RE040290 4208 Family 4208U Data Sheet Honeywell 4208UData
User Manual: 4208U Data Sheet 4208U - Honeywell Ademco
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
4208SN Serialized Eight Zone Remote Point Module The 4208SN Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on ADEMCO controls that support V-Plex polling loop devices. FEATURES • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied) • Can be used on controls that support up to 250 zones • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop • Each zone is identified by a unique serial number, which is assigned via on-board DIP Switches • Detects faults on all zones within 400ms of occurrence • Loops A & B can be programmed for fast (10ms) response • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches SPECIFICATIONS Physical Expander Sensor Loop Response Sensor Loop Max. Resistance • 6-7/16”W X 4-1/4”H X 1-1/4” D 163mm x 108mm x 32mm Electrical • Slow: 400msec (all loops) • Fast: 10msec (option for loops A and B) Expander Sensor Loop Current • Up to 300 ohms of wire resistance + 10K EOLR Agency Listings Polling Loop Voltage • 0.52mA (normal) • 1.3mA (shorted) NOTE: These currents apply when polling loop input = 11VDC and 10VDC input is not connected to external supply • 11V nominal; 8.7 - 14VDC range Current • 33.6mA when polling loop provides power to module, 0.6mA when 12VDC input provides power to module. See chart below. 12VDC Input Voltage • 12V nominal; 9.4 - 14VDC range Power Input Source Current Draw (all zones shorted) From Polling Loop From External Power Polling Loop Only 33.6m AN/A Polling Loop and External Power Input 0.6mA 33mA ORDERING 4208SN Eight Zone Expander • • • • • • • • UL 985 Household Fire UL 1023 Household Burglary UL 609 Commercial Burglary UL 864 Commercial Fire CSFM FM (Pending) CUL CE (requires #N6361) For UL Listed Commercial Fire Usage: Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately). For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied. 4208U Universal Eight Zone Remote Point Module The 4208U Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on ADEMCO controls that support V-Plex polling loop devices. FEATURES • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied) • DIP Switches can be used to set zone numbers or serial numbers • Loops A & B can be programmed for fast (10msec) response • When used in the serial number mode, each serial number in the selected group can be assigned to any zone number • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches External Power Input (optional): • 12VDC @ 28mA (from control panel’s auxiliary power) Sensor Loop Response: Sensor Loop Max. Current: • Slow: 400 msec (all loops) • Fast: 10msec (option for loops A and B) Sensor Loop Current: • • • • • • • • SPECIFICATIONS Physical • 6-7/16” W X 4-1/4”H X 1-1/4”D 163mm X 108mm X 32mm Electrical Polling Loop input: • 7.3 - 14VDC range Current draw: • 28.6mA max. External power and polling loop. See chart below. • Polling loop input = 11VDC, no external power input):0.52mA (normal), 1.3mA (shorted) Power Input Source (Input Voltage: 11-14VDC) Current Draw (all zones shorted) From Polling Loop From External Power Polling Loop Only 27.3mA N/A Polling Loop and External Power Input 0.6mA 33mA ORDERING 4208U Eight Zone Expander Honeywell Security & Custom Electronics PO Box 9035, Syosset, NY 11791 www.security.honeywell.com/sce L/4208FAM/D November 2004 ©2004 Honeywell International Inc. • Up to 300 ohms of wire resistance + 10K EOLR Agency Listings UL 985 Household Fire UL 1023 Household Burglary UL 609 Commercial Burglary UL 864 Commercial Fire CSFM FM CUL CE (requires #N6361) For UL Listed Commercial Fire Usage: Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately). For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : Lynne Create Date : 2004:11:22 19:52:20Z Keywords : Serialized, Eight, Zone, Remote, Point, Module Modify Date : 2010:05:26 13:48:57-04:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 5.0.5 for Macintosh Metadata Date : 2010:05:26 13:48:57-04:00 Creator Tool : QuarkXPress.: LaserWriter 8.7 8.7 Document ID : uuid:a9a7b247-49fb-11d9-8f82-0003933e9d82 Instance ID : uuid:62cfc7c4-8c48-4ae6-9b7a-5edfae850513 Format : application/pdf Creator : Lynne Title : RE040290 4208 family Page Layout : SinglePage Page Count : 2EXIF Metadata provided by EXIF.tools