IBAC 2 – Early Warning Of Bio Aerosol Data Sheet Brochure

User Manual: IBAC-2-–-Early-Warning-of-Bio-Aerosol-Data-Sheet-Brochure

Open the PDF directly: View PDF PDF.
Page Count: 2

www.flir.com/IBAC2
FLIRIBAC
2
Bio-Threat Detection & Collection
The FLIR IBAC 2 is a continuous, real-time air monitor that alarms in less than 60 seconds
when an airborne bio-threat is present. It uses UV-Laser induced uorescence to discriminate
biological organisms from background particles, reliably detecting all four classes of biological
agents at concentrations below 100 ACPLA with low false alarm rates and no consumables.
The IBAC 2 system can operate independently, as part of a network conguration to form the
“rst tier” of a building protection system, or via battery power module for mobile detection
capability. The system automatically alarms upon detection, collects and preserves samples
for conrmatory analysis, and transmits data to command and control centers. From long-
term, xed installations to short, mission-based tactical applications, the IBAC 2 is the most
mature and widely deployed biological trigger on the market today.
CUSTOM APPLICATIONS
• Building protection
• Special event monitoring
• Mission-based incident response
• Force protection
• Mass transit security
FEATURES & BENEFITS
• Affordable, real-time warning capability for bio-aerosol threats
• Detects spores, bacteria, virus, and toxins
• Autonomous 24/7 operation with no consumables
• Alarm automatically triggers sample collection
• Detection algorithms for indoor and outdoor use
• Compact, lightweight, and rugged
• Integrates with facility monitoring and control systems
• US Government validated
www.flir.com/IBAC2
www.ir.com
NASDAQ: FLIR
HEADQUARTERS
FLIR Systems, Inc.
27700 SW Parkway Ave
Wilsonville, OR 97070
DETECTION SALES, AMERICAS
FLIR Detection, Inc.
2800 Crystal Drive, #330
Arlington, VA 22202
Phone: +1-877-692-2120
detection@ir.com
DETECTION SALES, APAC
FLIR Detection, Inc.
3 Pickering Street #03-49
Nankin Row
Singapore - 048660
Phone: +65-6822-1596
detection@ir.com
DETECTION SALES, EMEA
FLIR Detection, Inc.
Luxemburgstraat 2
2321 Meer
Belgium
Phone: +32 (0) 3665 5106
detection@ir.com
Specifications
IBAC 2
Technology UV Laser Induced Fluorescence (LIF)
Sampling & Analysis
Sample Introduction Airborne particles; triggered aerosol sample collector
Sample Phase Aerosol; ow rate 4.0 L/min (0.14 ft3/min)
Threats Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns
Sensitivity <100 particles/L of air
Sampling & Analysis Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time
congurable down to 1 second
Sample Collection Integrated with DFU or C100 sample collector (see below)
System Interface
Display & Alerts On-board LED for visual indication; full display via software on external computer
Communication Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz)
Outputs Particle data, sensor diagnostics, bio-alarm, and fault
Data Storage Internal 2 GB MicroSD memory card; stores over 1 yr of data
Training Requirements <2 hrs
Power
Input Voltage 100-240 VAC (adapter supplied); 18-36 VDC
Power Consumption 20 watts (normal detector operation) 75 watts (with collector running)
Battery Specs Li-ion BB 2590 military battery; up to 14 hrs runtime; charge <4 hrs
Cold Start Time <5 mins
Environmental
Operating Temp -5 to 125 °F (-20 to 50 °C)
Operating Humidity 5% to 95%, non-condensing
Storage Temp -40 to 160 °F (-40 to 70 °C)
Physical Features
Dimensions (L x W x H) 9.5 x 6.5 x 9.0 in (24.0 x 16.5 x 22.9 cm) - without battery
Weight 7.5 lbs (3.4 kg)
Enclosure & Protection Aluminum, IP66 weatherproof
Integrated Sample Collector Specifications
DFU Collector C100 Collector
Sampling Method Dry collection Wet or dry collection
Power Consumption 60 watts 60 watts
Dimensions 3.5 x 3 in (H x Diameter)
8.9 x 7.6 cm
4.5 x 5.5 in (H x Diameter)
11.4 x 14 cm
Weight 1.3 lbs (0.6 kg) 3.0 lbs (1.4 kg)
Max Flow Rate 100 L/min 200 L/min
Particle Size 1 to 10 microns 1 to 10 microns
Collection Media Dry sampling - polyester
felt lters (47mm diameter, 1 micron)
Wet sampling - buffer
rinse uid provided in pre-
measured vials
Sample Recovery Particle extraction from
lter performed in vial
with liquid buffer
Manual liquid rinse
performed at collector,
yields 6mL of liquid
Equipment described herein may require US Government authorization
for export purposes. Diversion contrary to US law is prohibited. Imagery
for illustration purposes only. Specications are subject to change
without notice. ©2017 FLIR Systems, Inc. All rights reserved. 16-1695-DET
Revised 01/2017