Hardware List VP & SP Doors 7020/7040 E02Pyropanel
User Manual: 7020/7040
Open the PDF directly: View PDF .
Page Count: 18
Download | ![]() |
Open PDF In Browser | View PDF |
Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors INTRODUCTION Hardware items listed are approved for Pyropanel VP and SP Series doorsets. This approval does not apply to other door types. The list is updated regularly but includes obsolete items which are listed for reference purposes. Refer to website www.pacificdoors.co.nz for the most up-to-date list. All items indicated in the list as [PDS] must be factory installed or prepared for by Pacific Door Systems Ltd. Hardware for F0.5 doorsets is listed separately. 1. MECHANICAL LATCHES Note: For fire doors to comply with AS/NZS 1905.1 the following conditions apply to latches: • No non-self-latching functions are permitted, including deadlock bolts • Materials for essential latching components must have a melting point of: - For integrity up to and including 120 min not less than 890oC - For integrity in excess of 120 min not less than 1030oC 1.1 CYLINDRICAL OR TUBULAR LOCKS AND LATCHES Make Code AH 2000-100 series 1 VP120 Boyd LE series 1 VP240 Carbine EA 3000 series 1 VP240 Corbin 400, 1400 1 VP240 Corbin 6600 VP120 Corkey 800 KT VP240 Dorma CL600 VP240 Efco 1000 1 VP240 Efco 5300 1 VP240 EZSET EA3000 1 VP240 EZSET 100EA, 104EA VP240 EZSET RA series VP240 Falcon S 452 DL 1 VP240 Gainsborough 840 SS, GOV, CV 1 VP240 Gainsborough 4000 series VP240 Gainsborough 4300 VP240 Gainsborough 4500 series VP240 Gainsborough 4600 series VP240 Gainsborough 4700 series VP240 Goal UH series Hafele 1200 VP240 Ilco Unican Model EA3000 VP240 Ilco Unican 6000 series VP240 Ilco Unican Model 3700 VP120 Kaba KL series VP240 Kwikset 411 B, C, G, WL VP120 © 2008 Pacific Door Systems Ltd Note 1 Max.Rating VP240 1 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 1.1 CYLINDRICAL OR TUBULAR LOCKS AND LATCHES CONTINUED. Make Code Note Max.Rating Laidlaw Thomson AD series 1 VP240 Lane 3000, 3100 series 1 VP240 Legge G2 series Lemaar Montoro, Denia Lockwood 500 Lockwood 530 Lockwood 930-950-970-990 VP240 Lockwood 1300 series KNK VP120 Lockwood 5200 VP120 Lockwood 5300 1 VP240 Lockwood 7000, 7020, 7040, 7070 1 VP240 Lockwood 110 combination lock 1 VP240 Lockwood NX5 and NX6 1 VP240 Lockwood Nexion NF22, NF12 MCM 500 1 VP120 Nara HL 4000 Series 1 VP240 Nara HL 8300 Series 1 VP240 Posse B300 1 VP240 Posse C100 SS series VP240 Posse C300 SS series VP240 Premiapri N14PB VP240 Schlage A and AL Series 1 VP240 Schlage D Series 1 VP240 Schlage F series VP120 Schlage S Series VP240 Schlage TH885 VP240 Schlage Z series VP120 Showa SS G25 VP120 Stanley Byron 32 VP60 Stronglok LHS1082 with Vinco C-70 FDL VP180 Vinco CL7000 Weiser A530 VP240 Wilka 3000 VP120 Yale 5300 VP240 1 VP240 VP120 1 VP240 VP240 1 1,2 VP240 VP240 1.2 MORTICE LOCKS AND LATCHES Make Code Note Abloy 2595 1 Abloy 3000 series © 2008 Pacific Door Systems Ltd Max.Rating VP240 VP240 2 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 1.2 MORTICE LOCKS AND LATCHES CONTINUED. Make Code Abloy EL580 series VP240 Abloy 4291 VP240 ABS 1100 series Accord CH-382 VP120 Accord CH-382 SS VP240 Astra 430-439 Boyd ML Chubb 3R35X CISA 52300 VP120 CISA 52760 VP240 Corbin Series 9200, 9500, models –01, -51, -54, 55 VP120 Corbin Series 9400, 9700, 9700T Models –10, -51, -54, -55, -57 VP240 Corbin Series 9800 models –51, -54, -55, -57 VP240 Dorma ST9600 series (excluding 9603 deadlock) VP240 Efco 3000 1 VP240 Efco 8000 series 1 VP240 Erebus E900, E901, E951, E954, E957 VP120 Falcon M and LM2000 series Models 2100,2380,2410,2520,2560,2580 VP120 Gainsborough 1000 series 1100, 1400, 1500, 1900 Gainsborough 3000 series 3400, 3500, 3900 VP120 Glutz 4728, 4828, 4738, 4838 VP240 Goal AS-1 7 VP120 Goal UC-1 7 VP240 Goal UCC; GC Cup Handle VP240 Hafele 2500 VP240 Hafele 2595 with Dialock furniture VP120 Hafele 911.23.270 VP240 Hafele 911.03.181 with Dialock DTSH terminal VP240 Kaba MS mortice lock VP240 Lanetronics E335 Lane Astra 430-439 VP240 Legge 990 series VP240 Legge Ingersoll Rand PRO5596-990 keypad / lever furniture with 990 mortice lock VP60 Legge E800 – Models E800, E801, E802, E803, E851, E852, E853, E857 VP120 © 2008 Pacific Door Systems Ltd Note 1 1 Max.Rating VP120 VP240 VP240 1 10 1 VP240 VP240 VP240 3 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 1.2 MORTICE LOCKS AND LATCHES CONTINUED. Make Code Note Max.Rating Legge E900 – Models E900, E901, E951, E954 VP120 Lockwood Electric Access Deadlatch VP240 Lockwood 570, 572, 574 VP240 Lockwood 3570 and 3570E series incl. digital furniture VP240 Lockwood 3670 series Securilock VP240 Lockwood M8600 VP240 Lockwood 8000 series VP240 Lockwood Digital Access Locks DGT530, DGT572DL, DKO572DL, DKOLKO572DL VP240 MIWA UXAL3H VP240 MIWA AL5HA Card Lock (with auto deadbolt) VP180 AL5H series with deadbolt removed Modric HD99 – Models 9960, 9962, 9970, 9990 VP120 Novas 6000 series VP120 Padde XS VP180 Pennine E900 Models E900, E901, E951, E954, E957 VP120 Pennine 800 Models 800, 801, 802, 803, 806, 851, 852, 853 VP120 Russwin 5000 series with Saflok Mark 5 or Saflok Micro Card card key furniture VP120 Saflok Mark 5 Card Key Lock 1, 8 VP240 Saflok Micro Card Key Lock 1, 8 VP240 Saflok ME, MS, MT series VP180 Schlage M series (except Deadbolts or devices fitted with hold back function) VP240 Schlage L – Models 9010, 9040, 9050, 9060, 9070, 9080, 9082 VP240 Showa 535-15 VP120 Showa LL VP120 Tesa 2035 VP120 Tesa / Onity HT24 card operated VP120 Union 2642, 2657, 2677, 26773, 2370 Vingcard Models 1040, 1050, 1060, 1080, 1090, 2100, 3000, 3500 Euro or ANSI lockcase VP240 Vingcard DV80 series Presidio VP240 Weider 5750 VP240 Winkhaus 2501 series VP240 Wilka 207 VP240 Yaletronic 1100 VP180 © 2008 Pacific Door Systems Ltd 9 VP120 4 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 1.3 RIM AND SURFACE MOUNTED LOCKS AND LATCHES Make Code Note Efco 506, 507 VP120 Lockwood 001 double cylinder automatic deadlatch VP240 Lockwood 001/002 combination set VP120 Padde GK Escape latch Rivers Model D, 2 and 4 point locks using sexbolts VP240 Surelock McGill Multiple Bolting system with auto latching VP240 3 Max.Rating VP240 [PDS] [PDS] 1.4 ROLLER LATCHES Make Code Note Max.Rating Clifton Roller latch 4 VP30 DA [PDS] Kevdon Roller latch 4 VP30 DA [PDS] Legge (Erebus) 1511 4 VP30 DA [PDS] Sopers SP15201 4 VP30 DA [PDS] UDM FR Roller latch 5,6 VP240 [PDS] Notes: 1. The latch sets indicated might have either steel or brass strike bolts, strikers, or bolt retaining plates. Steel is rated VP240 while brass is rated VP120. 2. Plastic striker box not permitted on Yale 5300 3. With steel through-bolt fixings 4. The Clifton, Kevdon, Legge and Soper Roller latches may only be used with VP30 Double Action (DA) doorsets in timber frames (including VP30-DA Heritage). 5. The UDM Roller latch may be used with Double or Single Action frames 6. The UDM Roller latch may be the sole means of latching (Head latching or Stile latching) in VP series hinged doorsets. 7. Timber knobs or plastic levers not permitted. 8. In conjunction with any approved mortise lock. 9. Only used in pair doorsets if no taller than 2200mm 10. The locksets must be installed with three holes through the face, one 12.7mm in diameter and two 6.5mm diameter holes 21mm either side 2. POWER BOLTS Make Loktronic Code Locking Bolt (Fail Secure) Trimec ES8000 V-lock Notes: Max. Rating VP240 VP120 VP240 Note 1 2 3 [PDS] [PDS] 1. Device is rated VP240 as a supplementary locking device only 2. Device is rated VP120 as a sole latching device, but must be fitted with a brass change of direction block. Only approved with fail-secure or power-to-open function. Device must be fitted with a bevelled bolt or electrically wired to hold the bolt retracted until the door leaf has closed 3. Power-To-Lock (PTL) with supplementary latching. Power-To-Open (PTO) can be sole latching device. © 2008 Pacific Door Systems Ltd 5 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 3. ELECTRIC LATCHES Type: C = Cylindrical; M = Mortise Make Accord Corkey Lane Lockwood Code Digital Latch Bolt Series 800KT Lanetronics E335240 3570 Series Electric with conventional or digital furniture 990MFE Electron UXAL 3H 5000 with Saflock Mk5 Card Key M Series electric Intellis TH885 D Series electric Unican 1000 Series, L1000 Series, EE1000 Series Legge Miwa Russwin Schlage Schlage Schlage ILCO Notes: Type C C M M M M M M C C C Max. Rating VP30 VP240 VP240 VP240 VP240 VP240 VP120 VP240 VP240 VP240 VP120 [PDS] [PDS] 1. Steel latch bolts rated VP240, Brass rated VP120. 2. For installation of wire-ways in door leaf [PDS] is required. 3. Latches in fail-safe mode require auxiliary latching. UDM Roller Head latching is recommended. 4. ELECTRIC STRIKES Make Adams Rite EFF-EFF Gainsborough Harcor Honeywell Honeywell Lockwood Loktronic Padde Padde Rofu Trimec Von Duprin Von Duprin Notes: Code 7800 Series 43 KI ES1000 series 50/12/C RS 2-75959 Alpha RS 2-75959 EK 35 500 Series DKS Strike ES100 series ES110 series ES200 and ES2000 series ES700 and ES7000 series MT110 1400 or 3400 Series TS100 TS110 TS200 and TS2000 TS700 and TS7000 ES 3100 3041 or 3042 6211 Max. Rating VP90 VP240 VP240 VP240 VP120 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP120 VP240 VP240 VP240 VP240 VP240 VP120 VP120 1. “Fail Safe” electric strikes are only approved if the door closer is fitted to the opening or hinge face of the leaf. 2. All strikes are approved only in steel jambs. © 2008 Pacific Door Systems Ltd 6 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 5. MAGCLAMPS Make Efco Efco Guardsman HFH Lockwood Loktronic Loktronic Locknetics Padde Rixon Firemark Rixon Firemark Rofu Securiton Trimec Von Duprin Notes: Code GI 300 & GI 300D (VP60 without seal to head of leaf; VP120 with seal; VP240 with seal and fusible screw fixing) GI 200 (VP60 without seal to head of leaf; VP240 with seal to head of leaf) MES series 10000 Series – 10000, 10002, 10010ECO, 10030, 10050, 10060-ECO-D GI 200, GI 300, GI 300D as for Efco GI 1710 Slimline ZB1710 Slimline, ZB1710 Models 268, 280, 290, 350, 390 Models CCW30, EML2H, EML2HD, EML6, EML10, EML11, EML12 1700, FM1710 ZBFM1710 8011-LC or 8022(pair) 62 Magnalock Z series 1200 series, DS4010, DS4020, DD4010 Max. Rating Up to VP240 Note 1-3 Up to VP240 VP60 VP240 1-3 1-3 1-4 VP240 VP60 VP240 VP60 1-4 1-3 1-4 1-3 VP240 VP60 VP240 VP240 VP240 VP240 1-4 1-3 1-4 1-4 1-3 1-4 1. Approved for both timber and steel jambs. For installation in timber jambs [PDS] is required. In timber jambs the magclamps body may be housed into oversize stops or located between lengths of stop. 2. Electromagnet must be connected to jamb not door leaf. “Z” bracket installation is only rated VP60. All-steel connectors must be used. 3. Auxiliary approved mechanical latch is required with all magclamps 4. For installation on VP90-240 doors [PDS] is required. 6. SHEARLOCKS Make Locknetics Von Duprin Notes: Code GF3000 series 700 Series (Obsolete model) Max. Rating VP30 VP30 [PDS] [PDS] 1. Device must be used in conjunction with an auxiliary mechanical latch set 2. Shearlock may only be fitted to 48mm leaf in a steel-framed doorset, and to a special modified head in a timber framed doorset, both for 30 minutes fire resistance. 7. HOLD OPEN DEVICES Make Dorma Dorma LCN Code A50, A70, AW50, AT50, AT70 armatures associated with EM-50 and EM-70 series electromagnetic hold open devices. MAG, MAW, MAT armatures for Dorma EM series SEM7830 © 2008 Pacific Door Systems Ltd Max. Rating VP240 VP60-DA VP240 7 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 8. HINGES Type Butt Broad Butt Rising Butt Butterfly Lift-off Strap Continuous Restrictions Make Model Material Ajax 100 x 100mm Classic 100 x 100 Ball Bearing Stainless Steel Dalco 321 100 x 100mm Stainless Steel Efco EF10025SSFPBB Efco SS Ball bearing Stainless Steel Glutz SS Ball bearing Stainless Steel Hafele 926.84, 926.89 HK SS90044B30 Stainless Steel Kingsway 100 x 100 2.5mm Stainless Steel Laidlaw Thompson 100 x 100 3mm Stainless Steel Lane 100 x 100 2.5mm Steel Lockwood HS 100x100 Lockwood SUS304 100x100 McKinney TB 100 x 100 Steel or S/S Nara D10 100x100 3mm S/S Nara All metal spring hinge 100x100 Nikon 100 x 100 Stainless Steel Pyropanel Surface mount 100x70 2.4mm Stainless Steel Schlage 413, 100 x 100 2.5mm Stainless Steel Schlage 417, 100 x 100 3mm Stainless Steel SCL SUS-304, 102x102mm Stainless Steel Stanley PB780, SW781, BB783 Stainless Steel Trio 100 x 100 Mild or Stainless Steel Yank 100 x 100 3mm Brass 100h x 125w S/S 3mm thick Schlage 411, 100 x 75 (Note 3) Surelock S2 / HA2 / 130 x 75 Nara D10 / 100 x100 Stainless Steel UDM 127 x 100 Stainless Steel Tuff TUI Ball bearing steel/ 250mm Steel or Stainless steel continuous hinge at least 1.6mm thick, leaf width not less than a 100 x100 butt hinge, fixed with screws in a staggered pattern at not less than 200mm centres. Max. Rating VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP120 VP240 VP240 VP240 VP240 VP240 (Note 4) VP60 VP240 VP240 VP240 VP240 VP240 VP120 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] 1. Brass hinges or screws are generally not approved. Brass plated steel is approved 2. May only be used as a centre hinge or as an additional hinge of 3 or 4 and must be used in conjunction with Nara D10 hinges to accommodate lift. 3. Brass hinge is limited to FRR60 minutes in steel frames for leaf sizes up to 1.95m2 and FRR 30 minutes in timber frames. © 2008 Pacific Door Systems Ltd 8 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 9. OTHER ELECTRONIC ACCESSORIES Device Microswitch Keep Reed Switch Power Transfer Notes: Make Abloy Chubb GRI-Telemark Sentrol 1076, 1077, 1078, 1076C, 1077C, 1078C Tane Alarm SD-70, SD-80 Abloy 8810 and 8811 Lead Cover Abloy EA280 & EA281 Lead Cover Lane Flexitran Lockwood PWRLEAD Lockwood power transfer hinge Loktronic McKinney TA or TB Series Schlage PT1 Von Duprin EPT 218 & EPT 1024 Notes 3 3 3 3 2 2 1 1 3 Max. Rating VP30 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] 1. Only rated VP30 in timber frame 2. Where timber frames are used a layer of Intumex L is to be glued to the inside base of the lead cover channel 3. May only be used in a steel frame 10. SELF LATCHING PAIR HARDWARE FOR INACTIVE LEAF Make Dalco Lockwood Glutz Glynn Johnson Schlage UDM UDM UDM Weider Winkhaus Yank Restrictions: Type DC1851 chain bolt 530 or 930 or 950 Deadlatch GDS-0148-A-SS FB41T or FB41B Autolatch D Model 14-043 FR Roller Latch Autobolt Chain latch Model 180 Flushbolt Flushbolt Note 2 3 Max. Rating VP240 VP120 VP240 VP30/VP60 VP120 VP240 VP240 VP240 VP240 VP240 VP120 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] 1. All are approved for timber and steel jambs. 2. These deadlatches are installed in the door head with an appropriate snib (The Lockwood 8530-57SC is recommended). Backset length should be 70mm minimum. The deadlatches are rated VP60 for door leaves taller than 2400mm. 3. VP60 in steel jambs only. © 2008 Pacific Door Systems Ltd 9 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 11. SEQUENCE SELECTOR FOR PAIRS Make Briton DCI Dorma Dorma Dorma Efco Gainsborough Glynn Johnson Hafele Lane Lockwood / Efco Newstar Ryobi Tiki Weider Code Closerite 600 SR390 SR391, SR392, SR393 TS93 GSR system 3000 & 4000 3350SS COR 931.71.900 5230, 5180, 5305, 2359, 2369 3000 & 4000 SF-250F RB-34 S1991 DS-2800, DS-3600 Max. Rating VP240 VP240 VP240 VP60 VP120 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 Note: Sequence Selectors are required on pair doorsets with non-self-latching functions such as rebated meeting stiles or central locking. 12. SECURITY ACCESSORIES Make Type Code Chubb Hinge Bolt WS12 Chubb Hinge Bolt WS7 Duo Hinge Bolt HBC, HBW Securicraft Securichain MC41 Notes: Notes Max.Rating VP60 2 VP240 3 VP120 [PDS] VP240 [PDS] 1. Up to 2 hinge bolts may be used, set into the leaf near the top and/or bottom hinges 2. Steel jambs only 3. Rated VP60 in Drywall and VP120 in concrete/masonry installation 13. SURFACE MOUNTED CLOSERS Note: • Fixture of surface-mounted closers to Pyropanel mineral fibre board cored fire doors requires selftapping screws, which must penetrate at least 32mm into the leaf. • Cushioned backcheck function is required on all closers for compliance with AS/NZS 1905.1. All listed closers comply with this requirement. • Hold open devices are required on certain fire doors for compliance with NZ Building Code C/AS1 3.17.9. Requirements for fire detection to release hold-open devices are given in C/AS1 3.17.10. • For fire doors on escape routes, NZBC C/AS1 requires closers to be adjustable to satisfy the requirements for maximum forces required to open the door, set out in C/AS1 Appendix C 8.1.2. Make Abloy Abloy Accord Code Modul 230 series DC240 90 © 2008 Pacific Door Systems Ltd Maximum Rating VP240 VP240 VP240 10 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 13. SURFACE MOUNTED CLOSERS CONTINUED Make Code Arrow 7x7 Series Surface mounted Boyd/Axim Boyd/Axim Boyd/Axim Boyd Sentronic 1500BC 1024 Series 7000/1000BC 4010/4110 Briton Briton Briton Briton Briton Briton Briton Corbin Delta Doric Dorma Dorma Dorma Dorma Dorma Dorma Dorma Dorma Dorma Dorma Dorma Dorma 81 series 121.5 series 220 1000 series 2000 series 2508S 5000 500 series 70BC Series DK53 TS68 TS73F Series TS71 TS72 without hold open TS73 EMF TS73 EMR TS73 V-F TS77 Series TS83 Series TS90 TS92 without hold open Dorma Dor-o-matic Efco Efco Gainsborough Gainsborough Gainsborough Gainsborough Geze (Hafele) Geze (Hafele) Geze (Hafele) Global Glutz Hafele TS93 series incl. EMF or EMR TS97 SC60, SC80 4080 Series 1300 Series 3000 series 3200 series 3050/3060 3100 TS2000V BC series TS4000, TS4000DA series TS5000, TS5000L, TS5500 series 70BC series PDC-500, PDC-730, PDC-770, PDC-830 DCL51, DCL55, DCL110 © 2008 Pacific Door Systems Ltd Maximum Rating VP90 plastic cover, VP240 metal cover VP120 VP90 VP120 VP90 plastic cover, VP120 metal cover VP120 VP120 VP240 VP120 VP120 VP120 VP120 VP120 VP120 VP120 VP240 VP240 VP240 VP240 VP120 VP120 VP240 VP240 VP120 VP240 VP120 VP120 VP120 VP240 VP120 VP240 VP240 VP120 VP120 VP240 VP240 VP120 VP120 VP120 VP240 VP90 11 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 13. SURFACE MOUNTED CLOSERS CONTINUED Make Code HFH 60 BC series Justor CH series Kaba 702 SIL King D70 BC, D70 P BC series King 600 BC, 600 P BC series King 900 BC series Lane 70 BC series Lane SL 65 BC LCN 524, 523T LCN 4310 ME series LCN 1070 series 1460 series 4010, 4110, 4040 series Sentronic 4010/411 SE Leado 980 series C999 EM hold open to any Lockwood Lockwood closer Lockwood 3024 series Lockwood 414 / 426 series Lockwood 409 series Lockwood 713 series Lockwood 714 / 726 series Lockwood 724 series Lockwood 1300 series Lockwood LW 1730 series Lockwood LW 1830 series Lockwood LW 2000 series Lockwood LW 2500 series Lockwood 7714 / 7724 series Lockwood 7726 series Lockwood Miwa M200 Lockwood Miwa M800 Lockwood 8002 Door Operator MAB 400 series MBC 525 BC series MBC 527 BC series Newman Tonks NT 121 BC Newstar 80 Nikon 90 NHN 1080 series Novas 1000 BC Novas (Guardsman) 1300 BC Novas (Guardsman) 1500 BC © 2008 Pacific Door Systems Ltd Maximum Rating VP120 VP240 VP120 VP240 VP120 VP120 VP120 VP120 VP 240 VP90 All VP90 with plastic cover, VP120 with metal cover VP240 VP240 VP240 VP120 VP120 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP120 VP240 VP60 VP120 VP240 VP120 VP240 VP120 VP240 VP120 VP240 VP240 VP120 12 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 13. SURFACE MOUNTED CLOSERS CONTINUED Make Code Novas (Guardsman) 3000 BC Pyropanel TS77 Series Ryobi 7000 Series Ryobi 70 Series Ryobi 90 Series Ryobi 1500 BC Series Ryobi 1550 BC Series Ryobi D-2550 DA series Ryobi D-3550 series Sabre BC730 series: models 732, 733, 734 Sabre Models 735, 736 Sabre 836 AS Sabre 2100 B series Spartan 1002-BC Tiki 80 series, 90 Vinco DC67 Vinco DC934 Weider 1000 series Weider 1500 BC series Yale 2000 series Yale Yank Maximum Rating VP240 VP240 VP120 VP120 VP120 VP120 VP90 plastic cover VP240 VP240 VP240 VP120 VP240 VP240 VP240 VP120 VP120 VP240 VP240 VP120 VP90 plastic cover VP240 metal cover VP120 VP240 3501 series BC1002AS 14. CONCEALED CLOSERS Make Arrow Briton Corbin Dorma Dorma LCN LCN Lockwood Newstar Tiki Notes: Type 7x7 Series 531 500 ITS-86 ITS-96 without hold open 3030 Series 330 409/091 CL60 60 1. 2. 3. 4. 5. 6. Notes 1 1 3 1 Max. Rating VP120 VP60 VP120 VP180 VP180 VP240 VP240 VP240 VP240 VP240 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] Installation approved in steel jambs only (where noted) Only surface mounted arm brackets may be used with timber jambs (except see Note 3). Either surface mounted or mortised arm brackets may be used with steel jambs. Mortised arm may be installed in timber jamb in Heritage VP30 Series doors. Leaf glazing directly below concealed closers is not permitted except in VP30 Series Heritage fire doors Concealed closers are not recommended in exterior doors. Rating VP120 applies where door height exceeds 2400mm. © 2008 Pacific Door Systems Ltd 13 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 15. PANIC EXIT DEVICES Type Rod/Latch Rod/Latch Rim Latch Mortice Latch Restrictions: Make Adams Rite Briton Dorma Glutz JPM Lionheart Lockwood Lockwood Lockwood Massoud (MBC) Trident Weider Von Duprin Adams Rite Boyd JPM Lockwood Lockwood Massoud (MBC) Von Duprin Adams Rite Lockwood Von Duprin Weider Code 3100 373, 374, 377, 378, 379 PHA 2102/2203 (3 point latching only) 8600 9300, 9400 E9801, E9802 520V 5510 and 5530 series 9000 571 series 1089 3730, 3731 Series 2227F, 8827F, 9827F, 9927F 3700 ED22F 9000, 9100 520 9000 570 Series 22F, 88F, 98F, 99F 3300 9000 8875F, 9875F, 9975F 8909 Note 4 4 5 4 4 3 3 3 Max. Rating VP240 VP240 VP120 [PDS] [PDS] [PDS] VP240 