Highly efficient with balanced illumination and versatility. H9S2GLR128 OR 228 HP90 2' X 4' DIRECT/INDIRECT RECESSED FLUORESCENT ACRYLIC LINEAR PRISMATIC LENS STATIC, 1 OR 2 LAMP T5 Project: HP90 combines a recessed contoured body with an enclosed linear prismatic translucent lens to create an exciting highly efficient direct/indirect luminaire. Location: Catalog No: Fixture Type: Mfg: Lamps: Qty: Notes: Ordering Guide HP90 H9 Direct/ Indirect Recessed Body Style S S= Static Explanation of Catalog Number Example: H9S2GLR128UNVHI Fixture Width 2 2 = 2' Ceiling Type G Fits Both Standard Grid and Slot Grid Lens Type L L= Acrylic Lens Reflector Lamp Qty R R= Specular Aluminum Lamp/ Fixture Length Voltage Ballast Type 28 1= 1 Lamp 2= 2 Lamp (By Others) UNV = 120/277V <10THD 1 or 2 Lamp Elec. T5 28 = T5 28W 120 = 120V PG Program Start (Nominal 48") 277 = 277V VY 1 or 2 Lamp Elec. T5 347 = 347V Program Start Step-Dim WA 1 or 2 Lamp Elec. T5 Instant Start (120V or 277V Only) PF 1 or 2 Lamp Elec. T5 LOL Dimming NOTE: 347V. Emergency in T5/T5HO Not Available. Please Consult Your Philips Lighting Representative for 120V and 277V. © 2013 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires HP90 H9S2GLR128 OR 228 08/13 page 1 of 3 Options Add Appropriate Suffix to Catalog No. H9S2GLR128 OR 228 HP90 Features Specifications •C an provide 54.6 maintained footcandles of balanced brightness illumination at only .68 watts per square foot. • 87.2% efficient (1 lamp, 28W T5). • 90.4% efficient (2 lamp, 28W T5). • Direct/indirect appearance with soft contoured interior. • Lens encloses lamp compartment. • Translucent DR acrylic linear prismatic lens. • Tension screws secure ends to body. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. • Lamp shield opens from either side. • 95% reflective specular aluminum reflector. • Ballast accessible from room side. • Can be continuous row mounted. • Wiring access plate standard. • Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices. Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .94. To reduce glare the average brightness at 65° shall not exceed 2574 candelas per square meter. To control veiling reflections, luminaire output in the 30°–90° zone shall not be less than 73.8% Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org Options/Accessories Materials: Chassis parts are die-formed code gauge steel. Electrical/Wiring Options: Consult your Philips Lighting representative. Lamp Shield: Linear prismatic translucent DR acrylic lens. Drywall Kit: Order catalog number: FK92X4. Fusing: Internal fast-blow fusing. Suffix: F. Finish: Chassis Exterior—Baked white acrylic enamel. Cavity—baked flat white acrylic enamel. Phosphate undercoating. Reflector—low iridescence specular aluminum 95% reflectance. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Dimensions Mounting Methods Exposed T-bar by Others 5" (127mm) 1½" Max. 5" (127mm) 24" (610mm) 24" Exposed T-bar by Others Acoustical Material by Others 1⅞" Max. / " 15 16 Exposed T-grid Ceiling *For flush mounting when using 9 /16" Exposed T-Grid ceiling system consult your Philips Lighting representative 24" / " 9 16 Exposed Slot T-grid Ceiling 2½" (64mm) 2" x 2½" Access Plate with (2) ⅞" dia. K.O. 48" (1219mm) Built-in Earthquake Clips © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires HP90 H9S2GLR128 OR 228 08/13 page 2 of 3 Acoustical material by Others Fully Enclosed Lamp Compartment H9S2GLR128 OR 228 HP90 Performance Model No. H9S2GLR128UNVPG Coefficients of Utilization Candela Distribution Angle 0.0 45.0 90.0 0 833 833 833 5 825 832 840 80 15 801 817 825 230 25 752 754 746 346 35 677 638 625 403 Ballast: QTP 2X28 T5/UNV-PSN Report is based on 2610 lumens per lamp. 45 562 502 509 397 55 399 367 403 341 Efficiency: 87.2% 65 227 253 334 266 CIE Type: Direct-Indirect 75 97 174 241 179 36 Report Number: G2006156 Catalog Number: H9S2GLR128UNVPG Lamp: (1) F28 T5 Luminaire: HP90 2' x 4' with linear prismatic lens. Plane: 0 Deg. 90 Deg. 85 19 29 27 1.3 1.2 90 2 2 2 Spacing Criteria: 90 90 Plane: 0 Deg. 90 Deg. Luminous Length: 47.760 23.760 Shielding Angles: FLUX Ceiling Wall Luminance Data in Candela/Sq. Meter Average in Deg. Average 0 Deg. Average 45 Deg. Average 90 Deg. 45 55 65 75 85 1143. 1000. 772. 538. 313. 1020. 919. 859. 965. 486. 1035. 1009. 1137. 1340. 439. 80% 70 50 50% 30 50 30 30% 10 50 30 10 Zonal Cavity Method— Effective Floor Cavity Reflectance = 0.20 RCR Room Cavity Ratio LER = FP–75.8 IW–31.55 BF–1.0 Comparative yearly lighting energy cost per 1000 lumens = $3.16 1 2 3 4 5 6 7 8 9 10 95 86 79 72 66 61 57 53 50 47 91 79 70 62 55 50 45 41 38 35 85 74 66 58 52 47 43 40 36 34 87 73 62 54 47 42 38 34 31 28 80 66 55 47 41 36 32 29 26 24 82 70 60 52 46 41 37 33 30 28 82 71 63 56 51 46 42 39 36 33 79 68 58 51 45 40 36 33 30 27 77 64 54 47 41 36 32 28 26 23 Zonal Lumen Summary Zone Lumens % Lamp % Fixt 0–30 0–40 0–60 0–90 90–180 0–180 690 1115 1892 2398 0 2398 25.1 40.5 68.8 87.2 0.0 87.2 28.8 46.5 78.9 100.0 0.0 100.0 Model No. H9S2GLR228120WA Coefficients of Utilization Candela Distribution Angle 0.0 45.0 90.0 0 1481 1481 1481 5 1471 1474 1478 140 15 1421 1429 1446 404 25 1298 1344 1398 620 35 1131 1219 1301 763 Ballast: WA Report is based on 2610 lumens per lamp. 45 921 1061 1175 814 55 673 872 1006 767 Efficiency: 90.4% 65 412 659 803 629 CIE Type: Direct-Indirect 75 191 424 490 394 77 Report Number: G2006010 Catalog Number: H9S2GLR228120WA Lamp: (1) F28 T5 Luminaire: HP90 2' x 4' with linear prismatic lens. Plane: Spacing Criteria: 0 Deg. 90 Deg. 85 40 63 41 1.2 1.4 90 3 3 3 90 90 Plane: 0 Deg. 90 Deg. Luminous Length: 46.800 22.800 Shielding Angles: FLUX Wall Luminance Data in Candela/Sq. Meter Average in Deg. Average 0 Deg. Average 45 Deg. Average 90 Deg. 45 55 65 75 85 2152. 1970. 1739. 1403. 850. 2401. 2256. 2206. 2396. 1200. 2468. 2382. 2574. 2682. 1000. © 2013 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires HP90 H9S2GLR128 OR 228 08/13 page 3 of 3 Ceiling 80% 70 50 50% 30 50 30 30% 10 50 30 10 Zonal Cavity Method— Effective Floor Cavity Reflectance = 0.20 RCR Room Cavity Ratio LER = FP–84.3 IW–54.6 BF–0.93 Comparative yearly lighting energy cost per 1000 lumens = $2.85 1 2 3 4 5 6 7 8 9 10 98 89 81 74 68 63 58 54 50 47 94 81 71 63 56 50 46 42 38 35 90 75 63 55 48 42 38 34 31 28 88 76 67 59 53 48 43 40 37 34 85 71 61 53 46 41 37 33 30 27 82 67 56 47 41 36 32 28 25 23 84 73 64 57 51 46 42 39 36 33 82 69 59 51 45 40 36 32 30 27 79 66 55 47 40 35 31 28 25 23 Zonal Lumen Summary Zone 0–30 0–40 0–60 0–90 90–180 0–180 Lumens % Lamp % Fixt 1520 2445 3423 3496 0 3496 26.3 42.9 60.1 61.3 0.0 61.3 43.0 69.9 97.9 100.0 0.0 100.0 Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2013:08:27 13:17:12-04:00 Metadata Date : 2013:11:07 13:02:18-05:00 Modify Date : 2013:11:07 13:02:18-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:67728c3a-2e95-f84e-8c74-cd15d042c5b5 Original Document ID : xmp.did:0480117407206811994CA18396A118C7 Document ID : xmp.id:C1368D201F2068118083BEC6557692E3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:C0368D201F2068118083BEC6557692E3 Derived From Document ID : xmp.did:890A28DA3B206811822AF9D430E829CD Derived From Original Document ID: xmp.did:0480117407206811994CA18396A118C7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:08:27 13:17:12-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False State : 1 Version : 1.1 Page Count : 3 Creator : Adobe InDesign CS6 (Macintosh) Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools