475 Field Communicator Product Data Sheet May 2013 475 Field Communicator Full-color graphical user interface Powerful field diagnostics Bluetooth® communication Long-lasting Lithium-Ion power module Universal support for HART® and Foundation™ fieldbus devices The 475 Field Communicator is designed to support all HART and Foundation fieldbus devices from all vendors. Introduction Product Description The 475 Field Communicator builds on the industry-leading technology of the 375 Field Communicator while adding innovative new capabilities including color display, Bluetooth communication, and advanced field diagnostics with applications like ValveLink™ Mobile. The 475 Field Communicator is designed to simplify your work in the field. The intuitive full color user interface allows you to leverage the same practices for both HART and Foundation fieldbus devices. It includes a larger touch screen than PDAs or Pocket PCs, supports HART versions 5, 6, and 7 (including WirelessHART™) devices, and allows you to upgrade your 475 Field Communicator onsite using the Internet. What you get is the most powerful handheld available – universal, user upgradeable, intrinsically safe, rugged and reliable. Only the 475 Field Communicator can deliver all this in a single handheld communicator. See and Feel the Difference The touch screen display uses transflective technology, making it easy to read in both bright sunlight and normal lighting. To make sure all conditions are covered, a multi-level backlight is included, allowing bright, crisp display even in plant areas with dim light. 475 Field Communicator May 2013 Gain advanced diagnostics in the field through ValveLink Mobile and enhanced graphics. The touch screen display and large physical navigation buttons provide for efficient use both on the bench and in the field. The icon-based user interface allows you to navigate quickly and efficiently. The full color graphics capability is provided as standard with every 475 Field Communicator. It uses powerful EDDL technology to allow you to read data from field devices in a graphical manner. Charts, graphs, gauges, and product images are just a few of the ways in which important device data can be displayed using the 475 Field Communicator’s color LCD display. The weight of the 475 Field Communicator is evenly distributed for comfortable one-handed operation in the field. It runs on Windows CE, a robust, real-time operating system. The 475 Field Communicator has plenty of memory to allow for future expansion. It has 32 MB of application memory and 1 GB of memory on its System Card. New HART and Foundation fieldbus devices, as well as functional updates to existing devices, are introduced continually by device vendors. Keeping up-to-date with the required Device Descriptions (DDs) for all the devices in your plant can be a real challenge. With Easy Upgrade, when new HART and Foundation fieldbus DDs become available, you can simply download them from the Internet and upgrade your 475 Field Communicator. Update at your site, within your control, when it’s convenient for you. Online Licensing The Easy Upgrade Utility allows you to transfer system software, DDs, and HART device configurations between the 475 Field Communicator and a PC. 2 The Online Licensing capability provided with Easy Upgrade allows you to enable new options for your 475 Field Communicator over the Internet. With Online Licensing, powerful options like Foundation fieldbus can be added by simply purchasing the license and downloading it directly to your communicator. www.fieldcommunicator.com 475 Field Communicator May 2013 The 475 Field Communicator, with its handy carrying case, provides a single tool for configuring and diagnosing HART and Foundation fieldbus devices. Universal – HART and Foundation fieldbus With over 1,300 different HART and Foundation fieldbus devices available from more than 100 manufacturers, the 475 Field Communicator works with all your devices to positively impact your bottom line. Through Easy Upgrade, you always have access to the latest HART and fieldbus drivers. With the 475 Field Communicator, you are guaranteed universal HART and Foundation fieldbus support in a single, intrinsically safe handheld communicator. Intrinsically Safe The 475 Field Communicator meets the Intrinsic Safety requirements of the listed regulatory agencies and standards. All of the available Hazardous Locations approvals are provided in a single model option (see Ordering Information). CENELEC/ATEXvibration is present. Factory Mutual (FM) Canadian Standards Association (CSA) FISCO IECEx Even the power module is approved for installation in hazardous areas. Rugged and Reliable It’s called “Field Communicator” for a reason. Some tasks just have to be performed at the device in the field. The 475 Field Communicator is designed for tough use in your plant or mill. Its large keys and physical navigation buttons allow for one-handed operation, even with your work gloves on. The rugged display is designed to take the knocks and shocks from normal use in the plant. Device Configuration Tag: PT-105 Manufacturer: Rosemount Model: 3051S Diag 146 Variables Printed on: 5/19/2009 9:06:38 AM Parameter Variation Custom S... 2nd Variable 3rd Variable Abnormal Situation P... Alarm Direction Analog Output Baseline Mean Value... Baseline Standard D... Burst Mode Burst Option Calibration Type Cutoff Mode Damping Damping Date Descriptor Dev flags Device Status Diaphragm Material Distributor Drain Vent Matl Electronics HW Rev Electronics S/N Electronics SW Rev Fact trm recal loc Field Device Rev Value 100% Sensor Temperature Scaled Variable 0x00 Hi 3,999 mA 0.000000 inH20 0.000000 inH20 Off Unknown Enumerato... Diff (DP) Off 0.90 s 0.00 s 02/14/2008 PRODUCTION XMT... 0x00 0x50 None Rosemount 316 SST 1 407 5 Sensor trim 1 Parameter Lower Sensor Limit Lower Trim Point Manufacturer Maximum Temperat... Mean Mean Change Check Mean Change Sensit... Mean Chg Action Mean Custom Sens... Mean Lower Thresh... Mean Upper Thresh... Measurement Message Min Span Min Span Min Span Mode Model Model Number I Model Number II Model Number III Module Config Module Range No Label Available Num req preams Number Value 0.00000 0.0 Rosemount 80.002 F -0.031420 inH20 6* Medium Alert 100% 0.000000 inH20 0.000000 inH20 Diff (DP) MISSING CAP 4.5 0.00000 0.0 Off 3051S Diag 1 2 3 Std coplanar (C) 3 0x00 5 None Easily store and print device configurations for analysis and documentation requirements. ATEX 3 www.fieldcommunicator.com 475 Field Communicator May 2013 AMS Device Manager uses the intelligence from field devices to create a predictive maintenance environment. AMS Device Manager allows you to configure, calibrate, document, and troubleshoot HART, Foundation fieldbus, and WirelessHART devices. Transfer device configuration data to AMS Device Manager via the IrDA port or Bluetooth interface on your 475 Field Communicator and PC. Take your 475 Field Communicator out to the field to configure or update one or more devices. Save up to 1,000 device configurations in your communicator or transfer them to AMS Device Manager. The protective rubber boot provides added protection in the field. Together, the 475 Field Communicator and AMS Device Manager enable you to efficiently manage all of your devices. The 475 Field Communicator’s Protective Rubber Boot provides added protection in the field and in your toolbox. Both the rubber boot and 475 housing are designed in accordance with Intrinsic Safety standards to limit the build up of static electrical energy. Device Configuration Management The 475 Field Communicator is designed, manufactured, and tested to very demanding specifications. It is ready to go wherever you need to go to get the job done. Identify Valve Problems Powerful Diagnostics Interface with AMS Device Manager The 475 Field Communicator is fully compatible with AMS Device Manager, the industry standard for asset management software. In fact, Control Magazine readers have selected AMS Device Manager as the #1 Calibration Software package for over 13 years in a row. Using the Easy Upgrade Utility, you can back up hundreds of device configurations and can transfer them between your communicator and a PC. This library of device configurations is easy to view and print for analysis. Run valve diagnostics in the field with the ValveLink Mobile application. You can quickly perform tests including valve signature, dynamic error band, PD one button sweep, and step response on HART and Foundation fieldbus Fisher® FIELDVUE™ digital valve controllers. The intuitive user interface makes ValveLink Mobile easy to use and understand. Diagnose issues in the field or transfer the results to an asset management system like AMS Suite for in-depth analysis and documentation. Diagnose Network Problems The 475 Field Communicator can be used to configure all the Foundation fieldbus devices in your plant. Use it to perform diagnostics for effective start-up and troubleshooting of fieldbus segments. Create a quality segment by diagnosing the network DC voltage and average noise. Detect power supply problems by monitoring low frequency noise on a segment. Locate incorrect terminations and faulty devices by diagnosing the communications signal level. For HART loops, the 475 Field Communicator allows you to verify whether the DC voltage in the loop is correct. 