SUN2000 (8KTL-28KTL)

Quick Installation
Guide
0

Issue: 13
Part Number: 31505445
Date: 2015-08-03

HUAWEI TECHNOLOGIES CO., LTD.

NOTICE

1.

2.

Before you install the devices, closely read the SUN2000 (8KTL-28KTL) User Manual to get
familiar with product information and precautions. To locate the user manual, log in to
http://support.huawei.com/carrier/ and browse or search for SUN2000 on the Product
Support page.
Use insulated tools.

Inverter Model

Weight

SUN2000-8KTL/10KTL/12KTL

40 kg

SUN2000-15KTL/17KTL/20KTL/23KTL/28KTL

48 kg

1

System Installation

Determine the installation position.
Unit: mm

Install the
SUN2000 in a
position where
the liquid
crystal display
(LCD) is easy
to view and
operate.

Vertical

Backward

Forward

1

Horizontal

Upside down

Copyright © Huawei Technologies Co., Ltd. 2015. All rights
reserved.

Installing an Inverter (support-mounting is used as an example)
1.

Determine the hole positions on the support
based on rear panel dimensions.

2.

Drill holes.

4.

Mount the inverter on the rear panel.

6.

(Optional) Install an anti-theft lock.

Unit: mm

3.

Secure the rear panel.

M10 (3 PCS)
30 N·m

5.

Tighten hexagon bolts.

NOTE

1.
2.

The antitheft lock is prepared by customers.
For details about wall-mounting the device, see the
SUN2000 (8KTL-28KTL) User Manual.

2

2

Electrical Connection

1. Install a ground cable.

OT-6mm2-M6

PE terminal

NOTE

1.
2.

It is recommended that the ground cable be connected to a nearby ground position.
To enhance the corrosion resistance performance of the PE terminals, apply silica gel on them
after connecting the ground cable.

2. Install AC output power cables.
Cross-sectional Area of the Cable
(Recommended)

Inverter Model
SUN2000-8KTL/10KTL/12KTL

4.0 mm2 (12 AWG)

SUN2000-15KTL/17KTL/20KTL/23KTL/28KTL

6.0 mm2 (10 AWG) / 10.0 mm2 (8 AWG)

NOTE

The table lists only the recommended cable specifications. For more information about cable
specifications, see the SUN2000 (8KTL-28KTL) User Manual.

NOTICE

1.
2.

Do not use solid conductor hard cables.
3-core outdoor cables (L1, L2, L3) are configured for the SUN2000-28KTL and 4-core outdoor
cables (L1, L2, L3, and N) are for other models.

3

Socket

Auxiliary
connector
NOTICE

Cable sealing
cover

Large handle

screwdriver
(recommended)

The N cable is inserted into hole 4. Do
not insert L1/L2/L3 into
.

Notch

Click

NOTE

To quickly connect the AC output connector to the AC
output terminal of the inverter, keep the notch of the
connector facing exactly to the operator.

NOTICE

Ensure that the AC output connector is securely connected. Otherwise, the connector may be
damaged after the inverter has been running for a long time.

3.

Install DC input power cables.

Optional DC input terminals:

Number of
Inputs

8KTL-12KTL

15KTL-28KTL

1

Connects to any one
route

Connects to any one route

2

Connects to routes 1
and 3

Connects to routes 1 and 3

3

Connects to routes 1,
2, and 3

Connects to routes 1, 3, and 5

4

Connects to routes 1,
2, 3, and 4

Connects to routes 1, 2, 3, and
5

N/A

Connects to routes 1, 2, 3, 4,
and 5

N/A

Connects to routes 1, 2, 3, 4, 5,
and 6

5
6

4

Positive and negative metal terminals:
Positive metal terminal (female)
Negative metal terminal (male)

Positive metal terminals

Negative metal terminals
Common PV cables with a crosssectional area of 4 mm²in the
industry are recommended.

Recommended: H4TC0001
(Amphenol)
Ensure that cables cannot
be removed after crimped.

Positive connector

The skid automatically
starts after the ejector
lever is fastened.

Negative
connector
Click

Recommended: H4TW0001
(Amphenol)

NOTICE

1.

Pull back the DC input power cables to check whether the cables would be disconnected.

2.

If DC input power cables are reversely connected and the DC switch is ON, do not turn off
the DC switch immediately. Otherwise, the equipment may be damaged. You can
disconnect the DC input power cable on the PV string side or wait until the PV string
voltage reduces to a value within the safety range. Then, turn off the DC switch, remove
the positive and negative connectors, and rectify the connection.

5

4.

Install an RS485 communications cable.
No.

The side without buckles

RS485A, and RS485
differential signal+

Orange

RS485B, and RS485
differential signal-

White and green

PGND

Blue

RS485A, and RS485
differential signal+

White and blue

RS485B, and RS485
differential signal-

6

Green

PGND

7

White and brown

PGND

8

Brown

PGND

2
3
4
5

3

Pin Definition

White and
orange

1
RJ45
Matching nut
connector
Sealing
with
Plastic
washer
shielding base
functions
Cable
sealing nut

Color

Installation Verification

1.

Check that all screws, especially the screws used for electrical connections,
Passed □ Failed □
are secured.

2.

Check that all circuit breakers are switched to OFF.

Passed □ Failed □

3.

Check that the ground cable is securely connected and no short circuit
occurs.

Passed □ Failed □

4.

Check that AC output power cables are connected correctly and securely
(the N wire is connected to hole 4, and L1/L2/L3 can be connected to any
hole of 1/2/3; for details, see 2.2 Install AC output power cables), with no
short circuit.

Passed □ Failed □

5.

Check that DC input power cables are connected correctly and securely,
with no short circuit.

Passed □ Failed □

6.

Ensure that idle DC input terminals are sealed.

Passed □ Failed □

7.

Check that the idle USB and RS485 ports are plugged with waterproof
plugs.

Passed □ Failed □

4

System Power-on

1.
2.
3.

Switch on the AC circuit breaker between the SUN2000 and the power grid.
Ensure that the DC Switch at the bottom of the SUN2000 is ON.
(Optional) Measure the temperatures at the joints between the DC terminals and the connectors.

5

Setting Monitoring Parameters

1.

2.

If no data collector is used, set the following parameters before connecting the SUN2000 to the
power grid. For the other parameter settings, see the SUN2000 (8KTL-28KTL) User Manual. If
a data collector is used, see the SmartLogger1000 User Manual for the parameter settings.
The preset password for Common User, Advanced User, and Special User is 000001. Use
the preset password to log in to the SUN2000 for the first time and then change the password
to a new one to ensure the account security.

6

Main
Menu
Wizard

SecondThird-Level
Level Menu
Menu

Fourth-Level Menu

Setting

Language

-

-

Set based on site requirements.

Date&Time

Date

-

Set based on site requirements.

Time

-

Set based on site requirements.

-

-

China medium-voltage power grid,
choose CHINA-MV480.

Grid Code

China low-voltage power grid,
choose NB/T 32004.
For other cases, see the Appendix.
Main Menu Settings

Isolation(Ad Input Grounded, With When the PV- is grounded, an
vanced User) TF
isolation transformer should be
connected. Set Isolation to Input
Input Ungrounded,
Grounded, With TF.
Without TF
Input Ungrounded,
With TF

7

When the PV- is not grounded, set
Isolation to Input Ungrounded,
Without TF or Input Ungrounded,
With TF.

Appendix: Power Grid Standard Code Mapping Table
No.

Power Grid
Standard Code

Country and Condition

No.

Power Grid
Standard Code

Country and Condition

1

CHINA-MV480

China medium-voltage
power grid

24

IEC61727MV480

IEC medium-voltage power
grid

2

NB/T 32004

China low-voltage power
grid

25

VDE 0126-1-1BU

Bulgaria low-voltage power
grid

3

UTE C 15-7121(A)

France low-voltage power
grid

26

VDE-AR-N-4105

Germany low-voltage power
grid

4

UTE C 15-7121(B)

Islands of France 230 V
50 Hz

27

BDEW-MV480

Germany medium-voltage
power grid

5

UTE C 15-7121(C)

Islands of France 230 V
60 Hz

28

BDEW-MV

Germany medium-voltage
power grid (400 V AC)

6

UTE C 15-7121-MV480

France medium-voltage
power grid

29

TAI-PEA

Thailand low-voltage power
grid (PEA)

7

G59-EnglandMV480

UK 480 V Medium-voltage
power grid (I > 16 A)

30

TAI-MEA

Thailand low-voltage power
grid (MEA)

8

G59-England

England 230 V
power grid (I > 16 A)

31

TAI-PEA-MV480

Thailand medium-voltage
power grid (PEA)

9

G59-Scotland

Scotland 240 V
power grid (I > 16 A)

32

TAI-MEA-MV480

Thailand medium-voltage
power grid (MEA)

10

G83-England

England 230 V
power grid (I < 16 A)

33

EN 50438-DK

Denmark medium-voltage
power grid

11

G83-Scotland

Scotland 240 V
power grid (I < 16 A)

34

Japan(50Hz)

Japan power grid (50 Hz)

12

CEI0-21

Italian low-voltage power
grid

35

Japan(60Hz)

Japan power grid (60 Hz)

13

CEI0-16

Italian medium-voltage
power grid

36

EN50438-TRMV480

Turkey medium-voltage
power grid

14

IEC61727

IEC low-voltage power grid

37

EN50438-TR

Turkey low-voltage power
grid

15

VDE 0126-1-1GR(A)

Mainland of Greece lowvoltage power grid

38

C10/11

Belgium low-voltage power
grid

16

VDE 0126-1-1GR(B)

Islands of Greece lowvoltage power grid

39

C11/C10-MV480

Belgium medium-voltage
power grid

17

EN50438-CZ

Czech Republic lowvoltage power grid

40

Philippines

Philippines low-voltage
power grid

18

RD1699

Spanish low-voltage power
grid (Pn < 100 kW)

41

PhilippinesMV480

Philippines medium-voltage
power grid

19

RD661

Spanish low-voltage power
grid (Pn > 100 kW)

42

EN50438-NL

Netherlands low-voltage
power grid

20

AS4777

Australia low-voltage
power grid

43

Custom(50Hz)

Reserved

21

AS4777-MV480

Australia medium-voltage
power grid

44

Custom(60Hz)

Reserved

22

NRS-097-2-1

South Africa low-voltage
power grid

45

Custom-MV480
(50Hz)

Reserved

23

NRS-097-2-1MV480

South Africa mediumvoltage power grid

46

Custom-MV480
(60Hz)

Reserved

NOTE

Grid codes are subject to change. The listed codes are for your reference only.

8

HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base Bantian Longgang
Shenzhen 518129
People's Republic of China
www.huawei.com
9



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 10
Language                        : zh-CN
Producer                        : Microsoft® Office PowerPoint® 2007
Creator                         : Microsoft® Office PowerPoint® 2007
Create Date                     : 2015:08:03 18:32:01+08:00
Modify Date                     : 2015:08:03 18:32:01+08:00
EXIF Metadata provided by EXIF.tools

Navigation menu