4208SN
Serialized Eight Zone Remote Point Module
The 4208SN Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on
ADEMCO controls that support V-Plex polling loop devices.

FEATURES
• Uniquely identifies eight EOLR
supervised zones (all zones use
10K resistors, supplied)

• Can be used on controls that
support up to 250 zones
• Can be optionally powered from an
external DC power supply to
reduce the amount of current draw
from the polling loop

• Each zone is identified by a unique
serial number, which is assigned via
on-board DIP Switches

• Detects faults on all zones within
400ms of occurrence
• Loops A & B can be programmed
for fast (10ms) response
• Provides cover tamper protection,
which may be enabled or disabled
via on-board DIP Switches

SPECIFICATIONS
Physical

Expander Sensor Loop Response

Sensor Loop Max. Resistance

• 6-7/16”W X 4-1/4”H X 1-1/4” D
163mm x 108mm x 32mm
Electrical

• Slow: 400msec (all loops)
• Fast: 10msec (option for loops A
and B)
Expander Sensor Loop Current

• Up to 300 ohms of wire resistance +
10K EOLR
Agency Listings

Polling Loop Voltage

• 0.52mA (normal)
• 1.3mA (shorted)
NOTE: These currents apply when
polling loop input = 11VDC and
10VDC input is not connected to
external supply

• 11V nominal; 8.7 - 14VDC range
Current
• 33.6mA when polling loop provides
power to module, 0.6mA when
12VDC input provides power to
module. See chart below.
12VDC Input Voltage
• 12V nominal; 9.4 - 14VDC range

Power Input Source

Current Draw (all zones shorted)
From Polling Loop

From External Power

Polling Loop Only

33.6m

AN/A

Polling Loop and
External Power Input

0.6mA

33mA

ORDERING
4208SN

Eight Zone Expander

•
•
•
•
•
•
•
•

UL 985 Household Fire
UL 1023 Household Burglary
UL 609 Commercial Burglary
UL 864 Commercial Fire
CSFM
FM (Pending)
CUL
CE (requires #N6361)

For UL Listed Commercial Fire
Usage:
Use N.O. contacts. Style B
supervise these loops using Model
#EOL 100 fire listed 10K EOLRs
(purchased separately).
For UL Listed Commercial
Burglary Usage:
Use N.O. or N.C. contacts.
Supervise using EOLRs supplied.

4208U
Universal Eight Zone Remote Point Module
The 4208U Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on
ADEMCO controls that support V-Plex polling loop devices.

FEATURES
• Can be optionally powered from an
external DC power supply to reduce
the amount of current draw from the
polling loop
• Uniquely identifies eight EOLR
supervised zones (all zones use 10K
resistors, supplied)

• DIP Switches can be used to set
zone numbers or serial numbers

• Loops A & B can be programmed for
fast (10msec) response

• When used in the serial number
mode, each serial number in the
selected group can be assigned to
any zone number

• Provides cover tamper protection,
which may be enabled or disabled
via on-board DIP Switches

External Power Input (optional):
• 12VDC @ 28mA (from control panel’s
auxiliary power)
Sensor Loop Response:

Sensor Loop Max. Current:

• Slow: 400 msec (all loops)
• Fast: 10msec (option for loops A
and B)
Sensor Loop Current:

•
•
•
•
•
•
•
•

SPECIFICATIONS
Physical
• 6-7/16” W X 4-1/4”H X 1-1/4”D
163mm X 108mm X 32mm
Electrical
Polling Loop input:
• 7.3 - 14VDC range
Current draw:
• 28.6mA max. External power and
polling loop. See chart below.

• Polling loop input = 11VDC, no
external power input):0.52mA
(normal), 1.3mA (shorted)

Power Input Source
(Input Voltage: 11-14VDC)

Current Draw (all zones shorted)
From Polling Loop

From External Power

Polling Loop Only

27.3mA

N/A

Polling Loop and
External Power Input

0.6mA

33mA

ORDERING
4208U

Eight Zone Expander

Honeywell Security & Custom Electronics
PO Box 9035,
Syosset, NY 11791
www.security.honeywell.com/sce

L/4208FAM/D
November 2004
©2004 Honeywell International Inc.

• Up to 300 ohms of wire resistance +
10K EOLR
Agency Listings
UL 985 Household Fire
UL 1023 Household Burglary
UL 609 Commercial Burglary
UL 864 Commercial Fire
CSFM
FM
CUL
CE (requires #N6361)

For UL Listed Commercial Fire Usage:
Use N.O. contacts. Style B supervise these
loops using Model #EOL 100 fire listed 10K
EOLRs (purchased separately).
For UL Listed Commercial Burglary Usage:
Use N.O. or N.C. contacts. Supervise using
EOLRs supplied.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Lynne
Create Date                     : 2004:11:22 19:52:20Z
Keywords                        : Serialized, Eight, Zone, Remote, Point, Module
Modify Date                     : 2010:05:26 13:48:57-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Metadata Date                   : 2010:05:26 13:48:57-04:00
Creator Tool                    : QuarkXPress.: LaserWriter 8.7 8.7
Document ID                     : uuid:a9a7b247-49fb-11d9-8f82-0003933e9d82
Instance ID                     : uuid:62cfc7c4-8c48-4ae6-9b7a-5edfae850513
Format                          : application/pdf
Creator                         : Lynne
Title                           : RE040290 4208 family
Page Layout                     : SinglePage
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu