FERROLUX®
FLG 50-P / FLG 200-P
Audio frequency generator for cable
and pipeline detection, sheath and
cable fault location

Benefits:
Powerful, yet compact generator
Signal Select – dependable pipe location
even with other cables in close proximity
Multi-frequency operation – 3 frequencies
transmitted simultaneously
Description

Technical Data

The FERROLUX Measuring System allows operators of power
and telecommunication cables as well as public utility companies for gas and water supply, to solve a wide variety of problems. This Audio Frequency Generator can be used for cable
and pipe location, cable fault location and cable identification.
®

A new feature in the FERROLUX range is the ability to transmit three frequencies simultaneously, allowing to select the
best receiver frequencies during locating without the need to
return to the FLG generator to change frequencies here, too.
®

Frequencies

491 Hz / 982 Hz / 8440 Hz
(user-specific frequencies on
request)
Multi-frequency operation

Output power
FLG 200

power
0 … 10 W
0 … 200 W
0 … 10 W
0 … 50 W

FLG 50

increment
0.5 W
10 W
0.5 W
2.5 W

Impedance matching

0.5 … 1000 Ω, automatically

Measured parameters

loop impedance,current,
voltage

Power supply

mains operated
100 … 240 V AC

Interfaces

RS-232

There is no overheating of the generator in continuous
operation when feeding capacitive loads (insulated gas pipes)
or inductive loads (shorted cables).

Anti-deep discharge
protector

for internal battery

Dimensions ( W x L x H)

450 x 320 x 133 mm

The output power can be adjusted to two levels: low (up to
10 W) and high (up to 50 / 200 W)

Weight

approx. 12 kg

Operating temperature

- 20 °C … + 50 °C

Enclosure protection

IP 20

In conjunction with the Audio Frequency Receiver FLE 10,
the system can be used for implementing the new position
loca-ting mode SuperMax and the SignalSelect method
of identifying the direction of signal flow. The instrument
measures and displays the loop impedance of the object
under test, output voltage and current and phase angle.

All benefits at a glance
Backlit LCD for all important parameters
Automatic impedance matching
Manual and automatic frequency selection
Multi-frequency operation - three frequencies transmitted
simultaneously
Power levels 10 W / 200 W (FLG 200), 10 / 50 W (FLG 50)
for fine adjustment at low power
Overload protection in all impedance ranges
Indication of hazardous output voltage on contact
Protection against ext. voltage with indication
Wide range power supply with power factor correction
(PFC)
RS-232 PC interface for easy and straight forward service
19” housing available in two versions – portable or for
cable van installation
SebaKMT · Dr.-Herbert-Iann-Str. 6 · 96148 Baunach/Germany · Tel. +49(0) 95 44 - 6 80
Fax +49(0) 95 44 - 22 73 · sales@sebakmt.com · www.sebakmt.com

Versions
FLG 200-P
FLG 200-M 19”M
FLG 50-P
FLG 50-M 19”

portable
for installation in cable test vans
portable
for installation in cable test vans

Accessories
Mains cable
Cable kit

ISO 9001:2000

NKG 1
VL FLG 200

Technical data subject to change without notice.
LFT_FLG 50/200_eng_2006_33



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:045aa593-974e-4c07-bff1-c0e368e08b44
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Create Date                     : 2006:08:18 09:00:42+02:00
Modify Date                     : 2006:08:18 10:48:02+02:00
Metadata Date                   : 2006:08:18 10:48:02+02:00
Creator Tool                    : Adobe InDesign CS2 (4.0.3)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10976 bytes, use -b option to extract)
Instance ID                     : uuid:456570b3-2e87-11db-aa4a-000d9333118a
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:e8b7abff-2d05-11db-8a1d-f5adbc9155c0
Derived From Instance ID        : 19eb148e-29f2-11db-b6e3-e873fe5dd421
Derived From Document ID        : adobe:docid:indd:7e3dc276-29e2-11db-b6e3-e873fe5dd421
Format                          : application/pdf
Creator                         : Adobe InDesign CS2 (4.0.3)
EXIF Metadata provided by EXIF.tools

Navigation menu