13 TRACE 1 BREED Choose breed No. 1 [*][C][O][N][T] S37.14 CONT CONT NAME 4 Program cont content “CONT” [*][0][6][0][3][1][0] S37.15 TRACE 060310 EAT D Program eat by date “06/03/10” [*][5][0][0][0] S37.16 TRACE 5.000 WEGHT Program maximum weight “5kg” [*][S][C][D] S37.17 S CD SCD NAME 3 Program S CD content “SCD” [*][S][N][M] S37.18 S NM SNM NAME 3 Program S NM content “SNM” [*][S][A][D][1] S37.19 S AD1 SAD1 NAME 4 Program S AD1 content “SAD1” [*][S][A][D][2] S37.20 S AD2 SAD2 NAME 4 Program S AD2 content “SAD2” [#] S37 Æ TRACEABILITY Choose kind No. 1 Save traceability No. 1 Free Format Programming ¾ ¾ Enter “S12 Æ FREE FORMAT”, press [*] Edit the correlative items for traceability in free format PLU ITEM Programming ¾ ¾ Enter “S19 Æ PLU ITEM”, press [*] Set “ Item TRACE” to “PROGRAM” and press [#] to save PLU Programming ¾ ¾ ¾ When you edit PLU, set “S1.64 PLU” to “TRACE ALLOW” and press [*] Input traceability number and press [#] to save In the end, when you call the PLU and print label, you’ll see the traceability information on the label SM-110 Nutrition Fact Setting Guide Concept Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81). Setting Method 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Enter S mode Enter “S19 --- PLU ITEM” and set “IMAGE” and “NUTRI” to “PROGRAM” Enter “S12 --- FREE FORMAT” Enter “S12.5 IMG 1 Å 47 F ITEM” to “S12.5 IMG 10 Å 56 F ITEM” to set the print area of Nutrition. (In each label format, totally you can print 10 images) Enter “S1 --- PLU FILE” to create PLU. Enter “S1.50 PLU 0 IMAGE 1” to choose the template number for IMAGE 1 (From No. 70~ No. 81). … Enter “S1.59 PLU 0 IMAGE 10” to choose the template number for IMAGE 10 (From No. 70~ NO. 81). Set “S1.81 PLU PRINT NUTRI” to set nutrition print status to “Print”. Enter from S1.82 to S1.10 to input nutrition contents. For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands. Enter “S12 --- FREE FORMAT” to set up the TXT position. Press [PLU] key to save. Operational Menu Tree Registration Mode ( R Mode ) Report Print Mode ( X Mode ) X1.1 X2.1 X3.1 X4.1 X5.1 X6.1 X7.1 X8.1 X3.2 X4.2 X5.2 X8.2 X1.4 X2.4 X3.4 X4.4 X5.4 X6.4 X9.4 X4.3 Programming Mode ( S Mode ) S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 S21 S22 Read Main Group Daily Read PLU Daily Read Department Daily Read Sales Daily Read 24 Hour Daily Read ABC Daily Read Clark Daily Read Pre-pack Department Daily Read Department Monthly Read Sales Monthly Read 24 Hour Monthly Read Pre-pack Main Group Daily Read Main Group Term Read PLU Term Read Department Term Read Sales Term Read 24 Hour Term Read ABC Term Read Tax Read Store Summary PLU File…… Department File Main Group File Key Assignment Shop Name File Advertisement Message Vender File Date and Time Special Message Ingredient File Text File Free Format…… Scroll Message Scroll Sequence Place File Machine Setting Logo File Tax File PLU Item…… Memory Status I/F Test File Load 1 ¾ S1 PLU File S1.0 S1.1 S1.2 S1.3 S1.4 S1.5 S1.6 S1.7 S1.8 S1.9 S1.10 S1.11 S1.12 S1.13 S1.14 S1.15 S1.16 S1.17 S1.18 S1.19 S1.20 S1.21 S1.22 S1.23 S1.24 S1.25 S1.26 S1.27 S1.28 S1.29 S1.30 S1.31 S1.32 S1.33 S1.34 S1.35 S1.36 S1.37 S1.38 S1.39 S1.40 S1.41 S1.42 S1.43 S1.44 S1.45 S1.46 S1.47 S1.48 Enter PLU No. Unit Price (PR-KG or PR-PCS) Label Format 1 (Default, T1-T12, S, A-C, F1-F99) Label Format 2 (No, F1-F99) Commodity Name and its Font Size EAN Barcode or ITF Barcode Barcode Type Flag Code Item Code Item Code (Lower 4 Digits) Right Side Data of Item Barcode Selection of EAN Add-on Main Group Number Print Sell by Date or Not Sell by Date [Enabled when S1.13 is set to print] Print Sell by Time or Not Present or Key-in [Enabled when S1.15 is set to print] Sell by Time [Enabled when S1.16 is set to Key-in] Print Used by Date or Not Used by Date [Enabled when S1.18 is set to print] Print Packed Date or Not Packed Date [Enabled when S1.20 is set to print] Print Packed Time or Not Present or Key-in [Enabled when S1.22 is set to print] Packed Time [Enabled when S1.23 is set to Key-in] Cost Price PLU Tare Unit Symbol Quantity Type of Volume Discount The 1st Target of Volume Discount The Discount Value for the 1st Target The 2nd Target of Volume Discount The Discount Value for the 2nd Target Print Type of Discount Price (Mark Down) Schedule of Volume Discount (The Start Date) Schedule of Volume Discount (The Start Time) Schedule of Volume Discount (The End Date) Schedule of Volume Discount (The End Time) Selection of Discount Day of the Week Special Message Number Ingredient Number Special Message (Program Original Special Message) Ingredient (Program Original Ingredient) Place of Production Coupled PLU Number Tax Number Reference PLU Number Proportional Tare 2 ¾ S12 Free Format S12.5 Free Format Item S12.0 S12.1 S12.2 S12.3 S12.4 S12.5 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. Free Format Number Label Width Label Height Label Angle Label Type (Item Label or Total Label) Free Format Item…… PLU Number Price Unit Price Weight Quantity Packed Date Packed Time Commodity Quantity Unit Sell by Date Sell by Time Barcode Shop Name Discount Used by Date Logo Main Group Code Department Scale Number Ingredient Special Message Frame 1 Frame 2 Tare Clerk Text 1 Text 2 Text 3 Text 4 Text 5 Text 6 Text 7 Text 8 Text 9 Text 10 Text 11 Text 12 Text 13 Text 14 Text 15 Text 16 3 ¾ S19 PLU Item Label Format 1 [LABFR1] Label Format 2 [LABFR2] Barcode Selection [BACODE] Barcode Flag Data [FLAG] Barcode Item Code [ITCODE] Main Group Code [MGCODE] Sell by Date [SELLDT] Sell by Time [SELLTM] Used by Date [USEDDT] Packed Date [PACKDT] Packed Time [PACKTM] Cost [COST] Tare [TARE] Quantity [QTY] Quantity Unit [Q .UNIT] Discount Status [DISCNT] Discount Schedule Date [SCH DT] Discount Schedule Time [SCH TM] Mark Down Status [MARKDN] 1st Target for Discount 1 [1STLMT] 2nd Target for Discount 2 [2NDLMT] Special Message Number [SMGNUM] Ingredient Number [INGNUM] Commodity Name [COMNAM] Special Message [SP MG] Ingredient [INGR] Place of Production [PLCNUM] Image [IMAGE] Bonus [BONUS] Nutrition [NUTRI] ITF Selection [ITFSEL] Reference PLU [REFPLU] Security PLU [SECPLU] Coupled PLU [COUPLU] Discount Day of the Week [DAY WK] EAN 5 Digit Add-on [ADD-ON] Tax Number [TAX] 2nd Price [PRICE2] Proportional Tare [% TARE] Customer Discount [CUSDIS] Restaurant Discount [RESDIS] Staff Discount [STADIS] Traceability Discount [TRACE] Storage Temperature [TEMP] Pack. Indicator [PACK.I] Multi Barcode 1 [M1BARC] Multi Barcode 2 [M2BARC] Total Multi Barcode 1 [TM1BAR] Total Multi Barcode 2 [TM2BAR] Unit Price Selection [U.PRIC] PLU Scroll (U1 only) [PLUSCR] PLU Linked Text Field [PLUTEX] 4 Reset Report Mode ( Z Mode ) Z1.0 Reset Sales Daily Z2.0 Reset Sales Monthly Z3.0 Reset Sales Term 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 147 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:4e48beeb-8f19-469b-bdb1-5a076a4ae80f Producer : Acrobat Distiller 6.0 (Windows) Modify Date : 2012:08:24 13:42:11+08:00 Create Date : 2012:08:24 13:38:40+08:00 Metadata Date : 2012:08:24 13:42:11+08:00 Document ID : uuid:2fb77c24-6c44-4dde-8823-2217faa5e9c0 Format : application/pdf Title : untitledEXIF Metadata provided by EXIF.tools