0024 GDX5 LITE LOW RISE INDIGO ACCESS.sdr GDX 123121 Datasheet
GDX - 23121- datasheet GDX - 23121- datasheet
0024 GDX5 LITE LOW RISE INDIGO ACCESS 0024 GDX5 LITE LOW RISE INDIGO ACCESS
0024 GDX5 LITE LOW RISE INDIGO ACCESS 0024 GDX5 LITE LOW RISE INDIGO ACCESS
GDX - 23121 - datasheet GDX - 23121 - datasheet
GDX - 23121- datasheet GDX - 23121- datasheet
User Manual: GDX - 123121 - datasheet
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
GDX5 LITE 8, 16, 24 OR 32 WAY LOW RISE INDIGO ACCESS AUDIO DOOR ENTRY SYSTEM CONNECTION SCHEMATIC GDX HANDSET 1 1 2 3 GDX HANDSET 8 THE CABLING SPECIFICATIONS QUOTED ARE NOT VALID FOR UNDERGROUND CABLING. 9705/002 APARTMENT STATION WIRING IS IDENTICAL TO HANDSET WIRING. 9705/002 ALL POWER CABLE SPECIFICATIONS GIVEN ARE ILLUSTRATIVE ONLY AND MUST BE SELECTED DEPENDANT ON SITE SPECIFIC CABLE LENGTHS AND LOCK TYPES TO AVOID EXCESSIVE VOLTAGE DROP WITHIN CABLING. 4 DRAWING NO : 0024 1 2 3 APARTMENT STATION WIRING IS IDENTICAL TO HANDSET WIRING. 4 3 PAIR CW1308 CABLE (MAXIMUM 50 METRES) ORANGE/WHITE If This Is Still Not Effective Then A Ferrite Core (Steward Part No 28B1020-100) Should Be Added Onto The Handset Cabling Output Within The Control Rack Enclosure (Grouped In 4's). BLUE/WHITE WHITE/BLUE If This Is Not Effective In Dealing With The Problem Then A Suitable Screened Cable Can Be Utilised To Prevent The Pickup. ORANGE/WHITE BLUE/WHITE WHITE/BLUE WHITE/ORANGE 3 PAIR CW1308 CABLE (MAXIMUM 50 METRES) WHITE/ORANGE If Radio Interference Is Picked Up On The Handset Cabling Then Unconnected Cores Within A Handset Cable Should Be Grounded to 0V (No 3 Screw) At Both Ends Of The Cable. A PARALLEL SLAVE HANDSET CAN BE ADDED ONTO A MAIN HANDSET. 1 2 3 TEL 1 4 1 2 3 TEL 2 4 1 2 3 TEL 3 4 1 2 3 TEL 4 4 1 2 3 TEL 5 GDX5 16 WAY LINECARD 1 2 3 TEL 9 4 1 2 3 TEL 10 4 1 2 3 4 TEL 11 Setting Default Location Service Period 1 07:00-09:00 Door Service Period 2 00:00-00:00 Door Sunday Service On Door 1 2 3 TEL 12 4 1 2 3 TEL 6 0105/001 4 1 4 1 2 3 TEL 7 4 1 2 3 TEL 8 2 3 4 TEL 15 1 2 3 4 TEL 16 118043 2 3 4 TEL 13 1 2 3 TEL 14 4 1 LCD INFORMATION DISPLAY As Required Door CANL 4 Secs Door CANH Pre-Answer 30 Secs Door 40 Secs Door 8 Secs Door Door Alarm Time 5 Mins Door Timed Privacy Time 6 Hours Control Card DOOR 1 Time/Date Post-Answer LOCK 0V LOCK 12V 0V UNREG DOOR 0 CANL CANH BLACK LOCK 0V CHANNEL 2 0V TX+ TX- RX+ RX- TX+ TX- RX+ RX- UNREG RED BLUE/WHITE WHITE/BLUE GDX5 LITE 8 OR 16 WAY CONTROL UNIT GREEN/WHITE WHITE/GREEN ORANGE/WHITE WHITE/ORANGE LOCK 12V CHANNEL 1 BROWN/WHITE WHITE/BROWN ONLY 1 PARALLEL SLAVE HANDSET CAN ADDED PER MAIN HANDSET. THIS APPLIES TO APT STATIONS ALSO BUT NOT TO VIDEO HANDSETS. ONLY A SLAVE AUDIO HANDSET CAN BE ADDED ONTO A MAIN VIDEO HANDSET. Call Tone Length Lock Release Time REMOVE LINKS LK1 & LK2 IN THE 2ND HANDSET ONLY AND CONNECT WIRES 1,2,3,4 & "EXT PRIV+" BETWEEN THE TWO HANDSETS. 4 NOTE THE CABLING CROSSOVER BETWEEN RX AND TX AUDIO CONNECTIONS. 2 CORE 0.5mm FLEX (FOR LOCK) RED BLACK BROWN/WHITE GREEN/WHITE WHITE/BROWN WHITE/GREEN ORANGE/WHITE BLUE/WHITE WHITE/ORANGE WHITE/BLUE 6 PAIR CW1308 CABLE (MAXIMUM 100 METRES) MOV MUST BE FITTED AT LOCK LOCK DOOR CONTACT FIRE EXIT (NOTE1) AS THE LOCK RELEASE, PUSH TO EXIT AND FIREMAN'S SWITCH ALL CARRY THE LOCK CURRENT THEY SHOULD BE RATED ACCORDINGLY ie. 0.5mm 2 CORE FLEX OR SUITABLE TO EACH ONE. (DOES NOT APPLY TO DOOR CONTACT) NOTE 1 : DO NOT USE THE CONTACTS WITHIN MAGNETIC LOCKS FOR THE DOOR CONTACT. USE SECURITY CONTACTS INSTEAD FOR DOOR OPEN INDICATION IF REQUIRED. UN 0V REG CAN CAN TX+ TXH L RX+ RX- +12V 0V LOCK PWR NC CONT FIRE NC CONT PTE +12V 0V LOCK NC CONT TOKEN DOOR SW- GDX5 COMPACT DOOR CONTROL CARD PRINTED CIRCUIT BOARD (9905/003) DOOR 0 CHANNEL 1 ENTRANCE PANEL DOOR NUMBER AND AUDIO CHANNEL SETTINGS FACTORY PROGRAMMED INTO THE DOOR ARE DISPLAYED ON THE DOOR LCD AT POWER UP. LITE PANELS REQUIRE ONLY AN AUDIO CHANNEL TO BE SET ON THEM. ALL LITE PANELS ARE FACTORY SET AS DEFAULT TO AUDIO CHANNEL 1. A SECOND PANEL ADDED TO A SYSTEM MUST BE RE-ADDRESSED AS AUDIO CHANNEL 2. TWO CAN HEADER TERMINATION LINKS MUST BE FITTED ON A SYSTEM TO BALANCE THE COMMUNICATIONS DATA BUS.. THESE ARE NORMALLY FITTED ON THE CONTROL UNIT CARD AND THE FIRST DOOR. REMOVE THIS LINK IF FITTED ON THE SECOND DOOR. POWER REQUIREMENTS THE CONTROL UNIT REQUIRES A MAINS INPUT OF 220VAC / 240VAC 50/60 Hz AND A SUITABLE EARTH CONNECTION INTO THE SWITCHED FUSED SPUR. THIS EARTH CONNECTION PROVIDES THE SAFETY EARTH FOR THE CONTROL UNIT ENCLOSURE AND BACKPLATE. The following table gives the location, type and rating of each fuse utilised Ref Name / Location Type FM Mains Fuse Within Spur 240VAC HBC Quick Acting Rating 3A FS1 Board Fuse On Linecard * 20mm Glass Quick Blow 3A / 6A ** FS2 - FS5 Door Fuses On Linecard * 20mm Glass Quick Blow 1.6A * Fuses Located In Vertical Fuse Holders On Card ** Select Depending On Power Requirements Of Door Locks Used REAL TIME CLOCK IC IF SYSTEM IS A 2 DOOR SYSTEM THEN THE 2ND DOOR OR STAND ALONE TOKEN ACCESS READER IS CONNECTED AS SHOWN FOR THE 1ST ONE EXCEPT USING THE DOOR 1 CHANNEL 2 CONNECTIONS. (A STAND ALONE TOKEN ACCESS READER WILL NOT REQUIRE THE AUDIO CHANNEL CONNECTIONS) THE READER MUST BE ADDRESSED AS THE NEXT AVAILABLE DOOR NUMBER ON THE SYSTEM AFTER THE DOORS HAVE BEEN NUMBERED. GDX Technologies Ltd 61-63 Back Sneddon St, Paisley Renfrewshire. PA3 2DD 0024 GDX5 LITE LOW RISE INDIGO ACCESS.SDR VERSION 1.02 18/12/04
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2005:06:29 16:01:20+01:00 Modify Date : 2005:06:29 16:01:20+01:00 Page Count : 1 Creation Date : 2005:06:29 15:01:20Z Mod Date : 2005:06:29 15:01:20Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : DavidM Metadata Date : 2005:06:29 15:01:20Z Creator : DavidM Title : 0024 GDX5 LITE LOW RISE INDIGO ACCESS.sdrEXIF Metadata provided by EXIF.tools