0024 GDX5 LITE LOW RISE INDIGO ACCESS.sdr GDX 123121 Datasheet

GDX - 23121- datasheet GDX - 23121- datasheet

0024 GDX5 LITE LOW RISE INDIGO ACCESS 0024 GDX5 LITE LOW RISE INDIGO ACCESS

0024 GDX5 LITE LOW RISE INDIGO ACCESS 0024 GDX5 LITE LOW RISE INDIGO ACCESS

GDX - 23121 - datasheet GDX - 23121 - datasheet

GDX - 23121- datasheet GDX - 23121- datasheet

User Manual: GDX - 123121 - datasheet

Open the PDF directly: View PDF PDF.
Page Count: 1

GDX5 LITE 8, 16, 24 OR 32 WAY LOW RISE INDIGO ACCESS AUDIO DOOR ENTRY SYSTEM CONNECTION SCHEMATIC DRAWING NO : 0024
GDX Technologies Ltd 61-63 Back Sneddon St, Paisley Renfrewshire. PA3 2DD
THE CABLING SPECIFICATIONS QUOTED ARE
NOT VALID FOR UNDERGROUND CABLING.
6 PAIR CW1308 CABLE
(MAXIMUM 100 METRES)
2 CORE 0.5mm FLEX (FOR LOCK)
GDX5 COMPACT DOOR CONTROL CARD PRINTED CIRCUIT BOARD (9905/003)
AS THE LOCK RELEASE, PUSH TO EXIT AND FIREMAN'S SWITCH ALL
CARRY THE LOCK CURRENT THEY SHOULD BE RATED ACCORDINGLY
ie. 0.5mm 2 CORE FLEX OR SUITABLE TO EACH ONE.
(DOES NOT APPLY TO DOOR CONTACT)
0024 GDX5 LITE LOW RISE INDIGO ACCESS.SDR VERSION 1.02 18/12/04
DOOR 0 CHANNEL 1 ENTRANCE PANEL
ALL POWER CABLE SPECIFICATIONS GIVEN ARE
ILLUSTRATIVE ONLY AND MUST BE SELECTED DEPENDANT
ON SITE SPECIFIC CABLE LENGTHS AND LOCK TYPES
TO AVOID EXCESSIVE VOLTAGE DROP WITHIN CABLING.
GDX5 LITE 8 OR 16 WAY CONTROL UNIT
NOTE 1 :
DO NOT USE THE CONTACTS WITHIN MAGNETIC LOCKS
FOR THE DOOR CONTACT. USE SECURITY CONTACTS
INSTEAD FOR DOOR OPEN INDICATION IF REQUIRED.
1234
TEL 1
1234
TEL 2
1234
TEL 15
1234
TEL 16
UNREG
0V
LOCK 12V
LOCK 0V
CANH
CANL
3 PAIR CW1308 CABLE
(MAXIMUM 50 METRES)
WHITE/GREEN
GREEN/WHITE
WHITE/BROWN
BROWN/WHITE
TX+ TX- RX+ RX-
CHANNEL 1
TX+ TX- RX+ RX-
CHANNEL 2
DOOR 0
1234
TEL 9
1234
TEL 10
GDX5 16 WAY LINECARD 0105/001 118043
UNREG
0V
LOCK 12V
LOCK 0V
CANH
CANL
DOOR 1
GDX HANDSET 1
1234
9705/002
WHITE/BLUE
WHITE/ORANGE
BLUE/WHITE
ORANGE/WHITE
1234
TEL 7
1234
TEL 8
1234
TEL 3
1234
TEL 4
1234
TEL 11
1234
TEL 12
1234
TEL 5
1234
TEL 6
1234
TEL 13
1234
TEL 14
GDX HANDSET 8
WHITE/BLUE
WHITE/ORANGE
BLUE/WHITE
ORANGE/WHITE
LCD INFORMATION DISPLAY
TOKEN
SW-
NC CONT
DOOR
+12V 0V
LOCK
NC CONT
PTE
NC CONT
FIRE
CAN CAN
H L
UN 0V
REG
RX+ RX-TX+ TX- +12V 0V
LOC K PWR
REAL TIME CLOCK IC
DOOR
CONTACT
EXIT
LOCK
FIRE
WHITE/BLUE
BLUE/WHITE
WHITE/ORANGE
ORANGE/WHITE
3 PAIR CW1308 CABLE
(MAXIMUM 50 METRES)
RED
BLACK
IF SYSTEM IS A 2 DOOR SYSTEM THEN THE 2ND DOOR OR STAND ALONE TOKEN ACCESS READER IS CONNECTED AS SHOWN FOR THE 1ST ONE
EXCEPT USING THE DOOR 1 CHANNEL 2 CONNECTIONS. (A STAND ALONE TOKEN ACCESS READER WILL NOT REQUIRE THE AUDIO CHANNEL CONNECTIONS)
THE READER MUST BE ADDRESSED AS THE NEXT AVAILABLE DOOR NUMBER ON THE SYSTEM AFTER THE DOORS HAVE BEEN NUMBERED.
1234
9705/002
MOV MUST BE FITTED AT LOCK
(NOTE1)
WHITE/GREEN
GREEN/WHITE
BROWN/WHITE
WHITE/BROWN
WHITE/BLUE
BLUE/WHITE
WHITE/ORANGE
ORANGE/WHITE
RED
BLACK
NOTE THE CABLING CROSSOVER BETWEEN
RX AND TX AUDIO CONNECTIONS.
Setting Default Location
Service Period 1 07:00-09:00 Door
Service Period 2 00:00-00:00 Door
Sunday Service On Door
Time/Date As Required Door
Call Tone Length 4Secs Door
Pre-Answer 30 Secs Door
Post-Answer 40 Secs Door
Lock Release Time 8Secs Door
Door Alarm Time 5Mins Door
Timed Privacy Time 6 Hours Control Card
If Radio Interference Is Picked Up On The Handset Cabling
Then Unconnected Cores Within A Handset Cable Should Be
Grounded to 0V (No 3 Screw) At Both Ends Of The Cable.
If This Is Not Effective In Dealing With The Problem Then A
Suitable Screened Cable Can Be Utilised To Prevent The Pickup.
If This Is Still Not Effective Then A Ferrite Core (Steward Part
No 28B1020-100) Should Be Added Onto The Handset Cabling
Output Within The Control Rack Enclosure (Grouped In 4's).
POWER REQUIREMENTS
THE CONTROL UNIT REQUIRES A MAINS INPUT OF 220VAC /
240VAC 50/60 Hz AND A SUITABLE EARTH CONNECTION INTO
THE SWITCHED FUSED SPUR. THIS EARTH CONNECTION
PROVIDES THE SAFETY EARTH FOR THE CONTROL UNIT
ENCLOSURE AND BACKPLATE.
DOOR NUMBER AND AUDIO CHANNEL SETTINGS FACTORY PROGRAMMED
INTO THE DOOR ARE DISPLAYED ON THE DOOR LCD AT POWER UP.
LITE PANELS REQUIRE ONLY AN AUDIO CHANNEL TO BE SET ON THEM. ALL
LITE PANELS ARE FACTORY SET AS DEFAULT TO AUDIO CHANNEL 1. A SECOND
PANEL ADDED TO A SYSTEM MUST BE RE-ADDRESSED AS AUDIO CHANNEL 2.
TWO CAN HEADER TERMINATION LINKS MUST BE FITTED ON A SYSTEM TO
BALANCE THE COMMUNICATIONS DATA BUS.. THESE ARE NORMALLY FITTED
ON THE CONTROL UNIT CARD AND THE FIRST DOOR. REMOVE THIS LINK IF
FITTED ON THE SECOND DOOR.
APARTMENT STATION
WIRING IS IDENTICAL
TO HANDSET WIRING.
APARTMENT STATION
WIRING IS IDENTICAL
TO HANDSET WIRING.
A PARALLEL SLAVE HANDSET CAN
BE ADDED ONTO A MAIN HANDSET.
REMOVE LINKS LK1 & LK2 IN THE
2ND HANDSET ONLY AND CONNECT
WIRES 1,2,3,4 & "EXT PRIV+"
BETWEEN THE TWO HANDSETS.
ONLY 1 PARALLEL SLAVE HANDSET
CAN ADDED PER MAIN HANDSET.
THIS APPLIES TO APT STATIONS ALSO
BUT NOT TO VIDEO HANDSETS. ONLY
A SLAVE AUDIO HANDSET CAN BE
ADDED ONTO A MAIN VIDEO HANDSET.
Ref Name / Location Type Rating
FM Mains Fuse Within Spur 240VAC HBC Quick Acting 3A
FS1 Board Fuse On Linecard * 20mm Glass Quick Blow 3A / 6A **
FS2 - FS5 Door Fuses On Linecard * 20mm Glass Quick Blow 1.6A
* Fuses Located In Vertical Fuse Holders On Card
** Select Depending On Power Requirements Of Door Locks Used
The following table gives the location, type and rating of each fuse utilised -

Navigation menu