VP240 VP240 VP240 VP240 VP240 VP60 VP240 VP240 VP240/VP60 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] VP240 VP60 VP240 VP240 VP240 VP60 VP240/VP60 VP240 VP240 VP240/VP60 VP240 [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] [PDS] 1. VP Series fire doors – All devices are surface-fixed and must be mounted using at least nominal 5mm steel hex bolts passing through the leaf. 2. All devices in VP Series fire doors may be fitted to doorsets with timber or steel jambs (except see Note 5) 3. Models without the F suffix have brass components and are therefore only rated 60 minutes. 4. Device may only be used in conjunction with a fire rated mortice or tubular latch or lockset. Fire resistance is then dependent on the fire resistance of the latch or lockset. 5. Steel frame only. Length adjustment mechanism for the vertical actuating rods must be fitted with a nylon screw. © 2008 Pacific Door Systems Ltd 14 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 16. DOUBLE-ACTION HARDWARE Device Make Roller latch Kevdon Clifton Soper SP15201 Legge (Erebus) 1511 FR Roller latch UDM Locking Abloy EL414 Electric Lock 8 Abloy EL415 Electric Lock Head Spring [PDS] [PDS] [PDS] [PDS] VP120 [PDS] VP60 [PDS] 7 VP60 [PDS] Loktronic Power Bolt 1 VP120 [PDS] Trimec ES8000 V-lock 9 VP120 [PDS] Dorma RTS85 VP120 [PDS] Lockwood Efco OTC series VP120 [PDS] Lockwood 9800 series VP120 [PDS] VP120 [PDS] VP120 [PDS] Notes: 5 Dorma BTS80F Dorma BTS75 Panic Exit Lock 3 3 3 3 Max.Rating VP30 VP30 VP30 VP30 Ryobi 30 series Floor Spring Notes VP30 [PDS] Dorma EMB 3 VP120 [PDS] Lockwood Efco EF840 (FS 840) VP120 [PDS] Lockwood 7310/7410 VP120 [PDS] Lockwood 7750 series VP120 [PDS] MAB 7312, 7412 4 VP120 [PDS] Surelock McGill Multiple Bolt B1 6 VP120 [PDS] 1. The Loktronic Power Bolt should be integrated with a fire detection system so that the bolt disengages on an alarm or power failure (fail safe or power-to-lock mode). In this mode the lock requires an auxiliary UDM roller latch. 2. A roller latch is required with double action doorsets. The UDM roller latch is standard 3. These items are approved only for VP30-DA in timber jambs with special requirements 4. VP120 with steel arms, VP60 with brass arms 5. Ryobi 30 series is limited to models without hold-open and with cushioned backcheck function. 6. Fitted with solid lower latch bar and hollow upper latch bar. Requires fitting of roller restraint auto-bolting mechanism and associated head ramp. 7. Abloy EL415 (fail unlocked) installed in the frame head, requires a modified strike plate to the head of the door leaf and an auxiliary UDM roller latch. 8. Abloy EL414 (fail locked) installed in the frame head, requires a modified strike plate to the head of the door leaf but does not require auxiliary latching and may not meet egress requirements. 9. Power-To-Lock (PTL) with supplementary latching. Power-To-Open (PTO) can be sole latching device © 2008 Pacific Door Systems Ltd 15 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 17. DOOR OPERATORS Make Abloy Ditec Ditec Dorma Dorma Dorma LCN LCN LCN Lockwood Notes: Type DA361 swing door operator Transit UE Wel E CD80 Door Operator ED200 Door Operator ED800 Door Operator 4611, 4622 autoequaliser 4630 / 4640 autoequaliser 4820 auto equaliser door operator 8002 series, transom mounted Notes 1 2 2 3 4 4 5 6 7 Max. Rating VP120 VP60 VP60 VP240 VP240 VP240 VP120 VP240 VP120 VP240 1. Modifications to installation are required – contact distributor www.levco.co.nz. Local fire or smoke detection is required either side of doors. 2. In timber-framed door only. Modifications are required to the standard installation - a fire door package is available from the distributor www.doormaticsnz.co.nz. Local fire or smoke detection is required either side of doors. 3. Transom mounted; fitted to a steel plate, or with long screws into lintel 4. Special conditions apply for fixing this closer. Closer may only use standard arm and may only be mounted on the push side of the leaf. Operator must revert to closer in the event of fire exposure 5. Modifications to installation required. Autoequaliser must revert to self-closure on local detection of smoke or heat from fire. 6. Modification of operator to include steel mounting plate is required 7. Latching of door leaf must prevent inadvertent operation of opener during fire exposure. 18. VIEWING LENSES Make ABUS Chubb Chubb Doorscope ERA Hafele HH Hotel Gong system Lane Lockwood Nikon Pyropanel Schlage Yank Note: Type 2200 8V001, WS8, WS13 WS9 DS-1000 959.06.002 and .008 Model B-03 Model 006 160 Security Door Viewer 2200, 2180, 2170, 2160 Panaramic DV004 Models 2160, 2170, 2180, 2200 Notes 1 Max.Rating VP240 VP120 VP60 VP60 VP240 VP240 VP240 VP240 VP240 VP240 VP240 VP120 VP240 VP240 [PDS] 1. Special factory fitting methods are required for the Doorscope DS-1000. © 2008 Pacific Door Systems Ltd 16 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 19. DOOR EDGE SEALS Make Code Max. Rating Firepro FP1212 VP240 Firepro FP1515 VP240 Lorient FDBU20 Intumescent sill seals VP240 Lorient HP4002 intumescent perimeter seal VP240 Lorient IS7010si VP240 Lorient IS7020si VP240 Lorient IS7025si VP240 Lorient IS7080si VP240 Lorient IS7085si VP240 Lorient IS8010si VP240 Lorient IS8011si VP240 Lorient IS8020si VP240 Lorient IS8085si VP240 Lorient IS8090si VP240 Lorient IS8091si VP240 Lorient LE1212 VP240 Lorient LE1515 VP240 Pacific Door Systems Acoustic Compression Seal (bottom edge) VP60 [PDS] Pyropanel Euroseal VP120 [PDS] Pacific Door Systems PFS-3 VP240 [PDS] Pacific Door Systems TP390 VP60 [PDS] Raven RP4T VP240 Raven RP8 VP240 Raven RP10 & RP10Si VP240 Raven RP23 VP240 Raven RP24 VP240 Raven RP25 VP240 Raven RP38 & RP38Si (rebated or surface-fixed) VP240 Raven RP39 VP240 Raven RP60 VP240 Raven RP78 and RP78Si VP240 Raven RP93Si VP240 Raven RP99Si VP240 Raven RP114 Sill gap seal VP240 Raven RP120 VP240 Raven RP150 VP240 © 2008 Pacific Door Systems Ltd [PDS] [PDS] [PDS] 17 Datasheet: E02 Date: 3-03-08 HARDWARE LIST – Pyropanel Fire Doors 20. FIRE RESISTANT GLAZING Insulation Rating Make Maximum Specification with Integrity Rating DTI Film Overlay FW60/VP240 - [PDS] NEG Firelite VP30 / FW30-1 / FW30-2 / VP60 / FW60 - [PDS] Georgian Wired VP120 / FW60 / FW30-1 / FW30-2 - [PDS] Georgian Wired Clear Laminated Float VP30 / FW30-2 - [PDS] Schott Robax VP240 / FW30-1 / FW30-2 - [PDS] Schott Pyran VP120 / FW30-1 / FW30-2 - [PDS] Schott Vycor VP240 - [PDS] Pyroceram VP240 / FW60 / FW120 - [PDS] Pyrobel 16 FW30-1 / VP30 / VP60 30 [PDS] Restrictions: Datasheets for FW30-1 and FW30-2 should be consulted for further information on approved glazing © 2008 Pacific Door Systems Ltd 18
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2008:03:03 09:08:34+13:00 Create Date : 2008:03:03 09:08:30+13:00 Metadata Date : 2008:03:03 09:08:34+13:00 Producer : Acrobat Distiller 8.1.0 (Windows) Format : application/pdf Creator : Pacific Door Systems Ltd Title : Hardware List VP & SP Doors Document ID : uuid:28bd6578-b3a1-40fd-b89e-a0da8472c6ff Instance ID : uuid:d2f5bbf4-0e85-4d67-85be-dbefc04496e5 Company : Pacific Door Systems Ltd Part : 1 Conformance : B Page Count : 18 Page Layout : OneColumn Author : Pacific Door Systems LtdEXIF Metadata provided by EXIF.tools