4 www.fieldcommunicator.com 475 Field Communicator May 2013 Specifications Processor And Memory Microprocessor 80 MHz Hitachi® SH3 Memory Internal Flash 32 MB System Card 1 GB secure digital card RAM 32 MB Physical Weight Approximately 1.65 lb. (0.75kg) with battery Display 1/4 VGA (240 by 320 pixels) color, 3.5 in. (8.9 cm) transflective display with touchscreen Anti-glare coated Keypad 25 keys including 4 action keys, 12 alphanumeric keys, tab key, function key, backlight key, power key, and 4 cursor-control (arrow) keys; membrane design with tactile feedback Power Supply / Charger Battery Rechargeable Lithium-Ion power module Battery Operating Time 20 hours – continuous use 40 hours – typical use 80 hours – standby mode Battery Charger Options Input voltage 100-240 VAC, 50-60 Hz Cables included with U.S., Europe, and U.K. plugs Connection Battery Charger Mini DIN 6-pin jack HART and Fieldbus Three 4mm banana jacks (one common to HART and Foundation fieldbus IrDA Port IrDA (Infrared Data Access) port supporting up to 115 Kbps ± 15 degrees recommended maximum angle from center line Approximately 18 in. (45.7 cm) recommended maximum distance Bluetooth Up to 32.8 ft. (10 m) communication distance Uses standard Windows drivers FCC, IC, and CE approvals Certified for use in over 60 countries Environmental Usage -10°C (14°F) to +50°C (122°F) Battery 0% to 95% RH (non-condensing) for 0°C (32°F) to +50°C (122°F) Charge 10°C (50°F) to +40°C (104°F) Storage With Batteries -20°C (-4°F) to +55°C (131°F) Storage Without Batteries -20°C (-4°F) to +60°C (140°F) Enclosure Rating IP51 (from front) Shock Tested to survive a 1-meter drop test onto concrete Easy Upgrade Requirements Usage PC with Internet access CD Rom drive IrDA port (or adapter) or Bluetooth (or adapter) SD Card Reader (required for some upgrades) Windows XP (SP2 or SP3), Windows Vista Business (SP1), or Windows 7 5 www.fieldcommunicator.com 475 Field Communicator May 2013 475 Field Communicator Spare Parts List Description Part Number 00275-0096-0001 Ruggedized 250 Ohm Load Resistor 00475-0002-0022 Rechargeable Lithium-Ion Power Module 00475-0003-0022 Power Supply & Charger (Li-ion/NiMH) US/UK/EU connection types included 00375-0003-0002 Power Supply/Charger Standard Cord Set (US/UK/EU cords) 00375-0003-0003 Australian (AU) cord for Power Supply/Charger 00375-0004-0001 Lead Set with connectors 00475-0005-0002 Hand Strap (pack of 2) 00475-0005-0003 Carrying Case (with spare Hand Strap and Stylus) 00475-0005-0004 Magnetic Hanger 00475-0005-0005 Protective Rubber Boot with Stand 00475-0006-0001 Stylus (pack of 2) 00375-0015-0002 IrDA to USB Adapter (1) 00375-0018-0022 System Card (SD) Reader (with USB Interface) (2) 00475-0018-0023 Bluetooth Adapter (1) (9) 00475-0044-0001 Stand 00475-0019-FK01 Field Accessory Kit (6) 00475-0019-SK01 Shop Accessory Kit (Bluetooth) (7) (9) 00475-0019-SK02 Shop Accessory Kit (non-Bluetooth) (7) 00475-0045-3001 Getting Started Guide 00475-0049-0001 Resource CD (8) 00475-0049-DVD1 Resource DVD 00475-0050-TRN1 Technical Training CD Online Licensing (4) 00375-0142-0002 FOUNDATION fieldbus License Via Web 00475-0142-2003 Easy Upgrade (New/Renew) License via Web (3) AMS Device Manager Handheld Interface Kit (5) AW7005HC00025 AMS Device Manager Field Communicator Interface Kit (25 tags) AW7005HC20000 AMS Device Manager Field Communicator Interface Kit (100 Tags and above) (1) Can be used to support communication between the 375/475 and the Easy Upgrade Programming Utility or AMS Device Manager (with Handheld Communicator Interface Kit). Either IrDA or Bluetooth communication is required to register the 375/475 or use the Online Licensing system. (2) The System Card (SD) Reader allows a user the ability to upgrade a System Card much faster than when using IRDA or Bluetooth. Due to file size constraints, major upgrades require the use of a card reader. (3) The Easy Upgrade feature allows users to add new System Application software and Device Descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this feature, the System Card would have to be sent to a Service Center (fee would apply). When purchased, the expiration date becomes three (3) years from the date of the PO of three (3) years from the expiration date of the current license - whichever is greater. Current license can only be renewed within 6 months of the expiration date on the current license. (4) These parts support license upgrades of System Cards in the field through the use