IBAC 2 â Early Warning Of Bio Aerosol Data Sheet Brochure
User Manual: IBAC-2-â-Early-Warning-of-Bio-Aerosol-Data-Sheet-Brochure
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
FLIR IBAC 2 ™ Bio-Threat Detection & Collection The FLIR IBAC 2 is a continuous, real-time air monitor that alarms in less than 60 seconds when an airborne bio-threat is present. It uses UV-Laser induced fluorescence to discriminate biological organisms from background particles, reliably detecting all four classes of biological agents at concentrations below 100 ACPLA with low false alarm rates and no consumables. The IBAC 2 system can operate independently, as part of a network configuration to form the “first tier” of a building protection system, or via battery power module for mobile detection capability. The system automatically alarms upon detection, collects and preserves samples for confirmatory analysis, and transmits data to command and control centers. From longterm, fixed installations to short, mission-based tactical applications, the IBAC 2 is the most mature and widely deployed biological trigger on the market today. CUSTOM APPLICATIONS • Building protection • Special event monitoring • Mission-based incident response • Force protection • Mass transit security FEATURES & BENEFITS • Affordable, real-time warning capability for bio-aerosol threats • Detects spores, bacteria, virus, and toxins • Autonomous 24/7 operation with no consumables • Alarm automatically triggers sample collection • Detection algorithms for indoor and outdoor use • Compact, lightweight, and rugged • Integrates with facility monitoring and control systems • US Government validated www.flir.com/IBAC2 Specifications IBAC 2 Technology UV Laser Induced Fluorescence (LIF) Sampling & Analysis Sample Introduction Sample Phase Threats Airborne particles; triggered aerosol sample collector Aerosol; flow rate 4.0 L/min (0.14 ft3/min) Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns Sensitivity Sampling & Analysis Sample Collection <100 particles/L of air Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time configurable down to 1 second Integrated with DFU or C100 sample collector (see below) System Interface Display & Alerts On-board LED for visual indication; full display via software on external computer Communication Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz) Outputs Data Storage Particle data, sensor diagnostics, bio-alarm, and fault Internal 2 GB MicroSD memory card; stores over 1 yr of data Training Requirements <2 hrs Power Input Voltage Power Consumption 100-240 VAC (adapter supplied); 18-36 VDC 20 watts (normal detector operation) 75 watts (with collector running) Battery Specs Li-ion BB 2590 military battery; up to 14 hrs runtime; charge <4 hrs Cold Start Time <5 mins Environmental Operating Temp -5 to 125 °F (-20 to 50 °C) Operating Humidity 5% to 95%, non-condensing Storage Temp -40 to 160 °F (-40 to 70 °C) Physical Features Dimensions (L x W x H) 9.5 x 6.5 x 9.0 in (24.0 x 16.5 x 22.9 cm) - without battery Weight 7.5 lbs (3.4 kg) Enclosure & Protection Aluminum, IP66 weatherproof Integrated Sample Collector Specifications Sampling Method Power Consumption Dimensions Weight Max Flow Rate DFU Collector C100 Collector Dry collection Wet or dry collection 60 watts 60 watts 3.5 x 3 in (H x Diameter) 8.9 x 7.6 cm 4.5 x 5.5 in (H x Diameter) 11.4 x 14 cm 1.3 lbs (0.6 kg) 3.0 lbs (1.4 kg) 100 L/min 200 L/min 1 to 10 microns 1 to 10 microns Collection Media Dry sampling - polyester felt filters (47mm diameter, 1 micron) Wet sampling - buffer rinse fluid provided in premeasured vials Sample Recovery Particle extraction from filter performed in vial with liquid buffer Manual liquid rinse performed at collector, yields 6mL of liquid Particle Size HEADQUARTERS FLIR Systems, Inc. 27700 SW Parkway Ave Wilsonville, OR 97070 DETECTION SALES, AMERICAS FLIR Detection, Inc. 2800 Crystal Drive, #330 Arlington, VA 22202 Phone: +1-877-692-2120 detection@flir.com DETECTION SALES, APAC FLIR Detection, Inc. 3 Pickering Street #03-49 Nankin Row Singapore - 048660 Phone: +65-6822-1596 detection@flir.com DETECTION SALES, EMEA FLIR Detection, Inc. Luxemburgstraat 2 2321 Meer Belgium Phone: +32 (0) 3665 5106 detection@flir.com www.flir.com NASDAQ: FLIR Equipment described herein may require US Government authorization for export purposes. Diversion contrary to US law is prohibited. Imagery for illustration purposes only. Specifications are subject to change without notice. ©2017 FLIR Systems, Inc. All rights reserved. 16-1695-DET Revised 01/2017 www.flir.com/IBAC2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2017:01:09 23:43:17-08:00 Metadata Date : 2017:01:09 23:43:23-08:00 Modify Date : 2017:01:09 23:43:23-08:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:94f08e48-e3a6-4f4e-951a-b2381ae9c3e2 Original Document ID : xmp.did:0180117407206811871F8133FAD11AA1 Document ID : xmp.id:06EF16EB4E206811BB8E8455690892D3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:05EF16EB4E206811BB8E8455690892D3 Derived From Document ID : xmp.did:AE1083762D206811BB8E8455690892D3 Derived From Original Document ID: xmp.did:0180117407206811871F8133FAD11AA1 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2017:01:09 23:43:17-08:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools