Fire Protection General Products Catalogue
User Manual: Fire Protection General Products Catalogue
Open the PDF directly: View PDF .
Page Count: 88
Download | |
Open PDF In Browser | View PDF |
Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the broadest lines of fire protection system equipment worldwide. Continually expanding its capabilities through aggressive research and product development, it provides its customers effective fire protection and construction solutions for residential, commercial, industrial, and institutional buildings. Tyco Fire & Building Products serves a diverse group of specifiers, including architects, engineers, contractors, and associated industries with a nationwide network of distribution and manufacturing facilities. Tyco takes pride in the introduction of new and innovative products, technologies and product application extensions. With over 150 years in the industry, Tyco Fire & Building Products is uniquely qualified to provide and develop cost effective solutions customized to any building configuration and fire protection application. Our patented solutions provide significant performance advantages with lower installation and maintenance costs. Tyco Fire & Building Products also offers the industry’s most complete fire protection design software package through its SprinkCAD® programs. Table of Contents AUTOMATIC Sprinklers Standard Spray Sprinklers . . . . . . . . . . . . . . . . . 7 – 10 Extended Coverage Sprinklers . . . . . . . . . . . . 11 – 16 Storage Sprinklers . . . . . . . . . . . . . . . . . . . . . . 17 – 22 Rapid Response™ Sprinklers . . . . . . . . . . . . . . 23 – 26 Dry Sprinklers . . . . . . . . . . . . . . . . . . . . . . . . . 27 – 30 Special Purpose Sprinklers . . . . . . . . . . . . . . . 31 – 36 Sprinkler Accessories . . . . . . . . . . . . . . . . . . . . 37 – 38 Nozzles & Nozzle Accessories . . . . . . . . . . . . . 39 – 42 System Valves & Devices Wet System Valves & Devices . . . . . . . . . . . . . 43 – 46 Dry System Valves & Devices . . . . . . . . . . . . . 47 – 50 Deluge & Preaction Systems . . . . . . . . . . . . . . 51 – 56 General Purpose Valves . . . . . . . . . . . . . . . . . . 57 – 60 Specialty Items . . . . . . . . . . . . . . . . . . . . . . . . 61 – 64 PIPING & Electrical Products Grooved Piping Products . . . . . . . . . . . . . . . . 65 – 68 CPVC Pipe & Fittings . . . . . . . . . . . . . . . . . . . 69 – 70 Electrical Devices . . . . . . . . . . . . . . . . . . . . . . 71 – 76 Specialty Systems Foam Systems . . . . . . . . . . . . . . . . . . . . . . . . . 77 – 82 Aquamist® Systems . . . . . . . . . . . . . . . . . . . . . 83 – 85 T Yco Fire & Building Products Leading the Way for More than 150 years In 1881, industry pioneer Frederick Grinnell patented the first “sensitive” automatic fire sprinkler incorporating a number of features still found in modern day units. Since that time, many of the major advancements in fire sprinkler technology can be attributed to Grinnell and other leading names in the industry that are now part of Tyco Fire & Building Products. The history of our company is one of tremendous growth through organic development and acquisition with over 150 years in the industry, to create a single powerful global resource for owners, and those to whom they turn for engineering advice and support. Today our company is proud to be associated with our corporate and legacy brands that continue to operate on the cutting edge of fire protection innovation, mechanical applications and product performance. We stand behind every product we manufacture by offering the industry’s only 10-year limited warranty*, that’s up to ten times longer than our competitors’ warranties. (Full warranty details can be found on all of our current product technical data sheets, or at our website at www.tyco-fire.com.) All metric measurements throughout this catalog are based on U.S. standard-to-metric conversions. Metric specifications may vary from country to country. We Cover All The Action Fire Protection General Products Catalog Tyco Fire & Building Products The industry leader Best-in-class solutions start with best-in-class technology, and only Tyco Fire & Building Products offers more of both. That’s how we are able to simplify installation and improve the performance of fire protection and mechanical systems, providing the owner with the lowest installed cost. Here are just some of the industry-leading technologies we have developed: • Extended Coverage Ordinary and Light Hazard Fire Sprinkler Technology • The First Residential Sprinklers for Life Safety Purposes • Electronic Quick Opening Accelerator for Dry Sprinkler Systems • Back-to-Back CPVC Fittings for Residential Fire Protection • Sprinkler System Design Software (SprinkCAD) and Fluid Delivery Time Calculation Software In addition, Tyco Fire & Building Products provides turnkey Engineered Systems’ a choice of fully integrated solutions focused on specialty applications in Europe, the Middle East, the Americas, and Asia/Pacific, including: • Pump/Valve Skid Packages • Water Mist Systems for Fire Protection • Valve Packages for Seawater and Harsh Environments Tyco Fire & Building Products has made a commitment to the world-class performance of its products and, as a result, has received independent approvals and certifications from industry agencies globally. Our state-of-the-art international manufacturing facilities have all been granted ISO 9000 approvals, and are routinely audited by independent testing agencies for quality and conformance. We also participate in more than 70 National Fire Protection Association committees and a number of international standards and code-making bodies. FM Underwriters Laboratories Inc. Underwriters Laboratories Inc. for use in Canada T yco Fire & Building Products Scientific Services Laboratory Verband der Schadenversicherer Factory Mutual Research Corporation Loss Prevention Certification Board in association with AB & Lloyds Fire Protec tion General Products Catalog T yco F i r e & B u i l d i n g P r o d u c t s • Storage Fire Protection Solutions such as K-14, K-25 and K-17 ESFR Technology. It was the first of the ESFR technology, and we pioneered it. Standard Spray Sprinklers a p p l icatio n s : responses: standard and quick. Together they offer a wide range of sprinklers from which to choose when designing a standard coverage fire sprinkler system. Standard Response Sprinklers are intended for use in fire sprinkler systems designed in accordance with the installation rules recognized by the applicable Listing or Approval agency. There are two types or response elements: bulb and solder. Series TY-B bulb type sprinklers are available in a variety of attractive finishes that blend well with their surroundings. When in service, a small bubble in the fluid contained in the bulb compensates for normal temperature changes. When heated, the fluid in the bulb expands and shatters the bulb, allowing water to be discharged. Series TY-L solder type sprinklers employ a link whose two sections are joined by solder with a predetermined temperature rating. Heat absorbed by the link is conducted directly to the soldered joint. When the solder melts, the link springs apart, releasing water that strikes the sprinkler deflector. T yco Fire & Building Products • Office Buildings • Banks • Factories • Libraries • Theaters • Light & Ordinary Hazard Occupancies • Schools Quick Response Sprinklers are designed with a 3mm bulb or small nickel link to react more quickly at the specified temperature. They are available in pendent, upright, recessed, concealed, vertical sidewall, and horizontal sidewall styles. The narrow profile bulbs and attractive finishes of the Series TY-FRB provide specifiers with a wide variety of sprinklers for use in quick response applications. The versatile Quick Response TY-FRL Series provides the specifier with a solder type sprinkler for most commercial and industrial applications. Fire Protec tion General Products Catalog Standard Spray Sprinklers Standard Spray Sprinklers are comprised of two Au to mat i c S p r i n k l e r s Standard Spray Sprinklers T Y-B Upright, Pendent & Recessed Pendent • All hazard • 5 mm bulb • Discharges a hemispherical water spray pattern in the area beneath the sprinkler • Small frame, narrow profile bulb K Factor K=5.6 (80,6), K=8.0 (115,2) 1 3 Thread Size ⁄2" NPT • ⁄4" NPT Escutcheon Style 10 • Style 40 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY3151, TY3251, TY4151, TY4251, TY4851, TY4951 Tech Data TFP151 Horizontal, Recessed Horizontal & Vertical Sidewall • Light hazard/Ordinary hazard K Factor • 5 mm bulb Thread Size ⁄2" NPT • Small frame Escutcheon Style 10 • Unique deflector design of the horizontal sidewall sprinkler results in smaller profile Escutcheon finish White Coated, Chrome • Designed for installation along a wall or on the side of a beam just beneath a smooth ceiling Sprinkler Finish Natural Brass, Chrome Sta n da r d Sp r ay Sp r i n k l e r s • Water discharge is directed primarily outward and downward in a quarter spherical pattern • Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position K=5.6 (80,6) 1 Plated, Brass Plated Plated, White Polyester, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY3351, TY3451 Tech Data TFP161 • Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics T Y-FRB Upright, Pendent & Recessed Pendent • Light hazard/Ordinary hazard light hazard K=2.8 (40,3) K Factor K=2.8 (40,3) • K=4.2 (60,5) • 3 mm bulb Thread Size 1⁄2" NPT • 3⁄4" NPT • Hemispherical water spray pattern in the area beneath the sprinkler Escutcheon Style 10 • Style 20 • Small frame and narrow profile bulb enhance appearance Escutcheon finish White Coated, Chrome K=5.6 (80,6) • K=8.0 (115,2) Style 30 • Style 40 Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester, Lead Coated SIN TY1131, TY1231, TY2131, TY2231, TY3131, TY3231, TY4131, TY4231, TY4831, TY4931 Tech Data TFP171 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s Standard Spray Sprinklers T Y-FRB Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall • Light hazard/Ordinary hazard K Factor K=5.6 (80,6) • 3 mm bulb Thread Size ⁄2" NPT • Designed for use in applications where aesthetics must be considered or where building construction makes the installation of standard pendent or upright sprinklers impractical Escutcheon Style 10 • Style 20 • Vertical sidewall sprinkler can be installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling 1 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester, Lead Coated SIN TY3331, TY3431 Tech Data TFP176 RFII “Royal Flush II” Pendent Concealed • Light hazard/Ordinary hazard K Factor K=5.6 (80,6) • 5 mm bulb (standard) 3 mm bulb (quick) Thread Size ⁄2" • Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration Plated, Natural Brass Plated, White Polyester Painted, Custom SIN TY3551, TY3531 Tech Data TFP181 Sprinkler Finish Cover Plate: Chrome • Internally threaded closure with 1 ⁄2" (12,7 mm) of adjustment • Available with optional dust and air seal T Y-L Upright, Pendent & Recessed Pendent • All hazards • Solder type • Discharges a hemispherical water spray pattern in the area beneath the sprinkler K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 Thread Size ⁄2" NPT • 3 ⁄4" NPT Escutcheon Style 20 • Style 30 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY3111, TY3211, TY4111 TY4211, TY4811, TY4911 Tech Data TFP110 Sta n da r d Sp r ay Sp r i n k l e r s • Separable, two-piece design of the mounting cup and cover plate allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling 1 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog Au to mat i c S p r i n k l e r s Standard Spray Sprinklers T Y-L Horizontal Sidewall • Light hazard / Ordinary hazard K Factor K=5.6 (80,6) • Solder type Thread Size ⁄2" NPT • Suited for hotels, nursing homes and hospitals Sprinkler Finish Natural Brass, Chrome • Design allows piping to be confined to corridors, closets or service areas 1 Plated, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY3311 Tech Data TFP120 T Y-FRL Upright, Pendent & Recessed Pendent • Light hazard/Ordinary hazard light hazard K=2.8 (40,3) • Solder type • Typically used in hotels, motels, office buildings and other commercial and industrial applications K Factor K=2.8 (40,3) • K=5.6 (80,6) K=8.0 (115,2) 1 3 Thread Size ⁄2" NPT • ⁄4" NPT Escutcheon Style 20 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated SIN TY1121, TY1221, TY3121 TY3221, TY4121, TY4221 Tech Data TFP130 Sta n da r d Sp r ay Sp r i n k l e r s Horizontal Sidewall • Solder type K Factor K=5.6 (80,6) • Light hazard/Ordinary hazard Thread Size ⁄2" NPT • Designed for compact installation along a wall or on the side of a beam just beneath a smooth ceiling Sprinkler Finish Natural Brass, Chrome • Generally used in lieu of pendent or upright sprinklers because of aesthetics, building construction or economic considerations Tech Data TFP140 1 Plated SIN TY3321 T Y-QRF Flush Pendent • Solder type K Factor K=5.6 (80,6) • Light hazard/Ordinary hazard Thread Size ⁄2" NPT • Features separable escutcheon with 3 ⁄8" vertical adjustment Escutcheon finish Chrome Plated, White 1 Polyester, Black Sprinkler Finish Chrome Plated, White Polyester, Black SIN TY3261 Tech Data TFP190 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 10 Fire Protection General Products Catalog Tyco Fire & Building Products a p p l icatio n s : Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra hazard occupancies. Extended coverage sprinklers are available in both standard response (EC) and quick response (QR-EC). They are available in upright, pendent, horizontal sidewall and recessed horizontal sidewall. These sprinklers are typically used in hotels, restaurants, office buildings, warehouses, and other areas where it is desirable to reduce the overall number of required sprinklers. T yco Fire & Building Products • Office Buildings • High-Piled Storage • Hotels • “Big-Box” Retailing • Hospitals • Libraries Fire Protec tion General Products Catalog Ex tENded Coverage Sp r i n k l e r s Extended Coverage Sprinklers 11 Au to mat i c S p r i n k l e r s extended coverage Sprinklers EC-25 Upright • All hazard K Factor K=25.2 (362,9) • Solder type Thread Size 1" NPT or ISO 7-R1 • Extended coverage area/density Sprinkler Finish Natural Brass • Deflector design allows maximum coverage area of 14' X 14' (4,3m X 4,3m) SIN TY9128 Tech Data TFP213 • For use in high density applications such as “big box” retailing, extra hazard, and high-piled storage occupancies • Minimum operating pressure of 7 psi (0,48 bar) ec - 1 7 Pendent & Recessed Pendent • Solder type K Factor K=16.8 (241,9) • Extended coverage for higher density applications Thread Size ⁄4" NPT • Recessed configuration is ideal for retail applications Polyester, Chrome Plated SIN TY7228 Tech Data TFP215 • Maximum 196 sq. ft./sprinkler spacing (14 ft. x 14 ft. spacing) 3 Sprinkler Finish Natural Brass, White e x t e n d e d co v e r ag e Sp r i n k l e r s • Can reduce the number of installed sprinklers by nearly 50% • Hydraulic calculations based on actual spacing (sxl rule) • Intended for area/density applications of 0.25 gpm/sq. ft. and higher EC-11 & EC-14 Upright, Pendent & Recessed Pendent • Light hazard/Ordinary hazard K Factor K=11.2 (161,3), K=14.0 (201,6) • 3 mm bulb 3 • Nominal K=11.2 designed for coverage applications of 14' x 14' (4,3 m x 4,3 m) up to 20' x 20' (6,1 m x 6,1 m) Thread Size ⁄4" NPT • Nominal K=14.0 designed for coverage applications of 16' x 16' (4,9 m x 4,9 m) up to 20' x 20' (6,1 m x 6,1 m) Escutcheon finish White Coated, Chrome • Low profile glass bulb spray sprinklers Escutcheon Style 30 • Style 40 • Style 60 Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester, Lead Coated SIN TY5137, TY5237, TY6137, TY6237 Tech Data TFP220 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 12 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s extended coverage Sprinklers EC-8 Pendent & Recessed Pendent • Light hazard K Factor K=8.0 (115,2) • 3 mm bulb Thread Size ⁄4" NPT • Covers areas as large as 20' x 20' (6,1 m x 6,1 m) Escutcheon Style 30 • Style 40 3 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY4232 Tech Data TFP223 ec - 5 Pendent & Recessed Pendent • Light hazard K Factor K=5.6 (80,6) • 3 mm bulb Thread Size ⁄2" NPT • Coverage up to 20' x 20' (6,1 m x 6,1 m) Escutcheon 1 Style 50 Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY3232 Tech Data TFP228 Horizontal Sidewall & Recessed Horizontal Sidewall • Light hazard K Factor K=5.6 (80,6) • 3 mm bulb Thread Size ⁄2" NPT • Coverage up to 16' x 24' (4,9 m x 7,3 m) Escutcheon 1 Style 50 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY3302 Tech Data TFP298 e x t e n d e d co v e r ag e Sp r i n k l e r s Escutcheon finish White Coated, Chrome Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 13 Au to mat i c S p r i n k l e r s extended coverage Sprinklers T Y-FRB Horizontal & Recessed Horizontal Sidewall • Light hazard • 3 mm bulb • Two-piece escutcheon converts sidewall sprinklers into low profile sprinkler assemblies with coverage areas up to 16' x 22' (4,9 m x 6,7 m) for K=5.6 and 16' x 24' (4,9 m x 7,3 m) for K=8.0 • Provides 3⁄4" NPT (19,1 mm) of horizontal adjustment from the flush sidewall position K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 Thread Size ⁄2" NPT • 3 ⁄4" NPT Escutcheon Style 10 • Style 20 Style 30 • Style 40 Escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, White Polyester, Chrome Plated SIN TY3332, TY4332 Tech Data TFP296 E LO S W - 2 0 / S W - 2 4 Horizontal Sidewall • Ordinary hazard K Factor K=11.2 (161,3) • 3 mm bulb Thread Size ⁄4" NPT • Utilizes an Extra Large Orifice (ELO) that allows low water pressure requirements, while providing the flow required for extended coverage Sprinkler Finish Natural Brass, Chrome e x t e n d e d co v e r ag e Sp r i n k l e r s • SW-20 Listed to a 16'-0" (4,9 m) wide and a 20'-0" (6,1 m) throw maximum coverage area 3 Plated, White Polyester SIN TY5332, TY5337 Tech Data TFP230 • SW-24 Listed to a 16'-0" (4,9 m) wide and a 24'-0" (7,3 m) throw maximum coverage area T Y-FRL Horizontal Sidewall • Light hazard K Factor K=5.6 (80,6) •K=8.0 (115,2) • Solder type Thread Size ⁄2" NPT • • K=5.6 for QR-EC coverage areas up to 16' x 20' (4,9 m x 6,1 m) and 18' x 16' (5,5 m x 4,9 m) Sprinkler Finish Natural Brass, Chrome • K=8.0 for EC and QR-EC coverage areas up to 16' x 24' (4,9 m x 7,3 m) Tech Data TFP280 1 3 ⁄4" NPT Plated SIN TY3322, TY4322 • QR-EC coverage areas up to 20' x 16' (6,1 m x 4,9 m) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 14 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s extended coverage Sprinklers CHEC Concealed Horizontal Extended Coverage Sidewall • Light hazard K Factor K=8.0 (115,2) • 3 mm bulb Thread Size ⁄4" NPT • Attractive concealed contour Sprinkler Finish Bright White, Chrome 3 • Coverage up to 16' x 22' (4,9 m x 6,7 m) • Lowest flows & pressures allowed by NFPA 13 Plated, Custom SIN TY4332 Tech Data TFP265 • 1⁄2" adjustment • Push on / thread off option • 12" maximum deflector distance from ceiling • No “Slots” in cover plate E LO C Concealed Pendent • Light hazard K Factor K=11.2 (161,3) • Covers 400 sq. ft. (37,2 m ) using less pressure than a standard 1⁄2" (12,7 mm) sprinkler at 225 sq. ft. (20,3 mm) • Available with optional dust and air seal • Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration 3 Thread Size ⁄4" NPT Sprinkler Finish Cover Plate: Chrome Plated, Brushed Chrome Plated, Brass Plated, Bright Brass, White Painted, Bright White, Off White, Custom SIN TY5522 Tech Data TFP250 RFII (Royal Flush II) Concealed Pendent • Light hazard K Factor K=5.6 (80.6) • 3 mm bulb Thread Size ⁄2" NPT • Maximum 18' x 18' (5,5 m x 5,5 m) QR Listing Sprinkler Finish Cover Plate: • Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration • Separable, two-piece design of the mounting cup and cover allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling 1 Chrome Plated, Brass Plated, White Painted, Custom SIN TY3532 Tech Data TFP260 • Internally threaded closure with 1⁄2" (12,7 mm) of adjustment e x t e n d e d co v e r ag e Sp r i n k l e r s 2 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 15 Storage Sprinklers Storage Sprinklers are intended for use in specific applications, including the protection of high-piled and rack storage of a variety of finished goods. These sprinklers can provide more water at lower pressures or more water over a greater area of coverage. In many instances, use of the storage sprinklers can eliminate the need for additional in-rack sprinklers. Intermediate level (in-rack) sprinklers are designed for use in rack storage sprinkler systems, where their thermally sensitive elements must be shielded from the water spray of higher elevation sprinklers that could operate during a fire. Intermediate Level Sprinklers are also used in applications T yco Fire & Building Products • High-Piled Storage • Warehouse • In-Rack Storage • High Challenge Occupancies such as beneath open gridded catwalks. These sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., FM approval and UL Listing is based on NFPA requirements). Fire Protec tion General Products Catalog STORAGE Sprinklers a p p l icatio n s : 17 Au to mat i c S p r i n k l e r s storage Sprinklers ESFR-25™ Pendent • Early Suppression, Fast Response (ESFR) K Factor K=25.2 (362,9) • Solder type Thread Size 1" NPT or ISO 7-R1 • Designed for the protection of rack storage Sprinkler Finish Natural Brass • Eliminates many of the requirements for in-rack sprinklers SIN TY9226 • Materials may be stored up to 40' (12,2 m) high, in buildings up to 45' (13,7 m) • Direct attack on burning fuel by improved heavy sprinkler discharge • Patented frame design substantially reduces the frame shadow effects that often produce non-uniformity in spray pattern Tech Data TFP312 • Novel orifice seal and unique fast response link design are the very latest in sprinkler technology ESFR-17 Pendent • Early Suppression, Fast Response (ESFR) K Factor K=16.8 (241,9) • Solder type Thread Size ⁄4" NPT • Primarily designed for use in ceiling only sprinkler systems Sprinkler Finish Natural Brass • Use of this sprinkler is especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting rack storage arrangements 3 SIN TY7226 Tech Data TFP315 • Operates at lower pressure than ESFR-1 Sto r ag e Sp r i n k l e r s Upright • Early Suppression, Fast Response (ESFR) K Factor K=16.8 (241,9) • Solder type Thread Size ⁄4" NPT • Primarily designed for use in ceiling only sprinkler systems Sprinkler Finish Natural Brass • Use of this sprinkler is especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting rack storage arrangements 3 SIN TY7126 Tech Data TFP316 • Unique, upright design and large K Factor overcome many pendent obstruction problems Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 18 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s storage Sprinklers ESFR-1 Pendent • Early Suppression, Fast Response (ESFR) K Factor K=14.0 (201,6) • Solder type Thread Size ⁄4" NPT • Designed for the protection of rack storage Sprinkler Finish Natural Brass • Eliminates many of the requirements for in-rack sprinklers SIN TY6226 • Direct attack on burning fuel by improved heavy sprinkler discharge 3 Tech Data TFP318 • Patented frame design substantially reduces the frame shadow effects that often produce non-uniformity in spray pattern u ltr a k - 1 7 Upright, Specific Application Control Mode • 5 mm bulb K Factor K=16.8 (241,9) • Control mode sprinkler Thread Size ⁄4" NPT • 155°F/68°C & 200°F/93°C Sprinkler Finish Natural Brass • Full-scale fire testing has shown that the Ultra K17 can control fires with commodities up to Group A plastics, and eliminate the need for in-rack sprinklers SIN TY7153 • Reduced end head pressures often eliminate the need for a fire pump 3 Tech Data TFP330 • Approved for storage heights of 25' (7,6 m) and building heights to 30' (9,1 m) Upright, Specific Application Control Mode, 286° F • 5 mm bulb K Factor K=16.8 (241,9) • Control mode sprinkler Thread Size ⁄4" NPT • 286°F/141°C Sprinkler Finish Natural Brass 3 Sto r ag e Sp r i n k l e r s Tech Data Contact TFBP for details K17-231 Pendent & Upright • 5 mm bulb K Factor K=16.8 (241,9) • Very large orifice sprinkler for use in high challenge storage occupancies Thread Size ⁄4" NPT • Low-pressure requirement can save cost by reducing branch line size, taking advantage of maximized spacing, and upgrading existing densities 3 Sprinkler Finish Natural Brass SIN TY7151, TY7251 Tech Data TFP332 • Can operate at pressures as low as 7 psi (0,48 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 19 Au to mat i c S p r i n k l e r s storage Sprinklers E LO - 2 3 1 B Pendent & Upright • 5 mm bulb K Factor K=11.2 (161,3) • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing Thread Size ⁄2" NPT • • Designed to control high challenge fires with relatively low required pressures 1 3 ⁄4" NPT Sprinkler Finish Natural Brass, Chrome Plated, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY5151, TY5251, TY5851 Tech Data TFP342 E LO - 2 3 1 F R B Pendent & Upright • 3 mm bulb K Factor K=11.2 (161,3) • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing Thread Size ⁄4" NPT • Designed to control high challenge fires with relatively low required pressures SIN TY5131, TY5231 3 Sprinkler Finish Natural Brass, Chrome Plated Tech Data TFP344 E LO - 2 3 1 Pendent & Upright • Solder type K Factor K=11.2 (161,3) • Extra large orifice sprinklers proven for storage occupancies through full-scale fire testing Thread Size ⁄2" NPT • Sto r ag e Sp r i n k l e r s • Designed to control high challenge fires with relatively low required pressures 1 3 ⁄4" NPT Sprinkler Finish Natural Brass, Chrome Plated, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY5111, TY5211, TY5811 Tech Data TFP340 ld "Large Drop" Upright • 5 mm bulb K Factor K=11.2 (161,3) • Control mode sprinkler Thread Size ⁄4" NPT • Designed for the protection of high-piled storage Sprinkler Finish Natural Brass • Can provide a higher level of protection than standard spray sprinklers 3 SIN TY5153 Tech Data TFP335 • Can provide an advantage by eliminating in-rack sprinklers Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 20 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s storage Sprinklers T Y-b Pendent & Upright, Intermediate Level • 5 mm bulb • Intermediate level (in-rack) with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards are not required K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 3 Thread Size ⁄2" NPT • ⁄4" NPT Sprinkler Finish Natural Brass, Lead Coated, Wax Coated, Wax over Lead Coated SIN TY3153, TY3251, TY4153, TY4251 Tech Data TFP351 ty - frb Pendent & Upright, Intermediate Level • 3 mm bulb • Intermediate level with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards are not required K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 3 Thread Size ⁄2" NPT • ⁄4" NPT Sprinkler Finish Natural Brass, Lead Coated SIN TY3133, TY3231, TY4133, TY4231 Tech Data TFP356 ty - l Pendent & Upright, Intermediate Level • Intermediate level with shield • Factory assembled unit having an integral water shield • Used where sprinkler guards are not required K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 3 Thread Size ⁄2" NPT • ⁄4" NPT Sprinkler Finish Natural Brass SIN TY3113, TY3211, TY4113, TY4211 Tech Data TFP350 ty - fr l Pendent & Upright, Intermediate Level • Solder type • Intermediate level with shield • Factory assembled unit having an integral water shield. • Used where sprinkler guards are not required K Factor K=5.6 (80,6) • K=8.0 (115,2) 1 Thread Size ⁄2" NPT • 3 ⁄4" NPT Sprinkler Finish Natural Brass, Chrome Plated SIN TY3123, TY3221, TY4123, TY4221 Tech Data TFP355 Sto r ag e Sp r i n k l e r s • Solder type Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 21 Au to mat i c S p r i n k l e r s storage Sprinklers s p ri n k l er g u a r d s Model G1 & G4 Sprinkler Guards Model G1/S1 & G4/S3 Guards with Shields • Designed for use with specific types of Series TY-B, TYFRB, TY-L, and TY-FRL Sprinklers that may be located in areas that make them susceptible to mechanical or physical damage Finishes Red Painted, Chrome Tech Data TFP780 • Rugged guard design to minimize possible damage to sprinklers • Shields are for use in storage racks or beneath grated mezzanine, or other areas requiring the sprinklers to be shielded from possible discharge from sprinklers above • Can be used with either 1⁄2" or 3⁄4" NPT sprinklers G4/S3 with Shield G4 G1 S1 Sto r ag e Sp r i n k l e r s Model G2 Sprinkler Guard, Model WS-2 Shield, and Model WSG-2 Sprinkler Guard with Shield • Designed for use with Series ELO-231, ELO-231B, or ELO-231FRB Sprinklers that may be located in areas that make them susceptible to mechanical or physical damage Finishes Red Painted, Chrome Tech Data TFP782 • Rugged guard design to minimize possible damage to sprinklers G2 • Shields are for use in storage racks or beneath grated mezzanine, or other areas requiring the sprinklers to be shielded from possible discharge from sprinklers above • Can be used with either 1⁄2" or 3⁄4" NPT sprinklers WSG-2 with Shield WS-2 Shield Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 22 Fire Protection General Products Catalog Tyco Fire & Building Products Rapid Response™ Sprinklers a p p l icatio n s : • Apartments Rapid Response™ Home Fire Sprinkler Systems • Developed specifically for residential occupancies • The most complete system on the market today from a single manufacturer • Features BlazeMaster® CPVC pipe and fittings, making installation quick, easy, flexible, and affordable • Student Housing • Hotels • Beamed Ceilings • Sloped Ceilings in the industry. Other advantages are listings for beam ceilings and for sloped ceilings to an 8:12 pitch. These unique features avoid obstruction to the sprinkler's discharge pattern without adding additional sprinklers. • Tyco’s exclusive ten-year limited warranty lets you install with confidence • Product line meets all NFPA standards • Components are all UL listed for residential installations Residential Sprinklers offer the optimum design and flow characteristics for all residential applications. With k-factors as low as 4.2, the flow requirements are the lowest T yco Fire & Building Products We can match any Sherwin Williams color for sprinklers with this icon. Fire Protec tion General Products Catalog R apid Response™ Sprinklers • Single Family Homes 23 Au to mat i c S p r i n k l e r s rapid response™ Sprinklers LFII Pendent & Recessed Pendent • 3 mm bulb type K Factor K=4.9 (70,6) • Approved for special applications with beamed ceilings Thread Size ⁄2" NPT • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, wet pipe residential occupancies up to and including four stories in height per NFPA 13R and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 1 Escutcheon Style 20 Sprinkler Finish White Polyester, Chrome Plated, Natural Brass SIN TY2234 Tech Data TFP400 Pendent & Recessed Pendent • 3 mm bulb type K Factor K=3.0 (43,2) • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, in wet pipe residential occupancies up to and including four stories in height per NFPA 13R and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Thread Size ⁄2" NPT 1 Escutcheon Style 20 Sprinkler Finish White Polyester, Chrome Plated, Natural Brass SIN TY1234 Tech Data TFP402 r a p i d r e s p o n s e™ Sp r i n k l e r s Horizontal & Recessed Horizontal Sidewall • 3 mm bulb type K Factor K=4.4 (63,4) • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, wet pipe residential occupancies up to and including four stories in height per NFPA 13R and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Thread Size ⁄2" NPT 1 Escutcheon Style 20 Sprinkler Finish White Polyester, Chrome Plated, Natural Brass SIN TY2334 Tech Data TFP412 Horizontal & Recessed Horizontal Sidewall • 3 mm bulb type K Factor K=4.2 (60,5) • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, wet pipe residential occupancies up to and including four stories in height per NFPA 13R and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Thread Size ⁄2" NPT 1 Escutcheon Style 20 Sprinkler Finish White Polyester, Chrome Plated, Natural Brass SIN TY1334 Tech Data TFP410 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 24 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s rapid response™ Sprinklers LFII Flat Plate Concealed Pendent • Solder type K Factor K=4.9 (70,6) • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, in wet pipe residential occupancies up to and including four stories in height per NFPA 13R, and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Thread Size ⁄2" NPT 1 Sprinkler Finish Cover Plate: Flat White, Bright White, Chrome, Custom SIN TY3596 Tech Data TFP442 • Cover plate conceals sprinkler components above the ceiling Flat Plate Concealed Pendent • Solder type K Factor K=4.2 (60,5) • Can be used for horizontal and sloped ceilings Thread Size ⁄2" NPT • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D and in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R Flat White, Bright White, Chrome, Custom SIN TY2596 Tech Data TFP440 1 Sprinkler Finish Cover Plate: • Cover plate conceals sprinkler components above the ceiling Domed Plate Concealed Pendent • Can be used for horizontal and sloped ceilings • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, in wet pipe residential occupancies up to and including four stories in height per NFPA 13R and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K=4.9 (70,6) 1 Thread Size ⁄2" NPT Escutcheon Style 20 Sprinkler Finish Cover Plate: Flat White, Bright White, Chrome, Custom SIN TY2234 Tech Data TFP450 K Factor • Cover plate conceals sprinkler components above the ceiling Flush Pendent and Horizontal Sidewall • Solder type • Pendent model is approved for special applications with beamed ceilings • Used in wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D, in wet pipe residential occupancies up to and including four stories in height per NFPA 13R, and in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K=4.2 (60,5) 1 Thread Size ⁄2" NPT escutcheon Finish White, Chrome, Black, Antique Brass Sprinkler Finish White, Chrome, Black, Antique Brass SIN TY2284, TY2384 Tech Data TFP420, TFP425 K Factor r a p i d r e s p o n s e™ Sp r i n k l e r s • 3 mm bulb type Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 25 Au to mat i c S p r i n k l e r s rapid response™ Sprinklers l fii • N F PA 1 3 O p ti m i z e d S p ri n k l er s The large orifice 6.9 K, 5.8 K and 5.6 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess of four stories. They are optimized for residential applications where this higher water-flow demand is required, and can meet those requirements with less pressure and smaller pipe sizes. Pendent, Recessed Pendent & Domed Concealed • 3 mm bulb type K Factor K=6.9 (99,4) • Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Thread Size ⁄4" NPT 3 Escutcheon Style 30 Escutcheon finish White, Chrome, Brass Sprinkler Finish Natural Brass, Chrome Plated, White Polyester cover plate Finish Flat White, Bright White, Chrome, Custom SIN TY4234 Tech Data TFP408 Horizontal & Recessed Horizontal Sidewall Sprinklers • 3 mm bulb type K Factor K=5.8 (83,5) • Can be used for horizontal and sloped ceilings Thread Size ⁄2" NPT 1 Escutcheon Style 20 r a p i d r e s p o n s e™ Sp r i n k l e r s Sprinkler Finish White Polyester, Chrome Plated, Natural Brass SIN TY4334 Tech Data TFP417 Horizontal & Recessed Horizontal Sidewall • 3 mm bulb type K Factor K=5.6 (80,6) • Can be used for horizontal and sloped ceilings Thread Size ⁄2" NPT 1 Escutcheon Style 20 Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY3334 Tech Data TFP415 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 26 Fire Protection General Products Catalog Tyco Fire & Building Products Dry Sprinklers Dry Sprinklers have been specifically designed for areas in which the sprinkler may be subjected to freezing conditions. These sprinklers have been developed for use in all standard applications, as well as multiple unique scenarios. TFBP Dry Sprinklers are available in both quick and standard response, and come in a variety of finishes. These features, and the advanced engineering in the development of these sprinklers, offer the industry the most complete line of dry sprinklers available. Most models are listed in lengths up to 4'-0". The extended escutcheon option has up to 3" of adjustment. T yco Fire & Building Products • Unheated Warehouses • Freezing Conditions • Loading Docks • Covered Exterior Platforms Fire Protec tion General Products Catalog Dry Sprinklers a p p l icatio n s : 27 Au to mat i c S p r i n k l e r s dry Sprinklers ds-1 Pendent, Upright & Horizontal Sidewall • Standard coverage K Factor K=5.6 (80,6) • All hazards (light hazards, horizontal sidewall) inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • 5 mm bulb escutcheon finish White Coated, Chrome • Lengths to 48" (1220 mm) • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY3255, TY3155, TY3355 Tech Data TFP500 • Designed for use in applications requiring dry sprinklers, or where building construction or aesthetic considerations make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type Pendent Shown Pendent, Upright & Horizontal Sidewall • Standard coverage K Factor K=5.6 (80,6) • Light hazard/Ordinary hazard • 3 mm bulb inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Lengths to 48" (1220 mm) escutcheon finish White Coated, Chrome • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates • Designed for use in applications requiring dry sprinklers, or where building Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester HSW Shown SIN TY3235, TY3135, TY3335 Tech Data TFP510 construction or aesthetic considerations make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type ds-1 d ry Sp r i n k l e r s Extended Coverage Horizontal Sidewall • EC light hazard K Factor K=5.6 (80,6) • 3 mm bulb inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Lengths up to 48" (1220 mm) • Designed for use in light hazard occupancy applications requiring a dry sprinkler to cover areas up to 16’ x 20’ (4,9 m x 6,1 m) or 18’ x 16’ (5,5 m x 4,9 m) • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates escutcheon finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY3338, TY3358 Tech Data TFP520 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 28 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s dry Sprinklers ds-C Concealed Pendent • Standard coverage K Factor K=5.6 (80,6) • All hazard (standard response) inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Light hazard/ordinary hazard (quick response) • 3 mm and 5 mm bulb • Lengths to 48" (1220 mm) • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained Sprinkler Finish Cover Plate: Chrome Plated, Brass Plated, White Painted, Custom SIN TY3535, TY3555 Tech Data TFP515 • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates ds-ECC Extended Coverage Concealed Pendent • EC light hazard/EC ordinary hazard K Factor K=5.6 (80,6) • 3 mm bulb inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Lengths to 48" (1220 mm) • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates Sprinkler Finish Cover Plate: Chrome Plated, Brass Plated, White Painted, Custom SIN TY3539 Tech Data TFP518 ds-2 • Standard coverage K Factor K=11.2 (161,3) • All hazard (standard response) inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Light hazard/Ordinary hazard (quick response) • 3 mm and 5 mm bulb • Extra large orifice • Lengths to 48" (1220 mm) • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained escutcheon Finish White Coated, Chrome Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY5255, TY5235 Tech Data TFP530 • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates d ry Sp r i n k l e r s Pendent Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 29 Au to mat i c S p r i n k l e r s dry Sprinklers ds-2 Extended Coverage Pendent • EC light hazard/EC ordinary hazard K Factor K=11.2 (161,3) • 3 mm bulb • Extra large orifice inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Lengths to 48" (1220 mm) escutcheon finish White Coated, Chrome • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester SIN TY5238 Tech Data TFP540 ds-3 Extended Coverage Horizontal Sidewall • EC ordinary hazard K Factor K=11.2 (161,3) • 3 mm bulb inlet THREAD 1" NPT (Standard Order) connection ISO 7-R1 • Lengths to 48" (1220 mm) • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained escutcheon finish White Coated, Chrome • Ideal for Exterior Loading Docks and Covered Areas and can eliminate the need for dry or anti-freeze systems SIN TY5339 Plated, Brass Plated Sprinkler Finish Natural Brass, Chrome Plated, White Polyester Tech Data TFP550 • Special assembly provides a seal at the main pipe to prevent water from entering the sprinkler assembly until the sprinkler operates DS B - 2 d ry Sp r i n k l e r s Dry Sprinkler Boot (For Use With TFP Dry Type Sprinklers) • Helps to close the air gap created by the clearance hole through a wall or ceiling through which the dry type sprinkler has penetrated Includes 1 Boot, 2 Strap Ties, and • Intended for use with clearance holes through freezer ceiling structures Tech Data TFP591 1 /3 oz. of Adhesive (quantity of adhesive is sufficient for installing 1 Boot) • Helps to stop the air exchange between the inside and outside of the freezer (or any other type of similar construction) to help prevent transfer of moist air into the freezer space • Provides the added feature of eliminating the occurrence of cracking of some commonly used sealants, where the cracking of these sealants subsequently allows the passage of moist air Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 30 Fire Protection General Products Catalog Tyco Fire & Building Products The Tyco® ILLUSION™ 11.2 K-factor sprinkler is designed specifically for Las Vegas' standards. A fast response, extra large orifice concealed pendant sprinkler, the ILLUSION™ is perfect for casino atriums, exhibit halls and retail areas with over 25' ceilings heights; blending in so well they give the illusion they aren't even there. We Cover All The Action a p p l icatio n s : Special Purpose Sprinklers are intended for use in specific applications, including the protection of combustible concealed spaces and areas subject to corrosion. Also, these installations may need consideration for more water at lower pressures, or more water over a greater area. • Attic Spaces • Retail Windows • High Security Institutions • Minimal Water Damage Conditions T yco Fire & Building Products • High Temperature Conditions • Corrosive Conditions Fire Protec tion General Products Catalog Special Purpose Sprinklers SPecial Purpose Sprinklers 31 Au to mat i c S p r i n k l e r s special purpose Sprinklers Attic BB (Back-to-Back), SD (Single Directional), HIP, & AP (Attic Plus) • “Specific Application Sprinklers for Protecting Attics” • 3 mm bulb or solder type • Provides a tested method of protecting an attic Back-To-Back Application • Provides a specific cost advantage by reducing the amount of piping required • Cover attics to 60’-0" wide with a single line of piping, eliminating the need for as many as five branch lines • Saves up to 80% of the piping that would be required with standard sprinklers while providing a higher level of protection Back-To-Back Hip Application K Factor K=4.2 (60,5), K=5.6 (80,60), K=8.0 (115,2) 1 Thread Size ⁄2" NPT 3 ⁄4" NPT Sprinkler Finish Natural Brass SIN TY4180, TY4181, TY4182 TY3180, TY3181, TY3182 TY2180, TY2181, TY2182 TY3183, TY3184, TY3185 TY3187, TY3190, TY2190 Tech Data TFP610 Hip Single Directional Application s p e c i a l p u r p o s e Sp r i n k l e r s BB Spray Patterns HIP Single Directional AREA 2 WITH AP SPRINKLERS AREA 1 WITH BB SPRINKLERS AREA 3 WITH AP SPRINKLERS STAGGERED SPACING WHEN MORE THAN ONE ROW SD AP MINIMUM SEPARATION 15'-0" (4,6 m) Attic Attic Plus Plus (AP) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 32 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s special purpose Sprinklers cc 1 Combustible Concealed Space Sprinklers™,, Upright • 3 mm bulb K Factor K=2.8 (40,3) • Specific application sprinklers Thread Size ⁄2" NPT • Provides protection of light hazard combustible, as well as non-combustible, concealed spaces requiring sprinkler protection Sprinkler Finish Natural Brass 1 SIN TY1189 Tech Data TFP630 • Meets NFPA® Requirements for Specialty Listed Sprinklers in Combustible Concealed Spaces • Allows the use of BlazeMaster® CPVC pipe in combustible concealed areas with the benefit of superior sprinkler protection for Wood truss spaces CC2 Combustible Concealed Space Sprinklers™,, Upright • 3 mm bulb K Factor K=4.2 (60,5) • K=5.6 (80,6) • Specific application sprinklers Thread Size ⁄2" NPT • Provides protection of specific light hazard combustible, as well as non-combustible, concealed spaces requiring sprinkler protection Sprinkler Finish Natural Brass • Allows the use of BlazeMaster® CPVC pipe in combustible concealed areas with the benefit of superior sprinkler protection for Wood truss spaces Combustible Concealed Sprinkler Discharge Pattern SIN TY2189, TY3189 Tech Data TFP632 • Can be used on steel dry pipe sprinkler systems • Increased spacing from 10 ft. (3,1 m) to 12 ft. (3,7 m) • Increased coverage area from 100 ft2 (9,3 m2) to 144 ft2 (13,4 m2) Standard Spray Sprinkler Discharge Pattern s p e c i a l p u r p o s e Sp r i n k l e r s • Meets NFPA® Requirements for Specialty Listed Sprinklers in Combustible Concealed Spaces 1 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 33 Au to mat i c S p r i n k l e r s special purpose Sprinklers WS™ Window Sprinklers, Horizontal & Pendent Vertical Sidewall • 3 mm bulb K Factor K=5.6 (80,6) • Specific application sprinklers Thread Size ⁄2" NPT • Only UL tested sprinklers that can protect glazing in a wall or window and allow it to maintain its mechanical equivalent rating up to two hours Sprinkler Finish White Polyester Coated, • First sprinklers to be UL/C-UL Listed, ICC-ES, and ULC Listed & Approved for maintaining a rated assembly • Pendent allows installation farther away from the glass than the sidewall 1 Chrome Plated, Natural Brass SIN TY3388, TY3488 Tech Data TFP620 • Provides the only UL tested option when seeking wall fire ratings when using tempered or heat strengthened glass • Sidewall permits the window mullion to act as a baffle, allowing the sprinklers to be spaced closely together, if necessary tf p m a x Institutional Pendent • Light hazard/Ordinary hazard K Factor K=5.6 (80,6) • 2.5 mm bulb inlet THREAD ⁄2" NPT connection • Designed to provide maximum solutions to the unique fire protection needs of institutional facilities s p e c i a l p u r p o s e Sp r i n k l e r s • For use in correctional, detention, and mental health care facilities • Vandalizing, moving, or disassembling the sprinkler results in activation and a water flow alarm • Low breakaway weight 1 escutcheon finish Chrome Plated Sprinkler Finish Chrome Plated SIN TY3291 Tech Data TFP652 • Flush mount escutcheons • 175 psi (12,1 bar) Institutional Horizontal Sidewall • Light hazard/Ordinary hazard K Factor K=5.6 (80,6) • 2.5 mm bulb inlet THREAD ⁄2" NPT connection • Designed to provide maximum solutions to the unique fire protection needs of institutional facilities • For use in correctional, detention, and mental health care facilities • Vandalizing, moving, or disassembling the sprinkler results in activation and a water flow alarm 1 escutcheon finish Chrome Plated Sprinkler Finish Chrome Plated SIN TY3391 Tech Data TFP656 • Low breakaway weight • Flush mount escutcheons • 175 psi (12,1 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 34 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s special purpose Sprinklers tf p P h 2 Institutional Pendent • All hazard K Factor K=5.6 (80,6) • Solder type • Low breakaway weight inlet THREAD ⁄2" NPT connection • Flush mount escutcheons escutcheon finish Chrome Plated • 175 psi (12,1 bar) Sprinkler Finish Chrome Plated 1 SIN TY3290 Tech Data TFP650 tf p P h 5 Institutional Horizontal Sidewall • Light hazard/Ordinary hazard K Factor K=5.6 (80,6) • Solder type • Low breakaway weight inlet THREAD ⁄2" NPT connection • Flush mount escutcheons escutcheon finish Chrome Plated • 175 psi (12,1 bar) Sprinkler Finish Chrome Plated 1 SIN TY3390 Tech Data TFP654 I s s u e D Q u a rt z o i d ® High Temperature, Upright & Pendent • Standard coverage K Factor K=5.6 (80,6) • K=8.0 (115,2) • All hazard Thread Size ⁄2" NPT • • 11 mm bulb Sprinkler Finish Natural Brass, Chrome • Extra-high and ultra-high temperature ratings and corrosion resistant coatings SIN TY3191, TY3296, TY4191 , 3 ⁄4" NPT Plated, Lead Coated TY4292 Tech Data TFP690 FTR-1 Fixed Temperature Release • 3 mm bulb K Factor K=5.6 (80,6) • Fixed-temperature, heat detector intended for wet or dry pilot release service Thread Size ⁄2" NPT • Can be used for pilot line service, instead of standard sprinklers, to activate deluge and preaction systems equipped with either wet or dry pilot line detection Polyester Coated, Gray Teflon® Coated SIN TY3030 Tech Data TFP1388 • Corrosion resistant assembly option for outdoor applications (Teflon® coated) 1 Sprinkler Finish Natural Brass, White • Maximum 40 ft. x 40 ft. spacing s p e c i a l p u r p o s e Sp r i n k l e r s • Temperature Ratings to 650°F (343°C) available 1 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 35 Au to mat i c S p r i n k l e r s special purpose Sprinklers T Y - B & T Y - F R B (Alternate Materials Of Construction) Upright & Pendent Sprinklers • TY-B: 5 mm diameter heat sensitive glass bulb, standard response K Factor K=5.6 (80,6) • K=8.0 • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick response Thread Size ⁄2" NPT • • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilized to extend the life of a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres (115,2) 1 3 ⁄4" NPT escutcheon style Style 10 • Style 40 Sprinkler Finish Stainless Steel, SMO, Titanium SIN TY8191, TY8291, TY9191 TY9291, TY8181, TY8281 TY9181, TY9281, TY8192 TY8292, TY8182, TY8282 TY8193, TY8293, TY8183 TY8283 Tech Data TFP680 3mm bulb shown Vertical, Horizontal & Recessed Horizontal Sidewall Sprinklers • TY-B: 5 mm diameter heat sensitive glass bulb, standard response K Factor K=5.6 (80,6) • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick response escutcheon style Style 10 s p e c i a l p u r p o s e Sp r i n k l e r s • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilized to extend the life of a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres 1 Thread Size ⁄2" NPT Sprinkler Finish Stainless Steel, SMO, Titanium SIN TY8391, TY8491, TY8381, TY8481, TY8382, TY8482, TY8393, TY8493, TY8383, TY8483 Tech Data TFP680 3mm bulb shown I LLUS I ON ™ Concealed Standard Coverage Pendent Sprinklers • Extra large orifice/Special hazard K Factor K=11.2 (161,3) • Coverage per NFPA 13 Thread Size • Available with optional dust and air seal • The ILLUSION is concealed in an enclosed escutcheon plate with flat cover for use in those applications where architecturally sensitive areas such as casinos, hotel lobbies, office buildings, churches and restaurants 3 ⁄4" NPT escutcheon style Style 10 • Style 40 Sprinkler Finish Cover Plate: Chrome, Brass, Signal White, Grey White, Pure White, Custom SIN TY5521 Tech Data TFP184 We Cover All The Action Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 36 Fire Protection General Products Catalog Tyco Fire & Building Products a p p l icatio n s : Sprinkler Accessories are for use with the sprinklers and nozzles described in this catalog. Escutcheons are referenced by a style number and are available in brass, chrome or white finish. Please refer to the technical data sheet for additional information and a listing of what finishes are available. T yco Fire & Building Products • Improve Appearance • Onsite Emergency Storage Supply • Conceal Clearance Holes • Protection from Mechanical or Physical Damage Fire Protec tion General Products Catalog Sprinkler Accessories Sprinkler Accessories 37 Au to mat i c S p r i n k l e r s sprinkler accessories E s c u tc h e o n P l ate s Pendent & Sidewall Recessed Escutcheons • Styles 10, 20, 30, 40 & 50 finishes Carbon steel chrome plated, white coated, or brass plated. Series 300 stainless steel white coated or plain unpolished. • Consists of a mounting plate and closure for finished appearance in ceilings or soffits • Maximum 1⁄2" to 3⁄4" NPT adjustment • Intended for use in areas with finished ceilings or walls, and the adjustment provided by these escutcheons reduces the accuracy to which fixed piping to the sprinklers must be cut, while providing a decorative recessed sprinkler installation • Primarily designed for use with standard spray, quick response sprinklers and the (Other colors available on request.) Tech Data TFP770 Designer residential sidewall sprinklers • Available for use with 1⁄2" or 3⁄4" NPT sprinkler heads Style 65, One-Piece Flat Escutcheon Style 401, Two-Piece Adjustable Escutcheon • Used to improve the overall appearance of the sprinkler installation by concealing the clearance holes required for wall or ceiling installation finishes Chrome, White, Brass Tech Data TFP777 • Deep, two-piece, adjustable Style 65 • Available for 1⁄2" and 3⁄4" NPT Style 401 Style 60, Two-Piece Flush Escutcheon s p r i n k l e r acc e s s o r i e s • Used to improve the overall appearance of the sprinkler installation by concealing the clearance holes required for wall or ceiling installation finishes Chrome, White, Brass Tech Data TFP778 • Deep, two-piece, adjustable Style 60 • Available for 3⁄4" NPT S p ri n k l er He a d C a bi n et 3, 6 or 12 Capacity • Provides storage for spare sprinklers and sprinkler wrench Tech Data TFP785 • Spare sprinklers facilitate the prompt replacement of operated or damaged sprinklers and return of fire protection system to service as soon as possible Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 38 Fire Protection General Products Catalog Tyco Fire & Building Products Nozzles & Accessories a p p l icatio n s : • Equipment or Processes that Require Special Designs • Cable Trays • Clean Rooms • Computer Rooms • Gas Turbines • Historic Sites & Museums • Industrial Process Equipment • Machining Centers • Ferries Nozzles & Nozzle Accessories are designed for use in • Conveyors a variety of special hazard applications. Their uses include, but are not limited to, exposure protection, fire control, fire extinguishment, and explosion prevention. Many types of nozzles may be required to provide a properly designed special hazard fire protection system. • Cut-Off Rooms • Engine Test Cells • Flammable Liquid Storage • Food Processing T yco Fire & Building Products • Fuel Storage • Offshore Platforms • Telecom • Transformers • Vapor Suppression Fire Protec tion General Products Catalog Nozzles & Accessories • Flammable Liquid Tanks & Operations 39 Au to mat i c S p r i n k l e r s nozzles and accessories D3 Protectospray® Nozzle • Designed for use in water spray fixed systems for fire protection applications • Open orifice design type for use in deluge systems • Nozzles are external deflector types that discharge a filled cone of water droplets at relatively low velocity • Spray angles available: 65°, 80°, 95°, 110°, 125°, 140°, 160°, and 180° K Factor K =1.2 (17,3) • K=1.8 (25,9) K=2.3 (33,1) • K=3.0 (43,2) K=4.1 (59,0) • K=5.6 (80,6) K=7.2 (108,7) 1 Thread Size ⁄2" NPT Sprinkler Finish Bronze: Natural Finish, Teflon Coated, Lead Coated, Chrome Plated, or Natural Finish Stainless Steel Tech Data TFP802 EA-1 Automatic Protectospray® Nozzle • Bulb type frangible element for use in closed head systems K Factor K=1.4 (20,2), K=2.8 (40,3) • Discharges a filled cone of water droplets at relatively low velocity Thread Size ⁄2" NPT • Spray angles available: 65°, 80°, 95°, 110°, 125°, 140°, 160°, and 180° Lead Coated, Chrome Plated, Corrosion proof Wax Coated Tech Data TFP800 K=5.6 (80,6) 1 Sprinkler Finish Bronze: Natural Finish, B-1 N o z z l e s a n d acc e s s o r i e s Foam-Water Sprinkler • Air aspirating foam-water nozzles K Factor K=3.0 (43,2) • Pendent & upright styles Thread Size ⁄2" • Open nozzle for use in NFPA 16 foam sprinkler system Sprinkler Finish Natural Bronze 1 Tech Data TFP840 HV ”High Velocit y” Spray Nozzle • Open, directional spray nozzles K Factor K =1.6 (23,0) • K=1.8 (26,0) • Designed for use in fixed water spray fire protection systems where a high velocity water application is needed, such as the protection of flammable liquids, electrical transformers, circuit breakers, oil-fired boilers and lube oil systems K=2.8 (40,3) • K=4.6 (66,2) K=5.5 (79,2) • K=6.0 (86,4) Thread Size 1" 11⁄4" (only K=6.4) Sprinkler Finish Natural Brass or Stainless Steel Tech Data TFP815 • Available in six different orifice sizes • Produces a solid conical spray pattern • Available in six angle spray patterns Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 40 Fire Protection General Products Catalog Tyco Fire & Building Products Au to mat i c S p r i n k l e r s nozzles and accessories AM 4 A Q UAM I S T ® Open Type • Open, directional mist nozzles K Factor K=0.24 (3,5) • Listed and Approved for the protection of flammable liquid hazards (UL/FM) Thread Size ⁄2" NPT • Approved for protection of gas turbines (FM) • Maximum ceiling height, 26' 3" (8 m) 1 Sprinkler Finish Stainless Steel Tech Data TD1173 • Compartment volume – - UL - 56,500 ft3 (1,600 m3) – FM - 45,203 ft3 (1,280 m3) • Maximum utilization of water for flammable liquid fire protection • Nozzle coverage: maximum 172 ft2 (16 m2) • Nozzle pressure: 185 to 250 psi (12,8 to 17,2 bar) AM 1 0 A Q UAM I S T ® Open Type • Open mist nozzles K Factor K=0.24 (3,5) • Designed for use in water mist protection systems protecting flammable liquids and turbine bearings Thread Size ⁄2" NPT • Minimal water demand, approximately 3.1 GPM/nozzle at 170psi (11,73 LPM at 11,6 bar) 1 Sprinkler Finish Stainless Steel Tech Data TD1174 • Mist represents latest in fire protection technology • For use in “low pressure” mist applications n o z z l e s a n d acc e s s o r i e s • Minimum operating pressure is 170 psi (11,6 bar) AM 2 4 A Q UAM I S T ® Open Type • Listed and Approved for Marine Type Approved by Lloyds, USCG, DNV, American Bureau of Shipping, MCA, Germanischer Lloyd, Bureau Veritas • Intended Applications – IMO Mandated Local Application System for Protection of Class A Machinery Spaces K Factor 4.7 lpm/bar 1/2, 0.33 gpm/psi 0.5 1 Thread Size ⁄2" NPT Sprinkler Finish Brass, Chrome Plated, White Polyester Tech Data TD1172 • Maximum Distance between nozzles (to plane of protection) - Vertical Clearance Nozzle Spacing –1 m to 3.5 m nozzles - 4.0 meter spacing –3.5 m to 5.0 m nozzles - 3.5 meter spacing –5.0 m to 10.0 m nozzles - 3.0 meter spacing • Nozzle pressure: 175-250 psi (12,1 to 17,2 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Products Fire Protec tion General Products Catalog 41 Au to mat i c S p r i n k l e r s nozzles and accessories F 8 2 2 t h r u F 8 3 4 M u l s ifyre ® Directional Spray Nozzles, Open, High Velocity • Two configurations: basic Mulsifyre Nozzle and Mulsifyre Nozzle with Model F880 Dust Cap • Available in six different models provide a wide range of orifice sizes and water distribution characteristics • Air aspirating foam-water nozzles, for use with all types of foam (required for Non-AFFF type foams) K Factor K=2.0(28,8) • K=2.3(33,1) K=2.7(38,9) • K=2.6(37,4) K=4.6(66,2) • K=5.1(73,4) 3 Thread Size ⁄4" Sprinkler Finish Brass Tech Data TFP810 • Designed for use in water spray fixed systems for fire protection applications where a high velocity water application may be required • Pendent & upright designs • Open nozzle for use on deluge systems c o o l i n g T o wer n o z z l e Type 1 and 2 • Intended for use in fire protection systems for cross flow cooling towers with combustible fill sections • Open nozzle design for use in water spray deluge system K Factor K=2.9 (41,76) 3 Thread Size ⁄4" NPT Sprinkler Finish Stainless Steel Tech Data TFP830 • Installed under the distribution basin, they discharge water in a relatively narrow, elongated spray pattern N o z z l e s a n d acc e s s o r i e s • Type 1 has a waterway designed for use in towers with diffusion decks, Type 2 for those without diffusion decks B l o w - Off P l u g s Plugs for Protectospray® Nozzles or Open Sprinklers • Intended for use in applications where protection is required against infestation or accumulation of debris within the orifice of an open Protectospray Nozzle or open sprinkler K Factor K=5.6 (80) • K=8.0 (115) Tech Data TFP890 • Blow-Off Plugs are designed for both indoor or outdoor use Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 42 Fire Protection General Products Catalog Tyco Fire & Building Products a pp l i c a t i o n s : Wet Pipe Sprinkler Systems are designed for use in applications where the temperature is maintained above freezing. In such systems, the entire piping network is fully pressurized so that water is discharged from a sprinkler head immediately after actuation. Alarm check valves or water flow detectors are used to actuate local and remote alarms. Applications include heated warehouses, factories, hospitals, stores, shopping centers and residential settings such as apartment or condominium complexes, and single family residences. T yco Fire & Building Produc ts • Heated Warehouses • Factories • Apartment or Condominium Complexes • Single Family Residences • Hospitals • Stores • Shopping Centers Fire Protec tion General Products Catalog w e t s ys t e m va lv e s & d e v i c e s WEt System VaLVes & Devices 43 s y s t e m va lv e s & D e v i c e s wet system valves & devices AV-1 Alarm Valve w e t s ys t e m va lv e s & d e v i c e s Butterfly Valve to Control Water Supply to System Water Supply AV-1 Alarm Valve • 21⁄2" (DN65) Alarm Valves may be installed vertically • 4", 6", and 8" (DN100, DN150, and DN200) Alarm Valves may be installed vertically or horizontally • Groove x Groove, Flange x Flange, Flange x Groove Alarm Valves are divided seat ring, rubber-faced clapper, check type, water flow alarm valves • For use in wet pipe (automatic sprinkler) fire protection systems • Automatically actuates electrically and/or hydraulically operated alarms when there Tech Data TFP910 is a steady flow equivalent to the discharge rate for one or more sprinklers • Optional Retard Chamber used in installations subject to variable pressure (generally associated with public water supplies) to help prevent false alarms • Available pre-assembled with modular trim to provide a quick and convenient method for trimming valve risers. Contact TFBP for details • Maximum rated working pressure is 300 psi (20,7 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 44 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s wet system valves & devices C V-1FR Riser Check Valve • Sizes 2" (DN50) through 8" (DN200) • Intended for use in a wet type automatic sprinkler system riser • Furnished with grooved ends that are compatible with grooved pipe and couplings • Can be installed with ANSI class 150 or 300 Flanges utilizing flange adapters Tech Data TFP950 • Designed with a removable cover for ease of field maintenance • Standard seal is grade “E" EPDM • Maximum rated working pressure is 300 psi (20,7 bar) RSV-1 Residential Domestic Shutoff Valve • During the design of a residential sprinkler system, domestic water use should be taken into consideration unless the domestic supply can be stopped when a sprinkler operates • When a sprinkler operates, water supply is automatically diverted from the domestic system to the sprinkler system Tech Data TFP980 • Valve automatically resets after the fire protection system is returned to normal service • Maximum rated working pressure is 175 psi (12,1 bar) • Eliminates the need for pumps, pressurized storage tanks, or electrically operated domestic shutoff valves Riser Manifolds 513D (13D), 513D/R (13D/R) and 513 (13) • 513D (13D) and 513D/R (13D/R): – Available sizes: 1", 1-1/2", and 2" (DN25, DN40, and DN50) – Provides the necessary water flow alarm, pressure gauge, and drain equipment in a single assembly for use in NFPA 13D or 13R residential sprinkler systems • 513 (13): – Available sizes: 1-1/2" thru 6" (DN40 thru DN150) Tech Data TFP960 & TFP962 • Available in different configurations and variety of sizes allowing a cost effective and easy transition to check valves, control valves, and system piping • May be installed either horizontally (flow switch on top) or vertically (flow going up) • Maximum rated working pressure is 175 psi (12,1 bar) – Provides the necessary water flow alarm, pressure gauge, alarm test orifice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems w e t s ys t e m va lv e s & d e v i c e s • 1" (DN25) size is designed for single family demand (NFPA 13D) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 45 s y s t e m va lv e s & D e v i c e s wet system valves & devices Resi-Riser Residential • Sizes 1"- 2" (25-50 mm) Tech Data Contact TFBP for details • Compact, pre-assembled, ready to install sprinkler riser • Brass construction for use in potable water supply • Molded mounting points allow for fast and easy left or right hand installation • Integral test and drain assembly, flow switch with retard mechanism, 300 psi gauge, and check valve • Available with or without pressure relief valve or flow switch retard mechanism features • Compact size allows for easy installation between 2" x 4" (50-100 mm) studs • Maximum rated working pressure is 175 psi (12,1 bar) WMA-1 Water Motor Alarm • Hydraulically operated outdoor alarm for use with appropriate fire protection system valves (alarm, dry, deluge) Tech Data TFP921 • Supplied by dedicated outlet in valve trim line or retard chamber • Can accommodate range of wall thicknesses from 2" to 18" (50 to 450 mm) • Uses energy-efficient lightweight impeller design capable of producing very high sound level • Furnished with approved 3⁄4" (20 mm) Y-strainer for use in alarm line • Corrosion-resistant aluminum alloy gong, gong-mount, and water motor housing • Maximum rated working pressure is 300 psi (20,7 bar) w e t s ys t e m va lv e s & d e v i c e s • Delrin bearings - do not require lubrication - for long life • May be mounted on any type of wall Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 46 Fire Protection General Products Catalog Tyco Fire & Building Products a pp l i c a t i o n s : Dry Pipe Sprinkler Systems are designed for applications where piping and sprinklers are subjected to freezing temperatures, such as unheated warehouses, parking garages, store windows, attic spaces, or loading docks. Valves for the system, however, must be installed in areas not subject to freezing, as this portion of the system does contain water. Pipe lines to the sprinklers are usually pressurized with air, but nitrogen can be used. When pressure in the system is lost by actuation of a sprinkler head, the dry pipe valve trips, activates alarms, and releases water into the system. The system may be equipped with automatic or manual air supply controls and air supervisory devices with appropriate trouble alarms. T yco Fire & Building Produc ts • Unheated Warehouses • Parking Garages • Store Windows • Attic Spaces • Loading Docks, & Other Areas Exposed To Freezing Temperatures Accessory items, such as dry pipe valve accelerators that increase the speed of system operation, and pressure switches used to activate electric alarms, may be used to enhance the system. Fire Protec tion General Products Catalog Dry System Valves & dEvices Dry System VaLVes & Devices 47 s y s t e m va lv e s & D e v i c e s dry system valves & devices Air DPV-1 Dry Pipe Valve d ry s ys t e m va lv e s & d e v i c e s Butterfly Valve to Control Water Supply to System Water Supply DPV-1 Dry Pipe Valve – 21⁄2" thru 6" • Available sizes: 21⁄2" (DN65), 3" (DN80), 4" (DN100) and 6" (DN150) Tech Data TFP1020 • External reset differential dry pipe valves • Rated for use at a maximum service pressure of 250 psi (17.2 bar) • Available as Flange x Flange, Flange x Groove, or Groove x Groove • Listings and Approvals: UL, C-UL, and FM • Unique, offset clapper design minimizes valve size and weight • Used to supply sprinkler installations in which sprinklers are subjected to freezing conditions (40˚F / 4˚C or less) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 48 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s dry system valves & devices ACC-1 Dry Pipe Valve Accelerator • Designed for use with Model DPV-1 dry pipe valves Tech Data TFP1112 • Speeds operation of the dry pipe valve upon loss of air pressure • Rated for use at a maximum water supply pressure of 250 psi (17,2 bar) and a maximum system air (or nitrogen) pressure of 70 psi (4,8 bar) • Automatically adjusts to small or slow changes in system pressure but trips upon a rapid and steady drop in pressure • Designed to trip when system air pressure drops at a rate exceeding approximately 1 psi/minute (0.07 bar/min) • Listings and Approvals: UL, ULC, FM, LPC, SSL, and VdS • Upon tripping, it transmits system air pressure to the intermediate chamber of the dry pipe valve, which neutralizes the differential pressure holding the valve closed and opens the waterway clapper QRS • Maximum working air pressure 70 psi (4,8 bar) Tech Data TFP1100 • Quick opening device intended to reduce the time for dry pipe valve operation following the operation of one or more automatic sprinklers • Operation of the dry pipe valve within four seconds -independent of various combinations of system initial air pressures, system volumes, or sprinkler K Factors • Automatically adjusts to both small and slow changes in system pressure, but trips with a steady drop in pressure (as in the case of sprinkler operation) • Proven electronic release technology as used for electrically operated deluge and preaction systems • Can be used to retro-fit existing mechanical accelerators • Fully assembled package includes switch, solenoid, control panel, and accelerator trim pipe and fittings • Built-in low and high pressure alarm supervision • Battery back-up in the event of primary power failure • Eliminates re-setting problems often incurred with traditional mechanical accelerators • Listings and Approvals: UL, FM d ry s ys t e m va lv e s & d e v i c e s Electronic Accelerator Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 49 s y s t e m va lv e s & D e v i c e s dry system valves & devices AMD-1 Air Maintenance Device, Pressure Reducing Type • Field adjustable Tech Data TFP1221 • Used in systems where compressed air source is available • Used in systems in which the air supply is at a higher pressure than is desired for a sprinkler system or dry pilot line system • Listings and Approvals: UL, ULC, and FM AMD-2 Air Maintenance Device, Compressor (small w/o tank) Control Type • Field adjustable Tech Data TFP1231 • Used in conjunction with a small, non-tank-mounted air compressor • Monitors sprinkler system or dry pilot line detection for deluge system air pressure and automatically cycles the compressor to maintain system pressure within preset limits d ry s ys t e m va lv e s & d e v i c e s • Listings and Approvals: UL, ULC, and FM AMD-3 Nitrogen Maintenance Device, High Pressure (Cylinder) Reducing Type • Field adjustable Tech Data TFP1241 • Used in conjunction with a cylinder of high pressure nitrogen to control the nitrogen pressure in a sprinkler system or a dry pilot line detection for deluge systems • Listings and Approvals: UL, ULC, and FM Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 50 Fire Protection General Products Catalog Tyco Fire & Building Products a pp l i c a t i o n s : Deluge Systems are normally used in special hazard installations where water must be applied to an entire area for protection. They use open sprinklers or spray nozzles attached to a piping system connected to a water supply through the deluge valve. The deluge valve is used to control water flow into deluge, preaction, and special types of fire protection systems in response to a fire. This valve is opened by a fire detection system installed in the same areas. Preaction Systems are used to protect areas where water damage from damaged sprinklers or piping must be avoided. A prealarm of a possible fire allows time for alternate fire extinguishment prior to a sprinkler discharge. They are designed for applications such as refrigerated areas that require maximum protection against inadvertent operation of the sprinkler system. T yco Fire & Building Produc ts • Flammable Liquid Handling Using Water as Extinguishing Agent • Storage Areas for Valuable Artifacts • Computer Rooms • Aircraft Hangars • Archives • High-Hazard Installations • Libraries • Refrigerated Areas Fire Protec tion General Products Catalog Deluge & Preac tion Systems Deluge & Preaction Systems 51 s y s t e m va lv e s & D e v i c e s deluge & preaction systems D e l u g e S y s t e ms Electric Actuation d e lug e & p r e ac t i o n s ys t e m s Deluge fire protection systems are normally used in special hazard installations where an entire area application of water or foam is required for protection. Applications may include flammable liquid handling and storage areas, aircraft hangars, and other high-hazard installations where water is the most effective extinguishing agent. Deluge systems employ open sprinklers or spray nozzles attached to a piping system. The system is connected to a water supply through the deluge valve. This valve is opened by the operation of a fire detection system installed in the same areas as the open sprinklers or nozzles. Deluge systems may be activated by wet or dry pilot sprinklers, or electric detectors. When the deluge valve opens, water flows into the piping system and discharges from all open sprinklers and nozzles. Legend: 1 Deluge Valve (DV-5) 2 Isolation Valve 3 Diaphragm Supply Valve 4 Manual Control Station 5 Automatic Shut-off Valve 6 Automatic Drain Valve 7 8 9 10 11 12 Pressure Switch Water Motor Gong Releasing Panel Spray Nozzle Smoke/Heat Detector Solenoid Valve Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 52 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s deluge & preaction systems S i n g l e I n t e r l o c k P r e ac t i o n S y s t e ms Electric/Electric Actuation Single interlock preaction systems employ automatic sprinklers attached to a piping system containing 10 psi (0,7 bar) supervisory pressure, with a supplemental electric fire detection system installed in the same area as the sprinklers. Preaction systems with 10 psi (0,7 bar) supervisory pressure may also be activated by either wet or dry pilot sprinklers instead of electric detectors. Actuation of the fire detection system from a fire opens the deluge valve, allowing water to flow into the sprinkler piping system and to be discharged only from those sprinklers that have been operated by heat over the fire. Loss of supervisory pressure from the system piping as a result of damaged sprinklers or broken piping will activate a trouble alarm to indicate impairment of the system. The deluge valve will not open due to loss of supervisory pressure. Legend: 1 Deluge Valve (DV-5) 2 Isolation Valve 3 Diaphragm Supply Valve 4 Manual Control Station 5 Automatic Shut-off Valve 6 Automatic Drain Valve 7 Pressure Switch Water 8 Water Motor Gong 9 10 11 12 13 14 15 Releasing Panel Sprinkler Smoke/Heat Detector Solenoid Valve Air Supply Inlet Pressure Switch (Air) Check Valve d e lug e & p r e ac t i o n s ys t e m s Single interlock preaction systems are used to protect areas where there is danger of serious water damage that might result from damaged automatic sprinklers or piping. Typically, such areas include computer rooms, storage areas for valuable artifacts, libraries and archives. Also, preaction systems are effectively used to protect properties where a prealarm of a possible fire condition may allow time for fire extinguishment by alternate suppression means, prior to a sprinkler discharge. In the event the fire cannot otherwise be extinguished, the preaction sprinkler system will then perform as the primary fire protection system. Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 53 s y s t e m va lv e s & D e v i c e s deluge & preaction systems D o u b l e I n t e r l o c k P r e ac t i o n S y s t e ms Pneumatic/Electric Actuation Double interlock preaction systems are designed for applications such as refrigerated areas that require the maximum degree of protection against an inadvertent operation that could result in unnecessary flooding of the sprinkler system piping. d e lug e & p r e ac t i o n s ys t e m s The double interlock system consists of a deluge valve and swing check valve with releasing trim featuring both a solenoid valve and a dry pilot actuator in a series configuration. The swing check valve isolates the body of the deluge valve from the system air or nitrogen pressure that holds the dry pilot actuator closed. The solenoid valve remains closed until it is electrically energized by a deluge releasing panel that responds to the operation of a fire detection device. In order to actuate the double interlock preaction system, two independent events, caused by a fire condition, must occur. The sprinkler system piping must lose air or nitrogen pressure due to the operation of one or more sprinklers, and the deluge releasing panel must energize and open the solenoid valve upon the operation of a fire detection device. The double interlock system will operate only when both the dry pilot actuator and the solenoid valve are open at the same time. Opening of the dry pilot actuator only (for example: a forklift truck accidentally dislodges a sprinkler) or of the solenoid valve only (for example: accidental operation of an electric manual pull station) will cause an alarm, and will not trip the system or flood the sprinkler system piping. Legend: 1 Deluge Valve (DV-5) 2 Isolation Valve 3 Diaphragm Supply Valve 4 Manual Control Station 5 FSV (Fail-Safe Valve) 6 Automatic Drain Valve 7 Pressure Switch Water 8 Water Motor Gong 9 10 11 12 13 14 15 16 Releasing Panel Sprinkler Smoke/Heat Detector Pneumatic Actuator Air Supply Inlet Pressure Switch (Air) Check Valve Solenoid Valve Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 54 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s deluge & preaction systems DV-5 Deluge Valve, External Resetting Diaphragm Style – 11/2" thru 8" Model DV-5 Deluge Valves are diaphragm type valves designed for vertical or horizontal installation for fire protection system service. They are used as “automatic water control valves" in deluge, preaction, and special types of fire protection systems such as foam-water systems. When properly trimmed, the DV-5 Valves provide actuation of fire alarms upon system operation. The unique diaphragm style design of the DV-5 Valve allows external resetting. Deluge or preaction systems can be reset without having to open a valve handhole cover and manually reposition a clapper or latch mechanism. Simply repressurizing the diaphragm chamber resets the valve. The one-piece, diaphragm style design of the DV-5 allows standard internal and external coating of the valve to provide corrosion resistance. The internal corrosion resistance offered by the Rilsan coating makes the DV-5 suitable for most seawater and brackish water supplies when utilized in deluge systems. The external corrosion resistance of the Rilsan coating permits the use of the DV-5 in corrosive atmospheres associated with many types of industrial processing plants and outdoor installations. d e lug e & p r e ac t i o n s ys t e m s • Available sizes: 11⁄2" (DN40), 2" (DN50), 3" (DN80), 4" (DN100), 6" (DN150), and 8" (DN200) • Vertical or horizontal installation • One internal working part • No linkage or clapper assembly • Light weight ductile iron body • Available with deluge and single & double interlock preaction trim • Internally & externally coated • Features external resetting • Diaphragm operation • For most seawater & brackish water supplies • For deluge, preaction & foam systems • Available as Flange x Flange, Flange x Groove, or Groove x Groove body styles • Rated for 250 psi service • Listings and Approvals: UL, C-UL, FM, VdS Tech Data TFP1305 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 55 s y s t e m va lv e s & D e v i c e s deluge & preaction systems R ED - E - C a b i n e t ® Integrated Fire Protection Packages The Red-E-Cabinet is a pre-assembled fire protection valve package enclosed within a free-standing cabinet designed to occupy minimal floor space and to provide an aesthetically pleasing enclosure for a fire protection valve riser. The entire package is pre-wired and the water inlet and outlets to the valve riser are grooved to ease installation. The valve package includes the system (manual) shut-off control valve, automatic water control valve, as well as water flow and supervisory switches where system air pressure is required for either supervision or automatic water control valve actuation. An air compressor and associated controls are also provided. Integral to the Red-E-Cabinet door is a control panel and back-up batteries for providing electrical alarm, supervisory, and trouble functions. All switches within the cabinet are pre-wired to the control panel, making the electrical connections for power, detection circuits, and alarms the only remaining electrical connections to complete the system. d e lug e & p r e ac t i o n s ys t e m s In addition to the integral control panel, windows have been provided in the Red-E-Cabinet door for viewing the releasing panel functions and essential system pressure gauges. A lock for the control panel access door is standard, and a lock for the cabinet door is optional. • The Red-E-Cabinet has been designed to readily incorporate 11⁄2" (DN40), 2" (DN50), 3" (DN80), 4" (DN100) & 6" (DN200) valve risers for the following types of systems: - Deluge System – Electric Actuation - Single Interlock Preaction System - Double Interlock Preaction System • Aesthetically pleasing appearance • Professionally assembled • Minimal installation time • Internally pre-wired • UL/ULC/FM components • Custom manufactured • Model DV-5 deluge valve (standard) • All gauges and panel display are visible externally • UL, C-UL Listed, FM Approved • The Red-E-Cabinet is constructed of 14 gauge steel, and is free-standing. The standard paint finish is bright red Tech Data TFP1300 All Four Side Panels Easily Removed For Ease of Maintenance Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 56 Fire Protection General Products Catalog Tyco Fire & Building Products a pp l i c a t i o n s : General Purpose Valves are for use in fire protection service applications where it is necessary to prevent reverse flow, or where system shut-off or sectional control is desired for closing a fire protection system after operation, or to facilitate testing. T yco Fire & Building Produc ts • Prevention of Reverse Flow • System Shut-Off or Sectional Control • Closure of Fire Protection After Operation • Facilitation of Testing Fire Protec tion General Products Catalog General Purpose Valves General Purpose VaLVes 57 s y s t e m va lv e s & D e v i c e s general purpose valves PRV-1 Pressure Regulating Valve – 2" thru 8" (DN50 thru DN200) • Can be installed either vertically or horizontally Tech Data TFP1580 • Available with threaded, flanged, and cut groove inlet and outlet connections • Grooved connections are suitable for use with grooved pipe couplings that are listed or approved for fire protection service • One piece, one moving part diaphragm Model PRV-1 Pressure Regulating Valve • In-line service (for maintenance) Supply Water under Lower pressure Air - Open to Atmosphere • Rated for use at a maximum pressure of 125 psi (8,6 bar) • Factory outlet “set pressure” of 250 psi (17,2 bar) • Field outlet “set pressure” range of 80 to 150 psi (5,5 to 10,3 bar) To Automatic Sprinklers Supply Water under High pressure • Pilot valve provides for any outlet “set pressure”, i.e., 80 to 150 psi (5,5 to 10,3 bar) Needle Valve Pilot Valve Tamper Cap Regulating Spring Diaphragm Chamber (Factory Set, Do Not Adjust) Inlet Pressure Gauge Outlet Pressure Gauge Waterflow Pressure Alarm Exit Flow Adjusting Screw Locknut To Automatic Sprinklers Waterflow Pressure Alarm Retard Chamber Supply Pressure Gauge Air - Under Pressure PRV-1 DRY PIPE SPRINKLER RISER WET PIPE SPRINKLER RISER Automatic Drain Valve AD-1 Air Supply Pressure Gauge Main Drain Valve (Normally Closed) Main Control Valve (Normally Open) Drain Reset Knob Supply Pressure Gauge Lower Drain Valve (Normally Closed) Main Drain Valve (Normally Closed) Main Control Valve (Normally Open) Outlet Pressure Gauge Sensing Line • Listings and Approvals: UL, & FM MAIN HEADER Water in 200 psi Inlet Cavity Diaphragm Outlet Cavity Water out, reduced pressure 125 psi HOSE STATIONS PRV-1 Water out, reduced pressure 125 psi 0RGHO3593UHVVXUH5HJXODWLQJ9DOYH g e n e r a l pu r p o s e va lv e s 7KLVV\VWHPLVVKRZQLQVWDOOHGDQGUHDG\IRURSHUDWLRQ7KHUHDUHWZR359µVVKRZQLQOLQH WRUHGXFHSUHVVXUH7KHWRSODUJHU359LVXVHGWRUHGXFHSUHVVXUHEHIRUHWKHVSULQNOHUULVHUV7KH VHFRQG359LVXVHGWRUHGXFHZDWHUSUHVVXUHIRU)LUH'HSDUWPHQWFRQQHFWLRQV C V-1F Grooved Check Valve – 2" thru 10" (DN50 thru DN250) • Can be installed either vertically or horizontally Tech Data TFP1550 • Cut groove inlet and outlet connections • Suitable for use with grooved pipe couplings that are listed or approved for fire protection service • Rated for use at a maximum pressure of 300 psi (20,7 bar) • Listings and Approvals: UL, ULC, FM Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 58 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s general purpose valves BFV-N Grooved Butterfly Valve – 21⁄2" thru 10" (DN65 thru DN250) • Indicating type valves provide visual indication of whether the valve is open or closed • Cut groove inlet and outlet connections • Suitable for use with grooved pipe couplings that are listed or approved for fire protection service Tech Data TFP1510 • Rated for use at a maximum pressure of 300 psi (20,7 bar), or 175 psi (12,0 bar) for the 10" model • Listings and Approvals: UL, ULC, FM, Calif. State Fire Marshall Wafer Butterfly Valve – 2" thru 12" (DN50 thru DN300) • Indicating type valves provide visual indication of whether the valve is open or closed • Wafer connections • Suitable for use installation between ANSI Class 125 or 150 flanges without the need for flange gaskets Tech Data TFP1515 • Rated for use at a maximum pressure of 250 psi (17,2 bar) • Listings and Approvals: UL, ULC, FM, Calif. State Fire Marshall Lug Butterfly Valve – 2" thru 12" (DN50 thru DN300)) • Lug connections • Suitable for use installation between ANSI Class 125 or 150 flanges without the need for flange gaskets Tech Data TFP1520 • Rated for use at a maximum pressure of 250 psi (17,2 bar), or for dead end service the maximum pressure is 200 psi (13,8 bar) • Listings and Approvals: UL, ULC, FM, Calif. State Fire Marshall g e n e r a l pu r p o s e va lv e s • Indicating type valves provide visual indication of whether the valve is open or closed Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 59 s y s t e m va lv e s & D e v i c e s general purpose valves Tr i m V a lv e s • Designed for general service such as shut-off, throttling, or drain valves Tech Data Contact TFBP for details • Provide positive shut-off under normal operating conditions B u t t e rf ly V a lv e s “ B u t t e r b a l l" • Bronze body butterfly valves are designed specifically for fire protection applications Tech Data Contact TFBP for details • Models are available in 2" and 21⁄2" NPT • BB-SCS01 has built in tamper resistant SPDT switch for use where proprietary or central station supervision of open position of valve is required • Feature slow closure that substantially minimizes water hammer • May be used as sectional or small system control valves where a distinct visual indication of the valve status is required • Rated for use at a maximum service pressure of 175 psi (12,1 bar) • Listings and Approvals: UL, ULC, and FM DP-1 Dry Pilot Actuator • Dry Pilot Actuator is an auxiliary releasing device g e n e r a l pu r p o s e va lv e s • Designed for Preaction Valves having double interlock electric/pneumatic release Tech Data TFP1380 • Listings and Approvals: UL, ULC, FM, and LPCB • Rated for use at a maximum water supply pressure of 250 psi (17,2 bar) and a maximum system air (or nitrogen) pressure of 50 psi (12,1 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 60 Fire Protection General Products Catalog Tyco Fire & Building Products Specialty Items Specialty Items complement the components used in fire protection systems. These special items help create the ideal configuration for any protection usage. T yco Fire & Building Produc ts • Automatic Quarterly Flow Switch Tests Per NFPA 25 • Automatic Actuation of Electric &/or Hydraulic Alarms • Reduce Accidental Manual Shut-Off & Unnecessary Fire Dept. Dispatch • Eliminate Expelled Water Fire Protec tion General Products Catalog Specialt y Items F e at u r e s : 61 s y s t e m va lv e s & D e v i c e s specialty items DD - 1 ( Dr u m Dr i p ) Wiliag™ Condensate Drain • Ready to install Tech Data Contact TFBP for details • No power machine for repair • No power machine required for cutting pipe and making fittings • Eliminates potential leaks • Eliminates labor of fabrication • Net weight only 6.25 lbs. • Overall length 24" (615 mm) • Turning radius 2.5" (64 mm) • Classic look of a professional job model fl-1 Fusible Links – 50 lb. • Heat-activated releasing device designed for installation in mechanically operated systems requiring a positive acting release mechanism • Used extensively as releasing devices in restaurants and industrial fire protection systems, as well as in heat-activated counterbalanced systems such as fire doors, dampers and kitchen chemical systems • Consists of fusible alloy sealed in the center of a bronze tube by a stainless steel ball Tech Data TFP1610 • When the alloy melts, the fusible assembly compresses, allowing it to eject from between the two-piece strut, strut assembly separates, activating the intended fire protection system or device • Releasing mechanism rated for 5-lbs. to 50-lbs. loads • Listings and Approvals: UL and FM Model A & B-1 sp e c i a lt y i t e m s Pipe Line Strainers • Model A available sizes: – 3" (DN80), 4" (DN100), 6" (DN150), 8" (DN200) and 10" (DN250) Tech Data TFP1640 & TFP1642 • Model B-1 available sizes: – 3" (DN80), 4" (DN100), 6" (DN150), and 8" (DN200) • Compact, lightweight, welded assembly with flanged inlet, outlet and flushing connection • Available sizes: – 6" x 6" (150 mm x 150 mm) – 8" x 8" (200 mm x 200 mm) – 8" with 2 - 6" outlets (200 mm with 2 - 150 mm outlets) – 10" x 8" with 2 - 8" outlets (250 mm with 2 - 200 mm outlets) • Corrosion resistant Type 304 stainless steel screen especially designed for low pressure loss Model B shown • Rated for use in services up to 175 psi (12,1 bar) • Listings and Approvals: UL, C-UL and FM Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 62 Fire Protection General Products Catalog Tyco Fire & Building Products s y s t e m va lv e s & D e v i c e s specialty items Model C Pipe Line Strainer • Available sizes: – 6" x 6" (DN150 x DN150) – 8" x 8" (DN200 x DN200) – 8" (DN200) with 2 - 6" outlets (2 - 150 mm) – 10" (DN250) x 8" (DN200) with 2 - 8" outlets (2 - 200 mm) • Compact lightweight welded hot dipped galvanized assembly with flanged inlet, outlet and flushing connection Tech Data TFP1644 • Corrosion resistant Type 304 stainless steel screen especially designed for low pressure loss • Rated for use in services up to 250 psi (17.2 bar) • Listings and Approvals: UL, C-UL and FM Model MC-1 Manual Control Station • Provides a tamper resistant means for emergency release Tech Data TFP1382 • Interconnection with the valves may be direct via hydraulic (wet) pilot line or indirect via pneumatic (dry) pilot line to a Model DP-1 Dry Pilot Actuator • Listings and Approvals: UL, C-UL and FM • Rated for use in services up to 250 psi (17.2 bar) Signs Identification Signs • Designed to provide information to the end user about the sprinkler system and its components Tech Data TFP1615 sp e c i a lt y i t e m s • Available with a variety of wording combinations to meet the signage requirements of NFPA 13 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 63 s y s t e m va lv e s & D e v i c e s specialty items F i r e D e par t m e n t C o n n e c t i o n s Straight & 90° Fire Department Connections • Designed for fire department use to increase water pressure and volume to automatic sprinkler system or standard-pipe system Tech Data Contact TFBP for details • Available in both 90° side outlet pattern and the straight through siamese pattern H a n g e rs Pipe Hangers • A full-line of pipe hangers for every fire protection need Tech Data Contact TFBP for details • Manufactured to meet the quality standards that the industry demands sp e c i a lt y i t e m s • Meet the requirements of NFPA 13 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 64 Fire Protection General Products Catalog Tyco Fire & Building Products F e at u r e s : Grooved Piping Products are designed for use in fire protection systems and eliminate the need for screwed, welded, or flanged connections. They provide several economic advantages for connecting pipe and fittings when compared to welded or flanged systems. Grooved Piping Products also make field modifications easy, as couplings and fittings can be rotated, added, changed, or eliminated as necessary. Available in a wide range of sizes and configurations. TFBP makes a full line of grooved domestic and import products for fire protection. T yco Fire & Building Produc ts • Easy Field Modifications • Retro-fitting & System Repair • Quickly Joining Steel Pipe without Welding • Dampening Noise & Vibration Transmission • Rigid Connections for Long Runs & Risers Fire Protec tion General Products Catalog Grooved Piping Produc ts Grooved Piping Products 65 65 piping & elec trical devices grooved piping products Figure 772 Rigid Coupling - Patented • Available sizes: 11⁄4" (DN32) through 12" (DN300) Tech Data TFP1850 • Specifically designed to provide rigidity in grooved piping systems • Standard Grade A pre-lubricated gasket • Recommended for dry pipe and freezer applications • Also available with tri-seal Grade "E" gasket for dry pipe fire protection systems, vacuum systems, and freezer applications • Capable of pressures up to 500 psig (3447 kPa) depending on pipe size and wall thickness Figure 577 Rigid Coupling - Patented • Available sizes: 11⁄4" (DN32) through 8" (DN200) Tech Data TFP1854 • Specifically designed to provide rigidity in grooved piping systems • Capable of pressures up to 300 psig (2069 kPa) depending on pipe size and wall thickness • Standard Grade A pre-lubricated gasket Figure 705 Flexible Coupling g r o o v e d p i p i n g p r o du c t s • Available sizes: 11⁄4" (DN32) through 12" (DN300) • Provides the needed flexibility to accommodate differential movement • Capable of pressures up to 300 psig (2068 kPa) depending on pipe size and wall thickness Tech Data TFP1820 • Also available with tri-seal Grade E gasket for dry pipe fire protection systems, vacuum systems, and freezer applications • Standard Grade A pre-lubed gasket Figure 716 Flexible Reducing Coupling • Available sizes: 2" x 11⁄2" (DN50 x DN40) through 8" x 6" (DN200 x DN150) Tech Data TFP1830 • Allows easy transition between two different pipe sizes and replaces two couplings and a reducing fitting • Faster and easier than threading, welding or using flanges Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 66 Fire Protection General Products Catalog Tyco Fire & Building Products piping & elec trical devices grooved piping products Figure 71 Flange Adapter • Available sizes: 2" (DN50) through 12" (DN300) Tech Data TFP1880 • Allows a direct transition from flanged components to a grooved piping system • Bolt patterns conform to ANSI Class 125 and 150 standards Figure 730 Mechanical Tees & Crosses • Threaded or grooved outlet Tech Data TFP1860 • May be used for any tee connection where a threaded or grooved outlet is needed • Can be configured as a cross when necessary g r o o v e d p i p i n g p r o du c t s Gr o o v e d F i t t i n g s Elbows, Tees, Caps & Crosses • Provide an economical and efficient method of changing direction, adding an outlet, reducing or capping grooved piping systems • Cast grooved fittings provide full flow characteristics • Full back stop behind the groove to ensure proper coupling engagement and rigidity • Wide range of grooved fabricated fittings also available Tech Data TFP1810 • Full flow standard end-to-end dimensions • Fully listed and approved for fire protection use • 300 psi pressure rated • 90° elbows and tees are also available in the “short pattern" style Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 67 piping & elec trical devices grooved piping products ADAC AP® • Used to install the last sprinkler on grooved branch line piping or as a drain fitting • Available in 1⁄2", 3⁄4" and 1" outlets • End-of-the-line sprinkler fittings eliminate the need for an end cap and female outlet • Can be turned down for end of line drain Ga lva n i z e d P r o d u c t s • Galvanized grooved piping products are also available g r o o v e d p i p i n g p r o du c t s Tech Data Contact TFBP for details R o l l Gr o o v e rs • Large assortment of roll groovers available • Automatic and portable roll groovers for 1" through 24" pipe Tech Data Contact TFBP for details Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 68 Fire Protection General Products Catalog Tyco Fire & Building Products CPVC Pipe & Fittings TFBP CPVC Pipe & Fittings manufactured with Lubrizol's BlazeMaster® compound are listed by Underwriters Laboratories, Inc. for use in: • Light hazard occupancies as defined in the Standard for Installation of Fire Sprinkler Systems, NFPA 13 • Residential occupancies as defined in the Standard for Installation of Fire Sprinkler Systems in Residential Occupancies to Four Stories in Height, NFPA 13R • Residential occupancies as defined in the Standard for Fire Sprinkler Systems In One and Two Family Dwellings and Manufactured Homes, NFPA 13D • Blazemaster Pipe and Fittings are listed and approved for use in the widest range of applications for any CPVC fire sprinkler systems T yco Fire & Building Produc ts • Light Hazard & Residential Occupancies • Connections to Copper & Steel Piping • Unfinished Basements • Resistance of Sweating, Condensation & MIC • Underground Water Pressure Service • CPVC pipe and fittings • Pipe available in sizes 3⁄4" through 3" in 10' and 15' lengths (Tech Data: IH-1900) • Fittings available in a wide range of designs, in sizes 3⁄4" through 3" • Elbows, tees, crosses, couplings, sprinkler head adapters (SHA’s), reducing tees, reducing bushings, CPVC to grooved couplings Fire Protec tion General Products Catalog CPVC Pipe & Fit tings a pp l i c a t i o n s : 69 piping & elec trical devices cpvc pipe & threaded fittings CPVC Pipe & Fittings • Pipe available in sizes 3⁄4" through 3" in 10’ and 15’ lengths • Manufactured with Lubrizol's BLAZEMASTER® compound • Fittings available in a wide range of designs and sizes 3⁄4" through 3" Tech Data IH-1900 Bac k - t o - Bac k F i t t i n g s • Included in the TFBP line of BLAZEMASTER® CPVC products • Allows two sidewall sprinklers to be piped from one fitting • Ideal when the CPVC piping is located in a 31⁄2" (2" x 4") vertical wall, eliminating the need for extra nipples, fittings and sprinkler head adapters typically associated with supplying two rooms with the same pipe Tech Data IH-1900 • Specially designed and dimensioned to enable the sidewall sprinklers to be recessed with 1⁄2" or 5⁄8" sheet-rock wall covering C P V C t o C o pp e r F i t t i n g c pv c p i p e & t h r e a d e d f i t t i n gs • Available sizes: 3⁄4" through 2" Tech Data IH-1900 • Transition to BLAZEMASTER pipe from traditional copper tube for plumbing services • Transition to steel or BLAZEMASTER CPVC Fire Sprinkler System piping from traditional copper tube for plumbing services is fast, easy, and readily available in the most complete fire sprinkler package in the industry C P V C H a n g e rs & S u pp l i e s • “No Block Hanger" is a two hole strap that eliminates blocking to the beam when hanging CPVC pipe • Positions the face of the pipe 11⁄2" off the face of the joist • Headset hanger is designed to hang CPVC pipe and for the proper placement of the sprinkler before the ceiling is installed Tech Data IH-1900 • One-Step CPVC Cement specifically formulated for use with BlazeMaster pipe and fittings • Provides vertical restraint, eliminating need for additional hangers • BLAZEMASTER Caulk and Walk® Firestop Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 70 Fire Protection General Products Catalog Tyco Fire & Building Products Electrical Devices • Easier to Install, Set & Maintain than Mechanical Accelerators Electrical Devices (alarm and supervisory) allow sprinkler and other fire protection systems to be interfaced with hydraulic or electronic alarm systems so that upon activation of the system, an electrical or mechanical signal activates an audible or visible alarm or computerized notification device. T yco Fire & Building Produc ts • Operation of the Dry Pipe Valve within Four Seconds • Built-in High & Low Pressure Alarm Supervision • Battery Backup in the Event of Primary Power Failure • Proven Electric Release Technology Fire Protec tion General Products Catalog Elec trical De vices Grooved Piping Produc ts F e at u r e s : 71 piping & elec trical devices electrical devices V S R W at e rf l o w A l arm S w i t ch Flow & Pressure Switch • Available sizes: 2" (DN50) through 8" (DN200) Tech Data Contact TFBP for details • Vane type waterflow switch for use on wet sprinkler systems • Retard delay is an adjustable feature that can be set from 0 to 90 seconds • Actuated with a minimum flow of 10 gallons per minute • Flow condition must exist for the period of time necessary to overcome the selected delay period V S R W at e rf l o w A l arm S w i t ch f o r sma l l p i p e Flow & Pressure Switch • Available pipe sizes: 1" (DN25), 11⁄4" (DN32), 11⁄2" (DN40) or 2" (DN50) Tech Data Contact TFBP for details • Vane type waterflow switch for use on wet sprinkler systems • May also be used as a sectional water flow detector on large systems • Installs directly into a threaded tee M o d e l P S 1 0/ P S 4 0 P r e ss u r e a l arm S w i t ch Flow & Pressure Switch • Designed to detect a pressure increase or decrease in fire sprinkler systems Tech Data Contact TFBP for details • PS40 switches are primarily used to monitor low air pressure conditions in dry systems electrical devices • PS10 switch is appropriate for water flow detection Ba l l V a lv e w i t h S u p e rv i s o r y S w i t ch Ball Valve with Tamper & Alarm Switch • Utilizes a 1⁄2" ball valve in combination with a switch assembly Tech Data Contact TFBP for details • Switch assembly enclosed in a tamper resistant NEMA 4 (water resistant) enclosure Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 72 Fire Protection General Products Catalog Tyco Fire & Building Products piping & elec trical devices electrical devicecs P C V S C o n t r o l V a lv e S u p e rv i s o r y S w i t ch Tamper & Alarm Switch • Weather proof and tamper resistant switch for monitoring the open position of post indicator, butterfly and other types of fire sprinkler/control valves Tech Data Contact TFBP for details S o l e n o i d V a lv e For Releasing Service – 1⁄2" (DN15) • Used in conjunction with an electric releasing panel that is listed or approved (as appropriate) for fire protection releasing service, and where the releasing panel is operated by listed or approved (as appropriate) electric fire detectors Tech Data TFP2180 • Available in a variety of voltages for both normal and hazardous locations OSY-SU Tamper & Alarm Switch • Used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve Tech Data Contact TFBP for details • Mounts conveniently to most OS&Y valves ranging in size from 2" (DN50) to 12" (DN300) • Can be used on some valves as small as 1⁄2" 4410-RC Releasing Panel • Provides the interface between detection system, deluge or single or double interlocked preaction valve, and signaling circuit and devices in electrically actuated fire protection systems Tech Data Contact TFBP for details • Separate supervisory zone provided for electronic supervision of valve position, low pressure, and other critical fire protection functions • Has programming capability • Can be used in single zone, cross zone, sequential or cross/sequential electric deduction systems • Listings and Approvals: UL and FM electrical devices • Circulates single sprinkler flow and allows testing of flow switch without external discharge of water - replaces traditional Inspector's test procedure Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 73 piping & elec trical devices electrical devices Ta n k M o u n t e d A i r C o mpr e ss o r For Dry Pipe Sprinkler Systems • Designed for the same high-performance as base mounted units Tech Data Contact TFBP for details • Compressor is mounted on an air tank to offer further ease of installation and availability • Multiple dry systems may be supplied from a single compressor tank that is a constant source of air • Automatic and safety features are built into the unit, reducing installation costs • This is the recommended air supply method for all dry pipe sprinkler systems Bas e M o u n t e d A i r C o mpr e ss o r For Dry Pipe Sprinkler Systems • Designed for high volume (cubic feet of air per minute) at the moderate pressures required for the system Tech Data Contact TFBP for details • Sized properly, these will fill the system to 40 PSIG of air pressure in approximately 30 minutes as required in NFPA 13 R i s e r M o u n t e d A i r C o mpr e ss o r Fully Automatic • Fully automatic and are designed for easy installation Tech Data Contact TFBP for details • Special mounting kits with U-bolts are available to facilitate riser mounting electrical devices • Sized properly, these compressors will fill a system to 40 PSIG within 30 minutes as required in NFPA 13 Model G16AC812 Automatic Supervisory Air Supply • Supplies and maintains air in single interlock preaction fire protection systems having a nominal supervisory air pressure of 10 psi (0.7 bar) Tech Data TFP1620 • Can be mounted on the floor, on a wall, or to the system riser using optional brackets • Listings and Approvals: UL Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 74 Fire Protection General Products Catalog Tyco Fire & Building Products piping & elec trical devices electrical devicecs DAP Series Dry Air Pac™ General’s DAP Series Dry Air Pac™ is an FM Approved, twin tower regenerative dryer / compressor package. This turnkey system is designed to provide the sprinkler system with moisture free air to a -40°F Dew Point. The air compressor is designed to fill the sprinkler system in accordance with NFPA 13 standards, as well as provide the higher pressure needed to allow the twin tower regenerative dryer to function properly. Prior to entering the regenerative air dryer, an air cooled aftercooler cools the compressor’s hot discharge air to a maximum 100°F. A coalescing prefilter with differential pressure gauge removes oil vapor and other contaminants that can destroy the desiccant in the dryer towers. A combination particulate filter and regulator prevents downstream migration of desiccant dust while regulating air pressure to the sprinkler system. The Dry Air Pac™ is controlled by one integrated control panel complete with flow diagram display, 120 volt control circuit with indicating lights for tower drying, drain valve activation and compressor operation, along with panel mounted hour meter, separate drain valve duration and interval controls, drain valve on/off switch and panel control on/off switch. Four panel-mounted pressure gauges are provided for receiver, outlet and drying tower pressures. Purge set pressure gauge is separately mounted and conveniently located at the purge valve for ease of setting the purge flow. All components are pre-piped, pre-tested, and pre-wired for ease of mechanical and electrical installation on site. Each unit includes a UL Listed, FM Approved Air Maintenance Device. -100°F dew point is achievable - consult factory for details. • Combination after filter and regulator • A separate port is provided for attachment of a dewpoint-monitoring device • A coalescing filter, with integral differential pressure gauge, removes oil and water droplets prior to entry to into the desiccant dryer • Fully integrated control panel • The single stage compressor allows for maximum efficiency. Standard equipment includes intercooler, oil fill/breather, oil sight glass and easily removable drain plug • Compact air cooled after cooler • UL, C-UL Listed, FM Approved • Oversized mufflers • Prefilter with differential pressure • Vibration pads • The Dry Air Pac™ comes fully charged with desiccant so that no on-site desiccant installation is required at startup Tech Data Contact TFBP for details • Separate desiccant fill and drain ports are provided to allow re-charging of the dryer tanks without disassembly of the dryer component piping electrical devices Applications for the Dry Air Pac™ include, but are not limited to Freezer Rooms, Cold Storage Warehouses, Attic Spaces and Parking Garages. Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 75 piping & elec trical devices electrical devices LHD Linear Heat Detection Cable The Linear Heat Detection (LHD) cable is a combination of advanced polymer and digital technologies which can be used on any panel, and can detect heat anywhere along its entire length. At the core of the LHD cable is a twisted pair of extremely low resistance, tri-metallic conductors, sheathed in new advanced thermal polymers. These polymers are chemically engineered to break down at specific fixed temperatures allowing the twisted conductors to make contact and initiate an alarm. The polymer used for the protective outer coating of LHD cable is chemical resistant and UV protected. This allows the LHD cable be used in a wide variety of installations and special hazard applications. Spot Detection Junction Box Alarm/Release Cable Strain Relief Connectors Thermo Cable® Tri-Metallic Core: Steel provides tensile strength Copper Increase conductivity Tin for corrosion resistance Loop Cable Ties or other approved fastener Leader Wires Min. 18 AWG 18,000 ft. Releasing LHD Cable Secured to the Sprinkler Pipe by Cable Ties Every 3 - 5 ft. Advanced Polymer Thermal Reactant Sheathing Maximum 10,000 Feet of LHD Cable Per Zone No Protective Tape Required Sollenoid Valve J-Box or ELR-Box Potter® Electronic Series PFC-4410-RC Releasing Panel DV-5 Deluge/Preaction Valve Chemical and UV Resistant Polymer Outer Covering Cable Strain Relief Connectors Wire O.D. 1⁄8” Linear Heat Detection Cable allows a Quell designed fire sprinkler system to be more efficient by quickly recognizing the fire, and conveying the information back to the fire alarm panel. • Ideal for double interlock preaction detection • Install up to 10,000 linear feet per zone electrical devices • Compatible with any conventional releasing panel listed for fire • Can detect heat anywhere along the entire length of cable • Multiple alarm temperatures can be incorporated in the same zone Ultra K17 Upright Sprinkler Spaced 10 ft. Apart 10 ft. 10 ft. • Easy to add a module • Lower material & installation cost • UL, C-UL Listed, FM Approved TEMPERATURE RANGE 155° F (68°C) (typical temperature) 172° F (78°C), 190° F (88°C) 220° F (105°C) Available Polyproplene, PVC, Nylon Resistance .05 ohms/ft resistance per twisted pair RF Tested Up to 10,000 linear ft. Tech Data Contact TFBP for details Jacket MAterial 3-5 ft. LHD Cable Secured to the Sprinkler Pipe with Guide Wire Every 3-5 ft. 3-5 ft. 3-5 ft. Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 76 Fire Protection General Products Catalog Tyco Fire & Building Products Foam Systems a pp l i c a t i o n s : the balanced pressure proportioning method for flammable liquid fire protection applications. They are designed to accurately control the flow of a foam liquid concentrate into a water stream over a wide range of flow rates and pressures. Two basic types, bladder tanks and pump systems, require the foam concentrate pressure to be balanced with the water pressure at the proportioner which meters the proper amount of foam concentrate into the water stream. The resulting foam solution is piped to discharge devices protecting the hazard area. T yco Fire & Building Produc ts • Refineries • Marine Vessels • Warehouses • Class B Polar Solvent Fuel fires such as Methyl Alcohol, Acetone & Ethyl Alcohol • Loading Racks • Special Class A Foam Concentrates for Use with Municipal and Forest Firefighting Hardware & Apparatus • Aircraft Hangars Fire Protec tion General Products Catalog Foam Systems Foam-Water Systems most commonly use • Class B Hydrocarbon Fuel Fires Such as Crude Oils, Gasoline, Diesel Fuels & Aviation Fuels 77 s p e c i a lt y s y s t e m s foam systems Legend: 1 Deluge Valve (DV-5) 2 Isolation Valve 3 Diaphragm Supply Valve 4 Manual Control Station 5 Automatic Shut-off Valve 6 Automatic Drain Valve 7 Pressure Switch 8 Water Motor Gong 9 Releasing Panel 10 Spray Nozzle 11 Smoke/Heat Detector 12 Solenoid Valve 13 Foam Proportioner 14 Foam Bladder Tank 15 Foam Concentrate 16 Hydraulic Ball Valve b l a d d e r ta n Ks Foam Bladder Tanks • Elastomeric bladder stores foam liquid concentrate discharged by incoming water applying pressure to the bladder • Foam concentrate capacities from 50 to 1500 gal (190 to 5678 L) • Both vertical and horizontal models are available • Red standard system paint or coated with an epoxy “CR” red finish for use in marine or corrosive environments • Internal tank perforated center tube provides improved agent discharge • Standard or pre-piped tanks with proportioner for ease of installation 300 gal (1136 L) Horizontal Tank Shown pr o p o r t i o n e r 2" and 21⁄2" In-Line Proportioner f oa m s ys t e m s • Each proportioner consists of a body, inlet nozzle, and metering orifice, all of which are corrosion-resistant brass • The proportioner body is designed with a female NPT threaded inlet and a male NPT threaded outlet in sizes of 2" or 21⁄2" • The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring) FOAM CONCENTRATE INLET • Clearly marked on the proportioner body are the flow direction arrow, as well as the type and percentage of concentrate for which the proportioner was designed JET RETAINING RING FOAM SOLUTION DISCHARGE • The inlet nozzle is secured by a stainless steel retaining ring THROAT BODY WATER INLET 001185 METERING ORIFICE Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 78 Fire Protection General Products Catalog Tyco Fire & Building Products s p e c i a lt y s y s t e m s foam systems I n - L i n e pr o p o r t i o n e r In-Line Proportioner Pump System • Maintains an equal pressure in the foam concentrate and water inlets to the proportioner. This allows the proportioner to be used over a wide range of flows and pressures. It responds quickly and accurately to changes in the water inlet pressures and flow rates • Spool valve design ensures accurate pressure regulation and rapid response to changes in flow demand • Six standard sizes • Brass foam concentrate piping with stainless steel trim accessories • Standard for use in marine applications and other corrosive environments • Nameplates for valve identification • Choice of unpainted brass or standard red paint finish • Used with an atmospheric foam concentrate tank and a positive displacement foam concentrate pump F o am A g e n t s ANSULITE® 1% AFFF Concentrate • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 1% solution in fresh, salt or hard water. 1% premix in fresh or potable water. UL Listed. ANSULITE® 1% Freeze-Protected AFFF Concentrate • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 1% solution in fresh, salt or hard water. 1% premix in fresh or potable water. Concentrate is freeze protected to –20 °F (–29 °C). UL Listed. ANSULITE® 3% AFFF Concentrate (AFC-3-A) • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels, and aviation fuels. Aspirated or nonaspirated discharge devices. 3% solution in fresh, salt or hard water. 3% premix in fresh or potable water. UL Listed. • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 3% solution in fresh, salt or hard water. 3% premix in fresh or potable water. UL Listed. On QPL under U.S. Military Specification MILF- 24385F. ANSULITE® 3% Freeze-Protected AFFF Concentrate • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 3% solution in fresh, salt or hard water. 3% premix in fresh or potable water. Concentrate is freeze protected to –20 °F (–29 °C). UL Listed. f oa m s ys t e m s ANSULITE® PREMIUM 3% AFFF Concentrate MIL SPEC (AFC-5-A) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 79 s p e c i a lt y s y s t e m s foam systems F o am A g e n t s ( c o n t. ) ANSULITE® 6% AFFF Concentrate (AFC-3) • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 6% solution in fresh, salt or hard water. 6% premix in fresh or potable water. UL Listed. ANSULITE® PREMIUM 6% AFFF Concentrate MIL SPEC (AFC-5) • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated or nonaspirated discharge devices. 6% solution in fresh, salt or hard water. 6% premix in fresh or potable water. UL Listed. On QPL under U.S. Military Specification MILF- 24385F. ANSULITE® 3X3 Low Viscosity Alcohol-Resistant AFFF Concentrate • Superior firefighting performance on Class B fuel fires. Used as 3% concentrate on BOTH hydrocarbon fuels such as gasoline, fuel oil, etc., and polar solvent (water miscible) fuels such as methyl alcohol, acetone, MTBE, etc. Low viscosity formula enhances performance with in-line eductors, balanced pressure systems and built-in systems on firefighting vehicles. Aspirated or nonaspirated discharge devices. 3% solution in fresh, salt or hard water. 3% premix in fresh water. UL Listed, FM and USCG Approved. ANSULITE® ARC Alcohol-Resistant 3%/6% AFFF Concentrate • For use on Class B fuel fires: 3% concentrate on hydrocarbon fuels such as gasoline, fuel oil, etc. and 6% on polar solvent (water miscible) fuels such as methyl alcohol, acetone, MTBE, etc. Aspirated or nonaspirated discharge devices. 3%/6% solution in fresh, salt or hard water. 3%/6% premix in fresh or potable water. UL Listed and FM Approved. ANSULITE® ARC 3 or 6 Freeze Protected f oa m s ys t e m s • Freeze Protected ANSULITE® ARC is intended for use as a 3% or 6% proportioned solution, depending on the type of fuel hazad. Fresh or salt water can be used to create the foam water solution. The foam concentrate may be stored at temperatures down to 0 °F (–18 °C) without freezing. If stored below the minimum use temperature, freezing may occur. If freezing does occur, thaw and remix the concentrate prior to use. 3% Regular Protein Foam Concentrate • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Must be used with air aspirating type discharge devices. 3% solution in fresh, salt or hard water. UL Listed. Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 80 Fire Protection General Products Catalog Tyco Fire & Building Products s p e c i a lt y s y s t e m s foam systems F o am A g e n t s ( c o n t. ) 3% Fluoroprotein Foam Concentrate • For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Must be used with air aspirating type discharge devices. 3% solution in fresh, salt or hard water. UL Listed. SILV-EX® “Class A" Fire Control Concentrate • Makes water at least five times more effective on many Class A deep-seated applications including wild fires and fires found in structures, paper, tires, and coal. Proportioned from 0.1% to 1% in fresh brackish or sea water; as a premix in fresh or potable water for long-term storage. Delivered using aspirating and nonaspirating discharge devices, compressed air foam systems or dropped from fixed or rotary wing aircraft. Approved by U.S. Forest Service. ANSUL-A™ Municipal “Class A" Fire Control Concentrate • ANSUL-A foam concentrate is formulated using fluorine-free surfactants to perform on Class A combustible materials. ANSUL-A is compatible for use in compressed air foam systems (CAFS) over the use range of 0.1% to 1.0%. The minimum storage temperature for this concentrate is 20 °F (–6.7 °C). TARGET-7™ Vapor Mitigation & Neutralizing Agent • For use on highly toxic chemicals like chlorine dioxide and titanium tetrachloride. Mitigates dangerous vapor releases and simultaneously neutralizes (with the addition of an acidic or caustic agent, depending on the application) the spilled material without causing additional vapor release. H i g h - E x pa n s i o n f o am P r o d u c t s JET-X® High-Expansion Foam Generators • No electrical power is required • The generators come in various sizes and are used for both portable and fixed-system applications JET-X® 2 3⁄4% High-Expansion Foam Concentrate • For use on Class A, B and LNG fires. Capable of total flooding large rooms and enclosures when used with JET-X high expansion generators at 200:1 to 1000:1 expansion ratios (2 3⁄4% concentration). Also used with medium-expansion equipment at 50:1 to 200:1 expansion ratios (2% concentration). Used only with air aspirating foam discharge devices. UL Listed and FM Approved. f oa m s ys t e m s • Water-powered. Designed to deliver JET-X® high expansion foam with a maximum output capacity of 24,000 cfm (680 cu. m/min.) The generators are of steel construction with a water powered motor and stainless steel foam screen Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 81 s p e c i a lt y s y s t e m s foam systems A ppr o v e d D i schar g e D e v i c e s f o r u s e w i t h F o am C o n c e n t rat e s Foam liquid concentrates are suitable for use on fires involving ordinary hydrocarbon petroleum products, and some foam liquid concentrates may also be suitable for use on fires involving polar solvent fuels. The fire protection system designer first identifies the fuel load and selects the foam liquid concentrate according to its ability to be used for a given fuel load. Upon selecting the foam liquid concentrate, the designer then selects equipment, including discharge devices, based on listing/approval compatibility of the equipment with the concentrate. Discharge devices fall into one of four categories: • Foam-water sprinklers • Foam-water spray nozzles • Non-aspirating spray nozzles • Standard sprinklers D3 B-1 Protectospray™ Nozzle 1⁄ Tech Data TFP802 Tech Data TFP840 additional info Page 40 2" Foam-Water Sprinkler additional info Page 40 EA-1 TY - B Automatic Protectospray™ Nozzle Upright & Pendent Tech Data TFP800 additional info additional info Tech Data TFP151 Page 8 Page 40 TY - F R B ELO - 231 B Upright & Pendent Pendent & Upright Tech Data TFP171 Tech Data TFP342 additional info Page 8 additional info Page 20 ELO - 2 3 1 F R B ELO - 231 Pendent & Upright Pendent & Upright Tech Data TFP344 Tech Data TFP340 additional info f oa m s ys t e m s Tech Data TFP2005 Page 20 additional info Page 20 TY - F R L Upright & Pendent Tech Data TFP130 additional info Page 10 Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 82 Fire Protection General Products Catalog Tyco Fire & Building Products AQuaMist® Systems a pp l i c a t i o n s : • Cable Trays • Historic Sites & Museums • Clean Rooms • Conveyors • Machining Centers • Cut-Off Rooms • Ferries • Engine Test Cells AQUAMIST® Systems utilize the newest and most unique nozzles developed and approved for fire protection. They offer an alternative to gaseous, foam, and heavy density sprinkler systems. By utilizing a higher pressure than a normal sprinkler system, but a 50-80% lower water flow, the AquaMist Systems use less water more effectively, reduce pipe sizes and labor costs, and minimize cleanup and water damage. T yco Fire & Building Produc ts • Flammable Liquid Storage • Food Processing • Fuel Storage • Offshore Platforms • Telecommunications • Transformers • Vapor Suppression • Gas Turbines Fire Protec tion General Products Catalog AQuaMist® Systems • Industrial Process Equipment • Computer Rooms 83 s p e c i a lt y s y s t e m s aquamist® systems “ M C C " M i s t C o n t r o l C e n t e r w i t h R ED - E C a b i n e t ® Pre-Assembled Fire Pump, Controller, Deluge Valve Cabinet & Releasing Panel The “MCC" Pump Skid Package is the self-contained control center of the AquaMist® System. The compact skid unit has been professionally designed and assembled to ease system installation and to meet the most stringent project requirements. • Power must be provided for the control cabinet and pump controller • Detection circuits must be installed and wired to the control cabinet • An adequate water supply must be piped to the pump supply piping inlet Fire Pump Controller To System PFC4410 Single zone, cross zone, or sequential cross zone releasing panel Required Outlet Strainer The pipe, fittings, hangers and AquaMist nozzles are to be connected to the strainer outlet. DV-5 Deluge Valve Variable Pressure AquaMist Fire Pump How the AquaMist System Works aqua m i s t® s ys t e m s 1 • Evaporation (heat extraction) is a function of surface area of droplets HEAT 2 • Reducing droplet size increases surface area OXYGEN VAPOR • Increase in surface area allows for larger cooling effect for a given flow 3 LARGER DROPS PENETRATE TO BURNING SURFACE • Fire extinguishment is improved with direct contact of water droplets • This type of extinguishment is normally associated with standard sprinklers • Important part of operation if ventilation is a factor and Class A combustibles are present • Water converts to vapor expanding by a factor of 1650 times • Oxygen is displaced and diluted, thereby blocking it from the fuel source • Higher heat level causes a faster vaporization 4 BLOCKS RADIANT HEAT AND COOLS GASSES • Small water droplets tend to remain suspended • The expanding mist will expand and cool the gases and other fuels in the area • Blocks the transfer of radiant heat to the adjacent combustibles and pre-wets them Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 84 Fire Protection General Products Catalog Tyco Fire & Building Products s p e c i a lt y s y s t e m s aquamist® systems AM10 AQUAMIST® Open Type Mist Nozzle • Open spray nozzles K Factor K=0.24 (3,5) • Designed for use in water mist protection systems protecting flammable liquids and turbine bearings Thread Size • Minimal water demand, approximately 3.1 GPM/nozzle at 170 psi (11,73 lpm at 11,6 bar) • Mist represents latest in fire protection technology 1⁄ 2" NPT Finish Stainless Steel tech data TD1174 • Pendent & upright designs • Open nozzle for use on deluge systems • For use in “low pressure" mist applications • Minimum operating pressure is 170 psi (11,6 bar) AM4 AQUAMIST® Open Type Mist Nozzle • Open spray nozzles K Factor K=0.24 (3,5) • Listed and Approved for the protection of flammable liquid hazards (UL/FM) Thread Size • Approved for protection of gas turbines (FM) • Maximum ceiling height, 26' 3" (8 m) 1⁄ 2" NPT Finish Stainless Steel tech data TD1173 • Compartment volume: – UL - 56,500 ft3 (1,600 m3) – FM - 45,203 ft3 (1,280 m3) • Maximum utilization of water for flammable liquid fire protection • Nozzle coverage: maximum 172 ft2 (16 m2) • Nozzle pressure: 185 to 250 psi (12,8 to 17,2 bar) AM24 AQUAMIST® Automatic Type Mist Nozzle • Intended applications – IMO mandated local application system for protection of class a machinery spaces • Maximum distance between nozzles (to plane of protection) - vertical clearance nozzle spacing – 1m to 3.5m nozzles - 13.1' (4,0 m) spacing – 3.5m to 5.0m nozzles - 11.5' (3,5 m) spacing – 5.0 m to 10.0 m nozzles - 9.8' (3,0 m) spacing K Factor 0.33 Gpm/psi 0.5, aqua m i s t® s ys t e m s • Listed and Approved for marine type approved by Lloyds, USCG, DNV, American Bureau of Shipping, MCA, Germanischer Lloyd, Bureau Veritas (4,71 Lpm/bar 1/2) 1⁄ " NPT Thread Size 2 Finish Stainless Steel tech data TD1172 • Nozzle pressure: 175-250 psi (12,07 - 17,24 bar) Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. T yco Fire & Building Produc ts Fire Protec tion General Products Catalog 85 Index 4410-RC . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 DS-ECC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Model C. . . . . . . . . . . . . . . . . . . . . . . . . . . .63 ACC-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 DV-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Model FL-1. . . . . . . . . . . . . . . . . . . . . . . . . 62 ADACAP®. . . . . . . . . . . . . . . . . . . . . . . . . . 68 EA-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 82 Model G16AC812. . . . . . . . . . . . . . . . . . . 74 AM10 AQUAMIST. . . . . . . . . . . . . . . . 41, 85 EC-11 & EC-14. . . . . . . . . . . . . . . . . . . . . . 12 Model MC-1. . . . . . . . . . . . . . . . . . . . . . . . 63 AM24 AQUAMIST. . . . . . . . . . . . . . . . 41, 85 EC-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 AM4 AQUAMIST. . . . . . . . . . . . . . . . . 41, 85 EC-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Model PS10/PS40 Pressure alarm Switch. . . . . . . . . . . . . . . . . . . . . 72 AMD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 EC-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Nozzles & Accessories. . . . . . . . . . . . 39-42 AMD-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 EC-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 OSY-SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 AMD-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Electrical Devices. . . . . . . . . . . . . . . . 71-76 AP “Attic Plus”. . . . . . . . . . . . . . . . . . . . . . 32 ELO SW-20/SW-24. . . . . . . . . . . . . . . . . . 14 PCVS Control Valve Supervisory Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Approved Discharge Devices for use with Foam Concentrates. . . . . . . . . . 82 ELO-231 . . . . . . . . . . . . . . . . . . . . . . . . 20, 82 Aquamist® Systems. . . . . . . . . . . . . . 83-85 ELO-231B. . . . . . . . . . . . . . . . . . . . . . . 20, 82 Attic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ELOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 AV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Escutcheon Plates. . . . . . . . . . . . . . . . . . 38 B-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 82 ESFR-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Back-to-Back Fittings . . . . . . . . . . . . . . . 70 ESFR-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Ball Valve with Supervisory Switch. . . 72 ESFR-25™ . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Base Mounted Air Compressor. . . . . . 74 Extended Coverage Sprinklers . . . 11-15 BB “Back-to-Back”. . . . . . . . . . . . . . . . . . . 32 F822 thru F834 Mulsifyre®. . . . . . . . . . . 42 BFV-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Figure 577 . . . . . . . . . . . . . . . . . . . . . . . . . 66 Bladder Tanks. . . . . . . . . . . . . . . . . . . . . . 78 Figure 705 . . . . . . . . . . . . . . . . . . . . . . . . . 66 Blow-Off Plugs. . . . . . . . . . . . . . . . . . . . . 42 Figure 71. . . . . . . . . . . . . . . . . . . . . . . . . . .67 Butterfly Valves “Butterball”. . . . . . . . . 60 Figure 716 . . . . . . . . . . . . . . . . . . . . . . . . . 66 CC1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Figure 730 . . . . . . . . . . . . . . . . . . . . . . . . . 67 CC2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Figure 772 . . . . . . . . . . . . . . . . . . . . . . . . . 66 CHEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Fire Department Connections. . . . . . . 64 Cooling Tower Nozzle. . . . . . . . . . . . . . . 42 Foam Agents. . . . . . . . . . . . . . . . . . . . 79-81 CPVC Hangers & Supplies. . . . . . . . . . . 70 Foam Systems. . . . . . . . . . . . . . . . . . . 77-82 CPVC Pipe & Fittings. . . . . . . . . . . . . 69-70 FTR-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 CPVC Pipe & Fittings. . . . . . . . . . . . . . . . 70 Galvanized Products. . . . . . . . . . . . . . . . 68 CPVC to Copper Fitting . . . . . . . . . . . . . 70 General Purpose Valves. . . . . . . . . . 57-60 CV-1F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Grooved Fittings . . . . . . . . . . . . . . . . . . . 67 CV-1FR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Grooved Piping Products . . . . . . . . 65-68 D3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 82 Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 DAP Series “Dry Air Pac™”. . . . . . . . . . . 75 High-Expansion Foam Products. . . . . 81 DD-1 (Drum Drip) . . . . . . . . . . . . . . . . . . 62 HIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Deluge & Preaction Systems . . . . . 51-56 HV “High Velocity”. . . . . . . . . . . . . . . . . . 40 Deluge Systems. . . . . . . . . . . . . . . . . . . . 52 ILLUSION™. . . . . . . . . . . . . . . . . . . . . . . . . 36 Double Interlock Preaction Systems. 54 In-Line Proportioner. . . . . . . . . . . . . . . . 79 DP-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Issue D Quartzoid . . . . . . . . . . . . . . . . . . 35 DPV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 K17-231. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Dry Sprinklers. . . . . . . . . . . . . . . . . . . . . . 27 LD “Large Drop”. . . . . . . . . . . . . . . . . . . . 20 Dry Systems Valves & Devices. . . . 47-50 LFII. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25 DS-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 LFII NFPA 13 Optimized Sprinklers. . . 26 DS-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 30 LHD Linear Heat Detection Cable. . . . 76 DS-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 DSB-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 MCC Mist Control Center with RED-ECabinet. . . . . . . . . . . . . . . . . . . . . . . . . . 84 DS-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Model A & B-1. . . . . . . . . . . . . . . . . . . . . . 62 ELO-231 FRB . . . . . . . . . . . . . . . . . . . . 20, 82 Proportioner. . . . . . . . . . . . . . . . . . . . . . . 78 PRV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 QRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Rapid Response™ Sprinklers. . . . . . 23-26 Red-E-Cabinet®. . . . . . . . . . . . . . . . . . . . . 56 Resi-Riser. . . . . . . . . . . . . . . . . . . . . . . . . . 46 RFII (Royal Flush II). . . . . . . . . . . . . . . 9, 15 Riser Manifolds. . . . . . . . . . . . . . . . . . . . . 45 Riser Mounted Air Compressor. . . . . . 74 Roll Groovers. . . . . . . . . . . . . . . . . . . . . . . 68 RSV-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 SD “Single Directional”. . . . . . . . . . . . . . 32 Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Single Interlock Preaction Systems . . 53 Solenoid Valve . . . . . . . . . . . . . . . . . . . . . 73 Special Purpose Sprinklers. . . . . . . 31-36 Specialty Items. . . . . . . . . . . . . . . . . . 61-64 SprinkCAD®. . . . . . . . . . . . . . . . . . . . . . . . 87 Sprinkler Accessories. . . . . . . . . . . . 37-38 Sprinkler Guards . . . . . . . . . . . . . . . . 22, 38 Sprinkler Head Cabinet. . . . . . . . . . . . . 38 Standard Spray Sprinklers. . . . . . . . . 7-10 Tank Mounted Air Compressor. . . . . . 74 TFP MAX. . . . . . . . . . . . . . . . . . . . . . . . . . . 34 TFP PH2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 TFP PH5. . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Trim Valves. . . . . . . . . . . . . . . . . . . . . . . . . 60 TY-B. . . . . . . . . . . . . . . . . . . . . . 8, 21, 36, 82 TY-B & TY-FRB (Alternate Materials of Construction). . . . . . . . . . . . . . . . . .36 TY-FRB. . . . . . . . . . . . . . . 8, 9, 14, 21, 36, 82 TY-FRL. . . . . . . . . . . . . . . . . . . 10, 14, 21, 82 TY-L . . . . . . . . . . . . . . . . . . . . . . . . . . 9, 10, 21 TY-QRF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Ultra K-17. . . . . . . . . . . . . . . . . . . . . . . . . . 19 VSR Waterflow Alarm Switch. . . . . . . . 72 Wet Systems Valves & Devices. . . . 43-46 WMA-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 WS™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 SprinkCAD ® The Next Generation of SprinkCAD Design Software Complete Fire Sprinkler System Design Programs Built Upon the Industry-Leading CAD Graphics Program SprinkCALC ™ Advanced Hydraulic Calculations Welcome to the newest and most advanced hydraulic calculation program available today... SprinkCALC SprinkFDT ™ The first program to be listed by Underwriters Laboratories and Factory Mutual specification tested for the calculation of dry type systems per NFPA® requirements SprinkSLIC ™ Complete Fire Sprinkler Stock Listing The name of the game is "PIPE ON THE JOB" and Stocklisting is the bridge between design and installation SprinkCODE ™ Interactive NFPA 13® Code Selector Whether it's an estimate or the final design, this Code Expert is an essential member of your staff www.sprinkcad.com NORTH AMERICAN & WORLDWIDE HEADQUARTERS Tyco Fire & Building Products 451 N. Cannon Avenue Lansdale, PA 19446 Tel: 215-362-0700, 800-523-6512 Fax: 215-362-5385 LATIN AMERICA Regional Headquarters South America, Central America & Caribbean 1802 S.W. 2nd Street Pompano Beach, FL 33069 Tel: 954-781-0866 Fax: 954-781-9330 EUROPE & MIDDLE EAST AUSTRALIA Regional Headquarters Kopersteden 1, NL-7547 TJ Enschede P.O. Box 198, 7500 AD Enschede, The Netherlands Tel: 31-53-428-4444 Fax: 31-53-428-3377 Regional Headquarters 567 Somerville Road Sunshine, VIC 3020 Tel: 13-00-725-688 Fax: (61) 3-9933-6204 ASIA Regional Headquarters No. 45 Tuas Avenue 9 Singapore 639189 Tel: 65-6861-1655 Fax: 65-6861-1312 www.tyco-fire.com www.tyco-rapidresponse.com www.grinnell.com Europe & Middle East: www.tycobuilding.com Asia: www.tyco-fire.com.cn Australia: www.tycobuilding.com.au TF-2008003 • Copyright ©Tyco Fire & Building Products • Printed in USA • VIS • 25M • 4/08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2008:06:16 14:03:41-04:00 Creator : Adobe InDesign CS2 (4.0.5) Modify Date : 2011:08:08 16:11:35-04:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:1ccf8229-bf40-4e5d-9df2-11bee13be754 Document ID : adobe:docid:indd:b959d247-e842-11dc-b205-df0137de0025 Rendition Class : proof:pdf Derived From Instance ID : b959d246-e842-11dc-b205-df0137de0025 Derived From Document ID : adobe:docid:indd:fc202c6d-e227-11dc-a4a1-bcfedee86a1a Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 762.00, 300.00, 300.00, 72.00, 300.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 334.33, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 762.00, 300.00, 300.00, 72.00, 300.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 762.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 334.33, 300.00, 300.00, 300.00, 72.00, 72.00, 300.00, 300.00, 72.00, 72.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00, 762.00, 762.00, 762.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:4CA76D7AE7EE11DCA3E3AD6B426D3E4B, uuid:F3E320E51CF411DDBCABDF64F987667A, uuid:F3E320E51CF411DDBCABDF64F987667A, uuid:060FDD6F69B711DCB907ECDEFCCA1C10, uuid:9E3F50AB69CB11DCB405CEA3FD0362D3, uuid:C5C6BF241D0911DDBCABDF64F987667A, uuid:F3E320E91CF411DDBCABDF64F987667A, uuid:2BEFD898F4DB11DB991BFA1B093C4DED, uuid:2BEFD894F4DB11DB991BFA1B093C4DED, uuid:60AA3E12F4DB11DB991BFA1B093C4DED, uuid:5E6058BB113E11DDB5A38329F750A3A5, uuid:3D87AA9C53BD11DC9897BEE468B83813, uuid:40CB8FB6687611DCA168D72DAA5433AB, uuid:09916AE7A34911DCA7FBFBA6D2A05E54, uuid:A74B23B8136F11DDBE65D7DE8B8806A2, uuid:EB6E67BA176511DDB486823F9D8FBD0B, uuid:978E733C227B11DD8089AE7095C79C6E, uuid:978E733E227B11DD8089AE7095C79C6E, uuid:978E7344227B11DD8089AE7095C79C6E, uuid:B490EAD81CF711DDBCABDF64F987667A, uuid:060FDD6F69B711DCB907ECDEFCCA1C10, uuid:EC2D6DBB1D1211DD9D888B33B886DE79, uuid:B490EAD41CF711DDBCABDF64F987667A, uuid:087E59A71CF811DDBCABDF64F987667A, uuid:B490EADC1CF711DDBCABDF64F987667A, uuid:838C95701D0A11DDBCABDF64F987667A, uuid:3591C8521D1211DDBCABDF64F987667A, uuid:FCEF1488693411DCB7F0C0EECE461212, uuid:83AB02A6693511DCB7F0C0EECE461212, uuid:CB1917F3693511DCB7F0C0EECE461212, uuid:83AB02AB693511DCB7F0C0EECE461212, uuid:5B0C27831CF811DDBCABDF64F987667A, uuid:5B0C27881CF811DDBCABDF64F987667A, uuid:CB1917F8693511DCB7F0C0EECE461212, uuid:838C95681D0A11DDBCABDF64F987667A, uuid:0F40EC5069B911DCB405CEA3FD0362D3, uuid:0F40EC4B69B911DCB405CEA3FD0362D3, uuid:3591C8581D1211DDBCABDF64F987667A, uuid:7398B1071D0A11DDBCABDF64F987667A, uuid:838C956C1D0A11DDBCABDF64F987667A, uuid:A047B7E069B811DCB405CEA3FD0362D3, uuid:A047B7DB69B811DCB405CEA3FD0362D3, uuid:2E33FCC21D0F11DDBCABDF64F987667A, uuid:18F7F50C1D0D11DDBCABDF64F987667A, uuid:D26B2A3F1CF811DDBCABDF64F987667A, uuid:D26B2A3A1CF811DDBCABDF64F987667A, uuid:1D0742071CF911DDBCABDF64F987667A, uuid:D26B2A431CF811DDBCABDF64F987667A, uuid:EE26F8F369BA11DCB405CEA3FD0362D3, uuid:0922C76669BB11DCB405CEA3FD0362D3, uuid:0922C76E69BB11DCB405CEA3FD0362D3, uuid:9291278EFB1011DC9F3BEEC65A0F6863, uuid:9515B35F1D1211DDBCABDF64F987667A, uuid:407CC4A4E7CB11DCA3E3AD6B426D3E4B, uuid:FE788EECE7CB11DCA3E3AD6B426D3E4B, uuid:1D07420B1CF911DDBCABDF64F987667A, uuid:31FBF83CFB2D11DC9F3BEEC65A0F6863, uuid:8AA7232E69BB11DCB405CEA3FD0362D3, uuid:8AA7232E69BB11DCB405CEA3FD0362D3, uuid:D342FFDD69BB11DCB405CEA3FD0362D3, uuid:D342FFE169BB11DCB405CEA3FD0362D3, uuid:C67DECB0FB1111DC9F3BEEC65A0F6863, uuid:dd58e478-11fe-11dd-9cf7-000d93c96644, uuid:458CBB881D0211DDBCABDF64F987667A, uuid:F41C6794E61011DC88A0BDB13F7C92BF, uuid:C5C6BF2C1D0911DDBCABDF64F987667A, uuid:C5C6BF281D0911DDBCABDF64F987667A, uuid:79DDD15169BC11DCB405CEA3FD0362D3, uuid:79DDD15669BC11DCB405CEA3FD0362D3, uuid:02A5E0031D0311DDBCABDF64F987667A, uuid:458CBB911D0211DDBCABDF64F987667A, uuid:C5C6BF2C1D0911DDBCABDF64F987667A, uuid:11618DE669BD11DCB405CEA3FD0362D3, uuid:D0D309F469BC11DCB405CEA3FD0362D3, uuid:66AB192B1D0311DDBCABDF64F987667A, uuid:18F7F50F1D0D11DDBCABDF64F987667A, uuid:02A5E0071D0311DDBCABDF64F987667A, uuid:66AB19271D0311DDBCABDF64F987667A, uuid:C638FBC61D1011DDBCABDF64F987667A, uuid:11618DEF69BD11DCB405CEA3FD0362D3, uuid:332FA34C69BD11DCB405CEA3FD0362D3, uuid:332FA35069BD11DCB405CEA3FD0362D3, uuid:7F009C0C69BD11DCB405CEA3FD0362D3, uuid:9515B3621D1211DDBCABDF64F987667A, uuid:7FA6D82C1D1211DDBCABDF64F987667A, uuid:2E33FCBF1D0F11DDBCABDF64F987667A, uuid:F419B1B51D1011DDBCABDF64F987667A, uuid:E070CFE81D1011DDBCABDF64F987667A, uuid:F419B1AC1D1011DDBCABDF64F987667A, uuid:7FA6D82F1D1211DDBCABDF64F987667A, uuid:AE13FA32E93611DC963BA67F35F9FF9E, uuid:66AB19301D0311DDBCABDF64F987667A, uuid:CAB6C07B1D0311DDBCABDF64F987667A, uuid:5E6058BB113E11DDB5A38329F750A3A5, uuid:A74B23B2136F11DDBE65D7DE8B8806A2, uuid:C638FBC01D1011DDBCABDF64F987667A, uuid:CAB6C07F1D0311DDBCABDF64F987667A, uuid:E3250BB569BD11DCB405CEA3FD0362D3, uuid:55FD91CEFB2B11DC9F3BEEC65A0F6863, uuid:A74B23B2136F11DDBE65D7DE8B8806A2, uuid:81E44A661D0511DDBCABDF64F987667A, uuid:CAB6C07B1D0311DDBCABDF64F987667A, uuid:CAB6C07B1D0311DDBCABDF64F987667A, uuid:FB32630C69BD11DCB405CEA3FD0362D3, uuid:CAB6C07B1D0311DDBCABDF64F987667A, uuid:FB32630C69BD11DCB405CEA3FD0362D3, uuid:81E44A6A1D0511DDBCABDF64F987667A, uuid:34B4B17D1D0611DDBCABDF64F987667A, uuid:A74B23B2136F11DDBE65D7DE8B8806A2, uuid:EBD35830E61211DC88A0BDB13F7C92BF, uuid:16D9CB42DC8911DC97AC8FFCF1F91B5B, uuid:81E44A661D0511DDBCABDF64F987667A, uuid:CAB6C07B1D0311DDBCABDF64F987667A, uuid:9ED7B432FB2A11DC9F3BEEC65A0F6863, uuid:3591C8551D1211DDBCABDF64F987667A, uuid:34B4B1811D0611DDBCABDF64F987667A, uuid:D549163BE61311DC88A0BDB13F7C92BF, uuid:A3C5D8D869BE11DCB405CEA3FD0362D3, uuid:7F4995C5E7D011DCA3E3AD6B426D3E4B, uuid:DBCB17E6E79E11DCA3E3AD6B426D3E4B, uuid:34B4B1851D0611DDBCABDF64F987667A, uuid:34B4B1851D0611DDBCABDF64F987667A, uuid:DDAE31A61D0611DDBCABDF64F987667A, uuid:200791C169BF11DCB405CEA3FD0362D3, uuid:423B029E69BF11DCB405CEA3FD0362D3, uuid:E5B8AC5DE79F11DCA3E3AD6B426D3E4B, uuid:F3E320E11CF411DDBCABDF64F987667A, uuid:0cc21720-179c-11dd-b805-000d93c96644, uuid:A74B23B8136F11DDBE65D7DE8B8806A2, uuid:3D87AA9C53BD11DC9897BEE468B83813, uuid:DDAE31AA1D0611DDBCABDF64F987667A, uuid:423B02A669BF11DCB405CEA3FD0362D3, uuid:7214D80169BF11DCB405CEA3FD0362D3, uuid:7214D80569BF11DCB405CEA3FD0362D3, uuid:BD5E2162E61411DC88A0BDB13F7C92BF, uuid:3FC9F6F66DD311DCABF5D614BA6C5570, uuid:BDEE4520DCD811DC97AC8FFCF1F91B5B, uuid:D42FC0BCDCD911DC97AC8FFCF1F91B5B, uuid:D42FC0BFDCD911DC97AC8FFCF1F91B5B, uuid:BDEE451DDCD811DC97AC8FFCF1F91B5B, uuid:624A57801D0711DDBCABDF64F987667A, uuid:624A57881D0711DDBCABDF64F987667A, uuid:85E79A5F1D0711DDBCABDF64F987667A, uuid:4E610F0E1D0C11DDBCABDF64F987667A, uuid:85E79A681D0711DDBCABDF64F987667A, uuid:85E79A631D0711DDBCABDF64F987667A, uuid:3591C84F1D1211DDBCABDF64F987667A, uuid:E070CFEE1D1011DDBCABDF64F987667A, uuid:23C284B969C011DCB405CEA3FD0362D3, uuid:3B19279369C011DCB405CEA3FD0362D3, uuid:7721B14569C011DCB405CEA3FD0362D3, uuid:2E33FCC61D0F11DDBCABDF64F987667A, uuid:AC1BD4D31D1211DDBCABDF64F987667A, uuid:A86025291D0811DDBCABDF64F987667A, uuid:A86025311D0811DDBCABDF64F987667A, uuid:CA22D0D61D0811DDBCABDF64F987667A, uuid:A74B23B8136F11DDBE65D7DE8B8806A2, uuid:CA22D0DE1D0811DDBCABDF64F987667A, uuid:CA22D0DA1D0811DDBCABDF64F987667A, uuid:AC1BD4D31D1211DDBCABDF64F987667A, uuid:0A6013CF69C111DCB405CEA3FD0362D3, uuid:CDF3200BE79D11DCA3E3AD6B426D3E4B, uuid:B1DCDE0FE78811DCA3E3AD6B426D3E4B, uuid:248BB5F4E79A11DCA3E3AD6B426D3E4B, uuid:879A03381D0F11DDBCABDF64F987667A, uuid:879A033B1D0F11DDBCABDF64F987667A, uuid:F5B6A22D1D0811DDBCABDF64F987667A, uuid:F5B6A2311D0811DDBCABDF64F987667A, uuid:3DA1C5DA69C111DCB405CEA3FD0362D3, uuid:4C0F2DB2686211DCB0CFC2E11F908993, uuid:240EF5E2686511DCB0CFC2E11F908993, uuid:240EF5E7686511DCB0CFC2E11F908993, uuid:5D235AEFE61611DC88A0BDB13F7C92BF, uuid:8CC5876C1D0911DDBCABDF64F987667A, uuid:8CC587701D0911DDBCABDF64F987667A, uuid:9EE69C8E226211DDA0939F645741ED4F, uuid:AC81D478024311DD9A72867D861050E9 Manifest Reference Document ID : uuid:4CA76D79E7EE11DCA3E3AD6B426D3E4B, uuid:585FBDB0DEEA11DC9498BA1D7E5386F9, uuid:585FBDB0DEEA11DC9498BA1D7E5386F9, uuid:060FDD6E69B711DCB907ECDEFCCA1C10, uuid:46839D5BF4C911DB991BFA1B093C4DED, uuid:F36D75F1F4C811DB991BFA1B093C4DED, uuid:363F96B4F4C711DB991BFA1B093C4DED, uuid:2BEFD897F4DB11DB991BFA1B093C4DED, uuid:2BEFD893F4DB11DB991BFA1B093C4DED, uuid:60AA3E11F4DB11DB991BFA1B093C4DED, uuid:4FBE0319A34B11DCB69A969863D4FD55, uuid:FBE9699C53B011DC9897BEE468B83813, uuid:F986088F687411DCA168D72DAA5433AB, uuid:09916AE6A34911DCA7FBFBA6D2A05E54, uuid:A74B23B6136F11DDBE65D7DE8B8806A2, uuid:EB6E67B8176511DDB486823F9D8FBD0B, uuid:978E733B227B11DD8089AE7095C79C6E, uuid:978E733D227B11DD8089AE7095C79C6E, uuid:978E7343227B11DD8089AE7095C79C6E, uuid:1929A46CDEE111DC9498BA1D7E5386F9, uuid:060FDD6E69B711DCB907ECDEFCCA1C10, uuid:8D3F0D9AF65311DB8126C54713534A8F, uuid:19F869D2A33711DCA7FBFBA6D2A05E54, uuid:FFA7E17FE86C11DC8782A48D3393993E, uuid:EEF44A4EE60311DC88A0BDB13F7C92BF, adobe:docid:photoshop:c7070594-3061-11d7-a4ad-e5231b1ffc5c, uuid:41307DF8D05611DAAE8CCC8BE6271632, adobe:docid:photoshop:d86411df-3061-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:e6b843f2-3061-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:bd9dcc80-3060-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:645cbc5d-64f0-11d7-b15a-a152063338e9, adobe:docid:photoshop:d17dd49d-305f-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:dafcc8a6-305f-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:8a3b7c35-3061-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:6d77207c-87ca-11d7-a001-bfb59e05bac9, adobe:docid:photoshop:22f574c3-3060-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:84f936e3-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:92bcf1d2-3062-11d7-a4ad-e5231b1ffc5c, uuid:C5057BC3680F11DC865DD4C620617CC7, adobe:docid:photoshop:b6f100fb-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:c5485fba-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:7ac87833-3060-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:7ac87837-3060-11d7-a4ad-e5231b1ffc5c, uuid:A8C68E84FB0B11DC9F3BEEC65A0F6863, uuid:5F7DA5F2682111DC865DD4C620617CC7, uuid:5F7DA5F6682111DC865DD4C620617CC7, adobe:docid:photoshop:6a778e59-3062-11d7-a4ad-e5231b1ffc5c, uuid:FDBEAD16FB0B11DC9F3BEEC65A0F6863, adobe:docid:photoshop:062f39aa-9c03-11d7-9e81-aec98a73a22f, uuid:5F7DA5FC682111DC865DD4C620617CC7, uuid:697DD407682211DC865DD4C620617CC7, uuid:7C61FE02682311DC865DD4C620617CC7, uuid:92912789FB1011DC9F3BEEC65A0F6863, uuid:D0F7EDE1682711DC865DD4C620617CC7, uuid:407CC4A3E7CB11DCA3E3AD6B426D3E4B, uuid:FE788EEBE7CB11DCA3E3AD6B426D3E4B, uuid:926B3981FB3A11DC9F3BEEC65A0F6863, uuid:31FBF83BFB2D11DC9F3BEEC65A0F6863, uuid:440DA15D682511DC865DD4C620617CC7, uuid:440DA15D682511DC865DD4C620617CC7, uuid:7901BEB9682811DC865DD4C620617CC7, uuid:E2FCDCAC682811DC865DD4C620617CC7, uuid:7901BEB2682811DC865DD4C620617CC7, uuid:7DF9678F726611DC8E7EE63BA6560C67, uuid:EA7769A5FB6211DC9F3BEEC65A0F6863, adobe:docid:photoshop:58885582-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:472101d9-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:472101d1-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:6de9b4a4-305f-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:6de9b49c-305f-11d7-a4ad-e5231b1ffc5c, uuid:817EF08868FE11DCB7F0C0EECE461212, adobe:docid:photoshop:a03552e9-7e46-11d7-8da7-fe227350e563, adobe:docid:photoshop:472101d9-3062-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:5310b494-305d-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:10e010f5-3063-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:dd1e22b7-305e-11d7-a4ad-e5231b1ffc5c, uuid:4CAA41EDD05511DAAE8CCC8BE6271632, adobe:docid:photoshop:daeb8a05-6903-11dc-a5d7-b6ca52622597, uuid:4CAA41EDD05511DAAE8CCC8BE6271632, uuid:CDF3200FE79D11DCA3E3AD6B426D3E4B, uuid:C037D6BA683C11DCB0CFC2E11F908993, uuid:C037D6BF683C11DCB0CFC2E11F908993, adobe:docid:photoshop:3dc10559-3060-11d7-a4ad-e5231b1ffc5c, uuid:9C6953B5683D11DCB0CFC2E11F908993, uuid:7071CDD7E7CD11DCA3E3AD6B426D3E4B, uuid:14B228E6E7CE11DCA3E3AD6B426D3E4B, uuid:AA45D91AE7CE11DCA3E3AD6B426D3E4B, uuid:14B228E1E7CE11DCA3E3AD6B426D3E4B, uuid:6B872466E7CF11DCA3E3AD6B426D3E4B, uuid:7071CDD2E7CD11DCA3E3AD6B426D3E4B, uuid:AA45D91FE7CE11DCA3E3AD6B426D3E4B, uuid:AA45D924E7CE11DCA3E3AD6B426D3E4B, uuid:3B5E5739684D11DCA168D72DAA5433AB, uuid:1B7705AB691B11DCB7F0C0EECE461212, uuid:4FBE0319A34B11DCB69A969863D4FD55, uuid:DDB01339E49011DCA2C7B54E5F3FF90F, uuid:0CDA29D9DC8311DC97AC8FFCF1F91B5B, uuid:4F5506E025A911DB9108F562C016C5C1, uuid:0B32EEA0693211DCB7F0C0EECE461212, uuid:9ED7B43AFB2A11DC9F3BEEC65A0F6863, uuid:DDB01339E49011DCA2C7B54E5F3FF90F, uuid:BB237937692E11DCB7F0C0EECE461212, uuid:1B7705AB691B11DCB7F0C0EECE461212, uuid:1B7705AB691B11DCB7F0C0EECE461212, uuid:27CD923F693111DCB7F0C0EECE461212, uuid:1B7705AB691B11DCB7F0C0EECE461212, uuid:27CD923F693111DCB7F0C0EECE461212, uuid:94C3108EE93711DC963BA67F35F9FF9E, uuid:D007AAF1E93711DC963BA67F35F9FF9E, uuid:DDB01339E49011DCA2C7B54E5F3FF90F, uuid:985D7FAD684811DCB0CFC2E11F908993, uuid:0CDA29DEDC8311DC97AC8FFCF1F91B5B, uuid:BB237937692E11DCB7F0C0EECE461212, uuid:1B7705AB691B11DCB7F0C0EECE461212, uuid:B095B409FB2711DC9F3BEEC65A0F6863, uuid:13C3F687DD6711DCAFDCEE2AE297F702, uuid:2BF0D74EFB6311DC9F3BEEC65A0F6863, uuid:E8731790684A11DCB0CFC2E11F908993, uuid:0C6C37B5684A11DCB0CFC2E11F908993, uuid:7F4995C4E7D011DCA3E3AD6B426D3E4B, uuid:DBCB17DFE79E11DCA3E3AD6B426D3E4B, uuid:9DB0347DFB3E11DC9F3BEEC65A0F6863, uuid:9DB0347DFB3E11DC9F3BEEC65A0F6863, uuid:2709DFCBE93811DC963BA67F35F9FF9E, uuid:4C0F2DB7686211DCB0CFC2E11F908993, uuid:796EC486691511DCB7F0C0EECE461212, uuid:E5B8AC59E79F11DCA3E3AD6B426D3E4B, uuid:136D97F44206DD1190A0B0C0941830BB, uuid:5657A424190811DDB795F3FFFCB9EFBA, uuid:A74B23B6136F11DDBE65D7DE8B8806A2, uuid:FBE9699C53B011DC9897BEE468B83813, adobe:docid:photoshop:3206f59d-71ad-11d7-b82a-f8ec1d29e726, uuid:53731259690411DCB7F0C0EECE461212, uuid:70DD6A91685111DCB0CFC2E11F908993, uuid:C9677D66685111DCB0CFC2E11F908993, uuid:10C1EA42685511DCB0CFC2E11F908993, uuid:3FC9F6F56DD311DCABF5D614BA6C5570, uuid:91DAB7FFDCD811DC97AC8FFCF1F91B5B, uuid:91DAB803DCD811DC97AC8FFCF1F91B5B, uuid:BDEE4516DCD811DC97AC8FFCF1F91B5B, uuid:47B8C874DCB711DC97AC8FFCF1F91B5B, uuid:6D1EF124685911DCB0CFC2E11F908993, uuid:47B8C86CDCB711DC97AC8FFCF1F91B5B, uuid:7CC8E29FDCA911DC97AC8FFCF1F91B5B, uuid:70DD6A95685111DCB0CFC2E11F908993, adobe:docid:photoshop:acef9def-305d-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:a24b5268-305d-11d7-a4ad-e5231b1ffc5c, uuid:5DF1F892DCE311DC97AC8FFCF1F91B5B, uuid:DE7B12CCDCE311DC97AC8FFCF1F91B5B, adobe:docid:photoshop:05f2a956-305f-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:05f2a952-305f-11d7-a4ad-e5231b1ffc5c, adobe:docid:photoshop:c570eca6-305f-11d7-a4ad-e5231b1ffc5c, uuid:05EEECB2685D11DCB0CFC2E11F908993, uuid:B3C65FD1CC1311DC93D9D994E0A2CEFF, uuid:05EEECB7685D11DCB0CFC2E11F908993, uuid:06561F58FB3C11DC9F3BEEC65A0F6863, uuid:C520B606137711DD91D7B304716E8DDD, uuid:A74B23B6136F11DDBE65D7DE8B8806A2, uuid:4A2EADED138011DD91D7B304716E8DDD, uuid:612B07AE138111DD91D7B304716E8DDD, uuid:B3C65FD1CC1311DC93D9D994E0A2CEFF, uuid:D6EE2BF1685D11DCB0CFC2E11F908993, uuid:CDF3200AE79D11DCA3E3AD6B426D3E4B, uuid:B1DCDE0EE78811DCA3E3AD6B426D3E4B, uuid:248BB5F3E79A11DCA3E3AD6B426D3E4B, uuid:248BB5F8E79A11DCA3E3AD6B426D3E4B, uuid:6F1648E2DBDC11DC8014FDC41C3D3B4D, uuid:86B54DBF685F11DCB0CFC2E11F908993, uuid:6F82096F686111DCB0CFC2E11F908993, uuid:6F820976686111DCB0CFC2E11F908993, uuid:4C0F2DB1686211DCB0CFC2E11F908993, uuid:240EF5E1686511DCB0CFC2E11F908993, uuid:240EF5E6686511DCB0CFC2E11F908993, uuid:84F84359690111DC815BD4FBD2A29AD9, uuid:38E289C67CBF11DCA6F0FED484422BD0, uuid:48B9EE84DED411DC9EC5C226BBA073A4, uuid:5A35D981024311DD9A72867D861050E9, uuid:AC81D477024311DD9A72867D861050E9 Metadata Date : 2011:08:08 16:11:35-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 15996 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 88EXIF Metadata provided by EXIF.tools