Grundfos JPF JPS JDF Shallow Deep Well Convertible Jet Pumps 60Hz Lenntech 4 Brochure

User Manual: JDF-4

Open the PDF directly: View PDF PDF.
Page Count: 22

1
GRUNDFOS PRODUCT GUIDE
JPF, JPS, JDF
Shallow Well, Deep Well and
Convertible Jet Pumps
60 Hz
Lenntech
info@lenntech.com
www.lenntech.com
2
3
Contents
Page
Mission 3
General data
Performance range 4
Product range 5
Applications 6
Pump 6
Motor 6
Pumped Liquid 6
Agency Approvals 6
Mounting Position 6
Electrical Data 7
Materials of Construction 8
Technical data
JPF 2A, 3A, 4A, 41A 11
Dimensions and Weights 11
Performance Chart 11
Performance Curves 12
JPF 5A, 7A Convertibles 13
Dimensions and Weights 13
Conversion Instructions 13
Performance Chart 14
Performance Curves 14
Deep Well Performance Chart 15
JPS 2A, 4A 16
Dimensions and Weights 16
Performance Chart 16
Performance Curves 17
JDF 2A, 4A 18
Dimensions and Weights 18
Ejector Dimensions 18
Performance Chart 19
JPF Pump Package 20
Dimensions and Weights 20
Performance Chart 20
JPS Pump Package 21
Dimensions and Weights 21
Performance Chart 21
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
2
3
Mission



 
  



 
 
 
 
 
 
 

info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
4
5
Performance range
General data
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
4
5
General data
Product range
Model JPF 2-A JPF 3-A JPF 4-A JPF 41-A JPF 5-A JPF 7-A JPS 2-A JPS 4-A JDF 2-A JDF 4
Flow range (gpm) 0-13 0-12.5 0-16 0-21 0-22 0-35 0-17 0-29 0-10 0-14
Max. pump head H(ft) 135 170 172 185 200 200 140 155 145 167
Max. working pressure (psi) 87 87 87 87 110 110 110 110 87 87
Motor power (hp), Nominal 1/3 1/2 3/4 1 1.5 2 1/2 1 1/2 3/4
Maximum Fluid Temperature range 14°F to 104°F (-10 to 40°C)
Maximum lift, Ft 26 26 26 26 26 26
Maximum Ambient Temp 34°F to 104°F (1 to 40°C)
Factory Pressure -Switch setting (PSI) 20-40 30-50 30-50 50-70 50-70 50-70 30-50 30-50 30-50 30-50
Storage Temp 14°F to 104°F (-10 to 40°C)
Relative Humidity 95%
Maximum Starts per hour 20
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
6
7
General data
Applications
Shallow well, Deep well and Convertible pump
applications. Grundfos jet pumps are self-priming
centrifugal pumps suitable for domestic water supply
systems, light agricultural and industrial water
transfer applications
Pumps
JPF2A, JPF3A, JPF4A, JPF41A Pumps:
Rugged cast iron construction, single-stage shallow
well centrifugal pumps. End suction, top discharge
arrangement and Technopolymer impeller. Pump
has built-in ejector complete with clean out port to
clear blockages from nozzle. Convenient priming
plug for ease of priming and air elimination. Ceramic-
Carbon bellows mechanical seal ensures trouble-free
operation.
JPF5A & JPF7A Pumps:
Rugged cast iron construction, multistage convertible
centrifugal pumps. End suction, top discharge
arrangement with detachable ejector assembly for
deep well applications and Technopolymer impellers.
Pump complete with clean out port to clear blockages
from nozzle. Convenient priming plug for ease of
priming and air elimination. Ceramic-Carbon bellows
mechanical seal ensures trouble-free operation.
JDF2A & JDF4A Pumps:
Rugged cast iron construction, single-stage deep
well centrifugal pumps. End suction, top discharge
arrangement and Technopolymer impeller. Pump
has separate deep well port for connection to Deep
Well ejector kit. Convenient priming plug for ease of
priming and air elimination. Ceramic-Carbon bellows
mechanical seal ensures trouble-free operation.
JPS2A & JPS4A Pumps:
Corrosion resistant stainless steel construction, single
stage shallow well centrifugal pumps. End suction, top
discharge arrangement and Technopolymer impeller.
Ceramic-Carbon bellows mechanical seal ensures
trouble-free operation.
Motors
All jet pump motors are totally enclosed and fan-
cooled design for quiet operation and superior protec-
tion in harsh environments. Stainless steel motor shaft
offers excellent corrosion resistance. Double, oversized
greased ball bearings are maintenance-free sealed for
life. All motors have built-in thermal overload protec-
tion and are capacitor-run, with no switches to fail.
Drive end motor bearing protected by durable lip seal.
Motor insulation class F. NEMA 3R enclosure rating on
motor terminal box.
Pumped Liquid
Only use on clean, non-viscous, non-aggressive, non-
explosive liquids. Pump not to be used on pool water
applications or hydrocarbon transfer (i.e. diesel, gaso-
line, etc).
Agency Approvals:
CSA -Std C22.2 No 108, No 77-95.
Mounting Position:
Shaft in horizontal position only for all pumps.
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
6
7
General data
Electrical Data:
Model
Electrical Data
Voltage
60 Hz
kW
Maximum
hp
Nominal
S.F. I
Amps
Capacitor
µF
JPF2A 115 0.44 1/3 1.8 6 40
JPF2A 230 0.44 1/3 1.8 3 10
JPF3A 115 0.59 1/2 1.6 7.5 20
JPF3A 230 0.59 1/2 1.6 3.8 12.5
JPF4A 115 0.75 3/4 1.3 10 64
JPF4A 230 0.75 3/4 1.3 5 16
JPF41A 115 1.31 1 1.4 12 80
JPF41A 230 1.31 1 1.4 A 20
JPF5A 230 1.1 1.5 1.5 8 31.5
JPF7A 230 1.85 2 1.3 11 40
JPS2A 115 0.88 1/2 1.6 7.6 50
JPS2A 230 0.82 1/2 1.6 3.7 12.5
JPS4A 115 1.6 1 2.0 13.6 80
JPS4A 230 1.53 1 2.0 7 20
JDF2A 115 0.6 1/2 1.6 7 50
JDF 2A 230 0.6 1/2 1.6 3.4 12.5
JDF4A 115 0.75 3/4 1.3 8 64
FDF 4A 230 0.75 3/4 1.3 4 16
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
8
9
General data
JPF 2A, 3A, 4A, 41A Shallow Well
Materials: JPF 2A, 3A, 4A, 41A
Shallow Well
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump Housing Cast Iron
Impeller Technopolymer
Tubing Polyethylene
Seal plate Noryl©
Ejector/Guide Vane Noryl©
Note: Noryl© is a registered trademark of General Electric Company
JPF 5A, 7A Convertible
Materials: JPF 5A, 7A
Convertible
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
Motor Shaft Stainless Steel
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump housing Cast Iron
Impellers Technopolymer
Tubing Polyethylene
Seal plate Noryl©
Ejector/Guide Vane Noryl©
Note: Noryl© is a registered trademark of General Electric Company
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
8
9
General data
JPS 2A, 4A
Materials: JPS 2A, 4A
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Steel
Pump housing Stainless Steel AISI 304
Impeller Technopolymer A
Tubing Polyethylene
Seal plate Stainless Steel AISI 304
Ejector/Guide Vane Technopolymer A
JDF 2A, 4A
Materials: JDF 2A, 4A
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Ceramic/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump housing Cast Iron
Impeller Technopolymer
Tubing Polyethylene
Seal plate Noryl©
Note: Noryl© is a registered trademark of General Electric Company
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
10
11
Features and Benets
Assembled jet-pump and tank package. Available with rugged cast iron pump or corrosion-resistant stainless
steel pump mounted on a stainless steel, 6 gallon (24 Litre) diaphram tank.
Package comes complete with pressure switch, gauge, hose and ttings, ready to go.
General data
JPF Pump package*
Cast Iron
*Only available in Canada
Materials: JPF Pump Package
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings and Gaskets NBR
Base Plate Cast Iron
Pump Housing Cast Iron
Impeller Technopolymer
Tubing Polyethylene
Seal Plate Noryl©
Ejector/Guide Vane Noryl©
Tank Stainless Steel AISI304
Note: Noryl© is a registered trademark of General Electric Company
JPS Pump package*
Stainless Steel
*Only available in Canada
Materials: JPS Pump Package
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings and Gaskets NBR
Base Plate Steel
Pump Housing Stainless Steel AISI304
Impeller Technopolymer A
Tubing Polyethylene
Seal Plate Stainless Steel AISI304
Ejector/Guide Vane Technopolymer A
Tank Stainless Steel AISI304
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
10
11
Dimensional Drawings
Dimensions and Weights
Pump
Type
Motor Data D1
Suction
NPT
D2
Disch.
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship
Vol.
(Cu
Ft.)
HP S.F. PH Volts A B B1 C E F G H H1
JPF2A 1/3 1.8 1 115 or 230 1’ 1’’ 16.2 7.1 9.1 5.5 8.9 0.6 5.5 8.9 6.0 0.38 35 1.5
JPF3A 1/2 1.6 1 115 or 230 1’ 1’ 16.2 7.1 9.1 5.5 8.9 0.6 5.5 8.5 6.0 0.38 36 1.5
JPF4A 3/4 1.3 1 115 or 230 1’ 1’’ 17.3 7.1 9.1 5.5 9.2 0.6 5.5 8.9 6.0 0.38 41 1.5
JPF41A 1 1.4 1 115 or 230 1’’ 1’ 17.3 7.1 9.1 5.5 9.2 0.6 5.5 8.9 6.0 0.38 43 1.5
Shallow Well Performance Chart
Model HP
Depth to Water Discharge Pressure (PSI) Shut-
off (PSI)
Pressure Switch Settings
(PSI)
20 30 35 40 45 50 55
Capacities (GPM)*
JPF2A 1/3
5 11 7 6 4 3 2 58
20-40
10 10 7 6 4 3 2 56.5
15 9 7 6 4 3 2 54
20 7 6 5 4 3 2 51.5
25 5 4 3 2 1 49
JPF3A 1/2
5 12 11 11 10 7 6 4 73.5
30-50
10 10.5 10 10 9.5 7 6 4 71
15 9 8.5 8 8 7 6 4 68.5
20 7.5 7 7 7 6.5 6 4 66
25 5 5 5 5 4.5 4 4 63.5
JPF4A 3/4
5 15 14 14 13 10 8.5 6 75.5
30-50
10 13 12.5 12.5 12 10 8.5 6 73
15 11 11 10 10 10 8 6 70.5
20 9 9 9 8.5 8 7 6 68
25 6 6 6 6 5 5 5 65.5
JPF41A 1
5 21 20.5 20 20 20 19 17.5 86.5
50-70
10 19 18.5 18 18 17.5 17.5 17 84
15 16 16 16 15.5 15 15 14.5 81.5
20 13.5 13.5 13.5 13 13 12.5 12 79
25 10 10 10 9.5 9 9 8.5 76.5
JPF 2A, 3A, 4A, 41ATechnical data
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
12
13
Shallow Well Performance Curves
Performance curves JPF 2A, 3A, 4A, 41A
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
12
13
Dimensional Drawings
Dimensions and Weights
Pump
Type
Motor Data D1
Suction
NPT
D2
Disch.
NPT
D3
Re-
turn
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship
Vol.
(Cu
Ft.)
HP S.F. PH Volts A1 A2 B B1 C1 C2 E1 E2 F G H H1 H2 H3
JPF5A 1.5 1.5 1 230 1-1/4’ 1’ 1’ 22.0 15.3 8.3 11.0 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3 2.1 0.44 70 1.9
JPF7A 2 1.3 1 230 1-1/4’’ 1’’ 1’ 25.6 19.9 8.3 12.4 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3 2.1 0.44 73 2.5
Conversion Instructions
from Shallow Well to DeepWell
Remove bolts and detach ejector nose from
convertible jet pump. Connect suction (D1) and
pressure (D3) port to deep well ejector.
JPF 5A, 7A ConvertiblesTechnical data
Shallow Well
Deep Well
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
14
15
Shallow Well Performance Chart
Model HP Depth to Water
Discharge Pressure (PSI)
Shut-off (PSI) Pressure Switch
Settings (PSI)
20 30 35 40 45 50 55
Capacities (GPM)*
JPF5A 1-1/2
5 21 20.5 20 20 20 19 17.5 86.5
50-70
10 19 18.5 18 18 17.5 17.5 17 84
15 16 16 16 15.5 15 15 14.5 81.5
20 13.5 13.5 13.5 13 13 12.5 12 79
25 10 10 9.5 9 9 8.5 76.5
JPF7A 2
5 34 34 33.5 33 32.5 30 27 88
50-70
10 28.5 28 28 28 27.5 27 26 85.7
15 24 24 23.5 23.5 23 22.5 22 83
20 20 20 19.5 19.5 19.5 19 19 80
25 15.5 15.5 15.5 15 15 15 77.8
Performance Curves
Technical data JPF 5A, 7A Convertibles
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
14
15
Technical data
Deep Well Performance Chart
Model Ejector Type
Discharge Pressure (psig) Depth to water (feet)
30 40 50 60 70 80 90 100 120 140
Capacities USgph*
JPF5A
E20
45 896 794 682 586
50 727 615 505 404
60 575 438 320 220
65 365 247 130
75 177 63
E25
50 606 534
60 484 411
65 362 323
75 247 190
80 151 102
E30
50 449 406 358 302
60 373 333 293 248
65 306 271 234 190
75 244 214 177 125
80 190 162 137 113
JPF7A
E20
50 1054 945 859 703
60 854 755 633 510
65 664 589 430 305
75 469 365 221 102
80 253 156
E25
50 716 635 560 482
60 586 505 430 352
65 456 379 313 240
75 331 260 201 143
90 221 161 112
E30
65 478 411 371 310
75 383 341 306 262
80 318 281 247 215
90 255 226 195 157
95 203 177 148 116
JPF 5A, 7A Convertibles
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
16
17
Dimensional Drawings
Dimensions and Weights
Pump
Type
Motor Data D1
Suction
NPT
D2
Disch.
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship
Vol.
(Cu
Ft.)
HP S.F. PH Volts A B B1 C E F G H1 H2 L
JPS2A 1/2 1.5 1 115 or 230 1’’ 1’’ 14.8 7.5 9.3 3.7 4.8 7.1 4.3 9.1 7.0 0.83 0.42 24 1.5
JPS4A 1 1.36 1 115 or 230 1’’ 1’’ 15.6 7.5 9.3 3.7 4.8 7.1 4.3 9.1 7.0 0.83 0.42 31 1.5
Shallow Well Performance Chart
Model HP
Depth to Water Discharge Pressure (PSI) Shut-
off (PSI)
Pressure Switch Settings
(PSI)
20 30 35 40 45 50 55
Capacities (GPM)*
JPS2A 1/2
5 15 13 11 8 6 4 2 62
30-50
10 14 12 10 7 5 3 1 59.5
15 13 11 9 6 4 2 57
20 10 10 8 5 3 1 54.5
25 8 8 7 4 2 52
JPS4A 1
5 30 27 22 17 14 10 7 68
30-50
10 26 23 21 16 13 9 6 65.5
15 22 21 20 15 12 8 5 63
20 18 17 16 14 11 7 4 60.5
25 14 13 13 12 11 6 3 58
Technical data JPS 2A, 4A
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
16
17
Performance curves JPS 2A, 4A
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
18
19
Dimensional sketches
Dimensions and Weights
Pump
Type
Motor Data D1
Suction
NPT
D2
Disch.
NPT
D3
Return
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship
Vol.
(Cu
Ft.)
HP S.F. PH Volts A B B1 C E G H H1 H2
JDF2A 1/2 1.6 1 115 or 230 1.25’ 1’’ 1’ 15.2 7.1 9.1 3.5 8.0 0.38 5.5 8.9 1.9 3.6 36 1.5
JDF4A 3/4 1.3 1 115 or 230 1.25’’ 1’’’ 1’ 15.2 7.1 9.1 3.5 8.0 0.38 5.5 8.9 1.9 3.6 37 1.5
Ejector Dimensions
AE HE1 HE2 X Y Z
3.8 11.6 5.63 1’ NPT 1’’NPT 1.25’’NPT
3.8 11.6 5.63 1’’NPT 1’’NPT 1.25’’NPT
Technical data JDF 2A, 4A
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
18
19
Technical data JDF 2A, 4A
Performance Chart
Model Ejector Type
Discharge Pressure (psig) Depth to water (feet)
30 40 50 60 70 100 120
Capacities USgph*
JDF2A
E20
20
30
35
45
SHUTOFF
E25
20 625 510 395
30 350 270 175
35 230 155 70
45 60
SHUTOFF 49 44 42
E30
20 500 430 375
30 355 295 240
35 290 230 175
45 175 125 80
50 125 75 40
SHUTOFF 63 58 55
JDF4A
E20
20
30
35
45
SHUTOFF
E25
20 800 670 525
30 525 410 290
35 400 280 175
45 160 65
SHUTOFF 53 49 45
E30
30 360 325 265 210
35 320 260 200 160
45 190 140 100 75
50 135 95 65 35
SHUTOFF 72 65 60 57
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
20
21
Performance curves JPF Pump Package*
*Only available in Canada
Dimensional Drawings
Dimensions and Weights
Pump Type Motor Data D1
Suction
NPT
D2
Disch.
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship
Vol.
(Cu
Ft.)
HP S.F. PH Volts A B B1 C D E F G H1
JPF3A 1/2 1 1 115 or 230 1’ 1’’’ 1.2 11.9 9.1 5.5 9.1 7.1 15.2 11.9 6.0 7.0 5.0
Shallow Well Performance Chart
Model HP
Depth to Water Discharge Pressure (PSI) Shut-
off (PSI)
Pressure Switch Settings
(PSI)
20 30 35 40 45 50 55
Capacities (GPM)*
JPF3A 1/2
5 12 11 11 10 7 6 4 73.5
30-50
10 10.5 10 10 9.5 7 6 4 71
15 9 8.5 8 8 7 6 4 68.5
20 7.5 7 7 7 6.5 6 4 66
25 5 5 5 5 4.5 4 4 63.5
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
20
21
Technical data
Dimensional Drawings
Dimensions and Weights
Pump
Type
Motor Data D1
Suction
NPT
D2
Disch.
NPT
Dimensions (inches) Ship
Wt.
(lbs)
Ship Vol.
(Cu Ft.)
HP S.F. PH Volts A B B1 C E F G H1 H2
JPS2A 1/2 1.5 1 115 or 230 1’’ 1’’ 14.8 11.9 9.3 3.7 7.1 15.2 11.9 8.5 6.0 0.38 45.0 5.0
Shallow Well Performance Chart
Model HP
Depth to Water Discharge Pressure (PSI) Shut-
off (PSI)
Pressure Switch Settings
(PSI)
20 30 35 40 45 50 55
Capacities (GPM)*
JPS2A 1/2
5 15 13 11 8 6 4 2 62
30-50
10 14 12 10 7 5 3 1 59.5
15 13 11 9 6 4 2 57
20 10 10 8 5 3 1 54.5
25 8 8 7 4 2 52
JPS Pump Package*
*Only available in Canada
info@lenntech.com - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
22
U.S.A.
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: (913) 227-3400
Telefax: (913) 227-3500
Canada
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario
L6H 6C9
Phone: (905) 829-9533
Telefax: (905) 829-9512
Mexico
Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L. Mexico
Phone: 011-52-81-8144 4000
Telefax: 011-52-81-8144 4010
www.grundfos.com
L-JP-PG-001 5/03
PRINTED IN USA Subject to alterations.
Being responsible is our foundation