Grundfos JPF JPS JDF Shallow Deep Well Convertible Jet Pumps 60Hz Lenntech 4 Brochure

User Manual: JDF-4

Open the PDF directly: View PDF PDF.
Page Count: 22

DownloadGrundfos-JPF-JPS-JDF-Shallow-Deep-Well-Convertible-Jet-pumps-60Hz-Lenntech JDF-4 Brochure
Open PDF In BrowserView PDF
Lenntech

info@lenntech.com

GRUNDFOS PRODUCT GUIDE

www.lenntech.com

JPF, JPS, JDF
Shallow Well, Deep Well and
Convertible Jet Pumps
60 Hz

1

Contents

Page

Mission

3

General data
Performance range
Product range
Applications
Pump
Motor
Pumped Liquid
Agency Approvals
Mounting Position
Electrical Data
Materials of Construction

4
5
6
6
6
6
6
6
7
8

Technical data
JPF 2A, 3A, 4A, 41A
Dimensions and Weights
Performance Chart
Performance Curves
JPF 5A, 7A Convertibles
Dimensions and Weights
Conversion Instructions
Performance Chart
Performance Curves
Deep Well Performance Chart
JPS 2A, 4A
Dimensions and Weights
Performance Chart
Performance Curves
JDF 2A, 4A
Dimensions and Weights
Ejector Dimensions
Performance Chart
JPF Pump Package
Dimensions and Weights
Performance Chart
JPS Pump Package
Dimensions and Weights
Performance Chart

2

11
11
11
12
13
13
13
14
14
15
16
16
16
17
18
18
18
19
20
20
20
21
21
21

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

�������
Mission

���������

����������������������������������������������������������
�������������������������������������������������������
������������������������������������������������

��������������������

������������������

�����������������

��������������

�����������������������

�������������������������

� ������������������������������������������������������������������������������������
� �����������������������������
� ��������������������������������������������������������������������������������
� ����������������������������
� ������������������������������������������������������
� ������������������������������������������������������������
� ������������������������������������������������������������������������
�����������������������������������������

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

3�

General data

Performance range



4

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

General data

Product range
Model

JPF 2-A

JPF 3-A

JPF 4-A

JPF 41-A JPF 5-A

Flow range (gpm)

0-13

0-12.5

0-16

0-21

JPF 7-A

JPS 2-A

JPS 4-A

JDF 2-A

JDF 4

0-22

0-35

0-17

0-29

0-10

0-14

Max. pump head H(ft)

135

170

172

185

200

200

140

155

145

167

Max. working pressure (psi)

87

87

87

87

110

110

110

110

87

87

Motor power (hp), Nominal

1/3

1/2

3/4

1

1.5

2

1/2

1

1/2

3/4

26

26

30-50

30-50

30-50

30-50

Maximum Fluid Temperature range
Maximum lift, Ft

14°F to 104°F (-10 to 40°C)
26

26

26

26

Maximum Ambient Temp
Factory Pressure -Switch setting (PSI)

34°F to 104°F (1 to 40°C)
20-40

30-50

Storage Temp
Relative Humidity
Maximum Starts per hour

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

30-50

50-70

50-70

50-70

14°F to 104°F (-10 to 40°C)
95%
20

5

General data

Applications

Motors

Shallow well, Deep well and Convertible pump
applications. Grundfos jet pumps are self-priming
centrifugal pumps suitable for domestic water supply
systems, light agricultural and industrial water
transfer applications

All jet pump motors are totally enclosed and fancooled design for quiet operation and superior protection in harsh environments. Stainless steel motor shaft
offers excellent corrosion resistance. Double, oversized
greased ball bearings are maintenance-free sealed for
life. All motors have built-in thermal overload protection and are capacitor-run, with no switches to fail.
Drive end motor bearing protected by durable lip seal.
Motor insulation class F. NEMA 3R enclosure rating on
motor terminal box.

Pumps
JPF2A, JPF3A, JPF4A, JPF41A Pumps:
Rugged cast iron construction, single-stage shallow
well centrifugal pumps. End suction, top discharge
arrangement and Technopolymer impeller. Pump
has built-in ejector complete with clean out port to
clear blockages from nozzle. Convenient priming
plug for ease of priming and air elimination. CeramicCarbon bellows mechanical seal ensures trouble-free
operation.
JPF5A & JPF7A Pumps:
Rugged cast iron construction, multistage convertible
centrifugal pumps. End suction, top discharge
arrangement with detachable ejector assembly for
deep well applications and Technopolymer impellers.
Pump complete with clean out port to clear blockages
from nozzle. Convenient priming plug for ease of
priming and air elimination. Ceramic-Carbon bellows
mechanical seal ensures trouble-free operation.

Pumped Liquid
Only use on clean, non-viscous, non-aggressive, nonexplosive liquids. Pump not to be used on pool water
applications or hydrocarbon transfer (i.e. diesel, gasoline, etc).

Agency Approvals:
CSA -Std C22.2 No 108, No 77-95.

Mounting Position:
Shaft in horizontal position only for all pumps.

JDF2A & JDF4A Pumps:
Rugged cast iron construction, single-stage deep
well centrifugal pumps. End suction, top discharge
arrangement and Technopolymer impeller. Pump
has separate deep well port for connection to Deep
Well ejector kit. Convenient priming plug for ease of
priming and air elimination. Ceramic-Carbon bellows
mechanical seal ensures trouble-free operation.
JPS2A & JPS4A Pumps:
Corrosion resistant stainless steel construction, single
stage shallow well centrifugal pumps. End suction, top
discharge arrangement and Technopolymer impeller.
Ceramic-Carbon bellows mechanical seal ensures
trouble-free operation.

6

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

General data

Electrical Data:
Electrical Data
Model

Voltage
60 Hz

kW
Maximum

hp
Nominal

S.F.

I
Amps

Capacitor
µF

JPF2A

115

0.44

1/3

1.8

6

40

JPF2A

230

0.44

1/3

1.8

3

10

JPF3A

115

0.59

1/2

1.6

7.5

20

JPF3A

230

0.59

1/2

1.6

3.8

12.5

JPF4A

115

0.75

3/4

1.3

10

64

JPF4A

230

0.75

3/4

1.3

5

16

JPF41A

115

1.31

1

1.4

12

80

JPF41A

230

1.31

1

1.4

A

20

JPF5A

230

1.1

1.5

1.5

8

31.5

JPF7A

230

1.85

2

1.3

11

40

JPS2A

115

0.88

1/2

1.6

7.6

50

JPS2A

230

0.82

1/2

1.6

3.7

12.5

JPS4A

115

1.6

1

2.0

13.6

80

JPS4A

230

1.53

1

2.0

7

20

JDF2A

115

0.6

1/2

1.6

7

50

JDF 2A

230

0.6

1/2

1.6

3.4

12.5

JDF4A

115

0.75

3/4

1.3

8

64

FDF 4A

230

0.75

3/4

1.3

4

16

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

7

General data

JPF 2A, 3A, 4A, 41A Shallow Well

JPF 5A, 7A Convertible

Materials: JPF 2A, 3A, 4A, 41A
Shallow Well

Materials: JPF 5A, 7A
Convertible

Descriptions

Material

Descriptions

Material

Motor Stool

Cast Iron

Motor Stool

Cast Iron

Shaft Seal

Carbon/Ceramic/NBR

Shaft Seal

Carbon/Ceramic/NBR

O-Rings & Gaskets

NBR

Motor Shaft

Stainless Steel

Base Plate

Cast Iron

O-Rings & Gaskets

NBR

Pump Housing

Cast Iron

Base Plate

Cast Iron

Impeller

Technopolymer

Pump housing

Cast Iron

Tubing

Polyethylene

Impellers

Technopolymer

Seal plate

Noryl©

Tubing

Polyethylene

Ejector/Guide Vane

Noryl©

Seal plate

Noryl©

Ejector/Guide Vane

Noryl©

Note: Noryl© is a registered trademark of General Electric Company
Note: Noryl© is a registered trademark of General Electric Company

8

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

General data

JPS 2A, 4A

JDF 2A, 4A

Materials: JPS 2A, 4A

Materials: JDF 2A, 4A

Descriptions

Material

Descriptions

Material

Motor Stool

Cast Iron

Motor Stool

Cast Iron

Shaft Seal

Carbon/Ceramic/NBR

Shaft Seal

Ceramic/Ceramic/NBR

O-Rings & Gaskets

NBR

O-Rings & Gaskets

NBR

Base Plate

Steel

Base Plate

Cast Iron

Pump housing

Stainless Steel AISI 304

Pump housing

Cast Iron

Impeller

Technopolymer A

Impeller

Technopolymer

Tubing

Polyethylene

Tubing

Polyethylene

Seal plate

Stainless Steel AISI 304

Seal plate

Noryl©

Ejector/Guide Vane

Technopolymer A

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

Note: Noryl© is a registered trademark of General Electric Company

9

General data

JPF Pump package*

JPS Pump package*

Cast Iron

Stainless Steel

*Only available in Canada

*Only available in Canada

Features and Benefits
Assembled jet-pump and tank package. Available with rugged cast iron pump or corrosion-resistant stainless
steel pump mounted on a stainless steel, 6 gallon (24 Litre) diaphram tank.
Package comes complete with pressure switch, gauge, hose and fittings, ready to go.

Materials: JPF Pump Package

Materials: JPS Pump Package

Descriptions

Material

Descriptions

Material

Motor Stool

Cast Iron

Motor Stool

Cast Iron

Shaft Seal

Carbon/Ceramic/NBR

Shaft Seal

Carbon/Ceramic/NBR

O-Rings and Gaskets

NBR

O-Rings and Gaskets

NBR

Base Plate

Cast Iron

Base Plate

Steel

Pump Housing

Cast Iron

Pump Housing

Stainless Steel AISI304

Impeller

Technopolymer

Impeller

Technopolymer A

Tubing

Polyethylene

Tubing

Polyethylene

Seal Plate

Noryl©

Seal Plate

Stainless Steel AISI304

Ejector/Guide Vane

Noryl©

Ejector/Guide Vane

Technopolymer A

Tank

Stainless Steel AISI304

Tank

Stainless Steel AISI304

Note: Noryl© is a registered trademark of General Electric Company

10

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

Technical data

JPF 2A, 3A, 4A, 41A

Dimensional Drawings

Dimensions and Weights
Motor Data

Pump
Type

JPF2A
JPF3A
JPF4A
JPF41A

HP

S.F.

PH

Volts

1/3
1/2
3/4
1

1.8
1.6
1.3
1.4

1
1
1
1

115 or 230
115 or 230
115 or 230
115 or 230

D1
Suction
NPT

D2
Disch.
NPT

1’’
1’’
1’’
1’’

1’’
1’’’
1’’
1’’

Dimensions (inches)

A

B

B1

C

E

F

G

H

H1

IØ

16.2
16.2
17.3
17.3

7.1
7.1
7.1
7.1

9.1
9.1
9.1
9.1

5.5
5.5
5.5
5.5

8.9
8.9
9.2
9.2

0.6
0.6
0.6
0.6

5.5
5.5
5.5
5.5

8.9
8.5
8.9
8.9

6.0
6.0
6.0
6.0

0.38
0.38
0.38
0.38

50

55

Ship
Wt.
(lbs)

Ship
Vol.
(Cu
Ft.)

35
36
41
43

1.5
1.5
1.5
1.5

Shallow Well Performance Chart
Depth to Water
Model

HP

Discharge Pressure (PSI)
20

30

11
10
9
7
5
12
10.5
9
7.5
5
15
13
11
9
6
21
19
16
13.5
10

7
7
7
6
4
11
10
8.5
7
5
14
12.5
11
9
6
20.5
18.5
16
13.5
10

35

40

45

Shutoff (PSI)

Pressure Switch Settings
(PSI)

Capacities (GPM)*

JPF2A

1/3

JPF3A

1/2

JPF4A

3/4

JPF41A

1

5
10
15
20
25
5
10
15
20
25
5
10
15
20
25
5
10
15
20
25

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

6
6
6
5
3
11
10
8
7
5
14
12.5
10
9
6
20
18
16
13.5
10

4
4
4
4
2
10
9.5
8
7
5
13
12
10
8.5
6
20
18
15.5
13
9.5

3
3
3
3
1
7
7
7
6.5
4.5
10
10
10
8
5
20
17.5
15
13
9

2
2
2
2
6
6
6
6
4
8.5
8.5
8
7
5
19
17.5
15
12.5
9

4
4
4
4
4
6
6
6
6
5
17.5
17
14.5
12
8.5

58
56.5
54
51.5
49
73.5
71
68.5
66
63.5
75.5
73
70.5
68
65.5
86.5
84
81.5
79
76.5

20-40

30-50

30-50

50-70

11

Performance curves

JPF 2A, 3A, 4A, 41A

Shallow Well Performance Curves

12

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

Technical data

JPF 5A, 7A Convertibles

Dimensional Drawings

Shallow Well

Deep Well

Dimensions and Weights
Motor Data

Pump
Type

JPF5A
JPF7A

HP

S.F. PH Volts

1.5
2

1.5
1.3

1
1

230
230

D1
D2
D3
Suction Disch. ReNPT
NPT turn
NPT
1-1/4’’
1-1/4’’

1’’
1’’’

1’’
1’’

Dimensions (inches)

A1

A2

B

B1

C1

C2

E1

E2

F

G

H

H1

H2

22.0 15.3 8.3 11.0 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3
25.6 19.9 8.3 12.4 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3

H3

IØ

Ship Ship
Wt. Vol.
(lbs) (Cu
Ft.)

2.1 0.44 70
2.1 0.44 73

1.9
2.5

Conversion Instructions
from Shallow Well to DeepWell
Remove bolts and detach ejector nose from
convertible jet pump. Connect suction (D1) and
pressure (D3) port to deep well ejector.

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

13

Technical data

JPF 5A, 7A Convertibles

Shallow Well Performance Chart
Model

JPF5A

JPF7A

HP

Depth to Water

20

30

5
10
15
20
25
5
10
15
20
25

21
19
16
13.5

20.5
18.5
16
13.5
10
34
28
24
20
15.5

1-1/2

2

34
28.5
24
20

Discharge Pressure (PSI)
35
40
45
50
Capacities (GPM)*
20
20
20
19
18
18
17.5
17.5
16
15.5
15
15
13.5
13
13
12.5
10
9.5
9
9
33.5
33
32.5
30
28
28
27.5
27
23.5
23.5
23
22.5
19.5
19.5
19.5
19
15.5
15.5
15
15

55

Shut-off (PSI)

17.5
17
14.5
12
8.5
27
26
22
19
15

86.5
84
81.5
79
76.5
88
85.7
83
80
77.8

Pressure Switch
Settings (PSI)

50-70

50-70

Performance Curves

14

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

JPF 5A, 7A Convertibles

Technical data

Deep Well Performance Chart
Discharge Pressure (psig)
Model

Ejector Type

Depth to water (feet)
30

40

50

60

70

80

90

100

449
373
306
244
190

406
333
271
214
162

358
293
234
177
137

302
248
190
125
113

560
430
313
201
112
478
383
318
255
203

482
352
240
143
371
306
247
195
148

310
262
215
157
116

120

140

Capacities USgph*

E20

JPF5A

E25

E30

E20

JPF7A

E25

E30

45
50
60
65
75
50
60
65
75
80
50
60
65
75
80
50
60
65
75
80
50
60
65
75
90
65
75
80
90
95

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

896
727
575
365
177

1054
854
664
469
253

794
615
438
247
63

945
755
589
365
156

682
505
320
130

586
404
220

606
484
362
247
151

534
411
323
190
102

859
633
430
221

703
510
305
102

716
586
456
331
221

635
505
379
260
161

411
341
281
226
177

15

Technical data

JPS 2A, 4A

Dimensional Drawings

Dimensions and Weights

HP
JPS2A
JPS4A

D1
D2
Suction Disch.
NPT
NPT

Motor Data

Pump
Type

S.F.

PH

Volts

1
1

115 or 230
115 or 230

1/2 1.5
1 1.36

1’’
1’’

1’’
1’’’

Dimensions (inches)

A

B

B1

C

E

F

G

H1

H2

L

IØ

14.8
15.6

7.5
7.5

9.3
9.3

3.7
3.7

4.8
4.8

7.1
7.1

4.3
4.3

9.1
9.1

7.0
7.0

0.83
0.83

0.42
0.42

Ship
Wt.
(lbs)

Ship
Vol.
(Cu
Ft.)

24
31

1.5
1.5

Shallow Well Performance Chart
Depth to Water
Model

HP

Discharge Pressure (PSI)
20

30

35

40

45

50

55

4
3
2
1

2
1

10
9
8
7
6

7
6
5
4
3

Shutoff (PSI)

Pressure Switch Settings
(PSI)

Capacities (GPM)*

JPS2A

JPS4A

16

1/2

1

5
10
15
20
25
5
10
15
20
25

15
14
13
10
8
30
26
22
18
14

13
12
11
10
8
27
23
21
17
13

11
10
9
8
7
22
21
20
16
13

8
7
6
5
4
17
16
15
14
12

6
5
4
3
2
14
13
12
11
11

62
59.5
57
54.5
52
68
65.5
63
60.5
58

30-50

30-50

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

Performance curves

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

JPS 2A, 4A

17

Technical data

JDF 2A, 4A

Dimensional sketches

Dimensions and Weights
Motor Data

Pump
Type

JDF2A
JDF4A

D1
D2
D3
Suction Disch. Return
NPT
NPT NPT

HP

S.F.

PH

Volts

1/2
3/4

1.6
1.3

1
1

115 or 230
115 or 230

1.25’’
1.25’’

1’’
1’’’

1’’
1’’

Dimensions (inches)

A

B

B1

C

E

IØ

G

H

H1

H2

15.2
15.2

7.1
7.1

9.1
9.1

3.5
3.5

8.0
8.0

0.38
0.38

5.5
5.5

8.9
8.9

1.9
1.9

3.6
3.6

Ship
Wt.
(lbs)

Ship
Vol.
(Cu
Ft.)

36
37

1.5
1.5

Ejector Dimensions
AE
3.8
3.8

18

HE1
11.6
11.6

HE2
5.63
5.63

X
1’’ NPT
1’’NPT

Y
Z
1’’NPT 1.25’’NPT
1’’NPT 1.25’’NPT

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

JDF 2A, 4A

Technical data

Performance Chart
Discharge Pressure (psig)
Model

Ejector Type

Depth to water (feet)
30

40

50

60

70

100

120

Capacities USgph*

E20

JDF2A

E25

E30

E20

JDF4A

E25

E30

20
30
35
45
SHUTOFF
20
30
35
45
SHUTOFF
20
30
35
45
50
SHUTOFF
20
30
35
45
SHUTOFF
20
30
35
45
SHUTOFF
30
35
45
50
SHUTOFF

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

625
350
230
60
49
500
355
290
175
125
63

800
525
400
160
53

510
270
155

395
175
70

44
430
295
230
125
75
58

42
375
240
175
80
40
55

670
410
280
65
49
360
320
190
135
72

525
290
175
45
325
260
140
95
65

265
200
100
65
60

210
160
75
35
57

19

Performance curves

JPF Pump Package*
*Only available in Canada

Dimensional Drawings

Dimensions and Weights
Motor Data

Pump Type

JPF3A

HP

S.F.

PH

Volts

1/2

1

1

115 or 230

D1
Suction
NPT

D2
Disch.
NPT

1’’

1’’’

Dimensions (inches)

A

B

B1

C

D

E

F

G

H1

1.2

11.9

9.1

5.5

9.1

7.1

15.2

11.9

6.0

Ship
Wt.
(lbs)

Ship
Vol.
(Cu
Ft.)

7.0

5.0

Shallow Well Performance Chart
Depth to Water
Model

HP

Discharge Pressure (PSI)
20

30

12
10.5
9
7.5
5

11
10
8.5
7
5

35

40

45

50

55

6
6
6
6
4

4
4
4
4
4

Shutoff (PSI)

Pressure Switch Settings
(PSI)

73.5
71
68.5
66
63.5

30-50

Capacities (GPM)*

JPF3A

20

1/2

5
10
15
20
25

11
10
8
7
5

10
9.5
8
7
5

7
7
7
6.5
4.5

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

JPS Pump Package*

Technical data

*Only available in Canada

Dimensional Drawings

Dimensions and Weights

JPS2A

D1
D2
Suction Disch.
NPT
NPT

Motor Data

Pump
Type
HP

S.F.

PH

Volts

1/2

1.5

1

115 or 230

1’’

1’’

Dimensions (inches)

A

B

B1

C

E

F

G

H1

H2

IØ

14.8

11.9

9.3

3.7

7.1

15.2

11.9

8.5

6.0

0.38

Ship
Wt.
(lbs)

Ship Vol.
(Cu Ft.)

45.0

5.0

Shallow Well Performance Chart
Depth to Water
Model

HP

Discharge Pressure (PSI)
20

30

15
14
13
10
8

13
12
11
10
8

35

40

45

50

55

4
3
2
1

2
1

Shutoff (PSI)

Pressure Switch Settings
(PSI)

62
59.5
57
54.5
52

30-50

Capacities (GPM)*

JPS2A

1/2

5
10
15
20
25

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89

11
10
9
8
7

8
7
6
5
4

6
5
4
3
2

21

Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

L-JP-PG-001

5/03

Subject to alterations.

PRINTED IN USA

U.S.A.
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: (913) 227-3400
Telefax: (913) 227-3500

Lenntech

info@lenntech.com
22

www.grundfos.com
www.lenntech.com

Canada
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario
L6H 6C9
Phone: (905) 829-9533
Telefax: (905) 829-9512

Mexico
Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L. Mexico
Phone: 011-52-81-8144 4000
Telefax: 011-52-81-8144 4010



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Create Date                     : 2003:03:25 09:38:55Z
Modify Date                     : 2013:03:14 13:43:44+01:00
Metadata Date                   : 2013:03:14 13:43:44+01:00
Creator Tool                    : Adobe InDesign 2.0.1(Infix Pro)
Document ID                     : adobe:docid:indd:e3037721-5ed7-11d7-9427-daac15dea395
Version ID                      : 1
Rendition Class                 : proof:pdf
Instance ID                     : uuid:ce14d899-454a-456b-b059-36d66ce43374
Rendition Of Document ID        : adobe:docid:indd:e3037721-5ed7-11d7-9427-daac15dea395
Rendition Of Version ID         : 1
Rendition Of Rendition Class    : default
Format                          : application/pdf
Title                           : Grundfos-JPF-JPS-JDF-Shallow-Deep-Well-Convertible-Jet-pumps-60Hz-Lenntech
Creator                         : Grundfos-Lenntech
Subject                         : Grundfos-JPF-JPS-JDF-Shallow-Deep-Well-Convertible-Jet-pumps-60Hz-Lenntech
Keywords                        : Grundfos-JPF-JPS-JDF-Shallow-Deep-Well-Convertible-Jet-pumps-60Hz-Lenntech
ICN App Name                    : Infix Pro
ICN App Platform                : Windows
ICN App Version                 : 5.28
Page Count                      : 22
Author                          : Grundfos-Lenntech
EXIF Metadata provided by EXIF.tools

Navigation menu