of the Field Communicator Online Licensing system. The capacity is available to end users and may also performed by an agent on the user’s behalf. It is at the agents discretion if an additional fee should apply. Any order must be accompanied by the System Card S/N. Instant notification of when the licenses are available for download are sent to emails provided at time of order. For further details, see the Online Licensing procedure at www.fieldcommunicator.com. (5) Requires AMS Device Manager (v6.2 or higher). Both AMS Device Manager and the Handheld Communicator Interface Kit are available for sale through select channels only. See www.assetweb.com for more details. (6) Contains Protective Rubber Boot, Ruggedized 250 Ohm Load Resistor, Magnetic Hanger, Stylus Pack, and Technical Training CD. (7) Contains Field Accessory Kit plus System Card Reader, Bluetooth Adapter, and Resource CD and DVD. Non-Bluetooth model substitues IRDA to USB adapter for Bluetooth adapter. (8) Same content as Resource CD, but also includes localized versions for English, German, Russian, and Japanese. (9) Not available for purchase from Rosemount - Chanhassen. Use alternative channel to order this part. 6 www.fieldcommunicator.com 475 Field Communicator May 2013 475 Field Communicator Ordering Information Model Product Description 475 Field Communicator (1) Code Communication Protocol H HART F HART and Foundation fieldbus (2) Code Battery Type P Rechargeable Lithium-Ion Power Module Code Power Supply/Charger 1 Power Supply and Charger NiMH/Li-Ion (US/UK/EU connection types included) (3) 9 Not included (4) Code Language E English C Chinese D German J Japanese R Russian F French P Portuguese Code Product Certifications KL ATEX, FM, CSA and IECEx Intrinsically Safe (includes FISCO as applicable) NA No Approval Code Easy Upgrade U Easy Upgrade (3 year) Option (5) 9 Not Included Code Standard Options GM Graphics (included at No Charge) (6) Device Configuration Management (included at No Charge) (7) Code Bluetooth T Bluetooth Communication (8) 9 No Bluetooth Communication Code Options A Spare Rechargeable Lithium-Ion Power Module (9) S Protective Rubber Boot with Stand Typical HART Model Number: Typical HART/Fieldbus Model Number: (1) (2) (3) (4) (5) 475 H P 1 E KL U GMT S 475 F P 1 E KL U GMT S Base Model 475 includes Field Communicator unit with Color LCD display, System Card, leadset with connectors, carrying case, Getting Started Guide, Resource CD, stylus, and straps. Must specify Easy Upgrade Option (Code U) when ordering this model option. To obtain an Australia power cord, order part number 00375-0003-0003. This option should only be considered if the user already has a 375 or 475 Power Supply/Charger. If it is a 375 Power Supply / Charger, it must be the Li-Ion/NiMH version. The Easy Upgrade capability allows users to add new System Application software and Device Descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this feature, the System Card would have to be sent to a Service Center. The Graphics functionality enables a user to access enhanced grapical features when using the HART or Foundation fieldbus application. Device Configuration Management provides the capablity to store in excess of 1,000 configurations and print them. Bluetooth enables communication to a PC via the Bluetooth protocol. A fully charged Lithium-Ion Power Module is capable of delivering power for 20 hours of typical field use. If requirements exceed this specification, a Spare Power Module (code A) should be specified. (6) (7) (8) (9) 7 www.fieldcommunicator.com 475 Field Communicator May 2013 ©2014, Emerson Process Management. Emerson Process Management 12001 Technology Drive Eden Prairie, MN 55344 USA T 1(952) 828-3633 F 1(952) 828-3006 www.fieldcommunicator.com The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. All rights reserved. AMS is a mark of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2014:04:26 04:54:16+08:00 Metadata Date : 2014:04:26 04:55:12+08:00 Modify Date : 2014:04:26 04:55:12+08:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:292bdc69-f287-4c94-8dac-4db9015cb68b Original Document ID : xmp.did:4e68d107-af64-dc4c-bd92-d3dd79a7f5a4 Document ID : xmp.id:3fa0fa0f-6efd-c44c-8f9b-1932f3298bb4 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:e8498ced-9d20-8747-b799-41be13bee0e8 Derived From Document ID : xmp.did:d050da11-6532-cd4b-b580-b63e5f11c0b9 Derived From Original Document ID: xmp.did:4e68d107-af64-dc4c-bd92-d3dd79a7f5a4 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:04:26 04:54:16+08:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools