OPERATION MANUAL

MODEL :

SM-110
‹ EDITION
st

1
2nd
3rd
4th

Month
Year
January
2008__
___________
___________
_____

SHANGHAI TERAOKA ELECTRONIC CO., LTD
TECHNICAL SUPPORT DEPARTMENT
3rd Floor of 2nd Building, Jia Yuan Business Center,
51# Long Wu Road, Shanghai China 200232.
TEL : +86-21-6408-5151
FAX : +86-21-6408-3468
EMAIL ADDRESS :steservice@digi-scale.com

Notice
Welcome to use DIGI’s product. Please see the operation manual and learn how
to use our products. Thank you!

Table of Content
1. GENERAL ......................................................................................................................1
1.1 Overall View ......................................................................................................1
1.2 Display Panel .....................................................................................................3
1.3 Key Panel ...........................................................................................................3
1.4 Thermal Printer Head ......................................................................................8
1.5 Features ..............................................................................................................9
1.6 Specifications .................................................................................................. 10
1.6.1 Display ........................................................................................................................................................10
1.6.2 Operating Conditions .....................................................................................................................10
1.6.3 Dimensions .............................................................................................................................................10

1.7 Label Type....................................................................................................... 11

2. INITIAL SETUP.....................................................................................................12
2.1 Setup ................................................................................................................ 12
2.2 Location of Switches and Connectors........................................................ 14
2.3 Mode Change.................................................................................................. 14
2.4 Memory Initialization .................................................................................... 15
2.5 Specification Setting ...................................................................................... 15
2.6 Password Setting........................................................................................... 16
2.6.1 Procedures of Password Setting .............................................................................................16
2.6.2 Password Using ....................................................................................................................................16

2.7 Clear Files........................................................................................................ 17

3. PROGRAM MODE ...............................................................................................18
3.1 Programmable Files....................................................................................... 18
3.2 General Explanation...................................................................................... 19
3.3 Department Files ........................................................................................... 20
3.3.1 Program Department File ...........................................................................................................20
3.3.2 Delete Department File.................................................................................................................21

3.4 Main Group Files........................................................................................... 22
3.4.1 Program Main Group File...........................................................................................................22
3.4.2 Delete Main Group File ................................................................................................................23

3.5 Program / Skip Item Data ........................................................................... 24
3.6 PLU Programming ........................................................................................ 26
3.6.1 Program PLU File(weighing item) ........................................................................................30
3.6.2 Program PLU File(non-weighing item).............................................................................33
3.6.3 PLU [COPY] Function ..................................................................................................................37
3.6.4 Delete PLU File ...................................................................................................................................38
3.6.5 Volume Discount & Mark Down print function.......................................................39

3.7 Memory Status................................................................................................ 41
3.8 Key Assignment ............................................................................................. 42
3.8.1 PLU Assignment.................................................................................................................................42
3.8.2 Function Key Assignment ...........................................................................................................42
3.8.3 Delete Preset Key Assignment ................................................................................................43

3.9 Shop Name File.............................................................................................. 44
3.9.1 Program Shop Name File ............................................................................................................44
3.9.2 Delete Shop Name File .................................................................................................................45

3.10 Advertisement File ...................................................................................... 46
3.10.1 Program Advertisement File...................................................................................................46
3.10.2 Delete Advertisement File ........................................................................................................47

3.11 Vender File.................................................................................................... 48
3.12 Program Date And Time............................................................................ 49
3.13 Special Message File .................................................................................... 50
3.13.1 Program Special Message File ...............................................................................................50
3.13.2 Delete Special Message File.....................................................................................................51

3.14 Ingredient File .............................................................................................. 52
3.14.1 Program Ingredient File .............................................................................................................52
3.14.2 Delete Ingredient File ..................................................................................................................53

3.15 Text File ........................................................................................................ 54
3.15.1 Program Text File ...........................................................................................................................54

3.15.2 Delete Text File.................................................................................................................................55

3.16 Free Format File .......................................................................................... 56
3.16.1 General Information.....................................................................................................................56
3.16.2 Print Area, Print Position and Print Angles ................................................................57
3.16.3 Programming Parameter Of Print Items......................................................................59
3.16.4 Free Format Entry..........................................................................................................................61
3.16.5 Free Format Copy Function ...................................................................................................66
3.16.6 Free Format Delete Function ................................................................................................66
3.16.7 Sample of program a format by modifying the existing format ................67

3.17 Place File ....................................................................................................... 70
3.17.1 Program Place File .........................................................................................................................70
3.17.2 Delete Place File...............................................................................................................................70

3.18 Machine Setting............................................................................................ 71
3.19 Logo File ....................................................................................................... 72
3.19.1 Pre-programming Logo Data ................................................................................................72
3.19.2 Program Display & Keys Function ...................................................................................73
3.19.3 Programming Order......................................................................................................................74
3.19.4 Program Logo File .........................................................................................................................74
3.19.5 Delete Logo File ..............................................................................................................................75

3.20 Tax File.......................................................................................................... 76
3.20.1 Program Tax File .............................................................................................................................76
3.20.2 Delete Tax File ..................................................................................................................................77

3.21 Scroll Message File ...................................................................................... 78
3.21.1 Program Scroll Message File ..................................................................................................78
3.21.2 Delete Scroll Message File........................................................................................................78

3.22 Scroll Sequence File..................................................................................... 79
3.22.1 Program Scroll Sequence File ................................................................................................79
3.22.2 Enable or Disable Scroll Sequence File .........................................................................80
3.22.3 Delete Scroll Sequence Number ..........................................................................................81

3.23 ASCII Character Input Method ................................................................ 82
3.24 ASCII Code Input Method........................................................................ 83

4. REGISTRATION MODE .............................................................................. 84
4.1 ON/OFF ........................................................................................................ 84
4.2 Reset and Weighing Check........................................................................... 84
4.3 Tare Subtraction............................................................................................. 85
4.3.1 One touch Tare Subtraction ......................................................................................................85
4.3.2 Digital tare Subtraction ..................................................................................................................85

4.4 PLU Call Up ................................................................................................... 86
4.4.1 Manual PLU Call Up .......................................................................................................................86
4.4.2 PLU Call Up by Preset Key........................................................................................................86
4.4.3 PLU Call by Numeric Key (Auto PLU Call) .................................................................86

4.5 Fix Operation ................................................................................................. 87
4.5.1 Fix Tare by FIX Key ........................................................................................................................87
4.5.2 Fix PLU by FIX Key .......................................................................................................................87
4.5.3 Fix Unit Price by FIX Key ..........................................................................................................87

4.6 Operation Mode Change .............................................................................. 88
4.7 Item Label Printing in Manual Mode ......................................................... 89
4.7.1 Label Printing for PLU Item .....................................................................................................89
4.7.2 Label Printing for NON-PLU Item.....................................................................................90

4.8 Total Label Printing in Manual Mode ........................................................ 91
4.8.1 Sales Transaction ................................................................................................................................91
4.8.2 [PRICE DISCOUNT] Function Key in Add Mode ...............................................92
4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode ........................................92

4.9 Data Correction.............................................................................................. 93
4.9.1 On The Spot Correction ..............................................................................................................93
4.9.2 Void by Item Correction...............................................................................................................94

4.10 Item Label Printing in Pre-pack Mode .................................................... 95
4.10.1 Item Label Issue for PLU Item ............................................................................................95
4.10.2 Item Label Issue for NON-PLU Item............................................................................96

5. READ REPORT MODE ................................................................................. 97
5.1 Report Factor Select...................................................................................... 97
5.2 Report Type Selection................................................................................... 97
5.2.1 Main Group Report..........................................................................................................................99
5.2.2 PLU Report ............................................................................................................................................99
5.2.3 Department Report ........................................................................................................................100
5.2.4 Sales Report ........................................................................................................................................101
5.2.5 24Hour Report ...................................................................................................................................101
5.2.6 ABC Report ..........................................................................................................................................101
5.2.7 Clerk Report .........................................................................................................................................102
5.2.8 Pre-pack Report.................................................................................................................................103
5.2.9 Tax Report .............................................................................................................................................104
5.2.10 Store Summarized Report.......................................................................................................104

6. RESET REPORT MODE ............................................................................. 105
7. Apendix ......................................................................................................................... 106
A. Specification List
B. Flexible Barcode Setting Guide
C. Traceability Setting Guide
D. Nutrition Setting Guide
E. Operational Menu Tree

SM 110

GENERAL

1. GENERAL
1.1 Overall View
z

Bench Type

z

Pole Type

1

SM 110

GENERAL

1.2 Display Panel
z

25 digits × 19 segments TN type LCD

z

32 × 202 full dot Martix Green LCD

1.3 Key Panel
z

32 Preset Keys Type

z

56 Preset Keys Type

2

SM 110

GENERAL

ON/OFF KEY

™ Turn display "ON" or "OFF".

PRESET KEY

P1 ~ P40 (B)
P1 ~ P74 (EV)

™ Set up or call either unit price and tare value.

NUMERIC KEYS

0~9

™ Enter numeric data.

TARE KEY
™ Set or Clear Tare value.
™ Select "NO" in S and Z Mode.
™ Item test print in S Mode.
CLEAR KEY

C

™ For Back space or Clear numeric value.
™ Select "YES" in S and Z Mode.

RE-ZERO KEY

™ Reset weight to ZERO.

PREPACK KEY

AUTO

™ Switch Manual mode and Pre-pack mode alternatively.
(The mode status will be indicated in the P and M indicator.)
▪P - PRE-PACK MODE
▪ M - MANUAL MODE

CHANGE KEY
™ Calculate the Changed Amount.
™ Escape the Programming screen without saving data in S Mode.

3

SM 110

GENERAL

MULTIPLLE KEY
™ Register the number of Non-Weight products.

X

™ Select programming item such as PLU data, Shop Name in S Mode.
™ Select Report Type in X Mode.
™ Select Data Transaction Type in Z Mode.

CLERK KEY

V1~V4

™ Accumulate the Total Price.

VOID KEY

−

™ Correct the sales data.

PLU KEY

PLU

™ Call up PLU data in R Mode.
™ Store the programmed data in S Mode.

FEED KEY

™ Feed Label or Receipt paper

PRINT KEY

™ Print out Label or Receipt.

6

SM 110

GENERAL

MODE SELECT KEY
™ Five Modes can be selected using this key.
•

Indicator R - REGISTRATION MODE (All the sales transactions are
performed.)

•

Indicator X - CHECK MODE (Printing out and sales report.)

•

Indicator S - PROGRAM MODE (Programming preset data, such as
products, data, shop name, etc.)

•

Indicator Z - TOTAL MODE (Clear sales data stored.)

•

Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X, S, Z
mode, set PASSWORD for PASSWORD MODE when all indicators(R, X, S,
Z) blink)

Decrease/Increase Specification Count key

《,》

™ Decrease/Increase Only used when Setting SPEC 141 & 142

<<,>>

™ Select parameter data such as SPEC data. Move cursor left or right.

7

SM 110

GENERAL

1.4 Thermal Printer Head
z
z

Thermal Head Model: TDK LHE4253SU
Max Printing With: 56mm

z

Compare of Two Thermal Head Types of SM Series Scales
SM-100, SM-80L, SM-300
Thermal Head Model
TDK LHE4253SU
Max Printing Width
56mm

Thermal Head Photo

8

SM-80, SM-500
TDK LH-3139K
60mm

SM 110

GENERAL

1.5 Features
y

Digital printing scale consists of electronic cash registers function and label printing function.

y

High-speed, high reliability thermal head printer.

y

Easy paper handing achieved special designed mechanism.

y

Built-in clock automatically updates data and time.

y

Quick response to weight changes.

y

Capacity

: 15lb and 30lb.

y

Resolution

: Display Resolution 1/3, 000
: Internal Resolution 1/90,000

y

Calibrating by software.

y
y

Customer and operator display (optional customer pole display).
25 digits x 19 segments TN type LCD with back-light for numeric digit and character display.
32 x 202 full dot Martix Green LCD display.

y

55/83 membrane keys
a.

ON/OFF key

b.

10 Numeric keys, to key in numeric data.

c.

32/56 Preset keys, to preset PLU or function into the key.

d.

23/27 Operational keys, to perform various functional operations.

y

18 data files for Department, Main Group, PLU, etc.

y

Various reports.

y

Ethernet function.

y

Optional wireless Ethernet card.

y

RS232C interface for data communicate and barcode scanner connection.

y

Optional cash drawer.

y

Compact housing.

9

SM 110

GENERAL

1.6 Specification
1.6.1 Display
25 digits × 19 segment TN type LCD with back-light for numeric digit and character display.
y Tare weight display : 4 digits.
y

Weight display

: 5 digits.

y

Unit price display

: 6 digits.

y

Total price display

: 7 digits.

32 x 202 full dot Martix Green LCD display.
y

Tare weight display

: 4 digits.

y

Weight display

: 5 digits.

y

Unit price display

: 6 digits.

y

Total price display

: 7 digits.

1.6.2 Operating Conditions
z Power Source

: AC 176V ~ 264V, 47~63Hz.

z Operating Temperature

: -10 °C ~ +40 °C.

z Operating Humidity

: 15% ~ 85% RH.

z Power Consumption

: 0.15A.

1.6.3 Dimensions
z

Platter size
359(W) x 277(D) mm.

z

Overall size

a)

Bench

: 383.4(W) x 389.3(D) x 162(H) mm.

b)

Pole

: 383.4(W) x 419.3(D) x 552.6(H) mm.

10

SM 110

GENERAL

1.7 Label Type

Note: Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the
core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the
use of varnish labels.

Label Type
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
S
A
B
C
F1 – F99

Dimension (mm)
28 X 56
31 X 56
34 X 56
40 X 56
43 X 56
46 X 56
49 X 56
55 X 56
37 X 56
40 X 56
43 X 56
49 X 56
28 X 37
46 X 37
46 X 37
62 X 37
Free Format

11

SM 110

INITIAL SETUP

2. INITIAL SETUP
2.1 Setup
¾ Indication of Assemble
(1) Use 4

screws to fix the Pole.

(1) Use 1 flat screws to fix the Pole.

12

SM 110

INITIAL SETUP

¾ Bubble Adjustment

Bubble

Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the
centre as shown above.

13

SM 110

INITIAL SETUP

2.2 Location of Switches and Connectors

Ethernet Port

RS232 Port
Cash Drawer Port

Fuse
Holder
Power
Switch

2.3 Mode Change
DISPLAY
OPERATION
PT

kg

$/kg

$

0.000

0.000

0.00

0.00

[MODE],[MODE]

REMARK
Weight mode.Lamp R turns on.

XMODE

(within 3 seconds)

Enter X mode.Lamp X turns on.

[MODE]

S1

→

PLU

FILE

Enter S mode.Lamp S turns on.

[MODE]

Z1.0

RESET

SALES

DAILY

Enter Z mode.Lamp Z turns on.

PWD X

0

SET

Enter Password Set mode.Lamp X flicker

0.000

0.00

0.00

Back to Weight mode.Lamp R turns on.

[MODE]
[MODE]

0.000

2.4 Memory Initialization
To clear all memory.
DISPLAY
OPERATION
PT

kg

$/kg

$

Z1.0

RESET

SALES

DAILY

REMARK
Z mode.
Lamp Z turns on.

DISPLAY
OPERATION
PT

kg

$/kg

$

14

REMARK

SM 110

INITIAL SETUP

[Rezero]+[2][3][0]

CLEAR

PLU

FILE

[》]

CLEAR

VENDER

DATA

Vender transaction data.

[》]

CLEAR

REPORT

FILES

Report files.

[》]

CLEAR

MEMORY

DATA

All files in memory.

[*]

CLEAR

MEMORY

Y-C N-T

[C] to clear file data,[T] to quit.

RESET

SALES

DAILY

Return to Z mode.

[C] or [T]

Z1.0

PLU file.

2.5 Specification Setting
Before setting 141, please enter Z mode.
DISPLAY
OPERATION
PT

kg

$/kg

$

Z1.0

RESET

SALES

DAILY

XXX

XXX

(setting)

(former)

[Rezero]+[1][4][1]

SPEC 000

REMARK
Z mode.
Lamp Z turns on.
Enter [1][4][1] while depressing
[Rezero].
XXX:SPEC data
[》]key only increase specification

[》]

SPEC 001

XXX

XXX

count, it does not update SPEC
data.
[《]key only decrease specification

[《]

SPEC 000

XXX

XXX

count, it does not update SPEC
data.

[1][7]

SPEC 000

017

XXX

[X]

SPEC 017

XXX

XXX

[>>]

SPEC 017

XXX

XXX

[<<]

SPEC 017

XXX

XXX

[1]

SPEC 017

001

XXX

[*]

SPEC 018

XXX

XXX

[C]

SPEC 018

000

XXX

RESET

SALES

DAILY

[PLU]
* Note 1

Z1.0

Note: Please see Appendix A for the detail specification list

15

It goes to a designed specification
count.
(000~441 is enabled)
[>>] key select SPEC data.
Move cursor right.
[<<] key select SPEC data.
Move cursor left.

Clear the enter data.
Store the updated specification and
escape to Z mode.

SM 110

INITIAL SETUP

2.6 Password Setting
2.6.1 Procedures of Password Setting
DISPLAY
OPERATION
PT

kg

$/kg

$

Z1.0

RESET

SALES

DAILY

REMARK
Z mode. Lamp Z turns on.
Display password for X mode .
XXXX: former password

[MODE]

PWD X

XXXX

SET

0: Not set
(1~4 bits are enable)Lamp X
flicker.
Set password for X mode as 1234.

[1][2][3][4]

PWD X

1234

SET

Press [*] to save password for X

[*]

PWD S

XXXX

SET

mode.
Lamp S flicker.

[*]

PWD Z

XXXX

SET

[3][3]

PWD Z

33

SET

[C]

PWD Z

0

SET

[*]

PWD P

XXXX

SET

Display password for Z mode.
Lamp Z flicker.
Clear the password for Z mode.

Display password for PWD mode.
Lamp R X S Z flicker.
Set password for PWD mode as

[1][1][1][1]

PWD P

1111

SET

1111.
Lamp R X S Z flicker.

[*]

0.000

0.000

0.00

0.00

Return R mode after password
setting.

2.6.2 Password Using
{Hypothesis: PWD X: 1111; PWD S: No Set; PWD P: 1234}
DISPLAY
OPERATION

[MODE],[MODE]
(within 3 seconds)
OPERATION

PT

kg

$/kg

$

0.000

0.000

0.00

0.00

ENTER

PWD X

DISPLAY

16

REMARK
Weight mode.
Lamp R turns on.
Need X mode password.
Lamp X turns on.
REMARK

SM 110

INITIAL SETUP
kg

$/kg

$

[1][2][3][4]

ENTER

PWD X

****

[*]

ENTER

PWD X

[1][1][1][1]

ENTER

PWD X

****

X1.0

READ

SALES

DAILY

S1

→

PLU

FILE

PT

[*]
[MODE]

Incorrect password.
Retry.
Correct password.
Enters X mode.
Enters S mode.
Lamp S turns on.
Need Z mode password.

[MODE]

ENTER

PWD Z

[3][3]

ENTER

PWD Z

**

RESET

SALES

DAILY

[MODE]

ENTER

PWD P

[1][2][3][4]

ENTER

PWD P

****

Correct password.

[*]

PWD X

1111

SET

Enters PWD mode.

0.000

0.00

0.00

[*]

Z1.0

[MODE]

0.000

Lamp Z turns on.
Correct password.
Enters Z mode.
Need PWD mode password.

Back to Weight mode.
Lamp R turns on.

2.7 Clear Files
This function is used to clear files in Memory.

DISPLAY
OPERATION

REMARK

PT

kg

$/kg

$

Z1.0

RESET

SALES

DAILY

[Rezero]+[2][3][0]

CLEAR

PLU

FILE

[》]

CLEAR

VENDER

DATA

Vender transaction data.

[》]

CLEAR

REPORT

FILES

Report files.

[》]

CLEAR

MEMORY

DATA

All files in memory.

[*]

CLEAR

MEMORY

Y-C N-T

[C] to clear file data,[T] to quit.

RESET

SALES

DAILY

Return to Z mode.

[C] or [T]

Z1.0

17

Z mode.
Lamp Z turns on.
PLU file.

SM 110

PROGRAM MODE

3. PROGRAM MODE
3.1 Programmable Files
In Programming Mode, there are two ways to select the Programming File by using different keys such as:
•

Enter the Number key.

•

Press [《] key or [》] key to select the Data File.

The files listed below can be programmed in PROGRAM Mode (S Mode).
Key To Press

Data files

Key To Press

Data files

[1]

PLU Programming

[1] [7]

Logo Programming

[2]

Department Programming

[1] [8]

Tax Programming

[3]

Main Group Programming

[1] [9]

Program or Skip Item Data

[4]

Key Assignment

[2] [0]

Memory Status

[5]

Shop Name Programming

[2] [1]

I/F Test

[6]

Advertisement Programming

[2] [2]

File Load

[7]

Vender Programming

[8]

Date and Time Programming

[9]

Special Message Programming

[1] [0]

Ingredients Programming

[1] [1]

Text Programming

[1] [2]

Free Format Programming

[1] [3]

Scrolling Message Programming

[1] [4]

Scroll Sequence Programming

[1] [5]

Place Programming

[1] [6]

Machine setting

18

SM 110

PROGRAM MODE

3.2 General Explanation
DEPARTMENT, MAIN GROUP and PLU files are connected as shown below. By the following
linking method, more detail and concrete information on sales transaction or pre-pack data can be got by
printing various reports.
Š DEPARTMENT FILE
DEPARTMENT file is the largest category whose items are like MEAT, FISH, VEGETABLE or
DELICATESSEN etc.
Š MAIN GROUP FILE
MAIN GROUP file is the middle category including items such as BEEF, PORK, CHICKEN, etc.
You can link a Main Group to a Department in the Main Group file. Tax Number can be assigned to
a Main Group. The assigned Tax Number will apply for all the PLU’s assigned to the Main Group.
Š PLU FILE
PLU File is the smallest category including items such as BEEF SLICE, BEEF SHOULDER and
BEEF SIRLOIN. You can link the PLU to a Main Group in the PLU programming file.
C onnection o f DEPA RT M E NT, M AIN G RO U P and P LU :

SHO P

D EPT.

M .G .

P LU

PLU

M .G.

PLU

Departm ent File

D EPT.

P LU

M .G.

PLU

PLU

19

M ain G roup File

M .G .

P LU

PLU

PLU File

SM 110

PROGRAM MODE

3.3 Department Files
Department file is used for categorizing Main Groups. Department Number between 1 ~ 99 are
available for programming. The Main Groups that are not linked to any Department will be assigned to
Department Number 97 automatically. Maximum 16 characters per file are available and each with 1
line.

3.3.1 Program Department File
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S2

→

DEPT

FILE

[*]

S2.0

DEPT

0

NO SET

[1]

S2.0

DEPT

1

NO SET

[*]

S2.1

DEPT

[MODE][MODE]
[MODE]
[2] or [X]、[》]

NAME 0

REMARK
Enter S mode.
Lamp S turns on.
Select Department Programming.
$ /kg window displays DEPT.
code.
Enter department No.(Ex. [1])
Enter department programming,
set the department name.
Enter

DEPT.

name(use

letter

keys)(Ex. “MEAT” for Dept. No
[M][E][A][T]

S2.1

DEPT

MEAT

NAME 4

1)
The methods of ASII letter input
refer to 3.23 ASSII Character Input
Method.

[PLU]

S2

→

DEPT

FILE

Store the department file, back to S
mode.

Note1: Number after "NAME" in Total display shows the position of the cursor.
Note2: The DEPT. No.1 to No.99 are available for programming.
(No.97 is default No. for PLU programming, and the PLUs which are not linked to any DEPT No. are assigned
to No.97)
(Non-PLU files (Weighing items) are assigned to DEPT code No.98)
(Non-PLU files (Non-weighing items) are assigned to DEPT code No.99)
Note3: The Department names programmed are not printed on the label/receipt but are for reporting.

20

SM 110

PROGRAM MODE

3.3.2 Delete Department File
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S2

→

DEPT

FILE

[*]

S2.0

DEPT

0

NO SET

[1]

S2.0

DEPT

1

NO SET

[-]

S2.0

DEPT

DEL ?

Y-C N-T

[C]

S2

→

DEPT

FILE

[MODE][MODE]
[MODE]
[2] or [》]

REMARK
Enter S mode.
Lamp S turns on.
Select Department Programming.
$ /kg window indicates DEPT.
code.
Enter department No.(Ex. [1])
Delete Dept. No.1 for “MEAT”.
[C] for Yes, [T] for No.
Delete the Dept. file 1,
back to S mode.

Note1: When the MAIN GROUP FILE exists under the Department File, the Department Number cannot be
deleted. In addition, the Department Number 97, 98 and 99 cannot be deleted.

21

SM 110

PROGRAM MODE

3.4 Main Group Files
Main Group is the middle category and can be assigned to a Department. The Main Group file is used
for categorizing the PLU's. Main Group Number of 1 ~ 999 are available for programming. PLU's that
are not linked to any Main Group Number will be assigned to the Main Group Number 997
automatically. TAX is assigned to every Main Group. The assigned TAX will apply for all the PLU's
assigned to the Main Group. Up to 250 data can be programmed in Main Group file. Maximum 16
characters per file are available and each with 1 line.

3.4.1 Program Main Group File
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S3

→

MGROUP

FILE

[*]

S3.0

MG

0

NO SET

[1][1][1]

S3.0

MG

111

NO SET

[*]

S3.1

MG

[1]

S3.1

MG

[*]

S3.2

MG

[B][E][E][F]

S3.2

MG

BEEF

NAME 4

[*]

S3.3

MG

0

TAX NO

[1]

S3.3

MG

1

TAX NO

[MODE][MODE]
[MODE]
[3] or [》]

97
(default)
1

DEPT NO
DEPT NO
NAME 0

REMARK
Enter S mode.
Lamp S turns on.
Select Main Group Programming.
$ /kg

window

indicates

Main

Group code.
Select Main Group No.
(Ex. [1][1][1])
Enter Main Group programming,
Set the Department number.
Link

Main

Group

111

to

Department 1.
Name of the Main Group 111 is
“BEEF’.
Set the Tax number.
Tax of Main Group 111 is tax
number 1.
Store the Main Group file, back to S

[PLU]

S3

→

MGROUP

FILE

mode. If you want to exit without
saving data, press [◇] key and then
follow by [C] key

Note1: For tax rate programming, refer to 3.20 Tax File in S Mode. if not necessary to link the Tax Number, press [*]
key to enter next selection. This procedure will skip if SPEC 603 is set to "NO TAX".
Note2: Number after "NAME" in Total display shows the position of the cursor.
Note3: The Main Group No.1 to No.997 are available for PLU programming.

22

SM 110

PROGRAM MODE
(No.997 is default No. for PLU programming, and the PLUs which are not linked to any Main Group No. are
assigned to No.997)
(Non-PLU files (Weighing items) are assigned to Main Group code No.998)
(Non-PLU files (Non-weighing items) are assigned to Main Group code No.999)

Note4: The Main Group names programmed are not printed on the label/receipt but are for reporting.
Note5: Each Main Group No. must be linked to the exiting Dept. No.(Refer to 3.3 Department File).

3.4.2 Delete Main Group File
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S3

→

MGROUP

FILE

[*]

S3.0

MG

0

NO SET

[1][1][1]

S3.0

MG

111

NO SET

[-]

S3.0

MG

DEL ?

Y-C N-T

[C]

S3

→

MGROUP

FILE

[MODE][MODE]
[MODE]
[3] or [》]

REMARK
Enter S mode.
Lamp S turns on.
Select Main Group Programming
and
Enter it.
Enter Main Group No.
(Ex. [1][1][1])
[C] for Yes, [T] for No.
Delete M.G. file 111,back to S
mode.

Note1: When the PLU FILE exists under the Main Group File, the Main Group Number cannot be deleted. In
addition, the Main Group Number 997, 998 and 999 cannot be deleted.

23

SM 110

PROGRAM MODE

3.5 Program / Skip Item Data
Unnecessary PLU parameters will be skipped automatically due to auto-skip function, it is possible to
set only necessary PLU parameter in PLU programming procedure "Program PLU File". The following
parameters are available for Program/ Skip function
Display

No.

Parameter

Symbol

1

[LABFR1]

1. Label format 1

LABFR1

2

[LABFR2]

2. Label format 2

LABFR2

3

[BACODE]

3. Barcode Selection

BACODE

4

[FLAG]

4. Barcode Flag data

FLAG

5

[ITCODE]

5. Barcode Item Code

ITCODE

6

[MGCODE]

6. Main Group Code

MGCODE

7

[SELLDT]

7. Sell by Date

SELLDT

8

[SELLTM]

8. Sell by Time

SELLTM

9

[USEDDT]

9. Used by Date

USEDDT

10

[PACKDT]

10. Packed Date

PACKDT

11

[PACKTM]

11. Packed Time

PACKTM

12

[COST]

12. Cost

COST

13

[TARE]

13. Tare

TARE

14

[QTY]

14. Quantity

QTY

15

[Q.UNIT]

15. Quantity Unit

QUNIT

16

[DISCNT]

16. Discount Status

DISCNT

17

[SCH DT]

17. Discount Schedule date

SCHDT

18

[SCH TM]

18. Discount Schedule time

SCHTM

19

[MARKDN]

19. Mark Down Status

MARKDN

20

[1STLMT]

20. 1st target for discount 1

FSTLMT

21

[2NDLMT]

21. 2nd target for discount 2

SNDLMT

22

[SMGNUM]

22. Special Message #

SMGNUM

23

[INGNUM]

23. Ingredients #

INGNUM

24

[COMNAM]

24. Commodity Name

COMNAM

25

[SP

25. Special Message

SPMG

26

[INGR]

26. Ingredients

INGR

27

[PLCNUM]

27. Place of Production

PLCNUM

28

[IMAGE]

28. Image

IMAGE

29

[BONUS]

29. Bonus

BONUS

30

[NUTRI]

30. Nutrition

NUTRI

31

[ITFSEL]

31. ITF Selection

ITFSEL

32

[REFPLU]

32. Reference PLU No.

REFPLU

33

[SECPLU]

33. Security PLU

SECPLU

34

[COUPLU]

34. Coupled PLU

COUPLU

MG]

24

SM 110

PROGRAM MODE

Display

No.

Parameter

Symbol

35

[DAY WK]

35. Discount day of the week

DAYWK

36

[ADD-ON]

36. EAN 5 Digit ADD-ON

ADDON

37

[TAX]

37. TAX No.

TAX

38

[PRICE2]

38. 2nd Price

PRICE2

39

[%

39. Proportional Tare

PROTARE

40

[CUSDIS]

40. Customer Discount

CUSDIS

41

[RESDIS]

41. Restaurant Discount

RESDIS

42

[STADIS]

42. Staff Discount

STADIS

43

[TRACE]

43. Traceability Discount

TRACE

44

[TEMP]

44. Storage Temperature

TEMP

45

[PACK.I]

45. Pack. Indicator

PACKI

46

[M1BARC]

46. Multi Barcode 1

M1BARC

47

[M2BARC]

47. Multi Barcode 2

M2BARC

48

[TM1BAR]

48. Total Multi Barcode 1

TM1BAR

49

[TM2BAR]

49. Total Multi Barcode 2

TM2BAR

50

[U.PRIC]

50. Unit Price Selection

UPRIC

51

[PLUSCR]

51. PLU Scroll (U1 only)

PLUSCR

52

[PLUTEX]

52. PLU Linked Text Field

PLUTEX

TARE]

Program/Skip Item Data
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S19

→

PLU

ITEM

[*]

S19.1

ITEM

[*][*][*][*][*]

S19.1

ITEM

[X]

S19.1
S19

[MODE][MODE]
[MODE]
[1][9] or [》]

[PLU]

REMARK
Enter S mode.
Lamp S turns on.
Select PLU item Selection Mode
and enter

PROGRAM

Enter Program or Skip parameter
selection mode.

MGCODE

SKIP

Select parameter of Main Group.

ITEM

MGCODE

PROGRAM

→

PLU

ITEM

LABFR1

Select

PROGRAM

for

the

parameter of Main Group.
After finish setting, save it.
Back to S mode.

Note1: Press [*] key to next parameter or [−] key to previous parameter and press [X] key to select PROGRAM or
SKIP for each parameter, if necessary.
Note2: If you want to exit without saving, press [◇] key follow by [C] key.

25

SM 110

PROGRAM MODE

3.6 PLU Programming
The following items can be programmed in PLU PROGRAMMING mode. The format chosen for the
PLU will decide what items can be programmed in the PLU file. The items which print areas are not set
on the selected format will skip automatically or not printed on label. (If the item doesn't appear on the
PLU programming, check whether the parameter is set to ENABLE in Program / Skip Item Data).
PLU file for weighing item and non-weighing item listed below can be programmed according to the
following order.
Weighing Item
Step

PLU File (weighing Item)

Remarks

S1.0

PLU No.

S1.1

Unit Price (6 digits)

S1.2

Label Format for the 1st label

Refer to Label Format List.

S1.3

Label Format for the 2nd label

Free format No.1~99 only.

S1.4

Commodity Name Font Size

S1.4

Commodity Name

S1.5

Selection of ITF Barcode Format

S1.6

Bar Code Selection

S1.7

Flag data

S1.8

Item Code No.

* Digits of Flag and Item data can be selected in the barcode type
selection in S1.6.

S1.9

Item Code No. (Lower 4 digits)

Only when Item Code is more than 6 digits.

S1.10

Right Side Data of Item Barcode

Only when Spec02 set to 3.

S1.11

Selection of EAN ADD-ON

S1.12

Main Group No.

S1.13

Select whether to print Sell by date

S1.14

Sell by date (Days after the current date)

S1.15

Select whether to print Sell by time

S1.16

Select key-in data or present time

S1.17

Sell by Time (If Key-In is selected)

S1.18

Select whether to print Used by date

S1.19

Used by date (days after Packed date)

S1.20

Select whether to print Packed date

S1.21

Packed Date (days after actual packed date)

S1.22

Select whether to print Packed time

* If No Print is selected, Sell- by Date in S1.12 is skipped.
* If No Print is selected, Key in selection in S1.14 Sell-by time in
S1.15 is skipped.
* If S1.14 select CLOCK TIME, Key in selection in S1.15 is
skipped.
* If No Print is selected, Used- by Date in S1.17 is skipped.
* If No Print is selected, Packed Date in S1.19 is skipped.

* If No Print is selected, Key-in selection in S1.21 Packed time in
S1.22 are skipped.

26

SM 110

Step

PROGRAM MODE

PLU File (weighing Item)

Remarks

S1.23

Select to print Key-In data or actual time

S1.24

Packed Time (if key-In is selected)

S1.25

Cost price

S1.26

PLU Tare

* Depends on SPEC: 647 SETTING.

S1.29

Type of Volume Discount

* Depends on SPEC: 100 SETTING.

S1.30

The 1st target of volume discount

S1.31

The discount value for the 1st target

S1.32

The 2nd target of volume discount

S1.33

The discount value for the 2nd target

S1.34

Print type of Discount price (Mark Down)

S1.35

Schedule of Volume Discount (The start date)

S1.36

Schedule of Volume Discount (The start time)

S1.37

Schedule of Volume Discount (The end date)

S1.38

Schedule of Volume Discount (The end time)

S1.39

S1.41

Selection of Discount Day of The Week.
Special message No. (Select No. from SP message
file)
Ingredient No. (Select No. from Ingredient file)

S1.42

Special message (Program original Special Message)

S1.43

Ingredient (Program original Ingredient)

S1.44

Place of production (Select No. from Place file)

S1.45

Coupled PLU Number

S1.46

TAX Number (Select Number from TAX File)

S1.47

Reference PLU Number

S1.48

Proportional Tare

S1.40

* If S1.21 select CLOCK TIME, Key in selection in S1.22 is
skipped.

* If No Volume discount is selected, the parameters in S1.27 ~
S1.36 are skipped.
*Entering by Number keys (0~3)

* If selected Label Format without PRINT AREA, S1.40 ~
S1.43 are skipped.

* If selected Label Format without PRINT AREA, the
PLACE message will print on 1st line of Commodity Name.

*Depend on SPEC: 603 SETTING.
*Depend on SPEC: 687 SETTING.

27

SM 110

PROGRAM MODE

Non-Weighing Item
Step

PLU File (Non-weighing Item)

Remarks

S1.0

PLU No.

S1.1

Unit Price (6 digits)

S1.2

Label Format for the 1st label

Refer to Label Format List.

S1.3

Label Format for the 2nd label

Free format No.1~99 only.

S1.4

Commodity Name Font Size

S1.4

Commodity Name

S1.5

Selection of ITF Barcode Format

S1.6

Bar Code Selection

S1.7

Flag data

S1.8

Item Code No.

* Digits of Flag and Item data can be selected in the barcode type
selection in S1.6.

S1.9

Item Code No. (Lower 4 digits)

Only when Item Code is more than 6 digits.

S1.10

Right Side Data of Item Barcode

Only when Spec02 set to 3.

S1.11

Selection of EAN ADD-ON

S1.12

Main Group No.

S1.13

Select whether to print Sell by date

S1.14

Sell by date (Days after the current date)

S1.15

Select whether to print Sell by time

S1.16

Select key-in data or present time

S1.17

Sell by Time (If Key-In is selected)

S1.18

Select whether to print Used by date

S1.19

Used by date (days after Packed date)

S1.20

Select whether to print Packed date

S1.21

Packed Date (days after actual packed date)

S1.22

Select whether to print Packed time

S1.23

Select to print Key-In data or actual time

S1.24

Packed Time (if key-In is selected)

S1.25

Cost price

S1.27

Unit Symbol (PCS / FOR / kg / lb / g / NO
SYMBOL)

S1.28

Quantity

S1.29

Type of Volume Discount

* If No Print is selected, Sell- by Date in S1.12 is skipped.
* If No Print is selected, Key in selection in S1.14 Sell-by time in
S1.15 is skipped.
* If S1.14 select CLOCK TIME, Key in selection in S1.15 is
skipped.
* If No Print is selected, Used- by Date in S1.17 is skipped.
* If No Print is selected, Packed Date in S1.19 is skipped.
* If No Print is selected, Key-in selection in S1.21 Packed time in
S1.22 are skipped.
* If S1.21 select CLOCK TIME, Key in selection in S1.22 is
skipped.

* Depends on SPEC: 100 SETTING.

28

SM 110

PROGRAM MODE

Step

PLU File (Non-weighing Item)
1st

Remarks

S1.30

The

target of volume discount

S1.31

The discount value for the 1st target

S1.32

The 2nd target of volume discount

S1.33

The discount value for the 2nd target

S1.34

Print type of Discount price (Mark Down)

S1.35

Schedule of Volume Discount (The start date)

S1.36

Schedule of Volume Discount (The start time)

S1.37

Schedule of Volume Discount (The end date)

S1.38

Schedule of Volume Discount (The end time)

S1.39

Selection of Discount Day of The Week.

S1.40

Special message No. (Select No. from SP message
file)

S1.41

Ingredient No. (Select No. from Ingredient file)

S1.42

Special message (Program original Special
Message)

S1.43

Ingredient (Program original Ingredient)

S1.44

Place of production (Select No. from Place file)

S1.45

Coupled PLU Number

S1.46

TAX Number (Select Number from TAX File)

S1.47

Reference PLU Number

* If No Volume discount is selected, the parameters in S1.27 ~
S1.36 are skipped.

*Entering by Number keys (0~3)

* If selected Label Format without PRINT AREA, S1.40 ~
S1.43 are skipped.

* If selected Label Format without PRINT AREA, the PLACE
message will print on 1st line of Commodity Name.

*Depend on SPEC: 603 SETTING.

29

SM 110

PROGRAM MODE

3.6.1 Program PLU File(weighing item)
PLU data(weighing item) is programmed by following procedure as below.
If the selected 1st or 2nd label format does not have print area for the PLU items, the item will be skipped
automatically or not printed on label.

OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

[*]

S1.0

PLU

0

NO SET

[1][0][0]

S1.0

PLU

100

NO SET

[*]

S1.1

PLU

0.00

PR-KG

[MODE][MODE]
[MODE]

REMARK
Enter S mode.
Lamp S turns on.
Enter PLU programming mode.
$/kg window displays PLU number.
Enter new PLU Number (Ex. 100) you want.
Enter PLU programming.
Enter unit price.(Ex.5.80$/kg)
Select Label format for 1st Label by press [<<]

[5][8][0][*]

S1.2

PLU

DFT

0

LAB FR1

or [>>] key.
(T1~T12,S,A,B,C,F1~F8 is available)

[<<] or [>>]

S1.2

PLU

T6

6

LAB FR1

Set the Label format (Ex.T6) by press [6] or[>>]
key.
Select Label format for 2nd Label by press [<<]

[*]

S1.3

PLU

NO

0

LAB FR2

or [>>]key.
(F1~F8 only)

[<<] or [>>]

S1.4

C01.01

S1 A 100

Enter commodity name.(Ex. “SLICE”)

S1.4

C02.01

S1 A 100

Enter the 2nd line of commodity name.

[*]

S1.5

PLU

EAN

BARCODE

[*]

S1.6

PLU

DFLT

BARCODE

[*]
[S][L][I][C][E]
[*]

Select the type of BARCODE by press [X] or
[>>].(EAN or ITF)
Select barcode format by press [<<] or [>>]
key.(Ex.2f5c4i4wD)
Set flag data.(Ex.29)

[<<] or [>>]
[*]

S1.7

PLU

20

FLAG

The Default Flag Data can be set at SPEC 3 ~ 6
and the Flag data consists of one or two digits,
which depends on the selected Barcode type.

[2][9]
[*]

S1.8

PLU

00000

IT CODE

30

Enter item code.(Ex.10010)

SM 110

OPERATION
[1][0][0][1][0]
[*]
[*]

PROGRAM MODE
DISPLAY
PT

kg

$/kg

$

S1.9

PLU

00000

EX CODE

S1.10

PLU

EAN

REMARK
No appended item code of PLU 100.

ADD

Select EAN ADD-ON or EAN ADD-OFF.(Ex.

OFF

EAN ADD-OFF)
Set the Main Group number.(default MG 997)

[*]

S1.12

PLU

997

MG NO

Enter Main Group No.(Ex.111)
Link PLU 100 to Main Group 111.

[1][1][1]
[*]
[<<] or [>>]
[*]
[3]
[*]

Press [<<] or [>>] key to change whether print
S1.13

PLU

NPRINT

SELL DT

sell-by-date.
(Ex. Print sell by date)

S1.14

PLU

0

SELL DT

Set sell-by-date.(Ex.3 days)
3 digits can be set.(0~999)
Press [<<] or [>>] key to change whether print

S1.15

PLU

NPRINT

SELL TM

sell-by-time.
(Ex. No print sell by time)
Press [<<] or [>>] key to change whether print

[*]

S1.18

PLU

NPRINT

USED DT

used by date.
(Ex. No print used by date)

Set used-by-date,
used-by-time
[*]
[<<] or [>>]
[*]
[1][*]
[<<] or [>>]
[*]
[<<] or [>>]
[*]
[1][8][0][0]
[*]
[*]

…

…

…

…

S1.20

PLU

NPRINT

PACK DT

Setting way of used-by-date, used-by-time are
same as setting sell-by-date and sell-by-time.
Press [<<] or [>>] key to change whether print
packed date.
If necessarily, packed date can set the day after

S1.21

PLU

0

PACK DT

present date.
(Ex. 1 day after present day)

S1.22

PLU

NPRINT

PACK TM

S1.23

PLU

TIME

PRESENT

S1.24

PLU

0000

PACK TM

S1.25

PLU

0.00

COST

S1.26

PLU

0.000

TARE

31

Press [<<] or [>>] key to change whether print
packed time.
Press [<<] or [>>] key to change key-in time or
present time.
Set the packed time.
(Ex. 18:00)

Enter Preset Tare of PLU 10.(Ex.0.100kg)

SM 110

OPERATION
[1][0][0]
[*]

[*]
[1][0][0]
[*]
[3][0]
[*]
[1][0][0][0]
[*]
[5][0]

[<<] or [>>]
[*]
[1][0][0][1][0][4]
[*]
[0][9][0][0]
[*]
[1][1][0][1][0][4]
[*]
[0][9][0][0]

[1]
[PLU]

PT

kg

$/kg

REMARK

$

6 kinds discount type can be selected by press
S1.29

PLU

NO

DISCONT

[<<] or [>>] key.

S1.30

PLU

0.000

1ST LMT

Set 1st limit weight is 0.1kg.(Ex.0.100kg)

S1.31

PLU

0.00

1ST AMT

Set 1st amount of discount is $0.30.

S1.32

PLU

99.999

2ND LMT

Set 2nd limit weight is 1.000kg.

S1.33

PLU

0.00

2ND AMT

Set 2nd amount of discount is $0.50.

S1.34

[*]

[1][*]

DISPLAY

(Ex. UNIT PRICE discount)

[<<] or [>>]

[*]

PROGRAM MODE

PLU

NO

MARK
DOWN

Change selection by [<<] or [>>]:
No mark down/Unit price mark down
/Total price mark down/all mark down
Set

discount

start

day.(Ex.10-01-04,

S1.35

PLU

000000

ST DATE

S1.36

PLU

0000

ST TIME

Set discount start time.(Ex. 09:00, HH-MM)

S1.37

PLU

000000

ED DATE

Set

S1.38

PLU

0000

ED TIME

Set discount end time.(Ex. 09:00)

S1.40

PLU

0

SMG NUM

S1.41

PLU

0

ING NUM

S1

→

PLU

ITEM

MM-DD-YY)

discount end date.(Ex.11-01-04)

Set special message file number.(Ex. Number 1)
Special message file 1 is linked to this PLU.
Set ingredients file number.(Ex. Number 1)
Ingredients file 1 is linked to this PLU.
After finish setting, save it.
Back to S mode.

Note1: Press [*] key to next parameter or [−] key to previous parameter.
Note2: The letter before "A" in Total Price display shows the letter font size of the commodity name, and the number
after "A" in Total Price display shows the number of letters can be programmed for commodity name.

32

SM 110

PROGRAM MODE

Note3: The 2 digits after "C" in Weight display shows the line of the commodity name, and the next 2 digits in Weight
display shows the position of the cursor.
Note4: The PLU No.1 to No.999999 are available for PLU programming.
Note5: The programmed PLU commodity name are printed on the label or receipt.
Note6: Max.100 letters for commodity name per file are available.
Note7: Each PLU No. must be linked to the exiting Main Group No.(Refer to 3.4 Main Group File).

3.6.2 Program PLU File(non-weighing item)
PLU data(non-weighing item) is programmed by following procedure as below.
*If the selected 1st or 2nd label format does not have print area for the PLU items, the item will be skipped
automatically or not printed on label
OPERATION
[MODE][MODE]
[MODE]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

REMARK
Enter S mode.
Lamp S turns on.
Enter PLU programming mode.

[*]

S1.0

PLU

0

NO SET

$ /kg window displays PLU
number.

[2][0][0]

S1.0

PLU

200

NO SET

[*]

S1.1

PLU

0.00

PR-KG

S1.1

PLU

5.80

PR-PCS

[<<] or [>>]
[5][8][0]

Enter new PLU Number (Ex. 200)
you want.
Enter PLU programming.
Enter unit price.(Ex.5.80$/kg)
Change Unit price of PLU 200 to
non-weighing item.
Select Label format for 1st Label by

[*]

S1.2

PLU

DFT

0

LAB FR1

press [<<] or [>>] key.
(T1~T12,S,A,B,C,F1~F8

is

available)
[<<] or [>>]

S1.2

PLU

T6

6

LAB FR1

Set the Label format (Ex.T6) by
press [6] or[>>] key.
Select Label format for 2nd Label

[*]

S1.3

PLU

NO

0

LAB FR2

by press [<<] or [>>]key.
(F1~F8 only)

[<<] or [>>]
[*]

S1.4

C01.01

S1 A 100

33

Enter

commodity

“CAKE”)

name.(Ex.

SM 110

OPERATION

PROGRAM MODE
DISPLAY

REMARK

PT

kg

S1.4

C02.01

[*]

S1.5

PLU

EAN

BARCODE

[*]

S1.6

PLU

DFLT

BARCODE

[C][A][K][E]
[*]

$/kg

$
S1 A 100

Enter the 2nd line of commٛ ddity
name.
Select the type of BARCODE by
press [X] or [>>].(EAN or ITF)
Select barcode format by press
[<<] or [>>] key.(Ex.2f5c4i4wD)
Set flag data.(Ex.29)
The Default Flag Data can be set at

[<<] or [>>]
[*]

S1.7

PLU

20

FLAG

SPEC 3 ~ 6 and the Flag data
consists of one or two digits, which
depends on the selected Barcode
type.

[2][9]
[*]
[2][0][0][2][0]
[*]
[*]

S1.8

PLU

00000

IT CODE

S1.9

PLU

00000

EX CODE

S1.10

PLU

EAN

ADD

OFF

Enter item code.(Ex.20020)
No appended item code of PLU
100.
Select EAN ADD-ON or EAN
ADD-OFF.(Ex. EAN ADD-OFF)
Set

[*]

S1.12

PLU

997

MG NO

the

Main

Group

number.(default MG 997)
Enter Main Group No.(Ex.222)
Link PLU 200 to Main Group 222.

[2][2][2]
[*]
[<<] or [>>]
[*]
[3]
[*]
[*]
Set used-by-date,
used-by-time

Press [<<] or [>>] key to change
S1.13

PLU

NPRINT

SELL DT

whether print sell-by-date.
(Ex. Print sell by date)

S1.14

PLU

0

SELL DT

Set sell-by-date.(Ex.3 days)
3 digits can be set.(0~999)
Press [<<] or [>>] key to change

S1.15

PLU

NPRINT

SELL TM

whether print sell-by-time.
(Ex. No print sell by time)

S1.18

PLU

NPRINT

USED DT

Press [<<] or [>>] key to change
whether print used by date.
Setting

…

…

…

…

way

of

used-by-date,

used-by-time are same as setting
sell-by-date and sell-by-time.

34

SM 110

OPERATION
[*]
[<<] or [>>]
[*]
[1][*]
[<<] or [>>]
[*]
[<<] or [>>]
[*]
[1][8][0][0]
[*]

PROGRAM MODE
DISPLAY
PT

kg

$/kg

$

S1.20

PLU

NPRINT

PACK DT

REMARK
Press [<<] or [>>] key to change
whether print packed date.
If necessarily, packed date can set

S1.21

PLU

0

PACK DT

the day after present date.
(Ex. 1 day after present day)

S1.22

PLU

NPRINT

PACK TM

S1.23

PLU

TIME

PRESENT

S1.24

PLU

0000

PACK TM

S1.25

PLU

0.00

COST

Press [<<] or [>>] key to change
whether print packed time.
Press [<<] or [>>] key to change
key-in time or present time.
Set the packed time.
(Ex. 18:00)

Press [<<] or [>>] to select unit
[*]

S1.27

PLU

PCS

USYMBOL

symbol.
Selection: PCS/FOR/kg/lb/g/NO

[<<] or [>>]
[*]
[1][0]
[*]

S1.28

PLU

0

QTY

4 digits can be set.(0~9999).
(Ex. 10 pcs/PLU)
6 kinds discount type can be

S1.29

PLU

NO

DISCONT

selected by press [<<] or [>>] key.
(Ex. UNIT PRICE discount)
Change selection by [<<] or [>>]:

[<<] or [>>]
[*]

No mark down/Unit price mark
S1.34

PLU

NO

MARK DOWN

down
/Total price mark down/all mark
down

[<<] or [>>]
[*]
[1][0][0][1][0][4]
[*]
[0][9][0][0]
[*]

S1.35

PLU

000000

ST DATE

S1.36

PLU

0000

ST TIME

S1.37

PLU

000000

ED DATE

35

Set discount start day.(Ex.10-01-04,
MM-DD-YY)
Set discount start time.(Ex. 09:00,
HH-MM)
Set

discount

date.(Ex.11-01-04)

end

SM 110

OPERATION
[1][1][0][1][0][4]
[*]

PROGRAM MODE
DISPLAY
PT

kg

$/kg

$

S1.38

PLU

0000

ED TIME

REMARK

Set discount end time.(Ex. 09:00)
Set

[0][9][0][0]
[*]

S1.40

PLU

0

SMG NUM

special

message

file

number.(Ex. Number 1)
Special message file 1 is linked to
this PLU.
Set ingredients file number.(Ex.

[1][*]

S1.41

PLU

0

ING NUM

Number 1)
Ingredients file 1 is linked to this
PLU.

[1]
[PLU]

S1

→

PLU

ITEM

After finish setting, save it.
Back to S mode.

Note1: Press [*] key to next parameter or [−] key to previous parameter.
Note2: The letter before "A" in Total Price display shows the letter font size of the commodity name, and the number
after "A" in Total Price display shows the number of letters can be programmed for commodity name.
Note3: The 2 digits after "C" in Weight display shows the line of the commodity name, and the next 2 digits in Weight
display shows the position of the cursor.
Note4: The PLU No.1 to No.999999 are available for PLU programming.
Note5: The programmed PLU commodity name are printed on the label or receipt.
Note6: Max.100 letters for commodity name per file are available.
Note7: Each PLU No. must be linked to the exiting Main Group No.(Refer to 3.4 Main Group File).

36

SM 110

PROGRAM MODE

3.6.3 PLU [COPY] Function
The programmed PLU data can be easily copied into a new PLU. The function is very useful to save
time or avoid mistake for the similar PLU data programming, especially in case of long description of
Ingredients.
Example: PLU No.124 is programmed with most data of the PLU No. 100 already in memory.
DISPLAY

OPERATION

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

[*]

S1.0

PLU

0

NO SET

[1][2][4]

S1.1

PLU

124

NO SET

Select PLU 124,enter PLU programming.

[X]

S1.1

PLU

0

COPY

Press [X] key to enter PLU copy function.

S1.1

PLU

5.80

PR-KG

Copy PLU 100 data to PLU 124.

S1.2

PLU

T6

[*]

S1.3

PLU

NO

0 LAB FR2

[*]

S1.4

C01.01

SLICE

S1 A 95

S1.8

PLU

10100

IT CODE

[1][0][1][2][4]

S1.8

PLU

10124

IT CODE

[*]

S1.9

PLU

00000

EX CODE

S1

→

PLU

FILE

[MODE][MODE]
[MODE]

[1][0][0]
[*]
[4][8][0]
[*]

Press [*] key
times

[PLU]

5

6

LAB FR1

37

Enter S mode.
Lamp S turns on.
Enter PLU programming mode.
$/kg window displays PLU number.

Unit price of PLU 124 is 4.80$/kg.
The 1st Label format is T6.
Commodity Name of PLU 124 is “SLICE”.
Item code of PLU 124 is 10124.

Store the PLU 124 file, back to S mode.

SM 110

PROGRAM MODE

3.6.4 Delete PLU File
OPERATION
[MODE][MODE]
[MODE]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

REMARK
Enter S mode.
Lamp S turns on.
Enter PLU programming mode.

[*]

S1.0

PLU

0

NO SET

$ /kg window displays PLU
number.

[1][2][4]

S1.0

PLU

124

NO SET

[-]

S1.0

PLU

DEL ?

Y-C N-T

[C]

S1

→

PLU

FILE

Select PLU 124.(Ex. Delete PLU
No.124)
Press [-] key to delete PLU 124.
[C] for Yes, [T] for No.
Delete PLU file No.124, back to S
mode.

Note1: Only the programmed PLU file can be deleted.
Note2: In the last operation, pressing [T] key can back to the S Mode without deleting PLU file 124.

38

SM 110

PROGRAM MODE

3.6.5 Volume Discount & Mark Down print function
Volume Discount function is used to set up special price during a sales period. Shop manager may
program the discount price during a sales period, and the Shop manager can avoid sales loss caused by
not returning the discount price back to the original price even after the sales period.
Type of Volume Discount
Shop manager can select a discount type from 5 types of volume discount. The formulas of 5 discount
type are shown in the following table.
Formula of Discount price
Discount Type
Free Item

Formula

Example

Price = 0

Total Price = 0

(1) Unit Price = Original Unit Price Unit Price discount amount.

Original Unit Price = $ 10.00

™ To called up PLU with 0
Unit Price and allow
issuing a receipt or label,
SPEC 231 must set to
"ALLOW" in advance.
Unit Price Discount
™ To select Formula (1) or
Formula (2) can be
decided by SPEC 124
Setting.
Unit Price % Discount

(2) Unit Price = Unit Price discount
amount.

Unit Price discount amount = $2.00
(1) Unit Price = $10.00 - $2.00 = $8.00
(2) Unit Price = $2.00

Unit Price = Original Unit Price x
(100% - % Discount)

Original Unit Price = $ 10.00
% Discount = 20%
Unit Price = $10.00 x (100% - 20%) = $8.00

Total Price Discount

Total Price = Original Price - Price
Discount Amount

Original Total Price = $10.00
Price Discount Amount = $2.00
Total Price = $10.00 - $2.00 = $8.00

Total Price % Discount

Total Price = Original Total Price x
(100% - % Discount)

Original Total Price = $10.00
% Discount = 20%
Total Price = $10.00 x (100% - 20%) = $8.00

Fixed Price Discount

Total Price = Fixed Price Amount

Original Total Price = $10.00
Fixed Price Amount = $8.00
Total Price = $8.00

39

SM 110

PROGRAM MODE

Mark Down Print Function (How to print discount price)
Mark Down Print function is used to print the discount price as well as the original price with double
lines crossed when item is discounted. Mark Down Print function can be selected from the following
4 types, No Mark down / Unit Price Mark down/ Price Mark down / Unit Price & Price Mark down.
Type of Sales price function

Description of Sales Price data on label
Unit Price

No Mark Down
Unit Price Mark Down

Total Price

$1.50

$

$15.00
2.00

$15.00

1.50
Total Price Mark Down
Unit & Total Price Mark Down

$1.50

$

Refer to Note 1
2.00

$
$

1.50

20.00
15.00
20.00
15.00

Note 1: Since discount unit price cannot be calculated if Total Price discount is used, it is not able to use Unit Price
Mark Down function, when using Total Price discount and Free item discount.

40

SM 110

PROGRAM MODE

3.7 Memory Status
The function is used for checking the number of existing PLU and remaining programmable PLU.
OPERATION
[MODE][MODE]
[MODE]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

REMARK
Enter S mode.
Lamp S turns on.
Select memory status check mode.

[2][0]

S20

→

MEMORY

STATUS

You can press [《] or [》] key to
select this mode.

[*]

S20.0

PLU

[T]

S20

→

P

7

MEMORY

41

LF 4544
STATUS

Back to S mode.

SM 110

PROGRAM MODE

3.8 Key Assignment
The Preset keys can be used for assignment of PLUs and Function keys to speed up the operation in R
mode.

3.8.1 PLU Assignment
PLU Number can be assigned to a preset key to call up PLU data by pressing the assigned preset key on
Registration Mode.

For example: Assign PLU Number 100 to Preset Key Number 1.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

S4

→

KEY

ASSIGNMENT

[*]

S4.0

PS AS

0

NO SET

Enter PLU assignment mode.

[1][0][0]

S4.0

PS AS

100

NO SET

Enter PLU No.100

[PRESET 1]

S4.0

PS AS

0

NO SET

S4

→

KEY

ASSIGNMENT

[MODE][MODE]
[MODE]
[4] or [》] three times

[◇][C]

Enter S mode.
Lamp S turns on.
Key Assignment mode is MENU 4
in S mode.

PLU No.100 had been assigned to
Preset Key 1.
Back to S mode.

Note1: Non-existing PLU No. can not be assigned.
Note2: If assigning PLU Number 50 to the Preset key No. 1 has been already programmed, the PLU No. 50 will
replace the old data of Preset Key No. 1, but PLU Number cannot replace the preset key are already assign for
Function Key, Vender Key or Preset Tare.

3.8.2 Function Key Assignment
By assigning the following function keys to Preset keys, the functions can be used by touching the assigned
keys
OPERATION
[MODE][MODE]
[MODE]
[4] or [》] three times
[*]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S4

→

KEY

ASSIGNMENT

S4.0

PS AS

0

NO SET

42

REMARK
Enter S mode.
Lamp S turns on.
Key Assignment mode is MENU 4
in S mode.
Enter PLU assignment mode.

SM 110

OPERATION

PROGRAM MODE
DISPLAY
PT

kg

$/kg

$

[*]

S4.1

VR AS

0

NO SET

[*]

S4.2

FN AS

0

CLEAR

[X][X]

S4.0

FN AS

2

-PRICE

REMARK
Enter Vender Key assignment status.
Enter Function Key assignment
status.
Select PRICE DISCOUNT function
PRICE DISCOUNT function had

[PRESET 25]

S4.2

FN AS

0

CLEAR

been assigned to Preset Key number
25.

[◇][C]

S4

KEY

→

ASSIGNMENT

Back to S mode.

Note1: Non assigned Preset Key can be set as function key.

3.8.3 Delete Preset Key Assignment
The following operation as below is to delete the Preset Key Assignment for PLU preset key, Function
Key and Vender key.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S4

→

KEY

ASSIGNMENT

[*]

S4.0

PS AS

0

NO SET

[*]

S4.2

FN AS

0

CLEAR

[PRESET 25]

S4.0

FN AS

DEL ?

Y-C N-T

[C]

S4.0

FN AS

0

CLEAR

S4

→

KEY

ASSIGNMENT

[MODE][MODE]
[MODE]
[4] or [》] three times

[◇][C]

REMARK
Enter S mode.
Lamp S turns on.
Key Assignment mode is MENU 4
in S mode.
Enter PLU assignment mode.
Enter Function Key assignment
status.
Enter deleting mode.
[C] for Yes, [T] for No.
Back to S mode.

Note1: Non assigned Preset Key can not be cleared.
Note2: In the last operation, pressing [T] key can back to Assigned key clear mode and do not clear the assigned key

43

SM 110

PROGRAM MODE

3.9 Shop Name File
Shop Name data will be printed on Label or Receipt can be programmed in this file. The maximum
number of characters possible to enter varies according to the size of print area or character size entry. Up
to 32 Shop Names can be programmed with each 3 lines as maximum and number of line is depends on
the Character Size entry.
The default Shop Name print on label can be set at SPEC 46 & print centering of shop name on label can
be select at SPEC 250 and default Shop Name print on Receipt can be set at SPEC47 & printing position
can be select at SPEC251.

3.9.1 Program Shop Name File
At Programming Mode, select Shop Name programming mode and then enter new Shop Name
number (Ex. 1) programming mode.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S5

→

SHOP

NAME FILE

[*]

S5.0

SHOP

0

NO SET

[1][*]

S5.1

S01.01

[MODE][MODE]
[MODE]
[5] or [》] four times

S1 A 100

REMARK
Enter S mode.
Lamp S turns on.
Shop name File mode is MENU 5
in S mode.
Enter

Shop

Name

File

programming mode.
Enter shop name code.(Ex.No.1)
Press [SIZE] key to change font

[SIZE][D][I][G][I][SP
][S][H][O][P]

S5.1

S01.10

SHOP

S2 A 76

size of the shop name.
Enter the shop name .(Ex. “DIGI
SHOP”)

[*]

S5.1

S02.01

S1 A 100

[T][E][L][:]……

S5.1

S02.13

S1 A 88

S5

→

[PLU]

SHOP

NAME FILE

44

Program 2nd line of this shop
name.
Enter shop name for the 2nd
line.(Ex. “TEL:57234888”)
Store Shop Name File 1,Back to S
mode.

SM 110

PROGRAM MODE

3.9.2 Delete Shop Name File
At Shop Name programming mode, enter existing Shop Name Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S5

→

SHOP

NAME FILE

[*]

S5.0

SHOP

0

NO SET

[1]

S5.0

SHOP

1

NO SET

[-]

S5.0

SHOP

DEL ?

Y-C N-T

[C]

S5

→

SHOP

NAME FILE

[MODE][MODE]
[MODE]
[5] or [》] four times

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2:

Non-existing Shop Name File can not be deleted.

45

REMARK
Enter S mode.
Lamp S turns on.
Shop name File mode is MENU 5
in S mode.
Enter

Shop

Name

File

programming mode.
Enter shop name file 1.(Ex. No.1)
Enter deleting mode.
[C] for Yes, [T] for No.
Delete Shop Name File 1,back to S
mode.

SM 110

PROGRAM MODE

3.10 Advertisement File
Advertisement message is the sales promotional description on the label, such as “FOR BARBECUE”
or “FRESH”. Advertisement message is printed in the print area of the Commodity Name. If
Commodity Name occupies all of the print area, there will be no room for the Advertisement Message
and it will therefore not be printed. Maximum 2 lines can be programmed for each Advertisement
Message and up to 64 (Advertisement # 1~64) advertisement messages are available.
To print advertisement message on a label, [ADVERTISEMENT] Function Key must be assigned to
a preset key in advance.
Note: Advertisement message print on all label can be set at SPEC 96, printing position can be set at
SPEC 14 and printing method can be set at SPEC 15.

3.10.1 Program Advertisement File
At Programming Mode, select Advertisement programming mode and then enter new Advertisement
number (Ex. 1) programming mode.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S6

→

ADVER

MESSAGE

[*]

S6.0

ADVER

0

NO SET

[1][*]

S6.1

A01.01

[MODE][MODE]
[MODE]
[6] or [》] five times

[T][H][A][N][K][SP]
[Y][O][U]

S1 A 100

Enter S mode.
Lamp S turns on.
Select

advertisement

file

programming

mode.
Enter advertisement File programming
mode.
Enter the advertisement File No.1(Ex.No.1)
Enter the advertisement as the same

S6.1

A01.10

K YOU

S1 A 91

procedures as Commodity Name Entry.
(Ex. “THANK YOU”)

[SIZE]

S6.1

A01.10

K YOU

S2 A 76

[SIZE]…[SIZE]

S6.1

A01.10

K YOU

L5 A 21

[*]

S6.1

A02.01

S6

→

[PLU]

REMARK

ADVER

Press [SIZE] key to change font size of the
advertisement file.
Change font size to L5.
(S1~S5; M1~M5; L1~L5)

S1 A 100

Program 2nd line of this advertisement file.

MESSAGE

Store Advertisement File 1,back to S mode.

Note1: Max.2 line per file are available, max.100 letters per line are available. (letters per line depends on font size)

46

SM 110

PROGRAM MODE

3.10.2 Delete Advertisement File
At Advertisement programming mode, enter existing Advertisement Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S6

→

ADVER

MESSAGE

[*]

S6.0

ADVER

0

NO SET

[1]

S6.0

ADVER

1

NO SET

[-]

S6.0

ADVER

DEL ?

Y-C N-T

[C]

S6

→

ADVER

MESSAGE

[MODE][MODE]
[MODE]
[6] or [》] five times

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Advertisement File can not be deleted

47

REMARK
Enter S mode.
Lamp S turns on.
Select

advertisement

file

programming mode.
Enter

advertisement

File

programming mode.
Enter

advertisement

File

1.(Ex.

No.1)
Enter deleting mode.
[C] for Yes, [T] for No.
Delete advertisement File 1,back to
S mode.

SM 110

PROGRAM MODE

3.11 Vender File
Vender file is used for programming names of operators. Maximum 16 characters can be entered per
Vender name. A programmed Vender number can be assigned to a preset key. The Vender Number or
Name (Depend on Spec 21 setting) will be printed on the label, if selected label format with print area
for Vender Number and the programmed Vender name can be printed on receipt when SPEC 21 set
to NAME.

OPERATION
[MODE][MODE]
[MODE]
[7] or [》] six times
[*]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S7

→

VENDER

FILE

S7.0

CLERK

0

NO SET

REMARK
Enter S mode.
Lamp S turns on.
Select

Vender

file

programming mode.
Enter

Vender

File

programming mode.
Select vender key.(Ex. V1)

[1][*]

S7.1

CLERK

1

NAME 0

Program operator name for
Vender 1.

[M][I][K][E]
[PLU]

S7.1

CLERK

MIKE

NAME 4

S7

→

VENDER

FILE

Note1: V1 – V99 can be programmed

48

Enter

operator

name

for

V1.(Ex. “MIKE”)
Store Vender File V1,back to S
mode.

SM 110

PROGRAM MODE

3.12 Program Date And Time
The built-in clock system can automatically work once they are set. Date (Month/Day/Year): 2 digits for
each part; Time (Hour/Minute): 2 digits for each part.
OPERATION
[MODE][MODE]
[MODE]
[8] or [》] seven times
[*]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S8

→

DATE

AND TIME

P8.0

DATE

010100

MMDDYY

REMARK
Enter S mode.
Lamp S turns on.
Select

Date

and

Time

programming mode.
Enter

Date

and

Time

programming mode.
Set Month 08, Day 19 and

[0][8][1][9][0][4][*]

P8.1

TIME

0000

HHMM

Year 04.
(Ex. 2004-08-19)
Set Hour 9,Minute 05.

[9][0][0][*]

S8

→

DATE

AND TIME

Store Date and Time, back to
S mode.

49

SM 110

PROGRAM MODE

3.13 Special Message File
Special Message can be used as a description on the label such as receipt, which can be assigned in each
PLU. Since standard format does not have a print area set for Special Message, Special Message cannot
be printed when using these formats. To print Special Message on the label, it is required to use a Free
Format with a Special Message print area programmed. Maximum 16 special messages can be
programmed with each up to 8 programmable lines. Number of line is depends on the size of the print
area or Character Size entry. The default Special Number print on Receipt can be set at SPEC 112 and
printing position can be set at SPEC 125.
Note: If SPEC 43 set to RECEIPT, maximum 8 lines can be programmable for each Special Message
Number and without select a required Free Format.

3.13.1 Program Special Message File
At Programming Mode, select Special Message programming mode and then enter new Special
Message number (Ex. 1) programming mode. *For edit, enter existing Special Message number.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S9

→

SP

MESSAGE

[*]

S9.0

SP MG

0

NO SET

[1][*]

S9.1

M01.01

[MODE][MODE]
[MODE]
[9] or [》] eight times

[M][A][D][E][SP][I][N
][SP][C][H][I][N][A]

S1 A 100

Enter S mode.
Lamp S turns on.
Select special message file programming
mode.
Enter special message File programming
mode.
Enter

the

special

message

File

No.1.(Ex.No.1)
Enter the special message File as the same

S9.1

M01.14

CHINA

S1 A 87

procedures as Commodity Name Entry.
(Ex. “MADE IN CHINA”)

[SIZE]

S9.1

M01.14

CHINA

S2 A 72

[SIZE]…[SIZE]

S9.1

M02.01

CHINA

M3 A 62

[*]

S9.1

M02.01

S9

→

[PLU]

REMARK

S1 A 56
SP

MESSAGE

50

Press [SIZE] key to change font size of the
special message File.
Change font size to M3.
(S1~S5; M1~M5; L1~L5)
Program 2nd line of this special message
File.
Store special message File 1,back to S
mode.

SM 110

PROGRAM MODE

3.13.2 Delete Special Message File
At Special Message programming mode, enter existing Special Message Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S9

→

SP

MESSAGE

[*]

S9.0

SP MG

0

NO SET

[1]

S9.0

SP MG

1

NO SET

[-]

S9.0

SP MG

DEL ?

Y-C N-T

[C]

S9

→

SP

MESSAGE

[MODE][MODE]
[MODE]
[9] or [》] eight times

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Special Message File can not be deleted.

51

REMARK
Enter S mode.
Lamp S turns on.
Select

special

message

file

programming mode.
Enter

special

message

File

programming mode.
Enter special message File 1.(Ex.
No.1)
Enter deleting mode.
[C] for Yes, [T] for No.
Delete special message File 1,back
to S mode.

SM 110

PROGRAM MODE

3.14 Ingredient File
Ingredients data programmed in this Master Ingredient file can be printed on the Free Format (F1-F99)
with ingredient print area. The size of print area will decide the numbers of lines and characters of
every line. Maximum 15 lines can be programmed for each Master ingredient data and up to 16 Master
Ingredients data can be programmed in this file.
Note: Maximum 39 lines can be programmed for each Master Ingredient data when SPEC 43 set to 0.

3.14.1 Program Ingredient File
At Programming Mode, select Ingredient programming mode and then enter new Ingredient number
(Ex. 1) programming mode. *For edit, enter existing Ingredient number.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S10

→

INGR

FILE

[*]

S10.0

INGR

0

NO SET

[1][*]

S10.1

G01.01

[MODE][MODE]
[MODE]
[10] or [》] nine times

S1 A 100

REMARK
Enter S mode.
Lamp S turns on.
Select

Ingredient

file

programming mode.
Enter

Ingredient

File

programming mode.
Enter

the

Ingredient

File

No.1.(Ex.No.1)
Enter the Ingredient File as the

[S][U][G][A][R]

S10.1

G01.06

SUGAR

S1 A 100

same procedures as Commodity
Name Entry.
(Ex. “SUGAR”)

[SIZE]

S10.1

G01.06

[*]

S10.1

G02.01

[F][L][O][U][R]

S10.1

G02.06

FLOUR

S1 A95

S10

→

INGR

FILE

[PLU]

SUGAR

S2 A 95
S1 A 100

52

Press [SIZE] key to change font
size of the Ingredient File.
Program

2nd

line

of

this

Ingredient File.
Store Ingredient File 1,back to S
mode.

SM 110

PROGRAM MODE

3.14.2 Delete Ingredient File
At Ingredient programming mode, enter existing Ingredient Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S10

→

INGR

FILE

[*]

S10.0

INGR

0

NO SET

[1]

S10.0

INGR

1

NO SET

[-]

S10.0

INGR

DEL ?

Y-C N-T

[C]

S10

→

INGR

FILE

[MODE][MODE]
[MODE]
[10] or [》] nine times

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Ingredients File can not be deleted.

53

REMARK
Enter S mode.
Lamp S turns on.
Select

Ingredient

file

programming mode.
Enter

Ingredient

File

programming mode.
Enter Ingredient File 1.(Ex.
No.1)
Enter deleting mode.
[C] for Yes, [T] for No.
Delete Ingredient File 1,back to
S mode.

SM 110

PROGRAM MODE

3.15 Text File
Maximum 20 Texts are available (Text 1~16 are for Item label and text 17~20 are for Total label). Text
is used for printing the fixed data on label such as “Unit Price”, “packed date”. Text cannot be printed
when using standard format since they do not have any text print area set. You must use a Free Format
with a Text print area programmed. Maximum 2 lines per text can be programmed and number of line
is depends on the size of print area of the selected label format or Character Size entry.
Note: Print Text 5 to 16 on Total label can be set at SPEC 332 setting.

3.15.1 Program Text File
At Programming Mode, select Text programming mode and then enter new Text number (Ex. 1)
programming mode. *For edit, enter existing Text number.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S11

→

TEXT

FILE

[*]

S11.0

TEXT

0

NO SET

[1][*]

S11.1

T01.01

[MODE][MODE]
[MODE]
[11] or [》] ten times

S1 A 100

REMARK
Enter S mode.
Lamp S turns on.
Select Text file programming
mode.
Enter Text File programming
mode.
Enter

the

Text

File

No.1.(Ex.No.1)
Enter the Text File as the same

[P][A][C][K][A][G][E]

S11.1

T01.08

CKAGE

S1 A 93

procedures as Commodity Name
Entry.
(Ex. “PACKAGE”)

[SIZE]

S11.1

T01.08

CKAGE

S2 A 78

[SIZE]…[SIZE]

S11.1

T01.08

CKAGE

S5 A 53

[*]

S11.1

T02.01

[D][A][T][E]

S11.1

T02.05

DATE

S1 A 52

S11

→

TEXT

FILE

[PLU]

S1 A 56

54

Press [SIZE] key to change font
size of the Ingredient File.
Change font size to S5.
(S1~S5; M1~M5; L1~L5)
Program

2nd

line

of

this

Ingredient File.
Store Text File 1,back to S mode.

SM 110

PROGRAM MODE

3.15.2 Delete Text File
At Text programming mode, enter existing Text Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S11

→

TEXT

FILE

[*]

S11.0

TEXT

0

NO SET

[1]

S11.0

TEXT

1

NO SET

[-]

S11.0

TEXT

DEL ?

Y-C N-T

[C]

S11

→

TEXT

FILE

[MODE][MODE]
[MODE]
[11] or [》] ten times

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Text File can not be deleted.

55

REMARK
Enter S mode.
Lamp S turns on.
Select Text file programming
mode.
Enter Text File programming
mode.
Enter Text File 1.(Ex. No.1)
Enter deleting mode.
[C] for Yes, [T] for No.
Delete Text File 1,back to S
mode.

SM 110

PROGRAM MODE

3.16 Free Format File
The Free Format enables you to design your own label format, by setting print angles, print positions,
character size and other programmable items. You can create a new format by copying an existing label
format and use it as a base or make a totally new label format.

3.16.1 General Information
Label format within the following height and width can be created.

• Up to 99 Free Formats can be stored in the memory, apart from the other 16 standard formats.
• Standard format can be used as a basic format for creating a new format.
• Print position of each item is programmed using "mm".
• One Item label or one Total label is available for each Free Format number (F1~F99).
• 4 Print Angles can be set for all item data: 0, 90, 180 and 270 degrees.

56

SM 110

3.16.2 Print Area, Print Position and Print Angles

PROGRAM MODE

All changeable item data should be programmed 8mm above the bottom of the label. The bottom 8
mm of the label should be used for invariable data such as shop name, since this area is printed when
issuing the last label. Please do not program any item closer than 1mm to the edges of the label.
The print position of each item is determined by setting the interval from "0" point (X=0, Y=0) to the
base position of the programmed item. X and Y values need to be entered by "mm".
Print Area
The item data cannot be printed at the bottom 10 mm of labels. Pre-print data such as shop name or
logo data is programmed at the bottom 10mm. Also the item data should not be printed within 1mm
from the left edge or the right edge of the label as the following drawing shows.

57

SM 110
Print Position

PROGRAM MODE

The printing position of each item data is decided by setting the distance from 0 point (X=0, Y=0) to
the base position (X value, Y value).

Print Angle
Print angle of each Print Item can be selected from 4 different angles, 0 degree, 90 degree, 180 degree,
and 270 degree. A whole format base or each Item Data-base may set print angle. According to the
selected print angle, the status of print position differs as the following samples.

58

SM 110

PROGRAM MODE

3.16.3 Programming Parameter Of Print Items
Print Item for Item Label
Up to 82 different item data can be programmed in Item Label Format and is used for printing at
Manual mode and pre-pack mode.
Ty
pe

Display

1. PLU NO

1

PLUno

45. PRICE BEFORE DISCOUNT

1

2. PRICE (-TAX)

1

PRICE

46. UNIT PRICE BEFORE DISCOUNT

1

3. UNIT PRICE

1

UN PR

47 ~ 56.IMAGE 1 ~ IMAGE 10

2

4. WEIGHT

1

WT

57. AVERAGE PRICE

1

5. QUANTITY

1

QTY

58. AVERAGE WEIGHT

1

6. PACKED DATE

1

PDATE

59. BONUS POINT

1

BONUS

7. PACKED TIME

1

PTIME

60. EURO UNIT PRICE

1

EUR U

8. COMMODITY

2

COMM

61. EURO TOTAL PRICE

1

EUR T

9. QUANTITY UNIT

1

QTYSY

62. EURO CALULATION

1

EUR C

10. SELL BY DATE

1

SDATE

63. DUPLICATE TOTAL PRICE

1

11. SELL BY TIME

1

STIME

64. DUPLICATE UNIT PRICE

1

12. BARCODE

3

BARCD

66. BORN COUNTRY

1

BORN

13. SHOP NAME

2

SHOPN

67. FATTEN COUNTRY

1

FAT

14. DISCOUNT VALUE

1

DISCT

68. SLAUGTHER HOUSE

1

SLAUG

15. USED BY DATE

1

UDATE

69. CUTTING HALL

1

CUT H

16. LOGO

2

LOGO

70. REFER NO

1

FEF D

17. MAIN GROUP CODE

1

MG CD

71. ORIGIN

1

ORIGI

18. DEPARTMENT CODE

1

DEPT

72. TEMPERATURE

1

TEMP

19. SCALE NUMBER

1

SCLNO

73. MULTI BARCODE 1

3

M1BAR

20. INGREDIENT

2

INGR

74. MULTI BARCODE 2

3

M2BAR

21. SPECIAL MESSAGE

2

SP MG

75. SERIAL NO

1

22. FRAME 1

4

FRM 1

76. GROSS WEIGHT

1

23. FRAME 2

4

FRM 2

77. REWRAP

1

24. TARE

1

TARE

78. KIND

1

25. CLERK

1

CLERK

79. CATEGORY

1

26 ~ 41. TEXT 1 ~ TEXT 16

2

TXT??

80. BREED

1

42. PRICE (+ TAX)

1

PRTAX

81. CONTACT

1

43. TAX RAGE

1

TAX R

82. GTIN

1

44. PLACE

2

PLACE

Item Data

Item Data

Ty
pe

Display

IMG??

Note: When SPEC 158 set to "ENABLE" the Screen of Item no.2 will change to "DISCOUNT PRICE" & item
Number 3 change to "DISCOUNT UNIT PRICE", and Item Number of 45 & 46 will appears.

59

SM 110
Print Item for Total Label

PROGRAM MODE

Up to 28 different item data can be programmed in Total Label Format and is used for printing
multiple transaction labels for counter sales at Manual mode, Sub-Total and Grand Total at Pre-pack
mode.
Item Data

Type

Display

Item Data

Type

Display

1. PLU NO

1

PLUno

15. PRICE (- TAX)

1

P-TAX

2. PACK DATE

1

PDATE

16. EXCLUDED TAX AMOUNT

1

ATX

3. WEIGHT

1

WT

17. INCLUDED TAX AMOUNT

1

VTX

4. QUANTITY

1

QTY

18. EURO TOTAL PRICE

1

ERUO

5. QUANTITY UNIT

1

QTYSY

19. USED DATE

1

UDATE

6. PRICE (+ TAX)

1

PRTAX

20. BORN COUNTRY

1

BORN

7. PACKED TIME

1

PTIME

21. FATTEN COUNTRY

1

FAT

8. TOTAL TITLE

1

TOTAL

22. SLAUGTHER HOUSE

1

SLAUG

9. BARCODE

3

BARCD

23. CUTTING HALL

1

CUT H

10. CLERK

1

CLERK

24. REFER DATE

1

REF D

11. TEXT 17

2

TXT17

25. ORIGINAL COUNTRY

1

ORIGI

12. TEXT 18

2

TXT18

26. MULTI BARCODE 1

3

M1BAR

13. TEXT 19

2

TXT19

27. MULTI BARCODE 2

3

M2BAR

14. TEXT 20

2

TXT20

28. SERIAL NO

1

Programmable Data Type
Programmable data

Type 1

Type 2

Type 3

Type 4

X position

YES

YES

YES

YES

Y position

YES

YES

YES

YES

Angle

YES

YES

YES

NO

Status

YES

YES

YES

YES

Character Size

YES

NO

NO

NO

Width

NO

YES

NO

NO

Height

NO

YES

YES

NO

Thickness

NO

NO

NO

YES

60

SM 110

PROGRAM MODE

3.16.4 Free Format Entry

At Programming Mode, select Free Format programming mode and then enter new Free Format
number (Ex. 1) programming mode. *For edit, enter existing Free Format number.
Basic Setting: (width, height, angle and label type)
OPERATION
[MODE][MODE]
[MODE]
[1][2]

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

S12

→

FREE

FORMAT

REMARK
Enter S mode.
Lamp S turns on.
Select

S12.0

FREE

0

1-99

Format

setting

programming mode.
Enter

[*]

Free
Free

Format

setting

programming mode.
Select

Free

Format

File

Number.
[1][*]

S12.1

LABEL

0

WT MM

[4][8][*]

S12.2

LABEL

0

HT MM

[3][5][*]

S12.3

LABEL

0

DG ANGLE

Enter the Free Format File
No.1.(Ex.No.1)
Enter

Label

print

width.(Ex.48mm)
Enter

Label

print

height.(Ex.35mm)
[<<] or [>>] key can change the

[<<] or [>>]

S12.3

LABEL

90

DG ANGLE

selection of label angle.
(0,90,180,270 degree)

[*]

S12.4

LABEL

ITEM

LABEL

[<<] or [>>]

S12.4

LABEL

TOTAL

LABEL

Label angle is turned 90 degree.
Select label type.
(Item Label; Total Label)
Enter item setting.

[*]

S12.5

PLUno

←

1

F

ITEM

Refer to Base Type 1 to 4
setting.

61

SM 110
Base Type 1:

PROGRAM MODE

Item data in Data Base Type1 are Numeric data or Fixed data. The print position of item data can be
programmed by setting X / Y value, Print angle and Character size.

Item Label: PLU No., Price, Unit Price, Weight, Quantity, Packed date, Packed Time, Quantity
Symbol, Sell by date, Sell by time, Discount Price, Used by date, MG No., Dept. No., Scale No., Tare
Weight, Clerk No., and Text data.

Total Label: PLU No., Packed date, Total Weight, Total quantity, Quantity symbol, Total Price,
Packed time, Letter of TOTAL, Clerk No., and Text data.
OPERATION

DISPLAY
PT

kg

$/kg

$

REMARK

Continued from the procedure Basic Setting: (width, height, angle and label type)
←

S12.5

PLUno

[*]

S12.5

PLUno

0

X MM

Enter X value.(Ex.1mm)

[1][*]

S12.5

PLUno

0

Y MM

Enter Y value.(Ex.1mm)

[1][*]

S12.5

PLUno

0

DG ANGLE

[>>][*]

S12.5

PLUno

0

STATUS

[7][*]

S12.5

PLUno

S1

CHAR SIZE

1

F

ITEM

Item setting: PLU No.

Select print angle.(Ex.90 degree)
Enter print status.(Ex. All item print)
Select the character size.(Ex. S5)
[<<] or [>>] key can change the

[>>] four times

S12.5

PLUno

S5

CHAR SIZE

selection of the character size.
(S1~S5; M1~M5; L1~L5)

[*]

S12.5

←

PLUno

Note 1: STATUS TYPE: 0: NO Print

1

F

ITEM

Enter next item setting.

3: Weighing Item 4: Non-weighing Item 7: All Item Print

Note 2: Up to 41 different item data can be programmed in Item Label Format and is used for printing at
Manual Mode and Pre-pack Mode.
Note 3: Up to 14 different item data can be programmed in Total Label Format and is used for printing multiple
transaction labels for counter sales at Manual Mode, Sub-Total and Grand Total at Pre-pack Mode.
Note 4: There are two ways to select the Item Data in Free Format programming by using different keys such as:
• Enter the Item data number key.
• Press [X] key or [−] key to search the Item data.

62

SM 110
Base Type 2

PROGRAM MODE

Item data in Base Type 2 are Alpha-numeric data. The print position of item data can be programmed
by setting the max. print area , X / Y value, width of print area from X value, height of print area
from Y value and print angle.

Item Label: Commodity Name, Shop Name, Logo, Ingredient, and Special Message.
OPERATION

DISPLAY
PT

kg

$/kg

REMARK

$

Continued from the procedure Basic Setting: (width, height, angle and label type)
←

S12.5

SHOPN

[*]

S12.5

SHOPN

0

X MM

Enter X value.(Ex.10mm)

[1][0][*]

S12.5

SHOPN

0

Y MM

Enter Y value.(Ex.1mm)

[1][*]

S12.5

SHOPN

0

DG ANGLE

13

F

ITEM

Item setting: Shop name.

Select print angle.(Ex.180 degree)
Enter width value.

[>>][>>][*]

S12.5

SHOPN

0

WT MM

The width of shop name printing area is
20mm.(Ex. 20mm)
Enter height value.

[2][0][*]

S12.5

SHOPN

0

HT MM

The height of shop name printing area is
15mm.(Ex. 15mm)

[1][5][*]

S12.5

SHOPN

0

STATUS

[7]

S12.5

SHOPN

7

STATUS

[*]

S12.5

SHOPN

←
13

F

63

ITEM

Enter print status.(Ex. All item print)
The status of shop name printing area is all
item printing.
Enter next item setting.

SM 110

PROGRAM MODE

Base Type 3
Item data in Data Base 3 is Barcode data. The print position of bar-code data can be programmed by
setting X / Y value, width of Barcode from X value, height of Barcode from Y value and print angle.
OPERATION

DISPLAY
PT

kg

$/kg

$

REMARK

Continued from the procedure Basic Setting: (width, height, angle and label type)
←

S12.5

BARCD

[*]

S12.5

BARCD

0

X MM

Enter X value.(Ex.5mm)

[5][*]

S12.5

BARCD

0

Y MM

Enter Y value.(Ex.20mm)

[2][0][*]

S12.5

BARCD

0

DG ANGLE

12

F

ITEM

Item setting: Barcode.

Select print angle.(Ex.90 degree)
Enter height value.

[>>][*]

S12.5

BARCD

0

HT MM

The height of shop name printing area is
25mm.(Ex. 25mm)

[2][5][*]

S12.5

BARCD

0

STATUS

[7]

S12.5

BARCD

7

STATUS

[*]

S12.5

←
BARCD

12

F

64

ITEM

Enter print status.(Ex. All item print)
The status of BARCODE printing area is
all item printing.
Enter next item setting.

SM 110

PROGRAM MODE

Base Type 4
Item data in Data Base 4 is Frame data. The print position of Frame data may be programmed by
setting X value, Y value, X1 value, Y1 value [the opposite point against the point (X,Y) on a diagonal
line], and line weight.
OPERATION

DISPLAY
PT

kg

$/kg

REMARK

$

Continued from the procedure Basic Setting: (width, height, angle and label type)
←

S12.5

FRM 1

[*]

S12.5

FRM 1

0

X MM

Enter X value.(Ex.10mm)

[1][0][*]

S12.5

FRM 1

0

Y MM

Enter Y value.(Ex.1mm)

22

F

ITEM

Item setting: Frame 1.

Enter X1 value.
[1][*]

S12.5

FRM 1

0

X1 MM

The X1 of frame 1 printing area is
20mm.(Ex. 20mm)
Enter Y1 value.

[2][0][*]

S12.5

FRM1

0

Y1 MM

The Y1 of frame 1 printing area is
15mm.(Ex. 15mm)

[1][5][*]

S12.5

FRM 1

0

STATUS

Enter print status.(Ex. All item print)
Enter line weight.

[7][*]

S12.5

FRM 1

0

T MM

The line weight of frame 1 printing area is
2mm.(Ex. 2mm)

[2][*]

S12.5

FRM 1

←
22

F

65

ITEM

Enter next item setting.

SM 110

PROGRAM MODE

3.16.5 Free Format Copy Function

At Free Format programming mode, Select Copy existing Label Format and then select the existing
label format you want to be copy (Ex. T7) and go to next selection.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

Enter S mode.

[1][2][*]

S12.0

FREE

0

1-99

Enter X value.(Ex.10mm)

[1]

S12.0

FREE

1

1-99

[X]

S12.0

FREE

[7] or
[<<] and [>>]
[*][PLU]

NO

0

COPY

Enter the Free Format File
No.1.(Ex.No.1)
Press [X] key to enter free
format copy function.
Press [7] or [<<] and [>>] to

S12.0

FREE

T7

7

COPY

select the existing label format
you want to be copy.(Ex. T7)

S12

→

FREE

FORMAT

Store the free format file 1, back
to S mode.

Note1: Another way to select the existing label format to copy by press [<<] Key or [>>] Key.

3.16.6 Free Format Delete Function
The Free Format Label cannot be deleted when the label is linked to existing PLU file.
At Free Format programming mode, enter existing Free Format Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S12.0

FREE

0

1-99

[1]

S12.0

FREE

1

1-99

[-]

S12.0

FREE

DEL ?

Y-C N-T

[C]

S12.0

→

FREE

FORMAT

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Free Format File can not be deleted.

66

REMARK
Enter

Free

Format

programming mode.
Enter free format file number 1.
Enter delete mode.
[C] for Yes,[T] for No.
Delete free format file 1, back to
S mode.

SM 110

PROGRAM MODE

3.16.7 Sample of program a format by modifying the existing format

You can create your desired label format by copying an existing format and modifying it to your needs.

67

SM 110

PROGRAM MODE

Following is the example on how to customize standard format T8 to your needs. E.g. Add an
ingredient text and remove the PLU # from the standard Item Label Format
OPERATION

DISPLAY
PT

kg

$/kg

$

S12

→

FREE

FORMAT

REMARK
At Free Format program mode
Enter

[*]

S12.0

FREE

0

1-99

Free

Format

setting

programming mode.
Select Free Format File Number.

[8]

S12.0

FREE

[X]

S12.0

FREE

[8] or
[<<] and [>>]

[*]

8

1-99

NO

COPY

0

Enter the Free Format File
No.1.(Ex.No.8)
Press [X] key to enter free format
copy function.
Press [8] or [<<] and [>>] to

S12.0

FREE

T8

8

COPY

select the existing label format
you want to be copy.(Ex. T8)

S12.1

LABEL

56

WT MM

Change label width (Ex. No
change).
Change label height (Ex. No

[*]

S12.2

LABEL

55

HT MM

[*]

S12.3

LABEL

0

DG ANGLE

[*]

S12.4

LABEL

ITEM

LABEL

[*]

S12.5

PLUno

[*][*][*][*]

S12.5

PLUno

7

STATUS

[C]or[0]

S12.5

PLUno

0

STATUS

[*][*]

S12.5

PLUno

←

1

F

ITEM

[8]

S12.5

COMM

←

8

F

ITEM

F

1

←

ITEM

change).
Change print angle.( Ex. No
change)
Select Item Label.
Enter item setting.
Enter PLU Number print Status
mode.
Change the status to NO PRINT
Save the setting and go to next
selection.
Select

Commodity

Name

program mode.
Enter Y position setting mode

[*][*][3][2]

S12.5

COMM

23

Y MM

and change it from 23 mm to 32
mm and go to next selection.

[*]

S12.5

COMM

0

DG ANGLE

68

Change print angle.( Ex. No
change)

SM 110
OPERATION

PROGRAM MODE
DISPLAY
PT

kg

$/kg

REMARK

$

Enter TTL Height setting mode,
[*][*][1][5]

S12.5

COMM

15

HT MM

change the height from 21 mm to
15 mm and go to next selection.

[*]

S12.5

COMM

7

STATUS

[*]

S12.5

COMM

←

8

[2][0]

S12.5

INGR

←

20

[*]

S12.5

INGR

0

X MM

[2][*]

S12.5

INGR

0

Y MM

[2][3][*]

S12.5

INGR

0

DG ANGLE

[*]

S12.5

INGR

0

WT MM

[5][4][*]

S12.5

INGR

0

HT MM

[1][0][*]

S12.5

INGR

0

STATUS

[7][*]

S12.5

INGR

[PLU]

S12

→

Enter print status. ( Ex. No
change)
Save the Commodity Name print

F

ITEM

F ITEM

setting.
Select Ingredient program mode.
Enter Ingredient programmable
mode.
Enter X Position value (Ex.
2mm) and go to next selection.
Enter Y Position value (Ex.
23mm) and go to next selection.
Change print angle (Ex. No
change).
Enter WIDTH value (Ex. 54mm)
and go to next selection.
Enter HEIGHT value (Ex.
10mm) and go to next selection.
Select print status (Ex. 7 = ALL

←

F ITEM

20

FREE

FORMAT

69

PRINT) and go to next selection.
Save the Free Format number 8.

SM 110

PROGRAM MODE

3.17 Place File
PLACE file is used for programming a short text describing the place of production. The number of
Characters possible to enter depends on the PLACE print area size and the character size used. Place
will be printed in the free room of Commodity Name print area if selected label format without Place
print area. Maximum 99 places (Place number 1 ~ 99) can be programmed, each with 1 line.

3.17.1 Program Place File
At Programming Mode, select Place programming mode and then enter new Place number (Ex. 1).
*For edit, enter existing Place number.
DISPLAY

OPERATION

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

[1][5][*]

S15.0

PLACE

0

NO SET

Enter Place File programming mode.

[1][*]

S15.1

P01.01

S1 A100

Enter place file No.(Ex. No.1)

Enter S mode.

Enter the Place File as the same
[M][A][D][E][SP]……

S15.1

P01.13

DIGI

S1 A 88

procedures as Commodity Name Entry.
(Ex. “MADE IN DIGI”)

[SIZE][SIZE]…
[PLU]

S15.1

P01.13

DIGI

S5 A 48

S15

→

PLACE

FILE

Change font size to S5.
(S1~S5; M1~M5; L1~L5)
Store Place File 1,back to S mode.

3.17.2 Delete Place File
At Place programming mode, enter existing Place Number (Ex. 1) to be deleted.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

S15.0

PLACE

0

NO SET

Enter Place File programming mode.

[1]

S15.0

PLACE

1

NO SET

Enter Place File number 1.

[-]

S15.0

FREE

DEL ?

Y-C N-T

[C]

S15

→

PLACE

FILE

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Place File can not be deleted.

70

Enter delete mode.
[C] for Yes,[T] for No.
Delete Place File 1, back to S mode.

SM 110

PROGRAM MODE

3.18 Machine Setting
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

Enter S mode.

[1][6][*]

S16.0

RATE

0.00

DISC

Program Machine Code.

[5][0][0]

S16.0

RATE

5.00

DISC

S16

→

MACHIN

SETTING

[*]

Note1: 0% to 99.99% are available for Default Discount Rate.

71

Enter default discount rate.(Ex.
5.00%)
Store machine setting, back to S
mode.

SM 110

PROGRAM MODE

3.19 Logo File
Logo is the trademark of the shop, which will be printed in Label or Receipt. Logo will be printed on
the top of receipt and on the left side of shop name on label. (When printing Logo data on Free
Format Label, set the print area of Logo data on the Free Format in advance.)
Logo data can be programmed up to 4 logos. When using 4 logos for label, assign the LOGO KEY to
preset key in advance.

A logo data is formed by a pattern of dots (128 horizontal dots and 64 vertical

dots.) However, since the Label logo data is printed within the limits, which are programmed in label
formats, program the logo data within the limits of print area on the format.
Note: All standard formats have 37 dots x 30 dots for logo print area.

3.19.1 Pre-programming Logo Data
1) Prepare a section paper with 128 horizontal dots and 64 vertical dots.
2) When programming Label Logo, draw the limit of the Logo print area.
3) Draw the desired logo design in the section paper by filling the section with dot. (The dots are
necessary to seize the image of the actual logo before programming.)

Example: DIGI Logo for label (37 x 30 dots)

72

SM 110

PROGRAM MODE

3.19.2 Program Display & Keys Function
Program Display for Logo Set Up
The following display appears when entering Logo Program Mode.

Key Function for LOGO Set Up
[0]

------- Clear a dot.

[1]

------- Fill a dot.

[<<]

------- Move the cursor to left. [I]

[>>]

------- Move the cursor to right. [J]

[《]

------- Move the cursor to up. [K]

[》]

------- Move the cursor to down. [L]

[*]

------- Move up to the first dot in the next line.

[PLU]

------- Store the Data.

73

SM 110

PROGRAM MODE

3.19.3 Programming Order
1) After filling a section, programming status (the position of the cursor) moves to the next dot
automatically.
2) When the programming status reached to the last dot (128 horizontal dots), or [*] key is depress,
the programming status moves to the first left section on the next upper line automatically.

3.19.4 Program Logo File
At Programming Mode, select Logo programming mode and enter new Logo number. (Ex. 1)
*For edit, enter existing Logo number.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

S1

→

PLU

FILE

Enter S mode.

[1][7][*]

S17.0

LOGO

0

NO

Enter Logo File programming mode.

SET

Enter Logo File number.(Ex. 1)

[1][*]

S17.1

LOGO

0

X-POS

Enter X position.(Ex. 7 dots)

[7][*]

S17.2

LOGO

0

Y-POS

Enter Y position.(Ex. 1dots)
Set Fill or Clear dots you want and the save the

[1][*]

S17.3

LOGO

000000

007-01

setting and go to next upper line (Y
02).(Ex.11101110001)

[1][1]……[0][1][*]

S17.3

LOGO

000000

001-02

Press [>>] key to move the cursor to next dot.
If necessary to change the position of the

Press[>>]key 6 times

S17.3

LOGO

000000

007-02

cursor been set, the following procedure is
required.
Change the Horizontal start position (Ex. 5

[-][-]

S17.3

LOGO

7

X-POS

[5][*]

S17.3

LOGO

2

Y-POS

Change the Vertical start position (Ex. NO
CHANGE).

[*]

S17.3

LOGO

000000

005-02

After complete program Logo data, save it.

S17

→

LOGO

FILE

Store the Logo 1 data, back to S mode.

[PLU]

dots).

Note1: If you want to exit without saving, press [◇] key follow by [C] key.

74

SM 110

PROGRAM MODE

3.19.5 Delete Logo File

At Logo programming mode, enter existing Logo Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S17.0

LOGO

0

NO SET

[1]

S17.0

LOGO

1

NO SET

[-]

S17.0

LOGO

DEL ?

Y-C N-T

[C]

S17

→

LOGO

FILE

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Logo File can not be deleted.

75

REMARK
Enter Logo File programming
mode.
Enter Logo File number 1.
Enter delete mode.
[C] for Yes,[T] for No.
Delete Logo File 1, back to S
mode.

SM 110

PROGRAM MODE

3.20 Tax File
This function enables you to program consumption tax rate included or excluded in the price. Up to 10
Tax Numbers (1 - 10) can be programmed. The programmed Tax rates (Tax Number) that are linked
to a Main Group will apply for all PLU's in that Main Group or set the Tax Number in individual PLU
File. Tax Rates can be entered between 00.00 % - 99.99 %. To enable TAX programming mode, SPEC
603 must set to 1 (TAX) in advance.
There are two types of Taxes:
•

ADD ON TAX: Tax is added to the Total Price.

•

VAT TAX: Tax is included in the Total Price.

Note: If you want print PRICE WITH TAX on Item Label, the selected label format must has print area for
Price + Tax and SPEC 659: SELECTION OF ITEM PRICE PRINTING must set to ITEM PRICE
AFTER TAX in advance.

3.20.1 Program Tax File
At Programming Mode, select TAX programming mode and then enter new Tax number (Ex. 1)
programming mode. *For edit, enter existing Tax number.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

REMARK
Enter S mode.
Enter Tax File programming

[1][8][*]

S18.0

TAX

0

NO SET

mode.
Enter Tax File number.(Ex. 1)
Enter

default

tax

rate.(Ex.

[1][*]

S18.1

TAX

0.00

INCLUDE

[3][0][0]

S18.1

TAX

3.00

INCLUDE

Select tax type.

[<<] or [>>]

S18.1

TAX

3.00

EXCLUDE

Tax File 1 is value added tax.

S18

→

TAX

FILE

[PLU]

Note1: 0 % to 99.99 % are available for Default Tax Rate.
Note2: [<<] and [>>] key can change the tax type. (Include / Exclude)

76

3.00%)

Store the Tax File 1 data, back
to S mode.

SM 110

PROGRAM MODE

3.20.2 Delete Tax File
When the Tax Number linked to the existing Main Group File or PLU File, the Tax Number cannot
be deleted. In addition, the Tax Number 1 cannot be deleted.
At Tax programming mode, enter existing Tax Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S18.0

TAX

0

NO SET

[1]

S18.0

TAX

1

NO SET

[-]

S18.0

TAX

DEL ?

Y-C N-T

[C]

S18

→

TAX

FILE

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Tax File can not be deleted.

77

REMARK
Enter Tax File programming
mode.
Enter Tax File number 1.
Enter delete mode.
[C] for Yes,[T] for No.
Delete Tax File 1, back to S
mode.

SM 110

PROGRAM MODE

3.21 Scroll Message File
Maximum 100 characters can be programmed for each scroll message and up to 9-scroll message data
are available in scroll message file.

3.21.1 Program Scroll Message File
At Programming Mode, select Scrolling Message programming mode and then enter new Scroll
Message number (Ex. 1) programming mode. *For edit, enter existing Scroll Message Number.
DISPLAY

OPERATION

PT

kg

$/kg

$

S1

→

PLU

FILE

REMARK
Enter S mode.
Enter Scrolling Message programming

[1][3][*]

S13.0

SC MG

0

NO SET

mode.
Enter Scrolling Message number.(Ex. 1)

[1][*]

S13.1

SC MG

0
Enter Scroll Message.

[W][E][L][C][O][M][E

S13.1

][SP][T][O]……

SC MG

STORE

21

(Ex.

“WELCOME

TO

DIGI

STORE”)

[PLU]

S13

→

SCROLL

MESSAGE

Store the Scroll message 1 data, back to
S mode.

3.21.2 Delete Scroll Message File
When the Scroll message number is linked to Scroll Sequence, it can’t be deleted.
At Scrolling Message program mode, enter existing Scroll Message Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S13.0

SC MG

0

NO SET

[1]

S13.0

SC MG

1

NO SET

[-]

S13.0

SC MG

DEL ?

Y-C N-T

[C]

S13

→

SCROLL

MESSAGE

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Scroll Message File can not be deleted.

78

REMARK
Enter Scrolling Message programming
mode.
Enter Scrolling Message number.(Ex.
1)
Enter delete mode.
[C] for Yes,[T] for No.
Delete Scrolling Message File 1, back
to S mode.

SM 110

PROGRAM MODE

3.22 Scroll Sequence File
Scroll Sequence # 1 to # 3 is available. Each scroll sequence consists of up to three kinds of Messages.
Scroll Sequence means the scroll display order and display appearance of the programmed scroll
message.

3.22.1 Program Scroll Sequence File
At Programming Mode, select Scrolling Sequence programming mode and then enter new Scroll
Sequence number (Ex. 1) programming mode. *For edit, enter existing Scroll Sequence Number.
OPERATION

DISPLAY
PT

kg

$/kg

$

S1

→

PLU

FILE

[1][4][*]

S14.0

SC SQ

0

NO SET

[1][*]

S14.1

SC SQ

MSG NO

000

[1][2][3][*]

S14.2

SC SQ

ATTRIB

123 000

REMARK
Enter S mode.
Enter

Scrolling

Sequence

programming mode.
Enter Scrolling Sequence file
number.(Ex. 1)
Enter existing Scrolling Message
Number.(Ex. 1, 2, 3)
Select Scrolling pattern for each

[1][2][3][*]

S14.2

SC SQ

SPEED

123 000

Scrolling Message.
(Ex. MSG#1=1, MSG#2=2 &
MSG#3=3)
Select Scrolling Rate.
(Ex.

[1][2][0]

S14.2

SC SQ

SPEED

123 120

MSG#1=1:NORMAL,MSG#2
=2:FAST

and

MSG#3=0:SLOW)
[PLU]

S14

→

SCROLL

The scrolling pattern is as following.
0: L–SCROLL: Maximum100 characters
1: BLINKING: Maximum 25 characters
2: STATIS:

Maximum 25 characters

3: R –SCROLL: Maximum100 characters
4: WIPE IN:

Maximum 25 characters

79

SEQUENC

Store the Scroll message 1 data,
back to S mode.

SM 110

PROGRAM MODE

3.22.2 Enable or Disable Scroll Sequence File
This Function is used to enable the programmed Scroll Message data by Scroll Sequence Number
shows on the Display in Registration Mode when scale in idle time. The Scroll Message, Scrolling
Pattern and Speed will follow Scroll Sequence Number setting.
Enable Scroll Sequence File
At Scroll Sequence programming Mode, enter Scroll Sequence Number you want (Ex. 1).
OPERATION

[1]
[PLU]

DISPLAY
PT

kg

$/kg

$

S14.0

SC SQ

0

NO SET

S14.0

SC SQ

1

NO SET

S14

→

SCROLL

SEQUENC

REMARK
Enter

Scrolling

Sequence

programming mode.
Enter Scrolling Sequence file
number.(Ex. 1)
Enable

Scrolling

Sequence

Number 1, back to S mode.

Note1: If you want to change the Scroll Sequence number, enter new sequence number follow by press [PLU] key.

Disable Scrolling Message
At Scroll Sequence programming Mode, enter Scroll Sequence Number you want (Ex. 0).
OPERATION

[0]
[PLU]

DISPLAY
PT

kg

$/kg

$

S14.0

SC SQ

0

NO SET

S14.1

SC SQ

0

NO SET

S14

→

SCROLL

SEQUENC

80

REMARK
Enter

Scrolling

Sequence

programming mode.
Enter Scrolling Sequence file
number.(Ex. 0)
disable

Scrolling

Sequence

Number 1, back to S mode.

SM 110

PROGRAM MODE

3.22.3 Delete Scroll Sequence Number
When the Scroll Sequence Number to be deleted is in Used, it can’t be deleted.
At Scroll Sequence programming mode, enter existing Scroll Sequence Number (Ex. 1) to be deleted.
OPERATION

DISPLAY
PT

kg

$/kg

$

S14.0

SC SQ

0

NO SET

[1]

S14.0

SC SQ

1

NO SET

[-]

S14.0

SC SQ

DEL ?

Y-C N-T

[C]

S14

→

SCROLL

SEQUENC

Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Scroll Sequence File can not be deleted.

81

REMARK
Enter

Scrolling

Sequence

programming mode.
Enter Scrolling Sequence file
number.(Ex. 1)
Enter delete mode.
[C] for Yes,[T] for No.
Delete

Scrolling

Sequence

Number 1, back to S mode.

SM 110

PROGRAM MODE

3.23 ASCII Character Input Method
Insert Key-sheet for ASCII Character Input: (For standard version)

A/a
1

B/b
2

C/c
3

D/d
4

E/e
5

F/f
6

G/g
7

H/h
8

I/i
9

J/j
0

K/k
!

L/l

M/m

N/n
$

O/o
%

P/p
^

Q/q
&

R/r
*

S/s

T/t

(

)

U/u
:

V/v
=

W/w
"

X/x
/

Y/y
-

Z/z
\

?/?
+

ü/ü
?

?/?
<

é/é
.

?/?
>

?/?
,

à/á
€

?/í
ó

@

←

→

Each key includes 3-4 ASCII character.
Example: Key [A/a/1/!] includes ASCII character: A, a and 1.
Operation

ASCII

Display

Indicate

Remarks

Depress the key one time

INPUT ‘A’

A

Lamp P turns on

*note 1

Depress the key two times

INPUT ‘a’

a

Lamp P turns off

*note2

Depress the key three times

INPUT ‘1’

1

Lamp P turns off

*note3

Note1: Lamp P turning on indicates capital letter is use in PLU programming.
Note2: After one letter input, the indicator under the letter is flicker 1.5 seconds.
Note3: When the indicator under the letter is flicker, depress the same key can change the input to the next ASCII
character.

82

SM 110

PROGRAM MODE

3.24 ASCII Code Input Method
ASCII Code Input Method is another kind of input method for ASCII character entry. [CODE] Key
can switch the input method between ASCII Code Input Method and ASCII Character Key In
Method.
Example: Use the ASCII Code Input Method to entry commodity name. (CAKE)
DISPLAY

OPERATION

REMARK

PT

kg

$/kg

$

……

……

……

……

S1.3

C01.01

[CODE]

S1.3

C01.01

A-

S1 A 22

[6][7]

S1.3

C01.02

A-

S1 A 21

[6][5]

S1.3

C01.03

A-

S1 A 20

[7][5]

S1.3

C01.04

A-

S1 A 19

[6][9]

S1.3

C01.05

A-

S1 A 18

……

S1 A 22

……
Enter commodity name.
Press [CODE] to switch to
ASCII Code Input .
ASCII

Code

67

figures

65

figures

75

figures

69

figures

Character ‘C’.
ASCII

Code

Character ‘A’.
ASCII

Code

Character ‘K’.
ASCII

Code

Character ‘E’.
Switch to key in method.

[CODE]

S1.3

C01.01

CAKE

S1 A 18

The inputted characters will be
displayed in the Unit Price
window.

……

……

……

……

……

……

Note1:

Decimal digital from 32 to 255 can be entered. Each Decimal digital figures one ASCII Character.

Note2:

Different Countries can refer to the local ASCII Code List.

83

SM 110

REGISTRATION MODE

4. REGISTRATION MODE
4.1 ON/OFF
1 - ZERO
OPERATION

2 - NET

3 - FIX T

KEYS

PT

4 - FIX P
Kg

$/kg

$

1

2

3

4

kg
Power on.

[ON/OFF]

0000 00000 000000 0000000
1111 11111 111111 1111111
2222 22222 222222 2222222
1333 33333 333333 3333333
4444 44444 444444 4444444
5555 55555 555555 5555555
6666 66666 666666 6666666
7777 77777 777777 7777777
8888 88888 888888 8888888
9999 99999 999999 9999999
**** ***** ****** *******
.

.

.

.

.
,

,

,
,

,

.

. .

.

.

,

, ,

,

,

.
,

.

.

.

.

,

,

,

,

.
,

.

.

.

.

.

.

,

,

,

,

,

,

^^^^ ^^^^^ ^^^^^^ ^^^^^^^
8888 88888 888888 8888888
Stand-by-status.

0.0 0 0

Power off.

0.0 0 0

0.0 0

0.0 0

[ON/OFF]

4.2 Reset and Weighing Check
All weighing operations will be performed based on the procedure shown below. Operator should
check this operation before any transactions.
1 - ZERO
OPERATION

2 - NET
KEYS

3 - FIX T
PT
kg

Stand-by-status.
Reset the zero point.

0.0 0 0
[REZERO]

Kg

4 - FIX P
$/kg

0.0 0

0.0 0

$

1
0.0 0

8888 88888 888888 8888888

Place an item on the platter. (e.g. 1.00kg)
[1] [2] [0]
Remove the item from platter.

84

0.0 0 0

0.0 0

0.0 0

0.0 0

0.0 0 0

1.0 0 0

0.0 0

0.0 0

0.0 1 0

1.0 0 0

1.2 0

1.2 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2

3

4

SM 110

REGISTRATION MODE

4.3 Tare Subtraction
4.3.1 One touch Tare Subtraction
1 - ZERO

2 - NET
KEYS

OPERATION

3 - FIX T
PT
kg

Stand-by-status.
Put tare (e.g 30 g) on platter.
Subtract the tare weight.

[T]

Remove the tare weight
Clear the tare weight.

[T]

Kg

4 - FIX P
$/kg

$

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 3 0

0.0 0

0.0 0

0.0 3 0

0.0 0 0

0.0 0

0.0 0

0.0 3 0 - 0.0 3 0

0.0 0

0.0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

1

2

3

4

1

2

3

4

4.3.2 Digital tare Subtraction
1 - ZERO
OPERATION

2 - NET

3 - FIX T

KEYS

PT
kg

Stand-by-status.

4 - FIX P
Kg

$/kg

$

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Key in the tare weight (e.g 5g).

[5]

0.0 0 0

0.0 0 0

0.0 5

0.0 0

Subtract the tare weight (Assume 15kg).

[T]

0.0 0 5 - 0.0 0 5

0.0 0

0.0 0

Clear the tare weight.

[T]

0.0 0 0

0.0 0

0.0 0

85

0.0 0 0

SM 110

REGISTRATION MODE

4.4 PLU Call Up
There are three ways to cal up programmed PLU:
z

Manual PLU Call Up

z

By press assigns to the preset key that desired PLU.

z

Auto PLU Call Up.

Note: The machine beeps if incorrect operation is performed when during PLU calls up.
z

call Non-Weighed PLU up when something is on the platter.

z

Non-PLU with the entered number exists.

z

PLU Preset Key not set.

4.4.1 Manual PLU Call Up
Manual PLU Call up is by enter the PLU Number by numeric Keys and then follow by pressing [PLU]
key on Keypad.
OPERATION

1 - ZERO
PT
kg

KEYS

Stand-by-status
Enter the PLU No. of the Beef steak.(Ex.No.10)

[0] [1] [0]

Kg

2 - NET
$/kg

3 - FIX T
$

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

1.00

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Clear the PLU and return to Stand-by-status.

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

1

4 - FIX P
2 3 4

4.4.2 PLU Call Up by Preset Key
To enable this function, the PLU must assign on the Preset Key in advance.
OPERATION

1 - ZERO
PT
Kg
kg

KEYS

Stand-by-status
Press the Preset key where desired PLU is

2 - NET
$/kg

3 - FIX T
$
1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

[P1]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2

4 - FIX P
3 4

assigned.
Clear the PLU and return to Stand-by-status.

4.4.3 PLU Call by Numeric Key (Auto PLU Call)
There are two type of Auto PLU Call, by enter the Specification Digits of the PLU Number or by
TIME-OUT is depending on Spec Setting.(Spec39 and Spec40)

86

SM 110

REGISTRATION MODE

OPERATION

1 - ZERO
PT
Kg
kg

KEYS

Stand-by-status
Enter the PLU No. of the Beef steak

[0] [1] [0]

2 - NET
$/kg

0.0 0 0

0.0 0 0

0.0 0

0.0 0 0

0.0 0 0

0.1 0

3 - FIX T
$
1

2

4 - FIX P
3 4

0.0 0
0.0 0
BEEF STEAK

Clear the PLU and return to Stand-by-status.

[C]

0.0 0 0

0.0 0 0

1.20

0.00

0.0 0 0

0.0 0 0

0.0 0

0.0 0

4.5 Fix Operation
4.5.1 Fix Tare by FIX Key
1 - ZERO

2 - NET
KEYS

OPERATION

3 - FIX T
PT
kg

Kg

4 - FIX P
$/kg

$

Stand-by-status.

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Put tare (e.g 30 g) on platter.

0.0 0 0

0.0 3 0

0.0 0

0.0 0

Subtract the tare weight.

[T]

0.0 3 0

0.0 0 0

0.0 0

0.0 0

Fix tare.

[FIX]

0.0 3 0

0.0 0 0

0.0 0

0.0 0

Cancel fix tare by FIX key.

[FIX]

Add tare (e.g 10 g) on platter.

0.0 3 0

0.0 0 0

0.0 0

0.0 0

0.0 3 0

0.0 1 0

0.0 0

0.0 0

Subtract the tare weight.

[T]

0.0 4 0

0.0 0 0

0.0 0

0.0 0

Fix tare.

[FIX]

0.0 4 0

0.0 0 0

0.0 0

0.0 0

Remove the tare weight.

0.0 4 0 - 0.0 4 0

0.0 0

0.0 0

Key in the tare weight (e.g 50g).

[5] [0]

0.0 4 0 - 0.0 4 0

0.5 0

0.0 0

Set new tare and cancel fix tare by T key.

[T]

0.0 5 0 - 0.0 5 0

0.0 0

0.0 0

Fix tare.

[FIX]

0.0 5 0 - 0.0 5 0

0.0 0

0.0 0

Clear the tare weight and fix tare.

[T]

0.0 0 0

0.0 0

0.0 0

0.0 0 0

1

2

3

4

1

2

3

4

4.5.2 Fix PLU by FIX Key
1 - ZERO

2 - NET
KEYS

OPERATION

3 - FIX T
PT
kg

Stand-by-status.

Kg

4 - FIX P
$/kg

$

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Enter the PLU No. of the Beef steak

[1] [0]

0.0 0 0

0.0 0 0

0.1 0

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Fix PLU.

[FIX]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Cancel fix PLU by FIX key.

[FIX]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Enter the PLU No. of the Beef steak

[1] [0]

0.0 0 0

0.0 0 0

0.1 0

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Fix PLU.

[FIX]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

Enter the PLU No. of the Roast Beef.

[2] [0]

0.0 0 0

0.0 0 0

0.2 0

0.0 0

Call up PLU and cancel fix P.

[PLU]

0.0 0 0

0.0 0 0

2.4 0

0.0 0

Fix PLU

[FIX]

0.0 0 0

0.0 0 0

2.4 0

0.0 0

Clear PLU and fix PLU.

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

87

SM 110

REGISTRATION MODE

4.5.3 Fix Unit Price by FIX Key
1 - ZERO

2 - NET
KEYS

OPERATION

3 - FIX T
PT
kg

Stand-by-status.

Kg

4 - FIX P
$/kg

$

1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Enter unit price.

[1] [0] [0]

0.0 0 0

0.0 0 0

1.0 0

0.0 0

Fix unit price.

[FIX]

0.0 0 0

0.0 0 0

1.0 0

0.0 0

Cancel fix unit price.

[FIX]

0.0 0 0

0.0 0 0

1.0 0

0.0 0

Enter unit price.

[2] [0] [0]

0.0 0 0

0.0 0 0

2.0 0

0.0 0

Fix unit price.

[FIX]

0.0 0 0

0.0 0 0

2.0 0

0.0 0

Clear unit price and fix unit price.

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2

3

4

4.6 Operation Mode Change
1 - ZERO
- NET
OPERATION

3 - PREPACK
KEYS

Receipt mode.

PT
kg
0.0 0 0

Depress [MODE] key while depressing

[REZERO]

[REZERO] key.

[REZERO]+[MODE]

Set to label manual mode.
[REZERO]

[REZERO] key.

[REZERO]+[MODE]

Kg
0.0 0 0

0.0 0 0

$/kg
0.0 0

$

1
0.0 0

LABEL

MODE

0.0 0

0.0 0

8888 88888 888888 8888888
RECEIPT

MODE

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

88

2

5 - LABEL

8888 88888 888888 8888888
0.0 0 0

Depress [MODE] key while depressing

Set to receipt mode.

4 - MANUAL

2

3

4

5

SM 110

REGISTRATION MODE

4.7 Item Label Printing in Manual Mode
You can use this operation to print out item labels for a PLU or Non-PLU of Weighing Item or
Non-weighing Item. Before the operation, check the following point.
Š Press [REZERO] and [MODE] to select LABEL mode.
Š Check whether the Label Size fits the programmed one in PLUs when label is used.

4.7.1 Label Printing for PLU Item
For example: Sell 1kg of BEEF STEAK(Ex. PLU #: 10) (Weighing Item).
1 - ZERO

OPERATION

KEYS

2 - NET

3 - FIX T

PT

Stand-by-status.

kg

Kg

4 - FIX P

$/kg

5 - MANUAL

$

1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Enter the PLU No. of the Beef steak.

[1] [0]

0.0 0 0

0.0 0 0

0.1 0

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

0.0 0 0

1.0 0 0

1.2 0

1.2 0

Print out one item label.

[*]

0.0 0 0

1.0 0 0

1.2 0

1.2 0

Remove the product from the platter.

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Place the product on the platter. (e.g. 1kg)

2 3 4

6 - LABEL

5

6

For example: Sell one pack of SMOKED SAUSAGE (Ex. PLU #: 30) and sell five packs of
SLICED BACON (Ex. PLU #: 40). (Non-weighing Item)
1 - ZERO

OPERATION

KEYS

Stand-by-status.

2 - NET

3 - FIX T

PT

kg

Kg

4 - FIX P

$/kg

5 - MANUAL

$

1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

0.3 0

0.0 0

2.5 0

PR-PCS

Enter the PLU No. of the Smoked Sausage.

[3] [0]

Press PLU key.

[PLU]

Press [*] key to print label.

[*]

0.0 0 0

0.0 0 0

0.0 0

1.2 0

Enter the PLU No. of the Sliced Bacon.

[4] [0]

0.0 0 0

0.0 0 0

0.4 0

0.0 0

Press PLU key.

[PLU]

3.2 0

PR-PCS

Multiply.

[X]

QTY 1

3.2 0

3.2 0

5 packs.

[5]

QTY 5

3.2 0

1 6.0 0

Print out one item label.

[*]

0.0 0 0

0.0 0

0.0 0

0.0 0 0

89

2 3 4

6 - LABEL

5

6

SM 110

REGISTRATION MODE

4.7.2 Label Printing for NON-PLU Item
It is possible to print item label for Non-PLU Item at Manual Mode. The Non-PLU Item will be
cleared is a PLU is called up or [C] key is pressed.
Note: For Weighing of Non-PLU Item will be registered to PLU # 999998.
For Non-weight of Non-PLU item, will be registered to PLU # 999999.

For example: Enter the Price for Non-PLU item (Ex. 5.00) by numeric key.
Note: For Non-weight Item, just press [*] key to issue out a label or press [X] key to enter multiply
mode, then enter sale quantity and press [*] key to issue label.
1 - ZERO
3 - FIX T

4 - FIX P

OPERATION

KEYS

Stand-by-status.
Enter the unit price

[5] [0] [0]

Multiply.

[X]

5 packs.

[5]

Print out one item label.

[*]

5 - MANUAL

PT

kg

Kg

$/kg

$

1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

5.0 0

0.0 0

QTY 1

5.00

5.00

QTY 5

5.0 0

25.0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

90

2 - NET

6 - LABEL

2 3 4

5

6

SM 110

REGISTRATION MODE

4.8 Total Label Printing in Manual Mode
This operation is used for printing total label in Manual Mode.

4.8.1 Sales Transaction
This section shows how to operate the transactions with Clerk key. The designated Clerk key
accumulates each transaction data and Total Label will be issued.

For example: Sells 1.5 kg of HERB CHEESE(Ex. PLU #: 3) and 2 packs of SKIM MILK(Ex. PLU
# 302) for customer A.
1 - ZERO
OPERATION

KEYS

Stand-by-status.
Enter the PLU No. of the HERB CHEESE

[3][PLU]

Place the product on the platter. (1.5kg)
Register sales item to Vender1.

PT

kg

Kg

[X][2]

Register sales item to Vender1.

[V1]

Print out one total label.

[*]

$/kg

4 - V2
$

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

5.0 0

0.0 0

0.0 0 0

1.5 0 0

5.0 0

7.5 0

-V1-

TOTAL

1PCS

7.5 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

[3][0][2][PLU]

Enter the sell Qty (Ex. 2 packs)

3 - V1

0.0 0 0

[V1]
[C]

Enter the PLU No. of the SKIM MILK

2 - NET

3.0 0 PR-PCS
QTY 2

3.0 0

6.0 0

-V1-

TOTAL

3PCS

13.5 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

91

5 - V3
1

2

3

6 - V4
4

5

6

SM 110

REGISTRATION MODE

4.8.2 [PRICE DISCOUNT] Function Key in Add Mode
This function key is used to get the desirable discounted total price in Add. Mode by subtracting the
discount value from the original total price when issuing total label or receipt. The formula is shown as
follows
PRICE TO PAY = ORIGINAL TOTAL PRICE - ENTERED DISCOUNT VALUE
Note: Prior to this operation, [PRICE DISCOUNT] Function should be assigned to Preset Key in
advance (Ex. Assign to Preset Key No.2).
OPERATION

KEYS

1 - ZERO
PT kg

Stand-by-status.

2 - NET
Kg

3 - V1
$/kg
$

4 - V2
1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Enter the PLU No. of the Beef steak.

[1] [0]

0.0 0 0

0.0 0 0

0.1 0

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.20

0.0 0

0.0 0 0

1.0 0 0

1.20

1.2 0

1PCS

1.2 0

Place the product on the platter. (e.g. 1kg)
Register sales item to Vender1.

[V1]

-V1-

TOTAL

Press [P2] key.

[P2]

-V1-

DISC

0.00

Enter discount value. (Ex.$0.20)

[2] [0]

-V1-

DISC

0.20

Confirm.

[*]

-V1-

TOTAL

1PCS

1.00

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2

5 - V3
3
4

5

6 - V4
6

4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode
This function key is used to get the desirable discounted total price in Add Mode by setting the
discount % value from the original total price when issuing total label or receipt. The formula is shown
as follows
PRICE TO PAY = ORIGINAL TOTAL PRICE x (100% - DISCOUNT % VALUE)
Note: Prior to this operation, [PRICE % DISCOUNT] Function should be assigned to Preset Key in
advance (Ex. Assign to Preset Key No.3).
1 - ZERO
OPERATION

KEYS

Stand-by-status.

2 - NET

PT

kg
0.0 0 0

Kg

3 - V1
$/kg

0.0 0 0

0.0 0

4 - V2
$
0.0 0

Enter the PLU No. of the Beef steak.

[1] [0]

0.0 0 0

0.0 0 0

0.1 0

0.0 0

Press PLU key.

[PLU]

0.0 0 0

0.0 0 0

1.20

0.0 0

0.0 0 0

1.0 0 0

1.20

1.2 0

-V1-

TOTAL

1PCS

1.2 0

Place the product on the platter. (e.g. 1kg)
Register sales item to Vender1.

[V1]

Press [P3] key.

[P1]

-V1-

DISC

RATE

0.00

Enter discount rate. (Ex.10%)

[1] [0] [0] [0]

-V1-

DISC

RATE

10.00

Confirm.

[*]

-V1-

TOTAL

1PCS

1.08

[C]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

92

5 - V3
1

2

3

6 - V4
4 5 6

SM 110

REGISTRATION MODE

4.9 Data Correction
The data correction during accumulating operation is to correct sales transaction data when customer
canceled the purchases or operators make a mistake before issuing Total Label or Receipt. The
corrected item data is printed with two lines crossed on the Total Receipt.
SM-100 has 2 correcting functions as follows:
1) On-the-spot Correction
Is to void the last item data during accumulating operation.
2) Void by Item Correction
Is to void sales data by tracing transaction number during accumulating operation.

4.9.1 On The Spot Correction
This function is to void the last item data of an accumulating operation, when an operator noticed it
was a mistake or a customer canceled purchase before issuing a Receipt or Total Label. It is effective
for either weighed or non-weighted item in the last transaction.

Transaction Example Vender 1:

(1) 1kg of BEEF STEAK.
(2) One pack of Smoked Sausage.
(3) More 5kg of BEEF STEAK.

But customer canceled 5kg of BEEF STEAK accumulated in the last operation.
1 - ZERO
OPERATION

KEYS

Stand-by-status.
Enter the PLU No. of the Beef Sirloin.

[1] [0] [PLU]

Place the product on the platter. (e.g. 1kg)
Register sales item to Vender1

[V1]

Remove the product from the platter.

2 - NET

PT

kg

Kg

Enter the PLU No. of the Beef Sirloin.

[1] [0] [PLU]

Place the product on the platter. (e.g. 5kg)

$

0.0 0 0

0.0 0

0.0 0

0.0 0 0

1.2 0

0.0 0

0.0 0 0

1.0 0 0

1.2 0

1.2 0

-V1- TOTAL

1PCS

1.2 0

0.0 0 0

-V1- TOTAL
0.0 0 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2.5 0

PR-PCS

2PCS

3.7 0

1.2 0

0.0 0

5.0 0 0

1.2 0

6.0 0

Register sales item to Vender1

[V1]

-V1- TOTAL

3PCS

9.7 0

Delete the last item entry.

[-]

-V1- TOTAL

2PCS

3.7 0

0.0 0

0.0 0

[C]

0.0 0 0

93

0.0 0 0

5 - V3
1

0.0 0 0

0.0 0 0
[V1]

$/kg

4 - V2

0.0 0 0

Enter the PLU No. of the Smoked Sausage. [3] [0] [PLU]
Register sales item to Vender1

3 - V1

2

3

6 - V4
4

5

6

SM 110

REGISTRATION MODE

4.9.2 Void by Item Correction
This function is to void the specified transaction during an accumulating operation. Operator can
designate the number of transaction to be voided even if plural transactions for the same item are
performed.

Transaction example Vender 1:

(1) 1kg of BEEF STEAK.
(2) One pack of Smoked Sausage.
(3) More 5kg of BEEF STEAK.

But customer canceled One pack of Smoked Sausage in the 2nd transaction.
OPERATION

1 - ZERO

2 - NET

KEYS

PT
kg

Stand-by-status.
Enter the PLU No. of the Beef Sirloin.

[1] [0] [PLU]

Place the product on the platter. (e.g. 1kg)
Register sales item to Vender1

[V1]

Remove the product from the platter.

[C]

Enter the PLU No. of the Smoked Sausage.

[3] [0] [PLU]

Register sales item to Vender1

[V1]

Enter the PLU No. of the Beef Sirloin.

[1] [0] [PLU]

Kg

4 - V2

$/kg

$

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

1.2 0

0.0 0

0.0 0 0

1.0 0 0

1.2 0

1.2 0

-V1- TOTAL

1PCS

1.2 0

0.0 0 0

0.0 0

0.0 0

-V1- TOTAL

2PCS

3.7 0

0.0 0 0

2.5 0 PR-PCS

Place the product on the platter. (e.g. 5kg)
Register sales item to Vender1

3 - V1

[V1]
[C]

0.0 0 0

0.0 0 0

1.2 0

0.0 0

0.0 0 0

5.0 0 0

1.2 0

6.0 0

-V1- TOTAL

3PCS

9.7 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

Delete the selected item.

[-]

VD

1

1PCS

1.2 0

[<<] or [>>] to search the item.

[>>]

VD

2

1PCS

2.5 0

Delete the selected item.

[*]

Check Vender1 sale total.

[V1]

0.0 0 0

[C]

0.0 0 0

0.0 0

0.0 0

-V1- TOTAL

2PCS

7.2 0

0.0 0

0.0 0

0.0 0 0

94

0.0 0 0

5 - V3
1

2

3

6 - V4
4 5 6

SM 110

REGISTRATION MODE

4.10 Item Label Printing in Pre-pack Mode
Pre-pack Mode can be switched from Manual mode by pressing [AUTO] key. In this mode, the
following functions are available,
(1) For weighing item, label is automatically issued (without pressing [*] key) after the weight
of the item gets stable. The machine keeps the PLU data until [C] key is pressed.
(2) For non-weighing item, the next label is automatically issued (without pressing [*] key) after
a label is taken away. The machine keeps the PLU data until [C] key is pressed.

4.10.1 Item Label Issue for PLU Item
For example: To weighing (Ex. 1kg) 20 packs of FRIED POTATOES (Weighing Item, PLU #8)
1 - ZERO

2 - NET

OPERATION

KEYS

Stand-by-status.

PT

3 - FIX T

4 - FIX P

kg

$/kg

Kg

5 - PREPACK
$

1

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Press [AUTO] key

[AUTO]

0.0 0 0

0.0 0 0

0.0 0

0.0 0

Enter the PLU No. of the FRIED

[8][PLU]

0.0 0 0

0.0 0 0

2.2 3

0.0 0

0.0 0 0

1.0 0 0

2.2 3

2.2 3

Remove the product from platter and take the

0.0 0 0

0.0 0 0

2.2 3

0.0 0

label off..
Repeat the above 3 and 4 step to weighing the
next pack, until the last packed is weighed.

0.0 0 0

0.0 0 0

0.0 0

0.0 0

2

6 - LABEL
3

4

5

6

3

6 - LABEL
4 5 6

POTATOES (Ex. PLU#8).
Place the product on the platter. (e.g. 1kg) (The
label automatically issued)

For example: issue 20 labels of SMOKED SAUSAGE (Non-Weighing Item, PLU #30).
1 - ZERO

2 - NET
3 - FIX T
KEYS
PT kg
Kg

OPERATION
Stand-by-status.

0.0 0 0

0.0 0 0

4 - FIX P
$/kg
0.0 0

$

5 - MANUAL
1
2

0.0 0

Enter the PLU No. of the Smoked Sausage.

[3] [0] [PLU]

Prepare to issue label for non-weighing item.

[*]

LABEL NUMBER

1

Enter number of labels to be printed, e.g. 20

[2][0]

LABEL NUMBER

20

Print out the first label…

[*]

LABEL

COUNT

20

LABEL

COUNT

19

LABEL

COUNT

1

0.0 0 0

0.0 0

0.0 0

Print out the second label…

2.5 0 PR-PCS

*Note

……
Print out the last label.
Stand-by-status.

0.0 0 0

Note1: To cancel printing, depress C key.

95

SM 110

REGISTRATION MODE

4.10.2 Item Label Issue for NON-PLU Item
It is possible to print item label for Non-PLU Item at Pre-pack Mode. The Non-PLU Item will be
cleared is a PLU is called up or [C] key is pressed.

For example: At Pre-pack Mode, enter the Price for Non-PLU item (Ex. 5.00) by numeric key.
1 - ZERO

2 - NET
KEYS
PT

OPERATION
At Pre-pack Mode
Enter the unit price(Ex.5.00)

[5][0][0]

Place the product on the platter. (e.g. 1kg) (The

3 - FIX T
kg
Kg

4 - FIX P
$/kg

$

5 - PREPACK
1
2
3

0.0 0 0

0.0 0 0

0.0 0

0.0 0

0.0 0 0

0.0 0 0

5.0 0

0.0 0

0.0 0 0

1.0 0 0

5.0 0

5.0 0

0.0 0 0

0.0 0 0

2.2 3

0.0 0

0.0 0 0

0.0 0 0

0.0 0

0.0 0

label automatically issued)
Remove the product from platter and take the
label off..
[C]

Note1: For Non-weight Item, just press [*] key to start issuing out a label and registered to PLU # 999999.
Note2: For Weighing of Non-PLU Item will be registered to PLU # 999998.

96

6 - LABEL
4
5
6

SM 110

READ REPORT MODE

5. READ REPORT MODE
5.1 Report Factor Select
Whether to use the following report print factors depends on the type of report. Please refer to
Operation Flow in Report Mode.

PRINT LIMIT
For setting the report range, Department Number, Main Group Number or PLU Number to start and
finish is to be entered.
LOWER LIMIT:

DEPARTMENT: No.1 - No.99
MAIN GROUP: No.1 - No.999

UPPER LIMIT: DEPARTMENT: No.1 - No.99
MAIN GROUP: No.1 - No.999

5.2 Report Type Selection
There are two ways to select the Report Type by using different keys such as:
•

Preset keys that the desired Report Type is assigned to .

•

By press [X] or [《][》]key to select the Report Type .

Enter Report Mode (“X” Mode) from Stand-by Status.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

0.000

0.000

0.00

0.00

Stand-by Status

[MODE][MODE]

X1.1

READ

MG

DAILY

Enter X mode.

[X]

X2.1

READ

PLU

DAILY

Press [X] key to select the Report Type.

97

SM 110

READ REPORT MODE

98

SM 110

READ REPORT MODE

5.2.1 Main Group Report
Printing report order for MAIN GROUP Daily/Term Read Report:

For example:
• MAIN GROUP LOWER LIMIT: 3
• MAIN GROUP UPPER LIMIT: 996
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

[*]

X1.1

1

ST NUM

Enter starting M.G.(Ex.3)

[3][*]

X1.1

3

ED NUM

Enter ending M.G.(Ex.996)

- REPORT

PRINTING -

[9][9][6][*]

Select M.G. Daily Read Report.

Print M.G. daily Read Report

X1.1

READ

MGROUP

DAILY

Display back to X mode.

[《] or [》] or [X]

X1.4

READ

MG

TERM

Select M.G. Term Read Report.

[*]

X1.4

1

ST NUM

Enter starting M.G.(Ex.3)

[3][*]

X1.4

3

ED NUM

Enter ending M.G.(Ex.996)

- REPORT

PRINTING -

MG

TERM

[9][9][6][*]
X1.4

READ

5.2.2 PLU Report
Printing report order for PLU Daily/Term Read Report:

For example:
• PLU NUMBER LOWER LIMIT: 3
• PLU NUMBER UPPER LIMIT:

999996

99

Print M.G. Term Read Report.
Display back to X mode.

SM 110

OPERATION

READ REPORT MODE

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X2.1

READ

PLU

DAILY

Select PLU Daily Read Report.

[*]

X2.1

1

ST NUM

Enter starting PLU Number.(Ex.3)

[3][*]

X2.1

3

ED NUM

Enter ending PLU Number.(Ex.999996)

- REPORT

PRINTING -

[9][9][9][9][9][6][*]

Print PLU daily Read Report

X2.1

READ

PLU

DAILY

Display back to X mode.

[《] or [》] or [X]

X2.4

READ

PLU

TERM

Select PLU Term Read Report.

[*]

X2.4

1

ST NUM

[3][*]

X2.4

3

ED NUM

- REPORT

PRINTING -

PLU

PERIOD

[9][9][9][9][9][6][*]
X2.4

READ

Enter starting PLU Number.(Ex.3)
Enter ending PLU Number.
(Ex.999996)
Print PLU Term Read Report t
Display back to X mode.

5.2.3 Department Report
Printing report order for DEPARTMENT Daily/Term Read Report:

For example:
• DEPARTMENT LOWER LIMIT:

3

• DEPARTMENT UPPER LIMIT: 96
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X3.1

READ

DEPT

DAILY

Select Dept. Daily Read Report.

[*]

X3.1

1

ST NUM

Enter starting Dept. Number.(Ex.3)

[3][*]

X3.1

3

ED NUM

Enter ending Dept. Number.(Ex.96)

- REPORT

PRINTING -

[9][6][*]

OPERATION

DISPLAY

Print Dept. daily Read Report.

REMARK

PT

kg

$/kg

$

X3.1

READ

DEPT

DAILY

Display back to X mode.

[《] or [》] or [X]

X3.4

READ

DEPT

TERM

Select Dept. Term Read Report.

[*]

X3.4

1

ST NUM

Enter starting Dept. Number.(Ex.3)

[3][*]

X3.4

3

ED NUM

Enter ending Dept. Number.(Ex.96)

- REPORT

PRINTING -

DEPT

TERM

[9][6][*]
X3.4

READ

100

Print Dept. Term Read Report.
Display back to X mode.

SM 110

READ REPORT MODE

5.2.4 Sales Report
Printing report order for SALES Daily/Term Read Report:
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X4.1

READ

SALES

DAILY

Select Sales Daily Read Report.

- REPORT

PRINTING -

Print Sales daily Read Report.

[*]
[《] or [》] or [X]

X4.1

READ

SALES

DAILY

Display back to X mode.

X4.4

READ

SALES

TERM

Select Sales Term Read Report.

- REPORT

PRINTING -

Print Sales Term Read Report.

DEPT

TERM

[*]
X3.4

READ

Display back to X mode.

5.2.5 24Hour Report
On 24 Hour Report, Sales transaction data can be printed on 24-HOUR Daily/Term Read Report
If you want to stop printing, press [FEED] key.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X5.1

READ

24 HOUR

DAILY

Select 24 HOUR Daily Read Report.

- REPORT

PRINTING -

Print 24-HOUR Daily Read Report.

[*]
[《] or [》] or [X]

X5.1

READ

24 HOUR

DAILY

Display back to X mode.

X5.4

READ

24 HOUR

TERM

Select 24-HOUR Term Read Report.

- REPORT

PRINTING -

Print 24-HOUR Term Read Report.

24 HOUR

TERM

[*]
X5.4

READ

Display back to X mode.

5.2.6 ABC Report
ABC Report is used to check the sales situation of PLUs. The share of PLUs against total sales
price are printed on ABC Analysis Report by descending order. The printed shares by descending order
are divided into 3 ranks: A rank, B rank and C rank.
1) Rank A includes PLUs whose accumulated share is less than 75%.
*Even if the accumulated share exceeds 75%, the last PLUs will be included in Rank A.

2) Rank B includes PLUs whose accumulated share is between 75% ~ 95%.
*Even if the accumulated share exceeds 95%, the last PLUs will be included in Rank B.

101

SM 110

READ REPORT MODE

3) Rank C includes PLUs whose accumulated share is between 95% ~ 100%.
*Even if the accumulated share exceeds 95%, the last PLUs will be included in Rank B.

For example: Printing report order for ABC Daily/Term Read Report:
• PLU NUMBER LOWER LIMIT: 1
• PLU NUMBER UPPER LIMIT:
OPERATION

999

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X6.1

READ

ABC

DAILY

Select ABC Daily Read Report.

[*]

X6.1

1

ST NUM

Enter starting PLU NO.(Ex.1)

[1][*]

X6.1

2

ED NUM

Enter ending PLU NO.(Ex.999)

- REPORT

PRINTING -

[9][9][9][*]

Print ABC Daily Read Report.

X6.1

READ

ABC

DAILY

Display back to X mode.

[《] or [》] or [X]

X6.4

READ

ABC

TERM

Select ABC Term Read Report.

[*]

X6.4

1

ST NUM

Enter starting PLU NO.(Ex.1)

[1][*]

X6.4

1

ED NUM

Enter ending PLU NO.(Ex.999)

- REPORT

PRINTING -

ABC

TERM

[9][9][*]
X6.4

READ

Print ABC Term Read Report.
Display back to X mode.

5.2.7 Clerk Report
Clerk report is used to print out the total data such as total prices, total quantity and so on by every
Clerk.

For example: Printing report order for CLERK Daily Read Report:
• CLERK NUMBER LOWER LIMIT: 1
• CLERK NUMBER UPPER LIMIT:
OPERATION

4

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

Lamp X turns on.

[《] or [》] or [X]

X7.1

READ

CLERK

DAILY

Select Clerk Daily Read Report.

[*]

X7.1

1

ST NUM

Enter starting CLERK NO.(Ex.1)

[1][*]

X7.1

1

ED NUM

Enter ending CLERK NO.(Ex.4)

- REPORT

PRINTING -

Print Vender Daily Read Report t

CLERK

DAILY

[4][*]
X7.1

READ

102

Display back to X mode.

SM 110

READ REPORT MODE

5.2.8 Pre-pack Report
On Pre-pack Report, Total data of Prepack labels (Such as total price, total quantity, etc) can be printed
on PREPACK DEPARTMENT REPORT or PREPACK MAIN GROUP REPORT.

For example: Printing report order for PREPACK DEPARTMENT/ MAIN GROUP REPORT:
• DEPARTMENT LOWER LIMIT:

1

• DEPARTMENT UPPER LIMIT: 99
• MAIN GROUP LOWER LIMIT: 1
• MAIN GROUP UPPER LIMIT:

OPERATION

999

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

[《] or [》] or [X]

X8.1

READ

[*]

X8.1

DEPT

1

ST NUM

Enter starting Dept. Number.(Ex.1)

[1][*]

X8.1

DEPT

1

ED NUM

Enter ending Dept. Number.(Ex.99)

- REPORT

PRINTING -

[9][9][*]

PPK
DEPT

PPK

DAILY

X8.1

READ

[《] or [》] or [X]

X8.2

READ

PPK MG

DAILY

[*]

X8.2

DEPT

1

ST NUM

[1][*]

X8.2

DEPT

1

ED NUM

- REPORT

PRINTING -

PPK MG

DAILY

[9][9][9][*]
X8.2

READ

DEPT

103

DAILY

Lamp X turns on.
Select Pre-pack Department Daily
Read Report.

Print Pre-pack Department Daily
Read Report.
Display back to X mode.
Select Pre-pack Main Group Daily
Read Report.
Enter starting Dept. Number.(Ex.1)
Enter

ending

Dept.

Number.(Ex.999)
Print Pre-pack Main Group Daily
Read Report
Display back to X mode.

SM 110

READ REPORT MODE

5.2.9 Tax Report
Tax report is used to print out the Tax total data such as Tax Type, Tax rate, Amount Including Tax,
Amount Excluding Tax, Tax Amount and so on by every Tax Number.
OPERATION

DISPLAY

REMARK

PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

[《] or [》] or [X]

X9.4

READ

TAX

[*]

X9.4

1

ST NUM

Enter starting Tax Number.(Ex.1)

[1][*]

X9.4

1

ED NUM

Enter ending Tax Number.(Ex.3)

- REPORT

PRINTING -

READ

TAX

[3][*]
X9.4

Lamp X turns on.
Select Tax Daily Read Report.

Print Tax daily Read Report.
Display back to X mode.

5.2.10 Store Summarized Report
OPERATION

DISPLAY
PT

kg

$/kg

$

Enter X mode

X1.1

READ

MG

DAILY

[《] or [》] or [X]

X4.3

READ

STORE

SUMMARY

- REPORT

PRINTING -

STORE

SUMMARY

[*]
X4.3

READ

104

REMARK
Lamp X turns on.
Select Store Summarized Daily
Read Report.
Print Store Summarized Daily
Read Report.
Display back to X mode.

SM 110

RESET REPORT MODE

6. RESET REPORT MODE
Reset Sales Daily / Monthly/Term Reset Report
OPERATION

DISPLAY
PT

kg

$/kg

$

Z1.0

RESET

SALES

DAILY

[*]

RESET

REPORT

?

Y-C N-T

[C]

Z1.0

RESET

SALES

DAILY

[《] or [》] or [X]

Z2.0

RESET

SALES

MONTHLY

[*]

RESET

REPORT

?

Y-C N-T

[C]

Z2.0

RESET

SALES

MONTHLY

[《] or [》] or [X]

Z3.0

RESET

SALES

TERM

[*]

RESET

REPORT

?

Y-C N-T

[C]

Z3.0

RESET

SALES

TERM

Enter Z mode

105

REMARK
Lamp Z turns on.
Enter Reset mode.
[C] for Yes,[T] for No.
Display back to Z mode.
Select

Sales

Monthly

Reset

Report.
Enter Reset mode.
[C] for Yes,[T] for No.
Display back to Z mode.
Select Sales Term Reset Report.
Enter Reset mode.
[C] for Yes,[T] for No.
Display back to Z mode.

Specification List

TITLE
REVISION NO.
ISSUED DATE
Rev.
No.
0

SM-110 V1.20

:
:
:

20 December, 2005

SM-110 SPECIFICATION LIST
0
17 August, 2004
Modification Details

First Release

1

Software
Version
1.00

Specification List

SPEC
NO.

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100

CUSTOMER SPECIFICATION [REZERO] + [1][4][1]
00

01

02

Item Barcode
0
F1F2 CCCCC XCD XXXX CD
1
F2 CCCCCC XCD XXXX CD
2
F1F2 CCCCC 0 XXXX CD
3
F1F2 CCCCCC XXXX CD
4
F1F2 CCCCC XXXXX CD
5
F2 CCCCCC XXXXX CD
6
F2 CCCCC XXXXXX CD
7
F1F2 CCCCCCCCCC CD #1
8
F1F2 CCCC XXXXXX CD
9
F1F2 CCCCC CD #2
10 F2 CC XXXX CD #3
11 No Barcode
12 F1X2 CCCCC XCD XXXX CD

9
13
14
15
16
17
18
19
20

F1X2 CCCCCC XXXX CD
F1F2 CCCC XCD XXXXX CD
F2 CCCCC XCD XXXXX CD
F1F2 CCC XXXXXXX CD
F1F2 CC XXXXXXXX CD
CCC WWWW PPPPP CD
No Barcode
F1F2 CCCCC PCD XXXX CD

Right Side Data of Item Barcode
0
Quantity
1
Price
2
Weight
3
User Programmable #

4
5
6
7

Original Price
Weight / Quantity
Unit Price
Unit Price after discount

Right Side Price Data of Item Barcode
0
Price before Tax

1

Price after Tax

All are 13 digits non-PLU
barcode unless
otherwise stated.
#1 13 digits PLU
barcode
#2 8 digits PLU barcode
#3 8 digits non-PLU
barcode

9
# Related to SPEC153.

9
Effective when SPEC1 =
1

03

Flag Data F1 and F2 for 13 Digits Non-PLU Barcode
Enter value from range 0 to 99

9

04

Flag Data F1 and F2 for 13 Digits PLU Barcode
Enter value from range 0 to 99

9

05

Flag Data F2 for 8 Digit Non-PLU Barcode
Enter value from range 0 to 9

9

06

Flag Data F1 and F2 for 8 Digit PLU Barcode
Enter value from range 0 to 99

9

07

Total Barcode
0
F1F2 CCCCC XCD XXXX CD
1
F2 CCCCCC XCD XXXX CD
2
F1F2 CCCCC 0 XXXX CD
3
F1F2 CCCCCC XXXX CD
4
F1F2 CCCCC XXXXX CD
5
F2 CCCCCC XXXXX CD
6
F2 CCCCC XXXXXX CD
7
F1F2 CCCCCCCCCC CD #1
8
F1F2 CCCC XXXXXX CD
9
F1F2 CCCC CD #2
10 F2 CC XXXX CD #3
11 No Barcode

08

Left Side Data of Total Label
0
Scale No.
1
Last Accumulated Item Code
2
Receipt No.

9
12
13
14
15
16
17
18
19
20

F1X2 CCCCC XCD XXXX CD
F1X2 CCCCCC XXXX CD
F1F2 CCCC XCD XXXXX CD
F2 CCCCC XCD XXXXX CD
F1F2 CCC XXXXXXX CD
F1F2 CC XXXXXXXX CD
CCC WWWW PPPPP CD
No Barcode
F1F2 CCCC PCD XXXX CD

3
4

Clerk No.
Fixed No.

All are 13 digits non-PLU
barcode unless
otherwise stated.
#1 13 digits PLU
barcode
#2 8 digits PLU barcode
#3 8 digits non-PLU
barcode

9

09

Fixed Data for Left Side Data of Total Barcode
Enter value from range 0 to 9 999 999 999

9

10

Flag Data F0, F1 and F2 for Total Barcode
Enter value from range 0 to 999

9

2

Specification List

SPEC
NO.
11

12

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Right Side Data of Total Barcode
0
Quantity
1
Price
Total Barcode Print on Receipt
0
No

SM-100
9

2

Weight

1

Yes

9

13

Print Readable Character of F1 for Item and Total Barcode (for EAN only)
0
No Print
1
Print

8

14

Printing Position for Advertisement Message
0
First Line
2
1
Below
3

9
Above
Not Used

15

Turnover Printing for Advertisement Message
0
No
1
Yes

16

Exit from “Change” Mode within Specified Interval
0
No
3
10 sec
1
3 sec
4
15 sec
2
6 sec

9

17

Order of the Month, Day and Year for Print
0
MM/DD/YY
2
1
DD/MM/YY
3

9

18

19

20

YY/MM/DD
Not Used
9

1 or 2 Line(s) Commodity Name on Receipt
0
2 Lines
2
1
1 Line

No Print

Label Printing by Clerk Key
0
No Print
1
Print with Accumulation

2

Print without Accumulated

1

Print

Total Label Printing
0
No Print

9

9

21

Printing Operator Name on Receipt and Label
0
Code
1
Name

9

22

Receipt Paper Width
0
60 mm
1
40 mm

8
2

50 mm

23

Manual Price Entry for Printing or Accumulating
0
Allow
1
Inhibit

24

Default Label Format for Item Printing
0
T1
(A)
1
T2
(B)
2
T3
(C)
3
T4
(U2)
4
T5
(U3)
5
T6
(U4)
6
T7
(U5)
7
T8
(U6)
8
T9
(U7)
9
T10 (U8)
10 T11 (T5)
11 T12 (T6)

9

9
12
13
14
15
16
17
18
19
20
21
22
23

S
A
B
C
F1
F2
F3
F4
F5
F6
F7
F8

3

(T7)
(T8)
(T9)
(T10)
(F1)
(F2)
(F3)
(F4)
(F5)
(F6)
(F7)
(F8)

Formats in ( ) are for U1
and CA only.
F1 to F8 are Free
Format.

Specification List

SPEC
NO.
25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
9

Default Label Format for Total Printing
0
T1
(A)
1
T2
(B)
2
T3
(C)
3
T4
(U2)
4
T5
(U3)
5
T6
(U4)
6
T7
(U5)
7
T8
(U6)
8
T9
(U7)
9
T10 (U8)
10 T11 (T5)
11 T12 (T6)

12
13
14
15
16
17
18
19
20
21
22
23

S
A
B
C
F1
F2
F3
F4
F5
F6
F7
F8

Shop Name Printing on Label
0
No Print

1

Print

Forced Tare Function
0
Disable

1

Enable

Peel Sensor Function in Prepack Mode
0
Disable

1

Enable

(T7)
(T8)
(T9)
(T10)
(F1)
(F2)
(F3)
(F4)
(F5)
(F6)
(F7)
(F8)

Formats in ( ) are for U1
and CA only.
F1 to F8 are Free
Format.

9

9

9

9

Continuous Print for Label in Prepack Mode
0
Inhibit
1

Allow

Selection of CDV
0
Inhibit

1

Allow

CDV Type
0
CDV

1

Tear-off

CDV Modulus
0
Modulus 10

1

Modulus 11

On Spot Correction
0
Allow

1

Inhibit

Search Correction
0
Allow

1

Inhibit

Move Back Correction
0
Allow

1

Inhibit

Past Sales Data Correction
0
Allow

1

Inhibit

Label Print Density
0
Low
1
Mid

2
3

High-mid
High

Receipt Print Density
0
Low
1
Mid

2
3

High-mid
High

2

Time-out

Calling of PLU
0
Manual
1
Auto

SM-100

8
For SF only.

8
For SF only.

8
For SF only.
Effective when SPEC30
and 31 = 1.

9

8

9

9

9

9

PLU Digits for Auto PLU Calling/Time-out Calling
0
3 Digits / 0.5 sec
2
5 Digits / 1.5 sec
1
4 Digits / 1.0 sec
3
6 Digits / 2.0 sec

4

Related to SPEC40.

9
Effective when SPEC39
= 1.

Specification List

SPEC
NO.
41

42

43

44

45

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100

Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa
0
Allow
1
Inhibit

9

Unit Price Override
0
Allow

9
1

Effective when SPEC643
= 1.

Inhibit

Main Usage for Commodity Name, Shop Name and Special Message
0
Receipt
1
Label

9

Tare Override
0
Allow

9
1

Inhibit

Item Printing
0
Allow

1

Inhibit

Always set to 0 for SM200.

9

46

Default Data of Printing Shop Name Number for Label
Enter value from range 0 to 32

9

47

Default Data of Printing Shop Name Number for Receipt
Enter value from range 0 to 32

9

48

Setting of Scale Number
Enter value from range 0 to 999 999

9

49

Type of Client / Server Interface
0
No Interface
1
Ethernet (Coaxial Cable)
2
Ethernet (Twisted Pairs)

3
4

Not Used
4-Lines (RS-485)

Setting of Client / Server
0
Client
1
Server / Workstation

2

Backup Server

Baud Rate of SIO (RS-232C Port)
0
1 200 bps
1
2 400 bps
2
4 800 bps
3
9 600 bps

4
5
6

19 200 bps
38 400 bps
76 800 bps

1

8 Bits

2

Even

1

2 Bits

50

51

52

53

54

55

56

Data Length of SIO (RS-232C Port)
0
7 Bits

Parity Bit of SIO (RS-232C Port)
0
None
1
Odd
Stop Bit of SIO (RS-232C Port)
0
1 Bit

9
Related SPECs for
Ethernet I/F are
SPEC50, 135, 214.

9
Related SPECs for S/C
setting are SPEC61, 150,
163, 165, 187, 194, 208,
229, 252, 253, 254, 255,
265, 276.

9
Apply to both RS-232C
and RS-485 ports setting
for SM-300.
Related SPECs are
SPEC48, 52, 53, 54, 60,
134.

9
Apply to both RS-232C
and RS-485 ports setting
for SM-300.

9
Apply to both RS-232C
and RS-485 ports setting
for SM-300.

9
Apply to both RS-232C
and RS-485 ports setting
for SM-300.

Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port)
0
1 200 bos
3
9 600 bps
1
2 400 bps
4
19 200 bps
2
4 800 bps
5
38 400 bps

8

Data Length of Multi-drop SIO (RS-485 / 4-Lines Port)
0
7 Bits
1
8 Bits

8

5

Related SPECS are
SPEC48, 56, 57, 58, 59,
134.

Specification List

SPEC
NO.

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100

57

Parity Bit of Multi-drop SIO (RS-485 / 4-Lines Port)
0
None
2
Even
1
Odd

8

58

Stop Bit of Multi-drop SIO (RS-485 / 4-Lines Port)
0
1 Bit
1
2 Bits

8

59

Multi-drop SIO (RS-485 / 4-Lines Port) Select Job
0
No Operation
2
Pick ‘N’ Pay #2
1
FIS 3000 #1

8

SIO (RS-232C Port) Select Job
0
No Operation
1
FIS 30000 #1
2
FL-1

8
3
4
5

Point ‘N’ Shop
Barcode Scanning
Video Control #2

Floating Clerk
0
Inhibit

1

Allow

Receipt Free Format
0
Disable

1

Enable

60

61

62

63

64

8
Exclude AA.

8
Yes
9

2

Allow Multi Password

65

Report Printing in Daily and Term Transaction Clear
0
Inhibit
1
Allow

66

Pack Quantity Function Key Enable
0
Allow

1

Inhibit

Advertisement Function Key Enable
0
Allow

1

Inhibit

67

Apply for both RS-232C
and RS-485 ports setting
for SM-300.
#1 Refer to SPEC59’s
comments #1.
#2 For SM-300 only

8

SM-90 and DI-10 RS-232C Communication
0
No
1
Enable Password Mode
0
Allow
1
Inhibit

#1 Either SPEC59 or 60
can be selected at any
one time.
#2 For SF only.

9

9

68

Fixed Total Price Discount Function Key Enable
0
Allow
1
Inhibit

9

69

Total Price Percentage Discount Function Key Enable
0
Allow
1
Inhibit

9

70

Fixed Unit Price Function Key Enable
0
Allow

9
1

Inhibit

71

Fixed Unit Price Percentage Function Key Enable
0
Allow
1
Inhibit

9

72

Pack Date Function Key Enable
0
Allow

9
1

Inhibit

Minus Pack Date Function Key Enable
0
Allow

1

Inhibit

Sell by Date Function Key Enable
0
Allow

1

Inhibit

Unit Symbol Function Key Enable
0
Allow

1

Inhibit

73

74

75

9

9

6

Specification List

SPEC
NO.
76

77

78

79

80

81

82

83

84

85

SM-110 V1.20

SPECIFICATION DESCRIPTION
Quantity Set Function Key Enable
0
Allow

1

Inhibit

Price Change Function Key Enable
0
Allow

1

Inhibit

Refund Item Function Key Enable
0
Allow

1

Inhibit

Shop Name Function Key Enable
0
Allow

1

Inhibit

Logo Function Key Enable
0
Allow

1

Inhibit

Print Select Function Key Enable
0
Allow

1

Inhibit

Print of Place of Production on Label
0
Inhibit

1

Allow

Selection of Markdown
0
No Markdown
1
Unit Price Markdown

2
3

Total Price Markdown
Unit and Total Price Markdown

Sub-total Function Key Enable
0
Allow

1

Inhibit

Grand Total Function Key Enable
0
Allow

1

Inhibit

9

9

9

9

8

Label Sensor Gap Value
Enter value range from 0 to 255

87

Label Type
0
Gap

1

No Gap

Sell by Date Title Print out
0
Inhibit

1

Allow

ASCII Code Entry in S Mode
0
Inhibit

1

Allow

Sub-total Markdown
0
No Markdown

1

Markdown

2

High

2

High

2

Not Used

3
4

3 sec Delay
User Select

1

After Price

89

90

91

92

93

94

Printer Speed for Receipt
0
Slow
1
Normal
Printer Speed for Label
0
Slow
1
Normal
Printer Strode
0
Single
1
Double
Print Second Receipt
0
No Print
1
Continuous Print
2
1 sec Delay
Position of Currency Symbol (on Label)
0
Before Price

SM-100

9

86

88

20 December, 2005

9

8
For AA only.

8
For AA only.

9

9

9

8

9

9

7

Specification List

SPEC
NO.
95

96

97

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100
8

Receipt Printing with Dual Copy
0
Inhibit

1

Allow

Advertisement Message on All Label
0
Inhibit

1

Allow

9

Manual Print in Prepack Mode for Weigh Item
0
Inhibit
1

9
Allow

98

Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode
0
Allow
1
Inhibit

9

99

Unit Print Out for Non-weigh Item in Manual Mode
0
Inhibit
1
Allow

8

100

Discount in PLU Programming
0
Allow

8
1

Inhibit

Zero Suppress for Date and Time
0
Disable

1

Enable

1

Original Unit Price and Price

101

102

103

104

Discount Presentation in Receipt
0
Discounted Unit Price and
Original Price

9

8

Unit Price Assignment Function Key for PLU
0
Enable
1
Discount Price Rounding Method
0
Rounding
1
Cut Down

Disable
9

2

Cut Up

105

Fixed Total Price Markdown Function Key Enable
0
Allow
1
Inhibit

9

106

Total Price Percentage Markdown Function Key Enable
0
Allow
1
Inhibit

9

107

Fixed Unit Price Markdown Function Key Enable
0
Allow
1
Inhibit

9

108

Fixed Unit Price Percentage Markdown Function Key Enable
0
Allow
1
Inhibit

9

109

Source of Sell by Date
0
Real Time Clock

9
1

Packed Date

Year Type
0
Standard

1

Japanese / Taiwan

2

Yen

110

111

Price Symbol on Receipt
0
No Print
1
Kanji Yen

8
For AA and TW only.

8
For AA only.

112

Default Data of Printing Special Message Number for Receipt
Enter value range from 0 to 16

9

113

Label Logo Printing Status
0
No Print
1
Logo 1
2
Logo 2

9
3
4

Logo 3
Logo 4

8

Specification List

SPEC
NO.
114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Receipt Logo Printing Status
0
No Print
1
Logo 1
2
Logo 2
3
Logo 1 and 2

4
5
6

SM-100

Logo 3
Logo 4
Logo 1, 2, 3 and 4

Type of Entry for Used by Date and Sell by Date
0
By Day
1
By Hour

8

Barcode Printing in First Label for Dual Label Printout
0
Print
1
No Print

8

Zero Minutes Printing
0
No Print

8
1

Print

Both Price before and after Discount
0
Price before and after Discount

1

Price before Discount only

2

No Print

PLU Number Print
0
No Zero Suppress

1

Zero Suppress

Thick Japanese Character Printout
0
Thick Character

1

Thin Character

Prepare Mode after Power On
0
Manual Mode

1

Prepack Mode

Unit Symbol Printout in Receipt
0
Depend on PLU Programming
1
Japanese PCS

For NICHII only.

For NICHII only.

9
For AA only.

9

8
For AA only.

8
Always set to 0 for SM200.

8
Disable

PLU Unit Price after Discount
0
Unit Price after Discount

1

Unit Price Discount Amount

Position of Special Message on Receipt
0
Bottom

1

Top

9

9

Function Keys Protection for Self-service
0
No Protection
2
1
Full Protection

1

8
Partial Protection

Enable
8

Setting of Host Number (For SM-15 Multi-drop)
Enter value between 0 to 99
Type of Host to be Communicated
0
Standalone
1
TMR ECR

For NICHII only.

8

Printing Thank You Message on Receipt
0
Enable
1

Printing of Checksum for Item Barcode
0
Disable

For NICHII only.

For IR only.

8
2

POS ECR

For IR only.
Use with SPEC128.

130

Selection of Print Item on Prepack Total Label
0
Based on Status on Item Label
1
Based on Status on Manual Total
Label

9

131

Print PLU Setting Quantity in Manual Mode
0
No
1

9
Yes

Receipt Total Report
0
No

Yes

132

1

9

Effective when SPEC98
= 0.

8
For DM only.

Specification List

SPEC
NO.

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100

133

Change All PLU Default Format when Default SPEC Change
0
Yes
1
No

8

134

Host Communication
0
No Operation
Host Communication
0
RS-232C

8
1

Enable

1

RS-485
9

135

Port Number
Enter value from range 1 to 254

136

One or Two Touch for Self-service Operation
0
One Touch
1

Two Touches

Centering of Ingredient Data
0
Yes

No

137

9

9
1

138

Permanent Price or Discount Price Change via Function Key
0
No Update to PLU
1
Update to PLU

9

139

Number of Digits for Teraoka Code
0
2 Digits

8
1

3 Digits

AA Message Size
0
24 x 24

1

16 x 16

Year Format
0
YY

1

YYYY

140

141

142

143

144

145

146

147

148

149

150

8
For AA only.

9

9

Selection of Day Display for Sell by Date
0
Disable
1

Enable

Peel Sensor Trigger Voltage
0
High

1

Low

Display Prepack Quantity Balance
0
Enable

1

Disable

Print Select Function Across the Board
0
Disable

1

Enable

Label Format 1, 2 Function Key Enable
0
Inhibit

1

Allow

Exclude AA.

Prepack Non-add Function Key Enable
0
Inhibit

1

Allow

Exclude AA.

FIS3000 Code
0
SM-80/90 FIS3D

1

SM-25 FIS3D

Main Group Function Key Enable
0
Inhibit

1

Allow

Preset Key Assignment for Client
0
Local Assign

1

Central Assign

8

8

8

151

Change Sell by Date or Used by Date when Packed Date Changed
0
No
1
Yes

152

Sell by Date or Sell by Time for Individual PLU
0
Disable
1
Enable

153

User Programmable Right Side Data for Item Barcode
0
With Identification Digit
1
Without Identification Digit

10

Exclude AA.

Specification List

SPEC
NO.
154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100
8

Keysheet Letter Size
0
Small Letter

1

Capital Letter

Test Print on Receipt
0
No Print

1

Print

Image Copy from Free Format
0
Disable

1

Enable

Training Mode
0
Disable

1

Enable

FSD Price and Image
0
Disable

1

Enable

½ and ¼ Key Function
0
Disable

1

Enable

Twisted Pair Cable for Ethernet
0
Shield

1

Unshielded

Discount Label Format
0
Enable

1

Disable

Item Code Function Key Enable
0
Enable

1

Disable

Transaction Data Store in Client Memory
0
Disable
1

Enable

Maximum Label Length
0
120 mm

240 mm

For FL & AS only.

8
For SD only.

9

8
Exclude DEC.

8
For U1 only.

8

8
Not in used.

8
For SD only.

8
1

Update Report for Client / Server System
0
Yes
1

No

Average Price and Weight Label Function
0
Disable
1

Enable

Label Date Title Print
0
No Print

1

Print

GB Code
0
GB Code

1

Shift GB Code

Print PLU Setting Unit in Manual Mode
0
No

1

Yes

9
Exclude AA.

8
For CN and MS only.

170

User Specification (REZERO + 141) Accessible from Z Mode Only
0
No
1
Yes

8

171

Euro Mode
0
Disable

9
1

Enable

Dual Declarations
0
No

1

Yes

Mask 7-segment Display in X, S and Z Mode
0
No
1

Yes

172

173

174

8
For U1 only.

8

Fixed Clerk Assign to Preset Key 8, 16, 24 and 32
0
Clerk Keys
1
Function Keys

11

For double display types
only.

8
For bench type only.

Specification List

SPEC
NO.
175

176

177

178

179

180

181

182

183

184

SM-110 V1.20

SPECIFICATION DESCRIPTION

1

Enable

Discount Time on Daily Basis
0
No

1

Yes

Weight Check Function
0
No

1

Yes

Unit Price Override per PLU
0
No

1

Yes

Black Bar Sensing Label
0
Normal

1

Black Bar Sensing

Scroll Message Group
0
Disable

1

Enable

Continuos Label
0
Disable

1

Enable

Character Size for Barcode Data
0
Large

1

Small

PLU Clear after 10 seconds Time-out
0
No

1

Yes

Duplicate Unit and Total Price on Label
0
No Print

1

Print

8

9

9

9

8

8

186

Print $ and Weight Unit on Label
0
No Print

1

Print

Clear Total Data by Server
0
Both Server and Client

1

Server

Tare Decimal Point Left Shift for SM-25 FIS3D
0
No
1
Yes

189

PLU Auto Delete
0
No Delete
1
15 Days

2
3

30 Days
90 Days

Swap Weight and Unit Price on Receipt
0
No

1

Yes

Default Item Code Equals to PLU Number
0
No
1

Yes

Nutrition Template
0
Standard
1
Simplified
2
Simplified Condensed

Standard Condensed
Tabulated
Tabulated Extra Condensed

192

193

194

Effective when SPEC158
= 1.

9

188

191

For UK only.

9

Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable
0
Disable
1
Enable

190

SM-100
8

30 lb to 15 kg Conversion
0
Disable

185

187

20 December, 2005

8

8

9

8
3
4
5

For U1 and CA only.

Nutrition Adjustment Feed
Enter value from range 0 to 255

8

Server IP Address
Enter a value between 1 to 254

9

For U1 and CA only.

For Client scale only.

12

Specification List

SPEC
NO.
195

196

197

198

199

200

201

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Weight Print for Non-weigh Item
0
No

1

Yes

Scale File
0
Disable

1

Enable

2

3 Alphabetic

1

Cent Off

2

32 sec

PLU Call Up Range
0
Disable

1

Enable

Sell by Date for Manual Mode
0
Programmed Sell by Date

1

Zero Sell by Date

Print Format of Month
0
Number
1
2 Alphabetic
FSD Saving Calculation
0
Net Value
FIS3000 Time Out
0
2 sec
1
8 sec

SM-100

9

8
For U1 only.

8

202

Printing of Item Label when Barcode Data Overflow
0
Print
1
No Print

9

203

Preset Keys Pages
0
1 Page
1
3 Pages by Toggle

9

204

205

2

3 Pages by Shift Key

Reference PLU Function Key Enable
0
Inhibit

1

Allow

Print Function Key Enable
0
Inhibit

1

Allow

8

206

Print Barcode when Right Side Data Overflow
0
No print
1
Print Barcode Digits

207

Weight Decimal Point Position for Barcode and Label Printing
0
Same as SPEC607
1
0.000

208

209

210

211

212

213

214

Network Time Out
0
3 sec
1
x2

2
3

x4
x10

FSD Calculation
0
Unit Price

1

Price Percentage Off

PLU Repeat Function Key Enable
0
Inhibit

1

Allow

Pick ‘N’ Pay Protocol
0
Old

1

New

8
Effective when SPEC607
= 2.

8
For U1 only.

8
For SF only.

8

Department Number for Pick ‘N’ Pay
Enter a value between 1 to 99

For SF only.

Flag Code Function Key Enable
0
Inhibit

1

Allow

DHCP Function
0
Disable

1

Enable

13

Specification List

SPEC
NO.
215

216

217

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
9

Centering of Special Message
0
Yes

1

No

JIS Code Table
0
New

1

Old

5
6
7
8

F5
F6
F7
F8

Default Label Format 2 for Item Printing
0
Not Used
1
F1
2
F2
3
F3
4
F4

SM-100

8

218

Zero Unit Price for Unit Price Change Function Key
0
Inhibit
1
Allow

219

Numeric Key Entry Reset
0
3 sec
1
5 sec

For AA only.

9
2

Disable

For AA only.

Item Barcode Right Side Data Dependent on Unit
0
Disable
1
Enable

8

221

Receipt with Tax Information Function Key Enable
0
Inhibit
1
Allow

8

222

Open Cash Drawer without Sales Function Key Enable
0
Inhibit
1
Allow

9

223

Negative Unit Price Function
0
Disable

8
1

Enable

FIS3000 Wire Type
0
4 wires

1

2 wires

Prepack Grand Total for Individual PLU
0
Yes

1

No

Reverse Calculation of ITF Check Digit
0
No

1

Yes

Unit Price Override Password Function
0
Inhibit

1

Allow

Individual PLU Total Transaction
0
No

1

Yes

Preset Key Group
0
Disable

1

Enable

Auto Print after PLU Call
0
No

1

Yes

220

224

225

226

227

228

229

230

Effective when SPEC1 =
0 or 2.

8

Effective when SPEC178
= 1.

9

Effective when SPEC150
= 1.

9

231

Zero Unit Price for PLU and Unit Price Override
0
Inhibit
1
Allow

9

232

Feed for Continuous Label
0
No

9
1

Yes

Time Format
0
24 Hours

1

12 Hours (AM/PM)

233

9

14

Specification List

SPEC
NO.
234

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Sub-total and Grand Total Barcode
0
Based on Item Barcode

SM-100
9

1

Based on Total Barcode

235

Mask Barcode Last Human Readable Check Digit
0
No
1
Yes

9

236

Character Generator for Korea
0
Old

8
1

New

Half-key Function
0
Inhibit

1

Allow

2

SM-25 Dots

237

238

239

240

241

242

243

244

FIS3000 Free Format Unit
0
mm
1
Dots

9

9

Cheque and Credit Payment Function Key
0
Inhibit
1

Allow

Voucher Payment Function Key
0
Inhibit

1

Allow

PLU Code for IR POS and TMR
0
6 Digits

1

7 Digits

Discount without Limit Function Key
0
Inhibit

1

Allow

Concatenate Commodity Name Display
0
No

1

Yes

Enable PLU Price Change Flag
0
No

1

Yes

8

245

Print Sell by Date or Used by Date when Date Equals Packed Date
0
Yes
1
No

246

Print First and Check Digits Outside Barcode
0
No
1

Yes

Print Packed date
0
Manual and Prepack Mode
1
Manual

2
3

Prepack Mode
No Print

Print Sell by Date
0
Manual and Prepack Mode
1
Manual Mode

2
3

Prepack Mode
No Print

Print Used by Date
0
Manual and Prepack Mode
1
Manual Mode

2
3

Prepack Mode
No Print

Centering Shop Name on Label
0
No

1

Yes

Shop Name on Receipt
0
Top

1

Bottom

Auto Reconnect when Server Down
0
Disable
1
Every 2 min

2
3

Every 3 min
Every 15 min

247

248

249

250

251

252

For KE only.

9

9

9

9

9

15

Specification List

SPEC
NO.
253

254

255

256

257

258

259

260

261

262

263

264

265

266

267

268

269

270

271

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Client Auto PLU Update
0
Update / Delete Existing PLU
1
Update / Delete All Sever PLU
2
Update Existing PLU

3
4

Update All Server PLU
Disable

Auto Update of Client Off-line Report
0
Disable

1

Enable

Retry Ethernet Communication
0
2 times

1

5 times

SM-100

8

Display Price with Tax after Clerk Key Press
0
Yes
1

No

For AA only.

Change Place Name to PLU via Function Key
0
No
1

Yes

For AA only.

Beef Labeling
0
No

1

Yes

Auto Print Sub-total Label in Prepack
0
No

1

Yes

Beef Labeling : Print Country
0
Code

1

Name

External Rewinder
0
Disable

1

Enable

Selection of Receipt / Label
0
Label

1

Receipt

FSD Net Value Minimum
0
Off

1

On

Print Ingredient Data on Next Label
0
Disable

1

Enable

Client Using Local Free Format Label
0
No

1

Yes

2

Exact Weight

1

Second Language

FSD Weight
0
Back Computed (Single Range)
1
Back Computed (Dual Range)
CPDL Language Selection
0
First Language

9

9

8

8

For U1 only.

8

Exclude AA, HK, CN, TW
and KE.

9
4
5
6
7

Individual Report Print and Clear in Z Mode
0
Disable
2
1
Manual Clear
Store Total Report Clear
0
Store Total Report Only

For U1 only.

8

Display Special Scale Message for Discounted Item
0
No
1
Yes
Auto Clerk Accumulation (for scanner)
0
No
1
V1
2
V2
3
V3

Always set to 1 for SM200.

1

V4
V5
V6
V7

For IR only.

Auto Clear

All Report

16

Effective when SPEC270
= 1 or 2.

Specification List

SPEC
NO.
272

273

274

275

276

277

278

279

280

281

282

283

284

285

286

287

288

289

290

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
9

Beef Reference Number
0
Code

1

Date

Item Code Follow PLU Number
0
Yes

1

No

Bench Key Pad
0
New

1

Old

Taiwan Receipt Printer
0
Disable

1

Enable

Floating Server
0
Disable

1

Enable

Real Time Buffer
0
No
1
2 Days
2
3 Days
3
4 Days

4
5
6
7

5 Days
6 Days
7 Days
Unlimited

3
4

By Date and Reference No.
By Date and PLU No.

U1 Self-service
0
Disable

1

Enable

Real Time Customer Number
0
No

1

Yes

Real Time Buffer Receipt
0
Detail

1

Total Only

Barcode Function
0
Without CR

1

With CR

Barcode Look-up-table (LUT) Contents
0
Non-weigh Item Only

1

All Items

Open Cash Drawer on Credit Payment
0
Allow

1

Inhibit

Australia ECR Function
0
No

1

Yes

Enforce Amount Tendered
0
No

1

Yes

Enforce Change Key
0
No

1

Yes

Planned Price Printed in Report
0
Enable

1

Disable

Repeat PLU Call
0
No

1

Yes

Payment Key
0
Disable

1

Enable

Traceability Report
0
Disable
1
By Reference No.
2
By PLU No.

SM-100

For IR only.

8

8
For TW only.
Apply for POS1 FLEX
PP2000 srs. 2 only.

9

9

8
For U1 only.

8

8

8

9

8
For AR only.

9

9

8

17

For DEC countries only.

Specification List

SPEC
NO.
291

292

293

294

295

296

297

298

299

300

301

SM-110 V1.20

SPECIFICATION DESCRIPTION

1

No Change

SM-200 Power Save
0
Back Light Off

1

Power Off

2
3

10 Min
2 Min

4
5
6

1 Min
2 Min
5 Min

SM-200 Battery Option
0
Yes

1

No

SM-300 Scrolling Message Update Rate
0
6 Lines

1

12 Lines

Ingredient File-Size Expansion
0
Maximum 99 records

1

Maximum 255 records

Print PLU Ingredient in Receipt
0
No

1

Yes

Traceability Update Function
0
No

1

Yes

2

80 Preset Keys

SM-500 Self-Service
0
No

1

Yes

Print Receipt after Accumulation
0
Yes

1

No

1

Enable

SM-200 Power Save Timeout
0
3 Min
1
5 Min
PLU Scrolling Message Display Interval
0
Disable
1
3S
2
10S
3
30S

Keyboard Selection
0
Normal Keyboard #
1
100 Preset Keys

Fixed Port Number for Ethernet
Enter value from 1 to 254

303

DHCP IP Address Lease Time
0
Disable

8

8

9

8

8

8
# 32/56 Preset Keys.
Identical to SPEC672.

8
96 Preset Keyboard.
Identical to SPEC688.

9

305

Character Spreading Speed Up
0
Disable

1

Enable

Unit Print on Receipt
0
Pcs

1

Items

Code Page
0
DOS

1

ANSI

SM-500 2nd Receipt Printer
0 Disable

1

Enable

Praxis Function
0
Disable

1

Enable

309

For SF only.

8

Server Port Number
Enter value from 1 to 254

308

For U1 only.

8

304

307

SM-100
9

Gap Value In-feed Operation
0
Re-adjustable

302

306

20 December, 2005

8
(S3, S4, M3 & M4)
For U1 only.

8
For IR only.

8

8

18

For DEC countries only.

Specification List

SPEC
NO.
310

311

312

313

314

315

316

317

318

319

320

321

322

323

324

325

326

327

328

329

330

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
Multi Barcode Type
0
EAN128
1
RSS

9
2

CODE128

Operator Logging Function
0
Disable

1

Enable

Price Change Password
0
Disable

1

Enable

Price Change Log File
0
Disable

1

Enable

2

Enable (Clerk Report)

1

No

Training Mode
0
Disable
1
Enable
Print PLU Traceability in Receipt
0
Yes

SM-100

For AI 01 only.

9
For CA only.

9
For CA only.

8
For DEC only.

8

9

Include Prepack Total in Manual Total Report
0
Yes
1

No

Wireless Communication
0
No

Yes

9
1

Wireless FTP Port Number
Enter value range from 1 to 9999

Not in used.

9

Delete Traceability Record
0
Yes

1

No

PLU Link to Text Field
0
Disable

1

Enable

Julian Date for Packed and Sell Date
0
No

1

Yes

Price Printing Size (Large Font)
0
No

1

Yes

Auto PLU Broadcasting
0
Disable

1

Enable

8
For U1 only.

8

Decimal Point For Unit Price And Total Price
0
Disable
1

Enable

Peel Sensor Value
0
Re-adjust

1

No Change

ON/Off Key
0
Disable

1

Enable

SM300 Print Control
0
Disable

1

Enable

TU 9 Digit Total Price
0
Disable

1

Enable

PLU Tare Call up
0
Allow

1

Inhibit

Individual Scale Store Total Report
0
No

1

Yes

8

8

8
For Tu only.

8

8

19

Specification List

SPEC
NO.
331

332

SM-110 V1.20

SPECIFICATION DESCRIPTION

1

Enable

ITEM Text (5-16) Print on Total Label
0
Disable

1

Enable

9

Image at Top Receipt
Enter range from 0 to 99

334

Image at Bottom Receipt
Enter range from 0 to 99

335

Traceability Eat By Date
0
Disable

1

Enable

Traceability Max Weight
0
Disable

1

Enable

5
6
7
8

F5
F6
F7
F8

1

EAN128

337

338

Traceability Default Label Format
0
Not Used
1
F1
2
F2
3
F3
4
F4
Traceability Barcode
0
EAN13

339

Flag Data (EAN13)
Enter range from 0 to 99

340

Enforce Scan
0
No

1

Yes

TVP2000 (SM300)
0
Not Send T10

1

Send T10 Label Format

LCD 1 Line Scroll
0
Disable

1

Enable

Clear Key in Prepack
0
Enable

1

Disable

Print Pack Date
0
Yes

1

No

Update Spec For Server/Client System
0
Enable

1

Disable

341

342

343

344

345

346

347

348

349

SM-100
9

Default ITF for Barcode
0
Disable

333

336

20 December, 2005

Update Label Turn-over In Receipt Buffer
0
No
2
1
Only In Registration Mode
3

Only In Prepack Mode
Both

Internet Broadcast
0
No

1

Yes

Taiwan POP Label
0
Disable

1

Enable

Direct Access To Clerk Mode
0
Disable

1

Enable

20

For TW only

Specification List

SPEC
NO.
350

351

SM-110 V1.20

SPECIFICATION DESCRIPTION
Additional Rounding In Receipt
0
Print

1

No Print

Gratuitous ARP
0
Disable

1

Enable

21

20 December, 2005

SM-100

Specification List

SPEC
NO.
400

401

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION

SM-100
9

Auto Power-Off Function
0
Inhibit
1
3 Minutes
2
10 Minutes

3
4
5

30 Minutes
1 Hour
3 Hours

RTS/CTS Handshaking of RS-232C
0
On

1

Off

9

402

Reset Receipt consecutive Number after Reset Report
0
No
1
Yes

9

403

Vender Number Display in Registration Mode
0
Allow
1

9
Inhibit

Number of Vender Keys
0
4 Vender Keys
1
5 Vender Keys

6 Vender Keys
7 Vender Keys

404

9
2
3

405

Priority of Shop Name and Special Message on Receipt
0
Shop Name Priority
1
Special Message Priority

9

406

Centering of shop name on Receipt
0
Allow

9

407

1

Inhibit

Centering of special Message on Receipt
0
Allow
1

Inhibit

9

408

One or Two Touch for Receipt Printing in AMT/TEND
0
One Touch
1
Two Touch

9

409

PLU Number Printing on Receipt
0
Inhibit

9
1

Allow

Sale Item Entry Method
0
Total

1

Item

410

411

412

413

414

415

416

417

9

9

Default Vender Transaction by Print Key
0
Allow
1

Inhibit

Print Checking Line
0
Print

1

No Print

Source of Used by Date
0
Current Date

1

Packed Date

9

9

In-Store Barcode for Barcode Scanner Enter
0
F1F2 CCCCCC TTTT CD
5
1
F1F2 CCCCC TTTTT CD
6
2
F1F2 CCCC TTTTTT CD
7
3
F1F2 CCC TTTTTTT CD
8
4
F1F2 CC TTTTTTTT CD

9
F1F2 CCCCC XCD TTTT CD
F1F2 CCCC XCD TTTTT CD
F1F2 CCCCC PCD TTTT CD
F1F2 CCCCC 0 TTTT CD

#1: F1F2 - 20~29
#2: CC ~ CCCCCC Item code.
#3: TTTT ~ TTTTTTTT
Total Price

9

Non-PLU Item Enter by Barcode Scanner
0
Allow
1

Inhibit

Barcode Scanner
0
Allow

1

Inhibit

Centering of Commodity Name on Label
0
Allow
1

Inhibit

9

9

22

Specification List

SPEC
NO.
418

419

420

421

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
9

Weight Data Synchronization Function
0
Allow

1

Inhibit

Open Cash Drawer when Issue Label
0
Allow

1

Inhibit

Print Grand Total on Sales Report
0
Allow

1

Inhibit

2

Receipt Data & Label Data

Constitution of Report
0
Receipt Data
1
Label Data

SM-100

9

9

9

422

Currency Symbol for Total Amount on Receipt
0
No Print
2
Suffixation
1
Prefixion

9

423

Print Total Number of Pieces on Receipt
0
Allow
1

9

424

425

426

Inhibit

Total Barcode on Receipt for Total Price in 2nd Currency
0
Allow
1
Inhibit

9

Second Currency as Reference Price
0
No
1
For Receipt

9
2
3

For Label
For Receipt and Label

Print Tare Weight when Unit Price is 0
0
Allow

1

Inhibit

For FR only.

9

427

Eliminate Cash Line on Receipt when No change Operation
0
Allow
1
Inhibit

9

428

PRINT Tax List on Receipt
0
Allow

9
1

Inhibit

Non-Weigh PLU Unit Price Display
0
Total Price Column

1

Unit Price Column

429

Effective when SPEC603
=1

9

430

Items on PLU / Main Group / Dept / Tax Report
0
Registered Items
1
All Items

9

431

Eliminate Vender Data on Sales Report
0
Allow

9

432

1

Font Size for Commodity Name on Receipt
0
Standard Font Size
2
1
Larger Font Size

Inhibit
9
Largest Font Size

433

Condition of Additional Price Rounding for Total Price
0
Cash Payment Only
1
Always

9

434

Item Barcode Type
0
EAN Type
1
ITF Type

9

435

Total Barcode Type
0
EAN Type

2

User Programmable

1

ITF Type

9

436

In-Store Barcode Type for Barcode Scanner Enter
0
EAN Type
1
ITF Type

9

437

Print Rounding on Receipt
0
Allow

9
1

Inhibit

23

Specification List

SPEC
NO.
438

439

440

SM-110 V1.20

20 December, 2005

SPECIFICATION DESCRIPTION
9

Print Sub-Total on Receipt
0
Allow

1

Inhibit

Pulse width for Opening Cash Drawer
0
20ms (Default Value)
1
50ms
2
100ms

3
4
5

200ms
300ms
400ms

2

Power On & Password R Key

R Mode Password Function
0
Inhibit
1
Password R Key

SM-100

9

9

441

Set / Reset Auto PLU Call Function Key Enable
0
Allow
1
Inhibit

9

442

Change Main Group Code for Auto Plu Call Function Key Enable
0
Allow
1
Inhibit

9

443

Prefix Fixed Code to PLU Code for Auto PLU Calling
0
No
2
2 Digits
1
1 Digit
3
3 Digits

9

Decimal Point Position for Second Currency
0
None
2
1
0.0
3

9

444

0.00
0.000

445

Unit Price Change for PLU after Label Printing
0
Inhibit
1
Allow

446

Print Tare Weight on Receipt
0
Allow

447

448

449

450

451

452

453

454

455

Effective when Spec39 =
1, Spec40 = 0

9

1

Inhibit

Place Change for PLU after Label Printing
0
Inhibit
1

Allow

Sell Date Change for PLU after Label Printing
0
Inhibit
1

Allow

For KE only.

Trace Auto Clear
0
Inhibit

1

Allow

For KE only.

Trace per PLU
0
Inhibit

1

Allow

For KE only.

Trace Auto Update
0
Inhibit

1

Allow

For KE only. Effective
when Spec450 = 1.

Trace Confirm
0
Inhibit

1

Allow

For KE only.

Trace C/D Check
0
Inhibit

1

Allow

For KE only.

9
For KE only.

9

9

Forced Tare when Tare Value in PLU is 9999
0
Inhibit
1

Allow

Printing of Servings Fact
0
SS Top & SC Bottom
1
SS Bottom & SC Top

SS Print Only
SC Print only

For CA only.

9
2
3

24

For CA only.

SM-110 Flexible Barcode Setting Guide
Operation

Display
tare

weight

S1

-- -->

S46

-- -->

Unit price/kg

Remark

price

Press [mode] third
PLU FILE

Enter programmer.

times
Enter
Press numeric 4 and 6

Flexible

Barcode

FLEXI BARCODE
programme.

Press [*]

S46.0

F BAR

0

NO SET

Program Flexible Barcode.

Enter numeric 1

S46.0

F BAR

1

NO SET

Program Flexible Barcode 1.

Press [*]

S46.1

F BAR

0

FLAG

Program Flag Code.(0 for F2,1
for F1F2,2 for non.)
Press [*]

S46.2

F BAR

0

ITEM CODE

Enter item code length.
Enter data format for DATA1.( 0
for weight,1 for quantity,2 for unit

Press [*]

S46.3

F BAR

0

DATA1

price.3 for weight/quantity,4 for
total price,5 for original price,6 for
user programmable.)

Press [*]

S46.4

F BAR

0

DIGIT

Enter DATA1 length.
Shift for DATA1.( 0 for no right
shift,1 for right shift, 2 for right

Press [*]

S46.5

F BAR

0

SHIFT
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.)
Enter data format for DATA2.( 0
for weight,1 for quantity,2 for unit

Press [*]

S46.6

F BAR

0

DATA2

price.3 for weight/quantity,4 for
total price,5 for original price,6 for
user programmable.)

Operation

Press [*]

Display
tare

weight

Unit price/kg

price

S46.7

F BAR

0

DIGIT

Remark

Enter DATA2 length.

Shift for DATA2.( 0 for no right
shift,1 for right shift, 2 for right
Press [*]

S46.8

F BAR

0

SHIFT
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.)
Press [ⅹ] to select the middle

Press [*]

S46.9

F BAR

NO MIDDLE CD
check digit.
Press [ⅹ] to select the last check

Press [*]

S46.1

F BAR

NO LAST CD
digit.
Press [ⅹ] to swith ITF and EAN

Press [*]

S46.1

F BAR

ITF BARCODE
barcode.

Press [#]

S46

-- -->

FLEXI BARCODE

Save the flexible barcode 1.

Note: See the Flexible Barcode Usage Note at 《3.6.1 PLU programming》 in SM-110 Operation
manual.

SM-110 Traceability Setting Guide
Prepare
¾

Set SPEC258 to “1”

Traceability Programming

Operation

Display
Unit price/kg

price

Remark

tare

weight

[Mode] [Mode] [Mode]

S1

Æ

PLU FILE

[3] [4]

S34

Æ

COUNTRY FILE

[*] [1]

S34.0

[*][C][H][I][N][A]

S34.1

COUN

[#]

S34

Æ

COUNTRY FILE

Save Country No. 1

[3] [5]

S35

Æ

CUTTING HALL

Enter cutting hall programming

[*] [1]

S35.0

HALL

1

NO SET

[*][1]

S35.1

HALL

1

COUNTRY

Program cutting hall country No. 1

[*][C][U][T]

S35.2

HALL

CUT

Name 3

Program cutting hall name “CUT”

[#]

S35

Æ

Enter S mode

Enter country file programming

1

NO SET

Program country No. 1

CHINA

Name 5

Program country name “CHINA”

CUTTING HALL

Program cutting hall No. 1

Save cutting hall No. 1

Operation

Display
tare

weight

Unit price/kg

price

S36

Æ

SLAUGHTER

HOUSE

Remark
Enter

[3][6]

slaughter

house

programming

[*][1]

S36.0

HOUSE

1

NO SET

[*][1]

S36.1

HOUSE

1

COUNTRY

Program slaughter house No. 1

Program slaughter house country
No.1
Program slaughter house name
[*][S][L][A][U][G]

S36.2

HOUSE

SLAUG

NAME 5
“SLAUG”

[#]

S36

Æ

[4][7]

S47

Æ

[*][1]

S47.0

KIND

1

NO SET

Program kind file No. 1

[*][M][E][A][T]

S47.1

KIND

MEAT

NAME 4

Program kind name “MEAT”

[#]

S47

Æ

KIND FILE

[4][8]

S48

Æ

CATEGORY FILE

[*][1]

S48.0

CATEG

1

NO SET

Program category No. 1

[*][B][E][E][F]

S48.1

CATEG

BEEF

NAME 4

Program category name “BEEF”

[#]

S48

Æ

SLAUGHTER

HOUSE

Save slaughter house No. 1

KIND FLIE

Enter kind file programming

CATEGORY FILE

Save kind file No. 1

Enter category file programming

Save category file No. 1

Operation

Display
Unit price/kg

Remark

tare

weight

price

[4][9]

S49

Æ

[*][1]

S49.0

BREED

1

NO SET

Program breed file No. 1

[*][B][U][L][L]

S49.1

BREED

BULL

NAME 4

Program breed name “BULL”

[#]

S49

Æ

BREED FILE

[3][7]

S37

Æ

TRACEABILITY

[*][1]

S37.0

TRACE

1

NO SET

Program traceability No. 1

[*][1]

S37.1

TRACE

1

BORN

Choose born country No. 1

[*][1]

S37.2

TRACE

1

FATTEN

Choose fatten country No. 1

[*][1]

S 37.3

TRACE

1

S HOUSE

Choose slaughter house No. 1

[*][1]

S37.4

S CNT

1

LNK 1

BREED FILE

Enter breed file programming

Save breed file No. 1

Enter traceability programming

Choose link country No. 1 for
slaughter house

[*][1]

S37.5

TRACE

1

C HALL

[*][1]

S37.6

C CNT

1

LNK 1

Choose cutting house No. 1

Choose link country No. 1 for
cutting hall

[*][1]

S37.7

TRACE

1

ORIGIN

Choose original country No. 1

Operation

Display

Remark

tare

weight

Unit price/kg

price

[*][R][C][D]

S37.8

R-CD

RCD

NAME 3

Program R-CD content “RCD”

[*][G][T][I][N]

S37.9

GTIN

GTIN

NAME 4

Program GTIN content “GTIN”

[*][L][O][T]

S37.10

LOT

LOT

NAME 3

Program LOT content “LOT”

[*][1]

S37.11

TRACE

1

KIND

[*][1]

S37.12

TRACE

1

CATEG

Choose category No. 1

[*][1]

S37.13

TRACE

1

BREED

Choose breed No. 1

[*][C][O][N][T]

S37.14

CONT

CONT

NAME 4

Program cont content “CONT”

[*][0][6][0][3][1][0]

S37.15

TRACE

060310

EAT D

Program eat by date “06/03/10”

[*][5][0][0][0]

S37.16

TRACE

5.000

WEGHT

Program maximum weight “5kg”

[*][S][C][D]

S37.17

S CD

SCD

NAME 3

Program S CD content “SCD”

[*][S][N][M]

S37.18

S NM

SNM

NAME 3

Program S NM content “SNM”

[*][S][A][D][1]

S37.19

S AD1

SAD1

NAME 4

Program S AD1 content “SAD1”

[*][S][A][D][2]

S37.20

S AD2

SAD2

NAME 4

Program S AD2 content “SAD2”

[#]

S37

Æ

TRACEABILITY

Choose kind No. 1

Save traceability No. 1

Free Format Programming
¾
¾

Enter “S12 Æ FREE FORMAT”, press [*]
Edit the correlative items for traceability in free format

PLU ITEM Programming
¾
¾

Enter “S19 Æ PLU ITEM”, press [*]
Set “ Item TRACE” to “PROGRAM” and press [#] to save

PLU Programming
¾
¾
¾

When you edit PLU, set “S1.64 PLU” to “TRACE ALLOW” and press [*]
Input traceability number and press [#] to save
In the end, when you call the PLU and print label, you’ll see the traceability
information on the label

SM-110 Nutrition Fact Setting Guide
Concept
Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).

Setting Method
1.
2.
3.
4.
5.
6.

7.
8.
9.
10.
11.
12.

Enter S mode
Enter “S19 --- PLU ITEM” and set “IMAGE” and “NUTRI” to “PROGRAM”
Enter “S12 --- FREE FORMAT”
Enter “S12.5 IMG 1 Å 47 F ITEM” to “S12.5 IMG 10 Å 56 F ITEM” to set the print
area of Nutrition. (In each label format, totally you can print 10 images)
Enter “S1 --- PLU FILE” to create PLU.
Enter “S1.50 PLU
0 IMAGE 1” to choose the template number for IMAGE 1
(From No. 70~ No. 81).
…
Enter “S1.59 PLU
0 IMAGE 10” to choose the template number for IMAGE 10
(From No. 70~ NO. 81).
Set “S1.81 PLU
PRINT NUTRI” to set nutrition print status to “Print”.
Enter from S1.82 to S1.10 to input nutrition contents.
For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands.
Enter “S12 --- FREE FORMAT” to set up the TXT position.
Press [PLU] key to save.

Operational Menu Tree
—

Registration Mode ( R Mode )

— Report Print Mode ( X Mode )

X1.1
X2.1
X3.1
X4.1
X5.1
X6.1
X7.1
X8.1
X3.2
X4.2
X5.2
X8.2
X1.4
X2.4
X3.4
X4.4
X5.4
X6.4
X9.4
X4.3

— Programming Mode ( S Mode )

S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22

Read Main Group Daily
Read PLU Daily
Read Department Daily
Read Sales Daily
Read 24 Hour Daily
Read ABC Daily
Read Clark Daily
Read Pre-pack Department Daily
Read Department Monthly
Read Sales Monthly
Read 24 Hour Monthly
Read Pre-pack Main Group Daily
Read Main Group Term
Read PLU Term
Read Department Term
Read Sales Term
Read 24 Hour Term
Read ABC Term
Read Tax
Read Store Summary
PLU File……
Department File
Main Group File
Key Assignment
Shop Name File
Advertisement Message
Vender File
Date and Time
Special Message
Ingredient File
Text File
Free Format……
Scroll Message
Scroll Sequence
Place File
Machine Setting
Logo File
Tax File
PLU Item……
Memory Status
I/F Test
File Load

1

¾ S1 PLU File

S1.0
S1.1
S1.2
S1.3
S1.4
S1.5
S1.6
S1.7
S1.8
S1.9
S1.10
S1.11
S1.12
S1.13
S1.14
S1.15
S1.16
S1.17
S1.18
S1.19
S1.20
S1.21
S1.22
S1.23
S1.24
S1.25
S1.26
S1.27
S1.28
S1.29
S1.30
S1.31
S1.32
S1.33
S1.34
S1.35
S1.36
S1.37
S1.38
S1.39
S1.40
S1.41
S1.42
S1.43
S1.44
S1.45
S1.46
S1.47
S1.48

Enter PLU No.
Unit Price (PR-KG or PR-PCS)
Label Format 1 (Default, T1-T12, S, A-C, F1-F99)
Label Format 2 (No, F1-F99)
Commodity Name and its Font Size
EAN Barcode or ITF Barcode
Barcode Type
Flag Code
Item Code
Item Code (Lower 4 Digits)
Right Side Data of Item Barcode
Selection of EAN Add-on
Main Group Number
Print Sell by Date or Not
Sell by Date [Enabled when S1.13 is set to print]
Print Sell by Time or Not
Present or Key-in [Enabled when S1.15 is set to print]
Sell by Time [Enabled when S1.16 is set to Key-in]
Print Used by Date or Not
Used by Date [Enabled when S1.18 is set to print]
Print Packed Date or Not
Packed Date [Enabled when S1.20 is set to print]
Print Packed Time or Not
Present or Key-in [Enabled when S1.22 is set to print]
Packed Time [Enabled when S1.23 is set to Key-in]
Cost Price
PLU Tare
Unit Symbol
Quantity
Type of Volume Discount
The 1st Target of Volume Discount
The Discount Value for the 1st Target
The 2nd Target of Volume Discount
The Discount Value for the 2nd Target
Print Type of Discount Price (Mark Down)
Schedule of Volume Discount (The Start Date)
Schedule of Volume Discount (The Start Time)
Schedule of Volume Discount (The End Date)
Schedule of Volume Discount (The End Time)
Selection of Discount Day of the Week
Special Message Number
Ingredient Number
Special Message (Program Original Special Message)
Ingredient (Program Original Ingredient)
Place of Production
Coupled PLU Number
Tax Number
Reference PLU Number
Proportional Tare

2

¾ S12 Free Format

S12.5 Free Format Item

S12.0
S12.1
S12.2
S12.3
S12.4
S12.5
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.

Free Format Number
Label Width
Label Height
Label Angle
Label Type (Item Label or Total Label)
Free Format Item……
PLU Number
Price
Unit Price
Weight
Quantity
Packed Date
Packed Time
Commodity
Quantity Unit
Sell by Date
Sell by Time
Barcode
Shop Name
Discount
Used by Date
Logo
Main Group Code
Department
Scale Number
Ingredient
Special Message
Frame 1
Frame 2
Tare
Clerk
Text 1
Text 2
Text 3
Text 4
Text 5
Text 6
Text 7
Text 8
Text 9
Text 10
Text 11
Text 12
Text 13
Text 14
Text 15
Text 16

3

¾ S19 PLU Item

Label Format 1 [LABFR1]
Label Format 2 [LABFR2]
Barcode Selection [BACODE]
Barcode Flag Data [FLAG]
Barcode Item Code [ITCODE]
Main Group Code [MGCODE]
Sell by Date [SELLDT]
Sell by Time [SELLTM]
Used by Date [USEDDT]
Packed Date [PACKDT]
Packed Time [PACKTM]
Cost [COST]
Tare [TARE]
Quantity [QTY]
Quantity Unit [Q .UNIT]
Discount Status [DISCNT]
Discount Schedule Date [SCH DT]
Discount Schedule Time [SCH TM]
Mark Down Status [MARKDN]
1st Target for Discount 1 [1STLMT]
2nd Target for Discount 2 [2NDLMT]
Special Message Number [SMGNUM]
Ingredient Number [INGNUM]
Commodity Name [COMNAM]
Special Message [SP MG]
Ingredient [INGR]
Place of Production [PLCNUM]
Image [IMAGE]
Bonus [BONUS]
Nutrition [NUTRI]
ITF Selection [ITFSEL]
Reference PLU [REFPLU]
Security PLU [SECPLU]
Coupled PLU [COUPLU]
Discount Day of the Week [DAY WK]
EAN 5 Digit Add-on [ADD-ON]
Tax Number [TAX]
2nd Price [PRICE2]
Proportional Tare [% TARE]
Customer Discount [CUSDIS]
Restaurant Discount [RESDIS]
Staff Discount [STADIS]
Traceability Discount [TRACE]
Storage Temperature [TEMP]
Pack. Indicator [PACK.I]
Multi Barcode 1 [M1BARC]
Multi Barcode 2 [M2BARC]
Total Multi Barcode 1 [TM1BAR]
Total Multi Barcode 2 [TM2BAR]
Unit Price Selection [U.PRIC]
PLU Scroll (U1 only) [PLUSCR]
PLU Linked Text Field [PLUTEX]
4

— Reset Report Mode ( Z Mode )

Z1.0 Reset Sales Daily
Z2.0 Reset Sales Monthly
Z3.0 Reset Sales Term

5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 147
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4e48beeb-8f19-469b-bdb1-5a076a4ae80f
Producer                        : Acrobat Distiller 6.0 (Windows)
Modify Date                     : 2012:08:24 13:42:11+08:00
Create Date                     : 2012:08:24 13:38:40+08:00
Metadata Date                   : 2012:08:24 13:42:11+08:00
Document ID                     : uuid:2fb77c24-6c44-4dde-8823-2217faa5e9c0
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools

Navigation menu