For updated timers and manuals http://waterheatertimer.org/Intermatic-timers-and-manuals.html TIMERS GRASSLIN DEFROST TIMER GRASSLIN DTMV SERIES SPECIFIERS GUIDE TIMERS Furnish and install a Grasslin DTMV40 defrost control which is field adjustable for 120V or 240V operation and shall have defrost initiation times settable to the quarter hour via captive trippers at 15 minute intervals. The defrost timer shall be housed in a NEMA 3R indoor/outdoor plastic enclosure. The relay output will be rated for 40A Resistive, 2HP @ 250VAC. Defrost termination to be by time (and by a remote temperature or pressure switch). SPECIFICATIONS Switch Rating: 40A Resistive @ 120VAC, 208~240VAC 2HP @ 208~240VAC; 1HP @ 120VAC 16FLA, 90LRA @ 120VAC 12FLA, 52LRA @ 240VAC “F” Terminal: 30A Resistive @ 120~240VAC 1HP @ 120VAC; 2HP @ 208~240VAC Wiring Connections: Screw box lug terminals accommodate up to four #8 AWG wires. Environmental Ratings: Operating Temperature Range: –40°F to 131°F (–40°C to 55°C) Operating Humidity: 0 to 95% non-condensing Dimensions: 8.795” x 6.631” x 2.935” (H x W x D) Shipping Weight: 2 lbs. Ordering Data Time Initiated, Remote Temperature, Pressure, or Time Terminated PART NO VOLTAGE MOUNTING TIMER DTMV40 120V, 208/240V, 60Hz Synchronous DTMV40-M DTMV40-B20 DTMV40-P DTQMV40 120V, 208/240V, 60Hz 120V, 208/240V, 60Hz 120V, 208/240V, 60Hz 120V, 208/240V, 60Hz Synchronous Synchronous Synchronous Quartz DTQMV40-M DTQMV40-B DTQMV40-P DT140 Digi 20-120 120V, 208/240V, 60Hz 120V, 208/240V, 60Hz 120V, 208/240V, 60Hz 120V, 50/60Hz DT140 Digi 20-240 208/240V, 50/60Hz NEMA 3R Outdoor Enclosure Mechanism Only Bracket Mount Panel Mount NEMA 3R Outdoor Enclosure Mechanism Only Bracket Mount Panel Mount NEMA 3R Outdoor Enclosure NEMA 3R Outdoor Enclosure BATTERY BACK-UP Duration N/A DEFROST FREQUENCY DURATION NO/DAY 1 to 24 15-180 min. MINIMUM DURATION INTERVAL 15 minutes N/A N/A N/A 1 week 1 to 24 1 to 24 1 to 24 1 to 24 15-180 min. 15-180 min. 15-180 min. 15-180 min. 15 minutes 15 minutes 15 minutes 15 minutes Quartz Quartz Quartz Electronic* 1 week 1 week 1 week 1 week 1 to 24 1 to 24 1 to 24 1 to 8 15-180 min. 15-180 min. 15-180 min. 1-180 min. 15 minutes 15 minutes 15 minutes 1 minute Electronic* 1 week 1 to 8 1-180 min. 1 minute Standard models are also available with 50Hz input in 208/240V *Rated at 30 Amps Universal Replacement PARAGON GRASSLIN = DTMV 40 8141-00 8143-00 8145-00 8041-00 8043-00 8045-00 8046-00 8047-00 8141-20 8143-20 8145-20 8041-20 8043-20 8045-20 8046-20 8047-20 8245-20* 8243-20* 8247-20* PRECISION 6141-00 6143-00 6145-00 6041-00 6043-00 6045-00 Recommended Pressure Switches: Johnson/Penn P170, Ranco 010 series, or Danfoss KP1 series. Pressure range approximately 35-110psi, Cut-in on pressure rise 6047-00 6141-20 6143-20 6145-20 6041-20 6043-20 6045-20 6047-20 6245-20 6243-20 6247-20 364 TIMERS GRASSLIN GENERAL PURPOSE TIMER (24-Hour, 7-Day) Multivoltage — Accepts 120, 240 or 277 Input Voltages The GM1 and GMD units are universal commercial time switches that are fieldselectable for 120, 208 and 240 or 277 VAC (50 or 60 Hz) – all within the same unit. All units are 40A rated. The GMX time Switches are voltage-specific, offering 4 pole 32A contacts. All commercial time controls come standard in a high quality plastic enclosure; Metal enclosures are optional. TIMERS 24-Hour PART NO GM1-ST-I-MV GMD-ST-I-MV GMD1SW-I-MV GMX SW-I-4P32-120 GMX SW-I-4P32-240 DESCRIPTION REPLACES PARAGON 24 Hr., Synchronous, SPDT Switch 24 Hr., Synchronous, DPDT Switch 7 Day, Synchronous, DPDT Switch 7 Day, Synchronous with 4-Pole 32A Contactor 7 Day, Synchronous with 4-Pole 20A Contactor 4001 & P101 4003-00 & 4004-71 7008 7008-00 7008-71 24-Hour, Battery Backup PART NO GM1 QT-“I”-MV GMD QT-“I”-MV TIMER VOLTAGE SWITCH 120, 208/240, 277 V 120, 208/240, 277 V SPDT DPDT AMPS 30 30 7-Day PART NO GM1 SW-“I”-MV GMD SW-“I”-MV TIMER VOLTAGE SWITCH 120, 208/240, 277 V 120, 208/240, 277 V SPDT DPDT TIMER VOLTAGE SWITCH 120, 208/240, 277 V 120, 208/240, 277 V SPDT DPDT AMPS 30 30 7-Day, Battery Backup PART NO GM1 QW-“I”-MV GMD QW-“I”-MV 365 AMPS 30 30 TIMERS TIMERS GRASSLIN GENERAL PURPOSE TIMER GM40 Amber and Green LED Lights Indicate Power and Status Easy Multi-Voltage Field Adjustable DIP Switch for 120, 208/240 or 277 VAC New Compact VALOX® NEMA 3R Outdoor Enclosure Replaces All Metal Enclosures Large Screw Terminals for Easy Wiring #8 AWG Ground Lug Termination Captive Trippers Can’t Be Lost Independently Adjustable Trippers at 15 Minute Intervals Real Time Clock Face NO TOOLS REQUIRED! Our “GUTS” simply snap into existing Grasslin or Intermatic enclosures 40 Amp Rated Contacts Moisture Resistant Conformal Coated Board PART NO GM40 GM40Q GM40W GM40QW DESCRIPTION VOLTAGE OUTPUT 24-HOUR ELECTROMECHANICAL, MULTI-VOLTAGE, SPDT, NEMA 3R OUTDOOR ENCLOSURE 24-HOUR ELECTROMECHANICAL, MULTI-VOLTAGE, SPDT, NEMA 3R OUTDOOR ENCLOSURE 7-DAY (SKIP-A-DAY/WEEKLY) ELECTROMECHANICAL, MULTI-VOLTAGE, SPDT/DPDT, NEMA 3R OUTDOOR ENCLOSURE 7-DAY (SKIP-A-DAY/WEEKLY) ELECTROMECHANICAL, MULTI-VOLTAGE, SPDT/DPDT, NEMA 3R OUTDOOR ENCLOSURE 120, 208-240, 277VAC 40A DPDT BATTERY BACKUP NO 120, 208-240, 277VAC 40A DPDT YES 120, 208-240, 277VAC 40A DPDT NO 120, 208-240, 277VAC 40A DPDT YES 366 WILL REPLACE GM1ST-I-MV & GMDST-I-MV GM1QT-I-MV & GMDQT-I-MV GM1SW-I-MV & GMDSW-I-MV GM1QW-I-MV & GMDQW-I-MV TIMERS GRASSLIN GMX SERIES (24-Hour, 7-Day) • Inexpensive general purpose timer. • 21A, 2HP @ 240V switch. • Indoor or outdoor enclosure. • Captive trippers with interval of 15 minutes on 24-hour model. • Easy to set clock face timer. • Optional clear cover allows viewing timer clock face without opening cover. TIMERS Enclosure Options, Substitute the Following for “X”: “I” = NEMA 1 Indoor Enclosure “IC” = NEMA 1 Indoor Enclosure with Clear Cover “O” = NEMA 3R Outdoor Enclosure “OC” = NEMA 3R Outdoor Enclosure with Clear Cover “IM” = NEMA 1 Indoor Metal Enclosure PART NO. TIMER VOLTAGE SWITCH AMPS 120, 60 Hz 208/240 v, 60 Hz 24 V, 60 Hz 277V,60Hz SPDT SPDT SPDT SPDT 21 21 21 21 SPDT SPDT SPDT 21 21 21 24-Hour GMX ST-“I”-120 GMX ST-“I”-240 GMX ST-“I”-24 GMX ST-“I”-277 TIMER VOLTAGE SWITCH AMPS 120, 60 Hz 208/240 V, 60 Hz 24 V, 60 Hz 277 V, 60 Hz SPDT SPDT SPDT SPDT 21 21 21 21 SPDT SPDT SPDT 21 21 21 7-Day 24-Hour, Battery Backup GMX QT-“I”-120 GMX QT-“I”-240 GMX QT-“I”-24 PART NO. 120, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz GMX SW-“I”-120 GMX SW-“I”-240 GMX SW-“I”-24 GMX SW-“I”-277 7-Day Battery Backup 367 GMX QW-“I”-120 GMX QW-“I”-240 GMX QW-“I”-24 120, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz TIMERS GRASSLIN MIL 72 SERIES (24-Hour, 7-Day) 24-HOUR TIME CONTROL TIMERS Time based control of lighting, ventilating, heating, cooling or other electrical loads in commercial and industrial applications. The MIL 72 time switches are available with a 24-hour or 7-day program dial with a SPDT switch (form “C” contact). The MIL 72A series is intended for surface mounting. The control is completely enclosed in a plastic housing and includes a terminal cover and sub-base for installation and hard wiring. The MIL 72E is intended for flush (panel) mounting. All units are supplied with a clear plastic cover. Features • Synchronous drive or quartz drive with battery backup • 21A SPDT switch • Captive trippers with interval as low as 15 minutes • With or without 3-way override • Real clock face • Surface, flush, or DIN rail mount Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24 SYNCHRONOUS WITHOUT OVERRIDE WITH 3-WAY OVERRIDE STuZ-24 STuZ-120 STuZ-240 STuZH-24 STuZH-120 STuZH-240 STuZH-277 QUARTZ 7-DAY CARRY-OVER**With 3-Way Override QTuZH-24 QTuZH-120 QTuZH-240 INPUT VOLTS 24 VAC 120 VAC 208/240 VAC 277 VAC SWITCH RATING 240 V MINIMUM ON/OFF TIME RES SPDT 21A SPDT 21A SPDT 21A SPDT 21A 15 min. 15 min. 15 min. 15 min. EVENT ON/OFF TIME ON 1/4 hr. ON 1/4 hr. ON 1/4 hr. ON 1/4 hr. 7-DAY TIME CONTROL MIL 72A — Surface Mount SYNCHRONOUS WITHOUT OVERRIDE WITHOUT 3-WAY OVERRIDE SWuZ-24 SWuZ-120 SWuZ-240 - SW7ZH-24 SWuZH-120 SWuZH-240 SWuZH-277 MIL 72E — Flush Mount QUARTZ 7-DAY CARRY-OVER**With 3-Way Override QWuZH-24 QWuZH-120 QWuZH-240 - INPUT VOLTS 24 VAC 120 VAC 208/240 VAC 277 VAC **Quartz units also operate on DC voltages down to 12 VDC. 368 SWITCH RATING 240 V MINIMUM ON/OFF TIME RES SPDT 21A SPDT 21A SPDT 21A SPDT 21A 2 hr. 2 hr. 2 hr. 2 hr. EVENT ON/OFF TIME ON 2 hr. ON 2 hr. ON 2 hr. ON 2 hr. TIMERS GRASSLIN GM digi SERIES (24-Hour, 7-Day) ONE Channel Electronic Time Controls In Enclosure GM Series: 30 Amp Electronic Time Controls GM20: 20 programs, 24 hr. or 7 day GM42: 42 programs, 7 day plus holiday program and automatic daylight time changeover. All GM20/42 models contain a manual temporary and continuous override. TIMERS 24 Hr./7 Day NEMA I Indoor Plastic Enclosure MODEL CODE INPUT VOLTAGE PROGRAMS GM1-digi20-I-120 GM1-digi20-I-240 GM1-digi20-I-277 GMD-digi20-I-120 GMD-digi20-I-240 GMD-digi20-I-277 GM1-digi42-I-120 GM1-digi42-I-240 GMD-digi42-I-120 GMD-digi42-I-240 120V 50/60 Hz 208/240V 50/60 Hz 277V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 277V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 20 20 20 20 20 20 42 42 42 42 SWITCH RATING 30A SPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT 30A DPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT 24 Hr/7 Day NEMA 3R Outdoor Plastic Enclosure MODEL CODE INPUT VOLTAGE PROGRAMS GM1-digi20-O-120 GM1-digi20-O-240 GM1-digi20-O-277 GMD-digi20-O-120 GMD-digi20-O-240 GMD-digi20-O-277 GM1-digi42-O-120 GM1-digi42-O-240 GMD-digi42-O-120 GMD-digi42-O-240 120V 50/60 Hz 208/240V 50/60 Hz 277V, 50/60 Hz 120V, 50/60 Hz 208/240V 50/60 Hz 277V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 20 20 20 20 20 20 42 42 42 42 SWITCH RATING 30A SPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT 30A DPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT 24 Hr/7 Day NEMA 1 Indoor Metal Enclosure MODEL CODE INPUT VOLTAGE PROGRAMS GM1-digi20-IM-120 GM1-digi20-IM-240 GM1-digi20-IM-277 GMD-digi20-IM-120 GMD-digi20-IM-240 GMD-digi20-IM-277 GM1-digi42-IM-120 GM1-digi42-IM-240 GMD-digi42-IM-120 GMD-digi42-IM-240 120V 50/60 Hz 208/240V 50/60 Hz 277V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 277V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 120V 50/60 Hz 208/240V 50/60 Hz 20 20 20 20 20 20 42 42 42 42 369 SWITCH RATING 30A SPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT 30A DPDT 30A SPDT 30A SPDT 30A DPDT 30A DPDT TIMERS GRASSLIN KM2 IN-WALL TIMER (24-Hour, 7-Day) 24-HOUR TIMERS • Captive trippers with 20-minute switching interval (2-1/3 hour for 7-day). • SPST 20A, 1 Hp @ 120 V switch. • Replaces standard wall switches. • Reliable synchronous timer motor. PART NO KM2 ST-CS KM2 STu-1G KM2 ST-2G KM2 STu-2G KM2 ST-3G KM2 ST-4G KM2 ST-2D KM2 ST-3D KM2 ST-2R KM2 STST-2G WALLPLATE CONFIGURATION SWITCH 1 Gang 1 Gang, 3 Way 2 Gang, Toggle 2 Gang, Toggle, 3 Way 3 Gang, Toggle 4 Gang, Toggle 2 Gang, Decorator 3 Gang, Decorator 2 Gang, Receptacle 2 Gang, Dual Timers SPST SPDT SPST SPDT SPST SPST SPST SPST SPST (2) SPST WALLPLATE CONFIGURATION SWITCH 1 Gang 1 Gang, 3 Way 2 Gang, Toggle 3 Gang, Toggle 4 Gang, Toggle 2 Gang, Decorator 3 Gang, Decorator 2 Gang, Receptacle 2 Gang, Dual Timers SPST SPDT SPST SPST SPST SPST SPST SPST (2) SPST 7-DAY PART NO KM2 SW-1G KM2 SWu-1G KM2 SW-2G KM2 SW-3G KM2 SW-4G KM2 SW-2D KM2 Sw-3D KM2 SW-2R KM2 SWSW-2G 370 TIMERS GRASSLIN GMX digi SERIES (24-Hour, 7-Day) • 16A @ 240V switch. • Indoor or outdoor enclosure. • Rechargeable battery backup with 1 week or more carryover. • Optional clear cover allows viewing timer clock face without opening cover. TIMERS Enclosure Options, Substitute the Following for “X”: “I” = NEMA 1 Indoor Enclosure “IC” = NEMA 1 Indoor Enclosure with Clear Cover “O” = NEMA 3R Outdoor Enclosure “OC” = NEMA 3R Outdoor Enclosure with Clear Cover “IM” = NEMA 1 Indoor Metal Enclosure NOTE: 6 V and 12 VDC Models Available PART NO GMX digi 20-“X”-120 GMX digi 20-“X”-240 GMX digi 20-“X”-24 GMX digi 20-“X”-277 GMX digi 42-“X”-120 GMX digi 42-“X”-240 GMX digi 42-“X”-24 GMX2 digi 42-“X”-120† GMX2 digi 42-“X”-240† GMX2 digi 42-“X”-24† TIMER VOLTAGE SWITCH AMPS 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz 277 V, 50/60 Hz 120 V, 50/60 Hz† 208/240 V, 50/60 Hz† 24 V, 50/60 Hz† 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz SPDT SPDT SPDT SPDT SPDT SPDT SPDT (2) SPDT (2) SPDT (2) SPDT 16 16 16 16 16 16 16 16 16 16 PROGRAMS 20 20 20 20 42 42 42 42 42 42 GRASSLIN digi 42/2 (24-Hour, 7-Day) Time based control of 2-circuit lighting, ventilating, heating, cooling or other electrical loads in commercial and industrial applications. The Digi 42/2 time switches are programmable for 24-hour or 7-day schedules as well as an "8th day" or holiday schedule. Each channel can operate independently or combined. • Two channel or double pole switching. • Automatic daylight time changeover. • 8th day HOLIDAY program. • 16 A, SPDT switching. PART NO Digi 42/2-120†† Digi 42/2-240† Digi 42/2-24† TIMER VOLTAGE MOUNTING* SETPOINT PROGRAMS 120 V, 50/60 Hz 240 V, 50/60 Hz 24 V, 50/60 Hz Flush or Surface Flush or Surface Flush or Surface 42 42 42 371 MAXIMUM WEEKLY ON/OFF RELAY OUTPUT GENERAL EVENTS PURPOSE RATING 294 (2) SPDT, 16 A, 240 VAC 294 (2) SPDT, 16 A, 250 VAC 294 (2) SPDT, 16 A, 250 VAC TIMERS GRASSLIN digi 20, digi 42 SERIES (24-Hour, 7-Day) • Automatic Daylight Time changeover with Digi 42 • Holiday program with Digi 42. • Rechargeable battery backup with 1 week or more carryover. • 16 amp, SPDT switching. ] C.E.C. CERTIFIED TITLE 24, PART 6 TIMERS ON ALL MODELS MARKED WITH “†” PART NO Digi 20A — 120 Digi 20A — 240 Digi 20A — 24 Digi 20A — 277 Digi 42A — 120† Digi 42A — 240† Digi 42A — 24† Digi 20E — 120 Digi 20E — 240 Digi 20E — 24 Digi 20E — 277 Digi 42E — 120† Digi 42E — 240† Digi 42E — 24† TIMER VOLTAGE MOUNTING* SETPOINT PROGRAMS 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz 277 V, 50/60 Hz 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz 277 V, 50/60 Hz 120 V, 50/60 Hz 208/240 V, 50/60 Hz 24 V, 50/60 Hz Surface or DIN Rail Surface or DIN Rail Surface or DIN Rail Surface or DIn Rail Surface or DIN Rail Surface or DIN Rail Surface or DIn Rail Flush Panel Flush Panel Flush Panel Flush Panel Flush Panel Flush Panel Flush Panel 20 20 20 20 42 42 42 20 20 20 20 42 42 42 MAXIMUM WEEKLY ON/OFF RELAY OUTPUT GENERAL EVENTS PURPOSE RATING 140 SPDT, 16 A, 250 V 140 SPDT, 15 A, 250 V 140 SPDT, 16 A, 250 V 140 SPDT, 16 A, 250 V 294 SPDT, 16 A, 250 V 294 SPDT, 16 A, 250 V 294 SPDT, 16 A, 250 V 140 SPDT, 16 A, 250 V 140 SDPT, 16 A, 250 V 140 SPDT, 16 A, 250 V 140 SPDT, 16 A, 250 V 294 SDPT, 15 A, 250 V 294 SDPT, 16 A, 250 V 294 SPDT, 16 A, 250 V GRASSLIN FM/1 SERIES (24-Hour, 7-Day) The FM/1 series modules are designed to be placed inside a machine control panel, circuit board, or other equipment. It offers up to 21A switching designed for control of heating, ventilating, air conditioning, refrigeration, lighting, security, circulating pumps, spas or any electrical load requiring 24-hour or 7-day scheduling. • Authentic clock face. • 21 A SPDT switch. • Captive Trippers. SWITCH OUTPUT PART NO FM/1 StuZ (synchronous) FM/1 SWuZ (synchronous) FM/1 QtuZ (quartz) FM/1 QWuZ (quartz) MINIMUM ON/OFF TIME SWITCH PROGRAM CARRY-OVER 15 minutes 2 hours 21 A Res. 21 A Res. 15 minutes 2 hours 21 A Res. 21 A Res. NOTES: 1. Available with 24 V, 120 V, 240 V, 277 VAC input. Type Rating No No PROGRAM ON/OFF EVERY 15 minutes 2 hours SPDT SPDT 21 A Res. 21 A Res. 7 day 7 day 15 minutes 2 hours SPDT SPDT 21 A Res. 21 A Res. 2. Quartz also available with 12 V, 30 V, 60 V, or 120 VDC input. 372 TIMERS GRASSLIN FM/1 digi 20-120 (24 Hour, 7-Day) GRASSLIN FM/1 digi 42-120 (24 Hour, 7-Day) • Automatic Spring/Fall Daylight Time changeover. • 42 programs, up to 294 events per week. • Holiday programming. • 16 Amp @ 277 V SPDT switching. • Rechargeable battery backup with carryover of over 2 weeks. PART NO FM/1 digi 20-240 FM/1 digi 20-24 FM/1 digi 20-277 FM/1 digi 42-120† FM/1 digi 42-240† FM/1 digi 42-24 INPUT VOLTAGE PROGRAMS SWITCH PROGRAM 240 V, 50/60 Hz 24 V, 50/60 Hz 277 V, 50/60 Hz 120 V, 50/60 Hz 240 V, 50/60 Hz 24 V, 50/60 Hz 20 20 20 42 42 42 24 hr./7 day 24 hr./7 day 24 hr./7 day 24 hr./7 day 24 hr./7 day 24 hr./7 day 373 MAX WEEKLY ON/OFF 140 140 140 294 294 294 HOLIDAY PROGRAM No No No Yes Yes Yes RESERVE CARRYOVER 1 week 1 week 1 week 2 weeks 2 weeks 2 weeks RELAY OUTPUT SPDT 16 A SPDT 16 A SPDT 16 A SPDT 16 A SPDT 16 A SPDT 16 A TIMERS The FM/1 digi 20 is a compact electronic 24 hour/ 7 day time switch module with heavy duty relay contacts for switching low or line voltage loads. Applicable for time of day control of pumps, fans, heaters, HVAC control circuits, lighting, machinery and many other types of commercial, industrial,and agricultural equipment. The FM/1 digi 20 features large keys with unique “circular pattern” for easy programming, an easy-to-read LCD display and capacitor backup to retain program memory during power outages. • 20 programs, up to 140 events per week. • Easy to program with large keys. • 16 Amp @ 277 V SPDT switching. • Capacitor backup with 5-day carryover. • Manual override. TIMERS GRASSLIN KLT SERIES COUNTDOWN/TWIST TIMERS SPRING WOUND INTERVAL/COUNTDOWN TIME SWITCH TIMERS • Timing ranges from 5 minutes to 12 hours. • SPST 20 A, 2 HP switch. • Decorator style dial plate fits both standard and decorator wallplates. • Aluminum wallplate available. • Fits in single or multigang wallboxes. • May be flush panel mounted. • Normally closed version (15 and 30 min. only) PART NO NO-HOLD MODELS WITH IVORYKNOB & PLATE HOLD MODELS WITH IVORYKNOB & PLATE KLT-5M KLT-15M KLT-15MC KLT-30M KLT-30MC KLT-60M KLT-2H KLT-4H KLT-6H KLT-12H KLT-5MH KLT-15MH — KLT-30MH — KLT-60MH KLT-2HH KLT-4HH KLT-6HH KLT-12HH TIME CYCLE 0-5 Minutes 0-15 Minutes 0-15 Minutes (Normally Closed) 0-30 Minutes 0-30 Minutes (Normally Closed) 0-60 Minutes 0-2 Hours 0-4 Hours 0-6 Hours 0-12 Hours Example: KLT-30M-W — Add “-W” to above for white knob and plate. Example: KLT-30MH-A — Add “-A” to above for aluminum plate and plastic knob. GRASSLIN ET 616 ELECTRONIC COUNTDOWN TIMER • Electronic version of the manual countdown timer. • Operates on 120 V or 277 VAC — No neutral wire required. • Mounts in standard wallbox. • Single button On/Off operation. • Backlighted LCD display. • Preset time countdown; 5, 15, 30, 60 minutes, 3, 6, 9, 12 hours. • Switch holds position during a power failure (on or off), restarts at preset time when power is restored. • UL and cUL listed. PART NO ET616 VOLTAGE SWITCH RATING 120 or 277 VAC, 50/60 Hz 1000 W (Tung.) @ 120 V;800 W (Bal.) @ 120 V;1500W (Tung.) @ 277 V;1200W (Bal.) @ 277 V 374 COUNTDOWN TIMING 5, 15, 30, 60 Min.3, 6, 9, 12 Hr. TIMERS GRASSLIN ET724 Electronic In-Wall Timer 24 Hour, 7 Day Replaces standard wall switch (toggle) to provide automatic control of outdoor or indoor lighting, fans, pumps, office machines, and other types of circuits. The unit can be programmed for 7-ON and 7-OFF events daily or weekly. AUTO and Manual Modes are clearly displayed along the time of day. The ET724 is designed to be mounted in a standard decorator plate for a sleek modern look. Features • LCD display • Flush mounted design • Non-volatile memory • Captive cover plate • UL Listed and CSA Approved SPECIFIERS GUIDE: Furnish and install a Grasslin model ET724 electronic in-wall 7 day time control. The timer shall fit into a standard 2-1/2” deep single or multigang wall box and decorator style wallplate. It shall not protrude from the wall more than 1/8” and have a captive cover plate over the programming keys. The unit shall be capable of switching a 20 amp ballast or general purpose load or 1 HP motor and have seven independently programmable events. The battery backup will be a rechargeable NiMh type that does not require replacement. SPECIFICATIONS Input: 120VAC, 60 Hz Switch Rating: 20A Ballast Switch Rating @ 120VAC, 20A Inductive Switch Rating @ 120VAC,2400W Resistive, 1HP Motor Operating Temperature: 32° to 122°F (0° to 50°C) Faceplate Color: White Timing Accuracy: Less Than 1% Deviation Wiring Connections: 6” Leadwires ORDERING DATA PART NO ET724 DESCRIPTION WALLPLATE CONFIGURATION SWITCH Electronic 24-hr./7-day (White) 1 Gang Decorator (Not Included) SPST 375 TIMERS • Sleek profile • Easy to program • Single push-button control • Mounts in standard wallbox • Built-in rechargeable battery never needs replacement TIMERS GRASSLIN T25/16 PLUG-IN TIMER Features • 24 hour electromechanical plug-in timer • Captive trippers • Programming resolution of 15 minutes • Easy to program • Manual override TIMERS Specifications: Input Voltage: 120VAC Switch Rating: 15A @ 125VAC Tungsten: 1250W, TV-4 1/3HP Polarized 2-conductor plug and receptacle ORDERING DATA PART NO SWITCH PROGRAM RESERVE PROGRAM ON/OFF EVERY 24 hour No 15 minutes T25 SHORTEST SWITCHING TIME 15 minutes GRASSLIN T35/16CS PLUG-IN TIMER Features • 24 hour electromechanical plug-in timer • Captive trippers • Programming resolution of 15 minutes • Easy to program • Manual override Specifications: Voltage: 110-120VAC Switch Rating: 15A Resistive Ambient Temperature Range: 14°F to 122°F Grounded 3-conductor plug and receptacle ORDERING DATA PART NO SWITCH PROGRAM RESERVE PROGRAM ON/OFF EVERY 24 hour No 15 minutes T35 SHORTEST SWITCHING TIME 15 minutes GRASSLIN T240 PLUG-IN TIMER Features • 24 hour electromechanical plug-in timer • Captive trippers • Programming resolution of 15 minutes • Heavy Duty 20A, 4800W • Manual override Specifications: Voltage: 240VAC, 60Hz Switch Rating: 20A Resistive Ambient Temperature Range: 14°F to 122°F Grounded 3-conductor plug and receptacle ORDERING DATA PART NO T240 SWITCH PROGRAM RESERVE PROGRAM ON/OFF EVERY 24 hour No 15 minutes 376 SHORTEST SWITCHING TIME 15 minutes
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 13 Producer : GPL Ghostscript 8.15 Create Date : 2011:03:26 01:13:12 Modify Date : 2011:03:26 01:13:12 Title : C:\Documents and Settings\Gen...op\GRASSLIN-series-timers.PDF Creator : Adobe Acrobat 8.0 Author : Gene HaynesEXIF Metadata provided by EXIF.tools